HomeMy WebLinkAboutPermit D12-035 - TRAN RESIDENCE - UPGRADESTRAN RESIDENCE
12222 47 AV S
D12-035
City oifikukwila
1
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 0179001155
Address: 12222 47 AV S TUKW
Suite No:
Project Name: TRAN RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D12-035
Issue Date: 03/20/2012
Permit Expires On: 09/16/2012
Owner:
Name: TRAN QUYNH CHI
Address: 12222 47TH AVE S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $20,988.00 Fees Collected: $811.18
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -035 Printed: 03 -20 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
• •
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non- Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: ' 1 -2
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Date: 3/20/ %Z
Print Name: I e :Cam ✓ tarp -y
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D12-035 Printed: 03 -20 -2012
this requirement.
•
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
doc: IBC -7/10
D12-035 Printed: 03 -20 -2012
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Pe o.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 12222 47th Avenue S.
Tenant Name:
Quynh Chi Tran
King Co Assessor's Tax No.: 0179001155
Suite Number: Floor:
New Tenant: ❑ Yes ®..No
Property Owners Name: Quynh Chi Tran
Mailing Address: 4604 S. 122nd St.
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
1
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
206) 624 -2777
Day Telephone: (
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
HMpplications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Appltcation.doc
Revised: 1 -2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ' $ ION -- 206 - 431 -3670
Valuation of Project (contractor's bid price): $ 20,988 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: 1Applications'Forms- Applicati ons On Line/009 Applications .1-2009 - Permit Appl ication. dot
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
970
2 °d Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: 1Applications'Forms- Applicati ons On Line/009 Applications .1-2009 - Permit Appl ication. dot
Revised: 1 -2009
bh
Page 2 of 6
• •
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORI E �.' I NT:
Signature:
Print Name:
Date: ((/ Fzeito 1
e N vtsoN Day Telephone: 14(0 (p Z'4 " Z� T
Mailing Address:
City
State
Zip
Date Application Accepted:
Date Application Expires: Staff Initials:
H :Wpplieations\Forms- Appltcanons On Lme\2009 Applications \I-2009 - Permit Appltcation.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPINOERMIT ,INFORMATION — 206 - 43570
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Cod
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Indicate type of plumbing fixtures and/or gas pip `•,t outlets being ins 'ed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
. ture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
y'
t Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
�
r,,,
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
`
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater an f• sr vent
/
':,•ustrial waste treatment
in` <,, eptor, including trap
and''$cnt, except for kitchen
type • R-. se interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair .;- alteration of
water/ping and/or water
trea•yent equipment
Repair ,,.1teration of
drainage i~ivent piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
F'.ckflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protec i, e device
other than atmosp` -•& c -type
vacuum breakers ov-'NI,
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflo
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H \Applications `•Forms - Applications On- Line.2009 Applicalionsl1 -2009 Permit Application.doc
Revised: 1 -2009
bb
Page 5 of 6
Ci f of Tukwila. •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206-431-3665
Web site: http : //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -00879
Initials: WER
Payment Date: 03/01/2012
User ID: 1655 Total Payment: 17,659.72
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED
SET TRANSACTIONS:
Set Member Amount
D12 -025
D12 -026
D12 -027
D12 -028
D12 -029
D12 -030
D12 -031
D12 -032
D12 -033
D12 -034
D12 -035
D12 -036
D12 -037
D12 -038
D12 -039
TOTAL:
993.76
1,313.36
1,313.36
1,042.93
993.76
1,239.61
1,411.70
993.76
1,387.12
1,165.85
811.18
905.73
1,460.87
1,190.44
1,436.29
993.76
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 17,659.72
TOTAL: 17, 659.72
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 10,661.95
000.345.830 6,930.27
640.237.114 67.50
TOTAL: 17, 659.72
INSPECTION RECORD
Retain a copy with permit ! Z -
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Type o�fzInspe do •
Address: j t.
I � Z 1- 4 } -Ave.. .
