Loading...
HomeMy WebLinkAboutPermit MI99-0222 - PAWN X-CHANGE - REROOFMI99 -0222 14121 Tukwila International Blvd. Pawn X-Cbartge City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MISCELLANEOUS PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 161000 -0140 Address: 14121 TUKWILA INTERNATIONAL BL Suite No: Location: Category: NSFR Type: MISCPERM Zoning: Const Type: Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: Permit No: • Status: Issued: Expires: MI99 -0222 ISSUED 12/09/1999 06/06/2000 Occupancy: STORE UBC: 1997 Fire Protection: .0 South: .0 East: .0 West: .0 Sewer: N/A Slopes: N Streams: Contractor License No BRROOI *066QA OCCUPANT PAWN X- CHANGE Phone: 14121 TUKWILA INTERNATIONAL, TUKWILA WA 98188 OWNER PEZZELLA PAUL SR Phone: (206)000 -0000 1935 J ST NE, AUBURN WA 98002 CONTACT GEORGE RICHART Phone: 206 -248 -2250 18040 DES MOINES DR #103, BURIEN WA 98148 CONTRACTOR B R ROOFING INC 18040 DES MOINES MEM DR, SEATTLE WA 98148 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: REMOVE EXISTING ROOFING, REINSTALL SAME KIND FIELDS SPEC. #AAW- 325 -MS ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ 8,175.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fi l l : Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Mairi Extension: N Private: Public: Storm Drainage: N Street Use: N Water Main Extension: N Private: Public: ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 154.25 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:! 00. Date: 11"9' 99 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether' specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I, am authorized to sign for and obtain this development p�srmit. Signature:___ c.= Pr i nt Name :CSC_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: )9,-9-q)? CITY OF TUKWILA Address: 14121 TUKWILA INTERNATIONAL BL Permit. No: MI99-0222 Suite: lenant: Status: 'ISSUED lype: MISCPERM Applied: 12/091999 Parcel It: 161000-0140 Issued: 12/09/1999 **********k**************************************************************** Permit Conditions: • , 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. All permits, inspection records; .and approved plans shall be available at the job site prior to the start of any con- , struction. These documents are to be maintained and avail- able until final inspection apProval is granted. 3 Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical ,work will be inspected by that agency (248-6630). Plumbingpermits shall be obtained through the Seattle-Kling County Department of Public. Health. Plumbing will be inspected by that agency, including all gas piping (296-4722). 5. All mechanical work shall be under separate permit issued. by the City of Tukwila. 6. All construction to be done in conformance with approved ' plans and requirements of the Uniform :Building Code ,(1997 Edition) as, amended, Uniform Mechanical Code (1997 Edition), and :Washington State Energy Code (1997 Edition). 7. Validity of Permit. The issuance of a permit or approval ,of plans, specifications, and computation hall not be con- ' ‘strued to be a permit for, or an ,approval' of, any violation oF any, of the provisions of the building code or of any other ,ordinance of the jurisdiction. %No permit presuming to,,J, give authority to violate or cancel Lhe provisions,of this " code shall be valid. 8 A statement from the roofing contractor verIfy:Ing Fire • • • retardant (..1d, of roof will he' required prior to findi inspection (see attached procedure). CITY OF TUKWILA REROOF CONDITIONS Permit No MI99 -022' Project Name: PAWN X- CHANGE Address: 14121 TUKWILA INTERNATIONAL. f3L. Suite: ** ********************************************* *** *A• * *Ar1*** ** * ** *** * ** * * *** THE FOLLOWING CONDITIONS WILL. APPLY TO. RE- -ROOF PERMITS: 1.. All re-roofing projects will be accomplished An compliance with Appendix Chapter:-.15 of the Uniform Building Code . (UBC);. 