HomeMy WebLinkAboutPermit D12-043 - APPOLLO HOLDINGS - PALLET RACKSAPOLLO HOLDINGS 3314 S 116 ST D12 -043 City ofii'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Project Name: APPOLLO HOLDINGS DEVELOPMENT PERMIT Permit Number: D12-043 Issue Date: 03/16/2012 Permit Expires On: 09/12/2012 Owner: Name: APOLLO HOLDINGS LLC Address: 505 5TH AVE S #900 , SEATTLE WA 98104 Contact Person: Name: JIM PAOLETTI Address: 3500 WEST VALLEY HY N, SUITE 101 , AUBURN WA 98001 Contractor: Name: RAYMOND HANDLING CONCEPTS Address: 4140 BOYCE RD , FREMONT CA 94538 Contractor License No: RAYMOHC034KB Lender: Name: Address: Phone: 253 - 929 -7570 Phone: 253 - 333 -2109 Expiration Date: 10/05/2013 DESCRIPTION OF WORK: INSTALL PALLET RACKING Value of Construction: $0.00 Type of Fire Protection: SPRINKLERS Type of Construction: Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: $243.92 International Building Code Edition: 2009 Occupancy per IBC: * *continued on next page ** doc: IBC -7/10 D12 -043 Printed: 03 -16 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: Private: Profit: N Private: N Public: Non - Profit: N Public: Date: ` W 0-■ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: ■ Y-„ � 'DUE-7 -1- Date: 3? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 D12 -043 Printed: 03 -16 -2012 6: All construction shall be done in conform - with the approved plans and the requirem of the International Building Code or International Residential C , International Mechanical Code, Washingt to Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Maintain fire extinguisher coverage throughout. 17: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 19: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 20: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D12-043 Printed: 03 -16 -2012 24: These plans were reviewed by Inspectc01. If you have any questions, please call Tule. Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -043 Printed: 03 -16 -2012 CITY OF TUK V iA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Per Project No. Date Application Accepted: Date Application Expires: 1r. No. b '04( 3 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3314 S 116th St Tukwila WA 98168 Tenant Name: Apollo Holdings PROPERTY OWNER Name: Jim Paoletti Name: Apinto ilow/ l/G5 LLC City: Auburn State: WA Zip: 98001 Address: g- SiA Ail{ �1Y, Email: jimp @raymondhandling.com City: RATTLE State: wit,. Zip: %Rif CONTACT PERSON — person receiving all project communication Name: Jim Paoletti Address: 3500 West Valley Hwy N suite 101 City: Auburn State: WA Zip: 98001 Phone: (253) 929 -7570 Fax: (253) 333 -5051 Email: jimp @raymondhandling.com GENERAL CONTRACTOR INFORMATION Company Name: Raymond Handling Concepts Address: 3500 West Valley HWY suite 101 City: Auburn State: WA Zip: 98001 Phone: (253) 333 -2100 Fax: (253) 333 -5051 Contr Reg No.: RAYMOHC034KB Exp Date: 10/05/2012 Tukwila Business License No.: 11 Wpplications\Forms- Applications On Line \2011 Apphcauons\Permu Application Revised - 8 -9 -11 dots Revised August 2011 bh King Co Assessor's Tax No.: 1023004 -9011 Suite Number: Floor: New Tenant: ❑ Yes ®..No ARCHITECT OF RECORD Name: Company Name: Structural Concepts Company Name: Engineer Name: Bob Sharifi Architect Name: City: Anaheim State: CA Address: Phone: (714) 632 -7330 Fax: (714) 632 -7763 City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Company Name: Structural Concepts City: State: Zip: Engineer Name: Bob Sharifi Address: 1200 N jefferson St City: Anaheim State: CA Zip: 92807 Phone: (714) 632 -7330 Fax: (714) 632 -7763 Email: bob @sceinc.net LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO 06- 431 -3670 Valuation of Project (contractor's bid price): $_ 2, S b Describe the scope of work (please provide detailed iniormatton): ?c,ac, C <- Existing Building Valuation: $ Will there be new rack storage? SAI Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: K. Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County l lealth Department. H'\Applications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -11 docx Revised- August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: K. Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County l lealth Department. H'\Applications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -11 docx Revised- August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES --- • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I I IEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR EIORIZED AGENT: Signature: Print Name: YA O(g'C`T' ‘) Date: 2— -1 a -12- Day Telephone: Z o (o ' 3 �1 1 -737 & Mailing Address: 3e-1500 W On _e ‘.),,1V! S »v:{c io t - Av. &)a-p.) VP 6a O 1 City State Zip 11 \Applications \Forms - Applications On Line\201 I ApplicationsWermit Application Revised - 8 -9 -11 docx Revised August 2011 bh Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.eov Parcel No.: 1023049011 Address: 3314 S 116 ST TUKW Suite No: Applicant: APPOLLO HOLDINGS RECEIPT Permit Number: D12-043 Status: PENDING Applied Date: 02/10/2012 Issue Date: Receipt No.: R12 -00603 Payment Amount: $243.92 Initials: WER Payment Date: 02/10/2012 04:12 PM User ID: 1655 Balance: $0.00 Payee: RAYMOND HANDLING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 068569 243.92 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $243.92 145.10 94.32 4.50 doc: Receiot -06 Printed: 02 -10 -2012 INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: V� 0 Type of Inspection: Address: %1 l C�' s tit/ cif. Date Called: Special Instructions: Date Wanted: 41._ *a1.. t C. rNt' p.m.' Requester: Phone No: pproved per applicable codes. ❑ Corrections required prior to approval. 