Loading...
HomeMy WebLinkAboutPermit MI99-0181 - FIELDS ROOF SERVICE - REROOF�"ix''.1i' /l'. .... : »R .'!l•;yR`�`.';. ?�."r„'al'�X�..: Ll:�t:'$:'.'.' :r�l'(1: MI99 -0181 6519 so. 153x° St. Field's Roof Service City of Tukwila ( (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 295490 -0352 Address: 6519 Si 153 ST St: LAND Suite No: Location: Category: NSFR Type: MISCPERM Zoning: MDR Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: Permit No: Status: Issued: Expires: MI99 -0181 ISSUED 10/12/1999 04/09/2000 Occupancy: DWELLING UBC: 1997 Fire Protection: SMOKE ALARMS .0 South: .0 East: .0 West: .0 Sewer: N/A Slopes: Y Streams: Contractor License No: FIELDRS262L1 OCCUPANT OWNER CONTACT CONTRACTOR FIELD'S ROOF SERVICE 6519 S 153 ST, TUKWILA, WA 98188 HEINZ ELEANOR L 6519 S 153RD AVE, TUKWILA WA 98188 MIKE BURNS 25924 78 AV S, KENT, WA 98032 FIELDS ROOF SERVICE INC 25924 78 AV S, KENT, WA 98032 **************************•***************• k************ * * * * ** * ** * * * * * * * * * *** * ** * * *'k ** i Phone: Phone: 253- 852 -4974 Phone: 253 -852 -4974 Permit Description: TEAR OFF AND DISPOSAL OF EXISTING BUR ROOFS, COPINGS, VENTS, SKYLIGHTS. INSTALL POLYGLAS 202 PS ROOF SPECIFICATION. (G -2 BASE, MODIFIED BITUMEN MEMBRANE, REFLECTIVE COATING). NEW COPINGS, VENTS SKYLITE. ****** k********************************************** * * * * * ** * ** * ** * * * * * * * * * * ** * * *k ** Construction Valuation: $ 5,280.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: • k***************************************************** * * * ** * * ** * * * * * * * * * * * * * * * * * *** *. TOTAL DEVELOPMENT PERMIT FEES: $ 116.75 ****************************************************** * * * * * * * * * ** * ** * * * * * * * * * * * * * ** *, Permit Center Authorized Signature: tc, Date: ID—VD-99_ L I hereby certify that I have read and examined this permit and know the sane to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit Signature: Print Name: _11 cam_ - miNS_ Date J6_tz -�-� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 1 OF TUkiAtii.A. ddre.s.s: 6519 S 153 ST St: LAND, . • ienant: YybezNISCPERM. In,acoel 295490-035,7' Permit, No: 1199-6:r31 Status: ISSUED. Aoplied: 10/EW1999.. issued: lOi12/1999 '4 h*4*le k *#,A4 k A4*A4*-0, 48.4e 4f4e:44 b k 4 4,.k.h* Or A. f 4 k* * h k444.6 k N1,4, A A,* 44/. 44/. 4 .1( kA k k 444 Perm“. Conditions.:• . • • I, 6/0, OyahOes wi)/ be Made to the plaoS .apbroiied'..by the En' ;eer and the Tukwila,..B01,0401:14,0A0s.j•on; cohstruotiOn to:beHdOheihHOOh'folijai4c0:10.)th•aPProYed•.... sdans'a6d requirPm6iit.:SOf the U) 11 *1997.., tdit:iOn) aSameh:d€0..- LInlIO'rm:HeohhiOalcode.J199Z Edttiohl. 3, :Validity t n * Th iSstfroce ot MA.t.oy..apl.iroval of ahs. speofficatfohsand oompUtatiohs, .-strUed 'PerMft forYOr an.;:..47.prOAfal 01 Woy*v,iojation of any/OfitheprO‘iiSlohs c the iu Id i oOdeor 0ther..ordinance.ofthe jurisdiOttob, No.perMAt.:prestiMihgto .9iveauthority to':-.violate-Or.Oanoelthe ProviSioni'of oodeShail.be -valid. 4, AlLper0t*,.:.inSpectfori recOrOsand approved plans.-Shli avaiijabje at the tob:SIte pr.)or to the start of aoy cOn•-• . :.stvji3OtiOn,,::..These.documehtS*,Are tO.:.be,mathtained.a6d abjeuntil flhal jospect.ion•appro%;al: '.r ar1et1 . • :11.? Of. Fijkwii_4 PEROOF CONDITIONS t(1 I4c. MI'9-01E,1 Name: FIELD'S ;ROOF SERVICE Addre.ss: GE 1 15.1 Si St: LAND .....•'" 441,-FAikykkAh*bk4kkkkhAkhkkA4kithiGA ',4.4h,(**Ahhe,***A-AkkfrieklykkA*khA4tikb THE FOLLOWING CONDITIONS:WiLLAPPLY TO RE-ROO'F:FERMITS':. 1. All re-rOofing protects will be accompliShed. in COMpliance with Appendix : Chapter 15 of the Uniform BuildingHCode (OBC). Inspections: rOof coverings shall not be applied without first:: ':o0tainin9 a pre-...roofing inspection from the.E501ding. friviston and written aPorovai.from the BuildingInspect,or. the pre-,roofing inspeCtion shall pay particular attentiOn to evidence of accumulation of water. Where extensiVe pondin9 U7 water is apparent.. an analysis of-the roof strUcture :.for compliance With Section 1506, UBC. shall be made and corrective measures. such as relocation of roof •dralns.:,Or • sCupper s. re sloping of:The roof or structural changes..:snair he accomPlished. ?,n inspection...cOvering the abOVe,Aisted N. PrePare0 6, a gbalified. speciaT.inspeCtoraS deterMined by. the Building'Official. may be:acCeoted.,61: lieu of the pre-inspection by the BUAlding IhspeCtdr'., B. A.final inspection and approv al Shall be Obtained from the BUilding Division when the re-roofing comOlete,As a condition...of the final inSpectionfortooshatxr.equire a T ire retardant r001*. covering under the prOlsionS,of Table 1994 UB1 . the roOf.Anstaller shall'Orovidehe inspector with a writt.en statement 1nd1cat1n44he following (or sOmething irni I: .1 HAVE INSTALLED A ROOHMEMBRANE ASSEMBLY.. OCLUDINGIINSULATION IF APPLICABLE. CONSISTING OFJMANPFACTURERSPECIFICATION # uArp SHEET ENCLOSED WHICH MEETS OR E)'e,CEEDSTHC'REOUIREMENTS FOR CLASS A OP CLASS 1 ROOFS, THIS ROOF WAS INSTALLED AT (ADDRESS):. :UNDER CITY OF TU(WILA PERMIT NO, flie statement shall include the name of the roofin9 company that installed the roof. sinature 01 installer and date.) " • CITY OF IKWI LA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: R STAI I USE ()NI Y r'Vzq51 - of 81 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name /Tenant: . :, trarA . 4 (et- PI� Applj t';tken by: (Initials) may„/,/~ s (20C1 SYV(cZ, Value of Construction: Yi s'.? % C) . 0 0 Site Address : 4s1°t 15.�cc.` -s ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks � _.mmercial Reroof ❑ Demolition ❑ Fence Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting City State /Zip: 7,,,k.w,l(4., T P 045 -o�sa Property Owner: { Cu.rJ L- , \\"NeS:, City /Sta e /Zip: • Phone: (2C4, ) s t_( C, - 1-7 a" 1 Street Address: 0 Metro 0 Standby City State/Zip: Fax #: ( ) Contractor: ,.•P.�, c.�s `J�c�ti;.e _ �T.L Phone: (. S3 ) 8 s 2 - t_( cl -7 / Street Address: .1G c., '18 I Q4-. Se. City State/Zip: `- e..r.� W 1} 9 a...)3'L. Fax #: (G-' ) .. i) S-3 S S Z - c(oi cc Architect: Phone: ( ) Street Address: City State /Zip: Fax #: ( ) Engineer: Phone: ( ) Street Address: ,... , City State /Zip: Fax #: ( ) Contact Person: 61. • 'qj kr w C _ ,o_ _d 7 V_ea 0 Cs-- e..c'' •) Phone: (2S3) g .5-. -c-L el -7 -y 42-X-k- 2.1 Street Address: �,, 4-L&ors - '). < t 3-' ( -7 $4 `{! J•t S c. City State /Zip: V-e_ -'t (r/ el- ci N037.-- Fax #: (z5-?_, ) 1sS 2 -LI c:,ot Q MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Date'appJicatipq expi. , (` -( /.�- 1/ ( Applj t';tken by: (Initials) may„/,/~ Description of work o be done (please be specific): ' 1 eC� - chg. G G In c-. rJ ',, ? o� G U �r Q.& 1 -k!• C ,,,.� C G 0 r c<. (, N'I.` 3, 11,.., 4% 1 S t:..,` 1 i'e S .1.r, S E.11 1>o (c, G (c.,,' 2-('12 12 S R--,c( S .t= L ‘ �'- (C. c - i' , c, �n • CG, ----2_ c.,,...-i.0 i 61 0 CA l � t L' C.) - t"!, k rr■LYL mm�c,A(e / 2e.( -lac_ -Iij t .O ( # iv,. € ,J C_c3 ? 'v.� S ) d e,..