Loading...
HomeMy WebLinkAboutPermit D12-086 - FITTERER / SPIKER RESIDENCE - ADDITIONFITTERER & SPIKER ADDITION 5145 S 168 ST D12 -086 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 8125200035 Address: 5145 S 168 ST TUKW Suite No: Project Name: FITTERER & SPIKER ADDITION Permit Number: D12 -086 Issue Date: 04/26/2012 Permit Expires On: 10/23/2012 Owner: Name: SPIKER CATHY J Address: 5145 S 168TH ST , SEATTLE WA 98188 Contact Person: Name: GREG HUGHES Address: PO BOX 410 , SEAHURST WA 98062 Contractor: Name: ALPINE RIDGE CONSTRUCTION INC Address: PO BOX 410 , SEAHURST WA 98062 Contractor License No: ALPINRC 13K2 Lender: Name: OWNER FUNDED Address: Phone: 206 246 -4063 Phone: 206 - 246 -4063 Expiration Date: 05/18/2014 DESCRIPTION OF WORK: CONSTRUCTION OF 597 SF FAMILY ROOM ADDITION OVER EXISITNG GARAGE WITH 94 SF SECOND STORY DECK OFF REAR OF DWELLING. Value of Construction: $72,711.21 Fees Collected: $1,975.10 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 22 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -086 Printed: 04 -26 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N / Permit Center Authorized Signature: 'I / ■ � �_ I hereby certify that I have read and examined t permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Date: �� C A/r The granting of this permit does not , resume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance ofv+'�orkiI am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. doc: IBC -7/10 D12 -086 Printed: 04 -26 -2012 7: All wood to remain in placed concrete shalt treated wood. • 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -086 Printed: 04 -26 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.TukwilaWA.gov Building Permit No. 1) '0/(0 Project No. V &rnrn_ '' '' JJ ++ I ("l I 11-• 01111-1 �i t Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE •I:OCAPON Site Address: 3_ 1' 5 50 1 Co 3 S_ Tenant Name: t% 1 CrL e-L IZ / 5 ? 1 k.ts e.. °RROE- RTYOWNER• Name: ��S Address: ?c �oX Li ( 0 Name: / ���.,. } ,iicr.�g 61. � S p, k-e r Address:'j'1 5 -,70 1 1 t 1 0 s T City• 1 lek State: Ij /k- Zip: 9' W` F( %CO1WIKCT.4..gSON peridn-recelving- allprglgct.-''- ticomniuiueaRoni :, -s i: 0a .. _. . .._.. . Name: ��S Address: ?c �oX Li ( 0 City:S 4 l,1 I�lf S + Stater A Zip: ! gOsf `�.,u0 Phone:.�iilb, ,./64,3Fax: i6 mg 53 g ! Email: /^ d 4 0.-c a0 co ty,c,/7- ,/te'F 'GENe. \LtcONTR4€TOJ 1NFOVIATION _ • :. Company Name:A t P1n,E A 1ixl 0,11)r _crd Address: P o -6 t Li l d City: h Lt!' S �' State A Zip: ci F06; Phone: 6 .1 q b got. 3 Fax: 20 C, ,;:)._ `i g- sly q Contr Reg No.:A LPt .1 ,e.L-(p 3pxp Date: S- 3 i_. 1 Z Tukwila Business License No.: H: \Applications \Forrm- Applic Lions On Line\201 I Applicat onslPermit Application Revised- 8- 9- 11.docx Revised: August 2011 bh King Co Assessor's Tax No.: '� Z 5-z-0 0 (7 ?s Suite Number: Floor: New Tenant: ❑ Yes 0 ARCHITECT OF RECORD Company Name: , Ae et Company Name: /yl e— , l E L •ri„1M4 68- re_ Ur �6,� Architect Name: ,/l1 „J. y 0,14_i., riot S t ✓ t Address: 7 � 7 F�ex Phon,9, 5-3 8g v�6 City: 6 I�ck 0 r G r ,State: J A Zip: Phone: 34,, 0 S60 i q gZFax: City: Email: State: ENGINEER OF RECORD Company Name: , Ae et Engineer Name: I"6 ...be.,t(t -rho Address: --11.40 3 y le /4.0€ oc.+4, City: A b H rn State: A Zip: 7PD0I 7"► 7 � 7 F�ex Phon,9, 5-3 8g v�6 Email: I"Cl. 11,0( pn ®e_,,r44'Ir, r. Is . r•e+ LENDER/BOND ISSUED (required for projects $5,000'or greater-per RCW 19.27.095) • Name: okow Address: City: State: Zip: Page 1 of 4 • BUILDING P.ERMIT INFORMATION —206 -431 -3670 ' • Valuation of Project (contractor's bid price): $ ' 000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 'G-Y f '�ioot^1 ccdcUTioi &Ail: IC �?VORKSiPFi ,r7,' T' � i �6 z 0179 ALION _ :206 = 433 = Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #I25 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View ❑ .. Renton CI ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ... Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund /Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H.\Applications \Forms- Applications On Line \2011 Applications \Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF TI-1E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NER OR .1 1 ORIZED AGENT: Signature: J qiY fig ' I (IP Print Name: ( -O �-�-N C.�� s \/F Mailing Address: 7 13 o k 1D HaApplications '.Forms - Applications On Line1201 t Applications\Permd Application Revised - 8 -9 -11 docx Revised. August 201! bh Date: 3— ]'1 —(? Day Telephone: ZIL 24C q 6 3 Sea 1-1.,s+ >AJ A 9 t ei Z City State Zip Page 4 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 8125200035 Permit Number: D12-086 Address: 5145 S 168 ST TUKW Status: APPROVED Suite No: Applied Date: 03/14/2012 Applicant: FITTERER & SPIKER ADDITION Issue Date: Receipt No.: R12 -01430 Initials: User ID: TLS 1670 Payment Amount: $1,225.58 Payment Date: 04/26/2012 12:45 PM Balance: $0.00 Payee: CATHY SPIKER - BRIAN FITTERER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1263 1,225.58 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,225.58 1,194.30 26.78 4.50 doc: Receiot -06 Printed: 04 -26 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 8125200035 Permit Number: D12-086 Address: 5145 S 168 ST TUKW Status: PENDING Suite No: Applied Date: 03/14/2012 Applicant: FITTERES & SPIKERS RESIDENCE Issue Date: Receipt No.: R12 -01056 Initials: User ID: Payee: JEM 1165 Payment Amount: $749.52 Payment Date: 03/14/2012 12:29 PM Balance: $1,225.58 CATHY SPIKER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1256 749.52 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - RES 000.345.830 749.52 Total: $749.52 doc: Receiot -06 Printed: 03 -14 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Pr ject: tt�`P 5P: key Ma, Type—o( of Inspecti n: , 6 ,, . �1�� Adder st 1 rKsr Date Called: Special Instructions: Date Wanted: i --- C(.151 + r p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 10/ %' /1.1,7/ kw-) I cAJc Dat R SPECTION FEE REQI4 1RED. Pridr to next inspection. fee must be id at 6300 Southcenterf lvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit 2_,O �}� INSPECTION NO. . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 oh_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 a9 Project...... -MI Lefier Type of 1 _ pectin • Addre s: Date Called: Special Instructions: Date Wanted: 23 -l3 .a.m.. Requester: Phone No: 7,9( -2-42 -- P2( r. L' pproved per applicable codes. Corrections required prior to approval. COMMENTS: • In pector: ,,�I gate: i 2 3 tEINSJECTION FEE REQUIREQ. Prior to next inspection. fee must be ail at 6300 Southcenter Blvd%, Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ; f. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • Project: F r r i - r . . A . E fk e S P _ r v f R Type of Inspection: vi'" _E,Jsza L iffl .LOS2,.1t4 1o,t.) - 4DpI v (; . Address: 'SIy5S1(..,8 sir` Date Called: is 10o 2 _LN5ti !A4I J - nppo \kci 'i Special Instructions: Date Wanted:. 12.- I-7 - I rid' I -1--N:2,/4 -E-"\J —tit /4 p.m. Requester: Phone No: 206.- 2- `i2. -c812. ) Ca.Approved per applicable codes. Corrections required prior to approval. COMMENTS: iffl .LOS2,.1t4 1o,t.) - 4DpI v (; . 0OI It'�.0 �A1s11LliIQ� - Ff�pi r�e) � r" 3) is 10o 2 _LN5ti !A4I J - nppo \kci 'i Sf it /a-4it -App f r-'17 rid' I -1--N:2,/4 -E-"\J —tit /4 Date: 2- 17 EIN PECTION FEE REQUIRED. Prior tdnext inspection, fee must.be ka'd'at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Q Type of Inspection: Fn PM . Fti rFR.4S%k Spit Address; 51`4 5 S i 6 6 s Date Called: Special Instructions: Date Wanted:. 16_Zy-IZ Requester: Phone No: (9.08_.2. -qa.- GI2_ I Approved per applicable codes. El Corrections required prior to approval. COMMENTS: //?'��,7f� /W,PdVe°c( ro Are Gtoz.,APer 4fipPettY DatQ: n R tNSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule .reinspection: - 5 . INSPECTION NO. INSPECTION RECORD Retain a copyr with permit, D/2 0,9 C.. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 - 2464 Project: ',., 1--.1 11"f , ?? i �S;'1 X82 Type of Inspection: j G414 I / -Cle4 /�jfry �' /534'0 ✓ Address: S/9- 5 /665 .$r Date Called: ,---"/ 2A ' i A/6. Special Instructions: Date Wanted:. 9 - / I - / a. 0 p.m. Requester: Phone No: X53- 3 s -A2_67 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A %- . • 0 ry ,;r- .54e4. 64,1y z)oth -_ &d I'1 /-e/,GI- rte/, - fipie%t. - or i TO 2 -I iejleel -4_, F /e' /,,i; r( RAL54- u.✓e� 1NSPFfCTION FEES REQUIRED. Prior to next inspectior♦;:fee•must p'aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule,reinspection. Date :. • ' - • INSPECTION RECORD • Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `g. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro' ct: Type of Inspection: s1 PCr l Add re `�� + _/� �v Date Called: Special Instructions: u \6c. C , 1� Date Wanted:. �/ . F'. -1 f L p.m. Requester: Phone 3 35.0 - 3 2 Approved per applicable codes. El Corrections required prior to approva . COMMENTS: Ok 7D Inspector: Date: Ag n REINSPEI�ION FEE REQUIRED. Prior to next inspection.. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. :. ai INSPECTION RECORD • 4 r at Retain 0 copy with permit °810 INSPE'CT(ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818`8. (z- (206) 431- 3670., Permit Inspection Request Line (206) 431 -2451 Pro cY �� JJ Type of Inspection: Address: ; ; S ( 454. I GS' sr- Date Called: Special Instructions: - Ao (:61\ • a Date Wanted:. k - c- "-- CI— cam) p.m. Phone No: ? S3-35O -3? L. Approved per applicable codes. Corrections required prior to approval. 3 Inspector: ❑ RE I ISPECTION FEE EQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 412-686, Project: fn7 FQ III Srli/1,:12 Type of Inspection: foOTi Al C' Address: s/ 4/ S' /65 - Date Called: Special Instructions: Date Wanted:. .Vg— /Z-- / p. Requester: Phone No: 02 .5,3 - 3se) • -32. 6 Approved per applicable codes. El Corrections required prior to approval. 4. COMMENTS: Inspec D : AAAP) / 14 - 't„LA—gt---i ./'7 17 --1.`"-77 • SPECTION FEE REQUI D. Prior to ext inspection..fee'must be id at 6300 Southcenter Blvd., Suite 100. salt to schedule feinspection. . INSPECTION 0. INSPECTION RECORD Retain a copy with permit PERMIT NO. 0 Y OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project!! � 1 -C +�. S� , f �\ Type of v J ' tL-u Inspection: r Lk "� 4 Cj Address: 415 Date Galled: Special Instructions: Date Wanted • _ 14 – (Z p.m. Requester: Ph e-13 —3.5-° 3 Ro 2_ Approved per applicable codes. 3 , Corrections required prior to approval. • COMMENTS: 6 V- (Ai tfL Inspector: Date: o — (+—(V n REINSPECTION FEE REQUIRI D1'rior to next inspection, fee must be paid at 6300 Southcenter'BTvd., Suite 100. Call to schedule reinspection. OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT Job Number: 12 -0363 Project: Fitterer / Spiker Residence Address: 5145 S 168th St, Tukwila Inspector: Jerry Graham Report Number: 132777 Permit Number: ‘1:,,A2-086 RECEIVED AUG 01 2012 Description /Location: Shear walls: perimeter Intended Use: Anchor Bolts • �',. Client: Fitterer and Spiker Address: 5145 S 168th St, Tukwila Date: 7/10/2012 Building Code & Year: IBC 2009 0 Reinforcing Steel ►4 All Thread Bar /Dowel Size & Quantity: Anchor Size & Quantity: 5/8" (5), 1" (5) Rebar Manufacturer: Type of Steel (ASTM): ►1 A -36 • A -325 • A-449 • Other: Rebar Grade: • 40 • 60 • Other: Type of Bar: • A -615 • A -706 • A -775 • Other: Special Ductile Quality (SDQ): • Yes • No Anchor Length: 24" Hole Depth: 9" and 12" Required Embedment: 9" and 12" Hole Diameter: 3/4' and 1 1/8" Concrete Thickness: Varies Concrete Strength: Existing Concrete Base Material: ►4 Normal Weight Concrete • Light Weight • CMU • Brick • Composite Deck Other: Compressed Air PSI: Hole Cleaning: ►4 Compressed Air • Hand Pump • Hole Condition: Brushed: ►1 Yes • No ► Dry • Damp • Water Saturated • Submerged No Approved Diamond Cored Drill Bit (ANSI B212.15): ►4 Yes • Hole: • Yes ►4 No Adhesive Type: Simpson Set XP Expiration Date: 3/2014 ICC ESR #: 2508 Weather: Cloudy Ambient Temperature: 58° Substrate Temperature: 55° Reference Standard(s) Used: Copies to: X Client X Engineer Owner X Contractor Architect X Building Dept. Others Comments Technical Responsibility: Conforms X Does Not Conform 4041Jeff Ra be Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 -4600 or 1- 888 - OTTO -4 -US - Fax (206) 723 -2221 Form No.: ADMIN -86 -01 (Rev 09/09) SOUTH 168TH ST. PROPERTY- - LINE-TYP. FILE' EXISTING LOT COVERAGE IS 14.72 INCLUDING EX. GARAGE & HOUSE & FRONT PORCH FOOTPRINT = 1425.0 S.F. _ _ (DIMED.B!.LLOTA1EB :._ ._ = 9Zii.. S.E. ALSO: EX. IMPERVIOUS LOT COVERAGE IS 27.5% bIHICH INCLUDES EX.GARAGE 8 HOUSE & EX. FRONT PORCH FOOTPRINT AND EX. B CK D CK & .DRIVEWAY = 267 .1 S.F (DIVIDED BY) LOT AREA = 9711.0 S.F. b1.1-08f9 IEX. NE4S EXISTING 02/15/2012FWD1 111143E1E6I 03 /q8 /20112FWD /ENG THUSLY: THERE ISiD (0.0 %) LOT COVERAGE INCR THE FRONT YARD COVERAGE IS 28.3% AND REMAINS WITH ° N0° INCREASE .PROPERTY CORNER —TYP. tN 58.33' � o• ECM' APR 16 201 •4' -� f PARCEL #8.12520 -0035^ ZONING: LDR 'LOT LOT 3' LEGAL DESCRIPTION: SCALE; 1° = 20.0' SUNRISE VIEW UNREC LOT 4 OF CITY OF TUKWILA SHORT PLAT NO 81 -17 —SS RECORDING NO 8201200034 SD PLAT DAF —BEG NW COR OF SW 1/4 OF SEC 26 -23 -04 TH ALG W BDRY SD SUBD S 0 -48 -39 E 125.54FT TH PLT N BDRY SD SUBD S 89 -21 -31 E 396 FT TO TPOB TH CONTG S 89 -21 -31 E 436 FT TH S 0 -48 -39 E 95.54 FT TH N 89 -21 -31 W 436 FT TH N 0 -48 -39 W 95.54 FT TO TPOB AKA TRAC F BACK; SUNRISE VIEW ADD UNRft� r 1 11014 KING CO.,WA LTR# PROPERTY OWNER AND ADDRESS: LINES— CATHY J. SPIKER & BRIAN FITTERER 206- 242 -8121 5145 SOUTH 168TH STREET, TUKbWILA, WA 98188 c• EASEMEN T FOR ACCESS TO LOT 3 & 4 EX. HOUSE EX. DECK 20.0'x 12.0 51.0' NEW DECK 101.67' 89 °21 °31 °E r MDT ENGINEERING FILE COPY Permit No.. .. • . .. -1 � - Nam tt 31403 44th Avenue South Auburn, WA 98001 253 - 887 -8725 md.thompson@earthlink.net Structural Calculations For the Spiker /Fitterer Addition 5145 S. 168th St. Tukwila, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of BUILDING � Tukwila DIVISION March 6, 2012 crrOigAILA MAR 14 2012 PERMIT CENTER • Obili • D12- Building Official: Please accept this engineering packet only with a wet stamp and only for the site noted above. MDT ENGINEERING 31403 44th Avenue South Auburn, WA 98001 253 - 887 -8725 Table of Contents Page No. Scope of Work Structural Notes ii Shearwall Schedule iii Structural Details v - Lateral Analysis 1 — 6 Vertical Analysis 7 - 10 MDT ENGINEERING 31403 44th Avenue South Auburn, WA 98001 253 - 887 -8725 md.thompson @earthlink.net Scope of Work MDT Engineering was asked to provide structural calculations for the addition to the existing structure. The following items are included: 1. Lateral Analysis with Basic Wind Speed = 85 MPH, Exposure B 2. Vertical Analysis with 25 PSF Snow Load We have provided the designer with 2 copies of the structural plan and details for his use in obtaining a building permit for the referenced project. The scope of this project is for the design phase. If additional site inspections are required by the Building Dept., these will be performed at an additional hourly fee of $100.00 per hour. Also, revisions to the original design by the owner or required by the building department will be billed at an additional hourly fee of $100.00 per hour. Questions about the attached information should be addressed to MDT Engineering. Michelle D. Thompson, PE MDT Engineering, Inc. STRUCTURAL NOTES_ CODES AND SPECIFICATIONS I. INTERNATIONAL .BUILDING.CODEi 2009 EDITION; ASCE 7-05. 2. INTERNATIONAL RESIDENTIAL CODE, 2004 EDITION SIMPSON. STRONG-TIE CONI‘IECTORS-AND-ANCHOR SYSTEMS- CATALOCa.20.07 4.- FASTENERS IN.CONTACT. WITH.PRESSURE TREATEDE WOOD MUST BE STAINLESS STEEL, ZMAX (G185HDG PER ASTM A653), BATCH/POST HOT-DIP GALVANIZED (PER ASTM B695, CLASS 55 OR GREATER). UNCOATED AND PAINTED PRODUCTS SHOULD NOT BE USED WITH TREATED WOOD. WHEN USING STAINLESS STEEL HOT- DIP GALVANIZED CONNECTORS, THE CONNECTORS AND FASTENERS s.HouLp BE MADE OF THE sAmF .mATFRIAL, DESIGN CRITERIA 1. WIND LOAD INTERNATIONAL BUILDING CODE - 2001, ASCE 7-05 SIMPLIFIED METHOD, BASIC WIND SPEED - 85 MPH, EXPOSIJIW B 2. SEISMIC INTERNATIONAL BUILDING CODE - 2009, ASCE 7-05. SIMPLIFIED ANALYSIS, SEISMIC DESIGN CATEGORY D, I = 1.0 3. ROOF LOAD DL =15 PSF = 47,6 W3f 4. FLOOR LOAD DL= 10 PSF LL = 40 PSF 5. DECK LOAD DL =10 PSF LL =40 PSF 6. SOILS. ASSUMED 1500 PSF ALLOWABLE SOIL BEARINJG ASSUMED 30 PCF EQUIVALENT FLUID PRESSURE fog,RFTAININg WALL DESIGN 7. CONCRETE 3000 PSI @ 28 DAYS (2500 PSI USED FOR DESIGN) GRAD E 40 REINFoKEKRNT MINIMUM 3" COVER FOR ALL REINFORCEMENT EXCEPT AS NOTED AT RETAINING WALLS OR OTHER DETAILS 8. MORTAR TYPE S TIMBER CONSTRUCTION NOTES 1. LUMBER GRADES AND ALLOWABLE STRESSES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON PLAN: ALL LUMBER, UNLESS NOTED OTHERWISE GLULAM BEAMS 13/4" MICROLAM, LVL 2 11/16 ", 3 ' /2 ", 5 'A" & 7" PARALLAMS, PSL HEM -FIR #2 OR BETTER 24F -V4 Fb =2400 PSI E = 1800 KSI Fb =2600 PSI E = 2000 KSI Fb =2600 PSI 2. WHEN TOP PLATE IS INTERRUPTED BY HEADER, HEADER SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE EACH END. USE 2- SIMPSON MSTA24 CONNECTORS, UNLESS NOTED OTHERWISE. 3. ALL SHEAR WALL SHEATHING NAILS AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND AS NOTED IN THE SHEAR WALL SCHEDULE. 4. FLOOR AND ROOF DIAPHRAGM NAILING SHALL BE 8d COMMON @ 6" O.C. AT ALL SUPPORTED PANEL EDGES AND 8d @ 12" O.C. AT INTERMEDIATE SUPPORTS. SOIL CONSTRUCTION NOTES 1. ALL FOOTINGS AND SLABS SHALL BEAR ON UNDISTRUBED SOIL OR FILL COMPACTED TO 95% MODIFIED PROCTOR 2. ASSUMED ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF GENERAL CONSTRUCTION NOTES 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY VARIATIONS FROM THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR THE ENGINEER. 2. ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION SHALL BE PROVIDED. ANY PROPOSED FIELD CHANGES MUST HAVE THE APPROVAL OF THE ENGINEER PRIOR TO CONSTRUCTION. '1 , L ALL FASTENERS SHALL MEET THE FOLLOWING CRITERIA: 0J3I DIAX 2 1/4' Mt 0148" DIA X 7 1/1" MW, Ibd toMMDN • 0.1616 DIA X 3 1R" MN, Sd COOLER • 0,056' PIA X 15/8' MIN, 8d GUIB • 0092" DIA X 1 3/4' MIN, I5GA STAPLE o 0012° P14 x 1 1/7" not 14 GA STAPLE .0.080 DIA X 1 112' MILL 2. ALL APA RATED SHEATHING AND SIDING AND PANEL EDGES SHALL BE BACKED WITH 2 NCH NOMINAL O1R WIDER FRAMING AND FASTENED PER THE SCHEDULE ABOvE. PANELS MAY BP METALLED EITHER HORIZONTALLY DR VERTICALLY. SPACE NAILS At 12' QL- OR STAPLES AT 10" oc- ALONG INTEtd1EDIATE PRATING MEMaER8. 3. PRo'IDE ALL ANc140R BOLTS WITH 3 "X3 "10/16' PLATE WASHERS. 4_ AT GARAGE JAMBS, REFER TO LATERAL RESTRAINT PANEL DETAIL '40L 6- PROVIDE 1/16" MIN, APA RATED SHEATHIN3 (PLYWOOD OR OSB) OR APA RATED SIDING 503 OR INNER SEAL OSB RATED PANEL BIDING ON ALL E)CTERIoR WALLS DESIGNATED A8 6WEARIIALLS. 6. WHERE PANELS ARE APPLIED ON BOTH SIDES OF A WALL AND NAIL SPAC51 15 LESS THAN 6" DC. ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEhIBER 5 OR FRAMING SHALL BE 3" NOMINAL OR THICKER AND NAILS ON EACH SIDE SHALL BE STAGGERED. 1. REFER TO TYPICAL BHEARUALL DETAILS FOR LOCATION OP. R3A 1ING ANci-ORS. B. AT INTERIOR BHEARWALLB AT ROOF PARALLEL TO THE TI9J55E8, REFER TO DETAIL.3>IBk TIE SHEARWALL TO ROCF TR136 WITH FRAMING ANCHORS SPACED PER SCHEDULE OR EXTEND 6HEARWALL TO ROOF AND SHEATH AND FASTEN PER 81•IEAR)1JALL TYPE GALLED OUT 6ELOW 9. ALL FRAMING MEMBERS REGEMNG EDGE NAILING FROM ABUTTNa PANELS SHALL Nor BE LESS THAN A SINGLE 3X MEMBER • SI4EARJIJALL TYPES 3,4, AND 5. FOR EXAMPLE, PROVIDE A 3X STUD AT VERTICAL JOINTS IN THE SHEATHING. 10. FOUNDATION SILL PLATES AND BOTTOM PLATES OP BWEARWALL SHALL NOT BE LESS THAT A SINGLE 3X • MEMBER • 8WEAIRLUALL TYPES 3,4, AND 6. ALSO, PROvIDE A 3x MINIMUM WIDTH MEMBER BELOW SHEARUALL TO REGEIvE LAG ScREW6 BUCK AS A 3x RIM JDIrT, 3x JOIST BELOW SWEARIIALL OR 3x BLOCKING BELOW 6HEARWALL a BHEARUALL TYPES 3,4, AND 5. 11. FASTENERS AT PRESSURE PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SMALL BE STAINLESS STEEL, GIBS HDG, BATCH/POST HOT -DIP GALYANIZEO OR MECHANICALLY GALVANIZED. r1ARk SHEATHING (NOTE 5) • • FASTENER SPACING - e ALL EDGES • (NOTES It 111J ', BOTTOM PLATE ' NAILING OR ANCHOR ®OLTII • ', • (NQTE'3) . FRAMING -- ANCHORS . (NOTES !T, '8) - - 41:Lau: - . AOLE SHEAR - NoIE6 IA 1/16' hIN. APA RATED SHEATHING OR • APA RATED SIDING 503 .13I'XI -1 /4" MIN. a 6'. OrC.-.: OR . 14 GA ei 6" O,C.. 161'x3 -14" MIN, • S" OL opt. 1R' AB r 6' -I," OD. ,.. 433 • 7' -4" O.E. or.' :IZ Iv °. ' 130 PLF 2 1/16" MIN. APA RATED SHEATHING OR APA RATED SIDING 303 .191')0 -1/4" MIN. • 6" 04.• OR : ' . 14 GA. a 0 ". OG, J6V)0 1Q' MN, • 6" Of OR I/7? AB a 3' -2" oc. oR 5/5" 48 o .4' -6" QC. A35 . I'- 6`.00. D52 ROC • 130 Pli 2 1116" MIN. APA RATED SHEATHING OR APA RATED SIDING 309 J3rx2 -u4' MIN. •4'0:C. OR 14 GA, 84" OJT ,161 "X3 -V1" MIN • 4' o.C,.OR V!' 48 a 7'4' 0,0, OR 5/8" AB • 3'-0' O.C. A35 e.l'•0' DL. OIZ. iP}C • 350 PLF 1 1/16' MN, APA RATED SHEATHINGS OR APA RATED BIDING 303 13rx2 -I/4" MIN. • ' Oa OR • 14 GA e 0° O.C. 1/450' LAG 6C1t8J 01' MGR . VP AB • I'-6" OL, OR 5/8" A0 a 2' -4° O.G. A)5 I I@' OC. pg. tzza. 451 PLF 2, 4, 9,10 4 -^ VU6' MIN. APA RATED SHEATHNG OR ,..APA RATED SIDNG 903 .148"X2-IR" MN. • 3' O,C. OR 14 GA. i 2 -1/2" O.C. IMO' LAG MO i 6' 0.C. OR V1' AB • 11•4' OL, OR • me AS • 2'-0' oe A35 • 8" OL pjz psod, 545 PLF 2, 4, 9,10 5 1IIb° MN, APA RATED AHEATNNG BOTH SIDES ,,, J31'X2•V4' MDL 4 3' O;C- OR n 14 6A. a 9 OG U496' LAG SCRES • 3' DC OR 5/0' AB « p.2" oe. A39 • 6' OC. b IZ R ��:. 501 PLF 2,4,6 9,10 '1 , L ALL FASTENERS SHALL MEET THE FOLLOWING CRITERIA: 0J3I DIAX 2 1/4' Mt 0148" DIA X 7 1/1" MW, Ibd toMMDN • 0.1616 DIA X 3 1R" MN, Sd COOLER • 0,056' PIA X 15/8' MIN, 8d GUIB • 0092" DIA X 1 3/4' MIN, I5GA STAPLE o 0012° P14 x 1 1/7" not 14 GA STAPLE .0.080 DIA X 1 112' MILL 2. ALL APA RATED SHEATHING AND SIDING AND PANEL EDGES SHALL BE BACKED WITH 2 NCH NOMINAL O1R WIDER FRAMING AND FASTENED PER THE SCHEDULE ABOvE. PANELS MAY BP METALLED EITHER HORIZONTALLY DR VERTICALLY. SPACE NAILS At 12' QL- OR STAPLES AT 10" oc- ALONG INTEtd1EDIATE PRATING MEMaER8. 3. PRo'IDE ALL ANc140R BOLTS WITH 3 "X3 "10/16' PLATE WASHERS. 4_ AT GARAGE JAMBS, REFER TO LATERAL RESTRAINT PANEL DETAIL '40L 6- PROVIDE 1/16" MIN, APA RATED SHEATHIN3 (PLYWOOD OR OSB) OR APA RATED SIDING 503 OR INNER SEAL OSB RATED PANEL BIDING ON ALL E)CTERIoR WALLS DESIGNATED A8 6WEARIIALLS. 6. WHERE PANELS ARE APPLIED ON BOTH SIDES OF A WALL AND NAIL SPAC51 15 LESS THAN 6" DC. ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEhIBER 5 OR FRAMING SHALL BE 3" NOMINAL OR THICKER AND NAILS ON EACH SIDE SHALL BE STAGGERED. 1. REFER TO TYPICAL BHEARUALL DETAILS FOR LOCATION OP. R3A 1ING ANci-ORS. B. AT INTERIOR BHEARWALLB AT ROOF PARALLEL TO THE TI9J55E8, REFER TO DETAIL.3>IBk TIE SHEARWALL TO ROCF TR136 WITH FRAMING ANCHORS SPACED PER SCHEDULE OR EXTEND 6HEARWALL TO ROOF AND SHEATH AND FASTEN PER 81•IEAR)1JALL TYPE GALLED OUT 6ELOW 9. ALL FRAMING MEMBERS REGEMNG EDGE NAILING FROM ABUTTNa PANELS SHALL Nor BE LESS THAN A SINGLE 3X MEMBER • SI4EARJIJALL TYPES 3,4, AND 5. FOR EXAMPLE, PROVIDE A 3X STUD AT VERTICAL JOINTS IN THE SHEATHING. 10. FOUNDATION SILL PLATES AND BOTTOM PLATES OP BWEARWALL SHALL NOT BE LESS THAT A SINGLE 3X • MEMBER • 8WEAIRLUALL TYPES 3,4, AND 6. ALSO, PROvIDE A 3x MINIMUM WIDTH MEMBER BELOW SHEARUALL TO REGEIvE LAG ScREW6 BUCK AS A 3x RIM JDIrT, 3x JOIST BELOW SWEARIIALL OR 3x BLOCKING BELOW 6HEARWALL a BHEARUALL TYPES 3,4, AND 5. 11. FASTENERS AT PRESSURE PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SMALL BE STAINLESS STEEL, GIBS HDG, BATCH/POST HOT -DIP GALYANIZEO OR MECHANICALLY GALVANIZED. FOOTING SCHEDULE MARK SIZE DEPTH REINFORCING ALLOWABLE LOAD 18 18 "x18" 8" 2#4 each way 3375# 24 24 "x24" 10" 3#4 each way 6000# 30 30 "x30" 10" 3 #5 each way 9375# 36 36 "x36" 10" 3 #5 each way 13500# 42 42 "x42" 10" 3 #5 each way 18375# 48 48 "x48" 12" 4 #5 each way 24000# 54 54 "x54" 12" 5 #5 each way 30375# 60 60 "x50" 12" 5 #5 each way 37500# 66 66 "x66" 12" 6 #5 each way 45375# 72 72 "x72" 12 " 7 #5 each way 54000# Note: Footing design is based on 2500 psi concrete and an allowable soil bearing pressure of 1500 psf. I. (2) 7x STUD5 2. 2X TREATEP;PLATE, FIEL. VERIFY.ANC({OR •E3OLT5`. PER 5I- lEAROL:L`,SGyEDU oR EXPANSION- ANGI: -10R5: T MEET. SfAGING': 3. IF REG?LIIREI ,• HOLDOU I :P PLAN. DRILL: AND: EFOXY THREADED ROD TO EXIS. FOUNDATION; SIZE AND EMI3EDMENTDEPTI -I PER 4. EDGE NAILING ! BOTTOM PLATE AND SILL PLATE Jim i 5. EXISTING: 'FOUNDATION TYP. SHEAR LUAU. DETAIL. : EXIST INCA POUNDAL ION WALL. 3/4" SCALE I. BOTTOM PLATE NAILING PER 61-1EARIJALL SCHEDULE 2. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 3. 2X STUD WALL 4. EDGE NAILING PER SHEARWALL SCHEDULE 5. SIMPSON STRAP PER PLAN. CENTER ON RIM JOIST. (AT NT. WALL SLOT PLYWD.) 5IMPSON FRAMING ANCHOR PER SHEARWALL SCHEDULE (NOT REQUIRED IF PLYWOOD JOINTS ARE LOCATED AS SHOWN ON THIS DETAIL). TYPICAL SHEAR WALL DETAIL. WITH WALL BELOW 3/4" SCALE L USE TOP PLATE NAILING PER SHEARWALL SCHEDULE 2. SIMPSON FRAMING ANCHOR PER SHEAR WALL SCHEDULE 3. EDGE NAILING PER SHEARW'ALL SCI- 4EDULE .4. SHEATHING AND NAILING PER 5HEARWALL SCHEDULE AND PER PLAN 2m2 fYi. INT. SHEAR WAL DET4IJ. WITH NO SHEAR WALL A 3OVE 3/4" SCALE L BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE 2. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 3. SIMPSON .STRAP PER PLAN. SLOT PO-IUD. AND BEND STRAP g JOIST OR BLOCKING 4. EDGE NAILING PER SHEARWALL SCHEDULE IF JOISTS ARE PERPENDICULAR TO SHEARWALL PROVIDE (2) 2X BLOCKING BETWEEN JOISTS FOR FULL LENGTH OF SI-EARWALL IF JOISTS ARE PARALLEL TO 61-IEARIUALL PROVIDE DBL. JOIST UNDER SI- IEARWALL TYP. INT. SHEAR WALL DETAIL w I ti NO SHEAR WALL BELOW 3/4" SCALE I. SNEATNING AND NAILING PER SHEARIIJALL SCHEDULE 2. BOTTOM PLATE NAILING PER SNEARI1ALL SCHEDULE 3. Sd g 6" O.G. AT EACH JOIST IN CANTILEVERED PORTION 4. Sd s 6" ON CENTER 5. A35 SIMPSON FRAMING ANCHORS PER SHEARWALL SCHEDULE OR A35F ANCHORS ON OUTSIDE FACE SHEAR TRANSFER DIt4I1. CANT I LEYMIRMD JO I Sts 3/4" SCALE • I• PAR PLAN. 2. SIMPSON 1H2.5' AT EACH TRUSS 3. ROOF SHEATHING 4. 2X BLOCKING W /Bd e 6" O.G. 5. SNEAK/ALL NAILING PER SCHEDULE 4,, gee. Cu P6 pe vt .1^ . "6-17L.)4-6 PERIMETER SHEAR TRANSPER DETAIL EXTERIOR BkEARWALLS 3/4" SCALE • 1 SHEATHING AND NAILING PER 5I-IEARWALL SCHEDULE AND PER PLAN • 2. SIMPSON 'A35' FRAMING ANCHORS • PER 5NEARWALL SCHEDULE 3. BcI NAILS 6" ON CENTER NOTE: PROVIDE SHEATHING AND NAILING PER &I-IEARWALL SCHEDULE GABLE ENID 14-012_1WA/774-C.