1 COMMENTS: /-1-4N.01 Date: E SPECTION FEE REQUIR Prior jo next inspection. fee must be p d at 6300 Southcenter Blvd.. uite 100. Call to schedule reinspection. INSP TIO NO INSPECTION RECORD Retain a copy with permit Q. PERMIT NO. CITY OF TUKWILA BUILDING DIVISLO.N ----- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 —206) 431-367Q. Permit Inspection Request Line (206) 431 -2451 - Pr en- /(}itd Ai) (j�,1(� Type -litj 1njCkJ,,(40, 1 4� Address: .j~�+ 33/4 !1(a - Date Called: Special Instructions: re_ Ac c 1 /�`/t� /r�� J Y"C4 6e -n �i1A{ e. 'i ad J : A / Date Wanted: 3- ? (o - / a m p.m. Requester:J2" f l . 1''[ Phi.n d® -31 I _ 3 70 IDApproved per applicable codes. ElCorrections required prior,to approval. COMMENTS: old si o Lk__ Inspector: IDatef:?_ / , 12 C ? l.o REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 L »2 -c' y3 Project: 4 , « f /at> >A/6 S Type of Inspection: ...1•1L Address: Said ., /6 %%- Date Called: Special Instructions: Date Wanted:. �— 2Z- /,sm. a. Requester: Phone No: 0206 -3c•I -7376) 0 Approved per applicable codes. Corrections required prior to approval. S' COMMENTS: 04 Aep Datsi: REINSPECTIONE REQUIRED rior to next inspection, fee must be paid at 6300 So center Blvd.. uite 100. Call to schedule reinspection. L '77- / 11 7 ,,J INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Da -00/3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 *(L Project: A p c 1I a LA/Aael-v+�s� Type of Inspection: f�c r7:7,,, / Address: 3314 S ) 16. s r Suite #: Contact Person: /3:// Monitor: Special Instructions: Phone No.: 2 ' - 39/- 7370 `7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,G41 ..<3 Date: 3/ //2- Hrs.: r r!- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: 1 State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry A s p h a l t R o o f i n g P i l i n g S t e e l S o i l s W o o d March 27, 2012 File: 12 -219 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Apollo Warehouse Address: 3314 S. 116th St. Permit No.: D12 -043 A.A.R. TESTING LABORATORY, INC. CONS1RL. TION I. SPC 7TION AND MATER! 'L 1,ST INC I ,11ON..LLY ACCEPTED LAPORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. 6Cs, Kimberle Anderson President CC: Raymond Handling Concepts -Jim Tel: (425) 881 -5812 Fax: (425) 881 -5441 7126 180th Ave. NE 0 P.O. Box 2523 * Redmond, WA 98073 Client: Raymond Handling Concepts 3500 W. Valley Hwy. N, #101 Aubum, WA. 98001 Contact: Field Report Report #: 54477 Project Number: 12 -219 Permit #: D12 -043 Project Name: Apollo Warehouse Address: 3314 S. 116th St. Inspection Performed: Proprietary Anchors Date: 3/22/2012 Time: Temperature: Verified anchors to be Hilti KB -TZ 1/2" x 4 1/2" wedge type. Verified hole cleanliness and minimum embedment of 3 1/4". Torque was tested with calibrated wrench #132A and was found meeting the 40 ft./lb. requirement. All newly installed racking on sheet #1 was found in conformance with approved plans, manufacturers recommendations and ESR#1917. Distribution: Distribute Client ❑ Distribute Contractor ❑ Distribute Owner ® Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other ❑ Distribute Engineer Inspector: Chandler, Loren Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden ,._ St ctural L.Poncepts ngineering EVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2012 City of Tukwila BUILDING DIVISION ig 1200 N. Jefferson St, Suite F Anaheim, CA 92807 : 714.632.7330 Fax: 714.632.7763 e -mail: mail @sceinc.net Project Name : APOLLO WAREHOUSE Project Number : M- 020212 -7 Date : 02/06/12 Street Address : 3314166TH ST City /State : TUKWILA, WA 08168 Scope of Work : SELECTIVE RACK FEB o 22 RECEIVED FEB 10 2012 PERMIT CENTER Structural Concepts Engineenng 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632 7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads Column ..... 7 Beam and Connector Bracing 10 Anchors . 