HomeMy WebLinkAboutPermit D12-033 - DRAPER TUKWILA RESIDENCE - UPGRADESDRAPER TUKWILA
RESIDENCE
5009 S 112 ST
D12 -033
City olltukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 3348401751
Address: 5009 S 112 ST TUKW
Suite No:
Project Name: DRAPER TUKWILA RESIDENCE
Permit Number: D12-033
Issue Date: 03/20/2012
Permit Expires On: 09/16/2012
Owner:
Name: DRAPER TUKWILA L L C
Address: 2100 W COMMODORE WAY , SEATTLE WA 98199
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $41,371.00 Fees Collected: $1,387.12
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -033 Printed: 03 -20 -2012
•
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: O—t (— '"'�`9 Date:
Lee
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Print Name:
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D12 -033 Printed: 03 -20 -2012
this requirement.
0 i
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -033 Printed: 03 -20 -2012
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permt o.
Q i)- D33
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 5009 S. 112th St.
Tenant Name: Tukwila Draper LLC
Property Owners Name: Tukwila Draper LLC
Mailing Address: 5009 S. 112th St.
King Co Assessor's Tax No.: 3348401751
Suite Number: Floor:
New Tenant: ❑ Yes ® .. No
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Applications \Forms - Applications On Line \2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ' l'3 ION — 206- 431 -3670
Valuation of Project (contractor's bid price): $ 41,371 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H; Appiications'.Fotms- Applications On Linc2009 Applications . l -2009 - Permit Applicationdoc
Revised 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
950
2nd Floor
3'a Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H; Appiications'.Fotms- Applications On Linc2009 Applications . l -2009 - Permit Applicationdoc
Revised 1-2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZE I . _:,►: T:
Signature:
Print Name:
KricAer,DN
Date: Co RIO 17-
Day Telephone: Sob ' 62,`i -
Mailing Address:
City
State
Zip
Date Application Accepted:
Date Application Expires: Staff Initials:
H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bb
Page 6 of 6
PLUMBING AND GAS PIPIN •ERMIT INFORMATION — 206 -43.70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Expiration Date:
Building Use (per Intl Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
wer:
Indicate type of plumbing fixtures and/or gas piping outl being insta.' -d and the quantity below:
Fixture Type:
Qty
Fixture Type:
tan
..t ture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
lathes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
od -waste grinder,
co ^;mercial
Floor Drain
Shower, single head trap
Lavatory
r
Was fountain
Receptor, indirect waste
Sinks
Urinals
Water ' ,set
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or gent
Industrial w:ete treatment
interceptor, in 4, uding trap
and vent, excep' or kitchen
type grease inte : -.tors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair or a ation of
water pip'; 'g and/or water
treatme equipment
Repair or alteration 'f
drainage or vent pipi '
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Ba :' ow protective
d =•% ce other than
ospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective devic-
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:1Applications1Forms -App1k lions On- Llne2009 Applications'•.1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
Cif of Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http : //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R12 -00879
Initials: WER
Payment Date: 03/01/2012
User ID: 1655 Total Payment: 17,659.72
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED
SET TRANSACTIONS:
Set Member Amount
D12 -025
D12 -026
D12 -027
D12 -028
D12 -029
D12 -030
D12 -031
D12 -032
D12 -033
D12 -034
D12 -035
D12 -036
D12 -037
D12 -038
D12 -039
TOTAL:
993.76
1,313.36
1,313.36
1,042.93
993.76
1,239.61
1,411.70
993.76
1,387.12
1,165.85
811.18
905.73
1,460.87
1,190.44
1,436.29
993.76
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 17,659.72
TOTAL: 17,659.72
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 10,661.95
000.345.830 6,930.27
640.237.114 67.50
TOTAL: 17, 659.72
INSPECTION RECORD
Retain a copy with permit
, e 7, - 423
INSPECTION NO. PERMIT NO.c
CITY OF TUKWILA BUILDING DIVISION
6300 5outhcenter Blvd., #100, Tukwila. WA 98188 IC. (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
Project: j� /�. {
i ` 4 k Ra'ctJ F
Type Inspection: (
L3
!
. i 6' 4
i N AA. .i
Cddress.
..c c)1
I r 2 3T-
Date Called:
Special Instructions:
Date Wanted 3
-.(`S
- { ...-.
a.m.
•..
Requester:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
efiki ro44 k
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must he
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule `reins pectit>h:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
bf2 - os
Project:
AR 4 4472
Type of Inspection:
,c ' .v'9 L.
Address:
.5dO 6 1/2
$1
Date Called:
/71 y ✓b-V, Pi / 7 Y141 ` 1 iiffFr%n
Special Instructions:
f
Date Wanted:.
�' -.. < 3 —i2
-
p.m.
Requester:
Phone li
r
Approved per applicable codes. ll Corrections required prior to approval.
COMMENTS: p, 4
L A ? i,..1/6 -- , ;J, PF- 4t/'l/
/. ,'7;'i"`� rn
J✓; �✓' - Ii)
/71 y ✓b-V, Pi / 7 Y141 ` 1 iiffFr%n
r }
� -
6,, f. /r� r .)'4 j
f
pecto
L
SPECTION FEE REQUIRED. Prior to next inspection, fee must be
id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
:nsulatior. Northwest LLC
. .ti:c,, -- -10 -' �`� IN ,.,_, ,,_. Ili ii-\\ a _
�f
<?� r� O�UKVMIA
NOV 1 5 2012
Insulation Certificate I Cower Door Test Form
Batts and Blankets
When installed in accordance with the manufacturer's
recommendations, Knauf batts and blankets will provide
the full R- value.
PERMIT CENTER
Thermal Performance (Attic Application)
The stated thermal resistance (R- value) is provided by installing in accordance with the manuaactuers instructions, the required number of
nags per 1,000 sq.ft of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at
least the minimum thickness will result in lower insulation R- value.
R- Value'
Minimum Thickness
R- Value"
Baqs /1,000 sq. fL
Maximum Coverage
Minimum Weight
Minimum Thickness
To Obtain An insulation
resistance (R- Value) oh
Installed insulation should
not be less than:
To Obtain an insulation
resistance (R- Value) of.
