HomeMy WebLinkAboutPermit D12-143 - CORELINK - TENANT IMPROVEMENTCORELINK
3311 S 120 PL
STE 120
EXPIRED 11 -19 -12
D12-143
City oftukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 1023049069
Address: 3311 S 120 PL TUKW
Suite No:
Project Name: CORELINK
DEVELOPMENT PERMIT
Permit Number: D12 -143
Issue Date: 05/23/2012
Permit Expires On: 11/19/2012
Owner:
Name: SABEY CORPORATION
Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168
Contact Person:
Name: RANDY MORGAN
Address: 1326 FIFTH AV, SUITE 400 , SEATTLE WA 98101
Contractor:
Name: B N BUILDERS INC
Address: 2601 4 AV STE 350 , SEATTLE WA 98121
Contractor License No: BNBUII *990K3
Lender:
Name: CORELINK - SELF FUNDED
Address:
Phone: 206 - 587 -7120
Phone: 206 382 -3443
Expiration Date: 09/12/2013
DESCRIPTION OF WORK:
NON - STRUCTURAL INTERIOR TENANT IMPROVEMENT WORK: NON - STRUCTURAL DEMOLITION, NEW PARTITIONS, DOORS,
SUSPENDED UNI -STRUT GRID SYSTEM AND FINISHES.
Value of Construction: $24,500.00 Fees Collected: $937.25
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0008
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -143 Printed: 05 -23 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N • Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
Private:
Profit: N
Private:
N
Date:
Public:
Non- Profit: N
Public:
(ryS 11-$ 11
I hereby certify that I have read an ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be co . ied hether specified herein or not.
The granting of this per
construction or the p
to this permit.
Signature:
Print am :
of prey e to give authority to violate or cancel the provisions of any other state or local laws regulating
of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet
in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and
calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State
doc: IBC -7/10
D12 -143 Printed: 05 -23 -2012
of Washington.
•
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
doc: IBC -7/10
D12 -143 Printed: 05 -23 -2012
Code shall have letter widths, strokes and sing in proportion to their height. The word "F ' shall be in high
contrast with the background and shall be c1iery discernible when the exit sign illurninatio ans is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
24: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1
foot - candle (11 lux) and a minimum at any point of 0.1 foot - candle (1 lux) measured along the path of egress at floor
level. Illumination levels shall be permitted to decline to 0.6 foot - candle (6 lux) average and a minimum at any point
of 0.06 foot - candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination
uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4)
25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327).
29: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and
City Ordinance #2328.
30: Local U.L. central station supervision is required. (City Ordinance #2328)
31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2328)
32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC
104.2)
33: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
34: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and
#2328)
37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IBC -7/10
D12 -143 Printed: 05 -23 -2012
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http: / /www.TukwilaWA.gov
Building Permit No.
143
Project No.
Date Application Accepted: 4--)77
Date Application Expires: 10--y77 - -
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address:
King Co Assessor's Tax No.: 102304 - 9078 -05
3311 South 120 Place Tukwila, WA 98168
Tenant Name: Corelink
Suite Number: 120 Floor: 1st
PROPERTY OWNER
Name: Sabey
Address: 12201 Tukwila International Blvd., Ste 400
City: Tukwila State: WA Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Randy Morgan
Address: 1326 5th Avenue, Suite 400
City: Seattle State: WA Zip: 98101
Phone: (206) 587 -7120 Fax: (206) 587 -7122
Email: randym @burgessdesign.net
GENERAL °CONTRACTOR- INFORMATION
Company Name: TBD t9ly �� t `ek oAx(
°
Address: n 1 , 4 p, r/ �
�,[ l/'
City: State: - f Zip: libill
Phone: Fax:
Contr Reg No.: yl n 1 1 / Oj clt Date: al
I J
6
Tukwila Business License No.: rJIA,I — og1li.1i Y
H:\Applications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 1I.docx
Revised: August 2011
bh
New Tenant: ❑ Yes ..No
ARCHITECT OF RECORD
Name:
Company Name: Burgess Design
D
Architect Name: Randy Morgan
Address:
Address: 1326 5th Avenue, Suite 400
City: Seattle State: WA
Zip: 98101
Phone: (206) 587 -7120 Fax: (206)
587 -7122
Email: randym @burgessdesign.net
ENGINEER OF RECORD
Company Name:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND:ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
"5 E. _ F-1.)
D
Address:
City:
State:
Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION - 206 - 431 -3670
•
Valuation of Project (contractor's bid price): $ Zi4 /09'
Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
Non structural interior tenant improvement work; non - structural demolition, new partitions, doors, suspended uni -strut grid system
and finishes.
