Permit D12-109 - KALALAU RESIDENCE - UPGRADES
KALALAU RESIDENCE 12048 44 PL S D12-109 City otI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400860 Address: 12048 44 PL S TUKW Suite No: Project Name: KALALAU RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -109 Issue Date: 04/05/2012 Permit Expires On: 10/02/2012 Owner: Name: KALALAU PATRICK K +DESIREE A Address: 12048 44TH PL S , SEATTLE WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT D11-232. THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $26,689.00 Fees Collected: $311.72 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -109 Printed: 04 -05 -2012 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: - J - (0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo . . - o o . I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: q(41/ z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDPI'fONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D12 -109 Printed: 04 -05 -2012 this requirement. • • 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -109 Printed: 04 -05 -2012 CITY OF TUKWIL A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www.ci.tukwila.tiva.us Building Permit No. T) ) 10 .7 Mechanical Permit No. M (e)-' 0S- Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12048 44th PI. S. Tenant Name: Patrick K. and Desiree A. Kalalau Property Owners Name: Patrick K. and Desiree A. Kalalau Mailing Address: 12048 44th PI. S. King Co Assessor's Tax No.• 3347400860 Suite Number: New Tenant: Floor: ❑ Yes ..No 98178 Zip Tukwila WA City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications \Forms - Applications On Line\2009 Applications\I -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORIV PION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 26,689 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Appli cations \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lgt Floor 1,310 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Appli cations \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PLUMBING AND GAS PIPIN RMIT INFORMATION — 206 -4370 'PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlet being ewer: lled and the quantity below: Fixture Type: Qty Fixture Type: it - "' ' ixture Type: Qty Fixture Type: , Qty Bathtub or combination bath/shower Bidet ; Clothes washer, domestic - Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) , •od -waste grinder, co k ercial Floor Drain Shower, single head trap Lavatory ,; Was i •untain Receptor, indirect waste Sinks Urinals Water CF .et Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater .,0 or vent ±" Industrial w' - treatment interceptor, in • ing trap and vent, except "o kitchen type grease interce` ors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair ialteration of wate 41 ping and/or water tre.x ent equipment Repair or alteration • e, drainage or vent pipin ; Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 e . ckflow protective ; `i evice other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device ' other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter +'�_ Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications \Forms - Applications On- Line\2009 Applications \I-2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 • • PERMIT APPLICATION NOTES APphcable to all permits in th s.application • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED. Signature: Print Name: Timothy J. Fenl -son, SM Ste - r Architects, PLLC P Mailing Address: 4000 Delridge Way SW, Suite 200 Date: ."4q. UitaA r Z Day Telephone: (206) 624 -2777 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H :'Applications `.Forms - Applications On Line'2009 Applications',..I -2009. Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 Ciyof Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -01243 Initials: WER Payment Date: 04/05/2012 User ID: 1655 Total Payment: 6,715.15 Payee: PAMELA K KUEHL (PHONE) SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN SET TRANSACTIONS: Set Member Amount D12 -099 229.85 D12 -100 220.30 D12 -101 334.07 D12 -102 304.27 D12 -103 191.65 D12 -104 228.20 D12 -105 326.62 D12 -106 210.75 D12 -107 210.50 D12 -108 220.30 D12 -109 311.72 D12 -110 172.55 D12 -111 248.95 D12 -112 419.17 D12 -113 503.80 M12 -041 167.70 M12 -042 167.70 M12 -043 177.10 M12 -044 167.70 M12 -045 167.70 M12 -046 167.70 M12 -047 167.70 M12 -048 167.70 M12 -049 167.70 M12 -050 167.70 M12 -051 167.70 M12 -052 167.70 M12 -053 167.70 M12 -054 167.70 M12 -055 225.25 TC)TAL. 229.85 Cilo of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukw ila. wa. us • TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 6,715.15 6,715.15 Account Code Current Pmts BUILDING - RES MECHANICAL - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 640.237.114 TOTAL: 4,065.20 2,582.45 67.50 6,715.15 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 YL (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Hil- LALr97/ ,s Type of Inspection: /= A/)4 L Address: /2 -0 y<° 4/41 Pi-- S Date Called: Special Instructions: Date Wanted:. -- 6 i 3 - /,z ,art, p.m. Requester: Phone No: A'd proved per applicable codes. Corrections required prior to approv / COMMENTS: G Vor on it • ISte (AJ f ri R : IN PECTION FEE REQUIR D. Prior to nest inspection. fee must be p. id • t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -109 PROJECT NAME: KALALAU RESIDENCE SITE ADDRESS: 12048 44 PL S X Original Plan Submittal Response to Correction Letter # DATE: 03 -30 -12 Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: , ding Di iv sion Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 04 -03 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -01 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/05/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: lintuchanical arEiectrical [(Plumbing 131as City of Tukwila BUILDING DIViSI©iN, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ! t'f!17':rstisfons will require a new plan submittal 1 and may include additional plan review fees. 1 F L"' COPY Permit No. t041 Ph r"v!ew approval is subject to errors and omissions. /, ! of construction documents does not authorize 1, r {ios of any adopted code or ordinance. RecGi t a; : �ruTred Fiala . •;;., s r owledged: By Date:..,.,....�a1. /!Z City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012. fI City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, international Mechanical Code 7ONNG: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED 3341400860 L DESCRIPTION: HILLMANS EGAL MEADOW GARDENS DIV • 1 LESS NP RIW AKA TUKWiLA LOT CONSOLIDATION L02 -042 REC 20021125001881 BUILDING AREA: No change to building Footprint. Addition:. Remodel: Sound Insulation: DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES A20 WINDOW TYPES, SCHEDULE 4 DETAILS A2] DOOR TYPES, SCHEDULE 4 DETAILS 42.2 MISCELLANEOUS DETAILS A23 WINDOW FLASHNG DETAILS MID LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E -mail: Sharyn.Parkerslcingcounty.gov ARCHITECT: 511. Stamper Architects PLL.C. 4000 Delrldge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerry*smetemper.com melodyeem8temper.com tlmeemetemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. SA 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGNEER: The Greenbuach Group 1900 UJest Nickerson St., Suite 201 Seattle, UJA 98119 Ph 206. 318. 0569 Fax: 206.318.0641 Contact: Chris Agar E -mail: C1rlsAagreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcriatreswest.com REGULATED MATERIALS: P55 Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenapbeenv:com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. $200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwellejonespaynacom ECEIVED MAR 3 0 2012 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 4220 REGISTERED i\ EIITECT 1 /!I P'1� T•EM Pr. a3FE NGTGN SCOTT 1 MATc OF 0810.03.1833 2124111 O 0 dC 0 z ce w 1- z z 0 U Z MPROVEMENTS 0 W 2 LU w 0 Z u_ Q w CID L=l LLI AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1833 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT TNIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL EE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02051 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. El 11 CLOSET 0 BEDROOM 2 BASEMENT 0 1 FUR J BEDROOM 3 BASEMENT PLAN 1/4" = 1' f E I0 NOTE: KNOB AND TUBE WIRING PRESENT. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS ,4T THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL RAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5 :00 PM TO S:00 AM EACH DAY. I OMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS N NE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SWEET FOR WINDOW REPLACEMENT. O. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'0 AND RE- CONSTRUCT SIELVMGx IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS WATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. U HERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 410 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMIP1 POWER OUTAGE IS Eli HOURS. POUER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. 4 AFTER 5:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY NAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 24" x 24" EXIST. ATTIC ACCESS PANEL COVERED DECK BEDROOM C BATI -1 1 . I DINING ROOM KITCHEN MAIN FLOOR PLAN 1/4" = 1' A. WEST ELEVATION CARPORT ROOF 1 B. NORTH ELEVATION PLAN KEYNOTES 12 —6 11 — Ifni -- 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS WALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. / f 0 7. � — I�IIl��1111�1 24" x 24" EXIST. I— -1 r i-1 — ATTIC ACCESS I 1 PANEL -� _ I I L - - 0 T� I 1 - - - - - - - - - - 1 I ��� � 1 C —J/I /I \I I 1 / f \ I / - - - - - i Y,-.^. I - .... /- - - '1I_ RAI� INSULA'1:ICN1� HFJ If AT EXIST. A IC L-- — EpSPANE_L I- - - _ 1 - - __1 - - - - _ -_- - - - - -� i- �- - -�- . 1__I - . - _ 0 _ - - _. =1 _. _— L 1 1 - - - - - - - - 1-1" - - - 24 x. 24!' EXIST. . - - - - - - . I 1 Alf C HESS PANEL r �- �= MIMI 24' -4" B. NORTH ELEVATION PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SWEET A2.0 ODDOOR EMOLISH SCHEDU EXISTLE ING ON DSHEET 4OOR(S), 2.1 FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. NStALL VENT BAFFLE(5) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/422 FOR DETAIL. OINSTALL VENT BAFFLE(S) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL. ® INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL. 0 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH MECHANICAL. cIDINSTALL NEW THERMOSTAT: COORDINATE WIN MECHANICAL. DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SWEET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR OWITH 'MN PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR WARDWARE SET. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS WALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. EAST ELEVATION 11)17„-- D. SOUTH ELEVATION LEGEND f _____ ACOUSTICAL WINDOW I 1 NOT USED EXTERIOR STORM DOOR DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL EXISTING KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE NOT USED RECEIVE MAR 3 0 2012 PERMIT CENTER ATTIC ACCESS PANEL ATTIC INSULATION fiD INSTALL BATTERY DETECTORS I:011 REVIEWED FOR CODE COMPLIANCE ' APPROVED APR 0 4 2012 City of Tukwila 3UILDING DIVISI KITCHEN EXHAUST BAFFLE GAS METER ON SASTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 90100 (208) 624 -2777 • FAX (20B) 824 -2973 REGISTERED A ,HITECT 0810.03.1833 2/24/11 NTERNATIONAL AIRPORT KING COUNTY MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1833 WINDOW TYPES 2 SINGLE HUNG SLIDER 3 VINYL HORIZONTAL SLIDER 4 CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 4' -0 "x 4' -5" STAIN/PAINT - - I /A2.0 LIVING ROOM I 2' -5" x 4' -5" STAIN/PAINT I /A2.0 C BEDROOM 1 4 2' -4" x 4' -6" STAIN/PAINT Y 1/42.0 D BEDROOM 1 I 2' -4" x 4' -6" STAIN/PAINT SAFETY GLAZING REQUIRED I /42.0 E DINING ROOM 2 3' -S" x 3' -8" STAIN/PAINT SAFETY GLAZING REQUIRED 1/42.0 F PINING ROOM 2 4' -1I" x 4' -5" STAIN/PAINT SAFETY GLAZING REQUIRED I /A2.0 G DINING ROOM 3 6' -I0" x 5' -0" STAIN/PAINT