Loading...
HomeMy WebLinkAboutPermit MI98-0101 - HALLWOOD MANAGEMENT COMPANY - REROOFHALLWOOD. MANAGEMENT REROOF BLDG 2 MI98-0101 City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 022340 -0030 Address: 500 INDUSTRY DR Suite No: Location: BUILDING #2 Category: NSFR Type: MISCPERM Zoning: TUC Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: .0 South: .0 E Sewer: N/A Slopes: N Contractor License No: HAIGHRC269QK OCCUPANT OWNER CONTRACTOR. CONTACT Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: ast: .0 West: HALLWOOD MANAGEMENT COMPANY 500 INDUSTRY DR, TUKWILA WA 98188 SBP GENERAL PARTNERSHIP 617 INDUSTRY DR, TUKWILA WA 98188 HAIGHT ROOFING COMPANY INC. P.O. BOX 70150, SEATTLE, WA 98107 DOUG MILLETT 617 INDUSTRY DR, TUKWILA WA 98188 ****************************************************** ** * * * * *** * * * * * * * * * * * **•k * * *•k ** Permit Description: TEAR OFF EXISTING ROOF DOWN TO DECK AND INSTALL A NEW BUILT -UP ASPHALT ROOF. k*************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 60,562.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: ***************************************************** * * * * * * * * * * * * * * * * * * * * * *•k * * * * * ** Streams: MI98 -0101 ISSUED 09/03/1998 03/02/1999 OFFICE 1994 .0 Phone: 206 784 -8414 Phone: 206 -575 -6675 Size(in): .00 End Time: Fill: ls( _��• TOTAL DEVELOPMENT PERMIT FEES: $ ******* * * * * * ** * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ 648.00 * * * * * * * * *k* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date: 91 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the • •v .ion of any other state or local laws regulating construction or the pe orman'e of w rk. I am authorized to sign for and obtain this development permit. Signature Print Name:_ ' ► /r" Date a __a __ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. (1) CITY OF TUKWILA •,.- • ,. ,,' ' I. , , ,.i:.,.. .•=.'.. ' ('''''! . '''I:i.:;si,,„.10 ". •• 1- ;,,,1 •.,..., ''''''%. '-:'•.:.--.-ir,;,...;.•...,......:., . •• ....,;? :'' 1 ` c....; •:. ',..• '''' / \ i‘ "•.:■, ' '''''ir''''''. ...";, . ' . -.,,:, -':::,), .., r:t „ • , ', -i'••,•, , i 3 (.' 'A . 1 : '''.'•!. „:•;''' , ; . . C i ee■',A.,'■•i''''';;: : ' • •,,. ':'s• • • : • " . • • • iA t IS% Li'•4••'i • .1, . • •4, 4 • CITY OF TUKWILA REROOF CONDITIONS Permit No: MI98-0101 Project Name: HALLWOOD MANAGEMENT COMPANY Address: 500 INDUSTRY DR Suite: • THE FOLLOWING CONDITIONS WILL APPLY TO RE-ROOF pERMITS:. 1 All re-TOOfincLotoJects will be accomOitieIY.in compliance with Appendi/Chapter15 of .the Uniform .Buildin“ode .(11BC): 2.: InspectiOnS:„ .. ,..,:,,. Ai'.'New,roof cOverings'Sfiall no be applied 44thout,;-firSt . . Obtaining :a pre-:roofing inspection from the4BOldingn Dt.vi'SIOn:and written approval -from the BuilqingAWspeCtor. The pre-rooting 'InspeCtion shall pay particular .attention to evidence of actilMulatlfon of water -Where extensive potting of water isfapparent,an„analysis_ofthe roofstruicitur;e\lor compliance -with sect;:fOn A5M Oc, shall be madeapd ,-, corrective meas6res.;.:Such as 'relocation of roof dratnstir, sotiOpers,°resloO.ing:Off;theobf-'6r struturall:.ohaiigii,senSball t,. be'accompliShed.; An-JkspectiOn.,coVering the above.;liste'd topics 'prepaed. 6y-4 qualified speclal inspector, a'S In deterMined by the Buildini':Official-may be accepted ',in lieu of'the-pre-inspection by the'Bullding InSpector, ....', . , „ B',';,A final inSpection and approyal/Spall,,be pbtained.fropy the .,. ."'*ilding DiOsioniNhen the re-rbofingjsomplete.,,,,4s a c01clitiOn,.of 'the final inspection fC0 .rObfsthat Me*Uire a fire retardant roof covering under he prOP4.:F.lon$01 Table 15-A. 1994 the root instatler'Shall kOVidethe inspector with a written 'stateMent indicating/.thefollowing (or something similar) :,..... .,:,., :,-:. . /..-.A, , . : .:-, ,,1 •,,i; '!=. ',I, ,,,,, ...,,,!.:: I HAVE INSTALLED A ROOT::.MEMBRANEA A SSEMBLY0:NCLI.JDINGiNSULATION IF 1 APPLICABLE, CONSISTINGOFMANUFACTURER) W , SUCDATION # _ , DATA ., SHEET ENCLOSED , WHICH MEEtS,fibk.*UOPSij*.REOUIREMENTS FOR aASS A OR CLASS B ROOFS, THIS ROOF VAS'iN5tALLED-AT (ADDRESS), UNDER CITY OF TUKWILA PERMIT NO. . (The statement shall Include the name of the roofing company that installed the roof, signature of installer and date.) • CITY OF TUKWILA Permit Center( 6300 Southcenfer Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Pr Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant: rr NecaoF 5 bt4i 1cli�Us for. i14j/t i i vl anav✓l2ent `,wl tilki alue of Construction: (.0,5oZ Site Address: .5 l.)) 4. v`, a U< tt� ft ve Tu IL (,)1 la „ City Stat /Zip 7 1 Idashugtnv1 9818 y Tax Par el Number. 1 02� 54c)--U0r�c:) P pert Owner: Hof_ /tieocl /llafageittev1.r Lail f .r li _ Phone: 62o - 6-�.f -1 2 i Fax #: q- ti'25•-• Street Addr ss: .., j City State /Zip: l .u. t f �. , /< . I2 �,, , ,,z t`; /, -. , Contact, Perso .,, �ij"_ iliL ( a Ur) LA- I ,2 1 Ile •T i Phone: , .1 1 1 l Street Address: yy�� e .Qiii i e a j t 6ve City State /Zip: Fax #: 1` , 1 Contr ctor: / el, 1 c04 1" V,Un \r i I�ck. (n , �. vt G t 0 Metro 0 Standby Phone: / 2816/ I I 6 - 52`7 /'/ Skeet Address:_ ,..) lJ i fii3O IbaX 7 /5o ..Sc� 1 /C, �Cl.$lt1g City State /Zip: an 811107 oi' Fax #: ,2 e- 2 y- /0,5g f Architect: 4 1 Phone: Street Address: City State /Zip: Fax #: Engineer: /1/1/ Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) :. Description of work to be done: ?ea t' c 4c eXi !•. k s vu re)• ,0L. •ti to dec etitd. j bt S%'r.� 1 ( A. { I Will there be storage of flammable /combustible hazardous material in the building? ❑ yes E1 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Bulkhead /Docks Pa Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection /Exit Systems ❑ Temporary Facilities ❑ Tree Cutting E APPLICANT: REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS(' ❑ Channelizatlon /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous in Moving Oversized Load/Hauling ❑ Curb cut/Access /Sidewalk Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft.grading /clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only MONTHLY SERVICE BILLINGS TO: Name: I v �,,i I Phone: Address: City /State /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Address: Phone: City /State /Zip: Value of Constructlon - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application acce //pted: Date application expires: 9 Appllcat%rhtaken by: (Initials) ALL MISCELLANEOUS PEA T APPLICATIONS MUST BE SUBM D WITH THE FOLLOWING: A ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN A BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED A ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT A STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER A CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ri SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW Submit checklist No: M -9 Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 71 Antennas /Satellite Dishes Submit checklist No: M -1 El Awnings /Canopies - No signage Commercial Tenant Improvement Permit 0 Bulkhead/Dock Submit checklist No: M -10 im Commercial Reroof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3, . M -3a 0 Fences - Over 6 feet in Height Submit checklist No: M -9 0 Land Aftering/Grading/Preloads Submit checklist No: M -2 Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 0 Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 0 Miscellaneous Public Works Permits Submit checklist No: H -9 El Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 0 Moving Oversized Load/Hauling Submit checklist No: M -5 d Parking Lots Submit checklist No: M -4 0 Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 J Retaining Walls - Over 4 feet in height Submit checklist No: M -1 EI Temporary Facilities Submit checklist No: M -7 El Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 0 Tree Cutting Submit checklist No: M -2 Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent if the applicant is other than the owner, registered architect/engineer,or, contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 0, ry� /� et J 1 1 -= Date: 6...,R.....? Print name: r i fc W. t�; 1e Phone: o?ld- 7&1/.4y/ Fax 1i: n246,. 2r4,... 44..'8' Address: ,} _ �l (� I ,, I5" �' /4 v N A) City/State/Zip: , Ye *t t% &47 f870 7 A• *A *# A Ai;,►:•AA *a: * *11 *a *h*..1 *.A*ik* . ** * *i *,l ** *..c *, * *A *,l *k� *.* n.4*,,t,l * *A* *** * *,t. CITY OF TUKWXLA. WA 'fI1ANSMIT *• *4,1t%k**A * *A. lost *7 ;i11* t**, 1* *0 * *el*A44. *** *•A•k *•k4 “*A* * *A *k**.k.A*A•.>tA* TRAr8t1IT Number: 89700.824 .Amount: • 11291.3(Y:09/03/98 .1:$ :59: PECvnment. Method: CHCC.K Platat1Qri: HAICHT ROOF):NG xriii : BLH • (Permit; Pia: N190,-0101 Type: M3'CICPERtd MISCELLANEOUS' RIT PAY °c:el tea.: 022340!-0030 :Site Address: 500 INDUSTRY DU Lar..at.ian:, BUILDING 412 Total Fees: 11291 50 This Payment 11291.50 Total ` ALL Parts: 1129)-5.0 Balance: A *•A•A, lot**1 14— Akdr** A***t l*rk,t *k *# * *h-,t.*4 * * *A *IA*** kit ** **• * * *A * * *1 * * * *. Account Code De5c:ri of i an Amount 000/322.100 BUILDING - I?C;3. ,..•. . 643.50' 000 /396.904 STATE BUILDING. SURCHARGE ' 4..50 ”. 000/322.800 BUILDING .INVES.T.1,CIH.TiON 643..50; i r'r INSPECTION NO. le 0, INSPECTION RECORD‘ Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 ProjV ty,/,}rrew //rk..7.,, et_WI-L , Type of 112spection:? t.-e-s-ra..../- Address: .1 v,1-0 e , Date called: Special instructions: e i.,_ •••• ele- j„-e"'_ "CA' 'AC."1... Date wanted: ...4 -.27— 4.2 (-:_az......9n. s•—• p.m. Reque,sterk //-- ,. i 46/2-724--, Phone: 6.v.0 ) 625-"ev6 75' pproved per applicable codes. E Corrections required prior to approval. COMMENTS: Date: 3 r] $47.00 REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 PECTION RECORD Retain a copy with permit" CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 (206) 431 -3670 Project: it l ��" / l /7jCalled: ilr° of Insped'an .- /�41 °9 "'T 4Address�,/��jj''�f�'''' S�f� fefill Date Wanted: _3...,9 g 4:20•,m. Requester: Phone No.: ❑ Approved per applicable codes. ❑ Corrections required prior to approval, COMMENTS: Le64/4-).--- :.4 L (5` , _ / Lfri-frr-oco /fir 21/'�-i ��D,I�O5 t 004— (Sit __` 46=- l7 / Joc - -1`‘"ec. '%• t, (-11-41-56 SiVi (AX)R-t.,-- ° • - 6 i i r r 137- rss r/ l'- 3 -- nspector: j 1-9 Date: .y 91 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. `.5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project:l�aj1W40� M jj �� `` ( "` to " Type of lns `tio/ntk .Q..r • i Of �/ Addr ` T>�.d�i� ��. Date called: 7-d, 00 - SSpecial instructions: COI 11 fro-Iv 1 V‘ m0vi' Iht I a-U. set. Inn Pet -� ,�, Movms�, . 7 3 0 -33 3-2- Date wanted :Q j a.ir. V- `"0d P. . Requester: r l --Phh5(0 - 7gi-1- 841 ILI a ElApproved per applicable codes, COMMENTS: ElCorrections required prior to approal., Sae -607 e-tj �• e /1 fr—e-J �� ! Inspector: Date: (5' _ /4 El $47. REINSPECTION F I1REQUIRED. Prior to inspection, fee must be paid' at 6300 Southcenter Blvd., Suite 10p. Call to schedule'reinspection. 