11 Base Plate 12 Slab on Grade 5 to 6 8to9 13 A!'r.?LLO WA,Ct'c>, :',E M 2.7 Page 2 of l 3 2/3/2()I? Structural Concepts ":" Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Design Data 1) The analyses conforms to the requirements of the 2009 IBC and the 2008 RMI /ANSI MH 16.1 Rack Design Manual Steel Storage Racks (RMI) and the ASCE 7 -05, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy =55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy =55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AVVS procedures, utilizing E7Oxx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The slab on grade is 5.5" thick with minimum 2500 psi compressive strength. Soil bearing capacity is 500 psf. Definition of Components Y y Frame Height d1 Beam A 1 Product Beam Spacing Beam Length Front View: Down Aisle (Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors Panel Height Frame od Depth Section A: Cross Aisle (Transverse) Frame Horizontal Brace Diagonal Brace AF'QLL Q WAR IO! 0- M 020? f 2 7 Page 3 of % 3 2 /3/2.01 2 Stryktural oncepts ®� Engineering 1200 N. Jefferson Ste._ Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Configuration & Summary: TYPE 1 SELECTIVE RACK 197' 44" --f * *RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 200 /b AXIAL LL= 3,000 /b SEISMIC A XI A L P S= +/- 2,137 lb BASE MOMENT= 0 in -/b Seismic Criteria # Bm Lvls 60" Frame Height # Diagonals 60" Frame Type Ss= 1.443, Fa =1 60" 44 in 4- 5 144 in 17' Fy =55 ksi --T Lu =144 in 144 44" --f * *RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 200 /b AXIAL LL= 3,000 /b SEISMIC A XI A L P S= +/- 2,137 lb BASE MOMENT= 0 in -/b Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss= 1.443, Fa =1 4 44 in 192.0 in 5 144 in Single Row Component Description STRESS Column Fy =55 ksi Hannibal IF3014- 3x3x14ga P =2400 Ib, M =3567 in -Ib 0.25 -OK Column & Backer None None None N/A Beam Fy =55 ksi HMH 55140/5.625" Face x 0.075° thk Lu =144 in Capadty: 6141 Ib /pr 0.24 -OK Beam Connector Fy =55 ksi Lvl 1: 3 pin OK I Mconn =2467 in-lb Mcap =12691 in-lb 0.19 -OK Brace - Horizontal Fy =55 ksi Hannibal 1 -1 /2x1- 1 /2x16ga 0.14 -OK Brace - Diagonal Fy =55 ksi Hannibal 1 -1 /2x1- 1 /2x16ga 0.17 -OK Base Plate Fy =36 ksi 8 in x 5 in x 0.375 in I Fixity= 0 in -Ib 0.61 -OK Anchor 2 per Base 0.5' x 3.25" Embed HILTI KWIKBOLT 17 ESR 1917 Inspection Reqd (Net Seismic Uplift =1338 Ib) 0.308 - OK Slab & Soil 5.5" thk x 2500 psi slab on grade. 500 psf Soil Bearing Pressure 0.45 -OK Level Load Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 1,500 Ib 12.0 in 42.0 in 21 Ib 7 Ib 3,200 Ib 1.103 "# 2.467 "# 3 oin OK 2 3 4 1,500 Ib 1,500 Ib 1,500 Ib 60.0 in 60.0 in 60.0 in 42.0 in 42.0 in 42.0 in 12.0 in 126 Ib 230 Ib 335 Ib 43 Ib 79 Ib 115 Ib 2,400 Ib 1,600 Ib 800 Ib 3,567 "# 2,919 "# 1,730 "# 3,148 "# 2,459 "# 1,364 "# 3 pin OK 3 pin OK 3 pin OK 1 712 Ib Total: 245 Ib Af'OL f 1) WA!2E11O[J3F -M 0202 1 2 -7 Page y of /3 2/3/201 2 Structural Concepts - ity-s/ Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Seismic Forces Configuration: TYPE 1 SELECTIVE RACK Lateral analysis is performed with regard to the 2009 IBC Sec. 2208.1, 2008 RMI/ANSI MH 16.1 Sec 2.6 & ASCE 7 -05 sec 15.53 Transverse (Cross Aisle) Seismic Load V= Cs *Ip *Ws =Cs *Ip *(0.67 *LL*PLrf +DL) Csl= [Sds /R] * 0.67 = 0.1611 Cs2= 0.044 *Sds *0.67 = 0.0284 Cs3= [0.5 *51 /R] * 0.67 = 0.0415 Cs -max= 0.1611 O ® factor per RPVtmww., Si Li& Sec 21 Line StatesRMrtln b.[s L,, j Base Shear Coeff =Cs= 0.1611 ASD Format Loads Level 1 2 3 4 PRODUC LOAD/LVL,PL 1,500 Ib 1,500 lb 1,500 Ib 1,500 Ib Cs -max * Ip= 0.1611 V,,;r,= 0.015 Eff Base Shear =Cs= 0.1611 Ws= (0.67 *Piar, * PL) +DL = 4,420 Ib PL *0.67 *PLrf 1,005 Ib 1,005 Ib 1,005 Ib 1,005 Ib Tran verse Elevation Vtransv =Vt= 0.1611 * (400 Ib + 4020 Ib) EL= 7121b ASD Level Transverse seismic shear per upright DL 100 Ib 100 lb 100 Ib 100 Ib hi 12 in 72 in 132 in 192 in wi *hi 13,260 79,560 145,860 212,160 Ss= 1.443 S1= 0.495 Fa= 1.000 Fv= 1.505 Sds= 2 /3 *Ss *Fa= 0.962 Sd1= 2 /3 *S1 *Fv= 0.497 Ca= 0.4 *2 /3 *Ss *Fa= 0.3848 (Transverse, Braced Frame Dir.) R= 4.0 Ip= 1.0 PLRF1= 1.0 Pallet Height =hp= 60.0 in DL per Beam Lvl= 100 Ib FI 20.9 lb 125.6 Ib 230.4 Ib 335.1 Ib Fi *(hi +hp /2) 878-11 12,811 -# 37,325 -# 74,392 -# sum: 6,000 Ib 4,020 Ib Longitudinal (Downaisle) Seismic Load ISimilarty for longitudmal seismic loads, using R =6.0 Cs1= 5d1 /(T*R)= 0.0555 Cs2= 0.0284 Cs3= 0.0276 Cs -max= 0.0555 Level PRODUC LOAD/LVL,PL 1 1,500 Ib 2 1,500 Ib 3 1,500 lb 4 1,500 Ib 400 Ib W =4420 lb 450,840 712 Ib 2= 125,406 Ws= (0.67 * PLRF2 * PL) + DL = 4,420 Ib Cs= Cs- max*Ip= 0.0555 PLRr2= (Longitudinal, Unbraced Dir.) R= 6.0 r= 1.00 sec Vlong= 0.0555 * (400 Ib + 4020 Ib) EL= 245 Ib ASD Level Long& seismic shear per upright PL *0.67 *PLrf 1,005 Ib 1,005 Ib 1,005 Ib 1,005 Ib DL 100 Ib 100 Ib 100 Ib 100 lb hi 12 in 72 in 132 in 192 in wi *hi 13,260 79,560 145,860 212,160 F 7.2 Ib 43.2 Ib 79.3 Ib 115.3 Ib Front View sum: 4,020 lb 400 lb W =4420 lb 450,840 245 Ib WAKFHCI!5l= M 0202 1 2. 7 Page of /3 ?/31201? Structural Concepts J ®--s Engineering � 1200 N. Jefferson Ste. Ste F Anaheim. CA 02807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Downaisle Seismic Loads Configuration: TYPE 1 SELECTIVE RACK Determine the story moments by applying portal analysis. The base plate is assumed to provide no fixity. Seismic Story Forces Vlong= 245 Ib Vco1= Vlong /2= 123 Ib F1= 71b F2= 43 Ib F3= 79 Ib Seismic Story Moments Typical frame made Tributary area of two columns of rack frame Frost View Conceptual System tit \..