HomeMy WebLinkAboutPermit D12-035 - TRAN RESIDENCE - UPGRADESTRAN RESIDENCE 12222 47 AV S D12-035 City oifikukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179001155 Address: 12222 47 AV S TUKW Suite No: Project Name: TRAN RESIDENCE DEVELOPMENT PERMIT Permit Number: D12-035 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: TRAN QUYNH CHI Address: 12222 47TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $20,988.00 Fees Collected: $811.18 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -035 Printed: 03 -20 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: ' 1 -2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 3/20/ %Z Print Name: I e :Cam ✓ tarp -y This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12-035 Printed: 03 -20 -2012 this requirement. • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IBC -7/10 D12-035 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Pe o. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12222 47th Avenue S. Tenant Name: Quynh Chi Tran King Co Assessor's Tax No.: 0179001155 Suite Number: Floor: New Tenant: ❑ Yes ®..No Property Owners Name: Quynh Chi Tran Mailing Address: 4604 S. 122nd St. Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 1 Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State 206) 624 -2777 Day Telephone: ( Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: HMpplications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Appltcation.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFO ' $ ION -- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 20,988 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: 1Applications'Forms- Applicati ons On Line/009 Applications .1-2009 - Permit Appl ication. dot Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 970 2 °d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: 1Applications'Forms- Applicati ons On Line/009 Applications .1-2009 - Permit Appl ication. dot Revised: 1 -2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI E �.' I NT: Signature: Print Name: Date: ((/ Fzeito 1 e N vtsoN Day Telephone: 14(0 (p Z'4 " Z� T Mailing Address: City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H :Wpplieations\Forms- Appltcanons On Lme\2009 Applications \I-2009 - Permit Appltcation.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPINOERMIT ,INFORMATION — 206 - 43570 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Cod Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas pip `•,t outlets being ins 'ed and the quantity below: Fixture Type: Qty Fixture Type: Qty . ture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet y' t Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) � r,,, Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals ` Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater an f• sr vent / ':,•ustrial waste treatment in` <,, eptor, including trap and''$cnt, except for kitchen type • R-. se interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair .;- alteration of water/ping and/or water trea•yent equipment Repair ,,.1teration of drainage i~ivent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 F'.ckflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protec i, e device other than atmosp` -•& c -type vacuum breakers ov-'NI, inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflo protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H \Applications `•Forms - Applications On- Line.2009 Applicalionsl1 -2009 Permit Application.doc Revised: 1 -2009 bb Page 5 of 6 Ci f of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206-431-3665 Web site: http : //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION RECORD Retain a copy with permit ! Z - INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Type o�fzInspe do • Address: j t. I � Z 1- 4 } -Ave.. . I Z i 1-.2.. in --Special 1 Date Called: Date Called: Instructions: ' Date Wanted:. �t .m 1 1l- V� -,Z_ Or Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: dY"---- % -0:1i. LC.\,4(, I-- f- , 4 A-L_ __ c: M. , I (, T(c,Cf: p 1 InsgEctor: Dater - 1 REINSPECTION FEE R�QUIRED. Prior to next inspection, fee must be paid at 6300 Southcent r Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D(2 -03S Project �. I `� �xlA . j s k Address: 4)7 JAL. Type f,Inspecti n: :vAL. --D..) (0 11C f ti Special Instructions: Date Called: Date Wanted:. j. f� ( I' f P.m. Requester: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (\o V ft-r✓ Date: Inspector: l `_; I J ` I , n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Insulation Northnest LLC NORTHWEST DI Emulation lationn Ce>ritif ca to / Batts and Blankets When installed in accordance with the manufacturers recommendations, Knauf batts and blankets will provide the full R- value. R- Value' Minimum Thickness To Obtain An insulation resistance (R- Value) of: Installed insulation should not be less than: R -38HD 10.25" R -38 12.00" R -30HD 8.25" R -30 10.00" R -26 9.00" R -22 6.50" R -21HD 5.50" R -19 6.25 "" R -15HD 3.50" R -13 3.50" R -11 3.50" R -8 2.50" ^R -18 in a 5.5" cavity. Con orms to ASTM C665 and Federal Specification HH- I -521F. I: lower Door Test Forum Thermal Performance (Attic Application) The stated thermal resistance (R- value) is provided by installing in accordance with the manufactuers instructions, the required number of bags per 1,000 sq.ft of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness will result in lower insulation R- value. R- Value' Bags /1,000 sq. ft. 1 Maximum Coverage Minimum Weight Minimum Thickness To Obtain an insulation resistance (R- Value) of: The number of bags /1,000 SF of net area should not be Contents of this bag should not cover more than The weight/SF of installed insulation should not be less tharr Installed insulation should not be Tess than: R -60 31.7 31.5 SF _952 LBS R -38 19.75" R -49 25.8 38.7 SF .774 LBS Floors (over an unheated crawl space) 16.75" R-44 22.1 45.3 SF .663 LBS 14.75" R -38 19.0 52.7 SF .569 LBS 13.00" R -30 14.4 69.7 SF .431 LBS 10.25" R -26 12.4 80.9 SF .371 LBS 9.00" R -22 10.4 95.8 SF .313 LBS 7.75" R -19 8.9 111.8 SF .268 LBS 6.75" R -13 6.1 164.3 SF .183 LBS 4.75" R -11 5.1 197.6 SF .152 LBS 1 4.00" Bag Weight - Nominal 301bs., Minimum 7.9 lbs. This product comforms to the performance requirements of ASTM C 764, Type I, and cancelled Federal Specification HH- I- 10 :08, Type I, Class B. R- Values are determined in accordance with C 687 and C 518. '•'R" means resistance to heat flow. The higher the R- value, the greater the insulation power. To get the marked R- value, it is eseential that the insulation be Instaled properly. If you do it yourself, get instructions and follow them carefully. To achieve labeied R- value. this product must be applied with a pneumatic blowing machine and a corrugated hose with a minimum .25" internal corrugation, a minimum length of 150 ft and a diameter of at least 3 ". Coils in the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 lbs. /minute. Recommended feed rate is 15-25 Ibs./minute_ Builders Insulation Statement Batts and/or blankets have been installed ir. conformance with the above recommendations to provide a thermal resistance of... 2009 WSEC Residential Energy Compliance Certificate - Building Air Leakage Building & Test Condition Comments Cate: Time: indoor Temperature: Outdoor 'errn perature: Floor Area (ft;) Affidavit: .13uildineAir Leaka '"e Tar"et :.SLA Less than 0.00030 Test #1 Depress ... Press .� Pretest Baseline Pressure:_ (Pa) Bldg Press. (Pe) Flow Ring R -Value Flow (cfm) Standard Attic Area R• . R-49 Sloped Ceilings R• R -38 Walls R- I R -21 Floors (over an unheated crawl space) R- I R -30 Completed as of: �/ /d //Z /eve so Site Address: /4.R.Z2- 'V7, #.4..//4.0 Home Builder Signature: Home Builder Address: Insulation Contractor: Insulation Northwest LLC P.O. Box 732069 Puyallup, WA 98373 Phone: (253) 846 -0121 Fax: (253) 846 -8096 Affidavit: .13uildineAir Leaka '"e Tar"et :.SLA Less than 0.00030 Test #1 Depress ... Press .� Pretest Baseline Pressure:_ (Pa) Bldg Press. (Pe) Flow Ring Fa (Pa)ss. Flow (cfm) Post -Test Pressure: Fan Model /SN: (Pa) Results: SLA (Specific Leakage Area): Test #2 Depress Press .� Pretest Basel:ne Pressure._ (Pe) Bldg Press. (Pa) Flow Ring Fan Press. Flow (cfm) (Pa) Post -Test Pressure: . (Pa) Fan ModellSN: Results: SLA (Specific Leakage Area): I certify that this Specific Leakage Area is accurate and determined us;rg Brower Door Test Standard 502.4.5 Building Air Leakage Testing. Name Technician. Signature City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANR!P Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers D12 -025 through D12-039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Jen fifer Mar• • e it echn File: Permit No. D12 -025 through D12 -039 W.\Permit Center \Extension Letters\Permits\2012 \D12 -025 Permit Extcnsion.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 10 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -035 TRAN RESIDENCE 12222 47 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumping Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will he notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Ov■c4A6a er Marshall Technician File: Permit File No. D12 -035 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206 -431 -3665 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 13 September 2012 Bill Rambo, Permit Technician City ofTukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Ram bo, This letter serves as written request to extend the permits listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RAN RIP). Permit Address Permit Number Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034 5003 S. 113th St. D12 — 027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 -- 028 12215 48th Ave S. D12 — 036 5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12 — 03 7 11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039 12203 47th Ave S. D12 —032 Perm its for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original permits. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 -721 -0061 or tfenlason@jonespayne.com. I , cklo .€1 .mot �o �= ctfrolzatz Timothy J. Fen Jason Project Manager The Jones Payne Group, Inc. AkL;EivEiY MY OF TUKWILA 85P 13 20121 PERMIT CENTER �uP o4ullL 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 • 206/ 624 -2777 • FAX 206/ 624-2973 442\1c11-, 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -035 TRAN RESIDENCE 12222 47 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, File: Permit File No. D12 -035 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 !IH-4141141 CAVIO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -035 PROJECT NAME: TRAN RESIDENCE SITE ADDRESS: 12222 47 AV S X Original Plan Submittal Response to Correction Letter # DATE: 02 -07 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: B ling lJivision �C N_Ns AM- Public Works AY/1 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: [4, Incomplete Planning Division ICI Permit Coordinator DUE DATE: 02 -09 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: n Approved with Conditions DUE DATE: 03-08 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27 3- 53- 0058 -044 FILE COPY Penult No. 1 Plan review approval is abject to snore and ofniss Approval of construction dot:wants does not authorize ihe violation of any adopted code or or11tlatice. Receipt of approved Fill Copy and conditions ilsacknowledged: Datt City Of lbkwIta BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR iMachanical Electrical Plumbing Sa Gas POIV City of Tukwila BUILDING DIVISION, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. b12- O35 FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code ZONING: 5F1200 DCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) Y 8 NON SPRINKLERED 0119001155 I-ECAL DESCRIPTION: ALLENTOWN ADD 5 i/2 OF LOT 1 ALL OF LOT 8 AND N 1/2 OF LOT 9 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 Cityo BUILDIN kwila (VISION DRAWING INDEX Told 141.0 1420 A2.1 A22 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WIDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS MD DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY NTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E -ma i I: 51-a ryn.Pa rkereking county.,gov ARCHITECT: S.M. Stamper Architects PL.LCC. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Phi 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlaeon, E -mail: jerryesmstemper.com melodyesmetemper.com timesmetemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA %MOOS Ph: 206. an. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E -mail: Dylantegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIAL& PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. s639 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: tin ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washinnggton St. '200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mall: JCornwellejoneapayne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mall: rormepsm- engineers.com SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE NFiLTRATION OF AIRCRAFT NOISE AND PROVIDE -DE CONTR4CT C INCLUDES ALL INFORMATION IN THE DRAWINGS AND MECHANICAL VENTILATION. L B NOT LI D APPLICABLE YES NO 1 SELECTIVE REPLACEMENT OF EXISTING WNDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WNDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 1 INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. NSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X a INSTALLATION OF PET DOORS. X 9A NSTALLATION OF MECHANICAL VENTILATION EQUIFIIENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 9.B INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. NSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. X 14. NSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. NSTALLATION OF ATTIC NSULAtION. X • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REDSTE -RE'. ;OTT DARE• DATE O v r DliINGIOry 9/20/11 0810.03.2033 MPROVEMENTS z 0 z_ CO AIP NUMBER 3- 53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2033 ,m MAIN FLOOR PLAN GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SWEET FOR WINDOW REPLACEMENT. a ALL WORK AREAS SHALL SE BROOM- CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVNG AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDNATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO NTER:ERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILNG FNISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH NE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EIO FOR LOCATIONS AND PETALS OF NTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER S:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN -FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW MD DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WNDOW COVERINGS MUST BE PROVIDED. 