Loading...
HomeMy WebLinkAboutPermit MI99-0161 - RIVERTON TERRACE APARTMENTS - REROOFMI99 -0161 14471 41st Av.e So. Riverton Terrace Apartments kL o aA `i YtYP.R. City of Tukwila ( (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 004000 -0205 Address: 14471 41 AV S Suite No: Location: Category: NSFR Type: MISCPERM Zoning: Const Type: RE -ROOF Gas /Elec.: Units: 000 Setbacks: North: Water: N/A Wetlands: Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: .0 South: .0 East: .0 West: Sewer: N/A Slopes: N Streams: Contractor License No: ACCESRIO71D6 OCCUPANT OWNER CONTACT CONTRACTOR RIVERTON TERRACE APARTMENTS 14410 41 AV S, TUKWILA, WA 98188 KING COUNTY HOUSING AUTH 15455 65TH AVE S, TUKWILA WA 98188 RICK NESHEIM 924 N 143 ST, SEATTLE, WA 98123 ACCESS ROOFING INCORPORATED 924 N 143RD, SEATTLE, WA 98133 **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * ** * * * ** Permit Description: RE -ROOF OF APARTMENT BUILDING (BLDG A). **************************************************** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 46,566.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: **************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 552.25 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *• Phone: MI99 -0161 ISSUED 08/26/1999 02/22/2000 APARTMENT HOUSE 1997 .0 Phone: 206 - 363 -5422 Phone: 206 363 -5422 Size(in): .00 End Time: Fill: Public: Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the perfor : of w• k. I am authorized to sign for and obtain this developme Signet Print Name:_ Date: g.P"—La , -97 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TU1''.W1 LA Addr'e : 14471 41 AV S. Suite: Tenant: Type: MI SCPERM Parcel l ,'!': 0040(10 -020 k'. 4. 9' F9• k• F• 4. y4' 4: 4' N*• k• h• FF. 94F. FF9' FFk 9• h' LF' Fk p99' M '.999•k'k•4•h'kF9•F•4;F•A•F4.4. 9999 *•9.wF'4•4*•94•F•F.p'.4*i,k•4 Permit Conditions: 1.. No chanoes, wi l 1 be made to the marls unless a,uoroved by the Eno1neer.• and the Tukwila Bu,:il,d.ina:Dj'fision. iA11 permits. lhs Pect;n.n,,..te.ords.'`. nd', :aPpro ed plans shall ,be available at the iteirior to the st.; rt. of any con- ,:.truct' un 1 'he.:e °documents .arse tcir be maintained--and c via i l ,ab•1e until 1 ',i,na1 in .rect:Jopa «r-•o• al is 'ran .eci; Electrical •oer M i ts;: Shall . be nhttained` -flit oUgh,'`the Wrash i nci tor/: State Criv-i:,iov1 of L•c3hor and. industries and`ali. electrical aror�t wi 11`:he .ir;:.pect ed b�� that a+�enc:v tL.;48- b6•30) . 4. 'P lumbin&i rrerm i t sh.a 11 be obtained thr=ough .the' Seattle-'�t�:'ina 1.ounty.:Department of Pubiis`Healt'h. I lumbino. will be insp ct;..ed :by that ateri'Y.• inC.1udin.x all !:ras piPinq `.'r. All mechanical wor,1< shall be° under- separate permit issued b'v. the l.;i t v o, Tut; . Cry. All, t ~onstruc.t ion to be. bon : i n conformance with aR :ur•a, ed olans and reauir-emerit: of the Un1torm Buildsnu Code (1997 Ldit`1on) as an rlde+.l .Un'ifnrr l'rteclian1 .i Cude (1997 Cd t:ion) ;and: ash i n. tori State ner•ty Code (19i9? Edition). ;r. Via1`i°dity, of permit. The' is,,uani:r. of a .ocr'mtt or approval .:of,: plans. . NeC.iticatiorls. .an'd'c.omoutations shall not be con - tr'.0 d to be ca r*erfliit tor.; or' an at prova.l,.Of. any violati.On : Of any of the pr ov i : i o; s of the, :.bu i I d i nO code or of an.v, other or dinarrc:,e of the iurisdic.tian ,No i:permit oresumin9 O.)