Loading...
HomeMy WebLinkAboutPermit D12-119 - ATHWAL RESIDENCE - REROOF, SIDING AND DRYWALLATHWAL RESIDENCE 13543 35 AV S D12 -119 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8864000160 Address: 13543 35 AV S TUKW Suite No: Project Name: ATHWAL RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -119 Issue Date: 05/31/2012 Permit Expires On: 11/27/2012 Owner: Name: ARCH BAY HOLDINGS LLC Address: 400 NATIONAL WAY , SIMI VALLEY CA 93065 Contact Person: Name: JASPINDER ATHWAL Address: 20207 105 AV SE , KENT WA 98031 Contractor: Name: OWNER AFFIDAVIT - JASPINDER ATHWAL Address: Contractor License No: Lender: Name: Address: Phone: 206 - 919 -6882 Phone: Expiration Date: DESCRIPTION OF WORK: 1) NEW 7/16" OSB SHEATHING ON ROOF, FELT AND ARCHITECTURAL SHINGLES. 2) NEW 7/16" OSB SHEATHING FOR SIDING, FELT AND HARDIPLANK FIBER CEMENT LAP SIDING. 3) FINISH DRYWALL ON EXISTING FRAME IN LIVING ROOM, KITCHEN, LAUNDRY AND BATHROOM. R -13 INSULATION IN EXTERIOR WALLS Value of Construction: $4,000.00 Fees Collected: $439.63 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -119 Printed: 05 -31 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: ,11 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: astP iNincter Aitn wok Date: S— 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building doc: IBC -7/10 D12 -119 Printed: 05 -31 -2012 inspector. No exception. • • 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -119 Printed: 05 -31 -2012 CITY OF TUK Community DevelopmIlift Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Pe>iit No. p « (vi Project No. Date Application Accepted: 4' - Date Application Expires: 10-- VP' office use only) CONSTRUCTION PERMIT APPLICATION( y07r Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION `3.5t-A' 3S4' ( 2 wry Q R-1 6 $ King Co Assessor's Tax No.: ST 6 4 ooO \(O Site Address: X3 PNQ S , \v kUJ \ V.3A cl%031 Suite Number: Floor: Tenant Name: PROPERTY OWNER Company Name: `1 Q s9 AM1 W & Name: Aaso f\ 06.‘.Nri'1t)30.\ - Address: z020-1 joS V, p JQ se Address:2020 - t0 -\i'\ POP_ S c \ City: P_x1 State: wA Zip:gvo31 CONTACT PERSON - person receiving all project communication Company Name: `1 Q s9 AM1 W & Name: dQSp1 \der A'Ic I_ 1W0.I∎ Company Name: - Address: z020-1 joS V, p JQ se Zip:q $03 City: y.efes- State: wA Zip: ci r \ Phone: 206_alot— /o%_g'2 Fax: Address: Email: • \ p. o kh e_ c mai (. con-1 GENERAL CONTRACTOR INFORMATION Company Name: `1 Q s9 AM1 W & Address: 20-It, 20 1 I �5 A e_ Se Company Name: City: �2.(`c_ State: wp,, Zip:q $03 Phone:, _qlq_ bg.g.Z Fax: Contr Reg No.: Exp Date: Address: Tukwila Business License No.: H:\Applications\Forms- Applications On Line \20I2 Applications'Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh New Tenant: ❑ Yes EL. No ARCHITECT OF RECORD Name: Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required fo projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: ‘ob Page 1 of 4 BUILDING PERMIT INFORMATION — 206 - 431 -3670 co Valuation of Project (contractor's bid price : $ y I 000 Existing wilding Valuation: $ 1S %1 O 0� Describe the scope of work (please provide detailed information): Q Ni eu.) h os B Sheo.-{hin5 urn rot), 4e. \tt (IAA airck-e-VecAt404 SWn91es. 2Q New 7(tto OS ES Sheo--lh∎n9 -For gA.5 ke \--j a�A \-\ard■e_P ber- Cem Xv Lap Sidino�. 30 V■n■S■ dirkiVia\ of\ g `'co-)m2- \iv■n5 cc cr, 00.1ef1 ctkArNa.ni are A YooAlrvJrporA . R 13 insGdatin i e cien W- v`Al1S Will there be new rack storage? ❑ ....Yes X..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): (r7tk-A00 Floor area of principal dwelling: \, 100 5t f+ Floor area of accessory dwelling: 2q 0 St F+ *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm Compact: Handicap: No If "yes ", explain: None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicationaorms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 1 CA O 2nd Floor 3\0 3rd Floor Nyp Floors thru Basement NIA Accessory Structure* Attached Garage NfR Detached Garage 2q 0 Attached Carport N (A Detached Carport Nip, A Covered Deck N 7A Uncovered Deck N ( ps PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): (r7tk-A00 Floor area of principal dwelling: \, 100 5t f+ Floor area of accessory dwelling: 2q 0 St F+ *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm Compact: Handicap: No If "yes ", explain: None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicationaorms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: tee, a�.Q �aspi nclpr A rhtJoa.