SAFETY GLAZING REQUIRED I /42.0 H KITCI-IEN 2 2' -4" x 2' -3" STAIN/PAINT I/42.0 1 LIVING ROOM I 2' -4" x 4' -4" STAIN/PAINT I /42.0 J LIVING ROOM 2 3' -1" x 3' -11" STAIN/PAINT 1 /42.0 K LIVING ROOM 2 4' -0" x 4' -3" STAIN/PAINT I /A2.0 L BEDROOM 2 2 4' -4" x 3' -0" STAIN/PAINT SAFETY GLAZING REQUIRED Y 2/42.0 M BEDROOM 2 2 4' -S" x 4' -0" STAIN/PAINT SAFETY GLAZING REQUIRED 2/42.0 N BEDROOM 3 2 4' -4" x 2' -2" STAIN/PAINT SAFETY GLAZING REQUIRED 2/42.0 0 BEDROOM 3 2 4' -4" x 2' -2" STAIN/PAINT SAFETY GLAZING REQUIRED CUT SILL TO 26" AFF FOR EGRESS (E) HT. 36" Y 2 /42.0 (E) • EXISTING TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 ACCESSORIES TO MATCH (E) PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD SOLID P.T. BLOCKING (E) EXTERIOR SHEATHING PRE- PRIMED GALV. JAMB FLASHING LAP INTO SILL PAN FLASHING. EMBED LAP IN SEALANT. FIELD PAINT FLASHING - COLOR TO BE SELECTED N THE FIELD SILL PAN FLASHING WINDOW HEAD (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), PAINT /STAIN t0 MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) SACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER !BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. JAMB FLASHING SILL VINYL UNDER SILL TRIM NEW BLOCKING WINDOW JAMB IUD. JAMB LINING. FINISH TO MATCH (E) BACKER ROD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING t0 MATCH (E) (E) BACKER BOARD (E) VINYL SIDING WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 "= 1' -0" SELF - ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GUS (E) BACKER BOARD (E) VINYL SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING MD EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 ACCESSORIES TO MATCH (E) HEAD VINYL UNDER SILL TRIM PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO SE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY EXISTING CONC. WALL PRESSURE TREATED WOOD (E) EXTERIOR SHEATHING C TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED SILL PAN FLASHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE CLOSED SILL PAN WINDOW HEAD as ACOUSTICAL WINDOW ASSEMBLY. USE TAP -CON SCREWS FOR INSTALLATION AT (E) CMU WALL WINDOW JAMB (E) WALL UNDERLAYMENT SELF- ADHERING MEMBRANE CUT (E) GWB AS REQUIRED. REPLACE GWB AT HEAD AND JAMB LINERS. PATCH TO MATCH (E) TEXTURE AND PAINT FULL EXTENT OF WALL TO MATCH (E) WALL COLOR TAPE AND FEATHER MUD JOINT SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP 11./ BATT INSULATION BREAK METAL OVER I X PAINTED HARDWOOD LINER AT SILL AND JAMBS, TYP. SEALANT 4 BACKER ROD CUT (E) GLOB AS REQUIRED. PATCH TO MATCH (E) TEXTURE AND PAINT FULL EXTENT OF WALL TO MATCH (E) WALL COLOR TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED SILL VINYL UNDER SILL TRIM CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING TO MATCH (E) (E) BACKER BOARD (E) VINYL SIDING WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 " =1' -0" METAL CORNER At GUS CORNERS 2 "X8" PRESSURE TREATED WOOD (E) CONCRETE WALL "P10--H 01 RECEIVED MAR 3 0 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 • City of Tukwila BUILDING DIVISION S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 4220 REGISTERED A ITE:CT SCOTT STATE OF 'TEMPE- iSHINGTON 2/24/11 0810.03.1833 i- ce O 0 ct J z O i- < z OC w 1- z z 0 U O z MPROVEMENTS 0 w w w c/) O z Q J Z w 0 w AIP NUMBER 5 -53 -0058 -043 z O z_ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1833 l DOOR TYPES 0 a 4 FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW W/ RECTANGLE LITE AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT C FLUSH SCW HALF -LITE W/ 2 PANELS W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING E FLUSH SCW INTERIOR DOOR DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 3' -0" x 6' -8" STAIN/STAIN WW -I / 616 DK -2 LOCK -I 1/A2.1 2 DINING ROOM B 3' -0" x 6' -8" STAIN/STAIN I-1W -1 / 616 DK -2 LOCK -I 1 /A2.1 3 BEDROOM 3 B 2' -S" x 6' -2" STAIN/STAIN HW -I / 616 DK -2 LOCK -I 1 /A2.1 4 BASEMENT C 2' -S" x 6' -2" STAIN/STAIN HW -I / 616 DK -2 LOCK -I 1 /A2.1 5 LIVING ROOM D 3' -0" x 6' -8" 1 /A2.1 6 DINING ROOM D 3' -0" x b' -8" 1 /A2.1 1 BASEMENT D 2' -S" x 6' -2" 1 /A2.1 S BEDROOM 3 (INTERIOR) E 2' -0" x 6' -2" STAIN/STAIN WW -I / 616 DK -5 NA 2/A2.1 S BEDROOM 2 (INTERIOR) E 2' -6" x b' -2" STAIN/STAIN WW -I / 616 DK -5 NA 2/42.1 10 BEDROOM 3 D 2' -S" x 6' -2" 1 /A2.1 (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEHIND Z 6AR FRAME STORM DOOR PER SCHEDULE SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) PRE- PRIMED FF GALV SHEET METAL FLASHI UNDER SELF- ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE JAMB BEYOND );Iligl;114 2" MIN. (E) EXTERIOR SHEATHING (E) BACKER BOARD SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), FAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB VINYL SIDING 3 "= 1' -0" DOOR SILL DOOR DETAIL SET 2x CEILING FRAMING CONNECTED TO UNDER SIDE OF EXIST. TRUSS FRAMING W/ ONE LAYER, 5 /S" GWB, TAPED, FINISHED, PRIMED AND PAINTED 2 COATS WOOD BLOCKING HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH - - \` (E) TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KEW IN CONTINUOUS WEATHER STRIPPING ..r A, A Iv SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT HARDWOOD TRIM TO MATCH (E), PANT /STAIN TO MATCH (E) TRIM WOOD FRAME SURFACE APPLIED CONTNUOUS WEATHER STRIPPING KERF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE POOR SHOE DOOR HEAD AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL HARDWOOD TRIM TO MATCH (E), PAINT/STAN TO MATCH (E) TRIM INTERIOR DOOR PER SCHEDULE EXISTING FRAMING HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM DOOR PER SCHEDULE INTERIOR - DOOR DETAIL SET 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS 114 THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. RECEIVED MAR 3 0 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 • City et rukwila BUILDING DIVISION • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED A- 'HITEC1 .SCOTT TATE OF 0810.03.1833 2/24/11 0 cL J z 0 z w 1- z z 0 0 00 z MPROVEMENTS 0 Cw w ce w 0 z LL 0 AIP NUMBER 5 -53- 0058 -043 0 F- 0 Lctz fly co DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN A A, LB &J H DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1833 (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PRE- PRIMED, GALV SHEET METAL UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED 11 11 II II SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3" = 1' - 0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE 1 1..........,...................................................., CROSS SECTION EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. RIDGE VENT BAFFLE DETAIL 11/2 " =1' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 " =1' -0" PIVOT HINGE CAULKING ADHESIVE ATTIC HATCH DETAIL 3 " =1' -0" INSULATION INSULATION DAM (E) WALL FRAMING INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS 1 24" O.C. EXTEND BLOCKING TO (E) CEILING JOISTS (TYP) (E) GWB SNAP FRICTION CATCH REMOVABLE DOOR PAINT DOOR AND FRAME TO MATCH (E) COLOR OF CEILNG 01 EXIST. WALL CONSTR (2) SIMPSON A -34 1 EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW i" GALV. WARDWARI= CLOTH " CDX PLYWOOD AT (3) SIDES I" OWENS CORNING '103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: 1 AFTER FABRICATION, BAFFLE SHALL 13E SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTNG VENT OPENING. GABLE VENT BAFFLE DETAIL 11/2 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 3 0 2012 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 96106 (206) 624 -2777 • FAX (206) 824 -2973 4220 ,ofture. JCOTT STATE OF 0810.03.1833 2/24/11 TEMPS. HINGTON' O 0 J 8 Q z w O � 1- w aC °C Z w z z � Z � 0 0 (' J Z Q ZI- w 0 0) w MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 c9 z cn cn DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1833 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAP SILL MEMBRANE FLASHING I -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 i" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING Ilj" MIN MEMBRANE FLASHING AT SILL s SU1TEiILY CORINER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE. �- EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL E3ETllEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. 