HomeMy WebLinkAboutPermit MI97-0130 - LEWIS AND CLARK BOWLING - REROOF1
AND
(5DW I
013
City of Tukwila - •
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MISCELLANEOUS PERMIT
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES,
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No: 222304 -9015
Address: 15820 PACIFIC HY S
Suite No:
Location:
Category: NSFR
Type: MISCPERM
Zoning: RC
Const Type:
Gas /Elec.:
Units: 001
Setbacks: North:
Water: 125
Wetlands:
Permit No:
Status:
Issued:
Expires:
MI97 -0130
ISSUED
08/12/1997
02/08/1998
Occupancy: BOWLING ALLEY
UBC: 1994
Fire Protection:
.0 South: .0 East: .0 West: .0
Sewer: VAL.VUE
Slopes: Y Streams:
Contractor License No: ACKERRC099MA
OCCUPANT
OWNER
CONTRACTOR
CONTACT
LEWIS AND CLARK BOWLING
15820 'PACIFIC HY S, TUKWILA WA 98168
STERLING RECREATION ORG
PO BOX 91723, BELLEVUE.WA 98009
ACKER ROOFING CO INC
12704 217 SE; SNOHOMISH WA 98290
KEN ACKER
Phone :.(206)455 -8100
Phone: 425.486 -3968
Phone: '425 -486 -3968
PO BOX 69, WOODINVILLE WA 98072
****************•*** * * * * * * * * * * * * * * * *k * * * * * * * *k * *•k* Irk****• k * * * * * * * * * * * * * * * * *•k * * *•k * *k *•k*
Permit Description:
APPLY U.L. CLASS B RATED ROOF MEMBRANE OVER
EXISTING ROOF.
******************** k************* k************** k***** *•k * * * * * * * * * *k * * * *•k * * * * * * * * *k*
Construction Valuation:, $ 85,765.00
PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr:
Curb Cut /Access /Sidewalk /CSS: N
Fire Loop. Hydrant: N No: Size(in): .00
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Cut: Fill:
Landscape Irrigation: N
Moving Oversized Load: N Start Time: End Time:
Sanitary Side Sewer: N No:
Sewer Main Extension: N Private:
Storm Drainage: N
Street Use: N
Water Main Extension: N Private: Public:
***************************************** k************• * * * * * *k *k* *• * * * * * * ** ** * *** * **k*
TOTAL DEVELOPMENT PERMIT FEES: $ 804.25
*****•**********************************•* k**•**** k• k****** *•k * * *k * * * * * *k * * *•k * * * * * * * * * *kk
Public:
Permit Center Authorized Signature:
Date:__ I1 jq7
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the provision of any other state or local laws regulating construction
or the performance of work. I am authorized to sign for and obtain this
development permit.
Signature:
Print Name : icewAi 7 /4, /hr/14-0A-
Date: P %/Z197
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
Address: ''15820. PACIFIC
Suite
Tenant: ,Status ISSUED'.
Type'. .MISCPERM Applied: 08/12/1997'
Parcel #: 222304 -9015 Issued: 08/12/1997.':
*******' k****;• k*************' k**,*****.**' k*****• k' k*** *. * * * * * ** * **'k * * ** "k* **'k'k ** ** k. *:
Permit- Conditions:
No changes will be made to the plans unless approved by the.
Arch.i'tect or Engineer and the.,.Tukwi l.a_'. Bu;i i di ng Division.
• All permits, inspection reco'r,'ds,'` and ,approved plans shall be
available at the j,ob {site pfTior to the ::start ,pt any con-
atruction. These }c tcuments ,are to 'be maintained and avail-
able until final.,,inspecet'1on :;approval is granted`.:x
• All constructlonf to be 'done in°Aconformance with apprao,ved
plans and , 0• quiremenof the Uniform Bui'ldi'ng ,Code 94
Edition) ,-AS! ,?amended '''
Val i dl ty o'f Permit ,". J4The r issuance of a Permit or approval of
plans, s;pecif teat ions', and c:omp.uta,t„ions shall , not.be;..,,con
strrueleto ;be a per;rnit for'; ror an approval of, any` viulati:on.,
of ar� y of >the provisions. of.the building code or. of any,
othe#�' ardith nce ,..of the jur i sdi,c.t�ion. No permit presuming
give're'uthority .to violate or,t,cancel;:the provisions of. this
.code shall ` be .Val i d .
