HomeMy WebLinkAboutPermit D12-085 - WESTFIELD SOUTHCENTER MALL - GHOST ARMOR - KIOSKGHOST ARMOR
2800 SOUThCENTER MALL
K -0859
D12 -085
City oPi'ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 9202470010
Address: 2800 SOUTHCENTER MALL TUKW
Suite No:
Project Name: GHOST ARMOR
Permit Number: D12-085
Issue Date: 04/26/2012
Permit Expires On: 10/23/2012
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: VINH TRAN
Address: 952 E BASELINE RD, SUITE 106 , MESA AZ 85204
Contractor:
Name: J E M CONSTRUCTION INC
Address: 29506 8TH AVE S , ROY, WA 98580
Contractor License No: JEMCOI *033DD
Lender:
Name:
Address:
Phone: 480 - 208 -3100
Phone: 253 843 -2765
Expiration Date: 05/15/2013
DESCRIPTION OF WORK:
INSTALLATION OF KIOSK FOR THE SALE OF ELECTRONIC SCREEN AND BACK PROTECTORS
Value of Construction: $25,000.00 Fees Collected: $937.25
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: II-B Occupancy per IBC: 0019
Electrical Service Provided by: PUGET SOUND ENERGY
* *continued on next page **
doc: IBC -7/10
D12 -085 Printed: 04 -26 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
• •
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: - )-6 IN
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: .n.�� i1n X �—-ti Date: 4 f 2(n f i 2_
Print Name: �} l tt•)\ p�� L-L r✓1�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
doc: IBC -7110
D12 -085 Printed: 04 -26 -2012
shall not be valid. The issuance of a permit l d on construction documents and other data 11 not prevent the
Building Official from requiring the correctiW errors in the construction documents and data.
7: ** *FIRE DEPARTMENT CONDITIONS * **
8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
9: Post address on kiosk per approved Westfield standards.
10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
11: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IBC -7/10
D12 -085 Printed: 04 -26 -2012
Site Address:
Tenant Name:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office "use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's T r
tS ie 7..c800 SoviltCOs�f Li PIA. - ISetcrRE Suite
C2 i- *442440 tz. Mi.
PROPERTY OWNER
Company Name: .6 2. ��. `ax.rk pit,j
Name: WE 'F1Q..n
Name: V t 14 ;
Address: 11(00 1 ski,l c' `ttze 4 ,1U
t'TH Ftcotl-
City: Los "a_vs State: CA
Zip: q:02.c
CONTACT PERSON - person receiving all project
communication
Company Name: .6 2. ��. `ax.rk pit,j
Address: ` \(o f `"`A 3D0 c.g.1"-
Name: V t 14 ;
Phone: Cam\ 5 41 bpd Fax: 2Y t etc q 1 le 1
Contr Reg No.: Exp Date:
Tukwila Business License No.:
Address: O 2 e R.A8.eL1 f4 (2.1)
#
\040
Phone: lai G s- 4ubbFax: (60 sue- bS il i to
City:
A State: A
Zip: i�-'2
Phone: 1 bb 20b 30c Fax: t jbo 14,(o 3i5�0'9 0
Email: V144 ,C40s,T- POQ.Cot4
GENERAL CONTRACTOR INFORMATION
Company Name: .6 2. ��. `ax.rk pit,j
Address: ` \(o f `"`A 3D0 c.g.1"-
City :T 1.,pt C liy State: 07 Zip: st I t l is-
Phone: Cam\ 5 41 bpd Fax: 2Y t etc q 1 le 1
Contr Reg No.: Exp Date:
Tukwila Business License No.:
H: \Applications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -11. docx
Revised: August 2011
bh
•
•
New Tenant:
Floor: :48T.
❑ Yes g..No
ARCHITECT OF RECORD
Company Name: . FAe(l`CAT \6,\ 1
�!
Company Name: .Z F'A59-1CAT1(51.1/4.)
Address:
l'i Log- &o.rt 7>o■ V4 A-
Architect Name: -o A O cD0 A L
Phone: ?)0t SOs- i 1 0 Fax: 'ibotO1 sts -- 4 i v
Address:
Q-4- So■Yni 3c>o v.liaST
City: v 1
City: ,1S11" -1-- 1-°' c'*{State: ()T. Zip:
Z
Phone: lai G s- 4ubbFax: (60 sue- bS il i to
Email:
1-0S*1tCa(,e7FA5•C -otA
ENGINEER OF RECORD
Company Name: . FAe(l`CAT \6,\ 1
�!
Engineer Name:,�� � » ,_ ` 1.
`""`�1
Address:
l'i Log- &o.rt 7>o■ V4 A-
City:C, r Lor C 1.1.,,State: `y„r. Zip: pis2D9
Phone: ?)0t SOs- i 1 0 Fax: 'ibotO1 sts -- 4 i v
Email: `e:::¢ -150,) Do tJ C rAe . q 0,4
LENDER/BOND ISSUED (required for' projects $5,000 or
greater per RCW 19.27.095)
Name: (.'' ‘1/4flu`e
e.
Address: -1C2' S 35
't, 1,32"
F-t AF (O co
City: v 1
State: �--.._ Zip: aS
Page 1 of 4
BUILDING PERMIT INFORMATION 206 -431 -3670
Valuation of Project (contractor's bid price): $ d2 ) 00
Describe the scope of work (please provide detailed information):
Existing Building Valuation: $
n18ThLC,FtTt oF y-loSk-- Fla?, S4t, •E-1.,012DKJ l c_
Will there be new rack storage? ❑ Yes
No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes
❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers • Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Saf ty Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: \ApplicationsWorms- Applications On Line \2011 Application\' rmit Application Revised - 8.9 -I l.docx
Revised: August 2011
bh
Page 2 of 4
Existing
' Interior Remodel '
Addition to ..:•.
Existing .
• Structure •
: ' ; ' ` -. ' .•
: i {rs F::
:New -7.
e of'•
�.Constructton;per
, 'IBC •
_ .�'yp'of-'.'
,06alipancy per
:. • IBC '• ;;
1' Floor
X
\410S(2—
Y.\r
rd Floor
3rd Floor
Floors . thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes
❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers • Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Saf ty Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: \ApplicationsWorms- Applications On Line \2011 Application\' rmit Application Revised - 8.9 -I l.docx
Revised: August 2011
bh
Page 2 of 4
• •
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN R OR.'CU'TIIIORIZED AGENT:
Signature: '
Print Name: `V (IsikA t■I
Mailing Address:
H:Wpplications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx
Revised: August 2011
bh
Date:
Day Telephone: L19)0 20% 3 too
City
A•4- el-20(-1
State Zip
Page 4 of 4
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 9202470010 Permit Number: D12-085
Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 03/13/2012
Applicant: GHOST ARMOR Issue Date:
Receipt No.: R12 -01043
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $937.25
Payment Date: 03/13/2012 02:48 PM
Balance: $0.00
GHOST ARMOR LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 8159 937.25
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $937.25
565.30
367.45
4.50
doc: Receiot -06 Printed: 03 -13 -2012
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
612.-66?
Project:
Cast All 61O�
Type of Inspection:.
1:21. IQ A' .
Address:
n% SdW $.11" VA A k'
Date Called:
.
Specia Instructions:
K~ S7
Date Wanted:.
1 Q — 1 "? -.I"
a1rr,,
Requester:
Phone No: •
3 1 0 --q 1c.t -...6007
t
Approved per applicable codes. a.Gnrrections required prior to approval.
COMMENTS:
Inspector.
Dater •
I
REINSPECTION FEE REQUIRED. Prior to next inspectin. ;fee rn
tp ust.be•
paid at 6300 Southcenter Blud.. Suite 100. Call to schedule.reinspection.
•
•
•
•
•
•
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
1)la- o8S
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Project:
��5T
A-ti
Sprinklers:
Type of Inspe n:
. ',ie y J L
Address: al9o0 9. C . vvvvt t--
Suite . #: f<_.... 0 (es---G ' � _
.'' . .
Cog ' i
on:
Special Instructions:
Permits:
Phone No.:
Occupancy Type:
Yt":1--Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
ikl
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
•
Pre -Fire: .
Permits:
Occupancy Type:
Inspector:
ikl
,.., .9-...
Date: 407/ '7// ZHrs.:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State: 1 Zip:
Word /Inspection Record Form.Doc
6/11/10
:!
T.F.D. Form F.P. 113
•
•
09 -04 -2012
•
City of Tukwila
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
VINH TRAN
952 E BASELINE RD, SUITE 106
MESA AZ 85204
RE: Permit No. D12 -085
GHOST ARMOR
2800 SOUTHCENTER MALL TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 10/23/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 10/23/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. D12 -085
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665
• •
OEM- GO COP\
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D12-085 DATE: 03 -13 -12
PROJECT NAME: GHOST ARMOR
SITE ADDRESS: 2800 SOUTHCENTER MALL - K -0859
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
16kJ& i - 1 1)-- vw 1 (, V 1,�. /l%�- S 12
dinc ivlson Fire Prevention Planning Division
N(
u Ic Wo s —
IF Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 03 -15 -12
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route n Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 04 -12 -12
Not Approved (attach comments) ri
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Prer Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name J E M CONSTRUCTION INC UBI No. 601770782
Phone 2538432765 Status Active
Address 29506 8Th Ave S License No. JEMC01'033DD
Suite /Apt. License Type Construction Contractor
City Roy Effective Date 3/4/1997
State WA Expiration Date 5/15/2013
Zip 98580 Suspend Date
County Pierce Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
MILLER, JAMES E
President
01/01/1980
Amount
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
CBIC
SA7695
03/01/2002
Until Cancelled
$12,000.00
03/19/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
13
American
States
Insurance Co
01C12205491
04/16/2011
04/16/2013
$1,000,000.00
04/13/2012
12
AMERICAN
STATES INS CO
01C1220549
04/16/2009
04/16/2011
$1,000,000.00
04/21/2010
11
AMERICAN
STATES INS CO
01C1220549
04/16/2009
04/16/2010
$1,000,000.00
04/17/2009
10
0010 CAS INS
BL053040470
12/02/2008
12/02/2009
$1,000,000.00
11/20/2008
9
OHIO CAS INS
BL00353040470
12/02/2003
12/02/2008
$1,000,000.00
11/27/2007
Summons /Complaint Information
Cause
County
Complaint
Judgment
Status
Payment
Paid By
10 -2- 11928 -6
BROOKDALE LUMBER INC
InterPlead: No
PIERCE
Date: 08/16/2010
Amount: $10,795.92
Bond(s): SA7695
Date:
Amount: $0.00
Dismissed
Date:
Amount:
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip /Print.aspx 04/26/2012
LLEGAL AND SUBJECT TO PROSECUTION
w
KIOSK TENANT IMPROVEMENT FOR
GHOST ARMOR
SOUTHCENTER MALL
2800 SOUTHCENTER MALL, STE. K -0859
TUKWILA, WASHINGTON 98188
SEPARATE PERMIT
REQUIRED FOR:
M
Electrical
Plumbing
City of Tukwila
, BUILDING DIVISION
OWN HP
GHOST ARMOR
952 EAST BASELINE RD.
SUITE 122
MESAS ARIZONA 85204
APCHIT HCT
MICHAEL Co RAYMOND, AIA
PROJECT ARCHITECT.
32 WEST CENTER ST. SUITE 203
PROVOS UTAH 84801
PH. # (801) 374 -2100 FAX # (801) 374 -0100
CODE INFORMATION
OCCUPANCY: M
TYPE CONSTRUCTION (MALL): TYPE IIB
KIOSK ALLOWABLE AREA: 300 S.F.
ACTUAL AREA: 68 S.F. NET AREA
FIRE SPRINKLED: YES
APPLICABLE BUILDING CODES: 2009 IBC,
2009 IEBC, 2009 UPC, 2008 WCEC,
2009 IMC, 2009 WSEC, 2003 ICC /ANSI
INDEX TO DRAWI \GS
ARCHITECTURAL
A -1.1
A-12
A -1.3
A -1.4
TENANT KIOSK FLOOR PLAN & DETAILS
KIOSK DETAILS
KIOSK DETAILS
KIOSK DETAILS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 232012
City of Ia
BUILDIN VISION
FILE COPY
Phr regkra approvel is subject to WON and omlvdons.
Approval of construction documents does not authorize
v;alation of any adopted code or oi nanc e. Receipt
•
412-to I.7_ i t 2,
C'Iht Of 1'is
WILDING DIVISION
9$3a1 °.., $
11
ix
saw
a
rn
Se* SW
VICINITY MAP
NORTH
macy
4 .E
Fl
GHOST ARMOR
SUITE: K -0859
JC:I
R1-1 .-;,
,1.
LOCATIO\ PLAN
- ACRYUC $ACKLI7
rmi' TRANSLUCENT !MITE LASER CtsT
LOGO ON BOTH SIDES OF PYLON
PUSH THROUGM ACRYLIC LETTERING WITH
VINYL BLUE OVERLAY
— TRANSLUCENT VVHITE
ACRYLIC BACKLIT LIGHT FIXTURE
BEHIND CUT OUT
NOTE:
THIS PAGE IS FOR ILLUSTRATION PURPOSES AND IS INTENDED
FOR REFERENCE ONLY•
I YOUR SPECIFIC CONFIGURATION MAY VARY DUE TO VARIABLES
SUCH AS, BUT NOT LIMITED TO:
INSTALLATION REQUIREMENTS. GEOGRAPHIC FEATURES.
TRAFFIC FLOW REQUIREMENTS, SITE SIZE REQUIREMENTS
AND AGREEMENTS .
FOR TENANT APPROVAL BASED UPON AN ACCURATE DEPICTION OF A
SPECIFIC KIOSK:
DOCUMENTS SHOWING THE SITE AND RELATIVE POSITION OF THE
INSTALLATION SHOULD BE OBTAINED AS SOON AS POSSIBLE FROM
THE SITE MANAGER 1 COORDINATOR AND SUPPLIED TO e2 DESIGN
AND FABRICATION FOR PREPARATION OF INSTALLATION DOCUMENTS
AND GRAPHIC REPRESENTATION.
1—
U
0_
W
N
NC. PROVO, UTAH. ALL RIGHTS RESERVED. UNAUTHO
uJ
W
LO
—1
2012 BY RAYMOND, VAN NOSD
1—
U
C : \Userslsanthony\ Desktop \SCR1I1-0VE1- 20120306.dwg, 3/6/2012 9:18:31 AM,
CLEARANCE
PDF
PLA\
Combustible kiosks or other structures shall not be
located within the mall unless constructed of any of the
following materials:
1.4 Fire - retardant- treated wood complying with IBC
Section 2303.2
1.5 Foam plastics having a maximum heat release rate
not greater than 100kW (105 Btu/h) when test in
accordance with the exhibit booth protocol in UL
1975.
Aluminum composite material (ACM) having la flame
spread index of not more than 25 and a smoke -
developed index of not more than 450 when tested
as an assembly in the maximum intended for the
use in accordance with ASTM E 84 or UL 723.
CLO
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOT:: Revisions will require a new plan submittal
1 and may include additional plan review fees. i
61 12"
23 `e/
2U 5dr- - - ? -�'
78'
32 -_ - - --
- 1:1. - - - --
PYLON
«8 112'• -
23 1
23
34•
12112°
REF. DRAWINGS). A2 2 -.
REF DRAWINGS) -A2
REFERENCE DRAWING 42 2 -
r .1.°
1 1420
RENEE DRAWING 2.2 .4
REF DRAVONG:51 A -1
10x10 -2
REF DRA
-- - - -REF DRA
NG5) 2.3
2O95
2
RECEIVED
MAR 13 2012
HERMIT CENTER
REVISIONS
1
BY
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
JOB NO.
12 -001
OF
SHEET
A-1.1
SHEET*
LLEGAL AND SUBJECT TO PROSECUTION
L RIGHTS RESERVED. UNAUTHORIZED REPRODUCTION AN
NC. PROVO, UTA
2012 BY RAYMOND, VAN NOSDOL &
UPPER COUNTER TOPS DuPONT CORIAN COBALT
(OR EQUIV.) SOLID MATERIAL SURFACE
COUNTER TOP
DUPONT CORIAN COBALT
SOLID MATERIAL SURFACE
(OR EQUIV.)
COUNTER TOP
DUPONT CORIAN COBALT
SOLID MATERIAL SURFACE
(OR EQUIV.)
TRASH CUT- OUT -
6" DIAMETER
r 4•r
35 1/2'
20 5/8 " --
11 112''!
12 3/4"
11 1/2"
121/8"
A1.2
21 7/8"
251 /2"
25 1/2"
24 5/8"
75 1/4 "
COUNTER TOP DETAIL
PLAN VIEW
BACKSPLASH "SHIM" LOCATES
BETWEEN STANDARD AND ADA
COUNTER ELEMENTS
DUPONT CORIAN COBALT (OR EQUIV.)
TOE KICK DETAIL
PLAN VIEW
KICK 1 mm METAL - STAINLESS STEEL
OVERF.R. CURED MDF
• INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED
• ALL STUCTURAL CONST. MATLS FIRE RATED
• ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING
• ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED
• ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES.
DRAWER RUNNERS
HAFELE/ACCURIDE #3832 TO HOLD
45.00 KILOGRAMS PER PAIR
BACK PANEL
NOTE' - BuIL0 IN 5 SEPERATE CABINETS
MC THEN ATTACH TOOET/ER
BACK CENTER PANEL --
COUNTER TOP OUTLINE
Al
- 221/2' ••
GARBAGE/
EXTRA STORAGE.
FORMICA CC2 (NEW WHITE) -
ON F.R. MDF.
1 1/2"
- SECTION 1 -1
Al-
-- COUNTER TOP OUTLINE
:TIMBERLINE T101'-
/` (OR EQUIV) LOCK ,
108 " - --
2 DETAIL 2
Al GLASS TRACK DETAILS
REF.ONLY
1
23 1/2 ",
23241/2"
17 174"
TIMBERLINE T101
(OR EQUIV.) LOCK
j.r
OVERLAY DOOR / DRAWER-
LEFT
.SIDE ELEVATION
i 1/2"
r 1
8 BACKLIT LED
GRAPHIC PANEL
24 112'
- FRONT
ELEVATION
33 8/8' --
74'
- 33 5/8" --
SHELVES WITH PINS
ON SIDE WALLS
Ai
- -TOE KICK DETAILS
REF DWG. A1.2
- SLIDING TEMPERED GLASS
DOOR WITH LOCK
RIGHT
SIDE ELEVATION
• INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED
• ALL STUCTURAL CONST. MATLS FIRE RATED
• ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING
• ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED
• ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES.
PYLON ELEMENT RESTS HERE
34"
DRAWER
DRAWER RUNNERS
HAFFI F /ACCURIDE #3832 TO HOLD
45.00 KILOGRAMS PER PAIR
FORMICA CC2 (NEW WHITE)-- -
ON F . MDF.
34"
. 4" -. 24"
8 112" --
10" 123/■"
, f,
3",-
L�
18 314"
GARBAGE
EXTRA STORAGE
10"
COUNTER TOP OUTLINE
SECTION 1 -1
Al
At 5114•'I
3 "-4
74"
108 "__
A.2 3
COUNTER TOP OUTLINE
TIMBERLINE T101
(OR EOUIV) LOCK
A2
2`.DETAIL 2
A2 CLASS DETAILS
REF ONLY
TIMBERLINE T101
(OR EQUIV) LOCK
25" 26 1/2"
17 1/4" '. 17
TIMBERLINE T101
(OR EQUIV.) LOCK
- -LEFT "SIDE ELEVATION
1 1/2"
TO POWER SOURCE
34 1/2" 36"
33 5/8"
BACK
ELEVATION
FRONT
-_ -_. ELEVATION
.........<
..
33 5/8" - -- -
74'...- • - - --
SHELVES WITH PINS `
ON SIDE WALLS
Ire
17•
8' BACKLIT LED
GRAPHIC PANEL
SLIDING TEMPERED GLASS
DOOR WITH LOCK
4
10 1/2"
3/4'
1_,_
PYLON SHELF RESTS ON
BACK PANEL CUTOUT
COUNTER TOP OUTLINE
--TOE KICK DETAILS
REF DWG. A2 2
- RIGHT
`SIDE ELEVATION
• INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED
• ALL STUCTURAL CONST. MATLS FIRE RATED
• ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING
• ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED
• ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES.
61
81"
231/2' --
23 1/2"
•' 6 1/2"'+
4 SHELF DETAIL
PLAN VIEW
231 /2" - -- - -- •6 12" t44
SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
- -- FORMICA CC2 (NEW WHITE)
OVER F.R. CURED MDF
_
4 1/2"
23 1/2'
SHELF DETAIL
FRONT ELEVATION
-3 1/2"
51"
SHELF DETAIL
SIDE ELEVATION
A1.3
31!2° •
I.-
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 3 2012
City of Tukwila
BUILDING DIVISION
P1.- °Ss
RECEIVE('
MAR 13 2012
PERMIT CENTEF
REVISIONS BY
EGISTERED
HITE T
MICH L C. RAYMOND
STATE OF WASHINGTON
Raymond .Van Nosdol & Assoc. Inc
Ray
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
JOB NO.
12 -001
OF
SHEET
A -1.2
SHEET
ILLEGAL AND SUBJECT TO PROSECUTION.
NC. PROVO, UTAH. ALL RIGHTS RESERVED. UNAUTHDRIZED REPRODUCTION AND /OR USE
2012 BY RAYMOND, VAN NOSDOL
37 1 36' 37 1/2"
39 1/2"
32"
20 5/8"
TRASH CUT -OUT
6" DIAMETER
12 1/8"
6"
7 1/2"
-75 114'
1 1/2"
COUNTER TOP DETAIL
PLAN VIEW
TOE KICK DETAIL
PLAN VIEW
8"
HUBERT 8" STAINLESS STEEL
RECEPTACLE LID PT# 41281
SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
KICK 1 mm METAL - STAINLESS STEEL
OVER F.R- CURED MDF
A2.2
REVIEWED FOR
CODE c R VEO CE
APP
CROSS SECTIONS
PYLON SIGN ELEMENT DETAIL -2
6 1/2"
81"
DETAIL -1
A2
23 1/2"
i t
9 1/2"
-.
23 1/2"
a- 61/2 "-.
32"
-SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
PYLON
6 1/2"
A2.4
91/2" ..-
3 1/2"
23 1/2"
FORMICA CC2 (NEW WHITE)
OVER F.R. CURED MDF
=61/2 "+
MAR 2 3 2012
CitiNG DIVISION
1S1CN
CROSS SECTIONS
PYLON SIGN ELEMENT DETAIL -2
r.
1" - 1
C
SLOT FOR REMOVAL OF i -
SIDE ACRYLIC PANEL .:
(PANEL SLIDES UP FOR - - -
REMOVAL)
-x..25
1 /4"d CHANNEL FOR SIDE
ACRYLIC PANEL
HERA T -5 SLIMLITE _
48" (46.75) h
OR EQUIV.
48" {►
ALL BLOCKING OF TO COUNTERTOP =■
KILN DRIED 60" i
F.R. 3/4" MDF
F
{r•
VIZIO M26VP
MONITOR l
i
6"
1 A
18"
"+
12" T
6"
t L__ 1_ -� 1
SECTION 1 -__
NOTE:
INTERNALLY ILLUMINATED PORTION OF THIS FEATURE
1/4" SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT
VINYL FILM: PANTONE 299C2X PROCESS BLUE
3M SCOTCHCAL SERIES 230 FILM
32" "GHOST ARMOR" LOGO LASER CUT
(BOTH SIDES - REVERSE SIDE SHOWN
CUTAWAY VIEW)
a- 6" .".
0-2 "-' +1 /2"
3/4"
u T u:
29 112" ►. ►5 112 " -rt
1 I 1
114" ,. 3" 31/4"
.: 1 i . - i
T /8" , , -- _ --
P- 3/4" WIDE DAIDO 12 3/4 ,.-F
RECESS '.
r ,
27" ±- ' T 2 3/4"
"` i ..m i
'i4 1/2" _ 5/8 .
22 7/$
F
i I ,, .=!,r
44"
2T' -- • i
6" 7 1/2"
t s
20" �- SIDE BLOCKING
FOR
HERA T5 OR EQUIV.
SIGN WHITE ACRYLIC PANEL RECESSED
INTO FRONT AND BACK PYLON
BLOCKING AS REQ'D TO
RETAIN MONITOR
NOTE: BLOCKING
BE REMOVABLE FOR MONITOR
INSTALLATION AND PLACEMENT
FLOATING SHELF TO ACCOMODATE
DIFFERING MONITOR MODELS
UTILIZE SPACER BLOCKS BENEATH
ADJUST HEIGHT
(MONITOR MUST BE 26" DIAG.)
FRONT AND REAR PANELS OF 1/2"
F.R. CURED MDF TO ELIMINATE
ANY AND ALL WARPAGE
LWR. COUNTER TOP
2ND LAYER 3/4" F.R,V MDF FOR BOLT
THROUGH ATTACHMENT
A2.4
i
-
a
c
-
o
c
1/4"
PANELS
MUST
TO
TO HERE 1" �. � ..,.
REF. A2.4b f 6"
j T 1. i
1 1/2"
0- 6" -.4 - -- 1/2" BUILDUP THIS LOCATION CREATES
1" STROKE AROUND ACRYLIC PANEL
�`a TO COUNTER TOP ELEVATION
- '_SECTION 2
MTG PLATE OF 2 LAYERS 3/4" A2
KILN DRIED F.R. MDF TO INSIDE CABINET OUTLET
DETAIL 3
ELECTRICAL COMPONENT DETAILS
1z. __
20A SINGLE POLE SWITCH
}
,
iR1NCTION BOX
POWER SOURCE
36,; MIN EXTENSION
TO MALE GRNDD 20A PLUG
ALL ELECTRICAL COMPONENTS
UL APPROVED
REFERENCE DRAWING El FOR
LAYOUT, ROUTING AND COMPONENT
SPECIFICATIONS
ALL ELECTRICAL COMPONENTS
UL APPROVED
DETAIL 4
LED BACKLIT DOOR PANEL DETAIL
DEDICATED SWITCHED 4 -WAY
FOR LIGHTED ELEMENTS RETAINING
(SCREW
181/4"
l 3/4"
A2.3
FRAME
ATTACH)
PANEL
PANEL
T101
LOCK
EDICATED UNSWITCHED 4 -WAY
FOR POS AND COMPUTER SYSTEMS 1/2"a- .+
► 3" 41
20A SINGLE POLE
BREAKER
T_
CLEARANCE FOR HINGE
AS REQUIRED
_
2" -"a
25"
WIRE TO
TRANSFORMER
s
ELECTRICAL CLEARANCE FOR HINGE
AS REQUIRED
_- _
.:
..
19"
1
17 1/4"
- -___
23 1/8"
19 318"
i
20"
19 3/8" -
181/2"
171/2"
__...
+~
21"
T
► ►. 1 /2"
- 3" -. LEGEND
= LED PANEL
► ■ = DURATRANS GRAPHIC
,. = v4" ACRYLIC
DOOR FRAME
l TIMBERLINE
(OR EQUIV)
21"
INSIDE VIEW
LED BACKLIT DOOR
37 1 36' 37 1/2"
39 1/2"
32"
20 5/8"
TRASH CUT -OUT
6" DIAMETER
12 1/8"
6"
7 1/2"
-75 114'
1 1/2"
COUNTER TOP DETAIL
PLAN VIEW
TOE KICK DETAIL
PLAN VIEW
8"
HUBERT 8" STAINLESS STEEL
RECEPTACLE LID PT# 41281
SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
KICK 1 mm METAL - STAINLESS STEEL
OVER F.R- CURED MDF
A2.2
REVIEWED FOR
CODE c R VEO CE
APP
CROSS SECTIONS
PYLON SIGN ELEMENT DETAIL -2
6 1/2"
81"
DETAIL -1
A2
23 1/2"
i t
9 1/2"
-.
23 1/2"
a- 61/2 "-.
32"
-SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
PYLON
6 1/2"
A2.4
91/2" ..-
3 1/2"
23 1/2"
FORMICA CC2 (NEW WHITE)
OVER F.R. CURED MDF
=61/2 "+
MAR 2 3 2012
CitiNG DIVISION
1S1CN
o ss
RECEIVED
MAR 13 2012
PERMIT CENTEP
4920
GISTERED
IT CT
MICHAEL C. RAYMOND
STATE OF WASHINGTON
TENANT IMPROVEMENT FOR
CID
- SOUTHCENTER
2800 SOUTHCENTER MALL, STE. K -0859
TUKWILA, WASHINGTON 98188
v
Raymond Van Nosdol & Assoc.
(801) 374 -2100
PLANNERS
ARCHITECTS
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
J013 NO.
12 -001
SHEET
A -1.3
OF SHEETS
CROSS SECTIONS
PYLON SIGN ELEMENT DETAIL -2
r.
1" - 1
C
SLOT FOR REMOVAL OF i -
SIDE ACRYLIC PANEL .:
(PANEL SLIDES UP FOR - - -
REMOVAL)
-x..25
1 /4"d CHANNEL FOR SIDE
ACRYLIC PANEL
HERA T -5 SLIMLITE _
48" (46.75) h
OR EQUIV.
48" {►
ALL BLOCKING OF TO COUNTERTOP =■
KILN DRIED 60" i
F.R. 3/4" MDF
F
{r•
VIZIO M26VP
MONITOR l
i
6"
1 A
18"
"+
12" T
6"
t L__ 1_ -� 1
SECTION 1 -__
NOTE:
INTERNALLY ILLUMINATED PORTION OF THIS FEATURE
1/4" SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT
VINYL FILM: PANTONE 299C2X PROCESS BLUE
3M SCOTCHCAL SERIES 230 FILM
32" "GHOST ARMOR" LOGO LASER CUT
(BOTH SIDES - REVERSE SIDE SHOWN
CUTAWAY VIEW)
a- 6" .".
0-2 "-' +1 /2"
3/4"
u T u:
29 112" ►. ►5 112 " -rt
1 I 1
114" ,. 3" 31/4"
.: 1 i . - i
T /8" , , -- _ --
P- 3/4" WIDE DAIDO 12 3/4 ,.-F
RECESS '.
r ,
27" ±- ' T 2 3/4"
"` i ..m i
'i4 1/2" _ 5/8 .
22 7/$
F
i I ,, .=!,r
44"
2T' -- • i
6" 7 1/2"
t s
20" �- SIDE BLOCKING
FOR
HERA T5 OR EQUIV.
SIGN WHITE ACRYLIC PANEL RECESSED
INTO FRONT AND BACK PYLON
BLOCKING AS REQ'D TO
RETAIN MONITOR
NOTE: BLOCKING
BE REMOVABLE FOR MONITOR
INSTALLATION AND PLACEMENT
FLOATING SHELF TO ACCOMODATE
DIFFERING MONITOR MODELS
UTILIZE SPACER BLOCKS BENEATH
ADJUST HEIGHT
(MONITOR MUST BE 26" DIAG.)
FRONT AND REAR PANELS OF 1/2"
F.R. CURED MDF TO ELIMINATE
ANY AND ALL WARPAGE
LWR. COUNTER TOP
2ND LAYER 3/4" F.R,V MDF FOR BOLT
THROUGH ATTACHMENT
A2.4
i
-
a
c
-
o
c
1/4"
PANELS
MUST
TO
TO HERE 1" �. � ..,.
REF. A2.4b f 6"
j T 1. i
1 1/2"
0- 6" -.4 - -- 1/2" BUILDUP THIS LOCATION CREATES
1" STROKE AROUND ACRYLIC PANEL
�`a TO COUNTER TOP ELEVATION
- '_SECTION 2
MTG PLATE OF 2 LAYERS 3/4" A2
KILN DRIED F.R. MDF TO INSIDE CABINET OUTLET
o ss
RECEIVED
MAR 13 2012
PERMIT CENTEP
4920
GISTERED
IT CT
MICHAEL C. RAYMOND
STATE OF WASHINGTON
TENANT IMPROVEMENT FOR
CID
- SOUTHCENTER
2800 SOUTHCENTER MALL, STE. K -0859
TUKWILA, WASHINGTON 98188
v
Raymond Van Nosdol & Assoc.
(801) 374 -2100
PLANNERS
ARCHITECTS
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
J013 NO.
12 -001
SHEET
A -1.3
OF SHEETS
• INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED
• ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING
• ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED
• ALL SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES.
KICK 1 mm THK STAINLESS STEEL
OVER F.R. CURED MDF
42"
1/2° BOLT HOLES FOR PYLON ATTACH.
BOTH SIDES FOR UNIVERSAL FIT
A3 7
CENTER PANEL CUT ours Y
REFERENCE DETAIL 3 -A3 - --
SECTION 2 -2
DRAWER CABINET DETAIL
SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
1-„ -- TIMBERLINE T101
A3 (OR EQUIV) LOCKS - -- OVERLAY DRAWERS
ALL DRAWERS
DRAWER FACES - --
FORMICA BLACK
ON F.R. MDF.
FORMICA CC2 NEW WHITE - --
ON F.R. MDF
TOE KICK PLAN VIEW
61 l/2
32° 39"
L.. 3 1/2.
}_ - -1-
COUNTER TOP PLAN VIEW
32 1 /2"
42'
9_6/8
133/4» 15718"
CABINET SIDE ELEVATION
681/2" - ._.....
64 1 /2"
2,
r
�3"
A3
- -- - KICK 1 mm METAL - STAINLESS STEEL
OVER F. R. CURED MDF
16' DRAWER RUNNERS
HAFELE/ACCURIDE *3832 TO HOLD
4600 KILOGRAMS PER PAIR
COUNTER TOP OUTLINE
SOLID COUNTERTOP
DUPONT CORVW COBALT
(OR EQUIV. )
SECTION 1 -1
DRAWER CABINET DETAIL
'.. CENTER CABINET PANEL TO BE
SOLID SINGLE PIECE FOR RIGIDITY
DETAIL 3 -A3
CENTER CUTOUT PANEL
DIMENSIONS
321/2"
4"
4°
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 3 2012
City of Tukwila
BUILDING DIVISION
1-
U
UJ
CC
CC
0
a.
L)
U
00
m
0
J
uJ
w
J
w
W
N
Q'
O
¢
H
U
CC
IL
w
0
w
CC
N_
w
CJI
CCw
W
rn
CO
CO
J
J
¢
¢
0
0_
U
rn
W
¢
cn
oa
J
O
0
x
r
>-
CO
N
N
U
U
MATERIAL SCHEDULE
PRODUCT KIOSK
GRAPHIC HEADER LASER CUT LAMINATE OVER 1/4" (5mm) SIGN WHITE ACRYLIC PANEL WITH BLUE TRANSLUCENT VINYL
PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
CABINET BODY FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF
PIANO HINGE FOR CABINET DOORS WHERE APPLICABLE
CABINET SLIDING DOORS TEMPERED GLASS ON SLIDE TRACKS WITH LOCKS
SLIDING DRAWERS FORMICA BLACK OVER F.R. CURED MDF
DRAWER RUNNERS HAFELE /ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR
KICK 1mm BRUSHED STAINLESS STEEL
UPPER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.)
UPPER COUNTER STANDARDS FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF
LOWER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.)
PYLON SIGN ELEMENT
PYLON SIGN ELEMENT FORMICA WHITE OVER F.R. CURED MDF INTERNAL FLOURESCENT ILLUMINATION
SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
INTERNAL ILLUMINATION BY HERA T5 SLIMLITE FLOURESCENT FIXTURES (OR EQUIVALENT}
SIDE PANELS OF 1/4" TRANSLUCENT WHITE ACRYLIC WITH BLUE TRANSLUCENT VINYL
PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
REFERENCE MONITOR 26" (DIAG.) HD VIZIO RAZER M261VP
GRAPHIC PANEL DOOR ELEMENT
PERIMETER ILLUMINATED BACKLIT LED PANEL
PANEL ASSY. OF 1/4" CLEAR ACRYLIC PANEL OVER 1/16 1 DURATRANS GRAPHIC APPLICATION WITH
FRAME MTD. LED ILLUMINATION PANEL (1/41) TRANSFORMER MTD. TO CABINET INTERIOR.
CABINET DOORS 1W TOUCH LATCH 2OmmF.R MDF FORMICA BRIGHT WHITE
EUROPEAN HINGES WHERE REQUIRED
FLOORING
RECEIVE
MAR 13 2017
PERMIT CENTER:
4920
aISTERED
A'. I T
MICHAEL C. RAYMOND
STATE OF WASHINGTON
KIOSK TENANT IMPROVEMENT FOR
- SOUTHCENTER
2800 SOUTHCENTER MALL, STE. K -0859
TUKWILA, WASHINGTON 98188
tiv)
v
cm.)
+NI
•� c'
r-
r;
0
0
00
PLANNERS
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
JOB NO.
12 -001
OF
SHEET
A -1.4
SHEETS
El
SWITCHED 4 -WAY
- -- __ _ --:
. UNSWITCHEO 4 -WAY
_r.
-. _- - - -- -
- C $.,.....
n
_____.:5,
"Qm
1
1-v
P'
'
—POs
0.rt
- --- 1IGHTS
CPU
POWER SOURCE
FIG (NCr APrirw
r "4i,
_
"°°`''''''` i rt hn,T'1ACn
1-
..- �•' --
rE •
+JI
02;
,ViC,Ilk0i0 80A
iE .
{�
3JACC T_E. K "R'..4,,E0
p_:':i H • Jrlk
+1 "3F� t_ . =':V C •
NOTE:
ILLUSTRATIONS ARE FOR
POWER PATH REFERENCE
ONLY AND DO NOT DEPICT
ACTUAL WIRE LOCATIONS.
s
.1,-,
- ---- -t
_ rLcuRra-,E I F,,T RE
1
a rE IRE$ Er T iFE
'ELEPHONEPwrw ourLr T
t
`=+PE L F n.
.0 MO'
ai
f66
_.:A BPE.. ER LKX
-.
•
HARD •IR0.0.,
—.-
C ..X• ATTACHME•1-
•t
+° r ��'
ELECTRICAL LOAD SUMMARY
PRODUCT
MANUFACTURER
PART #
AMPS
QNTY
AMPS
LIGHTING FIXTURE XL T5
SLIMLITE
ES24
.116
4
464
0.932
LIGHTING FIXTURE XL T5
SLIMLITE
ES48
0.233
4
26" LCD HDTV **
VIZIO
M26VP
.1882
1
.1882
BLUE RAY PLAYER"
VIZIO
VBR220
0.20
1
020
POS^
IBM SURE
700 SERIES
2.10
2
4.2
lr Pos
TAPE LED LIGHTS*
OUTWATER PLASTICS
LED - RIBBON-
034/it
60ft
2.04
24V -W
LED BACKLIT PANELS*
E2 DISPLAYS
.034/ft
8ft
0.272
8.2962
CPU ),
.. .... -.
TOTAL AMPS
.... FAD N!- ELEVArp}!
ALL ELECTRICAL COMPONENTS TO BE UL APPROVED
ALL WIRING TO BE CONCEALED WITHIN CABINET STRUCTURE
EXCEPT WHERE END USER ACCESS DICTATES OTHERWISE.
• catum[a4 at °•■ ;Kw t?.ecnon. 30/s7.4 ,0& "21.,•= 034AA$G=:. 4
•• TWa■ • e, cT to [ras9a. 0,.0 saw] +M aV makG wlpweg.4r...
• INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED
• ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING
• ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED
• ALL SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES.
KICK 1 mm THK STAINLESS STEEL
OVER F.R. CURED MDF
42"
1/2° BOLT HOLES FOR PYLON ATTACH.
BOTH SIDES FOR UNIVERSAL FIT
A3 7
CENTER PANEL CUT ours Y
REFERENCE DETAIL 3 -A3 - --
SECTION 2 -2
DRAWER CABINET DETAIL
SOLID COUNTERTOP
DUPONT CORIAN COBALT
(OR EQUIV.)
1-„ -- TIMBERLINE T101
A3 (OR EQUIV) LOCKS - -- OVERLAY DRAWERS
ALL DRAWERS
DRAWER FACES - --
FORMICA BLACK
ON F.R. MDF.
FORMICA CC2 NEW WHITE - --
ON F.R. MDF
TOE KICK PLAN VIEW
61 l/2
32° 39"
L.. 3 1/2.
}_ - -1-
COUNTER TOP PLAN VIEW
32 1 /2"
42'
9_6/8
133/4» 15718"
CABINET SIDE ELEVATION
681/2" - ._.....
64 1 /2"
2,
r
�3"
A3
- -- - KICK 1 mm METAL - STAINLESS STEEL
OVER F. R. CURED MDF
16' DRAWER RUNNERS
HAFELE/ACCURIDE *3832 TO HOLD
4600 KILOGRAMS PER PAIR
COUNTER TOP OUTLINE
SOLID COUNTERTOP
DUPONT CORVW COBALT
(OR EQUIV. )
SECTION 1 -1
DRAWER CABINET DETAIL
'.. CENTER CABINET PANEL TO BE
SOLID SINGLE PIECE FOR RIGIDITY
DETAIL 3 -A3
CENTER CUTOUT PANEL
DIMENSIONS
321/2"
4"
4°
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 3 2012
City of Tukwila
BUILDING DIVISION
1-
U
UJ
CC
CC
0
a.
L)
U
00
m
0
J
uJ
w
J
w
W
N
Q'
O
¢
H
U
CC
IL
w
0
w
CC
N_
w
CJI
CCw
W
rn
CO
CO
J
J
¢
¢
0
0_
U
rn
W
¢
cn
oa
J
O
0
x
r
>-
CO
N
N
U
U
MATERIAL SCHEDULE
PRODUCT KIOSK
GRAPHIC HEADER LASER CUT LAMINATE OVER 1/4" (5mm) SIGN WHITE ACRYLIC PANEL WITH BLUE TRANSLUCENT VINYL
PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
CABINET BODY FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF
PIANO HINGE FOR CABINET DOORS WHERE APPLICABLE
CABINET SLIDING DOORS TEMPERED GLASS ON SLIDE TRACKS WITH LOCKS
SLIDING DRAWERS FORMICA BLACK OVER F.R. CURED MDF
DRAWER RUNNERS HAFELE /ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR
KICK 1mm BRUSHED STAINLESS STEEL
UPPER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.)
UPPER COUNTER STANDARDS FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF
LOWER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.)
PYLON SIGN ELEMENT
PYLON SIGN ELEMENT FORMICA WHITE OVER F.R. CURED MDF INTERNAL FLOURESCENT ILLUMINATION
SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
INTERNAL ILLUMINATION BY HERA T5 SLIMLITE FLOURESCENT FIXTURES (OR EQUIVALENT}
SIDE PANELS OF 1/4" TRANSLUCENT WHITE ACRYLIC WITH BLUE TRANSLUCENT VINYL
PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230
REFERENCE MONITOR 26" (DIAG.) HD VIZIO RAZER M261VP
GRAPHIC PANEL DOOR ELEMENT
PERIMETER ILLUMINATED BACKLIT LED PANEL
PANEL ASSY. OF 1/4" CLEAR ACRYLIC PANEL OVER 1/16 1 DURATRANS GRAPHIC APPLICATION WITH
FRAME MTD. LED ILLUMINATION PANEL (1/41) TRANSFORMER MTD. TO CABINET INTERIOR.
CABINET DOORS 1W TOUCH LATCH 2OmmF.R MDF FORMICA BRIGHT WHITE
EUROPEAN HINGES WHERE REQUIRED
FLOORING
RECEIVE
MAR 13 2017
PERMIT CENTER:
4920
aISTERED
A'. I T
MICHAEL C. RAYMOND
STATE OF WASHINGTON
KIOSK TENANT IMPROVEMENT FOR
- SOUTHCENTER
2800 SOUTHCENTER MALL, STE. K -0859
TUKWILA, WASHINGTON 98188
tiv)
v
cm.)
+NI
•� c'
r-
r;
0
0
00
PLANNERS
DRAWN
OFFICE
CHECKED
MCR
DATE
03/07/12
SCALE
JOB NO.
12 -001
OF
SHEET
A -1.4
SHEETS