Loading...
HomeMy WebLinkAboutPermit D12-029 - JACKSON RESIDENCE - UPGRADESJACKSON RESIDENCE 5023 S 124 ST D12 -029 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http://www.TukwilaWA.gov Parcel No.: 0179002285 Address: 5023 S 124 ST TUKW Suite No: Project Name: JACKSON RESIDENCE DEVELOPMENT PERMIT Permit Number: D12-029 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: JACKSON EMMETT L Address: 5023 S 124TH ST , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01 /2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $25,113.00 Fees Collected: $993.76 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -029 Printed: 03 -20 -2012 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: ✓L/ Date: �-4)-Ck(o'L I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Le (jry o 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12 -029 Printed: 03 -20 -2012 this requirement. • 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -029 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.iva.us Building Perim No. 1)- - op� Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 5023 S. 124th St. Tenant Name: Emmett L. Jackson Property Owners Name: Emmett L. Jackson Mailing Address: 5023 S. 124th St. King Co Assessor's Tax No.: 0179002285 Suite Number: Floor: New Tenant: ❑ Yes ..No Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: H:Wpplications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: I -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ -23,1 /3 451 1 7 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes pi No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. .H:1Applications,Fonns- Applications On Line 2009 Applications\ 1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 1,220 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes pi No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. .H:1Applications,Fonns- Applications On Line 2009 Applications\ 1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: 4 v, ■ 2 Day Telephone: ".4 —Z T Mailing Address: City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Apphcatuons\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN RMIT INFORMATION — 206 -4370 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medial gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:1Applications'Forms- Applications On- Line'2009 Applications•1.2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cif of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: hig)://www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION NO. INSPECTION RECORD Retain a copy with permit:Da-0 2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Tr— ProjtL:. `! fo:i iQ s . Typ af%Inspect n: t -, 4'J A N ,, .1.. 6 Address;, 23 ZL'� 11 ST- Date Called: Special Instructions: 1 Date Wanted:. 1 (- f - 1 Z,,,.__ p.m. Requester: Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6ii--z:-Ao, 4 Thoof Inspect C Date: C REINSPECTION FEE REQUIRED. Prior to next inspection, fee,must be paid at 6300 Southcenter Btvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit, INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING.DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v_ (206) 431 -36701 Permit Inspection Request Line (206) 431 -2451 Project: ,:c' S'c&, ,!'5 Type of Inspection: /Air-7 L. - Address: _ 5 D.2 7 S 42 `/ S Date Called: Special Instructions: Date Wantegl:. // // ,t /'? a.m an, Requester: Ph ' 7- 2 Approved per applicable codes. orrections required prior to approval. COMMENTS: Inspec(or: (Date: ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 11/15/2012 16:18 4252282428 N TRON CONSTRUCTION PAGE 02/02 IntulSUCI North• ekt LLC fAciLsis H �f E S 11 �C�° 1 0TH ��2 bsuIatioB CeirA icate / Blower Door Test ]Form Batts and Blankets When tnst&t50 !n at cordon= with the mamfodureia r000mmerdations, Maui bat's mid blankets will provide the full R -vdue. R- Velum TO Obtain An Insviaeon resistance (R -Vdue) at maISTIMM R-30H0 R-30 R -2@ R -2X R -21140 R -19 R- D Minimum Thickness inarAbad phwd.snn should not be lass than 10.25' oe R -13 R -11 R-8 ^R-rtO'un a 5.S tacky. Cordons to Fedarel 5pedficeson W.4-521F. 10.00" 9.00° 5.50' 6.50" 6.25"' 3.50" 3.50" 3.50" 2.50" ASTM C065 sod Thermal Performance (Attic Application The etelud them* reactance (R.vaWe) is r.revided by lnekweg m geco:danoa with Oho ma1W°act ag /1091 c raps. tt>a rettilaad menber end of bass pier 1.000 94 or net area. at Not less than are Iata:ed mirdmum thickness. Facture t° instep bah the reeetrad name.-Of bags at Matt die t:rLdmtml INckeeee,Mll mat in tawerineule',.an firvatue. R -VeILLe To Obtain an insulation resistance 0-Value) of. Wei ilk Ba•st1.000s._+% I M- < urn .ver8•- OonUNS of ?Ice bag anotcd not The s"eL9wSF a* ire•llee weer more than: Ins legon ddd nonce a The rwmoor cf baydl O0b : rF Of not area 9Mu'.d not to 60 31.7 31.5 f 952 L8 R 45.3 SF 19.0 65! eS "• 52.7 SF -569 LBS .ea r nC tna!alled leattarlan shou'd gat betake 91a:x 14.76^ 13.00' 10.25' BIIMEMEMIMI 9.00" R -2fi 12.4 22 104 .28816$ 9.15° R -13 .152133 4.00" R-11 5.1 kiss requirements of AVM 0 764 Type I. sod Bag gilled t- moans s 30loso (HH4. m 2a Ice. This class 5. rR-V dues to the pereinn cancaHad FBOaralSwahr36an tit- t- t'iD30B.7yDa l dose 6. R- Vetuas me datarrPinad in arron]a(Ica vst+Gear arnd�� Ma. � Means resistance to heat flaw. The higher rte 11- vetua. the greeter the insulation sower. TO get the marked R.valos. • is Ts!atior. be Ostend properly. 1: you do it yourself. get inetlubtfons and fallout them care' idly 2009 Lr41SEC Residential Energy Compliance Cericificata - Building Air Leakage putidi 0 iz ieatConditl C.rnrner+ To aohle"a labeled lit-due. this product must tee applied ...Oh a pneumatic biowirg eled1019 and e opnagated r m• with a mtnernum 15" internal voeugaaan, a minimum ?Meth or 190 k eM a demeter of at least 5°. Co lle in thehme shoved nd be then36 Inaiernear. Aocoplable malarto', Seed rate is 5.35 fbeinen Se. rtecaramended feed nee 1016Z5eaJmerwre Butldere Insulation Statem6nt Batts andfor bunkers have bean hnsteaed in conformance wen die above recommendations to proeide a thermal resistance or... llama Builder Address: Affidavit: 80.9 F 0001 T;ms indoor Tempensase: ptgeoorTermpartu 51 Rom Areal (f!) - R• /slue ( Stands d R -49 R-38 pt-21 R -30 R- _I, R, 1 ,ed crawl SP3c0) 1404.x. R. R- fa WIL si J O 43 So. Insulation Northwest LLC P.O. Box 132069 Puyallup, WA 98373 Phone; (2S3) 846 -0121 u... MA-4t RdSAn96 in :trL Test g1 Depress Wass. Pretest Basercle atessubt___, (Pa) . __.. a cocci 1 Fan Press. 8109 Ras. (Fa)l Few Ring (pa) Post-Taet Pressur6 _. ON Cnn rlodeiSel Results: SLA ($peo5c Ltakese Test S2 Depress Press.j Pretest 0eseliha Pree91s"r (So) Row (elm) �E I..r NOV 16201 1 ci-OPAgY. Post -Test Pressure: . (Pa) Fen 0o0el13N`. Result9e StA (Spasms Leakage Aron):_ I certify that this Specific Leakage Area is 6ccurete and det_m,I+cd using Blower Door Test standard 502.4.5 Building AV Leaita0o Testing• /dame 'technician Signature City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANRIP Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers D12 -025 through DI2 -039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Je 'ferMar' e it echn File: Permit No. D12 -025 through D12 -039 W.\Permit Center \Extension Letters\Permits\2012\D12 -025 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 S.M. STEMPER F ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y 13 September 2012 Bill Rambo, Permit Technician City ofTukwila, Department of Comm unity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Rambo, This letter serves as written request to extend the permits listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RANRIP). Permit Address Permit Number Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 11666 42nd Ave S. D12 — 026 4604 S. 122nd St. D12 — 034 5003 S. 113th St. D12 — 027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036 5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12 — 037 11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D 12 — 039 12203 47th Ave S. D12 — 032 Permits for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original perm its. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 - 721 -0061 or tfenlason @onespayne.com. a, 6o lid / rtiilx4 1 die_ter 9/70°a /zal2 Timothy J. Fen lason Project Manager The Jones Payne Group, Inc. ALGE! v fiti ary OF TUKWILA Se 13 20121 PERMIT CENTER o1�lll�z P 4000 DELRIDGE WAY SW • SUITE 200 . SEATTLE, WA 98106 • 206/ 624 -2777 FAX206/ Q � 624 -2973 qk- 14\ 10 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -029 JACKSON RESIDENCE 5023 S 124 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall it Technician File: Permit File No. D12 -029 6300 Southcenter Boulevard, Suite # 100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -029 JACKSON RESIDENCE 5023 S 124 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, AmAjAU fer Mars) all it Techni ian File: Permit File No. D12 -029 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 ePteleomi .1f: A4 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -029 DATE: 02 -07 -12 PROJECT NAME: JACKSON RESIDENCE SITE ADDRESS: 5023 S 124 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPARTMENTS_ p__„ ulldin 'vision � 11°1 Public AO- 6rks Fire Prevention Structural Planning Division ❑ Permit Coordinator 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -09-12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: u APPROVALS OR CORRECTIONS: Approved 1 1 Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 03 -08-12 Not Approved (attach comments) ri Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 • • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI919OA Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 51,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 51,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO677C11 BID PACKAGE M -27 3- 53- 0058 -044 Lax lit PERMIT PEER�IT i` = QUiRED FOR: na NOV City of Tukwila Est NG DIVISION FILE COPY Permit No. Plan review approval is subject to errors and onVssions. A:^2; :-,vat of construction +•��'� documents does not gift ?eI'z9 thr. : a?lon of any adopted code or ordinance. Receipt a +proved Field Copy and conditions is acowledged: By Date: 3 /ZcIfty City Of lbkwila BUILDING DIVISION REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. '77: I )v:siorts will require a new 1 may include additional plan review fees. .tta! 1)1z- o2q REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 • City of Tukwila BUILDING DIVISION 14'7 ;1- Yi FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Seattle, WA APPLICABLE CODES: 2009 Seattle Residential Code, International Fire Code, International Mechanical Code 0119002285 LEGAL DESCRIPTION: ALLENTOWN ADD LESS SWLY 1/2 LOTS 9 4 10 ZONING: SF1200 OCCUPANCY: (No Charge) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v B NON SPRINKLERED DRAWING INDEX T0.0 41.0 A22 A2.I A22 423 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MI.O LEGENDS, SCHEDULES, ABBR Ev., GENERAL NOTES 4 DWG INDEX Mao MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County international Airport 1211 Perimeter Road South Seattle W.4 98108 Ph 206. 263. 9233 Fax: 206. 2%. 0190 Contact: Sharyn Parker E-mail: 5haryn.Parkerek1ngcounty.gov ARCHITECT: S.M. Stamper Architects PLL.C. 4000 Delridge Way 5W, Suite 200 Seattle, WA 98106 Ph 206. 624. 2111 Fax: 206. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerry•smstemper.com melodyesmetemper.com tlm•emetemper.com ACOUSTICAL ENGINEER 55A Acoustics 222 Etruria Street, Suite 100 Seattle WA 98103 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph 20b. 31S. 0569 Fax: 206.318.0641 Contact: Dylan Turner E -mail: DylanTegreenbuschcom ELECTRICAL ENGNEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: tin ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. '200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwell•Jonespayne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 58121 Ph: 206. 622. 4bsa Fax: 206.622.0422 Contact: Ron Martinson E -mail: rorxnepem- englneers.com ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REICISFRFD EVPEk 1 E 0` h. SHIN Or;, 0810.03.1938 9/20/11 0 0 J z 0 F- z w z i- z 0 0 z MPROVEMENTS 0 Cw w w V) 0 z H- Z AIP NUMBER 3 -53- 0058-044 z O F- 0 w DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1938 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS NCLUDING BUT NOT LIMITED TO: APPLICABLE YES N O 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WNDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. NFiLL OF EXISTING OPENINGS. v X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. NSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 38 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. b--1-2--0--a-7 X 14. INSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC NSULATION. X ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REICISFRFD EVPEk 1 E 0` h. SHIN Or;, 0810.03.1938 9/20/11 0 0 J z 0 F- z w z i- z 0 0 z MPROVEMENTS 0 Cw w w V) 0 z H- Z AIP NUMBER 3 -53- 0058-044 z O F- 0 w DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1938 LAUNDRY ROOM CLOSET BEDROOM 2 BEDROOM 3 CLOSET 24" x 24" EXIST. ATTIC ACCESS PANEL SPECIAL NOTES: NOTE: KNOB AND TUBE WIRING PRESENT. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING NOTES: 1. ASBESTOS CONTANNG MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE 'RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. b. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETU6EEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WNDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERFERE WITH (E) CLOSET SHELVNG, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO NTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FNISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13, INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET Ell, FOR LOCATIONS AND DETAILS OF NTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 A.M. 4 AFTER 5:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL. CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATNG, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 15. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW NSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FNISI-ES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. MAIN FLOOR PLAN 1/4" = 1' A. NORTH ELEVATION 12' -8" F. \ / 23' -9" / - - _I -- — — % H / I I, \ \ 11 11 11 11 11 11 L - .241-x 24" EXIST. ATTIC ACCESS. _ I .I . . PANEL. . . . R _ i - --I IR L.J r L- - - - = Y - - - - - - _-- - �- 1 r/ — \ �► 1 / / -- . 1 / / \ TYP. 'f I \ -/ - n - - - - - - - / RI 1 \ / B. EAST ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 0 DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR. REF. DOOR SCHEDULE. ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. ODEMOLISH EXISTING DOOR(5), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON 51-1EET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE NTERIOR HARDWARE SET. QINSTALL VENT SAFFLE(5) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 4/A22 FOR DETAIL. 0 INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. ATTIC PLAN C. SOUTH ELEVATION altlt REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION D. WEST ELEVATION LEGEND A w 01404 L •1 I Ir Ib• • • u �. O SCHEDULE ACOUSTICAL DOOR NCIZEMPTO DOOR SCHEDULE •�•: i •' "•AkEI-I. A2.1 SEPRI 191 '1 5 STORM wit.156prifitre TO DOOR SCHEDULE FLCIESP6EtairIMIIIILE NIA#I:C.HENi EXHAUST ELECTRICAL PANEL ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. FREMION1trikekiaLliiITREF. MECH. FOR UNIT. PHOTO DETAIL VENT BAFFLE EXTERIOR ELEVATION PHOTO VIEW j 1 GABLE END VENT BAFFLE NOT USED RIDGE VENT BAFFLE FEB 07 ZO RM1T GEN FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL EMOLITION FOR ATTIC PANEL E HOUSE VENT NSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 FIE Willa SD INSTALL BATTERY OPERATED SMOKE DETECTORS III KITCHEN EXHAUST BAFFLE NOT USED GAS METER kpokMECHANICAL DUCTING 2 EP • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 vTT )9 i Eh:?PE rTC C, +f WINGED: 0810.03.1938 9/20/11 O 0 ce J Q z 0 I- Q z w 1— z z 0 U 00 z AIP NUMBER MPROVEMENTS 5 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH FLOOR PLANS NOTES A1.0 0810.03.1938 WINDOW TYPES SLIDER 2 SINGLE HUNG OR DOUBLE HUNG WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE Wx H TRIM FINISH INT./ EXT. REMARKS DETAIL SET A LIVING ROOM 1 3' -11" x 3' -11" PAINT/PAINT 2/42.0 B BEDROOM I I 3' -S" x I' -9" PAINT/PAINT 2/A2.0 c BEDROOM I 1 2' -10" x 1' -II" PAINT/PAINT 1/42.0 D BEDROOM 2 1 2' -II" x 1' -10" PAINT/PAINT I/A2.0 E BEDROOM 2 1 3' -11" x 2' -10" PAINT/PAINT 1/A2.0 F BEDROOM 3 1 3' -11" x 2' -10" PAINT/PAINT SAFETY GLAZING REQUIRED 1/42.0 G BREAKFAST NOOK 1 2' -4" x 2' -I0" PAINT/PAINT SAFETY GLAZING REQUIRED VA2.0 H BREAKFAST NOOK 1 2' -5" x 2' -10" PAINT/PAINT 1/42.0 I KITCHEN 1 2' -5" x 2' -10" PAINT/PAINT 1/A2.0 J LIVING ROOM 2 2' -5" x 4' -0" PAINT/PAINT I/42.0 K LIVING ROOM I 3' -1I" x 3' -II" PAINT/PAINT 2 /A2.0 (E) = EXISTING TYPICAL WINDOW SCHEDULE NOTES 1 NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN NAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. (E) U. SIDING CARERJLLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SWEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY LID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST 51-EATHNG. NSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING WINDOW HEAD (E) GWB ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR NSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW JAMB u SOLID WOOD TRIM IUD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW SILL BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" (E) U. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING r 3 PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GUJ (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTNUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERI"IINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW A5$EM13LY CAREFULLY CUT BACK (E) IUD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT WINDOW HEAD LID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT NSULATION (E) GWB CONTNUOUS SEALANT, tYP. ACOUSTICAL WNPOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY SHIM AS NECESSARY FILL GAP W/ BATT INSULATION METAL PAN FLASHING PRE- PRIMED GALV. SILL PAN FLASHING - LAP JAMB FLASHING INTO SILL PAN. EMBED LAP N SEALANT. FIELD PAINT FLASHING - PAINT COLOR TO BE SELECTED N THE FIELD (E) BRICK VENEER WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION 4" //7/7/A rzA WINDOW SILL SEALANT 4 BACKER ROD 3/4" WD. SILL - PAINT TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. (E) GWB SELF- ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT AND (E) SILL PAN FLASHING. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) VNYL BACKSPLASH WOOD SIDING W BRICK VENEER - WINDOW DETAIL SET 3 "= 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION RF FEB 07 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 C 0. MINGTOI\ 0810.03.1938 9/20/11 I— W 0 a_ J z 0 I— z w z i- z 0 U 0 z AIP NUMBER MPROVEMENTS 0 Cw w w 0 z il 5 -53 -0058 -044 z O 0 z_ cn DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1938 DOOR TYPES 0 0 A B C FLUSH SCW FLUSH SCW EXTERIOR W/ FIVE PANELS W/ 3 PANELS SINGLE LEAF STORM W/ OBSERVATION PORT W/OBSERVATION PORT W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY A 3' -0" x 6' -8" STAN/STAIN HW -I 1 605 DK -2 (PLYMOUTH) LOCK -1 I /A2.1 2 DINING ROOM (INTERIOR) B 2' -&" x 6' -4" STAN /STAIN HUM / 605 DK -2 ( PLYMOUTH) 2 /A2.I 3 ENTRY C 3' -0" x b' -8" I /A2.1 TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING 15 INDICATED, BUT NOT SCHEDULED N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF NE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) U. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST 51-EAT1 -ING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP ,AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 1 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV 51-IEET METAL CAP FLASHING UNDER SELF - ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEI -IND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYR SOLID WOOD TRIM 51-1IM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND NSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING DOOR HEAD (E) EXTERIOR SHEATHING CONTINUOUS 97— SEALANT, TYP. EXISTING FRAMING CONTINUOUS SEALANT BEI-IND z BAR FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM TISI -IOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 "= 1' -0" 51-1IM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEW IN CONTNUOUS WEATW -ER STRIPPING SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING � 116.