HomeMy WebLinkAboutPermit MI99-0203 - US WEST WIRELESS - BOW LAKE - MONOPOLE AND ANTENNASMI99 -0203 18700 Orillia Rd. S. US West Wireless- Bow Lake City of Tukwila (• (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: 352304 -9037 18700 ORILLIA RD Si OTHR MISCPERM TVS 000 North: HIGHLINE Contractor License No: Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: .0 South: .0 East: .0 West: Sewer: SEPTIC Slopes: Y Streams: MI99 -0203 ISSUED 01/18/2000 07/16/2000 .0 OCCUPANT US WEST WIRELESS -BOW LAKE Phone: 18700 ORILLIA ROAD S, TUKWILA, WA 98188 OWNER KING COUNTY REAL PROPERTY DIVISION, 500.KING CO ADMIN BLDG, SEATTLE WA 98104 CONTACT CATHERINE TOLOSA Phone: 425 - 652 -2132 450 110 AV NE, #209, BELLEVUE WA 98004 *** * *•Ak•k*kk *k *•k*•***** sir******************* k******• k***** * * ** ** ** * ** *********•k ** ***k** - Permit Description: INSTALLATION OF 60' MONOPOLE & 2 ANTENNAS. ADDITIO NAL EQUIPMENT TO BE INSTALLED AT BOTTOM OF POLE. ******• k*************• k************************* k****** * * ** ** * * ** *** * * *****k* * ** *** * *4 Construction Valuation: $ 50,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut/Access/Sidewalk/CSS: N Fire Loop Hydrant:. N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: .Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: **********• k****************************************** * * * *** ** * * * * ** * * ****** *** ** ***A TOTAL DEVELOPMENT PERMIT FEES: $ 952.84 k**************** ** ** * * * *** * * * ** *k *** * ***k* *k *1f ****• k** ***** *****k * ** ***•k* * * ** *** * **4 Permit Center Authorized Signature:! Date _LAL10i I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development ermit. _ C Signature: Print Name: Oa-1 �I1 the Tp /() -r6acot- Date: i/010 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 18700 ORILLIA RD 5 Tenant: Type: MISCPERM Parcel #: 352304-9037 Permit No: MI99-0203 Status: ISSUED Applied: 11/09/1999 Issued: 01/18/2000 l*Ak*Akk*k*****.AAAA*WAA*A*k**111(kk*VAllik**ki*****kk**4.*kk**kA*4,AiA*14kit*A*A* Permit Conditions: 1.. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- struction. These ,documents are to be maintained and avail- able until final inspection approval is granted. 3. Electrical permits shall be obtained through the Washington State Division, of Labor and. Industries and all electrical work will be inspected by that agency (248-6630). 4. Plumbing permits shall be obtained through the Seattle-King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296-4722). 5. All mechanical work shall be under separate permit issued by the City of Tukwila. 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 7. Validity of Permit. The issuance of a permit or approval of •plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 3. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first 'building inspection. Copies of all sPecial inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name, permit number and type of inspection being performed. 9. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with approved plans and specifications and the applicable workmanship provisions of the UBC. 10. All structural concrete shall be special inspected (UBC - Sec. 306(a)1). CITY OF T( :WILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: STA! I US! ONI Y MI�i9- 0-o3 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Project Name /Tenant: US WIC W \ e I.- 5wt,) L _A T�av► s SAO( 0 V Valu of Construction: 4.60 000 Site Address : City State /Ziy_: 2-100 U ri i l is Rc' - S S. 1TUKw>< lc� wFt cl�l$� Tax Parcel Number: 3� 2 3U4 G 03_ Property Owner: k kki\C CouV -t o Phone: ( ) 1-0b 2e1b•' -w Street Address: "So( Ki Vg Coonf N (\ ckim vd 1dc,‘ sot Sw i oLt Fax fl: ( ) Contractor: Phone: ( Street Address: City State/Zip: Fax #: ( ) Architect: 4%.pC, PcircV Iec+ I Prgi-neer 0 Standby Phone: ( ) 4125 630- X651 Street Address; (� St S u �4b.Z0 20o LEI Cit St to /Zip: o �i$� Fax #: ( ) Phone: ( ) Engineer: Street Address: .. , City State /Zip: Fax #: ( Contact Person: CCathe7rlV1e1 Tole Phone: ( ) 25 Z(32 4' G'2_ Street Address: City State /Zi ��D i10�" ���, f� Z0�� gellevu U Fax #: ( ) 42� 1Is-1 - 6510 . MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): \ ns n11ck soh 'f hO monopol-e v\ 1h 2. aniennCAS i \iup rev-4 ;) be lixceIfd at bsr build1'in �f � I Will there be storage of flammable /combustible hazardous material in the building? ❑ yes P no Attach list of materials and stora e location on separate 8 1/2 X 11 aper indicating quantities & Material Safety Data Sheets ❑ Above Ground Tanks Antennas /Satellite Dishes Bulkhead /Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ❑ Manufactured I- lousing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting APPLICANT REQUEST FOR MISCELLANEOUS PUBLIC WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Perrnanent 11 ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Land Altering: 0 Cut_ cubic yards ❑ Sanitary Side Sewer 11: ❑ Street Use ❑ Water Main Extension Size(s): Size(s): ❑ Fire Loop /Hydrant (main to vault) #: O Fill_ cubic yards 0 `sq. ft.grading/clearing ❑ Sewer Main Extension 0 Private 0 Public 0 Private 0 Public O Deduct 0 Water Only Size(s): Size(s): Est. quantity: gal Schedule: ❑ Moving Oversized Load /Hauling MONTHLY SERVICE BILLINGS TO: I' atiorj.cepte �i Date a Name: Applic o Phone: Address: City /Sta e /Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER METER DEPOSIT /REFUND BILLING: Name: Phone: Address: City /Sta e/Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date a I' atiorj.cepte �i Date a mint ntpir Applic o ken by: (initials) i ALL MISCELLANEOUS PL/l IT APPLICATIONS MUST BT SUBMIT WITH TIII IOLlOWING: > ALL DRAWINGS SHAL!BE A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED > ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT D STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER D CIVIUSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building,Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the, property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS OR AUTHORIZED AGENT: SUBMI[ API'I I(ATION AND RIQUIRTI) ( III( KI ISIS IOR Above Ground Tanks /Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2:1 PFRMI1 RIVIFW Submit checklist No: M -9 Signature: C/ - jl Antennas /Satellite Dishes Submit checklist No: M -1 Date: it (Q J qpi Bulkhead /Dock Submit checklist No: M -10 Phone: (42) Commercial Reroof Submit checklist No: M -6 0 Demolition Submit checklist No: M -3 0 Fences - Over 6.feet in Height Submit checklist No: M -9 0 Land Altering/Grading/Preloads ,. Submit checklist No: M -2 0 Miscellaneous Public Works Permits Submit checklist No: H -9 Manufactured Housing (RED INSIGNIA ONLY) Submit checklist No: M -5 O Moving Oversized Load /Hauling ∎=" ... , Submit checklist No: M -5 0 Parking Lots ., 1' , Submit checklist No: M -4 a Retaining Walls - Over 4 feet in height Submit. checklist No: M -1 n Temporary Facilities Submit checklist No: M -7 O Tree Cutting Submit checklist No: M -2 Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building,Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the, property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS OR AUTHORIZED AGENT: Signature: C/ - jl Date: it (Q J qpi Print name: Co+ heR 11j-e� To 1 osc�, Phone: (42) 6 52_ Zia?, Fax #: (4�� q5 i- 6310 Address: 4 n 110+14 /�, ,.A N_ .0 z/,9 ,City /Sate9it 9/9/99 ndscpna.doc ,+++*+�+++*+++++^+kh++ “..4AN++»+^AA*A+++++*a+*-A*+++a*A*+* CllY or [UKNILA. NA T~ l�hNGNIT �^+A+A++A+��+*a+A+�+*V:x+�*+*A*J+�**+*+*A***+*h++A**+A*+*+A 1P.ANSMIT Numb.wr: R9800220 Amount: 9.52.84 01/18/00 11:46 ,Payment Method: CH[CX :Nottitinn: US N[ST NIK[IESS Jnit: NFR ' Permit Nor. MI99".0203 Type: MISCoEVN NISCEiLANEUnSP�HMIT Purcel No: 352304-9W.17- 8itp Ad0reos: 18700 UKIL}IA RD S Tot.;,{.Feps:� 952.84 ` Povmmht 952.84 Tutar ALL Pmtsx 95�.O4 Hillance: -O0 , v+*+**++AA+*.A++++a++*+a+*+^it«*+++*a**k+***+**+***+**11*o*A34 hcrount Code 000/322.100 000/345.830 000/386.904 Deycription 8UI|0IN8 - NONKE8 PLAN CHECK - NONUEA S7A\E 8UI|'DING SURCHARGE:. Amounh.' 574./5� 373^59 `�4.�O • INSPECTION NO. INSPECTION RECORD Retain a copy with permit f PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Projec w Lc txe _us s Type,6 l ctio • Addressr� . 1$ O(16 KL •S 11.0 Date called: o3jN-( o Special instructions: Date wane I (���� p.m. Requester;., Phone: h 06.....4 (3_ is34 Approved per applicable codes. Corrections required prior to approval. COMMENTS: / ee 7-Me hd D El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [Receipt No: 1 Date: 1 INSPECTION RECORD Retain a copy with permit IN PEC ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Project: tal . - • ...., , . a. • ..e of Inspe•A ion: _ .1/11,k i !.. l! • /0 4ciress: - \ a4 Date ca ed: ,._ ,00 2cif, 1 pea instruction s itxtx- cw„ nod n Date want 4-- 00 Requeste Pho&61 'c(5 ...talc7.45 EApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: CrE • El $47.00 REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. Date: 27/4......0.0 0 X 1 SUMMIT MANUFACTUNG, LLC 225 KIWANIS BOULEVARD, WEST HAZL ..N, PA 18201 PHONE: (888) 847.6537 E-MAIL: SUMMITCAa@EPIX.NET FAX: (888) 460-6885 WWW.SUMMITMFGLLC.COM 60' -O' 57' -6' 53' -0' 47. -6' 35. -0' 16.500' ACROSS FLATS 0 0 T/FQN iH 3/16' X 27.75' (Fy =65) (EST WT = 1.073 KIPS) — SPLICE LENGTH MIN = 29.70' -- DESIGN = 33.00" MAX = 36.30' azPAUL J. FORD AND COMPANY "TRUCTURAL ENGINEERS ..i0 East Broad Street, Suite 500, Columbus, Ohio 43215 (614) 221 -6679 Fax: (614) 221 -0166 www,PJFweb,com A N T E N N A L I S T J O B D A T A page 1 of 2 Job No. 29299 -682 Design Dote n No. SUMMR JOB #5999 Rev. No. Rev. Dote By RKT Chk'd By KJS Pole 60 -FT MONOPOLE Site SEA270 BOW LAKE TRANSFER STATION: TUKWILA, WA Owner U. S. WEST Ref. No. MPH Design 90 MPH /78 MPH + 1/2' RADIAL ICE ACCORDING TO TIA /EIA -222 -F 1996 A N T E N N A L I S T POLE SPECIFICATIONS Pole Shope Type: LOAD CASES CASE 1 90 MPH WITH NO ICE DESIGN WIND CASE 2 78 MPH WITH 1/2" RADIAL ICE REDUCED WIND WITH ICE CASE 3 50 MPH WITH NO ICE OPERATIONAL WIND A N T E N N A L I S T POLE SPECIFICATIONS Pole Shope Type: 18 -SIDED POLYGON TOP 57.50 57.50 56.00 53.00 53.00 52.00 47.50 47.50 5/8" LIGHTNING ROD (2) EMS RR33- 20 -XX_P (3) 12 -FT "T ARMS r.•'•..•�::- ',:j...T ci.� •,; ; (3) US WEST REMOTE UNIT �,.�,.. ,,f 11;,,`r'; (3) EMS RR33- 20 -XX_P _ -,', ; -'.,- .,,. -.,� r''',6'�r3y' TRI -ARM SUPPORT ASSEMBLY - r+ f'�n 3 US WEST REMOTE UNIT i 4,1 '' ' 8 ALLGON 7131.20 SECTOR 3 12 -FT 'T' ARMS , i 1 " H �;+ Taper: 0.200083 I N /FT 21.4 Shaft Steel: ASTM A607 GRADE 65 0.1875 0.2500 Base PL Steel: ASTM A572 GRADE 50 (50 KS() Anchor Bolts: 2 1/4"0 x 8' -O" LONG #18J ASTM A615 GRADE 75 A N T E N N A L I S T No. Elev. Descriotion - 1 -2 - 3 -5 6 -8 - 9-11 12 -19 - TOP 57.50 57.50 56.00 53.00 53.00 52.00 47.50 47.50 5/8" LIGHTNING ROD (2) EMS RR33- 20 -XX_P (3) 12 -FT "T ARMS r.•'•..•�::- ',:j...T ci.� •,; ; (3) US WEST REMOTE UNIT �,.�,.. ,,f 11;,,`r'; (3) EMS RR33- 20 -XX_P _ -,', ; -'.,- .,,. -.,� r''',6'�r3y' TRI -ARM SUPPORT ASSEMBLY - r+ f'�n 3 US WEST REMOTE UNIT i 4,1 '' ' 8 ALLGON 7131.20 SECTOR 3 12 -FT 'T' ARMS , i 1 " H �;+ Rotation (sway) (degrees) STEP BOLTS FULL HEIGHT. ANTENNA FEED LINES RUN INSIDE OF POL Tass0.0•000.02.04.40200•10•00rodourr 1/4' X 35.00' (Fy =65) (REST WT = 2.304 KIPS) GLE0 NOV 1 9 1999 REID MIDDLETON 1/ -3 -e BASER 2 1/4" X 33.000' SQUARE c.. El tRcLt::3 t4..1 W /(4) 2.25'i ANCHOR BOLTS ON 34.000' B.C. WITH MIN. 7' -0' EMBEDMENT INTO PIER (W /NUTS & TEMPLATE PLATE 0 BOT.) 28.130' ACROSS FLATS BASE REACTIONS FOR USE IN FOUNDATION DESIGN Nov 0 6 1999 .•• a./1 A 1I 1, MOMENT = SHEAR = AXIAL = 575 ft -kips 12 kips 8 kips 90 MPH WIND 50 MPH WIND Elevation Lateral Deflection (Inches) Rotation (sway) (degrees) Lateral Deflection (Inches) Rotation (sway) (degrees) TOP 21.4 2.740 6.6 0.846 0.1875 0.2500 3300 16.500 21.127 22.052 28.130 NO E: DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES BASER 2 1/4" X 33.000' SQUARE c.. El tRcLt::3 t4..1 W /(4) 2.25'i ANCHOR BOLTS ON 34.000' B.C. WITH MIN. 7' -0' EMBEDMENT INTO PIER (W /NUTS & TEMPLATE PLATE 0 BOT.) 28.130' ACROSS FLATS BASE REACTIONS FOR USE IN FOUNDATION DESIGN Nov 0 6 1999 .•• a./1 A 1I 1, MOMENT = SHEAR = AXIAL = 575 ft -kips 12 kips 8 kips S H A F T S E C T I O N D A T A p •ft ion Section Length feet) Plate Thickness in.) Lap S ce (in li.) Diameter Across Flats (inches) ® To• ® Bottom wo 27.75 35.00 0.1875 0.2500 3300 16.500 21.127 22.052 28.130 NO E: DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES BASER 2 1/4" X 33.000' SQUARE c.. El tRcLt::3 t4..1 W /(4) 2.25'i ANCHOR BOLTS ON 34.000' B.C. WITH MIN. 7' -0' EMBEDMENT INTO PIER (W /NUTS & TEMPLATE PLATE 0 BOT.) 28.130' ACROSS FLATS BASE REACTIONS FOR USE IN FOUNDATION DESIGN Nov 0 6 1999 .•• a./1 A 1I 1, MOMENT = SHEAR = AXIAL = 575 ft -kips 12 kips 8 kips SUMMIT MANuFACTu::3, LLC 225 KIWANIS BOULEVARD, WEST HAZLETON, PA 18201 PHONE: (BBB) 847.6537 E-MAIL: SUMMITCA@EPIX.NET FAX: (888) 460.6885 WWW.SUMMITMFGLLC.COM VOLE & FOUNDATION ANCHOR BOLTS HEAVY HEX LEVELING NUT W/ WASHER POLE SHAFT & BASE PL. DOUBLE HEAVY HEX NUT W/ WASHER 3" GAP (NO GROUT) 6" MINIMUM CAISSON LENGTH 2" CLR 12" PROJECTION FIN GRADE I I 11 TEMPLATE S AND NUT 4" CLR (12) — #5 TIES 6" C/C REM /J5 TIES 18" C/C 13' -6 ' \/ W.T. -J U 5' -0 "o _ SHAFT 2' —O" MIN LAP (16) — #9 VERT REINF FULL HEIGHT al^'\UL J. FORD AND COMPANY ;.TRUCTURAL ENGINEERS 250 East Broad Street, Suite 500, Columbus, Ohio 43215 (614) 221 -6679 Fax: (614) 221 -0166 www.PJFweb,com J O B D A T A Page 2 of 2 Job No. 29299 -682 By RKT Design No. SUMMR JOB #5558 Ch' 'd By Date 1 1 —03 -1999 KJS Rev. No. Rev. Date - Pole 60 —FT MONOPOLE Site SEA270 BOW LAKE TRANSFER STATION: TUKWILA, WA Owner U. S. WEST Ref. No. Design 90 MPH /78 MPH + 1/2" RADIAL ICE ACCORDING TO TIA /EIA -222 —F 1996 THERE ARE TWO NOTCHES ON THE ANCHOR BOLT TEMPLATES LOCATED 180' APART. THE CONTRACTOR SHALL POSITION THE ANCHOR BOLTS AND TEMPLATES IN THE FOUNDATION PER THE SUMMIT MANUFACTURING ANCHOR BOLT TEMPLATE DRAWING. NOTES: 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. CONCRETE SHALL BE AIR ENTRAINED (6±1.5%). CONCRETE SHALL HAVE A MAXIMUM WATER /CEMENT RATIO OF 0.4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH 'THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE', ACI 318, LATEST EDITION. FOUNDATION INSTALLATION SHALL BE IN ACCORDANCE WITH ACI 336, 'STANDARD SPECIFICATIONS FOR THE CONSTRUCTION OF DRILLED PIERS', LATEST EDITION. 2. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A -615 (GRADE 60) EXCEPT THAT CAISSON TIES MAY BE ASTM A -615 (GRADE 40). ALL REINFORCING DETAILS SHALL CONFORM TO 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES', ACI 315, LATEST EDITION, UNLESS DETAILED OTHERWISE ON THIS DRAWING, 3. SEE PAGE 1 FOR ANCHOR BOLT QUANTITY, SIZE, LENGTH, AND BOLT CIRCLE. 4. TOTAL CONCRETE = 12.7 CUBIC YARDS. 5. FOUNDATION DESIGN IS BASED UPON GEOTECHNICAL EXPLORATION REPORT PREPARED BY: ZIPPER ZEMAN ASSOCIATES, INC REPORT NO.: J -477 DATED: 09 -15 -1999 6. CONTRACTOR SHALL READ THE GEOTECHNICAL REPORT AND CONSULT THE GEOTECHNICAL ENGINEER AS NECESSARY PRIOR TO CONSTRUCTION. 7. GEOTECHNICAL REPORT INDICATES GROUNDWATER WAS ENCOUNTERED AT 13' -6' BELOW GRADE. 8. THE FOUNDATION WAS DESIGNED USING THE FOLLOWING SERVICE LOADS: MOMENT: 575 FT -KIPS SHEAR: 12 KIPS AXIAL: 8 KIPS 9. GEOTECHNICAL REPORT RECOMMENDS THAT' THE .CAISSON.00NTRACLOR•'QE•!�� PREPARED TO CASE THE HOLE IF NECESSARY; „�:1 ;.; ' %�`� �+ ') 1.! i ) NOTE GEOTECHNICAL REPORT INDICATES THAT UNDERGROUND UTILITIES ARE LOCATED IN THE VICINITY OF THE PROPOSED MONOPOLE LOCATION. • - 2•-x/9 CAISSO\ (DRILLED PIERS FOU\DATIO\ PJF_Pole (tm) - Monopolb Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RRT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : S U M M A R Y O F A N A L Y S I S R E S U L T S Pole Height • 60.00 ft Top Diameter • 16.500 in Bottom Diameter • 28.130 in Pole Shape 18 -Sided Polygon Splice Joint Type...: Taper shaft - Slip Joint Splice Shaft Taper • 0.200083 (in /ft) Shaft Steel Weight..: 3.376 kips POLE SHAFT PROPERTIES: Shaft Section Section Length Number (ft) Wall Thickness [t] (in) Steel Top Yield Diameter [Fy] [Dt] (ksi) (in) Bottom Slip Diameter Joint [Db] Overlap (in) (in) 1. 2. 27.750 35.000 0.18750 0.25000 65 65 16.500 21.127 22.052 33.00 28.130 POLE SHAFT SECTION MAXIMUM FORCES AND MOMENTS: Shaft Wind Wind Radial Sect. Section Load Speed Ice Elev. Number No. (mph) (in) (ft) At Base of Section I Max. Ratio Axial Horiz. Bending Actual/ Load Shear Moment Allowable (kips) (kips) (ft -kips) [Ftot /Fb] 1. 2. 1 90.0 1 90.0 0.00 35.00 0.00 0.00 5.074 8.964 7.321 10.560 150.062 494.356 0.5325 0.7578 » MAXIMUM BASE REACTIONS : 7.321 10.560 494.356 « POLE DEFLECTION AND ROTATION AT TOP AND AT HIGHEST MICROWAVE DISH ELEVATION: Wind Wind Radial Load Speed Ice No. (mph) (in) Location Elev (ft) Max. Allowable Deflection Rotation Rotation Limit (in) (deg) (deg) 1. 90.0 0.00 2. 77.9 0.50 3. 50.0 0.00 Top 60.00 Top 60.00 Top 60.00 21.448 17.746 6.617 2.740 2.272 0.846 Page 1 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Owner • Status • 29299 -682 Design No: Summit Job #5558 Engineer : RKT 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA 90 mph /78 mph + 1/2" Radial Ice U. S. West Client: Summit Manufacturing, LLC Engineering Final Design Revision: Rev. Date : Pole Height : 60 ft Pole Shape : 18 -Sided Polygon Pole Type : Taper shaft - Slip Joint Splice Pole Taper : 0.200083 (in /ft) INPUT TUBE PROPERTIES: Tube Sect No. 1. 2. Top / Splice Elev (ft) 60.00 35.00 Bot Tube Elev (ft) Wall Tube Thick Length [t] (ft) (in) Steel [Fy] (ksi) Top. Di am [Dt] (in) Bot Diam [Db] (in) 32.25 0.00 27.750 35.000 0.18750 0.25000 65 16.500 22.052 65 21.127 28.130 Slip Joint Overlap (in) 33.00 TUBE SECTION PROPERTIES: Tube Sect No. Section Weight (kips) Elev Location (ft) Diam. Across Flats (in) Wall Thick [t] (Wit] (in) Ratio Diam/ Thick (D/t] Ratio Area Ix (inA2) (in "4) 1 1.073 2 2.304 @Top @Splice @Bot @Top @Bot 60.0 35.0 32.3 16.500 21.502 22.052 0.1875 13.75 18.46 18.97 88.00 114.68 117.61 35.0 21.127 0.2500 13.14 84.51 0.0 28.130 18.08 112.52 9.71 326.3 12.68 727.9 13.01 785.7 16.57 912.0 22.12 2171.9 Total Shaft Steel Weight = 3.376 kips C�. Page 2 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Owner • Statue • 29299 -682 Design No: Summit Job #5558 Engineer : RKT 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA 90 mph /78 mph + 1/2" Radial Ice U. S. West Client: Summit Manufacturing, LLC Engineering Final Design Revision: Rev. Date : Segment Properties: Tube Segmt No. Segment Feature Location Segment Elev. (ft) Diam. Wall Across Thick Flats [t] (in) (in) [Wit] Ratio ( @ Max Segment = 10 ft ) Di am/ Thick [D /t] Area Ix Ratio (inA2) (in"4) 1. top 60.000 2. <arm [1] > 57.500 3. <arm [2] > 57.500 4. <arm [3] > 57.500 5. <arm (43> 56.000 6. <arm [5] > 53.000 7. <arm [6] > 53.000 8. <arm [7]> 52.000 9. 50.000 10. <arm [8] > 47.500 11. <arm [9]> 47.500 12. 40.000 13. top sec(2) 35.000 14. bot sec(1) 32.250 15. 30.000 16. 20.000 17. 10.000 18. base 0.000 16.500 17.000 17.000 17.000 17.300 17.901 17.901 18.101 18.501 19.001 19.001 20.502 21.502 21.677 22.128 24.128 26.129 28.130 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.18750 0.25000 0.25000 0.25000 0.25000 0.25000 13.75 14.22 14.22 14.22 14.51 15.07 15.07 15.26 15.64 16.11 16.11 17.52 18.46 13.53 13.84 15.25 16.67 18.08 88.00 90.67 90.67 90.67 92.27 95.47 95.47 96.54 98.67 101.34 101.34 109.34 114.68 86.71 88.51 96.51 104.52 112.52 9.71 326.3 10.01 357.2 10.01 357.2 10.01 357.2 10.18 376.7 10.54 417.7 10.54 417.7 10.66 432.1 10.90 461.7 11.20 500.5 11.20 500.5 12.09 630.1 12.68 727.9 17.00 986.0 17.36 1049.5 18.95 1364.5 20.53 1737.0 22.12 2171.9 Total Number of Antennae / Arms = 9 Page 3 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : ANTENNA AND ARM PROPERTIES AND LOAD DATA: LOAD CASE 1: BASIC WIND VELOCITY = 90.00 mph Arm Load Antenna Antenna Ant Mount. Applic. Arm Ice Area Force Antenna Arm Elev. Elev. Length Load [CaAa] [gzGhCaAa] Weight No. (ft) (ft) (ft) Case (sf) (lbs) (lbs) [1] 57.500 61.500 0.0000 No Ice: 0.50 20.93 108.00 Description: 5/8" Lightning Rod [ Gh ] [ Kz ] 1.69 1.195 No Ice: [ qz ] (psf) 24.773 [qz] [Gh] (psf) 41.866 [2] 57.500 57.500 2.0000 No Ice: 30.00 1232.07 1310.00 Description: (3) 12 -Ft "T" Arms [ Gh ] [ Kz ] 1.69 1.172 No Ice: [ qz ] [qz] [Gh] (psf) (psf) 24.301 41.069 [3] 57.500 57.500 0.0000 No Ice: 14.00 Description: (2) EMS RR33- 20 -XX_P [ Gh ] [ Kz ] 1.69 1.172 No Ice: [ qz ] (psf) 24.301 574.96 54.00 [qz] [Gh] (psf) 41.069 [4] 56.000 56.000 0.0000 No Ice: 15.69 Description: (3) US West Remote Unit [ Gh ] ( Kz ] 1.69 1.163 No Ice: [ qz ] (psf) 24.118 639.52 339.00 [qz] [Gh] (psf) 40.760 [5] 53.000 53.000 0.0000 No Ice: 21.00 Description: (3) EMS RR33- 20 -XX_P [ Gh ] [ Kz ] 1.69 1.145 No Ice: 842.60 81.00 [ qz ] (qz] [Gh] (psf) (psf) 23.742 40.124 [6] 53.000 53.000 2.0000 No Ice: 15.00 Description: Tri -Arm Support Assembly [ Gh ] [ Kz ] 1.69 1.145 No Ice: 601.86 290.00 [ qz ] [qz] [Gh] (psf) (psf) 23.742 40.124 [7] 52.000 52.000 0.0000 No Ice: 15.69 Description: (3) US West Remote Unit [ Gh ] [ Kz ] 1.69 1.139 No Ice: 626.12 339.00 [ qz ] [qz] [Gh] (psf) (psf) 23.613 39.906 [8] 47.500 47.500 2.0000 No Ice: 30.00 1166.61 1310.00 Description: (3) 12 -Ft "T" Arms [ Gh ] [ Kz ] 1.69 1.110 No Ice: [ qz ] [qz] [GM (psf) (psf) 23.010 38.887 [9] 47.500 47.500 0.0000 No Ica: 57.09 2220.07 127.20 Description: (8) Allgon 7131.20 Sector r 1 rR71 rr_hi L .. kin J ...._.-C ..nz. . . 