1 1 Receiot No: 1 Date: INSPECTION NO. r4 "' INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 <11 PERMIT NO, \\\ (206)431 -3670 P[ ect:t t` Ty.e of Inspgction: f :. dress: AIRS .11l. / >, Dr r e called: ap--,y DO Special instructions: t wanted: ^� OC.- i it Requct { Phone: --/ rq ..... z iiiti ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: r -C) F4c- Date: U/ $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. !Receipt No: I Date: L PLA�EW /ROUT SLIP ACTIVITY NUMBER: M198 -0101 DATE: 6 -8 -98 PROJECT NAME: HALLWOOD MANAGEMENT COMPANY XX Original Plan Submittal Response to Incomplete Letter Revision After Permit Is Issued Response to Correction Letter # DEPARTMENTS: B P ng,Diivision r�s Fire Prevention Structural Planning Division n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 6 -9 -98 Complete E Comments: Incomplete 0 Not Applicable 0 TUES /THURS ROUTING: Please Route No further Review Required 0 Routed by Staff 0 (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7 -7 -98 Approved 0 Approved with Conditions Not Approved (attach comments)IZ Cowreal (IX_ 17/ -÷ haat& (a- iz- REVIEWERS INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE: Approved 0 Approved with Conditions 0 Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE: \PR•ROUTE.DOC 6198 PLA LIP ACTIVITY NUMBER: M198 -0101 DATE: 6 -15 -98 PROJECT NAME: HALLWOOD MANAGEMENT CO Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # 1 Revision After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural E Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) DUE DATE: 6 -16 -98 Complete Comments: Incomplete _ Not Applicable 0 TUES /THURS ROUTING: Routed by Staff Please Route 0 No further Review Required (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions 0 REVIEWERS INITIALS: DUE DATE: 7-14 -98 Not Approved (attach comments) 0 DATE: CORRECTION DETERMINATION: DUE DATE: Approved n Approved with Conditions 0 Not Approved (attach comments) 0 REVIEWERS INITIALS: DATE: \PR•ROUTE,DOC 6/98 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M198 -0101 DATE: 6 -15 -98 PROJECT NAME: HALLW00D MANAGEMENT CO Original Plan Submittal Response to Incomplete Letter _IX_ Response to Correction Letter # 1 Revision After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) / Complete Comments: Incomplete DUE DATE: _ 6 -16 -98 Not Applicable ❑ TUES /THURS ROUTING: Please Route ❑ No further Review Required Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE. APPROVALS OR CORRECTIONS: (ten days) Approved ❑ Approved with Conditio REVIEWERS INITIALS: DUE DATE: 7 -14 -98 Not Approved (attach co ments) ❑ DATE. CORRECTION DETERMINATION: DUE DATE: Approved ❑ Approved with Conditions.❑ Not Approved (attach comments) ❑ REVIEWERS INITIALS: DATE: \PR.RC)11TF_F]CIP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PROJECT NAME: M198 -0101 HALLWOOD MANAGEMENT COMPANY DATE: 6 -8 -98 XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter Revision After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues, Thurs) Complete Incomplete Comments: DUE DATE: 6 -9 -98 Not Applicable E TUES /THURS ROUTING: Please Route 0 No further Review Required 0 Routed by Staff ❑ (if routed by staff, make copy to master file and enter into Sierra) REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved 0 Approved with Conditions 0 REVIEWERS INITIALS: DUE DATE: 7 -7 -98 Not Approved (attach comments DATE: CORRECTION DETERMINATION: Approved Approved with Conditions 0 DUE DATE: Not Approved (attach comments) REVIEWERS INITIALS: DATE: \PR•ROUTE.DOC 6/98 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director February 7, 2001 Doug Millett 617 Industry Drive Tukwila, WA 98188 RE: Permit Application No. MI98 -0101 500 Industry Drive, Building #2 Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3870 to schedule a progress / final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one-time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to February 18, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincere! Stefanie Spencer Permit Technician Xc: Permit File No. M198.0101 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206. 431.3670 •: Fax 206.4313665' "SINCE 1919" July 20, 2000 HAIGHT ROOFING 6oMPANY, INC. Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 784-8414 INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK • Fax: (206) 784 -1058 INSULATING CONCRETE ROOFS DECKS REROOFING SPECIALISTS Mr. Bill Rambo City of Tukwila Department of Community Development 6300 Southcenter Blvd., #100 Tukwila, WA 98188 RE: Permits MI98 -0101 through 98 -0105 Dear Mr. Rambo: Haight Roofing Company, Inc. has installed a roof membrane assembly, including insulation if applicable, consisting of Malarkey, specification #M3 -XHA, data sheet enclosed, which meets or exceeds the requirements for Class A or Class B roofs. This roof was installed at 515 Indushy Drive, Building #2, under City of Tukwila Permit NO. MI98 - 0101. If you have any questions, please call us at 206 - 784 -8414. Sincerely, HAIGHT ROOFING COMPANY, INC. Karl Kupser Superintendent Attachments (2) KK:twd Members: Western States Roofing Contractors Association ;/ National Roofing Contractors Association 4NCOMPA ROOFI M3 -XHA 4 -1 M3- CONVENTIONAL Deck Type - Uninsulated Rating Slope in 12" BASE SHEET ATTACHMENT Depending on Deck Type Change Spec Number to Read* Mech. See Gen. Req. Fast. Asphalt Combust. /Nailable Wood N/A 2" F.2 Hot Asphalt M3 -WI -XHA -H N/A Structural Concrete A 2" C.7 M3 -CI -XHA -H X M3 -CU -XHA -H Lightweight Concrete N/A Hot Asphalt M3 -LI -XHA -H Metal A N/A Metal N/A M3 -MI -XHA -H Structural Wood Fiber A 2" N/A Structural Wood Fiber N/A Gypsum A 2" F.6 N/A Gypsum N/A A 2" F.4; F.7 Hot Asphalt N/A Precast Slabs N/A N/A Deck Type - Insulated Rating Slope in 12" Insulation Attachment See Gen. Req. Roofing Attachment to Insulation Depending on Deck Type Change Spec Number to Read* Combust. /Nailable Wood A 2" F.2 Hot Asphalt M3 -WI -XHA -H Structural Concrete A 2" F.4 Hot Asphalt M3 -CI -XHA -H Lightweight Concrete A 2" F.5 Hot Asphalt M3 -LI -XHA -H Metal A 2" F.3 Hot Asphalt M3 -MI -XHA -H Structural Wood Fiber A 2" F.8 Hot Asphalt M3 -SI -XHA -H Gypsum A 2" F.6 Hot Asphalt M3 -GI -XHA -H Precast Slabs A 2" F.4; F.7 Hot Asphalt M3 -PI -XHA -H Re er to Tab 2 for eneral Requirements: Responsibil t es, quality control, dec cons era t on, and of er general top cs. Refer to Tab 11 for Products and Associated Materials information. Refer to Tab 6 for Execution Specifications. Refer to Tab 7 for Flashing Details. Change last Character (H =Hot Asphalt): S=SEBS Hot Asphalt The same material must be used to attach the membrane to Insulation. May 5, 2000 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Doug Millett 617 Industry Drive Tukwila Wa 98188 RE: Permit Status MI98 -0101 500 Industry Drive Dear Mr Millett: In reviewing our current permit files, it appears that your permit for a re -roof, issued on September 3, 1998, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, gaitSlis Bill Rambo Permit Technician Xc: Permit File No. M198 -0101 Duane Griffin, Building Official. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431= 3670. Fax 206. 