HomeMy WebLinkAboutPermit D12-039 - LOFTUS DUPLEX - UPGRADESLOFTUS DUPLEX 12203 48 AV S D12-039 City o/i'ukwila Department of Communi ' Develo P ment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179001330 Address: 12203 48 AV S TUKW Suite No: Project Name: LOFTUS DUPLEX DEVELOPMENT PERMIT Permit Number: D12-039 Issue Date: 03/20/2012 Permit Expires On: 09/16/2012 Owner: Name: LOFTUS THOMAS j +MARTHA Address: 4918 S 122ND , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE, AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $43,421.00 Fees Collected: $1,436.29 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -039 Printed: 03 -20 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: oor-t-g- Date: Print Name: L « G This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12 -039 Printed: 03 -20 -2012 this requirement. • • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC-7/10 D12 -039 Printed: 03 -20 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Building Pe Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0179001330 Site Address: 12203 48th Avenue S. Suite Number: Floor: Tenant Name: Thomas J. and Martha Loftus New Tenant: ❑ Yes ®..No Property Owners Name: Thomas J. and Martha Loftus Mailing Address: 12203 48th Avenue S. Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Day Telephone: (206) 296 -7437 Mailing Address: 7277 Perimeter Road South Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Zip Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:Wpphcations\Ponns- Applications On Lme■2009 Applications \1-2009 - Permit Appltcanon.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ' ION — 206- 431 -3670 Valuation of Project (contractor's bid price): $ 43,421 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H,'Applicationa .Forms - Applications On Line12009 Applications,1 -2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 s< Floor 1,110 2 °d Floor PI Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H,'Applicationa .Forms - Applications On Line12009 Applications,1 -2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: Print Name: Mailing Address: N 7■1\i Date: & Z Day Telephone: o(4, - (v 2.-(4 Z��T City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications \Fortes - Applications On Lin■2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPINOERMIT INFORMATION — 206 - 4670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H: \ApplicationsForms- Applications On- Line1009 Applications 1-2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cii, of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206-431-3665 Web site: hrtn://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -00879 Initials: WER Payment Date: 03/01/2012 User ID: 1655 Total Payment: 17,659.72 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020712 SET NAME: KING COUNTY AIRPORT REMED SET TRANSACTIONS: Set Member Amount D12 -025 D12 -026 D12 -027 D12 -028 D12 -029 D12 -030 D12 -031 D12 -032 D12 -033 D12 -034 D12 -035 D12 -036 D12 -037 D12 -038 D12 -039 TOTAL: 993.76 1,313.36 1,313.36 1,042.93 993.76 1,239.61 1,411.70 993.76 1,387.12 1,165.85 811.18 905.73 1,460.87 1,190.44 1,436.29 993.76 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 17,659.72 TOTAL: 17, 659.72 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 10,661.95 000.345.830 6,930.27 640.237.114 67.50 TOTAL: 17,659.72 INSPECTION NO. INSPECTION RECORD Retain a copy with permit I 2-03S PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 TZ, (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: LOP' ItS ?!i L 7.. Type of Inspection: }' in.tA C. .,-420 .E--tt, Address: 12 ZO3 t-t � v\J S Date CaIje C,ot( rt. Special Instructions: / Date Wantedd:. j t t l j i 12 m„. p.m. Requester: -Phone N 6 `7 — I I 2.2 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector, !Date: f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. j ryi- I 7 /_ \,.11 �� \' II 1 I' r ��. .lyl I'__•1 `rt_ \ ..L U. )1) NORTHWET Emulation Certificate / Blower Door Test Form Batts and Blankets When installed in accordance with the manufacturers recommendations, Knauf batts and blankets will provide the full R- value. R- Vatue Minimum Thickness TO Obtain An insulation resistance (R- Value) of: Installed insulatinn should not be less than: R -38HD 10.25" R -38 12.00" R -30HD 8.25" R -30 10.00" R -26 9.00" R -22 6.50" R -21HD 5.50" R -19 6.25"" R -15HD 3.50" R -13 3.50" R -11 3.50" R -8 2.50" "R -18 in a 5.5" cavity. Con orris to ASTM 0665 and Federal Specification HH -I -521 F. Insulation Northwest LLC Rtl,riytL) CITY OF TIK►ri :P. A NOV 1 4 2012 Thermal Performance (Attic Application) PERMIT CENTE[f The stated thermal resistance (R- value) is provided by installing in accordance with the manufactuers instructions, the required number of _ bags per 1,000 sq.ft. of net area, at not less than the labeled minimum thickness. Failure to install both the required number of bags and at least the minimum thickness will result in lower insulation R- value. R- VaIue' To Obtain an insulation resistance (R- Value) of: Bags /1,000 sq. ft. I The number of bags /1.000 SF of net area should not be Maximum Coverage Contents of this bag should not cover more than: Minimum Weight The weight/SF of installed insulation should not be less than: Minimum Thickness Installed insulation should not be less than: R -60 31.7 31-5 SF .952 LBS 19.75" R -49 25 8 38.7 SF .774 LBS 16.75" R-44 22.1 45.3 SF .663 LBS 14.75" R -38 19.0 52.7 SF .569 LBS 13 -00" R -30 14.4 69.7 SF .431 LBS 10 -25" R -26 12.4 80.9 SF .371 LBS 9.00" R -22 10.4 95.8 SF .313 LBS 7.75" R -19 8.9 111.8 SF .268 LBS 6.75" R -13 6.1 164.3 SF .183 LBS 4.75" R -11 5.1 197.6 SF .152 LBS 4.00" Bag Weight - Nominal 30 lbs., Minimum 29 55. This product comforms to the performance requirements of ASTM C 764, Type I, and cancelled Federal Specification HH -I- 10308, Type I, Class B. R- Values are determined in accordance with C 687 and C 518. ' -R" means resistance to heat flow. The higher the R- value, the greater the insulation power_ To get the marked R- value. it is eseential that the insulation be installed properly. If you do it