1.69 1.110 No Ice: 23.010 38.887 C,.. Page 4 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner • U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : POLE SHAFT LOADS: LOAD CASE 1: BASIC WIND VELOCITY = 90.00 mph Design Loads per TIA /EIA -222 -F Standard; Gust Factor Gh = 1.69 Pole DL Overload Factor = 1 Per TIA /ETA Table 1: Note 3: For all cross sectional shapes, Force Coefficient [Cf] need not exceed 1.2 for any value of C. (Where C=sqrt(Kz)*V*D.) Top of Veloc Pole Projected Area Segment Shaft Segment Expos Press Veloc Force Shaft Segment Wind Segment Elev. Coeff [qz] Coeff Coeff [Ae] [Cf Ae] Force Weight (ft) [Kz] (psf) [C] [Cf] (sf) (sf) (lbs) (lbs) 60.000 1.186 24.60 134.78 0.650 1.383 0.899 37.38 33.24 57.500 1.172 24.30 138.03 0.650 2.106 1.369 56.55 50.61 57.500 1.172 24.30 138.03 0.650 0.000 0.000 0.00 0.00 57.500 1.172 24.30 138.03 0.650 0.710 0.462 18.96 17.07 56.000 1.163 24.12 139.93 0.650 2.883 1.874 76.58 69.31 53.000 1.145 23.74 143.66 0.650 2.950 1.918 77.55 70.93 53.000 1.145 23.74 143.66 0.650 1.500 0.975 39.12 36.07 52.000 1.139 23.61 144.87 0.650 1.517 0.986 39.34 36.48 50.000 1.126 23.35 147.24 0.650 3.083 2.004 79.31 74.17 47.500 1.110 23.01 150.12 0.650 2.356 1.532 59.97 56.69 47.500 1.110 23.01 150.12 0.650 0.794 0.516 20.06 19.10 40.000 1.057 21.91 158.05 0.650 13.268 8.624 326.83 319.37 35.000 1.017 21.09 162.63 0.650 8.819 5.732 207.49 332.62 32.250 1.000 20.74 162.58 0.650 3.588 2.332 82.07 114.90 30.000 1.000 20.74 165.96 0.650 5.507 3.579 125.44 176.40 20.000 1.000 20.74 180.96 0.650 19.440 12.636 442.81 623.11 10.000 1.000 20.74 195.97 0.650 21.107 13.720 480.79 677.13 1.000 1.000 20.74 209.47 0.650 20.422 13.274 465.19 655.61 1 Summation TOTAL = 2635.48 3362.79 ( END LOAD CASE 1 - POLE SHAFT LOADS ) Page 5 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Owner • Status 29299 -682 Design No: Summit Job #5558 Engineer : RKT 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA 90 mph /78 mph + 1/2" Radial Ice U. S. West Client: Summit Manufacturing, LLC Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- AXIAL AND SHEAR FORCES: LOAD CASE 1: Tube Segment No. BASIC WIND VELOCITY = 90.00 mph Segment Elevation (ft) Axial Load (kips) Cumulative Axial Load (kips) Horiz. Shear (kips) Cumulative Horiz. Shear (kips) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Base 60.000 57.500 57.500 57.500 56.000 53.000 53.000 52.000 50.000 47.500 47.500 40.000 35.000 32.250 30.000 20.000 10.000 1.000 0.033 0.159 1.310 0.071 0.408 0.152 0.326 0.375 0.074 1.367 0.146 0.319 0.333 0.115 0.176 0.623 0.677 0.656 0.033 0.192 1.502 1.573 1.981 2.133 2.459 2.835 2.909 4.276 4.422 4.741 5.074 5.189 5.365 5.988 6.665 7.321 0.037 0.077 1.232 0.594 0.716 0.920 0.641 0.665 0.079 1.227 2.240 0.327 0.207 0.082 0.125 0.443 0.481 0.465 0.037 0.115 1.347 1.941 2.657 3.577 4.218 4.884 4.963 6.189 8.430 8.756 8.964 9.046 9.171 9.614 10.095 10.560 0.000 7.321 10.560 END LOAD CASE 1 AXIAL AND SHEAR FORCE ) C Page 6 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No Description Design Owner Status • 29299 -682 Design No: Summit Job #5558 Engineer : RKT : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA • 90 mph /78 mph + 1/2" Radial Ice • U. S. West Client: Summit Manufacturing, LLC • Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- MOMENTS and DEFLECTIONS: LOAD CASE 1: BASIC WIND VELOCITY = 90.00 mph Segmnt From Elev Ant/ (ft) Arm MOMENTS (ft -kips) From From Shaft P -Delta Wind Effects ] [ -- DEFLECTIONS (inch) ] No Total W/ Total Total P -Delta P -Delta Rotation Moment Effects Effects (deg) 60.00 0.031 57.50 0.084 57.50 0.084 57.50 0.084 56.00 2.826 53.00 10.228 53.00 10.228 52.00 14.140 50.00 23.216 47.50 34.561 47.50 34.561 40.00 93.997 35.00 133.621 32.25 155.414 30.00 173.244 20.00 252.492 10.00 331.739 0.00 410.987 0.000 0.159 0.159 0.159 0.367 1.052 1.052 1.358 2.088 3.220 3.220 8.144 12.718 15.670 18.318 32.746 51.773 75.779 0.000 0.003 0.003 0.039 0.191 0.382 0.484 0.600 0.869 1.074 1.173 2.780 3.724 4.090 4.617 6.153 7.202 7.590 0.031 0.246 0.246 0.282 3.384 11.662 11.763 16.098 26.174 38.856 38.954 104.922 150.062 175.174 196.179 291.391 390.715 494.356 21.011 20.168 20.168 19.887 18.765 17.643 17.085 16.528 15.421 14.598 14.328 10.184 7.885 7.042 5.861 2.644 0.666 0.000 ( END LOAD CASE 1 MOMENTS AND DEFLECTIONS ) 21.448 2.740 20.587 2.740 20.587 2.740 20.300 2.740 19.152 2.737 18.005 2.721 17.435 2.721 16.865 2.712 15.734 2.685 14.892 2.637 14.616 2.637 10.382 2.369 8.035 2.102 7.174 1.963 5.970 1.846 2.691 1.272 0.677 0.645 0.000 0.000 Page 7 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- ACTUAL VS. ALLOWABLE STRESSES: LOAD CASE Note: Per 1: BASIC WIND VELOCITY = 90.00 mph TIA /EIA Sec. 3.1.1.1: Allow a 1/3 stress increase for poles under 700 feet in height. The allowable stresses shown include the factor of 1.333 ( ACTUAL STRESSES Segmnt Bending Axial Torsion Shear Elev (fb] (fa] (ft] (fv] (ft) (ksi) (ksi) (ksi) (ksi) - - -] Combined (Ftot] (ksi) Allow. Stress (Flo] (ksi) Actual/ Allowable (Ftot /Fb] Ratio 60.00 0.010 0.003 0.000 0.008 57.50 0.071 0.019 0.002 0.023 57.50 0.071 0.150 0.349 0.269 57.50 0.082 0.157 0.406 0.387 56.00 0.947 0.195 0.455 0.521 53.00 3.045 0.202 0.504 0.677 53.00 3.071 0.233 0.657 0.798 52.00 4.109 0.266 0.701 0.914 50.00 6.390 0.267 0.671 0.909 47.50 8.987 0.382 0.898 1.103 47.50 9.009 0.395 1.096 1.502 40.00 20.799 0.392 0.940 1.445 35.00 27.009 0.400 0.854 1.410 32.25 23.464 0.305 0.634 1.062 30.00 25.201 0.309 0.608 1.054 20.00 31.392 0.316 0.510 1.012 10.00 35.808 0.325 0.434 0.981 0.00 39.010 0.331 0.374 0.952 ( END LOAD 0.019 0.100 1.093 1.395 2.039 3.838 4.156 5.193 7.198 9.989 10.425 21.590 27.688 23.949 25.672 31.818 36.215 39.408 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 CASE 1 ACTUAL VS. ALLOWABLE STRESSES ) 0.0004 0.0019 0.0210 0.0268 0.0392 0.0738 0.0799 0.0999 0.1384 0.1921 0.2005 0.4152 0.5325 0.4606 0.4937 0.6119 0.6964 0.7578 Page 8 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner • U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : ANTENNA AND ARM PROPERTIES AND LOAD DATA: LOAD CASE 2: WIND VELOCITY = 77.94 mph + 0.50 inches Radial Ice. Arm Load Antenna Antenna Ant Mount. Applic. Arm Ice Area Force Antenna Arm Elev. Elev. Length Load [CaAa] [gzGhCaAa] Weight No. (ft) (ft) (ft) Case (a£) (lbs) (lbs) [1] 57.500 61.500 0.0000 W/ Ice: 1.50 47.10 144.00 Description: 5/8" Lightning Rod [ Gh ] [ Kz ] 1.69 1.195 W/ Ice: [ qz ] (psf) 18.579 [qz] [Gh] (psf) 31.399 [2] 57.500 57.500 2.0000 W/ Ice: 33.00 1016.45 1441.00 Description: (3) 12 -Ft "T" Arms [ qz ] [ Gh ] [ Kz ] (paf) 1.69 1.172 W/ Ice: 18.226 [qz] [Gh] (psf) 30.802 [3] 57.500 57.500 0.0000 W/ Ice: 15.42 Description: (2) EMS RR33- 20 -XX_P [ Gh ] [ Kz ] 1.69 1.172 W/ Ice: 474.96 141.54 [ qz ] [qz] [Gh] (psf) (psf) 18.226 30.802 [4] 56.000 56.000 0.0000 W/ Ice: 17.16 Description: (3) US West Remote Unit [ Gh ] ( Kz 1.69 1.163 W/ Ice: [ qz ] (psf) 18.089 524.58 445.50 [qz] [Gh] (paf) 30.570 [5] 53.000 53.000 0.0000 W/ Ice: 23.13 Description: (3) EMS RR33 -20 -XX P [ qz ] [ Gh ] [ Kz ] (psf) 1.69 1.145 W/ Ice: 17.806 696.05 212.31 [qz] [Gh] (psf) 30.093 [6] 53.000 53.000 2.0000 W/ Ice: 17.00 Description: Tri -Arm Support Assembly [ Gh ] [ Kz ] 1.69 1.145 W/ Ice: [ qz ] (psf) 17.806 511.58 319.00 [qz] [Gh] (psf) 30.093 [7] 52.000 52.000 0.0000 W/ Ice: 17.16 Description: (3) US West Remote Unit [ Gh ] [ Kz ] 1.69 1.139 W/ Ice: [ qz ] (paf) 17.710 513.59 445.50 [qz] [Gh] (psf) 29.929 [8] 47.500 47.500 2.0000 W/ Ice: 33.00 Description: (3) 12 -Ft "T" Arms 962.46 1441.00 ( qz ] [qz] [Gh] C Gh ] [ Kz ] (psf) (psf) 1.69 1.110 W/ Ice; 17.258 29.165 [9] 47.500 47.500 0.0000 W/ Ice: 61.43 1791.63 546.00 Description: (8) Allgon 7131.20 Sector r ... 1 L.. L7n ...J_._...1_.Xz.J... 1.69 1.110 W/ Ice: 17.258 29.165 ( ( Page 9 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner • U. S. West Client: Summit Manufacturing, LLC Status Engineering Final Design Revision: Rev. Date : POLE SHAFT LOADS: LOAD CASE 2: WIND VELOCITY = 77.94 mph with 0.50 inches Radial Ice. Design Loads per TIA /EIA -222 -F Standard; Gust Factor Gh = 1.69 Pole DL Overload Factor = 1 Per TIA /EIA Table 1: Note 3: For all cross sectional shapes, Force Coefficient (Cf] need not exceed 1.2 for any value of C. (Where C =sgrt(Kz) *V *D.) Top of Veloc Pole Projected Area Segment Shaft Segment Expos Press Veloc Force Shaft Segment Wind Segment Elev. Coeff (qz] Coeff Coeff (Ae] [Cf Ae] Force Weight (ft) (Kz] (paf) [C] (Cf] (sf) (sf) (lbs) (lbs) 60.000 1.186 18.45 116.73 0.650 1.467 0.953 29.72 43.79 57.500 1.172 18.23 119.54 0.650 2.231 1.450 44.93 66.67 57.500 1.172 18.23 119.54 0.650 0.000 0.000 0.00 0.00 57.500 1.172 18.23 119.54 0.650 0.752 0.489 15.06 22.49 56.000 1.163 18.09 121.19 0.650 3.050 1.983 60.76 91.28 53.000 1.145 17.81 124.41 0.650 3.117 2.026 61.45 93.39 53.000 1.145 17.81 124.41 0.650 1.583 1.029 30.97 47.49 52.000 1.139 17.71 125.46 0.650 1.600 1.040 31.13 48.02 50.000 1.126 17.51 127.52 0.650 3.250 2.113 62.70 97.62 47.500 1.110 17.26 130.01 0.650 2.481 1.613 47.37 74.60 47.500 1.110 17.26 130.01 0.650 0.835 0.543 15.84 25.13 40.000 1.057 16.43 136.87 0.650 13.934 9.057 257.44 420.09 35.000 1.017 15.82 140.84 0.650 9.235 6.003 162.97 437.28 32.250 1.000 15.55 140.80 0.650 3.755 2.440 64.42 142.09 30.000 1.000 15.55 143.72 0.650 5.757 3.742 98.35 218.11 20.000 1.000 15.55 156.72 0.650 20.273 13.178 346.35 770.16 10.000 1.000 15.55 169.71 0.650 21.941 14.261 374.83 836.53 1.000 1.000 15.55 181.41 0.650 21.172 13.762 361.70 809.63 Summation TOTAL = 2065.99 4244.37 ( END LOAD CASE 2 -- POLE SHAFT LOADS ) Page 10 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner U. S. West Client: Summit Manufacturing, LLC Status Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- AXIAL AND SHEAR FORCES: LOAD CASE 2: WIND VELOCITY = 77.94 mph with 0.50 inches Radial Ice. Tube Segment Segment Elevation No. (ft) Axial Load (kips) Cumulative Axial Load (kips) Horiz. Shear (kips) Cumulative Horiz. Shear (kips) 1. 60.000 2. 57.500 3. 57.500 4. 57.500 5. 56.000 6. 53.000 7. 53.000 8. 52.000 9. 50.000 10. 47.500 11. 47.500 12. 40.000 13. 35.000 14. 32.250 15. 30.000 16. 20.000 17. 10.000 18. 1.000 Base 0.000 0.044 0.211 1.441 0.164 0.537 0.306 0.366 0.494 0.098 1.516 0.571 0.420 0.437 0.142 0.218 0.770 0.837 0.810 0.044 0.254 1.695 1.859 2.396 2.702 3.068 3.562 3.660 5.175 5.746 6.166 6.604 6.746 6.964 7.734 8.571 9.380 0.030 0.092 1.016 0.490 0.585 0.757 0.543 0.545 0.063 1.010 1.807 0.257 0.163 0.064 0.098 0.346 0.375 0.362 0.030 0.122 1.138 1.628 2.214 2.971 3.514 4.058 4.121 5.131 •6.938 7.196 7.359 7.423 7.521 7.868 8.243 8.604 9.380 8.604 ( END LOAD CASE 2 -- AXIAL AND SHEAR FORCE ) Page 11 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Owner • Status • 29299 -682 Design No: Summit Job #5558 Engineer : RKT 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA 90 mph /78 mph + 1/2" Radial Ice U. S. West Client: Summit Manufacturing, LLC Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- MOMENTS and DEFLECTIONS: LOAD CASE 2: WIND VELOCITY = 77.94 mph with 0.50 inches Radial Ice. [ Segmnt From Elev Ant/ (ft) Arm MOMENTS (ft -kips) From From Shaft P -Delta Wind Effects ] [ -- DEFLECTIONS (inch) 3 No Total W/ Total Total P -Delta P -Delta Rotation Moment Effects Effects (deg) 60.00 0.071 57.50 0.188 57.50 0.188 57.50 0.188 56.00 2.496 53.00 8.685 53.00 8.685 52.00 11.956 50.00 19.525 47.50 28.986 47.50 28.986 40.00 78.023 35.00 110.715 32.25 128.696 30.00 143.407 20.00 208.791 10.00 274.175 0.00 339.559 0.000 0.127 0.127 0.127 0.292 0.835 0.835 1.078 1.657 2.554 2.554 6.451 10.064 12.394 14.483 25.849 40.806 59.641 0.000 0.003 0.003 0.037 0.186 0.378 0.484 0.605 0.885 1.099 1.198 2.928 3.943 4.337 4.903 6.547 7.663 8.074 0.071 0.319 0.319 0.352 2.974 9.899 10.005 13.639 22.067 32.639 32.737 87.402 124.722 145.427 162.793 241.187 322.645 407.273 17.282 16.588 16.588 16.357 15.432 14.508 14.048 13.590 12.678 12.001 11.778 8.368 6.477 5.784 4.813 2.170 0.547 0.000 ( END LOAD CASE 2 -- MOMENTS AND DEFLECTIONS ) 17.746 2.272 17.032 2.271 17.032 2.271 16.794 2.271 15.842 2.270 14.892 2.256 14.419 2.256 13.947 2.248 13.010 2.225 12.313 2.185 12.084 2.185 8.578 1.961 6.637 1.739 5.925 1.623 4.929 1.526 2.220 1.050 0.558 0.532 0.000 0.000 Page 12 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Owner • Status • 29299 -682 Design No: Summit Job #5558 Engineer : RKT 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA 90 mph /78 mph + 1/2" Radial Ice U. S. West Client: Summit Manufacturing, LLC Engineering Final Design Revision: Rev. Date : POLE SHAFT SEGMENTS -- ACTUAL VS. ALLOWABLE STRESSES: LOAD CASE Note: Per Segmnt Elev (ft) 2: WIND VELOCITY = 77.94 mph with 0.50 inches Radial Ice. TIA /EIA Sec. 3.1.1.1: Allow a 1/3 stress increase for poles under 700 feet in height. The allowable stresses shown include the factor of 1.333 Bending [fb] (ksi) ACTUAL STRESSES Axial Torsion Shear (fa] [ft] [fv] (ksi) (ksi) (ksi) Combined [Ftot] (ksi) Allow. Actual/ Stress Allowable [Fb] [Ftot /Fb] (ksi) Ratio 60.00 0.022 0.005 0.000 0.006 57.50 0.092 0.025 0.005 0.024 57.50 0.092 0.169 0.291 0.227 57.50 0.102 0.186 0.338 0.325 56.00 0.832 0.235 0.378 0.434 53.00 2.584 0.256 0.419 0.562 53.00 2.612 0.291 0.549 0.665 52.00 3.481 0.334 0.584 0.760 50.00 5.388 0.336 0.559 0.754 47.50 7.549 0.462 0.746 0.914 47.50 7.572 0.513 0.906 1.236 40.00 17.326 0.510 0.777 1.188 35.00 22.448 0.521 0.706 1.158 32.25 19.479 0.397 0.524 0.871 30.00 20.912 0.401 0.502 0.864 20.00 25.984 0.408 0.422 0.829 10.00 29.569 0.417 0.359 0.801 0.00 32.138 0.424 0.309 0.776 0.028 0.128 0.935 1.184 1.765 3.310 3.584 4.469 6.159 8.512 8.896 18.158 23.194 20.022 21.444 26.481 30.054 32.617 ( END LOAD CASE 2 ACTUAL VS. ALLOWABLE STRESSES 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 52.00 ) 0.0005 0.0025 0.0180 0.0228 0.0339 0.0637 0.0689 0.0860 0.1184 0.1637 0.1711. 0.3492 0.4460 0.3850 0.4124 0.5092 0.5780 0.6272 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner • U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : M O N O P O L E B A S E P L A T E D E S I G N D E T A I L S Shaft Shape Base Dia, DF PT- to -PT, DP • Min Bolt Circle .: 18 Sided Polygon 28.130 Inches 28.564 Inches 35.130 Inches Stress Increase ...: 1.333 Factor Base Plate Shape ..: Square Use Bolt Circle ...: 34.000 Inches Base Reactions Moment Axial Load DESIGN 494.356 Ft -Kips 7.321 Kips USER 494.356 Ft -Kips 7.321 Kips Anchor Bolt Details Number of Bolts Bolt Diameter Bolt Type Y- Distance Mom. of Inertia Bolt Tension, T Allowable Tension Bolt Compression, C . DESIGN USER 4 2.250 Inches #18J ASTM A615 0 617.06 InA4 168.87 Kips 194.81 Kips 170.70 Kips 4 2.250 Inches #18J ASTM A615 0 578.00 InA4 174.48 Kips 194.81 Kips 176.31 Kips Base Plate Details Plate Moment, MPL Bend Plane, W Plate Thickness, t Plate Width Plate Steel Gross Weight Net Weight Allowable Stress Actual Stress Act. /Allow Ratio DESIGN 597.44 In -Kips 15.49 Inches 2.152 Inches 30.841 Inches ASTM A572 GRADE 50 (50 580.50 Lbs 433.10 Lbs 49.99 Ksi 49.99 Ksi 1.00 USER 517.47 In -Kips 18.54 Inches 2.250 Inches 33.000 Inches KSI) ASTM A572 GRADE 50 (50 KSI) 694.90 Lbs 540.80 Lbs 49.99 Ksi 33.08 Ksi 0.66 B A S E P L A T E R E S I G N S U M M A R Y USE FOLLOWING SPECIFICATIONS: Plate Thickness Plate Width /Diameter : Plate Weight 2.250 Inches 33.000 Inches (Square) 0.695 Kips Number of Bolts ..: 4 Bolt Circle • 34.00 Inches Bolt Diameter 2.25 Inches Bolt Type #18J ASTM A615 PJF_Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:55:40 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No 29299 -682 Design No: Summit Job #5558 Engineer : RKT Description : 60 -Ft Monopole - SEA270 Bow Lake Transfer Station: Tukwila, WA Design • 90 mph /78 mph + 1/2" Radial Ice Owner • U. S. West Client: Summit Manufacturing, LLC Status • Engineering Final Design Revision: Rev. Date : S U M M A R Y O F C U R R E N T C A I S S O N D E S I G N Diameter. (ft) Min. Depth (ft) Depth Used (ft) . Rebar Area (in''2) Rebar Used Water at (ft) 5.00 Compression (kips): .... 16.50 Horizontal (kips) ... 17.00 Uplift (kips) .: 16.00 Moment (Ft -kips) .: • (16) #9 Full Cohesion (ft) : 13.50 Rock at (ft) 8.00 Friction S.F 2.00 12.00 Lateral S.F 2.00 0.00 Concrete S.F 1.30 575.0 Concrete F'c (psi) : 3000.0 15.00 Steel Cover (in) ..: 4.00 0.00 SOIL PROFILE . Soil Layer Layer Thickness (ft) 1 5.00 2 8.50 3 16.50 Unit Weight (pcf) 110.00 110.00 47.60 Ult. Skin Allowable Friction Passive Cohesion Friction Bearing Angle- Phi Coeff.- KP (c) (psf) (psf) (deg) (psf) 0.00 0.00 0.00 1.000 0.00 520.00 0.00 32.00 3.255 0.00 1400.00 13600.00 32.00 3.255 0.00 LATERAL / MOMENT CAPACITY (CHECK) : Caisson Diameter (ft) Height Above Grade (ft) Depth Below Grade (ft) Concrete Volume (CY) Applied Moment From Loads (Working), Mwork(Ft -kip): Resisting Moment From Soil (Ult), Mult(Ft -kip) Moment S.F. (Mult / Mwork) Applied Horizontal Load (Working), Hwork (Kips) ..: Horizontal Soil Resistance (Ultimate), Hult (Kips): Horizontal S.F. (Hult / Hwork) Center of Rotation (from grade) (ft) Inflection Point (Max Design Moment Location (ft) Maximum Factored Design Moment for Reinf. (Ft -kip): Area Steel Required From Loads (inA2) ACI Minimum Steel (0.5 %) (in"2) Area Reinf. Steel Provided (in"2) Min Design 5.00 0.50 16.50 12.36 728.60 1505.84 2.07 12.00 28.02 2.34 12.30 6.00 1003.64 8.40 14.14 16.00 Actual Design 5.00 0.50 17.00 12.73 732.20 1665.78 2.28 12.00 28.11 2.34 12.60 6.00 1003.64 8.40 14.14 16.00 UPLIFT CAPACITY CHECK : Actual Uplift on Caisson (Kips) Allowable Uplift Capacity (Kips) 0.00 107.76 COMPRESSION CAPACITY CHECK : Actual Compression on Caisson (Kips) Total Compression (Includes Concrete Wt.) (Kips) Allowable Compression Capacity (Kips) 8.00 25.67 334.74 0.00 114.43 8.00 26.16 340.23 CAISSON DESIGN: USE: 5.00 ft Diameter X 17.50 ft Long (Concrete Volume = 12.73 CY) Reinf: (16) #9 Vert, w /Closed Ties: (12) #5 @6.0 ", remaining ties 12)18.0" (ASTM A615) Zipper Zeman Associates Inc. Geotechnical and Environmental Consulting Odelia Pacific Corporation 450 — 110`h Avenue N.E., Room 209 Bellevue, Washington 98004 Attention: Mr. Rich Shoji Subject: sa L J -477 15 September 1999 Subsurface Exploration and Geotechnical Engineering Evaluation Proposed US WEST Wireless SEA 270 Cell Site Tower 18700 Orillia Road South Tukwila, Washington Dear Mr. Shoji: • Zipper Zeman Associates, Inc. ( ZA) ' is pleased to submit this report providing the results of our Subswface Exploration and Geotechnical Engineering Evaluation conducted for the above referenced project. The purpose of this evaluation was to interpret general surface and subsurface site conditions, from which we could determine the feasibility of the project with respect to geotechnical concerns and formulate recommendations regarding site preparation, tower foundations, equipment building foundations, structural fill and other considerations. The scope of services completed for this study included a site surface reconnaissance, subsurface exploration, geotechnical engineering analyses, and preparation of this report. Sampling and testing for the presence of contamination was beyond the scope of this evaluation. This report has been prepared in accordance with generally accepted geotechnical engineering practices for the exclusive use of US WEST Wireless, Odelia Pacific, and their agents, for specific application to this project and site location. SITE AND PROJECT DESCRIPTION The site is located at 18700 Orillia Road in Tukwila, Washington. The proposed new monopole site is located within the King County Bow Lake solid waste transfer station property. The proposed monopole will be constructed along the western margin of the property, upslope of the transfer station's west exit driveway. The layout of the proposed project site and adjacent site features are shown on the attached Figure 1, the Site and Exploration Plan. We understand that the proposed project will include the construction of anew 45 -foot tall monopole and placement of a prefabricated ground cabinet equipment shel `on'' a o idieta slab. It does not appear that any significant grading or earthwork will be necessary to affect the installation due to the relatively level nature of the site. NOV 1 .) 1999 It should be emphasized that the conclusions and recommendatio> .1):,. 4iiiks report are based on our understanding of the currently currentlyritiNtel as derived from 1.4 ancvek. h2 t�y'06�...1999 Nf?IU �j g 1�1q� s i3 Proposed SEA 270 Tower 1 -477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 2 information provided to us by Odelia Pacific Corporation in a 1 July 1999 transmittal. If any changes are made in the project as compared to the project description contained herein, we should be allowed to review such changes and modify our report recommendations as needed. FIELD EXPLORATION We explored surface and subsurface conditions at the project site on 31 August 1999. Our surface evaluation consisted of a visual reconnaissance, and our subsurface exploration consisted of advancing one hollow -stem auger soil boring to a depth of approximately 30 feet below existing grades. This boring is designated as B -1 on Figure 1, the Site and Exploration Plan. The location and depth of our exploration was selected based upon site access, the proposed monopole location, and the geologic conditions. We determined the location of our exploration using a site plan provided to us by Odelia Pacific Corporation, Inc. and by measuring from existing site features with a hand held measuring tape. As such, the exploration location shown on Figure 1 should be considered accurate only to the degree implied by our measuring methods. The ground surface elevation at the boring location shown on Figure 1 was determined relative to topographic information provided on Sheet A -1, 22 April 1999, prepared by KDC Architects - Engineers, P.C. It should be emphasized that our exploration revealed subsurface conditions only at a discrete location on the project site and that actual conditions could vary at other locations. Furthermore, the nature and extent of any such variations will not become evident until construction activities have begun. If significant variations are observed at that time, we may need to modify our conclusions and recommendations to reflect actual conditions. Exploratory Methods Our soil boring was advanced with 41/4-inch I.D. continuous -flight hollow -stem auger, using a track- mounted drill rig operated by an independent firm working under subcontract to ZZA. An experienced engineering geologist from our firm continuously observed the boring, logged the subsurface conditions, obtained representative soil samples, and transported the samples to our laboratory for further classification and possible testing, as deemed necessary. Throughout the drilling operation, soil samples were obtained from our borings at 5 -foot depth intervals by means of the Standard Penetration Test procedure (ASTM: D- 1586). This test and sampling method consists of driving a standard 2 -inch (outside diameter) split - barrel sampler a distance of 18 inches into the soil with a 140 -pound hammer free - falling a distance of 30 inches. The number of blows required to drive the sampler through each of three 6 -inch penetration intervals is counted, and the total number of blows struck during the final 12 inches is considered the Standard Penetration Resistance, or "blow count ". If a total of 50 blows is struck within one 6 -inch interval, the driving is ceased and the blow count is recorded as 50 blows for the actual number of inches of penetration. The resulting Standard Penetration Resistance values (N- values) provide a measure of the relative density of granular soils and the relative consistency of cohesive soils. Proposed SEA 270 Tower J -477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 3 Samples recovered from the exploration location were visually classified in the field during the exploration program. Representative portions of the samples were carefully packaged in moisture tight containers and transported to our laboratory where the field classifications were verified or modified as required. Visual classification was generally done in accordance with the Unified Soil Classification system. Visual soil classification includes evaluation of color, relative moisture content, soil type based upon grain size, and accessory soil types included in the sample. Soil classifications are presented on the exploration log enclosed with this report. Moisture content determinations were performed on representative samples obtained from the exploration in order to aid in identification and correlation of soil types. The determinations were made in general accordance with the test procedures described in ASTM: D -2216. The results are shown on the exploration log enclosed with this report. A grain size analysis was performed on a sample in general accordance with ASTM: D -422. The results of the grain size analysis were used in the classification of soils, and are attached at the end of this report. The attached boring log describes the various types of soils encountered in the boring, based primarily on visual interpretations made in the field and supported by our subsequent laboratory testing of selected samples. Our log also indicates the approximate depth of the contacts between different soil types, although these contacts may be gradational or undulating. Where a change in soil type occurred between sampling intervals, we inferred the depth of contact. In addition, our log indicates the Standard Penetration Resistance at each sample location, and any laboratory tests performed on the soil samples. Depth to groundwater is also indicated on the boring log, where applicable. Groundwater depth is typically estimated from the moisture content of soil samples, the wetted height of the drilling rods, and/or the groundwater level measured in the boring after the auger has been extracted. SITE CONDITIONS The following sections describe our observations, measurements, and interpretations regarding surface, soil, groundwater and seismic conditions at the project site. An interpretive log of our exploration is attached at the end of this report. Surface Conditions The site comprises an existing solid waste transfer station owned and operated by King County. The overall facility slopes downward from the southwest to the northeast. The proposed monopole location is along the far western property boundary, on a relatively level area above the site's western exit driveway. The area is mantled with grass and blackberry bushes. Neither standing nor flowing water were observed on site during our field exploration. The site is bordered by a chain link fence to the west, a grassy slope extending down to the east, a brush - covered area to the north, and a fence to the south. Proposed SEA 270 Tower J-477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 4 Utility Locate Service markings on site indicate the potential presence of underground power and telephone cables in close proximity to the monopole location. An underground utility vault and wooden pole also occupied the site. The proposed facility location and pertinent surface features are shown on Figure 1. Subsurface Conditions According to information presented in the Preliminary Geologic Map of Seattle and Vicinity, Washington (U.S.G.S. Map I -354, 1962), the project site is underlain by "Younger Gravel ", a recessional outwash -type granular soil deposited during the Vashon Stade of the Fraser Glaciation. The outwash is described as chiefly sand and fine gravel, and commonly overlies the Vashon lodgement glacial till. The outwash soils are normally consolidated and may be on the order of 100 feet deep. Boring 13-1 disclosed soils consistent with the published map data. Boring B -1 was drilled at the project site on 31 August 1999. The location of this boring is shown on Figure 1, relative to existing site features. The boring was advanced approximately 14 feet south of the proposed monopole location due to conflicts with underground utilities. The subsurface soil profile as observed in our boring included approximately 5 feet of loose to medium dense, damp, brown, silty sand fill material. The fill contained some gravel, scattered cobbles, and pieces of black plastic. The fill was underlain by medium dense to dense, moist to saturated (below approximately 14 feet), brown, gravelly sand and silty sand. These soils extended to the boring's 30 -foot termination depth. Groundwater Conditions At the time of our evaluation, groundwater was observed in our boring at a depth of approximately 13.5 feet below grade. Groundwater conditions should be expected to fluctuate due to changes in season, precipitation patterns, site utilization, on -site or off -site irrigation activities, and other on- and off -site factors. It should be noted that a perched groundwater condition could develop when a soil of relatively low permeability impedes the downward and lateral migration of groundwater. A perched condition can also develop at a fill /native soil interface. Seismic Conditions According the Seismic Zone Map of the United States contained in the 1997 Uniform Building Code, the project site lies within Seismic Risk Zone 3. The medium dense to dense sands encountered to the boring's termination depth of 30 feet meet the soil profile type SD as defined by Table 16 -J of the 1997 Uniform Building Code. This designation reflects a stiff soil profile characterized by Standard Penetration Test (SPT) values in the range of 15 to 50, a shear wave velocity in the range of 600 to 1,200 feet per second, and an undrained shear strength ranging from 1,000 to 2,000 pounds per square foot. Proposed SEA 270 Tower J -477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 5 CONCLUSIONS AND RECOMMENDATIONS Current development plans call for construction of a 45 -foot tall communications monopole and placement of an equipment ground cabinet placed on a concrete slab. The proposed construction is considered feasible from a geotechnical perspective, given the conditions disclosed in our field exploration. Our specific recommendations concerning site preparation, the equipment shelter foundation, and tower foundation are presented in the following sections. Site Preparation Site preparation will likely involve only minor stripping and grubbing, possibly some minor grading, and preparation of subgrades. The following comments and recommendations apply to site preparation. Clearing and Grubbing Site preparation should include stripping, grubbing, and removal of all surficial vegetation, topsoil, root masses, and deleterious debris from the tower and ground shelter foundation and fill areas. We recommend that the stripped materials be wasted off site or used for landscaping purposes. We anticipate that stripping depths of about 3 inches will be necessary across the site, although areas of deeper organic -rich surficial deposits, or deleterious debris, may be encountered. If filling is required for preparation of the site, fill material should be placed and compacted according to the recommendations presented in the Structural Fill section of this report. Wet Conditions The near- surface site soils consist primarily of silty sand, and are considered to be moderately sensitive to moisture due to their relatively high sand content. However, the contractor should exercise care when working during wet weather, as site soils could become disturbed in the presence of excess moisture. A working surface of quarry spalls crushed concrete, or clean pit -run may become necessary if work is performed during wet weather. Frozen Subgrades If earthwork takes place during freezing conditions, we recommend that all exposed subgrades be allowed to thaw and be recompacted prior to placing subsequent lifts of structural fill, or foundation components. Structural Fill It appears that minor filling may be required to produce a flat compound. The following comments, recommendations, and conclusions regarding the use of structural fill are provided for 1 design and construction purposes. Proposed SEA 270 Tower J -477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 6 Materials Structural fill includes any fill materials placed under foundations, concrete slabs, pavements, driveways, and other permanent structures. Typical materials used for structural fill include clean, well - graded sand and gravel (pit -run), clean sand, crushed