The number of
bags /1 000 SF of net
area should not be
Contents of this bag should not
cover more than:
The weight/SF of installed
insulation should not be
less than:
Installed insulation should
not be less than:
R -38HD
10.25"
R -60
31.7
31.5 SF
.952 LBS
19.75"
R -38
12.00"
R-49
25.8
38.7 SF
.774 LBS
16.75"
R -30HD
8.25"
R-44
22.1
45.3 SF
.663 LBS
14.75"
R -30
10.00"
R -38
19.0
52.7 SF
.569 LBS
13 -00"
R -26
9.00"
R -30
14.4
69.7 SF
.431 LBS
10.25"
R -22
6.50"
R -26
12.4
80.9 SF
.371 LBS
9.00"
R -21 HD
5.50"
R -22
10.4
95.8 SF
.313 LBS
7.75"
R -19
6.25""
R -19
8.9
111.8 SF
.268 LBS
6 -75"
R -15HD
3.50"
R -13
6.1
164.3 SF
.183 LBS
4.75"
R -13
3.50"
R -11
5.1
197.6 SF
.152 LBS
4.00"
R -11
3.50"
Bag Weight - Nominal 30 lbs., Minimum 29 lbs. This product comfonns to the performance requirements of ASTM C 764, Type I, and
cancelled Federal Specification HH- I- 10306, Type I, Class B. R- Values are determined in accordance with C 687 and C 518. -'R" means
resistance to heat flow. The higher the R- value, the greater the insulation power. To get the marked R- value, it is eseential that the
insulation be installed properly. If you dot yourself, get instructions and follow them carefully.
R -8
2.50"
""R -18 in a 5 5" cavity. Con ores to ASTM C665 and
Federal Specification HH -I -521 F.
To achieve labeled R- value, this product must be applied with a pneumatic blowing machine and a
corrugated hose with a minimum .25' internal corrugation, a minimum length of 150 ft and a diameter
of at least 3 ". Coils in the hose should not be less than 36" in diameter. Acceptable material feed
rate is 5-35 lbs. /minute. Recommended feed rate is 15.25 lbs. / minule.
Builders Insulation Statement
Batts and/or blankets have been installed in conformance with the above recommendations to
provide a thermal resistance of...
2009 WSEC Residential Energy Compliance
Certificate - Building Air Leakage
Building & Test Condition Comments
Date:
Time:
Indoor Temperature:
Outdoor Tennper ature:
Floor Area (fib)
Affidavit:
Building Air Leakage Target: SLA Less than 0.00030
Test #1
Depress ._ Press ._
Pretest Baseline Pressure:_ (Pa)
Bldg Press. (Pal
Flow Ring
Fan Press.
(Pa)
Flow (efm)
Post -Test Pressure: . (Pa)
Fan Model /SN:
Results:
SLA (Specific Leakage Area):
Test #2
Depress. - Press._
Pretest Baseline pressure: . (Pa)
Bldg Press. (Pa)
Flow Ring
Fan Press.
(Pa)
Flow (cfm)
Post -Test Pressure: . (Pa)
Fan Model/SR:
Results:
SLA (Specific Leakage Area):
1712 -033
I certify that this Specfic Leakage Area is accurate and determined using Blower Door Test Standard 502.4.5 Building Air Leakage Testing.
Name
Technician Signa :ure
R -Value
Standard
Attic Area
R- 3 d'
R-49
Sloped Ceilings
R.
R-38 .
Walls
R.
R -21
Floors (over an unheated crawl space)
R-
I
R -30
Completed as of: %AZ
` �/
/ /./45J•
Site Address: 5019 5a.
Home Builder
Signature:
Home Builder
Address:
Insulation
Contractor: Insulation Northwest LLC
P.O. Box 732069
Puyallup, WA 98373
Phone: (253) 846 -0121
Fax: (253) 846 -8096
Affidavit:
Building Air Leakage Target: SLA Less than 0.00030
Test #1
Depress ._ Press ._
Pretest Baseline Pressure:_ (Pa)
Bldg Press. (Pal
Flow Ring
Fan Press.
(Pa)
Flow (efm)
Post -Test Pressure: . (Pa)
Fan Model /SN:
Results:
SLA (Specific Leakage Area):
Test #2
Depress. - Press._
Pretest Baseline pressure: . (Pa)
Bldg Press. (Pa)
Flow Ring
Fan Press.
(Pa)
Flow (cfm)
Post -Test Pressure: . (Pa)
Fan Model/SR:
Results:
SLA (Specific Leakage Area):
1712 -033
I certify that this Specfic Leakage Area is accurate and determined using Blower Door Test Standard 502.4.5 Building Air Leakage Testing.
Name
Technician Signa :ure
08 -01 -2012
City of Tukwila
Department of Community Development
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -033
DRAPER TUKWILA RESIDENCE
5009 S 112 ST TUKW
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 09/16/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
File: Permit File No. D12 -033
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665
•
PLAN R "VIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -033 DATE: 02 -07 -12
PROJECT NAME: TUKWILA DRAPER RESIDENCE
SITE ADDRESS: 5009 S 112 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
'vision
Public Works
t2
AMA-
Fire Prevention Planning Division
Structural
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
14,
Incomplete
n
DUE DATE: 02-09 -12
Not Applicable
1
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
Structural Review Required
No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03 -08-12
Approved Approved with Conditions Kr Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
•
S
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.00
03/06/2012
3
Landmark American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Printaspx
03/20/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO677C11 BID PACKAGE M -27
3- 53- 0058 -044
FILE COPY
Permit No., A)11-
ple.n review approval is eject to Mrs and omissions.
t ppro',al of consbuction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and coaions is acknowledged:
By /- l
Data: -7( aG //2
City Of Ibicwila
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR:
kg Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
Bt.M..D,NC DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
F visions will require a new plan submittal
and may include additional plan review fees.
bLI- 033
T�{
FEB 07 2012
VICINITY MAP (NTS)
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
3348401151
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV *2 N W FT
ZONING: SF 1200
OCCUPANCY: (No Chance)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of ' u
BUILDING
Ha
VISION
DRAWING INDEX
T00
AI.0
A2.0
A2.1
A22
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MID LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS
M2.I MECHANICAL DETAILS
M22 KEY TO BLENDING UNIT ZONES
EIPJ ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY NIL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98105
Ph 206. 263. S233
Fax: 206.296.0190
Contact: Sharyn Parker
E -mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stamper Architects PL.LCC.
