HomeMy WebLinkAboutPermit D12-102 - HOFFMAN RESIDENCE - UPGRADESHOFFMAN RESIDENCE
3924 S 114 ST
D12 -102
City ofkTukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3351400075
Address: 3924 S 114 ST TUKW
Suite No:
Project Name: HOFFMAN RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D12 -102
Issue Date: 04/05/2012
Permit Expires On: 10/02/2012
Owner:
Name: HOFFMAN STANLEY G
Address: 3924 S 114TH , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
REISSUANCE OF EXPIRED PERMIT D 11 -225. THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF
EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND
STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK
(WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $25,699.00 Fees Collected: $304.27
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -102 Printed: 04 -05 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: _ `
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance o ork. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name:
Date: 41/57/
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D12 -102 Printed: 04 -05 -2012
this requirement.
• •
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -102 Printed: 04 -05 -2012
Pak
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.lva.us
Building Permit No. 1,1_— t O�
Mechanical Permit No. hik.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 3924 S. 114th St.
Tenant Name: Stanley G. Hoffman
Property Owners Name: Stanley G. Hoffman
Mailing Address: 3924 S. 114th St.
King Co Assessor's Tax No.: 3351400075
Suite Number:
New Tenant:
Floor:
❑ Yes m ..No
98168
Zip
Seattle
WA
City
State
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
E -Mail Address: Sharyn.Parker @kingcounty.gov
Day Telephone: (206) 296 -7437
Seattle WA 98108
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Contact Person: Melody Leung
Seattle
WA 98106
or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applications \Forms - Applications On Line \2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFO'ION — 206 -431 -3670
Valuation of Project (contractor's bid price): $ 25,699 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
VI.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
W f\ there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns- Applications On Line \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
825
2ad Floor
825
3m Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
W f\ there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fonns- Applications On Line \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHO ' I .4 ' GENT:
Signature:
Print Name: Timoth
. Fenlason, S
Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Date: /' 1/ Ja,i.
Day Telephone: (206) 624 -2777
Seattle
WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:Wpplications\Fotms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPINCERMIT INFORMATION - 206 -431T 70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
not yet awarded
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Indicate type of plumbing fixtures and/or gas piping outl
Sewer:
ing installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Q
Fixture Type:
Qty
i Fixture Type:
Qty
Bathtub or combination
bath/shower,
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain
water cooler (pe ead)
. -waste grinder,
co '''_- ercial
Floor Drain
Shower, single head trap
Lavatory
Wash untain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water he -r and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
R- . r or alteration of
w. r piping and/or water
. tment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
: ackflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:Wpplications\Forms- Applications On- Line \2009 Applications \I -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
Citoof Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R12 -01243
Initials: WER
Payment Date: 04/05/2012
User ID: 1655 Total Payment: 6,715.15
Payee: PAMELA K KUEHL (PHONE)
SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN
SET TRANSACTIONS:
Set Member Amount
D12 -099 229.85
D12 -100 220.30
D12 -101 334.07
D12 -102 304.27
D12 -103 191.65
D12 -104 228.20
D12 -105 326.62
D12 -106 210.75
D12 -107 210.50
D12 -108 220.30
D12 -109 311.72
D12 -110 172.55
D12 -111 248.95
D12 -112 419.17
D12 -113 503.80
M12 -041 167.70
M12 -042 167.70
M12 -043 177.10
M12 -044 167.70
M12 -045 167.70
M12 -046 167.70
M12 -047 167.70
M12 -048 167.70
M12 -049 167.70
M12 -050 167.70
M12 -051 167.70
M12 -052 167.70
M12 -053 167.70
M12 -054 167.70
M12 -055 225.25
T()TAT,. 229.85
Ci* of Tukwila.
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
•
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA
ACCOUNT ITEM LIST:
Description
TOTAL:
6,715.15
6,715.15
Account Code Current Pmts
BUILDING - RES
MECHANICAL - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
640.237.114
TOTAL:
4,065.20
2,582.45
67.50
6,715.15
- r0;1.-1
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter. Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
14o Fn.: ar1
iz 5
Type f Ins a ti n:
-c` ni.
� ' S 40) A 6
Addres :
.3`:74
-7
�+
Date Called:
I f`� r
S
Special Instructions:
Date Wanted:.,
/"--a m
11.------P-m.
Requester:
12 Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
a ,) tom, /.;V/
; wsa,f_ A, /.>,
A/O V 4541 f li fare►
-
.. !
I
•
l
pector
4.44,u
GE•[.. -.
Date:
4/_ /A
-1
INSPECTION FEE REQUIRED. Pfior to next inspection, fee must be
aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
N./
INSPECTION RECORD .� I
Retain a copy with permit Di 2 ( a '-t-
PERMIT NO. �
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
(1 r)/e' (109)../ - .4�n44,400
Type *inspection:
f .
f A4 2JI./ _ 41176n/
Ad 3 -- -1 ,21.
1 W'Lsr
Date Called:
:«df.L n/ f/ — /SJ /#3
Special Instructions:
Date Wanted:.
�! _
f,
T _.
r a.m`.
•
% 1.1 p.m.
Requester:
Phone No:_
Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
(1 r)/e' (109)../ - .4�n44,400
f .
f A4 2JI./ _ 41176n/
1;
:«df.L n/ f/ — /SJ /#3
nspect
't".
REI SPECTION FEE 4QUIRED Prior to next inspection. fee must be
p at 6300 Southcenter Blvd:. Suite 100. Call to schedule reinspection.
Date:
4/— 2
� PERMIT CO COP •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: 012 -102 DATE: 03 -30 -12
PROJECT NAME: HOFFMAN RESIDENCE
SITE ADDRESS: 3924 S 114 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # _
Revision # After Permit Issued
DEPARTMENTS:
ing r 'vision
Public Works
Fire Prevention
Structural
n
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
n
DUE DATE: 04-03 -12
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route T Structural Review Required n No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
n
Approved with Conditions
DUE DATE: 05-01-12
Not Approved (attach comments) ❑
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Per Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with Lal to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135931
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
Landmark
American Ins Co
LHA135931
03/01/2012
03/01/2013
1
$1,000,000.0003
/06/2012
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.0003
/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
04/05/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
numbing
Piping
City of Tukwila
fiUJLDING DIVISION
REVISIONS
No changes shag be de amen to the scope
of work without prior approval of
Tukwila Building Division.
WT=: Revisions will require a new plan submittal
and may include additional plan review fees.
FZLE CO .,Y
Permit Flo.
Pt ^" r "view approval is subject to errors and omlans.
'ai of construction documents does not authorize
Et: yarn of any adopted coda or ordinance. Receipt
o� Lp roved Field Co IS acknowledged:
4,1e---;,11 Tu."
By
Date:. /4-// 7..
City Of lbkwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
international Fire Code,
international Mechanical Code
,ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
3351400015
LEGAL DESCRIPTION:
HILLMANS C D MEADOW GARDENS 3 IGLU POR VAC 40TH AVE 5 ADJ
BUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
DRAWING INDEX
TO0
A1.0
A2.0
42.1
422
42.3
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 1 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MID LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX
M2.0 BASEMENT, MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS
E1.0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E -mall: SharynParkerskingcountygov
ARCHITECT:
S.M. Stemper Architects PLL.C.
4000 Delr1dge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mall: Jerry *amatemper.com
melody ssmstemper.com
ttmesmstemper.com
ACOUSTICAL ENGINEER:
S54 Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua
E -mail: mohamedessaacousticscom
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Chris Ager
E -mail: ChrisAagreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E -mail: t1m ogdenspbaenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 0200
Boston, 114 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwellsionespayne.com
RECEIVED
MAR 3 0 2012
PERMIT CENTER
VICINITY MAP (NTS)
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (208) 824 -2073
4220
REGISTERED.
aCOn
STARE OF
TROE
INV:TON'.
2124/11
0810.03.1736
0
0
ct
d
Q
Z LLl
O Lu
ce
w
z
w p
E— Z
Z �
0
Z
1—
z
w
0
U)
w
•
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
z
0
1—
z
J
Q
w
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1736
STORAGE
STORAGE
BASEMENT PLAN
1/4" = 1'
NOTE:
1. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
KITCWEN
-1
DINING
ROOM
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OILNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE TWE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 6:00 AM EACH DAY.
HOMEOWNER WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
MD REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 0:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS WATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EST HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, MD WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
1S. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
LIVING
ROOM
PORCH
MAIN FLOOR PLAN
1/4" = 1'
A. SOUTH ELEVATION
B. WEST ELEVATION
PLAN KEYNOTES
j : DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOU ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
/';;1. DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
�`� DOOR SCHEDULE ON SHEET 42.1
3 O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
aINSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMED LNER.
OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT MSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES.
OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/4,22 FOR DETAIL
OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
CLOSET
BEDROOM
2
CLOSET
LAND ING
0
BALCONY
BEDROOM
24" x 24" EXIST.
ATTIC ACCESS
PANEL
CLOSET
NNW
UPPER FLOOR PLAN
1/4" = 1'
C. NORTH ELEVATION
LEGEND
DI
D. EAST ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
r
1 - ACOUSTICAL WINDOW
[LEY
1
col
NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. 42.0
O
WINDOW
DTrs REDUCE FOR
FLOOR / CEILING GRILL
EXISTING KITCHEN EXI4AUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
NOT USED
NOT USED
4111C INSULATION
APR 0 4 2012
City of Tukwila
BUILDING DIVISIO
RECEIVED
MAR 30 2012
PERMIT CENTER
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
IGAS
KITCHEN EXHAUST BAFFLE
GAS METER
Ni
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 621-2777 • FAX (208) 624 -2973
COTT
STATE 0
0810.03.1736
2/24/11
NTERNATIONAL AIRPORT
KING COUNTY
AIP NUMBER
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
5 -53 -0058 -043
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1736
WINDOW TYPES
2
FIXED / SLIDER CASEMENT
WINDOW SCHEDULE
1MND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
,4
DINING ROOM
1
4' -0" x 6' -4"
PAINT/PAINT
SAFETY GLAZING REQUIRED
1/A2.0
B
DINING ROOM
1
4' -0" x 6' -4"
PAINT/PAINT
SAFETY GLAZING REQUIRED
1/A20
C
KITCHEN
2
2' -9" x 2' -6"
PAINT/PAINT
1/42.0
D
KITCHEN
2
2' -10" x 3' -6"
PAINT/PAINT
1/42.0
E
LIVING ROOM
1
3' -4" x 5' -5"
PAINT/PAINT
SAFETY GLAZNG REQUIRED
1/42.0
F
LIVING ROOM
1
4' -0" x 6' -4"
PAINT/PAINT
SAFETY GLAZNG REQUIRED
1/42.0
G
LIVING ROOM
1
4' -0" x 6' -4"
PAINT/PAINT
SAFETY GLAZNG REQUIRED
1/42.0
H
LIVING ROOM
1
4' -0" x 6' -4"
FAINT/PAINT
SAFETY GLAZING REQUIRED
1/42.0
I
BEDROOM I
2
2' -5" x 4' -3"
PAINT/PAINT
Y
1/42.0
J
BEDROOM I
2
2' -5" x 4' -3"
PAINT/PAINT
1/42.0
K
BEDROOM 2
2
2' -5" x 4' -3"
PAINT/PAINT
Y
I /A2.0
L
BEDROOM 2
2
2' -5" x 4' -3"
PAINT/PAINT
1442.0
(E) . EXISTING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND NSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGANST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE - PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT 10 MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) GLOB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT /STAIN TO
MATCH (E) TRIM
ACOUSTICAL WINDOW ASSEMBLY
CARERJLLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERNG
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WNDOW NAILING FIN
WINDOW HEAD
PP'
■
171
`YnW
WnY'
III ( I
WINDOW JAMB
II
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PANT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
0
I0
I
�! I
jF
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
f111 \l
ftl
A■ 3
oak
WINDOWSILL
(E) GWB
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