•F r S' K 4''� e , Will there be storage of flammable/combustible hazardous material in the building? ❑ yes no Attach list of materials andstora :e location on se.arate 8 1/2 X11 •a•er indicatin: .uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead /Docks � _.mmercial Reroof ❑ Demolition ❑ Fence Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting Address: APPLICANT RE • UEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS • Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent # ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 _sq. ft.grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public El Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): _ Est. quantity: gal Schedule: U Moving Oversized Load /Hauling MONTHLY SERVICE BILLINGS. TO: Date'appJicatipq expi. , (` -( /.�- 1/ ( Applj t';tken by: (Initials) may„/,/~ Name: Phone: Address: City /Sta e /Zip: • 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /Sta e /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed possible revision by the Permit Center to comply with current fee sciedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. and is subject to by limitation. The applicant as defined Date apFlicat(on accepted: 1 U II o Date'appJicatipq expi. , (` -( /.�- 1/ ( Applj t';tken by: (Initials) may„/,/~ AI.1 MISCLIIAN(OUS P.• • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED • ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT D STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ SUBMI1 APPI I('A1ION AND RFQt1IRFI) (1IE( IU ISIS 1 OR Above Ground Tanks /Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PF RMI1 RI VIE W Submit checklist .No: M -9 ❑ Antennas /Satellite,Dishes Submit checklist No: M -1 ❑ Bulkhead /Dock Submit checklist No: M -10 rY 1 Commercial Reroof Submit checklist No: M -6 ❑ Demolition Submit checklist No: M -3 ❑ Fences - Over 6 feet in Height Submit checklist No: M -9 in Land Altering/Grading/Preloads Submit checklist No: M -2 ❑ Miscellaneous Public Works Permits .Submit checklist. No: H -9 ❑ Manufactured Housing (RED INSIGNIA ONLY) Submit checklist' . No: M-5' ❑ Moving Oversized Load /Hauling SUbmit checklist No M -5: 0 Parking Lots Submit checklist No M -4 ❑ Retaining Walls - Over 4 feet in height Submit checklist No: M -1 ❑ Temporary Facilities Submit checklist No: M -7 ❑ Tree Cutting Submit checklist No: M -2 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Fain H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other thaii•the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the,property owner authorizing the agent to submit this permit application and obtain the permit will be required as part.of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O UTHO D AGENT: Signature: ` .------ Date: 10 / (i tq`�. ION Print name�-� `_Lk ` \ r4`� Phone: (2 ) �SZ_ i c(-1 ti Fax #: (2S3) 52 -c(q qg Address: City /State/Zip: CITY OI TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 M -6 Submittal Checklist Miscellaneous Permits REROOFS RESIDENTIAL REROOF: Single- family structures are exempt from reroof permitting unless roof structure is to be repaired or replaced, in which case a Residential Building Permit is required: COMMERCIAL REROOF: If roof structure is to be repaired or replaced, a commercial building permit will be required. Req'd N/A Document Requirements Narrative describing existing roof, material being removed, and material being installed. Pre - roofing inspection required by U.B.C. Appendix 1515.2.1. 1. 1994 Washington State Non - residential Energy Code requires documentation showing roof insulation conforms with W.S.E.C. Section 1132.1 Exception #6. Documentation must verify one of the following. a) The subject roof is currently insulated or conforms otherwise with the W.S.N.E.C. b) The r f will be insulated to conform with tl a required W.S.N. E.C. R- values. 