4000 Delrides Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmstemper.com
timesmstemper.com
ACOUSTICAL ENGINEER
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 95109
Ph: 206. S39. 0819
Fax: 206.839.0524
Contact: Mohamed Ait Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 056S
Fax: 206.315.0641
Contact: Dylan Turner
E -mail: DylanTegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 95102
Ph: 206. 232. S63S
Fax: 206.162. 4150
Contact: Tim Ogden
E -mail: tim ogden•pbbenvcom
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washinnggton St. •00
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwelleJonespayne.com
STRUCTURAL ENGINEER
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4550
Fax: 206.622.0422
Contact: Ron Martinson
E-mail: ronmepsm- engineers.com
SCOPE OF WORK
i ENOVATiON OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
11-1E CONTRACT ALL NFORMATiON IN NE DRAWNGS AND
MECHANICAL VENTILATION.
SPECIFICATIONS INCLUDING BUT NOT LIMITED
APPLICABLE
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING STORM DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
a. INSTALLATION OF PET DOORS.
X
SA INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
9.B INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
12. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
13. INSTALLATION OF CHIMNEY CAP.
X
14. INSTALLATION OF SMOKE DETECTORS.
X
15. REGULATED MATERIALS ABATEMENT.
X
16. ATTIC VENT BAFFLES.
X
11. INSTALLATION OF ATTIC INSULATION.
X
S.M .STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
• ,..trpolf
TEMPE
II'v% O Pv
9/20/11
0810.03.2031
F-
ce
O
ce
z
0
F-
Q
z
w
F-
z
F-
z
0
0
V
z
MPROVEMENTS
0
w
ce
w
w
O
z
U
D
AIP NUMBER
3 -53- 0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
L B & SW
PROJECT
INFORMATION,
DRAWING
VICINITY MAP
DIRECTORY
T0.0
0810.03.2031
Pa ine.0
SPECIAL NOTES:
NOTE:
KNOB AND TUBE WIRING PRESENT.
NOTE:
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
BASEMENT PLAN
1/4" = 1'
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. I- IOMEOWNERS WILL WAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WOW DAY.
9. PANELS, DUCTS I SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POIIER OUTAGE IS EIGHT HOURS. POII,ER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 88.00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY NSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WNDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERNGS ARE
NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
A. NORTH ELEVATION
14" x 14" EXIST.
ATTIC ACCESS
PANEL
B. EAST ELEVATION
REVIEWED FOR 1
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUI LDING DIVISION
MAIN FLOOR PLAN
1/4" = 1'
PLAN KEYNOTES
O DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF.
® DOOR SCHEDULE.
O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
0 DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, AND CASING REF. DOOR SCHEDULE.
O INSTALL SECONDARY SLIDING GLASS DOOR REF. A2.1 FOR DOOR SCHEDULE.
O BLENDING MIT IN ATTIC INSTALLED ADJACENT TO ATTIC ACCESS PANEL, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL
AND DISCONNECT. REF.4 /A22 FOR DETAIL.
-I BLENDING UNIT INSTALLED IN GARAGE HELD TIGHT TO (E) STRUCTURE, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND
DISCONNECT. REF. 4/A22 FOR DETAIL.
S COORDINATE WALL GRILL WITH MECHANICAL DOCUMENTS. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA REF. MECH. FOR
INSTALLATION DETAIL.
0 COORDINATE CEILING: GRILL WITH MECHANICAL DOCUMENTS.
10 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS.
11 INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) IN ATTIC, REF. 5/A22 FOR DETAIL.
12 NSTALL VENT BAFFLES) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 6/A22 FOR DETAIL.
13 SURPLUS EXISTING WINDOW TO HOMEOWNER
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
10' -3"
C. SOUTH ELEVATION
25' -5"
1
Nk
_
I
L_ -_ - -ATTIC ACCESS
- -PANEL
4'
i
\
FI1 7� 1 \
Lam-- �-
26' -2" -
L - -J
ATTIC PLAN
1/4" = 1'
i
RECEA, D
FEB 07 2012
PERMIT CENTER
LEGEND
EY
AN
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO POOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO POOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE =GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
GABLE END VENT BAFFLE
RIDGE VENT BAFFLE
FEATHER TEXTURED CEILING OVER AT A
•
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
:
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
i AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
ATTIC INSULATION
INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
SOFFIT FOR MECHANICAL DUCTING
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
SIRED
'IIE.i
0810.03.2031
9/20/1 1
O
0
ce
z
O
z
w
F-
z
FF-
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
tt
w
w
w
0
z
D
C!1
3 -53- 0058 -044
z
0
F-
0
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
FLOOR
PLANS
NOTES
A1.0
0810.03.2031
WINDOW TYPES
SLIDER / FIXED / SLIDER
2.
SLIDER
3.
SINGLE HUNG
WINDOW SCHEDULE
WINDOW
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
REMARKS
DETAIL SET
A
LIVING
1
7' -11" x 3' -10"
STAIN /PAINT
1/A2.0
B
LIVING
2
1' -11" x 1' -10"
STAIN /PAINT
1/A2.0
C
LIVING
2
1' -11" x 1' -10"
STAIN /PAINT
1/A2.0
D
KITCHEN
2
2' -10" x 2' -10"
STAIN /PAINT
1/A2.0
E
KITCHEN
2
2' -10" x 2' -10"
STAIN /PAINT
1/A2.0
F
KITCHEN
2
5' -11" x 1' -11"
STAIN /PAINT
1 /A2.0
G
OFFICE
2
3' -10" x 3' -10"
STAIN /PAINT
1/A2.0
H
OFFICE
2
3' -10 "x 3' -10"
STAIN /PAINT
1/A2.0
I
KITCHEN
2
5' -11" x 2' -11"
STAIN /PAINT
1/A2.0
J
BEDROOM 1
2
5' -11" x 2' -11"
STAIN /PAINT
1/A2.0
K
BEDROOM 2
2
5' -10" x 2' -11"
STAIN /PAINT
1/A2.0
L
BEDROOM 2
2
5' -10" x 2' -11"
STAIN /PAINT
1/A2.0
M
LIVING
3
1' -10" x 3' -11"
STAIN /PAINT
1/A2.0
N
FAMILY ROOM
2
3' -6" x 1' -8"
STAIN /PAINT
2/A2.0
0
FAMILY ROOM
2
2' -3" x 1' -4"
STAIN /PAINT
2/A2.0
TYPICAL WINDOW SCHEDULE NOTES
1.