I Z i 1-.2.. in --Special
1
Date Called:
Date Called:
Instructions:
'
Date Wanted:. �t .m 1
1l- V� -,Z_ Or
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
dY"----
% -0:1i. LC.\,4(,
I--
f- , 4 A-L_ __
c: M. , I
(, T(c,Cf:
p
1
InsgEctor:
Dater - 1
REINSPECTION FEE R�QUIRED. Prior to next inspection, fee must be
paid at 6300 Southcent r Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTIO NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
D(2 -03S
Project �. I `�
�xlA . j s k
Address:
4)7 JAL.
Type f,Inspecti n:
:vAL. --D..) (0 11C
f ti
Special Instructions:
Date Called:
Date Wanted:. j.
f� ( I' f P.m.
Requester:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
(\o V ft-r✓
Date:
Inspector: l `_; I
J ` I ,
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Insulation Northnest LLC
NORTHWEST DI
Emulation lationn Ce>ritif ca to /
Batts and Blankets
When installed in accordance with the manufacturers
recommendations, Knauf batts and blankets will provide
the full R- value.
R- Value'
Minimum Thickness
To Obtain An insulation
resistance (R- Value) of:
Installed insulation should
not be less than:
R -38HD
10.25"
R -38
12.00"
R -30HD
8.25"
R -30
10.00"
R -26
9.00"
R -22
6.50"
R -21HD
5.50"
R -19
6.25 ""
R -15HD
3.50"
R -13
3.50"
R -11
3.50"
R -8
2.50"
^R -18 in a 5.5" cavity. Con orms to ASTM C665 and
Federal Specification HH- I -521F.
I:
lower Door Test Forum
Thermal Performance (Attic Application)
The stated thermal resistance (R- value) is provided by installing in accordance with the manufactuers instructions, the required number of
bags per 1,000 sq.ft of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at
least the minimum thickness will result in lower insulation R- value.
R- Value'
Bags /1,000 sq. ft. 1
Maximum Coverage
Minimum Weight
Minimum Thickness
To Obtain an insulation
resistance (R- Value) of:
The number of
bags /1,000 SF of net
area should not be
Contents of this bag should not
cover more than
The weight/SF of installed
insulation should not be
less tharr
Installed insulation should
not be Tess than:
R -60
31.7
31.5 SF
_952 LBS
R -38
19.75"
R -49
25.8
38.7 SF
.774 LBS
Floors (over an unheated crawl space)
16.75"
R-44
22.1
45.3 SF
.663 LBS
14.75"
R -38
19.0
52.7 SF
.569 LBS
13.00"
R -30
14.4
69.7 SF
.431 LBS
10.25"
R -26
12.4
80.9 SF
.371 LBS
9.00"
R -22
10.4
95.8 SF
.313 LBS
7.75"
R -19
8.9
111.8 SF
.268 LBS
6.75"
R -13
6.1
164.3 SF
.183 LBS
4.75"
R -11
5.1
197.6 SF
.152 LBS
1
4.00"
Bag Weight - Nominal 301bs., Minimum 7.9 lbs. This product comforms to the performance requirements of ASTM C 764, Type I, and
cancelled Federal Specification HH- I- 10 :08, Type I, Class B. R- Values are determined in accordance with C 687 and C 518. '•'R" means
resistance to heat flow. The higher the R- value, the greater the insulation power. To get the marked R- value, it is eseential that the
insulation be Instaled properly. If you do it yourself, get instructions and follow them carefully.
To achieve labeied R- value. this product must be applied with a pneumatic blowing machine and a
corrugated hose with a minimum .25" internal corrugation, a minimum length of 150 ft and a diameter
of at least 3 ". Coils in the hose should not be less than 36" in diameter. Acceptable material feed
rate is 5-35 lbs. /minute. Recommended feed rate is 15-25 Ibs./minute_
Builders Insulation Statement
Batts and/or blankets have been installed ir. conformance with the above recommendations to
provide a thermal resistance of...
