Loading...
HomeMy WebLinkAboutPermit D12-117 - AT&T MOBILITY - EQUIPMENT CABINETSAT &T MOBILITY 16500 SOUTHCENTER PY D12 -117 City o*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 6437300010 Address: 16500 SOUTHCENTER PY TUKW Suite No: Project Name: AT &T MOBILITY Permit Number: D12-117 Issue Date: 05/15/2012 Permit Expires On: 11/11/2012 Owner: Name: CHA SOUTHCENTER LLC Address: 16500 SOUTHCENTER PKWY , SEATTLE WA 98188 Contact Person: Name: JENNIFER TAYLOR Address: 7525 SE 24 ST, SUITE 500 , MERCER ISLAND WA 98040 Contractor: Name: WREN CONSTRUCTION INC Address: 1410 80TH ST SW STE A , EVERETT, WA 98203 Contractor License No: WRENCI *013B6 Lender: Name: Address: Phone: 206 - 228 -2127 Phone: 425 - 252 -1282 Expiration Date: 01/26/2014 DESCRIPTION OF WORK: AT &T PROPOSES TO INSTALL ADDITIONAL EQUIPMENT CABINETS AT THE EXISTING WIRELESS FACILITY LOCATED AT THIS SITE. Value of Construction: $9,000.00 Fees Collected: $433.01 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0026 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -117 Printed: 05 -15 -2012 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Public: Non - Profit: N Public: Date: O I V L ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction .E the performance of work. to this permit. Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Print Name: deN\\ e( 701 or Date: 15h ) 2. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *FIRE DEPARTMENT CONDITIONS * ** 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: The battery cabinets and battery system shall comply with all applicable provisions of International Fire Code section 608. 4: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 5: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -117 Printed: 05 -15 -2012 # . O CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. b 1)-- 117 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 16500 Southcenter Pkwy King Co Assessor's Tax No.:_6437300020 Suite Number: N/A Floor: Roof Tenant Name: AT &T Mobility PROPERTY OWNER Name: Jennifer Taylor Name: CHA Southcenter LLC City: Mercer Island State: WA Zip: 98040 Address: 16500 Southcenter Pkwy Email: jtaylor @westower.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Jennifer Taylor Address: 7525 SE 24th St #500 City: Mercer Island State: WA Zip: 98040 Phone: (206) 228 -2127 Fax: Email: jtaylor @westower.com GENERAL CONTRACTOR INFORMATION Company Name: T.B.B. , 1r" Cw k WC� Address: 1/,1 fj - /' Jam", A U �Vj City: r-1�II State: lVq.. Zip: 119 �, Yom/ l�V Phone: Fax: Contr Reg No. t wiz 1 .toi3 n I $xp Date: Dd iu l ic..\ Tukwila Business License No.: m c, hi . ` f c H :\Applications\rorms- Applications On Ltne\201 I Apphcauons \Permit Application Revised - 8 -9 -1 l.docx Revised: August 2011 bh New Tenant: ❑ Yes ARCHITECT OF RECORD Company Name: Cornerstone Engineering Inc Engineer Name: Mark Olson Company Name: N/A City: Woodinville State: WA Zip: 98072 Phone: (425) 487 -1732 Fax: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Cornerstone Engineering Inc Engineer Name: Mark Olson Address: 16928 Woodinville- Redmond Rd NE Ste 21( City: Woodinville State: WA Zip: 98072 Phone: (425) 487 -1732 Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 9,000 Describe the scope of work (please provide detailed information): AT &T proposes to install additional equipment cabinets at the existing wireless facility located at this site. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes V.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Belo PLANNING DIVISION: Single family building footprint (area of the tbundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:',Applications \Forms- Applications On Line\2011 Applications\Pennit Application Revised - 8 -9 -I I.docx Revised: August 2011 bh l'age 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 n Floor 2"d Floor 3rd Floor Floors thru KO 6101\ff- in 5ck Vboto it Onoccup%kci 00 4= Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the tbundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:',Applications \Forms- Applications On Line\2011 Applications\Pennit Application Revised - 8 -9 -I I.docx Revised: August 2011 bh l'age 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O ER OR A THORIZED AGENT: Signature: Print Name: J ennifer a ylbr Mailing Address: 7525 SE 24th Street #500 11:1 Applications \Forms - Applications On Line\201 I Applications \Permit Application Revised - 8- 9- 11Acx Revised: August 2011 bh Day Telephone: Date: `5/.�9%1 Z (206) 228 -2127 Mercer Island WA City State 98040 Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 6437300010 Permit Number: D12-117 Address: 16500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 04/05/2012 Applicant: AT &T MOBILITY Issue Date: Receipt No.: R12 -01236 Initials: WER User ID: 1655 Payment Amount: $433.01 Payment Date: 04/05/2012 09:50 AM Balance: $0.00 Payee: WESTOWER COMMUNICATIONS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 115800 433.01 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $433.01 259.70 168.81 4.50 doc: Receiot -06 Printed: 04 -05 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ta., (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: _ ,r l j 4 1 (V\ o tilt -i i (-.c Type of Inspection: PIN) A L_ Address: 165a) Pc( Date Called: Special Instructions: Date Wanted:. a.m. Requester: Phone No: --p `*proved per applicable codes. Corrections required prior to approval. COMMENTS: h::;‘)/14 \ E NSPECTION FEE REQUI D. Prior to d at 6300 Southcenter Blvd., Suite 100. Date: 1 /10 ext inspection, fee must be all to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit • • : •—• ' D/2_, )17 PERMIT NUMBERS CITY OF TUKVVILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: /304bie rree.... Type of Inspection: 71—F...--t . 1 Hood & Duct: Address: /4-5-40e, 6c PAL L.4-...1 Suite #: Contact Person: Permits: OcCupancy Type: Special Instructions: Phone No.: $ , / ['proved per applicable codes. ( Corrections required prior to approval. .•,' • • ' C `� CORNERS'1rONE ENGINEERING, INC. QV /L • IRLICII/RAL . s('RVC) 16928 Woodinville- Redmond Rd NE, Suite 210 Woodinville, WA 98072 Email: cei@cornerstone-engr.com Web: www.cornerstone- engr.com Structural Calculations For Phone: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 PZ CO Battery Cabinet Installation REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION Prepared By: Checked By: Prepared Date: CEI Project No.: at &t Site Name: Tukwila Site Number: WA094 16500 Southcenter Parkway Tukwila, WA 98188 King County Tony V. Le, E.I.T. Mark W. Olson, P.E. November 16, 2011 11 -69335 ECEIVED APR 05 2012 PERMIT CENTER Comprehensive Design Solutions for Your Project Success! Project: WA094 Tukwila Date: November 16, 2011 Client: At &t Prepared By: T. L, CEI No.: 11 -69335 Page i I. Scope of Work Provide structural analysis for the proposed AT &T telecommunications (2) Argus Te40 battery cabinets on existing rooftop platform. The project is located atop the building located at 16500 Southcenter Parkway in the City of Tukwila, King County, WA. The proposed loads of the equipment transfer directly into the existing rooftop platform beams and to the load bearing columns of the building. All the loads then transfer from the load bearing columns of the building and into the foundation & to the soil. The information in this report summarizes the requirements for construction of structural elements for the proposed design in conformance with the 2009 International Building Code (IBC). Unless noted otherwise, all means and methods used shall be in keeping with good and generally accepted construction practices and all prescriptive design requirements of the 2009 IBC. II. Analysis Results As requested, we have evaluated the structural stability of the proposed additional loading for structural code compliance. This analysis derives its applied loads from minimum 85 mph basic wind speed (3- second gust), Exposure "B ". Since soil properties are not available, seismic site class "D" was conservatively used for this analysis per 2009 IBC (Section 16). III. Conclusions and Recommendations The existing rooftop platform beams are structurally adequate to support the proposed loading of the additional battery cabinets with the addition of the (2) steel L4x4x1/4 below each proposed cabinet. Please refer to the following structural calculations and supporting drawings for the equipment cabinet addition. General contractor shall verify all existing dimensions, member sizes and conditions prior to commencing any work. All dimensions of existing condition shown on the calculation are intended as guidelines only and must be verified in field. Any discrepancies shall be called to the attention of the architect or engineer and shall be resolved before proceeding with the work. Contractor shall provide temporary bracing for the structure and structural components until all final connections have been completed in accordance with the plans. IV. Loads /Design Criteria: (2009 IBC & ASCE 7 -05) Please refer to the following calculations 1. Occupancy Category - II (Standard Occupancy) 2. Seismic - Ss = 1.421g, S1 = 0.486g SOS = 0.948g, SO, = 0.491g I = 1.0, Site Class = "D ", Seismic Design Category = "D" 3. Wind - Wind Speed = 85 mph, lW = 1.0, Exposure: "B ", Topographic Factor, Kn = 1.00 16928 Woodinville- Redmond Rd NE, Suite 210 Woodinville, WA 98072 Email: cei @cornerstone - engr.com Web: www.cornerstone- engr.com CORNER51rONE ENGINEERING, INC. Phone: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 Project: WA094 Tukwila Date: November 16, 2011 Client: At &t Prepared By: T. CE1 No.: 11 -69335 Page (GJ Seismic Design Parameters (WA094 Tukwila) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.454378 Longitude = - 122.260683 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05000000074505806 deg grid spacing Period Sa (sec) (g) 0.2 1.421 (Ss, Site Class B) 1.0 0.486 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.454378 - Longitude = - 122.260683 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 =FvxS1 Site Class D - Fa = 1.0 ,Fv = 1.514 Period Sa (sec) (g) 0.2 1.421 (SMs, Site Class D) 1.0 0.736 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.454378 Longitude = - 122.260683 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2 /3xSM1 Site Class D - Fa = 1.0 ,Fv = 1.514 Period Sa (sec) (g) 0.2 0.948 (SDs, Site Class D) 1.0 0.491 (SD1, Site Class D) 16928 Woodinville- Redmond Rd NE, Suite 210 Woodinville, WA 98072 Email: cei @cornerstone - engr.com Web: www.comerstone- engr.com O CORNERSTONE ENGINEERING, INC. Phone: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 EIIICONES1rONE E N G I N E E R I N G , I N C. Site Name: WA094 Tukwila Client: At &t CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Seismic Load Calculation for Components and System (Reference: 2009 IBC, Sec. 1613 & ASCE 7 -05, Ch. 13.0, USGS Earthquake Ground Motion Parameters v5.0.9a) Seismic Force: 0.2s Spectral Response Acceleration, Site Class B, Ss = 1.421 (2009 IBC, Figure 1613.5(1)) 1.0s Spectral Response Acceleration, Site Class B, Si = 0.486 (2009 IBC, Figure 1613.5(2)) Site Class = D (2009 IBC, Table 1613.5.2) Occupancy Category = Standard - Occupancy Buildings = II Site Coefficient per Ss & Site Class, Fa = 1.00 (2009 IBC Table 1613.5.3(1)) Site Coefficient per S1 & Site Class, Fv = 1.51 (2009 IBC Table 1613.5.3(2)) SMS = FaSs = 1.421 (2009 IBC, Eq 16. -36) SM1 = F„ S1 = 0.736 (2009 IBC, Eq 16. -37) SDS = 2/3 SMS SD1 = 2/3 SM1 Seismic Design Category per SDs (Per ASCE 7 -05, Chapter 13.0) Component amplification factor, ap Component Importance factor, 1p Component operating weight, Wp Component response modification factor, Rp Height in structure at point of attachment of component, z Average roof height of structure, h Seismic Design Force, Fp 0.947 0.491 D (2009 IBC, Eq 16. -38) (2009 IBC, Eq 16. -39) 1.0 (ASCE 7 -05, Table 13.6 -1) 1.0 (ASCE 7 -05, Section 13.1.3) Wp (lb) = 2.5 (ASCE 7 -05, Table 13.6 -1) = 100 (ft) = 100 (ft) 0.4apSDSWP (1 +2z /h) Rp /Ip (Eq. 13.3 -1) Max. seismic design force, Fpmax = 1.6SDSIpWp Min. seismic design force, Fpmin = 0.3SDSIpWP Min. seismic design force, Fpmi„ = 0.28 Wp Max. seismic design force, Fpmax = 1.52 Wp (Eq. 13.3 -2) (Eq. 13.3 -3) Seismic Design Force, Fp = 0.45 Wp (No one third stress increase allowed) 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @cornerstone - engr.com Web: www.cornerstone - engr.com Tel: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 