HomeMy WebLinkAboutPermit D12-037 - FERTAKIS RESIDENCE - UPGRADESFERTAKIS RESIDENCE
11822 42 AV S
D12-037
City oftukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3347400225
Address: 11822 42 AV S TUKW
Suite No:
Project Name: FERTAKIS RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D12 -037
Issue Date: 03/20/2012
Permit Expires On: 09/16/2012
Owner:
Name: FERTAKIS JON E +MARY E
Address: 11822 42ND AVE S , SEATTLE WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION .AND ABATEMENT).
Value of Construction: $44,378.00 Fees Collected: $1,460.87
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7110
D12 -037 Printed: 03 -20 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
• •
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non- Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name:
Zee 6"
ye9 o" 7
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date:
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D12 -037 Printed: 03 -20 -2012
this requirement.
•
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -037 Printed: 03 -20 -2012
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukivi/a.wa. us
Building Perim ? o. b (d- -6 3 7
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 11822 42nd Avenue S.
Tenant Name: Jon E. and Mary E. Fertakis
Property Owners Name: Jon E. and Mary E. Fertakis
Mailing Address: 11822 42nd Avenue S.
King Co Assessor's Tax No.: 3347400225
Suite Number:
New Tenant:
Floor:
❑ Yes al ..No
98168
Zip
Tukwila
WA
City
State
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
H:Wppluations\Forms- Applications On Ltne\2009 Applications \I-2009 - Penuit Applicanon.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFO
ION — 206 -431 -3670
Valuation of Project (contractor's bid price): $ 44,378 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm l None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach fist of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
HP,Applications'•Forms- Applications On Line,2009 Applications'•.I -2009 - Permit Application.doc
Revised: t -2009
bh
Page 2 of 6
Existing •
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
810
2nd Floor
690
3'a Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm l None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach fist of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
HP,Applications'•Forms- Applications On Line,2009 Applications'•.I -2009 - Permit Application.doc
Revised: t -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR T, <<, IZED AGENT:
Signature: I ► EI
Print Name:
Day Telephone:
Date: l Z
Mailing Address:
City
State
Zip
Date Application Accepted: Date Application Expires:
Staff Initials:
H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPINOTRMIT INFORMATION — 206 -4 670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Intl Building Cod
Occupancy (per lnt'l Building Code):
Utility Purveyor: Water:
ewer:
Indicate type of plumbing fixtures and/or gas pipin outlets being in , lled and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
'' ixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
."
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
''
r'
t
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
"
Wash fountain
Receptor, indirect waste
Sinks
Urinals �'
`.ter Closet
`+.
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/: vent
/
Ind ''. ,, 'al waste treatment
intercotor, including trap
and ven \except for kitchen
type rea\ interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or ;�` eration of
water pi y` g and/or water
treatm =; t equipment
Repair or a i;a . tion of
drainage or v piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets /outsets greater
than 5
Ba : " ow protective
d ;'ice other than
ospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protecti :, device
other than atmosphe , -type
vacuum breakers over
inch (51 mm) diameter `1:
°a
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:,Applications 'Forms- Applications On- Linei2009 Applicationsll -2009 Permit Application :doe
Revised: 1 -2009
bh
Page 5 of 6
Ci f of Tukwila.
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: ht4i : //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -00879
Initials: WER
Payment Date: 03/01/2012
User ID: 1655 Total Payment: 17,659.72
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED
SET TRANSACTIONS:
Set Member Amount
D12 -025
D12 -026
D12 -027
D12 -028
D12 -029
D12 -030
D12 -031
D12 -032
D12 -033
D12 -034
D12 -035
D12 -036
D12 -037
D12 -038
D12 -039
TOTAL:
993.76
1,313.36
1,313.36
1,042.93
993.76
1,239.61
1,411.70
993.76
1,387.12
1,165.85
811.18
905.73
1,460.87
1,190.44
1,436.29
993.76
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 17,659.72
TOTAL: 17, 659.72
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 10,661.95
000.345.830 6,930.27
640.237.114 67.50
TOTAL: 17, 659.72
INSPECTION RECORD
Retain a copy with permit
INSPECTION'NO. PERMIT NO.
CITY OF TUKWILA BUILDING QIVISION
6300 5outhcenter Blvd., #100, Tukwila. WA 98188 2" (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pro e"T ti,&
A.---017
TYPe . 10 A- ...
0
Address:
)[t��``L.�..., -1
7:61
Date Called:
Speciallnstructions:
Date Wanted: t
f
,{
p.m:
Requester:
Piton�°
Approved per applicable codes. Corrections required prior to approval
COMMENTS:
Insp ctor:
Dace:.
•
n REINSPECTION FEE REQUIRE . for to next inspection fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedute'reinspection.
City of Tukwila
21
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
October 1, 2012
Timothy J. Fenlason
S.M. Stemper Architects
4000 Delridge Wy SW, Ste 200
Seattle, WA 98106
RE: Request for Extensions
KCIA RANRIP Permits D12 -025 through D12 -039
Dear Mr. Fenlason,
This letter is in response to your written request for an extension to Permit Numbers D12 -025
through D12 -039. The Building Official has reviewed your letter and considered your request to
extend the above referenced permits. The City of Tukwila Building Division will be extending
your permits an additional 60days from the date of expiration, November 15, 2012.
If you should have any questions, please contact our office at (206) 431 -3670.
File: Permit No. DI2 -025 through D12 -039
W \Permit Center\Extension Letters\Pemiits\2012\D12 -025 Permit Extension.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
S.M. STEMPER ARCHITECTS
A P r o ( e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y
13 September 2012
Bill Rambo, Permit Technician
City of Tukwila, Department ofCommunity Development
6300 Southcenter Boulevard, Suite #100
Tukwila, WA 98188
RE: Bid Package M -27 Permits
Dear Mr. Rambo,
This letter serves as written request to extend the permits listed below, which are part of King County
International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RANRIP).
Permit Address Permit Number Permit Address Permit Number
12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033
11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034
5003 S. l 13th St. D12 —027 12222 47th Ave S. D12 — 035
12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036
5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12-037
11602 40th Ave S. D12 — 030 12507 50th PIS. D12 — 038
11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039
12203 47th Ave S. D12 — 032
Permits for these properties were requested by our office as the homeowner's representative since this is
a public project and is bid in accordance with grant requirements.
A contract has been awarded and construction is in progress, but will not be complete by the end date of
the original permits. Extension on all properties should be made for an additional 60 days.
If you need further clarification or have questions, please contact me at 206 - 721 -0061 or
tfenlason@onespayne.com.
(,,A, . /4. :c16o
4/4bevtizei.
c/Z 00 /Z
Timothy J. Fenlason
Project Manager
The Jones Payne Group, Inc.
CITY OF TUKWItA
SP 13 20121
PERMIT CENTER
t\cP 01W112
4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106 • 206/ 624 -2777 . FAX 206/ 624 -2973
tjG 417\1c1/1-,
10 -01 -2012
City of'Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -037
FERTAKIS RESIDENCE
11822 42 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumping Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 11/15/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 11/15/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
V4-111(
r Marshall
Technician
File: Permit File No. D 12 -037
6300 SouthcenterBoulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431 -3665
08 -01 -2012
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D12 -037
FERTAKIS RESIDENCE
11822 42 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 09/16/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
File: Permit File No. D12 -037
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665
411) Gtt 5. ti
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -037
PROJECT NAME: FERTAKIS RESIDENCE
SITE ADDRESS: 11822 42 AV S
X Original Plan Submittal
Response to Correction Letter #
DATE: 02 -07 -12
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: —l3.
ding
Public Work s
Fire Prevention
Structural
a NIA
IP
Planning Division
Permit Coordinator
IL]
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 02 -09-12
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03 -08 -12
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
•
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
$1,000,000.00
03/06/2012
3
Landmark American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03 /10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
03/20/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27
3- 53- 0058 -044
vim` EF F TE PERMIT
R=OC' ED FOR:
fieChanicai
t ectricai
pry6mbing
U Gas POMO
City of Tukwila
BUILDING DIVISION
FILE COPY
Permit No., \')- CA1
P4 rc 4sw approval Is subject to errors and omisskms,
i; t ,ai of construction documents does not authorize
:, ,),a4jon of any adopted code or ordinance. Receipt
o; Lp;praysd Field Copy and conditions is acknowledged:
By
Date: ,
City Of T'llkwita
BUILDING DIVISION
REVISIONS
t:'n chengas shall be made to the scope
c i l 'onrk without prior approval of
;.0 ` <17;la Building Division.
wiz require a new plan submittal
,„„ may in .:ude additional plan review fees.
b12 037
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 17 2012
ity of Tukwila
BUILDING DIVISION
FEB 07 2012
VICINITY MAP (NTS)
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 international Residential Code,
international Fire Code,
International Mechanical Code
3341400225
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV 01
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
v 5 NON SPRINKLEREP
DRAWING INDEX
T0.0
AI.O
A2.0
A2.I
422
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MI.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX
Mao MECHANICAL PLANS AND DETAILS
Ei.O ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206. 2%. 0190
Contact: Sheryl Parker
E- mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stamper Architects PL.L.C.
4000 Pslridge Way 5W, Suite 200
Seattle, WA 98106
Ph 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmstempercom
timesmstemper.com
ACOUSTICAL ENGINEER
554 Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Ait Allaoua
E -mail: mohame:dessaacousticscom
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph 206. 318. 0569
Fax: 206.318.0641
Contact: Dylan Turner
E -mail: Dylantegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E -mail: rim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washinnggton St. 0200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E-mail: JCornwelleJonespayne.com
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E -mail: ronmepsm- engineers.com
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION.
UD NG BUT NOT LIMITED CONTRACT ALL INFORMATION IN THE DRAWINGS AND
APPLICABLE
YES NO
1 SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL- FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFiLL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING STORM DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
y
/�
9.5 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
10. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
V
/�
12. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
13. INSTALLATION OF CHIMNEY CAP.
X
14. INSTALLATION OF SMOKE DETECTORS.
X
15. REGULATED MATERIALS ABATEMENT.
X
16. ATTIC VENT BAFFLES.
X
11. INSTALLATION OF ATTIC NSULATION.
X
■
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
1000 DELRTDDE WAY SW
SUITE 200 • SEATTLE, WA 08106
(206) 624 -2777 • FAX (206) 624 -2973
r;�
-t''EG STERED
•
lill'f`
0810.03.2035
9/20/11
0
J Q
0
z
W
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
0
LLl
W
LLJ
0)
0
z
LL
0
ce
J
z
LLJ
0
3 -53 -0058 -044
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
L B & SW
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2035
p 037
a
BASEMENT
OFF ICE
FAMILY
ROOM
LOWER FLOOR PLAN
1/8" = 1'
SPECIAL NOTES:
NOTE: TI-115 HOUSE HAS SFECFIC PANT COLORS. CONTRACTOR 51-1ALL
AS51 IE 20 CUSTOM PAINT COLORS FOR INTERIOR PAINT MATCHING.
NOTE:
LEAD PANT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
r�
24' -3"
T
111111111111
4-1
24" x 30" EXIST
ATTIC ACCESS
PANEL
k � Gfil
11 f
„LIT. 17117
.. 1 I f 1Arrd
cons
1 �J� f1 11
1 11 1 11
1 .11 f1 11
11 11
�- 1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
L 1
UPPER FLOOR PLAN
1/4" = 1'
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW I5 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT NE END OF EACH WORK DAY.
. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WIN (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQD MD RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING.. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS 14ATCHE5.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILNG FNIS1-ES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.O FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET EID FOR LOCATIONS AND DETAILS OF NTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIh'pM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. ! AFTER 55.00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18 DO NOT INSTALL NEW DOORS OR WINDOWS WERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATNG, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERNGS ARE
NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST SE PROVIDED.
NORTH
A. WEST ELEVATION
B. NORTH ELEVATION
PLAN KEYNOTES
O DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WNDOW ASSEMBLY. REF. WINDOW SCHEDULE.
DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
O DOOR SCHEDULE.
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH
O MECHANICAL DOCUMENTS.
0 REMOVE (E) GARDEN BOX WINDOW, INSTALL ACOUSTICAL GARDEN BOX WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
O DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SI EET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR
WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET.
0 DEMOLISH EXISTING WALL CONSTRUCTION TO ALLOW MECHANICAL DUCT INSTALLATION. INSTALL WALL PATCH TO MATCH ADJACENT EXISTING
CONSTRUCTION. COORDINATE WITH MECHANICAL DOCUMENTS.
O REMOVE AND REINSTALL EXISTING SHELF TO ALLOW MECHANICAL DUCT INSTALLATION.
O INSTALL VENT BAFFLE(S) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/A22 FOR DETAIL.
O INSTALL VENT BAFFLE(S) At EXISTING ROOF VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL.
10 INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
11 INSTALL SECONDARY WINDOW. REF. WINDOW SCHEDULE.
12 NSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWER
13 INSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVNG MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVNG METAL FIREBOXES.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. EAST ELEVATION
ATTIC PLAN
FEB 17 2012
1/8" = 1'
City of Tukwila
BUILDING DIVISION
D. SOUTH ELEVATION
LEGEND
LE
l
L1
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
GABLE END VENT BAFFLE
RIDGE VENT BAFFLE
FEB 072012
FEATHER TEXTURED CEILING OVER AT A
i MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
1 REF. MECH. t ELECT.
a REF. GENERAL NOTE 11
ATTIC INSULATION
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
SOFFIT FOR MECHANICAL DUCTING
gams,
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
AEG %STEEr
4H LC
COTT trt1PEk'
STATE 0 HIN TOf
0810.03.2035
9/20/11
LL.
0
0
J
z
0
Z
W
F--
Z
H
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
cnw
w
w
0
z
U
ce
CA
3-53- 0058 -044
z
O
1—
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
FLOOR
PLANS
NOTES
A1.0
0810.03.2035
WINDOW TYPES
FIXED OVAL
2.
SINGLE HUNG
OR
DOUBLE HUNG
1.
CASEMENT /FIXED /
CASEMENT
t
3.
FIXED
4.
GARDEN WINDOW
SINGLE HUNG SIDES
SLIDER / FIXED / SLIDER
L
CASEMENT / FIXED /
CASEMENT /TRANSOM
ABOVE
CASEMENT
TYPICAL WINDOW SCHEDULE NOTES
NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
FLASHING AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING: FLASHING 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING FLASHING.
REMOVE (E) VINYL SIDING AS REQ'D
FOR INSTALLATION OF WINDOW 4
FLASHING. REPLACE/ RE- NSTALL
SIDING 4 ACCESSORIES TO MATCH (E).
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADI-ERNG
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
UNDETERMINED VNYL SIDING SUBSTRATE
VINYL J CHANNEL TRIM
WINDOW HEAD
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF - ADHERING MEMBRANE
ACOUSTICAL WNDOW ASSEMBLY.
SEALANT 4 BACKER ROD
WINDOW JAMB
OH_
(E) GWB
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
REMOVE AND RENSTALL
(E) CABINETRY AS
NECESSARY
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. CUT BACK (E) BACKER
BOARD AND (E) VINYL SIDING FOR
INSTALLATION OF SELF ADHERING
MEMBRANE. NSTALL SOLID P.T.
BLOCKING TO PROVIDE NAILING
FOR BACKER BOARD. RE- INSTALL
REPLACEMENT BACKER BOARD 4
(E) VINYL SIDING
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) GWB
REMOVE AND REINSTALL
(E) CABINETRY AS
CESSARY
Wp. JAMB LNNG. FNISH TO
MATCH (E)
BACKER ROD SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM. PRIME ALL SIDES ,°
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
VINYL J CHANNEL TRIM
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL AND BACKER BOARD FOR
INSTALLATION OF WNDOW ASSEMBLY 4
TRIM. REPLACE/ RE- INSTALL SIDING TO
MATCH (E)
(E) BACKER BOARD
(E) VINYL SIDING
SEALANT 4 BACKER ROD
1
1
1
SOLID WOOD TRIM
SELF- ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT
CONTINUOUS SEALANT, TYP.
LAP SELF ADHERING
MEMBRANE AT JAMBS
OVER TOP OF SILL
MEMBRANE EXTENSIONS
(E) GWB
WINDOW SILL
VINYL SIDING - WINDOW DETAIL SET
3 " =1' -0"
UNDETERMNED VINYL SIDING SUBSTRATE
(E) BACKER BOARD
(E) VINYL SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
FLASHING AGAINST 51-EATHNG. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING FLASHING.
REMOVE (E) VINYL SIDING AS REQ'D
FOR INSTALLATION OF WINDOW 4
FLASHING. REPLACE/ RE- INSTALL
SIDING 4 ACCESSORIES TO MATCH (E).
VINYL J CHANNEL TRIM
PRE- PRIMED, GALv SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
(E) EXTERIOR SHEATHING
(E) WALL UNDERLAYMENT
(E) WD. PANELING
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT, TYP.
TRIM - MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
UNDETERMINED VINYL SIDING SUBSTRATE
VNYL J CHANNEL TRIM
I 1
WINDOW HEAD
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. CUT BACK (E) BACKER
BOARD AND (E) vNYL SIDING FOR
INSTALLATION OF SELF ADHERING
MEMBRANE. RE- INSTALL
REPLACEMENT BACKER BOARD 4
(E) VINYL SIDING
(E) WD. PANELING
CONTINUOUS SEALANT, TYP.
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PANT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF - ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY.
SEALANT 4 BACKER ROD
WINDOW JAMB
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
TRIM- MATCH (E) TRIM. PRIME ALL SIDES m
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMNED
UNDETERMNED VNYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL AND BACKER BOARD FOR
NSTALLATION OF WINDOW ASSEMBLY 4
TRIM. REPLACE/ RE- INSTALL SIDING TO
MATCH (E)
(E) VNYL SIDING
WINDOW SILL
SELF - ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT 4 ".
CONTNUOUS SEALANT, TYP.
LAP SELF ADHERING
MEMBRANE AT JAMBS
OVER TOP OF SILL
MEMBRANE EXTENSIONS
(E) GWB
VINYL SIDING - WINDOW DETAIL SET
3 " =1' -0"
WINDOW SCHEDULE
J
t L
ROOM
LOCATION
WIND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
CASEMENT / FIXED /
CASEMENT /TRANSOM
ABOVE
CASEMENT
TYPICAL WINDOW SCHEDULE NOTES
NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
FLASHING AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING: FLASHING 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING FLASHING.
REMOVE (E) VINYL SIDING AS REQ'D
FOR INSTALLATION OF WINDOW 4
FLASHING. REPLACE/ RE- NSTALL
SIDING 4 ACCESSORIES TO MATCH (E).
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADI-ERNG
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
UNDETERMINED VNYL SIDING SUBSTRATE
VINYL J CHANNEL TRIM
WINDOW HEAD
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF - ADHERING MEMBRANE
ACOUSTICAL WNDOW ASSEMBLY.
SEALANT 4 BACKER ROD
WINDOW JAMB
OH_
(E) GWB
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
REMOVE AND RENSTALL
(E) CABINETRY AS
NECESSARY
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. CUT BACK (E) BACKER
BOARD AND (E) VINYL SIDING FOR
INSTALLATION OF SELF ADHERING
MEMBRANE. NSTALL SOLID P.T.
BLOCKING TO PROVIDE NAILING
FOR BACKER BOARD. RE- INSTALL
REPLACEMENT BACKER BOARD 4
(E) VINYL SIDING
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) GWB
REMOVE AND REINSTALL
(E) CABINETRY AS
CESSARY
Wp. JAMB LNNG. FNISH TO
MATCH (E)
BACKER ROD SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM. PRIME ALL SIDES ,°
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
VINYL J CHANNEL TRIM
UNDETERMINED VINYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL AND BACKER BOARD FOR
INSTALLATION OF WNDOW ASSEMBLY 4
TRIM. REPLACE/ RE- INSTALL SIDING TO
MATCH (E)
(E) BACKER BOARD
(E) VINYL SIDING
SEALANT 4 BACKER ROD
1
1
1
SOLID WOOD TRIM
SELF- ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT
CONTINUOUS SEALANT, TYP.
LAP SELF ADHERING
MEMBRANE AT JAMBS
OVER TOP OF SILL
MEMBRANE EXTENSIONS
(E) GWB
WINDOW SILL
VINYL SIDING - WINDOW DETAIL SET
3 " =1' -0"
UNDETERMNED VINYL SIDING SUBSTRATE
(E) BACKER BOARD
(E) VINYL SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
FLASHING AGAINST 51-EATHNG. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING FLASHING 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING FLASHING.
REMOVE (E) VINYL SIDING AS REQ'D
FOR INSTALLATION OF WINDOW 4
FLASHING. REPLACE/ RE- INSTALL
SIDING 4 ACCESSORIES TO MATCH (E).
VINYL J CHANNEL TRIM
PRE- PRIMED, GALv SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
(E) EXTERIOR SHEATHING
(E) WALL UNDERLAYMENT
(E) WD. PANELING
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT, TYP.
TRIM - MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY.
(E) BACKER BOARD
UNDETERMINED VINYL SIDING SUBSTRATE
VNYL J CHANNEL TRIM
I 1
WINDOW HEAD
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SEALANT 4 BACKER ROD
CAREFULLY REMOVE (E) VINYL
SIDING. CUT BACK (E) BACKER
BOARD AND (E) vNYL SIDING FOR
INSTALLATION OF SELF ADHERING
MEMBRANE. RE- INSTALL
REPLACEMENT BACKER BOARD 4
(E) VINYL SIDING
(E) WD. PANELING
CONTINUOUS SEALANT, TYP.
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PANT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
SELF - ADHERING MEMBRANE
ACOUSTICAL WINDOW ASSEMBLY.
SEALANT 4 BACKER ROD
WINDOW JAMB
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
TRIM- MATCH (E) TRIM. PRIME ALL SIDES m
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMNED
UNDETERMNED VNYL SIDING SUBSTRATE
CAREFULLY REMOVE TOP COURSES OF (E)
VINYL AND BACKER BOARD FOR
NSTALLATION OF WINDOW ASSEMBLY 4
TRIM. REPLACE/ RE- INSTALL SIDING TO
MATCH (E)
(E) VNYL SIDING
WINDOW SILL
SELF - ADHERING MEMBRANE
LAP OVER (E) WALL
UNDERLAYMENT 4 ".
CONTNUOUS SEALANT, TYP.
LAP SELF ADHERING
MEMBRANE AT JAMBS
OVER TOP OF SILL
MEMBRANE EXTENSIONS
(E) GWB
VINYL SIDING - WINDOW DETAIL SET
3 " =1' -0"
WINDOW SCHEDULE
WINDOW
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
REMARKS
DETAIL SET
A
ENTRY
KITCHEN
Ii
2
1' -9" x 2' -7"
2'-4" x 3' -10"
STAIN /PAINT
STAIN /PAINT
SECONDARY WINDOW
2/A2.0
B
C
KITCHEN
2
2' -4" x 3' -10"
STAIN /PAINT
2/A2.0
D
KITCHEN
3
2' -8" x 2' -9"
STAIN /PAINT
2/A2.0
E
KITCHEN
3
2' -8" x 2' -9"
STAIN /PAINT
GARDEN WINDOW
3/A2.0
F
KITCHEN
4
3' -0" x 3' -10"
STAIN /PAINT
2/A2.0
G
DINING
5
5' -9" x 5' -4"
STAIN /PAINT
2/A2.0
H
LIVING
3
1' -9" x 1' -11"
STAIN /PAINT
2/A2.0
I
LIVING
3
1' -9" x 1' -11"
STAIN /PAINT
2/A2.0
J 1
LIVING
3
2' -11" x 5-4"
STAIN /PAINT
2/A2.0
K
LIVING
3
2' -11" x 5' -4"
STAIN /PAINT
2/A2.0
L
STAIR
2
2' -4" x 4' -9"
STAIN /PAINT
SAFETY GLAZING
2/A2.0
M
BEDROOM 1
6
2' -0" x 4' -9"
STAIN /PAINT
2 /A2.0
N
BEDROOM 1
6
2' -0" x 4' -9"
STAIN /PAINT
21A2.0
0
CLOSET
3
2' -2" x 3' -0"
STAIN /PAINT
SAFETY GLAZING
21A2.0
P
BEDROOM 2
6
2' -0" x 4' -9"
STAIN /PAINT
2/A2.0
Q
BEDROOM 2
6
2' -0" x 4' -9"
STAIN /PAINT
2/A2.0
R
CLOSET
3
2' -2" x 3' -0"
STAIN /PAINT
SAFETY GLAZING
2/A2.0
S
BEDROOM 3
7
4' -9" x 4' -9"
STAIN /PAINT
2/A2.0
T
CLOSET
3
2' -2" x 3' -0"
STAIN /PAINT
SAFETY GLAZING
2 /A2.0
U
BEDROOM 4
7
11' -2" x 3' -5"
STAIN /PAINT
36" / 60" / 36" W/ 12" WOOD MULLIONS BETWEEN
2/A2.0
V
CLOSET
3
2' -2" x 3' -0"
STAIN /PAINT
SAFETY GLAZING
2/A2.0
W
STAIR
3
2' -10" x 1' -9"
STAIN /PAINT
SAFETY GLAZING
1/A2.0
X
OFFICE
3
2' -11" x 1' -9"
STAIN /PAINT
2/A2.0
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) GOB
CONTINUOUS
f — SEALANT, TYP.
CAREFULLY CUT BACK (E) SIDING TO
ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADI -ERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. NSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER I-1EADS
AND ANY CRACKS WHICH DEVELOP N
SIDING FROM INSTALLATION OF
FLASHING
(E) SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PANT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
REPLACEMENT
WINDOW ASSEMBLY
PER SCHEDULE AND
SPECIFICATION
BACKER ROD 4 SEALANT
REPLACEMENT
Cra
ral
WINDOW HEAD
X11
WL .L• l,.
Wm—mVutaiiiiL
w
SOLID WOOD TRIM
WD. JAM8 LNNG. FNISH TO
MATCH (E)
SEALANT 4 BACKER ROD
REPLACEMENT WINDOW
ASSEMBLY PER SCHEDULE
AND SPECIFICATION
WINDOW JAMB
WINDOW ASSEMBLY
PER SCHEDULE AND
SPECIFICATION
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) SIDING FOR
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING AS
REQ'D TO MAINTAIN COURSING 4 PAINT
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) GWB
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
BACKER ROD 4 SEALANT
3/4" WD. SILL - STAIN TO
/4" MATCH (E)
WINDOW SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
SELF - ADHERING MEMBRANE
(E) GWB
GARDEN - WINDOW DETAIL SET
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 17 2012
City of Tukwila
BUILDING DIVISION
FEB 07 2012
37
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
rn ,
SCOTT EmF'F
STATE 0 ► NIN TON
0810.03.2035
9/20/11
CC
0
0_
J
z
O
I--
z
W
Z
F-
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
3-53 -0058 -044
z
O
0
z_
f—
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2035
DOOR TYPES
A
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
FLUSH SCW FLUSH SCW
HALF -LITE W/
2 PANELS
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH INT. /EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK SET
DETAIL SET
1
ENTRY
A
3' -0" x 6' -9"
PAINT /PAINT
HW -1/609
DK -4
(CAMELOT)
LOCK -1
1/A2.1
2
KITCHEN
B
2' -8" x 6' -8"
PAINT /PAINT
HW -1/613
DK -4
(ADDISON)
LOCK -1
1/A2.1
3
FAMILY ROOM (INTERIOR)
C
3' -0" x 6' -8"
PAINT /PAINT
HW -2/606
DK -1
N/A
2/A2.1
4
ENTRY
D
3' -0" x 6' -9"
1/A2.1
5
KITCHEN
D
2' -8" x 6' -8"
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT
ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT
CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS
SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
(E) VNYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VNYL SIDING AS REQ'D FOR
NSTALLATION OF DOOR ASSEMBLY 4
TRIM. REPLACE W/ NEW SIDING,
ACCESSORIES, 1 BLOCKING TO MATCH (E)
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM POOR PER SCHEDULE
SHIM BACKER BOARD AS
REQUIRED
(E) EXTERIOR SHEATHING
1 CONTNUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATI -{ER-
STRIPPING
DOOR PER SCHEDULE
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF ADHERING
MEMBRANE 4" UP WALL FROM TOP OF
FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL AS REQ'D FOR
INSTALLATION OF DOOR ASSEMBLY 4 TRIM.
REPLACE W/ NEW SIDING, ACCESSORIES, 1
BLOCKNG TO MATCH (E)
CONTINUOUS SEALANT BEHND Z BAR
FRAME
STORM DOOR PER SCHEDULE
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
1" MIN.
DOOR SWEEP
ALUMNUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
DOOR HEAD
(E) EXTERIOR SHEATHING
(E) BACKER BOARD
SHIM BACKER BOARD
AS REQUIRED
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
CONTINUOUS SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR JAMB
DOOR SILL
VINYL SIDING - DOOR DETAIL SET
3 " =1' -0"
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KEW IN CONTINUOUS
WEATHER STRIPPING
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
(E)) " GWB
DOOR HEAD
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
INTERIOR DOOR PER
SCHEDULE
KERF IN CONTINUOUS
WEATHER STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR SHOE
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
DOOR JAMB
EXISTING FLOOR STRUCTURE
DOOR SILL
EXISTING FRAMING
CONTINUOUS
SEALANT, 1YP.
SOLID WOOD TRIM
DOOR PER SCHEDULE
INTERIOR - DOOR DETAIL SET
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 17 2012
City of Tukwila/
BUILDING DIVISION
FEB 07 2012
Da-o33
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
-_ .;CTER D
^. I EC.
h1r FI' CT N
0810.03.2035
9/20/11
0
Ct
a
J
Z
0
I-
<
z
w
F-
z
z
0
U
C�
Z
AIP NUMBER
MPROVEMENTS
0
w
w
w
0
Z
U
Q
J
Q
H
Z
W
D
Cn
W
3 -53- 0058 -044
z
0
1---
z_
Cn
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2035
(E) BACKER BOARD
(E) VINYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHNG. LAP (E) WALL UNDERLAYMENT
OYER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDING AS REQ'D FOR
INSTALLATION OF VENT FIXTURE 4
FLASHNG. REPLACE W/ NEW SIDING,
ACCESSORIES, 4 BLOCKING TO MATCH (E).
