Loading...
HomeMy WebLinkAboutPermit D12-165 - WESTFIELD SOUTHCENTER MALL - AMERICAN EAGLE OUTFITTERS - STORAGE RACKSAMERICAN EAGLE OUTFIFI1ERS 610 SOUTHCENTER MALL D12 -165 City olkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 2061331 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 610 SOUTHCENTER MALL TUKW Suite No: Project Name: AMERICAN EAGLE OUTFITTERS Permit Number: D12 -165 Issue Date: 05/23/2012 Permit Expires On: 11/19/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: SCOTT DAVES Address: 140 SOUTH LAKES AV, SUITE 323 , PASADENA CA 91101 Contractor: Name: NATIONAL BUILDING CONTRACTORS Address: 1650 CARROLL AVE , SAINT PAUL MN 55104 Contractor License No: NATIOBC962RG Lender: Name: Address: Phone: 626- 585 -2931 Phone: 651- 222 -1859 Expiration Date: 12/07/2012 DESCRIPTION OF WORK: RACKING - 2 SETS OF 7 MOBILE SHELVING Value of Construction: $0.00 Fees Collected: $243.92 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -165 Printed: 05 -23 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be cox plie The granting of this p construction or the to this permit. Signature N N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Public: Non - Profit: N Public: Date: tcI !/) 12 ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. ork. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Print Name: Date:$ 3-a_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDI'T'IONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IBC -7/10 D12 -165 Printed: 05 -23 -2012 7: All electrical work shall be inspected anlikroved under a separate permit issued by tity of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC-7/10 D12 -165 Printed: 05 -23 -2012 CITY OF TUI(.L,A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building PerilNo. 171/,- — I (/ Project No. 1 Date Application Accepted: Date Application Expires: � 11-- (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 9202470010 Site Address: T ' Southcenter Mall, Tukwila WA 98188 Suite Number: B200 Floor: American Eagle Outfitters New Tenant: ❑ Yes ® ..No Tenant Name: PROPERTY OWNER Name: Westfield Corporation Address: 11601 Wilshire Blvd., Suite 1200 City: Los Angeles State: CA Zip: 90025 CONTACT PERSON - person receiving all project communication Name: Scott Daves / Permits Today Address: 140 South Lakes Ave., Suite 323 City: Pasadena State: CA Zip: 91101 Phone: (626) 585 -2931 Fax: (626) 792 -5777 Email: permitstoday @aol.com GENERAL CONTRACTOR. INFORMATION Company Name: Kenneth L. Butts Architects Company Name: r ltnt�0,1At O0, //�/ Ct `r. Address: Email: State: City: 0- nom' 1' Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:WpplicationslFontis- Applications On Line1201 I AppGeationsWermit Application Revised - 8- 9- 11.docv Revised: August 2011 bit ARCHITECT OF RECORD Company Name: Kenneth L. Butts Architects Architect Name: Kenneth L. Butts Address: 124 Stagecoach Rd City: Bell Canyon State: CA Zip: 91304 Phone: (8 18) 999 -4272 Fax: (8 18) 999 -4321 Email: ENGINEER OF RECORD Company Name: Kenneth L. Butts Architects Engineer Name: Kenneth L. Butts Address: same as above City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 DV ULi/l1v h rl.� K1Vi11 lIV r VKIVIA I 11.111 — ZU0- 431 -307U Valuation of Project (contractor's bid pr. $ 0V12 Existing piing Valuation: $ Describe the scope of work (please provide detailed information): wtO Q; (-? < LIP Ds OF Will there be new rack storage? 1 ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE P TECTION/HAZA US MATERIALS: Sprinklers it Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 6 No If `yes , attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line \2012 Applications\Fermit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existing • InteriorRemodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor r / (/ 2°d Floor Pi Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE P TECTION/HAZA US MATERIALS: Sprinklers it Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 6 No If `yes , attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line \2012 Applications\Fermit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Signature: AGENT: Print Name: S &&AcA4 /l,( e7 . V' Mailing Address: P 0 6fI?( S ( 7 H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Day Telephone: a ''„`Gk. S City Date: / Q — 360. -1r 3 r- (-St art State Zip ) Page 4 of 4 PUBLIC WORKS PERMIT INFOOIATION — 206 - 433 -0179 • Scope of Work (please provide detailed information): iNt 0 ( (e .( (47 (U i � 91 S P tS OF 7 Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ...Se Availability Provided ❑... Highline ❑ ...Valley View ❑ ... Renton Septic System: ❑ On -site Septic System — For on -site septic stem, provide 2 copies of a current septic design appro d by King County Health Department. ❑... Renton Submitted with Application (mark boxes which ply): ❑ .. Civil Plans (Maximum Paper Size —22" x 3 ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance ❑... Eas 0... Geotechnical Rep; ent(s) 0... Maintenance Ag ement(s) G Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑... Right -way Use - Profit for less than 72 hours 0... Righi -of- -way Use — Potential Disturbance Work in Flood Zone rm Drainage 0... Abandon ptic Tank ❑...Curb Cut ❑... Pavement Cut ❑... Loop d Fire Line ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension /public FINANCE INFORMATION /v Fire Line Size at Property Line ❑ .. Water Sewer Monthly Service Billing Name: WO # WO # WO # Private ❑ Private ❑ 1 (2) " WO # (2) " WO # \ ❑...Grease Interceptor ❑... Channelization 0... Trench Excavation 0... Utility Undergrounding ