HomeMy WebLinkAboutPermit D12-025 - BARTON RESIDENCE - UGPRADESBARYON RESIDENCE
12223 48 AV S
D12 -025
City okukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 0179001300
Address: 12223 48 AV S TUKW
Suite No:
Project Name: BARTON RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D12-025
Issue Date: 03/20/2012
Permit Expires On: 09/16/2012
Owner:
Name: BARTON SANDRA S
Address: 12223 48TH AVE S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $25,087.00 Fees Collected: $993.76
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -025 Printed: 03 -20 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
s •
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: r)-Cl t
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name:
4,77
Zee Goer r y
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date:
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
012 -025 Printed: 03 -20 -2012
this requirement.
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall m the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -025 Printed: 03 -20 -2012
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http../Iwww.ci.tukwila.iva.us
Building Permi £ No. b U-r- O
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 12223 48th Avenue S.
Tenant Name: Sandra S. Barton
Property Owners Name: Sandra S. Barton
Mailing Address: 12223 48th Avenue S.
King Co Assessor's Tax No.: 0179001300
Suite Number: Floor:
New Tenant: ❑ Yes ® ..No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
city
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Contact Person: Melody Leung
or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
H:Wpphcations\Porms- Apphcattons On Line\2009 Apphcattons\l -2009 - Permit Applicanon.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFO
ION — 206 -431 -3670
Valuation of Project (contractor's bid price): $ 25,087 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No if "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Applications,Forms- Applications On Line,2009 Applications`.I -2009 - Permit Application.doc
Revised: 1.2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
750
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No if "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Applications,Forms- Applications On Line,2009 Applications`.I -2009 - Permit Application.doc
Revised: 1.2009
bh
Page 2 of 6
• •
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Date:
(r- F-e.(9 Zo tZ
Day Telephone: !— P (0 24 - �►
Mailing Address:
City
State
Zip
Date Application Accepted: Date Application Expires:
Staff Initials:
H:'Applicat ions \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPINOERMIT INFORMATION - 206 -431 7
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:'Applications'• Forms - Applications On- tinc•2009 Applicatiotu'.1 -2009 Permit Application.doc
Revucd, 1 -2009
bh
Page 5 of 6
CA, of Tukwila,
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -00879
Initials: WER
Payment Date: 03/01/2012
User ID: 1655 Total Payment: 17,659.72
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED
SET TRANSACTIONS:
Set Member Amount
D12 -025
D12 -026
D12 -027
D12 -028
D12 -029
D12 -030
D12 -031
D12 -032
D12 -033
D12 -034
D12 -035
D12 -036
D12 -037
D12 -038
D12 -039
TOTAL:
993.76
1,313.36
1,313.36
1,042.93
993.76
1,239.61
1,411.70
993.76
1,387.12
1,165.85
811.18
905.73
1,460.87
1,190.44
1,436.29
993.76
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 17,659.72
TOTAL: 17, 659.72
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 10,661.95
000.345.830 6,930.27
640.237.114 67.50
TOTAL: 17, 659.72
INSPECTION RECORD
Retain a copy with permit
..7/
INSPECTION NO. PERMIT NO._
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 vz, (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
6 A 71_-'-00 `- y,y' -,
Type of Inspection: q
1 ,'-1.\ L. _- C.:7('CL%.,'
• .•;
Address:
' ' •..::) E AU r;
Date Called: .
'Li-) cFE' '• ,
Special Instructions:
/
/
/
Date Wanted:.
1 i iri 1; 2
,a.m.
p.m.
Requestdr:
Phone No:
'_-`5 ` 1 -. . • 7 `i `' ?. f
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspectdr:
!I
F-7 REINSPECTION FEE EQUIRED. prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
r
i
Date: / t �'
1, II
[ ssu?atioio Certificate / Blower Door Test Form
III 11a (�1
Batts and Blankets
When Installed in accordance with the manufacturer's
recommendations. Knauf batts and blankets will provide
the full R- value.
insular,or. Northwest LLC
ktikatetu
CITY OFTtH<II of n
NOV 1 4 2012
PERMIT CENTER
Thermal Performance (Attic Application) ne required number o;
The stated dnermal resistance (R- value) is provioed by installing in accordance with the manufactuers instructions,
bags per 1,000 sq.R of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at
least the minimum thickness wall result in lower insulation R- value.
R- Value` Minimum Thickness R- Value' 1Ba s /1,000 sy. ft I Maximum Covera a Minimum Wei•fit Minimum Thickness
y
cover more roan: insulation should not be not be less than.:
75 Obtain An insulation Installed insulation should I o Obtain an insulation The number of ontents of this Sag should not The weight/SF of installed Installed insulation should
resistance (R- Value) of: not be less than,: resistance (R- Vaiue) or: bags /1 000 :;F of net I less than.
area should not be 19.75"
R -60 I 31.7 31.5 SF 1 .952 LOS I 16.75"
R-38HD I 10.25" I 38.7 SF I
.774 LBS
12.00" I R-49 I 25.8 .663 LBS II 14 -75"
R-38 45.3 SF
R-30HD I 8.25" R-44 I 22.1 52.7 SF I .569 LBS I 13.00"
10.00" R -38 I 19.0 .431 LBS I 10 -25"
R -2 I 14.4 I 697 SF 9.00"
R -26 I 9.00" R -30 I 12 4 I 80.9 SF .371 LBS
R -22 I 6.50" R -26 I 95.8 SF .313 LBS 7.75"
5.50" R -22 I 10.4 .268 LBS I 6.75"
R-21HD I 8.9 1 111.8 SF
R -19 I 6.25 "" R-19 I 4.75" i
164.3 SF .183 LBS
3.50" R-13 I 6 -1 I
.152 LBS I 4.00
R-15HD 1 5.1 I 197.6 SF requirements R -13 I 3.50" R -11 I
3.50" Bag Weight Federal -Nominal 30 ibs., Minimum 29 : T Type sirs B. R -Values ues are de ern' ed performance
n accordance withf C 687 and C 51 . " "R" means Type I, and
R -11 cancelled Federal Saecifica5on Fitt -I- :0308, Y^
R -8 2.50 resistance tc heat flow. The higher the P.-value. the greater the insulation power. To get the marked R- value, it is eseential `,'nat the
R -er in a 55" cavity. Co -521F to ASTM C665 and insulation be installed properly If you do it yourself, get instructions and follow them carefully.
Federal Specification HI- I -521F.
To achieve labeled R- value, this product must be applied with a pneumatic blowing machne and a
corrugated hose with a minimum 25" interval corrugation, a minimum length cf 150 ft. and a a,arreter
of at least 3 ". Coils In the hose should not be less than 36" in diameter. Acceptable material feed
rate is 5-35 lbs. /minute. Recommended feed rate is 15- 25Ibs. /mmu52
Builders Insulation Statement
Batts and/or blankets have been installed in conformance with the above recommenda30! 5 to
provide a thermal resistance of...
•Attic Area 1'R.
(Sloped Ceilings IR-
Walls I R-
Floors (over an unheated crawl space) 1R-
Completed as of:
Site Address:
Home Builder
Signature:
Home Builder
Address:
R -Value
2009 W./i1SEC Residential Energy Compliance
Certificate - Building Air Leakage
Buildino & Test Condition Comments
Date:
Time:
Indoor Temperature:
Outdoc" Termperature:
Floor Area (fb)
I Standard
R-49
R -38
1 R -21
R -30
'% 5 %2
/4Z223-4'.0exMe 5o•
rel&zi% 14 o, l N
(Insulation
'Contractor: Insulation Northwest LLC
P.O. Box 732069
Puyallup, WA 98373
Phone: (253) 846 -0121
Fax: (253) 846-8096
Buildin3 Air Leaka,e Target: SLA Less than 0.00030
Test #1
Depress ._ Press ._
Pretest Baseline Pressure: (Pe)
Bldg Press. (Pa) Flow Ring
Fan Press. I Flow (cfm)
(Pa)
Post -Test Pressure: - (Pa)
Fan Model /SN:
Results:
SLA (Specific Leakage Area):
Test #2
Depress . . Press .�
Pretest Baseline Pressure: (Pa)
Sidg Press. (Pa(\ Flow Ring Fan Press. (Pa)
. 1
Post -Test Pressure: . (Pa)
Fan Model /SN:
Results:
SLA (Specific Leakage Area):
Flow (cfm)
Affidavit: certify that this Specific Leakage Area is accurate 2no ceter nineo us:rg B',cwer Door Test Standard 502.4.5 Building Al Leakage Testing.
harne
Technician Signature
1
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
October 1, 2012
Timothy J. Fenlason
S.M. Stemper Architects
4000 Delridge Wy SW, Ste 200
Seattle, WA 98106
RE: Request for Extensions
KCIA RANRIP Permits D12 -025 through D12 -039
Dear Mr. Fenlason,
This letter is in response to your written request for an extension to Permit Numbers DI2 -025
through DI2 -039. The Building Official has reviewed your letter and considered your request to
extend the above referenced permits. The City of Tukwila Building Division will be extending
your permits an additional 60days from the date of expiration, November 15, 2012.
If you should have any questions, please contact our office at (206) 431 -3670.
Jen 'fer Mar•
e it echn
File: Permit No. DI2 -025 through D12 -039
W:\Permit Center \Extension Letters \Pennits\2012 \D12 -025 Permit Extension.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
•
S.M. STEMPER ARCHITECTS
A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y
13 September 2012
Bill Rambo, Permit Technician
City ofTukwila, Department of Community Development
6300 Southcenter Boulevard, Suite 4100
Tukwila, WA 98188
RE: Bid Package M -27 Permits
Dear Mr. Rambo,
This letter serves as written request to extend the perm its listed below, which are part of King County
International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RAN RIP).
Permit Address Permit Number Permit Address Permit Number
12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033
11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034
5003 S. 1 13th St. D12 — 027 12222 47th Ave S. D12 — 035
12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036
5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12 — 037
11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038
11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039
12203 47th Ave S. D12 — 032
Permits for these properties were requested by our office as the homeowner's representative since this is
a public project and is bid in accordance with grant requirements.
A contract has been awarded and construction is in progress, but will not be complete by the end date of
the original permits. Extension on all properties should be made for an additional 60 days.
If you need further clarification or have questions, please contact me at 206 -721 -0061 or
tfenlason@onespayne.com.
a ,
Aei
llai
die
ci/7400/Z
Timothy J. Fenlason
Project Manager
The Jones Payne Group, Inc.
CITY OF TUKWILA
SP 13 20121
PERMIT CENTER
euP oi Iiull2
4000 DELRIDGE WAY SW . SUITE 200 . SEATTLE, WA 98106 • 206/ 624 -2777 . FAX 206/ 624-2973
k- 14\ 'lc 11,
10 -01 -2012
City of f 'Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -025
BARTON RESIDENCE
12223 48 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 11/15 /2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 11/15/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
r Marshall
Technician
File: Permit File No. D12 -025
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665
08 -01 -2012
City of Tukwila
Department of Community Development
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -025
BARTON RESIDENCE
12223 48 AV S TUKW
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 09/16/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
File: Permit File No. D12 -025
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431-3665
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -025
PROJECT NAME: BARTON RESIDENCE
SITE ADDRESS: 12223 48 AV S
X Original Plan Submittal Response to Incomplete Letter #
DATE: 02 -07 -12
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
wildingDivision
A,1S .) / 2- -(,)
Public Works
Aut.\ AYA- ?-6-jtjaP-■
Fire Prevention
Structural ❑
wA- ).
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 02 -09 -12
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03-08-12
Approved Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slipcloc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
S
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.0003
/06/2012
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.0003
/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lniibbip/Print.aspx
03/20/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - 00067701 1 BID PACKAGE M -27
3- 53- 0058 -044
SEPARATE PERMIT
REQUIRED FOR:
Umechanical
pectriCal
WF mbing
Gas Piping
City of Tukwila
BUILDING DIVISION
FILE COPY.
Perr>rittt No.. `)---
P,o frview approval Is sttOct to errors and omt sionsr
of construction documents does not authorize
t , Rio, = of any adopted code or ordinance. Rsclpt
a; ;. tcvea Field Copy and condtions is acknowledged:
By. .-:- '9
Date: 3/40/4.2.,
City Of 1UkwIIa
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
i 77T 77 : -1s uns will require a new plan submittal
c..;,;; may include additional plan review fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 13 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
FEB 0 7 2012
PERMIT CENTER
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Seattle, WA
APPLICABLE CODES:
2009 Seattle Residential Code,
International Fire Code,
International Mechanical Code
0n9001300
I-EGAL DESCRIPTION:
ALLENTOWN ADD
ZONMCs: 5F1200
OCCUPANCY: (No Change)
SNGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V 5 NON SPRINKLERED
DRAWING INDEX
Tom
A1.0
A2.
A2.1
A22
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MI.O LEGENDS, SCI- IEDULES, A513REV, GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
EI. D FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Pox 206. 263. 9233
Fax: 206. 2%. 0190
Contact: Sharyn Parker
E -mail: Sharyn.Parker•1ngcounty.gov
ARCHITECT:
S.M. Stemper Architects P.L.L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph 206. 624. 21-11
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerry'smstemper.com
melodyesmstemper.com
timesmstemper.com
ACOUSTICAL ENGNEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 9ai'
Ph 206. S39.0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119_
Ph: 206. 318. 056S
Fax: 206.318.0641
Contact: Dylan Tumor
E -mail: DylanTegreenbusch,com
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -ma11: bcratreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E, Suite 100
Seattle, WA 98102
pt : 206. 231. S63S
Fax: 206.162.4150
Contact: Tim • -en
E-mail: tim og- enepbsenvcom
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 0200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCortmell•Jonespayne.com
STRUCTURAL ENGINEER
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E -mail: ronmepem- engineers.com
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOiSE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES NO
1 SELECTIVE REPLACEMENT OF EXXISTNG WINDOWS WITH NEW VNYL- FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WNDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING STORM DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
a INSTALLATION OF PET DOORS.
X
9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNr? AND
ASSOCIATED DUCTING.
X
9.13 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
10. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
12. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
13. INSTALLATION OF CHIMNEY CAP.
X
14. INSTALLATION OF SMOKE DETECTORS.
X
15. REGULATED MATERIALS ABATEMENT.
X
ib. ATTIC VENT BAFFLES.
X
11. INSTALLATION OF ATTIC NSULATION.
X
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability- Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
F: (TT 1 ;TE:MPEH
STATE 07 HIiNGT01v
9/20/11
0810.03.1933
H-
O
CL
-J
Z
0
I-
<
z
w
z
0
0
0
Z
AIP NUMBER
MPROVEMENTS
0
Cw
w
w
0)
0
z
U
3 -53- 0058 -044
z
O
1-
Lct
z
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1933
NOTES:
I. ASBESTOS CONTANING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE NDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
NOTE:
INTERIOR TRIM TO BE FNIEHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
b. DOORS OR WNDOW& SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WNDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME PAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERFERE WITH (E) CLOSET SHELVNG, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FNISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POIIER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE NSTALLATION OF TIMERS. PATCH AND FNISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11 CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FNISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTNG WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 16 UNCOVERED.
19. EXISTNG WINDOW COVERINGS MUST BE REINSTALLED 014 THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FNISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
MAIN FLOOR PLAN
1 /4" = 1
A. EAST ELEVATION
12' -5"
/
/
\
A
/I
I I -I - . . . . . _ �-} .
I0 /11
✓ I
I / I!
I L1 r rI
1 24" x 24" EXIST.
. I _ ATTIC ACCESS
1 PANEL �
-
/
-14 71
- .`� ...
= /
/ 1
/ 1
� B
r
B. SOUTH ELEVATION
PLAN KEYNOTES
OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
ODEMOLISH EXISTING DOOR( &), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF.
DOOR 5alEPULE
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH
OMECHANICAL DOCUMENTS.
ONSTALL VENT BAFFLES) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL.
OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A21
ACCESS TO SITE AND PARKING
L THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
LI\ .
li
1I
11
11
/ 11
11
11
11
11
1
/
/
/
ATTIC PLAN
1/4" = 1'
C. WEST ELEVATION
D
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 13 2012
City of Tukwila
BUILDING DIVISION
D. NORTH ELEVATION
RECEIVED
FEB 07 2012
LEGEND
PERMIT CENTE
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
GABLE END VENT BAFFLE
RIDGE VENT BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
- MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT NSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
ATTIC INSULATION
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
11..11
KITCHEN EXHAUST BAFFLE
GAS METER
SOFFIT FOR MECHANICAL DUCTING
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
!.1- I (EC'
T'AT E 0E-
0810.03.1933
9/20/11
O
0-
_J
z
O
aC
z
W
F-
>-
z
F-
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
w
w
w
0
z
H
W
W
5 -53- 0058 -044
z
0
z
1—
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1933
WINDOW TYPES
SINGLE HUNG
2
3
SLIDER CASEMENT
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
BEDROOM 1
1
2' -0" x 4' -5"
PAINT/PAINT
I /A2.0
8
BEDROOM I
3
2' -0" x 4' -5"
PAINT/PAINT
I /42.0
C
BEDROOM 2
I
2' -II" x 4' -5"
PAINT/PAINT
I /42.0
D
BEDROOM 2
1
2' -5" x 4' -5"
PAINT/PAINT
I/42.0
E
BEDROOM 2
3
2' -5" x 4' -5"
PAINT/PAINT
1/42.0
F
KITCHEN
1
2' -8" x 2' -2"
PAINT/PAINT
VA2.0
G
KITCHEN
I
2' -I" x 4' -5"
PAINT/PAINT
1/42.0
H
KITCHEN
I
2' -1" x 4' -5"
PAINT/PAINT
1/42.0
I
LIVING ROOM
2
4' -10" x 4' -3"
PAINT/PAINT
1/42.0
J
LIVING ROOM
2
4' -10" x 4' -3"
PAINT/PAINT
1/42.0
(E) = EXISTING
UNDETERMINED VINYL SIDING SUBSTRATE
(E) BACKER BOARD
(E) VINYL SIDING
(E) EXTERIOR SIE4THNG
CARER,ILLY LIFT (E) WALL I.NDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
FLASHING AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL FROM TOP
OF FLASHNG. LAP (E) WALL UNDERLAYMEN1
OVER TOP OF SELF ADHERING FLASHING.
REMOVE (E) VINYL SIDING AS REQ'D
FOR INSTALLATION OF WNDOW 4
FLASHING. REPLACE/ RE- INSTALL
SIDING 4 ACCESSORIES TO MATCH (E).
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE HELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO SE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
(E) BUILDING PAPER
UNDETERMINED VINYL SIDING SUBSTRATE
(E) GUS
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
WINDOW HEAD
VINYL J CHANNEL TRIM
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PANT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WNDOW ASSEMBLY
SELF - ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY.
SEALANT 4 BACKER ROD
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
VINYL J CHANNEL TRIM
WINDOW JAMB
1
Ie
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL AND BACKER BOARD FOR
NSTALLATION OF WNDOW ASSEMBLY 4
TRIM. REPLACE/ RE- INSTALL SIDING TO
MATCH (E)
(E) BACKER BOARD
(E) VNYL SIDING
r
1
1
1
so-
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. CUT BACK (E) BACKER
BOARD AND (E) VINYL SIDING FOR
INSTALLATION OF SELF ADHERING
Mme. NSTALL SOLID P.T.
BLOCKING TO PROVIDE NAILING
FOR BACKER BOARD. RE- NSTALL
FEPLACEMENT BACKER BOARD 4
(E) VNYL SIDING
(E) EXTERIOR SHEATHING
CONTINUOUS SEALANT, TYP.
(E) GU.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH TO
MATCH (E)
BACKER ROP SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
SOLID WOOD TRIM
SELF- ADI•IERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT 4 ".
CONTINUOUS SEALANT, TYP.
LAP SELF ADHERING
MEMBRANE AT JAMBS
OVER TOP OF SILL
MEMBRANE EXTENSIONS
(E) GWB
WINDOW SILL
VINYL SIDING - WINDOW DETAIL SET
3 " =1' -0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08600 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 13 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
FEB 07 2012
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
COTT T EMPE
TrTE 0='° HIICTON
9/20/11
0810.03.1933
O
0
J
z
0
I-
Q
z
w
z
1-
Z
0
U
0
z
AIP NUMBER
MPROVEMENTS
0
cw
w
w
0
z
LL
U
0
U.1
5-53- 0058 -044
0
F—
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1933
DOOR TYPES
L: D
A
FLUSH SCW
3 LITES, 3 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
5
FLUSH SCW
I LITE W/
2 PANELS
W/SAFETY GLAZING
G
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR I ROOM
NO I LOCATION
DOOR SIZE FINISH I HARDWARE
TYPE W x H INT./ EXT. SET / FINISH
1
2
3
ENTRY
KITCHEN
ENTRY
A
3' -0" x 6' -8"
PANT/PAINT
C
3' -0" x 6' -8"
PAINT/PANT
14W-1/616
KNOB / LEVER
SET
LOCK DETAIL
SET SET
HW -1 / bib
DK -3 (NEPTUNE)
DK -3 (NEPTUNE)
3' -0" x 6' -8"
I
LOCK -1 /A2.1
LOCK -1 I 2 /A2.I
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH TIE OPERATION OF TI-4E
EXISTING SLIDNG GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E) VINYL SIDING
BACKER HOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDNG AS REQ'D FOR
INSTALLATION OF DOOR ASSEMBLY 4
TRIM. REPLACE W/ NEW SIDING,
ACCESSORIES, 4 BLOCKING TO MATCH (E)
SHIM BACKER BOARD AS
REQUIRED
(E) WALL UNDERLAYMENT
PRE- PRIMED, GALV SWEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
N THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MM.
(E) EXTERIOR SHEATHING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTNUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
CAREFULLY LIFT (E) WALL INDERLAYMENT AND
INSTALL. TOP EDGE OF SELF ADHERNG
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF ADHERING
MEMBRANE 4" UP WALL FROM TOP OF
FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL AS REQ'D FOR
INSTALLATION OF POOR ASSEMBLY 4 TRIM.
REPLACE W/ NEW SIDING, ACCESSORIES, 4
BLOCKING TO MATCH (E)
CONTNUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR HEAD
SHIM BACKER BOARD
AS REQUIRED
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
5141M AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATI#R STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR 5140E
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
DOOR JAMB
DOOR SILL
VINYL SIDING - DOOR DETAIL SET
3 " =1' -0"
SHIM AS NECESSARY
FILL GAP UU BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTNUOUS WEATHER
STRIPPNG
KERF IN CONTINUOUS
WEATHER STRIPPING
(E) »" GWB
514IM AS NECESSARY
FILL GAP W/ BATT
INSULATION
HACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KERF IN CONTINUOUS
WEATHER STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR SHOE
DOOR HEAD
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
INTERIOR DOOR PER
SCHEDULE
DOOR JAMB
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
EXISTING FLOOR STRUCTURE
DOOR SILL
EXISTING FRAMING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
DOOR PER SCI- IEDULE
VINYL SIDING - DOOR DETAIL SET
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 13 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
FEB 0'7 2012
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
_err TEMPS
STATE 0= SHINGTO
9/20111
0810.03.1933
O
0
-J Z
Q O
Z F--
Q w c�
Z
w
w 0
Z J
I
Z U F-
U <
Vr J
Z
w
w
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1933
(E) BACKER BOARD
(E) VNYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDING AS REQ'D FOR
INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING,
ACCESSORIES, 4 BLOCKING TO MATCH (E).
PRE - PRIMED, GALV SWEET METAL
FLASHING LW FF. END GAPS UNDER
SURFACE MOUNTED REGLET AND CAP
FLASHING. PAINT COLOR TO BE
SELECTED IN THE HELD
PANT VENTILATION FIXTURE,
COLOR TO BE SELECTED IN
NE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PANT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
SWIM BACKER BOARD AS
REQUIRED
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
REPLACEMENT SIDING AS REQUIRED
2X BLOCKING
2X2 BLOCKING, 4 SIDES
(P.T.)
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
INSULATION DAM DETAIL
3" = 1' -0"
INSULATION
INSULATION DAM
(E) WALL FRAMING
SELF- ADHERING
MEMBRANE TO
WRAP ENTIRE
CORNER POST
CONT. SEALANT
ACOUSTICAL
WINDOW ASSEMBLY
VINYL COVER TRIM
TO MATCH WINDOW
ASSEMBLY UNIT
CONTINUOUS SEALANT AT
PERIMETER OF WINDOW FRAME
CORNER POST DETAIL
3 " =1' -0"
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
NEW SOLID P.T. BLOCKING (2)
SIDES AROUND PIPE COLUMN.
ATTACH W/ 1/4 -20 COUNTER-
SUNK SCREWS W/ WASHERS
IN DRILLED AND TAPPED
HOLES • 24" O.C„ TYP.
INSULATION
(E) PIPE COLUMN
WD. TRIM. FINISH
TO MATCH EXIST.
SEALANT AND
BACKER ROD, TYP.
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
It CLEAR AIR SPACE
NEW 2 "X SPACER
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW 1" NSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
ROOF VENT BAFFLE DETAIL
3" = 1' - 0"
REVIEWED FOR
CODE COMPLIANCE
k, APPROVED
FEB 13 2012
City of Tukwila/
BUILDING DIVISION
RECEIVED
FEB 0 7 2012
PERMIT CENTER
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
coCTT
51ATi_ 0-
9/20/11
0810.03.1933
0
0
ce
Q �
-� 0
W -
I— Z
Q W CO
Cn Q
w
Z J_
LL
Z U I-
D
O
0 �t
0 --
Z <
w
0
U)
ww
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
MISC.
DETAILS
A2.2
0810.03.1933
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 1 -IR" OVER
(E) BLDG. PAPER AT
SILL. EXTEND 1 1"
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROO��U�GH RO. AS
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
" MN
MEMBRANE FLASHING AT SILL
Jf9 5
zo
5MEEELY COLS NER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JABS AND HEAD. '\
(E) SIDING NOT
SHOWN N FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE N SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HDLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
i
'
O
o
e
\
0
e
0 O "
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4 i WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDNG, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOIIN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHNG AT
JAMBS
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
j>.BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRM
(FOLLOWINCs STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDNG NOT SHOU N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
'\\
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
(/\\ MEMBRANE FLASHING AT SILL
5 SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
SHOUJN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW 1/6" CLEARANCE
BETWEEN FLASHING AND
DOT. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO. AT l-IEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHNG TO
OUTSIDE FACE OF
WALL 51- IATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
(6) MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADI4EARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 14A5 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "s AND 5" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHNG
1-1A5 BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDNG. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDNG.
LEAVE V4" -3/8" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
WINDOW FLASHING INSTALLATION
SCALE: NTS
(40.1-o-zs
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 13 2012
•
' City ofTukwila
BUILDING DIVISION
RECEIVED
FEB 07 2012
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
C•ou
S1 "ATE 0
0810.03.1933
REGISTERED
9/20/11
O
CL
Ce
—J
z
O
z
w
z
z
0
0
0
AIP NUMBER
MPROVEMENTS
5-53- 0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
L B &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1933
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
we
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
OR XX.
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT UNE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
SXX
ABBR
-el- el-
EQUIP ID�R �.
NG
•
0
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
337
<.08 "WG
7 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
90
337
<.08 "WG
7 "0
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1933
807
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC. GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDI110NED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DITIONAL STEEL. SUPPORT BRACKETS, HANGERS,
D
N ,.
•
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
o,_
MECHANICAL VENTILATION CALCULATION
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 1,5_
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
RECEIVED
FEB 07 2012
PERMIT CENTER
SEPARATE
PERMIT
1 EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited t1.Liub Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 0024 -1870
THE GREENBUSCH GROUP, INC
••••••••• )
AOOUSIIGI., M ! vom NFX*WII�1. ol0pililNS
1000 our stIIi>7 SUIE 201 SE= 10106114
(206) 376-0569 (206) 376 -0641 FAX
0810.03.1933
H
Et
0
a
J
Z
0
ct
w
z
z
0
U
0
z
AIP NUMBER
3- 53- 0058-044
z
0
F--
0
z
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1933
EXPIRES: 9/08/2012 I
TYP
SEE
(E)SG
BEDROOM
2
N (E)SG
(E)EG
SATN
24' x 24'
ATTIC
PANEL
SOFFIT, REFER TO
ARCHITECTURAL
(E)SG
EYKI
CLOSET
BEDROOM
KITC4.4EN
CEILING
(I)<
LIVING
ROOM
LAUNDRY
ROOM
(E)SG
(E)sG
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
z
w
w
FURNACE
(E)SUPPLY
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
GAS
METER
NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER WAC 51 -52- 0403.8.3.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL
CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH
ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8.
CONTRACTOR TO FIELD VERIFY ACTUAL THERMOSTAT LOCATION.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME, OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
SCALE: NONE
hios
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
FEB 07 2012
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A Professional Limited Liabilloq Conr.w
4000 DELRIDGE WAY SW
SUITE 200 • SEATI'LE, WA 96108
(206) 024 -8777 • FAX (200) 624 -8970
THE GREENBUSCH GROUP, INC
AODUSIIGL swig lclw�rr . P191 19
190o wear SIFT lUIE 901 S TL(. A191111
(20e) 376 -O66Y (209) 376 -0141 FAX
0810.03.1933
NTERNATIONAL AIRPORT
0
U
MPROVEMENTS
AIP NUMBER
3-53- 0058 -044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED
BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL.
PLAN AND
DETAILS
M2.0
0810.03.1933
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACIUTATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
SEDIRCOM
2
24" x 24" E
ATTIC ,CC SS
PANEL L
ELECTRICAL. LEG E1•11)
SYhIBOL
DESCRIPTION
SYMBOL
DESCRIPTION
UGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
111
ii
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2'C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
} INDICATES ISOLATED GROUND.
I,
4
DAMPER CONNECTION
D
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
EP
TOGGLE TYPE MOTOR DISCONNECT SWATCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
®
SMOKE DETECTOR
-- ----,--
cJ
ELECTRICAL METER
i
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
OT
THERMOSTAT
- --
E
CLING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT
O
UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
1UNDRY
\ RCCM
KITCI -EN
CL_OeET LJ
MAIN FLOOR PLAN
TO RistiacE
DAMPER
LI' ✓INix
iROOM
1/4" = 1'
NORTH
ors
RECEIVED
FEB 07 2012
PERMIT CENTER
SEPARATE 4
PERMIT �
REQUIRED
111
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624 -2777 • FAX (206) 024 -2973
•
■N�INIIRa. INC
.. SEM ONW1 OM WI
UMW ONWPWW
ILIWOON 41WW WA WNW
PAN INOW AIR OWN
0810.03.1933
0
0
cc
—J
0
z
0C
z
z
0
0
z
AIP NUMBER
MPROVEMENTS
a
W
2
W
CIL
W
U)
0
z
LL
U
J
W
CI
w
5- 53-0058 -043
SEATTLE WASHINGTON
DATE
9/8/11
ISSUED M -27
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1933