CITY OF TIIKWILA
Permit Center (.
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Miscellaneous Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
Project Name/Tenant:
L6w5 d- &L4/L. t3vi/AJO
Value of
Construction:
6S, 4b
Site Address:
P' ft . 3ioIN,s,
City State /Zip:
S, j igi.44,4,1, ,
Tax P,,wcel Number.:, 1 B
a 0),;---3r) Li — �
Property Owner:
37-6/A/6 Ab ry
ofe6
/ z/977O
Phone:
�Hz 0 y Sf - g/ 6S
Street Address:
p, o, g,� 7 / 7 2)
City State/Zi •
8 eLce ,}v', . ,� 9
Fax #:
0 Water
Contact Person:
,'rev Ac-/z-64-
Phone:
(/25)
Fax #:
y25)
yeG -3966
/-/P/ - 96 5?
Street Address:
/a Bra 6
City State/Zip: :
woonotivlt t,6- ti . 9'�1.
Contractor:
Ac/.e -e/t- /2- GaPiAle,
CPI /4AI j` 41.14-1
Phone: }
(gZS,1 y N -2 e
Street Address:
Oro, tW 62
City State/Zip:
Iv000 /�v/Lt -el, r'. ,0 A,
Fax #:
� 252
y� /�9G,�%
Architect: N QN&
Phone:
Street Address:
City State /Zip:
Fax #:
Engineer:
MQNGt`
Phone:
Street Address:
City State /Zip:
Fax #:
MISCELLANEOUS PERMIT REVIEW AND 'APPROVAL REQUESTED: 0 BE FILLED OUT BY,. "APPLICANT)
Description of work to be done:
/If /)& U- L, 61f9 /3 11-q1�" /LG'/. Al e/16/1-- 'lit Dc%`x c`r#77,i.'6
Will there be storage of flammable /combustible hazardous material In the building? ❑ yes ® no
list of materials and stora e location on separate 8 1/2 X 11 a er indicatln.. uantities & Material Safet Day to Sheets
-Attach
Ll Above Ground Tanks tJ Antennas /Satellite Dishes Bulkhead/Docks Fri Commercial Reroof
❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only
❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems
❑ Temporary Facilities ❑ Tree Cutting
APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS;
Channolization /Striping
❑ Flood Control Zone ❑
❑ Landscape Irrigation ❑
❑ Storm Drainage ❑
❑ Water Meter /Exempt #
❑ Water Meter /Permanent #
❑ Water Meter Temp #
❑ Miscellaneous_
tJ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s):
Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing
Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
Street Use ❑ Water Main Extension 0 Private 0 Public
0 Deduct 0 Water Only
Size(s):
Size(s):
Sizes Est. quantity: gal Schedule:
: ID Moving Oversized Load/Hauling
MONTHLY SERVICE BILLINGS TO::
Name:
Phone:
Address:
City /State /Zip:
0 Water
0 Sewer
0 Metro
0 Standby
WATER METER DEPOSIT /REFUND BILLING:
Name:
Phone:
Address:
City/State/Zip:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Permit Center to comply with current foe schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
Date application afcepted: Date application expires: App 'cation taken by: (initials)
)(s2.- q7 11211Sy -- -w
l
ALL MISCELLANEOUS P 'MIT APPLICATIONS MUST BE SUB' TED WITH THE FOLLOWING:
➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
➢ CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
rl ❑
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR
Above Ground :Tanks/WaterTanks - Supported directly upon grade
exceeding 5,000 gallons and a ratio of height to diameter or width
which exceeds 2:1
PERMIT REVIEW
Submit checklist No: M -9
❑
Antennas /Satellite Dishes
Submit checklist' No "M -1
❑
Awnings /Canopies - No signage
Commercial Tenant Improvement
Permit
❑
Bulkhead/Dock
Submit checklist No: M -10
El
Commercial Reroof
Submit checklist" No: M -6
❑
Demolition
Submit checklist ":. No M -3, . M -3a
❑
Fences - Over 6 feet in Height
Submit checklist No: M -9
❑
Land Altering/Grading/Preloads
Submit checklist No: M -2
Q
Loading Docks
Commercial Tenant Improvement
Permit. Submit checklist No: H -17
0
Mechanical (Residential :& Commercial)
Submit checklist No M -8,
Residential only - H -6, H -16
❑
Miscellaneous PubIIc Works Permits
Submit checklist No H =9
❑
Manufactured `Housing :(RED INSIGNIA ONLY) "
Submit checklist No: M -5
❑
Moving Oversized"Load/Hauling
Submit checklist No: "M -5
❑
Parking Lots
Submit checklist No: M -4
❑
Residential Reroof - Exempt with following exception: If roof structure
to be repaired or replaced
Residential Building Permit
Submit checklist No: M -6
❑
Retaining Walls - Over 4 feet in height
Submit checklist No: M -1
❑
Temporary Facilities
Submit checklist No: M -7
0
Temporary Pedestrian Protection/Exit Systems " ,
Submit checklist No: M -4
❑
Tree Cutting
Submit checklist No: M -2
❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
Building :Owner /Authorized Agent. If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: ,--,,,,,,,,A -,, t----
Date: 9 /1 L/ 9 7
Print name: )4.E. /Nt;i-7'I
fl .
/30, --
71-
C.v.✓l
-
r 2-
Phone: 106 .7 96
City /State /Zip:
Fax Fax #: ygi -
,`9
' 2;
Address:
19�(} �,
0.
MISCPMT.DOC 7/11/96
^'A ', RA t+
**A•h ***k, * *, * * * * **•k * *kkkk ** * * *• • * *k * * * *+k * **•k * * *•k**k*`k
ITY OF 1'UKWILH, WA 9 1 TRANSMIT
* "kkk * * * *k k *k* * ** * * *** ** k * **h hh *� k ** * * * **A ** h *A * **k*k*
T'RANBMIT Number,': R9700626 Amount 804..2 08/12/97 09:45
Nayrelt'Metthodr CHEC.I( Notation: AMER R00FING Initr Kf7N:.
permit No MI97-0130 Type: M,ISCRERM MISCE4LANEOUS PERMIT.
Parcel Noa., 222304- 90i5
Site,;Addree4; 15820 PACIFIC HY S
Total Fes: 804.25
Total ALLL Pmtai '804.25
Balance: AO'
k********•**•*********** •**'k* *:**h **** * * ** * ***** *AAA*. **: **,tiA1r1 * **
Account Code
000/322.,100
000/386 ..904
'Description
,BUILDINO - RES
S,TAT;1: ,BUILDING SURCHARGE
Amount
799.75'
.4. �0..
IrtY
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
wewsovenwinilistrAirlr
PERMIT NO.
(206) 431 -3670
Mt:• .. '
,ins • ectio .
'••red: _ �. .
•.
(pRecial instructions:
C".....CLIL01., - C; -C�QS
a w: nted:
•
"
quester:
ue
' 0
-i
1 _..)\^,...g,r -% Qym Lteu.A.
It . lira 4 ..
h . No.:
�- '
,rlr
Ail
Approved per applicable codes.
Corrections required prior to approval.
Inspector:
Date(�
x
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPEC •N NO
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
N1:
f r a'Y +LX::.;la4kg.( •,'tre. 4.04 4:41,
INSPECTION RECORD
Retain a copy with permit
JE2O. '
Da t 206 431 -36 0
Project:
IN-f
Typ= of insg�ction:
• r f - 1� ( r
A d c
Date called: 2 I
Specia instruction
ti
. _ ... ._.
Date wanted:
Requestere� a er
i. Nx35 I , 1 _____, 0 n . ,
Appfoved per applicable codes.
Corrections required prior to approval.
MENTS:
Inspector:
Gl.
���
1-1 $42.00 REINSPECTI • N FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection.
ACKERRC099MA
AC ER ROOFING CO PANY, INC.���� (17.019 P.O. Box 69 • Woodinville, Washington 98072
(206) 486-3968
September 15, 1997
City of Tukwila
Community Development /Public Works
6300 Southcenter Boulevard, Suite 100
Tukwila, Wa. 98199
Re : Lewis and Clark Lanes
15820 Pacific Highway South
Tukwila, Wa.
Building Permit # MI97 -0130; Reroofing
To whom it may concern :
Acker Roofing Company, Inc. completed the above referenced project on
September 12, 1997.
All work was performed in compliance. to the proposal letter sent to the owner
and submitted to the City of Tukwila, dated January 21, 1997.
This project was inspected by Durolast Roofing ( membrane manufacturer) on
September 12, 1997. The work was certified warrantable by Durolast, and a 15
year warranty was issued; , o � N4'rr u..eD rd a_ A C�.�BS ,a ,2,x714 ,.
