Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-032 - JIMERSON RESIDENCE - UPGRADES
JIMME]RSON RESIDENCE 12207 47 AV S D12 -032 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179001100 Address: 12207 47 AV S TUKW Suite No: Project Name: JIMERSON RESIDENCE DEVELOPMENT PERMIT Permit Number: D12-032 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: JIMERSON JOHNNY Address: 12203 47TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $25,274.00 Fees Collected: $993.76 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -032 Printed: 03 -20 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: lee C'ep This permit shall become null and voi if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: / ./6142-- PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC-7/10 D12 -032 Printed: 03 -20 -2012 this requirement. • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Thkwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -032 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://ivww.ci.tukwila.wa.us Building Pe `� o Mechanical Permit No. S Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12203 47th Avenue S. Tenant Name: Johnny Jimerson Property Owners Name: Johnny Jimerson Mailing Address: 12203 47th Avenue S. King Co Assessor's Tax No.: 0179001100 Suite Number: Floor: New Tenant: ❑ Yes ® .. No Tukwila WA 98178 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:Wpplications \Forms- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO. ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 25,274 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'•Applications'Forms- Applications On Line 2009 Applications', 1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 860 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'•Applications'Forms- Applications On Line 2009 Applications', 1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGE Signature: Print Name: Date: (p 12 i/.ACS D N Day Telephone: - 22-'7 -1- Mailing Address: Zip City State Date Application Accepted: Date Application Expires: Staff Initials: H:Wpplications \Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN•ERMIT INFORMATION — 206 -43 7 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Cod Occupancy (per Intl Building Code): Utility Purveyor: Water: ): Indicate type of plumbing fixtures and/or gas ; 'ping outlets being ewer: lied and the quantity below: Fixture Type: Qty Fixture Type: Qty ixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) �% ' Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals ;" J Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater an.,,(:r vent ' dustrial waste treatment i `•;- ceptor, including trap an.'•, ent, except for kitchen type �� .se interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or : teration of water ping and/or water trea , t equipment / Repair ► , alteration of drainage .'.vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 B.)/ flow protective ;r vice other than 'atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow prate `�, e device other than atmosp ":. -c -type vacuum breakers ov= �. inch (51 mm) diamete'`., Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) f' j Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H: Appiications' :Forms- Applications On- Line2009 Applications`] -2009 Permit Application.doc Revised: 1 -2009 bb Page 5 of 6 Clip of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: RI2 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17,659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION RECORD Retain a copy with permit INSPECTIO N0. EMIT N0. CITY OF TUKWILA BUILDING DIVISION, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proje'a t"`R _elf Type { Uspexign: e NN .�� Addr s. r - AUk...,- Date Called: Special Instructions: 1 Z -i 0 3 Date Wante . :. I ,. Requester: PhOngNo • Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 11\15 A can &fA6E lnsp ctor: o ,t Data: REINSPECTION FEE EQUIR . Prio to next inspection, fee t paid at 6300 Southcenter Blvd., Suite 1bo. Call to scfiaduts reinsp INSPECTION NO. INSPECTION RECORD Retain a copy with permit .1)/2 --03 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,yZ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Prot; fti7C ?SOA/ of Inspection: , fie,.. Address: /..07 5'7 Au S Date Called: /2L ©3 -/7 Av S Special Instructions: Date Wanted: .iD (<3 - /_5 12 -- p.m. Requester: Phone No: 5-'5'5 - 347 - 2? ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS:_,) 4 0 6.1 92 /iv'', -~ 4,p /c't%d' /1).0"rth4 eri/ 13-,/,#),-7. .4/FffieZ i.)/,)s-Ia, '4 —/ NO i f: Lid ?4'61 4,24)af S s / S /2L ©3 -/7 Av S Date: -/3- /7 SPECTION FEE REQUIRED. Prior to next inspection, fee must be id at 6300 Southcenter Btvd.. Suite 100. Call to schedule reinspection. `GU 7-10- Nun 1 ago _T'); NORTHWST PERto Insulation Certific2fe / Blower Door Test Form 1)$(2.- • ■ Insulation Northwest LLC Batts and Blankets When installed in accordance with the manufacturer's recommendations, Knauf hams and blankets will provide the full R- value. R- Value Minimum Thickness Td Obtain An insulation resistance (R- Value) oh Installed insulation should not be less than: R -38HD 10.25" R -38 12.00" R -30HD 8.25" 9-30 10.00" R -26 9.00" R -22 6.50" R -21HD 5.50" R -19 6.25 "" R -15HD 3.50" R -13 3.50" R -11 3.50" R -8 2.50" ^R -18 in a 5.5" cavity. Con orms to ASTM C665 and Federal Specification HP- I -521F. Thermal Performance (Attic Application) The stated thermal resistance (9- value) is provided by installing in accordance with the manufactuers instructions, the required number of bags per 1,000 sq.ft. of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness will result in ower insulation R- value. R- Value Bags /1,000 s . ft. The number of bags /1,000 SF of net area should not be Maximum Coverage Contents of this bag should not cover more than: Minimum Weight The weight/SF of installed insulation should not be less than: Minimum Thickness Installed insulation should not be less than: To Obtain en insulation resistance (R- Value) of: R -60 31.7 31.5 SF .952 LBS R- 19.75" R-49 25.8 38.7 SF .774 LBS gv@ So. 16.75" R -44 22.1 45.3 SF .663 LBS Address: 14.75" R -38 19.0 52.7 SF .569 LBS Phone: (253) 846 -0121 13.00" R -30 14.4 69.7 SF .431 LBS 10.25" R -26 12.4 80.9 SF .371 LBS 9.00" R -22 10 4 95.8 SF .313 LBS 7.75" R -19 8 9 111.8 SF .268 LBS 6.75" R -13 6.1 164.3 SF .183 LBS 4.75" R -11 5.1 197.6 SF .152 LBS I 4.00" Bag Weight - Nominal 30 lbs., Minimum 29 lbs. This product conforms to the performance requirements of ASTM C 764, Type 1, and cancelled Federal Specification HH- I- 10308, Type I, Class B. R- Values are determined in accordance with C 687 and C 518. " "R" means resistance to heat flow. The higher the R- value, the greater the insulation power. To get the marked R- value, it is eseential that the insulation be installed properly. If you do it yourself, get instructions and follow them carefully. To achieve labeled R- value, this product must be applied with a pneumatic blowing machine and a corrugated hose with a minimum 25" internal corrugation, a minimum length of 150 ft and a diameter of at least 3'. Coils in the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 lbs. /minute. Recommended feed rate is 15-25 lbs. /minute. Builders Insulation Statement Batts and/or blankets have been installed in conformance with the above recommendations to provide a thermal resistance of... 20091NSEC Residential Energy Compliance Certificate - Building Air Leakage Building & Test Condition Comments Date: Time: Indoor Temperature: Outdoor Temmperature: Floor Area (fb) Affidavit: Building Air Leakage Target: SLA Less than 0.00030 Test ii1 Depress ._ Press ._ Pretest Baseline Pressure:_ (Pa) Bldg Press. (Pa) R -Value Standard Attic Area • I R- 38 R-49 Sloped Ceilings R- R -38 Walls R- R -21 Floors (over an unheated crawl space) R- I R -30 Completed as of: /G,' ao gv@ So. ^f Site Address: /•UOJ -� `�h f I&14//4. Ai, a/19 Home Builder Signature: Home Builder Address: Insulation Contractor: Insulation Northwest LLC P.O. Box 732069 Puyallup, WA 98373 Phone: (253) 846 -0121 Fax: (253) 846 -8096 Affidavit: Building Air Leakage Target: SLA Less than 0.00030 Test ii1 Depress ._ Press ._ Pretest Baseline Pressure:_ (Pa) Bldg Press. (Pa) Flow Ring Fa `Pa)ss. Flow (cfm) Post -Test Pressure: . (Pa) Fan Model /SN: Results: SLA (Specific Leakage Area): Test #2 Depress .. Press._ Pretest Base:ine Pressure: ,(Pa) Bldg Press. (Pa) Flow Ring Fan(Pu)ss. Flow (cfm) Post -Test Pressure: . (Pa) Fan .U.odel /SN: Results: SLA (Specific Leakage Area): I certify that this