yourself. get instructions and follow them carefully. To achieve labeled R- value, this product must be applied with a pneumatic blowing machine and a corrugated hose with a minimum 25" internal corrugation, a minimum length of 150 ft and a diameter of at least 3-. Coils in the hose should not be less than 36" in diameter. Acceptable material feed rate is 5-35 lbs. /minute. Recommended feed rate 5 15 -25 lbs. / minute. Builders Insulation Statement Batts and/or blankets have been installed in conformance with the above recommendations to provide a thermal resistance of... 2009 WSEC Residential Energy Compliance Certificate - Building Air Leakage Building & Test Condition Comments Date: Time: Indoor Temperature: Outdoor Temperature: Floor Area (ft:) Affidavit: Bnildinp Air Leakage Target: SLA Less than 0.00030 Test #1 Depress . Press ._ Pretest Baseline Pressure:_, (Pa) Bldg Press. (Pa) Flow Ring R -Value I Standard Attic Area R- ,3J R-49 Sloped Ceilings R. R -38 Walls R. I R -21 Floors (over an unheated crawl space) R- 1 R -30 Completed as of: Site Address: Home Builder Signature: Home Builder Address: Insulation Contractor: /d /2.0 SO /2263 — 1-41P/04 � �4/' rel&iW /L./li, (.4/,q Insulation Northwest LLC P.O. Box 732069 Puyallup, WA 98373 Phone: (253) 846 -0121 Fax: (253) 846 -8096 Affidavit: Bnildinp Air Leakage Target: SLA Less than 0.00030 Test #1 Depress . Press ._ Pretest Baseline Pressure:_, (Pa) Bldg Press. (Pa) Flow Ring Fa (Pa)ss. Flow (cfm) Post -Test Pressure: . (Pa) Fan Model /SN: Results: SLA (Specific Leakage Area): Test #2 Depress._ Press._ Pretest Baseline Pressure: (Pa) Bldg Press. (Pa) Flow Ring Fan Press. (Pa) Flow (cfm) Post -Test Pressure: . (Pa) Fan Model /SN: Results: SLA (Specific Leakage Area): certify that this Specific Leakage Area is accurate and determined using Blower Door Test Standard 502.4.5 Building A :r Leakage Testing. Name Technician Signature 10 -01 -2012 City of'Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -039 LOFTUS DUPLEX 12203 48 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumping Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/15/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 11/15/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenni er WtylAidi er Marshall t Technician File: Permit File No. D12 -039 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 1, 2012 Timothy J. Fenlason S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extensions KCIA RANRIP Permits D12 -025 through D12 -039 Dear Mr. Fenlason, This letter is in response to your written request for an extension to Permit Numbers D12 -025 through D12 -039. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 60days from the date of expiration, November 15, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Je fer Mar e it echn File: Permit No. DI2 -025 through DI2 -039 W: \Pennit Center\Extension Lettcrs \Permits \2012 \M 2 -025 Permit Extension dnc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 S.M. STEMPER SI ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y 13 September 2012 Bill Rambo, Permit Technician City of Tukwila, Department ofCommunity Development 6300 Southcenter Boulevard, Suite 14100 Tukwila, WA 98188 RE: Bid Package M -27 Permits Dear Mr. Rambo, This letter serves as written request to extend the permits listed below, which are part of King County International Airport's (KCIA) Residential Airport Noise Remedy Improvements Program (RANRIP). Permit Address Permit Number Permit Address Permit Number 12223 48th Ave S. D12 — 025 5009 S. 112th St. D12 — 033 11666 42nd Ave S. D12 —026 4604 S. 122nd St. D12 — 034 5003 S. 113th St. D12 — 027 12222 47th Ave S. D12 — 035 12228 49th Ave. S. D12 — 028 12215 48th Ave S. D12 —036 5023 S. 124th St. D I2 — 029 11822 42nd Ave S. D12 —037 11602 40th Ave S. D12 — 030 12507 50th PI S. D12 — 038 11600 39th Ave S. D12 — 031 12203 48th Ave S. D12 — 039 12203 47th Ave S. D12 — 032 Permits for these properties were requested by our office as the homeowner's representative since this is a public project and is bid in accordance with grant requirements. A contract has been awarded and construction is in progress, but will not be complete by the end date of the original permits. Extension on all properties should be made for an additional 60 days. If you need further clarification or have questions, please contact me at 206 - 721 -0061 or tfenlason@onespayne.com. a 11 Ci 0 ZiS;:d C: i/lar4.Tadi P 9/2400/2 Sincerely, Timothy J. Fen lason Project Manager The Jones Payne Group, Inc. AkCEIvELY CITY OF TUKWILI4 P 13 2012 PERMIT CENTER e�P oiliull2 4000 DELRIDGE WAY SW . SUITE 200. SEATTLE, WA 98106 . 206/ 624 -2777 . FAX 206/ 624 -2973 t)6 14\ 'Ica 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D12 -039 LOFTUS DUPLEX 12203 48 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, File: Permit File No. D12 -039 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 PLANf•Nt444144 oit REVIEW/ROUTING SLIP ACTIVITY NUMBER: D12 -039 PROJECT NAME: LOFTUS DUPLEX SITE ADDRESS: 12203 48 AV S X Original Plan Submittal Response to Correction Letter # DATE: 02 -07 -12 Response to Incomplete Letter # Revision # After Permit Issued Fire PrevenA1AA 4)/A- i'D vision Fire Prevention Public Works Structural Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 02-09-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route M Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-08-12 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 0 • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/20/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - 00067701 1 BID PACKAGE M -27 3- 53- 0058 -044 SEPARATE PERMIT REQUIRED FOR: 12;echanicai E plyiectricat bing tJ Gas Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No pier rr.tWew approval is subject to errors and omissions. :E t of construction documents does not authorize of any adopted code or o` ordinance. Receipt 3t Lp rov ec Field Copy and conditions is acknowledged: By Date: /��-- City Of Tt,kwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work Without prior approval of 'Tukwila Building Division. i r7:':SOi1S>rrill require n efesittal `_" : y iric:ude aditional plary review fees. bIo39 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 VICINITY MAP (NTS) SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 0119001330 LEGAL DESCRIPTION: ALLENTOWN ADD ZONING: SFT200 OCSU)PANCY: 040 Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v B NON SPRINKLERED DRAWING INDEX TOD TITLE SWEET, PROJECT INFO. AI.O FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.I DOOR TYPES, SCHEDULE 4 DETAILS 422 MISCELLANEOUS DETAILS A23 WNDOW FLASHING DETAILS MI.O LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph 206. 