rock, crushed recycled concrete, and various soil mixtures of silt, sand, and gravel. In our opinion, on -site granular soils are suitable for structural fill applications, provided the moisture content of the soil is within a few percent of optimum at the time of compaction. Soils used for structural fill should not contain individual particles greater than about 6 inches in diameter and should be free of organics, debris, and other deleterious materials. Given these prerequisites, the suitability of soils used for structural fill depends primarily on the grain - size distribution and moisture content of the soils when they are placed. As the "fines" content (passing the U.S. No. 200 Sieve) increase, soils become more sensitive to small changes in moisture content. Soils containing more than about 5 percent fines by weight cannot be consistently compacted to a firm, unyielding condition when the moisture content is more than about 2 percentage points above optimum. The use of "clean" soil, or "select" fill is necessary for fill placement during wet - weather site work. Clean soils are defined as granular soils that have a fines content of less than 5 percent (by weight), based on the soil fraction passing the U.S. No. 4 Sieve, with at least 40 percent retained above the No. 4 Sieve. The existing, near - surface silty sand fill material encountered at the site appears to be suitable for reuse as structural fill provided the moisture content of these soils can be maintained with ±2 percent of the optimum moisture content as determined by ASTM test method D -1557. Structural fill materials should be placed in horizontal lifts not exceeding 8 inches of loose thickness, and each lift should be thoroughly compacted with a mechanical compactor. Using the modified Proctor maximum dry density (ASTM:D -1557) as a standard, we recommend that structural fill used for various on -site applications be compacted to the , following minimum densities: () ,Y i Fill Application Foundation or slab subgrade Gravel drive /parking subgrade (if required) Minimum Compaction 90 percent 90 percent Regardless of location or material type, all structural fill should be placed over firm, unyielding subgrades. We recommend that a ZZA representative be allowed to observe all subgrades before placement begins, and to perform a series of in -place density tests during structural fill placement. In this way, the adequacy of soil compaction efforts may be evaluated as earthwork progresses, to minimize construction delays, Tower Foundation Recommendations - General Soils disclosed by boring B -1 included approximately 5 feet of surficial fill material over medium dense to dense sand, Support for the proposed 45 -foot monopole within the soils Proposed SEA 270 Tower J-477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 7 disclosed by boring B -1 is feasible from the geotechnical perspective, in our opinion. Presented below are our recommendations for a drilled pier foundation. Recommendations for other foundation types could be made available at the request of US West or Odelia Pacific Corporation. Drilled Pier Foundation Recommendations A drilled pier foundation deriving support from the medium dense to dense sand soils is feasible from the geotechnical perspective. The following recommendations and comments are provided for purposes of drilled pier foundation design and construction. Compressive Capacities We recommend that the drilled pier penetrate at least 5 feet below the ground surface. For vertical compressive soil bearing values, we recommend using the unit end bearing capacities presented in Table 1 below. The embedment depth refers to the depth of penetration below the ground surface. We assume that adequate pier embedment for end - bearing capacity, uplift, and horizontal resistance can generally be obtained within the limits of the soils disclosed by boring B -1. The allowable end bearing capacities, presented in Table 1, include a safety factor of 2.0 or more. Frictional Capacities For frictional resistance along the shafts of drilled piers, acting both downward and in uplift, we recommend using the allowable skin friction values listed in Table 2. We recommend that frictional resistance be neglected in the uppermost 5 feet below the ground surface. The allowable skin friction values presented include a safety factor of at least 2.0. Table 1 Allowable End Bearing Capacities Depth (feet) Allowable Bearing Capacity (tsf) Limiting Point Resistance (tsf) Allowable Skin Friction Capacities 5 — 25 2 D/B 10 Allowable Skin Friction (tsf) 25 -30 4D /B 18 Notes: D = embedment depth (in feet) into dense soils greater than 5 feet below existing grades. B = pier diameter (feet) Frictional Capacities For frictional resistance along the shafts of drilled piers, acting both downward and in uplift, we recommend using the allowable skin friction values listed in Table 2. We recommend that frictional resistance be neglected in the uppermost 5 feet below the ground surface. The allowable skin friction values presented include a safety factor of at least 2.0. Table 2 Allowable Skin Friction Capacities Depth (feet) Allowable Skin Friction (tsf) 5 — 25 0.13 25 -30 0.35 Proposed SEA 270 Tower J -477 18700 Orillia Road 15 September 1999 Tukwila, Washington Page 8 Lateral Capacities For design against lateral forces on the drilled piers, two methods are typically used. The parameter used to select the appropriate design method is the length to pier stiffness factor ratio L /T, where L is the pier length in inches, and T is the relative stiffness factor. The relative stiffness factor (T) should be computed by: T = (EI /nh)112 Where: E = modulus of elasticity (psi) I = moment of inertia (in4) nh = constant of horizontal subgrade reaction (pci) The factors E and I are governed by the internal material strength characteristics of the pier. Representative values of nh for the soil observed this site are presented subsequently. Piers with a L/T ratio of less than 2 may be assumed to be relatively rigid and acting as a pole. The passive pressure approach may be used for this condition. For piers with a L/T ratio greater than 2, the modulus of subgrade reaction method is typically used. Both of these methods are discussed below. Passive Pressure Method The passive pressure approach is conservative by neglecting the redistribution of vertical stress and shear forces that develop near the bottom of the pier and contribute to resisting lateral loads. We recommend using the allowable passive earth pressures (expressed as equivalent fluid unit weights) listed in Table 3 below. The allowable passive earth pressures presented in Table 3 may be assumed to be acting over an area measuring 2 pier diameters in width by a maximum of 8 pier diameters in depth, neglecting the uppermost 2 feet of embedment below the ground surface. According to the NAVFAC Design Manual 7.2, a lateral deflection equal to about 0.002 times the pier length would be required to mobilize the full allowable passive pressure presented above. Higher deflections would mobilize higher passive pressures. When developing the passive pressures listed in Table, we have assumed a safety factor of at least 1.5, which is commonly applied to transient or seismic loading conditions. Table 3 Allowable Passive Earth Pressures Depth (feet) Allowable Passive Earth Pressure (pct) 2 -5 100 5-13 250 13 -30 • 125 The allowable passive earth pressures presented in Table 3 may be assumed to be acting over an area measuring 2 pier diameters in width by a maximum of 8 pier diameters in depth, neglecting the uppermost 2 feet of embedment below the ground surface. According to the NAVFAC Design Manual 7.2, a lateral deflection equal to about 0.002 times the pier length would be required to mobilize the full allowable passive pressure presented above. Higher deflections would mobilize higher passive pressures. When developing the passive pressures listed in Table, we have assumed a safety factor of at least 1.5, which is commonly applied to transient or seismic loading conditions. -�r 3 Proposed SEA 270 Tower 18700 Orillia Road Tukwila, Washington Modulus of Subgrade Reaction Method J-477 15 September 1999 Page 9 Using this method, the pier is designed to resist lateral loads based on acceptable lateral deflection limits. For sandy soils, the coefficient of horizontal subgrade reaction (Kh) is considered directly proportional to the depth along the pier. The expression for Kh is Kh = nhx, where x is the depth below the ground surface in inches. We recommend using values for the constant or horizontal subgrade reaction (nh) for the various soil layers presented in Table 4 below. Table 4 Constant of Horizontal Subgrade Reaction (nh) Depth (feet) nh (pci) 2 -5 5 -13 13 -30 20 70 60 Presented below is a summary of additional soil characteristics that may benefit the project structural engineer when developing p -y curves for drilled pier foundations. Table 5 Additional Soil Characteristics 0 (phi) 5 - 30 feet: 32 dejrees K (modulus) 2 — 5 feet: 20 lbs /in3 5 — 13 feet: 701bs /in3 13 — 30 feet: 601bs /in3 Unit weight 0 — 13 feet: 110 lbs /ft3 14 — 30 feet: 47 lbs /ft3 Construction Considerations Given the soil conditions encountered, we anticipate that it would likely be difficult to drill the foundation pier below the water table without casing. We recommend that the contractor be prepared to utilize casing in the event that pier sidewall sloughing occurs. The drilling contractor should be prepared to clean out the bottom of the boring if loose soil is observed or suspected. We recommend that the drilling contractor have a cleanout bucket on site to remove loose soils and/or mud from the bottom of the boring. The contractor should also be prepared to deal with the presence of cobbles, boulders, or other obstructions over the drilled depth interval. We recommend that the foundation concrete be tremied from the bottom of the hole to displace accumulated water and reduce the risk of contaminating or segregating the concrete mix. The Drilled Shaft Manual published by the Federal Highway Administration recommends that concrete be placed by tremie methods if more than 3 inches of water has accumulated in the excavation. •r� ''A 3 1 j Proposed SEA 270 Tower 18700 Orillia Road Tukwila, Washington Equipment Cabinet Foundation Slab Considerations J-477 15 September 1999 Page 10 We understand that a small ground equipment cabinet supported by a small pre -cast or cast -in -place concrete slab will supplement the tower. As such, the anticipated soil bearing pressure would be relatively low. The existing surficial fill soils disclosed by boring B -1 would be adequate for support of the concrete slab, in our opinion. If frost penetration is a consideration, a foundation embedment depth of 18 inches is typical for the project area. We recommend that the ground shelter slab be supported on a minimum 4 -inch thickness of crushed rock surfacing (3/4 -inch to 1.5 -inch aggregate size) placed above a non - organic, undisturbed subgrade. All slab subgrades should be proofrolled under the observation of a ZZA representative to verify that the subgrade is firm and non - yielding. The subgrade should be compacted to at least 90 percent of the modified Proctor maximum dry density (ASTM: D -1557) to a depth of at least 12 inches below the slab subgrade. Provided that the slab subgrade soils are prepared as recommended, and the soil moisture conditions are controlled or accounted for in the preparation of firm and non - yielding bearing surfaces, it is our opinion that the slab will experience less than 1 inch and 0.75 inches of total and differential settlement, respectively. CLOSURE The conclusions and recommendations presented in this report are based, in part, on the exploration that we performed for this study. If variations in subsurface conditions are discovered during earthwork, we may need to modify this report. Because the future performance and integrity of the tower foundation will depend largely on proper initial site preparation and construction procedures, monitoring by experienced geotechnical personnel should be considered an integral part of the construction process. We are available to provide geotechnical engineering services during the earthwork and foundation construction phases of the project, if so requested. If variations in the subgrade conditions are observed at that time, we would be able to provide additional geotechnical recommendations, thus minimizing delays as the project develops. We are also available to review preliminary plans and specifications before construction begins. 3 Proposed SEA 270 Tower 18700 Orillia Road Tukwila, Washington J-477 15 September 1999 Page 11 We appreciate the opportunity to be of service on this project. Should you have any questions regarding this report or any aspects of the project, please do not hesitate to call. Respectfully submitted, Zipper Zeman Associates, Inc. David C. Williams Associate Thomas A. Jones, P. E. Associate Enclosures: Figure 1, Site and Exploration Plan Boring Log B -1 Grain -size Distribution Plot lupines 4 i 7 l0l .<J ' PROPOSED 45 TO 55 -FOOT TALL MONOPOLE 3 /—EQUIPMENDT // / RACK / \ j u) N / 0 GRASS ASPHALT Legend B-1 BORING NUMBER AND S APPROXIMATE LOCATION ASPHALT N J 0 USWEST - SEA270A Cell Site Tukwila, Washington 40 80 SCALE IN FEET SOURCE: Site Plan prepored from a drawing provided by USWEST,. J-477 September, 1999 PROJECT: US West SEA 270 Cell Site JOB NO. J-477 BORING B -1 PAGE 1 OF 2 Location: 18700 Orillia Road South, Tukwila, WA Approximate Elevation: 278 feet [ Depth (ft) Soil Description n. a E H Standard y Sample Number Ground Water A 0 10 Penetration Resistance Blows per foot 20 30 40 Q Other 50 N = y z c y 1- Loose to medium dense, damp, brown, silty SAND with some gravel, scattered cobbles, and pieces of black plastic (Fill) S -1 S -2 S -3 S4 S-5 . . • . 4 • Ai • 4 • . • 6 27 30 20 25 GSA 5 Medium dense, moist, brown, gravelly SAND with some silt Medium dense to dense, wet to saturated (below 13.5 feet), brown, silty SAND with trace gravel ..._ 10 — ..� -- — ATD ..� 15 = 20 _ ».. — 25 Explanation I2 -inch O.D. split spoon sample it3 -inch I.D Shelby tube sample ® No Recovery V Groundwater level at time of drilling Monitoring Well Key Clean Sand g3 Cuttings 229 Bentonite r Grout B Screened Casing o 10 Plastic Limit 20 30 40 Moisture Content Natural 50 Liquid Limit I • ATD or date of measurement I Zipper Zeman Associates, Inc. 1 BORING LOG -'i PROJECT: US West SEA 270 Cell Site JOB NO. J-477 BORING B -1 PAGE 2 OF 2 Location: 18700 Orillia road South, Tukwila, Washington Approximate Elevation: 278 feet Depth (ft) I Soil Description a, E > co I- rn Sample Number Ground Water Standard 0 10 Penetration Resistance Blows per foot 20 30 40 Other 50 co > z Testing Dense, wet to saturated, brown, silty SAND with trace gravel S-6 • • • • • • 42 30 Total depth = 30 feet Completed 31 August 1999 7 35 40 45 50 E3 ® V Explanation 2 -inch O.D. split spoon sample -inch I.D Shelby tube sample No Recovery Groundwater level at time of drilling Monitoring Well Key • Clean Sand 2a Cuttings MI Bentonite MI Grout 8 Screened Casing o 10 Plastic Limit 20 30 40 Moisture Content Natural 50 Liquid Limit I • ATD or date of measurement I Zipper Zeman Associates, Inc. 1 BORING LOG n1 1 10 9 3 2 1 GRAIN SIZE DISTRIBUTION ASTM D422 1 SIZE OF 36' OPENING 12' IN 6' INCHES 3' 1 1/2' 3/4' 3/8' Silt U.S. 4 STANDARD 10 20 40 SIEVE 60 SIZE 100 200 HYDROMETER I I 1 I 1-- 1 1- - 1 L- 1 _ 1 I' 1000.00 100.00 10.00 1.00 0.10 GRAIN SIZE IN MILLIMETERS 0.01 0.00 BOULDERS COBBLES Coarse Fine Coarse Medium Fine Silt Clay GRAVEL SAND FINE GRAINED Exploration Sample 1 Depth (feet) Moisture ( %) Fines ( %) Description B -1 S -3 10 -11,5 23 21.2 silty SAND w /trace gravel ZIPPER ZEMAN ASSOCIATES, INC rn11►un*1 wu11 1-..,. ,,a. u.... ,...1 PROJECT NO: J.477 DATE OF TESTING: 9/1/99 PROJECT NAME: SEA 270 Coll Site 03/10/2000 12:38 OAGRA INGINUi IMG GLOBAL SOLUTIONS 4258203909 March 7, 2000 0-91M-13328-N c U S WEST Wireless 450 —110`" Avenue NE, Room 209 Bellevue, Washington 98004 Attention: Subject: Mr. Jack Dittmar KEN SARI Final Summary of Special Inspections U S WEST — SEA 270A 18700 Orillia Road Tukwila, Washington Building Permit No. MI99 -0203 �f PAGE 02 AGRA Garth & EnvksnosntaI. Inc. 11330 Na 122nd Way &As 100 KMlMnd, Washington USA •0344118 7M (425) i20.4101 fox (425) 021 -3e14 Dear Mr, Dittmar: AGRA Earth & Environmental, Inc. (AGRA) respectfully submits this final summary of special Inspection services for the referenced project. Our services were performed as requested and scheduled by Wren Construction, Daily Field Reports of our inspection were prepared at the time our services were provided. Our Daly Field Reports, which are attached, form the basis for this final summary letter. AGRA performed special inspection services for reinforced concrete for the drilled pier. We observed that the reinforcing steel, anchor bolts, and placement of concrete conformed with the approved plans and specifications. All concrete samples collected during construction met or exceeded the specified 28 -day compressive strength requirements. AGRA performed inspection of the bolting for the tower base anchor bolts. The bolts were In . accordance with the approved plans for the size, quantity, and tightness. $:IWONOPPOCWG PrgKliPSu1N117000011211 U S VMS Wi ss SEA 2TOA. vd 03/10/2000 12:38 1 U S West Wireless March 7, 2000 4259203909 PAGE 03 0.91M- 133213-N Page 2 In our opinion, the work which was inspected and referenced above was performed in general conformance with the approved plans. If you have questions or require additional information, please call at your convenience. Sincerely, K want (Ken) S. Sahi, P.E. Associate KSS /jdp Attachments: Daily Field Report Nos. 1 — 2 Compression Test Results (1) EXVIRE9 1? it / CC; Wren Construction Attn: Dan Nagy Fax No.: 425 - 339.2055 3,1WOROPROV00 ONC1113.Md111 7 0 0 0111 7yz0 U 3 WEST Vomieu\$EA ?70A.wp0 '; tNiiN11R1Ai ilii410{VVONf_ January 7, 2000 Ciz of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Catherine Tolosa 450 — 110th Avenue Ne, #209 Bellevue, WA 98004 RE: CORRECTION LETTER #1 Development Permit Application Number MI99 -0203 US West Wireless 18700 Orillia Road S Dear Ms. Tolosa: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Division. At this time, the Building Division, Fire Department, and Public Works Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your revision does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206)431 -3672. Sincerely, Am- Brenda Holt Permit Coordinator encl xc: File No. MI99 -0203 Reid iddleton January 4, 2000 File No. 26 -99- 005- 022 -02 Mr. Duane Griffin City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Subject: Building Permit Plan Review - Final Submittal US West Wireless Bow Lake Transfer Station (MI99 -0203) Dear Mr. Griffin: We reviewed the proposed project for compliance with the structural provisions of the 1997 Edition of the Uniform Building Code as amended and adopted by the City of Tukwila. The applicant has responded successfully to our comments. Enclosed are the drawings, structural calculations, geotechnical report, and correspondence from the engineer for your records. If you have any questions or require any additional clarification, please call. Sincerely, Reid Middleton, Inc. Da id B. S anson, P.E., S.E. Dir ctor, Structural Engineering Group bjr\26se \planrevw\ ukwila\99VO22r2.doc\bbh Enclosure cc: Kenneth D. Camp, KDC Architect/Engineer Catherine Tolosa Biao Huang, E.I.T. Plan Review Engineer Engineers Planners Surveyors Washington Oregon Alaska Reid Middleton, Inc. 728134th Street SW.. Suite 200 Everett, WA 98204 Ph:' 425 741 =3800 Fax: 425 741.3900 it - IJD[ I. i.� PACIFIC CORPORATION January 3, 2000 David B. Swanson Biao Huang Reid Middleton, Inc 728 134th Street SW Suite 200 Everett, WA 98204 Subject: Building Permit Plan Review- First Submittal US West Wireless Bow Lake Transfer Station (MI99 -0203) File No. 26- 99- 005- 022 -01 Dear David Swanson and Biao Huang, This letter is in response to the November 29, 1999 letter requesting additional information for review of the building permit. Enclosed are the following: 1. Two full size copies of revised structural drawings (D -1 and D -2 sheets) and one copy of supplemental calculations 2. Details of the caisson foundation called out on calculation page 2. This is found on the updated D -2 sheet of the site plans 3. The concrete strength, reinforcing steel grade and the foundation design service load are called out on the updated D -2 sheets. 