PRE - PRIMED, GALV SHEET METAL
FLASHING W/ FP. END CAPS UNDER
SURFACE MOUNTED REGLET AND GAP
FLASHING. PANT COLOR TO BE
SELECTED IN THE FIELD
PAINT VENTILATION FIXTURE,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MEC4.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
SHIM BACKER BOARD AS
REQUIRED
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
REPLACEMENT SIDING AS REQUIRED
EXIST. WALL
CONSTR.
(E) EXTERIOR SHEATHING
2X BLOCKING
2X2 BLOCKING, 4 SIDES
(P.T.)
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
(2) SIMPSON A -34
a EACH SIDE PANEL
OPEN TOP
EXIST. GABLE
VENT
NEW #" GALV.
HARDWARE
CLOTH
in CDX PLYWOOD
AT (3) SIDES
I" MEWS CORNING "103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
1. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
3 GABLE END VENT BAFFLE DETAIL
11/2 -1 -0
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
INSULATION DAM DETAIL
INSULATION
INSULATION DAM
(E) WALL FRAMING
3 " =1' -0"
EXISTING VENT COVER
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2 "X SPACER
LATERAL SECTION
b" MIN. TYPICAL TOP 4
BOTTOM
NEW 1" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
ROOF VENT BAFFLE DETAIL
1 1 /2" = 1 ' - 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 17 2012
•
City of` Tukwila
BUILDING DIVISION
FEB 07 2012
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
1000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
Rr G %STEED
HILC
TEMPH
3HINGTON
9/20/11
0810.03.2035
F-
OC
0
CIL
p Z
Q
w OO
O w o
c z
Z rw V)
<
w O
Z J_
LL :
I-
DD I-
0
U <
() J
Z <
Z
w
0
LZ mow�//
MPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
DATE
9120111
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
MISC.
DETAILS
A2.2
0810.03.2035
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK PROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 1 -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I i"
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
1 MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
5HOUJN FOR CLARITY.
(E) SHEATHNG
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOIUN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
5HEATHNG
1" MN
Jr 5" Jr
BUTTERFLY CORNER FLASHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
514OULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
ELEVATION VIEW
NOTE: NSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
UUNNDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
L J
HEAD FLASHING PREPARATION
WHERE RED IRED, TRIM
(E) BLDG ' APER AT
DEAD TO PARE
FOR INSTA LATION OF
HEAD FL - NG AND
WINDOW TR
(FOLLOWI ' STEPS).
/ SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOIbN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
2 MEMBRANE FLASHING AT JAMB
y SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 514T. METAL -
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW 118" ' • RANCE
BETWEEN ING AND
BOT. EDGE (E)
SIDING.
HEAD FLASHING INSTALLATION
.1 SCALE: NTS
(E) BLDG. PAPER
C--3 MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 51-IOtLN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT HEAD
FLASHNG 4 FOLD
AROUND UJNDOW
OPENNG AS
51-1OWN. EXTEND
1 -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHNG TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
INSTALL JAMB FLANGE FLASHING OVER WINDOW —
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
o
e
G
O
e
O
C
i
/
\
O O
O
ELEVATION VIEW
NOTE: NSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
UUNNDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
L J
HEAD FLASHING PREPARATION
WHERE RED IRED, TRIM
(E) BLDG ' APER AT
DEAD TO PARE
FOR INSTA LATION OF
HEAD FL - NG AND
WINDOW TR
(FOLLOWI ' STEPS).
/ SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOIbN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
2 MEMBRANE FLASHING AT JAMB
y SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 514T. METAL -
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW 118" ' • RANCE
BETWEEN ING AND
BOT. EDGE (E)
SIDING.
HEAD FLASHING INSTALLATION
.1 SCALE: NTS
(E) BLDG. PAPER
C--3 MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 51-IOtLN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT HEAD
FLASHNG 4 FOLD
AROUND UJNDOW
OPENNG AS
51-1OWN. EXTEND
1 -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHNG TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
INSTALL JAMB FLANGE FLASHING OVER WINDOW —
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WNDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
h MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF
ADHEARNG MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WNDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND S" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE V4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 7 2012
City of Tukwila
BUILDING DIVISION
FEB 07 2012
D t)- -037
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELPIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
h`C SfE:=? -D,
A,;I,E,.
v
EMPE
STATE i- .,HIND TOr
0810.03.2035
9/20/11
0
a.
J
z
O
Q
z
LU
z
z
O
U
0
z
AIP NUMBER
MPROVEMENTS
D
W
ce
W
W
0
ce
z
Z
W
3- 53- 0058 -044
z
0
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2035
i
/
INSTALL HEAD
FLANGE FLASHING
OVER WNDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
h MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF
ADHEARNG MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WNDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND S" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND
OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE V4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP AT ALL 4
SIDES.
WINDOW FLASHING INSTALLATION
SCALE: NTS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 7 2012
City of Tukwila
BUILDING DIVISION
FEB 07 2012
D t)- -037
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELPIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
h`C SfE:=? -D,
A,;I,E,.
v
EMPE
STATE i- .,HIND TOr
0810.03.2035
9/20/11
0
a.
J
z
O
Q
z
LU
z
z
O
U
0
z
AIP NUMBER
MPROVEMENTS
D
W
ce
W
W
0
ce
z
Z
W
3- 53- 0058 -044
z
0
z_
DATE
9/20/11
ISSUED BP M -27
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &SW
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2035
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
Cw
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
ARE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
0
ABBR
AC)
XX
OR ms,
0
X/Y
/ / / / / / / / //i
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT UNE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
--S f
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT UMITE
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
ADD ' = STEE
ORT
HANGERS,
SYMBOL
$G -X
XXX
ABBR
+ #
-mAC
y
+ r +
><1
49-F-
0
0-9
0 4*-
® OR
EQUIP ID A.-
x
NG
•
0
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
430
G08 "WG
8 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
150
430
G08 "WG
8 "0
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2035
2714
5
150 CFM
150 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE 1NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT HOURS OF OPERATION
SET THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
p 1/-037
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) Z .
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 75 / (1 X 1 /2) = 150 CFM
FEB 07 2012
SEPARATE
PEFOIT AND
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
Simm 200 • SEATTLE, WA 98108
(208) 624 -2777 • FAX (208) 1124 -8073
THE GREENBUSCH GROUP, INC
......01100
Aoousnrx, AUDIO VIDEO t !ROWED/ . omOEiw3
1000 VEST NICIOSMON SMELT ME 101 MODE 08 06110
(206) 378 -0889 (208) 378 -0041 FAX
0810.03.2035
O
a
J
Q
Z
0
z
w
H
z
z
0
v
c�
z
H
z
w
w
0
ce
a
0
w
w
w
O
z
Q
W
D
W
AIP NUMBER
3 -53 -0058 -044
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.2035
FLU E
VENT
w
D
- v
Z
41- 4
HOLD TIGHT TO
(E) DUCT
BASEMENT
SELF STANDING
SHELFTO MOVE
ARCH TO CUT
& PATCH WALL
FAMILY
ROOM
BASEMENT MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
CEILING
FLU E
NORTH
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
MOD, INTERLOCK
TO FURNACE
FLOOR
POC
V
J
cL
0
w
FURNACE
RETURN BEHIND
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
GAS
METER
KITCHEN
(E)SG
SG
BATI -I
DINING
LIVING
ROOM
(E)RG
2
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1 /A2.2 FOR DETAIL
WALL CAP INSTALLATION DETAIL
SCALE: NONE
NORTH
SAFETY
GLAZING
CLOSET
BEDROOM SG
2 E
BEDROOM
(E)SG
CLOSET
SAFETY
GLAZING
(E)SG
I I
SAFETY
GLAZING
CLOSET
(E)SG BEDROOM
3
BEDROOM
4
CLOSET
SAFETY
GLAZING
UPPER FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER WAC 51- 52- 0403.8.3.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
NORTH
Q P--037
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL
CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH
ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
Senipe
E% rr FEB 07 2012
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
REMOVE WALL TO INSTALL OA CONNECTION, THEN PATCH.
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(206) 624 -2777 • FAX (206) 624-2973
THE GREENBUSCH GROUP, INC
11111 16..)
NAP / & 111921ANKAL 1:11
1900 VW SMELT Butt 201 MIL 10
(206) 378 -0669 (206) 376 -0641 ROC
0810.03.2035
f-
Z
ctw
w
O OTC
ce
0
Q W
Z �
O
a Ct
LU
z W
Z
— t—
O
0 Q
C9
Z
~
Z
W
D
W
AIP NUMBER
3- 53- 0058 -044
TUKWILA WASHINGTON
DATE
9/16/11
ISSUED BID PACKAGE M -27
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2035
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
Q PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
03 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
EASEMENT
OFFICE
FAM I L'�
.oOM
BASEMENT PLAN
1/4" = 1'
NORTH
irL
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
UGHIING OR POWER PANEL
0
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE
#12 AWG, 1/2.C. MIN. EMT OR RIGID STEEL i INDICATES EQUIP GND.
} INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
NON -FUSED DISCONNECT SWITCH
❑S'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
SMOKE DETECTOR
ELECTRICAL METER
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
L'J
THERMOSTAT
DINING
MAIN FLOOR PLAN
1/4" = 1'
CEJUNG MOUNTED FIRE ALARM - VISUAL STROBE LIGHT
UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
15
16
15
16
N/A
15
16
N/A
-
MOTOR DAM PER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VER
2 - DISCONNECT
FY QUANTITY FROM PLANS (TYPICAL ALL)
SWITCH
4=E -rt
ZI G
I
5ED QOM
ICE BOOM
C O ET
I l
SAFETY"
L_ AZ INC
E,EIDIROOM
3
\1,
ISEDROOM
4
C_OSET
ATETi'
GLAZING
FEB 07 2012
SEPARATE 4
PERMIT AND
APPROVAL
rer,,,,R
•
S.MSTEMPER
ARCHITECTS
A Professional limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98166
(206) 624 -2777 • FAX (206) 624 -2973
!HUMMING. INC
0810.03.2035
NTERNATIONAL AIRPORT
KING COUNTY
AIP NUMBER
MPROVEMENTS
0
ce
w
w
w
0
z
J
W
W
5-53- 0058-043
z
0
z_
DATE
9/8/11
ISSUED M -27
100%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.O
0810.03.2035