Loading...
HomeMy WebLinkAboutPermit D12-113 - RUSSELL 4-PLEX - UPGRADESRUSSELL 4 -PLEX 11602 42 AV S D12 -113 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400070 Address: 11602 42 AV S TUKW Suite No: Project Name: RUSSELL 4 -PLEX DEVELOPMENT PERMIT Permit Number: D12 -113 Issue Date: 04/05/2012 Permit Expires On: 10/02/2012 Owner: Name: RUSSELL WILLIAM P Address: 2801 S 128TH ST #100 , TUKWILA WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT D 11 -236. THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $53,581.00 Fees Collected: $503.80 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0021 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -113 Printed: 04 -05 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of arty other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature. Date: /c /fa Print Name: t This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done m conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All construction noise to be m compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. doc: IBC -7/10 D12 -113 Printed: 04 -05 -2012 7: All plumbing and gas piping work shall lOspected and approved under a separate pee issued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -113 Printed: 04 -05 -2012 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us AIM Building Permit No. t 1) -.--1 1 3 Mechanical Permit No. M OS Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Mop,- L 4 s Tenant Name: William P. Russell Property Owners Name: William P. Russell Mailing Address: 4201 S. 116th St. King Co Assessor's Tax No.: 3347400070 Suite Number: Floor: New Tenant: ❑ Yes J ..No Tukwila WA 98178 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South E -Mail Address: Sharyn.Parker @kingcounty.gov Day Telephone: (206) 296 -7437 Seattle WA 98108 City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H: Applications \Forms - Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORIV ION * 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 53,581 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 1,940 2nd Floor 1,075 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • PERMIT 'APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AG hit Signature: / Print Name: Timothy J. Fenlaso , SM Stempe lc hitects, PLLC Day Telephone: (206) 624 -2777 Date: M VOA. Se U� Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Fmms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bb Page 6 of 6 PLUMBING AND GAS PIPIN ' -RMIT INFORMATION — 206 -431 70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Day Telephone: Fax Number: Expiration ate: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'1 Building Cod Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas pipiti utlets ng installed and the quantity below: Fixture Type: Qty Fixture Type: J ty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler(per he Food -waste grinder, ommercial Floor Drain Shower, single head trap Lavatory ` h fountain Receptor, indirect waste Sinks Urinals Water . set Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater d/or vent Industrial treatment interceptor, in ` ' ' ing trap and vent, except '. , itchen type grease intercept Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair ,r alteration of wate .iping and/or water tre ent equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 ' : ckflow protective evice other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications \Forms - Applications On- Line\2009 Applications \1-2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cif of 'Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -01243 Initials: WER User ID: 1655 Payee: PAMELA K KUEHL (PHONE) Payment Date: 04/05/2012 Total Payment: 6,715.15 SET ID: 033012 SET NAME: KING COUNTY HOUSING AGAIN SET TRANSACT1ONS: Set Member Amount D12 -099 229.85 D12 -100 220.30 D12 -101 334.07 D12 -102 304.27 D12 -103 191.65 D12 -104 228.20 D12 -105 326.62 D12 -106 210.75 D12 -107 210.50 D12 -108 220.30 D12 -109 311.72 D12 -110 172.55 D12 -111 248.95 D12 -112 419.17 D12 -113 503.80 M12 -041 167.70 M12 -042 167.70 M12 -043 177.10 M12 -044 167.70 M12 -045 167.70 M12 -046 167.70 M12 -047 167.70 M12 -048 167.70 M12 -049 167.70 M12 -050 167.70 M12 -051 167.70 M12 -052 167.70 M12 -053 167.70 M12 -054 167.70 M12 -055 225.25 TnTAT, . 229.85 City of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: htty: //www, ci. tukwila. wa. us TRANSACTION LIST: Type Method Beecription • Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 6,715.15 6,715.15 Account Code Current Pmts BUILDING - RES MECHANICAL - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 640.237.114 TOTAL: 4,065.20 2,582.45 67.50 6,715.15 , • INSPECTION NO. • :INSPECTION RECORD Retain a copy with permit v,? 3 PERMIT NO. CITY .OF'.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12, (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: • • A Zi 5444 ._ .9 - 134 F" Type of Inspection: /-----/ Abe? L.- Address: 'l./492 qz /hi s Date Called: 5/-23-/7 Special Instructions: • • • . ggm Date Wanted:. a.m 55'5- 31x7 -y &Z2 p.-. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: l Lei /tai( - �- IppOJJ�*C� a) ad ; 4.:A<S -tAl 6-1-4 I - 14 .�� El SPECTION FEE RE IRED. Prior•'to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: y- z3 — /z. co V • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -113 PROJECT NAME: RUSSELL 4 -PLEX SITE ADDRESS: 11602 42 AV S X Original Plan Submittal Response to Correction Letter # DATE: 03 -30 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: r s� b-idding" T Division Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 5 Incomplete DUE DATE: 04 -03 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-01-12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip doc 2 -28 -02 Contractors or Tradespeople Prjier Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135931 DONALD, SHARYN Treasurer 09/01 /2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Landmark American Ins Co LHA135931 03/01/2012 03/01/2013 $1,000,000.00 03/06/2012 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/05/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 4EPARITip PERMIT REQUIRED FOR Kabhanic al ectrical Plumbing [Was Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Fig. E COPY Permit No. Pi'i review approval is subject to errors and omissions. t, ,) ;,a, of construction documents does not authorize .3! ion of any adopted code or ordinance. ce :pt fll 3provecl Fie ' py�;�,�_ r�s is acknowledged: By Date L//6 /1 z. City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 A-r vviL City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, international Fire Code, international Mechanical Code 33414000/0 1_EGAL DESCRIPTION: HILLMANS MEADOW GARDENS Div • 1 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: lNo Chance) V B NON SPRINKLERED BUILDING AREA No change to building footprint. Addition:. Remodel: Sound Insulation: DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. A1.0 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHEDULE 4 DETAILS 42.1 DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS MID LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M20 MAN FLOOR MECHANICAL PLANS AND DETAILS Ei,0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 9810S Ph: 206. 263. 9233 Fax: 206.2%. 0190 Contact: Sharyn Parker E- mall: SharynParkerekingcounty.gov ARCHITECT: 5M. Stemper Architects PLL.C. 4000 Deiridge Way BUJ, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -ma11: Jerryeamstemper.com melodysemetemper.com tim*emstemper.com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. Ma Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics,com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 31S. 0569 Fax: 206.318.0641 Contact: Chris Ager E -mail: ChrlaA+greenbuech.com ELECTRICAL ENINEER: Tree West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreewest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 98102 Fh: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenepbeenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. +1200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mall: JCornwelleJoneopayne.com RECEIVED MAR 3 0 2012 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (2D8) 824 -2777 • FAX (208) 824 -2973 0810.03.1838 TEMPE iwkl NGTON 2/24/11 i..� O 0 J Q z 0 i- z w i"- z 0 (9 z MPROVEMENTS 0 2 w ce w 0 z tL RESIDENTIAL AIRC AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1838 NOTES: L ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 020S0 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 1, EsED I' 001-1 LAUNDRY NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO &.00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. Z. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM - GLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND PETALS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM MILER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE S:00 AM. 4 AFTER 5 :00 Pit 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. UNIT A KI T CI•-li N LIVING F oori MAIN FLOOR PLAN �1� 114 " =1' L Li 3 L1VING ROOM T. 1 ITLL L.__.__._r 1 L PLAN KEYNOTES cDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET A2.I `./ O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REP. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL. OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/A22 FOR DETAIL. 0 COORDINATE WALL GRILL WIN MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING: AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. NE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. �EDOOM UN IT F ROOM 2 A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION LEGEND ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES T FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED WALL GRILL NOT USED NOT USED REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 30 Z012 PERMIT CENTER SD INSTALL BATTERY OPERATED SMOKE DETECTORS I IGAS NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1 838 2/24/11 0 0 T 0 I- T w z Z 0 0 T MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1838 WINDOW TYPES SINGLE HUNG 2 CASEMENT 3 SLIDER/ FIXED/ SLIDER 4 CASEMENT/ FIXED WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A BEDROOM 1 2 2' -10" x 3' -10" STAIN/PAINT SAFETY GLAZING REQUIRED Y 1/42.0 _ B BEDROOM 1 I 5' -10" x 1' -I0" STAIN/PAINT _ I/42.0 C BEDROOM 2 I 5' -10" x 1' -I0" STAIN/PAINT I/42.0 BEDROOM 2 2 2' -10" x 3' -10" STAIN/PAINT Y I/42.0 E KITCHEN I 2' -0" x 2' -10" STAIN/PAINT 1/42.0 F LAUNDRY ROOM 3 5' -4" x 4' -4" STAIN/PAINT SAFETY GLAZING REQUIRED I /42.0 G LIVING ROOM 4 4' -4" x 3' -10" STAIN/PAINT SAFETY GLAZING REQUIRED 1/42.0 (E) = EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR 514EATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO PIN BEHIND (E) LAN BACKER ROP 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FN BEHIND (E) LAN WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING 0 WINDOW HEAD /rt I� 1-7d WINDOW JAMB WINDOW SILL (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATCH WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT 1X WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IX WOOD LEDGER SEALANT BED (E) GWB STUCCO — WINDOW DETAIL SET 3 " =1' -0" TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. . REVIEWED FOR CODE COMPLIANCE y APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 3 0 2012 PERMIT CENTER btx-113 • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 F E.GISTEKED ' HITECT '.COTT STATE OF 0810.03.1838 2/24/11 MPROVEMENTS 0 w w w 0 z LL ct Q I-- w IY AIP NUMBER 5 -53 -0058 -043 z 0 Lil z_ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1838 DOOR TYPES O ,4 FLUSH SCUJ EXTERIOR SINGLE LEAF W/ WAGON WHEEL STORM W/ SAFETY GLAZING AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -S" STAIN/STAIN I-IW -I 1 626 DK -2 LOCK -1 1/42.1 2 LAUNDRY ROOM A 2' -S" x 6' -S" STAIN/STAIN WW-1 / 626 DK -2 LOCK -1 1/42.1 3 ENTRY B 3' -0" x 6' -S" 1/42.1 4 LAUNDRY ROOM B 2' -S" x 6' -8" 1/42.1 BACKER ROD AND SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING NSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DooR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE 0 2" MIN. DOOR JAMB DOOR SILL STUCCO - DOOR DETAIL SET (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL SEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 04 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 30 2012 PERMITCENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (208) 824 -2973 !1, REGISTERED HfTE:CT O" GATT 9 iTFMPE. STATE QE . HINGTON• 0810.03.1838 2/24/11 0 ._I z 0 z W z O U 0 z MPROVEMENTS >- 0 W 2 W W co 0 z U OC H z AIP NUMBER 5 -53 -0058 -043 0 H 0 z_ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1838 ■ (E) STUCCO TO REMAIN BACKER ROD 4 SEALANT PRE - PRIMED, GALV 51-1EET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR PLYWOOD (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (PT) AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: -� MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS • 16" O.0 5/8" GM- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12 "X16" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 1 1/2" = 1' - 0" EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS V SOFFIT DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING TO LEDGER. COAT" x 1" WD BLOCKING W/ ADHESIVE AND INSERT AT (E) GLUES PANEL EDGE. PROVIDE FINISH -GRADE PAINTABLE GWB EDGE AND CAULK JOINT DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS 16 ", PROVIDE 2x2 SOFFIT FRAMING 1 16" OC. 2x2 CONT. NAILER . 