HomeMy WebLinkAboutPermit D12-034 - JOHNSON RESIDENCE - UPGRADESJOHNSON RESIDENCE 4604 S 122 ST D12 -034 Parcel No.: Address: Suite No: Project Name: City oPfukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 3347401415 4604 S 122 ST TUKW JOHNSON RESIDENCE DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D12 -034 03/20/2012 09/16/2012 Owner: Name: Address: JOHNSON JENNIFER L 4604 S 122ND ST , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $32,369.00 Type of Fire Protection: NONE Type of Construction: V -B Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $1,165.85 2009 0022 * *continued on next page ** doc: IBC -7/10 D12 -034 Printed: 03 -20 -2012 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All pro-visions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Led 6. . -6,0y7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. doc: IBC -7/10 D12-034 Printed: 03 -20 -2012 7: Remove all demolition rubble and loose llaneous material from lot or parcel of grou roperly cap the sanitary sewer connections, and properly fill or othe protect all basements, cellars, septic tanks, lls, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -034 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Pernu o. b «---tD ?)9 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 4604 S. 122nd St. King Co Assessor's Tax No.: 3347401415 Suite Number: Floor: Tenant Name: Jennifer L. Johnson New Tenant: ❑ Yes ® ..No Property Owners Name: Jennifer L. Johnson Mailing Address: 4604 S. 122nd St. Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Day Telephone: (206) 296 -7437 Mailing Address: 7277 Perimeter Road South Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Zip Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:Wpplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application,doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 32,369 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes J.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:' J{ ppIicationsForms. ApplicatiansOnLine‘2009Applicationn I- 2009 - Permit Application doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 1,730 2°d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:' J{ ppIicationsForms. ApplicatiansOnLine‘2009Applicationn I- 2009 - Permit Application doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE Signature: Print Name: L�J Date: ( Fek Z Day Telephone: ''O1ri -- (, -`� r 171 Mailing Address: City State Zip Date Application Accepted: Date Application Expires: ! Staff Initials: H:\Applications \Forms - Applications On Line\2009 Applications \l -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN®ERMIT INFORMATION — 206 -4370 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Build' Occupancy (per Int'l Building C Utility Purveyor: Water: Code): ). Expiration Date: Sewer: Indicate type of plumbing fixtures and/or g piping outlets b I g installed and the quantity below: Fixture Type: Qty Fixture Typ • ty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet �. �' \ Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain off,' water cooler (per h-;ra• Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals to `r. Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water hea ,.' and/or vent '�,, `, Industrial waste treatment interceptor, including trap ,. nd vent, except for kitchen `• .e grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) R- !':lr or alteration of w er piping and/or water ; eatment equipment R. *.. it or alteration of drail:. e or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow ■t,.tective device other than a.''Q spheric -type vacuum break-'`t.ver 2 inch (51 mm) di -ter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuu not included i , lawn sprinkler backfl protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets 5, H:•ApplicationsForms- Applications On- Line2009 Applications'.I -2009 Permit Application.doc kcvued: I-2009 bb Page 5 of 6 Ci f of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www, ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION RECORD Retain a copy with permit INSPECTIO iNO. PERMIT NO. CITY OF TUKWILA BUILDING D ISION (206) 431- 3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project. ' �1 A-J '1._ TYp 9f In �pe 'on: J ` 4 {� 1 �. Addrits:: 4 (o 0 1 t r� 1 C.2- ! - Date Called: . J t Special Instructions: Date Wanted; 1 " 1- p.m: Requester: Phone No: .. 5 -d 7 Approved per applicable codes. COMMENTS: 0 Corrections required prior to approval. Date:. REINSPECT1ONsEEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd,. Suite 100. Call to schedule reinspection: :11 ' i' J it v. -, iri 11,. IL ) ' r J PERT Batts and Blankets When installed in accordance with the manufacturer's recommendations, I<nauf bat's and blankets will provide the full 6- value. I. Insulation Certificate / Blower Door Test For iI R- Value" { Minimum Thickness To Obtain An irsulation Installed insulation should resistance (R- Value) of: not be less than: R -38HD R -38 R -301-ID R -30 R -26 R -22 R -21 H D R -19 R -15HD R -13 R -11 R -8 "R -18 in a 5.5" cavity. Conforms to Federal Specification HH- : -521F. 10.25" 12.00" 8.25" 10.00" 9.00" 6.50" 5.50" 6.25"" 3.50" 3.50" 3.50" 2.50" ASTM C665 and Insulation Northwest :..LC P Thermal Performance (Attic Application) The stated thermal resistance (R- value) is i rovided by installing in accordance with the manufactuers instructions, the required number of bags per 1,000 sq.R 0 net area, at not less than the iabeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness will result in 'ower insuiaticr. R- value. R- Value I Ba s /1.000 s . ft. I Maximum Coverage I Minimum Wei ht Minimum Thickness) To Obtain an insulation The number of 1 Contents of this bag should not The weight/SF of installed Installed insulation should l resistance (R- Value) or. tagsl1,000 : +F of net I not be area should ' r cover more than' I insuiaton should not be not be less then: less than: R -50 I I 31.5 SF I .952 LBS j 19.75" 774 LBS I 16.75" 1 45.3 SF 1 .663 LBS I 52.7 SF___� I 69.7 SF i\ 31.7 25.8 22.1 19.0 14.4 12.4 -10 4 a -`3 6.1 R-49 38.7 SF R-44 .569 LBS R -38 I .431 LBS R-30 I 80.9 SF .371 LBS R-26 I 95.8 SF .313 LBS R-19 I l .268 LBS I 111.8 SF _163 LBS R -13 I 164.3 SF R -13 .152 LBS I 4.00" R -11 I 5.1 197.6 SF Bag Weight - Nominal 30 lbs., Minimum 29 lbs. This product comform Type to the performance requirements of ASTM C 764, yp e 1, and cancelled Federal Specification HH- I- 10308, Type I, Class B. R- Values are determined in accordance with C 687 and Cn518.h" the means s resistance to heat flow. The higher the R- value, the greater the insulation power. To get the marked R- value, it insulation be installed properly. If you do it yourself, get instructions and follow them carefully. 2009 INSBC Residential Energy Compliance Certificate - Building Air Leakage 6uildina c Test Condition Comments 14.75" 13.00" 10.25" 9.00" 7.75" 6.75" 4.75" To achieve labeled R- value, this product must be applied with a pneumatic olowing machine and a corrugated hose with a minimum .25" intemal corrugation, a minimum length of 150 t anc a c•ameter of at least 3 ". Coils in the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 lbs. /minute. Recommended feed rate is 15-25 lbs. /minute. Date. Time: Indoor Temperature: Out000r Te Tennmperature: Builders Insulation Statement p a (re Batts and/or blankets have been installed in conformance witn the above recommeroatons to provide a thermal resistance of... 'Attic Area (Sloped Ceilings Walls Floors (over an unheated crawl space) Completed as of: Site Address: (Home Builder Signature: (Home Builder Address: I R. IR- IR- R -Value Standard R-49 R -38 R -21 R -30 «40 S. /o?2 ,d S< Bnildinfl Air Leaka?e Tora,et: SLA Less than 0.00030 Test r1 Depress Press._ Pretest Baseline Pressure:_ , . (Pa) Fan Press. Bldg Press. (Pa)i Flow Ring (Pal Post -Test Pressure: .(Pal Pan Model /SN: Results: SLA (Specific Leakage Area): Test #2 li Depress._ Press._ Pretest Baseline Pressure: (Pa) Flow (cfm) I Fan Press. Flow cfm Bldg Press. (Pall Plow Ring (pa) ( l Insulation (Contractor: insulation Northwest LLC Post -Test Pressure: . (Pa) P.O. Box 732069 Fan " ode:tSN:_ Puyallup, WA 98373 --I Phone: (253) 846 -0121 I Results: Fax: (253) 846 -8096 J SLA (Specific Leakage Areal: Affidavit: certdy that U`1is Specific Leakage Area is accurate ano determined us.rg B:cwer Door Test Standard 502.4.5 Buiiding A'r'_eakage Testing. Narr e T echnic,an Signature City of f Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANRIP Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers Dl 2 -025 through D12 -039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, .fer Mar • all echn ian File: Permit No. D12 -025 through D12 -039 W:\Pennit Center \Extension Letters \Permits\20I2 \D12 -025 Permit Extension doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 S.M. STEMPER ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y 13 September 2012 Bill Rambo, Permit Technician City of Tukwila, Department of Comm unity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Rambo, This letter serves as written request to extend the permits listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RAN RIP). Permit Address Permit N umber Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 1166642nd Ave S. D12 — 026 4604 S. 122nd St. D12 — 034 5003 S. 113th St. D12 — 027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036 5023 S. 124th St. D12 — 029 11822 42nd Ave S. D 12 —037 11602 40th Ave S. D12 — 030 12507 50th P1 S. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039 12203 47th Ave S. D12 — 032 Permits for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original permits. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 -721 -0061 or tfen lason @onespayne.com d4 Its - e'ti4714 cr/ze/zotz Sincerely, Timothy J. Fenlason Project Manager The Jones Payne Group, Inc. AELEa CITY OF OF TUKWILA UP 13 20121 PERMIT CENTER $uP o041117. 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 • 206/ 624 -2777 . FAX 206/ 624-2973 t\i6 417\ 11, 10 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -034 JOHNSON RESIDENCE 4604 S 122 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall it Technician File: Permit File No. D12 -034 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -034 JOHNSON RESIDENCE 4604 S 122 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, File: Permit File No. D12 -034 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 PLAN No -0 G SLIP ACTIVITY NUMBER: D12 -034 DATE: 02 -07 -12 PROJECT NAME: JOHNSON RESIDENCE SITE ADDRESS: 460i S 122 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued L DEPARTMENTS: w din 'vision Ay t- 2- -O- Public Wor s n 'NW - L cj Fire Prevention j Structural fl (VP_ iV/,1- -��1 -� Planning Division Permit Coordinator j DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 02-09 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire LI Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 141 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-08-12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentsfrouting slip doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.0003 /06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.0008 /05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT FILE COPY Permit No,, P12-- `/ \ Plan review approval Is subject fo errors and cessions. Approval of constructkm documents dies not authcriw9 the violation of any adopted code or ordinance. Recsipt of approved Field Copy and cordtbns is acknowledged: By, 1r- J327u.c'2' Date , ; 1`z City Of Itdcwita BUILDING DIVISION RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27 3- 53- 0058 -044 SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical tp Plumbing 11 Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341401415 I..EGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV • 1 11 4 W I/2 OF IS ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of !u 1 ila BUILDING ISION DRAWING INDEX TO.0 AI.0 A2.0 A2.I A22 42.3 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MUd LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS M2.1 MECHANICAL DETAILS M22 KEY TO BLENDING UNIT ZONES E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. S233 Fax: 206. 296. 0190 Contact: Sharyn Parker E -mail: 5ha ryn.Parkerekingcounty.gov ARCHITECT: S.M. Stamper Architects PLL.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 58106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: jerryesmstemper.com melodyesmetemper.com tlmesmstemper.c.om ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 95109 Ph: 206. S39.0819 Fax: 206.839.0524 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustice.com MECHANICAL ENGNEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Pit 206. 31S. 0669 Fax: 206.315.0641 Contact: Dylan Turner E-mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mall: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. S639 Fax: 206.162. 415o Contact: Tim Ogden E -mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 0200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwellejonespaynecom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepsm- engineers.com SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE VENTILATION. THE MECHANICAL L T NOT SPECIFICATIONS E TRACT INCLUDES ALL INFORMATION IN NE DRAWINGS AND APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WNDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. NSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X S. INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 9.8 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. X 14. NSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC INSULATION. X S.MSTEMPEft ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ;OTT F`'iiP' , 0810.03.2032 9/20/11 i- ce 0 a_ ce Q J z 0 ce W z F- 0 U z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 z 0 co Z_ 5 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2032 14" x 24" EXIST. ATTIC ACCESS PANEL MAIN FLOOR PLAN 1/4" = 1' GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. S. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO S:00 AM EACH DAY. HOMEOWNERS WILL WAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF .4 DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETUEEN S:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM- CLEANED AT NE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT 51-ELVNG SO AS NOT TO NTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT TINE PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EIS FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POUER OUTAGE IS EIGHT HOURS. POUTER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. 4 AFTER S.r.00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMER. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 15. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 6. 1 /'r.--.`, //1 ---� 114, -- - ,, � 1 1 /1 / �,"1 -, 111 1 U ' ° - -) 111 / // / I1.1 1--, „.7f/ Ic 1 } /r ° .6 1 f1 f// 1 I 1 11 111 f/ 1 11...24 " - x•24... %f 1 1 11-- •- -."txI T:. j-.'. 1 I,. -. "ATTIC" . .. f! / / 1, ACCE U / // 1 P / / l�- (� �� I1 11 I II )Ii / / 7 1 I lr r J \ . ....... . • EX. AiTaG IST ACCESS r % I i PANE/ 1I- al- \ =11 -i,� \i ATTIC PLAN 1/8" = 1' REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION PLAN KEYNOTES O DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. O DOOR SCHEDULE. O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. 0 COORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. O INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS. O INSTALL SECONDARY SLIDING GLASS DOOR. REF. A2.1 FOR DOOR SCHEDULE. OINSTALL VENT BAFFLE(5) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 5/A22 FOR DETAIL SO INSTALL VENT BAFFLES) AT EXISTING GABLE END VENT(5) IN ATTIC, REF. 6/A22 FOR DETAIL. O BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 4/422 FOR DETAIL. 10 SURPLUS EXISTING DOORS FOR HOMEOWNER 11 SURPLUS EXISTING WINDOW FOR HOMEOWNER. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 1 A. SOUTH ELEVATION B. WEST ELEVATION C. NORTH ELEVATION LEGEND E[y col A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR NTAKE GRILLE. REFER 1-0 MECH. FOR UNIT PHOTO PETAL EXTERIOR ELEVATION PHOTO VIEW D. EAST ELEVATION DO3Lf GABLE END VENT BAFFLE RIDGE VENT BAFFLE FEB 072 FEATHER TEXTURED CEILING OVER AT A : MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL i AND WHOLE HOUSE VENT INSTALLATION. J REF. MECH. 4 ELECT. <.:ij REF. GENERAL NOTE 11 ATTIC INSULATION SD INSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTING 12 ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 GIS ERE 0810.03.2032 9/20/11 i- ce 0 J z 0 Q z W z z 0 0 CD z AIP NUMBER MPROVEMENTS >- 0 w W W 0) 0 z iLL 0 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2032 SLIDER 2. SINGLE HUNG OR DOUBLE HUNG 3. CASEMENT WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A BEDROOM 1 1 4-11" x 3' -0" STAIN /PAINT 1 /A2.0 B BEDROOM 2 1 2' -11" x 3' -0" STAIN /PAINT 1 /A2.0 C BEDROOM 2 1 2' -11" x 3' -0" STAIN /PAINT 1 /A2.0 D BEDROOM 3 1 3-11" x 2-11" STAIN /PAINT 1/A2.0 E BEDROOM 4 2 2' -10" x 3' -10" STAIN /PAINT 1/A2.0 F LAUNDRY 1 4-11" x 2' -4" STAIN /PAINT 1/A2.0 G KITCHEN 1 2' -11" x 2-10" STAIN /PAINT 2/A2.0 H LIVING 3 2' -11" x 3' -11" STAIN /PAINT 1 /A2.0 I LIVING 3 2' -11" x 3-11" STAIN /PAINT 1/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEUJ SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTR JOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) U. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR 51-EATHING LID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW HEAD (E) GWB CONTINUOUS SEALANT, TYP. BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FN WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT NSULATION BACKER ROD 4 SEALANT 3/4" 3/4" WD. SILL - STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MANTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T- 1115IDING AS R EQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING t PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY CAREFULLY CUT BACK (E) T -111 SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANT CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -111 SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL 5IPE5 AND PAINT TO MATCH (E) TRIM. COLOR TO 5E FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE WINDOW HEAD WINDOW JAMB rtai (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM IUD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -ill SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEUJ SIDING AS REQ'D TO MANTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING 4 II II WINDOW SILL /4" (E) GWB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" UV. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTNUOUS SEALANT, TYP. SELF - ADHERING MEMBRANE (E) GWB T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION p i.1-o3ti f, FEB 07 2012 rr ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT TENTE, :STATE OF F-INC Ok 0810.03.2032 9/20/11 0 0 ce J z 0 z W 1-- z H z 0 U z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 z 0 Lct z_ F- DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.032032 DOOR TYPES FLUSH SCW HALF —LITE W/ 2 PANELS W/ SAFETY GLAZING 5 SECONDARY SLIDING GLASS DOOR W/ SAFETY GLAZING G EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING A 3-0" x 6' -8" STAIN /STAIN HW -1/626 DK -4 (CAMELOT) LOCK -1 1/A2.1 2 BEDROOM 4 B 5-11" x 6' -9" STAIN /STAIN 2/A2.1 3 SITTING ROOM A 3' -0" x 6' -7" STAIN /STAIN HW -1/626 DK -2 LOCK -1 1/A2.1 4 LIVING (DOUBLE LEAF) A 5' -10" x 6' -6" STAIN /STAIN HW- 11643E HW- 1/643E DK -2 EXT. DK -3 INT (NEPTUNE) LOCK -1 LOCK -1 1/A2.1 5 LIVING D 3-0" x 6' -8" 1/A2.1 6 SITTING ROOM D 3' -0" x 6' -7" 1/A2.1 7 LIVING (DOUBLE LEAF) C 5' -10" x 6' -6" 1/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF— ADHERING MEMBRANE AGANST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE UJ/ NEW SIDING 4 PANT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF— AD1- 4ERING MEMBRANE. PAINT COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEHND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MN. (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING DOOR HEAD (E) EXTERIOR SHEATHING fCONTINUOUS — SEALANT, TYP. EXISTING FRAMING CONTINUOUS SEALANT BEHND X BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER— STRIPPNG HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR JAMB DOOR 5HOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR SILL SOLID WOOD TRIM 514IM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 "= 1' -0„ (E) T -111 SIDING PRE — PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF— ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED N THE FIELD SELF ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE I5 VISIBLE BELOW FLASHING EDGE 2X TAPERED CAP TRIM AWAY (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY. TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) BLDG. PAPER BACKER ROD AND SEALANT PLYWOOD DOOR HEAD PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF— ADHERING MEMBRANE. PANT COLOR TO BE SELECTED IN NE FIELD CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PAINT TO MATCH (E) TRIM SELF — ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR kl 1/2" MIN BETWEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE REMOVE (E) AND REPLACE SIDNG COURSES AS REQ'D. CAREFULLY LIFT (E) WALL UNDERLATENT AND INSTALL TOP EDGE OF SELF — ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB (E) PRIMARY SLIDING DOOR ASSEMBLY (E) T -111 SIDING (E) EXTERIOR SHEATHING CAREFULLY LIFT (E) WALL UNDERLAYMENT. LAP GRADE D WALL UNDERLAYMENT UNDER (E) WALL UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME (E) PRIMARY SLIDING GLASS DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. SEALANT (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING (E) FLOOR/ DECK FRAMING 1 DOOR SILL T -111 SIDING - DOOR DETAIL SET 3" = 1 I - 011 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION b().w4r9 FEB 07 2012 -� • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 -COT E`rPET STATE a € ,MINC (lF 0810.03.2032 9/20/11 0 0 J z 0 I— z w 1-- z F- 0 0 0 z AIP NUMBER MPROVEMENTS 0 w w w C/) 0 z U Q J Q Z w O w ce 3 -53 -0058 -044 z O 0 z_ cn J_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2032 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYR AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF- ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH: PAINT NTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET N MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3" = 1' - 0" BLENDING AIR UNIT DETAIL 3" = 1 i - 0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL DISPLACE (E) INSULATION TO FACILITATE INSTALLATION OF MECHANICAL UNIT, DUCTS AND ACCESS HATCH CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL INSULATION STOP AT PERIMETER OF ACCESS HATCH OPENNG, 4 SIDES - 2x IUD BLOCKING EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION NSULATION DAM (E) WALL FRAMING INSULATION DAM DETAIL 3 " =1' -0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE 1 ii. V.V.V.V.W.W.V.W.WAVAVAW EXISTING VENT COVER EXISTING ROOF (STRUCTURE CROSS SECTION NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION b" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 3 " =1' -0" (E) 2X10 0 16" O.C. (E) GWB (E) ATTIC DUCT CHASE ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16", INSTALL 2X4 STUDS a 16" O.C. J -METAL EDGE AND CAULK JOINT REVIEWED FOR CODE COMPLIANCE APPROVFO FEB 15 2012 City of Tukwila BUILDING DIVISION EXIST. WALL CONSTR DUCT SOFFIT DETAIL DEMOLISH (E) GWB NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/8" cite- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILNG. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDNATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY 1 1/2" = 1' - 0" (2) SIMPSON A -34 a EACH SIDE PANEL TO SECURE VENT BAFFLE TO (E) WALL FRAMING OPEN TOP EXIST. GABLE VENT NEW 4" GALV. HARDWARE CLOTH }" CDX PLYWOOD AT (3) SIDES I" OWENS CORNING nen INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: L AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. GABLE END VENT BAFFLE DETAIL 3 " =1' -0" D (JO3H FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 v S I LRI:.D u IrRTEM PE: jHINC ON 0810.03.2032 9/20/11 F- ce 0 a_ Q w 0 0 C~7 F- w Z Z Q w Z Z < F- = z U i-- 0 ce 0 < C9 _I Z w 0 w MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2032 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, rm. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDNG AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING I -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA END OF SILL (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 1 FOLD THROUGH RO. AS SHOUNI. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING Ii" MIN BUTTERFLY CORNER FLASHING MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT 51-1OWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. 1 ' ` C O � O O C o O O O MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE <_. NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION (E) SHEATHING REMOVED SCALE: NTS EDGE OF (E) SIDING, 51-1O( DIAGRAMATICALLY. (E) SIDING NOT 5WOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. L HEAD FLASHING PREPARATION J WHERE RE" IRED, TRIM (E) BLDG ' APER AT HEAD TO - ■ PARE FOR INSTA LATION OF HEAD FLA- UG AND WINDOW TR (FOLLOW! ' STEPS). SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING t FOLD AROUND WINDOW OPENING AS 5H011.N. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2� MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDNG BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL 51-1T. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. ALLOW 1/8" LEARANCE BETWEEN FL ING AND BOT. EDGE •' (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 1 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. At HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. MEMBRANE FLASHING AT JAMB SCALE: NTS 10 WOOD TRIM INSTALLATION SCALE: NTS INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARNNG MEMBRANE FLASHING" TYPICALLY REFERED TO AS "FEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1-145 BEEN SET IN PLACE, SHIM'1ED, AND ANCHORED. 4: DETAILS "S AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) R0. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER ATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. 7 WINDOW FLASHING INSTALLATION / SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION Q« -o311 FEB 0 7 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 TT :1r Tr c= IC 0810.03.2032 9/20/11 F- W 0 0_ —J z 0 z w z z 0 0 z AIP NUMBER MPROVEMENTS 0 Cw w ce w 0 z LL 3 -53- 0058 -044 z 0 LCC z J DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2032 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP H VAC HW H WC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SM C SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL A@BB. DESCRIPTION OR XX 0 X /Y / DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE. ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION S-- EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS M2.1 MECHANICAL DETAILS M2.2 KEY TO BLENDING UNIT ZONES GENERAL NOTES SYMBOL ABBR SG -X XXX DN UP VD RA/EA -�� RG -I� SA 1><I SA -0I- - I- RA/EA SD 0-) O 4N- L! E:=> EQUIP ID� OR Cp,, ICI EA MOD NG NG 0 • D'4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. STEEL, : PPO ACKETS, HANGERS, MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1,2 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, 'TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 BV -2 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" CEILING ALGRILLE 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 GO8" WG 4" 4" CEILING DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2032 BV -1 623 2 90 CFM 90 CFM 1 0810.03.2032 BV -2 1005 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. SWITCH HOURS OF OPERATION SET BV -1 AND BV -2 SWITCHES TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION BV -1,2 PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM FEB 07 2012 sic- P '"`MI AND APPROVAL w,r•�r.. ,f.r -w S.M. STEMPER ARCHITECTS A PrOfeeelonal limited Lability Company 4000 DELRIDGE WAY SW SUITE 200 - SEATTLE, WA 98106 (toe) 624 -2777 • FAX (20e) ee4 -297 THE GREENBUSCH GROUP, INC )111000•04114040 AOOIBeCJiL I,,,o,D / vm T 9.111E( ( i' 70-- CCRS.76ovf, s11R20e) - 00044196s1AX 081 0.03.2032 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3 -53 -0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2032 SITTING ROOM 25 BEDROOM 3 SEE TYP ALL CEILING GRILLES TO BLENDING UNIT 1 SEE 25 24' 24' EXIST. AT ACCESS PANEL BEDROOM 2 44TH 1 J BEDROOM RG -1 p 25 44 140 Q SOFFIT INTO 90 CLOSET MAIN FLOOR MECHANICAL PLAN TYP LIVING ROOM KITCHEN I' ' SCALE: 1/4" = 1' -0" 4IFF NORTH / /1 // /I /1 /1 //'`�i 1/ /1 /1 /1 /1 1/ /1 /1 1/ /1 1/ /1 11 /1 1/ /1 1/ SEE /1 // L_ r —� 1/ // /1 1n� /1 /1 /1 1 L ®_- 4 "0 DN (� TO RG -1 OG -1 90 SEE i 4. 