HomeMy WebLinkAboutPermit D12-088 - FUJI TECH - OFFICEFUJI TECH 12648 INTF.RLJRBAN AV S D12-088 City oilTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 2716000030 Address: 12648 INTERURBAN AV S TUKW Suite No: Project Name: FUJI TECH Permit Number: D12-088 Issue Date: 05/14/2012 Permit Expires On: 11/10/2012 Owner: Name: EPROPERTYTAX INC DEPT #207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Contractor: Name: T C I INC Address: 13500 BEL RED RD, SUITE 9 , BELLEVUE WA 98005 Contractor License No: TCIIN* *07700 Lender: Name: Address: Phone: 206 - 433 -8997 Phone: 425 - 454 -5310 Expiration Date: 09/09/2013 DESCRIPTION OF WORK: REMOVE A NON - BEARING WALL, ADD A NEW NON - BEARING, ADD AN OFFICE WITHIN EXISTING OFFICE, AND NEW FINISHES Value of Construction: $10,000.00 Fees Collected: $464.52 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC-7/10 D12 -088 Printed: 05 -14 -2012 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Dater 1 6 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of arty other state or local laws regulating construction or the performance of work. I . authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �V Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. doc: IBC -7110 D12-088 Printed: 05 -14 -2012 7: All construction shall be done in conform a with the approved plans and the requiremof the International Building Code or International Residential , International Mechanical Code, Washingto to Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle doc: IBC -7/10 D12 -088 Printed: 05 -14 -2012 is engaged from inside the tenant space. (IF � hapter 10) of er 25: Door handles, pulls, latches, locks and operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -088 Printed: 05 -14 -2012 CITY OF TUKWILA, Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 MIN L' Vt 11. i I iN6111 10.Wei.ir% Building Permit No. ' t9 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For ofce use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION (Veil- i King Co Assessor's Tax No.: Ill t CD 0.9 - WI n -el Site Address: (2_( 1-� ��U tat AVE . 00 • Suite Number: Floor: 1 New Tenant: . Yes ❑ .. No Tenant Name: rL LII tGc 4{ Property Owners Name: iO Mailing Address: 1217.0 %b1"aubti Nei %U it Av '�uriu Its City State qg� Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: IUD KotIk Mailing Address: itii(P Nb112. I E -Mail Address: Ek Ca Keiilezrcii . tO I& Zay Telephone:'Q 4 ' 3 '2'.1 "i 4 Ua6. eiRIILO City (� II� State Zip / Fax Number: ' lb G' t4G' ' 1)3J(n 1 GENERAL CONTRACTOR INFORMATION — (Contractor information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: a Ito L Lq l �L /����t t C Mailing Address: 4tY I e Contact Person: p E -Mail Address: l0 kEttiE fel/ile 4 ar61, (p itk eativz VUro. II.Lo City State :3 Zip Day Telephonek� -x1 -8n c# Fax Number:406 - tie °9)301 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: QMpplicrdions\Fomts-Application.. On Lino\? -2M16 - Permil Application.doc Revived: 9- 211116 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): S 1t7 /CCO Scope of Work (please provide detailed information): Existing Building Valuation: S %i ki (mo.) gerINE Wow i44r u - i boo beiNci & bo GCE wii'rri4 Ws-N(3 ice, bon Pal P1ii. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: ' Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 140 C4-11& Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 14 Sprinklers 4utomatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No Ij "yes', attach list ofmateriaLs and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Soje D to Sheets. SEPTIC SYSTEM 0/4 ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:`Applieadenartmo•Applicuionn On Lircll•2006 • Permit Application.doc Rcaiwd: 9-206 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure Type of Construction per Type of Occupancy per IBC l'" Floor y,tre G�(y"� J I O MIA L A WA `' f�IBC Y -e 1. Q V 2nd Floor 3`d Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: ' Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 140 C4-11& Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 14 Sprinklers 4utomatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No Ij "yes', attach list ofmateriaLs and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Soje D to Sheets. SEPTIC SYSTEM 0/4 ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:`Applieadenartmo•Applicuionn On Lircll•2006 • Permit Application.doc Rcaiwd: 9-206 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW 'ER O ' . !�•`:� RIZED AGENT: Signature: Print Name: Mailing Address: 14 et IQ Date: O17 L I LP I ( z_ Day Telephone: "GV rQ -433 klArcc I c.P City State Zip Date Application Accepted: Date Application Expires: Staff Initials: QMpplkarionsWorms- Applications On LineU -211116 - Permit Application doc Revised: 9 -21)16 bh Page 6 of 6 • • �J� %La wqs City of Tukwila C � � y O Z `i O 1.908' Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.eov RECEIPT Parcel No.: 2716000030 Permit Number: D12-088 Address: 12648 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 03/16/2012 Applicant: FUJI TECH Issue Date: Receipt No.: R12 -01574 Initials: User ID: WER 1655 Payment Amount: $283.30 Payment Date: 05/14/2012 09:17 AM Balance: $0.00 Payee: GREGORY HOFMAN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 01560Z ACCOUNT ITEM LIST: Description 283.30 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $283.30 278.80 4.50 doc: Receipt-06 Printed: 05 -14 -2012 il • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2716000030 Permit Number: D12-088 Address: 12648 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 03/16/2012 Applicant: FUJI TECH Issue Date: Receipt No.: R12 -01072 Initials: WER User ID: 1655 Payment Amount: $181.22 Payment Date: 03/16/2012 09:56 AM Balance: $283.30 Payee: DAVID KEHLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 08196D ACCOUNT ITEM LIST: Description 181.22 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 181.22 Total: $181.22 doc: Receipt-06 Printed: 03 -16 -2012 INSPECTION RECORD , Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G '6300 Southcenter Blvd., #100, Tukwila. WA 98188 11; (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 3;r2 -©gg Proj t` P. , . a ru t1 1•e64.∎\ Type o ipection: ,hjAA g,: tD 1 ^G Address` 1v - ' TAT-efJ.ff Date Called: Special Instructions: • - Date Wanted: . /a.ma '30 -(z (( m. :/ Requester: No: 7,0 4 — 5d41 -Z635.0 (Approved per applicable codes. a Corrections required prior to approval. • COMMENTS: pefitkr-i.okvoie,1-e Inspectd {: jiLA Date: 0 ! f 2- ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA' BUILDING DIVISION Cam' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 iL-- D12 -_O8 Pro t (g Type tlns�pec -k (? p Address: g _„C 7t J1GADaje Caller Special Instructions: Date Wanted:. /,a.rr .. Requester: Phone Nf: ` r%-4�A! q0q- 2636 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: • 6 K r- SJ& c `rte Pre r I erg\. 1 Ins ector: \) Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ►� -,9811 INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Pr 'et:. Type nspect'on:` r Address „r TertJria Date Called: Special Instructions: Date Wanted• -r -- /ate (3----11-- p.m. Requester: Phone 42I Qi �..zAi3c Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0K (-7.oJ- - 3aVecT 1 e4 r: t ,D r _o e ------ '4- -0, SCie ■ s 0 J iI. Mr toL -k , cor!0 • ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1 /z_�_a€ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 I/o/N Project: F u) Tc� k` Type of Inspection: i-, •� c.. F....... / Address: / z e,-/&.. Suite #: Suite r45 Contact Person: /- ..,F i 141a/._ 40--c .s• -IL.. Special Instructions: /v Phone No.: ©G 5" o7 Zv3G Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: Fire Alarm: / � /� / ez, ..,F i 141a/._ 40--c .s• -IL.. Monitor: /v .fr-,7'te e4 le* ,1 w-• Permits: Occupancy Type: s � %B7 . Needs Shift Inspection: Sprinklers: Date: Fire Alarm: Hood & Duct: / Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: G,-o9 rj Date: glz rh 2_ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamil E`n:veaope Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address Project Description jmit I.I1"EIZ lekr I Ate tal Applicant Name: aq to Applicant Address: Hi (.e Ivtlbi f2 2 cca• Applicant Phone: UV , 4-33 het r�Il�oIlz9- ❑ New Building titeigh ❑ Addition ..Alteration Compliance Option Prescriptive ❑ Component Performance See Decision Flowchart (over) for qualifications) Occupancy Group Climate Zone Nonresidential 0 Multifamily Residential it Climate Zone 1 0 Climate Zone 2 ( See WSE( Fenestration Area Calculation Total Fenestration (rough opening) (vertical & overhd) Semi - Heated Path O yes no Electronic version: divided by these values are automatically t. Gross Exterior Wail Area Allowable if project meets all requirements as defined in section 1310.2. Only calculated separately from other conditioned spaces. Limited to reduced wall i and qualifying thermostat. Envelope Requirements (enter values as applicable) Minimum Insulation R- values Roofs - Insulation Above Deck Roofs - Metal Building Roofs - Single Rafter Roofs - Attic and All Others Walls - Mass Walls - Metal Building Walls - Steel Framed Walls - Wood Framed and Other Floors - Mass Floors - Steel Joist Floors - Wood Framed and Other REVIEVWELI r R CE DING DIVI ON Maximum F- factors Slabs -on -Grade - Unheated Slabs -on -Grade - Heated Notes: L16 E4'2 1E 1541 1.-010 l EN4E1. ey� Envelope Requirements Vertical Fenestration Non -Metal Frame Metal Frame Entrance Door Skylights - Without Curb Skylights - With Curb Opaque Doors - Swinging Opaque Doors - Non -Swir Vertical Fenestration Non -North North Skylights RECEIVE MAR 16 2012 PERMIT CENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential interior Lighting) Summary. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Info Project Address Applicant Name: Applicant Address: Applicant Phone: /eke . { U. i1'EG Rt. -'IetI1/ Project Description ❑ New Building ❑ Addition LTG -INT Revised November 2010 DateaJ For Building Department Use Alteration ❑ Plans Included COpy Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Lighting Wattage ..— , ..... ____ _ ___ Location (flooriipllan /room #) _ ..., •- - Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area I'' /lit g) //,.+ C1ll - 19,41i °# From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed '' OM`LI• ":O ED MAR 2 a g 2 City ofTu. BUILDING Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. 7 -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable. the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number. and leave Watts /Fixture blank. o e8 ECEI V ED MAR 16 2012 PERMIT CENTER, Li,g Min g,• Motor, and- Transformer: Permit Plans Chiecklist • ` TG CHK 2009 Washington State Energy Code Compliance Forms for Nonrestdenttal and Multifamily Residential Revised November 2010 Project Address 1446 I uttekta 4v�t' {Dat tkp h) -, II The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State No esldential Energy Code. Applicability (yes, no,�?�a.) ,,@octet ' Sectiorl` �` , Component • •-• - ~ formation Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) •, 1513.1 Local control /access Schedule with type, indicate locations "t-`� 1513.2 Area controls Maximum limit per switch fir 1513.3 Daylight zone control Schedule with type and features, indicate locations -rz ' vertical glazing Indicate vertical glazing on plans 1r22.s �I overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w /backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Hotel /motel controls Indicate location of room master controls 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS Section 1514) 1514 `Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) V ) 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture IN- 1532 Exterior Lighting Summary Form Completed and attached. Schedule ?with fixture types, i lamps ;ballega4lattT pef flzture 1 MOTORS Section 1511 1 > 1. MOJ pus• »u 1 A 1511 Elec motor efficiency MECH -M01j o E0i0t 51 Schedule with hp, rpm, efficiency TRANSFORMERS Section 1540 ; 1540 Transformers In icate siie alt. efficie -r If "no" is circled for any question, provide explanation: fiiW)u'f io X11 • VtO1?,1Vta RECEIVED MAR 16 2012 PERMIT C NTEP • PEI�Nl4� t� ►' y PLAN REVIEW /R � TING SLIP ACTIVITY NUMBER: D12 -088 PROJECT NAME: FUJI TECH SITE ADDRESS: 12648 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # DATE: 03 -16 -12 Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS- uildin • • (vision 'ublic Works orrn G-U Alri6Orb 21'1(1—AL /U,/A- ire Prevention anning D vision Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 03-20 -12 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-17 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing stip.doc 2 -28 -02 Joanna Spencer From: Todd Reedy Sent: Wednesday, March 21, 2012 8:32 AM To: Joanna Spencer Subject: RE: TI @ 12648 Interurban Ave S D12 -088 Good morning Joanna, 12648 Interurban (Gateway Corporate Center Bldg 3) is current on all backflow preventer installation and testing. Have a great day, Todd From: Joanna Spencer Sent: Tuesday, March 20, 2012 5:20 PM To: Todd Reedy Cc: Joanna Spencer Subject: TI @ 12648 Interurban Ave S D12 -088 Hi Scott, Are they current on their backflows ? Thanks, Joanna Phone: (206)431 -2440 Fax: (206)431 -3665 Joanna.Spencer@TukwilaWa.gov /www.TukwilaWa.gov PERMANENT FILE COPY D12 -088 1 Contractors or Tradespeople Pfter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name T C I INC UBI No. 601481013 Phone 4254545310 Status Active Address 13500 Bel Red Rd. #9 License No. TCIIN "07700 Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 9/20/1993 State WA Expiration Date 9/9/2013 Zip 98005 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TALBOTI080P8 TALBOTT T I Construction Contractor General Unused 10/28/1992 10/28/1993 Archived Business Owner Information Name Role Effective Date Expiration Date TALBOTT, PAUL DOUGLAS President 01/01/1980 Bond Amount CITOLI, PAUL J 4 01/01/1980 09/09/2011 TALBOTT, KAY E Until Cancelled 01/01/1980 09/09/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Hanover Insurance Company, The 1959106 09/07/2011 Until Cancelled $12,000.0009/13 /2011 3 INS CO OF THE WEST 1717463 09/07/2001 Until Cancelled 09/07/2011 $12,000.00 08/28/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 10 American Fire & Casualty Co BKW52997183 09/07/2011 09/07/2012 S1,000,000.0008/03/2011 9 WEST AMERICAN INS CO BKW52997183 09/07/2010 09/07/2011 $1,000,000.0007 /26/2010 8 WEST AMERICAN INS CO BKW52997183 09/07/2009 09/07/2010 $1,000,000.0009 /08/2009 7 OHIO CASUALTY INS CO BK052997183 09/07/2005 09/07/2010 $1,000,000.00 07/30/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx V 05/14/2012 REVISIONS I No changes shall be ma a to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittet t and may include additional plan review fees. i NOTES: 1. REMOVE EXISTING WALLS AS SHOWN. PATCH AND REPAIR FLOOR, WALLS AND CEILINGS. 2, CAP ALL REMOVED ELECTRICAL IN J -BOX ABOVE CEILING OR AT ROOF, MARK FOR PANEL AND CIRCUITS. EX. DEMISING WALL --� EXISTING OFFICE IS HEATED AND COOLED NO CHANGES TO ENVELOPE EX. WAREHOUSE SEMI - HEATED MAX 8 BTU /SF eS EXIT EX. ELEC. PANEL EX. RR EX. ENERGY CODES NOTES: 1) NO CHANGE TO EXISTING BUILDING ENVELOPE 2) LIGHTING EXEMPT - LESS THEN be% OF FIXTURES ARE NEW AND INSTALLED WATTAGE IS NOT BEING INCREASED NOTE: 1 RE- DISTRIBUTE HVAC IN NEW SPACES (SEPERATE PERMIT) 2. MODIFY SPRINKLER SYSTEM TO MAINTAIN FULL PROTECTION (SEPERATE PERIT) EX. EXIT DOOR FROM ADJACENT TENANT SPACE ____(.7(_1_ EX. DEMISING WALL TH FLOOR FLAN: DEMO SCALE: 1 /8" : 1' -0" REMOVE EXISTING WALL REPAIR GRI EX. RECEPTION EXIT OVERALL AERA:4,86.3 SF OFFICE AREA : 1,911 SF WAREHOUSE : 2,88e. SF 1J (6$ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 3 2012 City of Ila BUILDING %VISION i VICINITY MAP Scale: NOT TO SCALE SEPARATE PERMIT REQUIRED FOR: Mechanic& Electrical Plumbing Gas Piping City of Tukwila , BUILDING DIVISION LIGHTS TO BE REMOVED AND RELOCATED TYP. 4/ REMOVE AND RELOCATE EXISTING LIGHT REMOVE AND RELOCATE EXISTING LIGHTS IF NOT ALREADY MOVED. T SECONDARY DAYLIGHT ZONE AT 18' BEYOND PRIMARY ZONE. REMOVE EX. WALL, PATC4 -4 AND REPAIR GRID AND WALLS PRIMARY DAYLIGHT ZONE AT 9' INWARD. TH ELECTED CEILING: DEMO SCALE: vs° , 11_0.. NOTES: 1. PROVIDE MULTI LEVEL SWITCHING IN NEW OPEN SPACE PER CODE. 2. REMOVE EXISTING SWITCHING AND RE SWITCH NEW OPEN SPACE AT FRONT WALL (3 WAY, MULTI- LEVEL) 3, RELOCATION OF LIGHTS, NO INCREASE IN WATTAGE, BUILDING 4 SITE STATISTICS BUILDING CODE: ZONING: SEISMIC ZONE: CONSTRUCTION TYPE: IBC 2009 M -1 ZONE 3 V -B SPRINKLERED OCCUPANCY GROUPS: B 4 5-1 ALLOWABLE BUILDING AREA: 3 SIDE SETBACK FOR AREA AND FULLY SPRINKLERED COPY AREA OF TENANT : 4,863 SF FILE AREA OF REMODEL: 1,000 SF No�� 12-"Oft, OCCUPANT LOAD : 20 OFFICE + 6 WAREHOUSE = 26 OCCUPANickm ieviewsppromilssubledbannaidarketla Approval of contraction documsts does nct authorize the, viote�on of any adopted code or owe. Receipt et Copy 1sadmowledged: TAX ID. # 211600- 0010 -09 LEGAL DESCRIPTION Of •WLDING DIVISION LOT 3, GATEWAY CORPORATE CENTER, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 144 OF PLATS, PAGES 23, 24 AND 25, IN KING COUNTY, WASHINGTON; EXCEPT THAT PORTION, IF ANY, DEEDED TO THE CITY OF TUKWILA FOR SIDEWALK BY DEED RECORDED UNDER NUMBER 9303171767; TOGETHER WITH A NON- EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS CREATED BY INSTRUMENT RECORDED UNDER RECORDING NUMBERS 9312222125 AND 9312222126, IN KING COUNTY, WASHINGTON. SEPARATE PERMITS 1. MECHANICAL AND PLUMBING 2. SPRINKLER 3. ELECTRICAL 4. FIRE ALARM RECEIVED MAR 202012 TUKWILA PUBLIC WORKS SCOPE OF WORK REMOVE EXISTING NON- BEARING OFFICE PARTITION AND ADD A NEW WALL AND A NEW OFFICE, MODIFY EXISTING LIGHTING TO ACCOMODATE NEW PLAN AND INSTALL NEW FINISHES. MODIFY I-1VAC, SPRINKLER, AND ELECTRICAL AS REQUIRED FOR NEW CONSTRUCTION UNDER SEPARATE PERMITS. RECEIVED MAR 16 EI 2012 PERMIT CENTER 1 co O 0. m 0 w 0 W 1— 0 z 0 a. 0 v0 0 0 03 00 E O N N w i 4 WASHINGTON t n� %.r ,TEr,- i7,c. a e I'. ,r 7, .n ;; r,., ti ... .. _ � L.,�V I.r:_.,1•.. ,, � a_ -_�". V' � L�'..�� _ ..,�1�a_ Lv'1�lI.J i � .V i J�iUV�� 3/15/2012 2:20:13 PAINT BLACK 3/4" x 2" FILLER BLA GASKETS 1/4" EACH SIDE OF FILLER UJALL TO MULLION SILL BELOW DEEP LEG TRACK ATTACH 9 SILL AND CEILING - DO NOT ATTACH GYP. BD. TO TRACK STEEL STUD - ATTACH GYP. BD. TEL STUD - WALL RETURN TO WALL SCALE: I -1/2" : 1' -0" SECTION EXIT TRAVEL PATHWAY 63 LF 1 1 1 1 1 1 1 1 1 1 1 -1-- 1 1 WA-'EHIOUSE 1 2,06& SF AT 1/500 = 1 6 O CUPANTS 1 ON EXIT 1 1 MAX TRAVEL DISTANCE NOT 1 TO EXCEED 100 LF FOR COMMON 1 PATH OF TRAVEL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SMOOTH HOLLOW METAL JAMB (PAINTED) CAULK BOTH SIDES 5/8" GYP. BD. BOTH SIDES OVER STEEL STUD WALL 1/4" SAFETY GLAZING HOLLOW METAL JAMB UJINDOUJ AND DOOR JAMB SCALE: I -1/2" : I' -0" NEW OPEN 'FFICE 01 1,911 SF 61/100 =20 OCC. EXISTING ADA RESTROOMS 0 EXIT TR • VEL PATHIUJA 50 LF Ex. OFFICE 4 1 EX. OFFICE 3 NEW OFFICE e11111•111111 EX. OFFICE 2 SINGLE EXIT 1 ALLOWED, MAX. 1 TRAVEL DISTANCE IS 0 LF �♦ ,14xo 0 Tf 0 Q E I 14' 49' NEW STUD WALL TH NO CHANGE TO BUILDING EM--eEt FLOOR PLA SCALE: 1 /5•• = I'_0" = 4,863 SF w 03 -13 -12 SECTION FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE I2ga. WIRES SPLAYED 6 45 TO AN EYE SCREW ROOF AND TOP OF UAL +6" AFF 1/4" SAFETY GLAZING HOLLOW METAL JAMB 2x BACKING CAULK BOTH SIDES 5/8" GYP. BD. BOTH SIDES OVER STEEL STUDS WINDOW SILL - JAMB SIM. SCALE: 1 -1/2" : 1' -0" SECTION v■■■■s■■UUU■■fluIU" 1•UPII•■■■Uk I, ATTACH TOP RUNNER TRACK TO CEILING GRID WITH 2 - +ro x 1 1/8" LONG SCREWS AT 2' -0" O.C. TYPICAL STUDS WALL PER SCHD. (FOR WALL INSULATION SEE PLAN) 5/8" GYP. BD. EA SIDE (FLUSH FINISH). SEE REFLECTED CEILING PLAN TYP. WALL TO REFLECTED CEILING SCALE: 1 -1/2" : I' -0" TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR U/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED I" EMBEDMENT AT 24" O.C. RUBBER BASE * CARPET _'�►- 5/8" GYP. BD. ACOUSTICAL BLANKET SOUND WALL. CONC. SLAB ON GRADE WALL TO SLAB CAULK GYP. BD. TO FLOOR 6 ALL SOUND AND INSUL. WALLS SECTION SCALE: I -1/2" : I' -0" SECTION 4 WOOD DOOR HOLLOW METAL DRY WALL FRAME 5/8" GYP. BD. BOTH SIDES STEEL STUDS INTERIOR DOOR JAMB SCALE: I -1/2" : I' -0" NOTE: FRAMES AND DOORS TO MATCH EXISTING LEGEND: EXISTING WALL TO REMAIN EXISTING TO BE REMOVED NEW METAL STUD WALL INFILL, INSULATED, 5/8" GYP. BD. ON EACH SIDE (SEE WALL TYPE. NEW DOOR EXISTING DOOR I' x S' EXISTING 2 -TUBE FLUORESCENT (110 WATTS) 2' x 4' EXISTING 3 -TUBE FLUORESCENT (88 WATTS) 2' x 4' EXISTING 3 -TUBE FLUORESCENT TO BE RELOCATED (88 WATTS) 2' x 4' NEW OR RELOCATED 3 -TUBE FLUORESCENT (SS WATTS) u u u' EXISTING RESTROOM LIGHT EXlll E ILLUMINATED EXIT SIGN 0 DUPLEX OUTLET 1201U FOURPLEX OUTLET 120W • WALL TELEPHONE OUTLET, MUDRING, CONDUIT, AND PULL STING ONLY $ ELECTRIC SWITCH REVIEWED FOR CODE COMPLIANCE APPROVED MAR 232012 City of Tukwila BUILDING DIVISION EXISTING LIGHTING T NO CHANGE IN WATT RELOCATED LIGHTS NO CHANGE IN WATTAGE TYP. DOOR SCHEDULE: (LEVER HANDLES ON ALL DOORS) RELOCATED L DOOR EI,E1: DOOR E2-E4: DOOR E5,E6: DOOR ES: DOOR E9,E11: DOOR Elm: NEW DOOR 1: EXISTING STOREFRONT DOORS EXISTING 3'X1' 5C WOOD WITH METAL JAMB, LOCKSET, NO CHANGES EXISTING 3'X7' SC WOOD WITH METAL JAMB, PRIVACY LOCK, NO CHANGES EXISTING 3'X1' SC WOOD WITH METAL JAMB, LOCKSET, WEATHERSTRIP, CLOSER, NO CHANGES EXISTING 12'X14' DRIVE IN DOORS, NO CHANGES EXISTING 3'X1' R MTL DOOR AND FRAME, LOCKSET(INSIDE EXIT, NO SPECIAL KNOWLEDGE).ANGES NEW 3'- 0 "X1' -0" SC WOOD DOOR (STAINED) AND N. MTL. FRAME, LEVER HANDLE LOCKSET (INSIDE EXIT, NO SPECIAL KNOWLEDGE). WALLSTOP, SILENCER (MATCH EXISTING) ROOM FINISH SCHEDULE: FLOOR: NEW CARPET 1, -4 WALLS: PAINTED GYP. BD. - REPAINT 8 BASE: NEW RUBBER CEILING: EXISTING SUSP. ACOUSTICAL, CLEAN AND REPAIR DAMAGED GRID AND REPLACE DAMAGED TILES. 5,6 FLOOR: REFURBISH, NEW SHEET VINYL BASE: NEW SHT VINYL COVED 6" WALLS: EX. GYP. BD.- REPAINT (SGE) NEW P. LAM. WAISNCOT +4' CEILING: EX. GYP BD. RE PAINT FLOOR: RESEAL CONCRETE BASE : NONE U.I.A4.1.5: P,A!NT ('~F) CEIi iF,l' -. 11 WALL TYPE: (MATCH EXISTING) 3.5/8 "X 25 GA. AT 24" O.C. STEEL — STUDS SOUND INSULATE FULL THICK, %a" GYP. BD. EACH SIDE (PAINT) WINDOW SCHEDULE NEW RE -LITE, 2' -0" X 1' -0" AT +6" AFF, H. MTL JAMB (MATCH DOOR JAMB), I/4" CLEAR SAFETY GLAZING ' 11 i �.: At Ivy_ j ,f1: N T REMAIN GE x • SECONDARY DAYLIGHT ZONE AT 18' BEYOND PRIMARY ZONE. PRIMARY DAYL 1G-4T ZONE AT 9' INWARD. 111 RELOCATION OF EXISTING WATTAGE TH EFLECTE CE IL= I SCALE: 1/8" = 1' -0" LIGHTS, NO CHANGE G FLAN \E RECEIVED MAR 16 2012 PERMIT CENTER IN 01 co c0 1 1 N 0 z E--I z z W U H 0 WASHINGTON '',Mi t \\ 1ocurnents',CAD\1937 1 959 8704- 3`iFUJITEC 12648\12648 PLUS 12652 COMB 10- 26- 10.dwg,1 2, 3/15/2012 2:20:45 PM 2524 ?Et a a 1 bA1 E. !:FREE 1,11 N t A 814 3Y KE; 8 BY H. o n DESCRIPTION SUBMIT FOR PERMIT (V : o i Q M cn 01 co c0 1 1 N 0 z E--I z z W U H 0 WASHINGTON '',Mi t \\ 1ocurnents',CAD\1937 1 959 8704- 3`iFUJITEC 12648\12648 PLUS 12652 COMB 10- 26- 10.dwg,1 2, 3/15/2012 2:20:45 PM