263. 9233 Fax: 206. 296. 0190 Contact: Sharyn Parker E- mail: Sharyn.Parkerekingcounty .gov ARCHITECT: SM. Stamper Architects P.L.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 6.24. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Feniason, E -mail: Jerryesmstemper com melodyesmatemper.com tim,smstemper.com ACOUSTICAL ENGINEER: SSA, Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Fh 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E -ma11: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98405 Ph: 153. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E. Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: t1m ogclenepbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. '200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwellejonespayneccom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepem- engineers.com SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL ONINCLUDING VENTILATION. 14E NOT LIMITED CONTRACT METED TOUDES ALL INFORMATION IN THE DRAWINGS AND APPLICABLE YES NO 1 SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. NFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. NSTALLATION OF SECONDARY SLIDING STORM DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9A INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 9.B INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, PJ ACE MODIFICATION AND ASSOCIATED DUCTING. X 10. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 12. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 13. INSTALLATION OF CHIMNEY CAP. X 14. INSTALLATION OF SMOKE DETECTORS. X 15. REGULATED MATERIALS ABATEMENT. X 16. ATTIC VENT BAFFLES. X 11. INSTALLATION OF ATTIC INSULATION. X ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 .'COTT EMPE STATE liINGTON 0810.03.2038 9/20/11 F- ce 0 a_ ce J a z 0 NZ w 1- z z 0 0 Z MPROVEMENTS 0 cw w w 0) 0 z F- il AIP NUMBER 3 -53 -0058 -044 0 Z_ 5 f- DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN L B & SW PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2038 SPECIAL NOTES: NOTES: L ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE NDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR 514ALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRNG ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PANT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WNDOW TRIM PAINT. GENERAL NOTES L CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL WAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00 H. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT NE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVNG IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FNI51-1 AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVNG 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL LRJIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FNISI-ES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13, INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EIO FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE D FORE S:00 AM. 1 AFTER 3:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 15. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 15. EXISTING WNDOW COVERINGS MUST BE REINSTALLED ON NE SAME DAY AS COMPLETION OF WINDOW NSTALL. IF WNDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. MAIN FLOOR PLAN 1/4" = 1' NORTH A. WEST ELEVATION T 1- - FLR - ri Ir I • T[ �I II I 1 LI ri IL L 32' -4" - • • mows J B. NORTH ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF. ODOOR SCHEDULE. 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. 0 INSTALL SECONDARY SLIDING GLASS DOOR. REF. A2.1 FOR DOOR SCHEDULE. O INSTALL VENT BAFFLE(S) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 4/A22 FOR DETAIL. 0 INSTALL VENT BAFFLES) AT EXISTING ROOF VENT(5) IN ATTIC, REF. 5/422 FOR DETAIL 0 NSTALL NEW THERMOSTAT: COORDINATE WIN MECHANICAL DOCUMENTS. O O 10 11 ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. p ATTIC PLAN 1/4" = 1' C. EAST ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 7 2012 City of Tukwila BUILDING DIVISION D. SOUTH ELEVATION LEGEND O ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW GABLE END VENT BAFFLE RIDGE VENT BAFFLE FEB 07 201 FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILNG DEMOLITION FOR ATTIC PANEL i AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION . INSTALL BATTERY OPERATED SMOKE DETECTORS I w� KITCHEN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTING 2 • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 SuOTC ��� EP�fPE 5 rytiTC : = SHNGTON 0810.03.2038 9/20/11 0 0_ J 0 Q z LU z H z 0 U z AIP NUMBER MPROVEMENTS w w ce w O z U Q W D Cn 3-53 -0058 -044 z 0 H z_ Cn DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2038 WINDOW TYPES SLIDER 2. CASEMENT 3. FIXED WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A BEDROOM 1 1 4' -0" x 2' -11" STAIN /PAINT 1/A2.0 B KITCHEN 1 2' -11" x 3' -1" STAIN /PAINT 1/A2.0 C STUDY 1 3' -1" x 2' -8" STAIN /PAINT 2/A2.0 D LIVING 2 1' -9" x 3' -9" STAIN /PAINT 3/A3.0 E LIVING 3 3-8" x 3' -9" STAIN /PAINT 3/A3.0 F LIVING 2 1' -9" x 3' -9" STAIN /PAINT 3/A3.0 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGANST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR NSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND NSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CROCKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDNG (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING WINDOW HEAD LID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP WI BATT INSULATION BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN ----�_ TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED WINDOW JAMB (E) GWB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LNING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MANTAIN COURSING 4 PANT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL SACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTNUOUS SEALANT, TYP. SELF- ADI-IERNG MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF-ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T -III SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV 51-1EET METAL FLASHNG UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) T -111 SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. NSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM NSTALLATION OF. FLASHING (E) T -111 SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTNUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW HEAD (E) GWB ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -III SIDNG FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS RE= TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING WINDOW JAMB J WINDOW SILL 61-1111 AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADI-ERNG MEMBRANE (E) GWB T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" EXIST. SIDING (E) BAY CONSTRUCTION TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. WINDOW NAIL FIN, TYPICAL TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT Aussatincli FAIN III it 1' SELF- ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL. CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTRUCTION, TYPICAL SEALANT (2) LAYERS OF SELF- ADHERING WIND H E , TYPICAL BACKER ROD 4 SEALANT, TYPICAL ACOUSTICAL WINDOW ASSEMBLY WINDOW NAIL FIN, TYPICAL TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT, TYPICAL SOLID WOOD TRIM CAREFULLY REMOVE (E) SIDING FOR INSTALLATION OF WNDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN PANEL PATTERN 4 PAINT TO MATCH (E) SIDING, TYPICAL (E) GWB SILL AT BAY WINDOW SINGLE -FRAME WINDOW ASSEMBLY. BACKER ROD 4 SEALANT SELF- ADI -IERNG MEMBRANE WINDOW NAILNG FN BAY TRIM - PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM ALLOW 1/2" CLEARANCE TO WINDOW FRAME FOR SEALANT JOINT METAL BRACKET± MIN. (2) PER BAY APRON TO MATCH EXIST. SIDING WINDOW JAMB 2X WOOD LEDGER± INSTALL BLOCKING AT EXIST. WALL FOR ADDITIONAL SUPPORT IN N „I maw Air► emosimmaim nwil« \1 L --RP-if ` T � ....-.0t,,..41 .b...-qmsT I, II 1 1 IIi f CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL BACKER ROD ANS SEALANT EXIST. SIDING WINDOW SILL REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION BAY - WINDOW DETAIL SET 3 "= 1' -0" Do. 03, FEB 07 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 S i O[TT V� IEt4PE ti JNINGi JIv 0810.03.2038 9/20/11 0 0 ce J z 0 z W F— z 1— Z 0 0 AIP NUMBER MPROVEMENTS 0 ce cn w w w 0 LJ- z W 3-53 -0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2038 DOOR TYPES A FLUSH 5CW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW I LITE W/ 2 PANELS W/SAFETY GLAZING c SECONDARY SLIDING GLASS DOOR W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE `VxH FINISH INT. /EXT. HARDWARE SET/ FINISH KNOB 1 LEVER SET LOCK SET DETAIL SET 1 ENTRY A 3' -0" x 6' -8" STAIN /STAIN HW -1/609 DK -4 (CAMELOT) LOCK -1 1/A2.1 2 HALL B 2-8" x 6' -8" STAIN /STAIN HW -1/609 DK -3 (JUPITER) LOCK -1 1/A2.1 3 DINING C 8' -0" x 6' -8" STAIN /STAIN 2/A2.1 4 ENTRY D 3-0" x 6' -8" 1/A2.1 5 HALL D 2' -8" x 6' -8" 1/A2.1 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF- ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS LO-11C1-1 DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT NSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3" = 1' -0" (E) WD. SIDING PRE- PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF- ADI-ERNG MEMBRANE. PAINT COLOR TO BE SELECTED IN TI-E FIELD SELF- ADI- IERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE IS VISIBLE BELOW FLASHING EDGE 2X TAPERED CA REMOVE (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM D ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) WALL UNDERLAYMENT BACKER ROD AND SEALANT PLYWOOD DOOR HEAD PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. PAINT COLOR TO SE SELECTED IN THE FIELD CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PANT TO MATCH (E) TRIM SELF- ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR ll 1/2" MIN BETUIEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF - ADHERING MEMBRANE REMOVE (E) WOOD SIDING AND REPLACE AS REQ'D. CAREFULLY LIFT (E) WALL UNDERLATENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. EXTEND SELF- ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. AT HEAD AND JAMB (E) PRIMARY SLIDING DOOR ASSEMBLY. (E) BEVELED U. SIDING (E) EXTERIOR SHEATHING LIFT (E) WALL UNDERLAYMENT. LAP NEW I.NDERLAYMENT UNDER (E) UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME (E) PRIMARY SLIDING GLASS DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS SEALANT EXISTING SUBSTRATE (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING <:7 DOOR SILL WOOD SIDING - DOOR DETAIL SET 3 "= 11 -0" TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. Dig -a39 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 C.I :TT EMPE 0810.03.2038 9/20/11 0 J 0 z w 1— Z z 0 U 0 z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2038 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP. AT HEAD MD JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE t FLASHING. REPLACE W/ NEW SIDING PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV. SHEET METAL FLASHING W/ FF. END CAPS UNDER SELF- ADIERNG MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED N THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET N MASTIC AT EXTERIOR TRIM. REMOVE 1 REPLACE SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS EXIST. WALL CONSTR. INSULATION DAM DETAIL 3 " =1' -0" (2) SIMPSON A -34 • EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW i" GALV. HARDWARE CLOTH " CDX PLYWOOD AT (3) SIDES I" OWENS CORNING +103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL INSULATION INSULATION DAM (E) WALL FRAMING NOTE: I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS 114E EXISTING VENT OPENING. GABLE END VENT BAFFLE DETAIL 1 1/2 "= 1' -0" PIVOT HINGE CAULKING ADHESIVE INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS • 24" O.C. EXTEND BLOCKING TO (E) CEILING JOISTS (TYP) (E)GWB SNAP FRICTION CATCH REMOVABLE DOOR PAINT DOOR AND FRAME TO MATCH (E) COLOR OF CEILING ATTIC ACCESS PANEL DETAIL 3 " =1' -0" EXISTING VENT COVER EXISTNG ROOF STRUCTURE EXISTING ROOF VENT EXISTING ROOF STRUCTURE L 1 1 VeledreeleeloreVRAWAWIIMAI CROSS SECTION '1-'31) NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2"X SPACER LATERAL SECTION 6" MN. TYPICAL TOP t BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1 1/2" = 1' - 0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 tit • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 DroTT S1ATE 0 0IHINCT0L 9/20/11 0810.03.2038 1— O a. J z O Z w z 1— Z 0 0 MPROVEMENTS D ce W W W 0 ce z F— Z cn AIP NUMBER 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2038 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, T1'P. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOIIN FOR CLARITY. REPLACE AND OR INSEEN INSTALLED. NEW SIDNG AFTER MEMBRANE FLASHING HAS E 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 i" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHNG 4 FOLD THROUGH RO. AS 5HOWN. ADHERE MEMBRANE FLASHNG TO OUTSIDE FACE OF WALL 51-EATHING 1" MN MEMBRANE FLASHING AT SILL 5" i BUTTERFLY COMER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SI•IOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. WINDOW NAIL FLANGE. EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER .4T SILL_ l .Q B O O Q O O O C N O O O MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING REMOVED SCALE: NTS EDGE OF (E) SIDNG, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAY (E) BLDG PAPER BACK DOW OVER FLANGE FLASHING AT JAMBS L J HEAD FLASHING PREPARATION WHERE RE., IRED, TRIM (E) BLDG "'APER AT HEAD TO - PARE FOR INSTA LATION OF HEAD FLA NG AND WINDOW TR (FOLLOWI ' STEPS). SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDNG BACK FROM (E) ft AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOU,N. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1-145 BEEN INSTALLED. C-5- MEMBRANE FLASHING AT SILL / SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1/8" LEARANCE BETWEEN FL ING AND 130T. EDGE '' (E) SIDING. INSTALL 51-1T. METAL HEAD FLASHING UNDER (E) BLDG PAPER. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOW FOR CLARITY. 9 li HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND R.O. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFEREP TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS 'B, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1-145 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "a AND 9' REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JONTS. NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN NSTALLED. SHEET METAL HEAD FLASHING (E) SIDING SCALE: NTS E) BLDG. PAPER ENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JONT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPR!YFED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELPIDGE WAY SW SUITE 200 • SEATTLE, ti'A 98106 (206) 624 -2777 • FAX (206) 624 -2973 4220 REGISTERED —141111G1 1 .1 %1 /P!' > .( E EMf'E ,ETC r3- p u HNC-TON 0810.03.2038 9/20/11 0 0 ce J z O_ z w z 1— z O U z AIP NUMBER cn z w w 0 d D W W W 0 z U J Z W 0 Cn W 3 -53- 0058 -044 z 0 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2038 .‘ WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFEREP TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS 'B, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1-145 BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "a AND 9' REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JONTS. NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN NSTALLED. SHEET METAL HEAD FLASHING (E) SIDING SCALE: NTS E) BLDG. PAPER ENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JONT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPR!YFED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELPIDGE WAY SW SUITE 200 • SEATTLE, ti'A 98106 (206) 624 -2777 • FAX (206) 624 -2973 4220 REGISTERED —141111G1 1 .1 %1 /P!' > .( E EMf'E ,ETC r3- p u HNC-TON 0810.03.2038 9/20/11 0 0 ce J z O_ z w z 1— z O U z AIP NUMBER cn z w w 0 d D W W W 0 z U J Z W 0 Cn W 3 -53- 0058 -044 z 0 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2038 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC H WG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEIUNG ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR XX 0 !X /Y / // / / / / / //i DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION 1- EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX ABBR I><1 0 -> 04- DN UP VD RA/EA RG SA SA RA /EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEIUNG SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND %1 RECTANGULAR ELBOW WITH TURNING VANES SWITCH or OR O. THERMOSTAT EQUIP IDS EQUIPMENT LOCATION NG 171 • 0 D"4 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISIOF INSTALLED UNDER . DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 G08 "WG 7 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 90 337 G08 "WG 7 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2038 750 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEIUNG R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. bi> 039 THERMOSTAT HOURS OF OPERATION SET THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) ¢,. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM FEB 07 2012 SEPARATE D PERMIT APPROVAL ED REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS l Protee.Ioaal Limited LtabiitG Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA .•106 (206) 624 -2777 • FAX (200) 624-2973 THE GREENBUSCH GROUP, INC 6 0 640 *IMO t 51r 101 SEPAL° 161 00110 (206) 376- 0660 (206) 376 -041 FM 0810 03.2038 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3-53-0058-044 DATE 9116/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2038 BATI4 (E)EG ) BEDROOM (E)SG (E)RG G KITCHEN D INING ROOF ATTIC LIVING ROOM (E)SG MAIN FLOOR MECHANICAL PLAN STUDY (E)SG s- ( E VEIN r SCALE: 1 /4" = 1' -0" OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN MOD, INTERLOCK TO FURNACE POC (1 (E)RETURN FURNACE (E)SUPPLY OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE FURNACE IN ATTIC GAS METER (E)VEI SEE SHEETMETAL TRANSITION TO GRILLE NECK SIZE Ii (E)EXAUST 1 VENT I 4— Ill L u n IL L_ 10' MIN — (E)FURNACE 1 L_ L___�1 ATTIC MECHANICAL PLAN t SCALE: 1 /4" = 1' -0" DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE —1 r u J 1 J J DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51- 52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. b )..4;47 SEPARATE PERMIT AND APPROVAL REQUIRED FEB 07 2012 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Protedeional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 684 -2777 • FAX (206) 624 -207 THE GREENBUSCH GROUP, INC fee* 001..) mo Nur 1101204 511V LIZ 201 Win 0311 (106) 376 - 0660 (206) 376 -0641 FAX 0810.03.2038 0 0 ce 0 LU z O 0 Ca RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2038 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE IUMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES Q PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. a PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. tS TN ELECTRICAL LEGEND END SYMBOL DESCRIPTION SYMBOL DESCRIPTION LIGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2'C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON - FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR [23 ELECTRICAL METER 11MER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE IMTH UTIUTY. THERMOSTAT COUNG MOUNTED FIRE ALARM - VISUAL STROBE UGHT UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR MECHANICAL ! ELECTRICAL COORDIN ,AT ION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 15 16 N/A REMARKS MOTOR OPERATED DAMPER 24 X THERMOSTAT 24 X x X 1,2 1 REMARKS: 1 - VER FY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH DINING 5EDIROOM IX MAIN FLOOR PLAN L I`./ING f.00M \ 1/4" = 1' NORTH D DO37 FEB 07 2012 SEPARATE PERMIT AND APPROVAL REQUIRED ■ S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (208) 624 -2973 0810.03.2038 MPROVEMENTS KING COUNTY AIP NUMBER 5- 53- 0058-043 TUKWILA WASHINGTON DATE 9/8/11 ISSUED M_27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2038 FAMILY ROOM SITTING ROOM MATH KITCHEN SPECIAL NOTES: NOTES: L ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM 614ALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRNG ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PANT 15 PRESENT AT TH15 RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WNDOW TRIM PAINT. LAUNDRY ROOM MAIN FLOOR PLAN 0 1/4" = 1' GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF TI -#ESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT TIME COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. IIOMEOUNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETU,EEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING NSTALLATION PROCEDURE ON WNDOW FLASHING DETAILS SWEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCI-E5 ON ARCHITECTURAL DRAWNGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO NTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FNISHE5 ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EIO FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WNDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOUR. POWER MUST BE PR vIDED AT RESIDENCE BEFORE 5:00 AM. 4 AFTER 55.00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENNGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WNDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WNDOW COVERINGS MUST SE PROVIDED. LIvING ROOM DINING A. WEST ELEVATION Li fl r L FLAT ROOF, NO ATTIC ACCESS. NO INSULATION !' 1 REQUIRED CJ B. NORTH ELEVATION PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCI- IEDULE. DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. O DOOR SCHEDULE. O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. O DEMOLISH EXISTING WALL AS REQUIRED TO INSTALL MECHANICAL DUCTING. RE: MECH. INSTALL FRAMING AND WALL FINISH AS REQUIRED TO MATCH EXISTING. O INSTALL FIREPLACE VENT, COORDNATE EXACT LOCATION WITH HOMEOWNER OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR GAP IN OPEN POSITION. INSTALL PER 6 MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. 0 INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. • ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 1 _J r _____ 1 !1 11 LJ L- L- ATTIC PLAN 1/8" = 1' II J I ____J IJ n — 1 p,39 C. EAST ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION D. SOUTH ELEVATION LEGEND C ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW u GABLE END VENT BAFFLE RIDGE VENT BAFFLE FEB 07 2012 FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. :: MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL i AND WHOLE 1-OUSE VENT INSTALLATION. ,.. `,� REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION sD INSTALL BATTERY OPERATED SMOKE DETECTORS 1146:1 KITCI -EN EXHAUST BAFFLE GAS METER SOFFIT FOR MECHANICAL DUCTING • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4-000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED /0°;IHrfE T CLTT iREMPE STATE 0= HINGTON 0810.03.2039 9/20/11 O 0_ —J O z w z Z 0 0 z AIP NUMBER MPROVEMENTS 0 w 2 w w 0 Z U I— Z w w 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW FLOOR PLANS NOTES A1.0 0810.03.2039 WINDOW TYPES 1. SLIDER WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A FAMILY ROOM 1 3' -11" x 2-11" STAIN /PAINT 1/A2.0 B FAMILY ROOM 1 2' -11" x 2' -11" STAIN /PAINT 1/A2.0 C SITTING ROOM 1 3' -11" x 2' -10" STAIN /PAINT 2/A2.0 D BEDROOM 1 1 3' -10" x 2' -3" STAIN /PAINT 2/A2.0 E LIVING 1 3' -10" x 3' -10" STAIN /PAINT 1/A2.0 F DINING 1 3' -10" x 4-3" STAIN /PAINT 1 /A2.0 G DINING 1 3' -10 "x 4' -9" STAIN /PAINT 1 /A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T -III SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADI -ER•G MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) T -111 SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -111 SIDING WINDOW HEAD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -111 SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDNG AS REQ'D TO MANTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING WINDOW JAMB (E) GW6 (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP W/ BATT NSULATION (E) GUS WD JAMB LNNG SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERNG MEMBRANE (E) GWB WINDOW SILL T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" (E) U.V. SIDING CAREFULLY LIFT (E) UJALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT 10 MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GWB (E) WALL UNDERLATMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) UJALL UNDERLAYMENT AND NSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYNENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILNG FIN -- WINDOW HEAD LID WOOD TRIM IUD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) GWB I — 1 TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WNDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING WINDOW JAMB WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP <W BATT INSULATION 3/4" 3/4" WD. SILL - STAIN TO MATCH (E) CONTINUOUS SEALANT, TYP. (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" bix--0a7 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED x;,07 EMPE ATE Vii` GHING T 4)N 9/20/11 0810.03.2039 ;- Et 0 0 ce J Q z 0 I- Q w z F- z 0 U z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2039 DOOR TYPES O A FLUSH mu W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT B EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET /FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 DINING A 3' -0" x 6' -9" STAIN /STAIN HW -1/609 DK -4 (CAMELOT) LOCK -1 1/A2.1 1/A2.1 2 FAMILY ROOM A 2' -8" x 6' -8" STAIN /STAIN HW -1/609 DK -4 (CAMELOT) LOCK -1 3 SITTING ROOM A 2' -8" x 6' -8" STAIN /STAIN HW -1/609 DK -3 (JUPITER) LOCK -1 2/A2.1 4 DINING B 3' -0" x 6' -9" 1/A2.1 5 FAMILY ROOM B 2' -8" x 6' -8" 1/A2.1 6 SITTING ROOM B 2' -8" x 6' -8" 2/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. REMOVE (E) T -111 SIDING AS REQ'D FOR INSTALLATION OF POOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADI -ERNG MEMBRANE. TYP AT HEAD AND JAMB PRE- PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF- ADHERING MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY CUT BACK (E) T -III SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -111 SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPNG INSTALLATION CONTINUOUS WEATHER - STRIPPING JAMB BEYOND DOOR HEAD DOOR JAMB WOOD DOOR PER SCHEDULE DOOR 5HOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR SILL SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING NSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FRAMING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE T -111 SIDING - DOOR DETAIL SET 3 "= 1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADI- IERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERNG MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PANT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL CAP FLASHING UNDER SELF- ADI -IERNG MEMBRANE. PAINT COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING NSTALLATION CONTINUOUS WEAT IER- STRIPPING DOOR PER SCHEDULE CAREFULLY CUT BACK (E) WD. SIDNG TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLAWING (E) WOOD SIDING DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE (E) EXTERIOR SHEATHING CONTINUOUS l l �� SEALANT, TYP. \ EXISTING FRAMING II Evpvtiii SOLID WOOD TRIM p MIN. DOOR JAMB 514111 AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE DOOR SILL WOOD SIDING - DOOR DETAIL SET 3" = 11 — 0" 1 1 1 REVIEWED FOR CODE COMPLIANCE AP RC?e. /ED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 0 7 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ST ER1D ERIPD STATE 0= HINGTO 0810.03.2039 9/20/11 O 0 J z 0 I— z LLJ z F— z 0 U z AIP NUMBER MPROVEMENTS D ce w W W 0 z U F— Z 3 -53 -0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2039 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHNG. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T -111 SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE t FLASHING. REPLACE W/ NEW SIDING 4 PANT TO MATCH (E) SIDING PRE- PRIMED, GALV SWEET METAL FLASHING W/ FF. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED N THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKNG 2X2 CONTINUOUS BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 =1 -0 b 11,03/ REVIEWED FOR 0ODE COMPLIANCE APPROIED FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 STEID ;ft / /'1r L.OTT T E. 0 0810.03.2039 Er.'PEE FJHENGj 9/20/11 0 a_ J 0 z w Lu O r9 O I z Zw C!) 0 I' z <C z � J z oce O 0 < 0 -J z < w 0 (1) w MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW MISC. DETAILS A2.2 0810.03.2039 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDNG AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. 12" (E) SHEATHING — GUT SILL FLASHING 4 FOLD TI4ROUCsN RO. AS SHOWN. LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1" BEYOND R.O. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I" MN MEMBRANE FLASHING AT SILL ir 5 if' Zst BUTTERFLY GONER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND I-EAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 14A5 BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. B a ` O O e O O O O O O ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOUN ,>' OVER NAIL FLANGE, HEAD ONLY. WINDOW MEMBRANE INSTALLATION (E) SHEATHING REMOVED SCALE: NTS EDGE OF (E) SIDING, SHOUN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOUJN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 14A5 BEEN INSTALLED. WHERE RED IRED, TRIM (E) BLDG - APER AT HEAD TO - PARE FOR INSTA LATION OF HEAD FLA- NG AND WINDOW TR (FOLLOWI ' STEPS). HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW SING AS SHOUN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAR, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FADE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL SNT. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 14A5 BEEN INSTALLED. ALLOW 1/0" LEARANCE BETUEEN FL • ING AND BOT. EDGE •' (E) SIDING. OF (E) SIDING, SHOUN DIAGRAMAT !CALL Y. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. ATHEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS 10 WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: is MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD FLASHING. S: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT 51-101.1.14 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDNG (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/ &" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME.. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS Q I�- -639 REVIEWED FOR CODE COMPLIANCE FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRTDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2039 9/20/11 H ce O d J Z O F— Q z w z z 0 U C� Z AIP NUMBER MPROVEMENTS 0 cew w w 0 ce z H- Z W D 3 -53 -0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2039 f-- r \\\\N I 10 WOOD TRIM INSTALLATION INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: is MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1445 BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "a AND 9" REFER TO SHEET METAL HEAD FLASHING. S: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT 51-101.1.14 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. SHEET METAL HEAD FLASHING (E) SIDNG (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/ &" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME.. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP AT ALL 4 SIDES. WINDOW FLASHING INSTALLATION SCALE: NTS Q I�- -639 REVIEWED FOR CODE COMPLIANCE FEB 17 2012 City of Tukwila BUILDING DIVISION FEB 07 2012 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRTDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2039 9/20/11 H ce O d J Z O F— Q z w z z 0 U C� Z AIP NUMBER MPROVEMENTS 0 cew w w 0 ce z H- Z W D 3 -53 -0058 -044 z 0 z_ DATE 9/20/11 ISSUED BP M -27 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &SW WINDOW FLASHING DETAILS A2.3 0810.03.2039 ABBREVIATIONS LEGEND ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD cw DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HISS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF READ RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLAN AND DETAILS DRAWING INDEX GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL ABBR $G —X XXX + r + g1S] DN UP VD RA /EA RG SA SA -1*- 40-F— RA /EA SD O- 0 41- -1 yj EA DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIP ID# OR �. EQUIPMENT LOCATION 171 MOD NG NG 0 MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 <08"WG 7 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A — MOTOR OPERATED DAMPER 24 1 X X X 1,2 — THERMOSTAT 24 1 X X X 1 REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 90 337 <08"WG 7 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2039 1132 1 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCOND111ONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 3 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) IQ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/3 QF = 30 / (1 X 1 /3) = 90 CFM Dla - -03°� FEB 0'7 2012 SEPARATE PERMIT AND APPROVAL REQUIRED 1 EXPIRES: 9/08/2012 1 S.M. STEMPER ARCHITECTS A Professional L1mit.d Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 96106 (206) 624 -2777 • FAX (206) 624 -2973 THE GREENBUSCH GROUP, INC ► (9 661...) '. Aooumi wood & B 9P N= 1900 6t3 • s�8Ekr SUITE 201 SEA ML 9w 98119 (206) 376-06e9 Noe) 378 -0841 FAX 0810.03.2039 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 9116/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2039 PLEASE vERIFY WINDOW LOCATION FAMILY ROOM ESG� SITTINGS ROOM SEE j1 90 4, (E)SG REMOVE WALL & REINSTALL 7 "0 (E)SG 3 8 ROOM i GAS METER BATH EEG LAUNDRY ROOM W D KITCHEN F,<1 EEG DRYER VENT MAIN FLOOR MECHANICAL PLAN CEILING SCALE: 1 /4" = 1 '-0" POC (E)RETURN FURNACE (E)SUPPLY FLOOR RA OPENINGS OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN MOD, INTERLOCK TO FURNACE OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE LIVING ROOM (Elm DINING SAFETY GLAZING DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -52- 0403.8.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. BLOCK OFF RETURN AIR OPENING WITH SHEET METAL AS REQUIRED. PERA�� AND APPROVAL REQUIRED FEB 07 2012 EXPIRES: 9/08/2012 1t S.M. STEMPER ARCHITECTS a Protaeeianal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 824 -2777 • FAX (206) 624 -2972 THE GREENBUSCH GROUP, INC ......1•.) aoousnrx. ID a I OWlCAL o108>mtlla 1000 AIJO stAEEr LE 181 SEAM 1w 08110 (208) 376-0669 (208) 378 -0841 FAX 0810.03.2039 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058-044 TUKWILA WASHINGTON DATE 9/16/11 ISSUED BID PACKAGE M -27 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2039 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. 0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. LocATIoN ELECTRICAL LEGEND $Th80L DESCRIPTION $Y1w1 01- DESCRIPTION UGHTING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE 112 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. INDICATES ISOLATED GROUND. EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION a NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. THERMOSTAT COUNG MOUNTED FIRE ALARM - VISUAL STROBE LJGHT 0 UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR F.h_ SITT ,.,, F MECI-1ANICAL ! ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 N/A 15 16 N/A REMARKS MOTOR OPERATED DAMPER THERMOSTAT 24 1 X X X 1,2 24 X X X 1 REMARKS: 1 - VEt FY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH MAIN FLOOR PLAN 1/4" = 1" NORTH DINING H SAFETY :I-. LING bR�3 9 SEPARATE PERMIT AND APPROVAL REQUIRED FEB 07 2012 111 S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDUE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 RNSIN'S'S. INC MN SOWN 41110 OMR. MIMI MI TAM% WA 1111411111111111 MPH= OM in «r FAN OM NB OM 0810.03.2039 F- ct 0 11 Q 0 z w z KING COUNTY AIP NUMBER MPROVEMENTS 5-53- 0058-043 DATE 918/11 ISSUED M-27 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2039