431.3665 JUN -15 98 13:25 FROM:HRLLWOOD CQrMERCIAL 5751415 1. HALLWOOD COMMERCIAL REAL ESTATE, INC. • RRQKEMud • PROM,RTY a CONSTRUCTION MANAGEMENT • TO: '4313665 r PRGE:02 617 INDUSTRY DRIVE TUKWILA, WASHINGTON 9M1.86 (206) 575.6675 FAX (206) 5751415 15 June 1998 Ken Nelsen Plans Examiner City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: M198 -0101, M198 -0102, M198-0103, M198 -0104, M198 -0105. Dear Ken: This letter will confirm that the heated office portions of buildings 2, 3, 4, 5, and 8 located at the Andover Executive Park, have an R value of 30 in the space located between the roof deck and suspended ceiling, If you have any more questions, please give me a call. Thank you. Sincerely: Doug Millen Property Manager RECEIVED CITY OR' TuKyo.A JUN 1 5 1998 PERMIT CENTER. ATLANTA • BALTIMORE • DELLEVUE • CLEVkL■Np • DALLAS :• DEMI ORN • OgTROIT• SACRAMENTO•. $AN D16c:U. City of Tukwila John W. Rants, Mayor June 12, 1998 Department of Community Development Steve Lancaster, Director Doug Mil lett Hallwood Management Company 617 Industry Drive Tukwila, WA 98188 Dear Mr. Millett: SUBJECT: CORRECTION LETTER #1 Development Permit Application Number MI98-0101, M198-0102, MI98-0103, MI98-0104 and Mi98-0105 Hallwood Management Company 500 Industry Drive - Building #2, 515 Industry Drive - Buildings #1, 3 and 5, and 596 Industry Drive, Building #8 This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Division. At this time the Fire Department, Planning Department and Public Works Division have no comments regarding your application for permit. The City requires that two (2) complete sets of revised plans, per building outlined above, be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431- 3671. Sincerely, Lktutk_ 4b-C..cfr Brenda Holt Permit Technician Enclosures File: 1.--s.:1198-0101, 198-0102, MI98-0103, MI98-0104, M198-0105 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188. (206)431.367Q • Fav (206) 431-3665 r BUILDING DIVISION REVIEW DATE: June 11, 1998 PROJECT NAME: Hallwood Management Comp. re -roof application APPLICATION NO: M198 -0101, 102, 103, 104, & 105 PLAN REVIEWER: Ken Nelsen, Plans Examiner (206) 431 -3670 Washington State Energy Code Section 1132.1 requires that re -roof repairs comply with W.S.E.C. Table 13 -1. The submitted application indicates that only one layer of 3/4 inch Perlite insulation board is proposed. Because 3/4 inches Perlite insulation has an R -value of approximately R -2.13, the re -roof can not be approved as submitted. Please provide additional information to show how compliance to the Energy Code will be achieved. No further comments at this time, "SINCE 1919" H IGHT ROOFING COMPANY, INC. Mailing Address: P.O. Box 70150, Seattle, Washington 98107 Office Address: 4910 15th Ave, N.W., Seattle, Washington INDUSTRIAL — COMMERCIAL— ROOFING and SHEET METAL WORK REROOFING SPECIALISTS REROOF 5 BUILDINGS AT HALLWOOD MANAGEMENT 617 INDUSTRY DRIVE, TUKWILA, WASHINGTON. Area Code: (206) 784 -8414 We will tear off the existing roofing down to the substrate and dispose of the debris at an approved disposal site. Sweep the substrate broom clean and mechanically attach a 3/4" cover board over a red rosin paper. Mop two plies of Type IV ply sheet set in asphalt and then install a 72 pound mineral . surface cap sheet set in asphalt. The base flashings will consist of mopping one ply of base sheet and one ply of white cap sheet. TAX PARCEL NUMBERS H022340- 0030 -07 - BUILDING 2.AT 500 INDUSTRY DRIVE H022340- 0070 -08 - BUILDINGS 1, 3 & 5 AT 515 INDUSTRY DRIVE H022340- 0010 -01 - BUILDING 8 AT 596 INDUSTRY DRIVE RECEIVED CITY OF TUKWILA JUN -- 8 1998 PERMIT CENTER frU9S.oi�i Members: Roofing Contractors Association, Seattle, Washington / National Roofing Contractors Association Washington State Contractors Registration Number 223.01- HA- IG- HR- C2690K