\ \J 2 Typical Frame made of two columns ailiilieilt Top View Mbase -max= 0 in -Ib c = == Default capacity Mbase -v= (Vcol *hleff) /2 = 551 in -Ib <_ == Moment going to base Mbase -eff= Minimum of Mbase -max and Mbase -v = 0 in -Ib PINNED BASE ASSUMED M 1 -1= [Vcol * hleff) -Mbase -eff M 2 -2= [Vcol- (F1) /21 * h2 = (123 Ib * 9 in) -0 in -Ib = [123 Ib - 21.6 Ib] *60 in /2 = 1,103 in -Ib = 3,567 in -Ib hl -eff= hi - beam clip height/2 = 9 in Vcol Mseis= (Mupper +Mlower) /2 Mseis(1 -1)= (1103 in -Ib + 3567 in -lb) /2 Mseis(2 -2)= (3567 in-Ib + 2919 in -Ib) /2 = 2,335 in -Ib = 3,243 in -Ib Beam to Column Eleva ion Summary of Forces LEVEL hi 1 12 in 2 60 in 3 60 in 4 60 in Axial Load 3,200 Ib 2,400 Ib 1,600 Ib 800 Ib Column Moment 1,103 in -Ib 3,567 in-Ib 2,919 in-Ib 1,730 in-Ib Mconn= (Mseismic + Mend -fixity) *0.75 Mconn- allow(3 Pin)= 12,691 in-Ib Mseismic Mend -fixity Mconn ** 2,335 in -Ib 954 in -Ib 2,467 in -Ib 3,243 in-Ib 954 in-Ib 3,148 in-Ib 2,324 in-Ib 954 in-Ib 2,459 in-Ib 865 in-Ib 954 in -Ib 1,364 in-Ib Beam Connector 3 pin OK 3 pin OK 3 pin OK 3 pin OK AFC)LLO) WAi ! 10U L M 0702 1 2 7 Page (.f' of 2/3/20 12 Structural Concepts - -®� Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Column (Longitudinal Loads) Configuration: TYPE 1 SELECTIVE RACK Conforms to the requirements of Chapter C5 of the AISI Cold Formed Steel Design Manual for combined bending and axial loads. Section Properties Section: Hannibal IF3014- 3x3x14ga Aeff = 0.643 in ^2 Ix = 1.130 in ^4 Sx = 0.753 in ^3 rx= 1.326 in S2f= 1.67 E= 29,500 ksi Loads Considers loads at level 2 Iy = 0.749 in ^4 Sy = 0.493 in ^3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 57.2 in Ky = 1.0 Ly = 42.0 in Cb= 1.0 3.000 in jy' - -v I _ 10.075 in 10.75 in 3.000 in COLUMN DL= 150 lb COLUMN PL= 2,250 Ib Mcol= 3,567 in -Ib 0.11Sds= 0.10582 0.14Sds= 0.13468 Axial Analysis Critical load case RMI Sec 2.1, item 4: (1 +0.11Sds)DL + (1 +0.145DS)PL *0.75+EL *0.75 <= 1.0, ASD Method Axial Load =P= (1.10582*150 Ib)+(1.13468*2250 ib *0.75) = 2,081 Ib Moment =Mx= Mcol *0.75 = 3567 in -Ib * 0.75 = 2,675 in -Ib Kxt x /rx = 1.7 *57.19"/1.326" KyLy /ry = 1 *42 "/1.08" =73.3 = 38.9 Fe= n ^2E /(KL/r)max ^2 = 54.2ksi Pn= Aeff*Fn = 26,386 Ib P /Pa= 0.15 > 0.15 Bending Analysis Fy /2= 27.5 ksi S c= 1.92 Fe > Fy /2 Fn= Fy(1- Fy /4Fe) = 55 ksi *[1 -55 ksi /(4 *54.2 ksi)] = 41.0 ksi Pa= Pn /S2c = 263861b/1.92 = 13,7431b Check: P /Pa + (Cmx *Mx) /(Max *px) 5 1.0 P /Pao + Mx /Max <_ 1.0 Pno= Ae *Fy = 0.643 in ^2 *55000 psi = 35,365 Ib Max= My /S2f = 41415 in -Ib /1.67 = 24,799 in -Ib px= {1 /[1 -(Qc *P /Pcr)] } ^ -1 = {1/[1- (1.92 *2081 lb /348071b)] } ^ -1 = 0.89 Combined Stresses Pao= Pno /Qc = 353651b/1.92 = 18,419 Ib Myield =My= Sx *Fy = 0.753 in ^3 * 55000 psi = 41,415 in -Ib Pcr= n^2EI /(KL)max ^2 = n ^2 *29500 ksi /(1.7 *57.19 in) ^2 = 34,807 Ib (2081 lb/13743 Ib) + (0.85 *2675 in- Ib)/(24799 in-Ib *0.89) = (2081 Ib/18419 Ib) + (2675 in- Ib/24799 in-Ib) = 0.25 < 1.0, OK (EQ C5 -1) 0.22 < 1.0, OK (EQ C5 -2) APOLLO WAKJ_`I ii)i 1`iE M -0202 12- 7 Page 7 of /3 2/3/20 2 Str tural once is Mngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. BEAM Project: APOLLO WAREHOUSE Project #: M- 020212-7 Configuration: TYPE 1 SELECTIVE RACK DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (B2.1) w= c - 2 *t -2 *r = 1.75 in - 2 *0.075 in - 2 *0.075 in = 1.450 in w /t= 19.33 1= lambda= [1.052/(k) ^0.5] * (w /t) * (Fy /E) ^0.5 = [1.052/(4) ^0.5] * 19.33 * (55/29500) ^0.5 = 0.439 < 0.673, Range is fully effective Eq. B2.1 -4 Eq. B2.1 -1 B) check web for local buckling per section b2.3 fl(comp)= Fy *(y3 /y2)= 50.69 ksi f2(tension)= Fy *(y1 /y2)= 102.45 ksi Y= f2 /f1 Eq. B2.3 -5 = -2.021 k= 4 + 2 *(1 -Y) ^3 + 2 *(1 -Y) Eq. B2.3 -4 = 65.18 flat depth =w= yl +y3 = 5.325 in w /t= 71 OK 1= lambda= [1.052/(k) ^0.5] * (w /t) * (fl /E) ^0.5 = [1.052/(65.18) ^0.5] * 5.325 * (50.69/29500) ^0.5 = 0.384 < 0.673 be =w= 5.325 in b2= be /2 Eq B2.3 -2 bl= be(3 -Y) = 2.66 in = 1.061 bl +b2= 3.721 in > 1.7625 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya= C *Fyc + (1 -C) *Fy (EQ A7.2 -1) Lcomer =Lc= (p /2) * (r + t/2) 0.177 in C= 2 *Lc /(Lf +2 *Lc) Lflange - top =Lf= 1.450 in = 0.196 in m= 0.192 *(Fu /Fy) - 0.068 (EQ A7.2 -4) depth = 0.1590 Bc= 3.69 *(Fu /Fy) - 0.819 *(Fu /Fy) ^2 - 1.79 (EQ A7.2 -3) = 1.427 since fu /Fv= 1.18 < 1.2 and r /t= 1 < 7 OK then Fyc= Bc * Fy /(R/t) ^m (EQ A7.2 -2) = 78.485 ksi Thus, Fya -top= 59.61 ksi (tension stress at top) Fya- bottom = Fya *Ycg /(depth -Ycg) = 115.71 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange-bot=Lfb= Lbottom - 2 *r * -2 *t = 2.450 in Cbottom =Cb= 2 *Lc /(Lfb +2 *Lc) = 0.126 Fy- bottom =Fyb= Cb *Fyc + (1- Cb) *Fyf = 57.97 ksi Fya= (Fya- top) *(Fyb /Fya- bottom) = 29.86 ksi if F= 0.95 Then F *Mn= F *Fya *Sx =i 46.98 in -k I 5.625 in 2.75 in t1.75 in Beam= HMH 55140/5.625" Face x 0.075" thk Ix= Sx= Ycg= t= Bend Radius =r= Fy =Fyv= Fu =Fuv= E= top flange =b= bottom flange= Web depth= 4.770 in ^4 1.656 in ^3 3.713 in 0.075 in 0.075 in 55.00 ksi 65.00 ksi 29500 ksi 1.750 in 2.750 in 5.625 in Fy yl= Ycg -t -r= 3.563 in y2= depth-Ycg= 1.913 in y3= y2 -t -r= 1.763 in Str tural once is � n 9 ineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S P Project: APOLLO WAREHOUSE Project #: M- 020212 -7 BEAM Configuration: TYPE 1 SELECTIVE RACK RMI Section 5.2, PT II Section Beam= HMH 55140/5.625" Face x 0.075" Nik Ix =Ib= 4.770 in/4 Sx= 1.656 in ^3 t= 0.075 in E= 29500 ksi Fy =Fyv= 55 ksi F= 150.0 Fu =Fuv= 65 ksi 1= 144 in Fya= 59.6 ksi Bending Mcenter =F*Mn= W *L *W *Rm /8 W =LRFD Load Factor= 1.2 *DL + 1.4 *PL +1.4 *(0.125) *PL RMI Z., item 5 FOR DL =2% of PL, W= 1.599 Rm= 1 - [(2 *F*L) /(6 *E *Ib + 3 *F*L)] 1 - (2 *150 *144 in) /[(6 *29500 ksi *4.77 in ^3) +(3 *150 *144 in)] = 0.952 if F= 0.95 Then F *Mn= F *Fya *Sx= 93.78 in -k Thus, allowable load per beam pair =W= F *Mn *8 *(# of beams) /(L *Rm *W) = 93.78 in -k * 8 * 2/(144in * 0.952 * 1.599) = 6,846 Ib/pair Mend= W *L *(1 -Rm) /8 = (6846 lb /2) * 144 in * (1- 0.952)/8 = 2,957 in-lb Deflection 5.625 in 2.75 in t1.75 in Dmax= Dss *Rd Rd= 1 - (4 *F*L) /(5 *F *L + 10 *E *Ib) = 1 - (4 *150 *144 in) /[(5 *150 *144 in) +(10 *29500 ksi *4.77 in ^4)] = 0.943 in if Dmax= L /180 and Dss= 5 *W *12^3 /(384 *E *Ib) L/180= 5 *W *L ^3 *Rd /(384 *E *Ib *# of beams) solving for W yields, W= 384 *E *I *2/(180 *5 *L ^2 *Rd) = 384 *4.77 in ^4 *2/[180 *5 *(144 in) ^2 *0.943) = 6,141 lb/pair Allowable Toad= 6,141 lb/pair 5 ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project N: M-020212-7 3 Pin Beam to Column Connection TYPE 1 SELECTIVE RACK The beam end moments shown herein show the result of the maximum induced fixed end monents form seismic + static loads and the code mandated minimum value of 1.5"/o(DL +PL) Mconn max= (Mseismic + Mend-fixity) *0.75 = 2,467 in-lb Load at level 1 Shear Capacity of Pin Connector Type= 3 Pin 2- Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)A2 * Pi /4 = 0.1507 inA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507inA2 = 3,315 lb Bearing Capacity of Pin tcol= 0.075 in Fu= 65,000 psi Omega= 2.22 a= 2.22 Pbearing= alpha * Fu * diam * tcol /Omega = 2.22 * 65000 psi * 0.438 in * 0.075 in/2.22 = 2,135 lb < 3315 Ib Moment Capacity of Bracket Edge Distance =E= 1.00 in Pin Spacing= 2.0 in C= P1 +P2 +P3 tclip= 0.18 in = P1 +P1 *(2.5 "/4.5 ") +P1 *(0.5 "/4.5 ") = 1.667 * P1 Mcap= Sclip * Fbending = 0.127 inA3 *0.66 *Fy = 4,610 in-lb Pclip= Mcap /(1.667 * d) = 4610.1 in-lb/(1.667 * 0.5 in) = 5,531 lb C *d= Mcap = 1.667 Thus, P1= 2,135 lb Mconn - allow= [P1 *4.5 " +P1 *(2.5 "/4.5 ") *2.5 " +P1 *(0.574.5 ") *0.51 = 2135 LB *[4.5 " +(2.5 "/4.5 ") *2.5 "+ (0.5 "/4.5 ") *0.51 = 12,691 in-lb > Mconn max, OK Fy= 55,000 psi Sclip= 0.127 inA3 d= E/2 = 0.50 in APUI_L( WARL:tilM >t -M 020212 7 Page of /3 4/3/2O ! 2 Structurai Concepts ngineering — _ 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Transverse Brace Configuration: TYPE 1 SELECTIVE RACK Section Properties Diagonal Member= Hannibal 1 -1 /2x1- 1 /2x16ga Horizontal Member= Hannibal 1 -1 /2x1- 1 /2x16ga Area= 0.273 in ^2 I _500 Area= 0.273 inA2 r min= 0.496 in r min= 0.496 in Fy= 55,000 psi r —� -- ,� Fy= 55,000 psi K= 1.0 I I I _500 K= 1.0 S2c= 1.92 ` _ _JI 0.25 Frame Dimensions 1.3-1.500 --el 14-0.25 I .500 Bottom Panel Height =H= 42.0 in Frame Depth=D= 44.0 in Column Width =B= 3.0 in Diagonal Member Clear Depth= D-B *2= 38.0 in X Brace= NO Critical load case RMI Sec 2.1, item 4: (1 +0.11Sds)DL + (1 +0.14SDS)PL *0.75 +EL *0.75 <= 1.0, ASD Method, DL =PL =0 for upright brace members D Vb= Vtransv= 712 Ib Ldiag= [(D- B *2)^2 + (H- 6 ") ^2] ^1/2 = 52.3 in Pmax= V *(Ldiag /D) * 0.75 = 635 Ib Pn= AREA *Fn = 0.273 in ^2 * 26208 psi = 7,155 Ib Pallow= Pn /Q = 7155 Ib /1.92 = 3,726 Ib Pn /Pallow= Horizontal brace 0.17 <= 1.0 OK (kI /r)= (k * Ldiag)/r min = (1 x 52.3 in /0.496 in ) = 105.4 in Fe= pi ^2 *E /(ki /r)^2 = 26,208 psi SINCE Fe<Fy /2, Fn= Fe = 26,208 psi 3" tYP B 4 Typical Panel Confiaurat on Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.060 in Weld Capacity= 0.75 * tmin * L * Fu /2.5 = 2,925 Ib OK Pmax =V= 534 Ib (kl /r)= (k * Lhoriz) /r min = (1x 44in)/0.496in = 88.7in SINCE Fe >Fy /2, Fn= Fy *(1- fy /4fe) = 34,564 psi Pn /Pallow= 0.14 <= 1.0 OK Fe= pi ^2 *E /(ki /r) ^2 Fy /2= 27,500 psi = 37,006 psi Pn= AREA *Fn = 0.273in ^2 *34564 psi = 9,436 Ib Pallow= Pn /Sk = 9436 Ib /1.92 = 4,915 Ib AI-1)LLL) WAk lit./J bE -M -0202 12 - / Pace / d of �j 43120 2 Structural Concepts rgr Engineering ® 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Single Row Frame Overturning Configuration: TYPE 1 SELECTIVE RACK Loads Load case per RMI Sec 2.1, item 3: (0.6- 0.11Sds)DL + (0.6- 0.14Sds)PLapp *0.75 - EL *0.75 Vtrans =V= 712 Ib DEAD LOAD PER UPRIGHT =DL= 400 Ib PL PER UPRIGHT =PL= 6,000 Ib PLapp =PL *0.67= 4,020 Ib Wst= (0.49418 *DL +0.46532 *PLapp *0.75)= 1,600 Ib PL @ TOP= 1,500 Ib DL/Lvl= 100 Ib E(R *hi)= 125,406 in -Ib Total Dead Load per Bay =DL= 400 Ib Load Case 1: Fully Loaded rack Vtrans= 712 Ib Movt= 1:(Fi *hi) *0.75 = 94,055 in -Ib (0.6- 0.11Sds)= 0.4942 (0.6-0.14Sds)= 0.4653 Frame Depth =D= 44.0 in Htop- lvl =H= 192.0 in # Levels= 4 # Anchors /Base= 2 h= 222.0 in hp= 60.0 in IfD� SIDE ELEVATION Load Case 2: Top Level Loaded Only c tical Level= 4 Mst= Wst * D/2 = 1600 1b * 44 in /2 = 35,200 in -Ib T= (Movt- Mst) /D = (94055 in -Ib - 35200 in- Ib) /44 in = 1,338 Ib Net Uplift per column h= 222.0 in V1 =Vtop= Cs * Ip * Ws Pinned Base Movt= [V1 *h + V2 * H /2J *0.75 = 0.1611 * (1500 Ib) _ [242 Ib *222 in +64 Ib*192 in /2] *0.75 = 242 Ib = 44,901 in -Ib V2=VDL= Cs *Ip *DL = 64 Ib T= (Movt- Mst) /D Mst= (0.49418 *DL +0.46532 *PL *0.75) * D/2 = (44901 in-Ib - 15865 in- Ib) /44 in = (100 Ib *4 * 0.49418 + 1500 Ib *0.46532 *0.75) *44 in /2 = 660 Ib = 15,865 in -Ib Net Uplift per column Anchor Check (2) 0.5" x 3.25" Embed HILTI KWIKBOLT TZ anchor(s) per base plate. Special inspection is required per ESR 1917. Fully Loaded: Top Level Loaded: Pullout Capacity=Tcap= 2,178 Ib L.A. City Jurisdiction? NO Shear Capacity=Vcap= 2,839 Ib Phi= 1 Tcap *Phi= 2,1781b Vcap *Phi= 2,839 Ib (669 Ib/21781b) ^1 + (178 Ib/2839 Ib) ^1 = (330 Ib/2178 Ib) ^1 + (61 Ib/2839 Ib) ^1 = 0.37 <= 1.2 OK 0.17 <= 1.2 OK AF'C L. WAk;rl f I I_ i`;; ?