2009 WSEC Residential Energy Compliance
Certificate - Building Air Leakage
Building & Test Condition Comments
Cate:
Time:
indoor Temperature:
Outdoor 'errn perature:
Floor Area (ft;)
Affidavit:
.13uildineAir Leaka '"e Tar"et :.SLA Less than 0.00030
Test #1
Depress ... Press .�
Pretest Baseline Pressure:_ (Pa)
Bldg Press. (Pe)
Flow Ring
R -Value
Flow (cfm)
Standard
Attic Area
R•
.
R-49
Sloped Ceilings
R•
R -38
Walls
R-
I
R -21
Floors (over an unheated crawl space)
R-
I
R -30
Completed as of: �/ /d //Z
/eve so
Site Address: /4.R.Z2- 'V7,
#.4..//4.0
Home Builder
Signature:
Home Builder
Address:
Insulation
Contractor: Insulation Northwest LLC
P.O. Box 732069
Puyallup, WA 98373
Phone: (253) 846 -0121
Fax: (253) 846 -8096
Affidavit:
.13uildineAir Leaka '"e Tar"et :.SLA Less than 0.00030
Test #1
Depress ... Press .�
Pretest Baseline Pressure:_ (Pa)
Bldg Press. (Pe)
Flow Ring
Fa (Pa)ss.
Flow (cfm)
Post -Test Pressure:
Fan Model /SN:
(Pa)
Results:
SLA (Specific Leakage Area):
Test #2
Depress Press .�
Pretest Basel:ne Pressure._ (Pe)
Bldg Press. (Pa)
Flow Ring
Fan Press. Flow (cfm)
(Pa)
Post -Test Pressure: . (Pa)
Fan ModellSN:
Results:
SLA (Specific Leakage Area):
I certify that this Specific Leakage Area is accurate and determined us;rg Brower Door Test Standard 502.4.5 Building Air Leakage Testing.
Name
Technician. Signature
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
October 1, 2012
Timothy J. Fenlason
S.M. Stemper Architects
4000 Delridge Wy SW, Ste 200
Seattle, WA 98106
RE: Request for Extensions
KCIA RANR!P Permits D12 -025 through D12 -039
Dear Mr. Fenlason,
This letter is in response to your written request for an extension to Permit Numbers D12 -025
through D12-039. The Building Official has reviewed your letter and considered your request to
extend the above referenced permits. The City of Tukwila Building Division will be extending
your permits an additional 60days from the date of expiration, November 15, 2012.
If you should have any questions, please contact our office at (206) 431 -3670.
Jen fifer Mar•
• e it echn
File: Permit No. D12 -025 through D12 -039
W.\Permit Center \Extension Letters\Permits\2012 \D12 -025 Permit Extcnsion.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
10 -01 -2012
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -035
TRAN RESIDENCE
12222 47 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumping Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 11/15/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will he notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 11/15/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Ov■c4A6a
er Marshall
Technician
File: Permit File No. D12 -035
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 -431 -3665
S.M. STEMPER ARCHITECTS
A Professional Limited Liability Company
13 September 2012
Bill Rambo, Permit Technician
City ofTukwila, Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, WA 98188
RE: Bid Package M -27 Permits
Dear Mr. Ram bo,
This letter serves as written request to extend the permits listed below, which are part of King County
International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RAN RIP).
Permit Address Permit Number Permit Address Permit Number
12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033
11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034
5003 S. 113th St. D12 — 027 12222 47th Ave S. D12 — 035
12228 49th Ave. S. D12 -- 028 12215 48th Ave S. D12 — 036
5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12 — 03 7
11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038
11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039
12203 47th Ave S. D12 —032
Perm its for these properties were requested by our office as the homeowner's representative since this is
a public project and is bid in accordance with grant requirements.
A contract has been awarded and construction is in progress, but will not be complete by the end date of
the original permits. Extension on all properties should be made for an additional 60 days.
If you need further clarification or have questions, please contact me at 206 -721 -0061 or
tfenlason@jonespayne.com.
I , cklo .€1 .mot �o �=
ctfrolzatz
Timothy J. Fen Jason
Project Manager
The Jones Payne Group, Inc.
AkL;EivEiY
MY OF TUKWILA
85P 13 20121
PERMIT CENTER
�uP o4ullL
4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 • 206/ 624 -2777 • FAX 206/ 624-2973
442\1c11-,
08 -01 -2012
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -035
TRAN RESIDENCE
12222 47 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 09/16/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
File: Permit File No. D12 -035
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665
!IH-4141141 CAVIO
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -035
PROJECT NAME: TRAN RESIDENCE
SITE ADDRESS: 12222 47 AV S
X Original Plan Submittal
Response to Correction Letter #
DATE: 02 -07 -12
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
B ling lJivision �C
N_Ns AM-
Public Works
AY/1
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
[4,
Incomplete
Planning Division ICI
Permit Coordinator
DUE DATE: 02 -09 -12
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
nNo further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
n
Approved with Conditions
DUE DATE: 03-08 -12
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
•
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.00
03/06/2012
3
Landmark American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
03/20/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27
3- 53- 0058 -044
FILE COPY
Penult No. 1
Plan review approval is abject to snore and ofniss
Approval of construction dot:wants does not authorize
ihe violation of any adopted code or or11tlatice. Receipt
of approved Fill Copy and conditions ilsacknowledged:
Datt
City Of lbkwIta
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR
iMachanical
Electrical
Plumbing
Sa Gas POIV
City of Tukwila
BUILDING DIVISION,
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
b12- O35
FEB 07 2012
VICINITY MAP (NTS)
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
ZONING: 5F1200
DCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
Y 8 NON SPRINKLERED
0119001155
I-ECAL DESCRIPTION:
ALLENTOWN ADD 5 i/2 OF LOT 1 ALL OF LOT 8 AND N 1/2 OF LOT 9
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
Cityo
BUILDIN
kwila
(VISION
DRAWING INDEX
Told
141.0
1420
A2.1
A22
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WIDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MI.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS MD DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY NTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E -ma i I: 51-a ryn.Pa rkereking county.,gov
ARCHITECT:
S.M. Stamper Architects PL.LCC.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Phi 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlaeon,
E -mail: jerryesmstemper.com
melodyesmetemper.com
timesmetemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA %MOOS
Ph: 206. an. 0819
Fax: 206.839.0824
Contact: Mohamed Ait Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph 206. 318. 0569
Fax: 206.318.0641
Contact: Dylan Turner
E -mail: Dylantegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 5. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIAL&
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. s639
Fax: 206.162. 4180
Contact: Tim Ogden
E -mail: tin ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washinnggton St. '200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mall: JCornwellejoneapayne.com
STRUCTURAL ENGINEER
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E -mall: rormepsm- engineers.com
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE NFiLTRATION OF AIRCRAFT NOISE AND PROVIDE
-DE CONTR4CT C INCLUDES ALL INFORMATION IN THE DRAWINGS AND
MECHANICAL VENTILATION. L B NOT LI D
APPLICABLE
YES NO
1 SELECTIVE REPLACEMENT OF EXISTING WNDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WNDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
1 INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. NSTALLATION OF SECONDARY SLIDING STORM DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
a INSTALLATION OF PET DOORS.
X
9A NSTALLATION OF MECHANICAL VENTILATION EQUIFIIENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
9.B INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
12. NSTALLATION OF FIREPLACE FRESH AIR VENT.
X
13. INSTALLATION OF CHIMNEY CAP.
X
14. NSTALLATION OF SMOKE DETECTORS.
X
15. REGULATED MATERIALS ABATEMENT.
X
16. ATTIC VENT BAFFLES.
X
11. NSTALLATION OF ATTIC NSULAtION.
X
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REDSTE -RE'.
;OTT DARE•
DATE O v r DliINGIOry
9/20/11
0810.03.2033
MPROVEMENTS
z
0
z_
CO
AIP NUMBER
3- 53- 0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
L B & SW
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2033
,m
MAIN FLOOR PLAN
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SWEET FOR WINDOW REPLACEMENT.
a ALL WORK AREAS SHALL SE BROOM- CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVNG AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDNATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO NTER:ERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILNG FNISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH NE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET EIO FOR LOCATIONS AND PETALS OF NTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER S:00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN -FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW MD DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WNDOW COVERINGS MUST BE PROVIDED.
1/4" = 1'
4
A. WEST ELEVATION
36' -0"
Li!
1
1
1
1
\
1- 1
L
LI
I!L 1
LI
HI
r1
j4
1
1
1
/
/1
ATTIC PLAN
1/4" = 1'
B. NORTH ELEVATION
PLAN KEYNOTES
DI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
DEMOLISH EXISTING OR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
O DOOR SCHEDULE. DO
3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 022 FOR DETAIL. COORDINATE WIN
MECHANICAL DOCUMENTS.
0 INSTALL SECONDARY SLIDING GLASS DOOR REF. A2.1 FOR DOOR SCHEDULE.
0 INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) N ATTIC, REF. 3/422 FOR DETAIL.
O NStALL NEW THERMOSTAT: COORDINATE WIN MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. EAST ELEVATION
LEGEND
0
,A
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR NTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO PETAL
EXTERIOR ELEVATION P1-1070 VIEW
REVIEWED FOR
CODE COMPLIANCE
APPROVED M
FEB 15 2012
of BUILD NG DIVISION
D. SOUTH ELEVATION
p«.- O3S
GABLE END VENT BAFFLE FEB 07 2012
RIDGE VENT BAFFLE
FEATHER TEXTURED CEILING OVER AT A
i MIN. OF 24" FROM EDGE OF PATCHING.
=.1 MATCH (E) TEXTURE AND PANT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
i AND WHOLE HOUSE VENT NSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
ATTIC INSULATION
SD NSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
SOFFIT FOR MECHANICAL DUCTNG
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELEIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
ST.` [ +
-CI id LC
Ps�TEMPE�
.STATE: 03= 1-0INGION
0810.03.2033
9/20/11
F--
O
0
J
z
0
Lll
z
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
w
w
w
0)
O
z
LL
U
H-
z
0
3 -53- 0058 -044
z
0
1-
z
(I)
F--
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
FLOOR
PLANS
NOTES
A1.0
0810.03.2033
WINDOW TYPES
SLIDER
2.
SINGLE I-LING
OR
DOUBLE HUNG
WINDOW SCHEDULE
DETAIL
SET
WINDOW
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
REMARKS
A
OFFICE
1
3' -11 "x 3' -11"
STAIN /PAINT
1/A2.0
B
KITCHEN
1
2' -10" x 1' -10"
STAIN /PAINT
2/A2.0
C
BEDROOM 1
2
2' -10" x 3' -11"
STAIN /PAINT
2/A2.0
D
BEDROOM 1
1
4' -11" x 2' -11"
STAIN /PAINT
2/A2.0
E
BEDROOM 2
1
4' -10" x 2' -10"
STAIN /PAINT
2/A2.0
F
BEDROOM 2
2
2' -10" x 3' -10"
STAIN /PAINT
1/A2.0
G
LIVING
1
4' -10" x 3' -11"
STAIN /PAINT
1/A2.0
TYPICAL WINDOW SCHEDULE NOTES
t NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
(E) IUD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 FAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
(E) GUS
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
CONTNUOUS
SEALANT, TYP.
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMNED
BACKER ROD 4 SEALANT
ACOUSTICAL WNDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO W.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGANST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PANT FASTENER DADS
AND ANY CRACKS WINCH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR 5HEATHING
LID WOOD TRIM
WD. JAMB LINING
SEALANT
51-11M AS NECESSARY
FILL GAP W/ BATT
INSULATION
WINDOW HEAD
(E) GWB
CONTINUOUS
SEALANT, TYP.
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE HELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSNG 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WP SIDING
WINDOW JAMB
SOLID WOOD TRIM
WD JAM LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/4"
3/4" WD. SILL - STAIN TO
MATCH (E)
SOLID WOOD TRIM
CONTNUOUS
SEALANT, TYP.