2.
3.
(E) Up. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGANST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDNG
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
CONTINUOUS
7 SEALANT, TYP.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMNED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF API•IERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHNG. INSTALL SECOND
LAYER OF SELF ADI -IERNG MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK TOOL
FLUSH, AND PANT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDNG FROM INSTALLATION OF
FLASHING
(E) W. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
WINDOW HEAD
I-
I -
0
0
,r
r1
LID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
- -(E) GdUB
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SWIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WINDOW JAMB
BACKER ROD I
SEALANT
3/4"
3/4" WD. SILL - STAIN TO
MATCH (E)
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAN
COURSING ! PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
LF- ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND
PANT TO MATCH (E) TRIM.
COLOR TO BE FIELD
DETERMINED
SELF - ADHERING
MEMBRANE
SEALANT AND BACKER
ROD
ACOUSTICAL
WINDOW ASSEMBLY.
CONTINUOUS
SEALANT, TYP.
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND
PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD
DETERMINED
SELF- ADHERING
MEMBRANE
SEALANT AND BACKER
ROD
ACOUSTICAL
WINDOW ASSEMBLY.
ACOUSTICAL
WINDOW ASSEMBLY.
TRIM- MATCH (E) TRIM. PRIME
ALL SIDES AND PAINT TO
MATCH (E) TRIM. COLOR TO
SE FIELD DETERMINED
F'Rk- F'FZIT'1kP, C,ALV b1-1 I
METAL FLASHING W/ F.F. ENG
CAPS UNDER SURFACE
MOUNTED REGLET AND CA'
FLASHING. PAINT COLOR TC
SELECTED IN THE FIELD
CONTINUOUS
SEALANT, TYP.
WINDOW HEAD
MLV
4
P.T. 2X BLOCKING FASTEN J
ANCHOR BOLTS (2 EACH 81
SOLID WOOD TRIM
WOOD JAMB LINING
SEALANT 4 BACKER ROD
EXISTING CMU WALL
(E) GWB
CONTINUOUS
SEALANT, TYP.
WINDOW JAMB
WINDOW SILL
CMU - WINDOW DETAIL SET
3 " =1' -0"
P.T. 2X BLOCKING FASTEN
ANCHOR BOLTS (2 EACH
SIDE)
SOLID WOOD TRIM
WOOD JAMB LINING
SEALANT I BACKER ROD
SEALANT t BACKER ROD
SOLID WOOD SILL
P.T. 2X BLOCKING
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
REVIEW]
CODE COMPLIANCE
a PPPO'fED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
FEB 07 2012
PERMITCENTER
D« -o33
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REDSTE E-J
0810.03.2031
9/20/11
Et'
O
a-
J
z
0
�---
Q
z
W
F-
z
Z
0
U
z
AIP NUMBER
MPROVEMENTS
0
w
w
w
0
z
H
U
H-
z
W
Cn
3 -53- 0058 -044
z
0
F-
0
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2031
DOOR TYPES
III
O
O
A
FLUSH SCW
W/ RECTANGLE LITE AND
4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
FLUSH SCW
W/ FIVE PANELS
tU/ OBSERVATION PORT
C
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH INT. /EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK SET
DETAIL SET
1
LIVING
A
3' -0" x 6' -8"
PAINT /PAINT
HW -1/626
DK -4
(ADDISON)
LOCK -1
1/A2.1
2
KITCHEN (INTERIOR)
A
3' -0" x 6' -6"
PAINT /PAINT
HW -1/626
DK -1
LOCK -1
3/A2.1
3
OFFICE (INTERIOR)
B
2' -6" x 6' -8"
PAINT /PAINT
HW -1/626
DK -1
LOCK -1
3/A2.1
4
LIVING
C
2' -8" x 6' -8"
PAINT /PAINT
�
i
Itt*T0=011
2/A2.1
5
FAMILY ROOM
A
3' -0" x 6' -7"
PAINT /PAINT
HW -1/626
DK -1
LOCK -1
1/A2.1
6
LIVING
D
3' -0" x 6' -8"
REMOVE (E) WOOD SIDING AS REQ'D �
I TRIM. REPLACE W/ NEW S DING I PA Nt fI
1/A2.1
7
FAMILY ROOM
D
3' -0" x 6' -7"
CONtINU0U5 WEATHER
STRIPPING
KEW M CONTINUOUS
-
TO MATCH (E) SIDING
�i
-1
1/A2.1
l E1 WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF
SELF - ADHERING MEMBRANE AGAINST
SHEATHING. ExTEND SELF - ADHERING
I
PRE - PRIMED, GALV SHEET METAL GAP'
FLASHING UNDER SELF - ADHERING
MEMBRANE. PAINT DOLOR t0 BE
SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR `
FRAME
II .:7
���
��I�
I!I(
KERF AS REQUIRED FOR
ATH ST I I
WEATHER
ALL
CONTINUOUS WEATHER-
.r
WI =AtHER &TRIPPING
DOOR
HEAD
INSTALLATION OF FLASHING AND DDOR
''
II
�I
HEAD ASSEMBLY ;
�!I
1
��•
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT At-
ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT
CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS
SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
(E) IUD. SIDING
(E) WD. SIDING
&HIM AS NECESSARY
FILL GAP W/ GATT
(E) "
I
I
CAREFULLY LIFT (E) WALL UNDERLAYMENt I
AND INSTALL TOP EDGE OF SELF- ADHERNG I
MEMBRANE AGAINST SHEATHING. LAP (E)
`� -_ ..i
SELF- ADHERING
,
..
1I
_ ,,,,
GWB
CONTINUOUS
SEALANT, tYP.
PRE- PRIMED, GAL/ SHEET METAL CAP
k„,___
(E) WALL UNDERLAYMENT
INSULATION
MEMBRANE
(E) EXTERIOR SHEATHING
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING h�P'�RANE. tYP AT HEAD
MD JAMB '�
Ii:
II
II'
i�
°'r�
11%
FLASHING UNDER SELF- ADHERING
MEMBRANE. PAINT COLOR TO BE SELECTED
`� ��
(E) EXTERIOR SHEATHING
BACKER ROD AND SEALANT
SOLID WOOD TRIM
F
gill
01
�;'...
IN THE FIELD
SELF - ADHERING MEMBRANE. TURN DOWN
I
[
GONTNUOUS
SEALANT, 7YP.
._ --
�
i
Itt*T0=011
I
WOOD FRAME
SUI�ACE APPLIED
f
' `[
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE I& VISIBLE BELOW
"��
„�,`
SOLID WOOD TRIM
INTERIOR DOOR PER
SCHEDULE
-
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
.
City of Tukwila
Dl.;[LC} [ [iI G DIVISION
FRAMING
1.
r
SELF- ADHERING MEMBRANE
REMOVE (E) WOOD SIDING AND
REPLACE AS P.Q'D. CAREFULLY LIFT
� -w
REMOVE (E) WOOD SIDING AS REQ'D �
I TRIM. REPLACE W/ NEW S DING I PA Nt fI
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP WI BATT
INSULATION
WOOD FRAME
FLASHING EDGE
-
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
■
■
�'
!'
I
I
_.:i.-
CONtINU0U5 WEATHER
STRIPPING
KEW M CONTINUOUS
-
TO MATCH (E) SIDING
�i
-1
`
l E1 WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF
SELF - ADHERING MEMBRANE AGAINST
SHEATHING. ExTEND SELF - ADHERING
I
PRE - PRIMED, GALV SHEET METAL GAP'
FLASHING UNDER SELF - ADHERING
MEMBRANE. PAINT DOLOR t0 BE
SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR `
FRAME
II .:7
���
��I�
I!I(
KERF AS REQUIRED FOR
ATH ST I I
WEATHER
ALL
CONTINUOUS WEATHER-
.r
WI =AtHER &TRIPPING
DOOR
HEAD
INSTALLATION OF FLASHING AND DDOR
''
II
�I
HEAD ASSEMBLY ;
�!I
1
��•
-�
MEMBRANE 4 UP WALL FROM TOP OF
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP. AT
HEAD AND JAMB
TRIM- PANT TO MATCH (E) TRIM II'
'i•
r WI
0,
��rril�
A
I
STRIPPING
SCHEDULE
CONTINUOUS 2x SOLID BLOCKING /%.
STORM SCHEDULE
'
DOOR PER
MIN.
HEAD
DOOR PER
AROUND PERIMETER OF DOOR FRAME.
PANT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM p••-
G
(E) PRIMARY SLIDING DOOR
2"
DOOR
CAREFULLY CUT BACK (E) WD. SIDING TO
I.
u
111
11
u
1
I
„ -w
_
'
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) BLDG. PAPER
DOOR
HEAD
I"
ASSEMBLY.
ALLOW L� Ems. TNT INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADI-IERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENt. CAULK
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP N SIDING
FROM INSTALLATION OF FLASHING
�
I
I
�°`� -
( r l _.__
(- -^' ° --
"- -- - --- -
-
`
(E)
SHIM AS NECESSARY
EXISTING
CONTINUOUS
SEALANT,
FILL GAP WI BATT
INSULATION
'
BACKER ROD AND SEALANT
SELF- ADHEARING MEMBRANE
BACKER ROD AND SEALANT
SOLID WOOD TRIM
.:
NI
SOLID WOOD TRIM
(E) BEVELED X. SIDING
A
ito
PLYWOOD
r.
_ -
(E) EXTERIOR SHF-
WOOD FRAME
SURFACE APPLIED
ill O , 1'
�i
�4THING
r.
>-
(E) WOOD SIDING
EXTERIOR SHEATHING
— CONTINUOUS
/
DOOR PER SCHEDULE
�`t`��
I.
PRE- PRIMED, GALV SHEET METAL"
FLASHING UNDER SELF - ADHERING
`LIFT
:::: r
(E) WALL UNDERLAYMENt.
LAP NEW UNDERLAYMENt UNDER
��
/
SEALANT, TYP.
FRAMING
CONTINUOUS WEATHER
STRIPPING
KERF IN CONTINUOUS
DOOR
V
JAMB
G MtH FI SELE TED E ELD ..
MEMBRANE. PAINT COLOR TO BE Foo
2x SOLID AROUND
- --
(E) UNDERLAYI~IENT 2" AND
CONTINUE DYER SLIDING GLA&5
EXISTING
DOOR FRAME
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM SCHEDULE
CONTINUOUS BLOCKING
PERIMETER OF DOOR FRAME. PANT ALL
EXPOSED EDGE& TO MATCW (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
I...
WEATHER &TRIPPING
.
_:
j
.r,
,1�11� I
���.�i
SOLID WOOD TRIM
SWIM AS NECESSARY
I SU GAP W/ BATT
INSULATION
SC HEDULE
,
POOR PER
��
j
((
I (
SELF- ADHERING MEMBRANE
11,
—
KERF AS REQUIRED FOR WEATHER IIIMR
SECONDARY SLIDING STORM
STRIPPING INSTALLATION
," MIN.
DOOR PER
DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
CONTINUOUS WEATHER- STRIPPING
DOOR
JAMB
CsLASSMDASLIDING OOR
i" MIN.
AND
GLASS
DOOR
BETWEEN
SECONDARY
DOOR
FRAMES
JAMB
PRIMARY
SLIDING
HARDWOOD JAMB BEYOND
lE) SLIDING GLASS
DOOR
WOOD DOOR PER SCHEDULE
WD. TRIM BEYOND
DOOR SHOE
-.-
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
2" MIN.