- JO"-ti 6/-Wiler717.A./c1 AE2okle". (ir Afe2 dbp-&ierp-miel ,t/An oe,:2ve Afeetwi. kkl A-ce- A107 - .PW.' (7) DETAIL. 3/4" SCALE MDT Engineering, Inc. kla,1 Lateral Analysis Wind Design: From Figure 6 -2 Per 2006i IBC and ASCE 7 -05, Sect. 6.4 Method 1 Simplified Procedure Wind Speed = 85 MPH Exposure B This factor varies on mean height and exposure category H = 30' or Tess H = 35' or Tess H =40'orless Height and Exposure Factor = 1.0 Height and Exposure Factor = 1.05 Height and'Exposure Factor = 1.09 31403 44th Ave. S. Auburn, WA 98001 253 -887 -8725 (Fax) 253 - 887 -8672 Horizontal Wirid Loads: From Figure 6 -2 These Toads vary based on wind speed, roof slope and height and exposure factor. These are the maximum values for any roof slope. Ps= HEF x Kzt x 1 x Ps30 Zone A= 1.Ox1.Ox1.Ox15.9= 15.9PSF Zone B = 1.0 x 1.0 x 1.0 x 8.8 = 8.8 PSF Zone C= 1.0 x 1.0 x 1.0 x 10.6 = 10.6 PSF Zone 0 =1.0x1.0x1.0x7.0= 7.0PSF For Horizontal Design Loads, use the maximum load of 15.9 PSF in all zones and directions. MDT Engineering, Inc... Lateral Analysis Seismic Design: Fa = 1.0 Per 200q IBC and ASCE 7 -05, Sect. 12.14 Simplified Alternative Structural Design Soil Site Class D Occupancy Category 1, 1= 1.0 Ss ='1.5 Fv 1.5 S1 = 0.5 Sml =FvxS1 = 1.5x0.5 =0.758 Sds = 2/3 x Fax Ss= 2/3 x 1.0 x 1.5 = 1.0g Sd1 =2 /3xSml = 2/3x0.75 =0.5g From Table 11.6 -1, Seismic Design Category D V�(FxSdsxW) /R V= (1.2x1.OxW)/6.5 V= 0.1846 x W 31403 44)h Ave. S. Auburn, WA 98001 253 - 887 -8725 (Fax) 253- 887 -8672 W = Dead Load R = Response Modification Factor R = 6.5 for Tight frame walls with wood shearwalls F = 1.0 for 1 story F = 1.1 for 2 story F = 1.2 for 3 story CoMPP\KE eEts_KMSPss_F5V1 -- WiND U5E,MAX.WINI>LOAp 0F/6.9 PsiF IN NI. biREVIDIQS Viasx= 1.2-Om • 11.54145M. i . . • • ' • • • • • ; Pt • (*)-- c;r 4so • iqo ep64-.) .„00 •ii4,0sof Of..1641cep (40: ) ap 1,14.:7,14p4r: ; 12,6toolup aki MDT Engineering Consulting Structural Engineers 31403 44th Ave. S. Auburn, WA 98001 253 - 887 -8725 Wind Load 15.9 SW# Width Height Total Shear Wall Length Total Wall Length Shear Per Foot SW Type 1 10.5 10.75 1795 10.50 10.50 21.00 85 1A 2 10.5 10.75 1795 18.50 5.00 23.50 76 1A 3 14.5 10.75 2478 2.50 2.50 5.00 496 4 4 15.5 10.75 2649 5.50 5.50 11.00 241 2 5 10.75 10.5 3589 25.00 25.00 144 1 6 10.75 10.5 3589 17.00 5.50 22.50 160 1 7 12.5 10.75 4615 15.00 3.00 18.00 256 2 8 12.5 10.75 4786 1.50 1.50 1.50 4.50 1064 5 ME Graphics Spiker - Fitterer Addition MDT Engineering Consulting Structural Engineers 31403 44th Ave. S. Auburn, WA 98001 253 - 887 -8725 SW Shear Per Foot Length (feet) Total Shear (Ibs) Dead load (Ibs) Wall Height (feet) Gross Uplift (Ibs) Net Uplift (Ibs) Holddown/ Strap 1A 85 10.5 892.5 150 9.5 807.5 20 NEGLECT 1B 85 10.5 892.5 150 9.5 807.5 20 NEGLECT 2A 76 18.5 1406 150 9.5 722 -666 NO UPLIFT 2B 76 5 380 150 9.5 722 347 NEGLECT 3A 496 2.5 1240 150 9.5 4712 4525 M'ir.'0 3B 496 2.5 1240 150 9.5 4712 4525 MQ QO 4A 241 5.5 1325.5 150 9.5 2289.5 1877 ti e.,4, S3 4B 241 5.5 1325.5 150 9.5 2289.5 1877 4g-re4v 3 5 144 25 3600 150 10 1440 -435 NO UPLIFT 6A 160 17 2720 150 10 1600 325 NEGLECT 6B 160 5.5 - 880 150 10 1600 1187.5 NvU 2 7A 256 15 , 3840 150 10 2560 1435 1412 0/2_, 7B 256 3 768 150 10 2560 23351) 2 8A 1064 1.5 1596 150 10 10640 10527.5 H12U /4 8B 1064 1.5 1596 150 10 10640 10527.5 ' -jyL/ / It 8C 1064 1.5 1596 150 10 10640 10527.5] U /4 date 5h 2 project kt6r page ,,-N1 - 56¢(:). rP n0C Iwo )90 � mil ' (4'C) , .lQ� p1 /, 414- - ' P_cp 17� - 42&;2_7--- / _1 date *// project 6121 page t r . . w _ `'�( +- 0 FC. (4-C)) 4- 1 Lts 1 E L i E 1 I I I I I ; ! I i I I , 1 1 ! i 4 _t_ fri ! f 1 ! 1 1 date project 61 page T - _... -. ) 447 ,e, LJ Glie2x/ v\i /1"-/Pc.- v\i/2_-- ,(40) /e0176r P eefr i i I i 1 1 I i 1 - �---�� I i I I i I I 1 1 1 1 1 . i 1 D_E 1 I /I I-I_J - +41 I v f IJ 1 I 1 s _ I -1- i i i i 1 11- ( �- I i 1 l I 1 44e? I - - -1 i I 1 I -- I 1 1 I ; I I I 1 i 1 1 1 [ 1 1 - 1 r I 1 1 I 1 --r —1 f 1 -{-- , t { i I -date project 6pj frirmege_ page 1l 4-- 19O VJ w' SCE P&P e0p 44z 520 /- �� )k2J---. 8e0 12, 06 -03 -2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director GREG HUGHES PO BOX 410 SEAHURST WA 98062 RE: Permit No. D12 -086 FITTERER & SPIKER ADDITION 5145 S 168 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun fora period of 180 days. Your permit will expire on 07/22/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 07/22/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D I2 -086 6300 Southcenter Boulevard, Suite # 100 • Tukwila, Washington 98188 - Phone 206 - 431 -3670 • Fax 206 -431 -3665 April 6, 2012 • « City of O, Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Greg Hughes PO Box 410 Seahurst, WA 98062 RE: Correction Letter #1 Development Permit Application Number D12 -086 Fitterer & Spiker Addition — 5145 S 168 St Dear Mr. Hughes, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Departments. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, hall cian en File No. D12 -086 W:\Permit Center\Correction Letters\2012\D12 -086 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Gilding Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: Fitterer & Spiker Addition Permit #: D12 -086 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads as applicable. The current codes for decks have specific requirements for deck ledger attachments. Provide details with specifications for the deck ledger attachment. (2009 IRC TABLE R502.2.2.1 & R502.2.2.3) 2. The code notes make reference to the Carbon Monoxide detectors. Show the location on the plans for the CO detectors located outside of each separate sleeping area in the immediate vicinity of the bedrooms. Where there appears to be a door separation the two hallways up stairs, two shall be required. (SECTION 8315 Washington State Amendments) 3. Dwelling/garage fire separation shall be provided in the garage on post, beams and walls supporting of the upper structure with not less than 1/2 -inch gypsum board or equivalent. Show these elements provided with the fire separation and protection as required. (R302.6 & TABLE R302.6) Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. PENT GO • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -086 DATE: 04 -16 -12 PROJ.E,C.T NAME:.. FITTERER & SPIKER..ADDITION • �,, ; .. S'ITE'ADDRESS: 51'45 S 168 ST Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: 14- 'vision Fire Prevention Public Works Structural n Planning Division Permit Coordinator n 0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04 -17 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Idl Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 05-15-12 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 •PERMIT COORD COO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -086 DATE: 03/14/12 PROJECT NAME: FITTERER & SPIKER ADDITION SITE ADDRESS: 5145 S 168 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ildli ilvislon 1 ® Fire Prevention Pl"annin"g' Division ICI u lic orks Structural Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 03/15/12 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/12/12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments)l Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 014 D1I I / � Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 City of Tukwila Department of Conumunity Dertiopmeffi 6300 &altimeter ileulevard. Suite 1100 Tuktvikt. ushingtan 98188 Aux: 106-431.10 Far 206-431-3665 Web ik fafililryitatdoix ResLeion ssitisittals mast he st. &mimed k persos m Ike Permit f'eturs. Rerkiopn riff not ix, (templet MmHg* the ms14 fas, eft. are 4-119 Pbn °fedi/Permit Number: . D I 2-086 WWII' 'I WWI Repist to Corration We. 1 _ O Rev. ision after Penult is lamed o Bey iiion requested by a City Building Inspector or Plans Esainii ter • Projeat Address: 5145 S 168 St contact Pawar. (RFG HUSHFS Pbuse Numbbn 206-2i6-4063 &mum"' Revidual 4DADDRESSEDJULDI. ENG._ _DETAIL---#1014-11AS-BEEN ADDED TO SHEET S-1. OF SHE .STRUCTURALIOTFR 11AUESLAnD #21— En.m_."UPRELELDOICON SHEET 1 —0E-5—A8—PER GHL I GHT I NG . AND AL$Q NOTEILIALSHEECOCE.UOTE #14 #3)4401F_CORRECTED-01*-44414-F-LOOR-P-LAW---ON-REE-T-4-0E-5—AND--6-: W B . ADDED GARAGE-444L-4-- TO SHEET 3 OF nittaavea anfoFTuxweA APR 11 6 20121 PERNIRCENTER SECTIONS AS PER HIGHLIGAOING. IMIIIMINI••••••••".. #2.1.13. ABOVE pER M.F VF1 TilAUSEV2."EDESIGNER*** Mgt Plumber(s): 'Omer or bightigit all arras if rerivioa Received a the City oeTukwilr Permit Conger hy• in Perini% Pim _ jWO ca.-E-Aggla mutt mtImmal Cigna $-Ii-Mut Contractors or Tradespeople Pryer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ALPINE RIDGE CONSTRUCTION INC UBI No. 601246473 Phone 2062464063 Status Active Address Po Box 410 License No. ALPINRC103K2 Suite /Apt. License Type Construction Contractor City Seahurst Effective Date 5/22/1990 State WA Expiration Date 5/18/2014 Zip 98062 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HUGHED*206PP HUGHES DEVELOPMENT CORP, THE Construction Contractor General Unused 10/17/1980 10/2/1992 Archived Business Owner Information Name Role Effective Date Expiration Date HUGHES, LINDA P Agent 05/13/2010 Amount HUGHES, LINDA P President 01/01/1980 INSSE4120 HUGHES, GREGORY A Vice President 01/01/1980 OLES MORRISON & RINKER Agent 01/01/1980 05/13/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC 5E4120 05/18/2002 Until Cancelled $12,000.00 05/17/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 Contractors Bonding & Insuranc INSSE4120 05/18/2011 05/18/2013 $1,000,000.0003 /30/2012 10 CBIC INSSE412009 05/18/2010 05/18/2011 $1,000,000.0005 /13/2010 9 CBIC INSSE4120 05/18/2008 05/18/2010 $1,000,000.0005 /15/2009 8 CBIC INSSD4120 05/18/2002 05/18/2008 $10,000,000.0004 /16/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 04/26/2012 EX. 12/12? 'PITCH .(NEV TO MATCH EX.) EX. 5/12 ?PITCH (NEW TO MATCH EX.) A (IT LTP NEW ' C. RM, PL-i, REMODELED, GAS VENT CN:85,81 88.96 NEW REC.RM PL EX. 5/12 PITCH NEW REC.RM PL a UD N. • QD UJ EX.UPPER PL •1 EX. 12'x18' SCREENED /LOUVERED ATTIC AIR. VENT EX.UPPER PL NE1' NEV DOWNSPOUTS J LLJ O W W NEW REC.RM FL EX.UPPER FL-1 • EX.UPPER FL NEW P.T.4x4x36' W /LAG 3- 1/2'6x8' SCREWS INTO SOLID BLOCKING a EX. STUD VALL. • • W EX.MAIN PL -- EX. MAIN PL EXISTING a 0 1 00 W EX. MAIN FL .EX.DECK 4EXMAINFL EX.1' -4 EX.DECK EX.STEPS NEV POSTS P.T. 8 FOOTINGS f.EX PATIO WEST ELEVATION 1 /4' =1' -O' INSPECTION FOR VERIFICATION OF DRILLED HOLES AND HOLE PREPARATION FOR EPDXY SHALL BE REQUIRED PRIOR TO INSTALLATION OF EPDXY AND RE -BAR (OR BOLTS IF APPLICABLE). INSPECTION SHALL BE INCLUDED WITH FOUNDATION OR CONCRETE INSPECTION. 10' -6' -- -- i REVISIONS No charges shall be made to the scope of work without prior approval of tee Vila Building Division. .v:sions will require a new plan submittal niu j include additional plan review fees. ti EX.3'0'x3'0'SLIDER GARDEN WINDOW EX.3'013'6' EX. DECK 20'0'x12'0' EX.'5'O'x6'8' SLIDING GLASS DOOR NEW 4x4 P.T. POST W /18'x18'x8' FOOTING W /SIMPSON EPB44 HDU2 V/5/8'6 T.R. DRILL & EPDXY EMBED .9' EXISTING 25' -0' ��.EX.4' CONCRETE FLOOR! sc W LID EXISTING' G RAGE 20'4'x24 4' x6 POST FOR 'UPPE FL 00 R JOIST BEAM NEW 8y0 '0' O DOOR, •l I►1 STYiE I' reN EX. EX.F 4x6 POST FOR 'RIDGE BEAM' ' 4x6 POST FOR UPPER FLOOR JOIST BEAM 5!'8' PE X GWB 01F CEILING 0 SIM R ., II NEW'8'0 OV ' H DOOR Pp OWNE 0' it‘MT/ � y I EX. LAI'NDRY ' \ 8'8'x9'8- 7 EX. KITCHEN 9'4'x10'0' X. SELF - CLOSING ()SMOKE DETECTOR SOLID CORE CN:35 DOOR CN:12 EX. DEN 12'2'x16'4' LID I HDU14 W /1'6 T.R flk TC OW EMBED 12' 1 EX. DINING ROOM 11'0'x10'0' `k EX.'CRAWL SPACE' WITH 'HOUSE SUPPORTS' ALL TO REMAIN. MEL mutton MINIM X.CRAWL SPACE UP EX,_LIVING ROOM_ 13'4'x16'4' _-r -� 36 "MIN. HIGH RAILING WITH BALUSTERS SPACED SUCH THAT A SPHERE 4' IN DIAMETER CANNOT PASS THROUGH IT. EX7'0'x4'0"END SLIDER' — EX.FTG. LINE --- — — — -- — — --, EX. 7' 0'x4 0' END SLIDER -- — `% EX . PORCH MAIN FLOOR PLAN 1/4' =l'-0" EXISTING FOUNDATION Permit No. �rt rtwiew approval is stmt to errs and missions. t,: a! of constriction documents does not authorize t; is ^fion of any adopted code or ordinance. Receipt : of �ppaved Fi id Copy adraywledA ed: By Y 6 --/ 2- City Of Tukwila BUILDING DIVISION a ■ PLANNING APPROVED • No Changesf!lan be madeto these plans without approvid from the Plannirig Division of DCD Approved 13y:, 20' -8' S01UTH ELEVATION 1/4 ' = REAR ELEVATION NOTE • * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 2X6 STUDS a 16'0.C.- EXTERIOR WALLS 2X4 STUDS a 16'O.C.- INTERIOR WALLS AND GARAGE WALLS OR UNLESS OTHER WISE NOTED EXISTING 51' -0' -ni * * * * * *** * * * *_ * * * ** *ALL DIMENSIONS * *TO BE CHECkEL * *ON THE JOB SITE.* ************4=*-:: ** * P.T. MEANS PRESSURE TREATED EXISTING 30' -' ;' KEY: 5 = EXISTING WALLS 51:2:1-- REMOVE EXISTING WALLS .7=, NEW WALLS EX. MEANS EXISTING CN MEANS CODE NOTES D.H. MEANS DOUBLE HUNG F.G. MEANS FINISHED GRADE EC.RM FL EX. PL EX. 9' -10 3/4' EX.GARA6E FL EX.F.6_ REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of Tukwila BUILDING DIVISION EX.2'6'x2'6' SLIDER .EX,S'0'x4'0 SLIDER INCLUDIN ARCH EX.BATH Y.NEV B -F DOOR TO MATCH EX.; EX. BATH EX.BEDRQOM 11'2'- x12'8' SMOKE® DETECTOR CN:35 NEW ADDITION EX,BEDROOM 10'8'x13' NEV RECREATION ROOM 20'0'- x6' 0'+ VAULTED CEfLING EX.BEDROOM' 12'2'x12'8'+ MSTC48B3 MSTC48B3 EX.7'0'x3'10'END SLIDER EXISTING ROOF OVER EX. PORCH BELOW - ".— EX. x3'10'END SLIDER ECEIVED APR 16 2012 T CENTER 0 N SOLID NEV 5'0' (SEE ELI STUD CORNERS 3'0'ARCH OVER IATIONS) NEW1 4'0' SEPARATE PERMIT REQUIRED FOR: 4 NEW 5' -0' '0'x #` P WITH (24'END 5' -0'; 10' -0' NEW 1'0x4' SLIDERS) L� liPMechanical gioEiectrical E.ellumbing (was Piping t;:}j of Tukwila E t DIVISION NEW ADDITION 1'-0' EXISTING 30' -0' '" Dl CORRECTION LTR# .2ftwO8b EXISTING U 51' -0' PPER---- FL001t PLAN 1/4' = 1' -O" 360- 886 -1442 UT 19. t. bkAYH1LJ AND 1LLUJ I KA I IUHJ U'1tbl J AHD I Ht1K UJt 1J L.1111 l tll I U I Ht SINGLE SPECIFIED PROJECT. USE AND REPRODUCTION, WITHOUT THE CONSENT OF MEGI IS PROHIBITED BY COPYRIGHT LAWS. EVERY EFFORT HAS BEEN MADE TO AVOID INACCURACY IN THE PREPARATION OF THIS PLAN, OR DESIGN. HOWEVER MEGI CANNOT GUARANTEE AGAINST HUMAN ERROR. WRITTEN DIMENSIONS TAKE PRE- CEDENCE OVER. SCALE DIMENSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS-AND''DETAILS ON THE JOB SITE. THE LOCAL AUTHORITIES REQUIRE THAT. IT IS.. THE SOLE RESPONSIBILITY OF THE USER(S) OF THESE BUILDING PLANS TO ACCESS, READ, UNDERSTAND & FOLLOW EVERY BUILDING' CODE CURRENTLY ENFORCED THAT APPLIES TO THIS PROJECT. MLR UI 1 LI\ 1 _ 1 1l% J. I .v v... TOTAL LIVING AREA 2245.0 S.F. EXISTING GARAGE AREA 525.0 S.F. EX. FRONT PORCH 90.0 S.F. LD M il ,- 4 ,...; \ 0 0 I CATHY J. SPIKER & BRIAN FITTERER 206 -242 -8121 1 PEST AND SOUTH ELEVATIONS AND EX. FOUDATION1 AND MAIN FLOOR PLAN .AND UPPER FLOOR PLAN s M 1/4' = 1' -0' NEW ADDITION RIDGE SCREENED VENT(CN:82) NEW PITCH' TO MATCH 'EXISTING PITCH'. (12/12 ?) EX. ROOF RIDGE SCREENED VENT EX. 5/12 PITCH EX. PITCH 12 NEW REC. RM PL • EX UPPER PL EX. U "ER PL NEW DOWNSPOUT NEW RAILING NEW DECK EX PPER FL EX IN PL 00 REMODELED. DOWNSPOUT NOTE: REMOVE EXISTING GARAGE ROOF REC.RM FL -EX. DOWN- SPOUT DOWNSPOUTS EX. LOWER ROOF' UPPER REMODELED DOWNSPOUT NEW NEW PPOST 8' FOOTING EX MAIN FL NOTE: REMOVE EXISTING GARAGE ROOF" R i `__,. -- EXISTING 6 1/2' I EXI ING I' EXPOSURE WINO �.J EX. GARAGE PL -.41--EX. POSTS BEVEL SIDING- TYPICAL REMODELED DOWNSPOUT - NOTE: REMOVE EX. RAILING EX. RAILING MAIN PL MAIN FL GARAGE FL 1— .S1LPS .EAST ELEVATION 1/4' = 1' -0' ,,-- _- ____4X4 POST uSIMPSON PC44 D BEAM '(WCC). F4 NEW CORBEL : SEE ELEVATIONS: NEW P.T. 4x4x36'(BEAM) SUPPORT W/3- 1/2'6x8' LAG SCREWS INTO SOLID BLOCKING a EXIST: STUD WALL * * * * * * * * * * * * * * * * ** *ALL DIMENSIONS * *TO BE CHECKED * *ON THE JOB SITE.* EX. DEANS EXISTING CN MEANS CODE NOTES F.G. MEANS FINISHED GLADE' P.T. MEANS PRESSURE TREATED E.S. MEANS EACH SIDE A ATTIC VENTILATION: 1/150 MIN. OF ATTI. AREA = HALF(1 /300). AT 3'- O'MIN. ABOVE SAVE TO RIDGE (GABLE VENTS: RIDGE VENTS: ATTIC FANS: OR ETC.) +(PLUS) HALF(1 /300) AT SAVE OR CORNICE VENTS. VENT OPENINGS COVERED W /CORROSION- RESISTANT METAL 1/4' MESH. CN:82 lx FASCIA BOARD -TYP. OR TO MATCH EXISTING- NOTE • * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 2X6 STUDS a 16 "O.C.- EXTERIOR WALLS 2X4 STUDS a 16'0.C.- INTERIOR WALLS AND GARAGE WALLS OR UNLESS OTHER WISE NOTED Llt w S MPSON A48 a E.S. EX.(5)2x12 BEAM EX. (5)2x12 BEAM U410- SIMPSON 11U412 Li EX.UP /FL LINE/ I EX.PORCH POSTS t,eRtM JOIST CV / RIM JOIST' ...,„ _.,..._______ =`RIM JOIST 5' -6" 10'-0'.=; NEW ADDITION 21'- LINE OF REC. 5' -6' RM FLOOR UPPER FLOOR JOIST PLAN OVER MAIN FLOOR 1/4' = 1' -0' NTH o aZ agC I = rnOiS ELIC NEW DOWNSPOUT —5" CONTINUOUS G.L. METAL GUTTER -TYP. OR TO MATCH EXIST G NORTH ELEVATION. 1;4' =1' -0` FRONT ELEVATION EX. DOWNSPOUT -1fX.F.G. REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of Tukwila BUILDING DIVISION 4x10 (DF#2) 4 i 0 HD DF #2 GAS VENT CN:85.87 88.96 NEW 4x10 HDR(DF #2) PLACED OVER EX.UPPER PL AND SET NEXT TO 'EX. TRUSS. MPSON MSC4 (NJ C.0 CHIMNEY EX. DOWNSPOUTS O Z= Qo REMODELED' D(AINSPQUT Rq 24'0.C. -TYP DR DF #2) EX.LOWER.ROOF OV HANG 2x8 RAKE BOARD -TYP. 10' -6' OR TO MATCH EXISTING 4.OVERFING 21' -0' --NEW DOWNSPOUTS EXISTING 2 D�= �Bb NR TH ROOF PLAN C:62,77,82 1/41 = 11_Or RECEIVED APR 16 2012 PERMIT CENTER THESE IDEAS, DESIGNS, DRAWINGS, AND PLANS ARE OWNED AND /OR ARE PRODUCTS OF M.E.GRAPHICS AND ILLUSTRATIONS (MEGI)1 AND THEIR USE I.S LIMJTED TO THE SINGLE SPECIFIED PROJECT. USE AND REPRODUCTION, WITHOUT THE CONSENT OF MEGI IS PROHIBITED BY COPYRIGHT LAWS. EVERY EFFORT HAS BEEN MADE. TO AVOID INACCURACY IN THE PREPARATION OF THIS PLAN, OR DESIGN. HOWEVER MEGI CANNOT GUARANTEE AGAINST HUMAN ERROR. WRITTEN DIMENSIONS TAKE PRE - CEDENCE OVER SCALE DIMENSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE, FOR THE VERIFICATION OF ALL DIMENSIONS AND DETAILS ON THE JOB SITE. THE LOCAL AUTHORITIES REQUIRE THAT IT IS THE SOLE RESPONSIBILITY OF THE USER(S) OF THESE BUILDING PLANS TO ACCESS, READ. UNDERSTAND & FOLLOW EVERY BUILDING CODE CURRENTLY ENFORCED THAT APPLIES TO THIS PROJECT. ■ r ATTIC VENTILATION: 1/150 MIN. OF ATTIC AREA = HALF(1 /300) AT 3'40 "MIN. ABOVE SAVE TO RIDGE (GABLE VENTS: RIDGE VENTS: ATTIC FANS: OR ETC.) +(PLUS) HALF(1 /300) AT EAVE OR CORNICE VENTS. VENT OPENINGS COVERED W /CORROSION - RESISTANT METAL 1/4' MESH. CN:82 TYPICAL ROOFING: COMPOSITION TO MATCH EX. 1511 FELT 7 /16'MIN. APA RATED SHEATHING C -CX.a EXPOSED AREAS(EAVES) CN:77 *VENT BLOCKS BETWEEN ALL $AFTERS. (3)2 1/2 "6 SCREENED HOLES PER BLOCK - • METAL FLASHING. FASCIA BOARD - PER P *CHANNEL VENT. 1'MIN. •SIM :SON H2.5 ANCHOR -TYP. *PITCH (PER PLAN SEE ELEVATIONS) RAFTER FRAMING PER PLAN. R- 38ADVANCED INSULATION 5 /8'G.V..B.ON CEILING NEW 'REC.RM P /L- 5'CONTINUOUS G.J. METAL GUTTER -TYP. EW ADDITION 3' -0' OVERHANG PER PLAN TYPICAL SIDING: PER ELEVATIONS 1/2' PLYWOOD EXTERIOR SHEATHING 151 FELT OR 'TYVEK' HOUSEWRAP RIMINSU ATE a RIM e 2X6 BLOCKING 164 a 6'O.C. WALL BRACING PER R602.10 '24 GAUGE G.I. METAL SHIELD_ FINISHED GRADE (2)2X6 TOP PLATE HEADER PER PLAN °'':' IIINDOW FINISH * *INSULATED WINDOWS(U =.4) -ter-.+ SILL FINISH (2)2X6 SILL PLATE UNDER WINDOW NOTE : * * * * * * * ** - * * * * * * * * * * * * * * * * * * ** 2X6 STUDS a 16'0.C.- EXTERIOR WALLS 2X4 STUDS a 16"0.C.- IIpNNTT�EEp�RIOR WALLS OR UNLESS OTHERWISE NUM) WALLS 1 /2'G.W.B.GN WALLS R -21 INSULATION IN WALLS 2X6 SOLE PLATE °3/4'T.86. PLYWOOD SHEATHING NEW RECAP! FLOOR LIN Ih i11 a �l •1 WNSPOUT -DRA _1I TI GHT -LINE ----- " X GWB CN:14 FLOOR JOISTS PER. PLAN:- SOLID BLOCKING OVER SUPPORT WALL AND a MID SPAN a 8'- O'MAX: R -30 INSULATION W/VAPOR BARRIER 2)2X6 TOP PLATE EXISTING UNHEATED , GARAGE 2X6 SOLE PLATE 2X6 - PRESSURE TREATED MUDSILL..OR„ CEDAR EX. ANCHOR BOLTS 04' CONCRETE SLAB W /6'x6' 10 /10 WELDED WIRE MESH OVER 6 MIL. VISQUEEN OVER 4' GRAVEL EX. GARAGE EX.6ARAGE4 P/L F/L 4 t 4 •FILTER CLOTH BETWEEN DIRT & WASHED GRAVEL ABOUT 4' 0 PERFORATED DRAIN TILE EX.FOUNDATION MALL EX. FOOTING *** * * *** * * * * *** * ** *ALL DIMENSIONS * *TO BE CHECKED *ON THE JOB SITE.* TYPICAL WALL EX. MEANS EXISTING CN MEANS CODE NOTES *NOTE: SEE ALSO* *THE ENGINEERING.* *THE SPECIFIC . *ENGINEERING NOTES* *AND DETAILS SHALL* *TAKE PRECEDENCE* *OVER THE STANDARD* *NOTES & DETAILS. SECTION 3/4' =l' -0' FOUNDATION AND CONCRETE NOTE: CONCRETE FC = 3000 PSI AFTER 28 DAYS HORIZONTAL REBAR 8x12(.0020)= .192 SQ.INCHZFT VERTICAL REBAR 8x12(.0012)= .1152 SQ.INCH /FT SCHEDULE 40 STEEL NOTE: UNDISTURBED EARTH UNDER FOOTING AND FOUNDATION WALL W /MIN. BEARING OF 1500 PSF. 21' -0' 2' -O. fIAIN ROOF 5/12 OVERHANG PITCH TO MATCH EX., GARAGE: DOOR \' OPENING GARAGE DOOR OPENING NORTH DORMER FRAMING DETAIL 114' = 1' -0 "' 3 1 (SOUTH DORMER FRAMING SIMILAR) E 36'MIN. HIGH RAILING WITH BALUSTERS SPACED SUCH THAT A SPHERE 4' IN DIAMETER CANNOT PASS THROUGH IT. NEW DECKING TRE�iEaISTSHE. 0 1' -O" 2' -Ow 27'-0' 13' -6' 13' -6' DORMER ROOF PITCH TO MATCH EX. 12/12 NEW DORMER -RIDGE BEAM 2' -0' 2' -0 OVER NG R -21 INSULATION IN WALLS-NEW SOLID BLOCKING- NEW NEW SOLID BLOCKING StBFLOORING -,NEB' FLOOR - JOISTS -NEW NEW 4x10 BEAM(DF#2). EX. F.G. - 1'-16' ,NEW POST NEW FOOTING, NEW 1' -0' CANTILEVE 3' -6' NEW R -30 INSULATION IN FLOOR NEW REC. NEW REC. -RM FL RIM JOIST EX. GARAGE PL E X GW.B CN EX. GARAGE STUD WALLS TO REMAIN: EX. CONCRETE FLOOR TO REMAIN EXISTING FOUNDATION WALL & FOOTING' TO REMAIN NOTE • * * * * * * * * * * * * * * * * * * * * * * ** - * * * ** 2X6 STUDS a 16 "O.C.- EXTERIOR WALLS 2X4 STUDS a 16'O.C.- INTERIOR WALLS OR UNLESS OTHERWIEGNOTED WALLS F.G. MEANS FINISHED GRADE HOUSE ROOF EX.UPPE L • 91 I • w OPENING ' HEADER NEW STEP (7/"MAX.: EX UPPERF 6 3/4' 311111111111 11111110_ CHANNEL VENT NEW 'REC. -RM 1' —°OPEN EX. STUD WALL UP'TO EX. PLATE LINE EX.MAIN PL • 1 0- Lr NEW REC. LOOK JOISTS EX. GARAGE EX.CONCRETE FLOOR EX.MAIN FL, • EX. CRAWL SPACE EXFDTN'"WALL 8 FTG. HEIGHT DETAIL 1/4" =1' -0' 3' -0' OVERHANG CROSS SECTION 1/4 " =l' -0 27' -0' 13' -6' 13' -6' NEW EXTERIOR PLYWOOD SHEATHING UNDER CANTILEVERED FLOOR JOISTS X73" CONTINUOUS SCREENED AIR VENT - TYPICAL. • M • W EX. GARAGE FL 3' -0 OVERHANG 44.0 DFI2 MAIN ROOF RIDGE -BEAM 12 L/" MAIN ROOF RAFTERS R- 38ADVA� LNSU DBL FULL NEW STUD HEIGHT Ate.: ~� a= SOLE PLATE SUBFLOORING CO DBL STUD FULL HEIGHT 311/8'x9 "GLB(24F -v4): • C.0 M M �a an � EX.GARAGE IX.WALL PLATE LINE EX. STUD WALL--k. NEW 4x4 POST NEW. 4X6 POST �— 4X4 • POST - NEW EX. SOLE PLATE EX. MUDSILL EX. F.G. * * * * * * * * * * * * * * *i ** *ALL DIMENSIONS * TO BE CHECKED *' *ON THE JOB SITE. ' EX. F.G. 1 ,-I 4-- Ammo mAr■ EX . ■CaICRETE FLOOR f � � - � � � � � H EX.FOUNDATION WALL & FOOTINGS FX. 'EAST WALL FRAMING' 1/4' = 1' -0' p ra� OBt REVIEWED FOR CODE COMPLIANCE APPROVED APR182012 City of Tukwila BUILDING DIVISION RECEIVED APR 16 2012 PERMIT CENTER M.E.VELTHAUSER** *DESIGNER * * *1 - 800 -560 -1442 360 -886 -1442 THESE IDEAS, DESIGNS, DRAWINGS, AND PLANS ARE OWNED AND /OR ARE PRODUCTS OF M.E.GRAPHICS AND ILLUSTRATIONS (MEGI), AND THEIR USE IS LIMITED TO THE SINGLE SPECIFIED PROJECT. USE AND REPRODUCTION, WITHOUT THE CONSENT OF MEGI IS PROHIBITED BY COPYRIGHT LAWS. EVERY EFFORT HAS BEEN MADE TO AVOID.INACCURACY IN THE PREPARATION OF THIS PLAN, OR DESIGN. HOWEVER MEGI CANNOT GUARANTEE AGAINST HUMAN ERROR. WRITTEN DIMENSIONS TAKE PRE- CEDENCE OVER SCALE DIMENSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND DETAILS ON THE JOB SITE. THE LOCAL AUTHORITIES REQUIRE THAT IT IS THE SOLE RESPONSIBILITY OF THE USER(S) OF THESE BUILDING PLANS TO ACCESS, READ, UNDERSTAND & FOLLOW EVERY BUILDING CODE CURRENTLY ENFORCED THAT APPLIES TO THIS PROJECT. W N o3. SPIKER 8 BRIAN FITTERER 206- 242 -8121 H 168TH STREET, TUKWILA, WA 98188 SECTIONS AND DETAILS • WI 1C I' IL II 0 CODE KIM. TO WHOM IT MAY CONCERN: PLEASE APPLY ONLY THOSE NOTES THAT CORRESPOND TO THIS PROJECT. ALL OTHER NOTES ARE NOT APPLICABLE. THANK YOU MEGI AS PROVIDED BY THE ICC ALL CODES MUST BE ADHERED TO AS ARE APPLICABLE TO THIS. SPECIFIC PROJECT,. THUSLY: IRC 2009 VITH IBC, IEBC, IECC, IEC IBC. IPMC, IZC, IPC, IPSDC AND THE IFGC. CURRENT, WASHINGTON STATE ENERGY CODE. THE FOLLOWING CODE NOTES EXCEPTS F20009 pi RNAT ONA . E TIONAL .RESIDENTIAL CODE 1 HABITABLE SPACE. A SPACE IN A BUILDING FOR LIVING SLEEPING, EATING OR COOKING. BATHROOMS, TOILET ROOMS, CLOSETS, HALLS, STORAGE OR UTILITY SPACES AND SIMILAR AREA ARE NOT CONSIDERED HABITABLE SPACES. 2 R303.1 HABITABLE ROOMS. ALL HABITABLE LE ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA OF NOT LESS THAN 8 PERCENT OF THE FLOOR AREA OF SUCH ROOMS. NATURAL VENTILATION SHALL BE THROUGH WINDOWS; DOORS, LOUVERS OR OTHER APPROVED OPENINGS TO THE OUTDOOR AIR. SUCH OPENINGS SHALL BE. PROVIDED WITH READY ACCESS OR SHALL OTHERWISE BE READILY CONTROLLABLE BY THE BUILDING OCCUPANTS. THE MINIMUM OPENABLE AREA TO THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING VENTILATED. SEE EXCEPTIONS TO R303.1 3 R303.2 ADJOINING ROOMS. FOR THE PURPOSE OF DETERMINING LIGHT AND VENTILATION REQUIREMENTS, ANY ROOM SHALL BE CONSIDERED AS A PORTION OF AN ADJOINING ROOM WHEN AT LEAST ONE -HALF OF THE AREA OF THE COMMON WALL IS OPEN AND UNOBSTRUCTED AND PROVIDES AN OPENING OF NOT LESS THAN ONE -TENTH OF THE FLOOR AREA OF THE INTERIOR ROOM BUT NOT LESS THAN 25 SQUARE FEET(2.32M2). 4 R303.3 BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SQUARE FEET (0.279M2), ONE -HALF OF WHICH MUST BE OPENABLE. EXCEPTION: THE GLAZING AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION. SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50CFM (24.lL /S) FOR INTERMITTENT VENTILATION OR 20 CFM (10 L /s) FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE . EXHAUSTED DIRECTLY TO THE OUTSIDE. 5 R303.7 REQUIRED GLAZED OPENING SHALL OPEN DIRECTLY ONTO A STREET OR PUBLIC ALLEY, OR A. YARD OR COURT LOCATED ON THE SAME LOT AS THE BUILDING. R303.7.1 REQUIRED GLAZED OPENINGS MAY FACE INTO A ROOFED PORCH WHERE THE PORCH ABUTS A STREET, YARD OR COURT AND THE LONGER SIDE OF THE PORCH IS A LEAST 65 PERCENT OPEN AND UNOBSTRUCTED AND THE CEILING HEIGHT IS NOT LESS THAN 7 FEET (2134MM). 6 R303.8 REQUIRED HEATING. WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(1) IS BELOW 60 °F (16 °C), EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68 °F (20 °C) AT A POINT 3 FEET (914MM) ABOVE THE FLOOR AND 2 FEET (610MM) FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS SECTION. 7 CEILING HEIGHT: R304.4 HEIGHT EFFECT ON ROOM AREA. PORTIONS OF A ROOM WITH A SLOPING CEILING MEASURING LESS THAN 5 FEET (1524MM) OR A FURRED CEILING MEASURING LESS THAN 7 FEET(2134MM) FROM THE FINISHED FLOOR TO THE FINISHED CEILING SHALL NOT BE CONSIDERED AS CONTRIBUTING TO THE MINIMUM REQUIRE HABITABLE AREA FOR THAT ROOM. R305.1 MINIMUM HEIGHT. HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS AND BASEMENTS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134MM). THE REQUIRED HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE LOWEST PROJECTION FROM THE CEILING. EXCEPTIONS: BEAMS AND GIRDERS SPACED NOT LESS THAN 4 FEET (1219MM) ON CENTER MAY PROJECT NOT MORE THAN 6 INCHES (152MM) BELOW THE REQUIRED CEILING HEIGHT. R305.1.1 CEILINGS IN BASEMENTS WITHOUT HABITABLE SPACES MAY PROJECT TO WITHIN 6 FEET, 8 INCHES (2032MM) OF THE FINISHED • FLOOR; AND BEAMS, GIRDERS, DUCTS OR OTHER OBSTRUCTIONS MAY PROJECT TO WITHIN 6 FEET, 4 INCHES (1931MM) OF THE FINISHED FLOOR 1, NOT MORE THAN 50 PERCENT OF THE REQUIRED FLOOR AREA OF A ROOM OR SPACE IS PERMITTED TO HAVE A SLOPED CEILING LESS THAN 7 FEET (2134MM) IN HEIGHT WITH NO PORTION OF THE REQUIRED FLOOR AREA LESS THAN 5 FEET (1524MM) IN HEIGHT. 8; 2. BATHROOMS SHALL HAVE A MINIMUM CEILING HEIGHT OF 6 FEET 8 INCHES (2036MM) OVER THE FIXTURE AND AT THE FRONT CLEARANCE AREA FOR FIXTURES AS SHOWN IN FIGURE R307.1. A SHOWER OR TUB EQUIPPED WITH A SHOWERHEAD SHALL HAVE MINIMUM CEILING HEIGHT OF 6 FEET 8 INCHES (2036MM) ABOVE A MINIMUM AREA 30 INCHES (762MM) BY 30 INCHES AT THE SHOWERHEAD. TOILET, BATH AND SHOWER SPACES 9 R307.1 SPACE REQUIRED OF FIXTURES SHALL BE SPACED AS PER FIGURE R307.1 TOILET AREA TO BE MINIMUM 30 INCHES WIDE AND 21 INCHES CLEARANCE IN FRONT 10 R307.2 BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO HEIGHT OF NOT LESS THAN 6 FEET (1829MM) ABOVE THE FLOOR. 11 R308.6.1 SKYLIGHTS AND SLOPED GLAZING. GLASS OR OTHER TRANSPARENT OR TRANSLUCENT GLAZING MATERIAL INSTALLED AT A SLOPE OF MORE THAN 15 DEGREES (0.26 RAD) FROM VERTICAL. GLAZING MATERIALS IN SKYLIGHTS, INCLUDING UNIT SKYLIGHTS, SOLARIUMS, SUNROOMS, ROOFS AND SLOPED WALLS ARE INCLUDED IN THIS DEFINITION. UNIT SKYLIGHT. A FACTORY ASSEMBLED, GLAZED FENESTRATION UNIT, CONTAINING ONE PANEL OF GLAZING MATERIAL, THAT ALLOWS FOR NATURAL DAYLIGHTING THROUGH AN OPENING IN THE ROOF ASSEMBLY WHILE PRESERVING THE WEATHER RESISTANT BARRIER OF THE ROOF. PERMITTED MATERIALS AS PER R308.6.2. R308.6.8 ALL UNIT SKYLIGHTS INSTALLED IN A ROOF WITH A PITCH FLATTER THAN 3 UNITS VERTICAL IN 12 UNITS HORIZONTAL(25% SLOPE) SHALL BE MOUNTED ON A CURB EXTENDING AT LEAST 4 INCHED(102MM) ABOVE THE PLANE OF THE ROOF UNLESS OTHERWISE SPECIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTION. ALL TESTING AND LABELING AS PER R308.6.9. GARAGES AND CARPORTS: 12 OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES (35MM) IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8 INCHES THICK, OR 20- MINUTE FIRE -RATED DOORS. 14 THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH(12.7MM) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8 -INCH (15.9MM) TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR- CEILING ASSEMBLE, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2 -INCH T 15 R309.1 GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. 16 R309.2 CARPORTS SHALL BE OPEN ON AT LEAST TWO SIDES. CARPORT FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL. CARPORT NOT OPEN ON A LEAST TWO SIDES SHALL BE CONSIDERED A GARAGE AND SHALL COMPLY WITH THE PROVISIONS OF THIS SECTION FOR GARAGES. 17 THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES .z� SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. 18 R309.4 AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL325. EMERGENCY ESCAPE AND RESCUE OPENINGS: 19 R310.1 BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENING SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES (1118MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL COMPLY WITH SECTION 310.3 THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2. ALL OPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5.7 SQUARE FEET (0.465MM) WITH THE EXCEPTION OF GRADE FLOOR OPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 S.F. R310.1.1 MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 INCHED (610MM). R310.1.2 MIN. NU CLEA OPENING WIDTH SHALL BE 20 INCHES (SO8MM) R310.1.3. THE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. R310.1.4 20 R310.2 WINDOW WELLS. THE MIN. HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9 SQ.FT. (0.84m L), WITH A MIN. HORIZONTAL PROJECTION AND WIDTH OF 36 INCHES (914MM). THE AREA OF THE WINDOW WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED. FOR EXCEPTIONS SEE R310.2.1. 21 HALLWAYS: THE MIN. WIDTH OF A HALLWAY SHALL BE NOT LESS THAN 3 FEET (914MM). R311.6. 25� STAIRWAYS: STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES (914MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES (114MM) ON EITHER SIDE OF THE STAIRWAY AND THE MIN. CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE LESS THAN 31.5 INCHES (787MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. R311.7.1 26 27 28 THE MIN. HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6 FEET 8 INCHES (2036MM) MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM. R311.7.2 THE MAX. RISER HEIGHT SHALL BE 7- 3/4' INCHES (196MM). THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5MM). R311.7.4.1 THE MIN. TREAD DEPTH SHALL BE 10 INCHES (254MM). THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3 /8INCHES (9.5MM). WINDER TREADS SHALL HAVE A MIN. TREAD 10 INCHES MEASURED AT A POINT 12 INCHES (305MM) FROM THE SIDE WHERE THE TREADS ARE NARROWER; AND SHALL HAVE A MIN. TREAD DEPTH OF 6 INCHES(152MM) AT ANY POINT R311.7.4..2. THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE GO GREATER THAN 9/16 INCH(14. MM). A NOSING NOT LESS THAN 3/4 INCH(19MM) BUT NOT MORE THAN 1 1/4 INCH (32MM) SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS. R311.7.4.3. 29 THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. EXCEPTION: A FLOOR OR LANDING IS NOT REQUIRED AT THE TOP OF AN INTERIOR FLIGHT OF STAIRS, PROVIDED A DOOR DOES NOT SWING OVER THE STAIRS. A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISE GREATER THAN 12 FEET (3658MM) BETWEEN FLOOR LEVELS OR LANDINGS. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE STAIRWAY SERVED WITH A MIN. DEPTH OF 36 INCHES (914MM). R311.7.5. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS. R311.-1.7. HANDRAIL HEIGHT SHALL BE NOT LESS THAN 34 INCHES (864MM)AND NOT MORE THAN 38 INCHES(965MM). R311.7.'1.1 HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1 1/2 INCH (38MM) BETWEEN THE WALL AND THE HANDRAILS. R311.7.7.2. 1 SEE R311.7.7.3 FOR HANDRAIL GRIP SIZE. 2 ALL STAIRS SHALL BE PROVIDED WITH ILLUMINATION IN ACCORDANCE WITH SECTION R303.6 ;R311.8.7. 3 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 INCH (12.7MM) GYPSUM BOARD. 30 22 DOORS: ONE EXIT DOOR CONFORMING TO THIS SECTION (R311.1) SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. SEE ALSO R311.2 THE EXIT DOOR SHALL BE A SIDE - HINGED DOOR NOT LESS THAN 3 FEET (914MM) IN WIDTH AND 6 FEET 8 INCHES`(2032MM) IN HEIGHT. 2.3 EVERY EXIT DOOR LANDING SHALL HAVE A MIN. DIMENSION OF 36 INCHES (914MM) MEASURED IN THE DIRECTION OF TRAVEL, AND THE WIDTH THE DOOR MIN. AS PER R311.3 ALSO THE FLOOR LANDING SHALL NOT BE MORE THAN 1.5 INCHES (38MM) LOWER THAN THE TO OF THE THRESHOLD. EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 7 3/4 INCHES (196MM) BELOW THE TOP OF THE(R311.3.2) THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. ALSO EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR. THE EXTERIOR SIDE OF THE DOOR. 3 3 3 34 PORCHES, BALCONIES OR RAISED FLOOR SURFACES LOCATED MORE THAN 30 INCHES(762MM) ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36 INCHES(914MM) IN HEIGHT. OPEN SIDES OF STAIRS WITH A TOTAL RISE OF MORE THAN 30 INCHES(762MM) ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 34 INCHES(864MM) IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. R312.1. THE INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL NOT ALLOW PASSAGE OF A SPHERE 4 INCHES (102MM) OR MORE IN DIAMETER. R312.3 24 ALL EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. R311.2 FACE OF STRUCTURE TOE OF SLOPE For SI: 1 foot = 304.8 mm. /FACE OF v FOOTING TOP OF SLOPE H/2 BUT NOT EXCEED 15 FT. MAX. H/3 BUT NEED NOT EXCEED 40 FT. MAX. FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES 35 IRC 315.1: CARBON MONOXIDE ALARMS. FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHAI1 BEINSTALLED OUTSIDE OF_ -EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS. SMOKE ALARMS R314.3 SMOKE ALARMS SHALL BE INSTALLED IN: EACH SLEEPING ROOM; OUTSIDE EACH SEPARATE SLEEPING AREA; ON EACH ADDITION STORY OF THE DWELLING; EXCEPT CRAWL SPACES UNINHABITABLE ATTICS, ALL SMOKE ALARMS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISION OF NFPA 72. ALSO R314.4. IN NEW CONSTRUCTION, THE REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED 50 FROM A COMMERCIAL SOURCE, AND WHEN PRIMARY POWER IS INTERRUPTED, SHALL RECEIVE POWER FORM A BATTERY. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE PERMITTED TO BE BATTERY OPERATED WHEN INSTALLED IN BUILDINGS WITHOUT COMMERCIAL POWER OR IN BUILDINGS THAT UNDERGO ALTERATIONS, REPAIRS OR ADDITIONS 47 A 6- MIL - THICK (0.15MM) POLYETHYLENE FILM SHALL BE APPLIED OVER THE BELOW -GRADE PORTION OF EXTERIOR FOUNDATION WALLS PRIOR TO BACKFILLING. JOINTS SHALL BE LAPPED 6' (152MM) AND SEALED WITH ADHESIVE. THE TOP EDGE OF THE POLYETHYLENE FILM SHALL BE BONDED TO THE SHEATHING TO FORM A SEAL. R406.3.2. 48 49 36. MOISTURE VAPOR RETARDERS AS PER SECTION R601. 37 PROTECTION AGAINST DECAY AS PER SECTION R317. POST, POLES AND COLUMNS SUPPORTING PERMANENT STRUCTURES THAT ARE EMBEDDED IN CONCRETE IN DIRECT CONTACT WITH THE GROUND OR EMBEDDED IN CONCRETE EXPOSED TO THE WEATHER SHALL BE APPROVED PRESSURE PRESERVATIVFLY TREATED WOOD SUITABLE FOR GROUND CONTACT USE. 18317.2 51 CRAWL SPACE PER SECTION R408. THE MIN. NET AREA OF VENTILATION OPENINGS SHALL NOT BE LESS THAN 1 SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDER -FLOOR SPACE AREA. ONE SUCH VENTILATING OPENING SHALL BE WITH 3 FEET(914MM) OF EACH CORNER OF THE BUILDING. CRAWL SPACE ACCESS OPENINGS THROUGH THE FLOOR SHALL BE A MIN. OF 18' BY 24" (457MM BY 610MM). OPENINGS THROUGH A PERIMETER WALL SHALL BE 16" BY 24' (407MM BY 610MM). THROUGH WALL ACCESS OPENINGS SHALL NOT BE LOCATED UNDER A DOOR TO THE RESIDENCE. SEE SECTION M1305.1.4. FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED UNDER FLOORS. R408.4. THE FINISHED GRADE OF UNDER -FLOOR SURFACE MAY BE LOCATED AT THE BOTTOM OF THE FOOTINGS: HOWEVER, WHERE THERE IS EVIDENCE THAT THE GROUNDWATER TABLE CAN RISE TO WITHIN 6' OF THE FINISHED FLOOR AT THE BUILDING PERIMETER OR WHERE THERE IS EVIDENCE THAT THE SURFACE WATER DOES NOT READILY DRAIN FROM THE BUILDING SITE, THE GRADE IN THE UNDER -FLOOR SPACE SHALL BE AS HIGH AS THE OUTSIDE FINISHED GRADE, UNLESS AN APPROVED DRAINAGE SYSTEM IS PROVIDED. R408.6. 52 WOOD FLOOR FRAMING AS PER CHAPTER 5. 53 ,SPANS FOR FLOOR JOISTS SHALL BE IN ACCORDANCE WITH TABLES R502.3.1(1) AND R502.3.1(2). FOR OTHER GRADES AND SPECIES AND FOR OTHER LOADING CONDITIONS, REFER TO THE AF &PA SPAN TABLES FOR JOISTS AND RAFTERS. FOUNDATION DRAINAGE AS PER SECTION R405. 55 R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING. EXCEPT WHERE REQUIRED TO BE WATERPROOFED BY SECTION R406.2, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACES LOCATED BELOW GRADE SHALL BE DAMPPROOFED FROM THE TOP OF THE FOOTING TO THE ..FINISHED GRADE.. MASONRY WALLS SHALL__ HAVE NOT LESS THAN 3/8 "(9.5MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL THE PARGING SHALL BE DAMPPROOFED WITH A BITUMINOUS COATING, OR 3 POUNDS PER SQUARE YARD(1.63 KG /M2)_OF ACRYLIC MODIFIED CEMENT, OR 1/8 "(3.2MM) COAT OF SURFACE - BONDING MORTAR.COMPLYING WITH ASTM C 887 OR ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2. CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE ABOVE LISTED DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF THE WALL. 38 PROTECTION AGAINST TERMITES A PER 54 SECTION R318. 39 FLOOD RESISTANT CONSTRUCTION AS PER SECTION R322. 40 41 FOUNDATIONS AS PER CHAPTER 4. FOUNDATION CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS TO THE SUPPORTING SOIL. FILL SOILS THAT SUPPORT FOOTINGS AND FOUNDATIONS SHALL BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE= SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE ci OTHER APPROVED POINT OF COLLECTION SO AS TO NOT CREATE A HAZARD. LOTS "SHALL BE GRADED SO AS TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. (SHALL FALL A MIN. OF 6 INCHES(152Mn) WITHIN THE FIRST 10 FEET(3048MM). R401.3. EXCEPTIONS: WHERE LOT LINES, WALLS, SLOPES OR OTHER. PHYSICAL BARRIERS PROHIBIT 6 INCHES (152MM) OF FALL WITHIN 10 FEET (3048MM), DRAINS OR SWALES SHALL BE PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. 42 FOOTINGS: ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUS SOLID OR FULLY GROUTED MASONRY OR CONCRETE FOOTINGS, WOOD FOUNDATIONS, OR OTHER APPROVED STRUCTURAL SYSTEMS .• WHICH SHALL BE OF SUFFICIENT DESIGN TO ACCOMMODATE ALL LOADS ACCORDING TO SECTION R301 AND TO T1RANSMIT THE RESULTING I`:OADS TOil L SOIL WITHIN ' THE LIMITATIONS AS /DETERMINED FROM THE CHARACTER OF THE SOIL. FOOTINGS SHALL BE SUPPORTED ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL (SECTION R403). FOUNDATIONS. 43 ALL EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES (305MM) BELOW THE UNDISTURBED GROUND SURFACE. WHERE APPLICABLE, THE DEPTH OF FOOTINGS SHALL ALSO CONFORM TO SECTIONS R403.1.4.1. THROUGH R403.1.4.2. FROST PROTECTION AS PER R403.1.4.1. 44 SLOPE: THE TOP SURFACE OF FOOTINGS SHALL BE LEVEL. THE BOTTOM SURFACE OF FOOTINGS SHALL NOT HAVE A SLOPE EXCEEDING ON UNIT VERTICAL IN 10 UNITS HORIZONTAL (10- PERCENT SLOPE). FOOTINGS SHALL BE STEPPED WHERE IT IS NECESSARYTO CHANGE THE ELEVATION OF THE TOP SURFACE OF THE FOOTINGS OR WHERE THE SLOPE OF THE BOTTOM SURFACE OF THE FOOTINGS WILL EXCEED ONE UNIT VERTICAL IN TEN UNITS HORIZONTAL (10- PERCENT SLOPE). R403.1.5. 45 FOUNDATION ANCHORAGE AS PER R403.1.6. 46 THE PLACEMENT OF BUILDING AND STRUCTURE ON OR ADJACENT TO SLOPES STEEPER THAN 1 UNIT VERTICAL IN 3 UNITS HORIZONTAL (33.3Z SLOPE) SHALL CONFORM TO • SECTIONS R403.1.7.1 THROUGH R403.1.7.4. 56 57 58 59 60 61 FLOOR JOISTS: BEARING: THE ENDS OF EACH JOIST, BEAM OR GIRDER SHALL HAVE NOT LESS THAN 1.5'(38MM) OF BEARING ON WOOD OR METAL AND NOT LESS THAN 3 "(76MM) ON MASONRY OR CONCRETE EXCEPT WHERE SUPPORTED ON A 1' BY 4' (25.4MM BY FLOORS 102MM) RIBBON STRIP AND NAILED TO THE ADJACENT STUD OR BY THE USE OF APPROVED JOIST HANGERS. R502.6. FLOOR SYSTEMS: JOISTS FRAMING FROM OPPOSITE SIDES OVER A BEARING SUPPORT SHALL LAP A MIN. OF 3` AND SHALL BE NAILED TOGETHER WITH A MIN. OF 3- 10D FACE NAILS. A WOOD OR METAL SPLICE WITH STRENGTH EQUAL TO OR GREATER THAN THAT PROVIDED BY THE NAILED LAP IS PERMITTED. R502.6.1. * * * * * * * * * * * * * * * * * ** *NOTE SEE ALSO* *THE ENGINEERING.* *THE SPECIFIC *ENGINEERING NOTES* *AND DETAILS SHALL* *TAKE PRECEDENCE* *OVER THE STANDARD* *NOTES & DETAILS. * * * * * * * * * * * * * * * * * ** 62 WOOD TRUSSES:R502.11; SHALL BE DESIGNED IN ACCORDANCE WITH APPROVED ENGINEERING PRACTICE.. THE DESIGN AND MANUFACTURE OF METAL PLATE CONNECTED WOOD TRUSSES SHALL COMPLY WITH ANSI /TPI 1. THE TRUSS DESIGN DRAWINGS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL WHERE REQUIRED BY THE STATUTES OF THE JURISDICTION IN WHICH THE PROJECT IS TO BE CONSTRUCTED IN ACCORDANCE WITH SECTION R106.1. TRUSSES SHALL BE BRACED PER R502.11.2. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, SPLICED OR OTHERWISE ALTERED IN ANY WAY WITHOUT THE APPROVAL OF A REGISTERED DESIGN PROFESSIONAL. R502.11.3 64 WALL CONSTRUCTION PER CHAPTER_6. 65 _FLOOR FRAMING SHALL BE NAILED IN ACCORDANCE WITH TABLE R602.3(1') (INCLUDED). 66 CONCRETE FLOORS (ON GROUND) AS PER SECTION R506. CONCRETE SLAB -ON- GROUND FLOORS SHALL BE A MIN. 3.5 "(89MM) THICK (FOR EXPANSIVE' SOILS, SEE SECTION R403.1.8.) THE SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SHALL BE AS SET FORTH IN SECTION R402.2. 67 BASE: A 4" THICK (102MM) BASE COURSE CONSISTING OF CLEAN GRADED SAND, GRAVEL, CRUSHED STONE OR CRUSHED BLAST- FURNACE SLAG PASSING A 2" SIEVE SHALL BE PLACED ON THE PREPARED SUBGRADE WHEN THE SLAB IS BELOW GRADE. EXCEPTION: A BASE COURSE IS NOT REQUIRED WHEN THE CONCRETE SLAB IS INSTALLED ON WELL - DRAINED OR SAND - GRAVEL - MIXTURE SOILS CLASSIFIED AS GROUP I ACCORDING TO THE UNITED SOIL CLASSIFICATION SYSTEM IN ACCORDANCE WITH TABLE R405:1. 68 A 6 MIL.POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6' SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. R506.2.3. 63 FLOOR SHEATHING PER CHAPTER 5 JOIST FRAMING: JOISTS FRAMING INTO THE SIDE OF A WOOD GIRDER SHALL BE SUPPORTED BY APPROVED FRAMING ANCHORS OR ON LEDGER STRIPS NOT LESS THAN NOMINAL 2' BY 2' (51MM BY 51MM). R502.6.2. LATERAL RESTRAINT AT SUPPORTS: JOISTS SHALL BE SUPPORTED LATERALLY AT THE ENDS BY FULL -DEPTH SOLID BLOCKING NOT LESS THAN 2' NOMINAL IN THICKNESS: OR BY ATTACHMENT TO A HEADER, BAND, OR RIM JOIST, OR TO AN ADJOINING STUD: OR SHALL BE OTHERWISE PROVIDED WITH LATERAL SUPPORT TO PREVENT ROTATION. R502.7. BRIDGING: JOISTS EXCEEDING A NOMINAL 2" BY 12" (51MM BY 305MM) SHALL BE SUPPORTED LATERALLY BY SOLID BLOCKING, DIAGONAL BRIDGING (WOOD OR METAL), OR A CONTINUOUS 1' BY 3 "(25.4MM BY 76MM) STRIP NAILED ACROSS THE BOTTOM OF JOISTS PERPENDICULAR TO JOISTS AT INTERVALS NOT EXCEEDING 8 FEET(2438MM). R502.7.1. DRILLING AND NOTCHING:: STRUCTURAL FLOOR MEMBERS SHALL NOT BE CUT, BORED OR NOTCHED IN EXCESS OF THE LIMITATIONS SPECIFIED IN THIS SECTION. SEE FIGURE R502.8.(INCLUDED). • L/3„ 1D/3 MAX. NO NOTCHES Ill PERMITTED L L/3 1D/6 MAX. FLOOR JOIST - CENTER CUTS D/4 MAX. MAX. D FROM SUPPORT 1 1 D/3 MAX. D/3 MAX. FLOOR JOIST -END CUTS 4/3 MAX. 0/8 MAX. D/4 MAX. RAFTER/CEILING JOISTS 2 N. MIN. FROM TOP AND BOTTOM OF JOIST PIPE OR CONDUIT 0 (ACTUAL DEPTH) For SI: I inch = 25.4 mm. FIGURE R502.8 CUTTING, NOTCHING AND DRILLING 1 REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of Tukwila BUILDING DIVISION TABLE R602.3(1) FASTENER SCHEDULE FOR STRUC ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER'• ^' • SPACING OF FASTENERS Roof • 1 Blocking between joists or rafters to top plate, toe nail 3 -8d (21/2" x 0.113 ") - 2 Ceiling joists to plate, toe nail 3 -8d (2'/2" x 0.113 ") 3 -10d - - 3 Ceiling joists not attached to parallel rafter, laps over partitions, face nail 4 Collar tie rafter, face nail or 11/4" x 20 gage ridge strap 3 -10d (3" x 0.128 ") - $ Rafter to plate, toe nail 2 -16d (3'/2' x 0.135 ") 4 -16d (342" x 0.135 ") 3 -16d (3'/2" x 0.135 ") - - - 6 Roof rafters to ridge, valley or hip rafters: toe nail face nail Wall 7 Built -up corner studs Built -up header, two pieces with 1/2" spacer Continued header, two pieces 10d (3" x 0.128 ") 16d (31/2" x 0.135 ") 16d (31 /2" X 0.135 ") 24" o.c. • 16" o.c. along each dg 16" o.c. along each edge 8 9 10 Continuous header to stud, toe nail 4 -8d (2' /2" x 0.113 ") - 11 Double studs, face nail 10d (3" x 0.128 ") 24" o.c. 12 Double top plates, face nail 10d (3" x 0.128 ") 24" o.c. 13 Double top plates, minimum 48 -inch offset of end joints, face nail in lapped area 8 -16d (31/2" x 0.135 ") - 14 Sole plate to joist or blocking, face nail 16d (3'/2" x 0.135 ") 16" o.c. 15 Sole plate to joist or blocking at braced wall panels 3 -16d (31/2" x 0.135 ") 16" o.c. 16 Stud to sole plate, toe nail 3 -8d (2'/2" x 0.113 ") or 2 -16d 31/2" x 0.135 ") - - 17 Top or sole plate to stud, end nail 2 -16d (31 /2" X 0.135 ") - 18 Top plates, laps at corners and intersections, face nail 2 -10d (3" x 0.128 ") - 19 1" brace to each stud and plate, face nail 2-8d (2'/2" x 0.113 ") 2 staples 13/4" - -- 20 1" x 6" sheathing to each bearing, face nail 2 -8d (242" x 0.113 ") 2 staples 13/4" - - 21 I" x 8" sheathing to each bearing, face nail 2-8d (21/2' x 0.113 ") 3 staples 13/4" - - 22 Wider than 1" x 8" sheathing to each bearing, face nail 3 -8d (21/2' x 0.113 ") 4 staples 13/4" - - Floor _ 23 Joist to sill or girder, toe nail 3 -8d (2'/2" x 0.113 ") - 24 1" x 6" subfloor or less to each joist, face nail 2-8d (242" x 0.113 ") 2 staples 13 4" - - _ 25 _ 2" subfloor to joist or girder, blind and face nail 2 -16d (31/2" x 0.135 ") - 26 Rim joist to to • • te, toe nail (roof a..lications also) 8d (21/ " x 0.113 ") .6" o.c. 27 2" .lanks • lank & beam - floor & roof) 2 -16d (3'/ " x 0.135 ") 'at each bearin 28 Built -up girders and beams, 2 -inch lumber layers - Led:er stn. su..ortin_ joists or rafters 10d (3" x 0.128 ") 3 -16d (31/ " x 0.135 ") Nail each layer as follows: 32" o.c. at top and bottom and staggered. Two nails at ends and at each splice. At each joist or rafter 29 TABLE R602.3(1)- continued FASTENER SCHEDULE FOR STRUCTURA ITEM DESCRIPTION OF BUILDING MATERIALS SPACING OF FASTENERS DESCRIPTION OF FASTENER"' c, • Edges (Inches)' Intermediate supportsG• (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and. particleboard wall sheathing to framing 30 3 /s.. _ 1'2� 6d common (2" x 0.113 ") nail (subfloor wally 8d common (21/2" x 0.131 ") nail (roof) 6 128 31 5 /1e" 1/2 6d common (2" x 0.113 ") nail ( subfloor, wall) 8d common (2'/2" x 0.131 ") nail (roof)t 6 128 32 19/32" - 1" 8d common nail (2'/2" x 0.131 ") 6 128 33 11 /8" _ 11/4" 10d common (3" x 0.148 ") nail or 8d (21/2" x 0.131 ") deformed nail 12 Other wall sheathing^ 34 1/2" structural cellulosic fiberboard sheathing 1/2" galvanized roofing nail, 7/16 " crown or 1" crown staple 16 ga., 144' long 3 6 35 25/32" structural cellulosic fiberboard sheathing 13/4" galvanized roofing nail, 7/18" crown or 1" crown staple 16 ga., 11 /2" long 6 36 '/2 "gypsum sheathings 11/2" galvanized roofing nail; staple galvanized, 11/2" long; 11/4 screws, Type W or S 7 37 5 /g" gypsum sheathings 13/4" glavanized roofing nail; staple galvanized, 15/s" long; 15 /8" screws, Type W or S 7 Wood structural panels, combination subfloor underiayment to framing 38 3/4" and less 6d deformed (2" x 0.120 ") nail or 8d common (21/2" x 0.131") nail 6 12 39 7/8" - 1" 8d common (21/2" x 0.131") nail or 8d deformed (21/2" x 0.120 ") nail 12 40 V/8"-13/4" 10d common (3" x 0.148 ") nail or 8d deformed (242" x 0.120 ") nail 6 12 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; lksi = 6.895 MPa. a. All nails are smooth- common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall have minimum average berc; rig yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank diameters larger than 0.142 inch but not larger than C.177 inch, and 100 ksi for shank diameters of 0.142 inch or less. b. Staples are 16 gage wire and have a minimum 1 /16 inch on diameter crown width. c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches orgreater. d. Four- foot -by -8 -foot or 4- foot -by -9 -foot panels shall be applied Vertically. e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). f. For regions having basic wind speed of 110 mph or greater, 8d deformed (21/2" x 0.120) nails shall be used for attaching plywood and wood structural panel roof sheathing to framing within minimum 48 -inch distance from gable end walls, if mean roof height is more than 25 feet, up to 35 feet maximum. g. For regions having basic wind speed of 100 mph or less, nails for attaching wood structural panel roof sheathing to gable end wall framing shall be spaced 6 inches on center. When basic wind speed is greater than 100 mph, nails for attaching panel roof sheathing to intermediate supports shall be spaced 6 inches on center for minimum 48 -inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall framing. h. Gypsum sheathing shall conform to ASTM C 1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM C 2(8. i. Spacing of fasteners on floor sheathing panel edges applies to rted b anel edges supported P g Ppo by framing members and required blocking and at all floor perimeters only. Spacing of fasteners on roof sheathin- ,:panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor sheath- ing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking. RECEIVED APR 16 2012 PERMIT CENTER 2009 INTERNATIONAL RESIDENTIAL CODE. TO WHOM IT MAY CONCERN: PLEASE APPLY ONLY THOSE NOTES THAT CORRESPOND TO THIS PROJECT. ALL OTHER NOTES ARE NOT APPLICABLE. THANK YOU, MEGI 2009 INTERNATIONAL RESIDENTIAL CODE® TABLE R602.3(2) ALTERNATE ATTACHMENTS WALL CONSTRUCTION NOMINAL MATERIAL THICKNESS _inches DESCRIPTION"' ° OF inches)NER AND LENGTH SPACING` OF FASTENERS Edges (Inches) Intermediate supports (Inches) Wood structural. panels subfloor, roof and well sheathing to framing and particleboard wall sheathing to framing' 4 8 up to 1/2 Staple 15 ga. 13/4 0.097 - 0.099 Nail 21/4 3 6 Staple 16 ga. 13/4 3 6 19/32 and 5/3 0.113 Nail 2 3 6 Staple 15 and 16 ga. 2 4 8 0.097 - 0.099 Nail 21/4 4 8 23/32 and 3/4 Staple 14 ga. 2 4 8 Staple 15 ga. 13/4 3 6 0.097 - 0.099 Nail 21/4 4 8 Staple 16 ga. 2 4 8 1 Staple 14 ga. 21/4 4 8 0.113 Nail 21/4 3 4 6 8 Staple 15 ga. 21/4 0.097 - 0.099 Nail 21/ 4 8 NOMINAL MATERIAL THICKNESS (Inches) DESCRIPTIONr,b OF FASTENER AND LENGTH (inches) SPACING` OF FASTENERS Edges (inches) Body of panel° inches) Floor underlayment; plywood- hardboard - particleboard' Plywood 1/4 and 5/16 11/4 ring or screw shank nail - minimum 121/2 ga. (0.099 ") shank diameter 3 6 Staple 18 ga., 7 4, 3/16 crown width 2 5 11/32 3/8, 15/32, and t/ 2 11/4 ring or screw shank nail- minimum 12'/2 ga. (0.099 ") shank diameter 6 8` 19/32,5/s, 23/32 and 3/4 11/2 ring or screw shank nail - minimum 121/2 ga. (0.099 ") shank diameter 6 8 Stale 16 a. 11/ 6 8 Hardboard' 0.200 11/2 long ring- grooved underlayment nail 6 6 4d cement - coated sinker nail 6 6 Stale 18 :a., 7/. ion: .lactic coated) 3 6 Particleboard 1/ a 4d ring- grooved underlayment nail 3 6 Staple 18 ga., '/g long, 3/16 crown 6d ring - grooved underlayment nail 3 6 6. 10 3/ s Staple 16 ga., 11 /g long, 3/g crown 6d ring- grooved underlayment nail 3 6 6 10 1/2, 5/8 s Staple 16 ga., 15/8 long, 3/g crown 3 6 For SI: 1 inch = 25.4 nun. a. Nail is a general description and may be T -head, modified round head or round head. b. Staples shall have a minimum crown width of inch on diameter except as noted. c. Nails or staples shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. Nails or staples shall be spaced at not more than 12 inches on center at intermediate supports for floors. d. Fasteners shall be placed in a grid pattern throughout the body of the panel. e. For 5 -ply panels, intermediate nails shall be spaced not more than 12 inches on center each way. f. Hardboard underlayment shall conform to ANSI/AHA A135.4. TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES'•°" MINIMUM NAIL MINIMUM WOOD STRUCTURAL PANEL SPAN RATING MINIMUM NOMINAL PANEL THICKNESS (inches) MAXIMUM WALL STUD SPACING (Inches) PANEL NAIL SPACING MAXIMUM WIND SPEED (mph) Size Penetration (inches) Edges (inches o.c.) ^ _ Wind exposure category Field (inches o.c.) B C D. 6d Common (2.0" x 0.113 ") 1.5 24/0 3/8 16 6 12 110 90 85 8d Common (2.5" x 0.131' 1.75 24/16 7/16 16 6 12 130 110 105 24 6 12 110 90 85 For SI: 1 inch = 25 4 mm, 1 mile per hour = 0.447 m/s. a. Panel strength axis parallel or perpendicular to supports. Three -ply plywood sheathing with studs spaced more than 16 inches on center shall be applied with panel strength axis perpendicular to supports. b. Table is based on wind pressures acting toward and away from building surfaces per Section R301.2. Lateral bracing requirements shall be in accordance with Sec- tion R602.10. c. Wood Structural Panels with span ratings of Wall -16 or Wall -24 shall be permitted as an alternate to panels with a 24/0 span rating. Plywood siding rated 16 oc or 24 oc shall be permitted as an alternate to panels with a 24/16 span rating. Wall-16 and Plywood siding 16 oc shall be used With studs spaced a maximum of 16 inches on center. TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING' THICKNESS (inch) GRADE STUD SPACING (inches) When siding Is nailed to studs When siding Is nailed to sheathing 3/8 M -1 Exterior glue 16 Laterally unsupported stud height' (feet) '/2 M -2 Exterior glue 16 16 For SI: 1 inch = 25.4 mm. a. Wall sheathing not exposed to the weather. If the panels are applied horizontally, the end joints of the panel shall be offset so that four panels corners will not meet. All panel edges must be supported. Leave a' /16 -inch gap between panels and nail no closer than 3/e inch from panel edges. 1 70_ . DRILLING AND NOTCHING - -STUDS PER FIGURES R602.6(1) AND R602.6(2). (INCLUDED). --- TOP PLATES BORED HOLE MAX. DIAMETER 40 PERCENT\ OF STUD DEPTH i 5/8 IN. MIN. TO EDGE NOTCH MUST NOT EXCEED 25 PERCENT OF STUD DEPTH STUD BORED HOLES SHALL NOT BE /1/°/-411°'. LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD 5/8 IN. MIN. TO EDGE IF HOLE IS BETWEEN 40 PERCENT AND - 60 PERCENT OF STUD DEPTH, THEN STUD MUST BE DOUBLE AND NO MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLED AND SO BORED For SI: 1 inch = 25.4 -mm. NOTE: Condition for exterior and bearing walls. FIGURE R602.6(1) NOTCHING a AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS NOTCH GREATER THAN 50 PERCENT OF THE PLATE WIDTH EXTERIOR OR BEARING WALL TOP PLATES For SI: 1 inch = 25.4 mm. 16 GAGE (0.054 IN.) AND 1.5 IN. WIDE METAL TIE FASTENED ACROSS AND TO THE PLATE AT EACH SIDE OF THE NOTCH WITH 8 -16d NAILS EACH SIDE FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING 71 HEADERS PER TABLES R502.5(1) AND R502.5(2). 72 FIREBLOCKING REQUIRED AS PER R602.8. AND R302.11 73 WOOD STRUCTURAL PANELS AS PER SECTION R604. '74 PARTICLE BOARD AS PER SECTION R605. 75 MASONRY CONSTRUCTION PER SECTION R606. EXTERIOR COVERING PER SECTION R703. ROOF SHEATHING PER SECTION R803. 76 77 78 BOILERS AND WATER HEATERS TO BE INSTALLED PER CHAPTER 20, 28. 79 IF GAS HEAT OR APLLIANCES ARE APPLICABLE TO THIS PROJECT THAN INSTALL PER CHAPTER 24. PLUMBING TO ADHERE TO CHAPTERS 25, 26, 27, 29, 30, 31, 32. 80 SANITARY DRAINAGE PER CHAPTER 30. 81- ELECTRICAL PER CHAPTERS 35, 36, 37, 38, 39, 40, 41. 82 ROOF VENTILATION OPENINGS SHALL BE PROVIDED WITH CORROSION- RESISTANT WIRE MESH, WITH 1/8'(3.2MM) MIN. TO 1 /4 "(6.4MM) MAX. OPENINGS. R806. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED TO 1 TO 300, PROVIDED AT LEAST 50% AND NOT MORE THAN 80% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE 10 BE VENTILATED AT LEAST 3' (914mm) ABOVE SAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY SAVE OR CORNICE VENTS. 83 DUCT SYSTEMS PER CHAPTER 16 84 COMBUSTION AIR PER CHAPTER 17. 85 CHIMNEYS AND VENTS PER CHAPTER 18. 86 ATTIC ACCESS: R807; OPENING SHALL BE PROVIDED TO ATIIC AREAS THAT EXCEED 30 SQ.FT.(2.8M) AND HAVE A VERTICAL HEIGHT OF 30° (762MM) OR GREATER. THE ROUGH- FRAMED OPENING SHALL NOT BE LESS THAN 22" BY 30" (559MM BY 762MM) AND SHALL BE READILY AUSHBLE LOCATIONER A 30' MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3. FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. 87 ROOF ASSEMBLIES PER CHAPTER 9 88 FA000ORY -BUILT CHIMNEYS PER SECTION FACTORY -BUILT FIREPLACES PER SECTION R1004. 89 MECHANICAL SYSTEMS PER SECTION N1103. 90 MECHANICAL SYSTEM MUST ADHERE TO CHAPTER 13. 91 92 93 HEATING AND COOLING EQUIPMENT MUST ADHERE TO CHAPTER 14. EXHAUST SYSTEMS MUST ADHERE TO CHAPTER 15 DRYER EXHAUST DUCTS SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER. THE MAX. LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NO EXCEED 25 FEET(7620MM) FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE MAX. LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45 DEGREE BEND AND 5 FEET FOR EACH 90 DEGREE BEND. M1502.6 94 HOOD VENT AT MIN. 100CFM INTERMITTENT OR 25 CFM CONTINUOUS. M1503, M15051 M1506„ M1507. 95. BATHROOM AND TOILET ROOMS VENTS AT MECHANICAL EXHAUST CAPACITY OF 50CFM INTERMITTENT OR 20 CFM CONTINUOUS. M1506, M1507. 97. INSULATION PER SECTION N1102. 98 ENERGY EFFICIENCY PER CHAPTER 11,, 69 STUD SIZE. HEIGHT AND SPACING SHALL BE IN ACCORDANCE WITH TABLE R602.3(5I.. .(INCLUDED) TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS° STUD SIZE (inches) BEARING WALLS NONBEARING WALLS Laterally unsupported stud height' (feet) Maximum spacing when supporting a roof - ceiling assembly or a habitable attic assembly, only (Inches) Maximum spacing when supporting one floor, plus a roof - ceiling assembly or a habitable attic assembly (inches) Maximum spacing when supporting two floors, plus a roof- ceiling assembly or a habitable attic assembly (inches) Maximum spacing when supporting one floor height' (feet) Laterally unsupported stud height' (feet) Maximum spacing (Inches) 1.20 0.75 la:i . 0 0 0.064 0.360 0.477 2 0.65 0.75 2x3° - - - - - 10 16 2 x 4 10 24` 16c - 24 14 24 3x4 10 24 24 16 24 14 24 2 x 5 10 24 24 - 24 16 24 2 x 6 10 24 24 16 24 20 24 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mrn, 1 square foot = 0.093 m2. a. Listed heights are distances between points of lateral support placed perpendicular to the plane of the wall. Increases in unsupported height are permitted where justified by analysis. • b. Shall not be used in exterior walls. c. A habitable attic assembly supported by 2 x 4 studs is limited to a roof span of 32 feet. Where the roof span exceeds 32 feet, the wall studs shall be increased to 2 x 6 or the studs shall be designed in accordance with accepted engineering practice. TOP PLATES STUD BORED HOLE MAX. DIAMETER 60 PERCENT OF STUD DEPTH 5/8 IN. MIN. TO EDGE BORED HOLES SHALL NOT BE NOTCH MUST NOT EXCEED 40 PERCENT OF STUD DEPTH LOCATED IN THE SAME CROSS SECTION OF CUT OR NOTCH IN STUD For SI: 1 inch = 25.4 mm. 5/8 IN. MIN. TO EDGE 16-1191° 1111.1.11 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS TABLE N1102.1.2 EQUIVALENT U- FACTORS" CLIMATE ZONE FENESTRATION U- FACTOR SKYLIGHT U- FACTOR CEILING U- FACTOR FRAME WALL U- FACTOR MASS WALL U- FACTORb FLOOR U- FACTOR BASEMENT WALL U- FACTOR CRAWL SPACE WALL U- FACTOR 1 1.20 0.75 0.035 0.082 0.197 0.064 0.360 0.477 2 0.65 0.75 0.035 0.082 0.165 0.064 0.360 0.477 3 0.50 0.65 0.035 0.082 0.141 0.047 0.091° 0.136. 4 except Marine 0.35 0.60 0.030 0.082 0.141 0.047 0.059 0.065 5 and Marine 4 0.3� 0.60 0.030 0.060 0.082 0.033 0.059 0.065 6 0.35 0.60 0.026 0.060 0.060 0.033 0.059 0.065 7 and 8 0.35 0.60 0.026 0.057 0.057 0.033 0.059 0.065 a. Nonfenestrati3n U- factors shall be obtained from measurement, calculation or an approved source. b. When more than half the insulation is on the interior, the mass wall U- factors shall be a maximum of 0. I7 in zone 1, 0.14 in zone 2, 0.12 in zone 3, 0.10 in zone 4 except Marine and the same as the frame wall U- factor in Marine zone 4 and in zones 5 through 8. c. Basement wall U- factor of 0.360 in warm -humid climates as defined by Figure Ni 101.2 and Table N 1 101.2. •WASHINGTON STATE: IN CLIMATE ZONE 4 MARINE SNOHOMISH, CLALLAM, CLARK, COWLITZ'.ISLAND.JEFFERSON. KING, KITSAP5 LEWIS. MASON. PACIFIC, PIERCE, SAN JUAN, SKAGIT, THURSTON,, WAHKIAKUM, WHATCOM CLIMATE ZONE 5 DRY ADAMS ASOTIN. BENTON, CHELAN, COLUMBIA. DOUGLAS, FRANKLIN, GRAYS, GARFIELD GRANT, KITTITAS, KLICKITAT, LINCOLN. SKAMANIAI SPOKANE. WALLA WALLA WHITMAN. YAKIMA CLIMATE ZONE 6 DRY. FERRY, OKANOGAN, PEND OREILLE, STEVENS, SEE TABLE N1102.1. 99 PR-30 INSULATION PERMITTED IN CATHEDRAL CEILINGS AND OVER THE WALL TOP PLATE. N1102.2. OPAQUE DOORS SEPARATING CONDITIONED' AND UNCONDITIONED SPACE SHALL HAVE A' MAN. U- FACTOR OF 0.35. ONE OPAQUE DOOR SHALL BE PERMITTED TO BE_;: EXEMPT. N1102.3.4. TABLE N1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT° CLIMATE ZONE FENESTRATION U- FACTOR SKYLIGHT U- FACTOR GLAZED FENESTRATION SHGC CEILING R- VALUE WOOD FRAME WALL R- VALUE MASS WALL R- VALUE'` FLOOR R -VALUE BASEMENT` WALL R -VALUE SLABd R -VALUE AND DEPTH CRAWL SPACE` WALL R -VALUE 1 1.2 0.75 0.351 30 13 3/4 13 0 0 0 2 0.65' 0.75 0.35i 30 13 4/6 13 0 0 0 3 0.50' 0.65 0.35`•i 30 13 5/8 19 5/13f 0 5/13 4 except Marine 0.35 0.60 NR 38 13 5/10 19 10/13 10, 2 ft 10/13 5 and Marine 4 0.35 0.60 NR 38 20 or 13 + 5h 13/17 30f 10/13 10, 2 ft 10/13 6 0.35 0.60 NR 49 20 or 13 +5h 15/19 30 g 10/13 10, 4 ft 10/13 7 and 8 0.35 0.60 NR 49 21 19/21 30g 10/13 10, 4 ft 10/13 a. R- values are minimums. U- factors and solar heat gain coefficient (SHGC) are maximums R -19 batts compressed in to nominal 2 x 6 framing cavity such that the R -value is reduced by R -1 or more shall be marked with the compressed batt R -value in addition to the full thickness R- value. b. The fenestration U- factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. The first R -value applies to continuous insulation, the second to framing cavity insulation; either insulation meets the requirement. d. R -5 shall be added to the required slab edge R- values for heated slabs. Insulation depth shall be, the depth of the footing or 2 feet, whichever is less, in zones 1 through 3 for heated slabs. e. There are no SHGC requirements in the Marine Zone. f. Basement wall insulation is not required in warm -humid locations as defined by Figure N1101.2 and Table N1101.2. g. Or insulation sufficient to fill the framing cavity, R -19 minimum. h. " 13 +5" means R -13 cavity insulation plus R -5 insulated sheathing. If structural sheathing covers 25% or less of the exterior, R -5 sheathing is not required where structural sheathing is used. If structural sheathing covers more than 25% of exterior, structural sheathing shall be supplemented with insulated sheathing of at least R -2. i. For impact -rated fenestration complying with Section R301.2.1.2, the maximum U- factor shall be 0.75 in zone 2 and 0.65 in zone 3. j. For impact - resistant fenestration complying with Section. R301.2.1.2 of the International Residential Code, the maximum SHGC shall be 0.40. k. The second R -value applies when more than half the insulation is on the interior / LOWEST DISCHARGE OPENING LISTED GAS VENT ROOF PITCH IS X/12 H (MINIMUM) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING ROOF PITCH H (minimum) ft m Flat to 6/12 1.0 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.5 0.46 Over 8/12 to 9/12 2.0 0.61 Over 9/12 tO 10/12 2.5 0.76 • Over 10/12 tO 1I/12 3.25 0.99 Over 11/12 to 12/12 4.0 1.22 Over 12/12 to 14/12 �• 5.0 1.52 Over 14/12 to 16/13 6.0. 1.83 Over 16/12 to 18/12 7.0 2.13 Over 18/12 to 20/12 7.5 2.27 Over 20 /12 tO 21/12 8.0 2.44 For SI: 1 foot = 304.8 mm. FIGURE 62427.6..4(503 6.4), 96 GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL * * * * * * * * * * * * * * * * * ** *NOTE: SEE ALSO* *THE ENGINEERING.* *THE SPECIFIC * *ENGINEERING NOTES* *AND DETAILS SHALL* *TAKE PRECEDENCE* *OVER THE STANDARD* *NOTES 8 DETAILS. bo, d REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of Tukwila BUILDING DIVISION RECEIVED APR 1 2012 PERMIT CENTER 2009 INTERNATIONAL RESIDENTIAL CODE M.E.VELTHAUSER ***DESIGNER*** 360- 886 -1442 THESE IDEAS- DESIGNS, DRAWINGS, AND PLANS ARE OWNED AND /OR ARE PRODUCTS OF M.E.GRAPHICS AND ILLUSTRATIONS (MEGI). AND THEIR USE IS LIMITED TO THE SINGLE SPECIFIED PROJECT. USE AND REPRODUCTION, WITHOUT THE CONSENT OF MEGI IS PROHIBITED BY COPYRIGHT LAWS. EVERY EFFORT HAS BEEN MADE TO AVOID INACCURACY IN THE PREPARATION OF THIS PLAN, OR DESIGN. HOWEVER MEGI CANNOT GUARANTEE AGAINST HUMAN ERROR. WRITTEN DIMENSIONS TAKE PRE- CEDENCE OVER SCALE DIMENSIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS AND DETAILS ON THE JOB SITE. THE LOCAL AUTHORITIES REQUIRE THAT IT IS THE SOLE RESPONSIBILITY OF THE USER(S) OF .THESE BUILDING:PLANS TO ACCESS, READ. UNDERSTAND &. FOLLOW EVERY BUILDING CODE CURRENTLY ENFORCED, THAT APPLIES TO THLS PROJECT. 'L.t7 - W N N aM cm. CATHY J. SPIKER 8 BRIAN FITTERER 206- 242 -8121 5145 SOUTH 168TH STREET. TUKWILA, WA 98188 CODE NOTES A. • _ice► r- I N r--I r•--I �, , HE!.WAU C MARK SHEATHING (NOTE 445) FASTENER SPACING 61 ALL EDGES (NOTES #1, #11) BOTTOM PLATE NAILING OR ANCHOR BOLTS (NOTE #3) FRAMING ANCHORS (NOTES #1, 4,8) ALLOW- ABLE SWEAR NOTES 14 1/16" MIN. APA RATED SHEATHING OR APA RATED SIDING 303 .131 "X2 -I /4" MIN. e 6" O.C. OR 14 GA. 6 6" (D.C. .161 "X3 -I/2" MIN. 6 8" O.C. OR 1/2" AB 6 5' -6" O.C. A35 6 2' -4" O.C. OR 12F3C 130 PLF 2 0° 1/16" MIN. APA RATED SHEATHING OR APA RATED SIDING 303 .131 "X2 -1/4" MIN. e 6" O.C. OR 14 GA. 6 6 " O.C. .161 "X3 -I/2" MIN. 6 6" O.C. OR V2" AB 9 3' -2" O.C. OR 5/8" AB 6 41-6" O.C. 435 Q I' -6" O.C. og. ROG 230 PLF 2 - 1/16" MIN. APA RATED 51-IEATHING OR APA RATED SIDING 303 .131 "X2 -I/4" MIN. 9 4" O.C. OR 14 GA. 6 O.C. .161 "X3 -I /2" MIN. 0 4" O.C. OR 1/2" AB 6 2' -0" O.C. OR 5/8" AB 6 3' -0" O.C. A35 6 1' -0" O.C. orz KO 350 PLF 2 ill 1/16" MIN. APA RATED SHEATHING OR APA RATED SIDING 303 .131 "X2 -I/4" MIN. 6 S" O.C. OR 14 GA. 6 S " O.C. I/4 "X5" LAG SCREW Q 1" O.C. OR 1/2" AB 6 1' -6" O.C. OR 5/3" AB 6 2' -4" O.C. 435 6 10" O.C. oa t tae, 451 PLF 2, 4, 9, 10 4 1/16" MIN. APA RATED 51-1EATHING OR APA RATED SIDING 303. " " 3" .148 X2 -I/2 MIN. �► 3 O.C. OR 14 GA. 6 2 -1/2" O.C. " �� �� 1/4 X� LAG SCREW � 6 O.C. OR I/2" AB e 1' -4" O.C. OR 5/8" AB 6 2' -0" 0.C. A35 e 8" O.C. oZ {2 1 545 PLF 2, 4, 9, 10 llo 1/16" MIN. APA RATED SHEATHING BOTH SIDES • 131 "X2 -I /4" MIN. 3" O.C. OR 14 GA. 6 3" O.C. �� „ „ 1/4 X5 LAG SCREW e 3 O.C. OR 5/S" AB � 1' -2" O.C. A35 e 6" O.C. o�iZE3C 902 PLF 2, 4, 6 .9, 10 NOTES: 1. ALL FASTENERS SHALL MEET THE FOLLOWING CRITERIA: 0.131 DIAX 2 I /4" MIN, 0.148" DIA X 2 1/2" MIN, I6d COMMON : 0.161" DIA X 3 1/2" MIN, 50 COOLER : 0.086" DIA X 1 5/S" MIN, 5d GLIB : 0.092" DIA X 1 3/4" MIN, 15GA STAPLE = 0.012" DIA X 1 1/2" MIN, 14 GA STAPLE : 0.080 DIA X 1 I /2" MIN. 2. ALL APA RATED SHEATHING AND SIDING AND PANEL EDGES SHALL BE BACKED WITH 2 INCH NOMINAL OR WIDER FRAMING AND FASTENED PER THE SCHEDULE ABOVE. PANELS MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY. SPACE NAILS AT 12" OrC. OR STAPLES AT 10" O.C. ALONG INTERMEDIATE FRAMING MEMBERS. 3. PROVIDE ALL ANCHOR BOLTS WITH 3 "X3 "X3/16" PLATE WASHERS. 4. AT GARAGE JAMBS, REFER TO LATERAL RESTRAINT PANEL DETAIL #40I. 5. PROVIDE 1/16" MIN. APA RATED SHEATHING (PLYWOOD OR 055) OR APA RATED SIDING 303 OR INNER SEAL OSB RATED PANEL SIDING ON ALL EXTERIOR WALLS DESIGNATED AS SHEARUALLS.. 6. WHERE PANELS ARE APPLIED ON flOTH SIDES OF A WALL AND NAIL SPACING IS LESS THAN 6" O.C. ON EITHER SIDE, PANEL JOINTS SHALL E OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3" NOMINAL OR THICKER AND NAILS ON EACH SIDE SHALL BE STAGGERED. 1. REFER TO TYPICAL SNEARWALL DETAILS FOR LOCATION OF FRAMING ANCHORS. SEE DETAIL #301: FOR SHEAR TRANSFER HARDWARE AT EXTERIOR SHEARWALL5 AT ROOF WHERE FRAMING IS PERPENDICULAR TO WALL SEE DETAIL *302 FOR LOCATION OF FRAMING ANCHORS AT GABLE ENDS. a AT INTERIOR SHEARWALLS AT ROOF PARALLEL TO THE TRUSSES, REFER TO DETAIL #30 TIE SNEARWALL TO ROOF TRUSS WITH FRAMING ANCHORS SPACED PER SCHEDULE OR EXTEND SNEARWALL TO ROOF AND SHEATH AND FASTEN PER SNEARWALL TYPE CALLED OUT BELOW 9. ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3X MEMBER e SNEARWALL TYPES 3 4, AND 5. FOR EXAMPLE, PROVIDE A 3X STUD AT VERTICAL JOINTS IN THE SHEATHING. 10. FOUNDATION SILL PLATES AND BO TOM PLATES OF SNEARWALL SHALL NOT BE LE5S THAT A SINGLE 3X MEMBER fp SNEARWALL TYPES 3,4, ND 5. ALSO, PROVIDE A 3X MINIMUM WIDTH MEMBER BELOW SNEARWALL TO RECEIVE LAG SCREWS SUCH A5 A 3X RIM JOIST, 3X JOIST BELOW SNEARWALL OR 3X BLOCKING BELOW SNEARWALL. 6 SNEARWALL TYPES ,4, AND 5. 11. FASTENERS AT PRESSURE PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL BE STAINLESS STEEL, G185 HDG, BATCH /POST NOT -DIP GALVANIZED OR MECHANICALLY GALVANIZED. STRUCTURAL NOTES CODES AND SPECIFICATIONS 1. INTERNATIONAL BUILDING CODE, 200q EDITION 2. INTERNATIONAL RESIDENTIAL CODE, 200q EDITION 3. SIMPSON STRONG TIE CONNECTORS AND ANCHOR SYSTEMS CATALOGS, 200q 4. FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE STAINLESS STEEL, ZM4X (GI85HDG PER ASTM 4653), BATCH /POST HOT -DIP GALVANIZED (PER ASTM 4123 FOR CONNECTORS AND ASTM 4153 FOR FASTENERS), OR MEGHANICALLY GALVANIZED FASTENERS (PER ASTM 5695, CLASS 55 OR GREATER). UNCOATED AND PAINTED PRODUCTS SHOULD NOT BE USED WITH TREATED WOOD. WHEN USING STAINLESS STEEL HOT -DIP GALVANIZED CONNECTORS, TINE CONNECTORS AND FASTENERS SHOULD BE MADE OF THE SAME MATERIAL. DESIGN CRITERIA 1. WIND LOAD 2. SEISMIC 3. ROOF LOAD 4. FLOOR LOAD 5. DECK LOAD 6. SOILS 1. CONCRETE INTERNATIONAL BUILDING CODE - 200q SIMPLIFIED METHOD, BASIC WIND SPEED : 85 MPH, EXPOSURE G' INTERNATIONAL BUILDING CODE - 2006/ SIMPLIFIED ANALYSIS, SEISMIC DESIGN CATEGORY D, I : 1.0 DL = 15 PSF LL : 25 PSF DL : 10 PSF LL : 40 PSF DL : 10 PSF LL : 40 PSF ASSUMED 1500 PSF ALLOWABLE SOIL BEARING ASSUMED 30 PCF EQUIVALENT FLUID PRESSURE FOR RETAINING WALL DESIGN ZSI PSI &r 28 DAYS GRADE 40 REINFORCEMENT MINIMUM 3" COVER FOR ALL REINFORCEMENT EXCEPT AS NOTED AT RETAINING WALLS OR OTHER DETAILS a MORTAR TYPE S TIMBER CONSTRUCTION NOTES 1. LUMBER GRADES AND ALLOWABLE STRESSES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON PLAN: ALL LUMBER, UNLESS NOTED OTHERWISE HEM -FIR #2 OR BETTER GLULAM BEAMS 24F-v4 Fb :2400 P51 1 3/4" MICROLAM, LVL E :1800 KSI Fb :2600 P51 2 11/16 ", 3 1/2 ", 5 1/4" 4 1" PARALLAMS, PSL E :2000 KSI Fb :2600 PSI 2. WHEN TOP PLATE 15 INTERRUPTED BY HEADER, HEADER SHALL NAVE STRAP CONNECTORS TO THE TOP PLATE EACH END. USE 2- SIMPSON 'MSTA24' CONNECTORS, UNLESS NOTED OTHERWISE. 3. ALL SHEAR WALL SHEATHING NAILS AND ANCHORS SHALL BE AS DETAILED ON TI-4E DRAWINGS AND A5 NOTED IN THE SHEAR WALL SCHEDULE. 4. FLOOR AND ROOF DIAPHRAGM NAILING SHALL BE Sd COMMON 6" O.C. AT ALL SUPPORTED PANEL EDGES AND ad .6 12" O.C. AT INTERMEDIATE SUPPORTS. 11 I. 2"x4" TOP PLATE 2. GARAGE DOOR HEADER 3. NAIL SHEATHING TO HEADER 9 3" O.C. EACH WAY 4. ad NAILS e 3" O.C. ALL PLATES, HEADERS AND STUDS 5. PANEL WIDTH: < 2' -l" e 9' WALL, < 2' -4" 6 8' WALL 6. 3X BLOCKING 9 ANY PLYWD. JOINTS 1. 3X PLATE S. (2) -1/2" ROUND ANCHOR BOLTS, MIN. 1" EMBEDMENT 9. APA RATED SNEATNING PER SHEAR WALL SCHEDULE 10. (2) 2X STUDS. NAIL SHEATHING TO EACH STUD 11. SIMPSON HOLDOWN PER PLAN 12. (2) #4 REBAR 13. "4 L e 16" O.G. VERTICAL - 3 MIN. 04. 6 10" O.C. HORIZONTAL - 2 MIN. 14. RAISE ELEVATION OF CONCRETE STEMWALL TO PROVIDE A MINIMUM H/W RATIO = 35 / 1. WHERE "W" = 1' -6 ", MAX. "N" = 5' -3" WHERE "W" = 2' -0", MAX. "H" = 1' -0" WHERE "W" = 2' -4 ", MAX. "H" = 5' -2" WHERE "W" = 2' -1 ", MAX. "H" = 9' -0" N 000 0 Irn W � CN et I 711 CC oe LLI 0o CL VISION DATES SOIL CONSTRUCTION NOTES I. ALL FOOTINGS AND SLABS SHALL BEAR ON UNDISTURBED SOIL OR FILL COMPACTED TO 95% MODIFIED PROCTOR 2. ASSUMED ALLOWABLE SOIL BEARING PRESSURE : 1500 PSF REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 GENERAL CONSTRUCTION NOTES City of Tukwila BUILDING DIVISION TOP OF WALL 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. ANY VARIATIONS FROM THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR THE ENGINEER RECEIVED APR 16 2012 PERMIT CENTER 2. ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION SHALL BE PROM ED. ANY PROPOSED FIELD CHANGES MUST NAVE THE APPROYL OF THE ENGINEER PRIOR TO CONSTRUCTION. 13 SCALE !r� „�.1 ki. Yib PROJECT NO. 2 11111 -(1111 11111 O • A • �6. 80 fLAII 1 I. BOTTOM PLATE NAILING PER SHEAR WALL SCHEDULE 2. 2X STUD WALL 3. SIMPSON HOLDOWN PER PLAN, FILL ALL NAIL HOLES W /I6d NAILS 4. EDGE NAILING 9 BOTTOM PLATE AND SILL PLATE 5. ANCHOR BOLTS SIZE AND SPACING PER SHEAR WALL SCHEDULE 6. "4 REBAR 16" O.C. (VERTICAL) 1. "4 REBAR 10" O.0 (HORIZONTAL) 8. (2) 14 REBAR CONTINUOUS flP. SHEAR u�p,1.1 T4 I L. 3/4" SCALE 11111 -11111 1. 2X STUD WALL 2. SIMPSON HOLDOWN PER PLAN, FILL ALL NAIL HOLES W /I6d NAILS 3. EDGE NAILING 9 BOTTOM PLATE AND SILL PLATE 4. 2X TREATED SILL PLATE ANCHOR BOLT SIZE AND SPACING PER SHEAR WALL SCHEDULE 5. *4 REBAR 16" O.C. (VERTICAL) 6. "4 REBAR 10" O.0 (HORIZONTAL) 1. (2) *4 REBAR CONTINUOUS TT T'I'. 3/4" SCALE LUALL 1. 2X STUD WALL 2. SIMPSON HOLDOWN PER PLAN 3. 2X TREATED BOTTOM PLATE ANCHOR BOLT SIZE AND SPACING PER SHEAR WALL SCHEDULE 4. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 5. (2) "4 REBAR CONTINUOUS NOTE: AT HOLDOWN, THICKEN FOOTING TO PROVIDE A FOOTING DEPTH 3" GREATER THAN ANCHOR BOLT EMBEDMENT FOR A 24" LENGTH 9 HOLDOWN I',1` E RI :R 4rHIc NE • 3/4" SCALE I. (2) 2X STUDS'; 2, 2X TREATED FJ.AT'E, FIEILf , VE.RIFYr ANcko F OL.TS PER SHEAR1 4LL',SCHEDUIV,E;: oR 4, DD DRILL IN' EXPANSION 4WCI4ORS. TQ MEET SPACING: 3. IF REQUIRED:, HOLDOui :Pt PLAN DRILL ANE EPDXY THREADED ROP TO EX151111q, FOINDATION BIZ .AND EMBEDMENT DEPTH PER f l AN 4. EDGE NAILING eQ PLATE AND SILL PL,4 5. EXISTING. FOUNDATION I0 T'1`�. SH EFAIR UJA1.1. EXISTING FOUNDATION WALL 3/4" SCALE I. gA ° PER PLAN. 2. SIMPSON. 142.5' AT EACH TRUSS 3. ROOF SEATHING 4. '2X BLOCKING W /8d 6" D.C. w4Val..hi A/G{ 5. 6HEARIUALL NAILING PER SCHEDULE lv, zse. CLl PP P 1`4#44 A614-trAjl I/ 1. BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE 2. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 3. 2X STUD WALL 4. EDGE NAILING PER SHEARWALL SCHEDULE 5. SIMPSON STRAP PER PLAN. CENTER ON RIM JOIST. (AT NT. WALL SLOT PLYWD.) 6. SIMPSON FRAMING ANCHOR PER SHEARWALL SCHEDULE (NOT REQUIRED IF PLYWOOD JOINTS ARE LOCATED AS SHOWN ON THIS DETAIL) TYPIC�41. SHE4R U.�, zm� WITH UJ,�LI. BE1.4U1 3/4" SCALE T` P. NT. WITH NO 3/4" SCALE 1. USE TOP PLATE NAILING PER SHEARWALL SCHEDULE 2. SIMPSON FRAMING ANCHOR PER SHEAR WALL SCHEDULE 3. EDGE NAILING PER SHEARWALL SCHEDULE 4. SHEATHING AND NAILING PER 5HEARWALL SCHEDULE AND PER PLAN E4#R WALL L J II EAR GU►I. I. BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE 2. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 3. SIMPSON STRAP PER PLAN. SLOT POMP. AN:? BEND STRAP 9 JOIST OR BLOCKING 4. EDGE NAILING FER SHEARWALL SCHEDULE IF JOISTS ARE PERPENDICULAR TO SHEARWALL PROVIDE (2) 2X BLOCKING BETWEEN JOISTS FOR FULL LENGTH OF SHEARWALL 1,P. INT. WITH KO 3/4" SCALE IF JOISTS ARE PARALLEL TO SHEARWALL PROVIDE DBL. JOIST UNDER SHEARWALL UJ1 DETAIL, WALL E5 E1 2 CAN t`T I 3/4" SCALE 1. SHEATHING AND NAILING PER SHEARWALL SCHEDULE 2. BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE 3. 8d 56 6" O.C. AT EACH JOIST IN CANTILEVERED PORTION 4. 8d 9 6" ON CENTER 5. A35 SIMPSON FRAMING ANCHORS PER SHEARWALL SCHEDULE OR 435F ANCHORS ON OUTSIDE FACE 1. SIMPSON ANCHOR WITH 5/8" ROUND BOLT 2. (2) 2X WALL STUD 3. 2X SHEAR WALL 4. BEAM BELOW WALL 2 ti I'OL OI 3/4" SCALE I. 2X NAILER WITH 1/2" ROUND BOLTS e 12" O.C., ALTERNATE SIDES 2. STEEL BEAM PER PLAN 3. 1/4" X 3" SIDE PLATES WITH (2)1/2" ROUND BOLTS 4. 6 "X6 ".POST STEEL BEAM POST CONNECTION 3/4" SCALE FOOTING SCHEDULE MARK SIZE DEPTH REINFORCING ALLOWABLE LOAD 18 18"x18" 8" 2#4 each way 3375# 24 24 "x24" 10" 3#4 each way 6000# 30 30 "x30" 10" 3 #5 each way 9375# 36 36 "x36" 10" 3 #5 each way 13500# 42 42 "x42" 10" 3 #5 each way 18375# 48 48"x48" 12" 4 #5 each way 24000# 54 54 "x54" 12" 5 #5 each way 5 #5 each way 30375# 37500# 60 60 "x60" 12" 66 66 "x66" 12" 6 #5 each way 45375# 72 72 "x72" 12" 7 #5 each way 54000# ote: Footing design is based on 2500 psi concrete and an allowable soil bearing pressure of 1500 psf. 1. ROOF TRUSSES PER PLAN 2. SIMPSON 'H2.5' AT EACH TRUSS 3. ROOF SHEATHING 4. 2X BLOCKING W /8d fi1 6" O.C. 5. SHEARWALL NAILING PER SCHEDULE lo, ' 1AAFW gee, 6?A%D p712' a�14- 6A-12h/AC.L /3014-s vu LY E R I �'"1 ��., T! E 61"' ETA, I1. XTEI I O 3/4" SCALE NOTE: PROVIDE SHEATHING AND NAILING PER SHEARWALL SCHEDULE OR DESIGN TRUSS AS A DRAG STRUT, REFER TO ENGINEERING FOR DESIGN FORCES �-- 3/4" SCALE 1. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 2. SIMPSON 'A35' FRAMING ANCHORS PER SHEARWALL SCHEDULE 3. 8d NAILS 6 6" ON CENTER 4. GABLE END TRUSS Lee OPTION 'A' OPTION 'i3' L BOTTOM PLATE NAILING PER SHEARWALL SCHEDULE 2. SHEATHING AND NAILING PER SHEARWALL SCHEDULE AND PER PLAN 3. SIMPSON A 4 f7Aca7 PER SHEARWALL SCHEDULE 4, 8d NAILS 9 6" ON CENTER 5. 2X FRAMING ON TOP OF LOWER WALL 6. ROOF TRUSS W144 3/4" SCALE A Nkff I. ROOF TRUSSES PER PLAN 2. SIMPSON '435' FRAMING ANCHORS PER SHEARWALL SCHEDULE 3. 2 "X4" BLOCKING BETWEEN TRUSSES 4. SHEARWALL TYPE PER 51-IEAR WALL SCHEDULE AND PER PLAN 3/4" SCALE PERIMETER SWEAR TRANSFER �i DETAIL. e EXTERIOR 6HEARWALLS 3/.4" SCALE NOTE: PROVIDE SHEATHING ANP NAILING PER SHEARWALL SCHEDULE I. SHEATHNG AND NAILING PER 51-IEARIUALL 6CNEDULE AND PER PLAN 2. SIMPSON 'A35' FRAMING ANCHORS PER SHEARWALL SCI - IEDULE 3. Sd NAILS 6 6" ON CENTER N0 (i- oII2 -1 e2AJ r1'` - Jb / (! '2, Iki H 7?7AJCI A v6 A/2 li opri,'TA/ .1O/An...} CH-0/Z4 A ,..JOE .g ' P) GABLE END DEtp4 11: 3/4" SCALE a o g� REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2012 City of Tukwila BUILDING DIVISION RECEIVED APR 16 2012 PERMIT CENTER kR 00 N 00 101 C■I et MIL N LA- W.� O oC �Y� = o •= 8= nu, REVISION DATES 03/08/2012FVD/EN6 1 EXPIRES U w 0 SCALE 3/4" ■ 1' -0" DATE DRAl1N EY PROJECT NO. SHEET NO. -2