2. Inspections: A. New roof coverings shall not be applied without first obtaining a pre-roofing inspection from the Building Division and written approval from the Building Inspector. The pre-roofing inspection shal 1 pay particular attention to evidence oF accumulation of water. Where extensive pond i ng of water is apparent, . an analysis of the roof structure For compliance with Section 1506, UDC, shall be made and corrective :measures, such as relocation of roof drains or scuppers, reslopirig of the roof or structural changes, shall be accomplished. An inspection covering the above listed topics ' prepared by a qualified special inspector,. as determined by the Building Official, may accepted in lieu or the prey- inspection by the Building Inspector. B. A final inspection and approval shall be obtained from the Building Division when the re-roofing ,is complete.. As a condition of the final inspection For roofs that require a fire retardant roof covering under the provisions OF Table 15-A, 1994 UEiC, the roof installer shall provide the inspector with a written statement, indicating . the following (or something similar): 1 HAVE INSTALLED A ROOF MEMBRANE ASSEMBLY, INCLUDING" INSULATION IF APPLICABLE, CONSISTING OF (MANUFACTURER),, SPECIFICATION #, , DATA SHEET ENCLOSED, WHICH MEETS OR EXCEEDS THE .REQUIREMENTS FOR CLASS A OR CLASS 13 ROOFS. THIS ROOF WAS INSTALLED AT (ADDRESS) , UNDER CITY OF TUKWILA PERMIT NO. ('(he statement shall include the name of the roofing company 'that- installed the roof, signature of installer and date.) CITY OF 'JKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Proje Nametlenant: a. la .. to . J Description of work to be done (please be specific): j "b AALt) Value of Construction: �`I'7. oa Site Address : 112 / 1 City Stat i r Tax Parcel Number: Property Here t� �� — `~ ! ty Sta Zi 9e�le}!ue— t' i i5 Phone: ( ) Fax #: ( ) ��(� �Lj F-- j (, Street Address. c Lk') ) l- Contractor: Q lb.1 n _1c-. Phone: ) Aim - 0 Sewer -0 Street Address: )3oLic i_s X10 ,5 c� i n City State/Zip: Low, i& Ltsl ee� Fax #: (a0t'.) ay - ,� Architect: Phone: ( ) Street Address: City State/Zip: Fax #: ( Engineer: Phone: ( ) Street Address: ,.;; , City State/Zip: Fax #: ( Contact Person: Phone: ( Street Address: City State/Zip: Fax #: ( MISCELLANEOUS PERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (please be specific): j "b AALt) -e S _SVe>v, rnS Will there be storage of flammable/combustible hazardous material in the building? ❑ yes 71 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating qua titles & Material Safety Data Sheets ❑ Above Ground Tanks ID Antennas/Satellite Dishes ID Bulkhead/Docks Commercial Reroof ❑ Demolition ❑ Fence ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Facilities ❑ Tree Cutting APPLICANT REQUEST FORMISCELtANEOUS PUBLIC; WORKS PERMITS ❑ Channelization /Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ❑ Water Meter /Exempt # ❑ Water Meter /Permanent ❑ Water Meter Temp # ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 _sq. ft.grading/clearing ❑ Sanitary Side Sewer #: " " "' ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Size(s): Size(s): Size(s): Est. quantity: gal Schedule: 11 Moving Oversized Load/Hauling MONTHLY SERVICE'8(LLINGS:TO:r.` " y Name: 1 Phone: Address: City / State/Zip: 0 Water 0 Sewer 0 Metro 0 Standby WATER,METER DEP.OSIT/REFUND "BILLING: Name: Phone: Address: City /Sta e/Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I Date apilncCi` 99, Date applep lApplicarRilals) I A11 M15( / 1 1 AN! 01l.S P1 RM 11'1'!!( A /!ONS Al//.51 R1 .S////,11//// , ' / / / / / / / / / 0 1 / 74 )■••1 `. AlibRA►141011l HiL *AT A LEGIBLE SCALE AND NEATLY DRAWN ' r i34 .w%yd/'1�. t7 .7 t,� / 3 '. J A /`r BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT > STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER > CIVIL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ titliihlli /WI I( /SCION /NI) RI(1IJIREI) ( III( RI Mt, IOlt , Above Ground Tanks/Water'Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height.to. diameter or width which . exceeds 2:1 I'II1111I Ri VII b1' Submit checklist No: M-9 ❑ Antennas /Satellite Dishes Submit checklist No: M -1 ❑ Bulkhead /Dock ' Submit checklist,' . No: M -10 El Commercial Reroof . { Submit checklist , No M -6 ." ❑ :Demolition Submit checklist No: M -3 ❑ Fences - Over.6,feet in Height Submit checklist No: M -9 ❑ .Land Altering/Grading/Preloads . t I Submit checklist No: M -2 ❑ Miscellaneous .Public Works Permits . Submit checklist No: H -9 ❑ Manufactured Housing.(RED INSIGNIA ONLY),' .. ; ` Submit checklist 'No: M-5 ❑ Moving Oversized Load /Hauling, w° 'y °' Submit checklist No M -5 ❑ tot( Lots, ;Submit checklist No M-4.: ❑ Retaining Walls- Over 4 feet in height Submit checklist No M -1 ❑ Temporary Facilities Submit checklist . No: M-7 ❑ Tree Cutting Submit checklist . No: M -2 ❑ Current copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building :Owner /Authorized Agent If the applicant is. other. Chain :the owner, registered architect/engineer,. or contractor: licensed:by the State of Washington, a notarized letter from,thelproperty owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this. submittal: ' I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PER JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING. OWNER OR AUTH • ' IZ is AG T: Date: 1z-3r.9% l t Signature: Print name�+ � Phone: 9 ) rr��))IIp(y� ^^A Fax #: t` Address:\ b ; S % b� ICity /State/Zip %v im LA W)q r (? • M� .� .. . °! ^. • . --r, _nv..ri..,. 1T,?nov- ^:771 ;1 If :,.+ .:iiC*iC****7tiil******* SIC*** *** * ******** *1011111**** I **i :i(**7�*** * *'*i�C�f�C:f*** CITY OF TUKWILA, WA m �' 9C�.. ('� TRANSMIT **********•*****•****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TRANSMIT Number: R9800201 Amount: 154.25 12/09/99 16 :37 Payment Method: CHECK Notation: BR ROOFING INC Init: WER Permit No: MI99 -0222 Type: MISCPERM,MISCELLANEOUS PERMIT Parcel No: 161000 -0140 Site Address: 14121 TUKWILA INTERNATIONAL BL Total Fees: 154.25 This Payment 154.25 Total ALL Pmts: 154.25 ************************************ * * *** * * * * * * * * ** * * * * * * * * * ** * * *' Account Code . Description Amount. 000/322.100 BUILDING - RES 149.75 000/386.904 STATE BUILDING SURCHARGE 4.50 .: n.: Ji. arewA ti4 4 • rnrwt .!.':.'i;.41'; .ier. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Project:en raLtin )( - C "y -e Type of Inspection: v1 I Address: )L -t1)..1 1tili- 1rt1- Date called: S--9 -00 (4111 instructions`. G (� }1 )�? r' e �' m� Date wanted: 00 S Requester: � PC)Ir �� -P ry r A ' Phone: pproved per apl cable codes. Corrections required prior to approval. VA a COMMENTS: '�� '' —r ,C t. Inspecto Date: $47.d0.REINSPECTION FEE REQ RED. Prior t&inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection. I Receipt No: 1 Date: • INSPECTION RECORD fi Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Project q) IZIWIA ' x- C ka oTe Type of Inspection:1-) ... 1) rre iCe v00+ Address: 0-11 ..1 l'OV.t.v1. kA IK\fr . Date called: 1)......cr 7i 0)4 ti,41"-d Special instructions: Date wanted: - - P.m. Requester: Gforce Phone:).049_ RApproved per applicable codes. 1:1 Corrections required prior to approval. COMMENTS: 0 F7A.J4<-- ?—e,OF 0)4 ti,41"-d / Datpx $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee riust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 1 Datil! MINERAL CAP BUR RO OVER NAMABLE DECK t SHEET SYSTEM INSTALLED AMBIENT ASPHALT OVER 10132" COMBUSTIBLE DECKS J.L. Class "A" up to 1R" slope APPLICATION RECOMMENDATIONS Roof deck shall be firm, dean, dry and smooth. Apply Fields F52 GlasBase Fiberglass Type 11 Base Sheet so that the flow of water is over of parallel to, but never against the laps. It shall be lapped 2" on sides and 6" on ends. Extend base sheet 2" above the top of the cant strip. Nail the base sheet 9" on center on the laps, and stagger nail two rows 18" on center, 12" distant from each edge. ALTERNATE METHOD: Mechanically attach with approved "tape and staple" method. Rows of tape shall be installed 12" on center. Staple spacing shall comply with fastener manufacture's requirements. Install an extra layer of Fields F52 GlasBase in valleys and waterways. This 36" wide layer shall extend at least 8" up the inclines out of the valleys, set in a uniform layer of Fields F100 PowrCoat Asphalt Coating and Adhesive at a rate of 3.5 gallons per 100 square feet of roof area. This ply shall be laid prior to the application of the roofing plies. Install two plies of Fields F54 GIasPIy4 FiberglassType IV Ply Sheet in shingle fashion, lapping 19" with a 17" exposure. Starter strips of 18" and 36" shall be used and the second full sheet shall be laid with a maximum exposure of 16 ". Embed the full width of the ply sheet into Fields F100 PowrCoat Asphalt Coating and Adhesive at a rate of 3.5 gallons per 100 square feet of roof area. The ply shall be lightly broomed as it is applied. The ply sheet surface to receive the specified Fields roof coating shall be uniform, clean, smooth and dry. Properly repair any fishmouths, buckles dry laps or damage prior to the application of the mineral cap sheet. Cut Fields F58 GlasCap Fiberglass Cap Sheet into 12' lengths, and allow to relax. Apply F58 GlasCap sheet so that the flow of water is parallel to but never against the Zaps. Embed F58 GlasCap sheet into a solid mopping of F100 PowrCoat applied at a uniform rate of 3.5 gallons per 100 square feet of roof area. Set neatly into place with 2" side lap and 4" end laps. Adjacent end laps shall be at least 3' apart. There must be complete adhesion between the F58 GlasCap sheet and the asphalt. SPECIFICATION NUMBER GlasBase & GIasPIy4: AAW- 325-MS MATERIAL REQUIREMENTS per 100 square feet. 1. F52 GlasBase 1 ply 2. F54 GIasPIy4 2 plies 3. F100 PoveCoat 3.5 gallons 4. F58 GlasCap 1 ply 5. Accessories & Flasfmg Materials as required All applcadon recommendations and General Requirements included h this manual are considered part of this specification. Al guaranteed roof systems must be flashed according RECEIVED to the "Flashing Details" section of this manual. CITY OF TUKWILA DEC 9 1999 PERMIT CENTER FIELDS CORPORATION BR ROOFING, INC. 18040 Des Moines Memorial Dr., Ste 103, Seattle, WA 98148 • Phone (206) 248 -2250 CITY OF TUKWILA BR Roofing, Inc. has installed a roof membrane following Fields specification #AAW- 325 -MS, data sheet enclosed which meets or exceeds the reguirements for a class 'A' roof. This roof was installed at: PAWN X- CHANGE 14121 International Blvd. Tukwila, Wa. Under city of Tukwila Permit #MI99 -0222 If you have any further questions call George Richart at 206 - 248 -2250. RECEI'VEfD CITY O r TUKWILA MAY 1 7 2000 PERMIT CENTER a,M Ges " &., ) 2-1 0\) -?CtC\ CgLAC-e■C'k'n ?C\t.14 6)\ U'N&es— 1 \Aks e-X&S'61l� 1'()0 1c(-)-1nf\ /0e_ -)-\NckV D.tv\c,(A- t\ op RECEIVED CITY OF TUKWILA DEC 9 1999 ... -..t u� ncnarco