Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-005 - OUTBACK STEAKHOUSE - INTERIOR UPGRADE
OUTBACK STEAKHOUSE 16510 SOUTHCENTER PY EXPIRED 09 -05 -12 D12-005 City oilkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 6437300010 Address: 16510 SOUTHCENTER PY TUKW Suite No: Project Name: OUTBACK STEAKHOUSE Permit Number: D12-005 Issue Date: 01/26/2012 Permit Expires On: 07/24/2012 Owner: Name: CHA SOUTHCENTER LLC Address: 16500 SOUTHCENTER PKWY , SEATTLE WA 98188 Contact Person: Name: MICHAEL CABE Address: 1800 136 PL NE, #100 , BELLEVUE WA 98005 Phone: 425 747 -3177 Contractor: Name: KIRTLEY -COLE ASSOCIATES LLC Phone: 425 - 609 -0400 Address: 1010 SE EVERETT MALL WY, SUITE 102 , EVERETT WA 98208 Contractor License No: KIRTLAL951BC Expiration Date: 01/03/2013 Lender: Name: Address: DESCRIPTION OF WORK: INTERIOR DECOR UPGRADE, LIGHT FIXTURE UPGRADE (LESS THAN 60 %), REMOVE SUSPENDED CEILING GRID IN RESTROOM AND REPLACE WITH GWB HARD -LID, REPLACE WATER CLOSETS AND LAVS (LIKE FOR LIKE), AND REPLACE FLOORING AT FRONT CUSTOMER WAITING AREA. NO EXTERIOR WORK IS PROPOSED. Value of Construction: $42,000.00 Fees Collected: $1,387.12 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: A2 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12-005 Printed: 01 -26 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N l0 Permit Center Authorized Signature: LAyAL Date: I hereby certify that 1 have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo I• - ce of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: _ Date: 1/ t6 / Z Print Name: TaYt N (ZA N l Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All food preparation establishments must have Seattle /King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle /King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On doc: IBC -7/10 D12 -005 Printed: 01 -26 -2012 work requiring Health Department approval. the contractor's responsibility to have a sedans approved by the agency on the job site. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets, ceilings or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 17: Maintain fire alarm system audible /visual notification. Addition/relocation of walls, ceilings or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 22: Public Works 23: A separate Public Works construction permit shall be obtained to install a Reduced Pressure Principle Assembly on existing domestic water service. doc: IBC -7/10 D12 -005 Printed: 01 -26 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. u . Project No: Date Application Acc ►ted: mate Application Bxpires. CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION v4-1111 King Co Assessor's Tax No.: Site Address: 16510 Southcenter Parkway Suite Number: Floor: 4333.606.1.682 Tenant Name: Outback Steakhouse PROPERTY OWNER Name: Merrick Lentz Arch / Michael Cabe Name: CHA Southcenter LLC 551776 City: Bellevue State: WA Zip: 98005 Address: 16500 Southcenter Parkway Email: mikec @mlarch.com City: Seattle State: WA Zip: 98188 CONTACT PERSON — person receiving all. project communication Name: Merrick Lentz Arch / Michael Cabe Address: 1800 136th Place NE, #100 City: Bellevue State: WA Zip: 98005 Phone: (425) 747 -3177 Fax: Email: mikec @mlarch.com GENERAL CONTRACTOR INFORMATION Company Name: Kirtley -Cole Assoc., LLC Address: 1010 SE Everett Mall Way, #102 City: Everett State: WA Zip: 98208 Phone: (425) 609 -0400 Fax: Contr Reg No.: KIRTLAL951BC Exp Date: 01/13/2013 Tukwila Business License No.: H:\Applications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh New Tenant: ❑ Yes m ..No ARCHITECT OF RECORD Name: N/A Company Name: Merrick Lentz Architect Company Name: N/A Architect Name: Michael Cabe Address: 1800 136th Place NE, #100 City: Bellevue State: WA Zip: 98005 Phone: (425) 747 -3177 Fax: Email: mikec @mlarch.com State: ENGINEER OF RECORD Name: N/A Address: Company Name: N/A Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 42,000 Existing Building Valuation: $ 1,300,000 Describe the scope of work (please provide detailed information): Interior decor upgrade, light fixture upgrade (less than 60 %), remove suspended ceiling grid in restroom and replace with gwb hard -lid, replace water closets and lays (like for like), replace flooring at front customer waiting area per plan. No Exterior Work is Proposed. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All' Building Areas in Square Footage Belo PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes d No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:\Applications \Forms- Applications On Line \20l I Applications\Pemit Application Revised - 8 -9 -I Ldocx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per °:; IBC Type of Occupancy per IBC 1' Floor 6,648 3,381 0 0 V -B A-1 2nd Floor 0 3rd Floor 0 Floors 1 ' thru 1 6,648 Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes d No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:\Applications \Forms- Applications On Line \20l I Applications\Pemit Application Revised - 8 -9 -I Ldocx Revised: August 2011 bh Page 2 of 4 • PLJBLICWORKS PERMITt INFORMATION' 206 433T01V, 0 c•< Scope of Work (please provide detailed information): No Exterior work to be done. This is an Interior decor upgrade only: Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ::.Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District DI ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑, : Renton ❑ Sewer Availability Provided ❑ :: Renton ❑ : Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ::.Bond ❑ :: Insurance ❑ .. Easement(s) ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ :::Hold Harmless = (SAO) ❑ .:Hold Harmless = (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction /Excavation /Fill Right -of- -way ❑ Non Right -of -way ❑ ...Total Cut _ cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ :: Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ::.Water Only Meter Size - -- -- - WO # ❑ ... Deduct Water Meter Size ❑ :..Sewer Main Extension - -- - - - Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund /Billing: Name: Mailing Address: Day Telephone. City State Zip H:\Applications \Forms - Applications On Line \2011 ApplicationsWermit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 3 �f 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: Print Name: Merrick Lentz Arch. / Michael Cabe Mailing Address: 1800 136th Place NE, #100 H:`.Applications\Forms- Applications On Line X2011 Applications\Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Date: 01/04/2012 Day Telephone: (425) 747 -3177 Bellevue WA 98005 City State Zip Page 4 of 4 � r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 6437300010 Permit Number: D12-005 Address: 16510 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 01/04/2012 Applicant: OUTBACK STEAKHOUSE Issue Date: Receipt No.: R12 -00297 Initials: User ID: WER 1655 Payment Amount: $842.45 Payment Date: 01/26/2012 03:17 PM Balance: $0.00 Payee: KIRTLEY -COLE ASSOCIATES LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 035616 842.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 837.95 640.237.114 4.50 Total: $842.45 doc: Receipt -06 Printed: 01 -26 -2012 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.zov RECEIPT Parcel No.: 2623049127 Permit Number: D12 -005 Address: 16510 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 01/04/2012 Applicant: OUTBACK STEAKHOUSE Issue Date: Receipt No.: R12 -00024 Initials: User ID: Payee: JEM 1165 Payment Amount: $544.67 Payment Date: 01/04/2012 02:56 PM Balance: $842.45 OUTBACK STEAKHOUSE - SOUTHCENTER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6190824 544.67 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 544.67 Total: $544.67 doc: Recent -06 Printed: 01 -04 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tz., (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P/2 -ads Project: C 1/r4 6(P K. Type of Inspection: f"! K./"? / Address: / 65/ Sa . <'•✓1 P`i Date Called: Special Instructions: Date Wanted:. y - / Z (a:m. P.m. Requester: Phone No: El Approved per applicable codes. ®;Corrections required prior to approval. COMMENTS: I / -- 442 f) id✓ee" c� n R NVECTION FEE REQUIRED Prig to next inspection. fee must be ai 6300 Southcenter Blvd., ite 100. Call to schedule reinspection. .t4 INSPECTION RECORD Retain a copy with permi INSPECTION NO. f- I CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 t. PERMIT NO. DIVISION (206) 431 -3670 �rz -otoS Project: aY&ic&. Sr. UoJSE Type of Inspection: fry ,nG, 5 kAi-orK o,, olu..48.1 Address: I 1.1 C /0 3C,0 rev Date Called: A.-- W A _3 ` r , A F,2 ( ,Ap P /3 Special Instructions: 1 Date Wanted: . I- 21--7 p.m. Requester: ' Phone No: Approved per applicable codes. orrections required prior to approval. 67 COMMENTS: 5 kAi-orK o,, olu..48.1 ..* 6.1)1) 0,A OrK �c.-:(),37. 0 k " , A.r�� ( -> r o �� AA D A AL., LI A.-- W A _3 ` r , A F,2 ( ,Ap P /3 _44 , r:: A L. 4 o a J4 ()A rf %4- c- 0A' e..--c . c4 u1) /,),)�/wr LR1 % Nk 1 A_ ... 7C`-%1 /t " [ ^•l1 e 11 ❑ REINSPECTION FEE REQUIRED. P for to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. J INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b1 a -o os —S vo I PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila 98188 206 - 575 -4407 Project: 0,A-66,k. S-i ec,k &'5 e Type of Inspection: sPerl< F-0,4 i ri,, r, t,„ Address: /0"/ o 5 L P k �-Y Suite #: Contact Person: Special Instructions; Phone No.: 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 5e), k Fo „w ( o1 Fi,-G k' ok Needs Shift Inspection: / Sprinklers: Date: 9 - /(/-/ > Fire Alarm: 1 Hood & Duct: Monitor: Pre -Fire: �� Permits: Al % Occupancy Type: Inspector: / )- I i Date: 9 - /(/-/ > Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: Cjy: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -123.05- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: p T pe f Inspection: (\.... _, Address: 46�/ D S 1.0,1,#(./_ Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. KiCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor:. • Pre -Fire: Permits: Occupancy Type: No 5iPR()%)14.(.Li- 09/Viw s o 5\4-€ it) o Coo net- . 5- F-5P•G elt 00) - tD _ 5 Pr:,uk --LIx( C-42.,e-i1c orZ . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor:. • Pre -Fire: Permits: Occupancy Type: i Inspector: ,cy,^ S'oj-- Date: E-19// Z Hrs.: t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 08 -01 -2012 City of Tukwila Department of Community Development MICHAEL CABE 1800 136 PL NE, #100 BELLEVUE WA 98005 RE: Permit No. D12 -005 OUTBACK STEAKHOUSE 16510 SOUTHCENTER PY TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/05/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/05/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, File: Permit File No. D12 -005 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 • Gity of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 24, 2012 Michael Cabe Merrick Lentz Architect 1800 136 Place NE, #100 Bellevue, WA 98005 RE: Correction Letter #1 Develop. _ "Oermit Application Number D12 -005 Outback Steakhouse —16510 Southcenter Py Dear Mr. Cabe, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire, and Planning Departments have no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, encl File No. D12 -005 W:\Permit Cen ter \Correction Letters\2012\D12 -005 Correction Letter iil.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 1 PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards PROJECT: Outback Steakhouse REVIEW #: 1 PERMIT NO: D12-005 PLAN REVIEWER: Contact Joanna Spencer at (206) 431 -2440 if you have any questions regarding the following comments. 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. Since the project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of an approved backflow prevention on the fire line and the domestic water supply to the building. The City has determined that the subject building has deficiencies on domestic water service line only. a) Domestic Water Service A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing 1.5" permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Woks strongly recommends a power supply for the freeze protection enclosure. Please specify on your plan backflow size, manufacturer, and model number and submit a cut sheet of the proposed RPPA. There is an existing internal 3/4" RPPA for dishwasher that failed the annual test last October. The tester said it would be repaired and retested; however Public Works has not yet received a passing backflow test report. Please have this RPPA tested and submit passing test report to Public Works. A separate letter addressing the above backflow deficiencies was mailed to Southcenter Motel Hotel Ltd, c/o Poer Marvin F and Company, property owner on January 10, 2012. The Public Works Director will withhold issuance of this Tenant Improvement permit until the backflow issues for domestic water are resolved or the Permit Center receives plans for item la. Applicant can post a bond for item la in the amount equal to 150% of the design, installation, and testing cost of subject backflow, together with a letter stating the installation by a certain date. (W:PW Eng/other /Joanna Spen cer/D 1 2-005 PW) • City of Tukwila Department of Public Works January 9, 2012 Southcenter Motel Hotel Ltd c/o Poer Marvin F & Company 500 108`x' Ave NE, #780 Bellevue, WA 98004 -5580 RE: Outback Steakhouse Tenant Improvement 16510 Southcenter Pkwy, Tukwila WA Permit No. D12 -005 To Whom It May Concern: Jim Haggerton, Mayor Bob Giberson, P.E., Director In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross- connection control program to protect the public water system from contamination via cross - connection. Since the project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code, including installation of approved backflow prevention on the fire line and the domestic water supply to the building. The City has determined that the subject building has deficiencies on the domestic water and no deficiencies on the fire prevention or landscape irrigation lines. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works strongly recommends a power supply be provided for the freeze protection enclosure. On your site plan, please show the property line(s), street name, North arrow, building location, and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number. Submit RPPA cut sheet. There is an existing internal 3/4" RPPA for a dishwasher that failed the annual test last October. The tester said it would be repaired and retested; however, Public Works has not yet received a passing test report. Please have the backflow tested and submit passing test results to Public Works ASAP. I have enclosed Development Bulletins C5 and A9, which spells out design and installation requirements for cross connection control. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 433 -0179 • Fax: 206 - 431 -3665 • Southcenter Motel Hotel Ltd. Page 2 January 9, 2012 The Public Works Director will withhold issuance of the Outback Steakhouse Tenant Improvement permit until the Permit Center receives plans for installation and test results of subject backflow devices or a bond in the amount of 150% of the cost of design, installation and RPPA testing: If you opt to install, you may install under a separate permit or under a revision to this Tenant Improvement permit application. If you opt to install under the Tenant Improvement permit, you must supply the installation plans consisting of a schematic that clearly shows the location of the proposed RPPA in relationship to the property line(s), building perimeter and existing domestic water meter together with a construction cost estimate to the Permit Center as a revision to the Tenant Improvement permit application. Backflow installation will trigger a Public Works Type C Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for RPPA installation and backflow testing) when the application or revision to this TI is submitted. An additional 2.5% of subject construction cost will be assessed at the time of permit issuance. If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150% of the design, installation and testing cost, and 3) a letter stating your intent to install the backflow by a certain date. This must be done before the Permit Center issues the permit. I have enclosed Public Works Bulletins Al, A2 and C5 to help you. Please call Mike Cusick, Public Works Senior Water and Sewer Engineer at (206) 431 -2441 if you have any questions. Sincerely, Joanna Spencer Development Engineer JS:lw enclosures: Public Works Bulletins #A -1, A -2, A -9 and C5 Permit Application cc: Michael Cabe D12-005 Development file (W:PW Eng/Othcr /Joanna Spencer /Letter Outback 010912) vie kwila Department of Public Works January 9, 2012 Southcenter Motel Ilotel Ltd c/o Poer Marvin F & Company 500 108th Ave NE, #780 Bellevue, WA 98004 -5580 RE: Outback Steakhouse Tenant Improvement 16510 Southcenter Pkwy, Tukwila WA Permit No. D12 -005 Jim Haggerton, Mayor Bob Giberson, P.E., Director E CO New. o_ GOO P�R�iP To Whom It May Concern: In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. Since the project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code, including installation of approved backflow prevention on the fire line and the domestic water supply to the building. The City has determined that the subject building has deficiencies on the domestic water and no deficiencies on the fire prevention or landscape irrigation lines. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works strongly recommends a power supply be provided for the freeze protection enclosure. On your site plan, please show the property line(s), street name, North arrow, building location, and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number. Submit RPPA cut sheet. There is an existing internal 3/4" RPPA for a dishwasher that failed the annual test last October. The tester said it would be repaired and retested; however, Public Works has not yet received a passing test report. Please have the backflow tested and submit passing test results to Public Works ASAP. I have enclosed Development Bulletins C5 and A9, which spells out design and installation requirements for cross connection control. D 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 433 -0179 • Fax: 206 -431 -3665 South: enter Motel Hotel Ltd. Page 2 January 9, 2012 The Public Works Director will withhold issuance of the Outback Steakhouse Tenant Improvement permit until the Permit Center receives plans for installation and test results of subject backflow devices or a bond in the amount of 150% of the cost of design, installation and RPPA testing. If you opt to install, you may install under a separate permit or under a revision to this Tenant Improvement permit application. if you opt to install under the Tenant Improvement permit, you must supply the installation plans consisting of a schematic that clearly shows the location of the proposed RPPA in relationship to the property line(s), building perimeter and existing domestic water meter together with a construction cost estimate to the Permit Center as a revision to the Tenant Improvement permit application. Backflow installation will trigger a Public Works Type C Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for RPPA installation and backflow testing) when the application or revision to this TI is submitted. An additional 2.5% of subject construction cost will be assessed at the time of permit issuance. If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150% of the design, installation and testing cost, and 3) a letter stating your intent to install the backflow by a certain date. This must be done before the Permit Center issues the permit. I have enclosed Public Works Bulletins Al, A2 and C5 to help you. Please call Mike Cusick, Public Works Senior Water and Sewer Engineer at (206) 431 -2441 if you have any questions. Sincerely, Li Joanna Spencer Development Engineer JS:lw enclosures: Public Works Bulletins #A -1, A -2, A -9 and C5 Permit Application cc: Michael Cabe D12 -005 Development file (W:PW Eng/Other /Joanna Spencer /Letter Outback 010912) o s1 Q Joanna Spencer From: Mike Cabe <MikeC @mlarch.com> Sent: Thursday, January 12, 2012 8:02 AM To: Bob Benedicto; Joanna Spencer Cc: Michael Cusick Subject: Permit #D12 -005 Attachments: Tukwila- Outback - dishwasher - backflow- pass- 2012.pdf Attached is the backflow letter stating that a re -test was done and now passes. This is per the comment letter dated January 9, 2011 for the above referenced permit number (Outback Steakhouse). Respectfully, Michael Cabe Merrick Lentz Architect 1800 - 136th Place NE #100 Bellevue, WA 98005 0 - 425 -747 -3177 F - 425 - 747 -7149 www.miarch.com Scanned by MessageLabs 1 PERMANENT FILE COPY b I z Oc'S- • f�l to -y -ll City of Tukwila — Public Works Maintenance Department 600 Minkler Blvd, Tukwila, WA 98188 Backflow Assembly Test Report Form OigeSa PA 0 NAME Outback Steakhouse SERVICE ADDRESS 16510 Southcenter Pkwv CITY auhaila ACCOUNT # Q8_0212 METER # 42031656 STATE WA ASSEMBLY LOCATION UAr lei hgmsher CROSS- CONNECTION CONTROL FOR? internal Plumbina Sva em SIZE 0.75" _ MAKE Wi1ki}� LINE PRESSURE AT TIME OF TEST? ZIP CODE 98188.3305 MODEL 975XL „___ _ TYPE RPBA SN Can't Re-ad PSI NEW? ❑ EXISTING? - 11PLACEMENT? ❑ INITIAL TEST RESULTS TESTS AFTER REPAIR OR CLEANING 1 RPBA PSI DROP ACROSS #1 CHECK VALVE PSID PSID ❑ ❑ ❑ ❑ PSI DROP ACROSS #1 CHECK VALVE CI, 0 PSID RELIEF VALVE OPENED RELIEF VALVE OPENED o) • 6 PSID #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? 112 CHECK VALVE LEAKED? APPROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes ❑ No #1 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? - #2 CHECK VALVE CLOSED TIGHT? #2 CHECK VALVE LEAKED? PROVED AIR GAP PROVIDED? RPBA PASSED TEST? Yes El ;V) ❑ 0 P4 No ❑ DCVA #1 CHECK VALVE CLOSED TIGHT? PSID PSID ❑ #1 CHECK VALVE CLOSED TIGHT? PSID #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? #1 CHECK VALVE LEAKED? #2 CHECK VALVE CLOSED TIGHT? 0 PSID #2 CHECK VALVE LEAKED? DCVA PASSED TEST? Yes No #2 CHECK VALVE LEAKED? DCVA PASSED TEST? Yes 0 No ❑ PVBA AIR INLET OPENED AT PSID ❑ PSID ❑ AIR INLET OPENED AT PSID AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT AIR INLET FAILED TO OPEN? CHECK VALVE HELD TIGHT AT 0 PSID CHECK VALVE LEAKED? PVBA PASSED TEST? Yes No CHECK VALVE LEAKED? PVBA PASSED TEST? Yes ❑ No 0 APPROVED ASSEMBLY? REMARKS PROPER INSTALLATION? El INSPECTED BY CCS? 0 �0.ay�5 PHONE 1125 Z77 Z.8 t _ MODEL SN NOS tWo 3 CALIBRATION DATE 2,2-- /1 - 290 -490 approve Test Methods and Differential Pressure Test Equipment r+ __ 3U n CERTIFICATION # 8-5 2dLs DATE TESTED /o — y -4/ REPAIR DATE I TEST COMPANY II TEST KIT MAKE R ld d,1 {! S T 1 certify that I used WAC 24 TESTER'S NAME (PRINTED) SIGNATURE REPAIRED BY RETESTED BY CERT # DATE TESTED 01 eir cAA/4' 'A/ 4•3 °°X' PERMANENT FILE COPY D �Z - D05' • a Joanna Spencer From: Todd Reedy Sent: Thursday, January 05, 2012 8:13 AM To: Joanna Spencer Subject: RE: Outback Steakhouse @16510 SC Pkwy D12 -005 Happy new year Joanna, Backflow preventer status at Outback Steakhouse: -No RPPA on 1.5" domestic service for premise isolation. - 4" fire DCDA is current. - They have a separate 1" irrigation service connection with a DCVA that is current. -FDC OK. -AMR OK. - Internally they have a 0.75" RPPA for a dishwasher that failed the annual test last October. The tester said it will be repaired and retested, however we have not yet received a test report. Let me know if you need anything else from us, Todd From: Joanna Spencer Sent: Wednesday, January 04, 2012 4:25 PM To: Todd Reedy Cc: Han Kirkland Subject: Outback Steakhouse @16510 SC Pkwy D12 -005 Todd - Are they current on their backflows ? Thanks. Joanna Spencer Development Engineer Tukwila Public Works 6300 Southcenter Blvd., Suite 100 Phone: (206)431 -2440 Fax: (206)431 -3665 Joanna.Spencer@ TukwilaWa.gov /www.TukwilaWa.gov 1 PERMANENT FILE COPY t:z 005 •PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -005 PROJECT NAME: OUTBACK STEAKHOUSE DATE: 02/24/12 SITE ADDRESS: 16510 SOUTHCENTER PY Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works 1�� Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 01/26/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 02/23/12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 ERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -005 PROJECT NAME: OUTBACK STEAKHOUSE DATE: 01/04/12 SITE ADDRESS: 16510 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: B I ding Division Pullin c Wo ks\ �1 19).1'L 01. 12 Fire Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete. Incomplete DUE DATE: 01/05/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 02/02/12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 041-- Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials:�1a/V`' Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us •1.:::1.4 »K.FrtTT' •'',: .. .. a -i"•g1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 0124 \12- Plan Check/Permit Number: D 12-005 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Outback Steakhouse Project Address: Contact Person: Summary of Revision: 16510 Southcenter Py Mi �q &\ C49 Phone Number: L-Zc i`'"l1 7,M woAcc ?ofivIA sdsokt4eA reTAA,(tbk. Set ry vvii+ P w 12-- ©1,S Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ollul Il�z \applications \forms - applications on Ime\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople liter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name KIRTLEY -COLE ASSOCIATES LLC UBI No. 602442850 Phone 4256090400 Status Active Address 1010 Se Everett Mall Way, Ste License No. KIRTLAL951BC Suite /Apt. License Type Construction Contractor City Everett Effective Date 1/3/2005 State WA Expiration Date 1/3/2013 Zip 98208 Suspend Date County Snohomish Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status KIRTLCP044LK KIRTLEY COLE PETROLEUM INC Construction Contractor General Unused 6/12/1996 7/1/2004 Archived LAKEVHL966PE LAKEVIEW HOMES LLC Construction Contractor General Unused 10/5/2004 10/5/2006 Expired KIRTLCA272RF KIRTLEY COLE ASSOCIATES INC Construction Contractor General Unused 12/6/1973 7/1/2005 Re Re- Licensed Business Owner Information Name Role Effective Date Expiration Date LEWINSKI, MARK W Partner /Member 01/01/2009 Amount KIRTLEY, RALPH R Partner /Member 01/03/2005 01/01/2009 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS & SURETY CO 104408303 12/30/2004 Until Cancelled $12,000.00 01/03/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 NATIONAL FIRE INSURANCE COMPAN 4024636774 07/01/2010 07/01/2012 $1,000,000.00 06/29/2011 4 ZURICH AMERICAN INS CO CP0399269405 07/01/2008 07/01/2010 $1,000,000.00 06/24/2009 3 ZURICH AMERICAN INS CO CP0399269403 07/01/2007 07/01/2009 $1,000,000.00 06/25/2008 2 ZURICH AMERICAN INS CO CP0399269402 07/01/2005 07/01/2007 $1,000,000.0006 /26/2006 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 10 -2- 03991 -9 SNOHOMISH Date: 07/08/2010 https://fortress.wa.gov/lni/bbip/Print.aspx Date: Dismissed Date: 01/26/2012 GENERAL NOTES A. RECESSED GENERAL DOWN LIGHTING TO REMAIN UNLESS NOTED OTHERWISE. B. ALL PURPLE LAY —IN CEILING TILE, INCLUDING TAKE AWAY ROOM AND KITCHEN ENTRIES, ARE TO BE DEMOLISHED AND REPLACED WITH NEW LAY —IN TILE (G —I). G.C. TO PAINT EXISTING GRID, AIR SUPPLIES AND RETURNS (P -3). SEE SHEET A5.3 FOR FINISH SCHEDULE. G. S.C. TO REMOVE ALL TABLE TOP EXTENSIONS FROM EXISTING TO REMAIN LOW WALLS AND REPAIR/RE— FINISH LOW WALLS TO LIKE NEW CONDITION. D. 6.G. TO REMOVE ALL EXISTING WINDOW AND DOOR DECALS, EXCEPT FOR STREET ADDRESS. E. ALL EXISTING TRACK AND TRACK HEADS TO BE DEMOLISHED. F. ALL DEMOLITION KEY NOTES MAY NOT APPLY. G.G. TO REMOVE ALL MISCELLANEOUS WALL MOUNTED SIGNAGE, SUCH AS BUT NOT LIMITED TO, HEALTH DEPARTMENT PERMIT AND CERTIFICATE OF OCCUPANCY TO ALL FOR INSTALLATION OF NEW REMODEL ELEMENTS. G.G. TO MOUNT/DISPLAY RELOCATED SISNAAE IN AN APPROVED LOCATION AS PERMITTED BY LOCAL CODES AND ORDINANCES. COORDINATE WITH MANAGING PARTNER. H. G.G. TO REMOVE ALL WALL MOUNTED ACCESSORIES (MENU HOLDERS, ETC.) FROM CUSTOMER WAITING AREA UNLESS NOTED OTHERWISE. OT -: EXISTI \G LIGHT FIXTURE COU \T = 176 EXISTI \G TO BE REVOVED = 69 VAX THIS REPRESE \TS LESS THA\ 60% OF FIXTURES. 44" EXISTI \G EGRESS PATH, CHA \GES. SHEET INDEX D1.1 A2.1 A3.1 A4.1 A5.1 A5.2 A5.3 A5.4 E1.0 E3.0 DEMOLITION FLOOR PLAN AND NOTES FLOOR PLAN AND NONTES FINISH FLOOR PLAN AND NOTES LIGHTING / CEILING PLAN AND NOTES INTERIOR ELEVATIONS AND NOTES INTERIOR ELEVATIONS AND NOTES INTERIOR ELEVATIONS AND NOTES RESTROOM PLAN, NOTES, AND WALL DETAIL ELECTRICAL NOTES, SCHEDULES & LEGENDS LIGHTING PLAN & LIGHT SUMMARY FORM \0 r rim SEP P7 E PERMIT REO FOR: e7iftchanIcal ereectrical erPlumting Inas Ming City of Tukwila BUiLDINO DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t l ITS:: ;cvAsions will require a new plan submittal and may include additional plan review fees. • j FILE COPY Permit N©.. b 1 00 fol. r r 4 e w a p p a l is a b j e c t to elms does not omissions. ns. r. ..�� of Ji�on documents YWs not �orz 1,i , ., ,oi iii any add code or ordnance. Rweipt of LiQraftec E is i} ' cotillions is ackn iy By Data: d zo City Of Tukwila BUILDING DIVISION Iiiei��A• ills DRY STORAGE 1 1 1 dui- 1ZJI won KEY NOTES I DEMO WALL WASH FIXTURES THROUGHOUT 2 DEMO CEILING TILES, LIGHTING, HVAG DIFFUSERS, ETC. TO PREPARE FOR NEW GINS CEILING, INSTALL AT BAR DEMO FALSE WOOD COLUMNS, REMOVE WOOD SURROUND PROM STRUGT COLUMNS, AND REPAIR GAP FINISH 4 DEMO CANTILEVERED LIGHT AND REPAIR EXISTING COLUMN 5 DEMO PENDANT FIXTURES. J —BOX 4 WIRING, TO REMAIN WHERE BEING RE —USED. COORDINATE WITH OSI PM 6 1a DEMO WOOD DOORS AND H.M. FRAME. PROVIDE NEW PER GI ICCT A2.I, COORDINATE WITH 051 PM 7 DEMO METAL WALL PANELS s DEMO BASEBOARDS IN PREPARATION TO INSTALL VINYL FLOOR AND WALL VENEER a DEMO BACK BAR CABINET AND TV SHELVES 10 DEMO HOSTESS PODIUM II RELOCATE EXISTING 61—ASS STORAGE CABINETS. REFER TO SHEET A2.I 12 DEMO OF TOP GAP AND ALL. WOOD TRIM FROM LOW WALL IN PREPARATION FOR LOW WALL ADDITION. COORDINATE WITH DETAIL I /A5.1 AND SHOP DRAWINGS. 15 RELOCATE FLAT PANEL T.V. AND ASSOCIATED ELECTRICAL. REF=ER TO SHEET A3.I 14 RELOCATE EXISTING ELECTRICAL FEEDS TO NEW HOSTESS AREA SHOWN ON C.HCCT F5—I. COORDINATE WITH 091 PM 15 DEMO CUSTOMER WAITING. BENCHES 16 DEMO WOOD FLOOR AS SHOWN<AND PREPARE SUBSTRATE TO RECEIVE NEW VINYL. FLOOR. SEE SHEET A3.I 17 DEMO QUARRY TILE AND PREPARE SUBSTRATE TO RECEIVE NEW VINYL FLOOR. SEE SHEET A3.I Is DEMO APRON TRIM AND BASEBOARDS IN PREPARATION OF NEW VINYL FLOOR AND WALL VENEER Ia DEMO CEILING FANS AND ASSOCIATED ELECTRICAL BACK TO SOURCE 20 DEMO TABLE TOP, RETAIN TABLE BASES AND CHAIRS 21 NOT IN USE 22 DEMO TV, TV MOUNT, AND ASSOCIATED ELECTRICAL 23 DEMO TRANSITION. REFER TO SHEET FLR -I FOR NEW TRANSITION PLACEMENT 24 NOT IN USE 25 EXISTING 50" T.V. TO BE REMOVED AND REPLACED AFTER NEW DECOR 15 INSTALLED 26 DEMO CERAMIC TILE AND PREPARE SUBSTRATE TO RECEIVE NEW VINYL FLOOR. SEE SHEET A5.I 21 REMOVE EXISTING FLOOR TILE AND BASE. PREP CONCRETE SLAB FOR NEW TILE. 2S NOT IN USE 20i DEMO MENU HOLDER 30 DEMO PORTION OF SLOPED TOP GAP BEHIND NEW WALL MOUNTED LOUVER CABINETS ONLY. REFER TO SHEET A2.1 31 NOT IN USE 32 NOT IN USE 200 RELOCATE EXISTING FIRE EXTINGUISHER PER FIRE MARSHAL 201 NOT IN USE 202 DEMO MILLWORK 203 NOT IN USE 204 RELOCATE EXISTING HONEYWELL SENSOR OT -: EXISTI \G LIGHT FIXTURE COU \T = 176 EXISTI \G TO BE REVOVED = 69 VAX THIS REPRESE \TS LESS THA\ 60% OF FIXTURES. 44" EXISTI \G EGRESS PATH, CHA \GES. SHEET INDEX D1.1 A2.1 A3.1 A4.1 A5.1 A5.2 A5.3 A5.4 E1.0 E3.0 DEMOLITION FLOOR PLAN AND NOTES FLOOR PLAN AND NONTES FINISH FLOOR PLAN AND NOTES LIGHTING / CEILING PLAN AND NOTES INTERIOR ELEVATIONS AND NOTES INTERIOR ELEVATIONS AND NOTES INTERIOR ELEVATIONS AND NOTES RESTROOM PLAN, NOTES, AND WALL DETAIL ELECTRICAL NOTES, SCHEDULES & LEGENDS LIGHTING PLAN & LIGHT SUMMARY FORM \0 r rim SEP P7 E PERMIT REO FOR: e7iftchanIcal ereectrical erPlumting Inas Ming City of Tukwila BUiLDINO DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. t l ITS:: ;cvAsions will require a new plan submittal and may include additional plan review fees. • j FILE COPY Permit N©.. b 1 00 fol. r r 4 e w a p p a l is a b j e c t to elms does not omissions. ns. r. ..�� of Ji�on documents YWs not �orz 1,i , ., ,oi iii any add code or ordnance. Rweipt of LiQraftec E is i} ' cotillions is ackn iy By Data: d zo City Of Tukwila BUILDING DIVISION Iiiei��A• ills DRY STORAGE 1 1 1 dui- 1ZJI won 0 J • 0 *, 1 itb- ® i 1 1a 1a % a 0 0 /IV �� 0 \ ( _ . / /Z�y IZI I ®I El Mt IN I0 T ,1 T T T F /A5.2 T '4 ��i�� CD --- I I `I_ — ,� 0 - ----, 12 15 0 J • 0 *, / mom NIP 0 MI ""Kiii(A/fir Jill,t1 Lo OFFICE MECHANICAL u . 0 0 r Oz, 0 1 4 17,74.-Az,97-///, PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD $pproved yl Z [i Date: 31 DEMOLITION FLOOR PLAN SCALE: 3,. = +. —o. O r J L_ UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.31P7 f.425.747.7149 www.mlarch.com stamp consultant REVIEWED FOR CODE COMPLIANCE APPROVED JAN 262012 it -3 City ofTukwila BUILDING DIVISION project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title DEMOLITION FLOOR PLAN RECEIVED JAN 05 Zu1Z TUKWILA PUBLIC WORKS cirtijiOrlaun JAN A 4 2012 PERMIT CENTER drawn by MSC checked by issued date description V\2OO c; D1.1 ® IZI iw 1®1 Mt I0 T ,1 , T 11 ,, � [J ,1 All F /A5.2 T '4 --- I I `I_ — ,� 0 - ----, 12 15 / mom NIP 0 MI ""Kiii(A/fir Jill,t1 Lo OFFICE MECHANICAL u . 0 0 r Oz, 0 1 4 17,74.-Az,97-///, PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD $pproved yl Z [i Date: 31 DEMOLITION FLOOR PLAN SCALE: 3,. = +. —o. O r J L_ UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.31P7 f.425.747.7149 www.mlarch.com stamp consultant REVIEWED FOR CODE COMPLIANCE APPROVED JAN 262012 it -3 City ofTukwila BUILDING DIVISION project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title DEMOLITION FLOOR PLAN RECEIVED JAN 05 Zu1Z TUKWILA PUBLIC WORKS cirtijiOrlaun JAN A 4 2012 PERMIT CENTER drawn by MSC checked by issued date description V\2OO c; D1.1 LD] REMODEL EQUIPMENT SCHEDULE OQTY DESCRIPTION COMMENTS EXISTIN& HEADER 2 EXISTING SOFFIT TO REMAIN E509 8 I LOT DININ6 CHAIR EXISTIN6 TO BE RE- USED/NEIN CUSHIONS g O CLASSIC TABLE TOP EXISTING TO BE RE- USED/RE- LOCATED 10 0 TABLE BASE EXISTIN6 TO BE RE- USED/RE- LOCATED II 0 TABLE BASE - CANTILEVER EXISTIN6 TO BE RE- USED/RE- LOCATED 13 O BOOTH SEATIN6 EXISTING TO BE RE- USW/RE- LOCATED 15 I LOT BAR STOOL EXISTING TO BE RE- USED/NEW CUSHIONS 16 1 SILVERWARE/SKEYEPAD HOLDER EXISTING TO BE RE- USED/RE- LOCATED 228 I &LASS STORAGE CABINET EXISTING TO BE RE- USED/RE- LOCATED 24 1 THREE DOOR REFRIGERATOR EXISTIN6 TO BE RE -USED 84 2 32" VIZIO (HDTVIOA) FLAT PANEL EXISTING TO BE RE- USED/RE- LOCATED 134A 0 WALL MOUNTED TV BRACKET EXISTING TO SE RE- USED/RE- LOCATED 848 0 GEILIN6 MOUNTED TV BRACKET EXISTING TO EE RE- USED/RE- LOCATED S46 0 [VERIFY SIZE LARGER THAN 32 "1 (BRAND) FLAT PANEL EXISTING TO SE RE- USED/RE- LOCATED ISO 1 EXISTING 50" BACK BAR T.V. EXISTIN6 TO BE RE -USED 504 2 MENU HOLDER MILLWORK CONTRACTOR 504A I SIGN: HOURS OF OPERATION DECOR CONTRACTOR 5045 I SIGN: BLOKES (MEN'S) RESTROOM DECOR CONTRACTOR 504G 1 SIGN: SHEILAS (WOMEN'S) RESTROOM DECOR CONTRACTOR 504D 1 SIGN: MAXIMUM OCCUPANCY DECOR CONTRACTOR 504E 1 SI6N: HAVE A DRINK ON US DECOR CONTRACTOR 504E • 1 SIGN: RING BELL FOR CERTIFICATES DECOR CONTRACTOR 5046 1 SIGN: ADA SI6N WITH BRAILLE - MEN'S RESTROOM DECOR CONTRACTOR 50414 I SIGN: ADA SIGN WITH BRAILLE - WOMEN'S RESTROOM DECOR CONTRACTOR 5041 1 SIGN: PROPRIETOR - VINYL DECAL (10 I/2 "x91 ") DECAL CONTRACTOR 504.1 0 SIGN: PROPRIETOR - STANDARD SIZE DECOR CONTRACTOR 504K 0 SIGN: PROPRIETOR - SMALLER SIZE DECOR CONTRACTOR 506 2 WAITIN6 AREA BENCH - MID BACK FURNITURE CONTRACTOR 506A 1 WAITING AREA BENCH - HIGH BACK FURNITURE CONTRACTOR 5068 4 COCKTAIL TABLE FURNITURE CONTRACTOR 506D 2 OTTOMAN FURNITURE CONTRACTOR 506E O CUSTOMER WAITING CHAIR FURNITURE CONTRACTOR 509 I HOST STAND MILLWORK CONTRACTOR 5O9A I HOST CABINET MILLWORK CONTRACTOR 5015 1 HAVE A DRINK ON US CABINET 4 STAND MILLWORK CONTRACTOR 509C 1 UMBRELLA STAND MILLWORK CONTRACTOR 50917 1 HOST STAND - METAL DECOR CONTRACTOR 509E . 33 WAITNESTISULE WALL PANELING MILLWORK CONTRACTOR 509P 94 WAITNESTIEULE BATTEN STRIP MILLWORK CONTRACTOR 508 O DINING CHAIR CHAIR CONTRACTOR 506A I LOT CHAIR CUSHION CUSHION CONTRACTOR 50g15 3 CLASSIC TABLE TOP FURNITURE CONTRACTOR 506H 0 CLASSIC TABLE TOP W/ FLIP -UPS FURNITURE CONTRACTOR 510 0 TABLE BASE FURNITURE CONTRACTOR 511 3 TABLE BASE - CANTILEVERED FURNITURE CONTRACTOR 515 O BOOTH SEATING MILLWORK CONTRACTOR 513A 0 BOOTH END PANEL. MILLWORK CONTRACTOR 5138 0 FINISHED BACK MILLWORK CONTRACTOR 5I3C I LOT BOOTH CUSHION MILLWORK CONTRACTOR 515 O BAR STOOL. CHAIR CONTRACTOR 5I5A I LOT BAR STOOL. CUSHION CUSHION CONTRACTOR 516 1 SKEYEPAD /SILVERWARE HOLDER MILLWORK CONTRACTOR 511 I VESTIBULE PAGER HOLDER MILLWORK CONTRACTOR 51411 20 SPICE JARS - FILLED DECOR CONTRACTOR TO ASSEMBLE 520 I SET FRESH WALL DISPLAY CABINETS DECOR CONTRACTOR 52OA 1 HOST TV CABINET DECOR CONTRACTOR 5208 2 WALL DIVIDER: 6' -2" (1 CUTOUT METAL PANEL) DECOR CONTRACTOR 5206 2 WALL DIVIDER: 4' -2" DECOR CONTRACTOR 520D 2 WALL DIVIDER: 6' -2" (2 CUTOUT METAL PANELS) DECOR CONTRACTOR 520E O WALL DIVIDER: 5' -6" (2 CUTOUT METAL PANELS) DECOR CONTRACTOR 520P 0 WALL DIVIDER: 51-6" (I CUTOUT METAL PANEL) DECOR GONTRAGTOR 5206 0 WALL DIVIDER: 6' -2 "x15" HIGH (I CUTOUT METAL PANEL) DECOR CONTRACTOR 520H O WALL DIVIDER: 4' -2 "x15" HIGH DECOR CONTRACTOR 5201 0 WALL DIVIDER: 6' -2 "x15" HIGH (2 CUTOUT METAL PANELS) DECOR CONTRACTOR 520J 0 OPEN OPEN 52OK O WALL. DIVIDER: 8' -0" DECOR CONTRACTOR 52OL O OPEN OPEN 52OM 0 WALL DIVIDER ASSEMBLY: II' -II" DECOR CONTRACTOR 520N 0 WALL DIVIDER ASSEMBLY: 19' -4 1/2" DECOR CONTRACTOR 520P 2 P.O.S. WALL DIVIDER DECOR CONTRACTOR 521 O BAR TOP MILLWORK CONTRACTOR 52IA o BAR DYE PANELS MILLWORK CONTRACTOR 522 I BACK BAR TOP MILLWORK CONTRACTOR 522A 2 UNDER BAR &LASS STORAGE CABINET MILLWORK CONTRACTOR 522E O &LASS STORAGE CABINET MILLWORK CONTRACTOR 522C 0 BAR FOOT RAIL AND BRACKETS MILLWORK CONTRACTOR 525A I GLASS ICE DISPLAY - IS" X 24" 6LA5TENDER 53-1 O BEER TROU614 BEER VENDOR 542 I WOOD STACK WALL ASSEMBLY: 1'48 1/2" MILLWORK CONTRACTOR 542A 1 WOOD STACK WALL ASSEMBLY: 6' -4 1/2" MILLWORK CONTRACTOR 5425 I WOOD STACK WALL INSTALL KIT MILLWORK CONTRACTOR 542E O WOOD STACK WALL - CUSTOM SIZE MILLWORK CONTRACTOR 548 I SET BACK BAR CABINETS MILLWORK CONTRACTOR 548,4 0 LOWERED CABINET MILLWORK CONTRACTOR 5488 0 LOUVERED CABINET MURAL DECOR CONTRACTOR 5486 I SET BAR GEILIN6 GUT -OUT PANELS DECOR CONTRACTOR 548P I BAR SOFFIT ASSEMBLY MILLWORK CONTRACTOR 548E 2 WALL MOUNTED LOUVER CABINET MILLWORK CONTRACTOR 548E 2 WALL MOUNTED LOUVER CABINET MURAL DECOR CONTRACTOR 54Q . I 40" LGD TV MOUNTED INSIDE HOST CABINET TV CONTRACTOR 54gA 1 32-40" HOSTESS C.A. B FLUSH MTD. T.V. BRGKT. TV CONTRACTOR 54413 I TV CONTRACTOR HDMI GABLE FOR HOSTESS VIDEO 54gG I VIDEO DELIVERY SYSTEM TV CONTRACTOR 5SOA O GEILIN6 CHANDELIER DECOR CONTRACTOR 5505 1 GEILIN6 CHANDELIER DECOR CONTRACTOR 5506 I GEILIN6 CHANDELIER DECOR CONTRACTOR 584 2 TV: 32" HDTV AT BAR 4 CUSTOMER WAITING TV CONTRACTOR 554A 3 TV: 32" ARTICULATING ARM WALL MOUNTED BRACKET TV CONTRACTOR 5845 1 TV: 32" CEILING MOUNTED BRACKET TV CONTRACTOR 5846 0 TV: 36 "/39''/40" 1V MOUNT ADAPTER PLATE TV CONTRACTOR 5a0 0 PARTY TABLE BASE MILLWORK CONTRACTOR 5180 0 TV: 55" HDTV AT BACK BAR SEE NUMBER ISO ABOVE SISOA 1 TV: 46" TO 55" FLUSH MOUNTED BRACKET TV CONTRACTOR 518013 0 TV: 46" HDTV AT BACK BAR TV CONTRACTOR GENERAL ELECTRICAL NOTES A. ELECTRICAL CONTRACTOR TO RELOCATE MUSIC CONTROLS TO NEW SPECIFIED LOCATION SHOWN ON SHEET A2.I. COORDINATE WITH LOCATION OF DIMMER PANEL. B. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL. GAT -5 GABLE. TERMINATION BY 051 I.T. ELECTRIC KEY NOTES C ) EXISTIN& HEADER 2 EXISTING SOFFIT TO REMAIN E509 115 V, I PHASE, 20 AMP QUAD RECEPTACLE 0 32" AFF 4 12" FROM ADJACENT WALL TO CENTER OF RECEPTACLE E509A 115 V, I PHASE, 20 AMP DUPLEX RECEPTACLE . THRU SLAB (FLUSH MOUNTED) E50-? J BOX 0 26" AFF 4 12" FROM ADJACENT WALL TO CENTER OF BOX E509G DRILL 1 1/4" DIAMETER HOLE THRU LOW WALL 0 32" APF 4 IS" FROM ADJACENT WALL FOR HDMI GABLE E5O1D FLUSH MOUNTED J BOX THRU SLAB WITH. 3/4" CONDUIT AND PULL STRING ROUTED FROM BOX, THRU 5TAGK WALL CHASE, AND 6" ABOVE LAY -IN GEILIN6 FOR GAT-5 GABLE. GABLE TO BE RUN TO MANAGERS OFFICE WITH 10' WHIP. FINAL CONNECTION BY OSI I.T. E509E PHONE JACK 0 26" AFP 4 IS" FROM ADJACENT WALL TO CENTER OF OUTLET E509P PHONE JACK TO BE PROVIDED AT HOST STAND E541A 115 V, I PHASE, DEDICATED CIRCUIT QUAD WITH ISOLATED &ROUND THRU LOW WALL FOR POS. MOUNT TIGHT TO BOTTOM GAP IN APRON TRIM E54115 J BOX FOR GAT -5 GABLE TO POS. MOUNT TIGHT TO BOTTOM OF GAP IN APRON TRIM E58413 115 V, I PHASE DUPLEX RECEPTACLE MOUNTED IN GEILIN6 FOR N. RELOCATE EXISTING PER PLAN E584D 4x4 J BOX WITH 2" CONDUIT MOUNTED IN GEILIN6 FOR HDTV GABLE. RELOCATE EXISTING PER PLAN E584D 115 V, I PHASE DUPLEX RECEPTACLE MOUNTED 0 9' -6" A. KEEP TIGHT TO TV MOUNTING BRACKET E584E 4x4 J BOX WITH 2" CONDUIT MOUNTED 0 1'-6" AFF. KEEP TIGHT TO DUPLEX E58417 E5ISO 115 V, I PHASE, 20 AMP QUAD RECEPTACLE ® 9' -6" APF FOR TV (OR REUSE EXISTING) E5I8I 4x4 J BOX WITH 2" CONDUIT ® 1'-6" FOR HDTV GABLE. (OR REUSE EXISTING) E5182 115 V, 1 PHASE, 20 AMP QUAD RECEPTACLE ® 6'-4" AFF FOR TV GABLE BOX E5183 HDTV GABLE THRU WALL MOUNTED 0 6'-4" A. KEEP TIGHT TO QUAD E5182 20 NOT USED ELECTRICAL LEGEND 6.C. TO PROVIDE NEW SMOOTH DRYWALL FINISH. DUPLEX RECEPTACLE - 120 V, 20 AMP, GFGI - HORIZONTAL MOUNT (TYPICAL) 6.G. TO PROVIDE BLACK FRP FROM NEW BACK BAR COUNTER TOP TO TOP OF FLOOR BASE INSIDE BAR AREA QUAD RECEPTACLE OJ JUNCTION BOX 0 HDMI HOLE. SEE ELECTRIC NOTE E509G 0 PHONE JACK GENERAL NOTES A. GENERAL CONTRACTOR TO COORDINATE WITH 051 CONSTRUCTION MANAGER FOR ALL CRITICAL CONSTRUCTION DATES PERTAINING TO THE PROJECT. B. 6.C. TO COORDINATE WITH OSI EQUIPMENT PROJECT MANAGERS FOR DELIVERY AND I INSTALLATION OF ALL NEW MILLWORK ITEMS. MILLWORK ITEMS TO BE FURNISHED BY MILLWORK CONTRACTOR AND INSTALLED BY 6.C. G. 6.G. TO COMMUNICATE WITH STORE MANA6IN6 1°ARTNER RE6ARDIN6 CONSTRUCTION SCHEDULE TIMELINE AND SUB - CONTRACTOR SCHEDULE FOR 6AININ& ACCESS TO THE RESTAURANT. D. 6.G. TO VERIFY DIMENSIONS IN AREAS OF NEW CONSTRUCTION PRIOR TO STARTING WORK. ANY DISCREPANCIES ARE TO BE COMMUNICATED TO OSI DESIGN DEPARTMENT FOR CORRECTION PRIOR TO START OF CONSTRUCTION. E. REFER TO SHEET A4.I FOR LIGHTING SPECIFICATIONS, MOUNTING HEIGHT, AND LOCATION. F. REFER TO SHEET A5.3 FOR INTERIOR ELEVATIONS AND FINISH SCHEDULE. 6. REFER TO SHEET A3.1 FOR FLOOR FINISH PLAN AND FLOOR FINISH SCHEDULE. H. ALL EQUIPMENT NOT LABELED IN CONSTRUCTION DOCUMENTS ARE TO REMAIN AS EXISTING. I. &.C. TO REFER TO WALL PANELING PLAN ON SHEET A5.2 FOR WAITING AREA WAINSCOT. J. IF ENTRY VESTIBULE HAS A WALL HEATER, 6.C. IS TO PAINT THE HEATER BLACK OR REPLACE WITH BLACK COVER. r 0 KEY NOTES I EXISTIN& HEADER 2 EXISTING SOFFIT TO REMAIN 3 NEW 36" SINGLE -LITE WOOD DOOR WITH DECORATIVE SLAW. FINISH: STAIN (5-5) 4 SET FAUX COLUMN SPACING TO MATCH EXISTING FAUX COLUMN SPACING ON OPPOSITE SIDE OP BAR 5 EXISTING PLATFORM 6 EXISTING FALSE COLUMN TO BE RELOCATED. 6.0. TO REPAIR EXISTING TOP GAP 9 NOT USED 8 6.G. TO REPLACE EXISTING TOP GAP AND APRON TRIM WITH NEW OAK GAP AND APRON TRIM. FINISH: STAIN (S-I) q NEW LOCATION FOR ALL FRONT OP HOUSE MUSIC CONTROLS. SEE 6ENERAL ELECTRICAL NOTE 'A' 10 EXISTING DIMMER PANEL II NOT USED 12 REFER TO 6/A5.I FOR LOCATION OF EQUIPMENT FOR ITEMS 520 4 52OA 13 6.C. TO INSTALL I /4" GYPSUM BOARD OVER EXISTING PLYWOOD AND STUCCO FINISH TO MATCH ADJACENT WALLS 14 6.G. TO REFINISH EXISTING METAL PANELS. FINISH: PAINT (P -12) 15 6.G. TO REFINISH RESTROOM DOORS. FINISH: STAIN (S-4) 16 REFER TO SHEET A5.3 FOR ACCESSIBLE 5ISNA6E LOCATIONS Ii 6.C. TO ADD TO LENGTH OF LOW WALL AS NECESSARY TO MEET MINIMUM WALL DIMENSION IS 6.C. TO PROVIDE WASTE LINE FROM BACK SIDE OF ICE BIN TO FLOOR DRAIN. REFER TO I/A5.2 la NEW 36" SINGLE -LITE WOOD DOOR WITH CLEAR &LASS. FINISH: STAIN (S-5) 20 NOT USED 21 6.C. TO PROVIDE NEW SMOOTH DRYWALL FINISH. 22 6.G. TO PROVIDE BLACK FRP FROM NEW BACK BAR COUNTER TOP TO TOP OF FLOOR BASE INSIDE BAR AREA 23 2'- O "XI' -4" SHELF MOUNTED AT 6' -4" AFF TOP OP SHELF BY 6.G. 24 6.C. TO PAINT ALL WALLS IN TAKE -AWAY (P -12) 200 PAINT STUCCO WALLS IN KITCHEN ENTRANCES, COLOR P -12 WALL LEGEND EXISTIN6 FULL HEIGHT WALL EXISTIN6 LOW WALL (54" Ate) It7-* : ∎Z∎ ∎' ∎' ∎' ∎ZiegtZt'taZ EXISTING LOW WALL (50" AFF) f. /" / / / / //Z Z. A WOODSTAGK WALL lJ- ����������A NEW LOW WALL (54" AFF) TO MATCH EXISTING 6'4 112" (STACKWALL) HOSTESS AREA PLAN ""D\ 00i SECURED STORAGE DRY STORAGE 1 °I • • MEN5 R ESSLTR OM :1 OFFICE +8' NEW RESTROOM GEILIN6 FRAMING: - 2x6 LEDGER - 2x6 ® 24 "o.c. -LU26 HANGER (SIMPSON OR E0) -(1) ONE LAYER B" GWB - PAINT O DISHWASHER 1. KITCHEN MECHANICAL OM 1 ELE�INGI AL E5183 rlig E5182 0 IT 1 E518 E5181 iS 548E. 548F N 270 136 _- 1- .!rrriri� 520P DINING AREA Tag +q'-o" GEILIN6 5'- ■ I2' -2" 0 • u +8' -0" CEILING (SOFFIT) 0 i� ABOVE 4���ri - - - - - -- rrr.�rri i 74. 2' -1 I: 24) 180 (22 ISOA 6' -5" Q +IO' -0" CEILING ® BAR +q' -0" GEILIN6 1- "iii► 4-0" GEILIN6 A52 - J E'...n.....— S.---..0 +q' -0" GEILIN6 0 30X28 0 -. NA SS � AM ., ! E541A E541B - 30X28 0 0 4' -0" w ►L 5' -0" ILA 0 e Ca E507F 1 MI E584B O ' ®, CUSTOMER WAITING rrra r e.r rrrrrr. rrss1 • ►: ►, 43 SIN E584D ►i 30X28 NIP 0 0 44 NEW 30 "x38" FREESTYLE COCA COLA MACHINE w/ CABINET FOR ICE -TEA AND WATER .A Tay no • w 0 +q'-o" GEILIN6 DINING AREA in m Ark low 0 ABOVE +8' -0" CEILING (SOFFIT) O 5' -0 A:: L 2 PIM! INEEN MEM ® ♦r 1 1 1 1 7'-O +8' -0 CEILING 11 11 1IN■ T I NARROW ART BETWEEN WINDOWS, THIS AREA NOTE: G.C. TO VERIFY BOOTH CUSHION DIMENSIONS ARE THAT OF THE SEAT WIDTH BETWEEN THE END PANELS. FLOOR PLAN SCALE: i" = 1' -0" 4© ro • 1� UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA,.WA 98188 ... set drawing title FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 6 2012 City ofTukwila BUILDING DIVISION ECEIV�p CITYROFTUK�WLA JAN 0.4 2012 PERMIT CENTER drawn by MSC checked by A 8.18.2011 Corp changes issued date description A2.1 r Q KEY NOTES SPECIFICATION MANUPACTURER I EXISTING QUARRY TILE FLOOR TO REMAIN 2 EXISTING WOOD FLOOR TO REMAIN 3 EXISTING CERAMIC TILE FLOOR TO REMAIN 4 SPRAYGRETE COATING BY OWNER 5 NEW BLACK MARBLE TRANSITION STRIP (2" WIDE MAXIMUM X 1/2" HIGH MAXIMUM) MANNINGTON NEW VINYL. ACCENT FLOOR AND 3" BORDER (PV-4) — LAY FLOORING AT 45 DEGREES INSIDE BORDER 1 EXISTING TRANSITION STRIP 8 NEW VINYL FLOOR (FV-5) THROUGHOUT a NEW VINYL FLOOR (PV— I) WITH 3" WIDE BORDER (FV-4) 10 EXISTING THRESHOLD II TRANSITION DIRECTION IN FLOOR HERE MENS RESTROOM FLOOR FINISH SCHEDULE FINISH SPECIFICATION MANUPACTURER CONTACT F —I WOOD FLOOR PATCH — ENGINIMRED WOOD FLOOR. COLOR: GINGER ARMSTRONG PREMIER PERFORMANCE SHANNON FALCONE PHONE: 813 - 282 -1225 xII15 EMAIL. SHANNONFALGONE®OUTBAGK.GOM FV -3 ECO6RIP (SLIP RESISTANT FLOORING) COLOR: DARK GRAY EGO6RIP FLOORING, LLC FV-4 VINYL FLOORING — COLOR: ALMOST BLACK MANNINGTON FV-5 VINYL FLOORING — COLOR: PRINCETON CHERRY MANNIN'TON FY-6 VINYL FLOORING — COLOR: BENGAL TEAK MANNINGTON FV -1 VINYL FLOORING, — COLOR: TOFFEE MANNINGTON MARBLE TRANSITION STRIP - COLOR: BLACK GENERAL NOTES A. 6.G. OR 051 PM TO CONTACT SHANNON FALCONE (813- 282 —I225 XI115) IN THE 051 CONSTRUCTION DEPARTMENT FOR ORDERING AND SGHEDULINS ALL FLOORING MATERIAL. B. 6.G. TO UNLOAD AND STORE FLOORING MATERIAL FOR FLOORING SUB — CONTRACTOR. C. 6.G. TO PROVIDE USE OF 6.G.'s DUMPSTER TO FLOORING SUB — CONTRACTOR. t)11,4-00G INOMENS RESTROOM DINING AREA An . I dr H k i' ■■ r•�!�!�!.!.A - - - - - - - - - - - - •7 -' - - - - - aL1►! - - - - - - - - - - - Jlcllll7Trrrlrl'.rt.GGrfffl 0 si _ �►1 O PLATFORM cusTOMMR WAITING A vESTISULE ■ 0 PLATFORM IMONIL ;•.!.!:! :!:!:!:! :! :age.!:! :! :!:!:!:!:! :! :!:l :.: V ' c i ” i . ' .. 2 ' ► a P W Ci�i�i�A 1 I I • 1 I 11T:::1 :J Ealaij Zj g • A DINING AREA FLOOR FINISH PLAN • • 1 J UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE-PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t425.747.3177 f.425.747.7149 www.mlarch.com stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title FLOOR FINISH PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 6 2012 City of Tukwila BUILDING DIVISION RECEIVED _ CITY OFTUK9VIlA JAN A+ 2012 PERMIT CENTER drawn by MSC checked by A 8.18.2011 Corp changes issued date description A3.1 LIGHT FIXTURE SCHEDULE FIXTURE SYMBOL DESCRIPTION /COMMENTS KA KA-I IPON DESCRTI BLAIR COMPANIES: CUSTOM PART #OSHLEL_00002 LED LIGHT BAR WITH MOUNTING CLIPS AND DIMMER. 80 LUMENIW, 4.51N, 5500K, WARM WHITE, I2VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 I2VDG TRANSFORMER. TYPICAL (2)5' -8" LENGTHS, (2)80W MEAN/NELL POWER SUPPLIES BLAIR COMPANIES: CUSTOM PART #OSH_EL_00001 L=17 LIGHT BAR WITH MOUNTING, CLIPS AND DIMMER. 80 LUMEN/W, 4.51N, 35OOK, WARM WHITE, I2VDG VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED GLASS 2 12VDG TRANSFORMER. TYPICAL (4)7" -6" LENGTHS, (2)801N MEAWELL POWER SUPPLIES KB -I, KS-S K15-I K13-2 KB -3 0 • CON -TECH LVR 3I6 -GTR 325-8, SYL 5OMRI6 /SPIO /C (EXT I2V). USE WITH SOLITE MR -16 LENS SAME AS KB -I EXCEPT FOR LOW IRON MR -I6 FROSTED LEN5 SAME AS KB -I EXCEPT WITH LINEAR SPREAD LENS. ROTATE LENS VERTICALLY TO PROTECT LIGHT HORIZONTALLY. INSTALL LENS WITH TEXTURE EXPOSED ON OUTSIDE OF FIXTURE SAME AS KB-I EXCEPT FOR HEXAGON LOUVER KG -I KC -4 0 CON -TECH LVR 316 WITH GTR302 -15-BLK TRIM, SYL 50MRI6 /SPIO /G (EXT 12V). USE WITH SOLITE LENS SAME AS KG -I EXCEPT FOR HEXAGON LOUVER KD KD -I KD-2 KD-4 KD -M ACOUSTICAL LAY -IN CEILING TILE SPOT LIGHT/RECESSED. WINDOW TREATMENTS CON -TECH MGT- 2116-(B), SYL 50MRI6 /SPIO /C (EXT 12V) WITH CLEAR LENS SAME AS KD EXCEPT FOR SOLITE LENS SAME AS KD EXCEPT FOR LINEAR SPREAD LENS. ROTATE LENS VERTICALLY TO PROJECT LIGHT HORIZONTALLY. INSTALL LENS WITH TEXTURE EXPOSED ON OUTSIDE OF FIXTURE SAME AS KD -2 EXCEPT FOR SOLITE LENDS AND THE FOLLOWING, ADJUSTMENTS: (5) LA5O -15 ADJUSTABLE MOUNT (5) STEM BARS (I2 ", 24" AND 56" GUT TO LENGTHS- F.V.) (I) LAIO -B CONNECTOR (8) EG6YOLK LIGHTS SUSPEND FROM CEILING ABOVE CON -TECH MONO -POINT ADAPTOR, MLA- I4 -(B). SAME AS KD EXCEPT WITH LINEAR SPREAD LENS _ ® KE 4 LED WAVES: MODEL LW20_2100_A22_E3G_W27OOK - POWER SUPPLY L1N20- IIOO- A- DC815I4 (NON - DIMMING MODULE) LENGTH T.B.D. - LINEAR LED SURFACE MOUNTED ADHESIVE MULTI -LAMP LED TAPE WITH REMOTE DRIVERS. 120 DEGREE BEAM SPREAD; LAMPS 1/2" O.G., WET LISTED. 091 SUPPLIED /CONTRACTOR INSTALLED 6 FG KF -I ® (DOWN LIGHT) CON-TECH LVR 516 WITH CTR305 -15-15LK TRIM - SYL SOMRI6 /SPIO /C(EXT I2V). USE WITH SOLITE LENS LTI LTI -E 6 FG (PENDANT) CUSTOM PENDANT BY NAUTICAL FURNISHINGS, INC. MOUNTED AT 25" ABOVE TABLE TO BOTTOM OF SHADE. LAMP: SATCO 54500 EXISTING WANT TO REMAIN, REPLACE SHADE TO MATCH NEW PENDANTS LT2.IA LT2.IB LT2.IC MONO POINT LIGHT: BAR LIQUOR BOTTLES PENDANT 15 INTEGRATED WITH CEILING FEATURE. LAMP: EDISON SQUIRREL GAGE PENDANT 15 INTEGRATED WITH CEILING FEATURE. LAMP: EDISON HAIRPIN 401N PENDANT 15 INTEGRATED WITH CEILING FEATURE. LAMP: EDISON QUAD LOOP KG -I LT -3 DOWN LIGHT: DINING AREA PENDANT 15 INTEGRATED WITH CEILING PANEL. A, B, AND C DESIGNATE MOUNTING HEIGHT PRESET BY NAUTICAL FURNISHINGS, INC. LAMP: SATCO GROWN CHROME A6014 LT -4 17-7 (AUSTRALIA MAP LIGHT) CUSTOM FIXTURE BY NAUTICAL FURNISHINGS, INC. REFER TO DETAIL B / L -1 5 -6 FG (V.I.F.) KD -I TI T2 TI- TRACK -CON -TECH MLT -4-B. (4' -O ") TRACK TI- TRACK -CON -TECH MLT -6-15. (6' -0") TRACK 15-20 Fa (v.I.F.) ES 17-4 EXISTING EXTERIOR WALL SCONCE; 6.0. TO REPLACE WHITE SHADE WITH NEW BRONZE SHADE PROVIDED BY REXEL. DOWN LIGHT: VESTIBULE ED ED -I Q EXISTING DOWNLIGHT EXISTING DOWNLI6HT: PROVIDE AND INSTALL SYL 5OMRI6 /SPIO /G (EXT I2V) BULB AND SOLITE LENS IN EXISTING FIXTURE. DIMMER PANEL SCHEDULE FIXTURE X J CIRCUIT DIMMER DIMMER SWITCH IPON DESCRTI DIMMER SETTING AT POSITION 5 (DARK) KB -I, KS-S `fl D -I 4 SPOT LIGHT/RECESSED: PERIMETER ART 50 FG (SINGLE) 50 FG (MULTIPLE) KB -2 D -2 ACOUSTICAL LAY -IN CEILING TILE SPOT LIGHT/RECESSED. WINDOW TREATMENTS 20 FG (TYPICAL) 25 Fc (HOT SPOTS) KG -I 12-3 4 DOWN LIGHT: BAR TABLES 6 FG KF -I 12-4 CENTER FIXTURE IN NICHE, OR AS CLOSE AS ACOUSTICAL GRID WILL ALLOW DOWN LIGHT: BAR SOFFIT 6 FG K15-1, KD -M D -5 MONO POINT LIGHT: BAR LIQUOR BOTTLES VERIFY IN FIELD KG -I D -6 DOWN LIGHT: DINING AREA 6 FG KD-2 17-7 SPOT LIGHT/TRACK: BAR SCREEN WALLS 5 -6 FG (V.I.F.) KD -I 17-8 SPOT LIGHT/TRACK: FRESH WALL 15-20 Fa (v.I.F.) KB -I, KC-1 17-4 DOWN LIGHT: VESTIBULE 10 .FG ar 48" A.F.F. KG -I, KG -4 D -4 SPOT LIGHT/RECESSED. HOST 4 CUSTOMER WAITING 2 -5 FG ON HOST STAND KB -I 0-10 SPOT LIGHT/RECESSED. BACK SIDE OF STACK WALLS 2.5 -5.5 FG ® CENTER OF WALL LT-4 D -II CHANDELIER: "DOWN UNDER" FIXTURE ® CUSTOMER WAITING (STACK I ONLY) VERIFY IN FIELD KE D _ D -I3 BOTTLE STEP DISPLAYS 4 COLUMNS VERIFY IN FIELD KE DS BAR WALL MOUNTED HALF LOUVER CABINETS (FRESH ONLY) VERIFY IN FIELD KA -I DS BAR LOUVER CABINETS (STACK 1 PROTO) FULL ON (V.I.F.) KA OM D5 CUSTOMER 1NAITIN6 SIDE OF STACK WALLS 8 -4 FG ® CEILING: LTI -E SI d tu 0 tn 1 D -I4 WANT LIGHT: PERIMETER BOOTHS 20 FG LT3 D -15 BAR BACK WALL 4 BAR CEILING, VERIFY IN FIELD (CAREFUL ® TV's) LT2.I (A,B,G) D -I6 CHANDELIER: DINING AREA 2 FG @ 18" BELOW LAMP ED D -17 DOWN LIGHT: DINING WALK AISLES 1.5 FG co 48" A.F.F. ED D -IS DOWN LIGHT: KITCHEN ENTRY 4 BAR WALK AISLES 1.5 FG at 48" A.F.F. GENERAL NOTES A. RELOCATE HVAG SUPPLY/RETURN AT RAISED BAR SOFFIT TO NEW MILLWORK SOFFIT. SEE D /A5.I B. EXISTING AISLE DOWN LIGHTING IN DINING AREAS TO BE RE- CENTERED ON AISLE AND CIRCUITED TOGETHER. COORDINATE WITH 051 PM. G. LIGHT FIXTURES ARE A NON - SUBSTITUTE, LONG LEAD ITEM. ORDER ALL FIXTURES THROUGH REXEL -USA, ATTENTION KATHY ORBENDORFER (I -800 -486- 3256). FOR ORDER DISCREPANCIES OR OTHER LIGHTING FIELD ISSUES, CONTACT SHANNON FALCONE AT OSI (813- 282 -I225 EXT. II15). D. REMOVE AND DISPOSE OF ALL. PINK WALKWAY LAMPS. REPLACE WITH WHITE LAMPS. E. PORCH/PATIO DOWN LIGHTS - OFF DIMMER TO EXTERIOR TIME CLOCK. F. EXTERIOR WALL SCONCES, SOFFIT LIGHTS, AND WALL PACK LIGHTS - OFF DIMMER TO EXTERIOR TIME CLOCK. G. EXISTING AISLE DOWN LIGHTS IN BAR/LOUNGE AREA TO BE RE- CENTERED ON AISLE AND CIRCUITED TOGETHER. COORDINATE WITH OSI PM. H. REMOTE TRANSFORMERS, WHEN NOTED, REQUIRE THE FIXTURE MANUFACTURER (OR E.G.) TO SUPPLY LOW VOLTAGE TRANSFORMERS WITH ENCLOSURES AND TO GOORD I NATE THE SIZE AND QUANTITY W I TH THE MANUFACTURER (OR E.G.). CONTRACTOR TO PROVIDE FUSE FOR SECONDARY WIRING. TRANSFORMERS TO BE IN WELL VENTILATED AND ACCESSIBLE REMOTE LOCATION AS SELECTED BY ARCHITECT /INTERIOR DESIGNER. CONTRACTOR TO COORDINATE MOUNTING DETAILS AND ELECTRICAL CONNECTIONS. ADVISE MANUFACTURER OF LEAD LENGTHS AND VERIFY INSTALLATION COMPLIES WITH NATIONAL, STATE, AND LOCAL CODES. FIXTURE MANUFACTURER TO DETERMINE REQUIRED WIRE SIZE BETWEEN SOCKETS AND TRANSFORMERS, NUMBER OF LAMPS PER CIRCUIT, AND TO VERIFY THAT VOLTAGE DROP DOES NOT EXCEED 5 %. SEC MILLWORK SHOP DRAWINGS TO DETERMINE STRIP LIGHT LENGTHS AND MOUNTING DETAILS. I. KB -1, KB -2, K5 -3, 4 KB -4 RECESSED HOUSINGS TO BE ADJUSTED AS NEEDED TO FIT ACOUSTICAL CEILING. COORDINATE WITH 051 PM. J. ALL EXISTING WHITE CEILING MOUNTED EMERGENCY LIGHTS OR EXIT SIGNS TO BE REPLACED WITH BLACK FIXTURES. COORDINATE WITH 051 PM. K. ALL CEILING GRID, ACCESSORIES, HVAC SUPPLIES/RETURNS, SPEAKERS, ETC. TO BE PAINTED (P -3). SEE SHEET A5.5 FOR FINISH SCHEDULE. COORDINATE WITH 051 PM. L. RELOCATE EXISTING HVAG SUPPLIES/RETURNS AS REQUIRED TO CLEAR NEW DESIGN ELEMENT CONNECTIONS ATTACHED TO CEILING. COORDINATE WITH 051 PM. M. ALL PENDANT AND RECESSED TABLE LIGHTING TO BE CENTERED IN BOTH DIRECTIONS OVER TABLE TOPS AS CLOSE AS ACOUSTICAL GRID WILL ALLOW. N. ALL KB -I LIGHT FIXTURES TO BE MOUNTED AT 2' -4" FROM GYPSUM BOARD. 0. ALL K5-2 LIGHT FIXTURES TO BE MOUNTED AT 1' -6" FROM GYPSUM BOARD. O KEY NOTES 1 (5) LT5 FIXTURES. SEE SHEET EL -I FOR EXACT LOCATION 2 (2) KA -I FIXTURES INSIDE EACH CABINET, VERTICALLY MOUNTED. SEE DETAIL C/L -I 3 REMOTE TRANSFORMER. LOCATE IN CEILING ABOVE LOUVER CABINET 4 KE FIXTURES AT LIQUOR STEPS AND BAR DISPLAY CABINETS 5 CHANDELIER PROVIDED 8Y NAUTICAL FURNISHING, INSTALLED BY E.C. SCC DE TAIL A/L -I FOR LIGHT LOCATIONS 6 ACOUSTICAL LAY -IN CEILING TILE 7 DIMMER PANEL 8 NOT USED 4 RELOCATE EXISTING DOWN LIGHTS) PER DIMENSIONED LOCATION 10 E.G. TO PROVIDE SURFACE MOUNTED DUPLEX RECEPTACLE AT FLOOR OF LOUVER CABINET FOR LED KA -I II CENTER FIXTURE IN NICHE, OR AS CLOSE AS ACOUSTICAL GRID WILL ALLOW 12 CENTER FIXTURE ON WINDOW, OR AS CLOSE AS ACOUSTICAL GRID WILL ALLOW. ALIGN W/ ADJACENT PENDANT IF NOTED 15 ARTWORK - SIZE AND DESIGN VARIES. SCE SHEET A5.5 LT2.1 B '550A' PLAN LT2.1A 19" '550B' PLAN '550C' PLAN \OTE: EXISTI \G LIGHT FIXTURE COU EXISTI \G TO BE REVIOVED THIS REPRESENTS LESS THA FIXTURES. T = 176 = 69 N 60% OF AX CEILING MOUNTED CHANDELIER DETAIL MENS EMPLOY. RESTROOM VL. 00 G LTI -E hElfilrMRE021.4 DININQ A KC -1 KG -1 KG -1 • 0 All=k I j,_tp1ut ��// lI///// /// / /O / /O / / / /O / / / / /// /O / / //, KC -I KG -I KG -I • ie� '' NEW RESTROOM CEILING FRAMING: -2x6 LEDGER 'o.G. -LU26 HA ER (51MPSON OR EQ) -(1) ONE L YER s" GINS PAINT FIXTURE �5oB LTI -E : KC -I KC -1 KC -I KC-1 KG -I ,y O o o o o 0 .: / / / // /. i LTI -E sift"_ - - - - -- - - -. KITCHEN r iI KF1 f'FI Y.F1 r-i r-I 1P1" -� ` S=ii s o i, � KIM I III I I r + L A L L A LT3B I +L I I� I O LT3-G L 3-A I< 1 L , KD-M L II I LT�3 -A �' Ij f + _ Iw- o M L L L A LT8-B L iii ii CuSTOME WAITING AMA KG- in= IT i lillg Eli Ii Iat idl OM r iI KF1 f'FI Y.F1 r-i r-I 1P1" -� ` S=ii s o i, � KIM I III I I r + L A L L A LT3B I +L I I� I O LT3-G L 3-A I< 1 L , KD-M L II I LT�3 -A �' Ij f + _ Iw- o M L L L A LT8-B L iii ii CuSTOME WAITING AMA PI ii `� OE o KG -1 '4 ...a_ %// / / / /I/ / / / //I IF-I KP -1 ler -I rP I t•P-I KF-I - NI 4___-_ '_� �� '� E 4 0 0 0 E O E 1 0 '� KG -I %'- /)0 i 0 o o KG -I L KG -I l KG -1 J l♦ ♦♦♦♦♦♦♦ �_ �i♦ ®�i IXTURE 50C . .; RE OCTE MECHANICAL ELECTRICAL ROOM on-E Liifl I LTI l-E LTI -E LIGHTING FLOOR PLAN UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - .PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com. stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title LIGHTING FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 262012 BUILD BUILDING DIVISION JAN 0 4 2012 PERMIT CENTER drawn by MSC checked by issued date description A4.1 KG- PI ii `� OE o KG -1 '4 ...a_ %// / / / /I/ / / / //I IF-I KP -1 ler -I rP I t•P-I KF-I - NI 4___-_ '_� �� '� E 4 0 0 0 E O E 1 0 '� KG -I %'- /)0 i 0 o o KG -I L KG -I l KG -1 J l♦ ♦♦♦♦♦♦♦ �_ �i♦ ®�i IXTURE 50C . .; RE OCTE MECHANICAL ELECTRICAL ROOM on-E Liifl I LTI l-E LTI -E LIGHTING FLOOR PLAN UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - .PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com. stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title LIGHTING FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 262012 BUILD BUILDING DIVISION JAN 0 4 2012 PERMIT CENTER drawn by MSC checked by issued date description A4.1 3'-6" 11'-41/4 3' -6" 10' -111" [ BAR SOFFIT ] u T ir IC7 e• BACK BAR ELEVATION A 1/2" =1' -0" 1'. ESN 2O-5' 0 CV I1wii■em11 ITEM #522 ] 6'S 112° 7' -1D 112° s -r INSTALL SECTION 5TH c5 INSTALL SECTION 6TH [LAST] INSTALL SECTION 4TH U 9 °,� °^ ►��° a o° p0 N)o o D STACKED WOOD WALL PROVIDED BY MILLWORK CONTRACTOR. " 5 0 oo O°, G.C. TO PAINT BAR SOFFIT PANEL (P -18) ABOVE DECORATIVE PANEL SUPPORT ANGLE. (0 NEW 112" THICK OAK TOP CAP BY G.C. CAP WIDTH AND OVERHANGS TO MATCH EXISTING CAP, STAIN (S-1). Cp NEW 1X4 OAK TRIM BY G.C. DADO BACK SIDE 5116" WIDE X 1" HIGH TO RECEIVE NEW 1/4" THICK PANELING, STAIN (S-1) AS NEEDED. 9 NEW 114° THICK PRE - FINISHED PLYWOOD PROVIDED BY MILLWORK CONTRACTOR INSTALLED BY G.C. OVER EXISTING V- GROOVE PANELING. D ° ° o ' 0G o ° 3/4' PLYWOOD OVER WOOD STUDS. 13 1/2" THICK GYPSUM BOARD OVER EXISTING (MODIFIED) ACOUSTICAL CEILING GRID. G.C. TO PROVIDE SMOOTH PAINTABLE FINISH. PAINT (P -18). 14 EXISTING STRUCTURE ABOVE. 15 I �o nl PANEL D � boa ��� O �0 112" X 1 118" OAK TRIM BY G.C. STAIN (S -1). 19 � ° � 00 �o 0 0n PANEL a fi 1 1/2" X 3 1/2" OAK TRIM BY G.C. STAIN (S-1). aI o O pD D o H O � PANEL �� ° 1 'C' � � O ] 0 p� 0 Q^ D � oo � Q 00.0 �_ PANEL'D' PANEL �0 0 nD � a :tit p � O � I ) J l% �j D 0 O 0 �d a 0 c Q ���o�� PANEL o O: 'E FACE OF EXISTING PLYWOOD ON BACK BAR WALL. o °. a a oQ INSTALL SECTION 1ST INSTALL SECTION 2ND INSTALL SECTION 3R 2' -3" CBAR CEILING PLAN 3/8" =1'-0" 7112" / 1' -7112' T -3" H STACKED WOOD WALL SECTION 2'3" 1. -9. 73" o; m 2 3/8" 6-2 1/8" [NEW LOW WALL - FINISH TO FINISH] 1 T LING HEIGHT 27 m 4 6'-4 1/2" STACK WALL LENGTH 6'-0 5/8" [LIGHT COVE] w (3 U DDETAIL AT BAR SOFFIT 1 1/2" =1' -0" B • 21' -11" [EXISTING RAISED SOFFIT] 3 " -9" 3' -11 1/4° 3' -11 1/4" 3' -11 1/4" 4' -0" Jl 1'-8" \ .11111, F.73111111CF111111111C- ■ = `-- 1 20' -5" [MILLWORK SOFFIT] 21' -9" [EXISTING BAR LENGTH] tT 31" O BAR SECTION 1/2" =1' -0" 0 PANEL 'A' INSTALL SECTION 1ST F BAR CEILING PANELS 1 3/4" [1 -1/2" REVEAL AFTER STACK WALL IS INSTALLED] SHORT STACK WALL PLAN 3/4" = 1' -0" ,4112/ 6'-0 7/8" [EXIST. LOW WALL] 6' -9 7/8" [TOP CAP] 7'4" [NEW LOW WALL - FINISH TO FINISH] X1 3/4" [1 -1/2" REVEAL i, AFTER STACK WALL IS INSTALLED] T-2 1/2" [LIGHT COVE] MLONG STACK WALL PLAN 3/4" = V -0" T-8 1/2" STACK WALL LENGTH PANEL' B' INSTALL SECTION 2ND PANEL'C' INSTALL SECTION 3RD T.CIII111TT.1�J1Z17J1_7//_II.T_ _l1ZIT / 0 0 JDETAIL AT WALL PANELING 1 -1/2" = l' -0° 0 0 0 0 0 DETAIL AT STACK WALL LED LIGHT 1 -112° =1' -0" E DETAIL AT BACK BAR/SOFFIT PANEL 1 " =1' -0" 3' -11 1/4" ti PANEL 'D' INSTALL SECTION 4TH 'oD 1 o r Oh Qa�a PANEL'S' INSTALL SECTION 5TH [LAST] /iii »i�ir iiiiiii DETAIL AT BACK BAR CEILING 0 0 0 0 0 K //_ DETAIL AT WALL PANELING 1/2" =1' -0" L ALIGN OUTSIDE FACE OF TRIM TO NEW OAK (EBONY) TOP CAP ABOVE DETAIL AT WALL PANELING 1 -1/2" =1' -0" DETAIL AT WALL PANELING 1 -1 /2" =1' -0" QWALL PANELING DETAIL AT FULL WALL 1 -1/2" =1' -0" P DETAIL AT WALL PANELING 1 -1/2" =1' -0" LOW WALL SECTION 314 " = l'-0 GENERAL NOTES A. ALL ITEMS NOTED AS 'BY MILLWORK CONTRACTOR' ARE TO BE INSTALLED BY G.C. B. ALL ITEMS NOTES AS 'BY DECOR CONTRACTOR' ARE TO BE INSTALLED BY G.C. C. REFER TO SHEET A5.3 FOR INTERIOR FINISH SCHEDULE. D. ALL SHEET NOTES MAY NOT APPLY. Q KEY NOTES 1 CEILING 2 LED LIGHT PROVIDED BY MILLWORK CONTRACTOR. 3 STACKED WOOD WALL PROVIDED BY MILLWORK CONTRACTOR. 4 LIQUOR STEPS BY MILLWORK CONTRACTOR. 5 G.C. TO ADD (2EA.) SPRINKLER HEADS TO INSIDE VERTICAL FACE OF NEW BAR SOFFIT. COORDINATE WITH OSI P.M. 6 G.C. TO PAINT BAR SOFFIT PANEL (P -18) ABOVE DECORATIVE PANEL SUPPORT ANGLE. 7 NEW 112" THICK OAK TOP CAP BY G.C. CAP WIDTH AND OVERHANGS TO MATCH EXISTING CAP, STAIN (S-1). 8 NEW 1X4 OAK TRIM BY G.C. DADO BACK SIDE 5116" WIDE X 1" HIGH TO RECEIVE NEW 1/4" THICK PANELING, STAIN (S-1) AS NEEDED. 9 NEW 114° THICK PRE - FINISHED PLYWOOD PROVIDED BY MILLWORK CONTRACTOR INSTALLED BY G.C. OVER EXISTING V- GROOVE PANELING. 10 NEW 1X6 OAK BASE. STAIN (5-1). 11 BAR SOFFIT BY MILLWORK CONTRACTOR. 12 3/4' PLYWOOD OVER WOOD STUDS. 13 1/2" THICK GYPSUM BOARD OVER EXISTING (MODIFIED) ACOUSTICAL CEILING GRID. G.C. TO PROVIDE SMOOTH PAINTABLE FINISH. PAINT (P -18). 14 EXISTING STRUCTURE ABOVE. 15 1/2" PLYWOOD OVER WOOD STUDS. 16 1" X 1 112" OAK TRIM BY G.C. STAIN (5-1). 17 1X4 OAK TRIM BY G.C. STAIN (S -1). 18 112" X 1 118" OAK TRIM BY G.C. STAIN (S -1). 19 STACK WALL MOUNTING BRACKET BY MILLWORK CONTRACTOR. 20 2X BLOCKING. 21 1 1/2" X 3 1/2" OAK TRIM BY G.C. STAIN (S-1). 22 3/4" BC GRADE PLYWOOD. SMOOTH SIDE EXPOSED. PAINT (P -5). 23 EXISTING 1X4 TRIM TO REMAIN. 24 EXISTING 1X6 BASE TRIM TO REMAIN. 25 EXISTING 1X6 V- GROOVE PANELING TO REMAIN. 26 G.C. TO INSTALL NEW 114" PANELING TIGHT TO BOTTOM OF EXISTING 1X4 APRON TRIM , OVER EXISTING V- GROOVE. 27 EXISTING SLOPED OAK CAP AT FULL HEIGHT WALL. 28 EXISTING TEXTURED VENEER FINISH (STUCCO). 29 OPEN 30 END OF SOFFIT 31 FACE OF EXISTING PLYWOOD ON BACK BAR WALL. 32 3" X 3" METAL ANGLE BEHIND VERTICAL PANEL. ANGLE TO STOP AT FACE OF DISPLAY CABINET. 33 FACE OF VERTICAL PANEL. 34 REMOVABLE PANELS BY DECOR CONTRACTOR. PENDANTS ARE INTEGRATED WITH PANELS. G.C. TO INSTALL BULBS PER SPECIFICATION ON SHEET A4.1 35 3" X 3" CONTINUOUS METAL SUPPORT ANGLE BY DECOR CONTRACTOR. 36 1" X 1" REVERSE ANGLE FOR VERTICAL PANEL SUPPORT. PROVIDED BY DECOR CONTRACTOR. 37 KD -M FIXTURE. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET A4.1 38 NEW 1 X 6 V- GROOVE PANELS TO MATCH EXISTING. STAIN TO MATCH EXISTING PANELING. 39 2 X 10 WOOD STUDS AT 16" O.C. 40 2 X 10 PRESSURE TREATED WOOD PLATE. 41 PLEXI -GLASS SHIELD. SUPPLIED BY MILLWORK CONTRACTOR. G.C. TO CUT TO FIT. 42 CLASSIC TOP CAP TO REMAIN. BUTT -JOINT WITH NEW TOP CAP. 43 EXISTING A.C.T. SOFFIT. ADJUST AS NEEDED TO FIT WITH NEW MILLWORK SOFFIT. 44 WOOD BLOCKING AS NEEDED TO FUR OUT SUPPORT ANGLE. 45 OPEN 46 THREADED. ROD TO UNI -STRUT ABOVE. THREADED ROD BY MILLWORK CONTRACTOR. UNI -STRUT IS BY G.C. 47 TITUS 272 FL 16" X 4" DOUBLE DEFLECTION SUPPLY AIR GRILL G.C. TO PAINT TO MATCH STAINED SOFFIT COLOR. 48 FINISHED FACE OF BACK BAR MILLWORK PANEL 49 G.C. TO NOTCH NEW TOP CAP BACK TO FACE OF EXISTING LOW WALL. 50 MOUNTING CLEAT (SHADED) BY MILLWORK CONTRACTOR. CLEAT TO BE INSTALLED PER DETAILS G & H /DTL -2. 51 1 1/2" X 13/4" OAK TRIM. STAIN (S-1). 52 NEW 1X 6 PINE BASE. STAIN TO MATCH EXISTING ADJACENT BASEBOARDS. (S-4) TYPICAL. 53 OPEN 54 OPEN 55 OPEN 56 OPEN 57 OPEN 58 OPEN 59 OPEN 60 OPEN 61 OPEN 62 OPEN 63 OPEN 64 318" X 1 1/2" OAK BATTEN STRIPS (ITEM #507F) BY MILLWORK CONTRACTOR. REFER TO WALL BACKING PLAN ON SHEET DTL -2 FOR BATTEN STRIP LOCATIONS. 65 ACCESSIBLE SIGN TO BE MOUNTED ON SAME SIDE AS PUSH PLATE/OPPOSITE HINGE SIDE. SIGN SHALL COMPLY WITH ICC /ANSI A117.1 -2003 AND LOCAL CODE. 66 G.C. TO REDUCE SIZE OF WOOD WRAP AT STRUCTURAL COLUMNS. G.C. TO ADHERE NEW 1X OAK TRIM DIRECTLY TO STRUCTURAL COLUMN. STAIN (5-4). 67 1/4" REVEAL - TYPICAL. 68 UPPER PART OF ANGLE SUPPORT BRACKET TO BE PAINTED (P -18). 69 1" STAINLESS STEEL PIPE PRE - MANUFACTURED WITH 90 DEGREE TURN DOWN. 70 G.C. TO ATTACH FLEXIBLE DRAIN HOSE TO 90 DEGREE TURN DOWN WITH ADJUSTABLE PIPE CLAMP. 71 G.C. TO PROVIDE FLEXIBLE DRAIN HOSE TO FLOOR SINK/DRAIN. 72 ELECTRICAL FEED FROM ABOVE. ROUTE THROUGH STACK WALL CHASE TO LOW WALL. 73 G.C. TO REMOVE PORTION OF SLOPED TOP CAP TO ALLOW FOR ITEM #548E (WALL MOUNTED LOUVER CABINET) TO REST ON EXISTING 1X APRON TRIM. 005 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 6 2012 City of Tukwila BUILDING DIVISION UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any at herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 """ Set. drawing title DETAILS RECEIVED_ OF TUK1MLA JAN 0 4 2012 PERMIT CENTER drawn by MSC checked by issued date description A5.1 3/4" =1' -0" 3/4" =1'-0" B 3/4" =1' -0" V -0" 6" EPAGER CABINET DETAIL 3/4" =1' -0" 1 3" DETAIL AT BACK BAR 1.= v_cr J SECTION AT UNDER BAR GLASS STORAGE CABINET 1" =1' -0" rrrrrrrrrrrrrr.I r CWALL PANELING PLAN 318" =1' -0" 51/2" FDETAIL AT COLUMN 1 -1/2" =1' -0" CO 47 3/4" [FROM FACE OF EBONY PLYWD. PANELS TO FACE OF STACK WALL STARTEFj STRIP] GDETAIL AT STACK WALL 1 -1/2" =1' -0" 3/4" [FROM EXISTING WALL FINISH TO STACK WALL TARTER STRIP] HDETAIL AT STACK WALL 1 -112" =1'-0 GENERAL NOTES A. ALL ITEMS NOTED AS 'BY MILLWORK CONTRACTOR' ARE TO BE INSTALLED BY G.C. B. ALL ITEMS NOTES AS 'BY DECOR CONTRACTOR' ARE TO BE INSTALLED BY G.C. C. REFER TO SHEET A5.3 FOR INTERIOR FINISH SCHEDULE. D. ALL SHEET NOTES MAY NOT APPLY. 0 KEY NOTES 1 CEILING 2 LED LIGHT PROVIDED BY MILLWORK CONTRACTOR. 3 STACKED WOOD WALL PROVIDED BY MILLWORK CONTRACTOR. 4 LIQUOR STEPS BY MILLWORK CONTRACTOR. 5 G.C. TO ADD (2EA.) SPRINKLER HEADS TO INSIDE VERTICAL FACE OF NEW BAR SOFFIT. COORDINATE WITH OSI P.M. 6 G.C. TO PAINT BAR SOFFIT PANEL (P -18) ABOVE DECORATIVE PANEL SUPPORT ANGLE. 7 NEW 1/2" THICK OAK TOP CAP BY G.C. CAP WIDTH AND OVERHANGS TO MATCH EXISTING CAP, STAIN (S -1). 8 NEW 1X4 OAK TRIM BY G.C. DADO BACK SIDE 5/16" WIDE X 1" HIGH TO RECEIVE NEW 1/4" THICK PANELING, STAIN (S-1) AS NEEDED. 9 NEW 1/4" THICK PRE - FINISHED PLYWOOD PROVIDED BY MILLWORK CONTRACTOR INSTALLED BY G.C. OVER EXISTING V- GROOVE PANELING. 10 NEW 1X6 OAK BASE. STAIN (5-1). 11 BAR SOFFIT BY MILLWORK CONTRACTOR. 12 314" PLYWOOD OVER WOOD STUDS. 13 1/2" THICK GYPSUM BOARD OVER EXISTING (MODIFIED) ACOUSTICAL CEILING GRID. G.C. TO PROVIDE SMOOTH PAINTABLE FINISH. PAINT (P -18). 14 EXISTING STRUCTURE ABOVE. 15 112" PLYWOOD OVER WOOD STUDS. 16 1 "X 1 1/2" OAK TRIM BY G.C. STAIN (S-1). 17 1X4 OAK TRIM BY G.C. STAIN (S-1). 18 1/2" X 11/8" OAK TRIM BY G.C. STAIN (S-1). 19 STACK WALL MOUNTING BRACKET BY MILLWORK CONTRACTOR. 20 2X BLOCKING. 21 1112" X 3112" OAK TRIM BY G.G. STAIN (S -1). 22 we BC GRADE PLYWOOD. SMOOTH SIDE EXPOSED. PAINT (P-5). 23 EXISTING 1X4 TRIM TO REMAIN. 24 EXISTING 1X6 BASE TRIM TO REMAIN. 25 EXISTING 1X6 V- GROOVE PANELING TO REMAIN. 26 G.C. TO INSTALL NEW 1/4" PANELING TIGHT TO BOTTOM OF EXISTING 1X4 APRON TRIM , OVER EXISTING V- GROOVE. 27 EXISTING SLOPED OAK CAP AT FULL HEIGHT WALL. 28 EXISTING TEXTURED VENEER FINISH (STUCCO). 29 OPEN 30 END OF SOFFIT 31 FACE OF EXISTING PLYWOOD ON BACK BAR WALL. 32 3" X 3" METAL ANGLE BEHIND VERTICAL PANEL. ANGLE TO STOP AT FACE OF DISPLAY CABINET. 33 FACE OF VERTICAL PANEL. 34 REMOVABLE PANELS BY DECOR CONTRACTOR. PENDANTS ARE INTEGRATED WITH PANELS. G.C. TO INSTALL BULBS PER SPECIFICATION ON SHEET A4.1 35 3" X 3" CONTINUOUS METAL SUPPORT ANGLE BY DECOR CONTRACTOR. 36 V X 1" REVERSE ANGLE FOR VERTICAL PANEL SUPPORT. PROVIDED BY DECOR CONTRACTOR. 37 KD-M FIXTURE. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET A4.1 38 NEW 1 X 6 V- GROOVE PANELS TO MATCH EXISTING. STAIN TO MATCH EXISTING PANELING. 39 2 X 10 WOOD STUDS AT 16" O.C. 40 2 X 10 PRESSURE TREATED WOOD PLATE. 41 PLEXI -GLASS SHIELD. SUPPLIED BY MILLWORK CONTRACTOR. G.C. TO CUT TO FIT. 42 CLASSIC TOP CAP TO REMAIN. BUTT -JOINT WITH NEW TOP CAP. 43 EXISTING A.C.T. SOFFIT. ADJUST AS NEEDED TO FIT WITH NEW MILLWORK SOFFIT. 44 WOOD BLOCKING AS NEEDED TO FUR OUT SUPPORT ANGLE. 45 OPEN 46 THREADED ROD TO UNI -STRUT ABOVE. THREADED ROD BY MILLWORK CONTRACTOR. UNI-STRUT IS BY G.C. 47 TITUS 272 FL 16" X 4" DOUBLE DEFLECTION SUPPLY AIR GRILL. G.C. TO PAINT TO MATCH STAINED SOFFIT COLOR. 48 FINISHED FACE OF BACK BAR MILLWORK PANEL. 49 G.C. TO NOTCH NEW TOP CAP BACK TO FACE OF EXISTING LOW WALL. 50 MOUNTING CLEAT (SHADED) BY MILLWORK CONTRACTOR. CLEAT TO BE INSTALLED PER DETAILS G & HJDTL -2. 51 1 1/2" X 1 314" OAK TRIM. STAIN (S -1). 52 NEW 1X 6 PINE BASE. STAIN TO MATCH EXISTING ADJACENT BASEBOARDS. (S -4) TYPICAL. 53 OPEN 54 OPEN 55 OPEN 56 OPEN 57 OPEN 58 OPEN 59 OPEN 60 OPEN 61 OPEN 62 OPEN 63 OPEN 64 3/8" X 1 1/2" OAK BATTEN STRIPS (ITEM #507F) BY MILLWORK CONTRACTOR. REFER TO WALL BACKING PLAN ON SHEET DTL -2 FOR BATTEN STRIP LOCATIONS. 65 ACCESSIBLE SIGN TO BE MOUNTED ON SAME SIDE AS PUSH PLATE/OPPOSITE HINGE SIDE. SIGN SHALL COMPLY WITH ICC /ANSI A117.1 -2003 AND LOCAL CODE. 66 G.C. TO REDUCE SIZE OF WOOD WRAP AT STRUCTURAL COLUMNS. G.C. TO ADHERE NEW 1X OAK TRIM DIRECTLY TO STRUCTURAL COLUMN. STAIN (S-4). 67 1/4" REVEAL - TYPICAL. 68 UPPER PART OF ANGLE SUPPORT BRACKET TO BE PAINTED (P -18). 69 1" STAINLESS STEEL PIPE PRE - MANUFACTURED WITH 90 DEGREE TURN DOWN. 70 G.C. TO ATTACH FLEXIBLE DRAIN HOSE TO 90 DEGREE TURN DOWN WITH ADJUSTABLE PIPE CLAMP. 71 G.C. TO PROVIDE FLEXIBLE DRAIN HOSE TO FLOOR SINK/DRAIN. 72 ELECTRICAL FEED FROM ABOVE. ROUTE THROUGH STACK WALL CHASE TO LOW WALL. 73 G.C. TO REMOVE PORTION OF SLOPED TOP CAP TO ALLOW FOR ITEM #548E (WALL MOUNTED LOUVER CABINET) TO REST ON EXISTING 1X APRON TRIM. 0 () REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 6 201t City of`%kwilU BUILDING DIVISION UNPUBLISHED WORK 0 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any pert herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 " set drawing title DETAILS cmo�n�'u►u JAN U it 2012 PERMIT CENTER drawn by MSC checked by issued date description A5.2 P-12 RA-34A �^�v�,�nm*u/mu^�n � ,"v=`=.~�.�"""°" SQUASH COLOR) 1 inn/m11 EMMEN 1=IMMIM• 1■••/1 inn/M/S ■••■• arm s aus P-12 -27 FRESH ART J RA-25 P-12 RA22 P-12 RA-14A P-12 • • � |! | \ / /� GENERAL NOTES A. ALL ARTWORK TO BE CENTERE ON WALL BOT HORIZONTALLY AND VERTICALLY AS SI-IOWN. (UNLESS NOTED OTHERWISE) `"' B. MANAGING PARTNER IS RESPONSIBLE FOR REPAIRING ALL BROKEN BOOTHS AND BOOTH ENDS PRIOR TO REMODEL COMPLETION. c. MANAGING PARTNER S RESPONSIBLE FOR REPAIRING ALL EXISTING WAINSCOT, CAP, APRON, & BASEBOARD WHERE DISCOLORATION AND OTHER DEFECTS EXIST. D. SEE SHEET FS- FOR CEILING AND LOW WALL HEIGHTS E. ALL ITEMS NOT LABELED ON INTERIOR ELEVATIONS ARE TO REMAIN IN EXISTING CONDITION AND LOCATION F. G.C. TO PAINT ALL INTERIOR HOLLOW METAL DOOR FRAME DARK BRONZE. FINISH: PAINT (P-10) G. AFTE ADJUSTING LIGHTING FOR DECOR, ELECTRICAL CONTRACTOR TO TIGHTEN SET SCREWS TO ADJUSTE POSITION. H. G.C. IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL EXISTING DECOR. ALL DECOR � DINING AREAS, BAR AREAS, TAKE AWAY AREA, SERVICE AISLES, KITCHEN ENTRANCES, RESTROOMS, ETC. MUST BE REMOVED UNLESS SPECIAL APPROVAL IS OBTAINED FROM 051 DESIGN. COORDINATE DISPOSAL WITH MANAGING PARTNER. o —f \ o • ( x U o / —I _ _ ~ " / H U P-16 TYP. Si Pi in P-12 \^�/ 0 KEY NOTES n^u—n O/^—S SPECIFICATION MANUFACTURER/CONTACT 1 NEW WOOD DOOR. FINISH: STAIN (S-5) 2 EXISTING EXIT SIGN TO REMAIN 3 EXISTING FIRE STROBE TO REMAIN 4 EXISTING EMERGENCY LIGHT TO REMAIN 5 NEW 1X6 OAK BASE. FINISH: STAIN (5-1) 6 1/4" OAK PLYWOOD BY MILLWORK CONTRACTOR. G.C. TO INSTALL OVER EXISTING 1X6 V-GROOVE (SHOWN SHADED) SEE WALL PANELING PLAN ON SHEETA5.2 7 BAR TOP 8 IX HARDIETR!M. HNISH: PAINTTO MATCH EXISTING TRIM 9 EXISTING THERMOSTAT TO REMA!N 10 HD1V. SEE SHEET A2.1 FOR EXACT LOCATION 11 NEW SMOOTh DRYWALL FINISH (TBD BY OSI DESIGN DEPARTMENT) 12 1X4 PINE TRIM. F!NISH: STAIN (S-4). ONLY ADDED WHEN PROVIDING SMOOTh DRYWALL FINISH. 13 00 NOT INSTALL 1X6 BASEBOARD BEHND WAITING BENCH (1YPICAL) 14 G.C. TO MOUNT ARTICULATING ARM BRACKET BASE ON THIS SIDE OF TV CABINET. WHEN MOUNTED AND TV IS FLUSH AGAINST CABINET, 1V SHOULD BE CENTERED IN CABINET AND THE TOP SHOULD ALIGN WITH TOP OF CABINET 15 AT FRESH/STEAK ART, GC TO REMOVE LAG SCREWS FROM CORNERS AND FASTEN ART TO WALL USING PROVIDED SCREW HOLES. G.C. TO RE-NSERT DECORATIVE LAG SCREWS IN ORDER TO CONCEAL FASTENERS 200 EXISTING EMERGENCY LIGHT TO BE RELOCATED 201 EXISTING PORTABLE FIRE EXTINGUISHER TO REMAIN 202 EXISTING FIRE PULL STATION TO REMAIN C-1 &4)(48"x.5° LAY-IN CEILING TILE FACTORY PAINTED "HALE NAVY' OR INTERIOR FINISH SCHEDULE FINISH SPECIFICATION MANUFACTURER/CONTACT P-3 PAINT0NHC164'HALENAVY^'MAJTEFINISH BENJAMIN MOORE P-5 PAINT: 'DUTBACK BLACK - SATIN FINISH SHERWIN-WILLIAMS CONTACTJOE8D[THS PHONE: 407-948-4671 EMA|L:JOSEPH.P.BOOTHS@SHERW|N.00M P-10 PAINT: SNGO8Q "FRENCH ROAST" ' ENAMEL LATEX ' LOW SHEEN SHERWIN-WILLIAMS/SEE P-5 P'12 PAINT: ^HU88ARD SQUASH" ' EGGSHELL FINISH SHERWIN-WILLIAMS/SEE P-5 P-15 PAINT: BM 545 "BUCKINGHAM GARDENS" - EGGSHELL FINISI-I BENJAM|NMOORE P'18 PAINT: SN8G2Q"JALAPENOr' SATIN FINISH SHERWIN-WILLIAMS/SEE P-5 P-17 PAINT: BM3171-3Q "ADOBE ORANGE" ' SATIN FINISH BENJAMIN MOORE P-18 PAINT: BM 2OG340°SA|UDRS SEA BLUE" ' SATIN FINISH BENJAMIN MOORE S-1 STAIN: 'EBONY' - SI-IER-WOOD BAC WIPING STAIN MINWAX CONTACT: JOE BOOTHS PHONE: 407-948-4671 EMAIL: JOSEPH.P. .COM S4 STAIN: 'GOLDEN OAK" & 'PROVINCIAL' 505 MIX ' POLYURETHANE M|NWAXGLOSS APPLY (2) COATS MINIMUM. SAND BETWEEN EACI-I APPLICATION. ADJUST STAIN MIXTURE AS NECESSARY TO MATCH EXISTING. MINWAX/SEE S-1 S-5 STAIN: 930 "PECAN MARINE GRADE FOR EXTERIOR EXPOSURE COLOR WHEEL CONTACT: SHANNON FALCONE PHONE: O13-282-1225XiiiS EMAIL: SHANNONFALCON C-1 &4)(48"x.5° LAY-IN CEILING TILE FACTORY PAINTED "HALE NAVY' CELOTEX CONTAOTS|0OBB|NS PHONE: 813-645-7536 REVIEWED ��� °~~~~"~~~^�� ^ ~^^~ CODE COMPLIANCE � ~ " ������ APPROVED ~�. 2012 City of Tukwila BUILDING DIVISION UNPUBLISHED WORK 0 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or anyist herein without the permission of Merrick Lentz Architect is not permitted MERRICK LENTZ 8Q��|7��� n/��a��� u�mx� ARCHITECT ARCHITECTURE - PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 �25.747.7148 www.mlarch.com stamp consultant project name 1����� /ww:�/SOUTxnCEnnExPKxoY TUKWILA, WA 98188 ... set drawing title INTERIOR ELEVATIONS CITIYSFEtititis �—�` �]0 � � =M�� ~^� PERMiT drawn by MSC checked by issued date description A5.3 2x6 LEDGER w/ 2x6 JOIST ® 24"o .c w/ LU26 HANGER EA JOIST I" 6104B. ATTACHE LEDGER TO EXISTING WALL WITH I6d NAILS 32 "o.c. STAG6ARD r EXISTING WALL, NO MOD IFIGATI ONS EXISTING CONCRETE SLAB dJ DETAIL — NEW CEILING FRAMING SCALE: 3.. = ,._a.. MEN. EMPLOY. RESTROOM MENS RESTROOM 00 40 4® 4® 40 RESTROOM PLAN SCALE: i° = i -o INOMEN5 RESTROOM 00 RESTROOM KEY NOTES I. NOT IN USE P—I. EXISTING CONCRETE SLAB. NEW STAIN AND SEALER APPLIED 2. WALL TREATMENT: ALL WALLS TO RECEIVE ONE LAYER OF NEW 4" M.R. 6043 5-1. PORCELAIN TILE BASE: CROSSVILLE *VS54 APOLLO BRONZE, 6x12. GROUT: TEC *e121 OVERLAY, WIANSGOT TILE (W —I) TO 31-6" A.F.F., WOOD CHAIR —RAIL, AND PAINT / LIGHT PEWTER w/ i" &ROUT JOINTS. FOR PRODUCT CONTACT INTERGOASTAL ABOVE. DISTRIBUTORS — JOHN PALERMO — 813.880.8654 3. 6.G. TO ENSURE THAT SOLID BLK'& IS INSTALLED AT ALL GRAB BAR LOCATIONS, W —I. WALL TREATMENT FOR ALL WALLS WITHIN RESTROOM5: MIRROR LOCATIONS, DISPENSER LOCATIONS, AND ALL OTHER WALL MOUNTED FIXTURES. ABOVE CHAIR —RAIL; SHERWIN— WILLIAMS *SW -0044 "HUBBARD SQUASH" SEMI— GLOSS, WATER BASE EPDXY PAINT OVER LATEX PRIMER BASE GOAT. 4. NOT IN USE. CHAIR -RAIL; TO BE CLEAR PINE AND FINISHED PER RESTROOM KEY NOTE *13 5. NOT IN USE: WAINSCOT TILE; 6X6 CROSSVILLE */554 APOLLO BRONZE w/ is" GROUT JOINTS. FOR 6. NOT IN USE. PRODUCT CONTACT INTERGOASTAL DISTRIBUTORS — JOHN PALERMO — 813.880.8654 1. COUNTER TOP AND BAGKSPLASH: SOLID SURFACE, "GORIAN" COLOR "MOSS ", 1" G —I. NEW 6W13 HARD —LID PER PLAN AND DETAIL THICK. FOR LOCAL FABRICATOR GALL — SO0.426.1426 S. TRASH CHUTE: FRANKLIN MACHINE PRODUCT — S.S. MODEL *111 -1128. FOR PRODUCT LT —I. WALL SCONCE: SEA GULL LI&HTIN6 #8440 -44 "OUTDOOR WALL LANTERN ", WEATHERED COPPER FINISH SOLID BRASS / CLEAR SEEDED GLASS, 6O —WATT ORDERIN6 GALL — 800.251"1'13i FROSTED A —LAMP. . WALL MOUNTED DOOR STOP: "IVES" 4:401 i S3212 S.S. (AT HANDLE HEIGHT). FOR LT -2. REPLACE EXISTING 2x4 LIGHT FIXTURES or "A6E0" EXISTING CAN LI&HT FIXTURES PRODUCT SEE LOCAL HOME DEPOT STORE. WITH LITHONIA *LUP /GB—I w/ BLACK TRIM RING, 15 -WATT — R LAMP. 10. CUSTOM MIRROR, SUPPLY BY OWNER — INSTALLED BY G.C. 11. SINKS: GORIAN UNDER MOUNT — WHITE FAUCET 4 HARDWARE: REUSE EXISTING STAIN 12. CHAIR -RAIL FINISH: REFER TO ROOM FINISH SCHEDULE 5 -4 ON SHEET A5.3. 13. WATER CLOSETS AND URINALS TO BE REPLACED LIKE FOR LIKE. (FIXTURES ONLY) 14. NOT IN USE 15. SEE KEY NOTE *I5 ON SHEET A2.I FOR RESTROOM DOORS. 16. STAIN AND SEAL. EXISTING CONCRETE \9__.[- c) REVIEWED FOR, CODE COMPLIANCE APPROVED JAN 2 6 2012 City oribliwIla BUILDING DIVISION UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Anthitect is not permitted MERRICK LENTZ ARCHITECT ARCHITECTURE - PLANNING 1800136th Place NE • Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com stamp consultant project name 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 ... set drawing title RESTROOM PLAN, NOTES crtroFECEI7uu► JAN -0 4 2012 PERMIT CENTER drawn by MSC checked by issued date description A5.4 LIGHTING FIXTURES v FLUORESCENT FLUORESCENT W /BATTERY BACKUP 2X4 FLUORESCENT FLUORESCENT STRIP 0 ❑ H.I.D., FLUORESCENT OR INCANDESCENT COI-❑ WALL MOUNTED v v TRACK LIGHTING 0-o POLE MOUNTED FIXTURE BATTERY POWERED EMERGENCY ID EXIT SIGN SWITCHING So SINGLE POLE S 3 THREEWAY $4 FOURWAY Si_ LOCKING SD DIMMER SM ST Sv MANUAL MOTOR STARTER WITH THERMAL OVERLOADS TIMER PILOT LIGHT VARIABLE SPEED FAN CONTROLLER SWITCH WITH LED PILOT LIGHT OCCUPANCY SENSOR ,b,c) DENOTES SWITCH LEGS POWER DEVICES = PANELBOARD FLUSH MOUNTED --- PANELBOARD - SURFACE MOUNTED 0 250 LOW VOLTAGE TRANSFORMER 250 '(WATTAGE PER CIRCUIT) ,0. FLOORBOX WITH DUPLEX RECEPTACLE MOTOR CONNECTION. (NUMBER = HORSEPOWER) D DISCONNECT SWITCH 0' DISCONNECT SWITCH - FUSED Z COMBINATION STARTER /DISCONNECT ▪ MAGNETIC STARTER ® EQUIPMENT CONNECTION © SPECIAL RECEPTACLE CB CLOCKBOX RECEPTACLE. eg ID DUPLEX RECEPTACLE QUADRAPLEX RECEPTACLE PUSHBUTTON CONTROLLER O JUNCTION BOX RACEWAY FIRE ALARM 01 MINI HORN /STROBE COMBINATION a MINI HORN © MANUAL PULL STATION SO SMOKE DETECTOR SMOKE DETECTOR WITH STROBE HEAT DETECTOR MAGNETIC DOOR HOLD OPEN FLOW SWITCH TAMPER SWITCH LOW PRESSURE SWITCH RELAY DUCT SMOKE DETECTOR CONNECTION (REMOTE TEST, W/ LED) EO 10" EXTERIOR BELL - WEATHER PROOF KNOX BOX STROBE ONLY TELEPHONE - DATA HOMERUN TO PANEL DATA OUTLET - (2) RJ45 JACKS P1 -5 (INDICATES PANEL AND CIRCUIT NUMBER) 1 AND 2 -4PR CATEGORY 5 CABLES -111 -- NUMBER OF CONDUCTORS 1O (WIRE GAUGE OTHER THAN AWG #12) nl' PHASE CONDUCTOR I NEUTRAL CONDUCTOR ■�GROUND CONDUCTOR TELEPHONE OUTLET PAINTED 3/4" PLYWOOD BACKBOARD CONTRACTOR IS TO BRING UP ANY DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN, BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM, AND WHICH AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT. AFTER AWARDING THE CONTRACT, ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH AFOREMENTIONED DISCREPANCY ITEMS AT NO ADDITIONAL COST TO THE OWNER. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO DETERMINE THE EXACT IMPACT OF THE RETROFIT TO THE ELECTRICAL SYSTEM AND SHALL INCLUDE IN HIS BID ALL THE WORK WHICH MIGHT NOT BE SPECIFICALLY MENTIONED BUT ARE REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM READY FOR OWNER'S BENEFICIAL USE. ELECTRICAL GENERAL NOTES: 1) ALL RECEPTACLES AND SWITCHES SHALL BE FLUSH MOUNTED FOR ALL AREAS. U.O.N. 2) THE ELECTRICAL DRAWINGS ARE GENERALLY DIAGRAMMATIC. THE ELECTRICAL INSTALLATION SHALL BE COORDINATED WITH ALL OTHER TRADES SO THAT INTERFERENCES BETWEEN THE ELECTRICAL INSTALLATION AND ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND EQUIPMENT INSTALLATION WILL BE AVOIDED. 3) REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE RELATED PARTITIONS, CABINET AND CASE WORK AND BUILT -IN DETAILS. 4) ALL WIRING TO BE SIZE #12 AWG UNLESS NOTED OTHERWISE. 5) CONTRACTOR SHALL PROVIDE ALL DISCONNECTS TO MEET LOCAL CODES. 6) CONTRACTOR SHALL VERIFY ALL DOOR SWINGS BEFORE INSTALLING LIGHT SWITCHES. ALL LIGHT SWITCHES TO BE INSTALLED ON STRIKE SIDE OF DOOR UNLESS SPECIFICALLY NOTED OTHERWISE. 7) ALL FINAL CONNECTIONS SHOWN ON THE DRAWINGS ARE ACTUAL REQUIREMENTS OF THE EQUIPMENT AND ARE SHOWN IN THEIR APPROXIMATE LOCATION. 8) ALL MOTOR STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR FURNISHING THE EQUIPMENT AND INSTALLED, WIRED AND CONNECTED BY ELECTRICAL CONTRACTOR. AUDIO/VISUAL INDICATOR SHALL BE INSTALLED ABOVE THE FIRE ALARM PULL STATION WHERE APPLICABLE AT APPROXIMATELY 6" BELOW CEILING OR +80" A.F.F. WHICHEVER IS LOWER. 10) ALL BATTERY BACKUP, EMERGENCY LIGHTING FIXTURES SHALL BE CONNECTED TO THE SAME CIRCUIT SERVING LIGHTING IN THAT AREA PRIOR TO ANY SWITCHING. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHERPROOF AND RAIN TIGHT. COORDINATE ALL LIGHTING WITH MECHANICAL AND PLUMBING EQUIPMENT. CONTRACTOR TO VERIFY THAT EQUIPMENT WITH CIRCUIT BREAKERS AS LOCAL DISCONNECT MEANS IS HACR RATED. IF NOT, PROVIDE DISCONNECT SWITCH PER N.E.C. 9) 14) MOUNTING HEIGHT OF ALL DEVICES SHALL CONFORM WITH 2008 N.E.C., STATE ELECTRICAL CODE, LOCAL CODES AND ADA. UNLESS OTHERWISE INDICATED ON THE DRAWINGS. - RECEPTACLES: 15 "; 48" AFF TO CL - SWITCHES: 48" AFF TO CL 15) REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLY DESIGN NUMBERS. COORDINATE ALL DESIGN WORK WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. 16) FINAL DETERMINATION OF FIRE DAMPERS AND OTHER FIRE STOPPING REQUIREMENTS SHALL BE BASED ON LOCAL CODE REQUIREMENTS. 17) ELECTRICAL SYSTEM EQUIPMENT AND COMPONENTS SHALL BE U.L LISTED, AND BE IN COMPLIANCE WITH THE REGULATIONS OF THE STATE AND LOCAL ENFORCING AGENCIES. 18) THE ELECTRICAL CONTRACTOR SHALL REFER TO AND COORDINATE THE LOCATION OF ALL AREA/ OCCUPANCY SEPARATION WALLS WITH THE ARCHITECTURAL DRAWINGS AND DETAILS. 19) ALL CONDUIT, ETC. PENETRATIONS THROUGH THE BUILDING SHALL BE FIRE /SMOKE STOPPED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH - PENETRATION FIRE STOPS SYSTEM VOLUME #2 OR SHALL BE INSTALLED IN STRICT ACCORDANCE PER THE MANUFACTURERS U.L. LISTINGS (3M -0R EQUAL). COORDINATE WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 20) ALL ELECTRICAL WORK SHALL CONFORM TO U.L. STANDARDS, 2008 N.E.C., N.F.P.A. AND ALL OTHER CODES OF JURISDICTION WHICH ARE APPLICABLE TO THIS ELECTRICAL INSTALLATION. 21) WHERE REMODELING /DEMO WORK DISRUPTS CONTINUITY OF EXISTING CONDUITS OR CIRCUITS, PROVIDE CONDUIT /WIRE /J- BOXES, ETC TO RESTORE /MAINTAIN CONTINUITY. 22) EC SHALL REFER TO ARCHITECTURAL DRAWINGS FOR WALL DEMOLITION AND REMOVE ALL ELECTRICAL DEVICES, LIGHTS, ETC. AND ASSOCIATED EQUIPMENT. EC SHALL REWIRE CIRCUITS AS NECESSARY TO MAINTAIN CIRCUIT CONTINUITY TO DOWNSTREAM DEVICES. NOTE: NO LOAD INCREASE DUE TO LIGHTING REVISIONS. OVERALL REDUCTION OF 450 WATTS /1.25 AMPS. EXISTING LIGHTING CABINET LOCATION: MAIN ELECTRICAL ROOM PANEL D LOAD DISTRIBUTION REC LTG EQP HTG 0.48 0.48 0.56 0.60 0.50 MEIN MI 1.05 1.44 0.15 MEN MN MIN MOM MIN MINNIE MINIM 0.66 FEED FROM: PANEL L CKT 3 5 7 9 11 13 15 17 DESCRIPTION. CHANDELIER - SOUTH CHANDELIER - NORTH WAITING/ENTRY AREA BAR/LOUNGE CORRIDORS BAR/LOUNGE TABLES/BOOTHS BAR - PERIM ETER CANS BAR - CENTRAL PENDANTS BAR - M ONOPOINTS (LIQUOR DISPLAY) SPACE FEEDER: 60 AMP 3P4W + GND AM P POLE 20 20 20 20 20 20 20 20 Q MI MI MN MIN MI MINN MI =NM MI MI NEM EMI LOAD kVA 0.48 0.48 0.56 0.60 0.50 1.05 1.44 0.15 AM P: VOLTS: PHASE: WIRE BUS TYPE A.I.C.: 125 208/120 3 4 CU 10K M.LO.: XXX MAIN CB: FLUSR SURFACE: GND. BAR: XXX ISO GND: 200 %NEU: FEED THRU: DBLLUG: TOP FEED: BTM FEED: I MI NM OM 0.60 5 ��� 0.55 ®_� MINI 0.40 ��� 0.54 MI 1=1 En EMI INN NM NMI MIN A NEM MIN EN 2 4 6 8 10 12 14 16 18 DINING TABLES/BOOTHS - NORTH PERIM ETER WALLWASHERS - PERIM ITER DINING CORRIDORS DINING TAB LES /BOOTHS - SOUTH PERIM ETER DINING BOOTHS- SOUTH DINING BOOTHS- NORTH SPACE SPACE 4.2 if 4I 4P Q 3.1 3.5 20 20 20 20 20 20 20 0.66 1.44 MI ME= 0 MN - 0.60 0.54 0.55 0.40 Manufacturer /Type: Circuit Breaker Type: Remarks: PANEL T.C.L. LOAD (kVA) REC LTG EQP HTG KIT 10.8 TOTAL 10.8 FEEDER T.C.L. LOAD (kVA) REC LTG EQP HTG KIT 10.8 TOTAL 10.8 FEEDER DEMAND kVA 13.5 AM PERES 37.4 PHASE A : PHASE B: PHASE C: 4.2 3.1 3.5 kVA kVA kVA RECEPTACLES (1ST 10KVA): RECEPTACLES OVER 10KVA: LIGHTING: EQUIPM ENT: HEATING: COM M ERCIAL KITCHEN: 25 %OF LARGEST M OTOR: CONNECTED: CONNECTED: kVA 100% kVA 50% 10.8 kVA 125% kVA 100% kVA 100% kVA 65% kVA 25% 10.8 kVA DEMAND: 29.9 Amps DEMAND: kVA kVA 13.5 kVA kVA kVA kVA kVA 13.5 kVA 37.4 Amperes UTILITY TRANSFORMER 208Y/120V 30, 4W ■ SERVICE POINT METER/ BASE CURRENT TRANSFORMER ENCLOSURE (1) 1 1/4" C., (4) #4 CU THWN (1) 1 1/2" C., (4) #1 CU THWN (1) 2" C., (4) #3/0 CU THWN "P\2- oc)5 PANEL 'MDP' 800A MAIN BREAKER 208Y/120V 30, 4W 200A 3P 200A 3P 200A 3P 125A 3P 70A 3P 100A 3P 400A 3P 800A 3P n 0 o 0 0 EXST'G 2/0 CU PANEL P (HVAC) 400A MAIN LUG 208Y/120V 30, 4W - (1) 1 ` 1/2" C., (4) #2 CU THWN (2) 2" C., (4) #3/0 CU THWN (2) 3 1/2 CONDUITS WITH (4) 600kCMIL CU THWN EACH. RISER DIAGRAM CHEF ISLAND 125A MAIN LUG 208Y/120V 30, 4W D SHWASHER BOOSTER HTR 100A 3P DISC 200A 3P DISC PANEL 'K1' 225A MAIN LUG 208Y/120V 30, 4W 100A 3P -0 0 PANEL 'K2' 225A MAIN LUG 208Y/120V 30, 4W ALL EQUIPMENT, PANELS, FEEDERS, TRANSFORMERS, ETC., SHOWN ARE EXISTING AND SHOWN FOR REFERENCE ONLY (1) 1 1/2" C., (4) #2 CU THWN PANEL 'S' 225A MAIN LUG 208Y/120V 30, 4W 60A 3P PANEL 'L' 225A MAIN LUG 208Y/120V 30, 4W (1) 1" C., (4) #6 CU THWN PANEL 'D' DIMMING CABINET W /BRANCH BREAKERS UNPUBLISHED WORK © 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted H RRICK LENTZ ARCHITECT ARCR1TECTUR•E PLANNING 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t.425.747.3177 f.425.747.7149 www.mlarch.com consultant project name OUTBACK STEAKHOUSE® 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 PERMIT SET crrvo drawing title ELECTRICAL NOTES, SCHEDULES, LEGENDS RECEIVED_ JAN A 4 2012 PERMIT CENTER drawn by GLN checked by 2011 08 16 PERMIT SET issued date description E1.0 ABOSSEIN JN# 211068 Abossein Engineering, L.L.C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Mail: cselvice@abossein.cam www.abossein.com project name OUTBACK STEAKHOUSE® 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 PERMIT SET crrvo drawing title ELECTRICAL NOTES, SCHEDULES, LEGENDS RECEIVED_ JAN A 4 2012 PERMIT CENTER drawn by GLN checked by 2011 08 16 PERMIT SET issued date description E1.0 ABOSSEIN JN# 211068 Interior Lighting Summary 2009 Washington State Energy Code Compliance Fomis fo r Nonresidential and M ultifamily Residential LTG -INT Revised December 2013 Project Info Project Address OUTBACK RESTAURANT Date 8/16/2011 so U T H C E N T E R PARKWAY For Building Department Use TUKW 3LA W A Applicant Name: Applicant Address: Applicant Phone: Project Description 4 KB 1RECESSED CAN ,50W MAXMR16 ■ New Building © Addition D Alteration Q Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option KC 1RECESSED CAN ,50W M AX M R16 ® Systems Analysis ® Clear spaces clearly on plans.) 11 Prescriptive Q Lighting Power Allowance (See Qualification Checklist ( over). Indicate Prescriptive & LPA ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA otal Allow ed Watts 2 Alteration Exceptions (check appropriate box - sec. 1132.3) changed M No changes are being made to the lighting an d space use not Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allow ed x Area WATTAGE KA KA -1 RELOCATED WALLWASH FIXTURE. CIRCUIT AS SHOWN BLAIR COMPANIES: CUSTOM PART #OSH_EL 00002 LED LIGHT BAR WITH MOUNTING CUPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (2)5' -8" LENGTHS, (2)80W MEANWELL POWER SUPPLIES BLAIR COMPANIES: CUSTOM PART #OSH_EL_00001 LED LIGHT BAR WITH MOUNTING CLIPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (4)7' -6" LENGTHS, (2)80W MEANWELL POWER SUPPLIES 160 160 4 KB 1RECESSED CAN ,50W MAXMR16 4 50.0 200 KC-1 KC-4 KC 1RECESSED CAN ,50W M AX M R16 31 50 1550 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA otal Allow ed Watts 2 Proposed Lighting Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed WATTAGE KA KA -1 RELOCATED WALLWASH FIXTURE. CIRCUIT AS SHOWN BLAIR COMPANIES: CUSTOM PART #OSH_EL 00002 LED LIGHT BAR WITH MOUNTING CUPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (2)5' -8" LENGTHS, (2)80W MEANWELL POWER SUPPLIES BLAIR COMPANIES: CUSTOM PART #OSH_EL_00001 LED LIGHT BAR WITH MOUNTING CLIPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (4)7' -6" LENGTHS, (2)80W MEANWELL POWER SUPPLIES 160 160 4 KB 1RECESSED CAN ,50W MAXMR16 4 50.0 200 KC-1 KC-4 KC 1RECESSED CAN ,50W M AX M R16 31 50 1550 ;1; 550A,B ,C - CUSTOM PENDANTS (8) 60W MAX NCAND 2 480.0 960 T1 -LOW VOLTAGE TRACK (WATTAGE =XFMR S3ZE) 2 300 600 0 KF- 1RECESSED CAN ,50W MAXMR16 19 50 950 EXISTING TABLE PENDANT. G.C. TO REPLACE SHADE. SEE SHEET A4.1 KD -14 TRACK HEAD 50W MAXMR16 3 50 150 60 LT -3 CUSTOM .BAR PENDANT 60W MAX NCAND 24 60 1440 60 T1 T2 T1- TRACK -CON -TECH MLT-4-B. (4' 4)") TRACK T1- TRACK -CON -TECH MLT -6-B. (6' -01 TRACK DETERMINED BY XFMR WATTAGE EXISTING EXTERIOR WALL SCONCE; G.C. TO REPLACE WHITE SHADE WITH NEW BRONZE SHADE PROVIDED BY REXEL. REMOVED: PENDANT 100W MAXA39 33 -100 -3300 RECESSED CAN 75W MAX PAR 30 32 -75 -2400 CE3LNG FAN (2) 60W MAX 5 -120 -600 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts -450 LIGHT FIXTURE SCHEDULE KEY NOTES FIXTURE SYMBOL DESCRIPTION /COMMENTS WATTAGE KA KA -1 RELOCATED WALLWASH FIXTURE. CIRCUIT AS SHOWN BLAIR COMPANIES: CUSTOM PART #OSH_EL 00002 LED LIGHT BAR WITH MOUNTING CUPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (2)5' -8" LENGTHS, (2)80W MEANWELL POWER SUPPLIES BLAIR COMPANIES: CUSTOM PART #OSH_EL_00001 LED LIGHT BAR WITH MOUNTING CLIPS AND DIMMER. 80 LUMEN/W, 4.5W, 3500K, WARM WHITE, 12VDC VOLTAGE, 110 DEGREE BEAM ANGLE, ALUMINUM EXTRUSION HOUSING. POWER SUPPLY UL LISTED CLASS 2 12VDC TRANSFORMER. TYPICAL (4)7' -6" LENGTHS, (2)80W MEANWELL POWER SUPPLIES 160 160 4 KB -1 KB -2 KB -3 KB-4 O-� CON -TECH LVR 316 -CTR 325-B, SYL 50MR16 /SP10 /C (EXT 12V). USE WITH SOLITE MR -16 LENS SAME AS KB -1 EXCEPT FOR LOW IRON MR -16 FROSTED LENS SAME AS KB-1 EXCEPT WITH LINEAR SPREAD LENS. ROTATE LENS VERTICALLY TO PROTECT LIGHT HORIZONTALLY. INSTALL LENS WITH TEXTURE EXPOSED ON OUTSIDE OF FIXTURE SAME AS KB -1 EXCEPT FOR HEXAGON LOUVER 50 KC-1 KC-4 0 CON -TECH LVR 316 WITH CTR302 -B-BLK TRIM, SYL 50MR16 /SP10 /C (EXT 12V). USE WITH SOLITE LENS SAME AS KC -1 EXCEPT FOR HEXAGON LOUVER 50 KD KD-1 KD -2 KD-4 KD-M ;1; CON -TECH MCT- 2116 -(B), SYL 50MR16 /SP10 /C (EXT 12V) WITH CLEAR LENS SAME AS KD EXCEPT FOR SOLITE LENS SAME AS KD EXCEPT FOR LINEAR SPREAD LENS. ROTATE LENS VERTICALLY TO PROJECT LIGHT HORIZONTALLY. INSTALL LENS WITH TEXTURE EXPOSED ON OUTSIDE OF FIXTURE SAME AS KD -2 EXCEPT FOR SOLITE LENDS AND THE FOLLOWING ADJUSTMENTS: (3) LA50 -B ADJUSTABLE MOUNT (3) STEM BARS (12 ", 24" AND 36" CUT TO LENGTHS- F.V.) (1) LAID -B CONNECTOR (8) EGGYOLK LIGHTS SUSPEND FROM CEILING ABOVE CON -TECH MONO -POINT ADAPTOR, MLA- 19 -(B). SAME AS KD EXCEPT WITH LINEAR SPREAD LENS 50 ® KE LED WAVES: MODEL LW20_2100 A22_E3G W2700K - POWER SUPPLY LW20- 1100- A- DC81514 (NON- DIMMING MODULE) LENGTH T.B.D. - LINEAR LED SURFACE MOUNTED ADHESIVE MULTI -LAMP LED TAPE WITH REMOTE DRIVERS. 120 DEGREE BEAM SPREAD; LAMPS 1/2" O.C., WET LISTED. OSI SUPPLIED /CONTRACTOR INSTALLED 50 13 KF -1 0 (DOWN LIGHT) CON -TECH LVR 316 WITH CTR305 -B -BLK TRIM - SYL 50MR16 /SP10 /C(EXT 12V). USE WITH SOLITE LENS 50 EXISTING TABLE PENDANT. G.C. TO REPLACE SHADE. SEE SHEET A4.1 50 LT2.1A LT2.1B LT2.1C PENDANT IS INTEGRATED WITH CEILING FEATURE. LAMP: EDISON SQUIRREL CAGE PENDANT IS INTEGRATED WITH CEILING FEATURE. LAMP: EDISON HAIRPIN 40W PENDANT IS INTEGRATED WITH CEILING FEATURE. LAMP: EDISON QUAD LOOP 60 TT LT -3 PENDANT IS INTEGRATED WITH CEILING PANEL. A, B, AND C DESIGNATE MOUNTING HEIGHT PRESET BY NAUTICAL FURNISHINGS, INC. LAMP: SATCO CROWN CHROME A6019 60 T1 T2 T1- TRACK -CON -TECH MLT-4-B. (4' 4)") TRACK T1- TRACK -CON -TECH MLT -6-B. (6' -01 TRACK DETERMINED BY XFMR WATTAGE EXISTING EXTERIOR WALL SCONCE; G.C. TO REPLACE WHITE SHADE WITH NEW BRONZE SHADE PROVIDED BY REXEL. SECURED STORAGE 1 105 RESTROOM MENS J LT2 STORAGE RESTROOM WOMENS A 0 DI C (PNL 0) (E € fl(E) i � € tl f I E E 1111111111 c KC -1 1 mist irL1•1 errn rrrrr�rrmsurxaw iiLLL KA.. —...1- (E) (E) /CUSTOMI WAI TIN AREA KITCHEN iri�ii7i. '"� M .-�L ,II�� , 1rL1 •' �a w � j €E,:'7:T':xjfi ?if €u.n3j' 1; €1 €9t 'Flt' €:I#€ cl nE�€ ilU ty.`ip "`Ill. �# d3 k`' �?,! t , I ��L1.'E�Illllltllllll'E _ -• .lam ,ice X1111. t��l��R►1�ri�lllA►liiil `I " RPRECIDIREI 1!. .1. FREEZ DISHWASHER i11iR.fil�lt • • f�faR:f f��iYwff�f� "- Itafif�f�it� iff OFFICE MECHANICAL ROOM ELECTRICAL ROOM IIaiaau�ii i ' I Q KEY NOTES xi L.L.C. amia. EXISTING EGRESS/EXIT FIXTURE. MAINTAIN EXISTING CIRCUITING. 2 RELOCATED WALLWASH FIXTURE. CIRCUIT AS SHOWN ii PROVIDE SURFACE MOUNTED DUPLEX RECEPTACLE AT FLOOR OF LOUVER CABINET FOR LED KA -1 4 KE LED SHELF FIXTURES AT LIQUOR STEPS AND BAR DISPLAY CABINETS. COORD W /G.C. FOR EXACT LOCATIONS/REVS 5 6 7 8 s 10 11 12 13 MO iri�ii7i. '"� M .-�L ,II�� , 1rL1 •' �a w � j €E,:'7:T':xjfi ?if €u.n3j' 1; €1 €9t 'Flt' €:I#€ cl nE�€ ilU ty.`ip "`Ill. �# d3 k`' �?,! t , I ��L1.'E�Illllltllllll'E _ -• .lam ,ice X1111. t��l��R►1�ri�lllA►liiil `I " RPRECIDIREI 1!. .1. FREEZ DISHWASHER i11iR.fil�lt • • f�faR:f f��iYwff�f� "- Itafif�f�it� iff OFFICE MECHANICAL ROOM ELECTRICAL ROOM IIaiaau�ii i ' I Q KEY NOTES Engineering, L.L.C. 1 EXISTING EGRESS/EXIT FIXTURE. MAINTAIN EXISTING CIRCUITING. 2 RELOCATED WALLWASH FIXTURE. CIRCUIT AS SHOWN 3 PROVIDE SURFACE MOUNTED DUPLEX RECEPTACLE AT FLOOR OF LOUVER CABINET FOR LED KA -1 4 KE LED SHELF FIXTURES AT LIQUOR STEPS AND BAR DISPLAY CABINETS. COORD W /G.C. FOR EXACT LOCATIONS/REVS 5 6 7 8 s 10 11 12 13 SEE ALSO SHEET A4.1 FOR ADDITIONAL LIGHTING NOTES, REQUIREMENTS, DETAILS, ETC. 1 L_ FLOOR PLAN SCALE: r = (E) "Not A� UNPUBLISHED WORK 0 2011 MERRICK LENTZ ARCHITECT Unauthorized use or reproduction of these drawings or any part herein without the permission of Merrick Lentz Architect is not permitted MERRIC LENT/ ARCHITECT ARCHITECTURE - PLANNING. 1800 136th Place NE - Suite 100 Bellevue, WA 98005 t425.747.3177 f.425.747.7149 www.mlarch.com consultant project name OUTBACK STEAKHOUSE® 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 PERMIT SET drawing title LIGHTING PLAN RECEI CITY OF TU V D LA JAN 0 2012 PERMIT CENTER drawn by GLN checked by 2011 08 16 PERMIT SET issued date description E3.0 ABOSSEIN JN j 211068 Abossein Engineering, L.L.C. MECHANICAL — ELECTRICAL CIVIL — LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Mail: cservice@abossein.com www.abossein.com project name OUTBACK STEAKHOUSE® 16510 SOUTHCENTER PKWY TUKWILA, WA 98188 PERMIT SET drawing title LIGHTING PLAN RECEI CITY OF TU V D LA JAN 0 2012 PERMIT CENTER drawn by GLN checked by 2011 08 16 PERMIT SET issued date description E3.0 ABOSSEIN JN j 211068