Loading...
HomeMy WebLinkAboutPermit D12-108 - ENYEART RESIDENCE - UPGRADESENYEART RESIDENCE 11818 44 AV S D12-108 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400985 Address: 11818 44 AV S TUKW Suite No: Project Name: ENYEART RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -108 Issue Date: 04/05/2012 Permit Expires On: 10/02/2012 Owner: Name: ENYEART JADANNE L Address: 30118 27TH S , FEDERAL WAY WA 98003 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT D11 -231. THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $17,932.00 Fees Collected: $220.30 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -108 Printed: 04 -05 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: `'L — S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 5c,£ /-I14,4iE Date: t /4111- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. doc: IBC -7/10 D12 -108 Printed: 04 -05 -2012 7: Remove all demolition rubble and loose ellaneous material from lot or parcel of gro properly cap the sanitary sewer connections, and properly fill or oth e protect all basements, cellars, septic to ells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -108 Printed: 04 -05 -2012 CITY OF TUKWILA. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila. wca. us AmRs Building Permit No. ?- - i 0 g Mechanical Permit No. 11)''05 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 11818 44th Ave. S. Tenant Name: Jadanne L. Enyeart King Co Assessor's Tax No.: 3347400985 Suite Number: New Tenant: Property Owners Name: Jadanne L. Enyeart Floor: ❑ Yes 21 .. No 98178 Zip Mailing Address: 11818 44th Ave. S. Tukwila WA City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\ Applications \Forms - Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 1 of 6 BUILDING PERMIT INFORIVI' 'ION 206- 431 -3670 Valuation of Project (contractor's bid price): $ 17,932 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes El.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 745 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • • PERMIT:. APPLICATION NOTES —Applicable to all permits in this application's Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED Signature: e Print Name: Timothy J. Fe : Son, SM Stemp: rchitects, PLLC Day Telephone: (206) 624 -2777 Seattle Date: !i'"( i trt- Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Fotms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING e ', •!- � ' w,'�y r.. •- AN6 .: .D y ,G1. .A. S ,+ EPIwPIT N. I�"- .•yM INFORMATION ;'206 =4 3 •.. -7�- .i.P,:f•:�e;'::rv.5• • $ PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outl being insta e .v= r: and the quantity below: Fixture Type: Qty Fixture Type: di iture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet 1, f lothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or:' water cooler (per head) V :''` ood -waste grinder, mercial Floor Drain Shower, single head trap Lavatory \.h fountain Receptor, indirect waste Sinks Urinals Waters~ loset 4 1, Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater ..., or vent `' Industria +. aste treatment intercepto \including trap and vent, e •. at for kitchen type grease i -', eptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Rep. or alteration of w.,i" piping and/or water .i'.tment equipment Repair or alter n of drainage or vent ti„.ing a Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective d ice other than atmospheric= •'. e vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:'•Applicationsl Forms - Applications On- Line/009 Applications \1.2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Citliof Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -01243 Initials: WER Payment Date: 04/05/2012 User ID: 1655 Total Payment: 6,715.15 Payee: PAMELA K KUEHL (PHONE) SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN SET TRANSACTIONS: Set Member Amount D12 -099 229.85 D12 -100 220.30 D12 -101 334.07 D12 -102 304.27 D12 -103 191.65 D12 -104 228.20 D12 -105 326.62 D12 -106 210.75 D12 -107 210.50 D12 -108 220.30 D12 -109 311.72 D12 -110 172.55 D12 -111 248.95 D12 -112 419.17 D12 -113 503.80 M12 -041 167.70 M12 -042 167.70 M12 -043 177.10 M12 -044 167.70 M12 -045 167.70 M12 -046 167.70 M12 -047 167.70 M12 -048 167.70 M12 -049 167.70 M12 -050 167.70 M12 -051 167.70 M12 -052 167.70 M12 -053 167.70 M12 -054 167.70 M12 -055 225.25 TOTAL. 229.85 Ci* of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci. tukwila.wa. us • TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 6,715.15 6,715.15 Account Code Current Pmts BUILDING - RES MECHANICAL - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 640.237.114 TOTAL: 4,065.20 2,582.45 67.50 6,715.15 • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: .A/ W/E 7 .+?f S Type of Inspection: ,in/'T L. Address: ,r/8/6 yy 41/ S Date Called: Special Instructions: Date /Wanted:. 4 - % - / -z a.m. ,tea Requester: Phone No: Approved per applicable codes. a•Corrections required prior to approval. COMMENTS: Z;) L.r , - //11; �) -P(41,7/77 /- , /A/4 /1 -:, J' / peftor: Date: REI SPECTION FEE REQUIR D. Prior to n t inspection. fee must be l/at 6300 Southcenter Blv .. Suite 100. Call to schedule reinspection. ?ENT GO COM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -108 DATE: 03 -30 -12 PROJECT NAME: ENYEART RESIDENCE SITE ADDRESS: 11818 44 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPARTMENTS: 3 Ilding ivision Public Works n Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04-03-12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) n T Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 055 -01 -12 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.0003 /06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.0008 /05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/05/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: Mechanical tectrical t tubing as Piping City of Tukwila BLIII.DING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal cn;I may include additional plan review fee,: >. j FaaE COPY Permit No. P1 ^n rrvieW approval is subject to errors and omts. ions. of construction documents does not aithot7.3 f . ,..olstion of any adopted code or ordinance. R^ccipt of approved Fiotd C�j� : ins is acknowledged: By Date: 11(4 /7 City Of 1Ukwila BUILDING DIVISION REVIEWED FOR CODE C;OMPLiANCE APPROVED APR 0 4 2012 NAL City of Tuiila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODER: 2009 International Residential Code, International Fire Code, international Mechanical Code ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No C.haree) Y B NON SPRINKLERED 3341400985 LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV +' 1 W 140 FT OF FOLG 3 AND N 30 FT OF 4 i3UILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: DRAWING INDEX T0.0 TITLE 51-IEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES A2,0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS 42.2 MISCELLANEOUS DETAILS A2.3 WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABSREV., GENERAL NOTES 4 DWG INDEX M2.0 MAN FLOOR MECHANICAL PLANS AND DETAILS El0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KiNG COUNTY INTL. AIRPORT: Sour! Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E -mail: SharynParkerek1ngcountygov ARCHITECT: SM. Stomper Architects PLL.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Feniaeon, E -mail: Jerryeematemper.com melodyesmstemper.com timeemetemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206. 539.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 2016. 31S. 0569 Fax: 206.318.0641 Contact: Chia Ager E -mail: ChrlaAegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 98102 Ph 206. 232. e63s Fax: 206.162.41$0 Contact: Tim Ogden E -mail: tim ogdenepbeenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. '100 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwellCJonespayne.com RECEIVED MAR 30 2012 PERMIT CENTER VICINITY MAP (NTS) S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (208) 824 -2973 r WI" GOTi i dTLMPE • s ATf" OF t \J NIGTON 0810.03.1832 2/24/11 i- ce 0 0 ct 7:tC —J 0 w F— z � U 0 ft ft C.'? —1 z z W C!) w ce MPROVEMENTS FT NOISE REMEDY AIP NUMBER 5- 53- 0058 -043 z 0 t- o Z C!) w DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 081 0.03.1 832 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES I. CONTRACTOR TO PROTECT OILNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 WITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL 10. WHERE SOFFITS AND /OR MECI4. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING A5 REQ'D AND RE- CONSTRUCT SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WIN THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL 51-1EET ELO FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE I5 EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE &.00 AM. 4 AFTER 5:00 PM 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, MD WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 1S. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. is. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. CLOSET CLOSET 7 f BEDROOM 2 BEDROOM 1 BATH T 1- w 0 1) LAUNDRY ROOM NEW ELECTRICAL PANEL KITCHEN (E) STOVE 24" x 24" EXIST. ATTIC ACCESS PANEL LIVING ROOM 0 MAIN FLOOR PLAN 1/4" = 1' A. EAST ELEVATION B. SOUTH ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. RP. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOP(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 421 OBLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 5/A22 FOR DETAIL. ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH MECHANICAL. OINSTALL VENT BAFFLES) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/42.2 FOR DETAIL. ci: INSTALL VENT BAI'FLE(5) AT EXISTING RIDGE VENT(5) IN ATTIC, REF. 4/422 FOR DETAIL. cD COORDINATE CEILING GRILL WITH MECHANICAL. c SURPLUS BOTH (E) LIVING ROOM AND LAUNDRY ROOM DOORS TO HOMEOWNER OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 161-5" 8' -6" 3' -10" r r Fr- _J L 1 II 1I II L 1 4 18p {NSULAtTION - - - IIj4EIGaIT AAT - . .41UCCCE LI- fit- -E- - - -- ti L_ �r 24" x 24" EXIST. ,ATTIC J 4 1 1 _J L j ACCESS PANEL J TYP. J 28' -9" ATTIC PLAN 1/4" = 1' L C. WEST ELEVATION D. NORTH ELEVATION LEGEND J ___..__. ACOUSTICAL WINDOW I NOT USED EXTERIOR STORK" i DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW 'TYPES T E FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE NOT USED NOT USED APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION ATTIC INSULATION RECEIVED MAR 3 0 2012 PERMIT CENTER SD INSTALL BATTERY OPERATED SMOKE DETECTORS I GAS NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED HITE:CT 0810.03.1832 2/24/11 NTERNATIONAL AIRPORT z 0 U C� Z AIP NUMBER MPROVEMENTS 5 -53 -0058 -043 z 0 z Ltt N d C!) DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1832 WINDOW TYPES I" MIN. k S k 18" MIN. k k SINGLE HUNG/ FIXED /SINGLE HUNG 2 SINGLE HUNG i 3 SLIDER 4 CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE t TRIM FINISH INT./ EXT. f EGRESS SINGLE HUNG/ FIXED /SINGLE HUNG 2 SINGLE HUNG i 3 SLIDER 4 CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE Wx H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM I 6' -0" x 4' -4" PAINT/PAINT SAFETY GLAZING REQUIRED I /42.0 B BEDROOM I 2 2' -9" x 4' -5" PAINT/PAINT I /A2A C BEDROOM I 4 2' -9" x 4'-5° PAINT/PAINT Y I/A2.0 D BEDROOM 2 4 2' -3" x 4' -5" PAINT/PAINT Y I /A2.0 E BEDROOM 2 2 2' -9" x 4' -5" PAINT/PAINT 2/42.0 F LAUNDRY 3 2' -5" x 214" PAINT/PAINT 2/42.0 G LIVING ROOM 3 4' -11" x 2' -10" PAINT/PAINT 2/42.0 H LIVING ROOM 3 5' -10" x 3' -9" PAINT/PAINT 2/42.0 _ (E) a EXISTING NOTE: SURPLUS ALL EXISTING VINYL WINDOWS TO HOMEOWNER (E) CEMENTITIOUS SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT ANO INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) CEMENTITIOUS AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE UJ/ NEW SIDING 4 FAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT Will 111 lki irwri , , 101/1 (E) WALL UNDERLAYMENT (E) WD. PANELING (E) EXTERIOR SHEATHING SELF- ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT CUT (E) WD. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR. SEALANT 4 BACKER ROD 81-1IM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW HEAD CAREFULLY CUT BACK CEMENTITIOUS SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYI"ENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN -`-� WINDOW JAMB CUT (E) WD. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR BACKER ROD 4 SEALANT TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE CEMENTITIOUS SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 1 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) CEMENTITIOUS SIDING 3/4" WD. SILL - STAIN TO MATCH (E) CUT (E) U. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR. WINDOW SILL SELF- ADHERING MEMBRANE (E) WD. PANELING CEMENTITIOUS SIDING - WINDOW DETAIL SET 3 "= 1' -0" (E) U.D. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADI- 4ERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF -ADI- {EKING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT tO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE HELD DETERMINED BACKER ROD 4 SEALANT (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WOOD TRIM TO MATCH E), PAINT /STAIN TO MATCH (E) TRIM ACOUSTICAL WINDOW ASSEMBLY WnW CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLArMENNT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN ----- r �� O. JAMB LINING SEALANT 11 11 SHIM AS NECESSARY FILL GAP W/ BATT WINDOW HEAD INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED WINDOW JAMB (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP UJ/ BATT INSULATION CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW SILL WOOD SIDING - WINDOW DETAIL SET 3" = 1' - 0" BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GLIB TYPICAL \MNDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. bP-IO6 RECEIVED MAR 3 0 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A.; HTE:GT .COTT TEMP E. STATE OF ! .HINGTON 2/24/11 0810.03.1832 0 0 J z 0 z W z z 0 U 0 z MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1832 REVIEWED FOR 1CODE COMPLIANCE 4 APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION • DOOR TYPES ti■ IPA O FLUSH 5CW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW I LITE W/ W/ SAFETY GLAZING C EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB 1 LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 2' -TV' x 6' -8" STAIN/STAIN 14W -I 1 616 DK -2 LOCK -I 1 /A2.I 2 LAUNDRY ROOM B 2' -8" x 6' -8" STAIN/STAIN HW -I 1 616 DK -2 LOCK -I 2 /A2.1 3 LIVING ROOM C 2' -11" x 6' -8" 1 /A2.1 4 LAUNDRY ROOM C 2' -8" x 6'4" 2/A2.1 TYPICAL DOOR SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED N SECTION ®8800 ALL UNLAMINATED GLAZING PANELS N THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SALTY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) CEMENTITIOUS SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDNG PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF- ADHERING MEMBRANE CAREFULLY CUT BACK (E) SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK TOOL FLUSH, AND PAINT FASTENER HEARS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) CEMENTITIOUS SIDING CONTINUOUS SEALANT BEHND Z BAR FRAME STORM DOOR PER SCHEDULE DOOR HEAD I. ii I I k"-•i I AVYRU.'4 Z ra 0 r%" MIN. KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND (E) EXTERIOR SHEATHING HARDWOOD TRIM TO MATCI4 (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS UJEATHER- STRIPPING DOOR PER SCHEDULE WOOD DOOR PER SCHEDULE POOR SH0E 2" MIN. AUTOMATIC DOOR SUJEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL (E) EXTERIOR SHEATHING EXISTING FRAMING HARDWOOD TRIM TO MATCI4 (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE CEMENTITIOUS SIDING - DOOR DETAIL S_ ET 3 "= 1' -0" (E) 111D. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT MD INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADI•IERNG MEMBRANE. COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF - ADHERING MEMBRANE (E) EXTERIOR SHEATHING WOOD TRIM TO MATCH (E), PANT /STAN TO MATCH (E) TRIM CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING DOOR HEAD CONTINUOUS SEALANT BEHIND z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE n `.1 1 2 MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD Al Ir ADJUSTABLE SWEEP , ,`_ ol,„ DOOR JAMB EXISTING FLOOR STRUCTURE SHIM AS NECESSARY FILL GAP W/ GATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING DOOR SILL EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 " =1' -0" bt 108 RECEIVED MAR 3 0 2012 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 4.221 COTT `9 T.Eti4PE. STATE OF 1 . HINGT0N 0810.03.1832 2/24/11 O 0 J z 0 i- < z ce w H z z 0 U 00 z MPROVEMENTS cD w 2 w w 0 z LL 0 w AIP NUMBER 5 -53- 0058 -043 z O I-- c9 Lvt DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 081 0.03.1832 (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PIKE- PRIMED, GALV SHEET METAL UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR 51-1EATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" EXISTING VENT COVER EXISTING ROOF STRUCTURE EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2"X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 11/2 " =l' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 "= 1' -0" NSULATION INSULATION DAM (E) WALL FRAMING BLENDING UNIT ATTACHMENT 1 1/2" = 1' - 0" EXIST. WALL