Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-060 - DANG RESIDENCE - GARAGE
DANG GARAGE 4208 S 124 ST D12 -060 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179000105 Address: 4208 S 124 ST TUKW Suite No: Project Name: DANG GARAGE DEVELOPMENT PERMIT Permit Number: D12-060 Issue Date: 03/07/2012 Permit Expires On: 09/03/2012 Owner: Name: FEDERAL NATIONAL MORTGAGE A Address: 8100 NATIONS WAY , JACKSONVILLE FL 32256 Contact Person: Name: THY DANG Address: 13744 45 AV S , TUKWILA WA 98168 Phone: 206 272 -0526 Contractor: Name: OWNER AFFIDAVIT - THANH DANG Phone: Address: Contractor License No: Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CONSTRUCTION OF 1100 SF DETACHED GARAGE. PUBLIC WORKS ACTIVITIES INCLUDE NEW ASPHALT DRIVEWAY, EROSION CONTROL AND STORM DRAINAGE. Value of Construction: $46,761.00 Fees Collected: $1,866.04 Type of Fire Protection: UNKNOWN International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 26 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -060 Printed: 03 -07 -2012 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: Y Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Y Water Main Extension: Water Meter: N Permit Center Authorized Signature: Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: /uH DA-/v Date: 3.7 -i2. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. doc: IBC -7/10 D12 -060 Printed: 03 -07 -2012 7: There shall be no occupancy of a buildinetil final inspection has been completed and roved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 15: Minimum 24 hours in advance contractor shall call Public Works at (206)433 -0179 to schedule a mandatory pre- construction meeting with Public Works Project Inspector, Mr. Dave Stuckle. The applicant must notify the City Project Inspector at (206)433 -0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 16: Contractor shall notify Public Works Project Inspector at (206)433 -0179 of commencement and completion of work at least 24 hours in advance. 17: Work affecting traffic flows shall be closely coordinated with the City Project Inspector. Traffic Control Plans shall be submitted to the Inspector for prior approval. 18: The City of Tukwila has an undergrounding ordinance requiring the power, telecommunications, and cable service lines be underground from the point of connection on the pole to the house. 19: Any material spilled onto any street shall be cleaned up immediately. 20: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 21: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. 22: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1 V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 23: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 24: It is strongly recommended that storm drainage designs be certified by a licensed engineer. Otherwise, the owner assumes liability for the design and any subsequent related damages. 25: Driveways shall comply with City residential standards. Driveway width shall be a 10' minimum and 20' maximum. Slope shall be a maximum of 15 %. Turning radii shall be a minimum of 5'. 26: The driveway shall be designed and sloped so that drainage from the driveway does not flow onto the existing road surface. 