- M -r)Jn] 2 7 P icje / / of /3 2/3/20 ; , Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M- 020212 -7 Base Plate Configuration: TYPE 1 SELECTIVE RACK Section Baseplate= 8 in x 5 in x 0.375 in Eff Width =W = 8.00 in Eff Depth =D = 5.00 in Column Width=b = 3.00 in Column Depth=dc = 3.00 in L = 2.50 in Plate Thickness =t = 0.375 in Down Aisle Loads Critical load case RMI Sec 21, item 4: (1 +0.115ds)DL + (1 +0.145D5)PL *0.75 +EL *0.75 <= 1.0, ASD Method a = 3.00 in Anchor cc. =2 *a =d = 6.00 in N =# Anchor /Base= 2 Fy = 36,000 psi Downaisle Elevation COLUMN DL= 200 Ib COLUMN PL= 3,000 Ib Base Moment= 0 in -Ib 0.11Sds= 0.10582 0.14Sds= 0.13468 Axial =P= (1.10582'200 Ib) +(1.13468=3000 Ib *0.75) = 2,7741b Mb= Base Moment"' 0.75 = 0 in -Ib * 0.75 = 0 in -Ib I Axial Load P = 2,774 Ib Mbase =Mb = 0 in -Ib Axial stress =fa = P/A = P /(D *W) = 69 psi Moment Stress =fb = M/S = 6 *Mb /[(D *B ^21 = 0.0 psi Moment Stress =fbl = fb-fb2 = 0.0 psi M3 = (1/2) *fb2 *L *(2/3) *L = (1/3) *fb2 *L ^2 = 0 in -Ib S -plate = (1)(t ^2)/6 = 0.023 in ^3 /in fb /Fb = Mtotal/[(S-plate)(Fb)] 0.34 OK Tanchor = (Mb- (PLapp *0.75 *0.46)(a)) /[(d) *N /2] = -800 Ib No Tension Cabal bad case RHI Sec 2.4 dem 4: (1W.115ds)DL + (1+0.145.125"17.73+1317.75 c. 14 ASD Method Cross Aisle Loads M1= wL ^2/2= fa*LA2/2 = 217 in -Ib Moment Stress =fb2 = 2 * ft) * L/W = 0.0 psi M2= fb1 *L ^2)/2 = 0 in-Ib Mtotal = M1 +M2 +M3 = 217 in -Ib /in Fb = 0.75 *Fy = 27,000 psi Fp= 0.7 *Fc = 1,750 psi OK Tallow= 2,178 Ib Pstatic= 2,774 Ib Movt *0.75= 94,055 in-Ib Frame Depth= 44.0 in P= Pstatic +Pseismic= 4,912 Ib b = Column Depth= 3.00 in L =Base Plate Depth-Col Depth= 2.50 in fa = P/A = P /(D *W) = 123 psi Sbase /in = (1)(t ^2)/6 = 0.023 in ^3 /in fb /Fb = M /[(S- plate)(Fb)] 0.61 OK Pseismic= Movt/Frame Depth = 2,1381b M= wL ^2/2= fa *L ^2/2 = 384 in -ib /in Fbase = 0.75 *Fy = 27,000 psi APOLLO WAREHOUSE' M 0202 12 -7 Page 2 2_ of 0 OK Check uplift load on Baseplate Effec. Effec. 1 131 Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. When the base plate configuration consists of two anchor bolts located on either side the column and a net uplift force exists, the minimum base plate thickness all be determined based on a design bending moment in the plate equal the uplift force on one anchor times 1/2 the distance from e centerline of the anchor to the nearest edge of the rack column" T Ta Elevation Uplift per Column= 1,338 Ib Qty Anchor per BP= 2 Net Tension per anchor =Ta= 669 Ib c= 2.50 in Mu= Moment on Baseplate due to uplift= Ta *c /2 = 836 in -Ib Splate= 0.117 inA3 [fb /Fb] *0.75= 0.198 OK 2/3/20!2 Structural Concepts pi Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 921302 Tel: 714.632.7330 Fax: 714.632.7763 By: S.P. Project: APOLLO WAREHOUSE Project #: M -020212 -7 Slab on Grade Configuration: TYPE 1 SELECTIVE RACK 1111111111111111111111111111111111111111111111 Base Plate Effec. Baseplate width =B= 8.00 in Effec. Baseplate Depth =D= 5.00 in Column Loads width =a= 3.00 in depth =b= 3.00 in DEAD LOAD =DL= PRODUCT LOAD =PL= P- seismic =EL= Puncture 200 Ib per column unfactored ASD load 3,000 Ib per column unfactared ASO load (Movt/Frame depth) 2,137 Ib per column unfactored ASD load Basealate Plan View midway dist faze of column to edge of plate =c= midway dist face of column to edge of plate =e= Concrete fc= 2,500 psi tslab =t= 5.5 in teff= 5.5 in phi =0= 0.6 Soil fsoil= 500 psf Movt= 94,054 in -Ib Frame depth = 44.0 in Sds= 0.962 0.2 *Sds= 0.192 5.50 in 4.00 in Load Case 1) (1.2 +0.2Sds *DL) + (0.85 +0.2Sds *PL) + 1.5 *EL RMI SEC 2.2 EQTN 5 = 1.3924 *200 Ib + 1.0424 *3000 Ib + 1.5 *2137 Ib = 6,611 Ib Load Case 2) (0.9- 0.2Sds)DL + (0.9- 0.2Sds) *PLapp + 1.5EL RMI SEC 2.2 EQTN 6 = (0.7076 *200 Ib) + (0.7076 *2010 Ib) + (1.5 *2137 Ib) = 4,769 Ib Load Case 3) 1.2 *DL + 1.4 *PL RMI SEC 2.2 EQTN 2 = 1.2 *200 Ib + 1.4 *3000 Ib = 4,440 Ib Effective Column Load =Pu= 6,611 Ib per column Apunct= [(c +t) +(e +t)] *2 *t = 225.50 in ^2 Slab Bending Fpunct= 2.66 *phi *sgrt(fc) = 79.8 psi fv /Fv= Pu /(Apunct *Fpunct) = 0.367 < 1 OK Pse= DL +PL +E= 6,611 Ib AsoiI= (Pse *144) /( fsoil) = 1,904 in ^2 x= (L-y) /2 = 14.0 in Fb= 5 *(phi) *(fc) ^0.5 = 150. psi L= (Asoil) ^0.5 = 43.63 in M= w *x ^2/2 = (fsoil *x ^2)/(144 *2) = 338.9 in -Ib y= (c *e) ^0.5 + 2 *t = 15.7 in S -slab= 1 *teff ^2/6 = 5.041n^ 3 fb /Fb= M /(S- slab *Fb) = 0.448 < 1, OK AI'OLI_n WARLHO[Y M- ()2c0? 1 2 7 Page /3 of /3 2/3/2c) 1 2 • Raymond Handling Concepts Corporation 3500 W. Valley Hwy. North Telephone 253- 333 -2100 Suite 101 Telephone 888- 820 -8811 Auburn, WA 98001 Facsimile 253- 333 -5051 www.ravmondhandlina.com February 28, 2012 City of Tukwila PERMIT CENTER RE: Letter #2 Permit App: Apollo Warehouse Answers for questions on incomplete letter #2 1. Maximum Storage height of product 20 feet 2. Ceiling height is 28 feet 3. Material To be stored -Wood Crates Material will be stored directly wiredecks no solid shelving will be used. 4. There is sprinklers and density .395gpm Thank you Jim Paoletti Raymond Handling Concepts 206 - 391 -7370 R�Gtiv CITY QF TU LA MAR 012012 PERMIT CENTER INCOMPLETE LTR# 2- 0City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director February 22, 2012 Jim Paoletti 3500 West Valley Hy N, Suite 101 Auburn, WA 98001 RE: Incomplete Letter #2 Development Permit Application D12 -043 Apollo Holdings — 3314 S 116 St Dear Mr. Paoletti, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 16, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Fire Department: Al Metzler at 206 971 -8718 if you have questions concerning the following comments. 1) What is the maximum storage height to be from the floor to the top of the product? 2) What is the ceiling height? 3) What are the commodities to be stored? 4) What is the existing fire sprinkler density? Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, 4.--0 R.0‘.4.._ Bill Rambo Permit Technician Enclosures File: D12 -043 W:\Permit Center \Incomplete Letters\2012 \D12 -043 incomplete Ltr #2.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 CityfTukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director February 15, 2012 Jim Paoletti 3500 West Valley Hy N, Ste 101 Auburn, WA 98001 RE: Incomplete Letter #1 Development Permit Application D12 -043 Apollo Holdings — 3314 S 116 St Dear Mr. Paoletti, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 10, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, fer Ma shall 't Tech 1},ician Enc1Ds{ires File: D12 -043 W:\Permit Center \Incomplete Letters\2012\D12- 043 Incomplete Ltr 4 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 `, { Tukwila Building Division;" Allen Johanne'ssen, Plan Examiner Determination of Completeness Memo Date: February 14, 2012 Project Name: Apollo Holdings Permit #: D12 -043 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24)(36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a floor plan of the building that shows where and how many racks are to be installed. Provide dimensions of the building and specify square footage of the storage area. Show dimensions of the rack aisles and spacing. 2. Depending on the area size and occupant load, an egress plan may be required. Egress paths shall be identified and shall be provided with emergency illumination. Provide all applicable information on the plan for egress. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. `PERMIT COORD COW PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -043 PROJECT NAME: APOLLO HOLDINGS SITE ADDRESS: 3314 S 116 ST DATE: 03/01/12 Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 2 Revision # after Permit Issued DEPARTMENTS: AV` � � uilding Division ■ F e Prevention MI Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 03/06/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/03/12 Approved ❑ Approved with Conditions 1\4 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *EMIT COORD COFP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -043 PROJECT NAME: APOLLO HOLDINGS SITE ADDRESS: 3314 S 116 ST DATE: 02/16/12 Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n AVA Fire Prevention pm Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: DUE DATE: 02/21/12 Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/20/12 Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 ttF11Mi 4�JU1!�;1Wy • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -043 PROJECT NAME: APOLLO HOLDINGS SITE ADDRESS: 3314 S 116 ST X Original Plan Submittal Response to Correction Letter # Revision # DATE: 02 -10 -12 Response to Incomplete Letter # After Permit Issued DEP RTM NTS: °9-1111 ball Ing Ivlsion Public Works Fire Prevention Structural 1 Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -14 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: 07- 1C.11.— LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg X Fire ❑ Ping ❑ PW ❑ Staff Initials:_ TUES/THURS ROUTING: Please Route nStructural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 03-13-12 Approved Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DOCu nentshoufing slip_doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: -12- Plan Check/Permit Number: D12-043 • Response to Incomplete Letter # 2 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Apollo Holdings Project Address: 3314 S 116 St Contact Person: j Q p LE1 1, Phone Number: Rem NTV nF ALA MAR 0120121 t'ERMIT CENTER Summary of Revision: D f) trk,l td■ (�1 / croft) n1 S t.