1/4" = 1' 4 A. WEST ELEVATION 36' -0" Li! 1 1 1 1 \ 1- 1 L LI I!L 1 LI HI r1 j4 1 1 1 / /1 ATTIC PLAN 1/4" = 1' B. NORTH ELEVATION PLAN KEYNOTES DI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING OR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. O DOOR SCHEDULE. DO 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 022 FOR DETAIL. COORDINATE WIN MECHANICAL DOCUMENTS. 0 INSTALL SECONDARY SLIDING GLASS DOOR REF. A2.1 FOR DOOR SCHEDULE. 0 INSTALL VENT BAFFLES) AT EXISTING ROOF VENTS) N ATTIC, REF. 3/422 FOR DETAIL. O NStALL NEW THERMOSTAT: COORDINATE WIN MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. EAST ELEVATION LEGEND 0 ,A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR NTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO PETAL EXTERIOR ELEVATION P1-1070 VIEW REVIEWED FOR CODE COMPLIANCE APPROVED M FEB 15 2012 of BUILD NG DIVISION D. SOUTH ELEVATION p«.- O3S GABLE END VENT BAFFLE FEB 07 2012 RIDGE VENT BAFFLE FEATHER TEXTURED CEILING OVER AT A i MIN. OF 24" FROM EDGE OF PATCHING. =.1 MATCH (E) TEXTURE AND PANT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL i AND WHOLE HOUSE VENT NSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION SD NSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTNG • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ST.` [ + -CI id LC Ps�TEMPE� .STATE: 03= 1-0INGION 0810.03.2033 9/20/11 F-- O 0 J z 0 Lll z z 0 U z AIP NUMBER MPROVEMENTS 0 w w w 0) O z LL U H- z 0 3 -53- 0058 -044 z 0 1- z (I) F-- DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2033 WINDOW TYPES SLIDER 2. SINGLE I-LING OR DOUBLE HUNG WINDOW SCHEDULE DETAIL SET WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS A OFFICE 1 3' -11 "x 3' -11" STAIN /PAINT 1/A2.0 B KITCHEN 1 2' -10" x 1' -10" STAIN /PAINT 2/A2.0 C BEDROOM 1 2 2' -10" x 3' -11" STAIN /PAINT 2/A2.0 D BEDROOM 1 1 4' -11" x 2' -11" STAIN /PAINT 2/A2.0 E BEDROOM 2 1 4' -10" x 2' -10" STAIN /PAINT 2/A2.0 F BEDROOM 2 2 2' -10" x 3' -10" STAIN /PAINT 1/A2.0 G LIVING 1 4' -10" x 3' -11" STAIN /PAINT 1/A2.0 TYPICAL WINDOW SCHEDULE NOTES t NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. (E) IUD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 FAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GUS (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTNUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO W. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGANST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER DADS AND ANY CRACKS WINCH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR 5HEATHING LID WOOD TRIM WD. JAMB LINING SEALANT 51-11M AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW HEAD (E) GWB CONTINUOUS SEALANT, TYP. BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE HELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSNG 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WP SIDING WINDOW JAMB SOLID WOOD TRIM WD JAM LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTNUOUS SEALANT, TYP. WINDOW SILL (E) GIUB WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T -111 SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT t0 MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) T -III SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN 510NG FROM INSTALLATION OF FLASHING (E) T -III SIDING WINDOW HEAD 1- (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTNUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 SACKER ROD SHIM AS NECESSARY FILL GAP W/ 'BATT INSULATION GUS r,_� -- CONTINUOUS SEALANT, TYP. (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE WINDOW JAMB SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT NSULATION BACKER ROD 4 SEALANT 3/4" IUD. SILL - STAIN 10 MATCH (E) SOLID WOOD TRIM TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -111 SIDING FOR INSTALLATION OF WNDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING WINDOW SILL SELF- ADHERING MEMBRANE (E) GWB T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION t).-o3 s FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 SCOTT PiR Rti PlEH STATE ( _ ING T Oi\ 0810.03.2033 9/20/11 O 0 J z 0 >- z LU z F- z O 0 z AIP NUMBER MPROVEMENTS 0 w 2 w w 0 z U ac 3-53- 0058 -044 z 0 1- z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2033 DOOR TYPES A FLUSH SCW W! WAGON WHEEL W/ SAFETY GLAZING W/ OBSERVATION PORT SECONDARY SLIDING GLASS DOOR W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING A 3' -0" x 6' -8" PAINT /PAINT HW -1/626 DK -2 LOCK -1 1/A2.1 2 BEDROOM 4 B 5' -11" x 6' -9" PAINT /PAINT 2/A2.1 3 LIVING C 3' -0" x 6' -8" 1/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. (E) IUD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADI- IERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PANT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF- ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF - ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL LNDERLAYMENt AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING DOOR HEAD (E) EXTERIOR SHEATHING CONTINUOUS "7- SEALANT, TYP. EXISTING FRAMING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTNUOUS WEATHER- STRIPPING I- LARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE " MIN. DOOR JAMB DOOR SILL SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT NSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3" = 1' - 0" (E) t -111 SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. PANT COLOR TO BE SELECTED IN THE FIELD SELF ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE IS VISIBLE BELOW FLASHING EDGE 2X TAPERED CAP TRIM AWAY (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PANT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R NSTRUCTIONS (E) BLDG. PAPER BACKER ROD AND SEALANT PLYWOOD 11111111-14 _. ■i — DOOR HEAD PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED N THE HELD CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PAINT TO MATCH (E) TRIM SELF- ADHERING MEMBRANE SECONDARY SLIDING STORM D ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. SEALANT (E) FLOOR/ DECK FRAMING i" MIN. BETWEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE REMOVE (E) AND REPLACE SIDING COURSES AS REQ'D. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGANST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERNG MEMBRANE. TYP AT HEAD AND JAMB (E) PRIMARY SLIDING DOOR ASSEMBLY (E) T -III SIDING (E) EXTERIOR SHEATHING CAREFULLY LIFT (E) WALL UNDERLAYMENT. LAP WALL UNDERLAYMENT UNDER (E) WALL UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME (E) PRIMARY SLIDING GLASS DOOR (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING DOOR SILL T -111 SIDING - DOOR DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION 1)1)---035 FEB 0 7 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGSTERED CIEC T»TT Pi E4',t'E :- INGTON 0810.03.2033 9/20/11 Et 0 0 ce J z 0 Q z cc w z_ 1-- z 0 U z AIP NUMBER MPROVEMENTS 0 w w ce w 0 z U a J Q H Z W D W 3 -53- 0058 -044 z 0 z_ Q DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2033 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERNG MEMBRANE AGAINST SHEATI -ING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. AT +MEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV. SWEET METAL FLASHING W/ F.F. END GAPS UNDER SELF- ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED N THE HELD SELF - ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED N THE FIELD 2X2 CONTNUOUS PRESSURE TREATED BLOCKING, 4 SIDES EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPNG COMPOUND. SET N MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. AIR INTAKE DETAIL AT EXTERIOR 3 " =1' —Odd EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 "= 1' -0" INSULATION NSULATION DAM (E) WALL FRAMING REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION EXISTING VENT COVER EXISTING ROOF STRUCTURE EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1 1/2 = 1' — 0" Dig -�3s FEB 07 2012 1 S.MSTEMPER ARCHITECTS 4 Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 STEED COTT STATE 0= 0810.03.2033 9/20/11 O a J � Z Z W OO O WC7 Z Z (I) Z Q LL �j H 0 U Q () J Z Q w 0 ct w MPROVEMENTS AIP NUMBER 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2033 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND I4EAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING I -1/2" OVER (E) BLDG. PAPER AT SILL ExTEND 1 in BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROO��U�GH RO. AS ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I" MIN MEMBRANE FLASHING AT SILL BUTTERF Y CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51-10U 1N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: -->" EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL 1 ' O O O p O o p , r- O O O MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4�i WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE MP OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO FREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. (2) CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMAT !CALL Y. (E) SIDING NOT SWOON FOR CLARITY. 5 MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I /8" LEARANCE BETWEEN ING AND BOT. EDGE '' (E) SIDING. 9 HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER /3 MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT I4EAD FLASHING t FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND R.O. AT HEAD AND JAM65. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL HEAD FLANGE FLASHIN G OVER WNDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADI4EARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51 OUJN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD N GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS FEB 07 2012 1 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 CiSTEHED SCOTT S;ATE 0:- HINGTGP 0810.03.2033 9/20/11 i- ce 0 0 ce J z 0 z ce w 1-- z F- 0 U AIP NUMBER MPROVEMENTS 3 -53 -0058 -044 z O z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2033 r- Z ‘ ___: INSTALL HEAD FLANGE FLASHIN G OVER WNDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADI4EARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 15 2012 City of Tukwila BUILDING DIVISION NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51 OUJN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD N GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS FEB 07 2012 1 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 CiSTEHED SCOTT S;ATE 0:- HINGTGP 0810.03.2033 9/20/11 i- ce 0 0 ce J z 0 z ce w 1-- z F- 0 U AIP NUMBER MPROVEMENTS 3 -53 -0058 -044 z O z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2033 ABBREVIATIONS LEGEND ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STA11C PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR XX OR X, 0 X /Y / DESCRIPTION DETAIL OR SEC11ON CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT UNE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT UNE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE DRAWING INDEX M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT 6 0, AD ► ONAL STEEL, SUPPORT BRACK HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. fr(tck u 1 ca-1 30011- 7ec, Ye� SYMBOL SG -X XXX .61512.E. 1■I 1>a 0-, 0 0- VD RA /EA RG SA SA RA /EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH OR THERMOSTAT EQUIP IDS EQUIPMENT LOCATION NG • D O t1 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 <.08 "WG 7 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STA11C PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 90 337 <.08 "WG 7 "0 EXTERIOR 1,2 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2033 1107 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SEC11ON 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. THERMOSTAT HOURS OF OPERATION SET THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS. (1.---0 35 MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) 4a &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2. QF = 45 / (1 X 1/2) = 90 CFM FEB 07 2012 S.M. STEMPER ARCHITECTS A Profeeduuel Matted Udall Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 96108 (xoe) 624 -2777 • FAX (206) 624 -2073 THE GREENBUSCH GROUP, INC /o U!NCM.. ACM t IECEING1L END•EERIN0 1600 WEST NCINGION SMELT SLOE 201 SENILE, M 1161111 (20e) 376-0609 (200) 376 -0641 FAX 0810.03.2033 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2033 (E)SG KITCHEN (E)EG (E)SG CEZI BATH (E)EG OFF ICE SG ESGm 2 LIVING (E)RG ROOM ►.t (E)SG BEDROOM C BEDROOM 2 (E)SG MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" (E) RETURN MOD, INTERLOCK TO FURNACE POC ATTIC FCU VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING FAN COIL UNIT DETAIL (E) HWR (E) SUPPLY (E) HWS SCALE: NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE r- L L ATTIC MECHANICAL PLAN SCALE: 1 /4" = 1' -0" DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE J NORTH DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FCU SYSTEM. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 2. FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -52- 0403.8.3. SEE ELECTRICAL DOCUMENTS FOR FCU WIRING MODIFICATION. 3. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FCU IS WITHIN 4 FEET OF FCU RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FCU RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. Q I.)-U3s FEB 07 2012 S.M. STEMPER ARCHITECTS A Pro[ewdo.el limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624 -2273 THE GREENBUSCH GROUP, INC ACOUSIGIL. O 11O0D 10E1 HMlC111 DIalEIIi 1000 VID k SI SII6ET DE SDI SENILE IM 0616N 14 rill (206) 376 -0641 FAX 0810.03.2033 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3 -53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2033 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WIN ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WRING SPECIFICATIONS FOR SWITCH. KITCHEN I-, OFFICE L H/ NG, =" EE fOCM E€ 7, FROCM rh T MAIN FLOOR PLAN 1/4" = 1' NORTH ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION UGHIING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. 02 AWG, 1/2'C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION a NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR ELECTRICAL METER 11MER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. O THERMOSTAT CEILING MOUNTED FIRE ALARM - VISUAL STROBE UGHT UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR 1" IECI-IANICAL ! ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIP11ON VOLTS PH - 15 16 15 16 N/A 15 16 N/A MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH LL C L tL-O3S FEB 07 2012 SEPARAI p ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■USINS�ea. INO SOIrni MS Min OM NI MIMS I MIN ■w A MS 0810.03.2033 cc 0 a Q J Z 0 H Q ec z w z z 0 U 0 Z AIP NUMBER RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS 5-53- 0058 -043 z 0 z J DATE 9/8/11 ISSUED M -27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES