HomeMy WebLinkAboutPermit D12-157 - MOUNTAIN VIEW APARTMENTS - REROOFMOUNTAIN VIEW
APARTMENTS
14200 37 AV S
EXPIRED 11-21-12
D12-157
City ofkukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 1610000225
Address: 14200 37 AV S TUKW
Suite No:
Project Name: MOUNTAIN VIEW APARTMENTS
Permit Number: D12 -157
Issue Date: 05/16/2012
Permit Expires On: 11/12/2012
Owner:
Name: MOUNTAIN VIEW FAMILY ASSOC
Address: QUANTUM MANAGEMENT SVCS INC , PO BOX 2170 98036
Contact Person:
Name: DAMON SHELTON
Address: 1813 130 AV NE , BELLEVUE WA 98005
Contractor:
Name: ELEMENT SMART ROOFING
Address: 1813 130 AV NE, SUITE 110 , BELLEVUE WA 98005
Contractor License No: ELEMESR902BH
Lender:
Name:
Address:
Phone: 425 - 968 -3000
Phone: 425 - 881 -2977
Expiration Date: 04/05/2013
DESCRIPTION OF WORK:
REROOF
Value of Construction: $16,000.00 Fees Collected: $653.61
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0021
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -157 Printed: 05 -16 -2012
• •
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
co,,Q1
Date: �� b
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of wo ut rized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name: ci■/ Q
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
doc: IBC -7/10
D12 -157 Printed: 05 -16 -2012
7: All construction noise to be in complianciph Chapter 8.22 of the City of Tukwila Municieode. A copy can be
obtained at City Hall in the office of the City Clerk.
8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate
shall be provided to the building inspector.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -157 Printed: 05 -16 -2012
CITY OF TUKWILA .
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No. l )-- 15 7
Project No.
Date Application Accepted: S -"q
Date Application Expires: `\ -- 2
(For office use. only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Address:
King Co Assessor's Tax No.: (P 0 t) L j
\92o0 1 *ye. 5-
Suite Number:
Tenant Name: W1(2 ✓A/ -t-)` (4w "I.Qvv\) P41-5 S B C . New Tenant:
PROPERTY OWNER
Name: .� (1 t'✓ S tvz L k„ ti
Address: t . ` j o n v& 0,1E:-
City:`\/�Q State:
Zip: (�� oily
f
Name: VOVrA.M^, \/.Qv
J�Vvm)'x A1)0f .
Address: ; 1 Lp V
J i
A vt f.
City: `.c..-1/411C,A1 ‘,..1 14
State: yv4
Zip: )13 1 ie
CONTACT PERSON — person receiving all project
communication
Name: .� (1 t'✓ S tvz L k„ ti
Address: t . ` j o n v& 0,1E:-
City:`\/�Q State:
Zip: (�� oily
f
Phone: J-, n " ,, G Fax:
Email: d Av� 'iv . 'e-SR 0 °) vi.--j . Cam•
GENERAL CONTRACTOR INFORMATION;
Company Name: e ( tc--- 1 4,...4_2A- (2_,_ /C.
Address: I t 3 l O p..,e A/ (�/(
3
City: „ ( 0 , t State: �A ZIp: f N o
'g2Va l-'
Phone: 9.t_Q_ 3 /U6 Fax: 42. t Ij1 •3 c,, T.
hell T„
Contr Reg No.:t` n o p9nl�xp Date: ir Za
Y
Tukwila Business License No.: -
H: \Applications \Forms- Applications On Line \21111 Applications \Permit Application Revised - 8 -9 -I I.docx
Revised: August 2011
bh
1.
Floor:
❑ Yes [ No
ARCHITECT. OF RECORD
Name:
V
Company Name:
Architect Name:
Address:
City:
State:
Zip:
Phone: .
Fax:
Email:
N
ENGINEER OF RECORD
Name:
Address:
Company Name:
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000, or
greater per RCW 19.27.095)
Name:
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ a 0 0
Describe the scope of work (please provide detailed information):
Will there be new rack storage? ❑ Yes
Existing Building Valuation: $ ti 4 r9 000
No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing 1 Interior Remodel
Addition to
Existing
Structure
Type of
Construction per
IBC
Type of
Occupancy per
IBC
Ist`Floor
2' Floor
3rd Floor
Floors thru'
Basement
Accessory Structure*
Attached Garage
Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\ Applications \Forms- Applications On Line \2011 Applications \Permit Application Revised - 8-9-1 I.docx
Revised: August 2011
bh
Page 2 of 4
PERMIT; APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAV.. 1 ND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE L E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHO
Signature:
Print Name:
ow :d A r0 - 5,
Mailing Address: S ' 7 t) J A- viz. /1/&*-
ll &
H:\ Applications \Forms- Applications On Line \2111 I Applications \Permit Application Revised - 0-9 -1 I.docx
Revised: August 21111
bh
Date: 519/ a tz9 �-
Day Telephone: 4/2._ S- 9 4' g
q dk ✓4 Q fNq- 9 Ooo.S'-
City State Zip
•
Page 4 of 4
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.aov
RECEIPT
Parcel No.: 1610000225 Permit Number: D12-157
Address: 14200 37 AV S TUKW Status: APPROVED
Suite No: Applied Date: 05/09/2012
Applicant: MOUNTAIN VIEW APARTMENTS Issue Date:
Receipt No.: R12 -01599
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $397.90
Payment Date: 05/16/2012 11:08 AM
Balance: $0.00
DAVID JONES
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
RD Pmts Re -Dist OP
Authorization No. 603768
ACCOUNT ITEM LIST:
Description
397.90
.00
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - NONRES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
000.345.830
640.237.114
Total: $397.90
393.40
- 255.71
255.71
4.50
doc: Receiot -06 Printed: 05 -16 -2012
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 1610000225 Permit Number: D12 -157
Address: 14200 37 AV S TUKW Status: PENDING
Suite No: Applied Date: 05/09/2012
Applicant: MOUNTAIN VIEW APARTMENTS Issue Date:
Receipt No.: R12 -01539
Payment Amount: $255.71
Initials: WER Payment Date: 05/09/2012 04:08 PM
User ID: 1655 Balance: $397.90
Payee: DAVID JONES
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 936540
ACCOUNT ITEM LIST:
Description
255.71
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 255.71
Total: $255.71
doc: Receiot -06 Printed: 05 -09 -2012
,INSPECTION RECORD
Retain a copy with permit
INSPECTION; NO. '; PERMIT NO.
CITY OF` TUKWILA BUILDING DIVISION
6300 Southcenter-.Blvd., #100, Tukwila. WA 98188 (206) 431-367d
Permit Inspection Request Line (206) 431 -2451
P o ect '7
t Q ._
Ca Jt!, I-
Type,o_f Ins ection: l
/ --t0c' � C -! 'it �s
Mo it.titA_ /L` V.
Address:.
(4706
NV.-
n1 /WE
Date Called:
r
Special Instructions: -
(`. 2 �a
Date Wanted::, .--
a.m.
3 —�.j `(2. -prfr
Requester:
Phone N
2. 3 ,. q24 -3 .167
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
I Ak 0.
6-7); .1.-4rf- t
r° 11
D a t e : r
v �
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300:Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION: N0.
INSPECTION RECORD
Retain a copy with permit
b/2-/57
PERMIT NO.
CITY - OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
g'?6 /ivi2/�1
/ t r ,
Type of Inspection:
ire ' Pi?--- • ? x,.26
Address:
/-1 00 -..2'7
4i/-
Date Called:
Special Instructions:
Date Wanted:.
.- 7 ,9-, ,2_
Ana.
p.m.
Requester:
Phone No:
d33 - Sz / -3YG 5
pproved per applicable codes. D Corrections required prior to approval.
COMMENTS:'
r
RVNjSPECTION FEE REQUIR
paid at 6300 Southcenter Blvd.,
Date;
/8 -1',
Prior t.6 next inspection. fee must be
uite 160. Call to schedule reinspection.
5/9/2012
City of Tukwilla
Building Permit
Mountain View Properties
Re Roof /ReCover
FILE COPY
PemtNo.,
Provide written narrative describing existing roof, and roofing material to be installed
Existing Roof
Torchdown Roofing Approx 40 Squares
Roofing Material To be Installed
Durolast — 60 ML Mechanically Attached PVC
1/4" EPS Tapered Insulation System
WORK ITEMS TO BE PERFORMED
Tear Off of roofing and installation of new roofing on Section 1 of the Mountain View
Apartments. Section 1 is defined as the approximate 4,000 square foot roofing section
above Unit #302. See attached photo depiction.
Contractor shall remove and dispose of all roofing layers, flashings, copings, etc. to fully
expose plywood diaphragm.
Contractor shall replace any damaged, rotted, or otherwise unusable plywood roof
sheathing panels with CDX plywood matching existing thickness. Nailing to match
existing nailing pattern.
Roofing:
Roof shall be mechanically attached, heat welded PVC membrane roofing system,
designed for the building conditions and configurations, with a minimum warranty as
specified herein.
Provide base slip sheet supplied and installed per manufacturer's recommendation.
Provide roofing transitions (wall, coping, terminations, scupper, penetrations) per roofi
manufacturer's details and as required to meet specified warranties.
Use fasteners per manufacturer's recommendations. Provide new grommet screws in
exposed metal locations - color match metal. Do not install fasteners in the top of metal
parapet caps.
Do not install roofing in temperatures below 40 degrees F.
Roofing shall meet or exceed a wind rating of 80 mph.
REVIEWED FOR
BODE COMPLIANCE
APPROVED
MAY 11 2012
tvg
City of Tukwila
BUILDING DIVISION
Drainage, Drains, Parapets:
Contractor shall design a drainage system that incorporates the following requirements:
Minimum '/4" per foot slope to the existing drain utilizing an engineered EPS
tapered insulation system.
A designed overflow system that does not allow ponding on the roof greater than
s 7
RECEIVED
MAY 09 2012
PERMIT CENTER
0)
E
O m
z >,
• O)
O rn
0
tY 0
�
QZQ
co
2 rn
w c
• iT)
INN
(j
moo
-N O
N
m
o .-
�.0 c
CD M
y
a�
a)
0)
a
1. PRODUCT NAME
Duro -Last® Specially Formulated
Roofing Membrane (MSDS # 5001)
2. MANUFACTURER
Duro -Last, Inc.
525 Morley Drive
Saginaw, MI 48601
Phone: (989) 753 -6486
(800) 248 -0280
Fax: (800) 432 -9331
Branch Offices
Grants Pass, OR (800) 356 -6646
Jackson, MS (800) 434 -3876
Sigourney, IA (888) 500 -3574
3. PRODUCT DESCRIPTION
Basic Use: The Duro -Last Single -Ply
Roofing System is a prefabricated
waterproofing system used in the
following applications:
• Re -cover over existing systems
• New construction
• Both combustible and
noncombustible decks
Limitations: Duro -Last membrane
must not be installed over assemblies
with saturated under -lying insulation or
directly over existing incompatible roofs
without proper separation.
Composition and Materials: Duro-
Last membrane is a proprietary
thermoplastic formulation consisting of
resins, plasticizers, stabilizers,
fungicides, flame - retardants, and U.V.
absorbers, which is laminated to a weft-
inserted polyester fabric. It is available
in white, tan and gray.
Sizes: For ease of handling and
reduced field seams and faster
installation time, Duro -Last, Inc. factory
welds material in large sheets up to
1,500 ft2 (134 m2) as specified by
architects, contractors, or installers.
The system weighs approximately
0.39 Ib. per ft2 (1.57 kg per m2).
Accessory Components: Duro -Last,
Inc. produces a complete line of
standard and custom - fabricated
accessories. These accessories are
made from the same material as the
deck membrane and are made in a
Duro -Last factory, not on the roof.
Standard Accessories: Round pipe
flashings from 1 inch (2.5 cm) to 15
inch (38 cm) in diameter, inside and
outside corners, two -way roof vents,
roof drain liners, gravel /water stop with
factory welded Duro -Last skirts,
termination bar, and fascia with cover
and joint clips.
Custom- Made Accessories: Round
pipe flashings greater than 15 inch (38
cm), parapet wall flashings, scuppers
and curbs for all types of roof
penetrations. (For example: HVAC
units, skylights, chimneys, etc.) If there
is a need for a custom flashing that has
not been mentioned, provide a drawing
and Duro -Last will manufacture it.
Applicable Standards:
Underwriters Laboratories, Inc., Class
A, B, and C (R- 10128); FM Approvals
from Class 1-60 up to 1-495; Miami -
Dade County, FL; City of Los Angeles,
CA; City of Denver, CO; HUD Material
Release 1223; City of New York, NY
421 -90 -M and 422 -90 -M; IBC: ESR-
1660; Canada: Underwriters
Laboratories of Canada Class A, B and
C (R- 10128); Canadian Construction
Materials Centre CCMC 13299 -L.
4. TECHNICAL DATA
Refer to page 2.
5. INSTALLATION
Duro -Last, Inc. provides detailed
application instructions and training for
roofing contractors and consulting
services to architects, engineers, and
specifiers. The following are general
instructions for installing the Duro -Last
Roofing System.
Deck Surface Preparation: The
substrate on which Duro -Last
membrane is to be applied must be
clean, smooth, free of sharp edges,
loose debris, and standing water.
Gravel should be leveled. All surface
preparations must be done in strict
accordance with the Duro -Last
application specifications.
Insulation: Insulation must be laid on
the deck and cut neatly around all
penetrations. It must then be attached
with approved fasteners according to
the Duro -Last specifications. Do not lay
more insulation than can be covered in
the same day. Stagger the insulation
boards 50% from row to row. No gaps
to exceed 1/4 inch.
Placement: Using the roof layout
diagram, select the proper marked and
rolled premanufactured sheet of Duro-
Last membrane. Orient the membrane
so the fastening tabs are perpendicular
to the ribs or corrugations of steel deck,
or to the width of prestressed concrete
"T" slabs. Secure the membrane to the
roof deck through the fastening tab with
approved fasteners and plates, in
accordance with Duro -Last
specifications. Unfold the sheet,
thus covering the fastening tab.
Continue unfolding until the next
fastening tab appears. Fasten this tab
to the deck and repeat the above
process until the complete sheet is
installed.
Penetrations: During the
aforementioned procedure, make
cutouts in the membrane
forprotrusions. Fasten around cutouts
with Duro -Last approved fasteners. The
skirt of the factory- fabricated
accessories when welded to the deck
membrane will cover these cutouts.
SPEC6D
This Spec -Data sheet conforms to D
the editorial style prescribed by
The Construction Specifications
Institute. The manufacturer is
responsible for technical accuracy.
Breather Vents: One Duro -Last two -
way breather vent must be installed for
each 1,000 ft2 (90 m2).
Parapet Walls: Duro -Last custom
fabricated parapet wall flashings are
designed for each individual
application. Secure through the
fastening tab at the bottom of the wall
using approved fasteners and plates.
The factory- welded skirt will cover the
fasteners when it is heat welded to the
deck sheet.
6. AVAILABILITY AND COST
The Duro -Last Roofing System is
available throughout the United States
and Canada through the Duro -Last
dealer /contractor network and
independent sales representatives. For
pricing, contact Duro -Last, Inc. for the
independent sales representative in
your area.
7. COMMERCIAL WARRANTIES
Upon the successful completion of a
final inspection by a Duro -Last
Technical Representative, Duro -Last,
Inc. will furnish to the Duro -Last
contractor either a 15 -year or 20 -year
warranty.
The 15 Year NDL Warranty covers
material and labor for repair or
replacement for the full 15 years.
The 20 Year Limited Warranty
covers both material and labor for
repair or replacement for the first 10
years. The second 10 years is
prorated and covers material only.
8. MAINTENANCE
Keep the finished roof free of debris.
Do not use roof area for storage. No
other maintenance is required.
9. TECHNICAL SERVICES
Duro -Last, Inc. provides technical
information and roof membrane layout
services to architects, engineers, and
licensed contractors for specifying and
detailed installation of the Duro -Last
Roofing System for various field
applications. Technical brochures,
manuals, and specifications are
available upon request.
Technical field service is also available
through Duro -Last Technical
Representatives.
10. FILING SYSTEM
• Sweets General Building File
07500 /DUR — Buyline 2998
07500
PHYSICAL PROPERTIES
Tests outlined by ASTM D-4434
Test Description
Test Method
Metric Results
U.S. Standard Results
Thickness - Nominal
ASTM D 751
1.5 mm
60 mils - Type 111
Breaking Strength
ASTM D 751 - Grab Method
1,734 x 1,948 N
390 x 438 Ibf
Elongation at Break
ASTM D 751 - Grab Method
31 x 31%
Heat Aging
ASTM 3045, 56 days @ 176° F
90% of Control -no cracking, chipping or crazing
Factory Seam Strength
ASTM D 751 - Grab Method
1,917 N
431 Ibf
Tearing Strength
ASTM D 751 - Procedure B
587 x 725 N
132 x 163 Ibf
Low Temperature Bend
ASTM D 2136
-40° C
-40° F
Accelerated Weathering
ASTM G 154 (Formerly G53)
No cracking, checking, crazing or erosion at 5,000
hours of exposure
Linear Dimensional Change
ASTM D1204 - 6 hrs @ 176° F
-0.45 x - 0,20 %
Water Absorption
ASTM D 570 -166 hrs @ 158° F
2.6 %
Static Puncture
ASTM D 5602
250 N
56 Ibf
Dynamic Puncture
ASTM D 5635
20 J
14.7 ft -Ibf
Additional Tests
Test Description
Test Method
Metric Results
I U.S. Standard Results
Fungi Resistance
ASTM G -21
No sustained growth or discoloration
Solar Reflectance
ASTM C1549
88% - Initial / 68% - 3 year aged
Thermal Emittance
ASTM C1371 -98
87% - Initial / 84% - 3 year aged
Thermal Emissivity
ASTM E408
95%
Solar Reflectance Index (SRI)
ASTM E1980
110 - Initial / 81 - 3 year aged
EMMAQUA Exposure
ASTM G90, Desert Sun
338,904 MJ /m2
> 8.1 million Langley
Moisture Vapor Transmission
ASTM E -96, Proc. B, Method A
< 0.07 g /hr /m2
< 0.22 U.S. Perms
Membrane Weight
ASTM D 751
1.45 kg per m2
0.36 lb per ft2
Underwriters Laboratories (US)
UL -790
Class A, B & C approved
FM Approvals
ASTM E-108; FM 4450 &
FM 4470
Class 1 -60, 1 -75, 1 -90, 1 -105, 1 -120, 1 -135, 1 -150,
1 -165, 1 -195, 1 -210, 1 -240, 1 -270, 1 -345, 1-435,
1-495
Underwriters Laboratories (Canada)
CAN /ULC -S107
Class A, B & C approved
Underwriters Laboratories (Canada)
CAN/ULC-S101
R210, R212, R214, R220. R221, R222, R223, R600,
R700, R701, R703, R801, R802, R803, R805, R806
Notes:
• *Results for membrane tests are shown for both Machine and Cross Machine directions. The machine
direction results are listed first.
• The membrane film thickness above the reinforcement fabric is 28 mil ( + / -) 0.5 mil.
