HomeMy WebLinkAboutPermit D12-064 - BARDALES RESIDENCE - 2ND STORY AND GARAGE ADDITIONBARDALES ADDITION 10216 BEACON AV S D12-064 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 6810600030 Address: 10216 BEACON AV S TUKW Suite No: Project Name: BARDALES ADDITION DEVELOPMENT PERMIT Permit Number: D12 -064 Issue Date: 05/18/2012 Permit Expires On: 11/14/2012 Owner: Name: FEDERAL NATIONAL MORTGAGE A Address: 888 E WALNUT ST , PASADENA CA 91101 Contact Person: Name: JOSUE BARDALES Address: 366 S 306 ST , FEDERAL WAY WA 98003 Phone: 206 786 -4474 Contractor: Name: OWNER AFFIDAVIT - JOSHUE 0 BARDALES Phone: Address: Contractor License No: Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CONSTRUCTION OF 753 SF SECOND STORY ADDITION AND 318 SF ATTACHED GARAGE Value of Construction: $98,757.78 Fees Collected: $2,416.97 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 22 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -064 Printed: 05 -18 -2012 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compli N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr construction or the performance of work to this permit. me to give authority to violate or cancel the provisions of any other state or local laws regulating • I am authorized to sign and obtain this development permit and agree to the conditions attached Signature: Date: O5—Xg ? Print Name: J s�P ��rcJ4 /eS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. doc: IBC -7/10 D12 -064 Printed: 05 -18 -2012 CITY OF TUKT'" A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Pe.'it No. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: (,(b l 0U° -OOW Address: IO2tto beacon Ave 5 nu, }- kvJA, rfgi +p Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No Tenant Name: *PROPERTY OWNER Name: 0,03 uQr % O 10.\." Address: 366 5 • 3 o13-A. 5, tt Name: 3 0 5 U a4- Phone: 20b - Address: 7(e6 5, 3'nb 5 Aite - City: City: T-1 1 2de vJ ok'I State: W A Zip: ci 7003 1TACT PERSON — person receiving all project communication Name: 0,03 uQr % O 10.\." Address: 366 5 • 3 o13-A. 5, tt City: u.0\ W State: W A , Zip: 920,03 Phone: 20b - 6- 4444 Fax: 253 — 8S-13-o$3a Email: Josue 9 54. C t10* *net \\, • co feel GENERAL CONTRACTOR INFORMATION Company Name: Qt,)J Address: 312_0 f- S k. 1„Jt, S, stk. . LI 0 p 4,4u d`e_ Address: Email: ,r,` P C m aclt cs_Aw\,. tw p '' ^ City: State: Zip: Phone: Fax: State: Contr Reg No.: Exp Date: Fax: Tukwila Business License No.: Email: H:\Applicationa\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh CARCHITECT OF RECORD Company Name: MAcZE2t...L., p2aczkLE Architect Name: H 't v_ e_, e Are,rsor. Address: 312_0 f- S k. 1„Jt, S, stk. . LI 0 p City: e_ t k State: W ,A Zip: c412't._ Phone: Zoo _ 24 to - cis 3 $ Fax: Email: ,r,` P C m aclt cs_Aw\,. tw p '' ^ ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206 - 431 -3670 VithiatiOri of Project (contractor's bid price): $ 3 0 © 00 • e lJ Existing Building Valuation: $ the scope of work (please provide detailed information): u Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIREPROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Ef Other (specify) SI"1Q\ UCtc,'lt0 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes [Sr No If "yes attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 ' ' Interior Remodel Addition to Existing Structure Type of Construction per IBC Type of Occupancy per IBC lat Floor 1 2 "d Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage vio, V Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIREPROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Ef Other (specify) SI"1Q\ UCtc,'lt0 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes [Sr No If "yes attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 - PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER nR ai1THORIZED AGENT: Signature: Date: 0 Z 12-11 I Print Name: Z05 laf`� �� Day Telephone: 206- 9-g o " L1404 Mailing Address: 3 (ob SO * \ 3 Ob 5 C ce-d e'`Ak Wei v.l 1N. • c($ 003 City State Zip H:\Applications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 4 of 4 PUBLIC WORKS PERMIT INFOOTION — 206 - 433 -0179 • Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate 0... Highline ❑ ...Valley View ❑ ...Renton ❑ ...Sewer Availability Provided 0... Renton ❑... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for Tess than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water cubic yards cubic yards 0... Geotechnical Report ❑... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑... Right -of -way Use - Profit for less than 72 hours 0... Right -of -way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage O ... Abandon Septic Tank ❑... Curb Cut 0... Pavement Cut ❑... Looped Fire Line ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ ❑ .. Water Main Extension Public ❑ „ ,, „ ❑...Grease Interceptor ❑ ... Channelization 0... Trench Excavation ❑ ... Utility Undergrounding WO# (2) " WO# (3) " WO# WO # (2) " WO # (3) " WO # WO # ❑ .. Deduct Water Meter Size " Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Applications\Forms- Applications On Line12012 Apphcattons\Pemot Application Revised - 2- 7- 12.docx Revised: Febntary 2012 bh Page 3 of 4 7: Notify the City of Tukwila Building DivisiSrior to placing any concrete. This procedurlin addition to any requirements for special inspection. 8: All wood to remain in placed concrete shall be treated wood. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 13: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 14: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 15: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 17: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 20: Owner / Contractor shall notify Public Works Project Inspector Mr. Dave Stuckle at (206) 433 -0179 if any storm drainage runoff impacts adjacent properties. Existing storm drainage flow patterns shall be maintained and erosion control measures shall be in place. doc: IBC -7/10 D12 -064 Printed: 05 -18 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 6810600030 Address: Suite No: Applicant: BARDALES ADDITION 10216 BEACON AV S TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: D12-064 ISSUED 02/29/2012 05/18/2012 Receipt No.: Initials: User ID: R12 -02491 WER 1655 Payment Amount: $63.00 Payment Date: 08/29/2012 03:18 PM Balance: $0.00 Payee: JOSUE BARDALES TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 101472 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts PLAN CHECK - RES 000.345.830 Total: $63.00 63.00 doc: Receiot -06 Printed: 08 -29 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 6810600030 Address: 10216 BEACON AV S TUKW Suite No: Applicant: BARDALES ADDITION RECEIPT Permit Number: D12-064 Status: APPROVED Applied Date: 02/29/2012 Issue Date: Receipt No.: R12 -01634 Payment Amount: $1,466.60 Initials: JEM Payment Date: 05/18/2012 02:37 PM User ID: 1165 Balance: $0.00 Payee: PSA LLC, JOSUE BARDALES TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 123774 ACCOUNT ITEM LIST: Description 1,466.60 Account Code Current Pmts BUILDING - RES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,466.60 1,462.10 4.50 doc: Receiot -06 Printed: 05 -18 -2012 of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -00863 Initials: JEM Payment Date: 02/29/2012 User ID: 1165 Total Payment: 1,066.92 Payee: JOSUE 0 BARDALES SET ID: S000001704 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -064 EL12 -0199 TOTAL: 950.37 116.55 950.37 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,066.92 TOTAL: 1,066.92 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - RES 000.322.101.00.0 PLAN CHECK - RES 000.345.830 TOTAL: 116.55 950.37 1,066.92 _1:41 INSPECTION RECORD Retain a copy with permit INSPECTION NO. _ @ERMIT44O- CITY OF TUKWILA BUILDING - DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: (1A le- D4LS A j I:(--* Type of Inspection: F J A L Address: 0)2.1 {n rleiNN3 3 AO Date Called: Special Instructions: Date Wanted:. )O_ 2+ -12 a.m.' p.m. Requester: Phone No: .zUlo- 7 66.- LI4i 7 4-/ Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: Da /14 'T"" tot re,t • -g(advt_ Inspe to r: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Aco INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206).431-3670 .)1z -o0-/ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: 13PA 141-fS A4 /i /0A/ Type of I,� f r1J.r_3 Inspection: �IM i Address: /02 / L. i3Fa00"/ 44d S Date Called: Special Instructions: Date Wanted: .CM; 9- AO -iZ p.m. Requester: Phone No: dA46-- 786— .47/hi7q Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: ),A Ins15ector: 1a Date n REINSPECTION FEE REQ' to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Projec /yam eu es •U Type of Inspection: 01c- t—t---0 c() 1/4 i - t t" —`- r A c ft- e la: c r dfr .r--A.C. Address: Datalled Special Instructions: Date Wanted �.,m.,, Requester: . Phone j -77 tr ‘ -+4'71 ElApproved per applicable codes. Corrections required prior to approval. S COMMENTS: 01c- t—t---0 c() 1/4 i - t t" —`- r A c ft- e la: c r dfr .r--A.C. Cce 1.'I Eco t',. -ftgu 6t. P(J,-ka • {J i Yom; (.4) c)-(**-- Gam- ;'A 6 S- i j;(j1'ave.d Inspector: Date ri REINSPECTION FEE REQUIRED rior to next inspection, fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSPECTION 0. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ��(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 biz -06,1 Project: PS kA(1."ts \) II Type of Inspection:, 1}- M4A(0 O j1\ cJi. e co r lei' S Cb. _ (iu),....iotkii . D a(9 2S i ±.taa Address: ((21(p 34.4 c43A/ Date Called: po A- prif an& Special Instructions: , Date Wanted•, -7 "" (-le' / Z.:, p.m. Requester: Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS: O j1\ cJi. e co r lei' S Cb. _ (iu),....iotkii . D a(9 2S i ±.taa po A- prif an& Inspect€ &qk Ji _ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.• Date J /4r jam' L3 INSPECTION RECORD Retain a copy with permit ,1 1, � /2 —cg y INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F' (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ,C 1".-dq%4 4h/ Type of Inspection: Address: 44—Date [ate Called: Special Ins ructions: " Wanted:. a m. Requester: Phone No: ElApproved per applicable codes. COMMENTS: Corrections required prior to approval. _� REINSPECTION FEE R QUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 L Project: Q� A.r-4teS Add s, i� Type of Inspection: a4(A Ld Ske4 Address: I 0 2/6 gkA -'-o4 4Jf- Date Called: Special Instructions: Date Wanted:. r m. Requester: Phone igo 44 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: f Datei 7 5 I Inspect�r: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • • • • • • • W12 —0(1( r••• INSPECTION RECORD Retain a copy with permit • INSPECTIONNO. PERMIT NO. _ CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 0 Permit Inspection Request Line (206) 431 -2451 Project: . * g, AL E, S ,Arlo 8;1 bA/ Type of Inspection: „-F--; ^ 6 Address: 10" 2 to 2 e4 64Ar A Date Called: Special Instructions: . Date Wanted:. -3 / —/2._ a.m p.m. Requester: Pone No: ,,g aCf Approved per applicable codes. E Corrections required prior to approval. COMMENTS: '9A6'11.-4 ok1K Ins ect r: 04\ Date: .ri IREINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. _ _A • ... • • IN . ...- oN RECO,RD _, .7 .::. Iff Roas, '. . with permit INSPECTION NO. ,...,..,Q. :-,,3. - P RMIT NO • ..:." ' ,.;... . CITY OF TaKVVA*BUILDING DIVISION . 6300 Southenter Blvd., #1.00; TukWila. WA 513188 - (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: w i t Me, A01-4'1. Type of inspe .00 cti°5 Address: - Aakt t FICICAM ki C Date 'Called: 1°W. \ 1 eL- • Special Instructions: . ' Date Wanted: C.P _.....- Requester: „...----,, ■ cf-AA e 1 Phone No: • 7-067 1 Ill 41414 ]Approved per applicable codes. COMMENTS: Corrections required prior to approval. t. --irsiAeLte,z1 1.1:11.• Insbector: 9s Date: 6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. !. F D FILE COPY LIVE - FAMILY - DESIptrmft No. STRUCTURAL ENGINEERING, LLC 23201 SE 135'h Ct - ISSAQUAH, WA 98027 ph: 206.941.3334 - efax: 800.934.9676 email: cfraser @structurallfd.com Structural Calculations for: Beacon Ave S. Residence Project Address: 10216 Beacon Avenue S Tukwila, WA 98178 Design per 20 09 International Building Code REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 A 2012 • City of Tukwila BUILDING DIVISION EAPJ b2,1 g. fori Contents: Gravity Design Gi — G3 Kzt Determination K, -1 — Kzt-3 - Kzt =1.00 per the site specific profile sheets on Kzt -2 & Kzt -3 Lateral Design L1— L5 Allowable Bearing Pressure2,000 PSF (No Geotechnical Report)o. CITY F1'�D� i A APR 2 4 2012 PERMIT CENTER Plq_0(oLl Seismic Design Loads (ASCE 7 -05) for a Wood Framed Structure OCCUPANCY CAT. II IMP. FACTOR 1 SITE CLASS D R = 6.5 h = 21.005 Ss = 1.495 S1= 0.515 Fa = 1 F„= 1.5 Sips= 0.996666667 SDI= 0.515 Table 1 -1 Table 11.5 -1 Table 20.3 -1 Table 12.2 -1 ft 2005 ASCE 7 Standard(http: / /earthquake.usgs .gov /research/hazmaps /design/) 2005 ASCE 7 Standard( http:I /earthquake.usgs .gov /research/hazmaps /design/) Table 11.4 -1 Table 11.4 -2 Period, T= 0.196232985 Eqn. 12.8 -7 C5= 0.153333333 Eqn. 12.8 -2 Csmax= 0.403758671 Eqn. 12.8 -3 Csmin= 0.01 Eqn. 12.8 -5 Valli = 0.74 *Cs *W 0.74 per Table C11 -2 from ASCE 7 -05 Base Shear, V = 4465 Ibs Shearwalls DL (psf) A (sq.ft.) W ( #'s) hx (ft) W *hx C„x Lat. Load (Ibs) 2nd Fir Shearwalls 13/5 1034/743 17157 21.005 360382.79 0.6111413 2729 1st Fir Shearwalls 21/13/5 743/385/318 22198 10.33 - 229305.34 0.3888587 1736 Sum= 39355 Sum= 589688.13 Diaphragm Forces (per ASCE 7 -05 12.10.1.1) level lower limit upper limit sum F sum W calc'd force Diaphragm Load (Ibs) Roof 2633 5267 2729 17157 2729 2729 2nd 3407 6814 4465 39355 2519 3407 L F LIVE - FAMILY - DESIGN STRUCTURAL ENGINEERING, LLC 23201 5E135" Ct - I55AQUAH, WA 98027 ph: 206.941.3334 - efax: 800.934.9676 email: cfraser@structurallfd.com Project: Beacon Avenue Residence 10216 Beacon Ave S Tukwila, WA 98178 Date: 04.20.12 Project #: 12 -043 Design: CMF Sheet: L1 Wind Design Loads (ASCE 7 -05) Method 2 - Analytical Procedure Exposure B V= 85 mph Kd= 0.85 1= 1 G= 0.85 Table 6-4 Table 6 -1 6.5.8.1 Topography from Figure 6-4 Terrain= escarpment (ridge, hill, escarpment) Site= up (UPwind or DOWNwind) H= 315 ft Lh= 2904 ft x= 1584 ft z= 12 ft p= Y= K1 value = K1= K2= K3= 1.5 2.5 0.75 0.08 0.64 0.99 Roof Angle = Ground to top of roof Bottom of roof to top of roof (mean roof height) h= height of topography distance from H/2 to crest >0 distance from crest to site Height from bottom of topo. to site Kn= (1 +K,KZK3)2= 1.00 I Per site specific profiles for site; see Kzt -2 and Kzt -3 17 23.67 5.33 21.005 degrees ft ft ft Pressure Coefficients from Figure 6 -6: Bldg Face Cp Windward Wall Leeward Wall Windward Roof 0.8 -0.5 0.2 Leeward Roof -0.6 'Note= Cp values are conservative worst case values Pressures: Ht Kz qz i Pww walls Plwwalls Pwalls (psf) 0 -15 0.57 8.96 6.09 4.41 10.50 15 -20 0.62 9.75 6.63 4.41 11.04 20 -25 0.66 10.38 7.06 4.41 11.47 25 -30 0.7 11.01 7.48 4.41 11.89 30-40 0.76 11.95 8.12 4.41 12.53 Proof (psf) 7.06 L F LIVE - FAMILY - DESIGN STRUCTURAL ENGINEERING, LLC 23201 SE 135' - ISSAQUAH, WA 98027 ph: 206.941.3334 - efax: 800.934.9676 email: cfraserstructurallfd.com Project: Beacon Avenue Residence 10216 Beacon Ave S Tukwila, WA 98178 Date: 04.20.12 Project #: 12 -043 Design: CMF Sheet: L2 Site Specific Profiles for Residential Addition at 10216 Beacon Ave 5, Tukwila, WA 98178 Site Profile#3 — Northwest to Southeast Direc ion 400 ft 300 200 100 or r r 1 0.0 1.0 2.0 3.0 4.0 5.0 miles Left side of profile is southeast and right side of profile 15 northeast Analyze as escarpment from northwes H=IIS''Lh=.]O Miles (1684')'X=O Miles, z=1Z'-0f Analyze as ridge from northwest —H=3l5'Lh=.5S Miles (29O4')'X~3O(1SO4)'z=1Z'-0" Analyze as escarpment per sheet L2 - Kzt = 1=0{L_ Analyze as ridge per sheet L3'Kzt=1'00 Site Profile#4 — Southwest to Northeast Direction 1.5 2.0 ' 2!5 3.0 Miles Left side of profile 15 northeast and right side of profile 15 southwest Kzt = 1.00 by inspection when analyzed as an escarpment or ridge ; location of site (escarpment location) for wind Ioads from the southwest direction results in the 1.00 value; the escarpment is not at a height greater than a factor of 2 within 2 miles from the point; the upwind terrain feature comes into play as a factor less than 2 at approximately 1.25 miles to the west (Per Section 6.5.7.1 of ASCE 7-05); Kzt = 1.00 by inspection when analyzed as a ridge from the northeast; the location of site relative to the peak ofthe ridge is too great, resufting in the 1.00 value Site Specific Profiles for Residential Addition at 10216 Beacon Ave 5, Tukwila, WA 98178 Site Profile#1 — South to North Direction 300 ft 200 100 0.0 110 2.0 3.0 I 4.0 miles Left side of profile is north and right side of profile is south Analyze as escarpment from north - H = 220', Lh = .60 Miles (3168'), X = 0 Miles, z= 12' -0" Analyze as ridge from south — H = 345' Lh = .20 Miles (1056'), X = .50 (2640'), z = 12' -0" Analyze as escarpment per sheet L2 - Kzt = 1.00. Analyze as ridge per sheet L2 - Kzt = 1.00 Site Profile #2 — West to East Direction 300 ft 200 100 0+ 0.0 1.0 2.0 Left side of profile is east and right side of profile is west 3.0 4.0 miles Analyze as ridge for wind from the west — H = 390', Lh = .55 Miles (2904'), x = .50 Miles (2640 ft), z = 12' Kzt = 1.00 by inspection when analyzed as an escarpment ; location of site (escarpment location) for wind loads from the west direction results in the 1.00 value; the escarpment is not at a height greater than a factor of 2 within 2 miles from the point; the upwind terrain feature comes into play as a factor less than 2 at approximately 1.25 miles to the west (Per Section 6.5.7.1 of ASCE 7 -05) Kzt = 1.00 per L2 when analyzed as ridge Kzt -2 Wind Speed Up Areas Page 8 of 8 L.o.Ad wna @p.W Up AM. Sp... Up fWen .3.• w T �wr•� tpaww C'AOW _w rw *p.m- ..ty1• • ti° o .00 1.000 ]000 1000 ♦011 MO d a. ten. P'.,.i„s.nnc,. rnwrtnefft "come,. Yeas, Ceonon 20 :0N Po, Aeurw, Ch a 0.20. ...Prat AO r0 0010 W 0,04. AN�wz SrE ,SPkciHc P� Pi LE "D .te 1"o 5ITF EL4T 'E "fio 5.A-'t-LE 3,96'5 W1rJ tNG1NkLRtNU MAC 1t) OtZMAT)Di) Sec Iwo .1,t 4 LJ� \il kve 7ft ) 44:0 2.;>44-t 4.% LFb LIVE - FAMILY - DESIGN ) STRUCTURAL ENGINEERING, LLC I 23201 5E 135" Ct - ISSAQUAH, WA 98027 ph: 206.941.3334 - efcx: 800.934.9676 cfroser@structurallfd.com Y.1 ors 1-4 „e Ef,,,fa 1,cir s Tvo Ave. DATE:454 2.47... PROJECT: PROJECT ADDRESS: DESCRIPTION: PROJ. DESIGN: CMF SHEET: (.; 1 2..534)K— k._ a.^! J} L --A:, c 4i 144' �. F kiLuc- -err Lj4 LIVE - FAMILY - DESIGN PROJECT: . :.,,/ STRUCTURAL ENGINEERING, LLC PROJECT ADDRESS: DESCRIPTION: 23201 SE 135" Ct - ISSAQUAH, WA 98027 ph: 206.941.3334 - efox: 800.934.9676 email: cfroser@structurallfd.com DATE: 014,.Z.,*? PROJ. NO: 17-v-1 DESIGN: CMF SHEET: `w" DESIGN PER 2009 SBC: DESIGN LOADS: LEVEL LIVE DEAD TOTAL .75(SorL) ROOF 25 PSF 13 PSF 38 PSF 31.75 PSI FLOOR 40 PSF 11 PSF 51 PSF 41 PSF DECK 40 PSF 5 PSF 45 PSF 35 PSF INTERIOR WALL = 9.00 psf EXTERIOR WALL = 13.00 psf LOAD COMBINATIONS CONSIDERED: 1.0L +1.0D +OS 1.0S +1.0D +OL .75L +.75S +1.OD 1.0(Eq or W) +0(L 8Jor S) +(D or.6D) .75(S, L) +D +.75(Eq or W) DEAD LOADS: ROOF FRAMING = TRUSSES @ 24 "OC TRUSSES @ 24 "OC = (1.5/12) *(5.5/12) *.46 *62.4PCF *4.0 = 6.58 pif / 24 "OC = 3.29 psf NOTE: .46 = SPEC. GRAVITY OF H.F. MAT'L; 62.4PCF = DENSITY OF HD); 4.0 IS # OF 2x6's PER LINEAR FT ASSUMED FOR WT - INCLUDES TOP & BOT CHORDS, & DIAGONAL TRUSS MEMBERS ROOF FINISH = 2.50 PSF 5/8 "GYPSUM CEILING = 2.8 PSF INSULATION = 1.00 PSF 7/6" OSB (OSB HEAVIER THAN CDX) = 1.8 PSF SUM = 11.39 PSF USE 13.00 PSF FLOOR = 2x10's @ 16" OC; DECK = 2x8's @ 16 "OC 2x1 O's = (1.5/12) *(9.25/12) *.46 *62.4 pcf = 2.77 plf *(12/16 ")C) = 2.08 psf DECK = 2x8's = (1.5/12) *(8.25/12) *.46 *62.4 pcf = 2.17 pif *(12/16 ")C) = 1.63 psf FLOOR FINISH = 3.00 PSF (WOOD FLRS, CARPET OR STD TILE) DECK FINISH = (.75/12) *(12/2) *.36 *62.4 PCF = 1.40 PSF (CEDAR FINISH ASSUMED w/ SPEC. GRAVITY = .36) 5/8 "GYPSUM CEILING = 2.8 PSF 3/4" OSB = 2.7 PSF SUM = 10.58 PSF FLOORS SUM = 3.03 PSF OPEN DECK USE 11.00 PSF USE 5.00 PSF EXTERIOR WALL = 2x6's @ 16 "OC 2x6 @ 16 "OC = 1.64 plf * (12/16) = 1.24 psf TOP PL's & BOT PL = 1.65 pif*3 = 4.94 r "GYPSUM WALL = 2.2 PSF 2" OSB = 1.8 PSF INSULATION = 0.50 psf SIDING = 2.3 psf (HARDY PANEL) SUM = 12.98 psf USE 13.00 psf INTERIOR WALL = 2x4's @ 16 "0C w/ 2' GYPSUM EA SIDE SUM = .79 psf + 3.14 psf + (2) *2.2 psf + MISC = 9.00 psf LFD LIVE - FAMILY - DESIGN PROJECT: Beacon Ave Residence - PROJECT ADDRESS: 10216 Beacon Ave S STRUCTURAL ENGINEERING, LLC DESCRIPTION: Design Criteria 23201 SE 135TH CT ISSAQUAH, WA PH:206- 941 -3334 DATE: 04.22.12 PROJ. NO: 12 -043! DESIGN: CMF SHEET: G1 1 �. wq; y, City of Tukwila o a� Jirn Haggerton, Mayor Department of Community Development Jack Pace, Director November 16, 2012 Eastgate Environmental Health Services King County Wastewater Program 14350 SE Eastgate Way Bellevue, WA 98007 RE: Parcel #6810600030, at 10216 Beacon Avenue S., Tukwila, WA Subject: Building Pen-nit D 12 -064 Dear Sirs or Madams: It has come to my attention that we have issued a building permit and final inspection approval for the dwelling at the above referenced address. In the course of our permit process the fact that the dwelling was not on a public sewer system was not discovered. An existing septic system serves this dwelling. The remodel included a second floor addition to provide three new bedrooms and a new bathroom. No review of the existing septic system was completed by Environmental Health Services. This letter is for your information should you determine that further action is necessary. Sincerel Rob-rt Benesicto, Building Official City of Tukwila 206/431 -3675 Bob.benedicto @tukwilawa.gov CC. Michael Cusick, Senior Engineer Tukwila Public Works Josue Bardales, Owner City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite 100 Tukwila, WA 98188-2599 JOSUE BARDALES 366 S 306th Street Federal Way, WA 98003 City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite 100 Tukwila, WA 98188-2599 BARDALES 10216 BEACON AVE S TITT(Wil A WA QR1 May 1, 2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Josue Bardales 866 S 306th St Federal Way, WA 98003 RE: Correction Letter #2 Development Permit Application Number D12 -064 Bardales Residence —10216 Beacon Av S Dear Mr. Bardales, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire and Public Works Departments have no comments. Planning Department: Jaimie Reavis at 206 431 -3659 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, c Bill Rambo Permit Technician encl File No. D12 -064 W: \Pennit Center \Con•ection Letters\2012\D12 -064 Correction Letter #2.doc 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • • PLANNING DIVISION COMMENTS DATE: April 27, 2012 APPLICANT: Josue Bardales RE: D12-064 ADDRESS: 10216 Beacon Ave S (parcel #681060 -0030) Please review the following comments listed below and submit your revisions accordingly. 1) The roof of the garage addition has a roof pitch of 4:12. The minimum roof pitch requirement, per TMC 18.50.050 Single Family Dwelling Design Standards, is 5:12. This comment was sent previously as part of Comment Letter 1. Please revise plans and the design of the garage addition to include a minimum roof pitch of 5:12. If you have any questions related to the comments above, Jaimie Reavis is the planner assigned to the file and can be reached at 206 - 431 -3659. April 23rd, 2012 Material Practice Mike Peterson, Architect 1506 1 l th Avenue Seattle, WA 98122 206 - 276 -9538 mp @materialpractice.com Dave Larson, Senior Plan Examiner City of Tukwila Building Division Re: Bardales Addition, 10216 Beacon Avenue South 1 materialpracke �LA G1Y R APR 2 4 2012 } RAAITCENTER Dave, Thank you for the notes regarding our project. The drawings have been corrected, please see our responses to your corrections below: 1. Lateral Wall Bracing. Please see the attached calculations from LFD Engineering. 2. Beams Supporting Roof Trusses. The beams have been noted, please see sheet A2.3. 3. Second Floor Framing. The Upper Floor Framing Plan on sheet A2.3 has been revised to show doubled joists and hangers. 4. Egress Windows. The note regarding egress windows on the upper floor has been revised to reflect the 5.7 square foot requirement, sheet A2.1. 5. Garage Roof Ledger. The garage roof ledger connection assembly has been added to sheet A2.3. 6. Glulam Beam and Footing. Please see the attached calculations from LFD Engineering. 7. Deck Attachment. The deck attachment detail on sheet A6.1 has been revised to reflect the prescriptive design from IRC R502.2. 8. Safety Glazing. The windows noted have been revised to require safety glazing, please see sheets A2.1 and A3.1. 9. Sloped Garage Floor. A note has been added requiring a sloped garage slab, sheet A2.1. 10. Carbon Monoxide Detectors. Carbon Monoxide Detectors have been added on both floors, please see sheet A2.1. 11. Attic and Crawlspace Access. Attic and Crawlspace Access have both been added to the plans, please see sheet A2.1. Please feel free to contact me anytime via phone or email to clarify any of the corrections above. Sincerely, Mike Peterson March 22, 2012 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Josue Bardales 866 S 306th St Federal Way, WA 98003 RE: Correction Letter #1 Development Permit Application Number D12 -064 Bardales Residence —10216 Beacon Av S Dear Mr. Bardales, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Planning Departments. At this time the Fire and Public Works Departments have no comments. Building Department: Dave Larson at 206 - 431 -3678 if you have questions regarding the attached comments. Planning Department: Jaimie Reavis at 206 431 -3659 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D12 -064 W:\Perrnit Center\Correction Letters \2012\D12 -064 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Tukwila- Juilding Division' Dave Larson, Senior Plan Examiner Date: March 12, 2012 Project Name: Bardales Addition Permit #: D12 -064 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plans do not show the method of lateral wall bracing. A structural engineered design is one option. The second option is to use a wall bracing method from the International Residential code. If the second option is used, the load transfer to the foundation including first floor brace walls and connection of the structure to the foundation will need to meet the current code requirements. Please provide an engineered design or the IRC method of wall bracing. First and second floor brace walls should be shown on the respective floor plans. Foundation anchoring details meeting the 2009 IRC will need to be included. 2. The roof trusses above the second level deck will need to bear on beams at their ends. The plans do not show these members. 3. The opening in the second floor framing for the stairway is supported by one pier footing. Please show the framing of the second floor including multiple joist or beams around this opening and any framing connectors required to show the load transfer to the foundation system. 4. Notes on the plan state that bedroom emergency egress windows need to have 5 square feet of opening. The second story windows need 5.7 square feet. Please revise these notes. 5. Provide a detail for the garage roof ledger connection to the second story wall framing. 6. Provide the method used to size the glu -lam beam. Note also that the first floor interior wall in line with the glu -lam will be supporting floor load from above. This wall is not fully supported by a linear footing. The plans show a 24 inch by 24 inch pier at the end of the glu -lam. A beam or continuous footing is needed to support the floor load above this wall. Please revise • Page 1 1 • plans as necessary. Also note that the 24x24 pier appears to be slightly under sized. Please provide tributary area calculations used to size this pier. 7. Detail 3 on A6.1 shows a 3/8 x 2' /z lag at 16 inches O.C. for attachment of the deck ledger to the house. Section R502.2.2 of the IRC has a prescriptive requirement for this connection. Please revise the plans to match this code section or provide a engineered attachment. Also see section 502.2.2.3 for a required lateral support connection. Please add this to the plans or provide an engineered design. 8. The windows adjacent to the stairway may need to be safety glazing. Please note on the plans as such or provide the exceptions used from section R308.4 IRC. 9. Please add a note to the plans stating that the garage floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. 10. One carbon monoxide detector will be needed just outside of the bedrooms on each floor. Please add these to the plans. 11. Please show the attic and crawl space access on the plans. Should there be questions conceming the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. • Page 2 • • PLANNING DIVISION COMMENTS DATE: March 13, 2012 APPLICANT: Josue Bardales RE: D12-064 ADDRESS: 10216 Beacon Ave S (parcel #681060 -0030) Please review the following comments listed below and submit your revisions accordingly. 1) The roof of the garage addition has a roof pitch of 4:12. The minimum roof pitch requirement, per TMC 18.50.050 Single Family Dwelling Design Standards, is 5:12. Please revise plans and the design of the garage addition to include a minimum roof pitch of 5:12. If you have any questions related to the comments above, Jaimie Reavis is the planner assigned to the file and can be reached at 206 - 431 -3659. •ERMIT COORD COOP PLAN REVIEW /ROUTING SLID ACTIVITY NUMBER: D12 -064 DATE: 08/23/12 PROJECT NAME: BARDALES ADDITION SITE ADDRESS: 1021.6 BEACON AV S Original Plan Submittal Response to Incomplete Letter Response to Correction Letter # X Revision # 1 after Permit Issued D PA ENTS: ' Z B it !rig I ision rOl Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 08/28/12 Not Applicable ❑ Comments: • Permit;Center Use Only: INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required, REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DUE DATE: 09/25/12 REVIEWER'S INITIALS: DATE: Permit Cgnte: .n. •may'{ '6.. CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • PERMIT GO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -064 PROJECT NAME: BARDALES ADDITION SITE ADDRESS: 10216 BEACON AV S Original Plan Submittal X Response to Correction Letter # 2 DATE: 05 -15 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural 44-e Planning Division n Permit Coordinator = R DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 05 -17 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route T. Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions n Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 06 -14 -12 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *PERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -064 DATE: 04/24/12 PROJECT NAME: BARDALES ADDITION SITE ADDRESS: 10216 BEACON AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: A-T k Building Division IN Fire Prevention n nI Planning Division Public Works ❑ Structural ❑ Permit Coordinator I I DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 /26/12 Complete Incomplete Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 05 /24/12 Not Approved (attach comments) DATE: 17a Permit Center Use Only CORRECTION LETTER MAILED: `1 ( Departments issued corrections: Bldg ❑ Fire ❑ Ping'' PW ❑ Staff Initials: use Documents /routing slip.doc 02/29/12 iI�ERMIT COORD CORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -064 PROJECT NAME: BARDALES ADDITION SITE ADDRESS: 10216 BEACON AV S DATE: 02/29/12 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ' ed, w12.it Aim MLA o&iiYL WvVi 4 B iG�ng Ivlslon � Fire Prevention -Vic k Public r s Structural • bald 03` 14, i2 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 03/01/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW El Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 03/29/12 Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: '� Departments issued corrections: Bldg Fire ❑ Ping PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 PROJECT NAME: SITE ADDRESS: fklk-C ► 111 A119 PERMIT NO: • S ORIGINAL ISSUE DATE: oro tl) REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIA LS 24 r D •y4V 1?- apt Summary of Revision: C GE of I�(4 'V LNCIAA,ID 6 12-1 (N Gin ,�tlIQN p & 0 CAMI Cr 4 Received by: C :_— _ REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) CityIf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc. Date: 1-- 2 3 — 1 Z Plan ChecWPermit Number: 1)17_ _ O 6 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: 'Boyd OA e S R C\ . V i O y\ Project Address: W Q Z t & 'Beacon J i 5 11 .A tw ∎ 1G. 'Js) q o' I f lr Contact Person: —O 5 `�cnye\ n t P S Phone Number: Z c (, 6 y 4-11 Summary of Revision: ‘---Pen/DC/t° crl- er;oy 6—vr3 On 1' �iooY, l?. acid O 15 insU /a2;cn and New Lu c,A- Nh e EX .ter; o - o,\\ S REc 32012, cg Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit C - nter b PEntered in Permits Plus on � 3( H:\Applications\Forms- Applications On Line\20I0 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan ChecWPermit Number: lQ Date: 5// 27 I /20 12- ❑ Response to Incomplete Letter # Response to Correction Letter # 2- ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ardhle s %rd dl4ro v1 Project Address: /bZl (a 13PGi(D7l Ave S Contact Person: Uv5U2 r) crc.1 tt (o S Phone Number: 2-06o- " LI Lt7 L/ Summary of Revision: Nn o'vis 10914 ct ,eic /y ; ;r�C r�c7 ;r11,71P- &rt � effire, s, kgCe - Farm l y 4 s1 d / s CTwtc i �'. sno. os C�) , PI rims rip heft gap& -17) 1� P - yMed 4o Q i n d' h v-P . 1 r i4 rt avv, 104, eGP ?Ian , K . r [C �y � RECEIVED zo1Z PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision includiate of r Received at the City of Tukwila Permit Center by: la" Entered in Permits Plus on 5.-1S--( H: Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: //www.ci.tukwila.wa.as REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 0 q /Z 4' // Z Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: /3 20 w" Project Address: • , Contact Person: S V e '3 QA ei a \ Q. S nit -o(91{ errMarluva4 It LA APR 24 2012 PERMIT CENTER Phone Number: a 0 G 7 8.6 W ti 74/ Summary of Revision: f )ease see, critac,G� m + Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: /? ■1/■-* tylEntered in Permits Plus on HAApplicathasIFannsApplicatans on Lnc 2010 Applic<da nO -2010 - Revision Submittal.dac Crowd: 0434001 Revised: 7 -2010 1 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431-3665 E -mail: tukplan@ ci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: 'NI 4 STATE OF WASHINGTON) COUNTY OF KING ss. J O S 13 QY d Q\ e S , states as follows: [please print name] EU,2- DIgS 1. 1 have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owner /Owner's Agent* Signed and sworn to before me this day of , \ 20 . NOTARY PUBLIC in and for the State of Washington ‘-I Residing at \, County Name as commissioned: \k.( \ ` ,' My commission expires: tt \ I ^ 1 18.27.090 Exemptions, The regition provisions of this chapter do not apply 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to Bearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed to by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical-contractor's license under chapter 19.28,-RCW that emp16yv a certified journeyman electrician, aa•bertified residentral secialty electrician, or an electrical'tiainee meetingA e requirements of chapter 19. S RCW to perfo)m plumbing work that is incidentally, di illy, and immediately appropriate to the like-in -kind replacement oj' a household appliance or other small household utiilization.'e aiipment that requires limited electric power•andliniitedpaste and /or water connections. A i'electriica1 trainee must be supervised by a certified e1e ciao wwhile pe'Rorming plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. LEGEND NEW STUD WALL -2x4 @ 16" O.C. (INTERIOR) -2x6 @ 16" O.C. (EXTERIOR) EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED LINE OF CONSTRUCTION ABOVE OR HIDDEN FROM VIEW SECTION / PAGE NUMBER REFERENCE FLOOR PLAN NOTES: 1. VERIFY ALL EXISTING DIMENSIONS, INCLUDING WALL LOCATIONS, WALL HEIGHTS, WINDOW SIZES, AND DOOR SIZES. 2. WINDOW SIZES INDICATED ARE ROUGH OPENING. 3. DOOR SIZES INDICATED ARE SLAB, NOT ROUGH OPENING. 4. ALL NEW EXTERIOR WALLS TO BE 2x6 @ 16" O.C. WITH R -21 INSULATION, EXCEPT GARAGE WALLS. 5. INTERIOR PARTITIONS TO BE 2x4 @ 16" O.C. 6. PROVIDE SMOKE DETECTORS IN ALL BEDROOMS. 7. EGRESS WINDOWS TO HAVE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING AREA OF 5 SF, MIN. CLEAR OPENING HEIGHT OF 24 ", AND MIN. CLEAR OPENING WIDTH OF 20 ". EGRESS WINDOWS TO HAVE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING AREA OF 5 SF, MIN. CLEAR OPENING HEIGHT OF 24 ", AND MIN. CLEAR OPENING WIDTH OF 20 ". 0 M GARAGE ROOF BELOW 24' -0" 4' -6" 3' -0" 9' -0" 3' -0" 4' -6" j / /O /OD000 /ODO /% /OO Illlllllll 6/.OD/000/l00/O/O/O ��s i it 2868 io M EGRESS WINDOWS TO Hi YE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING AREA OF 5.7 SF, MIN. CL.E;R OPENING HEIGHT OF 24 ", AND MIN. n :LE4R OPENING WIDTH OF 20 BEDROOM 0 z� U- Z U) MIN. 36" GUARDRAIL, PROVIDE 1.5" DIA. HANDRAIL 12' -4" 3' -2" 10' -4" 9 IC) 5' -0" LIVING AREA -PROVIDE (1) CARBON MONOXIDE DETECTOR JLST 3068 OUTSIDE THE BEDROOMS `i ON EACH FLOOR 0 ALL WINDOWS GLASS IN BATHROOMS TO BE LAMINATED OR TEMPERED SAFETY GLAZING PER IRC R308.4 O BATHROO M v n. • 4 SD 2668 BEDROOM BEDROOM 12' -4" 10' -0" L- 9 0 T 9 0 M r` ROOF BELOW O u- • E N > 9' -9" 4' -5" 6' -0" 26' -0" NEW UPPER FLOOR PLAN SCALE: 1/4" = 1' -0" NORTH 0 —'D FOR: Mechanical Electrical Plumbing Gas Piping Cy of Tukwila ca DIVISION R[-VIS,ONS No changes shan he male to the scope of work Withc' : prior approval of Tuker ila E' Tiding Division. j f -" rz ^:vi3;cns will '_quire a new plan submittal i:nj may in,'udie a,' tion I plan review fees. r -r c- ac+&IL f_I..) FOR ODE COMPLIANCE APPROVED AUG 2 9 2012 City of BUILDING i iSiON 24' -0" 9 0 0 FILL Permit Na., Pa , PlIn review approval is subject to errors and ornissons. Ar,,hicval of construction documents doss net ai hi 479 the violation of any adopted code or ardinanc •. ?c; pt 01 approved Field Copy and conditions is acknowiedg d-' By Date :. City Of 1'Ukwil'a BUILDING DIVISION 10'x7' GARAGE DOOR NEW GARAGE ADDITION \ i SLOPE CONCRETE SLAB TOWARDS GARAGE DOOR TO PROMOTE DRAINAGE ro 04e °l b aUa✓'{ av'rN^ --nvr a P p U cwt.( .s l o 13 R @ 7.75" 14 T G 10 M� M N INN -I NEW STAIR EXISTING C7 z 1 ` cn X w a II REMODELED KITCHEN u gP a C7 z a a w w c0 LIVING AREA a w m wLi z L -- DEMO WALLS PROVIDE (1) CARB',Ottl MONOXIDE DETECTOR JUST `\• OUTSIDE THE BEDROOMS \ ON EACH FLOOR EXISTING I' 00 00 BATHROOM EXISTING - NO CHANGE SD u II r BEDROOM MODIFIED CLOSET MAIN FLOOR PLAN EXISTING SCALE: 1/4" = 1' -0" z 1- X w EXISTING DECK EXISTING - NO CHANGE O z 1-= w NORTH 1 PROVIDE MIN. 24 "x24" CRAWLSPACE ACCESS f�_® --� h� off- e * -w 3 ,neY,c��' 'Re move sd1o01;3 „'�;o” `r-, u) c3 RE ' r vt CITY o` TlUKW LA AUG 2 3 2012 PERMIT CENT Ca F CI AP'! ' 4 2012 ISIONPER ITC u udf LA Material Practice 3220 First Ave South, Suite 400 Seattle, WA 98122 206 276 9538 www.materialpractice.com ISSUED FOR: PERMIT DRAWINGS PERMIT CORRECTIONS ISSUE DATE: CV O CV CO W CC D W cn IDw z zC° LLB rte. _ C LLJ J rn O 10036 EXIST CHIT M MEL J. PETERS N STATE OF WASHINGTON PERMIT DRAWINGS A2 ■ 1 GENERAL NOTES 1. THE APPROVED PLANS SHALL NOT BE CHANGED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFFICIAL. THE APPROVED PLANS ARE TO BE ON THE JOB SITE. 2. CONTRACTOR SHALL VERIFY AND CHECK ALL CONDITIONS AND DIMENSIONS AT THE BUILDING AND REPORT ANY INCONSISTENCIES TO THE ARCHITECT. 3. ALL WORK TO MEET LOCAL CODES AND ORDINANCES. 4. ALL NAILING SHALL COMPLY WITH THE NAILING SCHEDULE OF THE IRC. 5. COMPLIANCE CARD TO BE POSTED VERIFYING INSULATION INSTALLED IN WALLS, CEILINGS, AND FLOORS. 6. PROVIDE METAL NAIL STOPPERS TO COVER HOLES IN STUDS WHERE NAILS COULD PUNCTURE PLUMBING. 7. MAINTAIN 3" MINIMUM CLEARANCE BETWEEN CEILING FIXTURES AND INSULATION. 8. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED, DECAY RESISTANT, OR TWO LAYER OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN WOOD AND CONCRETE OR MASONRY. 9. CONTRACTOR DESIGNED ELECTRICAL. SUBMIT FOR PERMIT AS REQUIRED. 10. CONTRACTOR DESIGNED HVAC. SUBMIT FOR PERMIT AS REQUIRED. 11. PROVIDE SAFETY GLAZING PER SRC R308.4. 12. SERVICE WATER PIPES TO BE INSULATED TO MIN. R -8 IN UNHEATED SPACES. 13. BATT INSULATION SHALL HAVE ALL TEARS AND JOINTS SEALED WITH TAPE. 14. ALL OPENINGS TO BE CAULKED, SEALED, OR W EATH ERSTRIPPED. 15. BATHROOMS AND LAUNDRY ROOMS SHALL BE PROVIDED WITH 50 CFM FAN CONNECTED DIRECTLY TO THE OUTSIDE. KITCHEN SHALL BE PROVIDED WITH 100 CFM FAN CONNECTED DIRECTLY TO THE OUTSIDE. ENERGY CODE NOTES CLIMATE ZONE 1, KING COUNTY PRESCRIPTIVE OPTION III: UNLIMITED GLAZING AREA VERTICAL GLAZING U- FACTOR: 0.30 OVERHEAD GLAZING U- FACTOR: 0.50 DOOR U- FACTOR: 0.20 INSULATION REQUIREMENTS: CEILING: R -49 OR R -38 ADVANCED FRAMING VAULTED CEILING: R -38 WALL ABOVE GRADE: R -21 (R -10 @ HEADERS) WALL BELOW GRADE: R -10 (EXT.) R -21 (INT.) FLOOR OVER UNHEATED SPACE: R -30 SLAB ON GRADE: R -10, 24" WIDTH MINIMUM 50% OF ALL INTERIOR LUMINARIES SHALL BE HIGH EFFICACY LUMINAIRES. ALL EXTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES. PROJECT DESCRIPTION THIS PROJECT CONSISTS OF A 753 SF SECOND STORY ADDITION AND 318 SF GARAGE ADDITION TO AN EXISTING SINGLE FAMILY RESIDENCE. DEMO EXISTING ROOF, FRAME NEW FLOOR, WALLS AND ROOF. NEW HABITABLE SPACES INCLUDE: THREE BEDROOMS, ONE BATHROOM, AND LIVING ROOM. PROJECT DATA OWNER: PROJECT ADDRESS: PARCEL NO: ZONE: OCCUPANCY: CONSTRUCTION TYPE: BUILDING CODE: BUILDING AREAS MAIN FLOOR (EXISTING): SECOND FLOOR (NEW): GARAGE (NEW): SITE AREA: LOT COVERAGE: JOSUE BARDALES 10216 BEACON AVE SOUTH SEATTLE, WA 98178 6810600030 LDR R -3 V -B 2009 INTERNATIONAL RESIDENTIAL CODE 753 SF EXISTING 753 SF NEW 318 SF NEW +/- 7257 SF 1311/7257 =18% LEGAL DESCRIPTION PIPERS P A 1ST ADD DRAWING INDEX A1.1 GENERAL NOTES, VICINITY MAP, SITE PLAN A2.1 FLOOR PLANS A2.2 FRAMING PLANS A2.3 FRAMING PLANS A3.1 EXTERIOR ELEVATIONS A4.1 SECTIONS A6.1 DETAILS A6.2 DETAILS ROOF VENTILATION 1. PROVIDE ROOF : NNNTILATION AT A RATE OF 1:300, W/ 1 PERM VAPOR BARRIER ON WARM SIDE OF INSULATION. 2. PROVIDE RIDGE VENT WHERE RIDGE OCCURS. ROOF VENTING CALCULATIONS: 753 SF ROOF AREA 1/300 REQUIRED VENTING 753/300 = 2.51 SF = 361 SQUARE INCHES REQUIRED PROVIDE MIN. 361 SQUARE INCHES NET ROOF VENTILATION FIRE PROTECTION 1. PROVIDE FIRE BLOCKING PER SRC R602.8. 2. PROVIDE SMOKE DETECTOR SYSTEM POWERED BY 110 VOLT AC WITH BATTERY BACKUP. SMOKE DETECTORS TO BE INTERCONNECTED ON ALL FLOORS. SMOKE DETECTORS TO BE LOCATED IN EACH BEDROOM AND IN CLOSE PROXIMITY TO BEDROOMS IN ACCORDANCE WITH THE SRC. VICINITY MAP N.T.S. NORTH BEACON AVENUE SOUTH 0 20' -0" FRONT SETBACK 15' -0" DECK FRONT SETBACK rn CO aL Q \. co ifP GARAGE ADDITION NEW EXISTING ONE STORY SINGLE FAMILY RESIDENCE - NEW SECOND STORY ADDITION SITE PLAN SCALE: 1/8" = 1' -0" 133, co I \ P•nt \ \ EXISTING DECK NO WORK PLANNING APPROVED • No changes can be made. to these plans without approval from the Planning Division of DCD Approved By: Date :, I , S 112,3„ • E PERMIT U r;..: ED FOR: ensexhanical of Tulavea meson REVISIONS t nh nfm,R shall he made to the scope ?r W tit without prior approval of a. a 't `ila Building Division. . r+Z.V;;V:ZIA4 via require a Herr plan sabm !?al gizq WWI addlional plan ream fees: 1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1g2012 kT ( A City of Tukwila BUILDING DIVISION FILE COPY Permit No. plan review approval is sum to errors and omissions. ., t 'iia! of construction documents does not auth^r!e 1h c 1a ±ion of any adopted code or ordinance. Receipt of approved Reid Copy and conditions is ac lowledgdi: tie; % ; City Of 1Ukwila BUILDING DIVISION RECttvt CITY OF TUIMLA FEB 2 9 2012 PERMIT CENTER 3220 Material First www.materialpractice.com Practice Suite 400 WA 98122 206 276 9538 D Ave South, Seattle, •0 W z W 0 r� V ) C O I- CE W IDw zi 0 0) U) O Ca 10036 STATE EGIST CHIT HAUL PETERS N OF WASHINGTON --_W PERMIT DRAWINGS Al .1 LEGEND NEW STUD WALL -2x4 @ 16" O.C. (INTERIOR) -2x6 @ 16" O.C. (EXTERIOR) EXISTING WALL TO REMAIN EXISTING WALL TO BE DEMOLISHED LINE OF CONSTRUCTION ABOVE OR HIDDEN FROM VIEW SECTION / PAGE NUMBER REFERENCE FLOOR PLAN NOTES: 1. VERIFY ALL EXISTING DIMENSIONS, INCLUDING WALL LOCATIONS, WALL HEIGHTS, WINDOW SIZES, AND DOOR SIZES. 2. WINDOW SIZES INDICATED ARE ROUGH OPENING. 3. DOOR, SIZES INDICATED ARE SLAB, NOT ROUGH OPENING. 4. ALL NEW EXTERIOR WALLS TO BE 2x6 @ 16" O.C. WITH R -21 INSULATION, EXCEPT GARAGE WALLS. 5. INTERIOR PARTITIONS TO BE 2x4 @ 16" O.C. 6. PROVIDE SMOKE DETECTORS IN ALL BEDROOMS. 7. EGRESS WINDOWS TO HAVE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING AREA OF 5 SF, MIN. CLEAR OPENING HEIGHT OF 24 ", AND MIN. CLEAR OPENING WIDTH OF 20 ". EGRESS WINDOWS TO HAVE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING REA OF`* F, MIN. CLEAR OPENING HEIGHT OF 24 ", AND MIN. CLEAR OPENING WIDTH OF 20 ". io Co GARAGE ROOF BELOW 24' -0" 4' -6" 3' -0" 9' -0" EGRESS WINDOWS TO HAVE MAX. SILL HEIGHT OF 44 ", MIN. CLEAR OPENING AREA OF 5.7 SF, MIN. CLEAR OPENING HEIGHT OF 24 ", AND MIN. CLEAR OPENING WIDTH OF 20 ". 3' -0" 4' -6" M • } E 41 U-1 MIN. 36" GUARDRAIL, PROVIDE 1.5" DIA. HANDRAIL 2868 12' -4" 10' -4" in 5' -0" LIVING AREA •ROVIDE MINI ) 22 30" ATTIC '\ ,,, cc ss _1(1 BATHROOM 246 2868 0 .-PROVIDE (1) CARBON MONOXIDE DETECTOR JLST ) OUTSIDE THE BEDROOMS 1 ON EACH FLOOR ALL WINDOWS AND GLASS IN BATHROOMS TO BE LAMINATED OR TEMPERED SAFETY GLAZING PER IRC R308.4 BELOW SD 2668 BEDROOM LL o M ; BEDROOM 12' -4" 10'-0" 9' -9" 2' -10" 4' -5" dr VERIFY i 26' -0" 3' -0" 6' -0" VERIFY NEW UPPER FLOOR PLAN SCALE: 1/4" = 1' -0" NORTH 24' -0" 0 O 0 w Q Q O x 0 NEW GARAGE ADDITION SLOPE CONCRETE SLAB TOWARDS GARAGE DOOR TO PROMOTE DRAINAGE R @ 7.75" 14 T @ 10 00 W zcn -I NEW STAIR H —H II REMODELED KITCHEN LJ zP g a I 0 L— r w a w 0 Q 2 a w w z LIVING AREA 00 00 I-I — — — I' O z 1- X w z 1- X w DEMO WALLS 7 PROVIDE (1) CARBON () MONOXIDE DETECTOR JUST OUTSIDE THE BEDROOMS ) '\ _ON EACH FLOOR �' BEDROOM MODIFIED CLOSET u EXISTING MAIN FLOOR PLAN EXISTING SCALE: 1/4" = NORTH PROVIDE MIN. 24 "x24" CRAWLSPACE ACCESS CORRECTION !TR # 1 , REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1A 2012 City of Tukwila BUILDING DIVISION RECEfVEu CITY OF TUKWILA APR 2 4 2012 PERMIT CENTER V 12- cx,L4 3220 Material First www.materialpractice.com Practice Suite 400 WA 98122 206 276 9538 D Ave South, Seattle, Cf) Z C) 0 p w p 0 Z CC 0 I-- 17-- w 0 CC 0 I- LL' D CC CC (1) u) o_ o Iii ~Q 0 w - w O N_ o N /D N N LLI 0 z w C:I UpJ W CE D 0 W c) IDw z W zco _ N.... O W Cr) 10036 EMT , + CHl1' ' «� fill HQEL J. PETER + N STATE OF WASHINGTON t PERMIT DRAWINGS A2.1 GENERAL STRUCTURAL NOTES: DESIGN VALUES: 1. RESIDENTIAL FLOOR LIVE LOAD: 40 PSF 2. SNOW LOAD = 25 PSF 3. SOIL BEARING PRESSURE: 1500 PSF ASSUMED FOUNDATION NOTES: 1. NEW FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED SOIL. 2. MIN. CONCRETE STRENGTH: 2500 PSI 3. FOOTINGS TO BE PLACED MIN. 18" BELOW GRADE. 4. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, fy= 60,000 PSI. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185, LAP MIN. 8 ". 6. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS, LAP CORNER BARS 24" MINIMUM. 7. CONCRETE COVER FOR REINFORCING SHALL BE 3" WHEN CAST AGAINST EARTH AND 1.5" WHEN CAST AGAINST FORMED SURFACES. WOOD FRAMING NOTES: 1. JOISTS: HEM -FIR #2 OR BETTER 2. BEAMS: DOUGLAS FIR -LARCH #1 OR BETTER, GLULAM BEAMS PER AITC STANDARDS 3. POSTS: DOUGLAS FIR -LARCH #2 OR BETTER 4. STUDS, PLATS, AND OTHER FRAMING: DOUGLAS FIR -LARCH OR HEM -FIR #2 PLYWOOD: 1. ROOF SHEATHING SHALL BE 1/2" WITH SPAN RATING 32/16 2. FLOOR SHEATHING SHALL BE 3/4" WITH SPAN RATING 48/24 3. WALL SHEATHING SHALL BE 1/2" WITH SPAN RATING24 /0 WALL FRAMING: 1. ALL BEARING WALLS SHALL HAVE 2x6 STUDS SPACED 16" O.C. 2. PROVIDE MIN. TWO STUDS AT ENDS OF ALL WALLS, OPENINGS, HEADERS, BEAMS. 3. TYPICAL HEADER SHALL BE TWO 2x8's, UNLESS OTHERWISE NOTED. 4. SOLID BLOCKING SHALL BE PROVIDED FOR ALL POSTS AND COLUMNS THROUGH FLOOR TO SUPPORT BELOW. 5. PROVIDE MID HEIGHT SOLID 2x BLOCKING FOR ALL WALLS OVER 10' -0" IN HEIGHT. 6. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d AT 12" 0.C. AND LAP MINIMUM 4' -0" AT JOINTS AND PROVIDE EIGHT 16d NAILS AT 4" O.C. EACH SIDE OF JOINT. FLOOR AND ROOF FRAMING: 1. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. 2. TOENAIL JOISTS TO SUPPORT WITH TWO 16d NAILS. 3. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS. 4. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH TWO ROWS 16d AT 12" O.C. 5. PLYWOOD FLOOR AND ROOF SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS. 6. PROVIDE APPROVED PLYWOOD EDGE CLIPS AT UNBLOCKED ROOF SHEATHING EDGES, T &G SHEATHING, OR 2x LAID FLAT. 7. ALL FLOOR SHEATHING EDGES TO HAVE APPROVED T &G JOINTS OR SHALL BE SUPPORTED BY SOLID BLOCKING. 8. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SF;EA Fd ifN�. - N/ 9. TOENAIL BLOCKING TO SUPPORTS WITH 16d AT 12" O.C. 10. PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE "NATIONAL DESIGN STANDARD FOR METAL PLATE- CONNECTED WOOD TRUSS CONSTRUCTION, ANSI /TPI 1" BY THE TRUSS PLATE INSTITUTE FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS: TOP CHORD LIVE LOAD TOP CHORD DEAD LOAD BOTTOM HORDL OAD LOAD WIND UPLIFT (TOP CHORD) BOTTOM CHORD LIVE LOAD 25 PSF (ROOF) 8 PSF 5 PSF 38 PSF (ROOF) PER ASCE 7 -05 NO BOTTOM CHORD LIVE LOAD CONSIDERATION NECESSARY FOR THE SCISSORS TRUSSES PARTICULAR TO THIS PROJECT (NO CLEARANCE) WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANG NAIL OR EQUAL). SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS TO THE ARCHITECT & STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BE SIGNED AND STAMPED BY A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON PROVIDE FOR SHAPES, BEARING POINTS, INTERSECTIONS, HIPS, VALLEYS, ETC, SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HP, VALLEY, & INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES, STEP -DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE MANUFACTURER, UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS -TO -TRUSS AND TRUSS -TO- GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING. NAILING REQUIREMENTS, PER 2009 IRC TABLE R602.3 ROOF 1. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL: 3 -8d 2. CEILING JOISTS TO PLATE, TOE NAIL: 3 -8d 3. CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS, FACE NAIL: 3 -10d 4. COLLAR TIE RAFTER, FACE NAIL: 3 -10d 5. RAFTER TO PLATE, TOE NAIL: 2 -16d 6. ROOF RAFTERS TO RIDGE, VALLEY, OR HIP RAFTERS, TOE NAIL: 4 -16d, FACE NAIL: 3 -16d WALL 7. BUILT UP CORNER STUDS: 10d @ 24" O.C. 8. BUILT UP HEADER, TWO PIECES WITH 1/2" SPACER: 16d @ 16" O.C. ALONG EACH EDGE 9. CONTINUED HEADER, TWO PIECES: 16d @ 16" O.C. ALONG EACH EDGE 10. CONTINUOUS HEADER TO STUD, TOE NAIL: 4 -8d 11. DOUBLE STUDS, FACE NAIL: 10d @ 24" O.C. 12. DOUBLE TOP PLATES, FACE NAIL: 10d @ 24" O.C. 13. DOUBLE TOP PLATES, MINIMUM 24" OFFSET OF END JOINTS, FACE NAIL IN LAPPED AREA: 8 -16d 14. SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL: 16d @ 16" O.C. 15. SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS: 3 -16d @ 16" O.C. 16. STUD TO SOLE PLATE, TOE NAIL: 3 -8d OR 2 -16d 17. TOP OR SOLE PLATE TO STUD, END NAIL: 2 -16d 18. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL: 2 -10d 19 -22. NOT USED FLOOR 23. JOIST TO SILL OR GIRDER, TOE NAIL: 3 -8d 24 -25. NOT USED 26. RIM JOIST TO TOP PLATE, TOE NAIL (ROOF APPLICATIONS ALSO): 8d © 6" O.C. 27. NOT USED 28. BUILT UP GIRDERS AND BEAMS, 2x LUMBER LAYERS: 10d, NAIL EACH LAYER @ 32" O.C. TOP AND BOTTOM, STAGGERED, TWO NAILS AT ENDS AND AT EACH SPLICE 29. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS: 3 -16d AT EACH JOIST OR RAFTER SUBFLOOR, WALL, AND ROOF SHEATHING 30. NOT USED 31/32N.-5-/i'6-"4 "'SHEATHING: FLOOR: 8d @ 6" O.C. PANEL EDGES, 8d @ 12" O.C. INTERMEDIATE SUPPORTS. ROOF: 8d @ 6" O.C. PANEL EDGES, 8d @ 12" O.C. INTERMEDIATE SUPPORTS. WALL: 8d @ 6" O.C. PANEL EDGES, 8d @ 12" O.C. INTERMEDIATE SUPPORTS; BLOCK w/ 2x LAID FLAT AT ALL UNSUPPORTED WALL EDGES NEW UPPER FLOOR WALL SHEAR WALL & EXIST. MAIN FLOOR WALL LATERAL REQUIREMENTS 33. NEW WALLS SHALL BE NAILED PER NOTE 31/ 32 ABOVE (8d @ 6 "O.C. EDGES, 12 "O.C. FIELD w/ 2x LAID FLAT AT ALL UNSUPPORTED EDGES). 34. PROVIDE A35 FRAMING CLIPS @ 24 "OC FROM NEW RIM JOISTS TO NEW TOP PLATE (UPPER FLOOR WALL) & EXIST. TOP PLATE (MAIN FLOOR WALL). ALTERNATIVELY, THE EXTERIOR PLYWOOD CAN EXTEND OVER THE RIM JOISTS w/ EDGE NAILING APPLIED IN LIEU OF THE A35 REQUIREMENT. 35. THE EXISTING MAIN FLOOR WALLS ARE ADEQUATE FOR THE SUPPORT OF THE NEW UPPER FLOOR ADDITION. IF NEW SHEATHING IS APPLIED, CONSTRUCT PER THE NEW WALL REQUIREMENTS ABOVE. 36. THE NEW WALL FRAMING AT THE GARAGE SPACE SHOULD BE CONNECTED TO THE FOUNDATION s •- - N . •• •• ••• •M •. • .• Ju PLATE W GHER8. • I'F,4.9.EARE SET PRIOR w/ A P.T. 2x6 SILL PLATE w/ $ • N •• a TO THE CONCRETE POUR, EMBED 7" MIN. IF THE A.B.'s ARE INSTALLED POST CONCRETE POUR, PROVIDE EXPAN. BOLTS, TITEN HD ANCHORS, OR EPDXY EMBEDDED THREADED RODS (ALL w/ 4" MIN. EMBED). IF EPDXY IS UTILIZED IT MUST BE SIMPSON 'SET' HIGH STRENGTH FOR THE LATERAL SUPPORT REQUIREMENTS. • • • •• • N •• ••• N •M •• •• • •• • •• • • M• •»••»N!N••NM•••»N•••N»•NM 37. AT THE BASE OF ALL EXIST. MAIN FLOOR WALLS CONFIRM - z •• IF THERE ARE NO EXIST. A.B.'s EMBED NEW 8•• •• •• •- •• • • • • • FAP FOUNDATION PLATES CAN BE USED IN LIEU OF A.B.'s. THE FOUNDATION PLATE OPTIONS MUST BE INSTALLED @ 72"0C MAX. SPACING AROUND THE PERIMETER OF THE EXIST. FOUNDATION. FOR 1 BOTH PLATE OPTIONS, EMBED 2•• •• •• • • •• • • • ••• 3+ EMBED ONTO FAGE OF EXIST. FOUNDATION. i EXISTING FOUNDATION NEW 6" CONCRETE STEM WALL ANCHOR BOLTS: PROVIDEMIN. $•• » • ' " "' " » "' " "' WITHIN 12" FROM THE END OF EACH PLATE. MINIMUM 7" EMBEDMENT. PROVIDE 1/4 "x3 "x3" WASHERS AND NUT AT EACH ANCHOR BOLT. ALTERNATIVE A.B. OPTIONS PER NOTE 37. CONFIRM (E) FTG IS 16" WIDTH, \. 1 ELSE PROVIDg NEW 24 "x24 "x10" CONCRETE FOOTING W/ (2) #4'S •,\ EA WAY BOTTOM BELOW NORTH ( END OF GLB d' FROM ABV NEW 18 "x18 "x10" CONCRETE FOOTING W/ (2) #4'S EA WAY BOTTOM, TYP. (2) LOCATIONS P.T. 4x4 POST W/ SIMPSON POST BASE, TYP. NEW 18 "x18 "x10" CONCRETE FOOTING W/ (2) #4'S EA WAY BOTTOM, TYP. (2) LOCATIONS P.T. 4x4 POST W/ SIMPSON POST BASE, TYP. EXISTING FOUNDATION x x H d NEW 18 "x18 "x10" CONCRETE FOOTING W/ (2) #4'S EA WAY BOTTOM, PROVIDE SIMPSON POST BASE n LEXISTING FLOOR FRAMING, UNCHANGED i NEW 24 "x24 "x10" CONCRETE FOOTING W/ (2) #4'S EA WAY BOTTOM, PROVIDE SIMPSON POST BASE [:-3 Material Practice 3220 First Ave South, Suite 400 Seattle, WA 98122 206 276 9538 www.materialpractice.com ISSUED FOR: PERMIT DRAWINGS PERMIT CORRECTIONS ISSUE DATE: N N CO N N O N N NEW 6" STEM WALL REINFORCED w/ #4's @ 18 "OC EACH WAY CENTERED IN WALL OVER 12 "x8" CONCRETE FOOTING W/ (2) #4 REBAR LONG. PROVIDE #4 BENT BAR w/ STANDARD HOOK TO MATCH VERTCAL STEM WALL REINFORCING NEW 4" SLAB ON GRADE W/ 6x6 WWM OVER 10 MIL VAPOR BARRIER OVER COMPACTED FILL DOWEL NEW FOUNDATION TO EXISTING W/ #4 REINF. BARS x 30" MIN. w/ 4" EPDXY EMBED; #4'S TO MATCH HORIZ. REINF. FROM NEW FOUNDATION TO THE NORTH EXISTING FOUNDATION 0 w O z Y = U U w zz cn Q w u_ NORTH FOUNDATION / FLOOR FRAMING PLAN SCALE: 1/4" = 1' -0" 11_40 REVIE1NED FOR CODE COMPLIANCE N APPROVED MAY 1 fi 2012 City of Tukwila BUILDING DIVISION RECEVkk�� CITY QF TIUKWILA APR 242012 PERMIT CENTER w U z w CD CC D w 0 � w zLLJ z� w ><cO <ZO) z °g o ww OcD-J � w N W CO ° 1 EG1ST I PRCHIT `! M HAEL J: PETERS + N STATE OF WASHINGTON PERMIT DRAWINGS A2.2 P.T. 4x4 POST W/ SIMPSON POST BASE AND CAP, TYP. CO U) M �- Oz ZI W J ~ u w 0 u_ < U W 00 (2) 2x8 HEADER, TYP. U.N.O. I l alb DOUBLE H ADERS AND STRI i GERS @ STAIR OP NING SI SON HU210 -2 AT EACH DOUBLE JO ST, TYP. 2x10 HF #2 @ 16" o. N 2 J 0 63/4'x18" DOUG J d CC LL Z U Q 0E- FLOOR DIAPHR.. GM 3/4" T &G PLYWOOD: 8d @ 6" O.C. P • NEL EDGES, 8d @ 2" O.C. INTERMEDIAT SUPPORTS FLOOR DIAPHRAGM 3/4" T &G PLYWOOD: 8d @ 6" O.C. PANEL EDGES, 8d @ 12" O.C. INTERMEDIATE SUPPORTS 2x10 HF#2 @ 16" o. j �.... HU610 UPPER FLOOR FRAMING PLAN NEW RAFTER LENGTH EXTENTS FOR 12 "0.C. & 24 "O.C. SPACING THE 13' -6" LENGTH LIMIT FOR 24"0.C. IS BASED ON THE HORIZONTAL PLAN LENG T i 1 AND NOT THE ACTUAL CUT PER THE SLOPE FOR CONSTRUCITCrN NEW ROOF LEDGER 2x10 LEDGER w/ (3) 4•• •• • ,kt MIN! LENGTH SDS SCREWS @ 16 "OC - CENTER INTO EACH STUD PROVIDE 2x FLAT BLOCKING BETWEEN STUDS & (1) 16d NAIL @ 6 "OC NEW WALL SHEATHING 1/2" 24/0 PLYWOOD: 8d @ 6" O.C. PANEL EDGES 8d @ 12" O.C. INTERMEDIATE SUPPORTS PROVIDE 2x BLOCKING AT UNSUPPORTED PANEL EDGES ISTING HEADER, TYP. NORTH SCALE: 1/4" = 1' -0" SIMPSON H2.5 @ EA TRUSS SIMPSON PC CAP, TYP P.T.4x8 ' 0 N O 0 z Q 2 W u- I- • O .T. 4x8 j; GARAGE ROOF BELOW (2) 2x6 HEADER, TYP. U.N.O. 1 u/\ ROOF DIAPHRAGM 1/2" 32/16 T &G PLYWOOD: 8d @ 6" O.C. PANEL EDGES, 8d @ 12" O.C. INTERMEDIATE SUPPORTS PRE ENGINEERED SCISSOR TRUSSES @ 24" O.C. r_ ROOF DIAPHRAGM 1/2" 22/16 T &G PLYWOOD: 8d @ 6" O.C. PANEL EDGES, 2" O� INTERMEDIATE E SUPPORTS NORTH ROOF FRAMING PLAN � 1 SCALE: 1/4" = 1' -0" Material Practice 3220 First Ave South, Suite 400 Seattle, WA 98122 206 276 9538 www.materialpractice.com ISSUED FOR: PERMIT DRAWINGS PERMIT CORRECTIONS ISSUE DATE: N T 0 N co N N N 0 N N WALL SHEATHING 1/2" PLYWOOD: 8d @ 6" O.C. PANEL EDGES 8d @ 12" O.C. INTERMEDIATE SUPPORTS PROVIDE 2x BLOCKING AT UNSUPPORTED PANEL EDGES SIMPSON H2.5 @ EA TRUSS, TYP. ROOF TRUSSES NEW ROOF TRUSSES @ 24 "OC w/ DESIGN REQUIREMENTS PER NOTE 10 OF FLOOR & ROOF NOTES ON SHEET A2.2 TYP. BEARING WALL (BOLD) 2x6 STUDS @ 16" O.C. REVIEWED FOR 'CODE COMPLIANCE APPROVED MAY 1 2012 City of Tukwila BUILDING DIVISION R Cklvtu CITY OF TUK MLA APR 2 4 2012 PERMIT CENTER M HAEL J. PETERSSN STATE OF WASHINGTON PERMIT DRAWINGS A2.3 NEW TOP PLATE NEW 2ND FLOOR 4:12 NEW 36" GUARDRAIL, MAX. 4" OPENING 5:12 2' -0" %— jr1'-6" EXIST. 1ST FLOOR SAFETY GLAZING MATCH WINDOW BELOW 68 ETY ' G EGRESS WINDOW MATCH WINDOW BELOW 2' -0" SAFETY GLAZING REPLACE EXISTING i WINDOW 10'x7' GARAGE DOOR MIME MIME XISTING EXISTING NEW ROOF NEW BEVELED SIDING, 4 " EXPOSURE EXISTING GRADE, UNCHANGED NEW TOP PLATE 9 co Z 0 F- O O NEW 2ND FLOOR w 2' -0" EXIST. 1ST FLOOR WEST ELEVATION SCALE: 1/4" = 1' -0" NORTH ELEVATION SCALE: 1/4" = 1' -0" NEW ROOF NEW 36" GUARDRAIL, MAX. 4" OPENING NEW BEVELED SIDING, 4 " EXPOSURE EXISTING GRADE, UNCHANGED NEW TOP PLATE NEW 2ND FLOOR EXIST. 1ST FLOOR NEW TOP PLATE 00 O ao NEW 2ND FLOOR EXIST. 1ST FLOOR J Ii OW BELOW EXISTING EXISTING 2' -0" SOUTH ELEVATION SCALE: 1/4" = 1' -0" 2' -0" 2' -0" EXISTING EXISTING EXISTING EAST ELEVATION SCALE: 1/4" = 1' -0" 172TO(DL1 REVIEWED FOR APPROVED NCE MAY 1 a 2012 City of Tukwila BUILDING DIVISION R CtIVu CITY F TULA APR 2 4 2012 PERMIT CENTER 3220 Material First www.materialpractice.com D Practice Ave South, Suite 400 Seattle, WA 98122 206 276 9538 = C O 0 z W O V J CC W TJw zi D O CI) w U LLI ) O W 10636 HAEL STATE EAST CHIT 1. PETERS N OF WASHINGTON PERMIT DRAWINGS A3.1 ROOF ASSEMBLY -COMP SHINGLES -15 LB ASPHALT FELT -1/2" PLYWOOD SHEATHING -2x10 RAFTERS @ 16" O.C. -5/8" GWB - PRIMER AND PAINT NEW EAVE RAFTER SISTERED TO 2x10 RAFTER SCREENED VENT 2.5 TIE @ EA RAFTER J WALL ASSEMBLY -LAP SIDING - BUILDING PAPER -1/2" PLYWOOD SHEATHING -2x6 STUDS @ 16" O.C. -R -21 INSULATION -1/2" GWB - PRIMER AND PAINT WALL SHEATHING 1/2" PLYWOOD: 6d @ 6" O.C. PANEL EDGES, 6d @ 12" O.C. INTERMEDIATE SUPPORTS. PROVIDE 2x BLOCKING AT UNSUPPORTED PANEL EDGES 4" CONCRETE SLAB ON GRADE W/ 6x6 WWM OVER VAPOR BARRIER OVER COMPACTED GRAVEL 2x6 P.T. SILL PLATE W/ Y2' A.B. @ 6' O.C., (1) BOLT WITHIN 12" OF EA. PLATE END, MIN 7" EMBED. PROVIDE 3 "x3 "xYa" PLATE WASHERS (1) #4 HORIZ. @ TOP OF WALL GRADE #4 @ 48" O.C. VERTICAL, TIED TO FOOTING BAR (2) #4's 3" CLR 4" PERFORATED FOOTING DRAIN WITH FILTER FABRIC SLEEVE IN GRANULAR FILL MIN 2500 PSI CONCRETE GARAGE WALL SECTION SCALE: 3/4" = 1' -0" ROOF ASSEMBLY - COMP SHINGLES -ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL -MIN. 1" VENTILATION SPACE -ROOF TRUSSES @ 24" O.C. - INSULATION BAFFLE -R -49 INSULATION - 5/8" GWB - PRIMER AND PAINT DRILLED VENT HOLES FLASH ROOF EDGE METAL GUTTER 2x FASCIA NEW SECOND FLOOR WALL ASSEMBLY -LAP SIDING - BUILDING PAPER - SHEATHING PER STRUCTURAL -2x6 STUDS @ 16" O.C. -R -21 INSULATION -5/8" TYPE X GWB - PRIMER AND PAINT FLOOR ASSEMBLY - FINISH FLOORING - SUBFLOOR PER STRUCTURAL -FLOOR JOISTS PER STRUCTURAL -2x6 PLATE - EXISTING CEILING JOISTS - EXISTING CEILING FINISH HOUSE WALL SECTION SCALE: 1/2" = 1' -0" EXISTING MAIN FLOOR WALL EXISTING GRADE EXISTING FOUNDATION ROOF ASSEMBLY -COMP SHINGLES -ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL - 2x10's @ 24" O.C. -5/8" TYPE X GWB - PRIMER AND PAINT ROOF ASSEMBLY -COMP SHINGLES - ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL -PRE ENGINEERED TRUSSES @ 24" O.C. -R -49 BATT INSULATION -5/8" GWB - PRIMER AND PAINT RIDGE VENT WALL ASSEMBLY -LAP SIDING - BUILDING PAPER - SHEATHING PER STRUCTURAL -2x6 STUDS @ 16" O.C. -R -21 INSULATION -5/8" GWB - PRIMER AND PAINT FLOOR ASSEMBLY -WOOD FLOORING - SUBFLOOR PER STRUCTURAL -FLOOR JOISTS PER STRUCTURAL EXISTING FIRST FLOOR WALL EXISTING FLOOR NEW SECOND FLOOR 9 Co EXISTING FIRST FLOOR co EXISTING FOUNDATION ROOF ASSEMBLY -COMP SHINGLES -ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL -PRE ENGINEERED TRUSSES @ 24" O.C. -R -49 BATT INSULATION SECTION LOOKING NORTH 1/4"=1'-0" ROOF ASSEMBLY -COMP SHINGLES -ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL -PRE ENGINEERED TRUSSES @ 24" O.C. -R -49 BATT INSULATION -5/8" GWB - PRIMER AND PAINT WALL ASSEMBLY - LAP SIDING - BUILDING PAPER - SHEATHING PER STRUCTURAL -2x6 STUDS @ 16" O.C. -R -21 INSULATION -5/8" GWB - PRIMER AND PAINT FLOOR ASSEMBLY - FINISH FLOORING - SUBFLOOR PER STRUCTURAL - FLOOR JOISTS PER STRUCTURAL EXISTING FIRST FLOOR WALL EXISTING FLOOR EXISTING FOUNDATION ROOF ASSEMBLY -COMP SHINGLES -ROOF UNDERLAYMENT - SHEATHING PER STRUCTURAL -PRE ENGINEERED TRUSSES @ 24" O.C. -R -49 BATT INSULATION -5/8" GWB _PRIMER ANIl PAINT -aio vVVD ivi Material 3220 Practice Suite 400 WA 98122 206 276 9538 First www.materialpractice.com D Ave South, Seattle, CE 0 LL 0 LU D Cl) 0 Z_ a i 0 F- cc W a_ uJ - PRIMER AND PAINT Q 0 N p REVIEWED FOR H3E COMPLIANCE APPROVED MAY 1 i 2012 City of Tukwila BUILDING DIVISION ... N co NEW SECOND FLOOR - N U) N WALL ASSEMBLY WALL ASSEMBLY -LAP SIDING - BUILDING PAPER - SHEATHING PER STRUCTURAL -R -21 INSULATION -5/8" GWB - PRIMER AND PAINT L1 1 -LAP SIDING - BUILDING PAPER - SHEATHING PER STRUCTURAL -2x6 STUDS @ 16" O.C. -R -21 INSULATION -5/8" GWB - PRIMER AND PAINT COV W CC 0 W 0) IDw Z� W z� w N FLOOR ASSEMBLY O EXISTING FIRST FLOOR CCf) - FINISH FLOORING - SUBFLOOR PER STRUCTURAL -FLOOR JOISTS PER STRUCTURAL NEW GARAGE CHIT HA EL J. PETER N STATE OF WASHINGTON t EXISTING FIRST FLOOR WALL WALL DRAWINGS A4 • 1 EXISTING FIRST FLOOR EXISTING FLOOR r , r'-rIkIf' x111 IARI A TI('lnl EXISTING FLOOR EXISTING FOUNDATION SECTION LOOKING EAST 1/4"=1'-0" REUtivtu CITY OF TUKWILA FEB 2 9 2012 PERMIT CENTER ivi Material 3220 Practice Suite 400 WA 98122 206 276 9538 First www.materialpractice.com D Ave South, Seattle, CE 0 LL 0 LU D Cl) 0 Z_ a i 0 F- cc W a_ uJ Q 0 N p W D N co CI) N U) N 0 z L1 1 O COV W CC 0 W 0) IDw Z� W z� w N O CO CCf) 10036GiST CHIT HA EL J. PETER N STATE OF WASHINGTON t PERMIT DRAWINGS A4 • 1 STEP 1: FACTORY CORNER FLASHING STEP 2: VYCOR TABS STEP 8: VAPROSHIELD JAMB FLASHING STEP 3: SILL FLASHING CUT AND WRAP SILL W/ VAPROSHIELD STEP 9: VAPROSHIELD HEAD FLASHING STEP 4: VYCOR JAMB FLASHING STEP 5: INSTALL WINDOW W/ CAULK ON FLANGE STEP 6: METAL HEAD FLASHING STEP 7: VYCOR HEAD STEP 10: UNDER SILL FLASHING STEP 11: BUILDING PAPER WRAP BUILDING PAPER UNDER SILL AND JAMB FLASHING WINDOW FLASHING NOT TO SCALE (2) SIMPSON HD3B W/ 5/8" ALLTHREAD @ EACH END OF DECK INSULATION FLASHING WOOD TRIM, PAINTED WINDOW PER SCHEDULE WINDOW HEAD DETAIL A6.1 / SCALE: 1" = 1' -0" �2 WINDOW PER SCHEDULE 3/4" WOOD STOOL AND APRON, PAINTED WOOD TRIM, PAINTED LAP SIDING, 4" EXPOSURE R -21 INSULATION WINDOW SILL DETAIL A6.1 FLASHING OVER LEDGER 2x PT JOIST WITH SIMPSON LU HANGER SCALE: 1" = 1' -0" - 2x8 P.T. HEM -FIR LEDGER W/ 2'x4" GALVANIZED , LAG BOLTS @ 24" O.C. STAGGERED AT 2" FROM TOP AND BOTTOM OF LEDGER, AND PLACED BETWEEN 2" AND 5" IN FROM THE ENDS GRADE 0 o. d X31 DECK CONSTRUCTION A6.1 SCALE: 1" = 1' -0" 4x4 POST PER PLAN DECKING PT BEAM PER PLAN SIMPSON LU HANGER SIMPSON HUC BEAM HANGER @ POST SIMPSON ABU POST BASE W/ 5/8" ANCHOR BOLT 10" SQ. CONCRETE PLINTH - REINFORCE W/ (4) #4 VERT & #3 HORIZ @ 6" O.C. CONCRETE FOOTING W/ (2) #4's EA WAY REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 t 2012 City of Tukwila BUILDING DIVISION R ktvkZ CITY TU KWILA APR 2 4 2012 PERMIT CENTER Material Practice 3220 First Ave South, Suite 400 Seattle, WA 98122 206 276 9538 www.materialpractice.com ISSUED FOR: PERMIT DRAWINGS PERMIT CORRECTIONS ISSUE DATE: O N co N_ O (.1 N 4 10036 EGIST� t' �i�CHIT� MTtHAEL .: PETERS ► N STATE OF WASHINGTON PERMIT DRAWINGS A6.1 ROOF SHEATHING PER PLAN FULL DEPTH 2x BLOCKING (MAY BE DRILLED FOR VENTING) w/ 8d @ 6 "OC FASCIA PER ARCH SHEARWALL PER PLAN PRE -MFRD TRUSS PER PLAN (FLAT BTTM OR SCISSOR AT OWNERS OPTION) H1 AT EACH TRUSS HEADER / BEAM PER PLAN EXTERIOR WALL @ EAVE SCALE: 1" = 1' -0" 16d @ 6 "OC FULL DEPTH BLKG (MAY BE DRILLED FOR VENTING) .*.DRILLED Scvs K FASCIA PER ARCH PER ARCH SHEARWALL PER PLAN RAFTER PER PLAN, SLOPE VARIES PER ARCH H2.5 TIE AT EA RAFTER A35 PER PER SW SCHED @ 24" OC MAX HDR PER PLAN WHERE OCCURS EXTERIOR BEARING WALL STICK FRAMED SCALE: 1" = 1' -0" 1' -6" MAX PER ARCH 2x4 BLKG w/ (2)16d THRU TRUSS TOP CHORD EA END ROOF SHEATHING PER PLAN 8d @ 6 "OC 2x4 OUTRIGGERS LAID FLAT @ 24 "OC (5)8d -- -- --III �- -- -i- /- /- -- -- - -- --� ■ � ■--■ • • IN • • ••■■� ��� I� �I�- -- --- IV ji (2)16d AT EA iii 1 NOTCH TO LET OUTRIGGER OUTRIGGER 1 THRU 1 1 11 FASCIA PER ARCH (6)16d THRU BLOCK INTO BRACE A34 (BRA CE TO TOP PL) PRE - MANUFACTURED TRUSSES PER PLAN 2x4 ((2) 2x4 WHERE LENGTH EXCEEDS 6' -0 ") BRACE @ 8' -0 "OC MAX NAIL (2) 2x4 w/ 16d © 12 "OC GABLE END TRUSS SHEATHED TO MATCH SHEARWALL BELOW EXTERIOR GABLE END TRUSS SCALE: 1" = 1' -0" (8)16d @ 4" OC AT EACH SIDE OF SPLICES, TYP JIMMIINMMINIMM ■i ■i■i ■iii ■i■ilr 16d @ 12" OC STAGGERED ELSEWHERE TOP CHORD SPLICE BOTTOM CHORD SPLICE 6' -0" MIN BETWEEN SPLICES SPLICES TO OCCUR @ CL OF VERT STUD TYP TYPICAL TOP PLATE SPLICE SCALE: 1" = 1' -0" 2x6 CONT (2) 16d @ EA TRUSS TOP CHORD TRUSS PER PLAN OVER FRAMING CONNECTION SCALE: 1" = 1' -0" JOISTS AND SHEATHING PER PLAN BEAM PER PLAN LUS SERIES HANGER D\2;---0(04 CS16 x 30" w/ (24) 8d EVENLY SPACED SEE BELOW FOR ADDT'L REQMT's 1' -3" 1' -3" ili uIiI,i11Ii iIi iii• FLUSH BEAM OR HEADER PER PLAN AT FLUSH BEAM OR HEADER TYP DOUBLE TOP PLATE PER DETAIL 3/S4.0 (6) 16d EACH END A35 @ EXT WALLS ONLY OMIT @ HEADERS < 6' -0" MULTI -STUD PER PLAN NAILING PER GENERAL NOTES 1\ TYPICAL HEADER SUPPORT BEAM OR HEADER PER PLAN REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 g 2012 City of Tukwila BUILDING DIVISION WHERE OPENING IS LESS THAN 4' -0 ", PROVIDE (1) BEARING STUD, UNO SCALE: 1" = 1' -0" 1) ---- 0(.01,1 RtUtivtw CITY OF TUKWILA FEB 2 9 2012 PERMIT CENTER VD Material Practice 3220 First Ave South, Suite 400 Seattle, WA 98122 206 276 9538 www.materialpractice.com O o W Cf) 0 z 0 cc cc W uJ Q N 0 o W N 0 N Cn N (3 z O (1) W 1 CE D 0 W c) D z� W W z00 U..1 O co Q) 10036 EGIST CHIT M HAEL ,i. PETERS N STATE OF WASHINGTON - ----.. PERMIT DRAWINGS A6 . 2