/ `:. s.]ive'authoHty to violate or cancel •the:pr'OViSion„ otthis, code Shall, ~'bra rca id, permit taco .11199401 n1 Status: ISSUED: Applied: 08J1 881 999 Issued: 06/2-6/1999 CITY OF TUK, "/ILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant. t urR`I''o� T r-, i(,�,,r)q A �9pAtTMC Jrs_ ,�, !-, Value of Construction: -{ t' t 5 to �, i- cf) Site Address: C LI � � � � / 4r ACE So. � City'S tt t o Z i � S"-#11V1-4f,, Jf41. g //o a c Fit (�@(r J ! OZt3 -,y f - -� Property Owner' � -C. �I-t itP1 1 -6uS ! w� r 1 'o ir{ -Y ./ F,i i 7 1 � � ,:# i..I ;, i, Phon ' i i i I • I; Street Address: I . ': , I I 1 i l Crity; State /Zip. 1. Fa;'c ft• Contact Perso (-k 6„- Hei.in r 1 '.:1, , :. ! i - 1. ! :Phone; �fw3 `-`_;i `f 2-Z L Street Address: y ;U , (� �3 Rri 5r ,r City'. State /Zip: ' 6;'( Fax I. Contractor: ri-GGrLs.5 ' /1��;',t) G 'Phone: Zo( -3 G'3 - 5 4i z z Street Address: el Z /1), V ', /4 " s?, City State /Zip: SrtAlfLe rte.,. 9'8133 Fax #: Zeta —3 t3' Sq 5 Architect: phone: Street Address: City State/Zip: f=ax #: Engineer: i Phone: II Street Address: } y Zna., 1 axi :Ii I. ►L II '' l'1 iiii O rad(1 di! ire if:`liSiiiMiliP: iii (iatA.1/:; _'� f'01_ v' -'n.41 7 j4 tairlre '111 f' vek, Description of work to be done: c'j� ^ • •r ,a 1`�` (9�d'(0L.> i1 �: I `' ''a' ; I ' l I l; '' ' i Phone Will there be storage of flammable /combustible hazardous material in th b ,ildin ?; ', Attach list of materials and storage location on separate 8 1/2 X 11 paper Indica'tin9, ∎ uantities Q yes n :, & Material Safes Data Sheets ❑ Above Ground Tanks ❑ Antennas /Satellite Dishes ❑ Bulkhead/pocks =4 Comnterc al eroo f I I !,, .; i. fl . ►.I t, ❑ Demolition ❑ Fence ❑ Mec�tanical Manufactured Housing - Replace ❑Parking Lots ❑Retaining Walls ❑ Temporary Pede$iria Protection /Exit Systems !' j ❑ Temporary Facilities ❑ Tree Cutting 1 ' , ' i'l' j il �1 , , t I ) 1 ,:, ,., nt only: 1 ' : ' i! 17:777,77,:; ;t,: - -M in..., 5RR0ftAN.. REQi1athFQFi.Mis'OIwt, �,Ot .S�'FiNS�RMlTr" t 'r`' i k 6,(: , "M CI Channelizatlon /Striping CI Curb cut/Access /Sidewalk CI Fire Loop /Hydrant (main to vault) #: . Size(s): i ❑ Flood Control Zone in Land Altering: 0 Cut cubic yards 0 Fill 'cubic yards 0, sq ft.grading /clearing ❑ Landscape Irrigation ❑ Sanitary Side Sewer if: ❑ Sewer Main Extension 0. Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # 'Size(s): ❑ Water Meter Temp # Size(s : Est. quantity: gal Schedule: ❑ Miscellaneous ILI Gloving Oversized Load /Hauling i , :MOUTHIZ'SERVieSalect ' ki�t ��tiittr l rtn t �a a � �� M��atl 65n°Yati3 e r r YuI M Name: , 1 Address: I l; '' ' i Phone Address: r City /Itiate /Zip:. 0 water. ;0 Sewer i (', , 0 Metro (I.I, I„ :0 Standby , t r < .AA! n it :Wi�rE'R,Ma1r R 1RER:OS TIE `fU pgf lf:t li%, "t.. ,t:�s vtt1::l '� 7 e�.x. � y�. ',(41.,4,4 , j+ is' y ,Y � xv,., ff ;�--.. a t,: ,; . 't, it% a lf, i (,a�./�.,a +; , 4 sc::i% .r,. fP �'IA`iNl'i�l�t, ti)Yilti'�;: %M i:�nit:J��, .'+, .iA C�.��l� Name: Phone: Address: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Permit Center to comply with current fee schedules, Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days .: i upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No applicatiorl shall be extended more than once. i ' . I i 1 f, , i l . Dale apnatlo n aepte Dale appllcaUon ex es: ✓`gam a ltc t , PP a rt en by; ln(tl�le)i, iy ALL MISCELLANEOV ERMIT APPLICATIONS MUST BE ' : MITTED WITH THE FOLLOWING: ? ; 141,L DRAV1IINGS SI-id\LL BE AT A LEGIBLE SCALE AND NEATLY DRAWN $> "BUILDINQ'SITE4'LA?IS AND UTILITY PLANS ARE TO BE COMBINED - > ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT Y STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR PERMIT REVIEW ;Slabi nit`ciieciili4L\ Not M ?9 .' `r' ' L,.,„ .. Submit checklist Nn; M =1 ;Abovei0•CiiiHd. 'atiks/Waterftiiilt'st fSrip13or 80 dI •ectly±tUpoli grade exceeding;8s,boo linrisl ndta;'retib ofiheiglif to die ri.eter or,Width;t w�'fchteiE eedsi tit t:f y ' `: i ; +. !:: ''I, +. • ❑ Ahtenhhs /Shtelllte� Dishes F ' �' ; 4 ❑ ;Awn ,t.do. /Canopies No eignage '. • . Commercial-T?enant Improvement .Permit.:‘:::;?.: •' , `' • ❑ 13.Ulkhead /Docit : ; t '' it ' I I Ste , Sublriit checklist .No ' M�10 IN `Cohitrierciel.Reroof `ri{ Submit checklist .No •:M =6 ❑ Demolition S ,' t). I .. i`r• Submit c�ieCklist a; Noi, M 3'' 4M43a+ _ < i, ii' :.t Ifs r' . :f ik1J ❑ 6'feet :i►i eighf ' • ' Fences Over H Stliiiiiit ch'hcklist N8: M 9 = ❑ Land.Altering /Grading /Prelbadst Submit checklist ' , No :. M •2 ❑ ' Loadingipocks , ; ;� r, ' + :',d,',.`s +!I .' Colrimerci i Tenhht ;Ihiprovehietit . . Pthfnit:..Sub`hiit thecklisI.Noi'H =,i7 ❑ Mec hanical (Residentiali& Commercial)I :' l }s' `� ' , ;, I t t , !x jj ty ' �if. Subfiit checklist ' No M=8,' i .. Residehitia(drii ���Wtg, H i:6 r . . ... . ❑ Miscellanediistplililic�Workg' ertiiit ,�',< { ,�';'� r`J`st 't;. .'.i..'...a1: i.t� t? :$,�e`E.'+'i:i: ;s %;, �ti.'' .,, °��,l +`i'i,. Jktff��^," 4 'i SUbrriit!chiebklist '.No; H�, ,,:..),;;;:,,„),,,,w,),),,.,,30,.:,:.! `''' ".! g' 'Manufactu ed Housing ;i(REDtINSIGNIA`ONItY }lsrik.� ' ' ` Submnit'cheokiist�'�No; ,M=5!' ❑ Motling�Oversized Load /Hetiling,' { - _'' Stibtilit checklist `No , M =5 t + ❑ Phrking lots Submit checklist; No: M 74 ❑ Hesidehtial Reroof - .Exempt w!th following exception: If roof structure to..be�repaire�!,or: repit ced' Residential Building, Permit: Submit,checklist A< No : :. M -6 ❑ ERetaiFiitig '.WaIIs�;+Over4feet'inhelght, :'i Submit•ciiecklist '!No :;.M=‘,1 ❑ ! Tehtporairyacflities iJ ` ' r t` '.5 Stabiiiit checklist No: M -7 "ii po hi: "�t edestrihn Proteo'tioii/Eitit =S steriii's +;,r !:,:;i? ` ;': si' f' 11 �\ a? 1 Jf..1 .' .j It i <} i�t .,r ? „!.. >=r -0l,tit.'n'.,l�,t,ti.s; +.t,...' ;;.�i,'. .'.i......� r,.,... ��, `. ... Subiiiit clieakl st,'i<: Noi,', Mi:4i "'; '° il': .I's+ .�'. ,.�•�,.,.... Submit ".checklit 'st No M =2 , ;: ❑ T;reerCUttingt: i'r` ' ” ' ' `` ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Bulldli 00 her %di tlio1104' 4 "elikt,! 1he;.e llcaljt;is >d iii r,�liah tile. dltin'er;,'registeFed. architectierigineeri or cdntr4ctor llcerised ' "i by the'S i leyo( 1ashifigtoh a`iiota} z`'e iliit�ep roiii t�ir / Ndperiy�olMiier a ittjorltlrig the`.agetif:to sUI ,tit this parifnl applicaii0r► and obtain the pe ml ;.WI/Ijb6:;040 eda' s;' paO`of:this'si)bFttll�ali'''�' 1 ,' �t: i HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING r)WNER. IP • . UT ,j • IZEWAGENT::; , .. / 1 r .. , . . I . Date: _ fg , Signatur :: c_..2--- Print nam . Phone :' Fax #: '2--c- Address: z L` `.), c1 12-jj57, c_..E; feAr City /Stale /ZipSk'Ixt t, . (,(1r1. ?:63 f 3 3 MISCPMT.DOC 7/11/96 :t *A.h* * *. * *A'A **Ah * *.. * *k * * *A' *•l * *:1 *•t•,•.4 *•kd * * *•1 :1r'tA *A *4. **:1 * ** * * *. *:i *k.r CITY or •1'UKWIl..A„ WA t"119vl D( / "iftoPd�::hi].T• * **** *;4•A* * * *�r:4:4;1••.1: * ** t:L�::k ** t t.4: t k:t.4,4:1•k:1:1 YOrA*- .1•.:l **A *.,* *.kA* 1r iN Ml: T. Number: 90)01 34 :H mount : 552.25 f)1;3 /26/ 49 12:37 P Eivinent Method: C1.11:tr1(" No at •i (Inc ACCESS ItL INN 'nit:. 'rl:l3 I't rmit Pfau 34I99- 01t•;1 Tvae , MI3CPERid EdIBE.I;I.I.ANI:0138 ., Pt:RAIT Parcel Na tt 004000-0205 Site AdtlreGe c 144'7 .t 41 AV t; 1rw2 Syr: r. 5 ,y 25 y , ¢- 5 2. '' 2 i TFlia �Ey4vnt�!rit: ; a,�... •,� Total ALL f ntf:sa .,.�.,. .�. 13 Ell once ,, 00 *. 4.4 4 ** *tk.AAAA• * * * * * * *4• * *kA **4',Ii t *4. * * * *4** *• k •M*kA*,1 *AA4**4. * *•k *• *.4,1t4*4c • 14.cr.;Q1.I11t Cod c:? 000/3.22.100 0.00 /38E;.204 1)efAc:r'`.1nt.ion f1U]:1:1)] ;44G I3UILlYING 3U10:11A32( E Amount i47.:7Ei 4 ,. 5 t? :• -ttA AM n.i.4'-,!1 Ct:7 it7C 1 rr INSPECTION RECORD Retain a copy with permit INSPECTION NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 o ect: V.wev -101,.., - TIVVG(e. Apis Type of Ins ectioqn: p+ l _Ud. Address: 11-11-110 -i, ��- AVe s Date called: 5 -1 s- oo Special instructions: Cc, 1I ' 1Ar 61 L9& \ AO trap. 't- ,f l■ Cic. lnuN 10 fV vt-� i-4 S ci v, A �'t r.wj- Isi-f r s Date wanted: —' g ' oo .m. Requester^1 `CAL „ eW; �( jV `►� P &0G-3L35I22 one: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date Kid El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No: I Date: MINIM Technical Produce Data Product Description FLINTLASTIC® GTAT =FR FLINTLASTIC® GTAT =FR /fl APP Modified Bitumen Roll Roofing Products Product Use: FLINTLASTIC GTA -FR is designed for use as a roofing membrane over various types of substrates for both new construction and re- roofing installations. It is suitable for both low and medium sloped roof decks and may be used in conjunction with FLINTLASTIC GTA -FR /fl for roof system flashings including wall treatments, base fleshings and field flashings. Limitations: FLINTLASTIC GTA -FR and GTA -FR /fl are intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored off ground, completely protected against the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and GS. Additional specifications and precautions are contained in GS's Commercial Roof Systems Specification Manual. Product Composition and Features: FLINTLASTIC Modified Bitumen products are manufactured on a state of the art, dedicated Modified Bitumen roofing line that was exclu- sively designed for the production of these products. FLINTLASTIC GTA -FR and GTA -FR /fl are produced with a high performance, non -woven polyester mat and a superior grade fire - resistant Modified Bitumen compound. Sizes: FLINTLASTIC GTA -FR — 393/a" X 33'3" FLINTLASTIC GTA -FR /fl — 19"/16" X 31'0" Coverage: FLINTLASTIC GTA -FR will cover one (1) square when applied according to GS's specifications. FLINTLASTIC GRA -FR /fl will cover up to 50 square feet of flashing area depending upon method of application. Approximate Weight: FLINTLASTIC GTA -FR — 105 lbs. /rl/ (.96 lbs. /sq. ft.) FLINTLASTIC GTA -FR /fl — 52 lbs. /rl. Top Surface: Mineral Granule Back Surface: Polyethylene Torchable Film Applicable Standards: FLINTLASTIC GTA -FR is proven for use In various UL Class A roof assemblies, including assemblies with aggregate and other types of optional surfacings. Consult GS and UL Directory for system details and requirements. Technical Modified Bitumen Coating: Non - oxidized (Flux) asphalt, blended with various Data thermoplastic atactic polypropylene polymers and co- polymers Support Mat: High performance, puncture and tear resistant non -woven polyester mat. Test Description Test Method Results Softening Point: ASTM D -36 310°F Tensile Strength: ASTM D -5147 ® 73.4 '/- 3.6'F MD /XD 106/92 lbs. /in. • 0 V/- 3.6'F MD /XD 133/116 lbs. /in. Elongation: ASTM D -5147 ® 73.4 '/- 3.6 °F MD /XD 57 %/62% • 0' /- 3.6'F MD /XD 20 %/22% Dimensional Stability: ASTM D -5147 MD /XD 0.5 %/0.3% Low Temperature Flex: ASTM D -5147 Pass @ 10T Compound Stability: ASTM D -5147 250'F Thickness: ASTM D -5147 4.2mm NOTE: Published results are nominal production values. Products mtlgitftl the Canadian General Standards. M AV 1 R nnnn Product Application Warranties Technical Assistance and Services -. + +.. a+ nrnww�.. nstov�+: WN. YML45finti�. M1�NiJW!' v: iiXPrt 66�lu'+ N./ KVrnr�x�arswererar -- .....rr.w+.w --... w.....�..— .... - -- FLINTLAS( Modified Bitumen roofing systems shall 1pplied in accordance with installa- tion procedures contained in GS's Commercial Roof Systems Specification Manual. The fol- lowing information is intended for general information purposes only and is not all- inclusive. Preparation: Substrates to receive FLINTLASTIC GTA -FR roof system shall be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming shall be primed with asphalt primer and be allowed to completely dry. Substrates shall provide positive drainage. Roof shall be tapered to drains. Installation: Consult UL Directory for system requirements. Install one or more plies of GLASBASE or other GS approved alternate Base Sheet lapping 2" on sides and 4" on ends. Base sheet shall be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non - nailable or insulated substrates as specified in GS's Roof System specification. Apply base sheet in such a manner to provide and maintain a minimum 6" offset between side and end laps of base ply and FLINTLASTIC finishing membrane. Over the base ply, install one ply of FLINTLASTIC GTA -FR lapping 3'/4" on sides and 6" on ends with end laps diagonally staggered, not less than 3 feet apart. Side and end laps should be inspected to insure a minimum 3/e" flow of modified compound has been achieved. Precautions: Cold weather applications require special handling to prevent damage to the rolls and to insure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates which contain moisture. Follow all safety recommen- dations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the GS Roof Systems Specification Manual for additional safety information. Maintenance: FLINTLASTIC Roof Systems do not require any additional maintenance beyond yearly roof maintenance procedures. GS recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items. GS Roofing Products Company, Inc. offers a number of different types of Roof Membrane Warranties designed to meet the building owner's specific requirements. Contact your near- est GS office for additional information and requirements. GS provides technical assistant in the design, selection, specification and application for all GS Commercial Roof Systems. Architectural and field representatives are available for consultation within each region. GS inspectors may make job -site inspections on all projects where a GS Full Value Roof Membrane Warranty is requested and application is approved prior to the installation of materials. • WESTERN REGION 2155 Las Positas Cr. Suite V Livermore, CA 94550-9583 (510)606-7434 (800) 955.08// FAX (510) 606 -1097 - - 1 gm mos Roofing GS REGIONAL SALES OFFICES ❑ EASTERN REGION 5525 MacArthur lllvd. Suite 900 Irving, TX 75038 (214) 580 -5604 (800) 333 -7663 FAX (214) 580-5692 G R P -3004 ACCESS ROOFING 8/18/99 City of Tukwila Building & Planning 6200 Southcenter Blvd. Tukwila, Wa. 98188 RE: Roofing Permit Narrative To whom it may concern, COPY I understand that the Plan Check approval` are sul)tt'ct to errors and omissions and approval of plan?, dons not authorize the viulation of any adopted code or ordinance. Receipt. of con tractor" opY of a ► proved plans acknOwled0ed. r Date Permit No. Access Roofing has been contracted by King County Housing Authority to remove the existing 3 ply roofing system, and install a new U.L. Class A single -ply roof system. The building is located at 14440 4151 Ave. So. Seattle, Wa. 98168. The roofing contract amount is $139,700.00 plus sales tax of $ 3,300.00. Sincerely, Access Roofing racici-- 0159 UDO 38+- • O LIE `.F 5L 0 pa. 4t- 0 •., (T zy c a New OdettFLow Sul.?KM- BooF 1:6(-4-ILA4NC> $G/4LE: Ye" _ roll Vd.H 5HtNtaJts 61t, 011E1-FLow S.A.Vr rR 31' 5css(,E : PITS SLoee .713 T`(P • 1 4+' CRwckicT (TYR SLope. ra DRAIN As giteN.x%Nzt. TYPicA4 GALA ' M¢*P,L. 1001 Gogi NG. `11 P, AskETEn Feamici R SQu.b.RE- APPROVED CM)) RECEIVED AUG 5 1999 KCHA MAINT /CONSTR 0 • SLo?e 3/84— L ST A.'" WALL Scal.E s Nrs • SAP MILTN stcs.r o F Asir EACH st�E NEw Ve cox ltooFiNG ME ,ExW. W00 lkAcrrg:RS .r .. Z /V ,4Ti a R/ 1Z' +- .4 SLOPE 1,0 T�( P • 1<t.k r (TYP) 51. pi. ra DOW Rg. w„Alta.b Maria c OVED ECEIVED AUG 5 1999 MAINT /CONSTR SLofE Ye: +— Y• Loral ANr-o Ti4 E (7Y1) , 414. MI:TAI.. KN . iw6 sticcrs o F ASttI aR EA• 5 NEW VS C.D)C pt(WooD 'TAP WAIL SCALE? Nrs Too Fiw G ME Me114NG. Wo op T÷FT �L ,� ,• TYPICAL 1RooF(NG <LAss A E c .— ail` SivSarL,aTiO4) 77P> NTS (-roc P) RECEIVED GTY OF TUKWILA AUG 1 8 1999 vr PERMIT CENTER GTA /FR MFtAZRANE GZ )=Ase SNRR7"(.Z) New Th?ER =N54LATODN 15* - Zu.I .UM . PAPC14. %IF eoR DRRw ER 5/8 COX SiraRTtkiNG 1 Q 0 :. rt '.:t ,'. W" iia �i? 1 uaSlnee'wi ulb' trfNii ail: ' ° N'rV iw ti Y.,4 f i 4 YPwy?P Ntir'F?iAp{1s{::�iF ACCESS ROOFING May 12, 2000 Department of Community Development 6300 Southcenter B 1, #100 Tukwila, Wa. 98188 RE: Riverton Terrace Apartments To Whom it May Concern, Access Roofing has installed a roof membrane assembly, including insulation, consisting of Atlas tapered polyisocyanurate insulation, GS splecification GTA -2 -3, Data sheet enclosed, which meets or exceeds the requirements for class B roofs. This roof was installed at 14471 41 ave S., under city of Tukwila permit No. M199 -0161. Thank You, Rick Nesheim Access Roofing May 5, 2000 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Rick Nesheim 924 N 143`d St Seattle Wa 98123 RE: Permit Status MI99 -0161 14471 41st St Dear Mr Nesheim: In reviewing our current permit files, it appears that your permit for a re -roof, issued on August 26, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, GAS QQ44,A, Bill Rambo Permit Technician Xc: Permit File No. M199 -0161 Duane Griffin, Building Official C Px-ryJ Cood. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M199 -0161 DATE: 8 -18 -99 PROJECT NAME: RIVERTON TERRACE APARTMENTS /RE -ROOF XX Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # — Revision # _ After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention n Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 8 -1 9-99 Not Applicable TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions DUE DATE 9-16-99 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: WRROUT[.DOC ,•(IM17s14K)tyFto A, fr..::•••.:•c• ,, ,s,..,∎ .w..%•47 .., MASTER LICENSE SERVICE REGISTRATIONS AND LICENSES STATE OF WASHINGTON UNIFIED BUSINESS ID 0: 601 451 980 BUSINESS ID 0: 001 EXPIRES : 03 -31 -2000 ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION ACCESS SERVICES INCORPORATED 924 1 143RD SEATTLE WA 98133 DOMESTIC PROFIT CORPORATION RENEWED BY AUTHORITY OF SECRETARY OF STATE REGISTERED TRADE NAMES: A R SUPPLY ACCESS ROOFING AND CONSTRUCTION ACCESS ROOFING LEAK REPAIR SPECIALISTS The above entity has been issued the business registrations or licenses listed DEPARTMENT OF LICENSING, BUSINESS & PROFESSIONS DIVISION, P.O. (30X 9034 OLYMPIA. WA 98507.9034 (360) 664.1400 RI' \II:;N'I' OF I..: \li()I :\ \I) I:NI) UST I∎INS REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 ACCESRI071D6 05/01/2000 EFFECTIVE DATE 03/26/1993 ACCESS ROOFING INCORPORATED 924 N 143RD SEATTLE WA 98133