WINDOW SILL
(E) GIUB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) T -111 SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT t0 MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) T -III SIDING
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
510NG FROM INSTALLATION OF
FLASHING
(E) T -III SIDING
WINDOW HEAD
1-
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
CONTNUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 SACKER ROD
SHIM AS NECESSARY
FILL GAP W/ 'BATT
INSULATION
GUS
r,_� -- CONTINUOUS
SEALANT, TYP.
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAIL FLANGE
WINDOW JAMB
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
NSULATION
BACKER ROD 4
SEALANT
3/4" IUD. SILL - STAIN
10 MATCH (E)
SOLID WOOD TRIM
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) T -111 SIDING
FOR INSTALLATION OF WNDOW
ASSEMBLY AND TRIM. REPLACE W/
NEW SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E)
SIDING
(E) EXTERIOR SHEATHING
WINDOW SILL
SELF- ADHERING
MEMBRANE
(E) GWB
T -111 SIDING - WINDOW DETAIL SET
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
t).-o3 s
FEB 07 2012
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
SCOTT PiR Rti PlEH
STATE ( _ ING T Oi\
0810.03.2033
9/20/11
O
0
J
z
0
>-
z
LU
z
F-
z
O
0
z
AIP NUMBER
MPROVEMENTS
0
w
2
w
w
0
z
U
ac
3-53- 0058 -044
z
0
1-
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2033
DOOR TYPES
A
FLUSH SCW
W! WAGON WHEEL
W/ SAFETY GLAZING
W/ OBSERVATION PORT
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH INT. /EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK SET
DETAIL SET
1
LIVING
A
3' -0" x 6' -8"
PAINT /PAINT
HW -1/626
DK -2
LOCK -1
1/A2.1
2
BEDROOM 4
B
5' -11" x 6' -9"
PAINT /PAINT
2/A2.1
3
LIVING
C
3' -0" x 6' -8"
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT
ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT
CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS
SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
(E) IUD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADI- IERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PANT
TO MATCH (E) SIDING
PRE - PRIMED, GALV SHEET METAL CAP
FLASHING UNDER SELF- ADHERING
MEMBRANE. PAINT COLOR TO BE
SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
SELF - ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RO. FRAMING.
LIFT (E) WALL LNDERLAYMENt AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
DOOR HEAD
(E) EXTERIOR SHEATHING
CONTINUOUS
"7- SEALANT, TYP.
EXISTING FRAMING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTNUOUS WEATHER- STRIPPING
I- LARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
" MIN.
DOOR JAMB
DOOR SILL
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
NSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3" = 1' - 0"
(E) t -111 SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. PANT COLOR TO BE SELECTED
IN THE FIELD
SELF ADHERING MEMBRANE. TURN
DOWN OVER FRONT EDGE OF TRIM.
ENSURE NO MEMBRANE IS VISIBLE
BELOW FLASHING EDGE
2X TAPERED CAP
TRIM AWAY (E) SIDING TO
FACILITATE INSTALLATION OF
FLASHING AND DOOR HEAD
ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR
FRAME. PANT ALL EXPOSED
EDGES TO MATCH (E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
NSTRUCTIONS
(E) BLDG. PAPER
BACKER ROD AND SEALANT
PLYWOOD
11111111-14 _.
■i —
DOOR HEAD
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. PAINT COLOR TO BE
SELECTED N THE HELD
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
SELF- ADHERING MEMBRANE
SECONDARY SLIDING STORM D
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
WD. TRIM BEYOND
SECONDARY SLIDING STORM
DOOR ASSEMBLY. INSTALL PER
MFG'R INSTRUCTIONS.
