HomeMy WebLinkAboutPermit MI99-0160 - RIVERTON TERRACE APARTMENTS - REROOF1: :, x,. -a t.a .... . r;. �. ,. �;Y` .,rit.x • - -.,:. �.£,`nRC+'W
MI99 -0160
14448 41St Av.e So.
Riverton Terrace
Apartments
City of Tukwila 1.
(206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MISCELLANEOUS PERMIT
WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES.
APPLICANT IS PROCEEDING AT THEIR OWN RISK.
Parcel No:
Address:
Suite No:
Location:
Category:
Type:
Zoning:
Const Type:
Gas /Elec.:
Units:
Setbacks:
Water:
Wetlands:
004000 -0205
14448 41 AV S
NSFR
MISCPERM
RE -ROOF
000
North:
N/A
Permi t No:
Status:
Issued:
Expires:
MI99 -0160
ISSUED
08/26/1999
02/22/2000
Occupancy: APARTMENT HOUSE
UBC: 1997
Fire Protection:
.0 South: .0 East: .0 West: .0
Sewer: N/A
Slopes: N Streams:
Contractor License No: ACCESRI071D6
OCCUPANT RIVERTON TERRACE APARTMENTS Phone:
14410 41 AV S, TUKWILA, WA 98188
OWNER KING COUNTY HOUSING AUTH
15455 65TH AVE S, TUKWILA WA 98188
CONTACT RICK NESHEIM Phone: 206 - 363 -5422
924 N 143 ST, SEATTLE, WA 98123
CONTRACTOR ACCESS ROOFING INCORPORATED Phone: 206 363 -5422
924 N 143RD, SEATTLE, WA 98133
**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
RE -ROOF APARTMENT BUILDING (BLDG C)
**************************************************** * * * * ** * * * * * * * * * * * * * * * * * * * * * * * **
Construction Valuation: $ 46,566.00
PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr:
Curb Cut /Access /Sidewalk /CSS: N
Fire Loop Hydrant: N No: Size(in): .00
Flood Control Zone: N
Hauling: N Start Time:
Land Altering: N Cut:
Landscape Irrigation: N
Moving Oversized Load: N Start Time: End Time:
Sanitary Side Sewer: N No:
Sewer Main Extension: N Private: Public:
Storm Drainage: N
Street Use: N
Water Main Extension: N Private: Public:
**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOTAL DEVELOPMENT PERMIT FEES: $ 552.25
**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Date: B-a' 9
End Time:
Fill:
Permit Center Authorized Signature:
I hereby certify that I have read and examined this permit and know the same
to be true and correct. All provisions of law and ordinances governing this
work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or
cancel the provision of any other state or local laws regulating construction
or the perf ianc of work. I am authorized to sign for and obtain this
developrne perms
Signatu
Print Name:_ sL
r-
ft)5sffif //vL
Date: 6` Zco _? `7
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or abandoned
for a period of 180 days from the last inspection.
CITY OF Tisi':.WILA
Addre ss. 14443 41 ;W
::suite:
Tenant :
i'vDe; 111SCPEPM
P tr,c« 1 #: 004000-0205
Per mi t. No: MI99 _0i i0
Status: ISSUED:
A6D1 itad: '08/18/4999
issued: 113(2 x'.1999]
4 'k 4. 'M •k * '4 'k 'k * 'k 'k •4 •.4 k************ :k •k •4 •k :4 •,4 •k •k 'k 'k 'k 'k •4 'k k 'k 'k 'k 'k 'k 4 'k * •k 'k '4 h 'k '4 'k •k •4 'k •k •4 4 'k 4 •k !k •4 •.4 44 k 'k
`Permit Conditions:
1!. :`No chanoe; will . be Made to the D ianS Mil approved bar the
',Entiineer• and .the Tukwila. Bmi l,di,nt :tri.ri s i,orr.
All permits. i ns,Det t.i orr r eCOr .t1 S . , .a),d D 0Ovet1 D 1 ans s ha •i 1 . be
'avai table at the ..ieb s.i}to ar i;or to the S t -ar`,t :�a.t any curs-
,str'.trc'ti+.n. The e :dO -cu ent; are to he'ma ijo tai neik• and av:ai'i
:able until t,irai i:n recticn`a0 rova`1 is Syr•anted:
'_. ;Electr "1c 1:.kj t't11 he `obt 'tned :t hroti! h-2.the rata;P1ir�
',State 1?; '.ti^ ion o`r.:Labott- and, .Industr :ies and '.��.11 e 1et.tv' . Ca.1 :.
•
tyro ►H P, wi P1. ° ;be iti pe -tted .hti that agency ''t";?4 ,-66 O,i
1u »rbirilX' l�r'- r'fiiit_ .h .1:1` he obta ined thr..uugli''•tht' Batt na
County-, Department of Pub li t. ,Hee 1 the P1 u;trl, ins 1 l be
inspec:ted.bv that acen,c.v c'ludina all !xas, piping
t 296 4.722:x.
`■. A'l 1' mec h►an1c.a1 :work • ,.ha1 P be: :vr ier sen.arato Der•mi',t i:: stied 'b.y
t he: '1 i t :v 0..i.7:: Tuk:wii la ..,...:
b A•11 :con 't:ru t ion to:,be • dune in contornr;arzc.e wi th apt ro,v.ed
:D'i3.ari � and r ~ec-ruire»ient 'Of. the.' ;Unl'tCrfl Bu11;di6 Code 11997,.. • ;Emit lon) .a:. .amende"d: •.t.in1to rin i°ieChan tea ,P' Code (1 '97.Ed1,t•ion).
and Wash inutcm' State .Ener ciW''.Code (19 97 „Ed1•i ;t ion.> .
I. Val'iditu. :Ot Permit:'. .ime. r ;s'p;an�ae` o,t a ter'n►it oi" aP►t�,r•o.ral o •
D1'at) sDecit',ica�t•1on and: t.orlr)utat'iont ;h.a11 riot b.e coil-
,:.tr:ued to be ,;.a De'r "O't ,i- r�.. oe -,,an aD"Dr c�v:a i..ot . an 'fir,lat.`ior►
Of FarlV' '«f. the DroV.iS•iortir of the ",k,iii ldin,+ !Cade'. or of anv
other. Cretin flt't of the ilir•_1 tiittt n %v 710 D€ (iit pry?. UI) iri!a
give:`author 1t`,v, °.t6 .violate or camel' the i.)r.'O.'d1'S.iufl Ot tlyis
c.otie ha 1 :1,'h'e valid.
CITY OF TU1k7ILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Miscellaneous Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mall or facsimile.
Project NameiTenant. ( /'
jel `�--•
Value of Construction: v{ to t '5-6, f.
i ' }`=rte C
t II� R`r ) 7 rz k'— ,t7—
Site Address: City;State/ r
I t-11-f0®, Li 1 AtE6, `cE'cw �Brb�
Tax ?Lj ti[ r �/--b
j 00' ° ICS
�w'.
Property Owner: 1.: �ji:,,: 1 i (
e�! lu r ' t-tS'r w Ce ' (Lt;irti:r( -i. 11', i it :, l' ,y . �• I I
phone: i
f I ; .i !i i, . 2, V qt.- ? 9 D
Fax #.
Iii...
Street Address: 1 . 1 ! ;., . i , I City�State /Zip: "'.
-S!t
• (.5.VS 1 6 1 liktr L/9 i i:-?cf-/8®
Contact Perso • ne-ki ES (-IrE /1n i i. ;'
Phone: 3 -3 -- " 2..L
Street Address: R.n .i City State /Zip: '
7 Z-`/ /t). rcf3 5X , A-Vt< 4Sr ¶'3
Fax #;
Contractor:
GILs 5 Wii/0
Phone:
267(o -3 ro 3- 5 y z 7—
Street Address: p City State /Zip:
Z 4/ �
q 0 / / S?, rZEl2ilk- x'!33
Fax #:
Zc(,„ -3 i,3 - 5'15 1
Architect:
Phone:
Street Address: , City State /Zip:
; Fax #:
I i'
;
Engineer: , `
; Phone:
1
Street Address: City State/Zip::;
FaX ; ,
4';��•F •,•4 `r' /11, 41��r1(N%r�t Jet CIS 1ti Sv LIY,kYll N .• •.f.iT� MVp X•f�:M.:9�iN.1
..... . r,, �it;;f�MlS4'F,i l��,l`gra ,elfi�ii.i �..Vi� 1fVrai iiili.a.A ' a 1
� •...j ," x", °•• .•m •�'T' .- v-r.
' �i ;. t o�= Vft "'gi �•� J 1i .,�'-, 'f�? �A.�)k Win
Description of work to be done: c-1-. T.caaf vv u �':�
, i •'' 1
��.;,
it :I . I ., i
Will there be storage of flammable /combustible hazardous material in;the'building? ; ''� 1 ❑. yea no .' , ''; , j
Attach list of materials and stora • e location on se • arate 8 1/2 X 11 • a • er lndlcatin • • uantities & Material Safe( Data Sheets
■ Above Ground Tanks • Antennas /Satellite Dishes ■ Bulkhead /Dock$ + IN
❑ Demolition ❑ Fence ❑ Mechanical ,
❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedesirla
❑ Temporary Facilities 11 Tree Cutting I •1
Commercial Fieroofr 1 ;I
❑ Manufactured Housing-Replacement
Protection /Exit Systems !�
1,
only
`; l5.1.N4fai :,K t?t IOANTIRK40.aT, F R INISGEIIi'ANtC?DSIR .61,).
QR'i$7RERMf1
❑ Channelization /Striping
❑ Flood Control Zone
❑ Landscape Irrigation
❑ Storm Drainage
❑ Water Meter /Exempt #
❑ Water Meter /Permanent # 'Size(s):
❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule:
❑ Miscellaneous
El Curb cut/Access /Sidewalk 0 Fire Loop /Hydrant (main to vault) #: Size(s):
i
❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq ft grading /clearing
❑ Sanitary Side Sewer if: 1 ❑ Sewer Main Extension 0, Private 0 Public
❑ Street Use ❑ Water Main Extension 0 Private 0 Public
Size(s): : 0 Deduct 0 Water Only
❑ Moving Oversized Load /Hauling
ti10. ;1'HLY&EAViQa01:01NO ito .5
';':i4:t. �E1 :`..q`
' ; Ic7. ii-:.;' ;i _
..,.Cf7 °.:;t1,. ff '• ; );(, v. :,
. "Tri, : ' a`1 7tom , ,t . • {ti,i, .
I .:i:4
Name:
j
, i 1
Phone:
Address:
l
i i
I
City /$tote /Zip: •
I I,
0 Water
0 Sewer
;
0 Metro. •III .: ,
0 Standby
.WA VaTi M4TE'RIDBI OS1T`.RERL) ' CA$111.1:1NG '.k,IVI §;r,' ;iiirizi,s • !t
1,15 it dkintflgAg JIitiiitAiI
Name:
Phone:
Address:
City /State /Zip:
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the •date of application shall
expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days
upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application
shall be extended more than once.
Date app ation gp44,::;)
Pale application ex. es: I 1 :
Appl/cat .0 , en by; In
tigls) '1
ALL MISCELLANEOC'' ERMIT APPLICATIONS MUST BE
MITTED WITH THE FOLLOWING:
D..
ALL DRAWINGS S ALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
D BUILDING SITEiPLANb AND UTILITY PLANS ARE TO BE COMBINED
D ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT
D STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON
LICENSED STRUCTURAL ENGINEER
D CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER
(P.E.)
❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
BtlliditigidcUi,i6t000,1, Fiz`04;0 'ei f' I/ ibi : `''llcaiit.04.1ier�ll ah° tits: ditirier;. re"isterOd archifect/en iiioeri or,cdri!raciar li'celi8ecl ;'!.
I* the S at lof hltigfdh,',`a riota�izetl'li#tfe ?rpm tI1 l3ioperlyaoW}ier aUifiofif ng thc.egent'to sU`l viii f�ls p imif applicaiioii and .
tjbtelmfh$ potm1� tJ,II b'o_reg1J(ied his, subitltfhf,' a ,:,, ,.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDi 0-6.-WNEFT271pAUT
SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW
`AbovillO UndiTetiktsNNater h'eiiii4 '.SUpported�d1rec1Iy tlpoti 'grade'
exceeding 5 000. gallons'anda ratio" of` height to;dfarrmetet' or:;widtN�t
.which' exceeds :i 4 ,.';.• '
SubtTnt cheoiii§t ,:Ntll``Ni =g'`
'4'
Signatur
'Aiitetinas /Satellite.Dishesr i
Submit checkiist' i.:No: M -1
Date:
;Awnings /Canopies ':No signage;: :.:
i ?
ComrnercialTenarit Irriprovement
,permit :;
❑
. Btllkhehd /Dock•
Submit checklist No M -10 .
Phone :Zoe
3c.3- G`/2Z_
`CotnhierciapReitoof ' <,
Submif;checkiist No M =6 ,
❑
Demolitiohi; ` "` ',
.. . , , .. +,.. )• L .. ,.. •:, t. !
Siibhlit ehiect,kii No;tiM�3jr Mp3a '
. :ai.. <am.4 {'.11% < +r' >' .. ; ,,l' :,!,,3, ,,'il (: ! 7 ....
❑
Fetices.= Over 6'feet'rii 1teigtit� "'
Submit checklist, lNo''' :M =9
❑
:Land Altering /Grading /P,reloads,
Submit checklist ,; Not, M °2
ri
Liiading;Docks:t 5k '
.. .. �, .. >. 1r 11 .,1i =ail t t. .. t „1\ ', r .,. ... .�..... ,.
CotiirherciaiTeriaiit itnbtoveliient
.P .6rfiiiti,i §Ubrii1t,'6 dk116t I40k;17 .,
Mechanical . Residential'' &+CofriF'rie aial is'i %;' +i, "iv''.'` `';?'
SUbtiiit.cliecklis Noi M =g-
Resldehtiai:onlyl ., -1.6
Miscellanedtis +PUbltc�WtirkslPertiiits > � ; rf �` +'ji; ,
,: ,1. I, ,1 :, m j , r!r:r}•,,r,,,, r ,,,., ,, p •v� i Stt, 1 t+.'
. ,', t. �.. ..,r r ! .,>:. 1.. t _.•1.. rc. � ?f ,.. �l .. ,�. f .. � ! ..
Subn-irt checkiist" No: W d
< • 2 : ,!`; .! > 5 ., . , , r,..
'i.. .Y�. is
❑
'Maiitifacttifed'Holising (RED�INSIGNIA+ONLY)t� %'�,
•Submit checklist, 'No. M 5
❑
Moving OversizedJLoad /Hatling.'1
Suohiit heklist ; No :> M 5'
❑
; Parkifig!.Lots .
Submit cliecklist; :'No: M -4 •
❑
Residehtial;Reroof'- •.Exempt':with following exception ::'If•roof structure:
ta,be;repairedtor...repl ced . . . ,
Ideside.r�,tlol l3Uilding Petmit
Subinit checkiist' .-.No!: M -6
❑
, Retairilfiw.walls' rOVer.4 feettin height', ;'
SUbrnit checklist 'INo '. MS1
❑
t,Tetitporat*:,, 40 i))1itle
Subtnit:ohecklist .Nb:' M -7
! TT' eiiipoPai' y' Pedesti• iah ;Protectiotii,oit!stems4� ",`
Subrniit:checkiist, No M14
❑
Tree Ctitting 1 ,
1,k .r'i.t.1..Al.>I.L . ♦,.. '.. .. ... .. ..
Subhimt checkiist; Not M -2
. > ;:,-,,,.,'.::,.:/:',..:, :... ... .. ., 3
❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If
not available at the time of application, a copy of this license will be required before the
permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit
in Lieu of Contractor Registration ".
BtlliditigidcUi,i6t000,1, Fiz`04;0 'ei f' I/ ibi : `''llcaiit.04.1ier�ll ah° tits: ditirier;. re"isterOd archifect/en iiioeri or,cdri!raciar li'celi8ecl ;'!.
I* the S at lof hltigfdh,',`a riota�izetl'li#tfe ?rpm tI1 l3ioperlyaoW}ier aUifiofif ng thc.egent'to sU`l viii f�ls p imif applicaiioii and .
tjbtelmfh$ potm1� tJ,II b'o_reg1J(ied his, subitltfhf,' a ,:,, ,.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS
PERMIT.
BUILDi 0-6.-WNEFT271pAUT
IZEIYAGENT :_.
r . .. r .
Signatur
G.��
��� r
Date:
�_�
cjc7:
Print nam .
j�
tc. F`
qq "
lVr�StitEwv1
Phone :Zoe
3c.3- G`/2Z_
Fax # : °C"
3 at. 3-SYSI
Address:g2 t / u, f
r o S7-
City /Stale /Zip
Zf /c9A, k4.133
MISCPMT.DOC 7/11/96
iri;74 ,?....77:(reprmwrgi's tnhomyr,L,r "YirMiCiWWMIWKIj277170,417"Cici:277r117.` •5,ITI.77:1"41"4"4.4
m***4A.A****N********.s*A**A*N**k.A.k****A.**A****++*4-A*****A*k4*A*
CITY OF.T1H■WILA. WA • H-Mlq --01060 TRANSMII
**h**.k**4***A 4rA 4 t . . i . * * * * * * A * . A * * * * * * * * * * * * * * . * * A Jr*k k h
TRANSMIT Number: R9800134 Amount: • 552 25. 08/26/99 1:2:32 •
P4vment. Method: CHECK. Nots.tiont. ACCESS ROOFINS
l'.trmit NO: M99 0160 Typo: MISCPERM MI3CELLARE8US:PEUMIT
Parcel No 004000-0205
13 Wddres%: 14448 44 JO) S
Totto :532±2.15:i
This Payment r.:2.2.25: Total. ALL Pmts: .. 5.:52...25 .
R,alancd.:'
4, * 4,:, * is it 4r ick 'A #.• * iv it it * 4 l'Ov 0* iv * i . 41, + * IC A * 4r .A. k3 ik * iv A lc A k Iv * iv 11- 4■"k * k * * I: :4c is ii. 4 .A. * 11 4-; ;It' it
„ , !•
Account Coda Deseriotion' 00ount.
000/322.100 BUI1 0INW: 77 547.75.:
EMS
000/386.904 STArli BUILDING:SURC.1.1AUGE 1.1 .:50 -
•
•
•
•'•
1
INSPECTION RECORD
Retain a copy with permit
MC1q -olbo
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670
P ri:
��t'r'�ur. i-Pvvoue A i s
Type of Inspecti f: I
,vw
Address:
Iz --v-i t. L. S+ Ad �t
Date called:
V -1 s -o.
Special instructions: ((
Cc ( � - )r ahec,A 1U vtiee1
R,1C1t- �CtS ?P✓ KA1A S
avvck -1 -c\ \e1\ {YS
Date wanted: (� 00
�` p.m.
Requester-0k ++ 1
■1C`C �P ShP�t ►w►^�
Phone:
20(o-363-51-122
FApproved per applicable codes. J Corrections required prior to approval.
14(._. `ft) JAC
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
1 Receipt No: Date:
ACCESS ROOFING
8/18/99
City of Tukwila
Building & Planning
6200 Southcenter Blvd.
Tukwila, Wa. 98188
RE: Roofing Permit Narrative
To whom it may concern
FILE.. COPY
t the Plan Check aPprovals•are
�rScsrstand that and approval of
,a omissian8 n of any
,, . O. errors and r the violation my :tot othnrir.„ .. Receipt os con-
, not. a
r, ;,c�; does or o,rOinanCe, Re l cod•
tot' code •provZtl plans act n0 'led
tt �GyUi iC• •
B rat
ate
Permit No
Access Roofing has been contracted by King County Housing Authority to remove the
existing 3 ply roofing system, and install a new U.L. Class A single -ply roof system. The
building is located at 14440 415` Ave. So. Seattle, Wa. 98168.
The roofing contract amount is $139,700.00 plus sales tax of $ 3,300.00.
Sincerely,
Access Roofing
al+
38+-
4—
t-
?) 2.4 e_,A r. t
o 1-7 •P L. 110.3 L1;) I N
• .5-4,4LE:w, •
p-ATcri SH114/...L17...5
•E G.NA i%t:
r
A. 0■15.K.rt.c StAvz
7
75: 1.17'S
GA AAMTAL...
(Tyric,AL)
kOlikR4okTit`r-
67.1.skc-rez Feicratirl Ft.
• APPROVEL
. • A lo-p
(T•o.)
RECEIVED
AUG 5 1999
\No °D Ikt-TT RS
srar `mkt-
Nrs
4qta. WET Ps
GASICEMP FIVA1
E r.
,
EtN/ cox
KCHA MAittrrirrule-m
9Z' +-
L-oMANd.° TuRBWWI.
CT YO
w
upL V7MI tri(TiT )
iCLck..T (TYR )
SLop� To t'
f REQu3R
Y(ic.4L)
Co�icaG. `T Y?,�
DVEL
7-LP
RECEIVED
AUG 5 1999
• GAP MmTntr KY�oR P.� iuG
New zupts R.ocF DRAINS('TiF )
STa° mu-
scaLz : Nrs
•
-RF-T7 K. Rs
RECEIVED
CITY OF TUKWILA
• a,U6 8 1899
PEW CENTER
6T/VF R MF_M45141:NE
GZ Base SHEAT (Z)
MO TAFeR rksiam-IDN :.. ?sip EF. Vi �o� �jf,R►51 cR
We C. D>< 54+eF,TtiiN�
INNEN
L.7=
Tgchnical Produce Data
Product
Description
Technical
Data
FLINTLASTIC® GTAT-FR
FLINTLASTIC® GTA'=FR/f1
APP Modified Bitumen Roll Roofing Products
Product Use: FLINTLASTIC GTA -FR is designed for use as a roofing membrane over
various types of substrates for both new construction and re- roofing installations. It is
suitable for both low and medium sloped roof decks and may be used in conjunction with
FLINTLASTIC GTA -FR /fl for roof system flashings including wall treatments, base flashings
and field flashings.
Limitations: FLINTLASTIC GTA -FR and GTA -FR /fl are intended for torch application only
and should not be exposed to adhesives or solvent based materials. Rolls should be stored
off ground, completely protected against the weather. Roof decks shall be structurally sound,
dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code
and GS. Additional specifications and precautions are contained in GS's Commercial Roof
Systems Specification Manual.
Product Composition and Features: FLINTLASTIC Modified Bitumen products are
manufactured on a state of the art, dedicated Modified Bitumen roofing line that was exclu-
sively designed for the production of these products. FLINTLASTIC GTA -FR and GTA -FR /fl
are produced with a high performance, non -woven polyester mat and a superior grade fire -
resistant Modified Bitumen compound.
Sizes: FLINTLASTIC GTA -FR — 3934" X 33'3"
FLINTLASTIC GTA -FR /fI — 19 "/16" X 31'0"
Coverage: FLINTLASTIC GTA -FR will cover one (1) square when applied according to
GS's specifications. FLINTLASTIC GRA -FR /fl will cover up to 50 square feet of flashing
area depending upon method of application.
Approximate Weight: FLINTLASTIC GTA -FR — 105 lbs. /rl/ (.96 lbs. /sq. ft.)
FLINTLASTIC GTA -FR /fI — 52 lbs. /rl.
Top Surface: Mineral Granule
Back Surface: Polyethylene Torchable Film
Applicable Standards: FLINTLASTIC GTA -FR Is proven for use in various UL Class A
roof assemblies, including assemblies with aggregate and other types of optional
surfacings. Consult GS and UL Directory for system details and requirements.
Modified Bitumen Coating: Non - oxidized (Flux) asphalt, blended with various
thermoplastic atactic polypropylene polymers and co- polymers
Support Mat: High performance, puncture and tear resistant non -woven polyester mat.
Test Description Test Method
Softening Point: ASTM D -36 310'F
Tensile Strength: ASTM D -5147
• 73.4 +/- 3.6 °F MD /XD 106/92 lbs. /in.
• 0 +/- 3.6 °F MD /XD 133/116 lbs. /In.
Elongation: ASTM D -5147
• 73.4 +/- 3.6'F MD /XD 57 %/62%
• 0 V- 3.6'F MD /XD 20 %/22%
Dimensional Stability: ASTM D -5147 MD /XD 0.5 %/0.3%
Low Temperature Flex: ASTM D -5147 Pass CO 10'F
Compound Stability: ASTM D -5147 250'F
Thickness: ASTM D -5147 4,2mm
NOTE: Published results are nominal production values. Products m the
Canadian General Standards. 0 tie
•• •• A % _ _ _
Product
Application
Warranties
Technical
Assistance
and Services
FLINTLASI` Modified Bitumen roofing systems shall l applied in accordance with installa-
tion procedures contained in GS's Commercial Roof Systems Specification Manual. The fol-
lowing information is intended for general information purposes only and is not all- inclusive.
Preparation: Substrates to receive FLINTLASTIC GTA -FR roof system shall be firmly
attached, smooth, dry, clean and free of sharp projections and depressions. Substrates
requiring priming shall be primed with asphalt primer and be allowed to completely dry.
Substrates shall provide positive drainage. Roof shall be tapered to drains.
Installation: Consult UL Directory for system requirements. Install one or more plies of
GLASBASE or other GS approved alternate Base Sheet lapping 2" on sides and 4" on ends.
Base sheet shall be mechanically fastened to nailable substrates, and either solid or spot
mopped in hot asphalt to non - nailable or insulated substrates as specified in GS's Roof
System specification. Apply base sheet in such a manner to provide and maintain a minimum
6" offset between side and end laps of base ply and FLINTLASTIC finishing membrane. Over
the base ply, install one ply of FLINTLASTIC GTA -FR lapping 31/4" on sides and 6" on ends
with end laps diagonally staggered, not less than 3 feet apart. Side and end laps should be
inspected to insure a minimum 3/9" flow of modified compound has been achieved.
Precautions: Cold weather applications require special handling to prevent damage to the
rolls and to insure satisfactory installation. Do not apply roofing systems over improperly
prepared substrates or substrates which contain moisture. Follow all safety recommen-
dations relating to the use and maintenance of liquid propane gas torches and equipment.
Refer to the GS Roof Systems Specification Manual for additional safety information.
Maintenance: FLINTLASTIC Roof Systems do not require any additional maintenance
beyond yearly roof maintenance procedures. GS recommends regular roof maintenance and
inspection to determine the condition of drains, flashings and other similar items.
GS Roofing Products Company, Inc. offers a number of different types of Roof Membrane
Warranties designed to meet the building owner's specific requirements. Contact your near-
est GS office for additional information and requirements.
GS provides technical assistant in the design, selection, specification and application for all
GS Commercial Roof Systems. Architectural and field representatives are available for
consultation within each region. GS inspectors may make job -site inspections on all projects
where a GS Full Value Roof Membrane Warranty is requested and application is approved
prior to the installation of materials.
• WESTERN REGION
2/55 Las Positas Cr.
Suite V
Livermore, CA 94550 -9583
(510)606-7434
(800)955-0811
FAX (5/0) 606 -1097
MINN MINIM
1 NE um= Roofing
GS REGIONAL SALES OFFICES ❑ EASTERN REGION
552.5 MacArthur Bled.
Suite 900
!ruing, TX 75038
(2/4)580 -5604
(800)333-7663
FAX (214) 580 -5692
G R P -3004
ACCESS ROOFING
May 12, 2000
Department of Community Development
6300 Southcenter B 1, #100
Tukwila, Wa. 98188
RE: Riverton Terrace Apartments
To Whom it May Concern,
Access Roofing has installed a roof membrane assembly, including
insulation, consisting of Atlas tapered polyisocyanurate insulation, GS
splecification GTA -2 -3, Data sheet enclosed, which meets or exceeds the
requirements for class B roofs. This roof was installed at 14448 41 ave S.,
under city of Tukwila permit No. M199 -0160.
Thank You,
Rick Nesheim
Access Roofing
May 5, 2000
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
Rick Nesheim
924 N 143rd St
Seattle Wa 98123
RE: Permit Status MI99 -0160
14448 41st Ave S
Dear Mr Nesheim:
In reviewing our current permit files, it appears that your permit for a re -roof, issued on August
26, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila
Building Division.
Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
building official under the provision of this code shall expire by limitation and become null and
void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, if a final inspection is not called for within ten (10) business days from the
date of this letter, the Permit Center will close your file and the work completed to date will be
considered non - complying and not in conformance with the Uniform Building Code and/or
Mechanical Code.
Please contact the Permit Center at (206)433 -7165 if you wish to schedule a final inspection.
Thank you for your cooperation in this matter.
Sincerely,
Gilf? gg1)—
Bill Rambo
Permit Technician
Xc: Permit File No. MI99 -0160
Duane Griffin, Building Official
C
Pcxrv+ Cxycya .
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M199 -0160 DATE: 8 -18 -99
PROJECT NAME: RIVERTON TERRACE APARTMENTS /RE -ROOF
XX Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # _ Revision # _ After Permit Is Issued
DEPARTMENTS:
Building ivision
AVG 'H47
Public Works n
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
DUE DATE: 8 -19-99
Incomplete n Not Applicable
Comments:
TUES /THURS ROUTING:
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: (ten days)
DUE DATE 9-16-99
Approved n Approved with Conditions, Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
CORRECTION DETERMINATION: DUE DATE
Approved n Approved with Conditions n Not Approved (attach comments) I I
REVIEWER'S INITIALS: DATE:
\PRROUTE.DOC
1
• '
Af • ....AAJANt A f A,A),
MASTER LICENSE SERVICE
REGISTRATIONS AND LICENSES
STATE OF
WASHINGTON
UNIFIED BUSINESS ID 0: 601 451 980
BUSINESS ID 0: 001
EXPIRES : 03-31-2000
ORGANIZATION TYPE
DOMESTIC PROFIT CORPORATION
ACCESS SERVICES INCORPORATED
924 1 143RD
SEATTLE WA 98133
DOMESTIC PROFIT CORPORATION
RENEWED BY AUTHORITY OF SECRETARY OF STATE
REGISTERED TRADE NAMES:
A R SUPPLY
ACCESS ROOFING.AND CONSTRUCTION
ACCESS ROOFING
LEAK REPAIR SPECIALISTS
The above entity has been issued the business registrations or licenses listed
DEPARTMENT OF LICENSING, BUSINESS & PROFESSIONS DIVISKA
P0. BOX 9034 OLYMPIA. WA 98507.9034 (360) 664.1400
{x(1,77 SP
1)F.I'AI■TN 01: 1\1()R AND INDUSTI■ Ir. S
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST. # EXP. DATE
CCO1 ACCESRI071D6 05/01/2000
EFFECTIVE DATE 03/26/1993
ACCESS ROOFING INCORPORATED
924 N 143RD
SEATTLE WA 98133