1C
''
I`
+"
Ilr±
1
(I' "
(E) FINISH FLOOR
—
—
�.
[,
1-
(E) WO. FLOOR CFRAMING
DOOR SWEEP
0
"!
JAMB BEYOND
WOOD DOOR
—f
ALUMINUM THRESHOLD
ADJUSTABLE &WEEP '�
irJ't�
LE
`-��r
r +
DOOR SHOE
AUTOMATIC SWEEP
SEALANT
EXISTING FLOOR STRUCTURE
�✓
(E) FLOOR/ FRAMING
/
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
DOOR
OR
411'
ALUMINUM THRESHOLD
DECK
DOOR
WOOD SIDING
/ \
-
SILL
DOOR DETAIL SET
1111114alliMAZ
EXISTING FLOOR STRUCTURE
DOOR SILL
C3) INTERIOR -DOOR DETAIL SET
3 -1 -0 b t ).......
3 -1 -fl
3 -1 -0
0
FEB 0 7 2012
t !`t CENTE
033
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
_OTT_ ?EMPE,
TATE n ` 4i _FIN(;IO
0810.03.2031
9/20/11
F-
0
0
J
z
0
F—
z
w
F—
I—
z
z
0
0
z
AIP NUMBER
MPROVEMENTS
3 -53- 0058 -044
z
0
I-
z_
Q
H
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2031
CARERILLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF - ADHERING
MEMBRANE. TIP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE - PRIMED, GALV. SHEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF- ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR TO
BE SELECTED IN THE FIELD
PAINT VENTILATION FIXTUiv,
COLOR TO BE SELECTED N
NE FIELD
II
VI
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
EXTERIOR VENTILATION FIXTURE
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
2X2 CONTINUOUS PRESSURE
TREATED BLOCKNG, 4 SIDES
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
3 "= 1' -0"
(E) 2X10 • I6" O.C.
(E) GWB
BLENDING AIR UNIT DETAIL
3" = 1" - 0"
(E) ATTIC
DUCT
CHASE
ANCHOR CEILING NAILER
TO (E) RESILIENT
CHANNEL ONLY. DO NOT
ANCHOR TO JOIST
WHERE WIDTH OF SOFFIT
EXCEEDS I6 ", INSTALL 2X4
STUDS • 16" O.C.
J -METAL EDGE AND
CAULK JOINT
DUCT SOFFIT DETAIL
1112 " =1' -0"
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
DISPLACE (E) INSULATION
TO FACILITATE INSTALLATION
OF MECHANICAL UNIT, DUCTS
AND ACCESS HATCH
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
INSULATION STOP AT
PERIMETER OF ACCESS
HATCH OPENING, 4 SIDES -
2x up BLOCKING
DEMOLISH (E) GLOB
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D TO ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL BE CUT FULL SIZE
OF SOFFIT AREA, TYPICAL
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
2x2 CONT. NAILER
5/S" GWB- PAINT TO MATCH (E) TEXTURE 4
COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE W/ ADJ. ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL
(E) WO FRAME WALL ASSEMBLY
INSULATION DAM DETAIL
3 " =1' -0"
INSULATION
INSULATION DAM
(E) WALL FRAMNG
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2"X SPACER
LATERAL SECTION
ROOF VENT BAFFLE
3 " =1' -0"
6" MN. TYPICAL TOP 4
BOTTOM
NEW I" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
EXIST. WALL
CONSTR
INSTALL 2X BLOCKING
AROUND OPENING AND
FASTEN EDGES OF
DRYWALL TO BLOCKING.
ASSUME (E) CEILING
JOISTS • 24" 0.0. EXTEND
BLOCKING TO (E) CEILING
JOISTS (TYP)
(E) GWB
SNAP FRICTION CATCH
REMOVABLE DOOR
PAINT DOOR AND FRAME
TO MATCH (E) COLOR OF
CEILING
ATTIC HATCH DETAIL
3" =1' -0"
(2) SIMPSON A -34 • EACH SIDE
PANEL TO SECURE VENT BAFFLE TO
(E) WALL FRAMING
OPEN TOP
EXIST. GABLE
VENT
NEW }" GALV.
HARDWARE
CLOTH
i" CDX PLYWOOD
AT (3) SIDES
I" OWENS CORNING 41103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
L AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
GABLE END VENT BAFFLE
1 1/2" = 1' - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
bao33
FEB 07 2012
CENTS-:`,
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
4 ?20
CGS
SAT[
0810.03.2031
9/20/11
F-
CC
0
0
Et
J z
Q ju O
0 r C�
Lu z
W
Cn Q
W 0
z
§-
z I-
0
U <
0 J
Z
W
W
MPROVEMENTS
AIP NUMBER
3- 53- 0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
MISC.
DETAILS
A2.2
0810.03.2031
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHNG AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLY AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I I"
BEYOND RA. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHNG 4 FOLD
THROUGH R.O. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
I" MIN
MEMBRANE FLASHING AT SILL
Jr 5 J(
BUTTERFLY COMER FLASHNG
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHORN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
REMOVED
77- \
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
IIANDOW
OPENINGS.
SEND
ANCHORAGE
NAILS DOUJ1
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW `=
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
8 SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
L
HEAD FLASHING PREPARATION
J
WHERE RE
(E) BLDG
HEAD TO
FOR INSTA
HEAD FL
WINDOW TR
(FOLLOW
(E) SHEATHING
IRKED, TRIM
APER AT
PARE
LATION OF
NG AND
STEPS).
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) R,O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -I/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
TRIMMED EDGE
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW I /S"
BETWEEN FL
DOT. EDGE
SIDING.
OF (E) SIDING,
SHOILN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RA. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS (BEEN INSTALLED.
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING,
� MEMBRANE FLASHING AT JAMB
Ki SCALE: NTS
Q
p
O
G
0
G
r
L 1
0 0 0
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
IIANDOW
OPENINGS.
SEND
ANCHORAGE
NAILS DOUJ1
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW `=
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
8 SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
L
HEAD FLASHING PREPARATION
J
WHERE RE
(E) BLDG
HEAD TO
FOR INSTA
HEAD FL
WINDOW TR
(FOLLOW
(E) SHEATHING
IRKED, TRIM
APER AT
PARE
LATION OF
NG AND
STEPS).
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) R,O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -I/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
TRIMMED EDGE
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW I /S"
BETWEEN FL
DOT. EDGE
SIDING.
OF (E) SIDING,
SHOILN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RA. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS (BEEN INSTALLED.
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING,
� MEMBRANE FLASHING AT JAMB
Ki SCALE: NTS
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "FEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "S AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 51 -10WN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
E) BLDG. PAPER
ATH SIDING
INSTALL U.D. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4 " -3/5" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
033
FEB 07 2012
MIrCENTE:::
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
:,-;n1 ill
COTT
0
E1'PE
- 6HIN(i vl\'
9/20/11
0810.03.2031
F'-
0
J
z
CD
_
CCz
w
F--
z
z
0
0
0
z
AIP NUMBER
MPROVEMENTS
0
w
W
w
F-
u_
F-
Z
0
ce
3 -53 -0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2031
r
L 1
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "FEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "S AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 51 -10WN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
E) BLDG. PAPER
ATH SIDING
INSTALL U.D. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4 " -3/5" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
033
FEB 07 2012
MIrCENTE:::
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
:,-;n1 ill
COTT
0
E1'PE
- 6HIN(i vl\'
9/20/11
0810.03.2031
F'-
0
J
z
CD
_
CCz
w
F--
z
z
0
0
0
z
AIP NUMBER
MPROVEMENTS
0
w
W
w
F-
u_
F-
Z
0
ce
3 -53 -0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2031
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASH RAE
BFC
BFF
BOD
BTUH
CD
CFM
CI RC
COND
CON T
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
H WS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEIUNG
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEIUNG
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR DESCRIPTION
XX
OR x,
0
X /Y
7/////////,
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT UNE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS
M2.1 MECHANICAL DETAILS
M2.2 KEY TO BLENDING UNIT ZONES
GENERAL NOTES
SYMBOL
SG —X
XXX
ABBR
-01— I-
0
O-�
0 t-
4
kj-
$
EQUIP ID #\..R �•_
IM
NG
•
D
0
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITE
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' —O" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
, HANGERS,
j1edetsc r. a I knot'? -79.(1,:•,/
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1,2
BLENDING UNIT VENTILATOR
120
1
X
6"
6"
X
ALGRILLE
1, 2, 3
X
90
1,2
—
SWITCHES (ON, TIMER)
120
1
1, 2, 3, 4
X
120
X
7"
7"
X
WALL CAP
1
RG -1
25
<08" WG
4"
4"
WALL
DECO
1, 2, 3
RG -2
25
<08" WG
4"
4"
REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
115
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
BV -2
170
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
1
SG -1
115
<08" WG
7"
7"
WALL
ALGRILLE
1, 2, 3
SG -2
95
<08" WG
7"
7"
CEILING
ALGRILLE
1, 2, 3
SG -3
75
<.08" WG
6"
6"
CEIUNG
ALGRILLE
1, 2, 3
OG -1
90
<08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
OG -2
120
<08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<08" WG
4"
4"
WALL
DECO
1, 2, 3
RG -2
25
<08" WG
4"
4"
CEIUNG
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2031 BV -1
175
1
90 CFM
90 CFM
1
0810.03.2031 BV -2
1921
2
120 CFM
120 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION I MIN VALUE 'NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3.
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
SWITCH HOURS OF OPERATION
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
SET BV -2 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION BV -1
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) IQ
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/3
QF = 30 / (1 X 1 /3) = 90 CFM
D «- 033
MECHANICAL VENTILATION CALCULATION BV -2
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) fQ
8&EGR = VENTILATION EFFECTIVENESS (EXCEPTION
F = FRACTION OF OPERATION 1/2
QF = 60 / (1 X 1 /2) = 120 CFM
IF SYSTEM OPERATES 1 OF EVERY ��UURS)= 1
•4A �M''i��T1igND
q��t1D�q�
FEB 07 2012
x^4d ar
•y(la :2:a g ei
U.$.
p'P
RE
S.M. STEMPER
ARCHITECTS
A Prote.don.1 Limited Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(800) 824 -2777 • FAX (200) 624 -2973
THE GREENBUSCH GROUP, 1NC
....S....
100 1113T1,_INId9_/ NOED • IE 2WlGL 0109�N0
1900 Sf N{7o91 A11 art 2*E 101 Sdg1LE w1 00119
(206) 378 -0009 (206) 370 -0041 FAX
0810.03.2031
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3-53- 0058-044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED
BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.2031
1
90
SEE
TYP
SEE
5
3
GARAGE
25
4 "0
115
BASEMENT MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
NORTH
SEE
TYP ALL
WALL GRILLES
OFFICE
KITCHEN
CHASE, REFER TO
ARCHITECTURAL
DRYER VENT
(E) VENT
L_ -1— I _��_._........ J
SAC _2
(E)EG
BATH
ATTIC ACCESS HATCH,
REFER TO ARCHITECTURAL
BEIDROOM
RG -2 '*
25 0
6 "0 DN
TO SG -3
95 O
TO BLENDING UNIT
LIVING
ROOM
SEE
CEILING GRI
BEL>ROOM
2
TYP ALL
_LES
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
SEE
r
rh-
\J]
[T1
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 3 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER WAC 51 -52- 0403.8.3.
FLAG NOTES:
131/-1. AND DUCTWORK ROUTED IN ATTIC.
COORDINATE ELECTRICAL AND MAINTENANCE
ACCESS HATCH WITH TECHNICAL
REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51- 52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET.
APPLY ACOUSTICAL DAMPING COMPOUND TO
INTERIOR FACES OF WALL CAP. COORDINATE
PAINT ON WALL CAP EXTERIOR FACES WITH
ARCHITECT. REFER TO ARCHITECTURAL
DRAWINGS AND TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
SHEET METAL "Y" FITTING W /VOL DAMPERS.