Specific Leakage Area is accurate and determined using Blower Door Test Standard 502.4.5 Bui:ding Air Leakage Testing Name Technician Signature / 0.9 S EA. ,Lj d 6 due, Pow .s )/54. ii; oTYL) r/e 4,- 4 L dr av✓f JG}/, r4 (-61(c' 08 -01 -2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -032 JIMERSON RESIDENCE 12207 47 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, A File: Permit File No. D12 -032 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 P 111 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -032 DATE: 02 -07 -12 PROJECT NAME: JIMERSON RESIDENCE SITE ADDRESS: 12203 47 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bttiltlfng" Division (11i ilic Wdrr 411c)-- A-w‘ Fire Prevention In Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 02 -09-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route TI Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -08-12 Approved ❑ Approved with Conditions XI Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 e 4) General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT FILE COPY Permit No.. _ Plan lroview approval is subject to snore and or*** Approval of construction documents does not authcR2e the violation of any adopted code or ordinance. Receipt of approved Field Copy and =Ions is acknowledged: By_. tI2 city Ibkvilla BUILDING DIVISION RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27 3- 53- 0058 -044 SEPARATE PERMIT RE'Q'UIRED FOR: Mebbanica! Electrical Plumbing Gas Piping City of Tukwi a Emil # i G DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may in„'ude additional plan review fess. Dim 032 FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 0119001100 LEGAL DESCRIPTION: ALLENTOWN ADD ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v 5 NON SPRINKLERED REVIEWED FOR CODE COMPLiANCE APPROVED FEB 15 2012 City of kwila BUILDING IVISiON DRAWING INDEX T0.0 410 A2.0 A2.I A2.2 42.3 TITLE SHEET, PROJECT INFO. FLOOR PLANS i NOTES WINDOW TYPES, SCI.1EDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MID LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX r12.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph 206. 263. 9233 Fax: 206. 296. 0190 Contact: 5haryn Parker E -mail: Sharyn.Parkerekingcountygov ARCHITECT: S.M. Stamper Architects PLLCC. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryesmstemper.com melodyesmstemper.com timesmatemper com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206.833 0819 Fax: 206. an 0824 Contact: Mohamed Alt Allaoua E -mail: mohameedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph 206. 318. 0569 Fax: 206. 318. 0641 Contact: Dylan Turner E -ma11: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenapbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwellejonespaynecom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepsm- engineers.com i S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 /i_ 'C rEC Tr STATE 1)= 0810.03.2029 9/20/11 il- 0 0_ Lt J z 0 z w I-- z >- F- z O U z AIP NUMBER EMPE HING i CPS; MPROVEMENTS >- 0 Cw w rt w 0 z H LL U J F- z w (0 t� w 3- 53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2029 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOILN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X S. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X S. INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AiR UNIT AND ASSOCIATED DUCTING. X 9.B INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. y X 14. INSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC INSULATION. X i S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 /i_ 'C rEC Tr STATE 1)= 0810.03.2029 9/20/11 il- 0 0_ Lt J z 0 z w I-- z >- F- z O U z AIP NUMBER EMPE HING i CPS; MPROVEMENTS >- 0 Cw w rt w 0 z H LL U J F- z w (0 t� w 3- 53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2029 14" x 40" EXIST. FA ATTIC ACCESS PANEL SPECIAL NOTES: NOTES: I. ASBESTOS CONTAINING MATERIALS ARE PRESENT At THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO WAVE ACM PRESENT PRIOR TO START OF WORK MD WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PANT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. GENERAL NOTES 1. CONTRACTOR TO PROTECT OUNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL WAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8 :00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 8 :00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WNDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. a ALL WORK AREAS SHALL BE BROOM- CLEANED AT NE END OF EACH WORK DAY. . PANELS, DUCTS t SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDNATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WIN (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WIN SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. IL DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FNISNES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET £0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF NTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WNDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS PCUER MUST BE PROVIDED AT RESIDENCE BEFORE S :00 AM. 4 AFTER 5:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 13. EXISTING WNDOW COVERINGS MUST BE RENSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WNDOW COVERINGS MUST BE PROVIDED. A MAIN FLOOR PLAN 1/4" = 1' A. EAST ELEVATION r 1 N J SOUTH ELEVATION P Ip - - ° -_ - -- - - - - - - 1 I BI DI flI _ E-T-._. ffI I' - -1. - 1 I .. - _I - - - 11" x 40" EXIST. ATTIC-ACCESS - PANEL C� 36'-6" ATTIC PLAN 1/4" = 1' C. WEST ELEVATION PLAN KEYNOTES c:: DEMOLISH (E) WINDOW, CASNG AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXIStNG DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. O DOOR SCHEDULE. 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. 0 BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 3/A22 FOR DETAIL. 0 COORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. O INSTALL VENT BAFFLE(S) At EXISTING ROOF VENTS) N ATTIC, REF. 4/A22 FOR DETAIL 0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDNATE. MECHANICAL AND ELECTRICAL DOCUMENTS. 0 INSTALL NEW ELECTRICAL SERVICE MD ELECTRICAL PANEL. REF: ELECTRICAL DOCUMENTS. ACCESS TO SITE AND PARKING I. NE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. (E) SOFFIT VENT, TYI. D. NORTH ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION LEGEND E9 [xi eta A A\ ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR NTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW GABLE END VENT BAFFLE RIDGE VENT BAFFLE RECEIV ` C FEB 07 20 2 PERMIT f BEN ER FEATHER TEXTURED CEILING OVER AT A : i MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PANT J ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. :.R,a REF. MEOW. 4 ELECT. :: -,i REF. GENERAL NOTE 11 ATTIC INSULATION SD INSTALL BATTERY OPERATED SMOKE DETECTORS l 'ell wAel KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTNG bLO32 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAx (206) 624 -2973 RFDSTEPED 0810.03.2029 E.11P;. SHINGTOI\ 9/20/11 F- 0 a_ J z 0 F- z w F- z FF- z 0 0 0 z AIP NUMBER C/) F- z W W 0 0 D W w w 0 z v 3 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2029 WINDOW TYPES CASEMENT / FIXED / CASEMENT 2. SLIDER 3. SINGLE HUNG OR DOUBLE HUNG 4 FIXED I CASEMENT WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A LIVING 1 7' -2" x 4' -10" STAIN /PAINT 1 /A2.0 B DINING 2 3' -9" x 3' -9" STAIN /PAINT 2/A2.0 C KITCHEN 3 2' -6" x 3' -4" STAIN /PAINT 2/A2.0 D BEDROOM 1 4 3'- 10 "x2' -4" STAIN /PAINT 2/A2.0 E BEDROOM 1 2 3' -10" x 2' -4" STAIN /PAINT 2/A2.0 F BEDROOM 2 2 3' -10" x 2' -4" STAIN /PAINT 2 /A2.0 G BEDROOM 2 4 3' -10" x 2' -4" STAIN /PAINT 2 /A2.0 H BEDROOM 3 2 3' -10" x 2' -4" STAIN /PAINT 2 /A2.0 (E) U. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING CRANE AGAINST SMEATHNG. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SWEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED SACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER DADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING WINDOW HEAD II SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION - (E) GUS fCONTINUOUS SEALANT, TYP. BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WNDOW NAILNG FN WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP WI BATT INSULATION BACKER ROD 4 SEALANT 3/4" 3/4" WD. SILL - STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE WI NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHNG (E) WD SIDING WINDOW SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF - ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PANT TO MATCH (E) SIDING (E) GIIJB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) T -111 SIDING TO ALLOW FOR REATTACHMENT TO RD. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -III SIDING WINDOW HEAD SOLID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD I SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE WINDOW JAMB (E) GUS WD JAMB LINING SEALANT SWIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -III SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE WI NEW SIDING AS REQ'D TO MAINTAIN COURSING I PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING C WINDOW SILL BACKER ROD I SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERING MEMBRANE (E) GWIB T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. FEB 07 2012 `E p1)- o32 ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2029 9/20/11 F- O I_ J z 0 F- z r:e w F- z F- z O U 0 AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 Z 0 f.5 F C9 z DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2029 DOOR TYPES FLUSH 8011 WI WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT 8 EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET /FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING A 3' -0" x 6-7" PAINT /PAINT HW -1/626 DK -4 (PLYMOUTH) LOCK -1 1/A2.1 2 KITCHEN B 2' -8" x 6' -8" PAINT /PAINT HW -1/626 DK -4 (PLYMOUTH) LOCK -1 1/A2.1 3 LIVING A 3-0" x 6' -7" 1/A2.1 4 KITCHEN B 2' -8" x 6' -8" 1/A2.1 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF-ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL CAP FLASHNG UNDER SELF - ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MN. (E) EXTERIOR SHEATHING SELF- ADHERING MEMBRANE CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR JAMB HARDWOOD JAMS BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. �� DOOR SWEEP ALUMINUM THRESHOLD "� `I ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR SILL CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BAIT NSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPNG INSTALLATION CONTINUOUS WEATIaER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FRAMING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR! EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 =w E,TETi D A —HITEC' GOTT ,R MPE S" /qr. ?- THING CIS: 0810.03.2029 9/20/11 F- O 0 J z 0 w F- z F- z 0 U 0 z AIP NUMBER MPROVEMENTS w w w 0 z H U Q J Q H Z W D W 3 -53 -0058 -044 0 F- 0 z DATE 9!20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2029 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. At HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PANT TO MATCH (E) SIDING PRE - PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF- ADHERING MEMBRANE. EXTEND -� FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN NE FIELD PAINT VENTILATION FIXTURE, COLOR TO SE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. j III (E) WALL UNDERLAYMENT SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" Hi EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS REVIEWED FOR CODE COMPLIANCE APPRO E:1 FEB 15 2012 City of Tukwila BUILDING DIVISION SUSPEND MECH UNIT FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL (D BLENDING AIR UNIT DETAIL 11/2 " =1' -0" ii INSULATION DAM DETAIL INSULATION INSULATION DAM (E) WALL FRAMING 3 " =1' -0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE EXISTING VENT COVER CROSS SECTION NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1 1/2" = 1' - 0" FEB 07 2012 TER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2029 9/20/11 0 a. J z Q w p O O r o w Z CW Q w 0 Z J LI- Z P U 0 w U < C9 J Z w w MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2029 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOUJ FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 i" BEYOND RD. AT EA END OF SILL. (E) BLDG. RAPER AT SILL (E) SHEATHING CUT SILL FLASHING t FOLD THROUGH RO. AS SWIM. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING Ii" MIN MEMBRANE FLASHING AT SILL k 5" k BUTTERI: Y CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. Ct I D 1 O 0 O O p O 0 O O 0 O N MEMBRANE FLASHING PREVIOUSLY APPLIED TO WNDOW OPENINGS. BEND ANCHORAGE NAILS DOWN >. OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: NSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION (E) SHEATHING SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. Ir (E) SIDING I, NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHORN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1 /S" LEARANCE BETWEEN FL ING AND 13OT. EDGE ►' (E) SIDING. C9 HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RD. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (--; MEMBRANE FLASHING AT JAMB SCALE: NTS 10 WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6 AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "S AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND OR NSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 10 CE b1�- -032 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 FR,-GG E E 0810.03.2029 9/20/11 0 0 F- a J Z Z L1J H Z Z 0 U G7 AIP NUMBER MPROVEMENTS 0 w ce w w 0 ce z Z to 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2029 \NN 10 WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6 AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "S AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND OR NSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 10 CE b1�- -032 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 FR,-GG E E 0810.03.2029 9/20/11 0 0 F- a J Z Z L1J H Z Z 0 U G7 AIP NUMBER MPROVEMENTS 0 w ce w w 0 ce z Z to 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2029 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CON T COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW H WC H WG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP VP VD VTR W WB WI WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLON S GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL R AC> OR XX 0 X/Y / / / / / / / //, DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITE' •, : • •N EEL, - " e' _ - t HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX AWE S. s -NI- N- I- 0 0 -> 0 N- � DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT WI INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEIUNG SUPPLY GRILLE CEIUNG RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH OR Q THERMOSTAT EQUIP ID \ EQUIPMENT LOCATION NG • 0 A MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS 120 DESCRIPTION VOLTS PH .5 WG NOTE: 1. COORDINATE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. 8" CEILING 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS 32 "Lx12.25 "Wx8.5 "H ELECTRICAL COMMENTS 1, 2, 3 WATTS 76 VOLTS 120 PHASE 1 BV -1 165 .5 WG NOTE: 1. COORDINATE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # _ REMARKS 3 SG -1 165 <.08" WG 8» 8" CEILING ALGRILLE 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <08" WG 4" 4" CEILING DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2029 888 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEIUNG SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. SWITCH HOURS OF OPERATION SET SWITCH TO OPERATE 1 OF EVERY 2 HOURS. D 032 MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = OR / (&EGR X F) QR = (FROM TABLE 403.8.1) 4_,1 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION ]. QF = 45 / (1 X 1 /2) = 90 CFM FEB 07 2012 IT CENTFj EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) e24 -2777 • PA! (20e) e24 -2973 THE GREENBUSCH GROUP, INC .■••••••. )) ,coI IDg. VmEO tan . E�IOEE F1WNa ,EEO WEST MJOp tan sot 86Un.r. Wd 2611E (206) 37e -06e9 (20e) 37e -0641 FM 0810.03..2029 TIONAL AIRPORT z W z KING COUNTY cn H z w w 0 a 0 wrJ ce w w O z Q W w ce AIP NUMBER 3 -53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2029 I EXPIRES: 9/08/2012 I GAS METER (E)SG (E)RG DINING / SEE TYP CEILING GRILLES L I VING ROOM (E)SG ALL KI TCNEN (E)SG BATH 165 TO BLENDING UNIT TYP BEDROOM 1 RG -1 25 E SG N BEDROOM 3 (E)SG O 25 E)ACCESS LEAK O RG -1 25 BEDROOM 2 MIAN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS RETURN AIR DUCT OUTSIDE AIR DUCT 16" MIN FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE BV -1 USE ENLARGED ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS ATTIC NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL SCALE: NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE r L DUCT PER PLAN II II II II I I L__ --J G 8 "0 DN TO SG -1 r I L 1 r 4 "0 DN TO RG -1 1 -� C 8 ] „0 TO SWITCH 'y--- SEE ATTIC MECHANICAL PLAN 7" 1 OG -1 90 SEE v 4 "0 DN TO RG -1 II II (E)ACCESS I I u 4 "O 'DN TO RG -1 L J J SCALE: 1/4" = 1' -0" CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE NORTH DUCT PER PLAN TYP COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL SCALE: NONE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51- 52- 0403.8.3. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE WALL AND MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FEB 07 2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 88108 (206) 624 -2777 • ?AX (206) 624 -29721 THE GREENBUSCH GROUP, INC eelle■•••••)) Coug r NaIYIOID_/ v9)E10 d I IL B OlNO 1109 9EST Mii.�50 I SHEET S EE 201 SERE, W 99119 (206) 370 -0009 (209) 370 -0941 FM 081 0.03.2029 F- O a Q z 0 ce z w H z z 0 v c� z RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3-53- 0058-044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2029 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT 'TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEIUNG AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. Q PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEIUNG OR WALL PENETRATION WORK. PROVIDE NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS if ROOF TRIM VEGETATION TO PROVIDE MINIMUM 36" CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW SERVICE DROP FROM POLE TO HOUSE BY SCL. ALL FEES PAID BY I CONTRACTOR. 2 "C, 3#3/O CU METER AND FINAL CONNECTIONS BY SCL INCLUDE ALL UTILITY CHARGES IN BID. PANEL MP 200A 120/240 1 -PH, 3W 2 "C, 33/0 CU.& GND PROVIDE METER BASE PER SCL STANDARD #DU13- 4 /NMT -30 PROVIDE #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND PRO DE NEW S.E. RA D PANEL BOARD. INTE CEPT AND EXTE D EXISTING CIRC TS AND CONNECT TO NEW BREA ERS. PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS PRIOR TO BID. NEW SERVICE DETAIL N.T.S. PROVIDE NEW WEATHER HEAD, MAST GUYS AND ANCHORS AT EXISTING LOCATION. PROVIDE NEW ROOF FLASHING. METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. ELECTRICAL LEGEND SYMBOL, DESCRIPTION SYM80L DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION WIRE, BKR DESCRIPTION LIGHTING OR POWER PANEL m EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 III 11 16 0 DAMPER CONNECTION D' NON- -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD 120 TOGGLE TYPE MOTOR DISCONNECT SWMTCH WITH THERMAL OVERLOADS - BRANCH CIRCUIT HOME RUN EXISTING LOAD EXISTING LOAD EXISTING LOAD SMOKE DETECTOR - EJ 5012 30/2 50/2 X ELECTRICAL METER 1,2 I TIMER OPERATED SWITCH 120 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. O THERMOSTAT - - - 4E CEILING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT A UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR 1" IECI- 4ANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION WIRE, BKR DESCRIPTION VOLTS PH 200 AMP with MAIN 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 1 3 5 7 9 11 EXISTING LOAD EXISTING LOAD EXISTING LOAD X 5012 30/2 50/2 X B B B 1,2 - SNITCHES (ON, TIMER) 120 1 13 X X 2011 A X 1 SPACE 14 15 EXISTING LOAD 20/1 B REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH NEW PANEL SEE PANEL SCHEDULE DEMO EXISTING PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL DIN LIB /INCA ROOM 5E ROOM K THEN L MAIN FLOOR PLAN 1/4" = 1' NORTH PANEL MP LOCATION: SERVING: 0810.03.2029 10,000 120/240 VOLT, 1 PHASE, 3 WIRE, BKR RESIDENCE NC, 200 AMP with MAIN CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 5 7 9 11 EXISTING LOAD EXISTING LOAD EXISTING LOAD 5012 30/2 50/2 A A A B B B 3012 1511 20/1 20/1 EXISTING LOAD EXISTING LOAD EXISTING LOAD BLENDING UNIT SPACE 2 4 6 8 10 12 13 EXISTING LOAD 2011 A SPACE 14 15 EXISTING LOAD 20/1 B SPACE 16 17 19 21 EXISTING LOAD PROVISION PROVISION 15/1 20/1 20/1 A A B SPACE SPACE _ SPACE 18 20 22 23 SPACE B SPACE 24 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS ® RAINTIGHT NEMA 3R ENCLOSURE [] DOUBLE LUGS ❑ MAIN BKR SHUNT TRIP SERVICE ENTRANCE LABEL PANEL SKIRTS ® SURFACE INTEGRAL TVSS ❑ FLUSH • ❑ • REMARKS: Dlj - -p32 FEB 07 2012 S e M,STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624- -2777 • FAX (206) 624 -2973 ■NOINUIRO, IMO U. wmo = marr, MI5 sel 4A.NIA. ■11 ri.iM MENNE EON MO ENO ewN+l.M I 0810.03.2029 H O a ce J Q Z Z 0 cc LLJ F- Z Z 0 U 0 Z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE 9/8/11 ISSUED M -27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 081 0.03.2029