SUN -12 98 14:03 FROM:HALLWOOD COMMERCIAL 5751415 "SINCE 1915„ TO:2064313665 PAGE:02 HAIGHT ROOFING COMPANY, INC. Mailing Address: P.O. Sox 70150, Seattle, Washington 98107 Office Address: 4910 15th Ave. N.W., Seattle, Washington INDUSTRIAL— COMMERCIAL — ROOFING and SHEET METAL WORK REROOFING SPECIALISTS April 8, 1998 Hallwood Management Company 617 Industry Drive Tukwila, Washington 98188 Attention: Mr. Doug Millett Regarding: Andover Executive Park Subject: Reroofing Buildings Number 2, 3, 4, 5 & 8 Dear Mr. Millett: Area Code; (206) 784 -8414 I 1 1 APR 13 1998 COMMERCIAL REAL ESTATE Upon review of the above referenced buildings, and the specifications provided by you, we have estimated a cost to reroof buildings #2 through #5 and #8. The following is a procedural outline of what our quotation' includes. First, the existing roofing and associated sheet metal items will be removed and disposed of off site at an approved facility. The plywood deck will be swept broom clean and inspected for delamination. Should we find any decking that would require replacement this will be handled on a "time and materials" basis. You or your representative will be notified for approval of any decking requiring replacement prior to starting replacement. A layer of red rosin paper and 3/4" perlite roof insulation will be mechanically fastened to the plywood deck. Two plies of type four fiberglass felt will each be embedded into uniform moppings of hot asphalt. Upon this a layer of granular surfaced mineral cap sheet will be installed. All flashing of curbs, boxes and parapet walls will be accomplished with two .layers•• of.c.pe four,.. ply and one_ ply of mineral cap _sheet., . each set in hot asphalt and fastened to the new wood nailer at the top of the parapet walls. All clean up of our debris along with the following items are included in our prices quoted: New prefinished, standard color, 24 gauge copings; counterflashings, gutters and downspouts; 26 gauge stainless steel scuppers; crickets between scupper drains and at the backside of units and /or boxes; new lead flashings; new 2 x treated wood nailers at the perimeter walls using 1/4" x 21" Rawl split drive anchors; new 2 x treated wood blocking under conduit pipes; new sleepers under the HVAC units to maintain a minimum 8" height above the completed roof assembly; and a manufacturer's ten year "no dollar limit" guarantee. °K art OF ,11l�1`A Members: Roofing Contractors Association, Seattle, Washington / National Rooting Contractors Association V Washington State Contractors Registration Number 223.01•HA•IG•HR•C269OK T 0644-C° JUN-10 98 14:03 FROM:HALLWOOD CO ERCIAL 5751415 pa,/ ,.,, HAIGHT ROOFING COMPANY., INC. TO :20 4313665 We will furnish and install the previously outlined roof sytem for the buildings listed below for the following sums. Note: These prices, do not include Washington State sales tax. If 411 bu the total If you would like us to complete this work for you, please sign your acceptance below and return the original to us. Iipon receipt we will schedule this work for you. If you have any questions or we may be of further assistance, please give us a call. Thank you. Sincerely, H OOFING COMPANY, INC. PAGE:03 R••ert Haigh E•timator Accepted by: Membe s: Roofing Contractors Association, Seattle, Washington : National Roofing Contractors Association'., Washington Slate Contractors Ragtstration Number 223.01- HA.IG-HIR C26901( DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL 1,7MCMgri',:.REGIST XISKT.W7EX CCOltHAIGHRC269QRA501119 ATEHEEMPAESA HAIGHT ROOFING COMPANY INC PO BOX 70150 SEATTLE WA 98107 • F6234523)00 (8197) Detach And Display Certificate • • : ,