27: Driveways shall be paved for a minimum distance of 20' from the edge of the existing road pavement. doc: IBC -7/10 D12 -060 Printed: 03 -07 -2012 CITY OF TUKW Community Developn . < Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Suite Number: 1.1'\00 Site Address: 4'2. Og S. 12M +e1 S TEA i (A Wk gs' I (oS' Floor: Tenant Name: D Cu A ckJ i, \-0V1 Oarck New Tenant: ❑ Yes Al.. No Name: T't-A N t-I n�r�1G Address: /' 2OC, S 24 st City. Ti KtvI L State: Vc%4- Zip: 9 ? i6g1 Name: 744 ijl rti N G Address: 5% 4 Lt. 451..E ti L . City: -r.(.1 kw i State: j_ett Zip: erg I Ly Phone() 2.7 2 - 0S-.210 Fax: Email: .G). c.IG►t } /full n.t,i(a H:1ApplicationsTorms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: Page 1 of 4 U)<l I I tit W { '1II0kt' 20 =4:0 70 Valuation f Project (icpptractor's bid p : $ 0-01) Describe th seope•'of work (please provide detailed information): (rya e -e r . ExistingWilding Valuation: $ $1.e -e-1 bUl I al)13 Will there be new rack storage? ❑ .... Yes [..No If yes, a separate permit and plan submittal will be required. a t r ; f ; ,� � '•_���Wi`k''.1,,.:•. - a ^.::1�3• A< ' r � N 1':. t �� :' '' :',:s:,= �..,r Existing . `� xr , f� ut ;> _ xl, "� �y •- n .. Interiors emodel ., Additton to ' Existing ' , �i: , Structure ;,— , ` G u z ` 1 t,r a ,,New; t, • Type of Construction per r. 4s t, ; . , BC - . ,� xT yP 415P-:, Occupancy Perk } ' ...;;, IBC�a_ i :,.:ti i," Floor w iy, (101 . .: 2FIDOr "3rd Floor a ?'' I ;.j J 1 Rl ti'.le_ ... Floors." 1 athru n t> Basement . _ C+ p �, Y t 0 Accesso. , Strlictut'e' Attached Garage ` z 4s 'tii 1 { 7Y t iy T -. �n 3 Y Detached Garage 1 „; D�y 1/ 'Attached Car ort "� t ` *Detached Carport yr i Covered Deck ' , 1t t;- - , i- IttteOVered Deck 2s f7 %i PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm \JK None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line\20t 1 Applications\Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value f construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: L2/22/ I( Print Name: %(/A-/\/- I PA A/G7 Day Telephone: 62-06 ) 4 2 0 • -Z8 Mailing Address: /374 4 2/S tk A (A—; S . / U Ktti: (A s'1 c H:\Applications\Forms- Applications On Line\2011 Applicationaermit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh City State Zip Page 4 of 4 k Scope of Work (please provide detailed information): Call before you Dig: 811 • Please. refe'r:to Public Works Bulletin' #1` for fees'and'estimatesheet; Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Septic System: ❑ On -site Septic System — For on-sit • eptic system, provide 2 copies of a current septic design app . ed by King County Health Department. 0... Highline ...Valley View 0... Renton .- .Sewer Availability Provided ❑ .. Renton ❑..Seattl Submitted with Application (mark boxe hich apply): ❑ .. Civil Plans (Maximum Paper Size — 2 x 34 ") ❑ .. Technical Information Report (Storm Dr. ge) 0... Geotechnical Re ❑ ...Traffic Impact Analysis ❑ .. Bond 0... Insurance ■ Easement(s) 0... Maintenance eement(s) ❑ ...Hold Harmless -- (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hour ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0... Righ . f- -way Use - Profit for less than 72 hours 0... Ri -of -way Use — Potential Disturbance ... Work in Flood Zone 0... Storm Drainage ❑... Abandon ; .tic ❑... Curb C ❑... Pave . 'nt Cut ❑... Lo..; -d Fire Line ❑ .. Permanent Water Meter Size ... WO # ❑ .. Temporary Water Meter Size .. WO # ❑ .. Water Only Meter Size 7 7 WO # ❑ ...:;; duct Water Meter Size ❑ .. Sewer Main Extension Pu ' is ❑ Private ❑ ❑ .. Water Main Extension P ..lic ❑ Private ❑ 0... Grease Interceptor ❑ ... Channelization ❑...Trench Excavation 0... Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ , Sewer ❑ .. Sewage Treatment Monthly Service Billing to Name: Mailing Address: Water Meter Refun. : i11in : Day Telephone: Name: City State Zip Day Telephone: Mailing Address: City State Zip H:Wpplications\Forms- Applications On Line 1201 1 AppbcationslPermit Application Revised - 8 -9 -1 l.docx Revised: August 2011 bh Page 3 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179000105 Address: 4208 S 124 ST TUKW Suite No: Applicant: DANG GARAGE RECEIPT Permit Number: D12-060 Status: APPROVED Applied Date: 02/23/2012 Issue Date: Receipt No.: R12 -00963 Payment Amount: $1,272.95 Initials: VIER Payment Date: 03/07/2012 03:30 PM User ID: 1655 Balance: $0.00 Payee: THANK DANG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 71709A ACCOUNT ITEM LIST: Description 1,272.95 Account Code Current Pmts BUILDING - RES PW BASE APPLICATION FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW STATE BUILDING SURCHARGE 000.322.100 000.322.100 000.342.400 000.345.830 640.237.114 Total: $1,272.95 912.45 250.00 53.00 53.00 4.50 doc: Receiot -06 Printed: 03 -07 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0179000105 Address: 4208 S 124 ST TUKW Suite No: Applicant: DANG GARAGE RECEIPT Permit Number: D12-060 Status: PENDING Applied Date: 02/23/2012 Issue Date: Receipt No.: R12 -00774 Initials: User ID: JEM 1165 Payment Amount: $593.09 Payment Date: 02/23/2012 03:52 PM Balance: $916.95 Payee: THYDAO DANG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05518B ACCOUNT ITEM LIST: Description 593.09 Account Code Current Pmts PLAN CHECK - RES 000.345.830 593.09 Total: $593.09 doc: Receipt -06 Printed: 02 -23 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 w. (206) 431 -3670' Permit Inspection Request Line (206) 431 -2451 Project: RIJC,, CAR A( Type of Inspection: F )u..)AL • : Address: Lf 2 0 Q S 1 2 LI '51--- i Date Called: Special Instructions: Date Wanted:. I t - 2 1- 1'Z. � i% Requester: Phone No: ._C) re -27-2 • . Approved per applicable codes. El Corrections required prior to approval. COMMENTS: I 'spector: Date: / / / - 2 /--I ? . n EI�SPECTION FEE REQUIRE c . Prior to next inspection. fee must be day at 6300 Southcenter Blvd.. ' uite 100. Call to schedule reinspectionrr. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D11-00 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 � (206) 431 -36 0 Permit Inspection Request Line (206) 431 -2451 • Project: 0 6, (04 /A iP Type f C Inspection: .8 4 ;4 r Address: `7 Date Called: c_AJA Special Instructions: 1--e Date Wanted:. ( '( :m. r .m. Requester: Phone No: 7 2:7 z- - ®s 17 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (ii kl D `T—1 S el,c1J t e, .) TS'` L UJ arG3 -Asp e- i!i. f 1—i1,■/— L.. X A r.14 c_AJA ,,,..-11, --1::V- (0 A C ttf ..O ;. - 1--e J Ql; e_- Lo a i c--r , 1Inspor: 4 t Date: 1 C r. j REINSPECTION FEE REQUIRED. Prio ?.to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection; • el INSPECTION RECORD i `Retain a copy with permit • • INSPECTION NO. PERMIT NO. • CITY OF'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd:,- #100, Tukwila. WA 98188 11E. (206) 431 -3670 • .....Permit Inspection,Request Line (206) 431 -2451 0/2 -06 0 Project: bRA1G 6 ',1 Type of Inspection: `„� fd,aMiiN6 k O1 ( i A� Address: .41206 .5-' /1•y s ' Date Called: Special Instructions: • • . Date Wanted:. /O_2 _/Z 62m:. p.m. Requester: Phone No: ZoG - 2.72 -O'er( ,Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspect r. • Date:� REINSPECTION FEE REQUIRED.Piior to next inspection. fee must be . paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 11--®(av Project: Typer Inspection: f AAA4Af✓► OM iti L14(6J A ( t fje CpAJA-6,, Ad ess: '�1 Date Called: A t,J .H to di S GaJ v`Ff (--1A AA, Special Instructions: Date Wanted: S" - ((P - rZ -am.. p.m. Requester: Phone Noe 1 ,zq 2_ _ os ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: OM iti L14(6J A ( I VK.- 1 ; v i ( ( & l A t,J .H to di S GaJ v`Ff (--1A AA, ./\Sppf<.} !an vtr I il›DIn Ate Inspvor: Date: ...I REINSPECTION FEE REQUIRE. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ALWS INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 �, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 c Pro jest: 0 kc Ok e s of ; t-e J I\ 1-- -OPi, �: x� Type Inspection: • ' c nar 1L.: (A .021 (9/\ s. RE A,. j A Z Addre 4 or e eT p Date Called: () oI iss`Te. 1-0,A f; r :'11 fle Plp -eJ1l),J — or; lU•. "c'' airoei 11/\ Re' r6Af. YJI ( i "Z.1 - S ~1 — Special Instructions: Date Wanted: . ( L (r,.. Requester: Pho a No: {- ' riApproved per applicable codes. Corrections required prior to approval. ' COMMENTS: 0 kc Ok e s of ; t-e J I\ 1-- -OPi, �: x� 4 Dr'. + kA 7-0 i ,o n -el oe n1 j *`"'eve c nar 1L.: (A .021 (9/\ s. RE A,. j A Z `-- croft Acito s e eT p �p� oK -t-t) t-' -lb et � a te S , � P 04.1 () oI iss`Te. 1-0,A f; r :'11 fle Plp -eJ1l),J — or; lU•. "c'' airoei 11/\ Re' r6Af. YJI ( 1 a Inspe tor: Nek9L Date: • 3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must.be • paid at 6300 Southcenter Blvd.. Suite 100. Call to scheduie reinspection. • • • • • • • • • • • • • "r INSPECTION RECORD Retain a copy with permit t) 2" ��� INSP c I@ NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ja. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: f r‘ �� Type of Inspection:, f-TAAA,A6 • Date Called: Address: F (24 1 ( Special Instructions: co" ne p (1 1 0 (J7y Date Wanted: . C� -%L.---___m; p.m. Requester: Phone - 2-'7Z —IDS 2 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r‘ s -ste. x << r Qe e_m �ee co" lDeA0 - aP -6cri( For co" ne p (1 1 0 (J7y d ,5t' Q-e -scJ.e t' iAJ '^ Ale-il, Date: k 2- _72_ ❑ REINSPECTION FEE RE UIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 66t INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pr ect: w& & 6AtA6E Type of pecnQ��, _ 6 IA Addre W D / 24s`t- Date Called: Special Instructions: Date Wanted: I 8-., Z^ a.m. co s Requester: Phone No: rte, "� �/0 K/— 2: `�- -0S-2,/ Approved per applicable codes. Corrections required prior to approval. /‘ COMMENTS: P AV O .v ova J l/J1 t( ee `rte 'pri : 4 0 W M 'tom ,1k Sep AS Rre a e cx r 6 4 leer" r (JM f u lr A r-oitik lei j2 o z al 1t, iv ' i `i & i As-7 "44(PI (V\ W n .) kE c l - Muff-- J 2 5 I l la A-14 , AA (..i a r /3 lid, t � `( of\ -r-.5:__L .e.,A4Ltt. f , Misr- L.J.1 Ski Mvs ' cA eh J -ro ri REINSPECTION FEE REQUI ° ED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1:- • INSP.ECTIOMNO. INSPECTION RECORD Retain a copy with permit of -h0(1? PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,� (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ' •• Pro. 4. Qf �ClV ?4�,pP�� `W Type of Inspection: �j-` / �� VG't �:7 ....r\ a� ` ` Acid re 5. 5r Date Called: Special Instructions: • • Date Wanted:. 5r` -'17- � a.m. p.m. Requester: r Phone No: S e. J: 1_E ,..c P qa; r 1j-P IjApproved per applicable codes. Corrections required prior to approval. Z COMMENTS: (t ) SO; iD n6 tj- Ivi'ke. C LS (o;nM .. 'i r :rP ;'- (Al.M _Sr arJe.i b rA.D tr _ l 'i nJ e S r , ©R.._ T.,) Dr isitiN rf GO- h i v e . 0 nkq 0ir .i) k LAM J(1TO ASr[rJ c 60&.r t 4E, kA)M ( 14 !1 44-0 os E.- A4� ArGexf -r k:4, S e. J: 1_E ,..c P qa; r 1j-P �r 't ftr. � 1lnsptF' Date: 4, —7 Z_ ri REINSPECTION FEE REQUIRED D, Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. O INSPECTION NO. INSPECTION RECORD , Retain a copy with permit Ia1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro'ec Q:a Type of Inspection: - Address: W 9/910e. S /ay .; - Date C�1Ied: 8 1(1i, Special Instructions: - ,30 /at 11 Date Wanted: - ii 11141/d- a,m, T.• Requester: Phone No: ElApproved per applicable codes. 1i'') COMMENTS: ElCorrections required prior to approval. Ca.) -- Firy t -c(- - Fi✓ra.(ca( Inspector: Date: I f it� ltd REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule.reinspection. F • • • • • • • Li'• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1:::pwoig oject: Type of Inspect • Ad r Date Called: Special Instructions: - Date Wanted: .1 a m "� Requester: :rotor. Ply 6111A, ri , A• ;1 5 . VI1,+U (-cal Phone Approved per applicable codes. D Corrections required prior to approval. COMMENTS: `O c • '� _ ''D ien Ara ;" n system rNS`f-a ((ed De r a tQue (0-AS, 3)rSDerS(On +re/ane. tAtJr,t(+ 01 On • iio 41ik #Ao ,oc.A4fr 6111A, ri , A• ;1 5 . VI1,+U (-cal .r • v vo• iC - v In3pector. `O c • (Date: (O 13117— REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 50 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Probecct: 1 �. fY 2z r<rc. Type of Inspection: 1) Address: l� . 9An g !a V ,S-t- Date Called: 0-7.1 i 11 D. Special Instructions: Date Wanted:. Q7 //s II; G P.m. Requester • at 'VI- er la r -k ri15Oe c-t or) . Phone No ElApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: 'lee) -to 11-4 - re-reA - ) w,fkl 4i W1�r- Akbr; c_ A Ito( -Cif l 1,0i4 44 ru In roc-L- er la r -k ri15Oe c-t or) . Inspector: DS 'Date: f/( Irt n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •tRMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -060 PROJECT NAME: DANG GARAGE SITE ADDRESS: 4208 S 124 ST DATE: 02/23/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: m / W(, 2�—t)■ Ally- 03 -v(i® Building Division MP Fire Prevention Planning Division �� n / V� v —I/1 'P"ublic Works\ Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 02/28/12 Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 03/27/12 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplanPci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ss. T-074-N D7/ [please print name] , states as follows: PERMIT NO: D I )— (PV 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number /3 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. foe . onl"► s 01 A40 yW 40 80° {{ 1WAS" ".• Owner /Owner's Agent* Signed and sworn to before `me this f 1 day of / rdt_ aJ, 201 . OT ' Y PUBLIC in and for the State of Washington Residing at Name as commissioned: My commission expires: '770, , County 0� a� -/(J 18.27.090 Exemptions. The regiSion provisions of this chapter do not apply to• 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 KW... that employs a certified journeyman electrician, a cg ed reidgilti�l.,specialty electrician, or an electrica �a,,,1 e� 14 g titg'th14e requirements of chapter�t0t2$'RCW .to petrO ,plumbing work that is incidentally,; dire l y,.and immediately appropriate to the like4-k1 replacement offa household appliance or other small household utilization:equipment that requires limited eleZttic :power'and�limitcltwaste and /or water connections, electrical trainee-nust be supervised by a certified er °wiejitr while';pei4ptming plumbing work. `F3� �' ' • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. Thcsc plans have been review v the Pub 1,); "orl;s Department for conformance \vidi current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the acic` quac 0 .� . .. designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field inspection by the Public Works utilities inspector. Date: By' 3 06 i2 PLAWNIN0 APPROVED • No dwipN am be nwMb ANN plane without approval from the Plenninp Ohdeion of DCD 1'14 FILE COPY Pl^� —*ow approval Is abject to enure and omissions. ,21 of construction downs* does not authorize � . any adopted code or ordinance. Receipt h; Ueor ` Field and conditions : Copy at�ac�owte��i By f ` Date: , 3 - `7 Tirkwila BUILDING DIVISION /-20 TV K c 1r .) LA Ttf Si REVISIONS No changes shall be made to the of work without prior approval of Tukwila Building Division. will rzduire a new plan su • it +�l additional plan review fz 4 EPARATE PERMIT REQUIRED FOR: agethenicel C9 iectric si rO1 Ing s Piping Tukwila DIVISION al d31N3O JJV*33d m m N N N 1.xt Orn rr gcri REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2012� /� City of Tukwila BUILDING DIVISION A REAR ELEVATION 45' -6" 10" B 10" ARCH ANCHORAGE 0 ARCH FOUNDAT ION PLAN BOTTOM BOLT GRADE 8.2 3/8" d x 3/4" TIGHTEN TO 45 FT -LBS 0.075" MINIMUM STEEL BRACKET I Oi I Y I kfi 1 ,,,I ANGLE & VERTICAL LEG LENGTH MAY BE DIFFERENT FOR Q & X MODELS HILTI KB3 ANCHORS (ICC -ESR -2302) OR EQUIVALENT: 1/2" 0 x 5 1/2" BOLTS WITH 4 1/2" EMBEDDED DEPTH FOR BUILDINGS LESS THAN 30' -0" WIDE 5/8" 0x 7" BOLTS WITH 6" EMBEDDED DEPTH FOR 30' -0" WIDE AND GREATER FIRST ANCHOR BOLT LOCATION FROM END OF FOUNDATION: * 2.5" WITHOUT MANUFACTURER'S ENDWALL • 33" WITH MANFUCTURER'S ENDWALL ARCHES AND MANUFACTURER'S ENDWALLS MUST BE GROUTED INTO FOUNDATION ON BOTH SIDES OF PANELS. 4' -5' ENDWALL ANCHORAGE ENDWALL BOLT FIRST ANCHOR BOLT LOCATION: + SOLID ENDWALL = 9" FROM BUILDING CENTERLINE+18" C.T.C. + OPEN ENDWALL = 11" FROM OPENING+18" C.T.C. N cn SIDE ELEVATION 4" (min) 1 S" 9.5" 2 - #4 W.W.R. SEC A- 4" (min) 9" 2" $ 10" 18" 2 - #4 SEC B —E3 Minimum Concrete Cover: (a) Concrete Cast against earth: 3" (b) Concrete exposed to eart F. or weather: No. 6 through No. 10 bc: s: 2" No 5 bar and smaller: 1.5" (c) Concrete not exposed to carth or weather: 0.7b' 3 FIELD COPY. $. t Ns, ' 25"-2" t 10' t .9L'IT -,ET GENERAL NOTES 1. ALL MATERIAL RND WORKMANSHIP SHALL CONFORM WITH THE REQUIREMENTS OF THE LATEST REVISION OF THE INTERNATIONAL BUILDING CODE 2009. DESIGN ACCORDING TO RISI S100 -07, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS, RND WITH ANSI /RSCE 7 -05. 2. NO LOADS OTHER THAN THOSE GIVEN UNDER "DESIGN DRTR" BELOW SHALL BE IMPOSED ON THE "STRUCTURE" 3. SPECIFIC NOTES AND DETAILS SHOWN ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE BUILDING MANUAL SUPPLIED. 4. THE BUILDING, INCLUDING THE FOUNDATION, MUST BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE DRAWING AND ERECTION INSTRUCTIONS. ANY DEVIATION, UNLESS APPROVED BY US IN WRITING, SHALL NULLIFY OUR CERTIFICRTE AND SEAL AND SHALL BE THE SOLE RESPONSIBILITY OF THE ERECTOR. S. R PRGFESSIONRL ENGINEER SHOULD BE RETAINED WHERE SITE INSPECTIONS FIRE WARRANTED. 6. NO ARCH PANEL MAY BE CUT OR MODIFIED UNLESS IT IS TO ACCOMMODATE RN ACCESSORY PROVIDED BY THE MANUFACTURER IN ACCORDANCE WITH ITS INSTRUCTIONS AND /OR THIS DRAWING. FOUNDATION NOTES FRONT ELEVATION 1 = 78.31" t = 0.03" 1. = 120" t = 0.03" = 57.50" = 0.03" 1 = 84.44" t = 0.03" 1 = 78.31" t = 0.03" 1 = 120" t = 0.03" 1 = 57.50" t = 0.03" ARCH PROFILE REVIEWED FOR CODE COMPLIANCE APPROVED MAR o s 2012 A-7 kiteL of Tukwila BUI�I.DiNG DIVISION ciritVatintA FEB 2 :2012 PERMIT CENTER NOTE: THE FOUNDATION DN THE DRAWING SPECIFIES THE MINIMUM REQUIREMENTS. LDCRL BUILDING CODE RND SITE CONDITIONS MAY REQUIRE R STRONGER FOUNDATION, WHICH MUST BE DESIGNED BY R LOCAL ENGINEER. 1. THE FOUNDATION SHALL BE FOUNDED ON NRTURRL UNDISTURBED SOIL CAPABLE OF SRFELY SUSTAINING 1000 psf. THIS SHALL BE DESIGNED TO FULLY RESIST ALL ROTRTION AT THE BASE OF THE ARCH. 2. SLAB DN GRADE SHALL BE PLACED ON WELL COMPACTED SOIL CAPABLE OF SUSTAINING 1000 psf WITHOUT APPRECIABLE SETTLEMENT. DESIGN DATA (MATERIALS) 1. CONCRETE F'c = 2500 PSI @ 28 DAYS, ACI 2. REINFORCING STEEL GRADE 40, Fy = 90 KSI, RSTM 8615 3. W.W.R. Fy = 65 KSI, RSTM A185. 4. W.W.R. 6 x 6 - W1.4 x WL4 ARCH DATA 24" 7-1/2" ENDWALL DATA 18" 1- i f �r 1 i BOLTS: ERE GRROE 2 OR RSTM R307 ARCH STEEL THICKNESS - SEE ARCH PROFILE ENDWRLL STEEL THICKNESS = 0.03 in. GALVRLUME SHEET STEEL STRUCTURAL QUALITY RSTM SPECIFICATION R792 -06a 55/. ALUMINUM -ZINC ALLOY (HOT DIP COATING) RSTM R792 GRADE 50R 50 KSI MINIMUM YIELD 65 KSI MINIMUM TENSILE H5S SECTIONS SHALL CONFORM TO: ASTM R500 GRADE B (Fy = 45 ksi) W SECTIONS SHALL CONFORM TO: ASTM 8992 GRADE 50 (Fy = 50 ksi) OTHER SECTIONS SHALL CONFORM TD: RSTM R36 (Fy = 36 ksi) RRCH DESIGN DATA IN ACCORDANCE WITH ANSI /ASCE 7 -05: ROOF LIVE LORD (PSF) = 20 Pg: GROUND SNOW LORD (PSF) 25 Ce: EXPOSURE FACTOR = 1.0 Ct: THERMAL FACTOR = 1.0 IMPORTANCE FACTOR (SNOW) = 0.8 CATEGORY 1 /AGRICULTURAL BUILDING Pnet: COMPONENT W.ND PRESSURE (PSF) V : BASIC WIND SPEED (MPH) = 100 Kh: VELOCITY PRESSURE EXPOSURE = 8.85 IMPORTANCE FACTOR (WIND) = 0.87 WIND EXPOSURE CATEGORY = C SEISMIC DESIGN CATEGORY 'D2' +/- 19 LEGAL NOTE This drawing is the property of Future Steel Buildings Intl. Corp. Any duplication of this drawing in whole or in part is strictly forbidden. Anyone doing so will be prosecuted under the full extent of the law. REVISIONS: Pi uture Steel Buildings Intl. Corp, 73 rd Rd., Brampton, Ontario, Canodo, L6S 6118, Phone: (905) 790 -8500 N.T.S. SCR APPROVED BY: D-:' 1S, 2011 OAT CHECKED BY: J.B. <PA CT: DEC 1 5 2011 L: THY & THRNH DANG TUKWILA, WA A25 -14 DWG: 11 -2782 cn co 23' -9" ARCH ANCHORAGE 0 ARCH FOUNDAT ION PLAN BOTTOM BOLT GRADE 8.2 3/8" d x 3/4" TIGHTEN TO 45 FT -LBS 0.075" MINIMUM STEEL BRACKET I Oi I Y I kfi 1 ,,,I ANGLE & VERTICAL LEG LENGTH MAY BE DIFFERENT FOR Q & X MODELS HILTI KB3 ANCHORS (ICC -ESR -2302) OR EQUIVALENT: 1/2" 0 x 5 1/2" BOLTS WITH 4 1/2" EMBEDDED DEPTH FOR BUILDINGS LESS THAN 30' -0" WIDE 5/8" 0x 7" BOLTS WITH 6" EMBEDDED DEPTH FOR 30' -0" WIDE AND GREATER FIRST ANCHOR BOLT LOCATION FROM END OF FOUNDATION: * 2.5" WITHOUT MANUFACTURER'S ENDWALL • 33" WITH MANFUCTURER'S ENDWALL ARCHES AND MANUFACTURER'S ENDWALLS MUST BE GROUTED INTO FOUNDATION ON BOTH SIDES OF PANELS. 4' -5' ENDWALL ANCHORAGE ENDWALL BOLT FIRST ANCHOR BOLT LOCATION: + SOLID ENDWALL = 9" FROM BUILDING CENTERLINE+18" C.T.C. + OPEN ENDWALL = 11" FROM OPENING+18" C.T.C. N cn SIDE ELEVATION 4" (min) 1 S" 9.5" 2 - #4 W.W.R. SEC A- 4" (min) 9" 2" $ 10" 18" 2 - #4 SEC B —E3 Minimum Concrete Cover: (a) Concrete Cast against earth: 3" (b) Concrete exposed to eart F. or weather: No. 6 through No. 10 bc: s: 2" No 5 bar and smaller: 1.5" (c) Concrete not exposed to carth or weather: 0.7b' 3 FIELD COPY. $. t Ns, ' 25"-2" t 10' t .9L'IT -,ET GENERAL NOTES 1. ALL MATERIAL RND WORKMANSHIP SHALL CONFORM WITH THE REQUIREMENTS OF THE LATEST REVISION OF THE INTERNATIONAL BUILDING CODE 2009. DESIGN ACCORDING TO RISI S100 -07, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS, RND WITH ANSI /RSCE 7 -05. 