2. Roofing manufacturer's specification and listing for fire retardant rat ng. 3. U.B.C. APPENDIX SECTION 1516 - BUILT -UP ROOFS: 1516.1 General. Built -up roof covering shall be completely removed before applying the new roof covering. New roofing conforming to Section 1503 shall be applied except that when the new roof is to be applied directly,to a nailable deck which has residual bitumen adhering to it, a rosin -sized or other dry sheet shall be installed prior to the installation of the new roof system. EXCEPTION: The building official may allow existing roof coverings to remain when inspection or other evidence reveals all of the following: 1) That the roof structure is sufficient to sustain the weight of the additional dead load of the roof covering. 2) The roof deck is structurally sound. 3) Roof drains and drainage overflows are sufficient to prevent extensive accumulation of water. 4) The existing roof covering is securely attached to the deck. 5) The existing insulation is not water soaked. 6) Fire - retardant requirements are maintained. NOTE: A certification letter is required prior to final inspection and sign -off of the permit. `ti..rw ,Jt 7FF°:7 t' r7777 777711777777.17777r777" T.^.`;R-;7 • ****** ** *** * * * * * * ** * * * * *** ** *** * * * * * * ** * ** * * * * * ** * ** *** * * * * *** CITY OF ******A, ** * * * * * * ** * ** * * * * * * * * * * * * * * * * * * * * ** TRANSMIT Number: R9800164 Amount: 116.75 10/11/99 1.3:06 Payment Method: CHECK Notation: FIELD'S ROOF SER Init: TLB SIT WA 0 Permit No: MI99 -0181 Type: MISCPERM MISCELLANEOUS PERMIT. Parcel No: 295490 -0352 Site Address: 6519 S 153 ST St: LAND Fir Uri: Total Fees: 116.75 This Payment 116.75 Total ALL Pmts: 116.75 Balance: : .00 ********************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** .Account Code Description Amount 000/322.100 BUILDING - RES 112.25 000 /386.94 STATE "BUILDING SURCHARGE 4..50 • INSPECTION NO. INSPECTION'RECO( Retain a copy with permit CITY OF TUKWILA BUILDING DIVIION 6300 Southcenter Blvd, #100, Tukwila, W981 -88- Migq-0181 PERMIT NO. (206)431 -3670 'e %dls / "f)l 5,146(z_, TAI n ion: (p5 /c 5 /55 Si- • Special instructions: D. hgdio l m. P.m. Re�questerk:, 1"'t k IOC- Phbot. ,g, 5 g.. ill -Ai Approved per applicable codes. fl Corrections required prior to approval. COMMENTS: ro FL-7 47.00 REINSPECTIPN FEE REQUIRED,/ Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. all to schedule reinspection. Receipt No: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit h/431q-oigt CITY OF TUKWILA BUILDING DIVISION � 6300 Southcenter Blvd, #100, Tukwila, WA 98188 \'4 (206)431 -3670 PERMIT NO, Ptforep:r r ,, 1 t 1 i-e1•. ii' T pe- f Inspection: t., roo4" C' P D r /, ..._(- A dress,•,,. D to called: ig tell •-t T C ..-L.-7- ,-,4 Special instructions: Date w0a ted / q I la.m. Rrie/ti,tpd • .. . a ° - pp (2c Approved per applicable codes. Corrections required prior to approval. COMMENTS: C' P D r /, ..._(- --� c 4 ftz 4-36-471 A-lo r •-t T C ..-L.-7- ,-,4 OAP /7).5-A.1,..3 , r c vi,e._4> 4r /:,.-% , • 7 / 7i 41 s Da7 J %9 E $47.00 REINSPECTION EEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, CaII to schedule reinspection. _ Ins • -, •r• 200 SERIES SPECIFICATIONS POLYFLEX (APP) SMOOTH, 1 LAYER & 1 BASE SHEET - NEW OR REROOFING ROOF COATING (ASSPECIFIED) ELASTOBASE (OR G2 TYPE BASE SHEET) MECHANICALLY FASTENED TO ROOF DECK ACCORDING TO FACTORY MUTUAL REQUIREMENTS APPROVED ROOF DECK/ SUBSTRATE (OR ACCEPTABLE EXISTING ROOF) POLYFLEX (TORCH APPLIED) FACTORY MUTUAL APPROVED FASTENERS 8 FASTENING PATTERN PART 1 - DESCRIPTION Provide all ,.labor, materials, equipment, supervision and incidentals as needed to install a complete POLYGLASSTM reinforced modified bituminous roofing system over a new or approved, prepared existing roof substrate. All details of installation shall conform to "POLYGLASST„ Specifications, Details and General Recommendations." QUALITY ASSURANCE 1. Products used in the work of this Section shall be manufactured by POLYGLASSTM or approved for use in conjunction with the products manufactured by POLYGLASSTM. 2. The Roofing Contractor and his personnel shall be currently approved by POLYGLASSTM as qualified to install the materials of this section. 3. Do not apply roofing during inclement weather. Do not apply roofing membrane to damp, frozen dirty, or dusty surfaces. PART 2 - MATERIALS BASE SHEET - POLYGLASSTM modified bituminous base sheet, reinforced with a glass fiber mat and weighing approximately 80 pounds per roll. There are approximately 200 square feet of finished base sheet coverage in each roll. Tradename: ELASTOBASE ROOFING MEMBRANE - POLYGLASSTM modified bituminous roof membrane reinforced with a polyester mat, Top surface of membrane is sanded. This material is packaged in a roll providing approximately 100 square feet of finished roof coverage and weighs approximately 90 pounds. Trade name: POLYFLEX MI99 -o181 mECEIVED CITY OF TUKWILA OCT 1 1 1999 PERMIT CENTER ASPHALT PRIMER - Meeting ASTM D 41 specification, applied in strict conformance to manufacturers recommendations. COLD PROCESS ADHESIVE (Where specified) - Follow the instructions of the adhesive manufacturer with regard to storage and installation requirements. FASTENERS - Unless otherwise approved by POLYGLASSTh, or specified by the architect, shall consist of fasteners and plates of the size, type and quality required for FM Approval, SURFACE COATING (Where required by specification) - emulsion coating, asphalt latex emulsion roof surfacing material, asphaltic based aluminum roof coating (fibrated or • non - fibrated) or a colored acrylic coating, may be required to meet necessary fire code approvals. Consult POLYGLASST,,, Technical Service Department for fire rated assembly information. PRODUCT HANDLING All materials, except those that are shop fabricated shall be delivered to the job site with their original-labels intact. Bulk materials shall be identified by the manufacturer as to specification issued. All materials shall be stored in accordance with the instructions of the manufacturer prior to their application or installation. No wet or damaged materials will be used in the application. Materials stored on the job site shall be a minimum 4" off the ground or the roof. Application of all roofing shall be accomplished in such a way that each area will be complete at the end of each days work._ All roof edges and incomplete flashing shall be protected against water entry, particularly between work periods. ww■ •1/011_.• ALT ALL Mk Mb w► When ambient temperature is below 40 degrees F, care must be exercised in handling and storing POLYGLASST„ membrane. Only rolls for immediate application shall be exposed to the elements. All masonry, concrete and sheet metal surfaces incorporated into the roof system shall be primed with asphalt primer meeting ASTM D 41 specification and allowed to dry prior to installing bituminous roofing materials. Wood curbs or nailers, where required, shall be pressure treated with approved pressure treatment meeting AWAP Standard P -S; PART 3 - APPLICATION PREPARATION The roof surface which is to receive the POLYGLASSTM, roofing system shall be smooth, clean, free from loose gravel, dirt and debris, dry and structurally sound. FOR REROOFING APPLICATIONS; 1. Remove existing roof fleshings from curbs and parapet walls down to the surface of the roof. Remove existing fleshings at roof drains and roof penetrations. 