Loading...
HomeMy WebLinkAboutPermit D12-130 - CHASING FIREFLIES - PALLET RACKSCHASING FIREFLIES 1121 ANDOVER PK W EXPIRED 11 -07 -12 D12-130 City dtrukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049102 Address: 1121 ANDOVER PK W TUKW Suite No: Project Name: CHASING FIREFLIES DEVELOPMENT PERMIT Permit Number: D12 -130 Issue Date: 05/04/2012 Permit Expires On: 10/31/2012 Owner: Name: AMB PROPERTY CORP Address: 60 STATE ST STE 1200 C/O RE TAX , BOSTON MA 02109 Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98057 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET , RENTON, WA 98055 Contractor License No: NORTHWH275JF Lender: Name: Address: Phone: 206 - 818 -4488 Phone: 206 255 -0500 Expiration Date: 10/09/2013 DESCRIPTION OF WORK: INSTALLATION OF NEW AND USED PALLET RACKING. PLEASE SEE ATTACHED DRAWINGS, ENGINEERING AND SUPPLEMENT FOR BUILDING, SPRINKLER, COMMODITY AND LOCATION INFORMATION. Value of Construction: $0.00 Fees Collected: $1,215.02 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0025 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -130 Printed: 05 -04 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: pin Date: b I hereby certify that I have read and e • ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: C-741/( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, o:c if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 D12 -130 Printed: 05 -04 -2012 6: All construction shall be done in confor e with the approved plans and the require m! of the International Building Code or International Residential e, International Mechanical Code, Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 11: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 12: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 13: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 14: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Maintain fire extinguisher coverage throughout. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D12 -130 Printed: 05 -04 -2012 24: These plans were reviewed by Inspector X11. If you have any questions, please call Tukw re Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -130 Printed: 05 -04 -2012 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov _AP Building Permit No. bt) Project No. Date Application Accepted: Date Application Expires: (For office use. only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION L King Co Assessor's Tax No.: Site Address: ! i I 4 nd toes rL( �ZS! Suite Number: Floor: Tenant Name: C.—k4 S i nQ rire. 4-1/ t es PROPERTY OWNER `. Name: 4,4 5 City: 77 w / State: (/4 Zipp9 4-7 Address: i ._70 cridv.1442_1 Dr; 04 #e p0 1100 00 Sw 7 S% City: 7 k,,,,, is State: 1,j,er Zip18 L6 . CONTACT PERSON – person receiving all project communication Company Name:/ ,4/ Wes/ 74 //.,^ S Name: A// �reviS —•1 City: 77 w / State: (/4 Zipp9 4-7 Phone: ��`,a. '0S- Fax:tei.S a i G 1 ih ''ii 1100 00 Sw 7 S% Tukwila Business License No.: u S_ 6 g 9 304 7 City: •R r Ale) State: i4 Zip ues., 7 Phone: a06' cllg_ (pig? Fax: iii_sA '‘ 7 ,v6 Email: tr'1.Sorer, Son c r►k/4 S• CO o' , GENERAL CONTRACTOR INFORMATION Company Name:/ ,4/ Wes/ 74 //.,^ S Address: moo fiA/ (/ City: 77 w / State: (/4 Zipp9 4-7 Phone: ��`,a. '0S- Fax:tei.S a i G 1 ih ''ii Contr Reg No.: Exp Date: g Nc��,w% ��5�' lv qbo/3 Tukwila Business License No.: u S_ 6 g 9 304 7 H: \Applications \Forms - Applications On Line \201 1 Applications\Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh New Tenant: 'Yes ❑..No ARCHITECT OF RECORD Company Name:R P.os)f k- 6%Ag ` Engineer Name: ✓ Company Name: City: 6.(€414;6.. State: q Zip 9 /,U !� 7 Phone:g /g y0 gia Faxx1g 0 3Rl Architect Name: Address: City: State: Zip: Phone: Fax: Em.' . ENGINEER OF RECORD Company Name:R P.os)f k- 6%Ag ` Engineer Name: ✓ Address: to?. w 73_0,4,7 d y City: 6.(€414;6.. State: q Zip 9 /,U !� 7 Phone:g /g y0 gia Faxx1g 0 3Rl Email: LENDER/BOND ISSUED (required for projects greater per RCW 19.27.095) Name: Address: C. State: Zip: Page 1 of 4 • • BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ .3 , 006 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 2-4 s.4 f(4 f jc,.i o f nc( cis_ f Ge � cc( ((Q0 # St.Q Ge4r / �e c-. 4 c741. c•,a,, . �cr 6 44 Spy ��lLe�° (0,41,4,061 :47 /-y / L' l Will there be new rack storage? 12(ces E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: 1 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Pre Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1a Floor 1 (2°C) I ?-O0O -- 2 "d Floor - 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: 1 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Pre Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTJ J.7 TJ AGENT: Signature: Print Name: Date: y/i 9/0)-4' ��-- Day Telephone: a06 - 8i ce " G `f ge Mailing Address: ((be) Six/ 7 -§7 H: \ApplicationsWorms- Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -I I.docx Revised: August 2011 bh City %Sit)-S?' State Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.aov Parcel No.: 3523049102 Address: 1121 ANDOVER PK W TUKW Suite No: Applicant: CHASING FIREFLIES RECEIPT Permit Number: D12 -130 Status: APPROVED Applied Date: 04/20/2012 Issue Date: Receipt No.: R12 -01508 Payment Amount: $738.15 Initials: JEM Payment Date: 05/04/2012 01:59 PM User ID: 1165 Balance: $0.00 Payee: NORTHWEST HANDLING SYSTEMS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 292573 738.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 733.65 640.237.114 4.50 Total: $738.15 doc: Receiot -06 Printed: 05 -04 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO: PERMIT NO. •CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 k.IR. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 IL\42-/3 Project: ': r'?.Fr/ 7$ y /c; ,t- /-"r:ILf s Type of Inspection: 7:----, /1-7'/ L.. Address: / /e2 / r1Az) /c.,2 pe e.1,, Date Called: Special Instructions: � ��L % _ j /ii�'' / /r .r ? a p3s2/ -2ss3 C 96640 -0 / Date Wanted ::. !/r %/om a.m. . Requestera �li /tee Phone No: d6. - ;S/(° - .4/y92 ElApproved per applicable codes. E Corrections required prior to approval. 1 COMMENTS:.; C (24 Zei7O / /to-X , -- ,I-7'2€m )w Date: r•. . / REINSPECTION FEE REQUIRED. Prior o next inspection. fee must be paid at 6300 Southcenter Blvd Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -i3o PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: / GhGS,\,c, n+-e -i�r 1 frS . of Inspection: k4c,k F; ,,a, J Address: Suite #: I /)- I I hc:� 1c- Pk W Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: F o-c f;.„ 1 OI( Needs Shift Inspection: Al,,,, 3 ) 1 Sprinklers: Hrs.: Fire Alarm: Hood & Duct: Pre -Fire: /11//- Occupancy Ty6e: Monitor: % �/ Permits: N / Inspector: Al,,,, 3 ) 1 Date: .s -/i -/ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shot.crete Concrete Masonry December 21,2012 Asphalt Roofing P i l i n g S t e e l S o i l s File: 12 -310 W o o d A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND LIATERIAL TESTING NATIONALLY, ACCEPTED LABORATORY Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 C11419 LA OEC 2 62012 Project: Chasing Fireflies PERMIT CENT Address: 1121 Andover Park W. Permit No.: D12A30. This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report has already been forwarded to you. 1. Proprietary anchor installation To the .best of our knowledge all work inspected `conforrhed'to Tukwila Building Department'a,pproved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. v Aia Kimberle.Anderson President CC: NorthWest Handing Systems, Inc.- Mike.Sotenson Tel: (425) 881 -5812 Fax (425) 881 -5441 e 7126 180th Ave. NE* P.O. Box 2523* .Redmond, WA 9.8073 BY G. OHANIAN DATE 4-13-12 SUBJECT RAdK DEOI(N & ENdINEERINd do. 412 WEST BROADWAY, SUITE #204 dLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 1 JOB NO.. RD -16016 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: CHASING FIREFLIES 1121 ANDOVER PARK WEST TUKWILA, WA. 98188 PER IBC 2009 EDITION SECTION 2208 STORAGE RACKS CAPACITY: 3500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -16016 FILE COPY P rmft No.. EXPIRES 12 -26 -13 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 01 2012 City of Tukwila BUILDING DIVISION t• 130 RECEIVED APR 20 2012 PERMIT CENTER BY G. OHANIAN DATE 4 -13 -12 SUBJECT RACK DEOIG1N & EN(4INEERINd CO. 412 WEST BROADWAY, BUITE #204 OLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 2 JOB NO.. RD -16016 0 O FRONT VIEW BEAM SEISMIC DESIGN S pS X l V- _ Rx 1.4 Ix =1.63 Sx =.77 - F Y =55 KSI. SIDE VIEW LOAD PER BEAM + 25% IMPACT LOAD (4.0 Kx.88) +(2.0 Kx.25) = 4.0- 2.0 K 2 BEAMS M= 8 =21 "K SR= .64 <.77 4 A 384.1 L =.42 "< 180 =.53" x E xW IBC 2009 (SEC. 2208), RMI SPECS. ASCE 7 -05 (SEC. 15.5.3) S Os =0.94 (USGS WEB SITE, "SITE CLASS 0 ") 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED W =D.L.+ 3 PALLET LOAD LOAD PER COL. = 2x3.5 K =3.5 K 2 COL. P =.2 DL+ (3.5Kx0.75) =2.8K W =•2DL+ (3.4<1.x0.67)= 2.5 K \L= '28 K ONGIT. V = .42K TRANS. LONGIT. SEISMIC Conterminous 48 States 2009 International Building Code Latitude = 47.4442 Longitude = — 122.25790000000002 Spectral Response Accelerations SMs and SM1 SMs = Fax Ss and SM1 = Fv x S1 Site Class D — Fa = 1.0 ,Fv = 1.521 Period Sa (sec) (g) 0.2 1.403 (SMs, Site Class 0) 1.0 0.729 (SM1, Site Class 0) Conterminous 48 States 2009 International Building Code Latitude = 47.4442 Longitude = — 122.25790000000002 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D — Fa = 1.0 ,Fv = 1.521 Period So (sec) (g) 0.2 0.935 (SDs, Site Class 0) 1.0 0.486 (SD1, Site Class D) .28 K 9.9'K 6.5 -K 9.9 K BY G. OHANIAN RACK DE$I(N & ENdINEERIN(# CO. DATE . 4 -13 -12 412 WET BROADWAY, gUITE #204 SUBJECT LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 3 JOB NO. RD -16016 COLUMN ANALYSIS M 3" a 1I ' U , tt =.070" COMBINED STRESS RATIO Pex= (KE)12 = 18.0 ax =1 Pex .72 Fy =55 KSI Ae =.62 Ix =.95 Se =.6 rx =1.2 ry =1.1 Qc =1.8 Qb =1.67 Cmx =.85 BASE PLATE ANCH. TENSION = .25 K ANCHOR SHEAR - .14 K KL= 72x1.7 =102 rx 1.2 KL =1 =47 Y Mn =Se .Fy= 35 f2c.P + f2b.Cmx.M = .93 <1 Pn M, .ax (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT -TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 2 Fe =rr KLj2 =28 r 2 F n =F y(.658 c ) =24 KSI Pn= Fr, .Ae = 15 K 2.8K 9.9 ) I Q�� %- BASE PLATE I A c = N/Fy /Fe = 1.40 Ac<1.5 7 3/4 "x5 "x3/8" .5x.07x 1x65 =2.3 K BEARING CAPACITY OF COL. HOLE 6.5 "K 7/16 "0 RIVET A =.1 Fy =79KSI Pa = .1x79x.4 = 3 K 8.2-K Ma = (2.3'x4 ") +(1.1 Kx2 ") = 11.4 "K 3 PIN CONN. CONN. M END= • 01 )(WI 2= 1.6 "K M - _ 8.2 "K M= 9.8 K SEISMIC TOTAL 8.2 "K 9.9 "K 1 6" 7 3/4" BY G. OHANIAN RAdK DEOI(1N & EN(IINEERIN( do. DATE . 4 -13 -12 412 WET BROADWAY, QUITE #204 SUBJECT LEND• dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 4 JOB NO.. RD -16016 OVERTURNING MOT = .42'&2cxL170 "x0.66 =94 -K MR = 2.8 Kx44 "= 123 "K NO UPLIFT LOAD TO DIAGONAL P = .42 Kx2 x 58 = 1.1 K COL. 44 FY =55 KSI Ae =.26 rx =.48 Q =.74 L= 58" P° = 2.5 K CHECK WELDS P°= (1_.01L)L.t.F„ =5.36K 0= 2.55 = 2.1Kx2 = 4.2K SIDES CHECK SLAB 2800 =2 8 °' 1000 403 =20" .42K 2.8x144=403 °" 2 M= 1 ( 12 ) x1000x 2 x12 =666 "# S= 12x62 = 72 6 666 = 9 <1.6 V2500 =80 72 28K 28K I x L� \J 44" .42K n TOP LEVEL LOADING W= 0.2m+1.750 1.95K LOAD PER COL. V= .32 K MOT= .32Kx2 x144 = 92 "K COL. MR = 1.95K x44"= 86 "K UPLIFT = 92 "K -86 "K = ,13 44" BOTH SIDES TYP. t =.07" 2800 # 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL 10 -01 -2012 MIKE SORENSON 1100 SW 7 ST RENTON WA 98057 City of Tukwila Ji.m Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. D12 -130 CHASING FIREFLIES 1121 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/07/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 11/07/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenne - r tyLiv er Marshall t Technician File: Permit File No. D12 -130 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 NORTHWEST H A N D L I N G S Y S T E M S , I N C. The Material Handling Experts • FILE COPY Prir'ir Jt No. , 1100 SW 7th St Renton, WA 98057 (425) 255 -0500 ph (425) 228 -6946 fax ATTENTION FIRE AND BUILDING DEPARTMENTS RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1121 Andover PK W TENANT NAME: Chasing Fireflies DATE: April 19, 2012 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack and shelving configuration drawings attached. 2. Attached plans detail the rack /shelving locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Childrens clothing. Shirts, pants, dresses, coats. Made mostly of cotton and polyester. Stored in open top boxes or on wood pallets. 6. Sprinkler System Information: .39gpm/5600 sq. ft. Head temp: 165* 7. Smoke and heat vents: In place, as shown on site plan picture. 8. Building egress and exits indicated on attached drawings. 9. Emergency egress paths indicated on attached drawing. tso RECEIVED APR 20 2012 PERMIT CENTER POW GO COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -130 DATE: 04 -20 -12 PROJECT NAME: CHASING FIREFLIES SITE ADDRESS: 1121 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bu' Ildin> visiorY Public Works Fire Prevention Structural s Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -24-12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-22 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name NORTH WEST HANDLING SYS INC UBI No. 600051641 Phone 4252550500 Status Active Address 1100 Sw 7Th St License No. NORTHWH275JF Suite /Apt. License Type Construction Contractor City Renton Effective Date 4/6/1973 State WA Expiration Date 10/9/2013 Zip 980552939 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES JEROME President 01/01/1980 Amount KOSTY, CLARK RANDOLPH Treasurer 01/01/1980 4015483385 THOMAS, KEVIN A 10/01/2012 01/01/1980 09/28/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVS 81S103354822BCM 10/01/2001 Until Cancelled $12,000.00 10/09/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 31 CO ley Forge 4015483385 10/01/2011 10/01/2012 $1,000,000.00 09/27/2011 30 NATIONAL FIRE ADV4015483385 10/01/2010 10/01/2011 $1,000,000.00 09/20/2010 29 ACE AMERICAN INS CO PMDG24651605002 10/01/2008 10/01/2010 $1,000,000.00 09/30/2009 28 ACE AMERICAN INS CO PMDG23858769 10/01/2007 10/01/2008 $1,000,000.00 09/28/2007 27 ACE AMERICAN INSURANCE COMPANY PMDG22904279 11/01/2006 11/01/2007 $1,000,000.00 10/27/2006 26 BURLINGTON INS CO HGL0011190 11/01/2005 11/01/2006 $1,000,000.0011 /04/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 05/04/2012 EXPIRED NOV 02 2012 *- EGRESS PATH 5' -6" typ 54' CO rn CO CO CO CO CO CO CO CO 0) rn rn 0) 1' EGRESS PATH iO) CO x CO 0) CO 0) 0) CO 0) CO rn x CO r CO rn x CO CO 54' CO Q) CO v) x CO rn x CO 0) x CO 0) CO 0) x "4- d- CO rn x CO 0) x CO i CO 0) ! rn X 1 x CO CO CO 0) 1' CO CO 0) 0) CO 0) x CO 0) CO rn CO 0) x 0) CO 0) x �t- CO rn x CO 01 CO 0) x CO Co 16' — CO 0) CO rn x If CO 0) x, L----- ---- -J CO 0) x 0) x rn x �t- CO 0) CO C) x 1,11' 11' -8" EGRESS PATH EGRESS PATH 117 EF oLIDJ 144' 49' NORTH w 49' =PLAN VIEW SCALE: 3/32" = 1' -0" E1.77.) 50' NOV 01 2012 24' -9" 24' -7" 24' -7" 24' -7" 21'— 7) ,SETAr TiE PERMIT 1 Ui;RED FOR [i'ritedwical le ®'Plumbing 131/Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of 1 Tukwila Building Division. l `r T: 7.: %43!ofs will require a new plan submittal L may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 01 2012 v ty of Tukwila BUILDING DIVISION FILE COPY Permit No. Plan review approval is subject to errors and omissions. x p 3ry jai of construction documents does not authorize th volation of any adopted code or ordinance. Receipt of t.pproved Field Copy and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION SPECIAL INSPECTION FOR STORAGE RACKS (OVER 8 FEET) Periodic special inspection is required during the anchorage of access floors and storage racks 8 feet or greater in height in structures assigned to Seismic Design Category D, E or F. IBC 1707.5 and TABLE 1704.4 (4) Inspection of anchors installed in hardened concrete. RECEIVED APR 2 0 2012 PERMIT CENTER SHEET NUMBER 1 NOT PUBLISHED. ALL RIGHTS RESERVED. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTS REPRODUCED, COPIED, 0 a w 1- s 0 x w 3 III p J W N aJ 2 0 �w w r =o r ce o o_ °w o z tn N • a z o J O cn W u) a 1- O 0 a O w o 1- w D Z m L w o - o (1) w w 0 0 0 0 THEREBY ARE AND WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. LLI Oow < ZZ < Er 0 D Q vOww>- N0RTHWEsT w O O Cr 000 (1) °' o = I F- Q� N N (J)0in 0 z N .t 0 w RACK LAYOUT SHEET DESCRIPTION REVISIONS DRAWING NUMBER D -1 to 7 3/4" (2) -1/2 "0 ANCHOR BOLTS PER BASE PLATE 3 1/4" EMB., (SEE NOTE NO. 4) r e W • 4 1. 4. A. s • 4 d. • O 4 . • O r M a e BOTH SIDES TYP> 1/8 V1.5" 1 1/2" .� ,% 3/8 t =.06" SEC. A —A SEC. B —B 1/4"o SAFETY LOCK (1000 # CAPACITY) 7/16 "0 RIVET ASTM A576 -90B HOT— WROUGHT UNS G10100 GRACE C -1010 3 PIN CONNECTION ROW SPACER GENERAL CONFIGURATION N a) acv N N N \ \ 96" 1 u 4 10\ N N N L() 1 3 44" 3 r N N 1 44" 3 1 NOTES: EXP RSA) NOV 01, Z012 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 01 2012 City of Tukwila BUILDING DIVISION 1— DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2009 EDITION, SECTION 2208 2 —STEEL FOR ALL SHAPES FY =55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) 3 —NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #00777 (E70XX ELECTRODES) 4 —ALL ANCHORS HILTI KWIK BOLT —TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED 5— CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6— STORAGE RACK CAPACITY 3500 # /LEVEL 7 —RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE 3500 # /LEVEL 8— STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 1C-0" OF HEIGHT 9 —THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10— STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY 3 1 RECEIVED APR 20 2012 PERMIT CENTER RACK DESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 f DATE: 4 -15 -12 PROJECT: FRONT VIEW SIDE VIEW EXPIRES 12 -26 -13 CHASING FIREFLIES 1121 ANDOVER PARK WEST, TUKWILA, WA. STORAGE RACK DETAILS JOB RD-16016 SHEET NO. 1 OF 1