� 202o1 Ios1/` (cve Ste, H:Wpplications\Forms- Applications On Line12012 Applications\Fermit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Date: 3/A/ / l 2 Day Telephone: 2. 0(0 — q '?"$*-- WA 4E4331 City State Zip Page 4 of 4 PUBLIC WORKS PERMIT INF ATION — 206 - 433 -0179 Scope of Work (please provide detailed information): I.‘/ A • Water District ❑ .. Tukwila ❑ .. Water Availability Provided Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Septic System: ❑ On -site Septic System — For on -site septic sys - m, provide 2 copies of a current septic desi : approved by King County Health Department. ...Water District # 125 ❑... Highline ❑...Va y View ❑...Renton ❑ ... Sewe vailability Provided 0... Re on ... Seattle Submitted with Application (mark boxes which al) i ): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical eport ❑ .. Traffic Impact Analysis ❑ .. Bond ❑ ... Insurance 0... Easemen , s) ❑... Maintenanc Agreement(s) ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ... Righ of -way Use - Profit for less than 72 hours Ri t -of -way Use — Potential Disturbance Wor' 'n Flood Zone ... Storm ► ainage ❑ .. Sanitary Side Sewer ❑...Abandon Sep c Tank ❑... Grease Interceptor ❑ .. Cap or Remove Utilities 0... Curb Cut 0... Channelization ❑ .. Frontage Improvements 0... Pavemen Cut 0... Trench Excavation ❑ .. Traffic Control 0... Loope. ire Line 0... Utility Undergrounding ❑ .. Backflow Prevention - Fire Protection " Irrigation If Domestic Water ❑ .. Permanent Water Meter Size (1) " WO # (2) " WO # (3) ❑ .. Temporary Water Meter Size (1) WO # (2) " WO # (3) ❑ .. Water Only Meter Size WO # ❑ .. Deduct Water Meter ize ❑ .. Sewer Main Extension Public ■ Private ❑ ❑ .. Water Main Extension Publ. ❑ Private ❑ FINANCE INFORMATION " WO# " WO# Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. ewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 8864000160 Address: 13543 35 AV S TUKW Suite No: Applicant: ATHWAL RESIDENCE RECEIPT Permit Number: D12 -119 Status: APPROVED Applied Date: 04/06/2012 Issue Date: Receipt No.: R12 -01748 Payment Amount: $332.90 Initials: WER Payment Date: 05/31/2012 02:39 PM User ID: 1655 Balance: $0.00 Payee: JASPINDER ATHWAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03577C ACCOUNT ITEM LIST: Description 332.90 Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 328.40 640.237.114 4.50 Total: $332.90 doc: Receipt -06 Printed: 05 -31 -2012 fb City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 8864000160 Permit Number: D12-119 Address: 13543 35 AV S TUKW Status: PENDING Suite No: Applied Date: 04/06/2012 Applicant: ATHWAL RESIDENCE Issue Date: Receipt No.: R12 -01264 Initials: User ID: Payee: WER 1655 Payment Amount: $106.73 Payment Date: 04/06/2012 04:39 PM Balance: $332.90 JASPINDER ATHWAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03588B ACCOUNT ITEM LIST: Description 106.73 Account Code Current Pmts PLAN CHECK - RES 000.345.830 106.73 Total: $106.73 doc: Receipt -06 Printed: 04 -06 -2012 INSPECTION RECORD a copy with permit INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION.: 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - 36701' Permit Inspection Request Line (206) 431-2451 Project: IN V t..) A t, . 5 Type of Inspection: _ . I kl A L.,,, _ r C�jl Address: 135LI S60S Date Called: -� Special Instructions: PL, C3 O 7 C) Co'-i 7 _U� -o) Date Wanted 4 I t my P.m. Requester: Phone No J (. - 1 : -( S$,? © Approved per applicable codes. E3Corrections required prior to approval: COMMENTS: Oe ;T" &0 ILA rk Inspecto Date:. • n REINSPECTION FEE REQUIRED.IPrior to next inspection.-fee must be ".:;t: paid at 6300 Southcenter Blvd., Suite 100. Call.to schedule reinspection. - 1 INSPECTION RECORD Retain a copy with permit INSPELTION O. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: f i H tw} d11_ iz e S Type of Inspection: 1 tJ AL— Address: 135143 35 Au 5 Date Called: Special Instructions: 00Li(to `i—oZ Date Wanted:. 11 f 6 /iZ a.m. m: Requester: ` .J O e Phone No: .2O - C0837. 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ` .J O e t 2 (O C 1-? .. ( 2) NJ - l w( ' \J'- -_ A U 1 Inspector: _ ak_i?AA-11 Date: tii tr REINSPECTION FEE REQUIR €b. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PEWIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: Address: i 3S1-13 3S Au S Date Called: Special Instructions: Date Wanted:. 1 o -21-i-12 ;5.m' p.m. Requester: Phone No: ElApproved per applicable codes. COMMENTS: I. Corrections required prior;to approval. ) 14,A e_ AA i ZJP 2e,A4 0 i 1 L/-J -S ire) kf '4) /01J40.- f? &'& se e ,J'10 v r Chi ^ /t.C' A -Oro 4 ( ke sr- ce-; Insptctoor _ r -/' n REINSPECTION FEE REQUIRED -Prior to next inspection,. fee must be paid at 6300 Southcenter Blvd., Suite 100. Callto•schedule reinspection... Date:. /. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING ;DIVISION .:.: 6300 Southcenter Blvd., #100, Tukwila. WA 98188 .- (206) 43,1- 36.70` Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspetcti�j� Address: f i3s 43 35'N4' Date Called: Special Instructions: Date Wanted:i f (`� - :a.m. Requester: Phone No: (0 +. ( C� � i. Approved per applicable codes. Corrections required prior to approval COMMENTS: (kern -& Po M\ A 7 it Inspecto Date: REINSPECTION FEE REQUIRED. rior to next inspection.: fee: Must be."-. paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro e 1 ! Type of nspection:s - Address: 1 3543 3, .i�.. Date Calle &i. 7-L.- : r Special Instructions: ` Date Wanted:. ( °' m Requester: PhogeNo:(0 _n r5 L; Approved per-applicable codes. COMMENTS: Insprtor: l n REINSPECTION FEE REQUIRED. Prior to next inspection fee:must::be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: Corrections required prior to approval: Date- INSPECTION NO. INSPECTION RECORD Retain a copy with permit H5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Proje t: Type of In pection: Address: ,-,5-1 i S 1 3k✓E, Called: Special Instructions: Date Wanted:.. �._a,ms to n Requester: Phone No: N — 9(q - 652._._ Approved per applicable codes. Corrections required prior to approval. /G COMMENTS: A Date: r 0 1 . REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,O I I ( 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 x"_(206) 431 -36/0 Permit Inspection Request Line (206) 431 -2451 Project: ( T y (tv Address: 13 r‘4 3 71- .35 A-'/ Date Called: Special Instructions: \ i , � • Date Wanted _ /� i a.m. CP, Requester: Phone No� �(n I7 ff/ /j EjApproved per applicable codes. Corrections required prior to approval. Z COMMENTS: Nt.,,S J) tLef\‘4A471:-ef- Xcit REINSPECTION FEE REQUIRED. Prior to\next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit p12 --I(`. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 j (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj ctl'(1 n r Type of Inspection: tit) MI Address: _ 13513 3S 44 Date Called: ). -)Ve Al A-= Gn Gs Special Instructions: Date Wante 6 -(- -1 .mf ?Aim, p.m. Requester: - IZ/,I (f t Phone No. -- 1 tq - CO Z___ ElApproved per applicable codes. Corrections required prior to approval. i COMMENTS: 11.e. -.D(0 ). -)Ve Al A-= Gn Gs "-1n -P to eA n d S i (9t` -er), fre - IZ/,I (f t Inspect Date ri REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. b-- _r , INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1 o All-L Qi Auk Type of Inspection: RCeAOue Sru, W 'i Address:. /I5 .35 4v, Date Called: Special In tructions: Date Wanted:. ,,, aim: (/} rr�— 1 � P•m• Requester: ��tL��'' Phone e — I( (a Xta L.-•- Approved, per applicable codes. a Corrections required prior to approval. COMMENTS: Inspector: Da n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. I 541e2_'T- 2 ' S',eck- S • Colter Shy+ S � Plar Musty Ioor Plan\ Sine k_ 4 : SHoc Pty S hem S: De f u.cbe.ci Gc r-a f o r P lm-t\ • : S�� REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of u wiia BUILDING ISION u \Rwda TH Po:.rce -- 8?lok--kOo0 0o t \CO sct �-�- GC-roc! ; 2c\0 SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila 6U!LD:NG DIVISION MPs? FILE COPY Permit No., D12--I Plan review approval Is subject to errors and omIROnns. Approval of construction documents does not ai=thc, t the violation of any adopted code or ordinance. Ref, `pt of approved Field Copy and captions is acknowted ;3.i° By Date:, v S_ 31 —1 2- City Of Tukwila BUILDING DIVISION b12Il9 CORRECTION RECEIVED MAY 16 2012 PERMIT CENTER Sv►eek 1 6 6 I 35 Pac 3 3h" AV A \AA qS03 i5cg 000 Le Descx'1?-k-iof\ : Lo-k- b‘ocAc „ Vat P\88 Lko, P. 1.4 _ourrt 0.00 e(J\ SC0kke■ 01 \ZO1 SkruLciure_ Se Jr t3o too' REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2012 City of Tukwila BUILDING DIVISION 0 6,1 25' T Se 47- S RECEIVED MAY 16 2012 PERMIT CENTER 04 6 N7e RIua 2.0-{ ram.; r\ C'f n ���1 •New J , Q C 00 n 010+101c; i\V..r \ cL5u)ai\ DA exi six' A3 wgetls i1sL.la${o1 only) i ^ fix% watt S +nJ inflows . E xisk+..5 watts ZL, Xi 1 RtoQ 2oa£ -- 0 -711(,, osg shot ?n, nakte_d info eZ..+shn9 .Prone_ et 4 s+u to d ;nom os , w 3155'‘ (e s+b.pt.e s IS Ib5 foo�C�j P� ' S4\r•-c5- © 7(c(, OS' shectki,in9 ncx4A. e_ IS l bs . ktt Po.( -ee s}aetea 6•■\-12. c k40,-,14\04-,\(.. F00-er ij . j FLDOR '.\ REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 io Ity of Tukwila LDING DIVISION CE) 1 overhead tBea-11N (C) Kt= rc.hen (E) 0 Ce) k h JN N F LcOR. c3e� row (E) Ctoe1 CE) <` O gecJ roo ts (E) CVosei- j � \/ Zit 131 RECEIVED MAY 16 2012 PERMIT CENTER -LKITERIOQ: E2Sa New 2 x4 to.) oiv.4611 exi'cfo-,) (Ai -01-11— • 0 fflo\c-e Ako-.4-01 /0:1-rk:or, n x; AA 0-C1Y \ Carbon \ Mon oy■cl,•_ fr,laren \0 OOR A Zedroorr\ OF-) 3(4 XI 0 1 5coi.3 FLOOR. Ctos e+ Ja_ @_)e6reorn () REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED MAY 1 6 201Z PERMIT CENTER Lj C.IrIP,P+- G a1! an ex s , w4„S REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of Tukwila BUILDING DIVISION :?(1- C121021 Rooq - Q 111G (DS(- r1a.1e4 inh) e'K15•1'i19 i'-u�r41._ l�J iy ibs ratArn Ctilt S !e in hl ass w/ Ti? " S "S ,h ® Pc c_h e;-eL'hv l 0 1(t b o S t S tie a.K jn G na�ie 4 tn-15 2xCS'�+^c� 0 IS ■ b s let- ?ap -tr- sue, mod. into oS 3Ci liar cli P ! ank F- S ar • r CDA /1-'\C) j\ E Zut RECEIVED MAY 16 2012 PERMIT CENT rva Bedroom windows) EGRESS REQUIREMENTS R310.1 Emergency escape and rescue required. Basements with habitable space and every sleeping room shall have at least one operable emergency escape and rescue opening... Where emergency escape and rescue opening are provided they shall have a sill height of not more than 44 inches above the floor. R310.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet. Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet. R310.1.2 Minimum opening height 24 inches. R310.1.3 Minimum opening width 20 inches. R310.2 Window wells: minimum 9 square feet horizontal area...minimum 36 inches horizontal projection and width. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of Tukwila BUILDING DIVISION 7� s r c Th (6e8roomS hau 12, Scene e,fle 14S RECEIVED MAY 16 2012 PERMIT CENTER April 30, 2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jaspinder Athwal 20207 105 Ave SE Kent, WA 98031 RE: Correction Letter #1 Development Permit Application Number D12 -119 Athwal Residence —13543 35 Av S Dear Mr. Athwal, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. encl File No. D12-119 W:\Pennit Center\Correction Letters \2012012-119 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: Athwal Residence Permit #: D12 -119 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Plan shows using 'A" drywall (GWB). Minimum thickness required by code is 3/8" GWB. Typically Y2" GWB is used for wall and ceilings. Ceilings may require 5/8" or Y2" ceiling rated GWB. Revise plan to show GWB per code requirements. (IRC TABLE R702.3.5) 2. Wall insulation is indicated as R -13. Typically for existing construction with 2x4 exterior walls shall be required to have R -15 installed. Any new exterior wall construction shall be 2x6 framing with R- 21 insulation. Revise plan to show the R -15 over existing framing. Any new wall construction shall show R -21 insulation. 3. The second floor appears to be an existing loft area being converted to bedrooms by installing closets. The new bedrooms shall be required to meet code for a habitable space with the required head room and egress windows shall meet egress. Provide window size to show windows meet egress. Egress window shall have an opening of a minimum 5.7 sq. ft. 4. In addition to item 3), provide an elevation view of the second floor room that show ceiling heights with dimensions. Show bedroom width and show angled ceilings as well as short walls on the sides with all dimensions. Note: (Habitable space, hallways, bathrooms, toilet rooms, laundry rooms and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet. For rooms with sloped ceilings, at least 50 percent of the required floor area of the room must have a ceiling height of at least 7 feet and no portion of the required floor area may have a ceiling height of less than 5 feet.) (IRC R305.1) 5. Show each bedroom provided with smoke alarms. Outside the bedrooms and within close vicinity of the bedrooms smoke alarms and Carbon Monoxide alarms shall be installed. Show this on the plans. (IRC R314 & R315) Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. SERIN cum C PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -119 DATE: 05 -16 -12 PROJECT NAME: ATHWAL RESIDENCE SITE ADDRESS: 13543 35 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTpMENTS: u Ing Division Public Works Fire Prevention Structural n Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 05 -17 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IX Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-14 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • tiEtilIIIT Coin PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D12 -119 PROJECT NAME: ATHWAL RESIDENCE SITE ADDRESS: 13543 35 AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 04 -06 -12 Response to Correction Letter # Revision # After Permit Issued DEPA THE TS: ‘).■ ulldin Division Wr 14- Fire Prevention Structural Oil. 1-1 Planning" Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: tY Incomplete DUE DATE: 04 -10 -12 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route V Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 05-08-12 Not Approved (attach comments) 71 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg i.1 Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: S S— Plan Check/Permit Number: D12-119 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Athwal Residence Project Address: 13543 35 Av S Contact Person: JP Nil Phone Number: Zob – q Iq —6g $ - Summary of Revision: O DA3ww0L 1/4" g d3v.10, l site o1P-- uPS t"rS b2cLr000'‘ rliv`et\ (3 x L eleAta'hty -1 Vteeev Seenncl fruv■ SVke a(orW- / cex-60A itetoet oyCde, alarm. acj REED CITY OF TUKWILA MAY i1:.6 2U12. Sheet Number(s): 3,. t 5 Ca "Cloud" or highlight all areas of revision including date of revi "on e- Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 5--( PERMIT CENTER \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplanPci.tukwila.wa.us Permit Center /Building Division 206 431 -367o Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) 0,.S \ \C,-e4 [please print name] , states as follows: ci) PERMIT NO: cT 1 �� t tiki)_-o(01 --pc01)_- tot t. L__\)--- 03,19 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 'Z, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Signed and sworn to before me this 3 ( day of Cc v NO ARY PUBLIC in and for the State of Washington Residing at County Name as commissioned: -efr (-t v /' My commission expires: C)s "e71-9 ' /67 18.27.090 Exemptions. The regis n provisions of this P._ �� *4;.; 1. An authorized representative of the L tates government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed chapter do not apply to: • by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holdsa valid'electricalicontractor's license under chapter 1 288 RCWrthat employs a certified journeyman electrician; a,certified residential specialty electrician, or anelect`ricaltrainee meeting the requirements ofrChaptr 19.28 RCW toperform plumbing work that is incidentally, directly and,imnTediately appropriate to theslike;in - kind replacement of a household appliance or other sniallliousehold u'til'ization equipment that requires limited el`eetii4ower arid limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.