Loading...
HomeMy WebLinkAboutPermit D12-075 - HUCK MARK - OFFICEMARK HUCK DC 7100 FUN CENTER WY SUITE 120 D12-075 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: Project Name: MARK HUCK DC DEVELOPMENT PERMIT Permit Number: D12 -075 Issue Date: 04/17/2012 Permit Expires On: 10/14/2012 Owner: Name: H2 OFFICE LLC Address: 7100 FUN CENTER WAY STE 100 , TUKWILA WA 98188 Contact Person: Name: THOMAS LI Address: 16022 12 AV SW , BURIEN WA 98166 Contractor: Name: ADEK CONSTRUCTION COMPANY Address: 23423 14 AV S , DES MOINES WA 98198 Contractor License No: ADEKCCC887C7 Lender: Name: Address: Phone: 206 - 295 -3409 Phone: 206 - 412 -1475 Expiration Date: 02/27/2014 DESCRIPTION OF WORK: NEW TENANT: OFFICE SPACE - WALLS - LIGHTS Value of Construction: $20,000.00 Fees Collected: $779.67 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -075 Printed: 04 -17 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: C Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this peT►it does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the prf6rmance of wgrk. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 1 t J 1 � I Date: 1 r Print Name: Ck 4A) PAAA This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -075 Printed: 04 -17 -2012 7: All construction shall be done in conform with the approved plans and the requireme of the International Buildin g Code or International Residential International Mechanical Code, Washingto to Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) doc: IBC -7/10 D12 -075 Printed: 04 -17 -2012 26: Aisles leading to required exits shall b4Ikvided from all portions of the building and t`equired width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 30: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 33: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 34: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 35: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 37: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 012 -075 Printed: 04 -17 -2012 CITY OF TUKTVIA Community Develop! Prt Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Peet No. Project No. P- `02-3 Date Application Accepted: �- 2 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION _ King Co Assessor's Tax No.: Z`f 2 3 " D Cf B -- 921 Site Address: 1-I 00 h.r n <<n-I1r Way - IzQ Suite Number: I La Floor: New Tenant: ❑ Yes ❑..No Tenant Name: Mar IC NV C iC p L . PROPER OWN R Name: 50T7 14 u lviS,l II'G- gide L 5Y j j Name: G0 Tl pl 2 1`t; .e City: -U 1_ State: Address: 7)oo Fvn (errhr Wet/ lip City: .1v -�i let State: (A.44 Zip: C►(� 1 96 CONTACT PERSON - perso vmg all, prof ct communication (Jjr7 L i Name: 50T7 14 u lviS,l II'G- gide Address: 7100 Funcerr L'r W4 City: -U 1_ State: � Zip: i8,8 r..0 w ill Phone: rj ac3: L534ax: 20 L - 5 -u 8 Email: 1 LL ` OC h.l w i sh ABU I • Con-■ GENERAL CONTRACTOR INFORMATION Company Name: vn Corm v Company Name: Address: Architect Name: U L; City: State: Zip: Phone: Fax: City: State: wA Uurie► -∎ Contr Reg No.: Exp Date: Phone: 2oS, _ Zct5.34 ?Fax: zo Tukwila Business License No.: Email: 2- 1.3 - ° U i1. — ,.....c. e t r i FJ n rr,o r i- H:Wpplications\Forms- Applications On Line ‘2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh ARCHITECT OF RECORD Company Name: -1-701,-.. L' Company Name: Address: IL o Z Z 12.44` ,4Jt & J Architect Name: U L; Phone:ZS3 _5 3 -BSOO Fax: Address: 1(Oo z I z-1 1, me sty �0 City: State: wA Uurie► -∎ Zip: 784,6 CJ Phone: 2oS, _ Zct5.34 ?Fax: zo Email: 2- 1.3 - ° U i1. — ,.....c. e t r i FJ n rr,o r i- ■01"1 ENGINEER OF RECORD Company Name: -1-701,-.. L' Engineer Name: V ri, f i Address: IL o Z Z 12.44` ,4Jt & J City: gam; e.t--/ State: tAifret Zip: ? Q� t 4 ? O Phone:ZS3 _5 3 -BSOO Fax: ...r-kovb,c S Li kozzo 1 pia,. 1 -60r -, LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: mGfk 140c.k (self') Address: I Cl ?,_ c, )c, 7 v.\ 54_ City: ri Q State:a/4 Zip: ?sS i c Page 1 of 4 BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid pr $ 2l 000 4/_ Describe the pe of work (please rovide detai information): 0 i�t S �. 04115 L h-3 ExistingWlding Valuation: $ rr -p4/ -24W Will there be new rack storage? ❑ ....Yes *No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forn s- Applications On Line 12012 Applications J'ermit Application Revised - 2- 7- I2.docx Revised: February 2012 bh Page 2 of 4 Existing Remodel Interior Remodel Addition to Existing Structu a New Type of Construction per IBC Type of Occupancy per IBC 1�` Floor 1Z5'0 I%�/ 2 1) .15 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forn s- Applications On Line 12012 Applications J'ermit Application Revised - 2- 7- I2.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1 R Signature: A ORIZED AGENT 4� Print Day Telephone: Date: '3- 9 -1 Mailing Address. t►I _ fit H:Wpplications\Forms- Applications On Line\2012 Applications'Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh City State Zip Page 4 of 4 V� PUBLIC WORKS PERMIT INF TION — 206 - 433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ... Highline ❑...Valley View ❑ ... Renton ❑ ...Sewer Availability Provided 0... Renton ❑... Seattle Se atic System: On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards O ... Geotechnical Report O ... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis El.. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑... Storm Drainage ❑ .. Sanitary Side Sewer 0... Abandon Septic Tank ❑... Grease Interceptor ❑ .. Cap or Remove Utilities 0... Curb Cut ❑... Channelization ❑ .. Frontage Improvements 0... Pavement Cut 0... Trench Excavation ❑ .. Traffic Control 0... Looped Fire Line 0... Utility Undergrounding ❑ .. Backflow Prevention - Fire Protection Irrigation " Domestic Water ❑ .. Permanent Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Water Only Meter Size 11 WO # ❑ .. Deduct Water Meter Size " ❑ .. Sewer Main Extension Public ❑ Private ❑ ❑ .. Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\ApplicationslForms- Applications On Line12012 Applications\Permit Application Revised - 2- 7- 12.docx Revised, February 2012 bh Page 3 of 4 • City of Tukwila Q ~ • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 �s� 2 Phone: 206-431-3670 Fax: 206 - 431 -3665 I908 °` Web site: http: / /www.TukwilaWA.gov Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: Applicant: MARK HUCK DC RECEIPT Permit Number: D12 -075 Status: APPROVED Applied Date: 03/09/2012 Issue Date: Receipt No.: R12 -01352 Initials: User ID: Payee: WER 1655 Payment Amount: $474.30 Payment Date: 04/17/2012 04:23 PM Balance: $0.00 QUANG BUI TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1329 474.30 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 469.80 640.237.114 4.50 Total: $474.30 doc: Receiot -06 Printed: 04 -17 -2012 dl City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.Tukwila WA.gov Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: Applicant: MARK HUCK DC RECEIPT Permit Number: D12 -075 Status: APPROVED Applied Date: 03/09/2012 Issue Date: Receipt No.: R12 -00997 Initials: User ID: WER 1655 Payment Amount: $305.37 Payment Date: 03/09/2012 09:53 AM Balance: $474.30 Payee: MARK HUCK TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04427G ACCOUNT ITEM LIST: Description 305.37 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 305.37 Total: $305.37 doc: Receipt -06 Printed: 04 -03 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ti? (206) 431 -36 . Permit Inspection Request Line (206) 431 -2451 Project: t'1r1 eN R 4. t''` LtC. -L� (t Type of Inspection: r I Ni-A Address: • "_t 06 r-11 C'1 -4G 42 lLCt D to Called: r AA's " CO iE4 I Y Q A l Special Instructions: '� lnl iti- T 59Ace 6 er� ;.ec :c� e r ? 'OM U.Pa-1 b Date Wanted:. `es 3U- iZ_ a.m. C`p `_ Requester: Phone No: az ,-- Li 12 -- i LI 7 • • Npproved per applicable codes. aCorrections required prior to approval. COMMENTS: r AA's " CO iE4 I Y Q A l O60ltPAkleni .. A.pp f ?.1 r Ins pector:"\ ❑ Datg;_ ION FEE REQ IRED. Pridr to next inspection. fee must be 00 Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPE aid at !rl • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -3670 .Permit.Inspection Request Line (206) 431 -2451 INSP ECTION NO.1 ' PERMIT NO. Project: wiy4K /- ( .fie Type of Inspection: f- i ?,7,Pi G Address: 'WOO /.:'/n/ (1FA,Oi Q (&! Date Called: 'Date _.y Special Instructions: • J'9& . C) 5537vr Wanted:. .5— - /7 t`;. P.m. Requester: 67e3 Phone No: 02a6-4/12 - /'V7 S Approved per applicable codes. Corrections required prior to approval. COMMENTS: .49 SPECTION FEE R P UIRED. Pri fr to next inspection. fee must be at 6300 Southcente Blvd.. Suit 100. Call to schedule reinspection. - .�. � � 5 a INSPECTION NO. INSPECTION RECORD Retain a copy with permit ID/2-1075 PERMIT NO. CITY.OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Ot� Project:. • 12V1 gX / /i /[ .< , Type of Inspection: /:-/?„9,/4/4... Date Called: Address: ?/6l r f/ / /FN7ir e. 4' Special Instructions :. ' • • Date Wanted:. .5 -2 -'2 a.m Requester: Phone No: a6,6 — y.2. i~lv7°5 • Approved per applicable codes. a'Correction s required prior to approval... COMMENTS: i- A. Nif (r, teti NIL, S — f171 wR 10i + l s Ins E or: Date: 5-� )7 EINSPECTION FEE R UIRED. Prig to next inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • , � • ' a INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 0/2_ - /2 —S 4,57 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: 04. rv) /4 2 X 1-i• er ' i Type of Inspection: S_r.. 1-r a. ea...c a_ / f".....,... 1 Address: 7100 Ca 4 L Suite #: of)'`'''''' a.Y Contact Person: Special Instructions: Phone No.: HA;proved per applicable codes. Corrections required prior to approval. COMMENTS: fni,S"3.c, Date: s/Z 9112- Sprinklers: Fire Alarm: f Hood & Duct: p,d -t,, C (...4.41-4-1.- •1 `, S,,v�..- ,/C /..�. -. C € __ R . .� �r ' . :Occupancy Type: 4/ •1. N. % .. ._..P..-.... j# -- - - .e.,,... -n'.' ' r \.. _ I. ... s- Needs Shift Inspection: fni,S"3.c, Date: s/Z 9112- Sprinklers: Fire Alarm: f Hood & Duct: Monitor: •1 `, Pre -Fire: Permits: .� �r ' . :Occupancy Type: Inspector: fni,S"3.c, Date: s/Z 9112- Hrs.: / rg $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential terior Lighting Summary LTG -INT 200' Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Info �/ / rI Project Address Date A. i t �7 �\ - -+A► L / i1. OM( G-f/ For Build g�epartment Use F �� ccop,y Watts Proposed Applicant ame: - Applicant Address: Applicant Phone: Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts er ft2 '• Gross Interior Area in ft2 Allowed x Area Watts Proposed :. F-r- I \GYi of pr.= ems.. o Are ----is--- r _ 9 2/, 7 c -7, ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts /47 21 Provosed Lighting Wattage Location (floor plan /room #) Fi Description Number of Fixtures Watts/ Fixture Watts Proposed F-r- I \GYi of 9 s ----is--- CGL- oT�f�- , _ 9 2/, 7 c -7, ��-- REVIEWED FOR CODE COMPUANCE APPROVED APR 0 3 2012 City of Tukwila Total Pry lice i4�tit t l Allowed Watts for Interior Total Proposed Watts 3 a Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, Tamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED MAR 09 2012 PERMITCENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised November 2010 Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage ® Other Qualification Cheskt Note: If occupanc type isf'tther" andfixture answers s het e , the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (SeetiOI 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic "dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. ABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /fe) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail1 °, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply, In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. f >9(1 ! J 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above42 feet; •,; , I 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. • 5) Watts per square foot of room may be increased by'2% per foot of ceiling height above 9 feett • � 6) Reserved. f! i 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lightine;ovrer+Allowarn"�ce of 1,11w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, :the Unit Lighting Power Allowance for the court area is 2.60 W /fte. f 10) Display window illumination installed within 2 feet of the window, provided that the displaS4WindO7W js':sepa%ated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting forjfyee- standing dil play1w t re'the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled,-separately from the general lighting, to be tumed off during nonbusiness hours7This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) t'ERMiI CO PLAN REVIE • TING SLIP ACTIVITY NUMBER: D12 -075 DATE: 03 -09 -12 PROJECT NAME: MARK HUCK DC SITE ADDRESS: 7100 FUN CENTER WY - SUITE 120 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: �uil ing Dlvi ion N 03 '11 Works (/0 re Prevention Structural Panning Ivisio n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03-13 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 04-10-12 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • Page 1 of 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ADEK CONSTRUCTION COMPANY UBI No. 601463902 Phone 2064121475 Status Active Address 23423 14Th Ave S License No. ADEKCCC887C7 Suite /Apt. License Type Construction Contractor City Des Moines Effective Date 2/27/2012 State WA Expiration Date 2/27/2014 Zip 98198 Suspend Date County King Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status INCOLL'904NR INCO LLC Construction Contractor General Unused 8/19/2010 8/19/2012 Active JAMESCH987D7 JAMES & CO HARDWOOD FLOOR Construction Contractor General Unused 3/27/2002 3/27/2004 Archived ADEKCCC953N9 ADEK CONSTRUCTION COMPANY Construction Contractor General Unused 8/29/2005 1/27/2012 Expired Business Owner Information Name Role Effective Date Expiration Date BUI, QUANG THANH Owner 02/27/2012 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Navigators Ins Co 46BCO23965 02/27/2012 Until Cancelled $12,000.00 02/27/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 Contractors Bonding & Insuranc C12SG2912 02/02/2012 02/02/2013 $1,000,000.00 02/27/2012 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 04/17/2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2009 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D12 -075 Occupant/Tenant: MARK HUCK DC Building Address: 7100 FUN CENTER WY, Suite No. 120 Parcel No.: 2423049092 Property Owner: H2 OFFICE LLC 7100 FUN CENTER WAY STE 100 , TUKWILA WA 98188 Use: CHIROPRACTIC OFFICE Occupancy Group/Division: B Type of Construction: V -B Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: BUILDING OFFICIAL 13 a0 r�2oiZ D AT THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES AREA TO BE REMODELED FUN CENTER WAY SITE. PLAN SCALE 1" = 80' -0" a r r,. aua�c'E K i G LOCATION MAP • s t! .0 it C 121'.19 . •g • ,a, $ .ode ,:r,;.:.!rgr:'.;:.a.r:.. :;,,..snot, ;v r= {,:, • SITE LOCATION • • GYPSUM WALL SECTION SCALE: NTS. METAL DECK MAX. 1 IN 6 PLUMB 12 GAUGE VERTICAL. WIRE @ MAX. OF 4' -0" O.C. & 8" FROM EDGE. MAX. SLOPE OF 1 HORIZONTAL TO 6 VERTICAL(MIN). STABILIZER BARS CO PERIMETER AVY DUTY MAIN OR CROSS RUNNER POP RIVETS @ TWO ADJACENT PERIMETER SIDES (SEE TYPICAL PLAN) 2" PERIMETER MOLDING 12 GAUGE VERTICAL HANGER WIRE @ 4' -O" O.C.' SECURED TO METAL DECK SEE T -BAR CEILING PLAN FOR LOCATIONS) RAYMOND SPRING STRUT OR EQUIVALENT WITH MIN. •CAPACITY OF 1000 Lbs C/W CUSTOM BOTTOM & TOP CONNECTION FIXTURES AS PER MANUFACTURER SPECIFICATIONS 10 GAUGE SPLAY WIRES SECURED TO METAL -DECK @45' HEAVY DUTY CROSS TEE HEAVY DUTY MAIN TEE SPLAY BRACING DETAIL SCALE: NTS. CEILING DETAILS NTS NORTH 9, -3" 9' -6" 14' 30" C FILE ROOM 8' RECEPTION AREA 1 \ \ \ ADJUSTMENT ROOM #1 SPINAL STRETCH OFFICE SEE THRU WINDOW (2'X18 ") 2X4 ACOUSTICAL SUSPENDED CEILINGS (10' AFF TYP,) ---\ ADJUSTMENT ROOM #2 MASSAGE ROOM #2 10 %6" \\\ r!o LUNCH ROOM of REST ROOM (EXISTING) 12 15' -6" ROOM SCHEDULE NAME FLOOR Entrance/ painted walkway concrete Massage carpet Room #1 Lunch room painted Concrete The rest of carpet rooms WALL GWB wall painted GWB wall painted GWB wall painted GWB wall *Rest room vinyl tiles GWB wall painted * - -- Existing CEILING Opening ceiling Suspended acoustical ceiling (10' AFF) Opening ceiling Opening ceiling Suspended acoustic panels (8' AFF) DOOR SCHEDULE TAG SIZE MATERIAL FRAME FINISH REMARKS A* 3'X6' -8" Glass Steel Glass * *Panic hardware Notes- 1,5,6,7,12 B 3'x6' -8" wood . wood paint Level privacy pass Utility hard - wares /notes -1,2,4 C 3'x6' -8" wood wood paint Solid wood door /notes 1,2,3 * This door shall have sign that reads " this door to remain unlocked during the business hours or occupancy hours" Panic hardware: Von Duprin -22 RIM -22E0 3628 * ** Door a & Door B are existing. ** Hardware Notes: 1. Hinges 5. Overhead concealed closer 9. 18"x24" 2. Surf. Mounted closer 6.90 degree hold open 3. Door stop 7. Reinforced strike @ dead bolt 10. 10" kick plate 4. Seals 8. Under cut door 1/2" for venting 11. Peep hole 12. Sign over door to read "this door shall remain unlocked during business hours or occupant hours" louvered vent LEGEND EXISTING WALL NEW GWB WALL EXISTING WINDOW------ - EMRGENCY/ EXIT LIT--- - REST ROOM FAN FIRE EXTINGUISHER PLANNING APPROVED No ohatvjes can be made to these plans without approval from the Planting Division of DCD Approved By: Date: VII 48' -9" \I\ 11' 44_ MASSAGE ROOM #1 FLOOR PLAN . ROOF (TYP.) oh ---- EXISTING \ ROOF STRUCTUR REVIEWED FOR CODE COMPLIANC APPROVED APR 0 3 2012 ONI/- City of u ita BUILDING VISIO GWB WALL (5/8 "X 4'W) ATTACHED TO METAL STEEL STUDS, FLOOR & DECK TRACK W /1" LONG, TYPES SELF - TAPPING STEEL SCREWS SPACED 7" OC ALONG EDGES OF BOARD & 12" OC IN THE FIELD OF THE BOARD. (JOIN TAPE & COMPOUND VINYL, DRY OR PREMIXED JOIN COMPOUND APPLIED IN TWO COATS TO JOINS AND SCREW HEADS, PAPER TAPE 2" WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINS. FLOOR RUNNER 25GA (MIN.) GALV. STEEL SECURE NAIL DRIVE ANCHORES (11/2" MIN.) TO CONCRETE FLOOR @ 16" OC CONCRETE FLOOR (EXISTING) NOTES 1. THE CONSTRUCTION OF THIS PROJECT SHALL COMPLY WITH CHAPTER23 SISMIC PROVISION OF THE 2009 IBC 2. THE CONTRACTOR MUST VERIFY THE DIMENSION OF ALL THE EQUIPMENTS, AND BUILDING. 3. EXTRA WALL PROTECTION IS REQUIRED ON WALLS BEHIND SINKS, EQUIPMENT LIST 1. RECEPTION COUNTER (3'WX3'H) FORMICA TOP 2. FILE CABINET 3. OFFICE COUNTER (18 "X9'X3'H) FPRMICA TOP 4. EPLOYEE CABINET 5. REFREGERATOR 6. HANK SINK (13 "X17 ") 7. ELECTRICAL PANEL (EXISTING) SEARS POLARWARE K1734C 200A,120/208V,3PHASE V L 31/2 "W 20GAUGE METAL STUDS @6' O.C. (TYP) FASTEN TO TOP OF WALL OR EXISTING CONSTRUCTION W /2 -10GA SCREWS - CEILING RUNNER 25G (MIN) GAL. STEEL ATTACHED TO EXISTING GWB CEILING /NAIL DRIVE ANCHORES (11/2" MIN) @ 16 "OC EXISTING CEILING (10 "AFF) (IF APPLICABLE) METAL STUDS (2X4) OR 4X6 FOR REST ROOM HANGING FIXTURES, @ 16 "OC BRIDGE @ 1/2 POINT •6" BASE @ BOTH SIDES GWB WALL SECTION NTS CODES IBC 2009 INTERNATIONAL BUILDING CODE IMC 2009 INTERNATIONAL MECHANICAL CODE IFGC 2009 INTERNATIONAL FUEL GAS CODE IPC 2009 INTERNATIONAL PERFORMANCE CODE IEBC 2009 INTERNATIONAL EXISTING BUILDING CODE NFPA -54 -2009 NATIONAL FIRE PROTECTION ASSOCIATION- NATIONAL FUEL CODE NEC 2009 NATIONAL ELECTRICAL CODE UPC 2009 UNIFORM PLUMBING CODE ENERGY- 2009 WASHINGTON STATE ENERGY CODE VIAQ - - - -- 2009 WASHINGTON STATE VENTILATION AND OUT DOOR AIR QUALITY CODE ICC /ANSI A- 117.1 -2003 INTERNATIONAL CODE COUNCIL/ AMERICAN NATIONAL DESIGN INSTITUTE ACCESSIBILITY STANDARD LOCAL CODES - - -THE CITY OF TUKWILA REVISIONS _ No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: and may include additional plan plan submittai fees. SEPARATE PERMIT REQUIRED FOR: O mechanicai !~lead Plumbing Gas Piping City of Tukwila BUILDING DIVISION PROJECT DATA: LEGAL ESCRIPTIO\ PILE COPY Penult Notstawatio Plen review eprowetI$ subjectioasore ands 4pproval of construction documene does no ate-117..,3 the violation of any adopted code or o� r 1': of OJapproved t, and M owe 1 1-42 -42 �t Of 242304 92 PORTION OF W OF SECTION 24- .23 -04 BEGIN INTERSECTION OF 2M LINE OF PRIMARY STATE HIGHWAY NO 1, GREEN RIVER INTERCHANGE UNDER KC SUPERIOR COUR i C;',USF NO 596089 STA POC (2M) 134 +28.56 WITH A -LINE STA POT (A) 102 +82.12 WITH STATE OF WASHINGTON DEPT OF TRANSPORTATION SR 405 GREEN RIVER INTERCHANGE R/W STA 99 +00 TO STA 120 +00 SHEET 2 OF 2 REVISED DECEMBER 31, 1992 TH N 42- 30 -02 E ALONG CA OF SAID A -LINE 88.55 FT TO STA 103 +70.67 OF SAID A -LINE TH N 47 -29 -58 W 60 FT TO POINT ON NLY R/W OF SAID PRIMARY STATE HIGHWAY NO 1 SAID POINT BEING BEGINNING OF CURVE CONCAVE TO SOUTH RADIUS OF 163 FT AND ALSO BEING POINT OF BEGINING TH NLY, ELY & SLY ALONG SAID R/W ON ARC OF SAID CURVE THRU C/A 0 64 -48 -29 t84.37 FT TH LEAVING SAID R/W & BEARING N 21 -14 -41 E 38.16 FT TH N 64 -48 -08 W 5.90 FT TH N 22 -58 -18 W 166.10 FT TH N 22-01-42 E 229.49 FT TO POINT ON ORDINARY HIGH WATER LINE OF GREEN (WHITE) RIVER AS APPEARED N AUGUST 11, 1997 TH ALONG ORDINARY HIGH WATER OF SAID E IVER THE FOLLOWING COURSES AND DISTANCES S 70 -00 -00 W '39.06 FT TH S 73 -00 -00 W 65 FT TH S 67 -00 -00 W 100FT TH S 57 -40 -00 W 30 FT TH 63 -50 -00 W 35 FT TH S 56 -30 -00 W 100 FT TH S 51 -00 -00 W 50 FT TH S 35-40-00 W 40 FT TH S 39 -00 -00 W 60 FT TH S 52 -20 -00 W 50 FT TO NELY R/W FOR 2M -LINE TH SLY ALONG R/W TO ITS INTERSECTION WITH NLY R/W OF SAID A -LINE TH N 42 -30 -02 E 9.42 FT TO POINT OF BEGINING -AKA ADJUSTED PARCEL 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98 -0028 RECORDING NO 9806309017, TI/ BUILDI \G STATISTICS NUMBER OF STORIES : 1 OCCUPANCY CLASSIFICATION B- BUSINESS OCCUPANCY LOAD : 1250 SF /100 SF = 12.5 OCCUPANTS NUMBER OF EXIT REQUIRED : 1 NUMBER OF EXIT PROVIDED : 1 BUILDING TYPE: TYPE -V -B SPRINKLERED AREA OF SPACE TO BE REMODELED: 1250 SF -1 CONSTRUCTION VALUE: $12,500.00 PAR<IC 1 STANDARD -73 _COMPACT - 5 'ACCESSIBLE -4 \FGR v AT!O SPECIAL NOTES, THE GENERAL CONTRACTOR MUST PROVIDE ALL REQUIRED ACCESSIBILITY SIGN REQUIREMENTS FOR THE ENTIRE SPACE SUCH AS RESTROOM, EXIT DOORS, ROOMS ETC. IN ACCORDANCE WITH IBC SECTION 1110 -1. PROJECT DESCRIPTION Tenant Improvement: This is an existing space and shall be converted to a Chiropractic Clinic. The basic existing structures, walls, doors, restroom and the building remains unchanged. Including: 1. Floor plan 2. Electrical plan PR()OCT INFORMATION NAME: WASHINGTON CHIROPRACTIC CLINIC FOOTAGE: ADDRESS: 10 PROP. O NER: 1,250 SF FAMILY FUN CENTER f1700 FUNCENTER WAY, #120 TUKWILA WA 98188 SCOTT HUISH /503- 381 - 9590 /huwishPaol,com 7300 FUN CENTER WAY, TUKWILA WA 98188 TENANT: MARK HUCK /206- 295 -3409 1932 SW 167TH STREET, BURIEN WA 98166 DESIGN . THOMAS LI / JOHN BLACKLAW / 253 -973 -8500 ENGINEER: 16022 12 TH AVE., SW BURIEN WA 98166 OCCUPANCY CLASSIFICATION: B BUSINESS CONTRUCTION TYPE: V -B SPRINKLERED ZONING C /LI- COMMERCIAL LIGHT INDUSTRIES PARCEL NUMBER: 2423 -0490 -9201 CONTRACTOR: TO BE DECIDED LATER LEGAL DESCRIPTION: SEE ABOVE ON THIS DRAWING RECEIVED INDEX F} 1 -- -FLOOR PLAN 1 - -2 - -- ELECTRICAL PLAN MAR 09 2012 PERMIT CENTER bPO73 CONSULTANT THOMAS LI crs O O z E- U G.1.1 0 DESCRiPTflN w 'FLOOR PLAN WC -1 3 -9 -12