3" Gus- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 1 1 /2" = 1' - 0" MATCH EXIST. SOFFIT HT. RECEIVED MAR 30 2012 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A;; HITE:CT COTT STATE OF 0810.03.1838 2/24/11 TEMPE HINCTON i- Ct 0 J � Q � Z O 2 W ce Z W DC � W 0 Z Z U 0 0 < W 0 W MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 Z 0 I- 0 t!) J I— LiJ U) DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1838 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 4 XX ABBE OR XX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y - X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. SYMBOL $G X XX Imo- DN I + DN I-uPI + f + �-' 0 L.� f';'] EQUIP ID#� R T NG 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) SA LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM N0. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 • 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1838 602 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1506.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 0. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2. QF = 45 / (1 X 1/2) = 90 CFM P0 0 4 49 09 A r9:: RECEIVED MAR 3 0 2012 PERMIT CENTER D I4,17 <13 EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Lability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE,. WA 98108 (20e) 024 -0777 • FAX (20e) ee4 -8973 THE GREENBUSCH GROUP, INC AUDIO VIDEO YEEIMROAL ENOFEDa19 ,000 DET SMIEr DUDE 201 SFRNE. 01100110 (208) 379 -0509 (200) 378 -0041 FAX 0810.03.1838 Ir- Ce 0 0 cc J z 0 z E w z KING COUNTY cn z w w 0 ce 0 >- 0 w w w 0) 0 z LL U c AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1838 SEE BEDROOM 2 TYP ALL WALL GRILLES SOFFIT BY OTHERS ECTA 25 BV -1 LOCATED IN CLOSET SOFFIT BEDROOM 140 111,114•w 25 ', QQ=1 90 BATH SEE SEE UNIT A MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE CLOSET SOFFIT COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE KITCHEN LIVING ROOM NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE Jr DUCT PER PLAN DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL WALL CAP INSTALLATION DETAIL FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE INSTALLATION DETAIL NONE RECEIVED MAR 3 0 2012 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUT.I'I 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2978 THE GREENBUSCH GROUP, INC ))) AI1010 VIDEO i YE 201 013. U101�11N0 1100 1�f 81AiET 8E1E 81 ?ui11IE, N 0111 (200) 378 -0889 (201) 378-0041 FAX 0810.03.1838 KING COUNTY INTERNATIONAL AIRPORT MPROVEMENTS w w LL! 0) 0 z F- u_ F- Z w C w AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1838 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. O HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810,03.1838 SYMBOL 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE AIC, 100 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 16 15 CKT LOAD DESCRIPTION TYPE KVA NP PHASE ALP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD SMOKE DETECTOR — . 40/2 A B 30/2 TIMER OPERATED SWITCH 120 EXISTING LOAD 2 4 5 EXISTING LOAD X 20/2 A 30/2 EXISTING LOAD 6 7 9 11 SPACE SPACE SPACE PHASE LOAD PHASE A= KVA PHASE B= 20/1 15/1 #VALUE! A KVA. B B 1 15/1 20/1** REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH EXISTING LOAD BLENDING UNIT 6 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN.LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS E] RAINTIGHT NEMA -3R ENCLOSURE ❑ DOUBLE LUGS MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS SERVICE ENTRANCE LABEL ❑ INTEGRAL SURFACE FLUSH • • ❑ TVSS ❑ REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION G UGHIING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 16 15 III 1 0 DAMPER CONNECTION 1 ' NON -FUSED DISCONNECT SWITCH c MAST, WEATHERHEAD EP TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN QD SMOKE DETECTOR — . c ELECTRICAL METER 1,2 - TIMER OPERATED SWITCH 120 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. ® THERMOSTAT — - — X X MEC IANICAL 1 ELECTRICAL COO INATIOil ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH 5E D ROOM 2 BAT -I LAUNDRY KITGI -TEN LIVING ROOM 0810.13.1838 UNIT A EXISTING ELECTRICAL PANEL KITGI -TEN LIVING ROOM MAIN FLOOR PLAN 1/4" = 1' 1541-1-1 5EDIROOM p« - -113 NO0 RECEIVED MAR 3 0 2012 PERMITCEENTER SEPARATE 4 PERMIT AND APPROVAI. REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (206) 624 -2973 !NOINdEl1S. INO MI IMAM iNe MER. SUMO NI TAM" rw► NORM TOlRI1MM OMB A O00 NM IMP YPOEM 0810.03.1838 0 J 0 z w z z O U 0 z AIP NUMBER MPROVEMENTS 0 w 2 w w 0 z u_ UM/ L.L.. C 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1838 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT T14i5 RESIDENCE. TWE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. >5 L EDROGI l 2 f-- KITCHEN 1 fry NOTE: NTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON TI-4E SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. B. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 1 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SWEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMLIfi1 POWER OUTAGE IS EIGHT I•IOUI S POWER MUST BE PROVIDED AT RESIDENCE BEFORE &.00 AM. 1 AFTER 5:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR TWE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19 EXISTING WINDOW COVERINGS MUST BE REINSTALLED 014 TWE SAME DAY AS COMPLETION OP WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. UNIT A AUNOF -zrr EDF OM 2 # :I ; CH:EN 1 L11'lNG HOC ,)1'1 1 UNIT D Le.,ATH 1 1 Li 5 D I OOM 3 L IVINC 1 KITCHEN MAIN FLOOR PLAN 1/4" = 1' UNIT 5 D1� 113 PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 0 DEMOLISH EXISTING DOOR(S), FRAME, CASH , AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET A2.1 ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL. �BLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED N SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL. AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. REVIEWED FOR CODE COMPLIANCE APPROVED LEGEND APR 0 4 2012 City of rukwila BAIT DING DIVISION A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION f i ACOUSTICAL WNDOW NOT USED EXTERIOR STORM DOOR DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. 42.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT U5E0 ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED !il GAS WALL GRILL RECEIVED MAR 3 0 2012 P T CENTER NOT USED ATTIC INSULATION INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 824 -2873 4220 REGISTERED A' HITECT SCOTT STATE OF 0810.03.1839 TEMPE SHINGTON 2/24/11 0 ct rr� z 0 Q z Ice w 1-- z 0 Y 0 z MPROVEMENTS 0 w 2 w ce w 0) 0 z LL C.) ittC w AIP NUMBER 5 -53- 0058 -043 z 0 C0 LLI DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1839 WINDOW TYPES 1 FIXED W/ OBSCURE SAFETY GLAZING 2 CASEMENT 2'-0" MIN. 3 4 SLIDER/ FIXED /SLIDER CASEMENT/ FIXED WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 1 1' -0" x 6' -6" STAIN/PAINT 1/42.0 B LIVING ROOM 4 4' -4" x 3' -10" STAIN/PAINT 1 /A2.0 C BEDROOM 1 3 5' -10" x I' -10" STAIN/FAINT CUT SILL TO 40" AM FOR EGRESS (E) HT. 55" y 1/42.0 D BEDROOM 2 3 5' -I0" x I' -10" STAIN/PAINT 1/42.0 E BEDROOM 2 2 2' -10" x 3' -I0" STAIN/PAINT y 1/42.0 (E) • EXISTING (E) STUCCO (E) STUCCO U■DERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. INFORCEMENT. STUCCO DRIP SCREED PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD E SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LAN WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING WINDOW HEAD "141-`tti [n] \ 11 WINDOW JAMB 0 WINDOW SILL (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATC WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT (E) GU WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROP 4 SEALANT IX WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" WD. SILL - STAN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM 1X WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3" = 1' - 0" TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING I3 INDICATED, BUT NOT SCHEDULED IN SECTION 05500 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. D.A3 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 ' . City of Tukwila BUILDING DIVISION RECEIVED MAR 3 0 2012 PERMIT CENTER • S.M,STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 0810.03.1839 2/24/11 TEMPE HINGTON 0 Cl. J z O z W F- z z O U 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 F— C7 z DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN A A, LB &J H WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1839 DOOR TYPES O FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY A 3' -0" x 6' -S" STAIN/STAIN 14W -1 1 626 DK -2 LOCK -I 1/A2.1 2 ENTRY B 3' -0" x 6' -S" 1 /A2.1 (E) STUCCO TO REMAIN BACKER ROD AND SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCI- IEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB EXISTING FLOOR STRUCTURE 0 DOOR SILL STUCCO - DOOR DETAIL SET (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM 51-1IM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE 3 "= 1' -0" TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCI- IEDULED IN SECTION 05500 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 30 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 0810.03.1839 2/24/11 O 0_ J z 0 Q z LL1 z z 0 0 00 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 I- 0 Lil z_ H GI) DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1839 (E) STUCCO TO REMAIN BACKER ROD 4 SEALANT PRE-PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH: PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 = 11 -0 SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DuCTS- REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS •1 I6 ", INSTALL 2X4 STUDS • 16" OG. 5/8" GWB- PANT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12 "X16" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 11/2 " =1' -0" EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS t REVIEWED FOR I CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING TO LEDGER COAT )Q' x I" WD BLOCKING W/ z.- ADHESIVE AND INSERT AT (E) GU PANEL EDGE. SOFFIT DETAIL PROVIDE FINISH -GRADE PAINTABLE GWB EDGE AND CAULK JOINT DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS 16 ", PROVIDE 2x2 SOFFIT FRAMING • 16" O.C. 2x2 CONT. NAILER %8" GUS- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 11/2 " =1' -0" MATCH EXIST. SOFFIT HT. RECEIVED MAR 30 2012 PERMIT CENTER 113 • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (208) 824 -2973 0810.03.1839 2/24/11 TEMP HINGTON 0 0 oc -J <C z w O � � w Q ce w Z Z � gll- Z U O 0 < 0 J Z Q Z w 0 U) w MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 z L1.1 LLI DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1839 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP H VAC HW H WC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL Q DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE +- DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y CD EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO. PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL SG + D N + uPI + s + f + $ ILO EQUIP IDR � x NG • 0 D'a DN UP DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SA RA /EA SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08° WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1839 597 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 4a &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM r5 RECEIVED MAR 3 0 2112 PERMIT CENTER SEPARATE 4 PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 024 -2777 • FAX (600) 624 -2973 THE GREENBUSCH GROUP, INC ))) 3195T SUR 201 5ilif1LF. 15 16119 (206) 375-0566 (206) 375 -0541 FAX 0810.03.1839 KING COUNTY INTERNATIONAL AIRPORT z w w 0 a 0 ce w w w 0 z V Q 0 AIP NUMBER 5 -53 -0058 -043 z 0 1-- z_ J LLI DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1839 MAIN FLOOR MECHANICAL PLAN 1 .1 SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE UNIT E3 SOFFI T NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. DUCT PER PLAN FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED MAR 30 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Prafamional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 --2477 • FAX (808) 824 -2973 THE GREENBUSCH GROUP, INC ))) AUDIO 110E0 IECIWIOM. OIG9 ID 19DD 1�r 91REl EIEIE 401 WISE. W. 18119 (208) 378 -0889 (408) 378 -0941 FAX 0810.03.1839 KING COUNTY INTERNATIONAL AIRPORT z w w 0 2 0 w w w 0 z u_ U ce Z w a C U-1 AIP NUMBER 5- 53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID GROUP M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, DO, MM & JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1839 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810.03.1839 6Y1130L 10,000 1201240 VOLT, 1 PHASE, 3 WIRE, BKR G RESIDENCE AIC, 100 AMP with MAIN BRANCH CICUIT WRING AND AND EQUIP R INDICATED ON PLANS. D (WIRING ANDIRCONDUIIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. 16 15 CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD SMOKE DETECTOR -.- 40/2 A B 30/2 TIMER OPERATED SWITCH 120 EXISTING LOAD 2 4 5 EXISTING LOAD THERMOSTAT - - - 2011 A 30/2 EXISTING LOAD 6 7 9 11 SPACE SPACE BLENDING UNIT PHASE LOAD PHASE A= KVA PHASE B= 1511 15/1 20/1** #VALUEI A KVA. B B 20/1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL AL) 2 - DISCONNECT SWITCH EXISTING LOAD 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN.LQAD KVA AMP COMPUTED LOAD KVA AMP ISOLATED GROUND BUS ❑ FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE RAINTIGHT NEMA-3R ENCLOSURE ❑ DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH 0 REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM, ELECTRICAL L C ND 811m UESCRIFTION 6Y1130L DESCRIFTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION G UGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CICUIT WRING AND AND EQUIP R INDICATED ON PLANS. D (WIRING ANDIRCONDUIIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. 16 15 I I I I 1 15 DAMPER CONNECTION 0' NON -FUSED DISCONNECT SWITCH ® MAST, WEATHERHEAD ❑S ' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN j SMOKE DETECTOR -.- X ELECTRICAL METER 1,2 - TIMER OPERATED SWITCH 120 1 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. ® THERMOSTAT - - - X 1 t1EC1-IANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL AL) 2 - DISCONNECT SWITCH KITCHEN LIVING 1ROOM 0810.13.1839 UNIT B EXISTING ELECTRICAL PANEL 15E1DIROOM 1 SE 1D iROOM 2 MP /11 MAIN FLOOR PLAN 114" = 1' b1)=113 NORTH RECEIVED MAR 3 0 2012 PERMITCENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1839 0 0 s -J z 0 i- LL w I-- z KING COUNTY MPROVEMENTS a w w z I- ce J w w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1839 2 i L. 3L.a F'COI" i (--/-/r.-- • r r UNIT 4 5,411 -1 ROOT 2 \\ / 1 K T CHEN I ( LAWN —t vii r:T / / I / N TCHEN / / / / /L I' ✓II�IC -� / ROOM / / KITCHEN \ \ \ 1 IVING FC'OM I EDROONI 3 LIVING'\ ,OOi i \ I r E ROOM 0 BATH 2 EXIST. ROOF LINE UNIT 3 MAIN FLOOR AND ROOF PLAN 1/4" = 1' NOTE: I. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02051. NOTE: INTERIOR TRIM TO 13E FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT NE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOM5. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOUJS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL MD REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 5 :00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WOW AREAS SHALL BE BROOM - CLEANED AT NE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL MD MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WIN (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WIN NE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. HELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY NE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE MD COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH NE ADJACENT (E) FNISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDED BEFORE &00 AM. 4 AFTER 5:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER UJOR( REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY NAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, MD WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WIN MECHANICAL. 15. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. BEDROOM IS x 24" EXIST. ATTIC ACCESS PANEL KITCHEN DINING ROOM BEDROOM 2 LIVING ROOM O A UPPER FLOOR PLAN 1/4" = 1' \ \ N \ N Y I F I IC - - --1 I" --Ls I I - -_I I I I - -J I I J 15" x 24° EXIST. ATTIC ACCESS PANEL J LuJ L _J r� IIr7II I / / / / / / / / n I I I I I II I II II /-71 1- - -- i / \ / \ / \ / \ / / NO INSULATION / n I L_ ATTIC PLAN 1/4" = 1' REQUIRED - N \ A. NORTH ELEVATION B. EAST ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 420 0 DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET A2.1 �DEMOLISH R EXTERIOR WALL ASEMBLY AS EQUIED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH MECHANICAL. OBLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. OCOORDINATE CEILING GRILL WITH MECHANICAL. 0 INSTALL VENT BAFFLE(5) AT EXISTING RIDGE VENT(5) IN ATTIC, REF. 4/A22 FOR DETAIL. OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/422 FOR DETAIL 0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. NE CONTRACTOR MD THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. SOUTH ELEVATION LEGEND J J ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL EXISTING KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE D. WEST ELEVATION D lam- I 13 NOT USED NOT USED NOT USED RECEIVED MAR 302012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION SD INSTALL BATTERY OPERATED SMOKE DETECTORS I KITCHEN EXHAUST BAFFLE GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98100 (206) 621-2777 • FAX (206) 624 -2973 COTT TEMPE STATE OF SHINGTOP 0810.03.1840 2/24/11 0 0 ce SIC —J ctt z 0 z W z KING COUNTY AIP NUMBER 5 -53- 0058 -043 z 0 z C1a J I•— LLJ CJ� DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1840 WINDOW TYPES SINGLE WING 2 SLIDER/ FIXED/SLIDER N 3 CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 6' -0" x 4' -0" STAIN/PAINT - I /422) 5 LIVING ROOM I 3' -2" x 3' -10" STAIN/PAINT 1/42.0 C LIVING ROOM I 3' -2" x 3' -10" STAIN/PAINT 1/A2.0 D DINING ROOM I 3' -2" x 3' -10" STAIN/PAINT I /A2.0 E DINING ROOM 2 6' -6" x 2' -6" STAIN/PAINT 1/42.0 F KITCI -IEN I 3' -6" x 4' -0" STAIN/PAINT I /A2.0 G BEDROOM 1 I 2' -4" x 5' -5" STAIN/PAINT I/42.0 N BEDROOM 1 I 3' -4" x 5' -5" STAIN/PAINT Y 1/42.0 I BEDROOM 2 I 3' -4" x 5' -5" STAIN/PAINT y 1/42.0 J BEDROOM 2 I 2' -4" x 3' -4" STAIN/PAINT 1/42.0 K BEDROOM 3 3 2' -4" x 4' -0" STAIN/PAINT Y 1/42.0 L CORRIDOR (ABOVE STAIRS) I 2' -S" x 3' -2" STAIN/PAINT 1/42.0 (E) = EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH BACKER ROD 1 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING WINDOW HEAD �I 11 II WINDOW JAMB 0 WINDOW SILL (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MAT WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT 1X WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM 1X WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3 " =1' -0" TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. b 1)- REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 ' City of Tukwila BUILDING DIVISION RECEIVED MAR 30 2012 PERMIT CENTER l3 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT T.EMPE STATE OF f . HINGTOK'' 0810.03.1840 2/24/11 0 0 J z 0 ,C z W I- z z 0 0 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE z 0 C9 LLI z 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1840 DOOR TYPES ®® O ,A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY A 2' -8" x 6' -6" STAIN /STAIN HW -1 / 613 DK -I LOCK -I 1/42.1 2 ENTRY B 2' -8" x 6' -6" I /A2.1 INSTALL SPRING LOADED HINGES TO DOOR I PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP WI BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) STUCCO TO REMAIN BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE DOOR HEAD KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND 2" MN. WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE 0 DOOR JAMB DOOR SILL (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ GATT INSULATION DOOR PER SCHEDULE STUCCO - DOOR DETAIL SET 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL SEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. Dim REVIEWED FOR 'CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 30 2012 PERMITCENTER 13 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • PAX (208) 824 -2973 REGISTERED 'NITECT COTT WTEMPE' STATE OF ! 'SHINGTOI 0810.03.1840 2/24/11 Ct O 0 ce J z O z w z 0 0 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 I-- 0 z_ C%) LLI I-- F- w DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1840 (E) STUCCO TO REMAIN SACKER ROD I SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR WI ACOUSTICAL DAMPING COMPOUND. SET N MASTIC AT EXTERIOR TRIM. PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (PT.) AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" / PREMANUFACJUREID ROOF BAFFLE (LE AN- MODEL 634) \ > EXIST G DUCTWORK EAL 41. NAILS WIN ROOF CEMNT SEAL SHINGLES TO ROOF CAP ON TOP AND SIDES NOTE: I PREMANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURE'S INSTRUCTIONS. KITCHEN EXHAUST BAFFLE 1 1/2" = 1' - 0" (E) 2X10.16 "0.C. (E) GWB BLENDING AIR UNIT ACCESS PANEL 1 1/2" = 1' - 0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL DISPLACE (E) INSULATION TO FACILITATE INSTALLATION OF MECHANICAL UNIT, DUCTS AND ACCESS HATCH CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL INSULATION STOP AT PERIMETER OF ACCESS HATCH OPENING, 4 SIDES - 2x WD BLOCKING EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION RIDGE VENT BAFFLE 6" MN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. 1 1/2 "= 1' -0" (E) ATTIC DUCT CHDASE ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS 116" O:C. J -METAL EDGE AND CAULK JOINT E SOFFIT DETAIL DEMOLISH (E) GWB NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5 /S" GWB- PAINT TO MATCH (E) TEXTURE 4 PERMIT CENTER COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL RECEIVED MAR 3 0 2012 (E) WD FRAME WALL ASSEMBLY 11/2 " =1' -0" 3 • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1840 2/24/11 TEMPE HINGTON i- ce 0 0 J � z w O � w Z w Z z � gll- Z U 0 Ce U < 0 J Z Q z w w MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z O C7 z_ 5 I-- DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1840 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW H WC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB WI WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANI ZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL SG-X ABBE. + f + } Ea.% CD 0 EQUIP IDR CD. NG 171 • 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) SA LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, Z 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" CEILING DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, Z 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1840 1148 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE [NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = OR / ( &EGR X F) QR = (FROM TABLE 403.8.1) &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2. QF = 45 / (1 X 1 /2) = 90 CFM bl� 11 3 RECEIVED MAR 3 0 2012 PERMIT CENTER SEPARATE 4 PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (201) E24-2973 THE GREENBUSCH GROUP, INC ))) AUDIO i IIE>CHWIGL Q1011:13111 1900 ll�l MU 2111101 9EMiIL M 01110 (206) 378 -0610 (100) 378 -0041 FAX 0810.03.1840 NTERNATIONAL AIRPORT z 0 U Z MPROVEMENTS >- 0 w 2 w w Go O z LL U ce a AIP NUMBER 5 -53- 0058 -043 z 0 1-- z w LLI co DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1840 BEDROOM BEDROOM 2 KITCHEN DINING ROOM TYP TYP SEE M2.0 TYP ALL CEILING GRILLES LIVING ROOM UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS ATTIC NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE UNIT C NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN ATTIC. USE EXISTING ATTIC ACCESS HATCH FOR MAINTENANCE AND ELECTRICAL ACCESS. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWNGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL 3 NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER 2. SEE PLANS FOR VOLUME DAMPER LOC 3. CEILING SUPPLY INSTALLATION SHOWN, FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE MANUFACTURER'S WRITTEN INSTRUCTIONS. AI1ONS. RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL 4 NONE l SEPARA'TE PERMITAND APPROVAL REQUIRED RECEIVED MAR 30 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 08100 (206) 6248777 • FAX (208) 824 -2273 THE GREENBUSCH GROUP, INC ))) orw wow Mom s MEC MNOAL UIGI�Eil8110 1Y00 1� 311W SUM 801 9WYWT11E M 118119 (208) 376- 0869 (208) 378-0141 FAX 0810.03.1840 GO F- z w w Ce O O a -J < w - w Z IJU Z gll- Z 0 0 aC 0 J z Q 1- z w a C/) w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1840 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES �1 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 03 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. 04 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. PANEL MP LOCATION: SERVING: 0810.03.1840 SYMBOL 10,000 120/240 VOLT, 1 PHASE, 3 VARE, BKR DESCRIPTION RESIDENCE AIC, 100 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 16 111111 CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD rE] ELECTRICAL METER 40/2 A B 30/2 SWITCHES (ON, TIMER) 120 EXISTING LOAD 2 4 5 7 9 11 EXISTING LOAD EXISTING LOAD EXISTING LOAD SPACE PHASE LOAD PHASE A= #VALUE! KVA, PHASE B74 20/1 20/1 20/1 #VALUEI A A KVA. B B 20/2 2011 ** 2011 ** EXISTING LOAD BLENOINGUNIT SMOKE DETECTORS 6 8 10 12 LOAD TYPE L R M H WH REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS RAINTIGHT NEMA -3R ENCLOSURE ❑ DOUBLE LUGS MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS fl FLUSH • • REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTINGSYSTE]IA. 15/1 r1 L -0 0 BLACK BLACK BLACK SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION LIGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 16 111111 C DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH ® MAST, WEATHERHEAD SD' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS 1 BRANCH CIRCUIT HOME RUN ( 0 FIRE ALARM SMOKE DETECTOR 120V OPERATED -�- rE] ELECTRICAL METER X FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED 1,2 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. SWITCHES (ON, TIMER) 120 TIMER OPERATED SWITCH - - - X O THERMOSTAT MEcI- IAN,ICIAL i ELECTRICAL cooRD UNITioil ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH <ITCEN ®ININC1 IR001-f 0810.13.1840 UNIT C ELECTRICAL PANEL IS LOCATED IN HALLWAY ON MAIN LEVEL NEAR THE STAIRWELL LYING ROOM UNIT C RECEIVED MAR 3 0 2012 PERMIT CENTER SEPARATE 4 PERMIT AND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Prafeasional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (208) 624 -2973 0810.03.1840 0 0_ Ce J z 0 z w F- z z 0 0 z MPROVEMENTS 0 w 2 conw w 0 z u_ L.L ® AIP NUMBER 5 -53 -0058 -043 z 0 F- 0 z W DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1840 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK MD WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02050 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT TI-115 RESIDENCE. REFER TO SECTION 01011 AND 02051 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. >5 F 2 BED P-70011 { r J UNIT A MAIN FLOOR PLAN 1/4" = 1' NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES I. CONTRACTOR TO PROTECT GONERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVNG, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMt l POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 All. 4 AFTER 3:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. LIVING ROOM 1 LIVING: ROOM -L 1 A EAT14 PLAN KEYNOTES 0 PEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 O �.. DEMOLIH EXISTING DOOR(S), FRME, CASIN, AND THOLD. INTALL NEW EXTERIOR DOOR, FRAME, CAING, AND STOM DOOR. REF. DOOR SCHEDULE ON SHEET A2.1 3 O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL. OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED N SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED 4 CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA REF. MECH. FOR INSTALLATION DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. NE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. F UNIT T Ia 7/ 2 LEGEND 1)Ht3 A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION 1" 1 ACOUSTICAL WINDOW EL') NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED 11111 WALL GRILL !GAS NOT USED NOT USED ECEIVED MAR 3 0 2012 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 90100 (206) 624 -2777 • FAX (206) 624-2973 REGISTERED HITECT 0810.03.1841 2/24/11 O CL J Z 0 Ct z w z z 0 0 C7 z MPROVEMENTS D ctW W W 0 F— Z LL U H D co ct AIP NUMBER 5 -53 -0058 -043 z O I— Z DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1841 WINDOW TYPES SINGLE HUNG 2'L 0" MT. 2 SLIDER/ FIXED /SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 5' -4" x 4' -4" STAIN/PAINT SAFETY GLAZING REQUIRED 1/42.0 B KITCHEN I 2' -0" x 2' -10" STAIN/PAINT I /A2.0 C BEDROOM I I 2' -10" x 3' -10" STAIN/PAINT I /42.0 D BEDROOM I 2 5' -10" x 1' -10" STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 51" Y I /42.0 E BEDROOM 2 2 5' -10" x 1' -10" STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 51" y 1 /A2.0 F BEDROOM 3 1 2' -10" x 2' -10" STAIN/PAINT VA2.0 G BEDROOM 3 2 5' -9" x 2' -0" STAIN/PAINT SAFETY GLAZING REQUIRED Y 1/A2.0 (E) = EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADI- IERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD t SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH (E) GWB (E) WP. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATCH (E) WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT WINDOW HEAD BACKER ROD I SEALANT ACOUSTICAL WINDOW ASSEMBLY WINDOW JAMB ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING L • \1if I ■Nol m`. WINDOW SILL (E) GWB WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SACKER ROD 4 SEALANT IX WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" IUD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IX WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3" = 1' - 0" TYPICAL WINDOW SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 05800 ALL UNLAMINATEP GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 302012 PERMIT CENTER tl3 S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED •'HITECT COTT .EMPE; STATE OF r HINGTON 0810.03.1841 2/24/11 F- 0 ce J z 0 z w F- z z 0 0 00 MPROVEMENTS >- 0 w 2 w w 0 z U- 0 aC J H z w 0 w ce AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1841 DOOR TYPES ESP 0 A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -S" STAIN /STAIN HW -1 / 626 DK -2 LOCK -I 1/A2.1 2 ENTRY 8 3' -0" x 6' -S" 1 /A2.1 (E) STUCCO TO REMAIN BACKER ROD AND SEALANT PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MN. (E) STUCCO TO REMAIN WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEAT4ER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR FATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE 0 DOOR JAMB _7E1_4 DOOR SILL (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE STUCCO - DOOR DETAIL SET 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO 8E TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH NE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING POOR OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 04 2012 City of Tukwila BUILDING DIVISION RECEIVED MAR 30 2012 PERMITCENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (208) 824 -2973 REGISTERED :HIITE:CT , Mir( COTT STATE OF 0810.03.1841 2/24/11 O 0 J z 0 i- < w z z O U Ca z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 F- z I-- W DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1841 ATTACH 2x3 LEDGER TO EXIST. DE (E) STUCCO To REMAIN (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING BACKER ROD 4 SEALANT PRE - PRIMED, GALS SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO SE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT NTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET N MASTIC AT EXTERIOR TRIM. PRE - PRIMED, GALS SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 =1 -0 SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECI4 UNIT AND DUCTS- REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHEEZE WIDTH OF SOFFIT EXCEEDS ► �„ C4 \ ".'4112"--- J 16 ", INSTALL 2X4 STUDS a 16" O:C. EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS S /8" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12"X16" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 11/2 " =1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 4 2012 City of Tukwila BUILDING DIVISION ATTACH SOFFIT FRAMING TO LEDGER. COAT i5" x 1" WD BLOCKING W/ ADHESIVE AND INSERT AT (E) GUJI 3 PANEL EDGE. PROVIDE FINISH -GRADE PAINTABLE -MS EDGE AND CAULK JOINT SOFFIT DETAIL 1 1/2" = 1' - 0" DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS I6 ", PROVIDE 2x2 SOFFIT FRAMING 0 16" O.C. 2x2 CONT. NAILER 811" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. MATCH EXIST. SOFFIT HT. RECEIVED MAR 3 0 2012 PERMITCENTER Arm ti ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (208) 824 -2973 REGISTERED A. HITEC( COTT EM.PE.. STATE OF r - HINGTON' 0810.03.1841 2/24/11 0 0 J 0 � o z W 0 W Q ct Z W Ct W Q Z LL 0 0 U < U —I Z � Z W 0 W cc MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03 1841 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTUH CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WI TI-I WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX OR X 0 X/Y - DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -O" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL $ XX ABBR UPI 4. f f ji 4- + f + [■I I>< -el- EQUIP ID °;Q.._ OR (R NG • 3 0 D"4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT VD RA /EA RG SA SA RA /EA SD DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: AIDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: AIDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1841 875 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) ¢a &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1 /2 QF = 45 / (1 X 1 /2) = 90 CFM pia --113 RECEIVED MAR 30 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FIX (206) 684 -6673 THE GREENBUSCH GROUP, INC ))) 08IO WED 6 MEI9CNOAL DOWERING 190D 1�l ME 9011E 901 2E6114 96 00110 (206) 376 -0606 (206) 376 -0041 FAX 0810.03.1841 KING COUNTY INTERNATIONAL AIRPORT U) F- z w w 0 0_ 0 0 w w w U) O z F- U- 0 -J 0 F- z w U) w AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1841 SEE SOFFIT BY OTHERS 7 "O 4°0 * I p /BEDROOM UNIT D SOFFIT BY OTHERS BSz1 25 BEDROOM 6 "0 2 SEE KITCHEN LAUNDRY MAIN FLOOR MECHANICAL PLAN BATH 4 "0 8"0 4, 165 SEE u') n TYP ALL SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE SOFFIT COORDINATE ACCESS HATCH FOR ELECTRIC AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE NORTH WALL GRILLES TYP TYP BEDROOM 3 r LIVING ROOM C� SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUT11NG AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL f).- 113 SEPARATE PERMIT OVA REQUIRED RECEIVED MAR 3 0 2012 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A ProfaaaLOEal Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 864 -2777 • FAX (206) 6E4 -8973 THE GREENBUSCH GROUP, INC ))) 1O r NoAu0 • i r e 201 9N081. lo2. i01110 (206) 378 -0869 (206) 378-0541 FAX 0810.03.1841 KING COUNTY INTERNATIONAL AIRPORT PROVEMENTS AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1841 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8 :00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE UMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE. NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. O HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810.03.1841 SYM801.. 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE MC, 100 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 *C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. 16 15 CKT LOAD DESCRIPTION TYPE KVA A/P PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD SMOKE DETECTOR -■- 40/2 A B 3012 TIMER OPERATED SWITCH 120 EXISTING LOAD 2 4 5 EXISTING LOAD THERMOSTAT - - - 30/2 A ■ 20/1 EXISTING LOAD 6 7 9 11 SPACE PHASE LOAD PHASE A= KVA, PHASE B= 20/2 #VALUE± A KVA. B B 15/1 15/1 20/1" REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL All) 2 - DISCONNECT SWITCH EXISTING LOAD BLENDING UNIT 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP El ISOLATED GROUND BUS ❑ FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ RAINTIGHT NEMA -3R ENCLOSURE ❑ DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL ❑ PANEL SKIRTS ❑ SURFACE INTEGRAL TVSS Q FLUSH • REMARKS: ** PROVIDE NEW BREAKER TO MATCH FISTING SYSTEM. ELECTRICAL LEGEND SYMBOL DESCRIPTION SYM801.. DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION G UGHIING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 *C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. 16 15 I I I I 1 0 DAMPER CONNECTION IJ' NON- FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD D' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ® SMOKE DETECTOR -■- X ELECTRICAL METER 1,2 - TIMER OPERATED SWITCH 120 1 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTIUTY. ® THERMOSTAT - - - X 1 MECI-IPANICAL / ELECTRICAL COORD [NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, 11MER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL All) 2 - DISCONNECT SWITCH UNIT D BEDROOM KITCHEN LAUNDR'r 5EDRCCM 3 I \ING RCCM MAIN FLOOR PLAN 1/4" = 1' I4)-- 113 NO0 RECEIVED MAR 30 2012 PERMIT CENTER 3EPAfL4YF AP � 4 REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 - 2777.• FAX (206) 624 -2973 ENGINEERS. INS TNM lA WA S11W '..sw1 1._ nor GM NI w~ GS MN 0810.03.1841 O 0 J z O z ce W F- z z O U CD z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1841