4 11 11 �$� �'� �� ; �x �y 3" .2 `Arw� v' 7p} kv`5 �ia � O o 0 O ��?+� S:kf �4 �'� O O 0 O k'f� •. Y�yi �4�, ' "' }"�f �jr� ��JU'7"rR� h�, (��`y��✓��Mt .�i � �Fa�+r y��r` �y� �}`.� O O O iL� 4„ 4 '�'ank`�h,.f MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAP ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION (E) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r WHEN RE IRED, TRIM (E) BLDG APER AT HEAD TO PARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRI (FOLLOW STEPS). L J 8 HEAD FLASHING PREPARATION } SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1/2" BEYOND EDGE OF OPENING AT HEAD, JAM85, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 3jr, TYP. �'�' �$� �'� �� ; �x �y 3" .2 `Arw� v' 7p} kv`5 �ia � � fi f�� ��?+� S:kf �4 �'� k'f� •. Y�yi �4�, ' "' }"�f �jr� ��JU'7"rR� h�, (��`y��✓��Mt .�i � �Fa�+r y��r` �y� �}`.� `�L�y' iL� 4„ 4 '�'ank`�h,.f t $t.� 0 y �q. •``r�4^� 'k. 'P �4'�M {y�� dept' � YrM1 "N'� Mil yi t�k x' �Ai' INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. O INSTALL 514. METAL HEAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDNG BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. ALLOW 1/8" CLEARANCE BETWEEN FL4SHING AND SOT. EDGE OF (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING 10 OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. '- INSTALL JAMS FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED N 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED t0 AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 RJR TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. 1_ O 1 J t WINDOV SCALE: NTS WINDOW FLASHING INSTALLATION RECEIVED MAR 30 gg12 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City onaukvvila BUILDING DIVISION S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 REGISTERED AKHITECT 0810.03.1833 2/24/11 H O ce d J Z 0 z w z 0 U 0 Z MPROVEMENTS 0 ctw w w 0 z U Q J a z w 0 AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1833 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB w/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPI CAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ARBR XX OR .XX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y / / //rid / / /ii EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 6. 7. 10. 11. 12. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG —X -y xXX DN UP -I-a ,DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SA -01— 4N- I— RA /EA SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH CI, OR THERMOSTAT EQUIP ID# EQUIPMENT LOCATION II NG• • 7 0 D'4 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 337 E.08 "WG 7 "16 EXTERIOR 15 16 15 16 N/A 15 16 N/A — MOTOR OPERATED DAMPER 24 1 X X X 1,2 — THERMOSTAT 24 1 X X X 1 REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR: 90 337 E.08 "WG 7 "16 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1833 1456 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. 17l9_ -Ind THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (SEGR X F) QR = (FROM TABLE 403.8.1) 4,5_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM RECEIVED MAR 3 0 2012 PERMIT CENTER PERM PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS k Professional Limited Uaemty Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98100 (209) 824 -8777 • FAX (208) 824 -2673 THE GREENBUSCH GROUP, INC ))) ,000"00 Near iam ot'i sN0121 °1 ;g (200) 379 —OB66 (208) 379-0841 FAX 0810.03.1833 ct 0 a_ J z 0 z w z KING COUNTY co z w w 0 0 0 w w w co O z Lai_ U ce cc AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1833 :3::::--- SEE BEDROOM 3 ESGN (E)SG t3EDROOM 2 BASEMENT MECHANICAL PLAN SCALE: 1 /4" = 1' -0" CEILING S OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC FLOOR z fX 1- w rr w J 0 0 w w FURNACE OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE NORTH 24' x 24' EXIST. ` ATTIC ACCESS \ PANEL COVERED DECK GAS METER L- BEDROOM BATH 1 (E)RG LIVING ROOM DINING ROOM KITCHEN MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CARPORT ROOF 1 J CAULK FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP CONNECTION DETAIL SCALE: NONE NORTH DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXIS11NG FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED MAR 30 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited LU.Mlip company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) a24 -2?71 • FAX (boa) 624 -8979 THE GREENBUSCH GROUP, INC ))1 NLIO 11LEO R YEO W4 . EN06EE0110 I x�sf 5I16ET 81111E 901 9110112. 16 N110 (206) 370 -0509 (206) 379 -0041 FAx 0810.03.1833 0 0 C J z 0 z w z z 0 0 z MPROVEMENTS >,. 0 w w w O z u_ Q 0 AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1833 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN 5:00 PM. ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. a PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. 0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. PANEL MP LOCATION: SERVING: 0810.03.1833 SYMBOL 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G: RESIDENCE AIC, EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. 112 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. 16 III CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 EXISTING LOAD —.- 1E3 2011 A FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED 100/2 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. i EXISTING LOAD 2 3 EXISTING LOAD X ® 20/1 X B 1 4 5 EXISTING LOAD 2011 A 50/2 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH EXISTING LOAD 6 7 EXISTING LOAD 20/1 B 8 9 EXISTING LOAD 2011 A 30/2 EXISTING LOAD 10 11 EXISTING LOAD 2011 B 12 13 EXISTING LOAD 20/1 A 30/2 EXISTING LOAD 14 15 EXISTING LOAD 2011 B 16 17 EXISTING LOAD 20/1 A 30/2 EXISTING LOAD 18 19 EXISTING LOAD 2011 B 20 21 EXISTING LOAD 1511 A 1511 EXISTING LOAD 22 23 EXISTING LOAD 1511 B 1511 EXISTING LCAD 24 25 EXISTING LOAD 15/1 A 15/1 EXISTING LOAD 26 27 EXISTING LOAD 1511 B 15/1 EXISTING LOAD 28 29 EXISTING LOAD 30/2 A 15/1 EXISTING LOAD 30 31 B 15/1 EXISTING LOAD 32 33 A 20/1 SMOKE DETECTORS 34 35 B 36 37 A 38 39 B 40 41 A 42 PHASE LOAD PHASE A= KVA, PHASE B= KVA. LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS [] MAIN BKR SHUNT TRIP [] PANEL SKIRTS ❑ SURFACE ❑ RAINTIGHT NEMA 3R ENCLOSURE ❑ DOUBLE LUGS • SERVICE ENTRANCE LABEL ■ INTEGRAL TVSS ❑ FLUSH REMARKS: "" PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. BLACK WHITE BLACK WHITE BK WH RED BLACK WHITE SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED SASEMENT ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION G: UGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. 112 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. 16 III 1 N/A DAMPER CONNECTION ❑' NON -FUSED DISCONNECT STITCH o MAST, WEATHERHEAD EP TOGGLE TYPE MOTOR DISCONNECT SWTCH WITH THERMAL OVERLOADS X BRANCH CIRCUIT HOME RUN OD ARE ALARM SMOKE DETECTOR 120V OPERATED —.- 1E3 ELECTRICAL METER FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED - AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. i 1 TIMER OPERATED SWITCH — - — X ® THERMOSTAT PROVIDE NEW S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONNECT TO NEW BREAKERS. SEE PANEL //- SCHEDULE E ®ROOM 3 15E ® ROOM 2 DEMO EXISTING ELECTRICAL PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL BASEMENT PLAN 1'1EC14ANICAL i ELECTRICAL Co0RIDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH sDi 24" x 24" EXIST. ATTIC ACCESS PANEL COVERED IDECK pININC ROOM 13E1DROOM 1 CONNECT TO LOWER LEVEL SMOKE DETECTOR CIRCUIT 54TH 1 KITCHEN LI /INCA ROO1 -1 NORTH TO FURNACE DAR C,AR°ORT ROOF RECEIVED MAR 30 2012 PERMIT CENTER SEPARATE PERMITAND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 E NGINEERS. INS . N MIMil MIND ter, MUM 011 :p`.. .: /1110410 IMO 0810.03.1833 0 LL Q 4t- ti z ct w z z 0 V 0 z MPROVEMENTS 0 w 2 w/ w 0 z ce Nw L.L. AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1833