TYP
7 "0 DN
TO SG -2 C
TO SWITCH
7"
5
4 "0 DN
TO RG -2
P
(! `` 4 "0 DN
TO RG -2
0'33
NORTH
ATTIC MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
J
S.M. STEMPER
ARCHITECTS
A Profe.dond limited liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 96106
(20e) 824 -2777 • TAX (208) 824 -247
THE GREENBUSCH GROUP, INC
•.es.•
ACOUSTDL.
11211,22( & Am NC 1I0W 1Still.A1. 0I8W A 18119
( 6) Q
378 -0680 (206) 378 -0841 FAX
0810.03.2031
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3-53- 0058 -044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER.
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS
M2.0
0810.03.2031
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
16" MIN
HOLD TIGHT TO
STRUCTURE
FILTERS ACCESS
MOTOR ACCESS
USE ENLARGED ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE ACCESS
C
ATTIC
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
SCALE: NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLA
CAULK
FOAM BACKER
ROD
WALL
GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S
WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE INSTALLATION DETAIL
SCALE: NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1 /A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
SCALE: NONE
Cs)
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S
WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
SCALE: NONE
S.M. STEMPER
ARCHITECTS
A Professional Limited L1ab4IU Comp
4000 DELRIDGE WAY SW
SUITE 200 sEATPLE, WA 98108
(208) 624 -2777 • TAX (206) 824 -2973
THE GREENBUSCH GROUP, INC
mom)))
mow. 4,1101:0 161:0900(91. EOI EE INO
sEE SATE 101 MIME .M 0811.
(26)
378 -0660 (200) 376 -0041 FAX
633
FEB 07 2012
I EXPIRgE
0810.03.2031
KING COUNTY INTERNATIONAL AIRPORT
F-
w
rte'
0
z
F-
z
LU (,0)
U7 Q
o
z .cc
Et
a
LL �
J
z
w
w
AIP NUMBER
3 -53 -0058 -044
DATE
9/16/11
ISSUED
BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
DETAILS
M2.1
0810.03.2031
X
V` EP
X
Lxi
7
BASEMENT
MAIN FLOOR
b 11O33
FEB 07 2012
S.M. STEMPER
ARCHITECTS
A Protandonal limitati Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 9B106
(206) 624-2777 • FAX (206) 624-2673
THE GREENBUSCH GROUP, INC
111•0111■0 ill 00)))
#00USI1CAL. M / & IECHANDJ. BONEERINO
1KO 123T NOMON SMELT MITE 101 MOW. 111%
(206) 376-02166 (206) 376-0641 FM
0810.03.2031
KING COUNTY INTERNATIONAL AIRPORT
AIP NUMBER
3-53-0058-044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED BID PACKAGE M-27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
KEY TO
BLENDING
UNIT ZONES
M2.2
0810.03.2031
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM do AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
O PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
O HOME RUN CIRCUIT TO PANEL —MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL
CEILING OR WALL PENETRATION WORK.
O DISCONNECT EXISTING CONDUCTORS FROM EXISTING SINGLE —POLE NORMAL SIZE CIRCUIT BREAKER. REMOVE EXISTING
PROVIDE A 20/1 -20/1 HALF SIZE CIRCUIT BREAKER. CONNECT EXISTING LOAD AND NEW LOAD (BLENDING UNIT) TO
PROVIDE CONNECTIONS COMPLETE FOR EXISTING LOAD AND NEW LOAD.
REQUIREMENTS FOR ANY
CIRCUIT BREAKER.
NEW HALF SIZE BREAKER.
PANEL
MP
LOCATION:
SERVING:
0810.03.2031
S'OL
120 /240
VOLT,
1 PHASE, 3
WIRE.
BKR
RESIDENCE
10000
AMC,
200
AMP with MAIN
BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
III! 1'
15
16
DAMPER CONNECTION
Q'
NON —FUSED DISCONNECT SWITCH
CKT
LOAD DESCRIPTION
TYPE
KVA
1
PHASE
A/P
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
5
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
1,2
BV -2
2011 -20/1
20/1 -20/1
30/2
A
A
B
50/2
20/1 - 20/2 -20/1
— — —
E
EXISTING LOAD
EXISTING LOAD
2
4
6
7
X
1,2
—
SNITCHES (ON, TIMER)
B
1
X
8
9
11
13
15
17
19
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
X
30/2
20/1- 30/2 -20/1
20/1
20/1
A
A
A
B
B
B
2011 -20/2 -2011
20/1 -20/2 -20/1
40/2
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
10
12
14
16
18
20
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN, LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
0 ISOLATED GROUND BUS ❑ FEED THRU LUGS
0 RAINTIGHT NEMA -3R ENCLOSURE 0 DOUBLE LUGS
MAIN BKR SHUNT TRIP PANEL SKIRTS ❑ SURFACE
SERVICE ENTRANCE LABEL E INTEGRAL TVSS FLUSH
II
0
REMARKS:
=4IL ".
co
BASEMENT PLAN
1/4" = 1'
NORTH
ELECTRICAL_ LEGEND
SYMBOL
DESCRIPTION
S'OL
DESCRIPTION
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
G
UGHIING OR POWER PANEL
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
III! 1'
15
16
DAMPER CONNECTION
Q'
NON —FUSED DISCONNECT SWITCH
O
MAST, WEATHERHEAD
❑S'
TOGGLE TYPE MOTOR DISCONNECT SWITCI-I WITH THERMAL OVERLOADS
1
BRANCH CIRCUIT HOME RUN
®
SMOKE DETECTOR
--.--
ELECTRICAL METER
i
TIMER OPERATED SWITCH
1,2
BV -2
BLENDING UNIT VENTILATOR
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTIUTY.
®
THERMOSTAT
— — —
E
CI LUNG MOUNTED FIRE ALARM —VISUAL STROBE UGHT
0
LINE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
OFFICE
MECI-IAN ICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
BV -2
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
—
SNITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
_Ivls
MAIN FLOOR PLAN
bt),c43-•
1/4" = 1'
FEB 0 7 2012
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.2031
KING COUNTY
AIP NUMBER
MPROVEMENTS
0
w
oow
w
O
z
U
Q
J
Q
Z
W
D
W
5- 53- 0058 -043
Z
0
F-
0
co
2
DATE
918111
ISSUED M-27
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.2031