2. NO LOADS OTHER THAN THOSE GIVEN UNDER "DESIGN DRTR" BELOW SHALL BE IMPOSED ON THE "STRUCTURE" 3. SPECIFIC NOTES AND DETAILS SHOWN ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE BUILDING MANUAL SUPPLIED. 4. THE BUILDING, INCLUDING THE FOUNDATION, MUST BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE DRAWING AND ERECTION INSTRUCTIONS. ANY DEVIATION, UNLESS APPROVED BY US IN WRITING, SHALL NULLIFY OUR CERTIFICRTE AND SEAL AND SHALL BE THE SOLE RESPONSIBILITY OF THE ERECTOR. S. R PRGFESSIONRL ENGINEER SHOULD BE RETAINED WHERE SITE INSPECTIONS FIRE WARRANTED. 6. NO ARCH PANEL MAY BE CUT OR MODIFIED UNLESS IT IS TO ACCOMMODATE RN ACCESSORY PROVIDED BY THE MANUFACTURER IN ACCORDANCE WITH ITS INSTRUCTIONS AND /OR THIS DRAWING. FOUNDATION NOTES FRONT ELEVATION 1 = 78.31" t = 0.03" 1. = 120" t = 0.03" = 57.50" = 0.03" 1 = 84.44" t = 0.03" 1 = 78.31" t = 0.03" 1 = 120" t = 0.03" 1 = 57.50" t = 0.03" ARCH PROFILE REVIEWED FOR CODE COMPLIANCE APPROVED MAR o s 2012 A-7 kiteL of Tukwila BUI�I.DiNG DIVISION ciritVatintA FEB 2 :2012 PERMIT CENTER NOTE: THE FOUNDATION DN THE DRAWING SPECIFIES THE MINIMUM REQUIREMENTS. LDCRL BUILDING CODE RND SITE CONDITIONS MAY REQUIRE R STRONGER FOUNDATION, WHICH MUST BE DESIGNED BY R LOCAL ENGINEER. 1. THE FOUNDATION SHALL BE FOUNDED ON NRTURRL UNDISTURBED SOIL CAPABLE OF SRFELY SUSTAINING 1000 psf. THIS SHALL BE DESIGNED TO FULLY RESIST ALL ROTRTION AT THE BASE OF THE ARCH. 2. SLAB DN GRADE SHALL BE PLACED ON WELL COMPACTED SOIL CAPABLE OF SUSTAINING 1000 psf WITHOUT APPRECIABLE SETTLEMENT. DESIGN DATA (MATERIALS) 1. CONCRETE F'c = 2500 PSI @ 28 DAYS, ACI 2. REINFORCING STEEL GRADE 40, Fy = 90 KSI, RSTM 8615 3. W.W.R. Fy = 65 KSI, RSTM A185. 4. W.W.R. 6 x 6 - W1.4 x WL4 ARCH DATA 24" 7-1/2" ENDWALL DATA 18" 1- i f �r 1 i BOLTS: ERE GRROE 2 OR RSTM R307 ARCH STEEL THICKNESS - SEE ARCH PROFILE ENDWRLL STEEL THICKNESS = 0.03 in. GALVRLUME SHEET STEEL STRUCTURAL QUALITY RSTM SPECIFICATION R792 -06a 55/. ALUMINUM -ZINC ALLOY (HOT DIP COATING) RSTM R792 GRADE 50R 50 KSI MINIMUM YIELD 65 KSI MINIMUM TENSILE H5S SECTIONS SHALL CONFORM TO: ASTM R500 GRADE B (Fy = 45 ksi) W SECTIONS SHALL CONFORM TO: ASTM 8992 GRADE 50 (Fy = 50 ksi) OTHER SECTIONS SHALL CONFORM TD: RSTM R36 (Fy = 36 ksi) RRCH DESIGN DATA IN ACCORDANCE WITH ANSI /ASCE 7 -05: ROOF LIVE LORD (PSF) = 20 Pg: GROUND SNOW LORD (PSF) 25 Ce: EXPOSURE FACTOR = 1.0 Ct: THERMAL FACTOR = 1.0 IMPORTANCE FACTOR (SNOW) = 0.8 CATEGORY 1 /AGRICULTURAL BUILDING Pnet: COMPONENT W.ND PRESSURE (PSF) V : BASIC WIND SPEED (MPH) = 100 Kh: VELOCITY PRESSURE EXPOSURE = 8.85 IMPORTANCE FACTOR (WIND) = 0.87 WIND EXPOSURE CATEGORY = C SEISMIC DESIGN CATEGORY 'D2' +/- 19 LEGAL NOTE This drawing is the property of Future Steel Buildings Intl. Corp. Any duplication of this drawing in whole or in part is strictly forbidden. Anyone doing so will be prosecuted under the full extent of the law. REVISIONS: Pi uture Steel Buildings Intl. Corp, 73 rd Rd., Brampton, Ontario, Canodo, L6S 6118, Phone: (905) 790 -8500 N.T.S. SCR APPROVED BY: D-:' 1S, 2011 OAT CHECKED BY: J.B. <PA CT: DEC 1 5 2011 L: THY & THRNH DANG TUKWILA, WA A25 -14 DWG: 11 -2782