Will there be new rack storage? ❑ Yes
Z.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers Automatic Fire Alarm None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Wpplications\Forms- Applications On Line\2011 Applications\Permit Application Revised - 8 -9 -1 I.docx
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
l't Floor '
22,069
2,150
0
0
VN
B
2nd Floor
3rd Floor
Floors thru
Basement
Accessory ' Structure*
Attached Garage
Detached Garage
Attached Carport
Carport
Covered Deck
:Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers Automatic Fire Alarm None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Wpplications\Forms- Applications On Line\2011 Applications\Permit Application Revised - 8 -9 -1 I.docx
Revised: August 2011
bh
Page 2 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no, permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more ex nsions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable demons rated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I AD AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY E L S OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 1 • 1;,!il• D AGE
Signature:
Print Nam`'' uy urban Day Telephone:
Mailing Address: 1326 5th Avenue, Suite 400 Seattle WA 98101
Date: 04/27/2012
H:\Applications\Forms- Applications On Line \2011 Applications'Permit Application Revised - 8 -9 -I I.docx
Revised: August 2011
bh
City State Zip
Page 4 of 4
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 1023049069
Address: 3311 S 120 PL TUKW
Suite No:
Applicant: CORELINK
RECEIPT
Permit Number: D12 -143
Status: APPROVED
Applied Date: 04/27/2012
Issue Date:
Receipt No.: R12 -01670
Payment Amount: $569.80
Initials: JEM Payment Date: 05/23/2012 03:46 PM
User ID: 1165 Balance: $0.00
Payee: BURGESS DESIGN, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 011454 569.80
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 565.30
640.237.114 4.50
Total: $569.80
doc: Receiot -06 Printed: 05 -23 -2012
1 •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 1023049069
Address: 3311 S 120 PL TUKW
Suite No:
Applicant: CORELINK
RECEIPT
Permit Number: D12 -143
Status: PENDING
Applied Date: 04/27/2012
Issue Date:
Receipt No.: R12 -01452
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $367.45
Payment Date: 04/27/2012 02:50 PM
Balance: $569.80
BURGESS DESIGN INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 011378 367.45
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 367.45
Total: $367.45
doc: Receiot -06 Printed: 04 -27 -2012
10 -01 -2012
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
RANDY MORGAN
1326 FIFTH AV, SUITE 400
SEATTLE WA 98101
RE: Permit No. D12 -143
CORELINK
3311 S 120 PL TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 11/19/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 11/19/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall
t Technician
File: Permit File No. DI2 -143
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -.3670 • Fax 206-431 -3665
41kEllirt
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -143 DATE: 04 -27 -12
PROJECT NAME: CORELINK
SITE ADDRESS: 3311 S 120 PL, SUITE 120
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
EPARTMENTS:
ui ding 'vision
Public Works
P �l I� or. ( v�
Fire Prevention Planning Division
Structural
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 05-01 -12
Complete Incomplete Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined Incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route 41 Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 05-29-12
Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
• Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople liter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name B N BUILDERS INC UBI No. 602056687
Phone 2063823443 Status Active
Address 2601 4Th Ave Ste 350 License No. BNBUII`990K3
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 5/23/2001
State WA Expiration Date 9/12/2013
Zip 98121 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
ther Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
WESTESL913K1
WESTERN STATES
LOGISTIX LLC
Construction
Contractor
General
Unused
5/8/2009
5/8/2013
Active
BASTINB0000J
BASTIAN NIELSEN
BUILDERS INC
Construction
Contractor
General
Unused
9/11/2000
9/7/2001
Archived
PURODSI984JN
PURODI SYSTEMS
INC
Construction
Contractor
Plumbing
Unused
6/19/2002
7/2/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
BASTIAN, BRADLEY JAMES
President
05/23/2001
Bond Amount
NIELSEN, JEFFREY J
Vice President
05/23/2001
6642084
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
INS CO OF
AMERICA
6642084
06/02/2009
Until Cancelled
$12,000.00
06/05/2009
4
HARTFORD FIRE INS
52BSBBK5617
01/01/2002
Until Cancelled
06/02/2009
$12,000.00
12/04/2001
3
TRAVELERS CAS 8
SURETY CO
103355900
08/30/2001
Until Cancelled
04/07/2009
$12,000.0009/06
/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
13
Zurich
American Ins Co
GLA380504401
09/07/2011
09/07/2012
$1,000,000.00
09/01/2011
12
ZURICH
AMERICAN INS
CO
gla380504400
09/07/2010
09/07/2011
$1,000,000.00
09/07/2010
11
WAUSAU
UNDERWRITERS
INS. CO
TBJZ91442966029
09/07/2009
09/07/2010
$1,000,000.0009
/03/2009
10
WAUSAU
BUSINESS INS
CO
TBKZ91442966028
09/07/2008
09/07/2009
$1,000,000.0009
/05/2008
https://fortress.wa.gov/lni/bbip/Print.aspx
05/23/2012
GENERAL NOTES
ARCH INTERIOR ABBREVIATIONS B
BUILDING SUMMARY P
PROJECT TEAM
1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING A
ADJ - ADJUSTABLE MECH - MECHANICAL 1
1. PROJECT ADDRESS: T
TENANT: GENERAL CONTRACTOR:
LEGAL DESCRIPTION / PARCEL NO.
E
LEGAL DESCRIPTION:
°9-+ C
102304 - 9078 -05 R
REVIEWED FOR
STREET MAP D
DRAWING INDEX
P
\ DRAWING ISSUED
DATE ,
04.25.12
�
GENERAL
G.0.0 COVER SHEET / PROJECT INFORMATION
X G
G.0.1 PROJECT NOTES
X G
G.0.2 SITE PLAN W
X G
G.0.3 CODE SUMMARY
ARCHITECTURAL 1 INTERIORS
`" A
A.2A.1 DEMOLITION & CONSTRUCTION/ POWER & DATA /
% `
FINISH FLOOR PLANS
q 4124±7 ;
; A
A.26.1 REFLECTED CEILING PLANS
X A
A.9.1 DOOR SCHEDULE / DETAILS
� X
A S
• .
c/>
S N
N •
ARCHITECT WILL D
T
DEFINITIONS AND DIMENSIONS K
KEY PLAN / FLOOR PLATE - 1 ":50'
PLANNING �..._., '
A. DEFINITIONS: I
INTERGATE EAST • • • EXIT EXIT EXIT ALL EXITS ARE EXISTING
■rini ■+n Q D erg
B
BUILDING 2 ■
'
COPY
Date: • SU 3
_ FILE C
= n
SYMBOLS .
�`7 Dt L-
.
-�
to sum
�� t
SUITE 160 �
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design I interiors e architecture
1326 Fifth Avenue Suitt 500. Seattle . WA 98101 111: 206.587.7120 FAX:206. 587.1127
All reproduction & intellectual property rights reserved c 2012
Approved by: Date:
CONSTRUCTION WORK SHALL NOT PROCEED UNTIL
THE BUILDING OWNER / REPRESENTATIVE AND
BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO
THESE CONSTRUCTION DOCUMENTS. APPROVAL BY
THESE PARTIES SHALL BE INTERPRETED AS
APPROVAL OF DRAWINGS FOR CONTENT, FINISH
SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS
REGARDED BY EITHER PARTY AS BEING NECESSARY
TO THEIR OPERATIONS, USE OF THE SPACE,
FURNISHINGS, AND TENANT EQUIPMENT AND
FURNITURE INSTALLATIONS.
CONSTRUCTION AND /OR INITIATION OF
CONSTRUCTION, AUTHORIZED BY THE BUILDING
OWNER FROM THESE CONSTRUCTION DOCUMENTS,
SHALL BE INTERPRETED BY THE DESIGNER AS
APPROVAL IN FULL OF THESE CONSTRUCTION
DOCUMENTS BY BOTH THE BUILDING OWNER /
REPRESENTATIVE AND THE TENANT.
Professional seal
No. Issue Description
Date
PERMIT SET 04.25.12
and *lesions.
does not auutbcrize
o��inance. Receipt
I adanowiedged:
ON
Drawn by: MK
Project No: 12.SB13.00
Reviewed by: RM
COVER SHEET /
PROJECT INFORMATION
Original drawing is 24" x 36•'. Scale entities accordingly if reduced
G.0.0
PROJECT NOTES
1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION
ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY
WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION
RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS.
2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD
CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE
AND SCHEMATIC DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY
REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS
FOR AESTHETIC REASONS ONLY.
3. VERIFY BUILDING STANDARDS WITH BUILDING MANAGEMENT WHEN WORKING IN SUITES WITH NON BUILDING
STANDARD ELEMENTS. VERIFY PREFERRED DETAILING OF THESE ELEMENTS WITH BUILDING MANAGEMENT.
4. VERIFY ALL RULES, GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING
MANAGEMENT.
5. VERIFY LEED REQUIREMENTS WITH BUILDING MANAGEMENT.
DMSION I - GENERAL CONDITIONS
01010 SUMMARY OF WORK
1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A
COMMERCIAL OFFICE SUITE, UON.
2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE
PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S
RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS.
3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED
BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS
RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE
TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE.
4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE
EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN
PLACEMENT.
5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR.
6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE
SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT),
SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES.
7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES.
FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS,
AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS.
8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL
KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED.
9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS.
10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING
SHELL STANDARD SPECIFICATIONS.
11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF
CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE
OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL
MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES.
12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO
FINISHED FACE UNLESS OTHERWISE NOTED.
13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS
RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND
QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL, EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY
WITH ALL PROPER JURISDICTIONAL APPROVALS.
DMSION II - Sfl E WORK
02050 - DEMOLITION
1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND
REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION
WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN.
2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO
ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES
BELOW.
3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES
SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY.
4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE
PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN
CEILING, WALL, OR FLOOR AS REQUIRED.
5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH
EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ".
6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND
DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK.
DMSI014 VI - ARCHITECRIRAL CARPENTRY AND CASEWORK
06100 - ROUGH CARPENTRY
1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS,
BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED.
06200 - FINISH CARPENTRY
1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND
NOSINGS.
2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED.
06400 - ARCHITECTURAL WOODWORK AND CASEWORK
1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR
CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION.
2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK.
3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH,
AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS /
DETAILS, OR PER BUILDING STANDARD.
4. PLASTIC LAMINATE: HIGH - PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND
FORMICA, UON. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL.
5. INTERIOR CABINET SURFACES & SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON.
6. SHELF EDGING TO BE P -LAM, UON.
7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW.
DIVISION VIN - DOORS AND WINDOWS
08210 - WOOD DOORS
1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS.
2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON.
3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE.
4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW.
5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING
MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT.
08710 - FINISH HARDWARE
1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR
HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO
COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR
LOCATIONS.
2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE.
3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO
(2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH
ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT.
4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW.
5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET,
AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS.
6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES.
7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES.
8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH.
9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT
SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION.
10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER
OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE
FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE.
11. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES.
12. MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES.
13. THE FOLLOWING UL LISTINGS ARE REQUIRED ON THE FOLLOWING HARDWARE:
PANIC HARDWARE - UL #305
FIRE EXIT HARDWARE - UL #106 & UL #305
ELECTROMAGNETIC LOCK HARDWARE - UL # FWAX -S -A -6635
THE CRASH BAR MUST BE AT LEAST 1/2 OF THE DOOR WIDTH AND OPEN FORCE NO MORE THAN 15 LBS.
VERIFY WITH BUILDING STANDARD & MANAGEMENT AND INFORM ARCHITECT IF BUILDING STANDARD DOESN'T
COMPLY.
08810 - GLASS
1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1 /4" TEMPERED SAFETY GLAZING, UON.
2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS.
3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING
SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING
SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY
SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
4. RATED GLASS (CERAMIC) RELITE SHALL BE PREMIUM POLISHED FINISH.
DIVISION IX - FINISHES
09250 GYPSUM DRYWALL AND METAL STUDS
1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS
SHOWN IN THE PLANS.
2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR
RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC.
3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON.
4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE
BUILDING STRUCTURE, UON.
5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE
PARTITION HEADS AND CEILING GRID.
6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL
BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE
MATCHES DOOR FRAMES IN STOCK IF APPLICABLE.
7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF
MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED.
8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE
REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON.
9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF
GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED.
10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE
FINAL FINISHING AS SPECIFIED.
11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE STRUCTURAL DIAGONAL BRACING AS
NECESSARY.
12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS
OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS.
13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH
SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED
WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS.
14. FIRE AND SMOKE SEPARATION ASSEMBLIES SHALL BE MARKED AS REQUIRED IN IBC SECTION 703.6.
09500 - CEILING SUSPENSION SYSTEMS.
1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED
ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS.
2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING
MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE.
3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA
CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS.
4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING
FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS.
5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON.
6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATION AND CODES.
7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER.
8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS
REQUIRED.
9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN,
LEVEL AND MATCH NEW CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT
OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCONTINUITIES IN THE CEILING WITHIN
10 DAYS.
10. ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CEILING CONDITIONS IF NECESSARY.
09530 - ACOUSTICAL TREATMENT
1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF
PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS.
2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND
TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON.
09650 - RESILIENT FLOORING
1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND
MANUFACTURER PER FINISH SCHEDULE.
2. PROVIDE RUBBER - REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR
AT ALL AREAS OF FLOOR MATERIAL TRANSITION.
3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT
OUTSIDE CORNERS OR WITHIN 6" OF CORNERS.
4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MFR'S WRITTEN
INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'.
5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS
SPECIFICATION, UON.
6. UNLESS SPECIFIED ALL RUBBER BASE SHALL BE COVED BASE.
09680 - CARPET
1. PROVIDE AND INSTALL COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS.
2. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED
SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'.
3. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW.
09900 - PAINTING AND STAIN
1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2)
FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE
FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS.
2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS.
A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO
(2) FINISH COATS.
B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH
A COMMERCIAL GRADE CLEAR SATIN VARNISH.
3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL
SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (1) COAT
PRIMER AND TWO (2) FINISH COATS. GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES.
4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL
SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (1) COAT
PRIMER AND TWO (2) FINISH COATS. GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES.
5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL
OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME.
6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES.
7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH
AS THE ROOM, UON.
8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES).
9. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH.
10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH.
11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO
PRODUCE SMOOTH FINISH.
12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING.
MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING.
DIVISION XII - FURNISHINGS
12500 - WINDOW TREATMENT
1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW
CONDITION.
2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING
MANAGEMENT. MATCH EXISTING CONDITIONS UON.
3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI - BLINDS WHERE INDICATED IN DRAWINGS.
4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW.
12900 - SIGNAGE
1. PROVIDE AND INSTALL ALL CODE REQUIRED SIGNAGE.
DIVISION XV - MECHANICAL
15400 - PLUMBING
1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQ
DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER
HEATERS, ETC.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
City of Tukwila
BUILDING DM ' ION
2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT.
3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON.
4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPLICABLE.
5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. VERIFY
LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS.
6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL
CODES.
7. CONTRACTOR SHALL PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION.
8. VERIFY WATER SUPPLY & SEWER DRAIN CAPACITY FOR ENTIRE BUILDING WILL MEET NEW CAPACITY WHEN
NEW RESTROOMS ARE ADDED TO BUILDING.
15500 - FIRE PROTECTION
1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND
ORDINANCES.
2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS
REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH
DISABILITIES ACT.
3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY
APPLICABLE LOCAL CODES AND LAWS.
4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE
EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE,
UON.
5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY
LOCATION WITH FIRE MARSHALL. WHEN REQUIRED BY CODE, PROVIDE 1 WALL MOUNT TYPE IN EACH SERVER
ROOM OR LABORATORY.
6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE:
A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS.
B. PRESSURE REQUIREMENTS.
C. SPRINKLER HEAD SPECIFICATIONS.
D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS
7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES.
8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON.
9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. CONTRACTOR SHALL VERIFY EXTENT OF
QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT.
15800 - HEATING VENTILATING AND AIR CONDITIONING
1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR
COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED.
2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE:
A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS.
3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND
BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.
4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND
THERMOSTATS.
5. RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR
ALTERED SUITES.
16000 - ELECTRICAL AND TELECOMMUNICATIONS
1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE
OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE.
2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM.
PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN.
3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH
MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA
CABLE CONFIGURATION WITH THE TENANT.
4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON.
5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON.
6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND
FAULT INTERRUPTED CIRCUIT.
7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE
ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT,
"EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE
GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING
STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT.
8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS,
COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS.
9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE
INSTALLATION OF TENANT'S NEW FURNITURE.
10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN
FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND
SHALL BE COORDINATED BY THE BUILDING MANAGER.
11. THE CONTRACTOR IS TO COORDINATE WITH THE TENANTS SUPPLIED FURNITURE SYSTEMS TO INCLUDE
BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J- BOX LOCATIONS, CONNECTIONS AND WALL
MOUNTED REQUIREMENTS.
12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED
WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE
NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH.
13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING
SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S
GUIDELINES.
14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION
COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION
BETWEEN EACH DEVICE.
16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED
FOR ACOUSTICAL CONTROL.
17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT
BEFORE INSTALLATION.
18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO
INSTALLATION.
19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN /BUILD
DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE.
20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT
LOCATION WITH FURNITURE VENDOR.
21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR
ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK.
22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES
AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK.
23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS.
24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY
BUILDING MANAGEMENT FOR ALTERED SUITES.
16500 - LIGHTING
1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE
MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND
REGULATIONS.
2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON.
3. WHEN WORKING IN PUBLIC CORRIDOR VERIFY SWITCHING REQUIREMENTS WITH BUILDING MANAGEMENT.
4. VERIFY WITH BUILDING MANAGEMENT SEPARATION OF SUITE SWITCHING WHEN DEMISING CONFIGURATIONS
CHANGE.
5. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN
THE CENTER OF CEILING TILE OR CENTER OF 2X2 PORTION OF 2X4 SECOND LOOK TEGULAR TILE. UON.
6. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND
TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY
BALLASTS.
7. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT
OF WORK.
8. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING - HEIGHT PARTITIONS, AND
ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE.
9. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE:
A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES.
B. LIFE SAFETY EQUIPMENT.
C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES.
D. LIGHT FIXTURE SPECIFICATIONS
RECEIVED
APR 27 2012
PERMIT CENTER
10. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION.
11. CONTRACTOR SHALL RE- CIRCUIT AND RE- SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES
AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY
AND OPEN OFFICE SWITCHES AS NEEDED.
12. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE
REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT.
13. PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY LIGHTING AS DIRECTED
BY EXISTING CONDITIONS AND CODE REQUIREMENTS.
14. EXIT SIGNS SHALL HAVE UL #924.
12 -143
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
eg
burgess design I interiors 0 architecture
1776 Fifth Avenue Suite 500 . Seattle . WA 98101 TEL' 706.587,7120 FAX :706. 587.7122
M reproduction & intellectual property rights reserved c 2012
Professional seal
No. Issue Description
Date
PERMIT SET
04.25.12
Drawn by: MK
Project No: 12.SB13.00
Reviewed by: RM
PROJECT NOTES
Original drawing is 24" x 36 °. Scale entities accordingly if reduced
G.0.1
L1
1, q-1
a�N CYC
BK SWK RT
3311 S. 120TH PL.
BUILDING 2
107,489 S.F.
V —N SPRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
AREA OF WORK
0
TP
EP
SITEPLAN-NOTALEGAL SURVEY f\
0 t
0
0
0 16' 21
8' 16' 24'
1/8" = 1'- 0"
P(UG)
RECEIVED
APR 27 2012
PERMIT CENTER
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design J interiors CO architecture
1326 Fifth Arenne Suite 500 . Seattk . WA 98101 TEL: 206.587 7120 FAX:206. 587 7127
All reproduction & intellectual property rights reserved c 2012
Professional seal
R STERED
' CHITECT
No. Issue Description
Date
PERMIT SET 04.25.12
Drawn by: MK
Project No: 12.S813.O0
Reviewed by: RM
SITE PLAN
Original drawing is 24" x 36 ". Scale entities accordingly if reduced
G.0.2
IT SIR, DOOR
LANDING/
4111816.N ..71141. #005.71
NEW PATH OF TRAVEL.
THE PATH OF
EMERGENCY EGRESS
TRAVEL ILLUMINATION
LEVEL SHALL NOT BE
LESS THAN AN AVERAGE
OF (1) FOOT CANDLE AT
THE WALKING SURFACE
EXISTING COMMON PATH OF EGRESS
TRAVEL DOES NOT EXCEED 100 FEET TO
DECISION NODE. THE PATH OF EMERGENCY
EGRESS TRAVEL ILLUMINATION LEVEL IS
NOT LESS THAN AN AVERAGE OF (1) FOOT
CANDLE AT THE WALKING SURFACE. -
EXISTING PORTION OF EXIT PATH TO BE
RELOCATED.
EXISTING EXIT PATH -10 REMAIN
DATA CENTER
12,390 S.F.
OCC. LOAD — 300 S.F /OCC. = 42 OCC.
BASED ON SUBMITTAL UNDER 1997 UBC IN
2000.
417 S.F.
OCC. LOAD:
100 S.F OCC. =5 OCC.
ITE 120
NEW DOOR, STAIR, AND
CONCRETE LANDING
REVISED UNDER
PERMIT D10 -340.
EXIT
RECEPTION
278 S.F.
OCC. LOAD:
15 S. F /OCC. =19 OCC.
MOVE UNISTRUTS
EXIT l
- CHAINLINK GATE WITH
LOCKSET AND
CONCRETE WALK
TOTAL OCCUPANT LOAD AT THIS EXIT
90 OCCUPANTS
CODE PLAN
CODE INFORMATION
PROJECT ADDRESS: INTERGATE EAST — BUILDING 2
SUITE 125
3311 SOUTH 120TH
TUKWILA, WA 98168
PARCEL NUMBER: 102304 - 9078 -05
LEGAL DESCRIPTION: NE 1 OF THE SE 1 OF THE SE 1 OF THE SE 1 OF SECTION 9 AND
GOVERNMENT LOT 15 AND SW 1 OF THE SW 1 OF SECTION 10, T23n., R4E., W.M. CITY OF
TUKWILA, KING COUNTY WASHINGTON
APPROXIMATE AREA OF CONSTRUCTION: 2,150 SQFT
TOTAL APPROXIMATE SUITE AREA (SUITE 120): 22,069 SQFT
SUITE AREA (SUITE 160): 26,669 SQFT
TOTAL APPROXIMATE BUILDING FLOOR AREA: 107,489 SQFT
OCCUPANCY TYPE: SUITE 120; 'B' (EXISTING) WITH ACCESSORY
USE
SUITE 160; 'F -1' (EXISTING)
USED TO SUPPORT MAIN
NUMBER OF EXITS REQUIRED: 2 REQUIRED; 2 PROVIDED (SUITE 120)
(SUITE 160)
COMMON PATH OF EGRESS TRAVEL: 100' SPRINKLERED NFPA 13
CODE SHEET: SYMBOLS LEGEND
EXIT SIGNS
MEANS OF EGRESS PATH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
APR 27 2012
PERMIT CENTER
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design I interiors 0 architecture
1325 Fifth Avenue Suite 500 . Seattle - WA 98101 TEL 206.587 7120 fAX;206. 587.7122
All reproduction & intellectual property rights reserved c 2012
Professional seal
r 8021
TERED
ITECT
RANDALL ALAN MORGAN
SEIZE OF WASHINGTON
No. Issue Description
Date
PERMIT SET
04.25.12
Drawn by: MK
Project No: 12.SB13.00
Reviewed by: RM
CODE SUMMARY
Original drawing is 24" x 36 ". Scale entities accordingly if reduced
G.0.3
C?
DEMOLITION /CONSTRUCTION PLAN ■■
0
8'
16'
24'
1/8" = 1'- 0"
❑
EXPANDED
❑ DATA ROOM
POWER /DATA Sc FLOOR FINISH PLAN 8
0
8'
16'
24'
1/8" = 1'- 0"
SHADED AREA IS
APPROXIMATE AREA OF
NEW RAISED FLOORING
SYSTEM
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
City of Tukwila
BUILDING DIVISION
LL3
DEMO /CONSTRUCTION SYMBOLS
KEYED DEMO /CONSTRUCTION NOTES
WALL MOUNTED DEVICES
FINISH SPECIFICATIONS
_ EXISTING CONSTRUCTION TO REMAIN
1 DEMO DOOR, FRAME, AND HARDWARE - TO BE STORED OR RELOCATED AND REINSTALLED WHERE
O APPLICABLE. VERIFY WITH BUILDING MANAGEMENT.
2 DEMO RECITE - TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE. VERIFY WITH
O
BUILDING MANAGEMENT.
O DEMO EXISTING CASEWORK AND END WALLS. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISHES.
4O DEMO EXISTING CARPETING. PATCH AND REPAIR SURFACES AS REQUIRED FOR INSTALLATION OF NEW
RAISED FLOORING, OR ANY OTHER NEW FINISH.
5O DEMO EXISTING ACOUSTIC WALL PANELING. PATCH AND REPAIR WALL SURFACE AS REQUIRED FOR NEW
FINISHES.
O VERIFY THAT THERE IS 7' -4" CLEAR AT BRACE FRAME, TO CLEAR DOOR AND FRAME.
7O ALIGN NEW PARTU1ON WITH EDGE OF EXISTING COLUMN.
O8 REMOVE EXISTING EXIT SIGN AS EXIT PATH HAS CHANGED AT THIS LOCATION, PER G.0.3.
SYMBOL
DESCRIPTION
SYMBOL
MANUFACTURER
DESCRIPTION
f f EXISTING CONSTRUCTION TO REMAIN
f� ■f NEW INSULATED INTERIOR PARTITION PER K
EXISTING TO REMAIN
_
B AS E
CONSTRUCTION, DETAIL /A.9.1
F.E.C. NEW OR EXISTING FIRE EXTINGUISHER
D
ACCESS CONTROL SYSTEM VERIFY TYPE WITH TENANT AND SYSTEM REQUIREMENTS
(rif ijlWjr OR Bums Iiewili I1) WITH TENANT AND BUILDING MANAGEMENT.
_
4 "h COVED RUBBER BASE.
COLOR: -
CR
B-1
QuAD�P�X °`�`�
PAINT
GENERAL DEMOLITION NOTES
M
I S C . NOTATION
BENJAMIN MOORE
GWB EGGSHELL FINISH
COLOR: -
1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION.
2. SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE -USE, LION.
3. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE -USE, UON.
4. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOUSHED
PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING
SOURCE, UON.
5. REMOVE ALL FLOOR AND WALL FINISHES EXCEPT FOR EXISTING ROOMS NOTED AS NOT IN CONTRACT OR OTHERWISE
INDICATED IN THE KEY NOTES.
P -1
N
DENOTES A NEW DEVICE
BENJAMIN MOORE
GWB EGGSHELL FINISH
COLOR: -
P-2
GENERAL ELECTRICAL NOTES
GENERAL FINISH NOTES
1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS.
2. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS
NOTED TO REMAIN.
3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P /P /D MAY EXIST BUT NOT BE
REFLECTED ON THE PLANS.
4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH
TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT.
5. UNLESS DIRECTED OTHERWISE, ALL VOICE /DATA CABUNG AND EQUIPMENT ASSOCIATED WITH VOICE /DATA SERVICE
INCLUDING WORK FROM BUILDING /FLOOR D -MARK TO SERVER ROOM SHALL BE FURNISHED AND INSTALLED BY
TENANT.
1. PROVIDE B -1 THROUGHOUT, UON.
2. PROVIDE P -1 THROUGHOUT, UON.
3. PROVIDE CPT -1 THROUGHOUT, UON.
4. REFER TO ELEVATIONS AND DETAIL SHEETS.
5. CENTER TRANSITION BETWEEN MATERIALS UNDER DOOR PER DETAILS.
GENERAL CONSTRUCTION NOTES
1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS.
2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK.
3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED,
GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTMON RATINGS.
4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL /CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS
AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH.
5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR
ATTACHED TO PARTITIONS.
6. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL
SHEET FOR MORE INFORMATION.
7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL
OR MATCH EXISTING SUITE STANDARD.
8. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE- RETARDENT TREATED WOOD WHEN BUILDING IS
CONSTRUCTION TYPE I AND II.
9. REFILL ANY ABANDONED CORE DRILL HOLE OR SIMILAR WITH FIRE PROOFING THAT MATCHES THE FLOOR
RATING. UON.
K EYED P 0 W E R DATA &
/
FINISH NOTES
10 DATA ROOM: COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT.
11 FINISH OF NEW RAISED FLOORING SYSTEM TO MATCH THAT OF EXISTING ADJACENT RAISED FLOORING
SYSTEM.
12 NEW CARDREADER AND PUSH TO EXIT DEVICE. CARD ACCESS TO MEET THE REQUIREMENTS OF IBC
SECTION 1008.1.4.4 EXCLUDING N0.6 �C p��® �/ ��
APR 27 2012
PERMIT CENTER
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design
nteriars Q architecture
1726 Fifth Avenue Suite 500 . Scattle _ WA 98101 TEL. 206.587.7170 FAX.296. 587.7122
All reproduction & intellectual property rights reserved c 2012
Professional seal
No. Issue Description
Date
PERMIT SET 04.25.12
Drawn by: MK
Project No: 12.SB13.00
Reviewed by: RM
DEMOLITION/
CONSTRUCTION/
POWER & DATA/ FINISH
PLANS
Original drawing is 24" x 36 ". Scale entities accordingly if reduced
A.2A.1
n
I\1
1— +— I- DI— +—I —H41+ �I-
J—L1 _L111(S I
I I I;1 1 111 I�
I I I'
—r111-
_1J_LI J_L1 —L_111 Jrt
1 I I I I I 111 I
�T�— (&1 —TT —rT-1
_I_ _IL_ L__L_J._L
III
lL�
_J
A REFLECTED CEILING PLAN -DEMO ■■
0 8' 16' 34'
❑
BREFLEC TED CEILING PLAN -NEW (\\
,- 1,8" = ,.- 0"
0 8' 16' 24'
GN) i
0
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
City of Tukwila
BUILDING DIVISION
CEILING
LEGEND
LIGHTING
GENERAL RCP SHEET NOTES
KEYED RCP NOTES
LIGHTING SUMMARY
SYMBOL
DESCRIPTION /SPEC
0
EXISTING RECESSED CAN LIGHT
TO REMAIN.
EXISTING 1' X 4' FLUORESCENT
FIXTURE TO BE REMOVED.
EXISTING RECESSED CAN LIGHT
TO BE REMOVED.
EXISTING 1' X 8' FLUORESCENT
FIXTURE TO BE REMOVED.
9N /R
NEW OR RELOCATED RECESSED
CAN LIGHT.
NEW BUILDING STANDARD
1' X 4' FLUORESCENT FIXTURE
Nom- E = EXIST.
N = NEW
NEW B/S EMERGENCY FIXTURE
PER IBC 1006.
NEW BUILDING STANDARD
1' X 8' FLUORESCENT FIXTURE.
EXISTING EXIT SIGN TO REMAIN.
COORDINATE WITH CODE
OFFICIAL.
NEW RACKROOM SUSPENDED
CEIUNG GRID SYSTEM
EXISTING EXIT SIGN TO BE
REMOVED
eN /R
N = NEW
NEW OR RELOCATED EXIT SIGN.
COORDINATE FINAL LOCATION
WITH CODE OFFICIAL.
CEILING LEGEND
CONTROLS
SYMBOL
DESCRIPTION
NEW SWITCH LOCATION.
1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS.
2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD
ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEIUNG PLAN DESIGN.
3. UGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR
SPECIFIC LOCATION AND SWITCHING DIAGRAMS.
4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND
COVERED WITH A SINGLE COVERPLATE.
5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN.
6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT.
7. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE
RELOCATED.
8. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES
DESIGNATED AS NEW.
9. DRAWING SHOWS ONE METHOD OF PROVIDING EGRESS ILLUMINATION FOR IBC 1006. CONTRACTOR IS RESPONSIBLE
FOR DESIGN OF THIS SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT'S EXISTING
SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE.
10. THE CONTRACTOR UNDER THE DESIGN BUILD CONTRACT SHALL PROVIDE A MINIMUM OF 1 FOOT- CANDLE PER SQUARE
FOOT, AS MEASURED FROM 18" FROM ABOVE THE FINISHED FLOOR, FOR EMERGENCY EGRESS LIGHTING CONTINUOUSLY
ALONG THE ENTIRE LENGTH OF THE PATH OF TRAVEL
O1 DEMO EXISTING GWB CEILING, SOFFITS, LIGHTING, CURTAIN RAILS AND CEILING MOUNTED EQUIPMENT.
REMOVE ALL ASSOCIATED STRUCTURE AND SUPPORTS FOR DEMO'D ITEMS. PATCH AND REPAIR WALL AS
REQUIRED FOR NEW FINISHES. VERIFY ANY STORAGE AND REUSE OF LIGHTING FIXTURES AND CEILING
EQUIPMENT WITH TENANT AND BUILDING MANAGEMENT.
O DEMO EXISTING ACT CEILING SYSTEM AND LIGHTING FIXTURES. VERIFY ANY STORAGE AND REUSE OF
LIGHTING FIXTURES WITH BUILDING MANAGEMENT.
PAINT STRUCTURE ABOVE TO MATCH ADJACENT "BLUE" PAINTED STRUCTURE. CLEAN -UP ALL WIRING AND
CABLING TO PROVIDE A "WELL ORGANIZED" LOOK.
ATTACH WALL EXIT SIGN TO WALL ABOVE DOOR.
PRICE AS ALTERNATE:
O NEW EXPANDED DATA CENTER SUSPENDED GRID SYSTEM, TO MATCH EXISTING ADJACENT SUSPENDED CEILING
SYSTEM. VERIFY EXTENT OF SUSPENDED GRID SYSTEM WITH TENANT. REFER TO DETAIL A /A.9.1
2009 Washington State Nonresidential Energy Code Compliance Form
Lighting Summary LTG —SUM
2009
Project Info
Project Address: CORELINK
Date 04/22/12
3311 SOUTH 120TH PLACE —BLDG 2
For Building
Department Use
TUKWILLA, WA 98168
Applicant Nome: BURGESS DESIGN INC.
Applicant Address: 1326 FIFTH AVENUE, 1500, SEATTLE, WA 98101
Applicant Phone: 206 587 7120
Project Description
❑ New Building ❑ Addtien Di Abram
Compliance Option
❑ PraspiPpfe ® lighting Pacer Allowance ❑ Systems Analysis
(See Qualification t:lacldist ( over). Indicate Preemptive & LPA spaces clearly on plans.)