CONSTR. (2) SIMPSON A -34 • EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW #" GALV. HARDWARE CLOTH " cox PLYWOOD AT (3) SIDES I" OWENS CORNING "103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: L AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE At LEAST AS WIDE AS NE EXISTING VENT OPENING. GABLE VENT BAFFLE DETAIL 1 1/2 "= 1' -0" SUSPEND MECH UNIT FROM (E) STRUCTURE RE: MECHANICAL NECH UNIT AND DUCTS - REF MECHANICAL RECEIVED MAR 3 o 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 CGTT TEMPE. STATE Or ? HINGTON • 0810.03.1832 2/24/11 0 0 _I Q w o � � w Q z W w o Z z � gll- = U 0 0 < 0 J Z Q z w 0 0) w MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 I-- z J w DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1832 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E)120. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RA. AT EA END OF SILL. (E) BLDG. PAPER At SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I" MIN MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. Jr 5 Jr Bbl TTERFLY C01�IER FLASHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE At WINDOW SILL (E) BLDG. PAPER AT SILL. 0 i 0 0 0 0 O 0 0 0 0 0 MEMBRANE FLASHING PREVIOUSLY APPLIED 10 WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW �~ NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION (E) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SIHOUN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUIN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HA5 BEEN INSTALLED. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS WHERE RE (E) BLDG HEAD t0 FOR INSTA HEAD FLA WINDOW TR (FOLLOW UIRED, TRIM APER AT PARE LATION OF ING AND L J $1 HEAD FLASHING PREPARATION SCALE: NTS STEPS). (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2■ MEMBRANE FLASHING AT JAMB / SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ( j INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. C5 INSTALL 514T. METAL HEAD FLASHING UNDER (E) BLDG PAPER MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHO(LN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1 /8" TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LEARANCE BETWEEN FLASHING AND SOT. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOO N EXTEND 1 -1/2" BEYOND R.0. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 3" tY - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADWEARING MEMBRANE FLASHING TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER t0 MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. SCALE: NTS (E) SIDING (E) BLDG. PAPER. BENEATH SIDING WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETU,EEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD of SEALANT AND BACKER ROD IN GAP. WINDOW FLASHING INSTALLATION SCALE: NTS D1.1= X08 RECEIVED MAR 30 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 • City of Tukwila BUILDING DIVISION S,M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 4220 REGISTERED A,, H ITE:CT C•OTT TEMPE ,STATE OF . HINGTON 0810.03.1832 2/24/11 F- IX 0 J z 0 I- Q W z O U 0 z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 z J DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1832 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTUH CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP H VAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX OR M. DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. SYMBOL SG -X XXX ABBR IL" I'DNI f f .5+ + r + r■1 X I- 0- I- e � EQUIP ID#`►R . NG I ■1 • 3 0 D'a DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) SA LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM A STATIC PRESSURE _ INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" CEILING DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1832 802 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION J MIN VALUE 'NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. DID - -i08 MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) l5 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION j QF = 45 / (1 X 1/2) = 90 CFM RECEIVED MAR 3 0 2012 PERMIT CENTER SEPARATE 4 PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Fmd'ee.Lonst Limited ISO M , Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (2011) 004 -0777 • FAX (800) ee4 -ee179 THE GREENBUSCH GROUP, INC ))) AU010 VOED tat 201 OIDOEE 111 1900 9E9f 9116L<f 91EIE 701 20011.2 i1 90119 (200) 37B -0609 (906) 378 -0041 FAX 0810.03.1832 KING COUNTY INTERNATIONAL AIRPORT MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 Z 0 L:c H Z DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1832 SEE CEILING GRILLES 7" TYP 4 "0 25 BEDROOM TYP LAUNDRY ROOM 4 "0 SEE 7 "0 KITCHEN LIVINGrt ROOM U SG -1 140 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -O" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN HOLD TIGHT TO STRUCTURE RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS ATTI C USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC BASEBOARD HEATERS. DUCT PER PLAN FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN ATTIC. USE EXISTING ATTIC ACCESS HATCH FOR MAINTENANCE AND ELECTRICAL ACCESS. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER 2. SEE PLANS FOR VOLUME DAMPER LOC 3. CEILING SUPPLY INSTALLATION SHOWN, COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE MANUFACTURER'S WRITTEN INSTRUCTIONS. Al1ONS. RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE aft-109 SEPARATE E APp MITAND REQUIRED 0 RECEIVED MAR 3 0 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Prof•isonal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, RA 98108 (209) 024 -2777 • FAX (206) 624 -2979 THE GREENBUSCH GROUP, INC A0oue00N,_ Mic10_/ VIDEO & YEnw40AL o G* * 1ao0 EEaf 182.1 8 EMT 9212 101 11209E, 12 11111 (206) 376 -0529 (206) 376 -0041 FAX 0810.03.1832 0 a.. J 0 Q O L.L. Z Ce W z gu- z O 0 O U < (.9 Z Q ZI- W co 0 W MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 z CIS C!) DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1832 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4, WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. O HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. 0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. PANEL MP LOCATION: SERVING: 0810.03.1832 SYMI5OL DESCRIPTION 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR PH RESIDENCE AIC, 200 AMP with MAIN 16 15 I I I 1 I DAMPER CONNECTION CKT LOAD DESCRIPTION TYPE KVA ALP PHASE NP KVA TYPE FIRE ALARM SMOKE DETECTOR 120V OPERATED LOAD DESCRIPTION CKT 1 EXISTING LOAD FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED SWITCHES (ON, TIMER) AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. 40/2 A TIMER OPERATED SWITCH 4012 X TO EXISTING LOAD 2 3 B 4 5 EXISTING LOAD 30/2 A 20/2 EXISTING LOAD 6 7 B 8 9 EXISTING LOAD 20/2 A 6012 EXISTING LOAD 10 11 B 12 13 EXISTING LOAD 20/2 A 2011 EXISTING LOAD 14 15 B 20/1 EXISTING LOAD 16 17 EXISTING LOAD 15/1 A 2011 EXISTING LOAD 18 19 EXISTING LOAD 15/9 B 20/1 EXISTING LOAD 20 21 EXISTING LOAD 15/1 A 2011 BLENDING UNIT 22 23 EXISTING LOAD 30/1 B 2011 SMOKE DETECTORS 24 25 A 26 27 B 28 29 A 30 PHASE LOAD PHASE A= KVA, PHASE B� KVA. LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ISOLATED GROUND BUS ❑ FEED THRU LUGS MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE • • RAINTIGHT NEMA -3R ENCLOSURE EI DOUBLE LUGS SERVICE ENTRANCE LABEL INTEGRAL FLUSH • • TVSS • REMARKS: 15/1 /`1 BLACK L —O N WHITE BK BLACK BLACK WHITE RED WHITE 4, SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMI5OL DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION IG LIGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 16 15 I I I 1 I DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH ® MAST, WEATHERHEAD SQ' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN @ FIRE ALARM SMOKE DETECTOR 120V OPERATED ---.- Eal ELECTRICAL METER 0 FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED SWITCHES (ON, TIMER) AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. 1 TIMER OPERATED SWITCH — - — X TO THERMOSTAT MECI-1,4NICAL % ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH PROVIDE NEW S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONNECT TO NEW BREAKERS. DEMO EXISTING ELECTRICAL PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL LAUNDRY ROOM KITCI --WEN LI \/INCA DOOM MAIN FLOOR PLAN 1/4" = 1' RECEIVED MAR 3 0 2012 PERMIT CENTER b D-7109 NORTH PE�RAMITAND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ENGINEERS. IMO OM MUM On ow SIM SIM TAMA NA MOW= 0810.03.1832 1— w 0 0 ce J z 0 LL w z z 0 V 0 Z MPROVEMENTS > 0 w 2 w w 0 z LL_ /)�/ LL 1— z AIP NUMBER 5 -53 -0058 -043 Z O H C9 z co DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1832