- SOLID WOOD TRIM w (E) X" GIB CONTINUOUS SEALANT, TYP. DOOR HEAD INTERIOR DOOR PER SCHEDULE KERF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD DOOR JAMB EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMNG CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM DOOR PER SCHEDULE INTERIOR - DOOR DETAIL SET 3 "= 1' -0" wcf REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 M1T • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 HEC!STERED WWI - ?P9>�PJ1P STATE 0= HING« 0810.03.1938 9/20/11 F- 0 J Z 0 Z w 1— Z 1— Z 0 U 0 Z AIP NUMBER MPROVEMENTS w w w 0 ce z C!1 5 -53 -0058 -044 0 1— Z DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1938 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF - ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF - ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 " =1' -0" INSULATION INSULATION DAM (E) WALL FRAMING (E) GWB ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS s 16" O.C. J -METAL EDGE AND CAULK JOINT DUCT SOFFIT DETAIL DEMOLISH (E) GLIB NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY D 1 1I2 "= 1' -0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE 14 !A 1 1 kV reVAWAVel WAWA relleeeNN CROSS SECTION EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2"X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 11/2" =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 • City of Tukwila BUILDING DIVISION FEB 07 2012 S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 `_''',S;(EPi D 'I LC 00TT EMPw TATS 0'= NCTCi< 0810.03.1938 9/20/11 0 11 >- J z Z H O w o z Z `t w try < w O LL Z I- 0 U < J Z Q w 0 U) w MPROVEMENTS AIP NUMBER 5 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH MISC. DETAILS A2.2 0810.03.1938 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 11 LAP SILL MEMBRANE FLASHING I -112" OVER (E) BLDG. PAPER AT SILL. EXTEND I in BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH R.O. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 1i" MIN Ki)MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. BUTTERFLY CORNER FLASHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANC3E IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT 51-1OULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE A7 WINDOW SILL (E) BLDG. PAPER AT SILL. 'I ' I '\ \ O O 4 o C , \\ 0 0 0 ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'R5 SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. WINDOW MEMBRANE INSTALLATION BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED EDGE OF (E) SIDING, 51H01IN D I AGRAMAT ICALLY. (E) SIDING NOT SHOWN FOR CLARITY. SCALE: NTS LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 51-1OU1N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. L WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLAMING AND WINDOW TRIM (FOLLOWING STEPS). J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER C2. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1R" BEYOND EDGE OF OPENING AT DEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT 5WOUk4 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. TYP. It INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. MEMBRANE FLASHING AT SILL �5 1 SCALE: NTS INSTALL 514T. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK PROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1/8" LEARANCE BETWEEN FL • ING AND BOT. EDGE • (E) SIDING. (E) BLDG. PAPER 9 HEAD FLASHING INSTALLATION ) SCALE: NTS CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1/2" BEYOND RO. AT HEAD AND JAMBS. i3 MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILNG FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET N PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 51- IOII1'. FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ET METAL HEAD LASHING E) SIDING E) BLDG. PAPER ATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. SCALE: NTS LEAVE I/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. C WINDOW FLASHING INSTALLATION SCALE: NTS b 0” REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 GIS'.' HER [4 COTT E,PE STATE 0 SNIbdGT O€. 9/20/11 0810.03.1938 i- ce O 0 J z 0 Q z w z z O U z MPROVEMENTS 0 ww w ce w U) 0 z LL ce AIP NUMBER 5 -53- 0058 -044 z 0 1- 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1938 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF READ RG RPM SA SEC SG SH T SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB w/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR a, 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT UNE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT U ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL $G -X XXX ABBE -1♦ I>< 411-I- 0 -� C7=1› EQUIP ID# oz NG • 0 D"4 A/ DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 <08"WG 7 "93 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 90 337 <08"WG 7 "93 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1938 1134 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. , ADDITION . EL, S LOCATE BRACKETS, HANGERS, ING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION. SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. b J, (Act MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) 4$ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1 /2) = 90 CFM FEB 07 2012 I' E° SEPARATE PEiiU i' AND APPROVAL. REQUIRE) 1 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRMGE WAY SW SUITE 200 • SEATTLE, WA 98108 (208) 824 -2777 • FAX (208) 824 -2073 THE GREENBUSCH GROUP, INC .•••S.•..I )) 100U87rA,. AIIOp_[ vcoo :ME 981 SFiGRE. WA NIlO (208) 378-0888 (208) 378 -0841 FAX CO C' C3) C; CO CD KING COUNTY INTERNATIONAL AIRPORT REMEDY IMPROVEMENTS RESIDENTIAL AIRCRAFT NOIS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1938 10' MIN. SEE GAS METER PENETRATE INTO CLOSET (E)SG BEDROOM 2 OUTSIDE AIR DUCT CONNECTS TO FURNACE IN ATTIC CLOSET 24' x 24' EXIST. ATTIC ACCESS PANEL BATH LOSET BEDROOM CHASE, DEFER TO ARCHITECTURAL (E)SG 1' w D LAUNDRY ROOM BEDROOM 3 (E)SG uL, (E)RG L CLOSET (E)SG MAIN FLOOR MECHANICAL PLAN LIVING ROOM BREAKFAST NOOK KITCHEN (E)SG SCALE: 1 /4" = 1' -0" OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING- FLOOR MOD, INTERLOCK TO FURNACE ATTIC (E)RETURN FURNACE POC CEILING (E)SUPPLY OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE IC e r v / r rr I, II I, 1 \ / I IL 24' x 24' EXIST. ATTIC ACCESS PANEL 7 "0 TYP ILI / / 7 "0 DN / II J / -I r 11 / I I El // 1 1 Lr 7 � i L_ ATTIC MECHANICAL PLAN / 1 / / / / / / \ J 1 SCALE: 1/4" = 1' -0" DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE NORTH DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. MODIFY EXISTING THERMOSTAT WITH TIMER SWITCH TO PROVIDE SEC 1412.4 COMPLIANCE. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. COORDINATE FINAL DUCT PENETRATION LOCATION AND REQUIRED SOFFIT WITH TECHNICAL REPRESENTATIVE. Seam PERMIT AND APPROVAL REQUIRED FEB 07 2012 T SITE 1 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Profeardonal Limited Liability Cemp.w 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (200) 624 -2777 • FAX (200) 024 -2973 THE GREENBUSCH GROUP, INC eta •l441.) ) . ialas VIDEO .1 EgOlEENNO 190o N(3! ST EET SATE 201 SE TIE. W 50119 (206) 370 -0609 (200) 370 -0041 FM 0810.03.1938 0 ct z 0 ct z w z z 0 0 C� Z MPROVEMENTS RESIDENTIAL AIRCRAFT NOISE REMEDY AIP NUMBER 3- 53- 0058-044 DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.1938 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. V PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WRING SPECIFICATIONS FOR SWITCH. eE��OOM ELECTRICAL LEGEND SY115OL DESCRIPTION SYMBOL DESCRIPTION sG. LIGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE 02 Am, 1/2°C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN 0 SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. THERMOSTAT CEIUNG MOUNTED FIRE ALARM - VISUAL STROBE LIGHT 0 UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR _ L \ E) °r FCOI°' CLsET :4, x M,4 EtIST. A TT •C > :.00ESS PANEL CLOSET TO RJRNACE DAI1 R NORTH 0— 5 E4KF{ ST ''1CC�K KITCHEN MAIN FLOOR PLAN 1/4" = 1' NECI- IAANICAL / ELECTRICAL COORD (NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH FEB 0 7 2012 EEPARATE APPRO RCq p ■ S.M,STEMPER ARCHITECTS A Professional Limited Liability Company- 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 • sN�IN�[•ea. INO MINI aux.s emu. MINI we MOM ...1.... MONNE OM 41111 0810.03.1938 AIP NUMBER MPROVEMENTS 0 w w w CO 0 z il 5-53- 0058 -043 SEATTLE WASHINGTON DATE 9/8/11 ISSUED M-27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1938