1) 4 "0 DN TO RG -1 4 "0 DN TO RG -1 SEE r / 8 "0 DN /1 TO SG -1 / / // L::.d// SWITCH /// // // // ( 1/ 1/ J// 7/ // // / // // // // /1/ 1 / 1r 1 24' x 24' EXIST. ATTIC ACCESS PANEL 7 0 DN J L° 4 "0 DN TO RG -1 DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51- 52- 0403.8.3. FLAG NOTES: BV -1. ¢V -2 AND DUCTWORK ROUTED IN ATTIC. COORDINATE WALL AND MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. E TYP 8" 8 "0 DN TO SG -1 3 r -1 L n II J L ATTIC MECHANICAL PLAN SCALE: 1/4" = 1' -0" NORTH J J SEPARATE D PERMIT APPROVAL REQU FEB 07 2012 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Pro[eee10nal Limited LU.bllty Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 824 - 2973 THE GREENBUSCH GROUP, INC ••••••••• ) lin tor ,r PSO%, srEr IRE 201 SFJV tL N119 (206) 378 -0669 (208) 378 -0841 FAX 0810.03.2032 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS M2.0 0810.03.2032 INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS RETURN AIR DUCT OUTSIDE AIR DUCT 16" MIN HOLD TIGHT TO STRUCTURE BV -1.2 FILTERS ACCESS MOTOR ACCESS USE ENLARGED ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS ATTIC NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL SCALE: NONE b1o3H hP FEB 07 2012 S.M. STEMPER ARCHITECTS A Professional limited U.mttq Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 28108 (208) 024 -2777 • FAX (206) 024 -2973 THE GREENBUSCH GROUP, INC V°FO oIo� s sn 2111 Mi (206) 370 -0669 (206) 376 -0641 FAX 0810.03.2032 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058-044 DATE ISSUED 9/16/11 BID PACKAGE M -27 100% CD PROJECT ENGINEER DO TUKWILA WASHINGTON PROJECT MANAGER DO DRAWN JA, DT lava M2.1 0810.03.2032 MAIN FLOOR FEB 07 2012 iippROvAL 11 n • S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • sFArrug. WA 98106 (200 624-2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP, INC )000.••401141 leousnac_ _ Aurp 14120 6 WECHVICIL 1310116ENNO 11100 VIEST1N STREET SUITE 201 $661LE. WA 06110 (206) 376-0660 (206) 376-0641 FAX 0810.03.2032 KING COUNTY INTERNATIONAL AIRPORT AIP NUMBER 3-53-0058-044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M-27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT KEY TO BLENDING UNIT ZONES M2.2 0810.03.2032 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOUTION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL. DEVICES SHALL BE LJMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. Q HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810,03.2032 CONTROL EQUIPMENT 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR DESCRIPTION RESIDENCE AIC, 125 AMP with MAIN 15 16 15 CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 SPACE X A ■ BV -2 BLENDING UNIT VENTILATOR 120 SPACE 2 3 SPACE X 15/1 1,2 EXISTING LOAD 4 I 5 BLENDING UNIT X 20!1 * A 20/1 X EXISTING LOAD 6 7 BLENDING UNIT 2011** 30/2 EXISTING LOAD 8 9 EXISTING LOAD 15/1 A 10 11 EXISTING LOAD 20/1 fl 20/1 EXISTING LOAD 12 13 EXISTING LOAD 20/1 A 20/1 EXISTING LOAD 14 15 EXISTING LOAD 15/1 20/2 EXISTING LOAD 16 17 EXISTING LOAD 20/1 A 18 19 EXISTING LOAD 20/1 8 20/1 EXISTING LOAD 20 21 EXISTING LOAD 20/1 A 20/1 EXISTING LOAD 22 23 EXISTING LOAD 20/1 B 20/1 EXISTING LOAD 24 25 EXISTING LOAD 30/2 A 20/2 EXISTING LOAD 26 27 B 28 29 31 33 35 37 39 41 EXISTING LOAD EXISTING LOAD 20/1 20/1 A A A A B B 8 20/1 20/1 EXISTING LOAD EXISTING LOAD 30 32 34 36 38 40 42 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS 0 RAINTIGHT NEMA_3R ENCLOSURE FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH • ❑ REMARKS: " PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. ELECTRICAL LEGEND Sl''hOL DESCRIPTION SYMBOL DESCRIPTION LIGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2'C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. } INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION ❑, NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. THERMOSTAT CEILING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT UNE VOLTAGE ARE ALARM SMOKE /CARBON MONOXIDE DETECTOR 2'4 F " EtIST. AT1 O ACCESS FANEL MECI- IANICAL. / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS , PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VEN1ILATOR 120 1 X X X 1,2 BV -2 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH E..4Tk BEaR001 -- EETROOM MAIN FLOOR PLAN 1/4" = 1' hoc° C KITG�IEN T 411r NORTH p ().-0314 FEB 07 2012 S.M,STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 821 -2777 • FAX (206) 824 -29 73 0810.03.2032 0 I_ J z 0 i- < z w z KING COUNTY AIP NUMBER MPROVEMENTS 0 w w w O J D ce 5 -53- 0058 -043 DATE 918/11 ISSUED M-27 100° PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2032