✓ <<S Lti 1 C L2 I Sheet Number(s): "Cloud" or highlight all areas of revision Intl ding date "of revision Received at the City of Tukwila Permit Center by: /0 O7jQt1tZ Entered in Permits Plus on \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D 12 -043 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued CITY NritiALA ❑ Revision requested by a City Building Inspector or Plans Examiner FEB 112012 PERMIT CENTER Project Name: Apollo Holdings Project Address: 3314 S 116 St Contact Person: St IM Po I✓ Phone Number: I 121 Q Summary of Revision: rev NLw - 014/44 ti ,r� wAs%ts an Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name RAYMOND HANDLING CONCEPTS CORP UBI No. 601785727 Phone 2533332100 Status Active Address 41400 Boyce Road License No. RAYMOHC034KB Suite /Apt. License Type Construction Contractor City Fremont Effective Date 5/2/1997 State CA Expiration Date 10/5/2013 Zip 94538 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date RAYMOND, STEPHEN 01/01/1980 KOEL, STEVE 01/01/1980 STERNBERG, PAUL 01/01/1980 GABORRO, ALEX 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 FEDERATED MUTUAL INS CO 1090263 07/22/2001 Until Cancelled $12,000.00 09/28/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 Federated Mutual Ins Co 9045549 10/01/1996 10/01/2012 $1,000,000.00 09/02/2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 03/16/2012 6" 222" / o 99 Li 'Coon Room 246" 296" SEPARATE PERMIT REQUIRED FOR: chanical Electrical Plurally Gas Pig City of Tukwila BUILDING DIVISION REVISNDNS No c afl es shams be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may include additional plan review fees. 1 44" 192" T.O.B. 132" .l 72" T.O.B. 12" T.O. Bo EN SPECIAL INSPECTION FOR STORAGE RACKS (OVER 8 FEET) Periodic special inspection is required during the anchorage of access floors and storage racks 8 feet or greater in height in structures assigned to Seismic Design Category D, E or F. IBC 1707.5 and TABLE 1704.4 (4) Inspection of anchors installed in hardened concrete. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2012 City of BUILDING • ISION 'Ia 44" FILE COPY Parmitt4o. 12 2--- `014( Pal revkos approvd Is oubliettoemcs and ontieet . mai of oonsbuction documents does not authc e It* violation of any adopted code or off. Receipt conditions is alm ed 01 City Of BUILDING DIVISION The P.E. certification provided herein by SCE, Inc. pertains to the storage rack components only. All other components are outside the seape ofthis certification. bixo 3 Engineer of Record Struc;u al Concepts Enginee °ir 1200 N. Jefferson St., ; t:. F .`ialy3i n (Th. (714) 632.7330 RECEIVE FEB 10 2012 PERMIT CENTER FEB 0 6 2:217, TO OUR CUSTOMERS: The information on this drawing is prepared with the intent of communicating a concept and design that is the intellectual property of Raymond Handling Concepts Corporation. It is not intended for other organizations as a means of quoting, designing /and or engineering alternatives. DESIGN BY: Raymond Handling Concepts Corporation For assistance call: 800.675.2500 DESIGN FOR: APOLLO SE DRAWING NO. SCALE 1/4 " =1'0" DRAWN BY S.L. PROJECT 9298 NUMBER SHEET OF DATE 10/05/11 CHECKED FILE NAME 9298vu1 REV. 3" 3" COLUMN NOTES: USE @ ALL COLUMN /BASE LOCATIONS TYP. 8" t DESCRIPTION BASE PLATE: 8" x 5" DESCRIPTION COLUMN: HMH IF 3014 DESCRIPTION BRACING: HORIZ. & DIAG. MATERIAL 3/8" THICK PLATE MATERIAL 14 GAGE THK. MATERIAL 16 GAGE STEEL STEEL YIELD ASTM A36, Fy= 36,000 PSI STEEL YIELD ASTM A570, Fy= 55,000 PSI STEEL YIELD ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL BRACE LOCATIONS TYP. HORIZ. BRACE GENERAL INFORMATION ROW SPACER OLUMN BEAM CONNECTOR BASE PLATE NOT A DEPICTION OF THIS PROJECT t-1 11/16" 5116E SAPEIY PIN NOTES: USE @ ALL HMH BEAM TO COLUMN CONNECTOR LOCATIONS. DESCRIPTION MATERIAL STEEL YIELD 3 -PIN CONNECTOR 7 GAGE ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL CONNECTOR TO COLUMN LOCATIONS TYP. DESCRIPTION 5 -5/8" BEAM (HMH# 55140) MATERIAL 14 GAGE STEEL YIELD ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL HMH BEAM LOCATIONS TYP. TYPE 1 SELECTIVE RACK 144" 192" 12" 11 44" FRONT VIEW REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2012 City of Tukwila BUILDING DIVISION GENERAL PROJECT NOTES 1. DESIGNED PER REQUIREMENTS OF THE 2009 IBC, 2008 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss = 1.443, 81 = 0.495, Fa = 1.00, Fv = 1.505 Ip = 1.0 (NO PUBLIC ACCESS), Sds = 0.962, Sd1 = 0.497, OCCUPANCY CATAG. II SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: 1500# PER LEVEL TYP. 4. ANCHORS HILTI KWIK BOLT TZ ICC /ESR# 1917, 1/2 "l X 3 -1/4" MIN. EMBED. (2) ANCHOR PER BASEPLATE 5. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR ANCHORAGE OF STORAGE RACKS 8 FEET OR GREATER IN HEIGHT IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 5.5" x 2500 PSI 7. SOIL BEARING PRESSURE 500 PSF 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER, INSTALL TO SNUG TIGHT FIT OR BETTER 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. bIOLf 3 ...BASE PLATE Engineer of Record Strii haral Concepts Engin eri n 1200 N. Jefferson S4: , ' x: Anah im, (714) 632. 330 F.F. 31 /4" MIN. EMBED. NOTES: /1/2" CONFIRM O.A.L. OF ANCHORS WITH INSTALLER TO ENSURE REQUIRED EMBEDMENT IS OBTAINED. RECEIVED FEB 10 2012 PERMITCENTER \ 4.. 3 ''1Q9 G SSE ;I • L NA, L ant FEB 0 6 X111 DESCRIPTION HILTI KWIK BOLT TZ ANCHOR SIZE 1/2 "0 X 3 -1/4" MIN. EMBED. DESCRIPTION STORAGE RACK ELEVATIONS ES R# 1917 NOTES: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. SHEET NO. SCE 1 OF 1