2. Remove all wet, deteriorated, blistered or delaminated roofing membrane or Insulation and fill In any low spots ocolirring as b result of removal work to create a smooth even surface for application of new roof membranes. 3. Existing roof surfaces shall be primed as necessary with asphalt primer meeting ASTM D 41 specification and allowed to dry prior to installing the POLYGLASSTM roofing system. INSTALLATION Decks: prime where required, in accordance with requirements and recommendations of the primer & deck manufacturer (if applicable), MEMBRANE: Directly over the prepared /primed deck install ELASTOBASE, or alternatively a Type G -2, glass fiber base sheet, with minimum 3" side laps and 6" end laps, without wrinkles or fishmouths. The base sheet shall be fastened with Factory Mutual approved fasteners, appropriate for the specific deck type and thickness. Length to be as recommended for Factory Mutual required penetration of layers and deck. Alternatively; Install base sheet in a full coating of approved cold adhesive (see MATERIALS section above), in accordance with the adhesive manufacturer's recommendations and installation instructions. Directly over the ELASTOBASE install one ply of POLYFLEX. Sheets shall be set with min. 3" side laps and min 6" end laps. The rolled membrane sheet shall be set and. unrolled approximately six feet to align sheets: A propane torch flame shall then' be applied to the exposed, outer surface of the roll (the membrane underside) until the surface reaches the proper application temperature " (generally 350 to 400 degrees Fahrenheit). The roll Is then gradually unrolled to create a continuous heat weld between the membrane and substrate. The remainder of the roll is re- rolled and installed in the same manner. There should be approximately 1/4" to 3/8" bleed out crf the melted membrane backing adhesive at the overlaps. The laps shall be top rolled using a six inch wide roller applying pressure over the laps immediately after heat weld is completed. All overlaps shall be checked and sealed. At all locations where the lap is not sealed, a trowel shall be used to open the lap, heat is to be applied with the torch into the lap to melt the adhesive (on the back of the top roll) and seal the lap. Any area where a satisfactory re -weld cannot be achieved shall have a piece welded over,it, extending min 6" in all directions beyond the unwelded seam. The rolls of membrane shall be installed perpendicular to the slope of the roof, starting at the lowest point of application, wherever possible. Laps of sheets should be installe' so as to shed water with the slope of the roof wherever practical. At any intersection between different roof slopes, narrow valleys or gutters (less than 3' wide) or similar details, install an additional ply of smooth POLYFLEX under the cap sheet, extending minimum 3" onto each surface. FLASHINGS The flashing shall be installed using POLYGLASSTM, flashing sheets and min. 6" wide POLYGLASSTM stripping sheets. The stripping sheet shall be installed with a minimum' of three inches in both the horizontal and vertical surfaces. The flashing sheets shall be installed with a minimum of six inches on the horizontal surface and extend a minimum of eight inches above the finished roof surface. The flashing sheets shall be installed by the same heat weld method used for the roof membranes. The top edge of the flashing sheet shall be secured using a termination bar (only when the wall surface above is waterproofed), or nailed 4" on center and covered with an approved counter flashing. Items related to reroofing operations such as sheet metal gravel stops, roof vents, and similar items shall be incorporated into the new roof system in accordance with the recommendations described in the current issue of the POLYGLASST,,, "SPECIFICATIONS AND DETAILS" manual. APPLICATION OF SURFACING Roof coating shall as applied as the surfacing material over the membrane, as required by the specifier. Application of coating shall be in accordance with the recommendations and specifications of the coating manufacturer. nor.' •wtc! cAt • RECENID CITY OF TUKWILA OCT 1 1 1999 PEhivil -.q City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director September 5, 2001 Mr. Mike Burns 25924 78 Ave. S. Kent, WA 98032 RE: Permit Status MI99 -0181 Site Address: 6519 S 153 St. Dear Mr. Burns: In reviewing our current permit files, it appears that your permit for removal and replacement of existing roof at Eleanor Heinz residence issued on October 12, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, kc tttc(41 /Ua )1(110.1-0-1- Kathryn A. Stetson Permit Technician Xc: Permit Pile No.;; M11994/1$.1...4 Duane Griffin, Building Official City of Tukwila Department of Community Development 6300 Southcenter Boulevard # 100 Tukwila, Washington 98188 Re: Permit MI — 99 — 0181 6519 South 153rd Street To Whom It May Concern: Fields Roof Service, Inc. has installed a roof membrane assembly, consisting of PolyGlas Spec # 201 PS, which meets or exceeds the requirements for Class B roofs. This roof was installed, at 6519 South 153' under City of Tukwila Permit No. MI- 99- 0181 ... Sincerely, K\'3a) Mike Burns 25924 -78th Ave: So. • Kent, Washington 9802 • 200'852-4974 (206):952 = 3744`` May 5, 2000 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mike Burns 25924 78th Ave S Kent Wa 98032 RE: Permit Status MI99 -0181 6519 S 153`d St Dear Mr Burns: In reviewing our current permit files, it appears that your permit for a re -roof, issued on October 12, 1999, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)433 -7165 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician Xc: Permit File No MI99.0181 Dunne Griffin, Building Official Ps( ryi aDOYA, CrIP� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI99 -0181 DATE: 10 -11 -99 PROJECT NAME: FIELD'S ROOF SERVICE XX Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # _ Revision # _ After. Permit Is Issued DEPARTMENTS: Building Division � Iai% Public Works Fire Prevention Structural Planning Division Permit Coordinator si DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -12 -99 Complete Incomplete Not Applicable Comments: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: VLo l j DATE: (O' ( -4149 APPROVALS OR CORRECTIONS: (ten days) Approved DUE DATE 11-9-99 Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: \PRROUTE.DOC Sent By: FIELDS ROOF SERVICE; 10111 '99 12:35 I D =LAN I ERFF��.:s40 Department of Labor & Industries Contractor Registration Sadao PO Boat 44450 Olympls WA 985044450 2538524999; FM: Oct- 12- 99,.2:25PM; Page 2/2 C:.. PAGE 1 REGISTRATION VERIFICATION TEMPORARY (360) 901.5226 FAX (360) 902.5224 From Olympia Raelpanets :;..�" ._ - ,1i C36 q `S e. N v t '& = tom_ ... _ �._ jiiauion expires `..r"' \ ty l.. D R S 000:. L. k q - $ c.J clo J Contractor: Your Certificate of Registration will be sent from the Olympia office and should be received within 2 to 3 weeks. Please keep this record until you receive your Certificate of Registration. P625.0364:100 ref/Ionian verification 2.95 CUPP WWI 1- ��.- CO Thor* you