❑ No changes are being mode to the fighting
(2) Lae than 607E of the fixtures are new and installed fighting wattage is not being increased
LIGHTS TO BE REMOVED:
(7) 1x8 AT 108 WATTS EACH: 756 WATTS
(21) RECESSED DOWN LIGHTS AT 32 WATTS EACH: 672 WATTS
TOTAL WATTS REMOVED: 1,428 WATTS
LIGHTS TO BE ADDED:
(9) 1x8 AT 108 WATTS EACH:
(4) 1X4 AT 56 WATTS EACH:
972 WATTS
224 WATTS
TOTAL WATTS ADDED: 1,196 WATTS
UGHTING WATTAGE DIFFERNCE:
( -)232 WATTS
17 1 H
RECEIVED
APR 27 2012
PERMIT CENTER
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design I interiors 0 architecture
1225 Fifth Avenue Suitt 500. Scattk _ WA 98101 TEL: 206.587.7120 FAx206, 5877127
All reproduction & intellectual property rights reserved c 2012
Professional seal
No. Issue Description
Date
PERMIT SET
04.25.12
Drawn by: MK Reviewed by: RM
Project No: 12.SB13.00
REFLECTED CEILING
PLANS
Original drawing is 24" x 36 ". Scale entities accordingly if reduced
A.2B.1
EXISTING STRUCTURE]
NEW METAL SUPPORT
CHANNEL
THREADED SUPPORT
ROD
NEW RACK SYSTEM
TO MATCH EXISTING
ADJACENT
'IV EXIST.
MATCH EXISTING RACK SPACING
(BOTH DIRECTIONS)
PROVIDE CROSS
BRACING AS REQUIRED
NEW METAL SUPPORT
CHANNEL
SUSPENDED RACK GRID DETAIL (ALTERNATE)
NTS
r
BOTTOM OF STRUCTURE
LONG LEG TOP TRACK
VERIFY SIZE AND LOCATION
OF DUCTING
PROVIDE 20 GA. TRACK
LOCATIONS OF CONDUIT
BUNDLE OR PIPING WERE
STUDS ARE REQUIRED TO
BE FORESHORTENED
2 1/2' X 20 GA METAL
(33 MILS) STUDS 0 24"
OC, TO 11'-7" MAX.
HEIGHT.
1 LAYER 5/8" TYPE "X'
GYP. BD. EA. SIDE OF
METAL STUDS ATTACHED
W/ 16 SCREWS 0 12"
O.C. MAX.
POWDER DRIVEN
FASTENER 0 24" OC
MET. RUNNER TRACK
SEALANT
CONCRETE SLAB
nNON-RATED FLOOR TO CEILING PARTITION
�KJ
12"
3" = 1,_U"
CV
m
DEVICES SHOWN STACKED IN
PLAN ARE TO ALIGN VERT.
AS SHOWN BELOW
AT LOCATION AS DIMENSIONED ON
PLAN; OR NEXT TO DOOR /
OPENING AS DIMENSIONED BELOW
FIRE ALARM STROBE
FRAME WHERE OCCURS
ROOM SIGNAGE, ETC.
THERMOSTAT
LIGHT & PROJECTION SCREEN
SWITCHES, WALL MOUNTED
OCCUPANCY SENSOR
CARD READER WHERE
OCCURS
HARDWARE LATCH
TELEPHONE OUTLET
FINISHED FLOOR
ELECTRICAL OUTLET
1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN,
UNLESS SPECIFICALLY
2. DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. CENTER FIRE ALARM STROBES DIRECTLY ABOVE
FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR.
3. DETAIL IS SCHEMATIC IN NATURE AND ADA COMPLIANCE MAY BE ACHIEVED WITHIN A RANGE. VERIFY WITH ARCHITECT IF
QUESTIONS.
4. IN AREAS WHERE ACCESS FLOOR HAS BEEN REMOVED; VERIFY WITH BUILDING MANAGEMENT AND TENANT WHETHER DEVICES
SHOULD BE ALTERED TO STANDARD HEIGHTS. LIGHT SWITCHS MUST BE LOWERED TO ADA COMPLIANT HEIGHTS.
GENERAL DEVICE ALIGNMENT
NTS
DOOR & HARDWARE GENERAL NOTES
1.
SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION.
2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME
0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES.
3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N.
4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS.
5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS.
DOOR SCHEDULE
ac
W
C
�oo
Q
DOOR
NOMINAL WIDTH
NOMINAL HEIGHT
HARDWARE GROUP
5
C.7
100
3' -0"
MATCH
EXIST
A
1
WD
N/A
HARDWARE GROUP
HARDWARE GROUP
HARDWARE
REMARKS
GROUP 1
SINGLE, LOCKSET WITH ACCESS
CONTROL
NON —RATED
1 STOREROOM FUNCTION LOCKSET
3 EA OF HINGES
1 DOOR CLOSER
1 FLOOR — MOUNTED DOOR STOPS
1 ELECTRIC STRIKE
ACCESS CONTROL SYSTEM (BY OTHERS)
SYSTEM SHALL COMPLY WITH
INTERNATIONAL BUILDING CODE SECTION
1008.1.4.4 AND ANY LOCAL
REQUIREMENTS.
DOOR TYPES
C.
WIDTH
A
WOOD FRAME
FINISH TO MATCH
SUITE STANDARD
FLUSH S.C.
WOOD DOOR
FINISH TO MATCH
SUITE STANDARD
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
APR 27 2012
PERMIT CENTER
Tenant:
CORELINK
INTERGATE EAST _BUILDING 2
3311 SOUTH 120TH PLACE
TUKWILLA, WA 98168
burgess design
interiors le architecture
1326 fifth Avenue Suitc 500 . Scattk - WA 88101 1EL. 206.587.7120 FAX 206. 587 7122
All reproduction & intellectual property rights reserved c 2012
Professional seal
8021
REeST,ERED
No. Issue Description
Date
PERMIT SET
04.25.12
Drawn by: MK
Project No: 12.SB13.00
Reviewed by: RM
DOOR SCHEDULE /
DETAILS
Original drawing is 24" x 36 ". Scale entities accordingly if reduced
A.9.1