07500
1100051,
1E4RLr%SL'E
COMPANY
ilnsu0Foa Ali® 0
Description
InsulFoam I is a versatile insulation consisting of a superior
closed -cell, lightweight and resilient expanded polystyrene
(EPS). InsulFoam I meets or exceeds the requirements of
ASTM C578, Type I, Standard Specification for Rigid, Cellular
Polystyrene Thermal Insulation. InsulFoam I has a nominal
density of 1.0 lb/ft3. In addition, InsulFoam I offers a long-
term, stable R -Value and has excellent dimensional stability,
compressive strength and water resistant properties.
Uses
InsulFoam I is a quality EPS product and is used in numerous
building construction applications.
Roofing: InsulFoam I is well- suited for single ply roof appli-
cations that employ mechanically fastened or ballasted TPO,
PVC, EPDM and CSPE, as well as low- sloped built -up, modi-
fied bitumen and fully adhered single ply roofs that incorpo-
rate cover boards or slip sheets. Please consult local building
codes and membrane manufacturers for system require-
ments.
Other Construction Applications: InsulFoam I is used in
assorted building applications, including pre- stressed and
pre -cast structural concrete panels, metal roof flute -fill, siding
backer board, building sheathing, roads and bridge fill, below -
slab and perimeter insulation, and numerous other geofoam
applications.
Advantages
Environmentally Friendly. It contains no formaldehyde or
ozone - depleting HCFCs, contains recycled material, and
is 100% recyclable if ever removed or replaced.
Stable R- Value. Designers are well served knowing the
product's thermal properties will remain stable over its
entire service life. There is no thermal drift, so the product
is eligible for an Insulfoam 20 -year thermal performance
warranty.
Proven Performance. The same fundamental EPS chem-
v istry has been in use since the mid- 1950s, so the actual
performance of the product is well known.
Water Resistant. InsulFoam I does not readily absorb
v moisture from the environment.
Code Approvals. InsulFoam I is recognized by the Inter -
v national Code Council Evaluation Service (ICC -ES), and
has numerous Underwriters Laboratory and Factory
Mutual Approvals. Please contact your local Insulfoam
representative for details.
Sizes
InsulFoam I is typically available in 4' x 4' and 4' x 8' sizes with
thickness from 1/4" to 40 ", and is readily available in custom
lengths and widths with little to no impact on lead time. It is
also available in tapered panels.
Typical Tested Physical Properties*
Property ? Method
Density (nom. pcf)
ASTM C303
1.00
C: Value (Conductance) - per inch
BTUI(hrafftze °F)
28 °F
@ 40 °F
T5 °F
ASTM C518
or
ASTM C177
0.230
0.240
0.260
R -Value (Resistance) - per inch
(ihr- ft2^°F)/BTU
026 °F
@40 °F
75 °F.
ASTM C518
or
ASTM C177
4.35
4.17
3.85
Compressive Strength
(ps1,1O% deformation)
ASTM D1621
10 -14
Flexural Strength.(min. psi)
ASTM C203
25
Dimensional Stability •
(maximum %)
ASTM D2126
2.0
Water Vapor Permeance
(max. perm, 1 inch)
ASTM E96
5.0
Water Absorption (max. % vol.)
ASTM C272
4.0
Capillarity
-
none
Flame Spread
ASTM E84
< 20
Smoke Developed '
ASTM E84
150 -300
Properties aro based on data provided by resin manufacturers, independent test
agencies and Insulfoam.
Insulfoam • 19727 57th Avenue East • Spanaway WA 98387 • Toll Free: (800) 248 -5995 • www.insulfoarn.corn
3100 -03/12
SMART ROOFING
FILE COPY
ARC
T
CT
Date: May 9th 2012
Project Name: Mounta n View Apartments
..RAL PLA\
Roof Structure
Fasteners
Spacing Pattern
Notes
Install 1/2" CDX Sheathing where
Needed
Approximately 10 Sheets
1 3/4" 16gauge Staples
Install Vapor Barrier /Separator Sheet
DuroWeave (3.5 mil Thickness)
Duro -Last 60 mil PVC Single Ply
Membrane (4,000 sq ft.)
PVC Clad Raised 8" RVO Vents
Fascia Metal (26 gauge Coping Metal)
2" #14 HD Screws Spade Point with
Barbed cleat Plates
2" and 3" #14 HD Screws Spade
Point (P -3) With Poly Plates
PVC clad, #14 HD Screws.
1 1/2" Woodcrest Grommet Screws
(Brown)
4" OC at Edge, 8" In Field
Tear Off areas where new
plywood needed. Replace
with 1/2" Plywood.
As Needed
Every 12" Feld
9" Parapet up to 18" high
before another row of
fasteners needed
NA
Attached to Outside Edge
ONLY, every 24"
Separate plywood sheathing
from PVC Membrane
PVC Membrane is
mechanically attached using
screws in this plan.
For maintaining and adding
ventilation
Each 10' Piece will be
caulked at seams and
screwed to outside edge
only, not on top or inside
bl2w 157
1813 130th Ave Ne #110 Bellevue, WA 98005 r 425.881.2977 F 425. 881.3014 www.elementsmartmnfina.r•.nm
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 11 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 09 2012
PERMIT CENTER
• ..,..5.kingcounty.gov, . er.hcfn ?el lapsete kc.pc5r ert:.
asa WebAlbums Hotmail ToDoList , Bing Maps M WAIL M Contacts ; Lansing Invoicing Bank of America 1 Ho... Wells Fargo - YRC 2011 el Welcometo My EDGE ... 1GngCty PropSearch L.; Stonewaylmoicin
Cing County
iMAP - Property information
17)
41111111111111111
crl
Parcel Humber!
Address
Assessors Data Report
Districts & Development Report
1010000225
14200 37TH AVE S
Get Assessor Report
'Get Districts Renort
10 -01 -2012
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
DAMON SHELTON
1813 130 AV NE
BELLEVUE WA 98005
RE: Permit No. D12 -157
MOUNTAIN VIEW APARTMENTS
14200 37 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 11/21/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the_Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 11/21/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fifer Marshall
it Technician
File: Permit File No. DI2 -157
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665
•
PLAN
(XV ,,Y
V11' /ROUTING SLIP
ACTIVITY NUMBER: 012 -157 DATE: 05 -09 -12
PROJECT NAME: MOUNTAIN VIEW APARTMENTS
SITE ADDRESS: 14200 37 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
D PARTMENTS:
VG till-
Buil ing- Division
Public Works n
p to
ire Prevention
Structural
Planning Division
❑ Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete n
DUE DATE: 05-10-12
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
nNo further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
DUE DATE: 06 -07 -12
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Peter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name ELEMENT SMART ROOFING UBI No. 601191376
Phone 4258812977 Status Active
Address 1813 130Th Avenue Ne Ste #110 License No. ELEMESR902BH
Suite /Apt. License Type Construction Contractor
City Bellevue Effective Date 1/8/2010
State WA Expiration Date 4/5/2013
Zip 980052240 Suspend Date
County King Specialty 1 Roofing
Business Type Corporation Specialty 2 Unused
Parent Company JONES BOYS MAINTENANCE COMPANI
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
JONESBM006NUJONESBOYS
MAINTENANCE CO INC
Construction
Contractor
General
Unused
8/31/2000
4/5/2013
Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
JONES, RICHARD CONRAD
President
01/08/2010
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
13 INDEM CO
853392C
01/08/2010
Until Cancelled
$6,000.00
10/18/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
ATLANTIC CAS
INS CO
L1250011781
01/05/2011
01/05/2013
$1,000,000.00
01/04/2012
2
ATLANTIC CAS
INS CO
L1250011780
01/04/2010
01/04/2011
$1,000,000.00
01/07/2010
1
VICTORY INS CO
QSA0672540
01/08/2010
10/01/2010
$1,000,000.00
10/07/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
NCZIK00286
4/27/2010
18.27.100(1) RCW
CONSTRUCTION INFRACTION
Satisfied
$250.00
https: // fortress .wa.gov /lni /bbip /Print.aspx 05/16/2012