ECOUJE51rOr%JE E N G I N E E R I N G . I N C. Site Name: WA094 Tukwila Client: At &t CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Wind Load Calculation for Other Structure (Reference: 2009 IBC, Section 1609 & ASCE 7 -05, Chapter 6.0) Wind Velocity Pressure: Basic Wind Speed, Vas, (mph) Exposure Category Building Category Wind Load Importance Factor, lW Velocity pressure exposure coefficient, KZ Topographic Factor, KZt Wind Directionality Factor, Kd Velocity Pressure, qZ, (Ib /ft2) 85 (ASCE 7 -05, Figure 6 -1) = B (ASCE 7 -05, Section 6.5.6) = II (2009 IBC, Table 1604.5) = 1.00 (ASCE 7 -05, Table 6 -1) = 0.99 (ASCE 7 -05, Table 6 -3) 1.00 (ASCE 7 -05, Figure 6 -4) = 0.90 (ASCE 7 -05, Table 6 -4) Design Wind Load (Open Buildings & Other Structure) Gust effect factor, G Net force coefficient, Cf Projected area normal to the wind, Af, (ft2) Design Wind Loads, F, (lb/ft) Height Z, (ft) Exposure Case 1 B Case 2 0 -15 0.70 0.57 20 0.70 0.62 25 0.70 0.66 30 0.70 0.70 40 0.76 0.76 50 0.81 0.81 60 0.85 0.85 70 0.89 0.89 80 0.93 0.93 90 0.96 0.96 100 0.99 0.99 160 1.13 1.13 0.00256KZKZtKdV2IW (ASCE 7 -05, Eq. 6 -15) 16.48 (ASCE 7 -05, Section 6.5.10) 0.85 1.30 Af gZGCfAf lbs 18:2 psf (Af) (ASCE 7 -05, Section 6.5.8) (ASCE 7 -05, Figure 6- 20 -23) Velocity Pressure Case 1 (q2) Case 2 11.65 9.49 11.65 10.32 11.65 10.99 11.65 11.65 12.65 12.65 13.48 13.48 14.15 14.15 14.82 14.82 15.48 15.48 15.98 15.98 16.48 16.48 18.81 18.81 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @comerstone- engr.com Web: www.comerstone - engr.com Tel: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 Project: WA094 Tukwila Date: November 16, 2011 Client: At &t Prepared By: T. Le CEI No.: 11 -69335 Page Analysis of Additional Battery Cabinets 16928 Woodinville- Redmond Rd NE, Suite 210 Woodinville, WA 98072 Email: cei @cornerstone- engr.com Web: www.comerstone- engr.com CORNERSVONE E N G I N E E R I N G . I N C. Phone: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 Specifications for Argus' Te40 Outdoor Battery Enclosure Electrical Input Voltage: 120Vac, 60Hz single phase (for air conditioner) Feeder Breaker: 15A recommended Mechanical Dimensions: 2134mm H x 762mm W x 762mm D (84" H x 30" W x 30" D) Weight: 1451 kg (3200 Ib.) fully loaded with batteries Mounting: Pad or platform HVAC: Air conditioner with built -in heater Enclosure: Aluminum, 5052 -H32 Environmental Operating Temperature: Storage Temperature: -40 to +46 °C ( -40 to 115 °F) -40 to +85 °C ( -40 to +185 °F) Humidity: 0 to 95% non - condensing Elevation: Weather Tightness: Regulatory Approvals Enclosure Ratings: -50 to 4000 meters operating ( -164 to 13,123 feet) NEMA Type 3R CSA /UL Type 3R IEC enclosure designation IP56 See also Environmental (above) Telcordia: Designed to GR-487 Product Safety: CSA /UL 60950 The above information is valid of the time of publication. Consult factory for up -to -date ordering information. Specifications are subject to change without notice. Argus Technologies Ltd. 029 - 030 -B1 Rev B WC Printed in Canada. O 2009 Argus Technologies Ltd. ARGUS is a registered trademark of Argus Technologies Ltd. All Rights Reserved. 291.2 [ 11.461 CONCRETE PAD OR PLATFORM MOUNTING (USE THESE HOLES FOR SEISMIC) 015.9 [0.63] 4 PLACES CONCRETE PAD MOUNTING: DRILL AND INSTALL CONCRETE ANCHOR BOLTS, USE HILTI HSLB- M12/25 (ARGUS P/N 633 - 066 -10) OR EQUIVALENT PLATFORM MOUNTING: USE APPROPRIATE MOUNTING HARDWARE 1053.2 [41.461 DOOR OPEN 762.0 [ 30.001 693.2 [27.291 61.0 1 2.401 BASE LAYOUT (TOP VIEWI 762.0130.00] ENCLOSURE DIMENSION 706.1 [27.80] 27.9 [1.101 27.9 [1.10 640.1 [ 25.201 61.0 [2.40] 762.0 [30.001 ENCLOSURE DIMENSION 165.1 [6.50] L 431.8 [ 17.001 FRONT J 165.1 [6.50] ARGuS UNITS mmPIN x %(� .1 ;r°72 x. IX.%x� *0 .0.000 x.x%00l!xzx� :0.5S �o.nn ANGULAR. :0.5' SCALE NTS ONO TITLE OUTLINE DRAWING. PWR SYS,BATTERY ENCLOSURE,Te40 ISSUE ISNFFT 2 OF 2 DATE SIZEITYPE DWG NO. REV B D2 057- 101 -06 PiA F- 1925 ARGUS TFCNNOI.OGIE5 EICORNEISrDNE ENGINEERING. INC. Site Name: WA094 Tukwila Client: At &t CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Determine Anchorage Reactions from Wind Load (Reference: 2009 IBC, Section 1609 & ASCE 7 -05, Chapter 6) Load Combination (ASCE 7 -05, Section 2.3) 1 1.4D 2 1.2D 3 1.2D + 0.8W 4 1.2D + 1.6W 5 1.2D + 1.0E 6 0.9D + 1.6W 7 0.9D + 1.0E Argus Te40 Battery Cabinet Specifications: height of cabinet, h = width of cabinet, w = dist. between bolts, d = 84 in 30 in 25.2 in Design Parameter D = Equipment Weight (Wp) At = 17.5 IW = 1.00 Vas = 85 Exposure = B kZ = 0.99 kd = 0.90 kZf = 1.0 qZ = 0.00256 *kz *kd *kn *V3s *lw = 16.48 psf G = 0.85 Cf= 1.30 FW = qZ *G *Cf *Af = 318.7 Ibs Cabinet Specifications Argus Te40 Battery Cabinet (Empty) Equipment Weight (Wp) = h/2 = d= Argus Te40 Battery Cabinet (Full) Equipment Weight (Wp) = h/2 = d= 800 lbs 42.0 in 25.2 in 3200 lbs 42.0 in 25.2 in (ASCE 7 -05, Table 6 -1) (ASCE 7 -05, Fig. 6 -1) (ASCE 7 -05, Table 6 -3) (ASCE 7 -05, Table 6 -4) (ASCE 7 -05, Fig. 6 -4) (ASCE 7 -05, Eqn. 6 -15) (ASCE 7 -05, 6.5.8.1) (ASCE 7 -05, Fig. 6 -21) (ASCE 7 -05, Eqn. 6 -28) 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @cornerstone - engr.com Web: www.comerstone - engr.com Tel: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 ECONEFISrDNE ENGINEERING. INC. Site Name: WA094 Tukwila Client: At8it CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Anchorage Reactions Argus Te40 Battery Cabinet (Empty) V� _ 1.6F„, T„ _ T„ = 4 bolts h/2 x1.6FW - d /2x[1.2D] d x 2 bolts h /2x1.6FW - d /2x[0.9D] d x 2 bolts Argus Te40 Battery Cabinet (Full) 1.6FW Vu = T„ = T„ = 4 bolts h /2x1.6FW - d /2x[1.2D) d x 2 bolts h /2x1.6FW - d /2x[0.9D] d x 2 bolts w N V d SIDE WIND 0.13 kips 0.18 kips 0.24 kips 0.13 kips -0.54 kips -0.30 kips w FRONT 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @comerstone- engr.com Web: www.comerstone - engr.com Tel: (425) 487 -1732 (206) 250-7306 Fax: (425) 487 -1734 E,COFrJEFUSrONE • E N G I N E E R I N G , I N C. Site Name: WA094 Tukwila Client: At &t CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Determine Anchorage Reactions from Seismic Load (Reference: 2009 IBC, Section 1613 & ASCE 7 -05, Section 2,12,13) Load Combination (ASCE 7 -05, Section 2.3) 1 1.4D 2 1.2D 3 1.2D + 0.8W 4 1.2D + 1.6W 5 1.2D + 1.0E 6 0.9D + 1.6W 7 0.9D + 1.0E Argus Te40 Battery Cabinet Specifications: height of cabinet, h = 84 in width of cabinet, w = 30 in dist. between bolts, d = 25.2 in Design Parameter D = Equipment Weight (Wp) L = N/A W N/A E1 = pQE + 0.2SDSD [ASCE 7 -05, Eq.12.4-1] E2 = pQE - 0.2SosD [ASCE 7 -02, Eq.12.4 -2] p = 1.0 QE, Fp = 0.45 Wp SDS = 0.947 g Cabinet Specifications & Seismic Loads Argus Te40 Battery Cabinet (Empty) Equipment Weight (Wp) = Fp =pQE= 0.2SDSD = h/2 = d= Argus Te40 Battery Cabinet (Full) Equipment Weight w/ fuel (Wp) = Fp =pQE= 0.2SDSD = h/2 = d= 800 Ibs 363.8 Ibs 151.6 Ibs 42.0 in 25.2 in 3200 Ibs 1455.1 lbs 606.3 lbs 42.0 in 25.2 in 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @comerstone- engr.com Web: www.comerstone - engr.com Tel: (206) 250 -7306 (425) 487 -1732 Fax: (425) 487 -1734 ECDPINEFrDNE E N G I N E E R I N G. I N G. Site Name: WA094 Tukwila Client: At&tt CEI No.: 11 -69335 By: T. Le Date: 11/15/11 Subject: Lateral Load Design Calculation Anchorage Reactions Argus Te40 Battery Cabinet (Empty) V„ = 1.3 1.0p QE 4 bolts T„= 1.3 h /2x1.0p QE +d /2x[1.0(0.2SDSD) -1.2D] d x 2 bolts T„ = 1.3 h /2x1.0p QE +d /2x[1.0(0.2SDSD) -0.9D] Argus Te40 Battery Cabinet (Full) 1.0p QE V„ = 1.3 4 bolts d x 2 bolts T„ = 1.3 h/ 2x1 .0pQE +d /2x[1.0(0.2SDSD) -1.2D] d x 2 bolts T„= 1.3 h /2x1.0p QE +d/2x[1.0(0.2SDSD) -0.9D1 d x 2 bolts 2 d v SIDE SEISMIC 0.12 kips 0.13 kips 0.21 kips 0.47 kips 0.53 kips 0.84 kips 3 L w FRONT 16928 Woodinville- Redmond Rd NE, #210 Woodinville, WA 98072 E -mail: cei @comerstone- engr.com Web: www.comerstone - engr.com Tel: (206) 250 -7306 (425) 487 -1732 Fax: (425) 487 -1734 ECcMRNEFS..IrDNE E N G I N E E R I N G . I N C. project 4VA o' 1UKurl l-A location TA W I LA WA client AT d-"f by TVL date //1/5/1/ sheet no. checked date CEI job no. 11 -6f315 QUIPMEMT CA-9u ET COME'774 I PCs/thtI MAt 77 dAi s c(MM4RV Vu 1/-7-6 lb/ / 4OLT ►u= fiYo Ibs / gt —r rRy (4i) I/i "0 4363 t)c LTS. (11fv ' /8,G ksi 066= 3V/5 Psi' 4 410 /Al- _ Dl10-0/a, t16 IA z 0, og < 1,6 0K- /0,6 �� "✓ T lA GSfoK /o,19&r�i - D,13 < l o 0 61 ...4 less Qk usE (y) 'la "rd A303 ad LT 74 ANCM K blotP/'iEMT CAR 7 10 ' /I/ SUPPoV r ACM. ECoFNEiRs1roNE E N ENGINEERING, N E E R I N G. I N C. project by location date sheet no. client checked date CEI job no. EmAINENT 51AFFogi REAM 1)1514N TIN OX4'X V4. wTtw, % (32o6 Ibs /1,5')/2 = 6* 141E43 l "125' 2,5' R 3,0' ONNW(AN OCCIO ,1 r'1 (1) 5/43110 A364 B6(-1, 061v= )5,0k; v� t I M` — = 6.2a1 < 1.0 0, 2 s' 01111 OK A CORCP (1,4b Va /A _ II'I R /A _ I,4 (bM d 9 /o,3o6 ; ri z D,Z1 L l,0 064 Ofkv 19, a k<r 1)/0XW1y S4PPoZT i3tilVvi w/ sly'" Aid? B61.--Ts ATTA6f1MAAJT TO CO (SIDE H .. M6iE BE!t'1 S TQ Scots E`gdIPMENT a1BIA)FT, ECDRNERST.DNE Steel Beam Lic. # : KW- 06006053 Description : L4x4x1 /4 Support Beam Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Completely Unbraced Bending Axis : Major Axis Bending Load Combination 2006 IBC & ASCE 7 -05 Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 Printed: 15 NOV 2011, 3:01 PM e: Z:1DatalStoragelCornerstone \Engineering AT &71_2011111 -69335 WA094 Tukwila ETC1Calcslwa094 tukwila.ec6 ENERCALC, INC. 1983 -2011, Build:6.11.9,30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Calculations per AISC 360 -05, IBC 2009, CBC 2010, ASCE 7-05 Fy : Steel Yield : 36.0 ksi E: Modulus : 29,000.0 ksi Applied Loads Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.640 k/ft, Extent = 0.250 - DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward L +Lr +S Deflection Max Upward L +Lr +S Deflection Max Downward Total Deflection Max Upward Total Deflection L4X4X1 /4 Service loads entered. Load Factors will be applied for calculations. -» 2.750 ft, Tributary Width = 1.0 ft 10.297 : 11 -Maximum Shear Stress Ratio = L4X4X1/4 Section used for this span 0.990 k -ft Vu : Applied 3.337 k -ft Vn * Phi : Allowable +1.40D 1 500f Span # 1 0.000 in 0.000 in 0.013 in 0.000 in Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V max Mu + +1.40D Dsgn. L = 3.00 ft 1 0.297 0.058 0.99 Overall Maximum Deflections - Unfactored Loads Ratio = Ratio = Ratio = Ratio = Load Combination Location of maximum on span Span # where maximum occurs 0 <360 0 <360 2726 0 <180 Design OK 0.058 : 11 L4X4X1 /4 1.134 k 19.440 k +1.40D 3.000 ft Span # 1 Summary of Moment Values Summary of Shear Values max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx Load Combination Span Max. " " Deft Locat 0.99 3.71 3.34 1.14 1.00 1.13 21.60 19.44 ion in Span Load Combination Max. " +" Defl Location in Span 1 0.0000 0.000 Maximum Deflections for Load Combinations - Unfactored Loads Load Combination Span Max. Downward Defl Location in Span 0.0000 0.000 Max. Upward Defl Location in Span D Only 1 0.0132 Vertical Reactions - Unfactored Load Combination Support 1 Support 2 1.515 Support notation : Far left is #1 0.0000 0.000 Values in KIPS Overall MAXimum 0.810 0.810 D Only 0.810 0.810 OC.CORNERSTONE E N G I N E E R I N G , I N C. Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Seel Beam Job# 11 -69335 Printed: 15 NOV 2011, 3 01P le: Zl DatalStoragel Cornerstone I Engineering \AT &Tt_2011 \11 -69335 WA094 Tukwila ETC ICalcslwa094 tukwila.ec6 ENERCALC, INC. 1983-2011, Build:6.11.9.30, Ver:6.11.9.30 Lic. # : KW- 06006053 Licensee : CORNERTSTONE ENGINEERING INC. Description : L4x4x1/4 Support Beam Steel Section Properties : L4X4X114 Depth Leg Width Thickness Area Weight Kdesign Ycg Yp Eo 1.0 0.8 0.5 0.3 BEAM - - -s> 12 0.6 L. BEAM - - -» -0.6 -1.2 BEAM - - -a> -0,003 -0.007 -0.010 -0.013 4.000 in 1 xx Sxx 4,000 in R xx 0.250 in Zx 1.940 in ^2 I yy 6.600 plf S yy 0.625 in R yy 1.080 in Qs Iz 0.242 in 0.242 in Sz Rz Tarp 3.00 in^4 1.03 in03 1.250 in 1.820 in03 3.000 in^4 1.030 in03 1.250 in 0.910 1.180 in^4 0.419 in03 0.783 in 1.00 deg J Cw Ro 0.044 in"4 0.05 inA6 2.220 in 0.29 0,59 0.89 1.19 1.49 Distance (ft) ■ «1.410 1.79 2.09 2.39 2.69 2.99 0.29 0.59 0.89 1.19 1.49 Distance (ft) • +1.40D 1.79 2.09 2.39 2.69 2.99 0.29 0.59 0.89 1.19 1,49 Distance (ft) • D O..ly 1.79 2.09 2.39 2.69 2.99 EcoFNeF91roNE E N G I N E E R I N G, I N C. project location by date sheet no. client checked date CEI job no. PRGP&IEP LAB//JET r4u1P1HENT. CA-8/A1tT SLwPp6ZT BEAM CoNNEGTION. DETAIL (E) PARAPET WALL (E) W10x33 [87] (E) UMT (F) TE -L cm m (P) L4X4X1/4, BELOW CABINET cv o 11 (TYP OF 2 PER CABINET) (E) W10X26 [B8] 8' -1" 4' -0" 4' -0" 2' -4" 27-9" 4' -0" (E) LOAD BEARING COLUMNS, BELOW (E) PLATFORM PIPE (TYP) COLUMNS (TYP OF 4) PLATFORM LAYOUT PLAN NORTH ECOFRNERS1rDNE ENGINEERING, INC. project ui A01,/ 7711<14)1 LA by location rLikt/1LA4, W4 client A/ I1T date 1;1/1/0 checked date CEI job no. 18-69/72 tLATFoRM LOADS 1)I: AD Loos F6R8 PMENT (0 NOK ►A (tVtV = 3) = e 161 x 3 (n t 1 Ts (01-v = 1) _ jqa lb f 1)T-Lo (411 -":1) = 2bda (b! (0XAiifr{ (qTY =0 _ 2sa X61 (0 TE `f3 (011=1) = 37.60 Ids (1) TE:10 (f7v = 2) = 3zo0 Ids 6 RAT tl1/4161 t- mist. la p$ (� f� _ �s /s` LIVE /AA() fs-f (RES7R(c1 P AREA) CORNERSIrONE _ N G I N E E R I N G, I N C. project location by date sheet no client checked date CEI job no (e) wf3xl3 [ IF DO 0tfEGK wags- CASE SEAM > (E) W BX 13 De] IKIB MDT// = z (Z'- Y'14-3' -a ") = 247' IPA_ +LL = ( f f p .( f 2s PJ-r) (2. ? = 9D pJ-f + 6b,? plY w7l:iO _ (Zhoo IV( /7,0 /2 = 57a pJ-f W TEyo = (.?2oo Ihs /2,5')2 = Cfd fig tAi W1fzo iiL'tu I .[ i'‘)PL +LL X .I' -� 1,5 2.s' Z5' 1 fi5' /CI Mu O.68I < I, o �DMh OK L tqD & ( I7 w6 g51- CAst .: (o wx i Cho- f Bbl I3I✓AA4$ ASE / P I ATE To 5c/pe'R r rROQDSMM EQUIP 4 J1 CABINET. v ECORNEFIS.1FONE - ENGINEERING, INC. Steel Beam Lic. # : KW- 06006053 Description : (E) W8x13 [B1] - [B6] Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam bracing is defined Beam -by -Beam Bending Axis : Major Axis Bending Load Combination 2006 IBC & ASCE 7 -05 Unbraced Lengths Span # 1, Braced @ 1/3 Points Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 20 Printed: 15 NOV 2011, 3:49PM e: Z:\Data\Storage\Comerstone\EngineeringAT&T\_201 1\1 1-69335 WA094 Tukwila ETC \Calcs \wa094 tukwila.ec6 ENERCALC, INC. 1983.2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Calculations per AISC 360 -05, IBC 2009, CBC 2010, ASCE 7-05 Fy : Steel Yield : 36.0 ksi E: Modulus : 29,000.0 ksi D(0.040) L(0.06670) v D(0.64) * D(0.52) 1' D(0.64) i i i i 4 * * $ $ i i Applied Loads Span = 15.0 ft W8X13 Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Loads on all spans... Uniform Load on ALL spans : D = 0.040, L = 0.06670 k/ft Load for Span Number 1 Uniform Load : D = 0.520 k /ft, Extent = 6.250 - -» 8.750 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.640 k /ft, Extent = 8.750 - -» 11.250 ft, Tributary Width = 1.0 ft Uniform Load : D = 0.640 k/ft, Extent = 3.750 - -» 6.250 ft, Tributary Width = 1.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = j 0.681 : 11 Maximum Shear Stress Ratio = Section used for this span W8X13 Section used for this span Mu : Applied 19.755 k -ft Vu : Applied Mn * Phi : Allowable 29.003 k -ft Vn * Phi : Allowable Load Combination +1.20D +0.50Lr +1.60L +1.60H Load Combination Location of maximum on span 7.500ft Location of maximum on span Span # where maximum occurs Span # 1 Span # where maximum occurs Maximum Deflection Max Downward L +Lr +S Deflection 0.067 in Ratio = 2699 Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.544 in Ratio = 330 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Design OK 1 0.100 : 1 W8X13 3.978 k 39.694 k +1 .20 D +0.50 L r +1.60 L +1.60 H 0.000 ft Span # 1 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx +1.40D Dsgn. L = 4.95 ft 1 0.546 0.093 16.80 16.80 34.20 30.78 1.61 1.00 3.71 39.69 39.69 Dsgn. L = 5.03 ft 1 0.674 0.057 19.55 16.80 19.55 32.23 29.00 1.02 1.00 2.26 39.69 39.69 Dsgn. L = 5.03 ft 1 0.551 0.093 16.96 16.96 34.20 30.78 1.58 1.00 3.71 39.69 39.69 +1.20D+0.50Lr +1.60L +1.60H Dsgn. L = 4.95 ft 1 0.554 0.100 17.05 17.05 34.20 30.78 1.59 1.00 3.98 39.69 39.69 Dsgn. L = 5.03 ft 1 0.681 0.056 19.76 17.05 19.76 32.23 29.00 1.02 1.00 2.21 39.69 39.69 Dsgn. L = 5.03 ft 1 0.559 0.100 17.21 17.21 34.20 30.78 1.56 1.00 3.98 39.69 39.69 +1.20D +1.60L+0.50S +1.60H Dsgn. L = 4.95 ft 1 0.554 0.100 17.05 17.05 34.20 30.78 1.59 1.00 3.98 39.69 39.69 Dsgn. L = 5.03 ft 1 0.681 0.056 19.76 17.05 19.76 32.23 29.00 1.02 1.00 2.21 39.69 39.69 Dsgn. L = 5.03 ft 1 0.559 0.100 17.21 17.21 34.20 30.78 1.56 1.00 3.98 39.69 39.69 +1.20D +1.60Lr+0.50L Dsgn. L = 4.95 ft 1 0.495 0.086 15.23 15.23 34.20 30.78 1.60 1.00 3.43 39.69 39.69 Dsgn. L = 5.03 ft 1 0.610 0.051 17.69 15.23 17.69 32.23 29.00 1.02 1.00 2.03 39.69 39.69 Dsgn. L = 5.03 ft 1 0.500 0.086 15.38 15.38 34.20 30.78 1.57 1.00 3.43 39.69 39.69 +1.20D+0.50L +1.60S Dsgn. L = 4.95 ft 1 0.495 0.086 15.23 15.23 34.20 30.78 1.60 1.00 3.43 39.69 39.69 Dsgn. L = 5.03 ft 1 0.610 0.051 17.69 15.23 17.69 32.23 29.00 1.02 1.00 2.03 39.69 39.69 Dsgn. L = 5.03 ft 1 0.500 0.086 15.38 15.38 34.20 30.78 1.57 1.00 3.43 39.69 39.69 +1.20D+0.50Lr+0.50L +1.60W EIIICDRNEE.rONE E N G I N E E R I N G , I N C. Steel Beam Lic. # : KW- 06006053 Description : (E) W8x13 [B1] - [B6] Load Combination Segment Length Span # Max Stress Ratios M V max Mu + Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 Printed: 15 NOV 2011, 3A9PM e: Z:1 Data \ Storage \Cornerstone \EngineeringlAT &71_2011 \11 -69335 WA094 Tukwila ETC ICalcslwa094 tukwila.ec6 ENERCALC, INC. 1983 -2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Summary of Moment Values Summary of Shear Values max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx Dsgn. L = 4.95 ft Dsgn. L = 5.03 ft Dsgn. L = 5.03 ft +1.20D+0.50L+0.50S +1.60W Dsgn. L = 4.95 ft Dsgn. L = 5.03 ft Dsgn. L = 5.03 ft +1.20 D+O.50 L+0.20 S+E Dsgn. L = 4.95 ft Dsgn. L = 5.03 ft Dsgn. L = 5.03 ft Overall Maximum Deflections - Load Combination 0.495 0.086 0.610 0.051 0.500 0.086 0.495 0.086 0.610 0.051 0.500 0.086 0.495 0.086 0.610 0.051 0.500 0.086 Unfactored Loads 15.23 17.69 15.38 15.23 17.69 15.38 15.23 17.69 15.38 15.23 15.23 17.69 15.38 15.23 15.23 17.69 15.38 15.23 15.23 17.69 15.38 34.20 32.23 34.20 34.20 32.23 34.20 34.20 32.23 34.20 30.78 29.00 30.78 30.78 29.00 30.78 30.78 29.00 30.78 1.60 1.00 1.02 1.00 1.57 1.00 1.60 1.00 1.02 1.00 1.57 1.00 1.60 1.00 1.02 1.00 1.57 1.00 3.43 39.69 39.69 2.03 39.69 39.69 3.43 39.69 39.69 3.43 39.69 39.69 2.03 39.69 39.69 3.43 39.69 39.69 3.43 39.69 39.69 2.03 39.69 39.69 3.43 39.69 39.69 Span Max. "" Defl Location in Span Load Combination Maximum Deflections for Load Load Combination 1 0.0000 Combinations • Unfactored Span Max. Downward Defl 0.000 Loads Location in Span Max. " +" Defl Location in Span 0.0000 0.000 D Only 1 0.4773 L Only 1 0.0667 D+L 1 0.5440 Vertical Reactions - Unfactored Load Combination Support 1 Support 2 Overall MAXimum 3.148 3.148 D Only 2.648 2.648 L Only 0.500 0.500 D+L 3.148 3.148 Steel Section Properties : W8X13 Depth = 7.990 in 1 xx Web Thick = 0.230 in S xx Flange Width = 4.000 in R xx Flange Thick = 0.255 in Zx Area = 3.840 inA2 I yy Weight = 13.071 plf S yy Kdesign = 0.555 in R yy K1 = 0.563 in Zy rts = 1.030 in rT Ycg = 3.995 in 20 15 10 5 BEAM• - -ra 7.575 7.575 7.575 Support notation : Far left is #1 Max. Upward Defl 0.0000 0.0000 0.0000 Location in Span 0.000 0.000 0.000 Values in KIPS 39.60 in04 9.91 inA3 3.210 in 11.400 inA3 2.730 in A4 1.370 in ^3 0.843 in 2.150 inA3 1.010 in Cw Wno Sw Qf Qw 0.087 in^4 40.80 in06 7.740 inA2 1.970 in ^4 1.860 inA3 5.550 inA3 1A3 2.93 4.43 5.93 7,43 8.93 10.43 11.93 13.43 14.93 Distance (ft) • +1.411D • +1.20D+D.SDL. +1.6DL +1.6011 • +1.20D +1.60L +0.511 +1.6D11 • +1.200 +1.60L' +D.5DL • +1.200 +D.5DL +1.605 ■ +1.200 +0.5D0+0.50L +1.60W • +1.20D +D.5DL +0.505 +1.60W • +1.200 +D.1DL +0.205. ECDRNESYONE ENGINEERING, I N C. Steel Beam Lic. # : KW- 06006053 Description : (E) W8x13 [B1] - [B6] 4.1 2.0 Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 2Z Printed: 15 NOV 2011, 3 49P e: Z:1DatalStorage\ Cornerstone \Engineering\AT &T\_2011111 -69335 WA094 Tukwila ETCICalcslwa094 tukwila.ec6 ' ENERCALC, INC. 1983 -2011, Build:6.11.9.30, Ver6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. -2A •4.1 1.43 2.93 4,43 5.93 7.43 Distance (ft) ■ +1.40D • +1.200 +0.501. +1.6DL +1.60M • +1.2DD +1.6DL +0.505 +1.00M • +1.200 +1.60L +0.501. t +1.20D +0.501.+1.6DS • +1.200 +0.501., +15.501..+1.6DW ! +1.20D +15.SOL +0.5DS+1.6DW • +1.200 +D.SDL +02DS. BEAM---” 8,93 10.43 11.93 13.43 14,93 .0.14 E -0.28 -0.42 -0.55 1.43 2.93 4.43 5.93 7.43 Distance (ft) ■ DO•ly • LO.Iy • D +L 8.93 10.43 11.93 13.43 14.93 ECoFNERs1rDNE E N G I N E E R I N G, I N C. project by location date sheet no. client checked date CEI job no. (E)wlox33 CNE6K fill$ wI�TK= 4 (/5'0") = 7,s' (1.11, L+ LL ' (0-f51 + 2C 1ST) (1'59 I/2,5- p)1' 4- t /8',S pif P = [72)046q)/2](74 �e) - C(3x8(l5)h](. -) ° 868 16s PZ 01)UMrs - (1)Tuq. ] /2] (70%) = 17714+37,00) I2] [(I)TUIO 12 + (1)1EZ° Ad= 3200 12 + 2600 /4 = 2z Ps PL WvLtt ► ` ft P1 P3 N g, k k �I 1,33' b,33/ RL . 2713-5' Ik14 = 0, 3- 3 o < I, o OfC ( 31/.30 /k. LL= l30lby N - + >DL= bs2.-1 /ss LL= 230s Ik (00.110x33 PERM 15' AOtigA1t 7O siPPORT FkoPast-d kUIPI4Etij (4tINtT ECORNR ES..rONE GINEERING, INC. Steel Beam Lic. # : KW- 06006053 Description : (E) W10x331B71 Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam bracing is defined Beam -by -Beam Bending Axis : Major Axis Bending Load Combination 2006 IBC & ASCE 7 -05 Unbraced Lengths Span # 1, Braced @ 1/3 Points Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 Printed: 15 NOV 2011, 3.50PM e: Z:IDatalStorage\ Cornerstone \Engineering\AT &T\_2011\11 -69335 WA094 Tukwila ETC \Calcs \wa094 tukwila.ec6 ENERCALC, INC. 1983-2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Calculations per AISC 360 -05, IBC 2009, CBC 2010, ASCE 7.05 Fy : Steel Yield : 36.0 ksi E: Modulus : 29,000.0 ksi Applied Loads Span = 27.750 ft W10X33 Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Loads on all spans... Partial Length Uniform Load : D = 0.1125, L = 0.1875 k /ft, Extent = 8.0 - -» 27.750 ft Load(s) for Span Number 1 Point Load: D = 0.8880 k 12.0 ft Point Load: D = 2.285 k 16.0 ft Point Load : D = 1.397 k 18.333 ft Point Load : D = 2.250 k 24.750 ft DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward L +Lr +S Deflection Max Upward L +Lr +S Deflection Max Downward Total Deflection Max Upward Total Deflection +1.20D+0.50Lr +1 t 0.730:11 ✓ Maximum Shear Stress Ratio = W10X33 Section used for this span 76.441 k -ft Vu : Applied 104.760 k -ft 60L+1 60H 15 956f Span # 1 0.413 in Ratio = 0.000 in Ratio = 1.533 in Ratio = 0.000 in Ratio = Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Vn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs 806 0 <360 217 0 <180 Design OK [ 0.191 : 1 W10X33 11.642 k 60.949 k +1 .2 0 D+0.50 L r +1.60 L +1.60 H 27.750 ft Span # 1 Summary of Moment Values Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm Summary of Shear Values VuMax Vnx Phi *Vnx +1.40D Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50Lr +1.60L +1.60H Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D +1.60L+0.50S +1.60H Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D +1.60Lr+0.50L Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50L +1.60S Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft 1 0.401 0.079 1 0.582 0.069 1 0.537 0.150 1 0.526 0.102 1 0.730 0.088 1 0.675 0.191 1 0,526 0.102 1 0.730 0.088 1 0.675 0.191 1 0.401 0.079 1 0.571 0.068 1 0.527 0.148 1 0.401 0.079 1 0.571 0.068 1 0.527 0.148 42.03 42.03 116.40 104.76 1.65 1.00 4.81 60.95 60.95 61.01 42.03 61.01 116.40 104.76 1.07 1.00 4.21 60.95 60.95 56.23 56.23 116.40 104.76 1.45 1.00 9.13 60.95 60.95 55.14 55.14 116.40 104.76 1.66 1.00 6.23 60.95 60.95 76.44 55.14 76.44 116.40 104.76 1.05 1.00 5.37 60.95 60.95 70.71 70.71 116.40 104.76 1.44 1.00 11.64 60.95 60.95 55.14 55.14 116.40 104.76 1.66 1.00 6.23 60.95 60.95 76.44 55.14 76.44 116.40 104.76 1.05 1.00 5.37 60.95 60.95 70.71 70.71 116.40 104.76 1,44 1.00 11.64 60.95 60.95 42.00 42.00 116.40 104.76 1.65 1.00 4.78 60.95 60.95 59.84 42.00 59.84 116.40 104.76 1.06 1.00 4.16 60.95 60.95 55.23 55.23 116.40 104.76 1.45 1.00 9.02 60.95 60.95 42.00 42.00 116.40 104.76 1.65 1.00 4.78 60.95 60.95 59.84 42.00 59.84 116.40 104.76 1.06 1.00 4.16 60.95 60.95 55.23 55.23 116.40 104.76 1.45 1.00 9.02 60.95 60.95 `�• CORNERSTONE E N G I N E E R I N G , I N C. Steel Beam Lic. # : KW- 06006053 Description : (E) W10x33 [B71 Load Combination Segment Length Max Stress Ratios Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 25 Printed: 15 NOV 2011, 3 50P e: Z:IData\ Storage \Cornerstone \EngineeringlAT &T1 2011111 -69335 WA094 Tukwila ETC ICalcslwa094 tukwila.ec6 ENERCALC, INC. 1983 -2011, Build:6.11.9.30, Ver6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Summary of Moment Values Span # M V max Mu + max Mu - Mu Max Summary of Shear Values Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx +1.20D+0.50Lr+0.50L +1.60W Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50L+0.50S +1.60W Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50L+0.20S+E Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft 0.401 0.079 42.00 42.00 116.40 104.76 1.65 1.00 4.78 60.95 60.95 0.571 0.068 59.84 42.00 59.84 116.40 104.76 1.06 1.00 4.16 60.95 60.95 0.527 0.148 55.23 55.23 116.40 104.76 1.45 1.00 9.02 60.95 60.95 0.401 0.079 42.00 42.00 116.40 104.76 1.65 1.00 4.78 60.95 60.95 0.571 0.068 59.84 42.00 59.84 116.40 104.76 1.06 1.00 4.16 60.95 60.95 0.527 0.148 55.23 55.23 116.40 104.76 1.45 1.00 9.02 60.95 60.95 1 0.401 0.079 1 0.571 0.068 1 0.527 0.148 42.00 42.00 116.40 104.76 1.65 1.00 4.78 60.95 60.95 59.84 42.00 59.84 116.40 104.76 1.06 1.00 4.16 60.95 60.95 55.23 55.23 116.40 104.76 1.45 1.00 9.02 60.95 60.95 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. "" Defl Locatio n in Span Load Combination 1 0.0000 Maximum Deflections for L oad Combinations - Unfactored Load Combination Span Max. Downward Defl D Only 1 1.1203 L Only 1 0.4129 D +L 1 1.5331 Vertical Reactions - Unfactored Load Combination Support 1 Support 2 Overall MAXimum 4.756 8.906 D Only 3.438 6,521 L Only 1.318 2.385 D+L 4.756 8.906 Steel Section Properties : W10X33 Depth = 9.730 in Web Thick = 0.290 in Flange Width Flange Thick Area Weight Kdesign K1 its Ycg 78 58 39 19 BEAM-r). = 7.960 in • 0.435 in • 9.710 in02 • 33.053 plf • 0.935 in = 0.750 in • 2.200 in 4.865 in 0.000 Loads Location in Span Max. " +" Defl 0.0000 Location in Span 0.000 Max. Upward Defl Location in Span 14.569 14.291 14.430 Support notation : Far left is #1 0.0000 0.0000 0.0000 0.000 0.000 0.000 Values in KIPS I xx S xx R xx Zx in( S yy R yy Zy rT 171.00 in04 35.00 in ^3 4.190 in 38.800 in ^3 36.600 in^4 9.200 in ^3 1.940 in 14.000 in ^3 2.140 in Cw Wno Sw Qf Qw 0.583 in44 791.00 in ^6 18.500 in02 16.000 in04 7.750 in ^3 18.900 inA3 2.64 0.41 8.19 10.96 13.74 16.51 19.29 22.06 24.84 27.61 Distance (ft) • +1.400 • +1.200 +D.SDL. +1.601 +1.608 • +1.20D +1.681 +8.501 +1.608 • +1.200 +1.6DL. *D.501 • +1.20D +0•6DL +1.685 • +1.2DD +D.SDL. +D.SDL +1.6DW • +1.210 +0.501 +0.501 +1.60W • +1.260 +0.501 +0.201• _,_di CORNERSTONE ENGINEERING, INC. Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 Printed: 15 NOV 2011, 3 :50PM Steel Beam Lic. # : KW- 06006053 Description : (E) W10x33 [B7] 6 2 BEAM - - -s» -3 -7 -12 e: Z9 Data1StoragelCornerstone \Engineering1AT &T1_2011\11 -69335 WA094 Tukwila ETC\Calcslwa094 tukwila.ec6 ENERCALC, INC, 1983-2011, Build:6.11.9.30, Ver.6,11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. • 2.64 5.41 8.19 10.96 13.74 16.51 19.29 22.06 24.84 27.61 Distance (Ft) • +1.400 • +1.ZDD +D.SDL. +0.6DL +1.606 ■ +1.200 +1.60L +0.505 +1.606 E +1.26D +1.615L. +0.5DL ■ +1.200 +O.SOL +1.655 ■ +1.200 +O.S01. +0.501 +1.60W ■ +1.ZDD +D.50t +D.S05 +1.6DW ■ +1.200 +D.5DL +0.20• BEAM---> 2.64 5.41 8.19 10.96 13.74 Distance (Ft) It DO•ly ■ LO.,Iy • D +L 16,51 19.29 22.06 24.84 27.61 ETCONEPR1rONE • E N G I N E E R I N G , I N C. project by location date sheet no. client checked date CEI job no. (0)w1oxti Bel C tGK T[llg vi 1 D TIi = i (Is! a') = 4-6 II 2, S pig f 163.5 1', _ (`'I /Oil (309e) _ (088 /0,3-)(0,3) = 381 lb/ �s = (Pi /0O) (3696) = (1311"(0,1) (0,3); 59q (�s 2256 Ibs 1�4 WIE 1 1 -12' ■ .i' �' XI V' 233 6,2)' 1' 2' (MIA = 6.720 < / o OK ((EMI , 2ra11 /2'= 1)..c pi( Rt.g DL = 2237-165 LL = i. /8 Its RRB => DL = 5-/b lds LL= 2385 /bs ••• (0 WIOXzb CB6:] gE AM Is ADCOLAPE To SaPQoRT PRoreflp E41IpMENT CAR INET ` ►ii CORNEF S'11rONE ENGINEERING, INC. Steel Beam Lic. # : KW- 06006053 Description : (E) W10x33 [B8] Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam bracing is defined Beam -by -Beam Bending Axis : Major Axis Bending Load Combination 2006 IBC & ASCE 7 -05 Unbraced Lengths Span # 1, Braced @ 1/3 Points Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 y�l Printed: 15 NOV2011, 3 51P e: Z: 1Datal StoragelCornerstone \Engineering\AT &71_2011\11 -69335 WA094 Tukwila ETC \Calcslwa094 tukwila.ec6 ENERCALC. INC.1983- 2011, Build:6.11.930, Ver..6,11,9.30 Licensee : CORNERTSTONE ENGINEERING INC. Calculations per AISC 360 -05, IBC 2009, CBC 2010, ASCE 7 -05 Fy : Steel Yield : E: Modulus : 36.0 ksi 29,000.0 ksi D(0.381)V D(0.1125 L(0.1875) D(0.98) Dt0.599) i D(2.25) D(0.125)* * Applied Loads Beam self weight calculated and added to loads Loads on all spans... Partial Length Uniform Load : D = 0.1125, L = 0. Load(s) for Span Number 1 Point Load: D= 0.3810 k( a)12.0ft Point Load : D = 0.980 k 0 16,0 ft Point Load: D = 0.5990 k( a)18.333ft Point Load : D = 2.250 k 0 24.750 ft Uniform Load : D = 0.1250 k/ft, Extent = 25.750 - DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn * Phi : Allowable Span = 27.750 ft W 10X26 Service loads entered. Load Factors will be applied for calculations. 1875 k /ft, Extent = 8.0 - -» 27.750 ft -» 27.750 ft, Tributary Width = 1.0 ft l 0.7 20 : 11 /Maximum Shear Stress Ratio = W10X26 Section used for this span 56.938 k -ft Vu : Applied 79.079 k -ft Vn * Phi : Allowable Load Combination +1.20D +0.50Lr +1.60L +1.60H Location of maximum on span 15.956ft Span # where maximum occurs Span # 1 Maximum Deflection Max Downward L +Lr +S Deflection Max Upward L +Lr +S Deflection Max Downward Total Deflection Max Upward Total Deflection 0.490 in Ratio = 0.000 in Ratio = 1.348 in Ratio = 0.000 in Ratio = Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V Load Combination Location of maximum on span Span # where maximum occurs 679 0 <360 246 0 <180 Design OK 0.173 : 1 1 W10X26 10.013 k 57.845 k +1 .20 D +0.50 L r +1.60 L +1.60 H 27.750 ft Span # 1 Summary of Moment Values Summary of Shear Values max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx +1.40D Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50Lr +1.60L +1.60H Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+1 60 L+0.50 S +1.60 H Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D +1.60Lr+0.50L Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20Di'0.50L +1.60S Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft 0.320 0.054 27.05 0.476 0.045 38.26 0.427 0.125 36.10 0.500 0.083 42.29 0.720 0.069 56.94 0.633 0.173 53.46 0.500 0.083 42.29 0.720 0.069 56.94 0.633 0.173 53.46 0.345 0.058 29.16 0.506 0.048 40.34 0.449 0.128 37.98 1 0.345 0.058 29.16 1 0.506 0.048 40.34 27.05 93.90 84.51 1.65 1.00 3.13 57.84 57.84 27.05 38.26 89.22 80.29 1.06 1.00 2.62 57.84 57.84 36.10 93.90 84.51 1.35 1.00 7.23 57.84 57.84 42.29 93.90 84.51 1.66 1.00 4.79 57.84 57.84 42.29 56.94 87.87 79.08 1.04 1.00 4.00 57.84 57.84 53.46 93.90 84.51 1.38 1.00 10.01 57.84 57.84 42.29 93.90 84.51 1.66 1.00 4.79 57.84 57.84 42.29 56.94 87.87 79.08 1.04 1.00 4.00 57.84 57.84 53.46 93.90 84.51 1.38 1.00 10.01 57.84 57.84 29.16 93.90 84.51 1.65 1.00 3.34 57.84 57.84 29.16 40.34 88.62 79.76 1.05 1.00 2.79 57.84 57.84 37.98 93.90 84.51 1.37 1.00 7.39 57.84 57.84 29.16 93.90 84.51 1.65 1.00 3.34 57.84 57.84 29.16 40.34 88.62 79.76 1.05 1.00 2.79 57.84 57.84 __II CORNERS -TONE E N G I N E E R I N G , I N C. Steel Beam Lic. # : KW- 06006053 Description : (E) W10x33 [B8] Load Combination Segment Length Max Stress Ratios Span # M V Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 -- Printed: 15 NOV 2011, 3.51PM e: Z:\Data\Storage\Cornerstone\EngineerjngsAj&fl_2o1 1\1 1-69335 WA094 Tukwila ETC\Calcslwa094 tukwila.ec6 ENERCALC, INC. 1983-2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Summary of Moment Values Summary of Shear Values max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi "Vnx Dsgn. L = 9.30 ft +1.20D+0.50Lr+0.50L +1.60W Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D40.50L+0.50S +1.60W Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft +1.20D+0.50L+0.20S+E Dsgn. L = 9.16 ft Dsgn. L = 9.30 ft Dsgn. L = 9.30 ft 0.449 0.128 37.98 37.98 93.90 84.51 1.37 1.00 7.39 57.84 57.84 0.345 0.058 29.16 29.16 93.90 84.51 1.65 1.00 0.506 0.048 40.34 29.16 40.34 88.62 79.76 1.05 1.00 0.449 0.128 37.98 37.98 93.90 84.51 1.37 1.00 0.345 0.058 29.16 29.16 93.90 84.51 1.65 1.00 0.506 0.048 40.34 29.16 40.34 88.62 79.76 1.05 1.00 0.449 0.128 37.98 37.98 93.90 84.51 1.37 1.00 1 0.345 1 0.506 1 0.449 0.058 29.16 29.16 93.90 84.51 1.65 1.00 0.048 40.34 29.16 40.34 88.62 79.76 1.05 1.00 0.128 37.98 37.98 93.90 84.51 1.37 1.00 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. "" Defl Location in Span Load Combination 3.34 2.79 7.39 3.34 2.79 7.39 3.34 2.79 7.39 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 57.84 1 0.0000 0.000 Maximum Deflections for Load Combinations • Unfactored Loads Max. " +" Defl Location in Span 0.0000 0.000 Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span D Only 1 0.8583 14.569 L Only 1 0.4903 14.291 D+L 1 1.3484 14.569 Vertical Reactions • Unfactored Load Combination Support 1 Support 2 Overall MAXimum 3.555 7.549 D Only 2.237 5.164 L Only 1.318 2.385 D+L 3.555 7.549 Steel Section Properties : W10X26 Depth = 10.300 in 1 xx Web Thick = 0.260 in S xx Flange Width = 5.770 in R xx Flange Thick = 0.440 in Zx Area = 7.610 inA2 I yy Weight = 25.904 pif S yy Kdesign = 0.740 in R yy K1 = 0.688 in Zy rts = 1.580 in rT Ycg = 5.150 in 1 58 44 29 15 BEAM - - -» Support notation : Far left is #1 0.0000 0.0000 0.0000 0.000 0.000 0.000 Values in KIPS 144.00 iO4 27.90 inA3 4.350 in 31.300 inA3 14.100 inA4 4.890 inA3 1.360 in 7,500 inA3 1.540 in Cw Wno Sw Qf Qw 0.402 inA4 345.00 i06 14.200 inA2 9.030 inA4 5.980 inA3 15.400 inA3 2.64 5.41 8.19 10.96 13.74 16.51 19.29 22.06 24.84 27.61 Distance (Ft) • +1.45D • +1.2 0D+0.517,10+1.6 0L +1.600 ■ +1.200+1.6131.+0.5 05+1.6011 • +1.2DD +1.6 DLL +D.SDL ■ +1.2D0+D.5 0L +1.6 05 • +1.211D +0.5DL. +0.5 0L +1.6 OW • +1.2 0D+0.5 DL +D.506 +1.6 OW • +1.21/D +D.SDL +0.265• � CORNERS'Q'ONE ENGINEER 1 NG, INC. i Steel Beam Lic. # : KW- 06006053 Description : (E) W10x33 [B8] 1 BEAM - -•s» -3 -6 -10 Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job# 11 -69335 Printed: 15 NOV 2011, 3:51PM e: Z :DatalStorage\ Cornerstone \Engineering1AT &T1_2011111 -69335 WA094 Tukwila ETC ICalcs \wa094 tukwila.ec6 ENERCALC, INC. 1983 -2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. 2.64 5.41 8.19 10.96 13.74 Distance (ft) • +1.410 • +1 2DD +D.SDL■+1.60L +1.60H • +1.20D +1.6DL +D.SD5 +1.6DH • +1.ZOD+1.60L. +D.SD6 ■ +1.200 +D.SOL +1.605 ■ +1.2DD +D.SDL. +D.5DL +1.6DW • +1.200 +D. S0L+D.655 +1.60W ■ +1.200 +5.131 +0.255• BEAM - - -s >_ 16.51 19.29 22.06 24.84 27.61 .0 2 -0.7 -1.0 -1.4 2.64 5.41 8.19 10.96 13.74 Distance (ft) IS 00.1y • LO•ly • 0 +6 16.51 19.29 22.06 24.84 27.61 ECoRNEFRs1rcNE E N G I N E E R I N G, I N C. project location by date sheet no. client checked date CEI job no. (E) w 10 no CM] CB ►63 Ctt&CK Woks)-- Act P EAAI (E) W I0 X 2 b EH] 1K\% WIDTN = (3t -6'') = l,s' pLi-LL = ('r Psi f 25 sn(L5') 22,5eff + 3-;S pJ4 W TELo SZa WrEtta = b`fo ?V' 6521 /1)1 LL : 2395 l.tif kt9 = S lb`t Idf 11.= Z3 95 lif W rrzo Wier° JI I Rg£ 1 W DL to— t,0,1 445 ' (1Au4h 1 l_ 0.L2Lf < to oK (9 Wlo )(i EB11 d Yf3(o] A-LE A9eciuATE Ta SLIPPPaT l'RDPfS D EQU ?Mt-NT CAgINCT. EiICOFINERS1rONE - ENGINEERING, INC. Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Steel Beam Lic. # : KW- 06006053 Description : (E) W10x26 [B9] Material Properties Analysis Method : Load Resistance Factor Design Beam Bracing : Beam bracing is defined Beam -by -Beam Bending Axis : Major Axis Bending Load Combination 2006 IBC & ASCE 7 -05 Unbraced Lengths _ Span # 1, Braced @ Mid Span D(6.521) L(2.385) Job # 11 -69335 3Z Printed: 15 NOV 2011, 3:55PM e Z:1 DatalStoragelCornerstonelEngineering \AT &71_2011111 -69335 WA094 Tukwila ETC\Calcslwa094 tukwila.ec6 ENERCALC, INC. 1983 -2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Calculations per AISC 360.05, IBC 2009, CBC 2010, ASCE 7 -05 Fy : Steel Yield : 36.0 ksi E: Modulus : 29,000.0 ksi D(0.02250 ) L(0.03750) 00.64) D(0.52) + + i + * * + * * + Applied Loads Beam self weight calculated and added to loads Loads on all spans... Partial Length Uniform Load : D = 0.02250, L = 0 Load for Span Number 1 Uniform Load : D = 0.520 k /ft, Extent = 6.083 - -» Uniform Load : D = 0.640 k /ft, Extent = 8.583 - -» Point Load : D = 6.521, L = 2.385 k 1.083 ft Point Load : D = 5.164, L = 2.385 k 16.083 ft DESIGN SUMMARY Maximum Bending Stress Ratio = Section used for this span Mu : Applied Mn * Phi : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward L +Lr +S Deflection Max Upward L +Lr +S Deflection Max Downward Total Deflection Max Upward Total Deflection + D(5.164) L(2.385) Span = 18.250 ft W1 OX26 Service loads entered. Load Factors will be applied for calculations. .03750 k /ft, Extent = 1.083 - -» 18.250 ft 8.583 ft, Tributary Width =1.0 ft 11.083 ft, Tributary Width = 1.0 ft 1,0.424:11 Maximum Shear Stress Ratio = W10X26 Section used for this span 35.797 k -ft Vu : Applied 84.510 k -ft Vn * Phi : Allowable +1.20D +0.50 Lr +1.60L +1.60H 9.490ft Span # 1 0.089 in Ratio = 0.000 in Ratio = 0.422 in Ratio = 0.000 in Ratio = Maximum Forces & S tresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # Load Combination Location of maximum on span Span # where maximum occurs 2462 0 <360 519 0 <180 Design OK 0.258 : W10X26 14.944 k 57.845 k +1 .20 D+0.50 L r +1.60 L +1.60 H 0.000 ft Span # 1 Summary of Moment Values Summary of Shear Values M V max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx +1.40D Dsgn. L = 9.13 ft 1 0.373 0.210 31.56 Dsgn. L = 9.13 ft 1 0.374 0.164 31.57 +1.20D+0.50Lr +1.60L +1.60H Dsgn. L = 9.13 ft 1 0.423 0.258 35.73 Dsgn. L = 9.13 ft 1 0.424 0.212 35.80 +1.20D +1.60L+0.50S +1.60H Dsgn. L = 9.13 ft 1 0.423 0.258 35.73 Dsgn. L = 9.13 ft 1 0.424 0.212 35.80 +1.20D +1.60Lr+0.50L Dsgn. L = 9.13 ft 1 0.352 0.205 29.76 Dsgn. L = 9.13 ft 1 0.352 0.163 29.78 +1.20D+0.50L +1.60S Dsgn. L = 9.13 ft 1 0.352 0.205 29.76 Dsgn. L = 9.13 ft 1 0.352 0.163 29.78 +1.20D+0.50Lr+0.50L +1.60W Dsgn. L = 9.13 ft 1 0.352 0.205 29.76 Dsgn. L = 9.13 ft 1 0.352 0.163 29.78 +1.20D+0.50L+0.50S +1.60W Dsgn. L = 9.13 ft 1 0.352 0.205 29.76 31.56 93.90 84.51 1.28 1.00 12.15 57.84 57.84 31.57 93.90 84.51 1.20 1.00 9.47 57.84 57.84 35.73 93.90 84.51 1.26 1.00 14.94 57.84 57.84 35.80 93.90 84.51 1.13 1.00 12.25 57.84 57.84 35.73 93.90 84.51 1.26 1.00 14.94 57.84 57.84 35.80 93.90 84.51 1.13 1.00 12.25 57.84 57.84 29.76 93.90 84.51 1.27 1.00 11.83 57.84 57.84 29.78 93.90 84.51 1.17 1.00 9.41 57.84 57.84 29.76 93.90 84.51 1.27 1.00 11.83 57.84 57.84 29.78 93.90 84.51 1.17 1.00 9.41 57.84 57.84 29.76 93.90 84.51 1.27 1.00 11.83 57.84 57.84 29.78 93.90 84.51 1.17 1.00 9.41 57.84 57.84 29.76 93.90 84.51 1.27 1.00 11.83 57.84 57.84 EIIICORNEFErUONE Steel Beam Lic. # : KW- 06006053 Description : (E) W10x26 [B9] Load Combination Segment Length Span # Dsgn. L = 9.13 ft 1 +1.20D+0.50L+0.20S+E Dsgn. L = 9.13 ft 1 Dsgn. L = 9.13 ft 1 Overall Maximum Deflections - Load Combination Max Stress Ratios Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 33 Printed: 15 NOV 2011, 3 55PM .e: Z:1 DatalStorage \CornerstoneIEngineering\AT&T1 _2011\11 -69335 WA094 Tukwila ETCICalcs1wa094 tukwila.ec6 ENERCALC, INC. 1983.2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. Summary of Moment Values M V max Mu + max Mu - Mu Max 0.352 0.163 29.78 0.352 0.205 29.76 0.352 0.163 29.78 Unfactored Loads Span Max. " -" Defl Location in Span Load Combination Summary of Shear Values Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx 29.78 93.90 84.51 1.17 1.00 9.41 57.84 57.84 29.76 93.90 84.51 1.27 1.00 11.83 57.84 57.84 29.78 93.90 84.51 1.17 1.00 9.41 57.84 57.84 Max. " +" Defl Location in Span 1 0.0000 0.000 Maximum Deflections for Load Combinations - Unfactored Loads Load Combination Span Max. Downward Defl Location in Span D Only L Only D+L 0.0000 0.000 1 0.3330 9.216 1 0.0889 9.490 1 0.4219 9.308 Vertical Reactions - Unfactored Load Combination Support 1 Overall MAXimum 11.510 D Only L Only D+L Steel Section Properties : Depth Web Thick = Flange Width = Flange Thick Area Weight = Kdesign K1 rts Ycg 37 27 18 BEAM--» 8.681 2.829 11.510 W10X26 10.300 in 0.260 in 5.770 in 0.440 in 7.610 in ^2 25.904 pif 0.740 in 0.688 in 1.580 in 5.150 in Support 2 9.348 6.763 2.584 9.348 Support notation : Far left is #1 Max. Upward Defl 0.0000 0.0000 0.0000 Location in Span 0.000 0.000 0.000 Values in KIPS I xx S xx R xx Zx I YY S yy R yy Zy rT 144.00 in ^4 27.90 inA3 4.350 in 31,300 in ^3 14.100 in ^4 4.890 inA3 1.360 in 7.500 inA3 1.540 in Cw Wno Sw Qf Qw 0.402 1n04 345.00 in ^6 14.200 in ^2 9.030 in ^4 5.980 inA3 15.400 inA3 1.73 3.56 5.38 7.21 9.03 10.86 12.68 14.51 16.33 18.16 Distance (ft) • +1.400 • +1.ZD0 +0.501. +1.60L +1.609 ■ +1.ZDD +1.60L +6.505 +1.609 • +1.200 +1.6DL" +D.SDL ■ +1.200 +0.5DL +1.665 D +1.20D +D.50L. +D.SDL.I.60W • +1.260 +0.501 +0.565 +1.65W • +1.200 +0.501 +D.205 - 15 1 BEAM - - -rr -6 -12 1.73 3.56 538 7.21 9.03 10.86 12.68 14.51 16,33 18,16 Distance (ft) • +1.4DD • +1.2D0a0.5Dl. +1.60L +1.609 • +1.200 +1.60L +0.505.1.659 • +1.260 +1.6DL, +D.50L • a1.20D +0.SDL +1.605 • +1.2DD+15.5DL. +D.SDL +1.60W • +1.200 +D.SDL +D.SDS +1.60W ! +1.200 +0.051+0.201. di EIIICORNERE1rONE ENGINEERING, INC• Title : WA094 Tukwila Dsgnr: TVL Project Desc.: Project Notes : Job # 11 -69335 Printed: 15 NOV 2011, 3 55PM Steel Beam Lic. # : KW- 06006053 Description : (E) W10x26 (B9] BEAK- r -0.11 Le .0.22 •0.32 .0.43 e: Z:1 DatalStoragelCornerstonelEngineering \AT &T1_2011\11 -69335 WA094 Tukwila ETC ICalcs\wa094 tukwila.ec6 ENERCALC, INC. 1983-2011, Build:6.11.9.30, Ver:6.11.9.30 Licensee : CORNERTSTONE ENGINEERING INC. 1.73 3,56 5.38 7.21 9.03 Distance (ft) ■ D O..1y • L O•ly • D +L 10.86 12.68 14.51 16.33 18.16 Project: WA094 Tukwila Date: November 16, 2011 Client: At &t Prepared By: T. Le t. CEI No.: 11 -69335 Page 35) References 1) Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineering (ASCE 7 -05), 2006 2) International Building Code (2009 IBC), International Code Council, 2009. 3) Manual of Steel Construction (ASD), American Institute of Steel Construction, Inc., 13th Ed., 2005. 4) Structural Engineering Library Version 6.11.9, EnerCalc Engineering Software, 2011. 16928 Woodinville- Redmond Rd NE, Suite 210 Woodinville, WA 98072 Email: cei @comerstone- engr.com Web: www.comerstone- engr.com CORNERS-If-ONE E N G I N E E R I N G , I N C. Phone: (425) 487 -1732 (206) 250 -7306 Fax: (425) 487 -1734 11 -01 -2012 City of Tukwila Jrm Haggerton, Mayor Department of Community Development Jack Pace, Director JENNIFER TAYLOR 7525 SE 24 ST, SUITE 500 MERCER ISLAND WA 98040 RE: Permit No. D12 -117 AT &T MOBILITY 16500 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/04/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/04/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, '3D,J) Bill Rambo Permit Technician File: Permit File No. DI2 -117 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 - 431 -3670 • Fax 206- 431 -3665 °PENT CO esen PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -117 DATE: 04 -05 -12 PROJECT NAME: AT &T MOBILITY SITE ADDRESS: 16500 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: •' • i ision q. L Public Works t Structural (' IL Fire Prevention n r� 1Ht Planning Division Permit Coordinator lit DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: otileiA2 Incomplete DUE DATE: 04-10 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route it Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 05 -08 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WREN CONSTRUCTION INC UBI No. 601925797 Phone 4252521282 Status Active Address 1410 80Th St Sw Ste A License No. WRENCI'013B6 Suite /Apt. License Type Construction Contractor City Everett Effective Date 1/26/1999 State WA Expiration Date 1/26/2014 Zip 98203 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WRENCI.0020K WREN COMM INC Construction Contractor Utilities And Telecommunications Unused 9/12/2000 1/7/2013 Active Business Owner Information Name Role Effective Date Expiration Date HAGY, DANIEL ERIK President 01/26/1999 Amount BONSEN, RANDY 11 01/01/1980 02/28/2012 BROIHIER, JEFF Agent 01/01/1980 02/28/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 DEVELOPERS SURETY a INDEM CO 521522C 01/26/2002 Until Cancelled $12,000.00 01/03/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 Alaska National Insurance Co 12EPS08393 05/01/2012 05/01/2013 $1,000,000.0005 /01/2012 10 WESTERN NATIONAL ASSUR CO CPP0014246 01/26/2010 01/26/2013 S1,000,000.0001/03/2012 9 WESTERN NATIONAL INS CP300008615 01/26/2008 01/26/2010 $1,000,000.00 01/07/2009 8 AMERICAN STATES INS CO 01CG109274 01/26/2006 01/26/2008 $1,000,000.00 01/15/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 05/15/2012 at &t Your world. Delivered. VICINITY MAP TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY WA094 GENERAL LOCATION MAP DRIVING DIRECTIONS FROM AT &T MOBILITY IN REDMOND: HEADING WEST ON SR -520 WEST TOWARDS SEATTLE. TAKE THE 1 -405 SOUTH EXIT TOWARDS RENTON. TAKE THE SOUTHCENTER BLVD EXIT TOWARDS SOUTHCENTER MALL. TURN RIGHT ON 61ST AVENUE S. TURN RIGHT ON SOUTHCENTER PKWY, ARRIVE AT 16500 SOUTHCENTER PKWY ON THE LEFT APPROVAL /SIGN OFF OF CONSTRUCTION DRAWINGS CONSULTANT GROUP SIGN OFF DATE SIGNATURE AT &T SIGN OFF DATE SIGNATURE CONSTRUCTION COORDINATOR SITE PLAN A -1.1 RF ENGINEER A -2 EXISTING & PROPOSED EAST ELEVATIONS LANDLORD'S REPRESENTATIVE EXISTING & PROPOSED WEST ELEVATIONS A -3 INTERCONNECT A -4 BATTERY SYSTEM REQUIREMENTS PROJECT MANAGER ELECTRICAL SCHEMATIC E -2 OPERATIONS E -3 ELECTRICAL & GROUNDING DETAILS SITE ACQUISITION COMPLIANCE ZONING CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED Goodman Networks REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of T ila BUILDING D VISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PROJECT INFORMATION APPLICANT: AT &T MOBILITY CORPORATION 16221 NE 72nd WAY, RTC 3 P.O. BOX 97061 REDMOND, WA 98052 PROJECT ENGINEER: CORNERSTONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD N.E. SUITE 210 WOODINVILLE, WA 98072 MARK W OLSON, P.E. PH: (425) 487 -1732 FAX: (425) 487 -1734 SEPARATE PE MIT r .QUIRED FOR: Mechanical Electrical Plumbing Gas Piping r of Tukwila DIVISi =: CODE INFORMATION: ZONING CLASSIFICATION: TUKWILA URBAN CENTER BUILDING CODE: IBC 2009 CONSTRUCTION TYPE: TELECOMMUNICATIONS OCCUPANCY: UNOCCUPIED JURISDICTION: TUKWILA PROPOSED BUILDING USE: TELECOMM SITE LOCATION: (BASED ON NAD 83) LATITUDE: 47 °27'15.36" N (47.4542) LONGITUDE: 122 °15'38.34" W (122.2606) TOP OF STRUCTURE: 104.T (BUILDING) BASE OF STRUCTURE: 33.4' AMSL PROJECT AREA: 60 SQ. FT. PROPERTY OWNER: CHA SOUTHCENTER LLC 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT CONSULTANTS: GOODMAN NETWORKS 8815 122ND AVE. NE KI RKLAN D, WA 98033 PROJECT MANAGER: MIKE MURRAY (214) 763 -1187 mmurray @goodmannetworks.com CONSTRUCTION MANAGER: DAVID BROOKS (214) 385 -3581 dbrooks @goodmannetworks.com SITE ACQUISITION / MANAGER: DERRICK PRIEBE (253) 219 -7127 derrick.priebe @telcopacific.com PARCEL NUMBER: 6437300020 AREA OF PARCEL: 291,927 SQ. FT. (6.7 ACRES) NEW IMPERVIOUS AREA: 0 SQ. FT. GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. (NON ASSIGNED TECH PARKING) 2. TRAFFIC IS UNAFFECTED. 3. NO SIGNAGE IS PROPOSED. PROJECT DESCRIPTION: THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF ADDING (2) BATTERY CABINET, AND (1) RECTIFIER INTO AN EXISTING POWER CABINET MOUNTED ON A EXISTING EQUIPMENT PLATFORM. PLANNING APPROVED No changes be made to these plans without approval from the Planning Division of DCD Approved By: � , ae ‘e'r . Date:, 96144-- PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT &T WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED. DRAWING INDEX DWG. NO. DESCRIPTION T -1 TITLE SHEET G -1 GENERAL NOTES A -1 SITE PLAN A -1.1 EXISTING & PROPOSED ENLARGED SITE PLANS A -2 EXISTING & PROPOSED EAST ELEVATIONS A -2.1 EXISTING & PROPOSED WEST ELEVATIONS A -3 EQUIPMENT DETAILS A -4 BATTERY SYSTEM REQUIREMENTS E -1 ELECTRICAL SCHEMATIC E -2 SCHEMATIC GROUNDING PLAN E -3 ELECTRICAL & GROUNDING DETAILS LEGAL DESCRIPTION OUTBACK STEAK HOUSE -BSP FILE COPY Permit Na VW-' Plan review approval b subject to errors and omissions Approval of construction documents does not authorizE the violation of any adopted code or orri'inance. Recap of approved f: Copy and conditions is admowledged By \AD Date., \\`: \L City Of BUILDING 1 = PROJECT CONSULTANTS: t) GoodmanNetworks = PLANS PREPARED BY: ff-� CORNERSTONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425,487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone-engr.com WWW.CORNERSTONE- ENGR.COM PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY ISSUED FOR: —REV: =DATE: CONSTRUCTION ISSUED FOR: Y: —DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.. APV.: I AJB I TVL CEI JOB NUMBER: ETC 11 -69335 I MWO I A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.. APV.: I AJB I TVL CEI JOB NUMBER: ETC 11 -69335 I MWO I 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: DRAWING NUMBER• TITLE SHEET 0 CEI JOB NUMBER: ETC 11 -69335 GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTORS SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND OWNERS PROJECT MANUAL. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER VERBALLY AND IN WRITING. 3. THE ARCHITECTS /ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT /ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'SNENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 6. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 7. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECTS SIGNED WET STAMP. 8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 -A OR 2 -A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 13. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS /CONTRACT DOCUMENTS. 14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNERS PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 15. THE CONTRACTOR SHALL PROVIDE AT &T WIRELESS, LLC. PROPER INSURANCE CERTIFICATES NAMING AT &T WIRELESS, LLC. AS ADDITIONAL INSURED, AND AT &T WIRELESS, LLC. PROOF OF LICENSE(S) AND PE & PD INSURANCE. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. 17. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. DIAL 811 18. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO AT &T WIRELESS, LLC. ALONG WITH REDLINED CONSTRUCTION SET. 19. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO AT &T WIRELESS, LLC. UPON COMPLETION. 20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK. 21. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 22. ANY SUBSTITUTIONS OF MATERIALS AND /OR EQUIPMENT, MUST BE APPROVED BY AT &T CONSTRUCTION MANAGER. 23. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND /OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTORS WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTO SIMULATIONS. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. GENERAL NOTES (CONT'D): 25. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND /OR ANTENNA FRAMES WHERE ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" - HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE PROVISIONS FOR X -RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 26. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON AT &T PROJECTS. RECOMMENDED MANUFACTURE SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S -CP UNDER SERIES -304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA. 1. DESIGN CRITERIA: THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2009 WITH WASHINGTON STATE BUILDING CODE AMENDMENTS (IBC 2009) 2. DESIGN LOADS: DESIGN DATA FOR CITY OF TUKWILA, WA: -ROOF SNOW LOAD -BASIC WIND SPEED -WIND EXPOSURE N/A (NOT A ROOFTOP SOLUTION) 85 MPH (3 SEC GUST) B CONCRETE NOTES: 1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI -318. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 19 OF THE IBC 2009. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. TYPE OF CONSTRUCTION A. SLABS ON GRADE TOPPING SLABS CONCRETE PIERS 28 DAY STRENGTHS W/C (fc) RATIO 3,000 PSI B. ALL STRUCTURAL CONCRETE 4,000 PSI EXCEPT WALLS C. CONCRETE WALLS 4,000 PSI CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O. MINIMUM CEMENT CONTENT PER CUBIC YARD • .45 5 1/2 SACKS • .45 6 1/2 SACKS .45 6 1/2 SACKS 3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. 4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR - ENTRAINED WITH AN AIR - ENTRAINING AGENT CONFORMING TO ASTM C260, C494, C618, C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE IBC 2009. 5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy= 60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy= 40,000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED. 6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH AC1 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2' -0 ". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2' -0 ". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -185. 8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy= 60,000 PSI. 9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT. 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: - FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE - FORMED SURFACES EXPOSED TO EARTH OR WEATHER ( #6 BARS OR LARGER) ( #5 BARS OR SMALLER) - SLABS AND WALLS (INTERIOR FACE) 11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. 12. ANCHOR BOLTS TO CONFORM TO ASTM A307. 3" STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL BE BASED ON THE A.I.S.I. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE WITH IBC 2009 CHAPTER 22, BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A. WIDE FLANGE SHAPE B. OTHER SHAPE, PLATES AND ROD C. PIPE COLUMNS D. STRUCTURAL TUBING E. ANCHOR BOLTS F. CONNECTION BOLTS ASTM A992, Fy 50 KSI ASTM A36, Fy 36 KSI ASTM A53, Fy 35 KSI ASTM A500, Fy 46 KSI ASTM A307 ASTM A325 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M -00. 5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.I. AND AWS STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. 6. COLD - FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD - FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.I. "SPECIFICATION FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS." 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" DIA.) AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 8. NON - STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A307 BOLTS UNLESS NOTED OTHERWISE. 9, ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN & CONSTRUCTION SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. 10. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE. 11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL. TOWER /POLE NOTES: 1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA LOADING IS TO BE DONE BY OTHERS. 2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS. ABBREVIATED ROOF TOP SAFETY PROCEDURES (WHEN APPLICABLE): (AS PER "ACCIDENT PREVENTION PROGRAM" - BY PERMISSION OF WREN CONSTRUCTION, INC. - 03/01/99) FALL PROTECTION METHODS AND EQUIPMENT ROOF TOP INSTALLATIONS 1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS. 2. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E., BACKING UP TOWARD A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION WORKERS. 3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE. 4. SAFETY LINE SHALL BE MINIMUM 1/2" DIAMETER NYLON, WITH A NOMINAL TENSILE STRENGTH OF 5400 LBS. 5. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE STRUCTURE. 2" 6. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO 1 1/2" REACH EDGE OF ROOF, BUT NOT BEYOND. 3/4" 13. NON - SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 PSI MINIMUM). 14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER. 7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS. 8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, INCLUDING: INSPECTION OF CONSTRUCTION AREA FOR HAZARDS USE OF AN INSPECTION CHECKLIST INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS REPORTING AND DOCUMENTING ANY HAZARDS REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER COWORKER SAFETY REPRESENTATIVE REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION REFERENCED OSHA REGULATION /STANDARDS SHALL BE REVIEWED BY TOWER ERECTORS, EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS /SUBCONTRACTORS 29 CFR 1926.500 - SCOPE, APPLICATION, AND DEFINITIONS 29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION 19 CFR 1926.502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES SYMBOLS AND ABBREVIATIONS NC AIR CONDITIONING AGL ABOVE GRADE LEVEL APPROX APPROXIMATELY BLDG BLK CLG CLR CONC CONST CONT DBL DIA DIAG DN DET DWG EA EL ELEC EQ EQUIP EXT FIN FLUOR FLR FS FT GA GALV GC GRND GYP BD HORZ HR HT HVAC ID IN INFO INSUL I NT IBC BUILDING BLOCKING CEILING CLEAR CONCRETE CONSTRUCTION CONTINUOUS DOUBLE DIAMETER DIAGONAL DOWN DETAIL DRAWING EACH ELEVATION ELECTRICAL EQUAL EQU IPMENT EXTERIOR FINISH FLUORESCENT FLOOR FAR SIDE FOOT GAUGE GALVANIZED GENERAL CONTRACTOR GROUND GYPSUM WALL BOARD HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING INSIDE DIAMETER INCH INFORMATION INSULATION INTERIOR INTERNATIONAL BUILDING CODE P T P COAX COAX . (E) LBS MAX MECH MTL MFR MGR MIN MISC NA NIC NS NTS POUNDS MAXIMUM MECHANICAL METAL MANUFACTURE MANAGER MINIMUM MISCELLANEOUS NOT APPLICABLE NOT IN CONTRACT NEAR SIDE NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER PLYWD PROJ PROP PT REQ RM RO SHT SIM SPEC SF SS STL STRUCT STD SUSP THRU TNNG TYP PLYWOOD PROJECT PROPERTY PRESSURE TREATED REQUIRED ROOM ROUGH OPENING SHEET SIMILAR SPECIFICATION SQUARE FOOT STAINLESS STEEL STEEL STRUCTURAL STUD SUSPENDED THROUGH TINNED TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/ W/O WP WITH WITHOUT WATER PROOF TELEPHONE POWER GROUND WIRE COAXIAL CABLE ANTENNA CENTERLINE EXISTING DETAIL NUMBER SHEET NUMBER REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION SPECIAL INSPECTIONS: SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2009 SECTION 1704. SOILS /GEOTECHNICAL: ❑ SHORING INSTALLATION AND MONITORING DOBSERVE AND MONITOR EXCAVATION ['VERIFY SOIL BEARING psf BEARING ❑SUBSURFACE DRAINAGE PLACEMENT ❑ VERIFY FILL MATERIAL AND COMPACTION ❑VERIFY CONDITIONS AS ANTICIPATED :PILE PLACEMENT (AUGER CAST /DRIVEN PILE) POTHER REINFORCED CONCRETE: ❑REINFORCING STEEL AND CONCRETE PLACEMENT D PRESTRESSED /PRECAST CONCRETE FABRICATION AND ERECTION ❑ BATCH PLANT INSPECTION ❑SHOTCRETE ❑GROUTING ❑OTHER STRUCTURAL STEEL: DFABRICATION AND SHOP WELDS DERECTION AND FIELD WELDS AND BOLTING ❑OTHER STRUCTURAL ALUMINUM: DFABRICATION AND SHOP WELDS ❑ERECTION AND FIELD WELDS AND BOLTING ❑OTHER STRUCTURAL MASONRY: DCONTINUOUS ❑PERIODIC OTHER: NONE REQUIRED ANCHORING TO CONCRETE: DBOLTS INSTALLED IN CONCRETE ❑POST- INSTALLATION ADHESIVE ANCHORS ❑POST- INSTALLATION MECHANICAL ANCHORS RECEIVED APR 05 2012 PERMIT CENTER at &t Your world. Delivered. PROJECT CONSULTANTS- -PLANS PREPARED BY: t) Goodman Networks _ CORNERS-I -ONE ENGINEERING. INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM :PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _REV: -DATE: CONSTRUCTION ISSUED FOR: Yi CHK.• -DRAWN BY: - CURRENT ISSUE DATE: _ LICENSURE: APV.: L L AJB I TVL I MWO I 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: ^^ "WING NUMBER: GENERAL NOTES G.1.1 0 CEI JOB NUMBER: ETC 11 -69335 A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB CHK.• -DRAWN BY: - CURRENT ISSUE DATE: _ LICENSURE: APV.: L L AJB I TVL I MWO I 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: ^^ "WING NUMBER: GENERAL NOTES G.1.1 0 CEI JOB NUMBER: ETC 11 -69335 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: ^^ "WING NUMBER: GENERAL NOTES G.1.1 0 CEI JOB NUMBER: ETC 11 -69335 iii THIS IS NOT A SURVEY ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND ARE APPROXIMATE. r TL# 5379200290 TL# 5379200282 ADJACENT ZONING ZONE: TUC TL# 5379200300 SOUTHCENTER PKWY SITE ACCESS TL# 2623049021 PROPERTY LINE 255.51'± N89 °45'58 "W ASPHALT PARKING PROPERTY LINE 197.67'± N89° 45' 58" W TL# 2623049104 ADJACENT ZONING ZONE: TUC +1 "'I�w IM wcr) z to N J >- o I- C O w 0 0 1 TL# 2623049102 1 PROPERTY LINE 350'± S89° 45' 58" E ASPHALT PARKING -- (E) NATIVE GRASS TL# 6437300020 II 1111111111111 1 co (E) ao BUILDING N w 111111111111111111111 TL# 2623049137 (E) BUILDING 1 \<6 \III111111111I1II1I1III11II1Y IMMO 11111111111111 I1111I11I1II1lfi ASPHALT PARKING PROPERTY LINE 407.84'± S89 °45'58 "E ADJACENT ZONING ZONE: TUC TL# 2623049128 (E) TREE (TYP) TL# 2623049005 ADJACENT ZONING ZONE: TUC REVIEWED FOR DE COMPLIANCE APPROVED City of Tukwila UILDING DIVISION TL# 2623049062 RECEIVED APR 05 2012 PERMIT CENTER PLAN NORTH SITE PLAN 22x34 SCALE: 1 " = 50' -0" 111x17 SCALE: 1" = 100' -0" — PROJECT CONSULTANTS: PLANS PREPARED BY: t) Goodman Networks CORNERS -GONE 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @comerstone-engr.com WWW.CORNERSTONE- ENGR.COM = PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _ REV:: DATE: CONSTRUCTION ISSUED FOR: —DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV IJ AJB I TVL I MWO I 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE —DRAWING NUMBER: SITE PLAN A...1 0 CEI JOB NUMBER: ETC 11 -69335 A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV IJ AJB I TVL I MWO I 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE —DRAWING NUMBER: SITE PLAN A...1 0 CEI JOB NUMBER: ETC 11 -69335 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE —DRAWING NUMBER: SITE PLAN A...1 0 CEI JOB NUMBER: ETC 11 -69335 bo 1)- 1111111111111111 111111111111111111111111111111111111111111111111111111111111111111 111 CV 0 N 0 L) (E) NOKIA CABINET (E) NOKIA CABINET (E) NOKIA CABINET (E) UMTS CABINET �• V 'J •V V \1 •.V �, \: V \v ,1' \t/ 111111111111111111111111111111 •11111111111 F •1 L4x4x1/4 L4x4x1 /4 FUTURE Y TE43 CABINET \ L- -_ UMW 1111UHI iiUii_ I ______ _M E+ MI f _iMiii fl uNuHH1 iii®i {= I iiitl inumi11Ii:::A -31 . . nunimuismiimmu E! iiitiUiminili lu _ r = - uuHuanii iiiuiil owiii il®irin®mm UIIUl®i_:: =:_ onorrormaromminvourome 1 Emmet! -' - -' -- iiimeimmiamemilmmumumniumumu mammon uminummirmiriliminuommiranuil ', ;_ :. � - -- (E) TE21 POWER CABINET 1 1 (E) EQUIPMENT PLATFORM (leo' 19' -8" 71 -0" RELOCATED STEP 27' -9" (E) ROOF MOUNTED COAX CABLE TRAY PROPOSED ARGUS TE40 BATTERY CABINET 4 ADD (1) RECTIFIER IN (E) ARGUS POWER CABINET PROPOSED ARGUS TE40 BATTERY CABINET (E) SERVICE LIGHT (E) SERVICE PANEL (E) TELCO BOX (E) XFMR PLAN NORTH I I I I I I I I I I I I I I 0 N 111111111111111111111111111111111111111111111 ,,V '1 w 111111111111111111111 1111111111111111111 1111 1111111 (E) NOKIA CABINET (E) NOKIA CABINET (E) NOKIA CABINET (E) UMTS CABINET FUTURE I TE43 CABINET L —� y -- 11 -8_ (E) EQUIPMENT PLATFORM U it 11 ° aa6 - oH�= : °HM =: =MOHLI (E) TE21 POWER CABINET ■1%1\11111111 4111 (E) ROOF MOUNTED COAX CABLE TRAY REVIEWED FOR CODE COMPLIANCE CE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION \l/ 1111111111 (E) STEP (TO BE RELOCATED) (E) SERVICE LIGHT (E) SERVICE PANEL (E) TELCO BOX (E) XFMR RECEIVED APR 05 2012 PERMIT CENTER PLAN NORTH at &t Your world. Delivered. =PROJECT CONSULTANTS: PROPOSED ENLARGED SITE PLAN 22x34 SCALE: 3/8" =11-0" 111x17 SCALE: 3/16" =11-0" EXISTING ENLARGED SITE PLAN 22x34 SCALE: 3/8" = 1' -0" 111x17 SCALE: 3/16" = 4Z) Goodman Networks PLANS PREPARED BY: _ -E COFINEFI51ONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone- engr.com WWW.CORNERSTONE- ENGR.COM PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY r: ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR: .J Y.■ CHK -DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: APV.: AJB 1 I TVL I MWO ETC 11 -69335 A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB CHK -DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: APV.: AJB 1 I TVL I MWO 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE DRAWING NUMBER. EXISTING & PROPOSED ENLARGED SITE PLANS A_ 1 ■ 1 CEI JOB NUMBER: ETC 11 -69335 bi 1 17 (E) ANTENNA MOUNT Li t:\ J \ ' C = - -- TOP OF (E) ANTENNA ARRAY PROPOSED ARGUS TE40 BATTERY CABINET / 4 \ 1 (E) ARGUS TE21 POWER CABINET EL 97' -2 "± TOP OF PENTHOUSE Akik EL 96' -4 "± TOP OF (E) PARAPET AL EL 82' -6 "± TOP OF (E) GRATING AL EL 78' -3 "± REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION TOP OF (E) ROOF AL EL 76' -0 "± GRADE EL 0' -0" (ASSUMED) PROPOSED EAST ELEVATION 22x34 SCALE: 3/32" = 1' -0" 111x17 SCALE: 3/64" = 1' -0" (E) ANTENNA MOUNT r (E) NOKIA CABINET (BEYOND) (E) UMTS CABINET TOP OF (E) ANTENNA ARRAY EL 97' -2 "± TOP OF PENTHOUSE (E) ARGUS TE21 POWER CABINET EL 96' -4 "± TOP OF (E) PARAPET AL EL 82' -6 "± Igr TOP OF (E) GRATING AL EL 78' -3 "± TOP OF (E) ROOF EL 76' -0 "± GRADE E101-0" (ASSUMED) RECEIVED APR 05 2012 PERMIT CENTER at &t Your world. Delivered. — PROJECT CONSULTANTS: — PLANS PREPARED BY: t) Goodman Networks CORN ERS1rONE ...._• ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone- engr.com WWW.CORNERSTONE - ENGR.COM = PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _REV: = DATE: EXISTING EAST ELEVATION 22x34 SCALE: 3/32" = 1' -0" 111x17 SCALE: 3/64" = 1' -0" 1 CONSTRUCTION ISSUED FOR: YJ :- CHK.. —DRAWN BY: — - CURRENT ISSUE DATE: _ LICENSURE: APV.: AJB I TVL I MWO 1 A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB CHK.. —DRAWN BY: — - CURRENT ISSUE DATE: _ LICENSURE: APV.: AJB I TVL I MWO 1 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: DRAWING NUMBER. EXISTING & PROPOSED EAST ELEVATIONS A-2 0 CEI JOB NUMBER: ETC 11 -69335 bui11 TOP OF (E) ANTENNA ARRAY EL 97' -2 "± PROPOSED ARGUS TE40 BATTERY CABINET (BEYOND) TOP OF PENTHOUSE EL 96' -4 "± TOP OF (E) PARAPET EL 82' -6 "± TOP OF (E) GRATING EL 78' -3 "± TOP OF (E) ROOF EL 76' -0 "± GRADE EL 0'-0" (ASSUMED) (E) ARGUS TE21 POWER CABINET (BEYOND) (E) NOKIA CABINET (E) ANTENNA MOUNT PROPOSED WEST ELEVATION 22x34 SCALE: 3/32" = 111x17 SCALE: 3/64" = 2 TOP OF (E) ANTENNA ARRAY EL 9T-2"± Li TOP OF PENTHOUSE I EL 96' -4 "± An TOP OF (E) PARAPET EL 82' -6 "± TOP OF (E) GRATING EL 78' -3 "± jik TOP OF (E) ROOF EL 76' -0 "± (E) ARGUS TE21 POWER CABINET (BEYOND) 7 GRADE EL 0'-0" (ASSUMED) (E) NOKIA CABINET (E) ANTENNA MOUNT == Jl REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION RECEIVED APR 05 2012 PERMIT CENTER EXISTING WEST ELEVATION 22x34 SCALE: 3/32" = 1' -0" 111x17 SCALE: 3/64" = 1' -0" 1 - PROJECT CONSULTANTS PLANS PREPARED BY: Goodman Networks _im_di CORNERS�'ONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone- engr.com WWW.CORNERSTONE- ENGR.COM = PROJECT INFO. WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR: Y: DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV.: I AJB I nit_ 0 I MWO J ETC 11 -69335 A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV.: I AJB I nit_ 0 I MWO J 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. -DRAWING TITLE: -DRAWING NUMBER: EXISTING & PROPOSED WEST ELEVATIONS r7 • 1 0 CEI JOB NUMBER: ETC 11 -69335 r7 at&t Your world. Delivered. F.— PROJECT CONSULTANTS: PLANS PREPARED BY: ci) Goodman Networks � COFRNERSN GONE ENGINEERI, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM = PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR:. .J Y._ I TVL BATTERY CABINET DIMENSIONS I MWO 2' -6" o MANUFACTURER ARGUS TE40 �' HEIGHT 84" 11 -30 -11 2' " ' ► DEPTH 30" 11 -16 -11 NOTES: AJB -0" WIDTH 30" 1. PLACE L4x4 SUPPORTS TO SUIT EQUIPMENT CABINET ANCHOR BOLT SPACING 2. FOR DESIGN OF THESE CONNECTIONS, PLEASE REFERENCE THE SUPPORTING STRUCTURAL CALCULATIONS BY CEI DATED 11/16/11 WEIGHT 3200 LBS o Q INTERNAL BUSS BAR CABINET GROUND WIRE STUDS ° 0 O O 0 ° ❑ ❑ ❑ J N L ❑ ❑ ARGUS TE40 CABINET (E) STEEL GRATING II 1 0 ❑ ❑ ❑ 0 ° 0 0 0 0 0 0 0 ° ° 0 ° ° ° a ° ° 5/8 "0 HOLES (TYP OF 4) DRILL AND INSTALL ANCHOR BOLTS PER MANUFACTURER'S RECOMMENDATIONS 1.10" 30.0" ENCLOSURE DIMS 27.80" 1.10" OR APPROVED EQUAL . �5���� mil 1/2"0 A307 BOLT (TYP OF 4 PER CABINET) ► ° ti o N ® \®►���� ®►t��5•\�►� ®�th� ® .■► 1 1 _ ° c� o w O 0 Iz 0 0 O O ° O O 0 0 IT ., I °` °I IpocI e I 4' -2 1/2" - N `t' N /// ��E ell� !�i p FIELD DRILL (2) 11/16"0 �' , N HOLES FOR 5/8 "0 A307 BOLTS, TYP EA END 1/4" L4x4 2" i 1 TYP ! (2) L4x4x1/4x0' -3" LONG (NS &FS) W/ (1) 5/8 "0 A307 BOLT, TYP 0 1 °a�) 0 IE.1 ° O - Q FRONT �._ .�AV ..�J�.®.=111 (E) W BEAM, TYP 3' -0" V.I.F. MOUNTING HOLE RIGHT SIDE VIEW LOCATION ARGUS TE40 BATTERY CABINET (24 V) 4 SUPPORT ANGLE DETAIL 3 22x34 SCALE: 1" = 1' -0" 111x17 SCALE: 1/2" = 1' -0" 22x34 SCALE: 1 1/2" = 1' -0" 111x17 SCALE: 3/4" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED MAY 152012 • City of Tukwila BUILDING DIVISION RECEIVED ti 05 2012 HERMIT CENTER NOT USED 2 NOT USED 1 22x34 SCALE: NTS 111x17 SCALE:. NTS 22x34 SCALE: NTS 111x17 SCALE: NTS at&t Your world. Delivered. F.— PROJECT CONSULTANTS: PLANS PREPARED BY: ci) Goodman Networks � COFRNERSN GONE ENGINEERI, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM = PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR:. .J Y._ —DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV.: AJB I TVL CEI JOB NUMBER: I MWO A 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: CURRENT ISSUE DATE: LICENSURE: CHK.: APV.: AJB I TVL CEI JOB NUMBER: I MWO 04 -03 -12 =DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: _DRAWING NUMBER: EQUIPMENT DETAILS A-3 0 CEI JOB NUMBER: ETC 11 -69335 Qua PROJECT BATTERY SYSTEM DATA BATTERY TYPE VALVE REGULATED LEAD ACID (VRLA) NO. OF BATTERIES 32 (8 EXISTING & 24 PROPOSED) BATTERY MANUFACTURER EXCIDE TECHNOLOGIES INDUSTRIAL ENERGY MODEL NO. MARATHON M12V155FT DIMENSIONS 22.0" D x 4.9" W x 11.15" H WEIGHT 119 Ibs PER UNIT # OF CELLS PER UNIT SPECIFIC GRAVITY LEAD WEIGHT PER CELL (Ibs) ELECTROLYTE WEIGHT PER CELL (Ibs) ELECTROLYTE VOLUME PER CELL (GAL) ELECTROLYTE VOLUME TOTAL (GAL) 1 1.35 90.4 21.4 2.17 73.78 BATTERY PLACEMENT: CSA/UL, TYPE 3R RATED, SELF - CONTAINED ENCLOSURE CABINET WITH ENVIRONMENTAL CONTROLS. ALPHA TECHNOLOGIES, LTD (20) BATTERIES PER CABINET. SHELF MOUNTED WITHIN MODEL# TE40B, MAX CAPACITY BATTERY REQUIREMENTS NONRECOMBINANT BATTERIES RECOMBINANT BATTERIES REQUIREMENTS FLOODED LEAD ACID BATTERIES FLOODED NICKEL - CADMIUM (Ni -Cd) BATTERIES VALVE REGULATED LEAD ACID (VRLA) BATTERIES LITHIUM -ION BATTERIES SAFETY CAPS N/A N/A v (608.2.2) N/A COMMENTS: PER MANUFACTURER, THE MARATHON M12V155FT UTILIZES A COMBINATION FLAME ARRESTOR / VENT CAP. THERMAL RUNAWAY MANAGEMENT N/A N/A (608.3) N/A COMMENTS: BATTERY IS MORE RESILIENT AS A RESULT OF THE LOW SPECIFIC GRAVITY DESIGN HOWEVER, ADDITIONAL DC POWER PLANT TEMPERATURE COMPENSATION MAY BE REQUIRED BY JURISDICTION. THERMAL RUNAWAY PROCEDURE ACTION SIGNAGE SHALL BE POSTED FOR EASY ACCESS IN ALL BATTERY AREAS. SPILL CONTROL N/A N/A (N /A) N/A COMMENTS: SPILL CONTROL NOT REQUIRED BY IFC FOR THIS TYPE OF BATTERY. NEUTRALIZATION N/A N/A (608.5.2) N/A COMMENTS: TOTAL ELECTROLYTE VOLUME IS UNDER REQUIRED SPILL CONTROL THRESHOLD, THEREFORE NO NEUTRALIZATION MEASURES REQUIRED. VENTILATION N/A N/A v (608.6.1;608.6.2) N/A COMMENTS: CONTINUOUS VENTILATION SHALL BE PROVIDED AT A RATE OF NOT LESS THAN 1 CUBIC FOOT PER MINUTE PER SQUARE FOOT (1 ft3 /MIN/ft2) AS NOTED IN IFC 608.6.1 NO. 2. ENVIRONMENTAL CONTROLS ASSOCIATED WITH PROPOSED ENCLOSURE HAVE BEEN SHOWN TO MEET REQUIRED CODE REQUIREMENTS. SIGNAGE N/A N/A AI (608.7) N/A COMMENTS: CODE SPECIFIED BATTERY ROOM SAFETY SIGNAGE, HAZARDOUS MATERIAL SIGNAGE (4 DIAMOND) AND THERMAL RUNAWAY PROCEDURE SIGNAGE SHALL ALL BE CLEARLY POSTED IN ALL BATTERY AREAS. SEISMIC PROTECTION N/A N/A Ai (608.8) N/A COMMENTS: BATTERY STORAGE ENCLOSURE CABINETS AND ANCHORAGE ARE DESIGNED TO EXCEED ALL IBC CODE REQUIRED SEISMIC FORCES FOR SITE SPECIFIC INSTALLATIONS. SMOKE DETECTION N/A N/A -Ni (608.9) N/A COMMENTS: N/A OUTDOOR APPLICATION NOTE: CODE REFERENCES ARE TO 2009 INTERNATIONAL FIRE CODE FOR STATIONARY STORAGE BATTERY SYSTEMS. CHEMICAL HAZARD IDENTIFICATION SYSTEM SPECIFIC HAZARD OXIDIZER ACID ALKALI CORROSIVE USE NO WATER RADIATION HAZARD OXY ACID ALK COR 4 - MAY DETONATE 3 - SHOCK & >HEAT MAY DETONATE 2 - VIOLENT CHEMICAL CHANGES 1- UNSTABLE IF HEATED 0- STABLE BATTERY HAZ MAT SIGN 22x34 SCALE: NTS 111x17 SCALE: NTS 3 THIS ROOM CONTAINS: LEAD -ACID BATTERY SYSTEMS, CORROSIVE LIQUIDS (ELECTROLYTE), ENERGIZED ELECTRICAL CIRCUITS, AND HYDROGEN GAS AUTHORIZED PERSONNEL ONLY EYE PROTECTION REQUIRED NO SMOKING OR OPEN FLAMES BATTERY ROOM REVIEWED FOR CODE COMPLIANCE APPROVED MAY 15 2012 City of Tukwila BUILDING DIVISION RECEIVED APR 05 2012 PERMIT CENTER BATTERY SYSTEM INFORMATION 22x34 SCALE: NTS I11x17 SCALE: NTS 2 BATTERY DANGER SIGN 22x34 SCALE: NTS I11x17 SCALE: NTS 1 at &t Your world. Delivered. — PROJECT CONSULTANTS: — PLANS PREPARED BY: Goodman Networks _-E CORNERS-II-GONE ENGINEERIN, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone- engr.com WWW.CORNERSTONE- ENGR.COM = PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR: .J Y.— —DRAWN BY: FCURRENT ISSUE DATE: _ LICENSURE: • CHK.. APV.: AJB 1 TVL CEI JOB NUMBER: I MWO e 11 -30 -11 CONSTRUCTION AJB A 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: FCURRENT ISSUE DATE: _ LICENSURE: • CHK.. APV.: AJB 1 TVL CEI JOB NUMBER: I MWO 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: _DRAWING NUMBER: BATTERY SYSTEM REQUIREMENTS A.4 0 CEI JOB NUMBER: ETC 11 -69335 b()II7 ELECTRICAL SPECIFICATION: 1. COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE, THE REQUIREMENTS OF ALL APPLICABLE MUNICIPAL AND STATE CODES AND REGULATIONS, AND UTILITY GUIDELINES. 2. PERFORM ALL VERIFICATION, OBSERVATIONS, TESTING AND EXAMINATION OF WORK PRIOR TO THE ORDERING OF ELECTRICAL EQUIPMENT AND THE ACTUAL CONSTRUCTION. ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE CONSTRUCTION MANAGER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40 CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARBON MANUFACTURER. COUPLINGS SHALL BE SLIP -ON SOLVENT SEALED T -PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT, ALL BENDS SHALL BE 30" MINIMUM RADIUS. 4. NEUTRAL SHALL BE COLOR CODED, INSULATION SHALL BE CROSS - LINKED POLYETHYLENE. 5. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES. SERVICE LOCATIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION. 6. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING, AND FEES IN CONJUNCTION WITH THE PROJECT. 7. THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH THE PROPER AUTHORITIES AND INFORM AT &T 24 -HOURS IN ADVANCE. ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE WITHIN 24 -HOURS AFTER THE INSPECTION HAS TAKEN PLACE. 8. ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL 9. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED JOURNEYMEN AND PERFORMED IN A WORKMANLIKE MANNER AND SHALL PROCEED IN AN ORDERLY MANNER SO AS NOT TO HOLD UP THE PROGRESS OF THE PROJECT. 10. THOROUGHLY TEST ALL LINES, FEEDERS, EQUIPMENT, AND DEVICES WITH MAXIMUM LOADS TO ASSURE PROPER OPERATION 11. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES 12. PROVIDE PULL BOXES WHERE SHOWN AND /OR WHERE REQUIRED BY CODES AND /OR UTILITY COMPANIES. 13. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS, CONTRACTOR SHALL VERIFY ALL LOCATIONS. 14. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J- BOXES, EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC TAGS. 15. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER. 16. ALL FIRE RATED WALL AND FLOOR PENETRATIONS ARE TO BE CAULKED AND SEALED WITH A FIRE RESISTANT CAULKING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION. 17. UTILIZE SONNEBORN TYPE NP -1 CAULKING FOR SEALING ALL EXTERIOR WALL PENETRATIONS 111 11 II1 1 11 1 1 1 1 I I I I I I I 1111111111111 1 1 11111 1I1 1I1I11I11 111111111111 II1 1 1 1 I 1 11 1 11 I1 I111111111I111111111111 1 1 1I 111 1 1 1 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1111111111111111 (E) NOKIA CABINET (E) UMTS CABINET (E) NOKIA CABINET PROPOSED ARGUS TE40 BATTERY CABINET (E) NOKIA CABINET (E) TE21 POWER CABINET 1 PROPOSED ARGUS TE40 BATTERY CABINET o�a�_��v1_ -I�N�� • L ��I�__ NNll�ldp�vi�p�d_b♦�__tl�N���b_f. NEN 11E-1191 (E) EQUIPMENT PLATFORM PROPOSED 1"f3 RIGID AC POWER CONDUIT MOUNTED ON UNDERSIDE OF (E) PLATFORM FROM UTILITY H -FRAME TO BATTERY CABINET (1) PER BATTERY CABINET PROPOSED 2 1/2"0 RIGID DC POWER CONDUIT MOUNTED ON UNDERSIDE OF (E) PLATFORM (1) PER BATTERY CABINET (E) SERVICE PANEL 111111111 PLAN NORTH ELECTRICAL SCHEMATIC 22x34 SCALE: NTS 111x17 SCALE: NTS 3 ROOFTOP PROPOSED UNDER PLATFORM MOUNTED 2 1/2 "0 RIGID DC POWER CONDUIT (1) TO EACH BATTERY CABINET PROPOSED BURIED 1" fa RIGID AC POWER CONDUIT FROM UTILITY H -FRAME TO BATTERY CABINET (1) TO EACH BATTERY CABINET (E) ELECTRICAL SERVICE PANEL / DISCONNECT (E) TELCO NIU (E) XFMR 1 1 . ., I PROPOSED ARGUS TE40 BATTERY CABINET (E) ARGUS TE21 POWER CABINET 1 ft I -' i i • .� i ��► I BA PROPOSED ARGUS TE40 BATTERY CABINET 1 w1_ 1 (E) UMTS CABINET (E) FLEX CONDUIT, TYP FUTURE TE43 CABINET I I 1 L___J 1 Li (E) NOKIA CABINET 1 (E) NOKIA CABINET 1 (E) NOKIA CABINET 1 (E) POWER & TELCO SERVICE PROPOSED FLEX CONDUIT, TYP (E) EQUIPMENT PLATFORM ,y 9a9tig�T *Q04451440 4�ECEIV APR 051012 PERMIT CENTER at&t Your world. Delivered. — PROJECT CONSULTANTS: 41:4 Goodman Networks _ PLANS PREPARED BY: � COFRNEFt3VONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY ISSUED FOR: _REV:: DATE: CONSTRUCTION ISSUED FOR: Y: —DRAWN BY: — CURRENT ISSUE DATE: _ LICENSURE: CHK.: APV.: 1 AJB I TVL I MWO I `EI JOB NUMBER: ETC 11 -69335 A 11 -30 -11 CONSTRUCTION AJB e 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: — CURRENT ISSUE DATE: _ LICENSURE: CHK.: APV.: 1 AJB I TVL I MWO I 04 -03 -12 —DRAWING INFORMATION: DRAWING TITLE. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. ELECTRICAL SCHEMATIC ELECTRICAL SPECIFICATIONS 22x34 SCALE: NTS 111x17 SCALE: NTS 2 POWER RISER SCHEMATIC 22x34 SCALE: NTS 111x17 SCALE: NTS 1 DRAWING NUMBER: 1)- 117 0 `EI JOB NUMBER: ETC 11 -69335 1)- 117 I I I I I I I I I I (E) NOKIA CABINET (E) NOKIA CABINET PROPOSED ARGUS TE40 (E) NOKIA CABINET in f E 11 El II__■:■MM __I__■MMIMMIWi■WMWMIMMItiv_■■__I_.I NEItl i y Iii { . mill::::::: 11! ri us um llim ; _ Ens ■■iii:_ ,�Il FM MI 11-- 111 (E) TE21 POWER CABINE7 i 7 PROPOSED ARGUS TE40 NOTE: ALL GROUNDING WIRE RUNS AND CONNECTIONS, BOTH ABOVE AND BELOW GRADE, SHALL BE LOCATED INSIDE OF THE LEASE AREA LINE. GROUNDING KEYED NOTES (E) GROUND BUSS BAR, TYP. (E) MAIN GROUND CONNECTION POINT. (V.I.F.) (E) GROUND LEAD. FIELD VERIFY & TIE INTO EXISTING BUILDING GROUNDING SYSTEM PROPOSED #2 STRANDED GREEN INSULATED GROUNDING WIRE, TYP. (E) #2 STRANDED GREEN INSULATED COPPER GROUND LEAD, TYP. (V.I.F.) PROPOSED GROUND BUSS BAR. SEE 9/E -3 PROPOSED GROUND LEAD. TIE INTO EXISTING BUILDING GROUNDING SYSTEM CABINET GROUND WIRE STUDS, SEE DETAIL 1/E -3 PROPOSED INTERNAL GROUND BAR. (INSTALLED BY EQUIPMENT MANUFACTURER) PROPOSED FLEX CONDUIT STRAIGHT CONNECTOR FOR GROUNDING CONNECTION TO INTERNAL GROUND BAR. GROUNDING NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. N 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND O THER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR PO LE FR' PRACTICES. USING MFR'S U 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN /THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT &T WIRELESS, LLC. REPRESENTATIVE. 5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT &T WIRELESS, LLC. REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. LEGEND GROUNDING ROD NOTES SYMBOL DESCRIPTION GROUND INSPECTION WELL COPPER GROUND ROD COMPRESSION LUG CADWELD CONNECTION SIDE SPLICE CADWELD FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM SCHEMATIC GROUNDING PLAN 22x34 SCALE: 1/2" = 1' -0" 111x17 SCALE: 1/4" = 1' -0" 1 ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTILIZING THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU. 2 POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE *ankle GRIDS AND EXISTING COMMUNICATIONS FACILITY. PERMIT AND APPROVAL REQUIRED RECEIVED APR 05 2012 PERMIT CENTER PROJECT CONSULTANTS: ti) Goodman Networks PLANS PREPARED BY: __E CORNERS-TONE ENGINEERING, INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY - ISSUED FOR: -REV: =DATE: CONSTRUCTION ISSUED FOR: rJ -DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.. APV.: AJB I TVL 1 MWO CEI JOB NUMBER: ETC 11 -69335 e A 11 -30 -11 CONSTRUCTION AJB A A 11 -16 -11 CLIENT REVIEW AJB -DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.. APV.: AJB I TVL 1 MWO 04 -03 -12 = DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. = DRAWING TITLE: SCHEMATIC GROUNDING PLAN .=DRAWING NUMBER: b t 7 CEI JOB NUMBER: ETC 11 -69335 b t 7 — PROJECT CONSULTANTS: — PLANS PREPARED BY: 4:11 GoodmanNetworks jCOPNEFI51rONE ENGINEERING. INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425,487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM =PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY E. ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR: .J MASTER GROUND BAR FACTORY INSTALLED IN THE LOWER LEFT COMPARTMENT I TVL oo ,_ � / �� #2 GROUND LEAD CONNECTED TO GROUND BAR WITH 2 -HOLE COMPRESSION LUGS ARGUS TE40 OR TE41 EQUIPMENT CABINET ENCLOSURE FACTORY INSTALLED EXTERNAL GROUND WIRE STUDS TO CONNECT GROUND LEAD AT THE BASE OF ENCLOSURE (TYP FRONT & BACK OF ENCLOSURE) CONTRACTOR TO PROTECT ALL EXPOSED SOLID BARE TINNED COPPER GROUND WIRE W/ 3/4 "0 FLEX CONDUIT STRAIGHT CONNECTOR FOR WATERTIGHT SEAL TYP. KNOCKOUT LOCATION TO SUIT SITE CONDITIONS GROUND BAR ATTACHMENT: NOTE: A o o 0 o 0 o a o 0 i r: CONCRETE SUBSTRATE: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS WITH 2" MINIMUM EMBEDMENT. WOOD FRAMED SUBSTRATE: (4) 3/8 "0 LAG SCREWS WITH 2" MINIMUM EMBEDMENT (ADD BLOCKING IF NECESSARY. COAT ALL MECHANICAL CONNECTIONS W/ "NO -LUX" OR APPROVED EQUAL WITHIN THE ENCLOSURE GROUND LEAD CONNECTED TO FACTORY INSTALLED GROUND WIRE STUDS WITH 2 -HOLE COMPRESSION LUGS (OPTIONAL @ FRONT OR BACK BASE OF EQUIPMENT CABINET ENCLOSURE) SOLID CMU WALL: (4) 3/8 "0 HILTI TZ EXPANSION HOLLOW CMU WALL: (4) 3/8 "0 HILTI HIT HY -20 WITH CLEAR HEAT SHRINK ON COMPRESSION LUGS ANCHORS WITH 2" MINIMUM EMBEDMENT. HIT -A STANDARD RODS. (3 3/8" EMBEDMENT) COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION W TYPE G INSTALL BY ANTENNA , ATTACH CONTRACTOR (CADWELD TO CLIENT REVIEW AJB O 0 J +�� \ \ _ 4 _ o g d. ' 0Af 0 0 o O O o 0 0 0 0 ' O 0 0 0 kl 0 0 0 0 o 0 0 0 0 0 0 0 o O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 O 7 0 ( �\ 24" O PROVIDE ELECTRICAL ISOLATORS @ �- 4"x 24"x 1/4" THK COPPER ` O GROUND BAR. INSTALLED CONNECTION (TYP) GROUND LEADS ROUTED TO EITHER GROUND BUSS BAR ( #2 STRANDED GREEN INSULATED COPPER) OR GROUND ,ii I BY GENERAL CONTRACTOR FIELD VERIFY // #2 SOLID BARE TINNED COPPER RING ( #2 SOLID BARE TINNED COPPER) WIRE CADWELD (TYPE -GL) ARGUS CABINET GROUNDING SCHEMATIC 1 1 GROUND BAR 9 22x34 SCALE: NTS 111x17 SCALE: NTS 22x34 SCALE: NTS 111x17 SCALE: NTS HYLUG CONNECTOR INSTALLATION INSTRUCTIONS: GROUND BAR ATTACHMENT: (E) POWER SOURCE CONTRACTOR TO MAKE ALL NECESSARY ARRANGEMENTS AND PROVIDE ALL REQUIRED LABOR AND MATERIALS TO OBTAIN A 200 AMP, 120/240, 10 3W SERVICE FROM EXISTING UTILITY PROVIDER. CONCRETE SUBSTRATE: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS WITH 2" MINIMUM EMBEDMENT. WOOD FRAMED SUBSTRATE: (4) 3/8 "0 LAG SCREWS WITH 2" MINIMUM EMBEDMENT (ADD BLOCKING IF NECESSARY. SOLID CMU WALL: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS WITH 2" MINIMUM EMBEDMENT. HOLLOW CMU WALL: (4) 3/8 "0 HILTI HIT HY -20 WITH HIT -A (3 EMBEDMENT) STANDARD RODS. 3 3/8" EMBEDMENT RECEIVED APR 052012 PERMITCENTER 1. SELECT PROPER HYLUG FOR THE WIRE SIZE USED. 2. STRIP CABLE OF INSULATION TO A LENGTH EQUAL TO THE BARREL OF THE CONNECTOR. 3. INSERT CABLE FULLY INTO CONNECTOR. 4. APPLY THE PROPER NUMBER OF CRIMPS AS SHOWN BY NUMBER OF COLORED BANDS. 5. CRIMP FROM TONGUE END OF CONNECTOR TOWARD CABLES FOR TERMINALS AND CENTER SPLICE TOWARD CABLE FOR BUTT SPLICES REQUIRING MORE THAN ONE CRIMP PER END. HYLUG TYPE YGA CONNECTOR IS PREFILLED WITH PENETROX COMPOUND AND STRIP SEALED. BURNDY HYDRAULIC DIE SET #U1CRT- 1 /U11T. #2 TW GREEN SERVICE ENTRANCE GROUND IN "0 (E) 200 AMP, 240V 10, 3W METER SUBBASE 3/4 CONDUIT TO (E) GROUND SYSTEM #2 TW GREEN SERVICE ENTRANCE GROUND IN "0 200A (E) 200 AMP, 240V 10, 2 P SERVICE ENTRANCE RATED FUSED DISCONNECT W/ 2-200 AMP TYPE CAPACITY (HRC) FUSES RUPTURING 3/4 CONDUIT TO (E) GROUND 200AF GROUND BAR ATTACHMENT 5 GROUND CRIMPING GUIDELINES 8 SYSTEM 22x34 SCALE: NTS 1 11x17 SCALE: NTS 22x34 SCALE: NTS 111x17 SCALE: NTS (2) 3/8 "0 SS HEXNUT �— Illllllllllllilllllp "'gym, ,��i Illilllliilllllllllllllllll �� IIIIIIIIIIilllllllllllllllll� (E) 200 AMP, 240V 10, 3W SERVICE PANEL W/ 200 AMP MAIN EQUIPMENT CHASSIS / GROUNDING BUSS BAR / ( #2) TWO HOLE COMPRESSION LUG �_ ! CABLE RACEWAY NO -LUX ANTI- OXIDIZING COMPOUND 3/8"0 STAR WASHER GROUND WIRE STUD , (TYP OF 2 @ FRONT - AND BACK F CABINET) •.• TYPE GR � Si 1: TYPE GL LUG �� #2 TW GREEN SERVICE ENTRANCE GROUND IN "0 • 200, 2P • BREAKER AND DISCONNECT CLEAR HEAT SHRINK ON I COMPRESSION LUGS ..._ �� . -,— 1.------ TYPE I��._�i��� ) � �• �;: PT .... SS 4Ir1I! •: •GROUND TYPE VS I r1 #2 STRANDED GREEN INSULATED COPPER GROUND LEAD TO BUSS BAR OR #2 SOLID BARE TINNED 3/4 CONDUIT 200, 2P 1 PER RECTIFIER IN ARGUS TO (E) GROUND POWER CABINET PLAN COPPER TO GROUND RING I SYSTEM 30, 2P HVAC IN ARGUS BATTERY TYPE GT TYPE I CABINET NOTE: _'- � 20, 1P LEADS ATTACHED TO EQUIPMENT CABINET AT GROUND WIRE STUDS LOCATED AT THE FRONT AND BACK OF CABINET BASE. FOR GROUNDING CONNECTIONS TO NO sitig CABINETS CHASSIS, GRIND OFF ALL ENAMEL COATINGS �+� :w y METAL AT LUG CONTACT AREA PRIOR TO MAKING BOLTE,' ,; D \1A CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE ME ,0‘ NOTE: ABOVE ARE EXAMPLES - CONSULT SPECIFIC TYPES OF CADWELDS CADWELD TYPES 11 SHOWN WITH PROJECT MANAGER FOR TO BE USED FOR THIS PROJECT. CADWELD DETAILS 4 ONE -LINE DIAGRAM 2 CABINET GROUNDING 22x34 SCALE: NTS 111x17 SCALE: NTS 22x34 SCALE: 6" = 1' -0" 111x17 SCALE: 3" = 1' -0" 22x34 SCALE: NTS 111x17 SCALE: NTS _ ,..st — PROJECT CONSULTANTS: — PLANS PREPARED BY: 4:11 GoodmanNetworks jCOPNEFI51rONE ENGINEERING. INC. 16928 WOODINVILLE - REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425,487.1732 FAX: 425.487.1734 EMAIL: cei @cornerstone - engr.com WWW.CORNERSTONE- ENGR.COM =PROJECT INFO: WA094 TUKWILA 16500 SOUTHCENTER PARKWAY TUKWILA, WA 98188 KING COUNTY E. ISSUED FOR: _REV: =DATE: CONSTRUCTION ISSUED FOR: .J —DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.: APV AJB 0 I TVL I MWO -3 AEI JOB NUMBER: ETC 11 -69335 A 1 11 -30 -11 CONSTRUCTION AJB it 11 -16 -11 CLIENT REVIEW AJB —DRAWN BY: CURRENT ISSUE DATE: _ LICENSURE: CHK.: APV AJB 0 I TVL I MWO 04 -03 -12 — DRAWING INFORMATION: DRAWING TITLE: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. ELECTRICAL & GROUNDING DETAILS DRAWING NUMBER: Dig J17 0 -3 AEI JOB NUMBER: ETC 11 -69335 Dig J17