Loading...
HomeMy WebLinkAboutPermit D12-037 - FERTAKIS RESIDENCE - UPGRADESFERTAKIS RESIDENCE 11822 42 AV S D12-037 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400225 Address: 11822 42 AV S TUKW Suite No: Project Name: FERTAKIS RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -037 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: FERTAKIS JON E +MARY E Address: 11822 42ND AVE S , SEATTLE WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION .AND ABATEMENT). Value of Construction: $44,378.00 Fees Collected: $1,460.87 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7110 D12 -037 Printed: 03 -20 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Zee 6" ye9 o" 7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12 -037 Printed: 03 -20 -2012 this requirement. • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -037 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukivi/a.wa. us Building Perim ? o. b (d- -6 3 7 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 11822 42nd Avenue S. Tenant Name: Jon E. and Mary E. Fertakis Property Owners Name: Jon E. and Mary E. Fertakis Mailing Address: 11822 42nd Avenue S. King Co Assessor's Tax No.: 3347400225 Suite Number: New Tenant: Floor: ❑ Yes al ..No 98168 Zip Tukwila WA City State CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: H:Wppluations\Forms- Applications On Ltne\2009 Applications \I-2009 - Penuit Applicanon.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 44,378 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm l None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach fist of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HP,Applications'•Forms- Applications On Line,2009 Applications'•.I -2009 - Permit Application.doc Revised: t -2009 bh Page 2 of 6 Existing • Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 810 2nd Floor 690 3'a Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm l None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach fist of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HP,Applications'•Forms- Applications On Line,2009 Applications'•.I -2009 - Permit Application.doc Revised: t -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR T, <<, IZED AGENT: Signature: I ► EI Print Name: Day Telephone: Date: l Z Mailing Address: City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPINOTRMIT INFORMATION — 206 -4 670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Cod Occupancy (per lnt'l Building Code): Utility Purveyor: Water: ewer: Indicate type of plumbing fixtures and/or gas pipin outlets being in , lled and the quantity below: Fixture Type: Qty Fixture Type: Qty '' ixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet ." Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) '' r' t Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory " Wash fountain Receptor, indirect waste Sinks Urinals �' `.ter Closet `+. Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/: vent / Ind ''. ,, 'al waste treatment intercotor, including trap and ven \except for kitchen type rea\ interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or ;�` eration of water pi y` g and/or water treatm =; t equipment Repair or a i;a . tion of drainage or v piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outsets greater than 5 Ba : " ow protective d ;'ice other than ospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protecti :, device other than atmosphe , -type vacuum breakers over inch (51 mm) diameter `1: °a Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:,Applications 'Forms- Applications On- Linei2009 Applicationsll -2009 Permit Application :doe Revised: 1 -2009 bh Page 5 of 6 Ci f of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: ht4i : //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17, 659.72 INSPECTION RECORD Retain a copy with permit INSPECTION'NO. PERMIT NO. CITY OF TUKWILA BUILDING QIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 2" (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro e"T ti,& A.---017 TYPe . 10 A- ... 0 Address: )[t��``L.�..., -1 7:61 Date Called: Speciallnstructions: Date Wanted: t f ,{ p.m: Requester: Piton�° Approved per applicable codes. Corrections required prior to approval COMMENTS: Insp ctor: Dace:. • n REINSPECTION FEE REQUIRE . for to next inspection fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute'reinspection. City of Tukwila 21 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANRIP Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers D12 -025 through D12 -039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. File: Permit No. DI2 -025 through D12 -039 W \Permit Center\Extension Letters\Pemiits\2012\D12 -025 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 S.M. STEMPER ARCHITECTS A P r o ( e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y 13 September 2012 Bill Rambo, Permit Technician City of Tukwila, Department ofCommunity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Rambo, This letter serves as written request to extend the permits listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RANRIP). Permit Address Permit Number Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034 5003 S. l 13th St. D12 —027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 — 036 5023 S. 124th St. D12 — 029 11822 42nd Ave S. D12-037 11602 40th Ave S. D12 — 030 12507 50th PIS. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039 12203 47th Ave S. D12 — 032 Permits for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original permits. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 - 721 -0061 or tfenlason@onespayne.com. (,,A, . /4. :c16o 4/4bevtizei. c/Z 00 /Z Timothy J. Fenlason Project Manager The Jones Payne Group, Inc. CITY OF TUKWItA SP 13 20121 PERMIT CENTER t\cP 01W112 4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106 • 206/ 624 -2777 . FAX 206/ 624 -2973 tjG 417\1c1/1-, 10 -01 -2012 City of'Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -037 FERTAKIS RESIDENCE 11822 42 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumping Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, V4-111( r Marshall Technician File: Permit File No. D 12 -037 6300 SouthcenterBoulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431 -3665 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -037 FERTAKIS RESIDENCE 11822 42 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, File: Permit File No. D12 -037 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 411) Gtt 5. ti PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -037 PROJECT NAME: FERTAKIS RESIDENCE SITE ADDRESS: 11822 42 AV S X Original Plan Submittal Response to Correction Letter # DATE: 02 -07 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: —l3. ding Public Work s Fire Prevention Structural a NIA IP Planning Division Permit Coordinator IL] DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -09-12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -08 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00677C11 BID PACKAGE M -27 3- 53- 0058 -044 vim` EF F TE PERMIT R=OC' ED FOR: fieChanicai t ectricai pry6mbing U Gas POMO City of Tukwila BUILDING DIVISION FILE COPY Permit No., \')- CA1 P4 rc 4sw approval Is subject to errors and omisskms, i; t ,ai of construction documents does not authorize :, ,),a4jon of any adopted code or ordinance. Receipt o; Lp;praysd Field Copy and conditions is acknowledged: By Date: , City Of T'llkwita BUILDING DIVISION REVISIONS t:'n chengas shall be made to the scope c i l 'onrk without prior approval of ;.0 ` <17;la Building Division. wiz require a new plan submittal ,„„ may in .:ude additional plan review fees. b12 037 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 ity of Tukwila BUILDING DIVISION FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 international Residential Code, international Fire Code, International Mechanical Code 3341400225 LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV 01 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v 5 NON SPRINKLEREP DRAWING INDEX T0.0 AI.O A2.0 A2.I 422 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX Mao MECHANICAL PLANS AND DETAILS Ei.O ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 2%. 0190 Contact: Sheryl Parker E- mail: Sharyn.Parkerekingcounty.gov ARCHITECT: S.M. Stamper Architects PL.L.C. 4000 Pslridge Way 5W, Suite 200 Seattle, WA 98106 Ph 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryesmstemper.com melodyesmstempercom timesmstemper.com ACOUSTICAL ENGINEER 554 Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E -mail: mohame:dessaacousticscom MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E -mail: Dylantegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: rim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washinnggton St. 0200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E-mail: JCornwelleJonespayne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepsm- engineers.com SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. UD NG BUT NOT LIMITED CONTRACT ALL INFORMATION IN THE DRAWINGS AND APPLICABLE YES NO 1 SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL- FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFiLL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. y /� 9.5 INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. V /� 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. X 14. INSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC NSULATION. X ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 1000 DELRTDDE WAY SW SUITE 200 • SEATTLE, WA 08106 (206) 624 -2777 • FAX (206) 624 -2973 r;� -t''EG STERED • lill'f` 0810.03.2035 9/20/11 0 J Q 0 z W z z 0 U 0 z AIP NUMBER MPROVEMENTS 0 LLl W LLJ 0) 0 z LL 0 ce J z LLJ 0 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2035 p 037 a BASEMENT OFF ICE FAMILY ROOM LOWER FLOOR PLAN 1/8" = 1' SPECIAL NOTES: NOTE: TI-115 HOUSE HAS SFECFIC PANT COLORS. CONTRACTOR 51-1ALL AS51 IE 20 CUSTOM PAINT COLORS FOR INTERIOR PAINT MATCHING. NOTE: LEAD PANT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081. r� 24' -3" T 111111111111 4-1 24" x 30" EXIST ATTIC ACCESS PANEL k � Gfil 11 f „LIT. 17117 .. 1 I f 1Arrd cons 1 �J� f1 11 1 11 1 11 1 .11 f1 11 11 11 �- 1 REVIEWED FOR CODE COMPLIANCE APPROVED L 1 UPPER FLOOR PLAN 1/4" = 1' GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW I5 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT NE END OF EACH WORK DAY. . PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WIN (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQD MD RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING.. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS 14ATCHE5. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILNG FNIS1-ES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.O FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EID FOR LOCATIONS AND DETAILS OF NTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIh'pM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. ! AFTER 55.00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18 DO NOT INSTALL NEW DOORS OR WINDOWS WERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATNG, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERNGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST SE PROVIDED. NORTH A. WEST ELEVATION B. NORTH ELEVATION PLAN KEYNOTES O DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WNDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. O DOOR SCHEDULE. DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH O MECHANICAL DOCUMENTS. 0 REMOVE (E) GARDEN BOX WINDOW, INSTALL ACOUSTICAL GARDEN BOX WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 O DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SI EET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET. 0 DEMOLISH EXISTING WALL CONSTRUCTION TO ALLOW MECHANICAL DUCT INSTALLATION. INSTALL WALL PATCH TO MATCH ADJACENT EXISTING CONSTRUCTION. COORDINATE WITH MECHANICAL DOCUMENTS. O REMOVE AND REINSTALL EXISTING SHELF TO ALLOW MECHANICAL DUCT INSTALLATION. O INSTALL VENT BAFFLE(S) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/A22 FOR DETAIL. O INSTALL VENT BAFFLE(S) At EXISTING ROOF VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL. 10 INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. 11 INSTALL SECONDARY WINDOW. REF. WINDOW SCHEDULE. 12 NSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWER 13 INSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVNG MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVNG METAL FIREBOXES. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. EAST ELEVATION ATTIC PLAN FEB 17 2012 1/8" = 1' City of Tukwila BUILDING DIVISION D. SOUTH ELEVATION LEGEND LE l L1 ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW GABLE END VENT BAFFLE RIDGE VENT BAFFLE FEB 072012 FEATHER TEXTURED CEILING OVER AT A i MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. 1 REF. MECH. t ELECT. a REF. GENERAL NOTE 11 ATTIC INSULATION SD INSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTING gams, • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 AEG %STEEr 4H LC COTT trt1PEk' STATE 0 HIN TOf 0810.03.2035 9/20/11 LL. 0 0 J z 0 Z W F-- Z H z 0 U z AIP NUMBER MPROVEMENTS 0 cnw w w 0 z U ce CA 3-53- 0058 -044 z O 1— DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2035 WINDOW TYPES FIXED OVAL 2. SINGLE HUNG OR DOUBLE HUNG 1. CASEMENT /FIXED / CASEMENT t 3. FIXED 4. GARDEN WINDOW SINGLE HUNG SIDES SLIDER / FIXED / SLIDER L CASEMENT / FIXED / CASEMENT /TRANSOM ABOVE CASEMENT TYPICAL WINDOW SCHEDULE NOTES NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING: FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE- NSTALL SIDING 4 ACCESSORIES TO MATCH (E). PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADI-ERNG MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD UNDETERMINED VNYL SIDING SUBSTRATE VINYL J CHANNEL TRIM WINDOW HEAD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WNDOW ASSEMBLY. SEALANT 4 BACKER ROD WINDOW JAMB OH_ (E) GWB (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE REMOVE AND RENSTALL (E) CABINETRY AS NECESSARY SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. NSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) GWB REMOVE AND REINSTALL (E) CABINETRY AS CESSARY Wp. JAMB LNNG. FNISH TO MATCH (E) BACKER ROD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES ,° AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR INSTALLATION OF WNDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) (E) BACKER BOARD (E) VINYL SIDING SEALANT 4 BACKER ROD 1 1 1 SOLID WOOD TRIM SELF- ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT CONTINUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" UNDETERMNED VINYL SIDING SUBSTRATE (E) BACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST 51-EATHNG. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE- INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM PRE- PRIMED, GALv SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT (E) WD. PANELING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. TRIM - MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD UNDETERMINED VINYL SIDING SUBSTRATE VNYL J CHANNEL TRIM I 1 WINDOW HEAD SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) vNYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) WD. PANELING CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT 4 BACKER ROD WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES m AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED UNDETERMNED VNYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR NSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) (E) VNYL SIDING WINDOW SILL SELF - ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". CONTNUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" WINDOW SCHEDULE J t L ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. CASEMENT / FIXED / CASEMENT /TRANSOM ABOVE CASEMENT TYPICAL WINDOW SCHEDULE NOTES NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING: FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE- NSTALL SIDING 4 ACCESSORIES TO MATCH (E). PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADI-ERNG MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD UNDETERMINED VNYL SIDING SUBSTRATE VINYL J CHANNEL TRIM WINDOW HEAD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WNDOW ASSEMBLY. SEALANT 4 BACKER ROD WINDOW JAMB OH_ (E) GWB (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE REMOVE AND RENSTALL (E) CABINETRY AS NECESSARY SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. NSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) GWB REMOVE AND REINSTALL (E) CABINETRY AS CESSARY Wp. JAMB LNNG. FNISH TO MATCH (E) BACKER ROD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES ,° AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED VINYL J CHANNEL TRIM UNDETERMINED VINYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR INSTALLATION OF WNDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) (E) BACKER BOARD (E) VINYL SIDING SEALANT 4 BACKER ROD 1 1 1 SOLID WOOD TRIM SELF- ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT CONTINUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" UNDETERMNED VINYL SIDING SUBSTRATE (E) BACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST 51-EATHNG. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE- INSTALL SIDING 4 ACCESSORIES TO MATCH (E). VINYL J CHANNEL TRIM PRE- PRIMED, GALv SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT (E) WD. PANELING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. TRIM - MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD UNDETERMINED VINYL SIDING SUBSTRATE VNYL J CHANNEL TRIM I 1 WINDOW HEAD SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) vNYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) WD. PANELING CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT 4 BACKER ROD WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES m AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED UNDETERMNED VNYL SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR NSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) (E) VNYL SIDING WINDOW SILL SELF - ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". CONTNUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A ENTRY KITCHEN Ii 2 1' -9" x 2' -7" 2'-4" x 3' -10" STAIN /PAINT STAIN /PAINT SECONDARY WINDOW 2/A2.0 B C KITCHEN 2 2' -4" x 3' -10" STAIN /PAINT 2/A2.0 D KITCHEN 3 2' -8" x 2' -9" STAIN /PAINT 2/A2.0 E KITCHEN 3 2' -8" x 2' -9" STAIN /PAINT GARDEN WINDOW 3/A2.0 F KITCHEN 4 3' -0" x 3' -10" STAIN /PAINT 2/A2.0 G DINING 5 5' -9" x 5' -4" STAIN /PAINT 2/A2.0 H LIVING 3 1' -9" x 1' -11" STAIN /PAINT 2/A2.0 I LIVING 3 1' -9" x 1' -11" STAIN /PAINT 2/A2.0 J 1 LIVING 3 2' -11" x 5-4" STAIN /PAINT 2/A2.0 K LIVING 3 2' -11" x 5' -4" STAIN /PAINT 2/A2.0 L STAIR 2 2' -4" x 4' -9" STAIN /PAINT SAFETY GLAZING 2/A2.0 M BEDROOM 1 6 2' -0" x 4' -9" STAIN /PAINT 2 /A2.0 N BEDROOM 1 6 2' -0" x 4' -9" STAIN /PAINT 21A2.0 0 CLOSET 3 2' -2" x 3' -0" STAIN /PAINT SAFETY GLAZING 21A2.0 P BEDROOM 2 6 2' -0" x 4' -9" STAIN /PAINT 2/A2.0 Q BEDROOM 2 6 2' -0" x 4' -9" STAIN /PAINT 2/A2.0 R CLOSET 3 2' -2" x 3' -0" STAIN /PAINT SAFETY GLAZING 2/A2.0 S BEDROOM 3 7 4' -9" x 4' -9" STAIN /PAINT 2/A2.0 T CLOSET 3 2' -2" x 3' -0" STAIN /PAINT SAFETY GLAZING 2 /A2.0 U BEDROOM 4 7 11' -2" x 3' -5" STAIN /PAINT 36" / 60" / 36" W/ 12" WOOD MULLIONS BETWEEN 2/A2.0 V CLOSET 3 2' -2" x 3' -0" STAIN /PAINT SAFETY GLAZING 2/A2.0 W STAIR 3 2' -10" x 1' -9" STAIN /PAINT SAFETY GLAZING 1/A2.0 X OFFICE 3 2' -11" x 1' -9" STAIN /PAINT 2/A2.0 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) GOB CONTINUOUS f — SEALANT, TYP. CAREFULLY CUT BACK (E) SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADI -ERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. NSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER I-1EADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REPLACEMENT WINDOW ASSEMBLY PER SCHEDULE AND SPECIFICATION BACKER ROD 4 SEALANT REPLACEMENT Cra ral WINDOW HEAD X11 WL .L• l,. Wm—mVutaiiiiL w SOLID WOOD TRIM WD. JAM8 LNNG. FNISH TO MATCH (E) SEALANT 4 BACKER ROD REPLACEMENT WINDOW ASSEMBLY PER SCHEDULE AND SPECIFICATION WINDOW JAMB WINDOW ASSEMBLY PER SCHEDULE AND SPECIFICATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) GWB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO /4" MATCH (E) WINDOW SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF - ADHERING MEMBRANE (E) GWB GARDEN - WINDOW DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 37 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 rn , SCOTT EmF'F STATE 0 ► NIN TON 0810.03.2035 9/20/11 CC 0 0_ J z O I-- z W Z F- z 0 U 0 z AIP NUMBER MPROVEMENTS 3-53 -0058 -044 z O 0 z_ f— DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2035 DOOR TYPES A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW FLUSH SCW HALF -LITE W/ 2 PANELS W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY A 3' -0" x 6' -9" PAINT /PAINT HW -1/609 DK -4 (CAMELOT) LOCK -1 1/A2.1 2 KITCHEN B 2' -8" x 6' -8" PAINT /PAINT HW -1/613 DK -4 (ADDISON) LOCK -1 1/A2.1 3 FAMILY ROOM (INTERIOR) C 3' -0" x 6' -8" PAINT /PAINT HW -2/606 DK -1 N/A 2/A2.1 4 ENTRY D 3' -0" x 6' -9" 1/A2.1 5 KITCHEN D 2' -8" x 6' -8" 1/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. (E) VNYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VNYL SIDING AS REQ'D FOR NSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 1 BLOCKING TO MATCH (E) PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM POOR PER SCHEDULE SHIM BACKER BOARD AS REQUIRED (E) EXTERIOR SHEATHING 1 CONTNUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATI -{ER- STRIPPING DOOR PER SCHEDULE CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 1 BLOCKNG TO MATCH (E) CONTINUOUS SEALANT BEHND Z BAR FRAME STORM DOOR PER SCHEDULE HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 1" MIN. DOOR SWEEP ALUMNUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR HEAD (E) EXTERIOR SHEATHING (E) BACKER BOARD SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR JAMB DOOR SILL VINYL SIDING - DOOR DETAIL SET 3 " =1' -0" SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEW IN CONTINUOUS WEATHER STRIPPING SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING (E)) " GWB DOOR HEAD CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM INTERIOR DOOR PER SCHEDULE KERF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD DOOR JAMB EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMING CONTINUOUS SEALANT, 1YP. SOLID WOOD TRIM DOOR PER SCHEDULE INTERIOR - DOOR DETAIL SET 3 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila/ BUILDING DIVISION FEB 07 2012 Da-o33 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 -_ .;CTER D ^. I EC. h1r FI' CT N 0810.03.2035 9/20/11 0 Ct a J Z 0 I- < z w F- z z 0 U C� Z AIP NUMBER MPROVEMENTS 0 w w w 0 Z U Q J Q H Z W D Cn W 3 -53- 0058 -044 z 0 1--- z_ Cn DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2035 (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHNG. LAP (E) WALL UNDERLAYMENT OYER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHNG. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PRE - PRIMED, GALV SHEET METAL FLASHING W/ FP. END CAPS UNDER SURFACE MOUNTED REGLET AND GAP FLASHING. PANT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MEC4.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. SHIM BACKER BOARD AS REQUIRED SELF ADHERING BITUMINOUS MEMBRANE FLASHING REPLACEMENT SIDING AS REQUIRED EXIST. WALL CONSTR. (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 BLOCKING, 4 SIDES (P.T.) 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" (2) SIMPSON A -34 a EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW #" GALV. HARDWARE CLOTH in CDX PLYWOOD AT (3) SIDES I" MEWS CORNING "103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: 1. AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. 3 GABLE END VENT BAFFLE DETAIL 11/2 -1 -0 EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL INSULATION INSULATION DAM (E) WALL FRAMING 3 " =1' -0" EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION b" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1 1 /2" = 1 ' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 • City of` Tukwila BUILDING DIVISION FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 1000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 Rr G %STEED HILC TEMPH 3HINGTON 9/20/11 0810.03.2035 F- OC 0 CIL p Z Q w OO O w o c z Z rw V) < w O Z J_ LL : I- DD I- 0 U < () J Z < Z w 0 LZ mow�// MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 9120111 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2035 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK PROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL 1 MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT 5HOUJN FOR CLARITY. (E) SHEATHNG CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOIUN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL 5HEATHNG 1" MN Jr 5" Jr BUTTERFLY CORNER FLASHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT 514OULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. ELEVATION VIEW NOTE: NSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION MEMBRANE FLASHING PREVIOUSLY APPLIED TO UUNNDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r L J HEAD FLASHING PREPARATION WHERE RED IRED, TRIM (E) BLDG ' APER AT DEAD TO PARE FOR INSTA LATION OF HEAD FL - NG AND WINDOW TR (FOLLOWI ' STEPS). / SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOIbN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 MEMBRANE FLASHING AT JAMB y SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL 514T. METAL - HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 118" ' • RANCE BETWEEN ING AND BOT. EDGE (E) SIDING. HEAD FLASHING INSTALLATION .1 SCALE: NTS (E) BLDG. PAPER C--3 MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51-IOtLN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT HEAD FLASHNG 4 FOLD AROUND UJNDOW OPENNG AS 51-1OWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHNG TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) INSTALL JAMB FLANGE FLASHING OVER WINDOW — NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS o e G O e O C i / \ O O O ELEVATION VIEW NOTE: NSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION MEMBRANE FLASHING PREVIOUSLY APPLIED TO UUNNDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r L J HEAD FLASHING PREPARATION WHERE RED IRED, TRIM (E) BLDG ' APER AT DEAD TO PARE FOR INSTA LATION OF HEAD FL - NG AND WINDOW TR (FOLLOWI ' STEPS). / SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOIbN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 MEMBRANE FLASHING AT JAMB y SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL 514T. METAL - HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 118" ' • RANCE BETWEEN ING AND BOT. EDGE (E) SIDING. HEAD FLASHING INSTALLATION .1 SCALE: NTS (E) BLDG. PAPER C--3 MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51-IOtLN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT HEAD FLASHNG 4 FOLD AROUND UJNDOW OPENNG AS 51-1OWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHNG TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) INSTALL JAMB FLANGE FLASHING OVER WINDOW — NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL HEAD FLANGE FLASHING OVER WNDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: h MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WNDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND S" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE V4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 7 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 D t)- -037 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELPIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 h`C SfE:=? -D, A,;I,E,. v EMPE STATE i- .,HIND TOr 0810.03.2035 9/20/11 0 a. J z O Q z LU z z O U 0 z AIP NUMBER MPROVEMENTS D W ce W W 0 ce z Z W 3- 53- 0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2035 i / INSTALL HEAD FLANGE FLASHING OVER WNDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: h MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WNDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND S" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND OR INSTALL NEUJ SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE V4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 7 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 D t)- -037 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELPIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 h`C SfE:=? -D, A,;I,E,. v EMPE STATE i- .,HIND TOr 0810.03.2035 9/20/11 0 a. J z O Q z LU z z O U 0 z AIP NUMBER MPROVEMENTS D W ce W W 0 ce z Z W 3- 53- 0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2035 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD Cw DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT ARE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 0 ABBR AC) XX OR ms, 0 X/Y / / / / / / / / //i DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT UNE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION --S f EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT UMITE ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. ADD ' = STEE ORT HANGERS, SYMBOL $G -X XXX ABBR + # -mAC y + r + ><1 49-F- 0 0-9 0 4*- ® OR EQUIP ID A.- x NG • 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 430 G08 "WG 8 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 150 430 G08 "WG 8 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2035 2714 5 150 CFM 150 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE 1NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT HOURS OF OPERATION SET THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS. p 1/-037 MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) Z . &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 75 / (1 X 1 /2) = 150 CFM FEB 07 2012 SEPARATE PEFOIT AND EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW Simm 200 • SEATTLE, WA 98108 (208) 624 -2777 • FAX (208) 1124 -8073 THE GREENBUSCH GROUP, INC ......01100 Aoousnrx, AUDIO VIDEO t !ROWED/ . omOEiw3 1000 VEST NICIOSMON SMELT ME 101 MODE 08 06110 (206) 378 -0889 (208) 378 -0041 FAX 0810.03.2035 O a J Q Z 0 z w H z z 0 v c� z H z w w 0 ce a 0 w w w O z Q W D W AIP NUMBER 3 -53 -0058 -044 DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2035 FLU E VENT w D - v Z 41- 4 HOLD TIGHT TO (E) DUCT BASEMENT SELF STANDING SHELFTO MOVE ARCH TO CUT & PATCH WALL FAMILY ROOM BASEMENT MECHANICAL PLAN SCALE: 1 /4" = 1' -0" CEILING FLU E NORTH OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN MOD, INTERLOCK TO FURNACE FLOOR POC V J cL 0 w FURNACE RETURN BEHIND OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE GAS METER KITCHEN (E)SG SG BATI -I DINING LIVING ROOM (E)RG 2 MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL WALL CAP INSTALLATION DETAIL SCALE: NONE NORTH SAFETY GLAZING CLOSET BEDROOM SG 2 E BEDROOM (E)SG CLOSET SAFETY GLAZING (E)SG I I SAFETY GLAZING CLOSET (E)SG BEDROOM 3 BEDROOM 4 CLOSET SAFETY GLAZING UPPER FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51- 52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: NORTH Q P--037 CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. Senipe E% rr FEB 07 2012 FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. REMOVE WALL TO INSTALL OA CONNECTION, THEN PATCH. EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP, INC 11111 16..) NAP / & 111921ANKAL 1:11 1900 VW SMELT Butt 201 MIL 10 (206) 378 -0669 (206) 376 -0641 ROC 0810.03.2035 f- Z ctw w O OTC ce 0 Q W Z � O a Ct LU z W Z — t— O 0 Q C9 Z ~ Z W D W AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2035 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. Q PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 03 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. EASEMENT OFFICE FAM I L'� .oOM BASEMENT PLAN 1/4" = 1' NORTH irL ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION UGHIING OR POWER PANEL 0 BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE #12 AWG, 1/2.C. MIN. EMT OR RIGID STEEL i INDICATES EQUIP GND. } INDICATES ISOLATED GROUND. MAST, WEATHERHEAD EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON -FUSED DISCONNECT SWITCH ❑S' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. L'J THERMOSTAT DINING MAIN FLOOR PLAN 1/4" = 1' CEJUNG MOUNTED FIRE ALARM - VISUAL STROBE LIGHT UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A - MOTOR DAM PER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VER 2 - DISCONNECT FY QUANTITY FROM PLANS (TYPICAL ALL) SWITCH 4=E -rt ZI G I 5ED QOM ICE BOOM C O ET I l SAFETY" L_ AZ INC E,EIDIROOM 3 \1, ISEDROOM 4 C_OSET ATETi' GLAZING FEB 07 2012 SEPARATE 4 PERMIT AND APPROVAL rer,,,,R • S.MSTEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98166 (206) 624 -2777 • FAX (206) 624 -2973 !HUMMING. INC 0810.03.2035 NTERNATIONAL AIRPORT KING COUNTY AIP NUMBER MPROVEMENTS 0 ce w w w 0 z J W W 5-53- 0058-043 z 0 z_ DATE 9/8/11 ISSUED M -27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.O 0810.03.2035