HomeMy WebLinkAboutPermit D12-089 - WESTFIELD SOUTHCENTER MALL - MUCHO BURRITO - LANDLORD IMPROVEMENTMUCHO BURRITO 971 S OUTH CENTER MALL D12-089 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 971 SOUTHCENTER MALL TUKW Suite No: Project Name: MUCHO BURRITO Permit Number: D12-089 Issue Date: 05/24/2012 Permit Expires On: 11/20/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WY SW, SUITE 200 , SEATTLE WA 98106 Phone: 206 - 624 -2777 Contractor: Name: MODCO DESIGN LLC Phone: 716 697 -4354 Address: 16125 JUANITA WOODINVILLE WY #702 , BOTHELL, WA 98011 Contractor License No: MODCODL895LT Expiration Date: 06/30/2013 Lender: Name: Address: DESCRIPTION OF WORK: DEMOLISH EXISTING TENANT SPACE, CONSTRUCT NEW STOREFRONT FOR FUTURE TENANT Value of Construction: $75,000.00 Fees Collected: $2,009.09 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -089 Printed: 05 -24 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N N N • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. The granting of this permit does not pre construction or the performance of work to this permit. Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development permit and agree to the conditions attached Date: S/ li ace NAO,ro �q^_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12 -089 Printed: 05 -24 -2012 this requirement. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 min) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: IBC -7/10 D12 -089 Printed: 05 -24 -2012 26: All new sprinkler systems and all modifons to existing sprinkler systems shall have department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 33: Post address on storefront per approved Westfield standards. 34: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 36: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 37: Since any food preparation requires installation of a grease interceptor, Mucho Burrito shall install a grease interceptor or obtain Mall permission to tie into the existing outside grease interceptor installed for previous Johnny Rockets restaurant if feasible when application for interior tenant improvement is filed. Applicant shall contact Mr.Mike Cusick, P.E., Public Works Senior Sewer Engineer at (206)431 -2441 to discuss grease interceptor requirement. doc: IBC -7/10 D12-089 Printed: 05 -24 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCA ". . King Co Assessor's Tax No.: 12c24{ 7 -001() Site Address: 1 S D L 11 fC.e.1...TtYL l�t\/i�t,.frr Suite Number: ZS' (c Floor: Tenant Name: t.Ct LA. Property Owners Name: k E A %,b Mailing Address: 2100 5Ol lj .0. 1I - MAUL- A X81 v v , City State Zip New Tenant: VAci...Yes ❑ ..No Name: WtA t -tb5 11-(01\ Day Telephone: T7%% Mailing Address: '{ t-'c L-12.4 111,k3 SUS SONci 1 1A1-- WA 5 c' to City State Zip Fax Number:204- 62- -( E -Mail Address: -tom 1■1(.4 -SMS'f izerF'EA. afDi''t GENERAL Inform: �NTRt iG'TOR INFORMATION - Information %r Mecbaa ical (pg 4} #kir Plumbing'and Gas. Piping (p$ S}' Company Name: / '7 p G i t! (i 4r 5 17 "i Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: State Zip Expiration Date: 5.M. Sr Ptv- ,�i�- r�f��/S c.-i-e — '(O b/2 ,A 144" Sit l 12i Sell -7724' q '/0 - / / City States �/ Zip l�l /tf j)047171.1156 '^ Day Telephone: 2 • 02'7 ' 2. % %7 E -Mail Address: kill+-7,/ e----5./454Thrie,3641 . £611 Fax Number: 20(... ' 62-Y • 2 ' ? 3 ENGIN1 ER'OF`RECO niust be w. stam by Engineer'of Record Company Name: Mailing Address: Contact Person: E -Mail Address: Q: Wpplications\Forms- Applications On Line13 -2006 - Permit Application. doc Revised: 9 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 D G p �ION- 206 -43 Valuation of Project (contractor's bid price): $ 75, 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): .25191170(.../ SR b7(1,577/4/ 12:5-41/4-4.(7- 7 ,tf 4 4S/- � ?z —E c i S772Gf C7_,. /Vela L$f _4.,T 77t, Will there be new rack storage? ❑ Yes y.No If yes, a separate permit and plan submittal will be required. 60,, 7 z t/3"7 Additii I~xist Strucl pe M M Aces S1 Attached c PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: /l(/� Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm Compact: Handicap: No If "yes ", explain: None Other (specify) Will there be storage or use o i,rdble, cbmbustiblh or hazar ud materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safeta Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 0 OTES Applicable to ail per pplicatio Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED E T: Signature: `1/� < c, Date: '3/1 ' % Z-- Print Name: /u� - -J 4L�S� Day Telephone: 2 2}� 2? < Mailing Address: VDlno pelPia6 1.414-r Ski `t 2 5 ki'TLI f /,s,{/ -� `!'8/V 6 City State Zip Date Application Accepted: q— r r C—/) Staff Initials: C "/ Q: Wpplications\Forms- Applications On Linel3 -2006 - Permit Application. doc Revised: 9 -2006 bh Page 6 of 6 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-089 Address: 971 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/19/2012 Applicant: MUCHO BURRITO Issue Date: Receipt No.: R12 -01688 Payment Amount: $1,219.40 Initials: JEM Payment Date: 05/24/2012 02:09 PM User ID: 1165 Balance: $0.00 Payee: JACOB MOROSHAN, MODCO DESIGN LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 049182 ACCOUNT ITEM LIST: Description 1,219.40 Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,219.40 1,214.90 4.50 doc: Receiot -06 Printed: 05 -24 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-089 Address: 971 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/19/2012 Applicant: MUCHO BURRITO Issue Date: Receipt No.: R12 -01086 Initials: User ID: Payee: WER 1655 Payment Amount: $789.69 Payment Date: 03/19/2012 04:22 PM Balance: $1,219.40 S M STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16542 789.69 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 789.69 Total: $789.69 doc: Receiot -06 Printed: 03 -19 -2012 INSPECTION RECORD Retain a copy with permit INS TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter- Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 .6 /2 -0c5 2 Project: w '/1'6 / ?? /fry/ 72 Type of Inspection: /fTivil L, fr''../) th, --.•a1 i'i <4sss P /ok 04/Ant ,1-76944t/r41 Address: c 7/ 60 An- n 1/7/ ' Date Called: Special Instructions: ``� CIC A Q� \ Date nted :. V —a7 -i2. a.m. Requester: Phone No: 7/V 6q7 4/33/ pproved per applicable codes. El Corrections required prior to approval. 7 COMMENTS: fr''../) th, --.•a1 i'i <4sss P /ok 04/Ant ,1-76944t/r41 t- '.ti "91 pecto PECTION FEE REQ Date RED. Pr'or to next inspection: fee must be at 6300 Southcente Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: VIA IX 14 boRi- t 0 Type of Inspection: c., LAza -Ni G Address: 0-1"7 •t Soe,u-r nAtk Date Called: Special Instructions: Date Wanted:. _ 4- - t'z ��,' p.m. Requester: Phone No: - 71L{ -u1' -Li35y Approved per applicable codes. El Corrections required prior to approval. r COMMENTS: Date Fri REI 1SPECTION FEE REQUIRED. Prior text inspection, ee must be pai'd at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ti • -a INSPECTION RECORD I Orf Retain a copy with permit-IV I INSPECTIOt1 NO. PERMIT NO. CIY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431 -3670 Permit inspection Request Line (206) 431 -2451 Project: ` 1 rrt to Type ojJn peption:a .UtAC, Address: 71 Sc ( Special nstructions: Date Called: Date Wanted:. � .m) -4 -( 2__. p.m. Requester: Alone No: 4 - X57 - 3S Approved per applicable codes. Corrections required prior to approval. k COMMENTS: Ins,pgctor: Date: 1 4- REINSPECTION FEE REQ b IRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b /c}-17? ):j PERMIT NUMBERS CITY OF TUKWILA FIRE .DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: M ueA O 'Icy. rir 1 Type qf Insp €tion: roc- /AvXbu --4 Address: q-71 S c. li" t -t Suite #: Contact Person: Special Instructions: • Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: birx..4 12)1, Deaf. UI oil (.9- Nv — OK ..--'1 NA-4.- .r_ - _. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: A Inspector: / S?- Date: Qua y// z Hrs.: r $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit O g PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: - - T Type of nspection: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /4-ek lev;'ee =61,51pc- eyi Hkt& p/ (,s aw Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspector:/ , ,.1,, con- -- Date: c'f a ',// Z Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • •` • • : *PERMIT GOND PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -089 DATE: 03 -19 -12 PROJECT NAME: MUCHO BURRITO SITE ADDRESS: 971 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPARTMENTS: Division Public Works AviC, Obite Fire Prevention tanning i ion Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -20 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -17 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page eti si 0 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MODCO DESIGN LLC UBI No. 603098736 Phone 7146974354 Status Active Address 16125 Juanita Woodinville Way License No. MODCODL895LT Suite /Apt. #702 License Type Construction Contractor City Bothell Effective Date 6/30/2011 State WA Expiration Date 6/30/2013 Zip 98011 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MOROSHAN, JACOB Partner /Member 06/30/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AEGIS SECURITY INSURANCE COMPANY 520574 06/20/2011 Until Cancelled $12,000.00 06/30/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Nevada Capital Ins Co 77 NPP 4 025711 05/02/2012 05/02/2013 $1,000,000.0005 /11/2012 2 Red Shield Ins CNT 017338 10/11/2011 10/11/2012 05/22/2012 $1,000,000.0010 /21/2011 1 Underwriters at Lloyds A1Q924993 06/20/2011 06/20/2012 09/29/2011 $500,000.0006/30 /2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 05/24/2012 T0.0 SMSA:1222.03.03 WESTFIELD MALL AT SOUTHCENTER Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK IN PREPARATION FOR FUTURE TENANT. SITE INFORMATION: TENANT SPACE 256 TENANT ADDRESS: 911 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -9023 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: I131 SF. TOTAL REVISED SQUARE FEET: 1131 SF - NO ADDITIONAL TENANT SQUARE FEET AS PART OF THIS WORK SEPARATE PERMIT REQUIRED FOR: Mechanical l Electrical ► ° iumbing v: Gas Piping City of Tukwila BUILDING DIVISION OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD (TABLE 100411): OCCUPANCY LOAD FACTOR - RETAIL AREA: 1131 SF / 30 • 38 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 11' IS 49. (TABLE 1015.1) OCCUPANCY LOAD IS 38 THEREFORE ONE EXIT IS REQUIRED. ONE EXIT IS PROVIDED TO THE EXTERIOR THEREFORE OK THERE IS ALSO A DOOR TO THE MALL CONCOURSE. MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED THEREFORE ACCEPTABLE EGRESS WIDTH - 38 (.2) • 8 INCHES - ONE 36" WIDE DOOR IS PROVIDED AT EXTERIOR STOREFRONT THEREFORE OK THERE IS AN ADDITIONAL EXISTING DOOR TO BACK OF HOUSE CORRIDOR THAT IS 3611 WIDE AND A DOOR TO THE MALL CONCOURSE THAT IS 3611 WIDE. TABLE 1016.1 - OCCUPANCY 11 MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 250 - THEREFORE OK SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR ENTRANCE TO THE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WITHIN TENANT SPACE IS LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.4.5.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY I -HOUR FIRE DOOR ASSEMBLY THAT IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.483. SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL PLUMBING REQUIREMENTS: SECTION 29022 - SEPARATE FACILITIES SHALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH MAXIMUM OCCUPANT LOAD IS 50 OR LESS. OCCUPANCY LOAD IS 28 THEREFORE SEPARATE FACILITIES IS NOT REQUIRED. General Notes I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT 15 ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS ,AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUM AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACI4MENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF TI-4E SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. a CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER 10. ALL INTERIOR GLIB IS 1" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE '11 FOR WATER RESISTANT GWB. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E- 2A -I0BC FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" ,4T AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MN. AT FIRE RATES PARTITIONS. I. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 18. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. I. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 21. CONTRACTOR SHALL FURNISH AND INSTALL SPARE CONDUIT AND JBOX AS REQUIRED FOR PRIMARY SIGNAGE LOCATED ON THE EXTERIOR FACADE OF ENTRY DOOR FOR TENANT SIGN THAT IS PROVIDED BY THE TENANT. ALL WIRING AND FINAL CONNECTIONS SHALL BE BY THE TENANT AT TENANTS EXPENSE. CONTRACTOR SHALL ROUTE WIRING THROUGH FRAME OF STOREFRONT AS NEED TO ACCESS SIGN LOCATION. 22. CONTRACTOR SHALL FURNISH AND INSTALL SPARE CONDUIT AND J -5O6 AS REQUIRED FOR TENANT BLADE SIGN LOCATED ,4T EXTERIOR OF NEUTRAL PIER DESIGNATED BY TENANT AND LEASING COORDINATOR ALL (WRING AND FINAL OCNNECTIONS SHALL BE BY TENANT AT TENANTS EXPENSE. Scope of Work SCOPE OF WORK SHALL INCLUDED THE LANDLORD BUILD OUT OF TENANT STOREFRONT TO AN EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER N PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: - SELECTIVE DEMOLITION OF INTERIOR FINISHES, ACOUSTICAL SUSPENDED CEILING AND GRID (INCLUDING BUT NOT LIMITED TO ELECTRICAL AND MECHANICAL FIXTURES), EXTERIOR ALUM. STOREFRONT AND INTERIOR TENANT STOREFRONT AND GRILL, INCLUDING NON - STRUCTURAL PARTITIONS TO ALLOW FOR NEW CONSTRUCTION - CONSTRUCTION OF NEW INTERIOR TENANT MALL STOREFRONTk2 - CONSTRUCTION OF NEW EXTERIOR TENANT MALL STOREFRONT - CONSTRUCTION OF NEUTRAL PIERS AT TENANT MALL STOREFRONT - INSTALLATION OF TYPE X GYPSUM WALL BOARD ON EXISTING WALLS WITHIN TENANT SPACE AND PAINT EXISTING DESIGNATED WALLS TO A LEVEL 4 FINISH T Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET TO.1 GENERAL NOTES A0.0 DEMO FLOOR PLAN AND PHOTO DETAILS A0.1 DEMO RCP AND PHOTO DETAILS A1.0 FLOOR PLAN AND DETAILS A2.0 ELEVATION AND DETAILS A2.1 SECTION AND DETAILS A3.0 REFLECTED CEILING PLAN AND DETAILS Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING Vicinity Map S 154th St. 13rd Star 55 i676 St_, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Man review Approval of co the violation of of;,R:ia''f:KS) FILE COPY V No. ns. nts does not authoits or ordinance. Roc pt Project Directory WEA SOUTHCENTER, LLC 2800 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER: ANDREW CIARROCHI T - 206246.0423 F - 2062448601 FACILITIES MANAGER: CHRISTIAN FALTENBERaER T - 206246.0423 C - 253.611.9435 CFALTENBERGEReWESTFIELD.COM ARCHITECT 511. STEMPER ARCHITECTS, P.L.LC. 4000 Delridge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2111 (206) 624 -2913 FAX waynee metemper.com REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2012 City BUILIN kwila IVISION Site Plan I TENANT SPACE 256 971 SOUTHCENTER mervyivs 2 LEVELS NORDSTROM 3 LEVELS _r L1 JCPenne 3 LEVELS 3 LEVELS Q�z ED MAR 19 2012 PERMIT CENTER EC MAR r TUK UBLlO WsiIle[tf Southcenter 633 Sauthoantar Parkway Tukwla, WA., 98188 -2888 206- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, 15 THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMA110N SHOWN ON THE DRAWING ARE FOR USE ON ME SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERA1SE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624 -2973 TENANT STOREFRONT IMPROVEMENTS ISSUE AT SPACE 256 - MUCHO BURRITO co W F- co Z c) LLI F- < J 0 ISSUE PERMIT SET DATE: MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET ED .'r D, ARKS T0.1 SMSA 1222.03.03 General Notes 1. ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS of MUNICIPAL LOCAL OR FEDERAL AND STATE LAWS AS WELL A5 ANY OTHER GOVERNING REQUIREMENTS, WHETHER OR NOT SPECIFIED ON THE DRAWINGS. 2, WHERE THE CONTRACT NOTES OR DRAWINGS CALL FOR ANY WORK OF A MORE STRINGENT NATURE THAN THAT REQUIRED BY THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE WORK, THE WORK OF THE MOST STRINGENT NATURE CALLED FOR BY THE CONTRACT, CONSTRUCTION NOTES, OR DRAWINGS SHALL BE FURNISHED IN ALL CASES. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LEGALLY REQUIRED APPROVALS AND PERMITS NECESSARY FOR THE EXECUTION AND COMPLETION OF THIS WORK FORWARD COPIES OF EXECUTED PERMITS TO WESTFIELD. 4, ALL WESTFIELD DRAWINGS AND ALL CONSTRUCTION NOTES ARE COMPLEMENTARY, AND WHAT 15 CALLED FOR BY EITHER WILL BE BINDING A5 IF GALLED FOR BY ALL. ANY WORK SHOWN OR REFERRED TO ON ANY ONE SET OF DRAWINGS SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS. 5. THE CONTRACTOR 15 WHOLLY RESPONSIBLE FOR THE COORDINATION AND SCHEDULING OF THE WORK FOR ALL SUBCONTRACTORS, CRAFTSMEN, AND TRADESMEN REQUIRED TO COMPLETE THE JOB. 6. THE CONTRACTOR SHALL NOTIFY WESTFIELD IMMEDIATELY IF HE CANNOT COMPLY WITH ALL REQUIREMENTS CALLED FOR ON THESE DRAWINGS. 1. THE CONTRACTOR SHALL NOTIFY WESTFIELD IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS BETWEEN THE DRAWINGS, THESE NOTES, AND FIELD CONDITIONS, AND REQUEST CLARIFICATION BEFORE COMMENCING ANY WORK a EACH CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE RELATING TO THE WORK OF EACH TRADE. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF TIME DUE TO CONTRACTOR'S FAILURE OR NEGLIGENCE IN COMPLETELY EXAMINING THE JOBSITE. 9, ALL CONTRACTORS SHALL CONTACT WESTFIELD TO DETERMINE THE BUILDING OWNER'S RULES FOR CONSTRUCTION DELIVERIES, CONSTRUCTION TASKS TO BE PERFORMED OUTSIDE REGULAR BUSINESS HOURS, AND ANY OTHER SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THE WORK IF OVERTIME WORK IS REQUIRED BY ANY TRADE, APPROVAL (INCLUDING COST APPROVAL) MUST BE OBTAINED PRIOR TO THE EXECUTION OF ANY WORK. THE GENERAL INTENT IS THAT ALL WORK EXCEPT FOR NOISE - GENERATING CONSTRUCTION SHALL BE PERFORMED ON REGULAR TIME. 10. THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO DEFECTIVE AND /OR ILL -TIMED WORK AS A RESULT OF, BUT NOt LIMITED TO, INFERIOR WORKMANSHIP OR MATERIALS AND /OR IMPROPER SCHEDULING OR DELINQUENT ORDERING, SHALL BE BORNE BY THE PARTY RESPONSIBLE. 11. THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS FROM HIS OWN AND HIS SUBCONTRACTORS' WORK, CARPET AND TELECOM INSTALLATION, Etc., AND PROVIDE FOR ITS REMOVAL FROM THE JOBSITE. 12. THE CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT CONTROL TO PREVENT DIRT OR DUST FROM LEAVING THE JOBSITE. 13. THE CONTRACTOR SHALL PROVIDE PROTECTION DURING SITE WORK, DEMOLITION, AND CONSTRUCTION IN ACCORDANCE WITH IBC CHAPTER 33, THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, OR EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT NE EXPENSE OF THE CONTRACTOR 14. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FOR HIS WORK UNTIL COMPLETION OF CONTRACTED WORK 15. THESE DRAWINGS, NOTES, AND SCHEDULES CONVEY THE DESIGN INTENT. THE HIGHEST POSSIBLE QUALITY OF WORKMANSHIP, MATERIAL, AND EQUIPMENT SHALL BE USED. 16. THE CONTRACTOR SHALL MAINTAIN .4 CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE DURING ALL CONSTRUCTION PHASES FOR THE USE OF ALL TRADES. THE CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF CONSTRUCTION DRAWINGS oR ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK WHEN COMPLETE SETS ARE NOT AVAILABLE TO SUBCONTRACTORS. 11. ALL EXISTING MANUFACTURED ITEMS NOt BEING REMOVED SHALL BE REFURBISHED AS REQUIRED. ANY LOOSE ITEMS TIGHTENED (INCLUDING, BUT NOT LIMITED TO, EXIT SIGNS, DOWNLIGHTS, SPEAKERS, MOULDINGS, ETC.), AND ANY MISSING PARTS REPLACED BY THE CONTRACTOR TO ACHIEVE A COMPLETE INSTALLATION WITH A NEW APPEARANCE. 18. REQUIRED EXITS, WAYS OF APPROACH THERETO, AND WAYS OF TRAVEL FROM THE Exit INTO THE STREET SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS FOR EGRESS IN CASE OF FIRE OR OTHER EMERGENCY. 19. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXIT SIGNS, Exit LIGHTING, FIRE PROTECTION DEVICES AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED. 20. INSURANCE AND BONDING FOR NE PROJECT SHALL BE AS DIRECTED BY AND TO THE SATISFACTION OF WESTFIELD. 21. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION, ELECTRICAL REQUIREMENTS, AND CHARACTERISTICS OF ALL WORK AND /OR EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS PRIOR TO THE START OF RELATED WORK WITH THE MANUFACTURER OR SUPPLIER 22. CONTRACT CLOSE -OUT SHALL OCCUR ONLY AFTER WESTFIELD HAS PREPARED THE CERTIFICATE OF SUBSTANTIAL COMPLETION AND PUNCH LIST, AND PUNCH LIST ITEMS HAVE BEEN CORRECTED. THE CONTRACTOR SHALL SUBMIT MAINTENANCE AND WARRANTY MANUALS, RELEASE OF LIENS, AND RECORD DRAWINGS TO WESTFIELD WIN HIS FINAL APPLICATION FOR PAYMENT. WESTFIELD SHALL PREPARE ANY NECESSARY CHANGE ORDERS REQUIRED TO FINALIZE THE COST OF NE PROJECT BASED ON THE CONTRACTOR'S FINAL SUBMITTALS. 23. MANUFACTURE'S NAME, TRADEMARK, LOGOS, Etc., SHALL NOT BE vISIBLE TO THE PUBLIC. 24. WESTFIELD, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK oR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK THE CONTRACT SUM AND CLAIMS FOR EXTENSION OF TIME SHALL BE ADJUSTED ACCORDINGLY. SUCH WORK SHALL BE OTHERWISE EXECUTED UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT. 25. ALL "EXISTING TO BE RELOCATED ", AND /OR NEW ITEMS INSTALLED BY THE CONTRACTOR IN ADDITION TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION, SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION OF WESTFIELD PRIOR TO BEING TURNED) OVER TO THE OWNER 26. THE CONTRACTOR AGREES TO PAY ALL TRANSPORTATION CHARGES ON ALL MATERIAL AND EQUIPMENT TO THE POINT OF USE AND SHALL BE RESPONSIBLE FOR ALL UNLOADING, CHECKING, AND STORING OF SAME IN CONNECTION WITH THIS CONTRACT. 21. IF THE CONTRACTOR CLAIMS THAT ANY REVISION TO THE DRAWINGS INVOLVES EXTRA COST UNDER THIS CONTRACT, HE 514ALL GIVE WRITTEN NOTICE TO WESTFIELD WITHIN A REASONABLE TIME AFTER RECEIPT OF SUCH INSTRUCTIONS AND IN ANY EVENT, BEFORE PROCEEDING TO EXECUTE THE WORK NE PROCEDURE SHALL BE AS PROVIDED FOR IN THE AGREEMENT UNDER "CHANGES IN THE WORK ". NO SUCH CLAIMS SHALL BE VALID UNLESS SO MADE. UNLESS OTHERWISE AGREED, NO PAYMENT ON SUCH BILLS WILL BE MADE UNTIL FINAL SETTLEMENT. 28. ALL CLAMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING FOR REVIEW BY WESTFIELD AND SHALL INCLUDE A COMPLETE DESCRIPTION OF THE WORK, MATERIALS USED, ROOM NUMBER OF THE AREA OF WORK, AND AUTHORIZATION UNDER WHICH THE WORK 15 BEING PERFORMED. TOTAL COST OF THE WORK, INCLUDING THE CONTRACTOR'S MARK -UP, SHALL BE INCLUDED IN THE SUBMITTAL. 29, THE CONTRACTOR SHALL SUBMIT A DETAILED CONSTRUCTION SCHEDULE TO THE OWNER INDICATING PHASING OF THE WORK FROM START TO FINISH OF THE PROJECT. 30. ALL DIMENSIONS ARE FROM THE FACE OF STUD TO THE FACE OF SW, UNLESS NOTED OTHERWISE. 31. ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENT SHALL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR, UNLESS NOTED OTHERWISE. 32. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD of A YEAR FROM THE ACCEPTANCE OF THE PROJECT BY THE OWNER, UNLESS NOTED OTHERWISE. 33. THE CONTRACTOR SHALL FLASH PATCH FOR CARPET INSTALLATION TO PROVIDE EVEN SURFACE. 34. IN SOUND RATED ROOMS, ALL WALL AND FLOOR PENETRATIONS FOR PIPES, DUCTS AND OUTLETS SHALL BE SEALED WITH AN ACOUSTICAL SEALANT AND CONCEALED OR RECESSED FIXTURES SHALL BE COVERED OR BACKED WITH A SOUND ATTENUATION BLANKET. 35. THE CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING HANGERS, OR OTHER SUPPORT FOR ALL FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS AS REQUIRED. 36. 31. 38. MAXIMUM ROOM OCCUPANT LOAD SIGNS SHALL BE FURNISHED AND INSTALLED AS REQUIRED BY THE BUILDING CODE. DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED IN CENTER OF ROOM OR WITHIN 4" OF ADJOINING PARTITION. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS AIRE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR DEFINITION, WESTFIELD SHALL BE NOTIFIED FOR CLARIFICATION. 39. ALL ITEMS ARE NEW, UNLESS NOTED OTHERWISE. 40. CONTRACTOR SHALL ENSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE REQUIREMENTS. THE MATERIALS SPECIFIED ARE INTENDED TO MEET CODE REQUIREMENTS. ANY DISCREPANCY BETWEEN THE CONSTRUCTION DOCUMENTS AND CODE REQUIREMENTS SHALL 5E BROUGHT TO THE ATTENTION OF WESTFIELD IMMEDIATELY BY THE CONTRACTOR AND PRIOR TO PERFORMANCE OF SPECIFIED WORK 41. DO NOt SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE PETALS GOVERN OVER SMALLER SCALE DETAILS. 42. NO SUBSTITUTIONS OF SPECIFIED MATERIALS SHALL BE PERMITTED WITHOUT FIRST SUBMITTING SPECIFICATIONS, SAMPLES, AND COST IMPACT FOR WESTFIELD'S APPROVAL. 43. AT THE TIME OF BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE WESTFIELD, IN WRITING OF ANY SPECIFIED MATERIALS OR EQUIPMENT THAT IS UNAVAILABLE. 44. THE CONTRACTOR SHALL PROVIDE AND INSTALL ROUGH PLUMBING AND FINAL HOOK -UP FOR ALL SPECIFIED FIXTURES AND APPLIANCES AND SHALL SUPPLY ALL SUCH FIXTURES AND APPLIANCES, UNLESS NOTED OTHERWISE. 45. THE CONTRACTOR SHALL VERIFY REQUIRED LOCATION OF ALL NECESSARY ACCESS PANELS ON PARTITIONS, FLOORS, OR CEILINGS) AND COORDINATE EXACT LOCATIONS WITH WESTFIELD PRIOR TO INSTALLATION. 46. PRIOR TO INSTALLATION OF CARPET AND WINDOW COVERING, THE CONTRACTOR SHALL MAINTAIN NE SPACE IN BROOM CLEAN CONDITION WHETHER OR NOt SUCH INSTALLATION 15 THE CONTRACTOR'S RESPONSIBILITY. 41. THE CONTRACTOR SHALL PROVIDE ALLOWANCE FOR APPLIANCES, UNA. 4a THE CONTRACTOR SHALL LEAVE THE BUILDING IN A LOCKABLE CONDITION DURING THE PERIOD OF THIS WORK WHEN THE CONTRACTOR'S WORKMEN ARE NOT PRESENT AT THE JOBSITE. 49. THE CONTRACTOR SHALL DEACTIVATE ALL UTILITY LINES IN CONTRACT AREA PRIOR TO START OF WORK AS NECESSARY, AFTER SECURING WESTFIELD'S PERMISSION. 50. 5I. 52. THE CONTRACTOR SHALL PATCH, REPAIR, REPLACE, AND /OR REFINISH EXISTING CONSTRUCTION AS NECESSARY TO REFURBISH THE AREA OF WORK THE CONTRACTOR SHALL PROVIDE ALL WORK SHOWN ON THE DRAWINGS UNLESS SPECIFICALLY NOTED AS "NOT IN CONTRACT" (N.LC .). THE BUILDING SHALL COMPLY WITH IBC CHAPTER 11 ACCESSIBILITY REQUIREMENTS AT ENTRANCE, PATH OF TRAVEL TO AREA OF WORK, AND RESTROOMS. 53. ANY REVISIONS OR ADDITIONAL WORK REQUIRED BY THE TENANT, FIELD CONDITIONS, OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND WESTFIELD BEFORE PROCEEDING, REGARDLESS OF COST, TIME, OR MATERIAL INCREASE. 54. BY ENTERING INTO AN AGREEMENT WITH WESTFIELD, THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE JOBSITE, FAMILIARIZED HIMSELF WIN EXISTING CONDITIONS, AND NOTED ANY DESCREFANCIES WITH THE REQUIREMENTS OF NE CONTRACT DOCUMENTS. 55. ANY AND ALL PROPOSED REVISIONS SHALL 8E SUBMITTED IN THE FORM OF A WRITTEN CHANGE ORDER TO BE APPROVED AND AUTHORIZED BY WESTFIELD PRIOR TO START OF PROPOSED WORK 56. BEFORE ACCEPTANCE BY WESTFIELD, THE COMPLETED CONSTRUCTION SHALL SE CLEANED, LABELS REMOVED, AND ALL OTHER TOUCH UP COMPLETED. 51. NE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LIFE SAFETY EQUIPMENT AS REQUIRED BY STATE AND LOCAL BUILDING CODE. 58. FIRE SPRINKLER CONTRACTOR SHALL DESIGN AND PROVIDE CERTIFIED SPRINKLER DRAWINGS FOR WESTFIELD'S APPROVAL. 59. NE CONTRACTOR SHALL HOLD HARMLESS THE BUILDING OWNER WESTFIELD, AND THEIR REPRESENTATIVES OF ANY LEGAL ACTION ARISING AS A RESULT OF THE CONTRACTOR'S WORK 60. CONTRACTOR SHALL PROVIDE THREE (3) SETS OF SHOP DRAWINGS TO WESTFIELD FOR DESIGN APPROVAL AFTER HE HAS REVIEWED THEM FOR CONSTRUCTABILITY, COORDINATION BETWEEN TRADES, AND CONFORMANCE WITH THE CONTRACT DOCUMENTS. 61. THE CONTRACTOR SHALL SUBMIT SAMPLES OF FINISH MATERIALS TO WESTFIELD FOR APPROVAL PRIOR TO INSTALLATION. THE CONTRACTOR SHALL SE WHOLLY LIABLE IF HE MILS TO DO SO, WHETHER FINISHES ARE SPECIFIED CORRECTLY OR INCORRECTLY IN THE CONTRACT DOCUMENTS. 62. DAMEGE TO WORK SHALL BE REPAIRED BY THE TRADE W1-05E WORK IS DAMAGED AND CHARGED TO THE PARTY RESPONSIBLE FOR NE DAMAGE. 63. THESE DOCUMENTS INCORPORATE THE AIA GENERAL CONDITIONS OF TI4E CONTRACT FOR CONSTRUCTION (AIA DOCUMENTS A20I) AND SUPPLEMENTAL CONDITIONS PREPARED BY WESTFIELD, IF ANY, BY REFERENCE. BIDDERS ARE REQUIRED TO BECOME FAMILIAR WITH THESE DOCUMENTS, WHICH CAN BE OBTAINED FROM WESTFIELD. 64. TAPE, BED, AND SAND SMOOCH ALL CORNERS AND JOINTS TO RECEIVE WALL FINISHES. 65. PROVIDE WATER RESISTANT GYPSUM BOARD IN ALL TOILETS AND SHOWER ROOMS. 66. CONTRACTOR TO INFORM WESTFIELD WHEN CHALKLINE LAYOUT OF PARTITIONS IS COMPLETED SO THAT It CAN BE VERIFIED AND ANY REQUIRED CHANGES MADE PRIOR TO CONSTRUCTION. 61. ALL PLUMBING FIXTURES SHALL BE SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. PLUMBING CONTRACTOR SHALL SUPPLY ALL NECESSARY INFORMATION ON REQUIRED CUTOUTS TO MILLWORK CONTRACTOR 68. CONTRACTOR SHALL OBTAIN SEPARATE PERMITS FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK Building Department Notes I. ALL WORK SHALL CONFORM TO THE 2009 INTERNATIONAL BUILDING CODE, 2009 INTERNATIONAL PLUMBING CODE, 2009 INTERNATIONAL MECHANICAL CODE, AND THE 2009 INTERNATIONAL ELECTRICAL CODE, INCLUDING ALL CODES AND REQUIREMENTS FOR LOCAL JURISDICTIONS. 2. NE FACILITIES INCLUDING, BUT NOT LIMITED TO, SANITARY FACILITIES, DRINKING FOUNTAINS, AND ELEVATORS ON ALL FLOORS, MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS. 3. TOILET FACILITIES SHALL BE IDENTIFIED BY SIGNAGE IN COMPLIANCE WIN THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (I8C CHAPTER 11). SUCH SIGNAGE SHALL BE SATIN ALUMINUM WITH BLACK LETTERING AND SYMBOLS. 4. THE PATH OF TRAVEL FROM NE DESIGNATED HANDICAP PARKING SPACES AND THE PUBLIC SIDEWALK PROVIDES A FREE AND UNOBSTRUCTED PASSAGE FOR ACCESS TO AND EGRESS FROM THE AREA OF WORK 5. 6. 1. LIGHT AND CONTROL SWITCHES SHALL BE MOUNTED NOt MORE THAN 4' -0" ABOVE THE FLOOR OR WORKING PLATFORM. DOORS SHALL BE NOT LESS THAN 3' -0" IN WIDTH AND NOT LESS THAN 11 -0" IN HEIGHT. FLOORS OR LANDINGS LOCATED AT A DOORWAY SI-IALL BE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE THRESHOLD, WHICH SHALL HAVE A 1/4" MAXIMUM VERTICAL EDGE AND A CHANGE IN LEVEL NOT CATER THAN 1:2. a A CLEAR AND LEVEL AREA SHALL BE PROVIDED ON EACH SIDE OF EXIT DOORS WITH A LENGTH OF AT LEAST 60" IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48" IN THE OPPOSITE DIRECTION, MEASURED At RIGHT ANGLES THE DOOR IN ITS CLOSED POSITION. 9. 10. 11. 12. ALL HARDWARE SHALL BE OF LEVER TYPE TO COMPLY WITH ACCESSIBILITY REQUIREMENTS. THE BOTTOM 10" OF DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. EXIT DOORS SHALL SWING IN THE DIRECtIO N OF TRAVEL WHEN SERvING AN OCCUPANT LOAD OF MORE THAN 50 (115C CHAPTER 10) EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT NE USE OF A KEY OF ANY SPECIAL KNOWLEDGE oR EFFORT. SPECIAL LOCKING DEv10ES SHALL BE OF AN APPROVED TYPE. EXIT DOORS SHALL EE SELF- CLOSING WITH A DOOR CLOSER SET 50 THAT THE DOOR TAKES AT LEAST 3 SECONDS TO CLOSE FROM AN OPEN POSITION OF 10 DEGREES TO WITHIN 3" OF THE LATCH. Fire Department Notes 15. SUBMIT THREE COMPLETE SETS OF PLANS TO ELECTRICAL DIVISION DEPARTMENT. 16. PROVIDE AUTOMATIC FIRE EXTINGUISHING SYSTEM THROUGHOUT THE FLOOR ALTERATIONS TO THE AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE PREVENTION SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK oN THE FIRE PROTECTION SYSTEM. SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMING DIVISION OF LOCAL BUILDING DEPARTMENT PRIOR TO INSTALLATION (IBC CHAPTER 9). ELEVATOR DOORS SHALL NOt OPEN DIRECTLY INTO ONE -HOUR CORRIDORS (IBC CHAPTER 30). KEY- LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR A PAIR OF DOORS IF THERE 18 A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS ". 20. EXIT DOORS SHALL 8E OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE AN APPROVED TYPE (15C CHAPTER 10). 21. EXIT DOORS 514ALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE, AND ANY HAZARDOUS AREA OR GROUP "E" OCCUPANCY (IBC CHAPTER 10). . 22. EXIT CORRIDORS, EXTERIOR EXIT BALCONIES, AND ,AISLES LEADING TO REQUIRED EXITS SI4ALL HAVE A MINIMUM WIDTH OF 44" (IBC CHAPTER 10). 23. AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC WAY (IBC CHAPTER 10). EXIT PATHS OR WALKWAYS TO A PUBLIC WAY SI-IALL BE CLEARLY DELINEATED BY PAINTED LINES, RAILINGS, BARRIER POSTS, WALKS, OR OTHER APPROVED MEANS. 24. FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE HVAC DUCTS PENETRATE FIRE- RATERD WALLS OR CEILINGS. Partition Notes Construction/ Utility Notes 1, NE CONTRACTOR SHALL SUPPLY AND INSTALL A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 -A OR 2 -4108C WITHIN 15' -o" TRAVEL DISTANCE TO ALL PORTfONS OF THE FLOOR, AND ANY ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT FIELD INSPECTOR. FIRE EXTINGUISHERS SHALL ALSO BE PROVIDED DURING CONSTRUCTION. 2. ALL INTERIOR FINISHES SHALL CONFORM WIN IBC CHAPTER 8. 3. DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS SHALL BE CONCEALED BY DECORATIVE MATERIAL (I8C CHAPTER 8) 4. INTERIOR WALL AND CEILING FINISHES 51-IALL NOt EXCEED AN END POINT FLAME SPREAD OF 200 FOR ALL OFFICES. 5. INTERIOR WALL AND CEILING FINISHES FOR EXIT CONDORS AND STAIRWELLS SHALL NOt EXCEED A FLAME SPREAD CLASSIFICATION OF 15 (CLASS 11). 6. ANY DECORATIONS USED SHALL BE NON - COMBUSTIBLE OR FLAME - RETARDANT MATED IN AN APPROVED MANNER (CURTAIN, DRAPES, SHADES, ETC .). 1, EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY TI4E PREMISES WIRING SYSTEMS. IN THE EVENT OF THIS SYSTEM'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM. EMEGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOTCANDLE AT FLOOR LEVEL (IBC CHAPTER 10). 9. WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIT SO THAT THEY ARE CLEARLY VISIBLE. PROVIDE EXIT SIGNS WITH MINIMUM 6" HIGH BLOCK LETTERS WITH 3/4" STROKE ON A CONTRASTING BACKGROUND. INDICATE THE LOCATION OF EXIT SIGNS ON PLANS (IBC CHAPTER 10). 10. EXIT PATH LIGHTING SHALL BE PROVIDED AT STAIRWAY, HALLWAY, EXIT PASSAGEWAY, AND EGRESS TO A PUBLIC WAY WHENEVER THE BUILDING IS OCCUPIED (IBC CHAPTER 10). 11. EMERGENCY LIGHTING SYSTEM IS REQUIRED AND MUST COMPLY WITH IBC. 12. ALL FIRE ALARM DEVICES SHALL BE LOCATED 48" ABOVE THE FLOOR 13. PROVIDE SMOKE DETECTION IN ALL CORRIDORS AND COMMON AREAS, INCLUDING STAIRWELLS SERVING TWO OR MORE TENANTS (HEALTH AND SAFETY CODE 13113.1). ALTERATIONS TO THE FIRE AND LIFE SAFETY SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM NE FIRE PREVENTION SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE AND LIFE SAFETY SYSTEM. 14. PROVIDE AN APPROVED FIRE ALAN SYSTEM WITH A DESCRIPTION OF SEQUENCE OF OPERATION AND LISTED STATE FIRE MARSHALL APPROVED EQUIPMENT. I. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PARTITIONS INDICATED ON THE DRAWINGS. 2. 3. 4. 5. 6. PARTITION DIMENSIONS ARE STUD FACE TO STUD FACE UN.O. CENTER LINE OF PARTITION SHALL ALIGN WITH CENTER LINE OF MULLION WHERE OCCURS, UN.O. PARTITIONS SWAIN ALIGNED WITH EXISTING BASE BUILDING ELEMENTS SHALL BE INSTALLED FLUSH AND SMOOTH WITH BASE BUILDING ELEMENTS. THE CONTRACTOR SHALL USE CORNER BEADS AT ALL EXPOSED CORNERS AND EXPOSED ENDS IN PLASTER AND DRYWALL PARTITIONS. ALL PARTITIONS SHALL BE ANCHORED PER MANUFACTURER'S SPECIFICATIONS AND AS REQUIRED BY APPLICABLE BUILDING CODES. THE CONTRACTOR SHALL SUPPLY ALL RETURN AIR OPENINGS IN SLAB TO SLAB PARTITIONS ABOVE CEILINGS AS REQUIRED BY ENGINEERING DRAWINGS. ALL OPENINGS IN DEMISING AND SOUND- ATTENUATED PARTITIONS SHALL HAVE SOUND BOOTS AND ALL OPENINGS IN FIRE -RATED PARTITIONS SHALL HAVE FIRE DAMPERS AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL COORDINATE WITH ENGINEERING DRAWINGS AND INFORM WESTFIELD OF DISCREPANCIES PRIOR TO BIDDING. 1. THE CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING IN PARTITIONS FOR ALL DUCT WORK RETURN AIR OPENINGS AND GRILLS ABOVE AND BELOW CEILINGS SHALL BE COORDINATED WITH MECHANICAL ENGINEERING DRAWINGS AND MECHANICAL CONTRACTOR'S SHOP DRAWINGS. ALL OPENINGS SHALL BE PROPERLY SEALED FOR SOUNDPROOFING AND AGAINST VIBRATION. a THE CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING INSTALLATIONS PER APPLICABLE BUILDING CODES. CONTRACTOR SHALL COORDINATE TYPE AND LOCATION OF ACCESS PANELS WITH WESTFIELD PRIOR TO INSTALLATION. 9. WESTFIELD SI4ALL HAVE THE RIGHT TO REVIEW AND APPROVE CHALK LINES PRIOR to INSTALLATION OF TRACKS. WESTFIELD SHALL BE NOTIFIED OF ANY DEVIATION FROM DIMENSIONS OR CLEARANCES ON PLANS REQUIRED DUE TO FIELD CONDITIONS. 10. NE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING ROUGH -INS, FIXTURES, AND ACCESSORIES INDICATED IN THE DRAWINGS. II. THE PLUMBING CONTRACTOR SHALL SUBMIT CUTS OF ALL NEW FIXTURES, FITTINGS, AND ACCESSORIES TO WESTFIELD FOR REVIEW. 12. NE PLUMBING CONTRACTOR SHALL COORDINATE AND INSTALL HIS WORK IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 13. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL VALVES AS INDICATED IN THE DRAWINGS AND /OR AS REQUIRED FOR THE PROPER CONTROL OF THE PIPING AND APPARATUS INSTALLED AS PART OF THIS PROJECT 50 THAT ANY FIXTURE, LINE, OR APPARATUS MAY BE CUT OFF AND REPAIRED WITHOUT INTERFERENCE OR INTERRUPTION OF SERVICE TO THE REMAINDER OF THE BUILDING. 14. BEFORE COVERED UP OR BUILT -IN, ALL PIPING SI4ALL BE TESTED AND INSPECTED AS REQUIRED BY THE AUTHORITIES HAYING JURISDICTION. 1. CONTRACTOR SHALL FURNISH AND INSTALL 119 NATURAL GAS SERVICE TO THE THE REAR OF THE TENANT SPACE. COORDINATE INSTALLATION WIN WESTFIELD AND FUTURE TENANT. 2. CONTRACTOR SHALL FURNISH AND INSTALL ROOF TOP UNIT AT EXISTING RTU PER DESIGN BUILD MECHANICAL CONTRACTOR CONTRACTOR SHALL VERIFY SIZE AND WEIGHT OF EXISTING UNIT AND CONDITION OF EXISTING ROOF CURB. CONTRACTOR SHALL FURNISH AND INSTALL REQUIRED STRUCTURAL SUPPORT PER LOCAL JURISDICTIONS FOR SUPPORT OF NEW RTU, IF WEIGHT AND SIZE ARE GREATER THAN EXISTING UNIT. ALL ROOF PENETRATIONS 514ALL BE COORDINATED WITH WESTFIELD. NEW RTU HVAC SHALL BE (I) FIVE TON UNIT AND BE IN PROPER WORKING ORDER WITH CERTIFICATE, VERIFYING THE SAME. 3. CONTRACTOR SHALL FURNISH AND INSTALL ONE (I) TWO -STAGE HEAT /COOL THERMOSTAT FOR HEATING AND COOLING OF TENANT'S DEMISED AREA IN ACCORDANCE TO TENANT'S SPECIFICATIONS. 4. CONTRACTOR SHALL FURNISH AND INSTALL ELECTRICAL SERVICE FROM MALL METER ROOM TO TENANT DEMISED AREA. 5. CONTRACTOR SHALL DEMOLISH EXISTING ELECTRICAL PANEL AND FURNISH AND INSTALL 200 AMP 120 / 208 SERVICE 3 - P1-1A5E SERVICE; '4 WIRE, 42 PANEL BOX AT LOCATION TO BE DETERMINED BY TENANT. 6. CONTRACTOR SHALL FURNISH AND INSTALL TELEPHONE CONDUIT FROM MALL TELECOM ROOM TO REAR OF TENANT DEMISED SPACE. 1. CONTRACTOR SHALL ROUGH IN SEWER LINE STUBBED UP ABOVE CONCRETE FLOOR - SIZED ADEQUATELY TO ACCOMMODATE WASTE LINES PER TENANT SPECIFICATIONS. CONTRACTOR SHALL SAWCUT, TRENCH, BACKFILL, PATCH CONCRETE FLOOR TO LOCATE REQUIRED STUB UP AT LOCATION DETERI" LINED BY TENANT. 8. CONTRACTOR SI4ALL FURNISH AND INSTALL WATER SERVICE TO THE REAR OF TENANT DEMISED SPACE. 9. CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) FLOOR DRAINS AT LOCATION TO BE DETERMINED BY TENANT. CONNECT TO WASTE LINES. CONTRACTOR SHALL SAWCUT, TRENCH, BACKFILL, PATCH CONCRETE FLOOR TO LOCATE REQUIRED STUB UP AT LOCATION DETERMINED BY TENANT. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2012 City of Tukwila BUILDING DIVISION D KEY - LEGEND - EXISTING DOOR - NEW DOOR - EXISTING DOOR TO BE DEMOLISHED AND /OR SALVAGED FOR REUSE • - - EGRESS PATH - STORAGE SCREEN WALL - EXISTING WALL NEW WALL - EXISTING WALL TO BE DEMOLISHED - (E) LIGHT FIXTURE TO BE DEMOLISHED - LEASE LINE S - LIGHT SWITCH db - ELECTRICAL OUTLET - DATA OUTLET - EMERGENCY EXIT SIGN EXIT - EGRESS EXIT MAR 19 2012 ERMIT CENTER PE Wesdle[c[ South cen ter 633 Sauthoenter Parkway lbkwa, WA., 98168-2868 206- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, 15 THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME, ALL OESGN AND OTHER INFORMAI1ON SHOWN ON THE ORAMNG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT ■ S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: MPROVEMENTS TENANT STOREFRONT 0 ca 0 U N LU U 0 i- < PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ GENERAL NOTES A I .0 SMSA:1222.03.03 XTERIOR 51' -0" (E) SLIDING DOOR TO BE DEMOLISHED IN ITS ENTIRETY (E) MALL CONCOURSE TYP. 33' -S 1/2" DEMOLITION FLOOR PLAN 1 /4" = 1' -0" OUTLINE OF (E) STOREFRONT TO BE DEMOLISHED IN; ITS ,.:; EXTERIOR ELEVATION N.T.S. ADJACENT TENANT SPACE - NO WORK THIS AREA -\\ INTERIOR ELEVATION N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2012 City of Tukwila BUILDING DIVISION PHOTO DETAIL N.T.S. PHOTO DETAIL N.T.S. PHOTO DETAIL N.T.S. PHOTO DETAIL N.T.S. DEMOLITION GENERAL AL NOTES: I. ALL REASONABLE EFFORT WAS BEEN MADE BY THE DESIGN TEAM TO REPRESENT EXISTING CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF EXISTING ITEMS, NCLUDING BUT NOT LIMITED TO, FLOORING, CEILING, WALL ASSEMBLY, WALL FINISHES, ETC. IN EFFORT TO PREPARE SPACE FOR NEW CONSTRUCTION. 2. ALL ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEM WITHIN THE AREA OF DEMOLITION SHALL BE DEMOLISHED 114 THEIR ENTIRETY AND CAPPED AT THEIR RESPECTIVE POINT OF ORIGIN. O EMO FLOOR PLAN KAY NOTES: 0 0 0 05 OUTLINE OF AREA DESIGNATED TO BE DEMOLISHED BY CONTRACTOR IN PREPARATION AND ACCESS FOR DEMOLITION OF WALL ASSEMBLY AND CONSTRUCTION OF NEW TENANT DEMISING WALL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEMOLISH AND REMOVE ANY OBSTRUCTIONS THAT PREVENT DEMOLITION AND CONSTRUCTION ACTIVITY. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE DEMOLITION OF CEILING TILE AND GRID, LIGHTING, MECHANICAL, FIRE ALARM, AND SPRINKLER SYSTEMS AS REQUIRED FOR DEMOLITION AND CONSTRUCTION OF DESIGNATED WALL ASSEMBLY. (E) FLOOR FINISHES TO BE DEMOLISHED IN THEIR ENTIRETY, INCLUDING BUT NOT LIMITED TO, TILE, WOOD FLOOR, VCT, CARPET, ADHESIVES, GROUT, ETC. (E) METAL STUD FRAMING AND GLOB WALL ASSEMBLY TO BE DEMOLISHED IN ITS ENTIRETY, FROM SLAB TO STRUCTURE. DEMOLITION OF WALL ASSEMBLY SHALL INCLUDE, BUT NOT BE LIMITED TO, STUD BOTTOM AND TOP TRACK, METAL STUD FRAMING, GWB, WOOD TRIM, WALL FIXTURES, ELECTRICAL, DATA, AND MECHANICAL FIXTURES /SERVICES. (E) DOOR AND FRAME TO BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, DOOR, FRAME, HARDWARE, ETC. (E) STOREFRONT TO BE DEMOLISHED IN ITS ENTIRETY TO ALLOW FOR CONSTRUCTION OF STOREFRONT AS INDICATED ON PLANS. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, GLAZING, WOOD TRIM, SIGNS, RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, AND CEILING - MOUNTED FIXTURES, AND LIGHTING. (E) OVERHEAD COILING GRILLE TO 8E DEMOLIGI -TED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, FRAME, MOTOR, POWER, GRILLE, ETC. (E) TENANT DEMISING WALL TO REMAIN. PAINT TO LEVEL 4 FINISH. (E) RESTROOM TO BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, METAL STUD FRAMING/ GWB WALL ASSEMBLY, WALL FINISHES, PLUMBING FIXTURES, CEILING, ELECTRICAL FIXTURE, POWER, SWITCHES, CONDUITS, WALL - MOUNTED FIXTURES, ETC. CONTRACTOR SHALL CAP ALL UTILITIES AT POINT OF ORIGN TYPICAL, POWER MECHANICAL, PLUMBING, SPRINKLER, AND FIRE ALARM. 09 (E) SINK TO BE DEMOLISHED IN ITS ENTIRETY. TERMINATE ALL PLUMBING, SUPPLY, AND WASTE LINES AT POINT OF ORIGIN. 10 (E) WATER CLOSET TO BE DEMOLISHED IN ITS ENTIRETY. TERMINATE ALL PLUMBING, SUPPLY, AND WASTE LINES AT POINT OF ORIGIN. 11 (E) ELECTRICAL PANEL TO BE DEMOLISHED IN ITS ENTIRETY. 12 (E) WATER HEATER TO BE DEMOLISHED IN ITS ENTIRETY. 13 (E) CASEWORK TO BE DEMOLISHED IN ITS ENTIRETY. 1� (E) TILE AT MALL CONCOURSE TO BE DEMOLISHED. r SHADED AREA SHALL REPRESENT THAT AREA DESIGNATED TO BE DEMOLISHED IN ORDER FOR NEW CONSTRUCTION AND EXPANSION OF VACANT TENANT SPACE. DEMOLITION SHALL INCLUDE BUT NOT BE LIMITED TO WALLS, CASEWORK, COLUMN COVERS, FIXTURES FLOORING, BASE, AND ALL FINISHES ASSOCIATED WITHIN THE AREA OF DEMOLITION IN PREPARATION OF NEW CONSTRUCTION. b io8? RECEIVED MAR 19 2012 PERMIT CENTER 9;&iiew Southcenter 633 Southcenter Parkway Tukwila. WA.. 98188 -2888 208 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS ME REPRODUCRON CARRIES THE ARCHITECT'S NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON ME DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT DE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (200) 624 -2973 MPER INGTON Ct W I-- z w U Z H 0 (1) J J W CD W ISSUE ISSUE DATE: CO z w 2 w 0 0 z O w 0 co z z w 0 m 0 Z U rl CV w U 0 U7 I- < PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ DEMO FLOOR PLAN AND PHOTO DETAILS A0.1 SMSA:1222.03.03 SI T EXTE IOR —\\ -h----- L - - - =_ 1 -1 -- i-- - - - - -; - I I L-- ----J- \_(E) MALL CONCOURSE - DEMOLITION FLOOR PLAN 1/4" = 1' -O" PHOTO DETAIL N.T.S. ADJACENT1 TENANT SPACE - NO WOW THIS AREA —N\ PHOTO DETAIL N.T.S. PHOTO DETAIL N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED APR 05 2012 City of Tukwila BUILDING DIVISION DEMOLITION GENERAL NOTES: 1 ALL REASONABLE EFFORT HAS BEEN MADE BY THE DESIGN TEAM TO REPRESENT EXISTING CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF EXISTING ITEMS, INCLUDING BUT NOT LIMITED TO, FLOORING, CEILING, WALL ASSEMBLY, WALL FINISHES, ETC. IN EFFORT TO PREPARE SPACE FOR NEW CONSTRUCTION. 2. ALL ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEM WITHIN THE AREA OF DEMOLITION SHALL BE DEMOLISHED IN THEIR ENTIRETY AND CAPPED AT THEIR RESPECTIVE POINT OF ORIGIN. DEMO RCP KEY NOTES: , (E) CEILING TILE AND GRID TO BE DEMOLISHED IN ITS ENTIRETY, TO ALLOW FOR DEMOLITION AND CONSTRUCTION OF WALL ASSEMBLIES AS INDICATED ON PLANS. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, TRACK LIGHTING, RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, CEILING - MOUNTED FIXTURES, LIGHTING, ETC. ALL UTILITIES SHALL BE CAPPED AT POINT OF ORIGIN. lag (E) GWB SOFFIT AND FRAMING TO BE DEMOLISHED IN ITS ENTIRETY, TO ALLOW FOR DEMOLITION AND CONSTRUCTION OF WALL ASSEMBLIES AS INDICATED ON PLANS. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, WOO TRIM, CEILING- MOUNTED FIXTURES, AND LIGHTING. a>. (E) STOREFRONT BULKHEAD 4 OVERHEAD COILING GRILLE TO BE DEMOLISHED IN THEIR ENTIRETY TO ALLOW FOR DEMOLITION AND CONSTRUCTION OF WALL ASSEMBLIES AS INDICATED ON PLANS. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, GLAZING, WOOD TRIM, SIGNS, RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, CEILING- MOUNTED FIXTURES, LIGHTING, ETC. SHADED AREA SHALL REPRESENT THAT AREA DESIGNATED TO BE DEMOLISHED IN ORDER FOR NEW CONSTRUCTION AND EXPANSION OF VACANT TENANT SPACE. DEMOLITION SHALL INCLUDE, BUT NOT 8E LIMITED TO TRACK LIGHTING, RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, CEILING - MOUNTED FIXTURES, LIGHTING, ETC., ASSOCIATED WITHIN THE AREA OF DEMOLITION IN PRE ARATION OF NEW CONSTRUCTION. 61)-.0 ect RECEIVED MAR 19 2012 PERMIT CENTER WslIle[Lf South center 833 Sauthcenter Parkway Tukwila, WA.. 9 81 88 -2888 208 - 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY Or THE ARCHITECT AND MAY NOT BE REPRODUCED YATHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INFORMATION SHORN ON WE DRAWNC ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 624 -2973 WESTFIELD MALL AT SOUTHCENTER ISSUE ISSUE DATE: �co W - Z rn W I< z < 0 J PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ DEMO RCP AND PHOTO DETAILS A1.0 SMSA 1222.03.0 (E) CURB (E) BRICK COLUMN TO REMAIN (E) BRICK COLUMN TO REMAIN (E) BRICK COLUMN TO REMAIN 52' -4" (E) SIDEWALK TO REMAIN 36' -3" (E) BACK OF HOUSE CORRIDOR TO REMAIN TENANT LEASE LINE i" ALUMINUM REVEAL BACKER ROD AND CAULK - TYPICAL LEASE LINE (E) VACANT TENANT SPACE - NO WORK THIS AREA 20-3" VACANT TENANT SPAC 100 4' -0" ALUMINUM STOREFRONT FRAMING WITH INSULATED GLAZING TYP. ALUMINUM STOREFRONT FRAMING WITH X" THICK GLAZING a(aG rlivctic- ■( vC LEASE L INE 35' -10 15/16" r■ LEASE LINE (E) ALUM. STOREFRONT AT MALL CONCOURSE 1 4' -1 1/4" LEASE LINE `(E) MALL CONCOURSE ± 2' -6" 56' -1 15/16" FLOOR PLAN (E) WALL ASSEMBLY RE: WALL TYPE 1/4" = 1' -0" (E) MALL STOREFRONT TO REMAIN 4 1/2" X 4 1/2" CORNER ALUM. STOREFRONt FRAMING TENANT LEASE LINE J ALUMINUM STOREFRONT AND GLAZING SYSTEM - TYPICAL NEUTRAL PIER DETAIL 1 1/2" = 1' -0" (E) VACANT TENANT SPACE - NO WORK THIS AREA 4 1/2" X 4 1/2" CORNER ALUM. STOREFRONT FRAMING BACKER ROD AND CAULK LEASE X" ALUMINUM REVEAL - X" THICK TEMPERED GLAZING - TYP. (E) WALL ASSEMBLY RE: WALL TYPE 2' -6" ADJACENT TENANT 7 STOREFRONT TO REMAIN NEUTRAL PIER DETAIL 1 1 /2" = ALUM. STOREFRONT FRAMING WITH X" THICK GLAZING - L INE UP STOREFRONT WITH FACE OF ADJACENT TENANT TO THE SOUTH REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2012 City of Tukwila BUILDING DIVISION UJ,4LL TYPES WALL TYPE CNERAL NOTES: EXISTING WALL TYPE - (E) 5/8" TYPE X GM - (E) 6" (16 GA) METAL STUD FRAMING - (E) EXTERIOR SHEATHING - (E) BUILDING PAPER - (E) BRICK VENEER 2 EXISTING WALL TYPE (1 -14R RATED) UL DESIGN U -465 - (E) 5/8" TYPE X GLOB - (E) METAL STUD FRAMING - (E) 5/8" TYPE X GWB AT TENANT SPACE CONTRACTOR 51-1ALL VERIFY THE STATUS OF EXISTING WALL ASSEMBLY TO MEET MEET 1-HR RATED ASSEMBLY REQUIREMENT. I. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO, METAL STUD WIDTH AND THICKNESS, HEIGHT OF STUD FRAMING, CONDITION OF EXISTING GWB. 2. CONTRACTOR SHALL PREP AND PRIME ALL VACANT TENANT SPACE GM TO LEVEL 4 FINISH. 3. CONTRACTOR SHALL PREP AND PAINT ALL MALL CONCOURSE- RELATED AREAS (NEUTRAL PIERS, BULKHEAD, ETC.) TO LEVEL 4 FINISH. COLOR TO BE DETERMINED BY WESTFIELD. 4. CONTRACTOR SHALL MAINTAIN RATING OF ALL 1-HOUR RATED ASSEMBLIES (EXISTING AND NEW) WITHIN AREA OF WORK of; viii 1 ;\ FLOOR PLAN GENERAL NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL COORDINATE WITH LANDLORD REGARDING EXISTING CONDITIONS. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN - LEAVING MIN. 6" GAP ,4T TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL/MECHANICAL ARE SHOUIIN FOR REFERENCE ONLY. DATA, ELECTRICAL, AND MECHANICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ANY WOOD COMPONENTS USED SHALL BE FIRE - RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603 4 2604) 6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA 8. CONTRACTOR SHALL PRIME ALL NEWLY CONSTRUCTED WALLS, NEUTRAL PIERS, SOFFITS, AND BULKHEADS TO LEVEL 4 FINISH. NEUTRAL PIER AND MALL CONCOURSE AREAS TO BE PAINTED TO LEVEL 4 FINISH. 9. AREAS DESIGNATED AS "EXISTING - NO WORK" SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE SET FORTH BY LOCAL AND NATIONAL CODES AND JURISDICTIONS HAVING AUTHORITY. 10. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED AT FINISH FLOOR LEVEL FOR ALL SERVICES AND UTILITIES WITHIN THE FLOOR SLAB. CONTRACTOR SHALL PATCH CONCRETE SLAB AND PROVIDE SMOOTH AND LEVEL FLOOR SLAB READY TO RECEIVE FLOOR FINISH BY TENANT. 11. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS POINT OF ORIGIN. 12. CONTRACTOR SHALL COORDINATE AND CONFIRM DOOR CLEARANCES AT EACH DOOR AND THRESHOLD, INCLUDING COORDINATION OF FUTURE TENANT FLOOR FINISHES. 13. RECEPTACLE AND COVERPLATES IN STOREFRONT SOFFIT 51-1ALL BE FLUSH- MOUNTED PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. RE: ELECTRICAL 14. MOUNT SALES AREA DUPLEX RECEPTACLES AND COVERPLATES AT 18" AFF. WHERE RECEPTACLES ARE LOCATED BEHIND WALL PANELS, MOUNT HORIZONTALLY AT 8" AFF. CIRCUIT TO PANEL AS INDICATED ON ELECTRICAL. RE: ELECTRICAL. 15. RECEPTACLES FOR CCTV SHALL BE LOCATED AT 6' -0" AFF. 16. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL DUCT - MOUNTED SMOKE DETECTORS. THE DETECTOR SHALL BE INSTALLED IN THE DUCTWORK BY MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR WITH HVAC UNIT AND MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. HVAC UNIT SHALL SHUT DOWN UPON ACTIVATION OF SMOKE DETECTOR COORDINATE WITH MECHANICAL CONTRACTOR AND LANDLORD TO PREVENT ANY CONFLICTS IN FIELD. RE: MECHANICAL AND ELECTRICAL 11. CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS FOR I AC CONNECTION SCHEDULE AND WIRING REQUIREMENTS. O FLOOR PLAN KEY NOTES: CONTRACTOR SHALL DEMO (E) FLOORING AND CLEAN EXISTING SLAB IN PREPARATION FOR FLOORING TO BE INSTALLED BY TENANT. SLAB SHALL BE FREE OF ADHESIVE, RESIDUE, ASSOCIATED ANCHORS, ETC. OEXISTING WALL TO REMAIN. CONTRACTOR SHALL PRIME AND PREP EXISTING GWB TO LEVEL 4 FINISH. FINAL PAINT COATING SHALL BE BY FUTURE TENANT. NEUTRAL PIER CONSTRUCTION PER WALL TYPE AND DETAILS. CONTRACTOR SHALL PREP AND PAINT GWB ALONG MALL CONCOURSE TO MATCH ADJACENT MALL CONCOURSE IN COLOR, TEXTURE, AND FINISH. RECEIVED MAR 19 2012 PERMIT CENTER WesiIle[c[ Southcenter 833 Southcenter Parkway Tukwila. WA.. 98188 -2888 206 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME, ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 624 -2973 z w U jo f O w C. :E z rn U < Q � J D < 9J Q CSI C%) w z �-- � CO 111 If TEN) ISSUE ISSUE DATE: PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN AND DETAILS A2.0 SMSA:1222.03.03 TTOM OF (E) BULKHEAD 13' -10" A" BLACK ALUM. REVEAL LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE dpTOP OF STOREFRONT 10' -2" PROPOSED LOCATION OF TENANT BLADE SIGN. PROVIDE SPARE CONDUIT s J -BOX. COORDINATE WITH TENANT. EXISTING MALL CONCOURSE BULKHEAD - FIELD VERIFY HEIGHT LOCATION OF STOREFRONT SIGN. REVERSE CHANNEL LETTERS - PROVIDE SPARE CONDUIT $ J -BOX. COORDINATE WITH TENANT. —1 LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE X" BLACK ALUMINUM REVEAL (E) NEUTRAL PIER TO REMAIN SQUARE GLAZING CLIPS TYPICAL (2) AT EACH JOINT EXISTING MALL ENTRY TO REMAIN XX" BLACK ALUM. REVEAL FINISH FLOOR 0' -0" (E) STONE FINISH TO REMAIN (E) STOREFRONT AT MALL CONCOURSE TO REMAIN ALUMINUM STOREFRONT AND 119 THICK GLAZING TYPICAL. )5" BLACK ALUMINUM REVEAL ALUMINUM STOREFRONT AND ti " THICK GLAZING TYPICAL. EAST ELEVATION (INTERIOR) 1/2" = 1' -0" TILE BACKER BOARD AT STONE VENEER - TYP. 6" METAL STUD FRAMING - CONTINUE TO SOFFIT ABOVE THIN LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE INT. HEAD DETAIL %' GWB - TYPICAL 6" METAL STUD HEADER - TYPICAL BACKER ROD AND CAULK - TYPICAL EACH SIDE ALUMINUM STOREFRONT FRAMING - TYPICAL GLAZING ADAPTER - TYPICAL Xi" THICK TEMPERED GLAZING x" THICK TEMPERED GLAZING - TYPICAL SEALANT AT BASE STOREFRONT (E) MALL CONCOURSE TILE TERMINATE AT FACE OF STOREFRONT ALUMINUM STOREFRONT FRAMING AT SILL BACKER ROD AND CAULK AT SILL - FINISH FLOOR TENANT FLOOR FINISH BY OTHERS NOTE: DEMO AND INSTALL MALL CONCOURSE TILE AS REQUIRED FOR INSTALLATION OF NEIU STOREFRONT INT. SILL DETAIL J GLASS ENTRY DOOR WITH 1/5" THICK GLAZING TYPICAL. TILE BACKER BOARD ,AT STONE VENEER - TYP. 6" METAL STUD FRAMING - CONTINUE TO SOFFIT ABOVE LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE PAINT GM BLACK TO LEVEL 4 FINISH INT. DOOR HEAD DETAIL %" GWB - TYPICAL 6" METAL STUD HEADER - TYPICAL ALUMINUM FRAME DOUBLE ACTING DOOR STILE AND RECESSED CLOSER DOOR STILE AT HEAD )5" THICK TEMPERED GLAZING 3" = 1' -0" NOTE: CONTRACTOR SHALL PROVIDE REQUIRED CLEARANCES AT THRESHOLD FOR FLOOR FINISHES (INCLUDING TENANT FINISHES) "r` a ="uuu"UDU"ull NIIIIIIIIIUUIIIIIIIIIIIIIIIII iUIIIIIIUIIIIIIU"URU6tt )Y" THICK TEMPERED GLAZING DOOR STILE AT FLOOR TRANSITION OF FLOOR FINISH AT CENTER LINE OF DOOR FINISH FLOOR PER TENANT MALL CONCOURSE TILE, TYPICAL DEMO TILE AS REQUIRED FOR INSTALLATION OF NEW STOREFRONT INT. THRESHHOLD DETAIL 3" = 1' -0" EXISTING BRICK FACADE TO REMAIN \\— EXISTING MALL ENTRY TO REMAIN )5" GAP - MAXIMUM ALUMINUM STOREFRONT AND INSULATED GLAZING TYPICAL. T- I Ll1 I �/ =1 Z (L EQ. if 1L LI / 1 I_ L.� /// 15' -3" ROUGH OPENING (F.V.) EQ / EQ. ALUMINUM STOREFRONT AND INSULATED GLAZING TYPICAL. NORTH ELEVATION (EXTERIOR) 1 /2" = 1' -0" EQ / = a/% EQ. EQ. // B.o. EXIST. SOFFIT 1 1 --T 1 T— 10' -0" 1 10 42.1 1/2" THICK TEMPERED GLAZING - TYPICAL 2" SQUARE GLAZING CL MIN. (2) AT EACH JOINT INT. BUTT JOINT DETAIL 3" = 11 -0" ALUMINUM FRAME BELOW X" GAP - MAXIMUM INT. CORNER DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED APR 05 2012 City of Tukwila BUILDING DIVISION 1/2" THICK TEMPERED GLAZING - TYPICAL 2" L -SHAPE GLAZING CLIPS, MIN. (2) AT EACH JOINT 3" = 1l -0" GLAZING ADAPTER - TYPICAL 1/2" TI-IK TEMPERED GLASS ENTRY DOOR - TYPICAL )¢" THICK TEMPERED GLAZING - TYPICAL 2" X 4 1/2" COMER ALUMINUM STOREFRONT FRAMING - TYPICAL ALUMINUM STOREFRONT SILL BELOW INT. DOOR JAMB DETAIL 3" = 1' -0" (E) WALL ASSEMBLY TO REMAIN A2.1 _ryas " [-Val EXISTING BRICK FACADE TO REMAIN —\ FINISH FLOOR 010" 3' 0" X 9' -10" ALUMINUM ENTRY DOOR WITH INSULATED GLAZING MEDIUM STILE BACKER ROD AND CAULK 4 I/2" X 4 1/2" CORNER ALUM. STOREFRONT FRAMING ALUM. STOREFRONT SILL BELOW INT. JAMB DETAIL (E) STONE FINISH TO REMAIN BLACK X" LAL ALUMINUM GLAZING ADAPTER - TYPICAL 1/2" THICK TEMPERED GLAZING - TYPICAL 3" = 1l -0" 2" X 4 I/2" ALUM. STOREFRONT FRAMING AT DOOR GLASS DOOR WITH )i" THICK TEMPERED GLAZING 1/2" THICK TEMPERED GLAZING - TYPICAL 4 1/2" X 4 1/2" CORNER ALUM. STOREFRONT FRAMING GLAZING ADAPTER - TYPICAL INT. JAMB /CORNER DETAIL 3" = 1' -0" D11 089 RECEIVED MAR 19 2012 PERMIT CENTER igsifleki Southcenter 833 Southcenter Parkway Tukwila, WA., 98188 -2888 208 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERLY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ ELEVATIONS AND DETAILS A2.1 SMSA:1222.03.0 (E) METAL STUD FRAMING AND HEADER TO REMAIN SEALANT EACH SIDE - TYPICAL SEALANT EACH SIDE TYPICAL EXIST. CONCRETE SLAB ON GRADE FLOOR FINISH BY TENANT EXTERIOR WALL SECTION 1" = 1' -0" EXISTING METAL STUD SOFFIT FRAMING TO REMAIN - SHORE AS REQUIRED FOR DEMOLITON OF EXISTING BRICK FACADE B.O. EXIST. SOFFIT 10' -0" AFF ALUMINUM STOREFRONT FRAMING AND INSULATED GLAZING - TYPICAL 6" ALUMINUM CURTAIN WALL FRAME ALUMINUM HORIZONTAL STOREFRONT FRAMING - TYPICAL EXISTING BRICK FACADE BEYOND 1" INSULATE GLAZING IN ALUMINUM STOREFRONT ALUMINUM HORIZONTAL STOREFRONT FRAMING - TYPICAL ALUMINUM STOREFRONT SILL SET IN SEALNT FIRST LEVEL FF 01_09 EXISTING CONCRETE SIDEWALK TO REMAIN (E) GWB PATCH AND REPAIR TO LEVEL 4 FINISH BACKER ROD AND SEALANT TYPICAL EACH SIDE ALUMINUM STOREFRONT FRAMING AT HEAD ALUMINUM ENTRY DOOR EXISTING METAL STUD SOFFIT FRAMING TO REMAIN 0 INSULATED GLAZING - TYPICAL EXT. DOOR HEAD DETAIL 3" = 1' -0" (E) GWB PATCH AND REPAIR TO LEVEL 4 FINISH BACKER ROD AND SEALANT TYPICAL EACH SIDE THRESHOLD BELOW EXT. DOOR JAMB DETAIL 3" = 1' -0" ALUMINUM VERTICAL MULLION EXT. DOOR JAMB DETAIL 3" = 1' -0" 1" INSULATED GLAZING, TYP. WIDE STILE ALUMINUM ENTRY DOOR (E) EXTERIOR SIDEWALK L (E) WALL ASSEMBLY TO REMAIN ALUMINUM STOREFRONT FRAMING AT JAMB CONTINUOUS HINGE TYPICAL ALUMINUM ENTRY DOOR INSULATED GLAZING - TYPICAL I" INSULATED GLAZING, TYP. -DTI ..4111M n1 THERMALLY BROKN ALUMINUM THRESHOLD SET IN SEALANT EXIST. CONCRETE SIDEWALK EXIST. CONCRETE SLAB ON GRADE EXT. DOOR THRESHOLD DETAIL 3" = 1' -0" B.O. EXIST. SOFFIT 10-0" AFF EXISTING SOFFIT TO REMAIN (E) GWB PATCH AND REPAIR TO LEVEL 4 FINISH BACKER ROD AND SEALANT TYPICAL EACH SIDE EXISTING METAL STUD SOFFIT FRAMING TO REMAIN ALUMINUM STOREFRONT FRAMING AT HEAD INSULATED GLAZING - TYPICAL EXT. HEAD DETAIL 3" = 1' -0" EXT. HORIZ MULLION 3" = 1' -0" 1" INSULATED GLAZING TYPICAL ALUMINUM HORIZONTAL STOREFRONT FRAMING TYPICAL 1" INSULATED GLAZING TYPICAL 1" INSULATED GLAZING TYPICAL ALUMINUM VERTICAL STOREFRONT FRAMING - TYPICAL EXT. VERTICAL MULLION 3" = 1' -0" BACKER ROD AND SEALANT %'' GWB AT INTERIOR TYPICAL (E) WALL ASSEMBLY TO REMAIN 1" INSULATED GLAZING TYPICAL INSULATED GLAZING - TYPICAL ALUMINUM STOREFRONT FRAMING AT JAMB BACKER ROD AND SEALANT - TYP. EACH SIDE (E) BRICK FACADE TO REMAIN EXT. JAMB DETAIL 3" = 1' -0" B.O. EXIST. SOFFIT 10' -0" AFF EXISTING SOFFIT FRAMING TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 5 2012 City of BOIL NG DIVISION Tukwila I" INSULATED GLAZING TYPICAL ALUMINUM STOREFRONT FRAMING - TYPICAL SEALANT - TYPICAL EACH SIDE STAINLESS STEEL SILL PM - SET IN SEALANT EXT. SILL DETAIL 3" = 1' -0" EXIST. CONCRETE SIDEWALK EXIST. CONCRETE SLAB ON GRADE RECEIVED MAR 19 2012 PERMIT CENTER WsIIie[tf Sou thcenter 633 Southcenter Parkway 7bkwIo. WA.. 98188 -2888 206 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME, ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWNC ARE FOR USE ON THE SPECIFIEO PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 824 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: I- zo W f- in 0N m D - 0 ,_ U 0 LL. CO N O W F.- v Q u) z � Q Q z W PERMIT SET MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ SECTIONS AND DETAILS NO WORK THIS AREA - CEILING TO BE PROVIDED BY TENANT LEASE LINE LEASE LINE (E) VACANT TENANT SPACE - NO WORK THIS AREA VACANT TENANT SPACE 100 EXTERIOR ALUMINUM STOREFRONT AND GLAZING - TYPICAL NO WORK TH15 AREA - CEILING TO BE PROVIDED BY TENANT —\ REFLECTED CEILING PLAN 1/2" = 1' -0" LEASE LINE DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. FRAME MATL. RATING DETAILS HDWR GROUP REMARKS FIRST FLOOR HEAD JAMB THRESH. 100 MALL CONCOURSE - TENANT SPACE N/A GLASS 3' -0" x 10' -0" 13/4" GLASS AL NR 2 /A2.I 4/1/A2.I 9/A2.0 1 1,23,4 101 EXTERIOR - TENANT SPACE N/A GLASS 3' -0" x 10' -0" 1 3/4" GLASS AL NR 4/A2.0 11/42.0 3/42.0 2 1,3,4 102 TENANT SPACE - BACK OF HOUSE EXIST. EXIST. 3' -0" x 1' -0" -- -- -- -- -- -- -- -- 5 CORRIDOR REMARKS 413131REVIATION5 1. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS AL ALUMINUM MEETING ALL REQUIREMENTS FOR GLASS DOORS, INCLUDING ADJACENT FL FLUSH DOOR GLAZING ALONG MALL CONCOURSE. FR FRAME 2. PULLS TO BE STAINLESS STEEL. HM HOLLOW METAL 3. DOORS TO HAVE SIGN (I" HIGH LETTERS) LOCATED ABOVE DOORS WITHIN NR NON -RATED TENANT SPACE STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS STOR STOREFRONT OCCUPIED". 4. DOOR THRESHOLD AND CLEARANCE SHALL ACCOMMODATE TENANT FLOOR FINISH. 5. EXISTING DOOR TO REMAIN - MAINTAIN 1 -HOUR RATED ASSEMBLY. HARDWARE GROUPS GROUP 1: DOOR 100 (ENTRY DOOR) I QTY. OVERHEAD CONCEALED CLOSER (CRL) I PR 1" DIAMETER STAINLESS STEEL 12" BACK TO BACK PULLS (CRT GLASS- MOUNTED STRAIGHT) I QTY. OEADBOLT FLOOR RAIL LOCK (CRL DOOR FLOOR RAIL LOCK) 1 QTY. CYLINDER (CRL MORTISE KEYED CYLINDER) GROUP 2: DOOR 101 (ENTRY DOOR) I QTY. SINGLE ACTING CONTINUOUS HINGE I QTY. CONTINUOUS THRESHOLD 1 SET. WEATHERSTRIPPING 1 QTY. CLOSER - LCN 4040 1 QTY. FLOOR STOPS 1 SET. DEADLOCK WITH TWO I5/2" DIA. 5 PIN. CYLINDER I QTY. SURFACE MOUNTED DOOR SWEEP EXTERIOR MALL STOREFRONT STOREFRONT DESCRIPTION (BASIS OF DESIGN) - EXTRUDED ALUMINUM STOREFRONT - KAWNEER TRIFAB 451 T 2" WIDE BY 4 I/2 "DEEP FRAMING - SILL SHALL BE 2" HIGH X 4" PEEP - HEAD SHALL BE 2" HIGH X 4" DEEP - JAMBS SHALL SE 2" WIDE - FRAME FINISH SHALL SE BLACK ANODIZED ALUMINUM - GLAZING SHALL BE MN. I" THICK INSULATED - CLEAR, FULLY TEMPERED SAFETY GLASS PER HEIGHT AND GLAZING REQUIREMENTS - GLAZING SHALL BE SOLARBAN 10 CLEAR TEMPERED GLAZING. ACCEPTABLE MANUFACTURER'S SHALL INCLUDE EFCO (SERIES 403 I) AND ARCADIA (SERIES 451 T) MANUFACTURERS SHALL MATCH KAWNEER BASIS OF DESIGN CRITERIA. INTERIOR MALL STOREFRONT STOREFRONT DESCRIPTION (BASIS OF DESIGN) - KAUINEER TRIFAB 451 SERIES 2" X 49 TYPICAL FRAMES - GLAZING SHALL BE )4" THICK CLEAR TEMPERED SAFETY GLASS - STOREFRONT SYSTEMS SHALL IEE FRONT GLAZED AND INCLUDE GLAZING ADAPTER FOR X" THICK GLAZING - HORIZONTAL MULLIONS - SILL SHALL BE 2" X 4►i" - HORIZONTAL MULLION 514ALL BE 2" HIGH - CORNERS SHALL BE 4X" X44" FRAMES - STOREFRONT FINISH SHALL BE BLACK ANODIZED ALUMINUM - VERTICAL JOINTS IN STOREFRONT SHALL BE )4" WIDE MAXIMUM - BUTT GLAZED SYSTEM WITH 2" X 2" BLACK GLAZING CLIPS AS REQUIRED. OTHER AVAILABLE MANUFACTURERS INCLUDE ARCADIA, EFCO INTERIOR ALUMINUM STOREFRONT AND GLAZING - TYPICAL (E) MALL CONCOURSE —\ INTERIOR ALUMINUM STOREFRONT AND GLAZING - TYPICAL BOTTOM OF (E) MALL CEILING +/- I3' -I0" REVERSE CHANNEL LETTER SIGN - COORDINATE WITH TENANT LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE ALUMINUM STOREFRONT SPECIFICATIONS: BASIC DESIGN WIND LOAD CRITERIA: BASIC WIND SPEED: (3 SECOND GUST) 85 MPH WIND IMPORTANCE FACTOR: 15 WIND EXPOSURE: C SERIES: VG 451 T FRAMING SYSTEM± THERMAL± FRONT SHEAR BLOCK ASSEMBLY OUTSIDE GLAZED WITH I" INFILL WIND LOADS: PROVIDE FRAMING SYSTEM± INCLUDE ANCHORAGE, CAPABLE OF WITHSTANDING WIND LOAD DESIGN PRESSURES IN ACCORDANCE TO THE 2009 IBC. AIR INFILTRATION: THE TEST SPECIMEN SHALL BE TESTED IN ACCORDANCE WITI4 ASTM E283. AIR INFILTRATION SHALL NOT EXCEED 0.06 CFM/FT2 AT A STATIC AIR PRESSURE DIFFERENTIAL OF 624 PSF. WATER RESISTANCE: NE TEST SPECIMEN SHALL BE TESTED IN ACCORDANCE WITH 45111 E 331. THERE SHALL BE NO LEAKAGE AT A MINIMUM STATIC AIR PRESSURE DIFFERENTIAL OF 8 PSF AS DEFINED IN AAMA 501. UNIFORM LOAD: A STATIC AIR DESIGN LOAD OF 20 PSF SHALL BE APPLIED IN THE POSITIVE AND NEGATIVE DIRECTION IN ACCORDANCE TO ASTM E 330. THERE 514ALL BE NO DEFLECTION IN EXCESS OF I /I15 OF THE SPAN OF MY FRAMING MEMBER AT A STRUCTURAL LOAD EQUAL TO 15 TIMES THE SPECIFIED DESIGN LOAD, NO GLASS BREAKAGE OR PERMANENT SET IN TI4E FRAMING MEMBERS IN EXCESS OF 02% OF THEIR CLEAR SPANS SHALL OCCUR. THERMAL RESISTANCE (U- FACTOR: WHEN TESTED IN ACCORDANCE TO AAMA SPECIFICATION 1503 TI4E THERMAL TRANSMITTANCE (U- FACTOR) 5HALL NOT BE MORE THAN: GLASS TO EXTERIOR - 0.41 (LOW E) OR 0,61 (CLEAR) CONDENSATION RESISTANCE (crf): WHEN TEST TO AAMA SPECIFICATION 1503 THE CONDENSATION RESISTANCE FACTOR 514ALL NOT BE LESS THAN: GLASS TO EXTERIOR - 10 FRAME AND 69 GLASS (LOW E) OR 69 FRAME AND 58 GLASS (CLEAR) MATERIALS: ALUMINUM FRAMING AND COMPONENTS 1. MATERIAL STANDARD - ASTM B 221± 6063 -T6 ALLOY AND TEMPER 2. MEMBER WALL THICKNESS - EACH FRAMING MEMBER SHALL PROVIDE STRUCTURAL STRENGTH TO MEET SPECIFIED PERFORMANCE REQUIREMENTS 3. TOLERANCES - REFERENCE TO TOLERANCES FOR WALL THICKNESS AND OTHER CROSS SECTIONAL DIMENSIONS OF STOREFRONT MEMBERS ARE NOMINAL AND IN COMPLIANCE WITH AA ALUMINUM STANDARDS AND DATA. ACCESSORIES: I. FASTENERS - WHERE EXPOSED SHALL BE STAINLESS STEEL 2. GASKETS - GLAZING GASKETS SHALL BE 'EXTRUDED EPDM RUBBER 3. PERIMETER ANCHORS - WHEN STEEL ANCHORS ARE USED PROVIDE INSULATION BETWEEN STEEL MATERIAL AND ALUMINUM MATERIAL TO PREVENT GALVANIC ACTION. 4. THERMAL BARRIER - (TRIFAB VG 451T) KAWNEER ISOLOCK THERMAL BREAK WITH A Y" SEPARATION CONSISTING OF TWO PART CHEMICALLY CURING, HIGH DENSITY POLYURETHANE WHICH IS MECHANICALLY AND ADHESIVELY JOINED TO ALUMINUM STOREFRONT SECTIONS. THERMAL BREAK SHALL BE DESIGNED IN ACCORDANCE WITH AAMA TIR -A8 AND TESTED IN ACCORDANCE TO AAMA 505 SEALANT: DOW CORNING 190 SILICONE SEALANT - MATCH EXISTING SEALANT COLOR (SANDSTONE) GLAZING: SOLARBAN10 VISIBLE LIGHT TRANSMISSION: 63% U -VALUE WINTER: 029 U -VALUE SUMMER: 021 SHGC: 0.21 SHADING COEFFICIENT: 0.31 • TOP OF ALUMINUM STOREFRONT I0' -2" 6" 9 METAL STUD FRAMING AND %I' GWB - TYPICAL ALUMINUM STOREFRONT FRAMING (HEAD) X" THICK TEMPERED GLAZING WIN (2) GLAZING CLIPS AT EACH JOINT TYPICAL \--MALL CONCOURSE (E) CEILING AT MALL CONCOURSE METAL STUD DIAG. BRACING BACK TO STRUCTURE AS REQUIRED MIN. 4' -0" O.C. 6" METAL STUD FRAMING AND HEADER WITH %" GWB TYPICAL. ALUMINUM STOREFRONT FRAMING (SILL) (E) MALL CONCOURSE TILE FINISH FLOOR 0'-0" \--TENANT SPACE —\ FLOOR FINISH BY TENANT WALL SECTION 1/2" =11-0" BOTTOM OF (E) MALL CEILING +/- 13' -I0" REVERSE CHANNEL — LETTER SIGN - BEYOND COORDINATE WITI4 TENANT REFLECTED CE IL INCA PLAN GENERAL NOTES: ■ 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. AREAS DESIGNATED AS 'NO WORK THIS AREA' SHALL REMAIN AS CURRENT CONDITION. THE SPACE 51-1ALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AS REQUIRED. REVIEWED FOR CODE COMPLIANCE APPROVED APR 05 2012 City of Tukwila BUILDING DIVISION Lly J•J LEDGESTONE VENEER ' CULTURED STONE' COLOR: MOJAVE TOP OF ALUMINUM STOREFRONT 10' -2" ALUMINUM STOREFRONT FRAMING (HEAD) )¢" THICK TEMPERED GLAZING WITH (2) GLAZING CLIPS AT EACH JOINT TYPICAL MALL CONCOURSE ALUMINUM STOREFRONT FRAMING (SILL) (E) MALL CONCOURSE TILE FINISH FLOOR 0' -0" In I I I i• 1I I I 1 9 9 3 (E) CEILING AT MALL CONCOURSE METAL STUD DIAL. BRACING SACK TO STRUCTURE AS REQUIRED MIN. 4' -0" O.C. 6" METAL STUD FRAMING AND HEADER WITH %" GUS TYPICAL. A2.0 TENANT SPACE \ WALL SECTION 1 /2" = 1' -0" b1208? FLOOR FINISH BY TENANT RECEIVED MAR 19 2012 PERMIT CENTER WestIle[tf Southcenter 833 Southcenter Parkway Tukwila, WA., 98168 -2888 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT CF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED 'WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTON CARRIES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY ANO SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (206) 624 -2973 MPROVEMENTS TENANT STOREFRONT ISSUE 0 m 0 U 2 Cfl LC) N uJ U 0 I- Q w °° c z(3) wQ J 0 ISSUE PERMIT SET DATE: MARCH 19, 2012 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ REFLECTED CEILING PLAN AND DETAILS . SMSA:1222A3.0 03.0