9
Sincerely,
Acker Roofing Company, Inc.
Kenneth M. Acker, President
6100 i•55SOUTH • S?5N01118YDR. 1160 KW. VINE ST.
3ACXSON,19 36111 SAGOIAW, ML 41601 GRANTS PASS, 01197526
1400.4.114t76 - 1.100.361010 14001566646
PAX 1400366411 FAX 14004326331 PAX 1.004661696
Duro -Last Membrane(s)
Nslaw
AST3 D•7S1
.010 tall mmlml
•
34m
Tom m os&
AS116 D.751
Thom settod
rxroroplo
1306x 1106
SON x490N
Amides mph
AGM D•751
435 /x 3506
1933N•1557N
11■06AQUA
Papxn
AST14 B931
Dom SYo
a6.1MSllao
156,307 MI,e
1Cmetdm
ASTAI D•751
2191
1711
Dkomrfmal Stol aky
AGIN D•1101
vP Chow
.4,311 Chop
Low worpor mo
Oodbab
AIM D•3136
1lrldxobxi
m, aub
•40P
No ands
40C
Dymeb Wpm
(Naomi*)
Si ad.10111
kbikod i
2509
1112N '
W. ■p
7 osonloim
ASTM 1116 WVE
Prooedorx 11
Modoxl A
<30 US Pam
0.017 er/orpo
0AS709011
AoodwYd wn/imbs
Cuba Aro
6000 b
No aub, canna or bl4emky
A_.. ..2Wrokmlos
1TVS•313 Lamp GPO C
A3fl40•SSp
1000 b
Noaulot, anima, bli r,
Foray Ghoul Rum*
ASTM 13.101
C4m 1 1.60 • 1.90
UJ....tirmLa►axtay
•
114790
Mrs •A.RORC
Duro -Last Membrane (available in white,
gray and tan colors) is fabricated from a
high tenacity, low shrink weft inserted
18 x 14, 1000/Denier polyester fabric that
has been coated with a proven thermoplas-
tic alloy. This specially formulated perma-
nent thermoplastic alloy does not have
conventional plasticizers that migrate from
the coating. It is resistant to ultra- violet
rays and micro - organisms. The tear and
puncture strength of the polyester fabric
are superb, and it is impervious to most
caustic chemicals, petroleum products, ani-
mal fats and acids. It shows no ill effects
from either extreme heat or cold.
The Duro -Last Membrane is non - curing to
provide excellent weldability for the entire
life of the system. A patch, curb, stack or
any other necessary additions or alter-
ations can easily be accomplished by heat
welding the new Duro -Last membrane/
accessory to the existing membrane. Heat
(hot air) welding is used to bond all field
seams. The welds can be made with a hand
held unit or a walker welder. The hot air
seaming eliminates the need for chemicals,
torches and other unsafe, non - manageable
seaming systems.
Note: All components of the Duro -Last Roofing System shall be products of Duro -Last, Inc.
Substitutes must have nor acce 1 tance b Duro -Last Inc.
•
•
•
g9 Inc,
oofing System
SPECIFICATION
. • • •
GINEER VCONTRACTORS AND OWNERS
ET.RO=DADE
• ,
Metrop011tan Dade County, Florida
17.•• Approved
.., •
1 v ,,,,:,,•;t..: , , ' •
r 4 1
Aili 40' •
•< ',.• ,
.,1
eb
m'
sefi
,...-
/,..,.,
e
ve '
If, 0, • • 4
a.
• ,• .:. .. ' ',,
. , 4 eVt',:•,.,
Copyiight4,0-1982,. 1983; 1984,1985, 1986, 1987, 1988, 1989,
— ,....1,,--,'W.V.IP'44';`,/;.. ti,...,•4. !'J.-, , • ',
1990;199119921993 1994, 1995
..,,.,,;,,..:,0,)3..,?,,..oi - -,'
By Duro-Last,. Roofing, Inc.,
'THE STANDARD CODES"
All Rights Reserved
Printed In United States of America
ICBO
N ER -227
IbURO-
Iii•AST®
Roofing, Inc.
525 Morley Drive
Saginaw, MI 48601
lf
MAINTENANCE AND REPAIR
CLASS: B
1. Deck: C -15/32 (12mm) Incline: 1 (1 :12)
Existing Roof System: Class B BUR system smooth
surfaced covered with:
Slip Sheet:
a) Type 30 or Type G2 (451b) base sheet
b) 1 layer Lydall Manning Div. 10 mil (.25mm)
" Manniglas 1200"
c) 1 layers of Atlas Energy Products "FR10" mechan-
ically fastened.
d) AMOCO Foam Products Co. "Amocor P14, PB4,
PB6
Carpenter Insulation Co "Foamfold"
Minimum 1/2 inch (13mm) wood fiber roof insu-
lation
g) 3 mil (.08mm) polyethylene film (not UL classi-
fied).
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
e)
0
2. Deck: C -15/32 (12mm) Incline: No Limitations
Base Sheet: One layer of Type G2 OCF base sheet,
mechanically fastened to the deck.
Cap Sheet: One layer of Type G3 GAF Mineral
Surfaced Cap Sheet, hot mopped.
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
Coating: Kool Seal "Unifies" Elastomeric White,
Gray or Black roof coating at 3/4 to 1 gal/sq. (.31/m2)
Surfacing: No. 11 roofing granules embedded in the
wet coating at 50 lb /sq. (2.5 Kg/m2).
3. Deck: C -15/32 (12mm) Incline: No Limitations
Existing Roof System:
a) Class A, B, orCmineralor smooth surfaced asphalt
felt roofing system, covered with:
b) Single -ply (modified bitumen) roof system, cov-
ered with:
c) Class A, B or C asphalt organic felt or glass fiber
mat shingles, covered with:
Slip Sheet: 2 layers of Atlas Energy Products "FR10"
mechanically fastened.
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
Class A, B, or C.
1. Deck: C -15/32 (12mm) Incline: 2 (1:6)
Existing Roof System: Class A, B, or C, classifica-
tion will be retained , covered with:
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
NEW CONSTRUCTION
MECHANICALLY FASTENED
CLASS: A
1.
Deck: C -15/32 (12mm) Incline: 3 (1 :4)
Barrier Board: Gypsum, 1/2 inch minimum, joint
offset 6 inches from joints in the deck, mechanically
fastened.
Insulation: (Optional)
a) Any UL classified polystyrene insulation (tapered
or uniform thickness) any thickness covered with 1
inch (2Smm) perlite, 1 inch (25mm) wood fiber.
b) Celotex "Star AP" or " Hy -Tec ", any thickness.
c) Atlas Energy Products "ACFoam I" or "ACFoam
II" any thickness.
d) OCF "Roof Deck Boards"
e) Wood fiber
0 Perlite 1 -1/2 to 3 inches
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
2. Deck: NC
Insulation: (Optional)
Any UL classified polystyrene insulation (tapered
or uniform thickness) any thickness covered with 1
inch perlite, 1 inch wood fiber, Lydall Manning
Div. 20 mil (.5mm) "Manniglas 1200" or Atlas
Energy Products "FR10"
Celotex "Star AP" or " Hy -Tec ", any thickness.
Atlas Energy Products "AC Foam I" or "AC Foam
II", any thickness,
d) OCF "Roof Deck Boards"
e) Wood fiber
0 Perlite 1 -1/2 to 3 inches (38 to 76 mm)
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
Incline: 3 (1:4)
a)
b)
c)
3. Deck: C -15/32 (12mm) Incline: 2 (1 :6)
Slip Sheet: Layer Lydall Manning Div. "Manniglas
1200 ", 15 mil (min) (.38mm /min).
Insulation: Two layers 3/4 in. (19mm) perlite, joints
staggered 16 in. (.4 m), mechanically fastened.
Membrane: "Duro- Last" (PVC), mechanically fas-
tened.
4. Deck: C -15/32 (12mm) Incline: 3/4 (1:16)
Slip Sheet: 2 layers of Atlas Energy Products "FR10"
mechanically fastened.
Insulation : Glass fiber or Perlite,
Atlas Energy Products "AC Foam I" or "AC Foam II ",
R -Max "Multi- Max ",
NRG Barriers "E'NRG'Y I ",
Celotex "Star AP ", "Hy -Tec ", "Hy -Therm AP" or
6 CODES
DLSPEC•REV 5/95
ACkt"R ROOFING COMPANY, INC.
C
P.O. Box 69 • Woodinville, Washington 98072
(206) 486 -3968
ACKERRC099MA
Sterling Realty Organization
P. O. Box 91723
Bellevue, Washington 98009 -1723
January 21, 1997
Attention : Ivar Parks
Reference : Lewis and Clark Lanes, 15820 Pacific Highway South, Tukwila, Wa.