SEALANT
(E) FLOOR/ DECK FRAMING
i" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
REMOVE (E) AND REPLACE SIDING
COURSES AS REQ'D. CAREFULLY LIFT
(E) WALL UNDERLAYMENT AND INSTALL
TOP EDGE OF SELF- ADHERING
MEMBRANE AGANST SHEATHING. LAP
(E) WALL UNDERLAYMENT OVER TOP
OF SELF- ADHERNG MEMBRANE. TYP
AT HEAD AND JAMB
(E) PRIMARY SLIDING DOOR
ASSEMBLY
(E) T -III SIDING
(E) EXTERIOR SHEATHING
CAREFULLY LIFT (E) WALL
UNDERLAYMENT. LAP WALL
UNDERLAYMENT UNDER (E) WALL
UNDERLAYMENT 2" AND CONTINUE
OVER SLIDING GLASS DOOR FRAME
(E) PRIMARY SLIDING
GLASS DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
DOOR SILL
T -111 SIDING - DOOR DETAIL SET
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
1)1)---035
FEB 0 7 2012
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELEIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGSTERED
CIEC
T»TT Pi E4',t'E
:- INGTON
0810.03.2033
9/20/11
Et
0
0
ce
J
z
0
Q
z
cc
w
z_
1--
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
w
w
ce
w
0
z
U
a
J
Q
H
Z
W
D
W
3 -53- 0058 -044
z
0
z_
Q
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2033
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERNG
MEMBRANE AGAINST SHEATI -ING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF - ADHERING
MEMBRANE. TYP. AT +MEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE - PRIMED, GALV. SWEET METAL
FLASHING W/ F.F. END GAPS UNDER
SELF- ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR TO
BE SELECTED N THE HELD
SELF - ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
PAINT VENTILATION FIXTURE,
COLOR TO BE SELECTED N
THE FIELD
2X2 CONTNUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPNG
COMPOUND. SET N MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' —Odd
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
INSULATION DAM DETAIL
3 "= 1' -0"
INSULATION
NSULATION DAM
(E) WALL FRAMING
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2 "X SPACER
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW I" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
ROOF VENT BAFFLE DETAIL
1 1/2 = 1' — 0"
Dig -�3s
FEB 07 2012
1
S.MSTEMPER
ARCHITECTS
4 Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
STEED
COTT
STATE 0=
0810.03.2033
9/20/11
O
a
J � Z
Z W OO
O WC7
Z
Z (I)
Z Q
LL �j
H
0
U Q
() J
Z Q
w
0
ct
w
MPROVEMENTS
AIP NUMBER
3 -53 -0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
MISC.
DETAILS
A2.2
0810.03.2033
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND I4EAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL ExTEND 1 in
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROO��U�GH RO. AS
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
I" MIN
MEMBRANE FLASHING AT SILL
BUTTERF Y CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 51-10U 1N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE: -->"
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL
1 '
O
O
O
p
O
o
p
,
r-
O O O
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4�i WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE MP
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO FREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
(2)
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMAT !CALL Y.
(E) SIDING NOT
SWOON FOR
CLARITY.
5
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW I /8" LEARANCE
BETWEEN ING AND
BOT. EDGE '' (E)
SIDING.
9 HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
/3 MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT I4EAD
FLASHING t FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
R.O. AT HEAD
AND JAM65.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHIN G
OVER WNDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADI4EARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 51 OUJN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD N GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
FEB 07 2012
1
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
CiSTEHED
SCOTT
S;ATE 0:- HINGTGP
0810.03.2033
9/20/11
i-
ce
0
0
ce
J
z
0
z
ce
w
1--
z
F-
0
U
AIP NUMBER
MPROVEMENTS
3 -53 -0058 -044
z
O
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2033
r-
Z
‘
___:
INSTALL HEAD
FLANGE FLASHIN G
OVER WNDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADI4EARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 15 2012
City of Tukwila
BUILDING DIVISION
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 51 OUJN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD N GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
FEB 07 2012
1
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
CiSTEHED
SCOTT
S;ATE 0:- HINGTGP
0810.03.2033
9/20/11
i-
ce
0
0
ce
J
z
0
z
ce
w
1--
z
F-
0
U
AIP NUMBER
MPROVEMENTS
3 -53 -0058 -044
z
O
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2033
ABBREVIATIONS
LEGEND
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STA11C PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
XX
OR X,
0
X /Y /
DESCRIPTION
DETAIL OR SEC11ON CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT UNE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT UNE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
DRAWING INDEX
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS AND DETAILS
GENERAL NOTES
1.
THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT 6 0, AD ► ONAL STEEL, SUPPORT BRACK HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
fr(tck u 1 ca-1 30011-
7ec, Ye�
SYMBOL
SG -X
XXX
.61512.E.
1■I
1>a
0-,
0 0-
VD
RA /EA
RG
SA
SA
RA /EA
SD
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
OR
THERMOSTAT
EQUIP IDS EQUIPMENT LOCATION
NG
•
D
O
t1
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
337
<.08 "WG
7 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STA11C
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
90
337
<.08 "WG
7 "0
EXTERIOR
1,2
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2033
1107
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SEC11ON 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE
(NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
THERMOSTAT HOURS OF OPERATION
SET THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
(1.---0 35
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 4a
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2.
QF = 45 / (1 X 1/2) = 90 CFM
FEB 07 2012
S.M. STEMPER
ARCHITECTS
A Profeeduuel Matted Udall Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 96108
(xoe) 624 -2777 • FAX (206) 624 -2073
THE GREENBUSCH GROUP, INC
/o U!NCM.. ACM t IECEING1L END•EERIN0
1600 WEST NCINGION SMELT SLOE 201 SENILE, M 1161111
(20e) 376-0609 (200) 376 -0641 FAX
0810.03.2033
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3- 53- 0058 -044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.2033
(E)SG
KITCHEN
(E)EG
(E)SG
CEZI
BATH
(E)EG
OFF ICE
SG
ESGm
2
LIVING (E)RG
ROOM
►.t
(E)SG
BEDROOM
C
BEDROOM
2
(E)SG
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
(E) RETURN
MOD, INTERLOCK
TO FURNACE
POC
ATTIC
FCU
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
FAN COIL UNIT DETAIL
(E) HWR
(E) SUPPLY
(E) HWS
SCALE: NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
r-
L
L
ATTIC MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
DUCT PER PLAN
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1 /A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
SCALE: NONE
J
NORTH
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FCU SYSTEM.
FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
2. FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER WAC 51 -52- 0403.8.3.
SEE ELECTRICAL DOCUMENTS FOR FCU WIRING MODIFICATION.
3. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN
SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL
CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH
ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FCU IS WITHIN 4
FEET OF FCU RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FCU
RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING
THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF
OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO
ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE
REUSED.
Q I.)-U3s
FEB 07 2012
S.M. STEMPER
ARCHITECTS
A Pro[ewdo.el limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(206) 624 -2777 • FAX (206) 624 -2273
THE GREENBUSCH GROUP, INC
ACOUSIGIL. O 11O0D 10E1 HMlC111 DIalEIIi
1000 VID k SI SII6ET DE SDI SENILE IM 0616N 14
rill (206) 376 -0641 FAX
0810.03.2033
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2033
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WIN ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WRING SPECIFICATIONS FOR SWITCH.
KITCHEN
I-,
OFFICE
L H/ NG,
="
EE fOCM
E€ 7, FROCM
rh
T
MAIN FLOOR PLAN
1/4" = 1'
NORTH
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
UGHIING OR POWER PANEL
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
02 AWG, 1/2'C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
INDICATES ISOLATED GROUND.
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
a
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
SMOKE DETECTOR
ELECTRICAL METER
11MER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
O
THERMOSTAT
CEILING MOUNTED FIRE ALARM - VISUAL STROBE UGHT
UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
1" IECI-IANICAL ! ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIP11ON
VOLTS
PH
-
15
16
15
16
N/A
15
16
N/A
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
LL
C
L
tL-O3S
FEB 07 2012
SEPARAI p
■
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
■USINS�ea. INO
SOIrni MS Min OM NI
MIMS I
MIN ■w A MS
0810.03.2033
cc
0
a
Q
J
Z
0
H
Q
ec
z
w
z
z
0
U
0
Z
AIP NUMBER
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
5-53- 0058 -043
z
0
z
J
DATE
9/8/11
ISSUED M -27
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES