Loading...
HomeMy WebLinkAboutPermit D12-025 - BARTON RESIDENCE - UGPRADESBARYON RESIDENCE 12223 48 AV S D12 -025 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179001300 Address: 12223 48 AV S TUKW Suite No: Project Name: BARTON RESIDENCE DEVELOPMENT PERMIT Permit Number: D12-025 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: BARTON SANDRA S Address: 12223 48TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $25,087.00 Fees Collected: $993.76 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -025 Printed: 03 -20 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N s • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: r)-Cl t I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 4,77 Zee Goer r y This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 012 -025 Printed: 03 -20 -2012 this requirement. 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall m the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -025 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http../Iwww.ci.tukwila.iva.us Building Permi £ No. b U-r- O Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12223 48th Avenue S. Tenant Name: Sandra S. Barton Property Owners Name: Sandra S. Barton Mailing Address: 12223 48th Avenue S. King Co Assessor's Tax No.: 0179001300 Suite Number: Floor: New Tenant: ❑ Yes ® ..No Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: city Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: H:Wpphcations\Porms- Apphcattons On Line\2009 Apphcattons\l -2009 - Permit Applicanon.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 25,087 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications,Forms- Applications On Line,2009 Applications`.I -2009 - Permit Application.doc Revised: 1.2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 750 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications,Forms- Applications On Line,2009 Applications`.I -2009 - Permit Application.doc Revised: 1.2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: (r- F-e.(9 Zo tZ Day Telephone: !— P (0 24 - �► Mailing Address: City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:'Applicat ions \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPINOERMIT INFORMATION - 206 -431 7 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:'Applications'• Forms - Applications On- tinc•2009 Applicatiotu'.1 -2009 Permit Application.doc Revucd, 1 -2009 bh Page 5 of 6 CA, of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION RECORD Retain a copy with permit ..7/ INSPECTION NO. PERMIT NO._ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vz, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 6 A 71_-'-00 `- y,y' -, Type of Inspection: q 1 ,'-1.\ L. _- C.:7('CL%.,' • .•; Address: ' ' •..::) E AU r; Date Called: . 'Li-) cFE' '• , Special Instructions: / / / Date Wanted:. 1 i iri 1; 2 ,a.m. p.m. Requestdr: Phone No: '_-`5 ` 1 -. . • 7 `i `' ?. f Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspectdr: !I F-7 REINSPECTION FEE EQUIRED. prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r i Date: / t �' 1, II [ ssu?atioio Certificate / Blower Door Test Form III 11a (�1 Batts and Blankets When Installed in accordance with the manufacturer's recommendations. Knauf batts and blankets will provide the full R- value. insular,or. Northwest LLC ktikatetu CITY OFTtH<II of n NOV 1 4 2012 PERMIT CENTER Thermal Performance (Attic Application) ne required number o; The stated dnermal resistance (R- value) is provioed by installing in accordance with the manufactuers instructions, bags per 1,000 sq.R of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness wall result in lower insulation R- value. R- Value` Minimum Thickness R- Value' 1Ba s /1,000 sy. ft I Maximum Covera a Minimum Wei•fit Minimum Thickness y cover more roan: insulation should not be not be less than.: 75 Obtain An insulation Installed insulation should I o Obtain an insulation The number of ontents of this Sag should not The weight/SF of installed Installed insulation should resistance (R- Value) of: not be less than,: resistance (R- Vaiue) or: bags /1 000 :;F of net I less than. area should not be 19.75" R -60 I 31.7 31.5 SF 1 .952 LOS I 16.75" R-38HD I 10.25" I 38.7 SF I .774 LBS 12.00" I R-49 I 25.8 .663 LBS II 14 -75" R-38 45.3 SF R-30HD I 8.25" R-44 I 22.1 52.7 SF I .569 LBS I 13.00" 10.00" R -38 I 19.0 .431 LBS I 10 -25" R -2 I 14.4 I 697 SF 9.00" R -26 I 9.00" R -30 I 12 4 I 80.9 SF .371 LBS R -22 I 6.50" R -26 I 95.8 SF .313 LBS 7.75" 5.50" R -22 I 10.4 .268 LBS I 6.75" R-21HD I 8.9 1 111.8 SF R -19 I 6.25 "" R-19 I 4.75" i 164.3 SF .183 LBS 3.50" R-13 I 6 -1 I .152 LBS I 4.00 R-15HD 1 5.1 I 197.6 SF requirements R -13 I 3.50" R -11 I 3.50" Bag Weight Federal -Nominal 30 ibs., Minimum 29 : T Type sirs B. R -Values ues are de ern' ed performance n accordance withf C 687 and C 51 . " "R" means Type I, and R -11 cancelled Federal Saecifica5on Fitt -I- :0308, Y^ R -8 2.50 resistance tc heat flow. The higher the P.-value. the greater the insulation power. To get the marked R- value, it is eseential `,'nat the R -er in a 55" cavity. Co -521F to ASTM C665 and insulation be installed properly If you do it yourself, get instructions and follow them carefully. Federal Specification HI- I -521F. To achieve labeled R- value, this product must be applied with a pneumatic blowing machne and a corrugated hose with a minimum 25" interval corrugation, a minimum length cf 150 ft. and a a,arreter of at least 3 ". Coils In the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 lbs. /minute. Recommended feed rate is 15- 25Ibs. /mmu52 Builders Insulation Statement Batts and/or blankets have been installed in conformance with the above recommenda30! 5 to provide a thermal resistance of... •Attic Area 1'R. (Sloped Ceilings IR- Walls I R- Floors (over an unheated crawl space) 1R- Completed as of: Site Address: Home Builder Signature: Home Builder Address: R -Value 2009 W./i1SEC Residential Energy Compliance Certificate - Building Air Leakage Buildino & Test Condition Comments Date: Time: Indoor Temperature: Outdoc" Termperature: Floor Area (fb) I Standard R-49 R -38 1 R -21 R -30 '% 5 %2 /4Z223-4'.0exMe 5o• rel&zi% 14 o, l N (Insulation 'Contractor: Insulation Northwest LLC P.O. Box 732069 Puyallup, WA 98373 Phone: (253) 846 -0121 Fax: (253) 846-8096 Buildin3 Air Leaka,e Target: SLA Less than 0.00030 Test #1 Depress ._ Press ._ Pretest Baseline Pressure: (Pe) Bldg Press. (Pa) Flow Ring Fan Press. I Flow (cfm) (Pa) Post -Test Pressure: - (Pa) Fan Model /SN: Results: SLA (Specific Leakage Area): Test #2 Depress . . Press .� Pretest Baseline Pressure: (Pa) Sidg Press. (Pa(\ Flow Ring Fan Press. (Pa) . 1 Post -Test Pressure: . (Pa) Fan Model /SN: Results: SLA (Specific Leakage Area): Flow (cfm) Affidavit: certify that this Specific Leakage Area is accurate 2no ceter nineo us:rg B',cwer Door Test Standard 502.4.5 Building Al Leakage Testing. harne Technician Signature 1 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANRIP Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers DI2 -025 through DI2 -039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Jen 'fer Mar• e it echn File: Permit No. DI2 -025 through D12 -039 W:\Permit Center \Extension Letters \Pennits\2012 \D12 -025 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 • S.M. STEMPER ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y 13 September 2012 Bill Rambo, Permit Technician City ofTukwila, Department of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Rambo, This letter serves as written request to extend the perm its listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RAN RIP). Permit Address Permit Number Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034 5003 S. 1 13th St. D12 — 027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036 5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12 — 037 11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039 12203 47th Ave S. D12 — 032 Permits for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original permits. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 -721 -0061 or tfenlason@onespayne.com. a , Aei llai die ci/7400/Z Timothy J. Fenlason Project Manager The Jones Payne Group, Inc. CITY OF TUKWILA SP 13 20121 PERMIT CENTER euP oi Iiull2 4000 DELRIDGE WAY SW . SUITE 200 . SEATTLE, WA 98106 • 206/ 624 -2777 . FAX 206/ 624-2973 k- 14\ 'lc 11, 10 -01 -2012 City of f 'Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -025 BARTON RESIDENCE 12223 48 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15 /2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Marshall Technician File: Permit File No. D12 -025 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 08 -01 -2012 City of Tukwila Department of Community Development SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -025 BARTON RESIDENCE 12223 48 AV S TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. File: Permit File No. D12 -025 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431-3665 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -025 PROJECT NAME: BARTON RESIDENCE SITE ADDRESS: 12223 48 AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 02 -07 -12 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: wildingDivision A,1S .) / 2- -(,) Public Works Aut.\ AYA- ?-6-jtjaP-■ Fire Prevention Structural ❑ wA- ). Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -09 -12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-08-12 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slipcloc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 S • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.0003 /06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lniibbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - 00067701 1 BID PACKAGE M -27 3- 53- 0058 -044 SEPARATE PERMIT REQUIRED FOR: Umechanical pectriCal WF mbing Gas Piping City of Tukwila BUILDING DIVISION FILE COPY. Perr>rittt No.. `)--- P,o frview approval Is sttOct to errors and omt sionsr of construction documents does not authorize t , Rio, = of any adopted code or ordinance. Rsclpt a; ;. tcvea Field Copy and condtions is acknowledged: By. .-:- '9 Date: 3/40/4.2., City Of 1UkwIIa BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. i 77T 77 : -1s uns will require a new plan submittal c..;,;; may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 7 2012 PERMIT CENTER SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CODES: 2009 Seattle Residential Code, International Fire Code, International Mechanical Code 0n9001300 I-EGAL DESCRIPTION: ALLENTOWN ADD ZONMCs: 5F1200 OCCUPANCY: (No Change) SNGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V 5 NON SPRINKLERED DRAWING INDEX Tom A1.0 A2. A2.1 A22 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MI.O LEGENDS, SCI- IEDULES, A513REV, GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS EI. D FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Pox 206. 263. 9233 Fax: 206. 2%. 0190 Contact: Sharyn Parker E -mail: Sharyn.Parker•1ngcounty.gov ARCHITECT: S.M. Stemper Architects P.L.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph 206. 624. 21-11 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerry'smstemper.com melodyesmstemper.com timesmstemper.com ACOUSTICAL ENGNEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 9ai' Ph 206. S39.0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119_ Ph: 206. 318. 056S Fax: 206.318.0641 Contact: Dylan Tumor E -mail: DylanTegreenbusch,com ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -ma11: bcratreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 98102 pt : 206. 231. S63S Fax: 206.162.4150 Contact: Tim • -en E-mail: tim og- enepbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCortmell•Jonespayne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepem- engineers.com SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOiSE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES NO 1 SELECTIVE REPLACEMENT OF EXXISTNG WINDOWS WITH NEW VNYL- FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WNDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X a INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNr? AND ASSOCIATED DUCTING. X 9.13 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. X 14. INSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X ib. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC NSULATION. X ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability- Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 F: (TT 1 ;TE:MPEH STATE 07 HIiNGT01v 9/20/11 0810.03.1933 H- O CL -J Z 0 I- < z w z 0 0 0 Z AIP NUMBER MPROVEMENTS 0 Cw w w 0) 0 z U 3 -53- 0058 -044 z O 1- Lct z DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1933 NOTES: I. ASBESTOS CONTANING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE NDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. NOTE: INTERIOR TRIM TO BE FNIEHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. b. DOORS OR WNDOW& SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WNDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME PAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERFERE WITH (E) CLOSET SHELVNG, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FNISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POIIER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE NSTALLATION OF TIMERS. PATCH AND FNISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11 CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FNISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTNG WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 16 UNCOVERED. 19. EXISTNG WINDOW COVERINGS MUST BE REINSTALLED 014 THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FNISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. MAIN FLOOR PLAN 1 /4" = 1 A. EAST ELEVATION 12' -5" / / \ A /I I I -I - . . . . . _ �-} . I0 /11 ✓ I I / I! I L1 r rI 1 24" x 24" EXIST. . I _ ATTIC ACCESS 1 PANEL � - / -14 71 - .`� ... = / / 1 / 1 � B r B. SOUTH ELEVATION PLAN KEYNOTES OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. ODEMOLISH EXISTING DOOR( &), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF. DOOR 5alEPULE DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH OMECHANICAL DOCUMENTS. ONSTALL VENT BAFFLES) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL. OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A21 ACCESS TO SITE AND PARKING L THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. LI\ . li 1I 11 11 / 11 11 11 11 11 1 / / / ATTIC PLAN 1/4" = 1' C. WEST ELEVATION D REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION D. NORTH ELEVATION RECEIVED FEB 07 2012 LEGEND PERMIT CENTE ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW GABLE END VENT BAFFLE RIDGE VENT BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. - MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT NSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION SD INSTALL BATTERY OPERATED SMOKE DETECTORS 11..11 KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTING • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 !.1- I (EC' T'AT E 0E- 0810.03.1933 9/20/11 O 0- _J z O aC z W F- >- z F- z 0 U z AIP NUMBER MPROVEMENTS 0 w w w 0 z H W W 5 -53- 0058 -044 z 0 z 1— DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH FLOOR PLANS NOTES A1.0 0810.03.1933 WINDOW TYPES SINGLE HUNG 2 3 SLIDER CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A BEDROOM 1 1 2' -0" x 4' -5" PAINT/PAINT I /A2.0 8 BEDROOM I 3 2' -0" x 4' -5" PAINT/PAINT I /42.0 C BEDROOM 2 I 2' -II" x 4' -5" PAINT/PAINT I /42.0 D BEDROOM 2 1 2' -5" x 4' -5" PAINT/PAINT I/42.0 E BEDROOM 2 3 2' -5" x 4' -5" PAINT/PAINT 1/42.0 F KITCHEN 1 2' -8" x 2' -2" PAINT/PAINT VA2.0 G KITCHEN I 2' -I" x 4' -5" PAINT/PAINT 1/42.0 H KITCHEN I 2' -1" x 4' -5" PAINT/PAINT 1/42.0 I LIVING ROOM 2 4' -10" x 4' -3" PAINT/PAINT 1/42.0 J LIVING ROOM 2 4' -10" x 4' -3" PAINT/PAINT 1/42.0 (E) = EXISTING UNDETERMINED VINYL SIDING SUBSTRATE (E) BACKER BOARD (E) VINYL SIDING (E) EXTERIOR SIE4THNG CARER,ILLY LIFT (E) WALL I.NDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHNG. LAP (E) WALL UNDERLAYMEN1 OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WNDOW 4 FLASHING. REPLACE/ RE- INSTALL SIDING 4 ACCESSORIES TO MATCH (E). PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE HELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO SE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD (E) BUILDING PAPER UNDETERMINED VINYL SIDING SUBSTRATE (E) GUS (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WINDOW HEAD VINYL J CHANNEL TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT 4 BACKER ROD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM WINDOW JAMB 1 Ie UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR NSTALLATION OF WNDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) (E) BACKER BOARD (E) VNYL SIDING r 1 1 1 so- SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING Mme. NSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER BOARD. RE- NSTALL FEPLACEMENT BACKER BOARD 4 (E) VNYL SIDING (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. (E) GU. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCH (E) BACKER ROP SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD SOLID WOOD TRIM SELF- ADI•IERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". CONTINUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08600 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION RECEIVED FEB 07 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT T EMPE TrTE 0='° HIICTON 9/20/11 0810.03.1933 O 0 J z 0 I- Q z w z 1- Z 0 U 0 z AIP NUMBER MPROVEMENTS 0 cw w w 0 z LL U 0 U.1 5-53- 0058 -044 0 F— z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1933 DOOR TYPES L: D A FLUSH SCW 3 LITES, 3 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT 5 FLUSH SCW I LITE W/ 2 PANELS W/SAFETY GLAZING G EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR I ROOM NO I LOCATION DOOR SIZE FINISH I HARDWARE TYPE W x H INT./ EXT. SET / FINISH 1 2 3 ENTRY KITCHEN ENTRY A 3' -0" x 6' -8" PANT/PAINT C 3' -0" x 6' -8" PAINT/PANT 14W-1/616 KNOB / LEVER SET LOCK DETAIL SET SET HW -1 / bib DK -3 (NEPTUNE) DK -3 (NEPTUNE) 3' -0" x 6' -8" I LOCK -1 /A2.1 LOCK -1 I 2 /A2.I 1/A2.1 TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH TIE OPERATION OF TI-4E EXISTING SLIDNG GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) VINYL SIDING BACKER HOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDNG AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT PRE- PRIMED, GALV SWEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MM. (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTNUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY LIFT (E) WALL INDERLAYMENT AND INSTALL. TOP EDGE OF SELF ADHERNG MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL AS REQ'D FOR INSTALLATION OF POOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) CONTNUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR HEAD SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 5141M AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATI#R STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR 5140E 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL VINYL SIDING - DOOR DETAIL SET 3 " =1' -0" SHIM AS NECESSARY FILL GAP UU BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTNUOUS WEATHER STRIPPNG KERF IN CONTINUOUS WEATHER STRIPPING (E) »" GWB 514IM AS NECESSARY FILL GAP W/ BATT INSULATION HACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KERF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE DOOR HEAD CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM INTERIOR DOOR PER SCHEDULE DOOR JAMB AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM DOOR PER SCI- IEDULE VINYL SIDING - DOOR DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION RECEIVED FEB 0'7 2012 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 _err TEMPS STATE 0= SHINGTO 9/20111 0810.03.1933 O 0 -J Z Q O Z F-- Q w c� Z w w 0 Z J I Z U F- U < Vr J Z w w MPROVEMENTS AIP NUMBER 5 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1933 (E) BACKER BOARD (E) VNYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PRE - PRIMED, GALV SWEET METAL FLASHING LW FF. END GAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN THE HELD PANT VENTILATION FIXTURE, COLOR TO BE SELECTED IN NE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PANT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. SWIM BACKER BOARD AS REQUIRED SELF ADHERING BITUMINOUS MEMBRANE FLASHING REPLACEMENT SIDING AS REQUIRED 2X BLOCKING 2X2 BLOCKING, 4 SIDES (P.T.) 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3" = 1' -0" INSULATION INSULATION DAM (E) WALL FRAMING SELF- ADHERING MEMBRANE TO WRAP ENTIRE CORNER POST CONT. SEALANT ACOUSTICAL WINDOW ASSEMBLY VINYL COVER TRIM TO MATCH WINDOW ASSEMBLY UNIT CONTINUOUS SEALANT AT PERIMETER OF WINDOW FRAME CORNER POST DETAIL 3 " =1' -0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW SOLID P.T. BLOCKING (2) SIDES AROUND PIPE COLUMN. ATTACH W/ 1/4 -20 COUNTER- SUNK SCREWS W/ WASHERS IN DRILLED AND TAPPED HOLES • 24" O.C„ TYP. INSULATION (E) PIPE COLUMN WD. TRIM. FINISH TO MATCH EXIST. SEALANT AND BACKER ROD, TYP. EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2 "X SPACER AS REQUIRED TO PROVIDE It CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" NSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 3" = 1' - 0" REVIEWED FOR CODE COMPLIANCE k, APPROVED FEB 13 2012 City of Tukwila/ BUILDING DIVISION RECEIVED FEB 0 7 2012 PERMIT CENTER ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED coCTT 51ATi_ 0- 9/20/11 0810.03.1933 0 0 ce Q � -� 0 W - I— Z Q W CO Cn Q w Z J_ LL Z U I- D O 0 �t 0 -- Z < w 0 U) ww MPROVEMENTS AIP NUMBER 5 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH MISC. DETAILS A2.2 0810.03.1933 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -IR" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 1" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROO��U�GH RO. AS ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING " MN MEMBRANE FLASHING AT SILL Jf9 5 zo 5MEEELY COLS NER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JABS AND HEAD. '\ (E) SIDING NOT SHOWN N FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE N SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HDLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. i ' O o e \ 0 e 0 O " ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4 i WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDNG, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOIIN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHNG AT JAMBS MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. j>.BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRM (FOLLOWINCs STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOU N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. '\\ INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. (/\\ MEMBRANE FLASHING AT SILL 5 SCALE: NTS INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHOUJN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1/6" CLEARANCE BETWEEN FLASHING AND DOT. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. AT l-IEAD AND JAMBS. ADHERE PENETRATION FLASHNG TO OUTSIDE FACE OF WALL 51- IATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (6) MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADI4EARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 14A5 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "s AND 5" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHNG 1-1A5 BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDNG. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDNG. LEAVE V4" -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. WINDOW FLASHING INSTALLATION SCALE: NTS (40.1-o-zs REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 • ' City ofTukwila BUILDING DIVISION RECEIVED FEB 07 2012 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 C•ou S1 "ATE 0 0810.03.1933 REGISTERED 9/20/11 O CL Ce —J z O z w z z 0 0 0 AIP NUMBER MPROVEMENTS 5-53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B &JH WINDOW FLASHING DETAILS A2.3 0810.03.1933 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB we WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL OR XX. 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT UNE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SXX ABBR -el- el- EQUIP ID�R �. NG • 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 <.08 "WG 7 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 90 337 <.08 "WG 7 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1933 807 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC. GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDI110NED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DITIONAL STEEL. SUPPORT BRACKETS, HANGERS, D N ,. • 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. o,_ MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) 1,5_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM RECEIVED FEB 07 2012 PERMIT CENTER SEPARATE PERMIT 1 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited t1.Liub Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 0024 -1870 THE GREENBUSCH GROUP, INC ••••••••• ) AOOUSIIGI., M ! vom NFX*WII�1. ol0pililNS 1000 our stIIi>7 SUIE 201 SE= 10106114 (206) 376-0569 (206) 376 -0641 FAX 0810.03.1933 H Et 0 a J Z 0 ct w z z 0 U 0 z AIP NUMBER 3- 53- 0058-044 z 0 F-- 0 z DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1933 EXPIRES: 9/08/2012 I TYP SEE (E)SG BEDROOM 2 N (E)SG (E)EG SATN 24' x 24' ATTIC PANEL SOFFIT, REFER TO ARCHITECTURAL (E)SG EYKI CLOSET BEDROOM KITC4.4EN CEILING (I)< LIVING ROOM LAUNDRY ROOM (E)SG (E)sG MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC FLOOR z w w FURNACE (E)SUPPLY OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE GAS METER NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. CONTRACTOR TO FIELD VERIFY ACTUAL THERMOSTAT LOCATION. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME, OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE hios SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED FEB 07 2012 PERMIT CENTER S.M. STEMPER ARCHITECTS A Professional Limited Liabilloq Conr.w 4000 DELRIDGE WAY SW SUITE 200 • SEATI'LE, WA 96108 (206) 024 -8777 • FAX (200) 624 -8970 THE GREENBUSCH GROUP, INC AODUSIIGL swig lclw�rr . P191 19 190o wear SIFT lUIE 901 S TL(. A191111 (20e) 376 -O66Y (209) 376 -0141 FAX 0810.03.1933 NTERNATIONAL AIRPORT 0 U MPROVEMENTS AIP NUMBER 3-53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL. PLAN AND DETAILS M2.0 0810.03.1933 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACIUTATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. SEDIRCOM 2 24" x 24" E ATTIC ,CC SS PANEL L ELECTRICAL. LEG E1•11) SYhIBOL DESCRIPTION SYMBOL DESCRIPTION UGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. 111 ii BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2'C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. } INDICATES ISOLATED GROUND. I, 4 DAMPER CONNECTION D NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD EP TOGGLE TYPE MOTOR DISCONNECT SWATCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ® SMOKE DETECTOR -- ----,-- cJ ELECTRICAL METER i TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. OT THERMOSTAT - -- E CLING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT O UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR 1UNDRY \ RCCM KITCI -EN CL_OeET LJ MAIN FLOOR PLAN TO RistiacE DAMPER LI' ✓INix iROOM 1/4" = 1' NORTH ors RECEIVED FEB 07 2012 PERMIT CENTER SEPARATE 4 PERMIT � REQUIRED 111 S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (206) 024 -2973 • ■N�INIIRa. INC .. SEM ONW1 OM WI UMW ONWPWW ILIWOON 41WW WA WNW PAN INOW AIR OWN 0810.03.1933 0 0 cc —J 0 z 0C z z 0 0 z AIP NUMBER MPROVEMENTS a W 2 W CIL W U) 0 z LL U J W CI w 5- 53-0058 -043 SEATTLE WASHINGTON DATE 9/8/11 ISSUED M -27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1933