Subject : Reroofing (barrel roof and adjacent roof to the north and south)
Dear Ivar,
We have prepared for your review the following proposal and price quote for performing
the above referenced work.
As we said in our letter dated March 1, 1995, the existing roof on the barrel is composed
of a tongue and groove roof deck, covered by 1" of wood fiber insulation, covered by a
smooth surfaced built -up asphalt roof membrane. The adjacent flat roofs are composed of
a concrete roof deck, covered by 1" of wood fiber insulation, covered by a gravel surfaced
built -up asphalt roof membrane. Some of these roofs have received spray coatings since
the original application. All have only 1 thickness of built -up asphalt roof membrane
existing now.
Since the existing roofing is only 1 layer deep and the roof decks are, to the best of our
knowledge, in sound condition, it is appropriate and in code compliance to simply roof
over the existing roofing.
We are proposing to reroof these roofs with .037 mil thick PVC membrane roofing
manufactured by Durolast Roofing, Inc. The system we are proposing is very lightweight,
very attractive (white), extremely durable, and is warranted by the manufacturer for 15
years after application. We have enclosed for your review, manufacturer's literature.
The following is our proposal and price quote:
• The roofs will be cleaned of loose gravel, water, and debris. These materials will be
removed and disposed of in a legal manner.
• All metal copings will be removed and saved for reuse.
• 3" holes will be cored through the walls adjacent to the existing roof drains for
installation of overflow scuppers. Without overflows, these roofs are not in
compliance to current codes.
(1of2)
ACKERRC099MA
•
ACka ROOFING COMPANY, INC.
P.O. Box 69 • Woodinville, Washington 98072
(206) 486 -3968
The barrel .roof will be covered with 2 plies of "FR -10" slipsheet to be in compliance
with U. L. Class B fire rating and to buffer the new membrane from the old.
• The flat roofs will be covered a 1/2" rigid insulation board to buffer the new
membrane from the old. This application is in compliance to U. L. Class B fire rating.
• The new substrate coverings on the roofs will be covered with .037 mil "Durolast"
membrane, applied in strict compliance to manufacturer's application specifications,
using manufactorer's accessories. All membrane will be mechanically fastened in
compliance to Factory Mutual I -60 standards. All seams will be hot air heat welded
per manufacturers standards.
• All previously cored overflow holes willreceive scupper liners.
• The hardware at all roof drains will be reused or replaced as necessary to provide
clamping ring drains with strainers.
• All previously removed sheet metal will be reinstalled.
• All roofing and cleanup will be performed in a thoroughly workmanshiplike manner.
• After completion, a representative of the membrane manufacturer will inspect the roof
pursuant to issuing a 15 year warranty.
• After completion and inspection, a 15 year warranty will be issued by Durolast
Roofing, Inc.
We will furnish all equipment, labor, materials, and permits to complete the previously
described work for the price of $4276L99. This quote does not include sales tax.
SS76S.00
If you would like us to perform the previously described work, please sign where indicated
and return a copy to us.
Thank you for this opportunity to be of service.
Accepted By
Very Truly Yours,
Acker Roofing Company, Inc.
Kenneth M. Acker, President
Date g4 Z 5/0
(2of2)
j— DETACdi TO DISPLAY CERTIFICATE -
DEPARTMENT OF LABOR AND INDUSTRIES
THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
9807'2
•
STATE OF
WASHINGTON
Gal
it
STATE OF WASHINGTON :I
L DETACH TO DISPLAY CERTIFICATE .J
REGISTRATIONS AND LICENSES
ia•
F625. 052.000 (3.92) ;'i 1
UNIFIED BUSINESS ID #: 601 321 263
BUSINESS ID #: 001
ORGANIZATION TYPE
DOMESTIC PROFIT CORPORATION
ACKER ROOFING COMPANY INC.
12704 217TH SE
SNOHOMISH WA 98290'
DOMESTIC PROFIT CORPORATION
RENEWED BY AUTHORITY OF SECRETARY OF STATE
The above entity has been Issued the business registrations or licenses listed
DEPARTMENT OF UCENSINO, BUSINESS 1 PROFESSIONS DIVISION,
P.O. BOX 9034 OLYMPIA, VIN 96501.9031 (206) 7534401
0002511 79
EXPIRES : 05 -31 -1995
artmant of anOE any