Loading...
HomeMy WebLinkAboutPermit D12-085 - WESTFIELD SOUTHCENTER MALL - GHOST ARMOR - KIOSKGHOST ARMOR 2800 SOUThCENTER MALL K -0859 D12 -085 City oPi'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Project Name: GHOST ARMOR Permit Number: D12-085 Issue Date: 04/26/2012 Permit Expires On: 10/23/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: VINH TRAN Address: 952 E BASELINE RD, SUITE 106 , MESA AZ 85204 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA 98580 Contractor License No: JEMCOI *033DD Lender: Name: Address: Phone: 480 - 208 -3100 Phone: 253 843 -2765 Expiration Date: 05/15/2013 DESCRIPTION OF WORK: INSTALLATION OF KIOSK FOR THE SALE OF ELECTRONIC SCREEN AND BACK PROTECTORS Value of Construction: $25,000.00 Fees Collected: $937.25 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II-B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -085 Printed: 04 -26 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: - )-6 IN I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: .n.�� i1n X �—-ti Date: 4 f 2(n f i 2_ Print Name: �} l tt•)\ p�� L-L r✓1� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: IBC -7110 D12 -085 Printed: 04 -26 -2012 shall not be valid. The issuance of a permit l d on construction documents and other data 11 not prevent the Building Official from requiring the correctiW errors in the construction documents and data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Post address on kiosk per approved Westfield standards. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 11: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -085 Printed: 04 -26 -2012 Site Address: Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For office "use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's T r tS ie 7..c800 SoviltCOs�f Li PIA. - ISetcrRE Suite C2 i- *442440 tz. Mi. PROPERTY OWNER Company Name: .6 2. ��. `ax.rk pit,j Name: WE 'F1Q..n Name: V t 14 ; Address: 11(00 1 ski,l c' `ttze 4 ,1U t'TH Ftcotl- City: Los "a_vs State: CA Zip: q:02.c CONTACT PERSON - person receiving all project communication Company Name: .6 2. ��. `ax.rk pit,j Address: ` \(o f `"`A 3D0 c.g.1"- Name: V t 14 ; Phone: Cam\ 5 41 bpd Fax: 2Y t etc q 1 le 1 Contr Reg No.: Exp Date: Tukwila Business License No.: Address: O 2 e R.A8.eL1 f4 (2.1) # \040 Phone: lai G s- 4ubbFax: (60 sue- bS il i to City: A State: A Zip: i�-'2 Phone: 1 bb 20b 30c Fax: t jbo 14,(o 3i5�0'9 0 Email: V144 ,C40s,T- POQ.Cot4 GENERAL CONTRACTOR INFORMATION Company Name: .6 2. ��. `ax.rk pit,j Address: ` \(o f `"`A 3D0 c.g.1"- City :T 1.,pt C liy State: 07 Zip: st I t l is- Phone: Cam\ 5 41 bpd Fax: 2Y t etc q 1 le 1 Contr Reg No.: Exp Date: Tukwila Business License No.: H: \Applications \Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -11. docx Revised: August 2011 bh • • New Tenant: Floor: :48T. ❑ Yes g..No ARCHITECT OF RECORD Company Name: . FAe(l`CAT \6,\ 1 �! Company Name: .Z F'A59-1CAT1(51.1/4.) Address: l'i Log- &o.rt 7>o■ V4 A- Architect Name: -o A O cD0 A L Phone: ?)0t SOs- i 1 0 Fax: 'ibotO1 sts -- 4 i v Address: Q-4- So■Yni 3c>o v.liaST City: v 1 City: ,1S11" -1-- 1-°' c'*{State: ()T. Zip: Z Phone: lai G s- 4ubbFax: (60 sue- bS il i to Email: 1-0S*1tCa(,e7FA5•C -otA ENGINEER OF RECORD Company Name: . FAe(l`CAT \6,\ 1 �! Engineer Name:,�� � » ,_ ` 1. `""`�1 Address: l'i Log- &o.rt 7>o■ V4 A- City:C, r Lor C 1.1.,,State: `y„r. Zip: pis2D9 Phone: ?)0t SOs- i 1 0 Fax: 'ibotO1 sts -- 4 i v Email: `e:::¢ -150,) Do tJ C rAe . q 0,4 LENDER/BOND ISSUED (required for' projects $5,000 or greater per RCW 19.27.095) Name: (.'' ‘1/4flu`e e. Address: -1C2' S 35 't, 1,32" F-t AF (O co City: v 1 State: �--.._ Zip: aS Page 1 of 4 BUILDING PERMIT INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid price): $ d2 ) 00 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ n18ThLC,FtTt oF y-loSk-- Fla?, S4t, •E-1.,012DKJ l c_ Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers • Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Saf ty Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsWorms- Applications On Line \2011 Application\' rmit Application Revised - 8.9 -I l.docx Revised: August 2011 bh Page 2 of 4 Existing ' Interior Remodel ' Addition to ..:•. Existing . • Structure • : ' ; ' ` -. ' .• : i {rs F:: :New -7. e of'• �.Constructton;per , 'IBC • _ .�'yp'of-'.' ,06alipancy per :. • IBC '• ;; 1' Floor X \410S(2— Y.\r rd Floor 3rd Floor Floors . thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers • Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Saf ty Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsWorms- Applications On Line \2011 Application\' rmit Application Revised - 8.9 -I l.docx Revised: August 2011 bh Page 2 of 4 • • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR.'CU'TIIIORIZED AGENT: Signature: ' Print Name: `V (IsikA t■I Mailing Address: H:Wpplications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Date: Day Telephone: L19)0 20% 3 too City A•4- el-20(-1 State Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-085 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/13/2012 Applicant: GHOST ARMOR Issue Date: Receipt No.: R12 -01043 Initials: User ID: Payee: WER 1655 Payment Amount: $937.25 Payment Date: 03/13/2012 02:48 PM Balance: $0.00 GHOST ARMOR LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8159 937.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $937.25 565.30 367.45 4.50 doc: Receiot -06 Printed: 03 -13 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 612.-66? Project: Cast All 61O� Type of Inspection:. 1:21. IQ A' . Address: n% SdW $.11" VA A k' Date Called: . Specia Instructions: K~ S7 Date Wanted:. 1 Q — 1 "? -.I" a1rr,, Requester: Phone No: • 3 1 0 --q 1c.t -...6007 t Approved per applicable codes. a.Gnrrections required prior to approval. COMMENTS: Inspector. Dater • I REINSPECTION FEE REQUIRED. Prior to next inspectin. ;fee rn tp ust.be• paid at 6300 Southcenter Blud.. Suite 100. Call to schedule.reinspection. • • • • • • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1)la- o8S PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: ��5T A-ti Sprinklers: Type of Inspe n: . ',ie y J L Address: al9o0 9. C . vvvvt t-- Suite . #: f<_.... 0 (es---G ' � _ .'' . . Cog ' i on: Special Instructions: Permits: Phone No.: Occupancy Type: Yt":1--Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: ikl Sprinklers: Fire Alarm: Hood & Duct: Monitor: • Pre -Fire: . Permits: Occupancy Type: Inspector: ikl ,.., .9-... Date: 407/ '7// ZHrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 :! T.F.D. Form F.P. 113 • • 09 -04 -2012 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director VINH TRAN 952 E BASELINE RD, SUITE 106 MESA AZ 85204 RE: Permit No. D12 -085 GHOST ARMOR 2800 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/23/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/23/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D12 -085 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 • • OEM- GO COP\ PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D12-085 DATE: 03 -13 -12 PROJECT NAME: GHOST ARMOR SITE ADDRESS: 2800 SOUTHCENTER MALL - K -0859 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 16kJ& i - 1 1)-- vw 1 (, V 1,�. /l%�- S 12 dinc ivlson Fire Prevention Planning Division N( u Ic Wo s — IF Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -15 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 04 -12 -12 Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Prer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name J E M CONSTRUCTION INC UBI No. 601770782 Phone 2538432765 Status Active Address 29506 8Th Ave S License No. JEMC01'033DD Suite /Apt. License Type Construction Contractor City Roy Effective Date 3/4/1997 State WA Expiration Date 5/15/2013 Zip 98580 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MILLER, JAMES E President 01/01/1980 Amount Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SA7695 03/01/2002 Until Cancelled $12,000.00 03/19/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 American States Insurance Co 01C12205491 04/16/2011 04/16/2013 $1,000,000.00 04/13/2012 12 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2011 $1,000,000.00 04/21/2010 11 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2010 $1,000,000.00 04/17/2009 10 0010 CAS INS BL053040470 12/02/2008 12/02/2009 $1,000,000.00 11/20/2008 9 OHIO CAS INS BL00353040470 12/02/2003 12/02/2008 $1,000,000.00 11/27/2007 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 10 -2- 11928 -6 BROOKDALE LUMBER INC InterPlead: No PIERCE Date: 08/16/2010 Amount: $10,795.92 Bond(s): SA7695 Date: Amount: $0.00 Dismissed Date: Amount: Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 04/26/2012 LLEGAL AND SUBJECT TO PROSECUTION w KIOSK TENANT IMPROVEMENT FOR GHOST ARMOR SOUTHCENTER MALL 2800 SOUTHCENTER MALL, STE. K -0859 TUKWILA, WASHINGTON 98188 SEPARATE PERMIT REQUIRED FOR: M Electrical Plumbing City of Tukwila , BUILDING DIVISION OWN HP GHOST ARMOR 952 EAST BASELINE RD. SUITE 122 MESAS ARIZONA 85204 APCHIT HCT MICHAEL Co RAYMOND, AIA PROJECT ARCHITECT. 32 WEST CENTER ST. SUITE 203 PROVOS UTAH 84801 PH. # (801) 374 -2100 FAX # (801) 374 -0100 CODE INFORMATION OCCUPANCY: M TYPE CONSTRUCTION (MALL): TYPE IIB KIOSK ALLOWABLE AREA: 300 S.F. ACTUAL AREA: 68 S.F. NET AREA FIRE SPRINKLED: YES APPLICABLE BUILDING CODES: 2009 IBC, 2009 IEBC, 2009 UPC, 2008 WCEC, 2009 IMC, 2009 WSEC, 2003 ICC /ANSI INDEX TO DRAWI \GS ARCHITECTURAL A -1.1 A-12 A -1.3 A -1.4 TENANT KIOSK FLOOR PLAN & DETAILS KIOSK DETAILS KIOSK DETAILS KIOSK DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED MAR 232012 City of Ia BUILDIN VISION FILE COPY Phr regkra approvel is subject to WON and omlvdons. Approval of construction documents does not authorize v;alation of any adopted code or oi nanc e. Receipt • 412-to I.7_ i t 2, C'Iht Of 1'is WILDING DIVISION 9$3a1 °.., $ 11 ix saw a rn Se* SW VICINITY MAP NORTH macy 4 .E Fl GHOST ARMOR SUITE: K -0859 JC:I R1-1 .-;, ,1. LOCATIO\ PLAN - ACRYUC $ACKLI7 rmi' TRANSLUCENT !MITE LASER CtsT LOGO ON BOTH SIDES OF PYLON PUSH THROUGM ACRYLIC LETTERING WITH VINYL BLUE OVERLAY — TRANSLUCENT VVHITE ACRYLIC BACKLIT LIGHT FIXTURE BEHIND CUT OUT NOTE: THIS PAGE IS FOR ILLUSTRATION PURPOSES AND IS INTENDED FOR REFERENCE ONLY• I YOUR SPECIFIC CONFIGURATION MAY VARY DUE TO VARIABLES SUCH AS, BUT NOT LIMITED TO: INSTALLATION REQUIREMENTS. GEOGRAPHIC FEATURES. TRAFFIC FLOW REQUIREMENTS, SITE SIZE REQUIREMENTS AND AGREEMENTS . FOR TENANT APPROVAL BASED UPON AN ACCURATE DEPICTION OF A SPECIFIC KIOSK: DOCUMENTS SHOWING THE SITE AND RELATIVE POSITION OF THE INSTALLATION SHOULD BE OBTAINED AS SOON AS POSSIBLE FROM THE SITE MANAGER 1 COORDINATOR AND SUPPLIED TO e2 DESIGN AND FABRICATION FOR PREPARATION OF INSTALLATION DOCUMENTS AND GRAPHIC REPRESENTATION. 1— U 0_ W N NC. PROVO, UTAH. ALL RIGHTS RESERVED. UNAUTHO uJ W LO —1 2012 BY RAYMOND, VAN NOSD 1— U C : \Userslsanthony\ Desktop \SCR1I1-0VE1- 20120306.dwg, 3/6/2012 9:18:31 AM, CLEARANCE PDF PLA\ Combustible kiosks or other structures shall not be located within the mall unless constructed of any of the following materials: 1.4 Fire - retardant- treated wood complying with IBC Section 2303.2 1.5 Foam plastics having a maximum heat release rate not greater than 100kW (105 Btu/h) when test in accordance with the exhibit booth protocol in UL 1975. Aluminum composite material (ACM) having la flame spread index of not more than 25 and a smoke - developed index of not more than 450 when tested as an assembly in the maximum intended for the use in accordance with ASTM E 84 or UL 723. CLO REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT:: Revisions will require a new plan submittal 1 and may include additional plan review fees. i 61 12" 23 `e/ 2U 5dr- - - ? -�' 78' 32 -_ - - -- - 1:1. - - - -- PYLON «8 112'• - 23 1 23 34• 12112° REF. DRAWINGS). A2 2 -. REF DRAWINGS) -A2 REFERENCE DRAWING 42 2 - r .1.° 1 1420 RENEE DRAWING 2.2 .4 REF DRAVONG:51 A -1 10x10 -2 REF DRA -- - - -REF DRA NG5) 2.3 2O95 2 RECEIVED MAR 13 2012 HERMIT CENTER REVISIONS 1 BY DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE JOB NO. 12 -001 OF SHEET A-1.1 SHEET* LLEGAL AND SUBJECT TO PROSECUTION L RIGHTS RESERVED. UNAUTHORIZED REPRODUCTION AN NC. PROVO, UTA 2012 BY RAYMOND, VAN NOSDOL & UPPER COUNTER TOPS DuPONT CORIAN COBALT (OR EQUIV.) SOLID MATERIAL SURFACE COUNTER TOP DUPONT CORIAN COBALT SOLID MATERIAL SURFACE (OR EQUIV.) COUNTER TOP DUPONT CORIAN COBALT SOLID MATERIAL SURFACE (OR EQUIV.) TRASH CUT- OUT - 6" DIAMETER r 4•r 35 1/2' 20 5/8 " -- 11 112''! 12 3/4" 11 1/2" 121/8" A1.2 21 7/8" 251 /2" 25 1/2" 24 5/8" 75 1/4 " COUNTER TOP DETAIL PLAN VIEW BACKSPLASH "SHIM" LOCATES BETWEEN STANDARD AND ADA COUNTER ELEMENTS DUPONT CORIAN COBALT (OR EQUIV.) TOE KICK DETAIL PLAN VIEW KICK 1 mm METAL - STAINLESS STEEL OVERF.R. CURED MDF • INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED • ALL STUCTURAL CONST. MATLS FIRE RATED • ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING • ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED • ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES. DRAWER RUNNERS HAFELE/ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR BACK PANEL NOTE' - BuIL0 IN 5 SEPERATE CABINETS MC THEN ATTACH TOOET/ER BACK CENTER PANEL -- COUNTER TOP OUTLINE Al - 221/2' •• GARBAGE/ EXTRA STORAGE. FORMICA CC2 (NEW WHITE) - ON F.R. MDF. 1 1/2" - SECTION 1 -1 Al- -- COUNTER TOP OUTLINE :TIMBERLINE T101'- /` (OR EQUIV) LOCK , 108 " - -- 2 DETAIL 2 Al GLASS TRACK DETAILS REF.ONLY 1 23 1/2 ", 23241/2" 17 174" TIMBERLINE T101 (OR EQUIV.) LOCK j.r OVERLAY DOOR / DRAWER- LEFT .SIDE ELEVATION i 1/2" r 1 8 BACKLIT LED GRAPHIC PANEL 24 112' - FRONT ELEVATION 33 8/8' -- 74' - 33 5/8" -- SHELVES WITH PINS ON SIDE WALLS Ai - -TOE KICK DETAILS REF DWG. A1.2 - SLIDING TEMPERED GLASS DOOR WITH LOCK RIGHT SIDE ELEVATION • INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED • ALL STUCTURAL CONST. MATLS FIRE RATED • ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING • ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED • ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES. PYLON ELEMENT RESTS HERE 34" DRAWER DRAWER RUNNERS HAFFI F /ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR FORMICA CC2 (NEW WHITE)-- - ON F . MDF. 34" . 4" -. 24" 8 112" -- 10" 123/■" , f, 3",- L� 18 314" GARBAGE EXTRA STORAGE 10" COUNTER TOP OUTLINE SECTION 1 -1 Al At 5114•'I 3 "-4 74" 108 "__ A.2 3 COUNTER TOP OUTLINE TIMBERLINE T101 (OR EOUIV) LOCK A2 2`.DETAIL 2 A2 CLASS DETAILS REF ONLY TIMBERLINE T101 (OR EQUIV) LOCK 25" 26 1/2" 17 1/4" '. 17 TIMBERLINE T101 (OR EQUIV.) LOCK - -LEFT "SIDE ELEVATION 1 1/2" TO POWER SOURCE 34 1/2" 36" 33 5/8" BACK ELEVATION FRONT -_ -_. ELEVATION .........< .. 33 5/8" - -- - 74'...- • - - -- SHELVES WITH PINS ` ON SIDE WALLS Ire 17• 8' BACKLIT LED GRAPHIC PANEL SLIDING TEMPERED GLASS DOOR WITH LOCK 4 10 1/2" 3/4' 1_,_ PYLON SHELF RESTS ON BACK PANEL CUTOUT COUNTER TOP OUTLINE --TOE KICK DETAILS REF DWG. A2 2 - RIGHT `SIDE ELEVATION • INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED • ALL STUCTURAL CONST. MATLS FIRE RATED • ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING • ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED • ALL LAMINATE SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES. 61 81" 231/2' -- 23 1/2" •' 6 1/2"'+ 4 SHELF DETAIL PLAN VIEW 231 /2" - -- - -- •6 12" t44 SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) - -- FORMICA CC2 (NEW WHITE) OVER F.R. CURED MDF _ 4 1/2" 23 1/2' SHELF DETAIL FRONT ELEVATION -3 1/2" 51" SHELF DETAIL SIDE ELEVATION A1.3 31!2° • I.- REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 3 2012 City of Tukwila BUILDING DIVISION P1.- °Ss RECEIVE(' MAR 13 2012 PERMIT CENTEF REVISIONS BY EGISTERED HITE T MICH L C. RAYMOND STATE OF WASHINGTON Raymond .Van Nosdol & Assoc. Inc Ray DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE JOB NO. 12 -001 OF SHEET A -1.2 SHEET ILLEGAL AND SUBJECT TO PROSECUTION. NC. PROVO, UTAH. ALL RIGHTS RESERVED. UNAUTHDRIZED REPRODUCTION AND /OR USE 2012 BY RAYMOND, VAN NOSDOL 37 1 36' 37 1/2" 39 1/2" 32" 20 5/8" TRASH CUT -OUT 6" DIAMETER 12 1/8" 6" 7 1/2" -75 114' 1 1/2" COUNTER TOP DETAIL PLAN VIEW TOE KICK DETAIL PLAN VIEW 8" HUBERT 8" STAINLESS STEEL RECEPTACLE LID PT# 41281 SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) KICK 1 mm METAL - STAINLESS STEEL OVER F.R- CURED MDF A2.2 REVIEWED FOR CODE c R VEO CE APP CROSS SECTIONS PYLON SIGN ELEMENT DETAIL -2 6 1/2" 81" DETAIL -1 A2 23 1/2" i t 9 1/2" -. 23 1/2" a- 61/2 "-. 32" -SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) PYLON 6 1/2" A2.4 91/2" ..- 3 1/2" 23 1/2" FORMICA CC2 (NEW WHITE) OVER F.R. CURED MDF =61/2 "+ MAR 2 3 2012 CitiNG DIVISION 1S1CN CROSS SECTIONS PYLON SIGN ELEMENT DETAIL -2 r. 1" - 1 C SLOT FOR REMOVAL OF i - SIDE ACRYLIC PANEL .: (PANEL SLIDES UP FOR - - - REMOVAL) -x..25 1 /4"d CHANNEL FOR SIDE ACRYLIC PANEL HERA T -5 SLIMLITE _ 48" (46.75) h OR EQUIV. 48" {► ALL BLOCKING OF TO COUNTERTOP =■ KILN DRIED 60" i F.R. 3/4" MDF F {r• VIZIO M26VP MONITOR l i 6" 1 A 18" "+ 12" T 6" t L__ 1_ -� 1 SECTION 1 -__ NOTE: INTERNALLY ILLUMINATED PORTION OF THIS FEATURE 1/4" SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL FILM: PANTONE 299C2X PROCESS BLUE 3M SCOTCHCAL SERIES 230 FILM 32" "GHOST ARMOR" LOGO LASER CUT (BOTH SIDES - REVERSE SIDE SHOWN CUTAWAY VIEW) a- 6" .". 0-2 "-' +1 /2" 3/4" u T u: 29 112" ►. ►5 112 " -rt 1 I 1 114" ,. 3" 31/4" .: 1 i . - i T /8" , , -- _ -- P- 3/4" WIDE DAIDO 12 3/4 ,.-F RECESS '. r , 27" ±- ' T 2 3/4" "` i ..m i 'i4 1/2" _ 5/8 . 22 7/$ F i I ,, .=!,r 44" 2T' -- • i 6" 7 1/2" t s 20" �- SIDE BLOCKING FOR HERA T5 OR EQUIV. SIGN WHITE ACRYLIC PANEL RECESSED INTO FRONT AND BACK PYLON BLOCKING AS REQ'D TO RETAIN MONITOR NOTE: BLOCKING BE REMOVABLE FOR MONITOR INSTALLATION AND PLACEMENT FLOATING SHELF TO ACCOMODATE DIFFERING MONITOR MODELS UTILIZE SPACER BLOCKS BENEATH ADJUST HEIGHT (MONITOR MUST BE 26" DIAG.) FRONT AND REAR PANELS OF 1/2" F.R. CURED MDF TO ELIMINATE ANY AND ALL WARPAGE LWR. COUNTER TOP 2ND LAYER 3/4" F.R,V MDF FOR BOLT THROUGH ATTACHMENT A2.4 i - a c - o c 1/4" PANELS MUST TO TO HERE 1" �. � ..,. REF. A2.4b f 6" j T 1. i 1 1/2" 0- 6" -.4 - -- 1/2" BUILDUP THIS LOCATION CREATES 1" STROKE AROUND ACRYLIC PANEL �`a TO COUNTER TOP ELEVATION - '_SECTION 2 MTG PLATE OF 2 LAYERS 3/4" A2 KILN DRIED F.R. MDF TO INSIDE CABINET OUTLET DETAIL 3 ELECTRICAL COMPONENT DETAILS 1z. __ 20A SINGLE POLE SWITCH } , iR1NCTION BOX POWER SOURCE 36,; MIN EXTENSION TO MALE GRNDD 20A PLUG ALL ELECTRICAL COMPONENTS UL APPROVED REFERENCE DRAWING El FOR LAYOUT, ROUTING AND COMPONENT SPECIFICATIONS ALL ELECTRICAL COMPONENTS UL APPROVED DETAIL 4 LED BACKLIT DOOR PANEL DETAIL DEDICATED SWITCHED 4 -WAY FOR LIGHTED ELEMENTS RETAINING (SCREW 181/4" l 3/4" A2.3 FRAME ATTACH) PANEL PANEL T101 LOCK EDICATED UNSWITCHED 4 -WAY FOR POS AND COMPUTER SYSTEMS 1/2"a- .+ ► 3" 41 20A SINGLE POLE BREAKER T_ CLEARANCE FOR HINGE AS REQUIRED _ 2" -"a 25" WIRE TO TRANSFORMER s ELECTRICAL CLEARANCE FOR HINGE AS REQUIRED _- _ .: .. 19" 1 17 1/4" - -___ 23 1/8" 19 318" i 20" 19 3/8" - 181/2" 171/2" __... +~ 21" T ► ►. 1 /2" - 3" -. LEGEND = LED PANEL ► ■ = DURATRANS GRAPHIC ,. = v4" ACRYLIC DOOR FRAME l TIMBERLINE (OR EQUIV) 21" INSIDE VIEW LED BACKLIT DOOR 37 1 36' 37 1/2" 39 1/2" 32" 20 5/8" TRASH CUT -OUT 6" DIAMETER 12 1/8" 6" 7 1/2" -75 114' 1 1/2" COUNTER TOP DETAIL PLAN VIEW TOE KICK DETAIL PLAN VIEW 8" HUBERT 8" STAINLESS STEEL RECEPTACLE LID PT# 41281 SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) KICK 1 mm METAL - STAINLESS STEEL OVER F.R- CURED MDF A2.2 REVIEWED FOR CODE c R VEO CE APP CROSS SECTIONS PYLON SIGN ELEMENT DETAIL -2 6 1/2" 81" DETAIL -1 A2 23 1/2" i t 9 1/2" -. 23 1/2" a- 61/2 "-. 32" -SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) PYLON 6 1/2" A2.4 91/2" ..- 3 1/2" 23 1/2" FORMICA CC2 (NEW WHITE) OVER F.R. CURED MDF =61/2 "+ MAR 2 3 2012 CitiNG DIVISION 1S1CN o ss RECEIVED MAR 13 2012 PERMIT CENTEP 4920 GISTERED IT CT MICHAEL C. RAYMOND STATE OF WASHINGTON TENANT IMPROVEMENT FOR CID - SOUTHCENTER 2800 SOUTHCENTER MALL, STE. K -0859 TUKWILA, WASHINGTON 98188 v Raymond Van Nosdol & Assoc. (801) 374 -2100 PLANNERS ARCHITECTS DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE J013 NO. 12 -001 SHEET A -1.3 OF SHEETS CROSS SECTIONS PYLON SIGN ELEMENT DETAIL -2 r. 1" - 1 C SLOT FOR REMOVAL OF i - SIDE ACRYLIC PANEL .: (PANEL SLIDES UP FOR - - - REMOVAL) -x..25 1 /4"d CHANNEL FOR SIDE ACRYLIC PANEL HERA T -5 SLIMLITE _ 48" (46.75) h OR EQUIV. 48" {► ALL BLOCKING OF TO COUNTERTOP =■ KILN DRIED 60" i F.R. 3/4" MDF F {r• VIZIO M26VP MONITOR l i 6" 1 A 18" "+ 12" T 6" t L__ 1_ -� 1 SECTION 1 -__ NOTE: INTERNALLY ILLUMINATED PORTION OF THIS FEATURE 1/4" SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL FILM: PANTONE 299C2X PROCESS BLUE 3M SCOTCHCAL SERIES 230 FILM 32" "GHOST ARMOR" LOGO LASER CUT (BOTH SIDES - REVERSE SIDE SHOWN CUTAWAY VIEW) a- 6" .". 0-2 "-' +1 /2" 3/4" u T u: 29 112" ►. ►5 112 " -rt 1 I 1 114" ,. 3" 31/4" .: 1 i . - i T /8" , , -- _ -- P- 3/4" WIDE DAIDO 12 3/4 ,.-F RECESS '. r , 27" ±- ' T 2 3/4" "` i ..m i 'i4 1/2" _ 5/8 . 22 7/$ F i I ,, .=!,r 44" 2T' -- • i 6" 7 1/2" t s 20" �- SIDE BLOCKING FOR HERA T5 OR EQUIV. SIGN WHITE ACRYLIC PANEL RECESSED INTO FRONT AND BACK PYLON BLOCKING AS REQ'D TO RETAIN MONITOR NOTE: BLOCKING BE REMOVABLE FOR MONITOR INSTALLATION AND PLACEMENT FLOATING SHELF TO ACCOMODATE DIFFERING MONITOR MODELS UTILIZE SPACER BLOCKS BENEATH ADJUST HEIGHT (MONITOR MUST BE 26" DIAG.) FRONT AND REAR PANELS OF 1/2" F.R. CURED MDF TO ELIMINATE ANY AND ALL WARPAGE LWR. COUNTER TOP 2ND LAYER 3/4" F.R,V MDF FOR BOLT THROUGH ATTACHMENT A2.4 i - a c - o c 1/4" PANELS MUST TO TO HERE 1" �. � ..,. REF. A2.4b f 6" j T 1. i 1 1/2" 0- 6" -.4 - -- 1/2" BUILDUP THIS LOCATION CREATES 1" STROKE AROUND ACRYLIC PANEL �`a TO COUNTER TOP ELEVATION - '_SECTION 2 MTG PLATE OF 2 LAYERS 3/4" A2 KILN DRIED F.R. MDF TO INSIDE CABINET OUTLET o ss RECEIVED MAR 13 2012 PERMIT CENTEP 4920 GISTERED IT CT MICHAEL C. RAYMOND STATE OF WASHINGTON TENANT IMPROVEMENT FOR CID - SOUTHCENTER 2800 SOUTHCENTER MALL, STE. K -0859 TUKWILA, WASHINGTON 98188 v Raymond Van Nosdol & Assoc. (801) 374 -2100 PLANNERS ARCHITECTS DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE J013 NO. 12 -001 SHEET A -1.3 OF SHEETS • INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED • ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING • ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED • ALL SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES. KICK 1 mm THK STAINLESS STEEL OVER F.R. CURED MDF 42" 1/2° BOLT HOLES FOR PYLON ATTACH. BOTH SIDES FOR UNIVERSAL FIT A3 7 CENTER PANEL CUT ours Y REFERENCE DETAIL 3 -A3 - -- SECTION 2 -2 DRAWER CABINET DETAIL SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) 1-„ -- TIMBERLINE T101 A3 (OR EQUIV) LOCKS - -- OVERLAY DRAWERS ALL DRAWERS DRAWER FACES - -- FORMICA BLACK ON F.R. MDF. FORMICA CC2 NEW WHITE - -- ON F.R. MDF TOE KICK PLAN VIEW 61 l/2 32° 39" L.. 3 1/2. }_ - -1- COUNTER TOP PLAN VIEW 32 1 /2" 42' 9_6/8 133/4» 15718" CABINET SIDE ELEVATION 681/2" - ._..... 64 1 /2" 2, r �3" A3 - -- - KICK 1 mm METAL - STAINLESS STEEL OVER F. R. CURED MDF 16' DRAWER RUNNERS HAFELE/ACCURIDE *3832 TO HOLD 4600 KILOGRAMS PER PAIR COUNTER TOP OUTLINE SOLID COUNTERTOP DUPONT CORVW COBALT (OR EQUIV. ) SECTION 1 -1 DRAWER CABINET DETAIL '.. CENTER CABINET PANEL TO BE SOLID SINGLE PIECE FOR RIGIDITY DETAIL 3 -A3 CENTER CUTOUT PANEL DIMENSIONS 321/2" 4" 4° REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 3 2012 City of Tukwila BUILDING DIVISION 1- U UJ CC CC 0 a. L) U 00 m 0 J uJ w J w W N Q' O ¢ H U CC IL w 0 w CC N_ w CJI CCw W rn CO CO J J ¢ ¢ 0 0_ U rn W ¢ cn oa J O 0 x r >- CO N N U U MATERIAL SCHEDULE PRODUCT KIOSK GRAPHIC HEADER LASER CUT LAMINATE OVER 1/4" (5mm) SIGN WHITE ACRYLIC PANEL WITH BLUE TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 CABINET BODY FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF PIANO HINGE FOR CABINET DOORS WHERE APPLICABLE CABINET SLIDING DOORS TEMPERED GLASS ON SLIDE TRACKS WITH LOCKS SLIDING DRAWERS FORMICA BLACK OVER F.R. CURED MDF DRAWER RUNNERS HAFELE /ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR KICK 1mm BRUSHED STAINLESS STEEL UPPER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.) UPPER COUNTER STANDARDS FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF LOWER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.) PYLON SIGN ELEMENT PYLON SIGN ELEMENT FORMICA WHITE OVER F.R. CURED MDF INTERNAL FLOURESCENT ILLUMINATION SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 INTERNAL ILLUMINATION BY HERA T5 SLIMLITE FLOURESCENT FIXTURES (OR EQUIVALENT} SIDE PANELS OF 1/4" TRANSLUCENT WHITE ACRYLIC WITH BLUE TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 REFERENCE MONITOR 26" (DIAG.) HD VIZIO RAZER M261VP GRAPHIC PANEL DOOR ELEMENT PERIMETER ILLUMINATED BACKLIT LED PANEL PANEL ASSY. OF 1/4" CLEAR ACRYLIC PANEL OVER 1/16 1 DURATRANS GRAPHIC APPLICATION WITH FRAME MTD. LED ILLUMINATION PANEL (1/41) TRANSFORMER MTD. TO CABINET INTERIOR. CABINET DOORS 1W TOUCH LATCH 2OmmF.R MDF FORMICA BRIGHT WHITE EUROPEAN HINGES WHERE REQUIRED FLOORING RECEIVE MAR 13 2017 PERMIT CENTER: 4920 aISTERED A'. I T MICHAEL C. RAYMOND STATE OF WASHINGTON KIOSK TENANT IMPROVEMENT FOR - SOUTHCENTER 2800 SOUTHCENTER MALL, STE. K -0859 TUKWILA, WASHINGTON 98188 tiv) v cm.) +NI •� c' r- r; 0 0 00 PLANNERS DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE JOB NO. 12 -001 OF SHEET A -1.4 SHEETS El SWITCHED 4 -WAY - -- __ _ --: . UNSWITCHEO 4 -WAY _r. -. _- - - -- - - C $.,..... n _____.:5, "Qm 1 1-v P' ' —POs 0.rt - --- 1IGHTS CPU POWER SOURCE FIG (NCr APrirw r "4i, _ "°°`''''''` i rt hn,T'1ACn 1- ..- �•' -- rE • +JI 02; ,ViC,Ilk0i0 80A iE . {� 3JACC T_E. K "R'..4,,E0 p_:':i H • Jrlk +1 "3F� t_ . =':V C • NOTE: ILLUSTRATIONS ARE FOR POWER PATH REFERENCE ONLY AND DO NOT DEPICT ACTUAL WIRE LOCATIONS. s .1,-, - ---- -t _ rLcuRra-,E I F,,T RE 1 a rE IRE$ Er T iFE 'ELEPHONEPwrw ourLr T t `=+PE L F n. .0 MO' ai f66 _.:A BPE.. ER LKX -. • HARD •IR0.0., —.- C ..X• ATTACHME•1- •t +° r ��' ELECTRICAL LOAD SUMMARY PRODUCT MANUFACTURER PART # AMPS QNTY AMPS LIGHTING FIXTURE XL T5 SLIMLITE ES24 .116 4 464 0.932 LIGHTING FIXTURE XL T5 SLIMLITE ES48 0.233 4 26" LCD HDTV ** VIZIO M26VP .1882 1 .1882 BLUE RAY PLAYER" VIZIO VBR220 0.20 1 020 POS^ IBM SURE 700 SERIES 2.10 2 4.2 lr Pos TAPE LED LIGHTS* OUTWATER PLASTICS LED - RIBBON- 034/it 60ft 2.04 24V -W LED BACKLIT PANELS* E2 DISPLAYS .034/ft 8ft 0.272 8.2962 CPU ), .. .... -. TOTAL AMPS .... FAD N!- ELEVArp}! ALL ELECTRICAL COMPONENTS TO BE UL APPROVED ALL WIRING TO BE CONCEALED WITHIN CABINET STRUCTURE EXCEPT WHERE END USER ACCESS DICTATES OTHERWISE. • catum[a4 at °•■ ;Kw t?.ecnon. 30/s7.4 ,0& "21.,•= 034AA$G=:. 4 •• TWa■ • e, cT to [ras9a. 0,.0 saw] +M aV makG wlpweg.4r... • INTERIOR OF ALL CABINET TO BE LAMINATED & SEALED • ALL CABINET MATERIAL MUST BE CURED & KILN DRIED TO ELIMINATE ANY & ALL WARPING • ALL CABINET JOINERY MUST BE GLUED, STAPLED, & SCREWED • ALL SURFACES CHAMFERED & SMOOTHED NO SHARP EDGES. KICK 1 mm THK STAINLESS STEEL OVER F.R. CURED MDF 42" 1/2° BOLT HOLES FOR PYLON ATTACH. BOTH SIDES FOR UNIVERSAL FIT A3 7 CENTER PANEL CUT ours Y REFERENCE DETAIL 3 -A3 - -- SECTION 2 -2 DRAWER CABINET DETAIL SOLID COUNTERTOP DUPONT CORIAN COBALT (OR EQUIV.) 1-„ -- TIMBERLINE T101 A3 (OR EQUIV) LOCKS - -- OVERLAY DRAWERS ALL DRAWERS DRAWER FACES - -- FORMICA BLACK ON F.R. MDF. FORMICA CC2 NEW WHITE - -- ON F.R. MDF TOE KICK PLAN VIEW 61 l/2 32° 39" L.. 3 1/2. }_ - -1- COUNTER TOP PLAN VIEW 32 1 /2" 42' 9_6/8 133/4» 15718" CABINET SIDE ELEVATION 681/2" - ._..... 64 1 /2" 2, r �3" A3 - -- - KICK 1 mm METAL - STAINLESS STEEL OVER F. R. CURED MDF 16' DRAWER RUNNERS HAFELE/ACCURIDE *3832 TO HOLD 4600 KILOGRAMS PER PAIR COUNTER TOP OUTLINE SOLID COUNTERTOP DUPONT CORVW COBALT (OR EQUIV. ) SECTION 1 -1 DRAWER CABINET DETAIL '.. CENTER CABINET PANEL TO BE SOLID SINGLE PIECE FOR RIGIDITY DETAIL 3 -A3 CENTER CUTOUT PANEL DIMENSIONS 321/2" 4" 4° REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 3 2012 City of Tukwila BUILDING DIVISION 1- U UJ CC CC 0 a. L) U 00 m 0 J uJ w J w W N Q' O ¢ H U CC IL w 0 w CC N_ w CJI CCw W rn CO CO J J ¢ ¢ 0 0_ U rn W ¢ cn oa J O 0 x r >- CO N N U U MATERIAL SCHEDULE PRODUCT KIOSK GRAPHIC HEADER LASER CUT LAMINATE OVER 1/4" (5mm) SIGN WHITE ACRYLIC PANEL WITH BLUE TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 CABINET BODY FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF PIANO HINGE FOR CABINET DOORS WHERE APPLICABLE CABINET SLIDING DOORS TEMPERED GLASS ON SLIDE TRACKS WITH LOCKS SLIDING DRAWERS FORMICA BLACK OVER F.R. CURED MDF DRAWER RUNNERS HAFELE /ACCURIDE #3832 TO HOLD 45.00 KILOGRAMS PER PAIR KICK 1mm BRUSHED STAINLESS STEEL UPPER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.) UPPER COUNTER STANDARDS FORMICA COLOR CORE 2 7223C -FV (NEW WHITE) OVER F.R. CURED MDF LOWER COUNTER TOPS DUPONT COBALT SOLID MATERIAL SURFACE (OR EQUIV.) PYLON SIGN ELEMENT PYLON SIGN ELEMENT FORMICA WHITE OVER F.R. CURED MDF INTERNAL FLOURESCENT ILLUMINATION SIGN WHITE ACRYLIC PANEL WITH TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 INTERNAL ILLUMINATION BY HERA T5 SLIMLITE FLOURESCENT FIXTURES (OR EQUIVALENT} SIDE PANELS OF 1/4" TRANSLUCENT WHITE ACRYLIC WITH BLUE TRANSLUCENT VINYL PROCESS BLUE PANTONE 299C2X SCOTCHCAL SERIES 230 REFERENCE MONITOR 26" (DIAG.) HD VIZIO RAZER M261VP GRAPHIC PANEL DOOR ELEMENT PERIMETER ILLUMINATED BACKLIT LED PANEL PANEL ASSY. OF 1/4" CLEAR ACRYLIC PANEL OVER 1/16 1 DURATRANS GRAPHIC APPLICATION WITH FRAME MTD. LED ILLUMINATION PANEL (1/41) TRANSFORMER MTD. TO CABINET INTERIOR. CABINET DOORS 1W TOUCH LATCH 2OmmF.R MDF FORMICA BRIGHT WHITE EUROPEAN HINGES WHERE REQUIRED FLOORING RECEIVE MAR 13 2017 PERMIT CENTER: 4920 aISTERED A'. I T MICHAEL C. RAYMOND STATE OF WASHINGTON KIOSK TENANT IMPROVEMENT FOR - SOUTHCENTER 2800 SOUTHCENTER MALL, STE. K -0859 TUKWILA, WASHINGTON 98188 tiv) v cm.) +NI •� c' r- r; 0 0 00 PLANNERS DRAWN OFFICE CHECKED MCR DATE 03/07/12 SCALE JOB NO. 12 -001 OF SHEET A -1.4 SHEETS