4. Also included is a letter dated December 13, from our Geotechnical consultants regarding the inconsistencies in the heights of the monopole in their report, and what is indicated on the drawings. If you have any questions or comments please contact me at 425 -652 -2132. Sincerely, Certit4 Teth6fA- Catherine Tolosa On behalf of US West Wireless US West Wireless Project 450 - 110th Avenue NE Room 209, Bellevue, WA 98004 JAN 3 ""t RFJD MMtn!), F•, J Zipper Zeman Associates, Inc. Geotechnical and Environmental Consulting Odelia Pacific Corporation 450 — 110th Avenue N.E., Room 209 Bellevue, Washington 98004 Attention: Mr. Rich Shoji J -477 13 December 199 • nitS Subject: Addendum to Geotechnical Engineering Report Proposed US WEST Wireless SEA 270 Cell Site Tower 18700 Orillia Road South Mount Vernon, Washington Dear Mr. Shoji: EDE OUE JAN 3 2000 REID MIDDLETON This letter supplements the 15 September 1999 Subsurface Exploration and Geotechnical Engineering Evaluation report (J -477) prepared by Zipper Zeman Associates, Inc. The report presents recommendations regarding the US West Wireless cellular communications facility proposed for construction at the above - mentioned address. The report references construction of a 45 -foot tall monopole. From our recent discussion with you, we understand that the current design reflects a 60 -foot tall monopole. The structure has not been moved from the location referenced in the geotechnical report. The conclusions and recommendations presented in the 15 September 1999 geotechnical report are appropriate for design and construction of the proposed 60 -foot tall monopole without the need for additional investigation or analysis, in our opinion. We appreciate the opportunity to be of service on this project. Should you have any questions regarding this letter, please do not hesitate to call. Respectfully submitted, Zipper Zeman Associates, Inc. C Cl] Lc2-0 David C. Williams Associate ifrfi`(j�,••r- Thomas A. Jones, P. E. Associate Reid iddleton November 29, 1999 File No. 26 -99- 005- 022 -01 Mr. Duane Griffin City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RECEIVED f\! ;,r 3 0 1999 V t OPMFNT Subject: Building Permit Plan Review - First Submittal US West Wireless Bow Lake Transfer Statiotj (M199,,;= 0203), Dear Mr. Griffin: We reviewed the proposed project for compliance with the structural provisions of the 1997 Edition of the Uniform Building Code as amended and adopted by the City of Tukwila. The following comments should be addressed by the permit applicant. A copy of this letter was forwarded to the project contact for your convenience. 1. The following list of comments should be responded to in itemized letter form. The permit applicant should have the Engineer of Record respond and resubmit two copies of revised structural drawings and one copy of supplemental calculations. All information should be submitted directly to Reid Middleton, Inc. 2. Details of the caisson foundation called out on calculation page 2 should be shown on the structural drawings. In addition, the bolt size for the equipment cabinet mount should called out in the drawings. 3. Concrete strength, reinforcing steel grade, and the foundation design service load should be called out on the drawings. Corrections and comments made during the review process do not relieve the project applicant or designer from compliance with code requirements, conditions of approval, and permit requirements; nor is the designer relieved of responsibility for a complete design in accordance with the laws of the state of Washington. This plan review check is for general compliance with the Uniform Building Code as it relates to the project. If you have any questions or require any additional clarification, please call. Sincerely, Reid Middleton, Inc. avid B. Swanson, P.E., S.E. Director, Structural Engineering Group bjr \26seplanrevw\tukwila\99\t022r 1.doc\bbh cc: Kenneth D. Camp, KDC Architect/Engineer Catherine Tolosa Biao Huang, E.I.T. Plan Review Engineer Engineers Planners Surveyors Washington Oregon Alaska Reid Middleton, Inc. 728 134th Street SW Suite 200 Everett, WA 98204 Ph: 425 741.3800 Fax 425 741.3900 l a: City of Tukwila (ttEY1+'kSl,•,Yl'f1rY f.'!!. x,pra r,,a.1y1 V:T!t:S�A1 John W. Rants, Mayor Department of Community Development Steve Lancaster, Director PRELIMINARY REVIEW COMMENTS FILE: MI 99 -0203 APPLICANT: US West Wireless ADDRESS: 18700 Orillia Rd S. DATE: November 19, 1999 The Department of Community Development, Planning Division, has completed its review of the application materials you submitted on November 9, 1999. The following comments and / or corrections must be addressed before we can recommend approval of your permit: 1. The September 15, 1999 Geotechnical Report by Zipper Zeman Associates calls for a 45 foot monopole, while the Planning Commission approved a 60 foot monopole. Please revise the geotechical report to address requirements for a 60 foot monopole or revise your plans to construct a 45 foot monopole to support the Geotechnical Report. Please be aware that you will probably receive comments and/or corrections from other City departments as well. When you re- submit your corrected plans for further review, your re- submittaI must respond to the comments of all City departments concurrently. You will know when you have received the comments from all departments involved in the review and approval of your project when you receive a "Correction Letter" from the City's Permit Coordinator. The Permit Center cannot accept your re- submittal until after you have received a Correction Letter reflecting all departmental comments and correction. In the meantime, if you have any questions regarding the Planning Division comments and corrections, please contact Michael Jenkins at (206) 431 -3670. If you have any other questions regarding the status of your permit application, please contact the Permit Center at (206) 431- 3670. cc: Permit Center Reviewing Departments C City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director November 17, 1999 Dave Swanson, P.E. Reid Middleton 728 - 134th Street SW, Suite 200 Everett, WA 98204 RE: Structural Review US West Wireless — Bow Lake (M199 -0203) Dear Mr. Swanson: Please review the enclosed plans and documents for structural compliance with the 1997 Uniform Building Code. If you should have any questions, please feel free to contact me at (206)431 -3672. Brenda Holt, Permit Coordinator encl xc: Permit File No. MI99 -0203 PACIFIC! CORPORATION November 8, 1999 City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 To Whom It May Concern: h On behalf of US WEST Wireless L.L.C., I hereby submit the attached Miscellaneous Permit application for the US West proposal for a monopole at the Bow Lake Transfer Station. The cost of this proposal is $50,000 Approval of these application would allow US West Wireless to develop a new monopole at the this location thus providing needed coverage for the area. Please find the following materials needed for the application: Miscellaneous Permit Application Full size site plans (4) Reduced site plan (1) Soils reports (4) Structural report (4) Please feel free to contact me at (425) 652 -2132 if you have any questions. Sincerely, IVA Catherine Tolosa On behalf of US West Wireless L.L.C. US West Wireless Project 450 - 110t Avenue NE Room 209, Bellevue, WA 98004 PACIFIC CORPORATION 18700 Orillia Rd., S ADDRESS OF SUBJECT PROPERTY Tukwila, WA, 98178 CITY, STATE, ZIP I, /,/u.:"(e( f � � �'Y , hereby certify that I am the representative of the county property which is the subject of an application for the City of Tukwila. I further certify that I am authorized to allow Odelia Pacific Corporation, on behalf of U.S. WEST Wireless, L.L.C. to apply for and to submit applications and obtain approval for the items contained within the attached Conditional Use Permit application. Odelia Pacific Corporation, on behalf of U.S. WEST Wireless, L.L.C. is the "applicant" for this permit and shall remain the applicant for the duration of the permit or-approval unless subsequent written certification is provided. I certify that the foregoing is true and correct. Signed: ! /4-�f King County Representative DATE SIGNED .4 «46 US WEST PROJECT 450 11014 Ave NE Bellevue, WA 98004 (425) 451 -6555 FAX (425) `451= 6310 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI99 -0203 DATE: 1 -11 -2000 PROJECT NAME: US WEST WIRELESS Original Plan Submittal Response to Incomplete Letter# XX Response to Correction Letter # 1 Revision # _ After Permit Is Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Plannin`bivision )43-00 Permit Coordinator ■ DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ri DUE DATE: 1 -13 -2000 Not Applicable TUES /THURS ROUTI : Please Route Structural Review Required n No further Review Required C REVIEWER'S INITIALS: DATE: APPROVALS OI CORRECTIONS: (ten days) DUE DATE 2 -10 -2000 Approved Approved with Conditions ri Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) El REVIEWER'S INITIALS: DATE: \PRROUTE.DOC sion PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: MI99 -0203 DATE: 11 -9 -99 PROJECT NAME: US WEST WIRELESS BOW LAKE XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # , After Permit Is Issued DEPARTMENTS: Building Division ®, AwG I2 -V -4 Public Works , 1��YYi 1444.. II-11 rev Prevention tion -qcf Structural kP I-t4- two gip Pjannjng Division 11--M A Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 11 -16 -99 Not Applicable n Comments: TUES /THURS ROUTI G: Please Route Structural Review Required 1-7( No further Revi REVIEWER'S INITIALS: DAT i w Required n APPROVALS OR CORRECTIONS: (ten days) Approved ri Approved with Conditions Not Approved attach comments) e/OVVeL 4 1 WA/LW ► —z ) REVIEWER'S INITIALS: DA : E DATE 12-14 -99 CORRECTION DETERMINATION: Approved DUE DATE Approved with Conditions ri Not Approved (attach comments) C REVIEWER'S INITIALS: DATE: \PRROUTE.000 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 p, r. 314ti- 'c ^ ;tj:,+,..;•�`,a}en,,:'';S.'� 'Y,,:a'f,'f., Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: JO mActet - 10 , jOOo Plan Check/Permit Number: MI99 -0203 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued Project Name: US WEST WIRELESS Project Address: 18700 Orillia Road South Contact Person: Catherine Tolosa Phone Number: Summary of Revision: LeAkeg doted, De(',viy)b cp. morn ,pp-er Zemau■ errorx, . lnC, reriing -H +5 --Rat }r,tk monopole) Cr-lhe oe kechn(cc (e(ao * , end 'in corKde xilS LAI* -ht 60 fvo-t monoett ran -�rre drawu'gs CITY OF TUKWILA JAN 1 0 2000 PONT CiNTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: C35-1 t 1 N — Entered in Sierra on f--1 D ^ 2.606 Jan -18 -00 03:40pm From -US WEST r ^QLESS LLC $4254516310 Ms 1):1-1,1. Am' Uurla. 1'MA...e T -433 P.02/02 F-922 DI-1'ART'11iNT OF LABOR AT ) 1NI ?uSTK11:S REGISTERED AS PROVIDED SY LAW AS CONST CONT GENERAL - :, REGIST .. *;3 war.: DATE CCOI.;.. AMERII'210CG'05 /01/2000 EFFECTIVE :OATS= _;:.112/07/1979 AMERICAN LINE BUILDERS INC 246 TUCANNON RD DAYTON WA 99328 rie S ; l►qc► WN7 r 1 F.2' us: iglu 10971 C. Demo Ana Dianiar Cauf►catc REGISTERED AS PROVIDED BY LAW AS CONST • CONT GENERAL REGIS?. it EXP. DATE CCO1 AKRRZI•210CG 05/01/2000 $Fner.IVE DATE 02/07/1979 AMERICAN. LINE BUILDERS INC. 246 TUCANNON RD DAYTON WA 9932 Sigm lssu y D NA OF LABOR AND WGUSZRIES _ r Please Remove And Sign Identification Card Before Placing In Billfold I certify that this to a copy of the original licease,.fANBIfl*210CG, which expires oe 5/1 /2000. D.J. F •ae, Vice President Aserican Line Builders, Iac. 111111/s414, Not ry Public in and for the Stets of Ma �' 'PS% •. AR• - tTamer 's s, PueuC . Ny commission expires 06/19=P171 I�� . is %AIM%'