3/8"
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL SEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
o
RECEIVED
MAR 30 2012
PERMIT CENTER
REVIEWED FOR
CODE COMPLIANCE
,ti APPROVED
APR 0 4 2012
City of Tukwila
BUILDING DIVISION
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824 -2777 • FAX (208) 824 -2973
4220
REGISTERED
ti HIITECT
lil /P'°r'
COTT TEMPE
TATE OF SHINCTON
2/24/11
0810.03.1736
0
0
Cif
J
z
0
z
w
z
z
O
(. )
Ca
MPROVEMENTS
0
Cw
w
w
0
z
I!1
AIP NUMBER
5 -53- 0058 -043
z
O
z
cn
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1736
DOOR TYPES
/
,4 B
FLUSH SCW EXTERIOR
1 LITE W/ SINGLE LEAF STORM
2 PANELS W/ SAFETY GLAZING
W /SAFETY GLAZING
C
EXTERIOR
DBL. LEAF STORM DOOR
W/ SAFETY GLAZING
DOOR
SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY
B
3' -0" x 6' -11"
PAINT/PAINT
HW -I 1 613
DK -4 (Addison)
LOCK -I
1 /A2.I
2
KITCHEN
A
2' -8" x 6' -8"
PAINT/PAINT
HW -I 1 613
DK -I
LOCK -1
2 /A2J
3
LANDING (PAIR DOOR)
5
6' -0" x 6' -8"
PAINT/PAINT
HW -I 1 613
DK -I
LOCK -I
2 /A2J
4
ENTRY
C
3' -0" x 6' -11"
1 /A2.1
5
KITCHEN
C
2' -8" x 6' -8"
2 /A2.I
6
LANDING (DBL DOOR)
D
6' -0" x 6'4"
2 /A2J
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. I'M AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
DOOR HEAD
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RO. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER - STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
0
DOOR JAMB
DOOR SILL
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED
N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUt SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SMALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
bLLIo2
RECEIVED
MAR 30 201Z
PERMIT CENTER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
City of Tukwila
BUILDING DIVISION
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
A. 1-11.TEICT
,,,t "!
C•OTT ? TEMPE.,
STATE OF ! .•HINGTON'
0810.03.1736
2/24/11
0
cc
J
z
O
I-
Q
z
w
0 z
z
0
0
z
AIP NUMBER
MPROVEMENTS
>-
0
w
w
w
0
z
1-
LL
z
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1736
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDER(- AYMENT OVER TOP OF SELF - ADHERING
MEMBRANE. TYP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REVD
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE- PRIMED, GALV. SHEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF - ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- FAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
11
11
L
REMOVE / REPLACE SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAR 3 0 2012
PERMIT CENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
422,0
w. COTT
STATE OF
LTEMP • .
SHINGTON'•
2/24/11
0810.03.1736
H
ce
0
ce
a
J
0
ce
z
w
z
z
0
U
0
Z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
ISSUED
2124111
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
MISC.
DETAILS
A2.2
0810.03.1736
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTEMY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE MD
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 1 -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND 1 in
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
I" MIN
1 1/2" TYP.
MEMBRANE FLASHING AT SILL
i( 5 ir
BUTTERFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
WINDOW NAIL FLANGE
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
11 11
0
0
O
0
O
0
0
0
0 0 0
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
C NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
(E) SHEATHNG
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PRE ARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L J
HEAD FLASHING PREPARATION
�o J
SCALE: NTS
(E) BLDG. PARR
c2.
NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
C5' MEMBRANE FLASHING AT SILL
} SCALE: NTS
INSTALL 514T. METAL
HEAD FLASHING
LINDER (E) BLDG
PAPER.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW I /8" CLEARANCE
BETWEEN FLASHING AND
80T. EDGE OF (E)
- -
[ — �.r_ - - --
SIDING.
TRIMMED EDGE
OF (E) SIDNG,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
R.O. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHORN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
3
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHNG.
6� MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: PETALS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOIIN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
10
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
WINDOW FLASHING INSTALLATION
SCALE: NTS
Al
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 4 2012
City of Tukwila
BUILDING DIVISION
RECEIVE
MAR 3 0 2012
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A ' 'HITECT
0810.03.1736
2/24/11
NTERNATIONAL AIRPORT
MPROVEMENTS
i>'
0
w
W
ct
w
0
LL
AIP NUMBER
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
A A, LB &J H
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1736
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
Cw
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
VD
VTR
w
WB
w/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
OR XX EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
X/Y
CD
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT, MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
SYMBOL
$G-X XX
ABBR
1--"- UP I +
+ f
Si-m.4°=F
+ f +
1\1
DN
UP
VD
RA /EA
-n l RG
><I SA
SA
4fl- •- F RA /EA
SD
0
I�
kj.
EQUIP ID�R �..
x
NG
•
0
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
OUT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
449
<.08 "WG
7 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC '
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
120
449
<.08 "WG
7 "0
EXTERIOR
1,2
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1736
2633
2
120 CFM
120 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE
INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS
oz.
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) 60
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 2 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 60 / (1 X 1/2) = 120 CFM
RECEIVED
MAR 30 2012
PERMIT CENTER
SEPARATE 4
PERMIT AND
APPROVAL
REQUIRED
EXPIRES: 9 /08/2012
S.M. STEMPER
ARCHITECTS
A Profemioml Limited LiabUit,7 Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(206) 624 -2777 • FAX (206) 924 -2973
THE GREENBUSCH GROUP, INC
•• ••• • • •■11)
0 �9M O sWi ! 0 0E sot M l E1% Dz l 9Il 99114
(206) 378 -0589 (208) 378 -0041 FM
0810.03.1736
KING COUNTY INTERNATIONAL AIRPORT
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1736
SEE
EXIT THRU FLOOR JOISTS
AVOID WASTE PIPING
7 "0
(E)SG
(E)RG
(E)RG
-,
0
STORAGE
STORAGE
BASEMENT MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
CEILING
NORTH
FLOOR
(E)SUPPLY
HEAT PUMP
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
FILTER
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
KITCHEN
, DINING
'
ROOM
BATH
DEKI
(E)SG
LIVING
ROOM
(E)SG
(E)sG
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NORTH
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP CONNECTION DETAIL
SCALE: NONE
GM
EAVE
1
(E)sG
BEDROOM
2
NO MECHANICAL
WORK THIS FLOOR
CLOSET
EEDROO')SG
24' x 24' EXIST.
ATTIC ACCESS
PANEL
CLOSET
UPPER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
NORTH
apftml 2
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
MAR 30 2012
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited umuty Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(209) 024 -2777 • FAX (201) e24 -8973
THE GREENBUSCH GROUP, INC
1))
P400 4mE0 �t YECWII I. At0Il I
1800 RlBT SIRED' 8181E all 8632E. 13 16119
(206) 370-0699 (206) 376 -0641 FAX
0810.03.1736
0
a.
Q
J �
‹C w
O al
Q °C
Z w
C)
z 0
0 rt
U <
0
z <t
zi-
w
0
w
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
z
0
H
(9
Lui
z
DATE
2124/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
BASEMENT,
MAIN AND
UPPER FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1736
15/1
L ---0 0
N
BLACK
BLACK BLACK
WHITE
BK
WHITE
RED
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
PANEL
MP
LOCATION:
SERVING:
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
1201240
VOLT,
1
PHASE,
AMP with MAIN
3
WIRE,
BKR
RESIDENCE
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
AIC,
200
15
16
N/A
15
16
N/A
-
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE
AIP
KVA
TYPE
X
LOAD DESCRIPTION
CKT
1
EXISTCKT
24
1
X
20
A
X
20
X
EXISTCKT
2
3
EXIST CKT
30/2
B
20
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
EXIST CKT
4
5
A
20
EXIST CKT
6
7
EXISTCKT
15/2
B
15
EXIST CKT
8
9
A
15
EXISTCKT
10
11
EXIST CKT
3012
B
15
EXIST CKT
12
13
A
20
EXISTCKT
14
15
EXISTCKT
20
B
20
EXISTCKT
16
17
EXISTCKT
15
A
20
EXISTCKT
18
19
EXIST CKT
20
B
20
EXIST CKT
20
21
EXISTCKT
20
A
20
EXISTCKT
22
23
EXISTCKT
20
6
20
EXIST CKT
24
25
EXISTCKT
50/2
A
20
EXISTCKT
26
27
8
20
EXIST CKT
28
29
EXISTCKT
40/2
A
20
EXIST CKT
30
31
B
20
EXIST CKT
32
33
SPACE
A
20
EXIST CKT
34
35
SPACE
B
20
EXIST CKT
36
37
SPACE
A
20
EXIST CKT
38
39
SPACE
B
15
0.01
D
SMOKE DETECTORS
40
41
SPACE
A
42
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN, LOAD
0.01
0.01
KVA
0.04 AMP
COMPUTED LOAD
0.01
0.01
KVA
0,04 AMP
❑ ISOLATED GROUND BUS
❑ FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP
PANEL SKIRTS
❑ SURFACE
•
❑ RAINTIGHTNEMA:3R ENCLOSURE
❑ DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL
❑ INTEGRAL TVSS
FLUSH
•
REMARKS:
FUR
TO FURNACE
POWER SUPPLY
O
STORAGE
STORAGE
BASEMENT PLAN
1/4" = 1'
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
( D
FIRE ALARM SMOKE DETECTOR 120V OPERATED
X
I°'1
ELECTRICAL METER
X
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
1,2
-
THERMOSTAT
24
1
X
X
THERMOSTAT
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
KITCHEN
DINING
ROOM
ELECTRICAL LEGEND
6YI'1130L
DESCRIPTION
SYMEOL
QESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
IIII11
0
DAMPER CONNECTION
❑'
NON -FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
( D
FIRE ALARM SMOKE DETECTOR 120V OPERATED
#-
I°'1
ELECTRICAL METER
@
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
i
TIMER OPERATED SWITCH
— - —
OT
THERMOSTAT
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM,
ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE
LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN .EIGHT HOURS. POWER MUST BE PROVIDED AT
EACH UNIT BEFORE 8: 00 AM & AFTER 5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED.
REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT
LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING
CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE MOTOR RATED TOGGLE SWITCH AS DISCONNECT.
ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH
MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING
SCHEMATIC DIAGRAM.
0 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE
BACK BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 12OVac AND
PROVIDE COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL. SEE GENERAL NOTES FOR CEILING PENETRATION
REQUIREMENTS.
0 HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL
PENETRATION WORK.
O PROVIDE NEW PANEL ADJACENT TO EXISTING. REUSE EXISTING FOR JUNCTION BOX AND INTERCEPT AND EXTEND EXISTING CIRCUITS TO
NEW PANEL. SPLICE SERVICE CONDUCTORS. CUT BACK AS NECESSARY TO PROVIDE CLEAN CONNECTIONS AND TO REMOVE CORROSION
DAMAGE. PROVIDE 2#14&G TYPE NMB CONDUCTOR FOR SMOKE DETECTORS. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR
ANY WALL PENETRATION WORK.
NORTH
��4TH
TO FURNACE
I><
LIMING
ROOM
x
MAIN FLOOR PLAN
1/4" = 1'
z
5E1DROCM
2
CLOSET
ICE D ROOM
24" x 24" EXIST.
,ATTIC ACCESS
PANEL
CLOSET
UPPER FLOOR PLAN
RECEIVED
MAR 3 0 2012
PERMIT CENTER
PER RATE
APPROVAL
L
REQUIRED
S.M,STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
CN•IN.S11S, INO
1011111 4/AIS 1111111t *n. .M
TANN& 1111111141141
,w1119111s M1 AO MO
PAR NEI 4,11
0810.03.1736
KING COUNTY
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
&
NOTES
E1.0
0810.03.1736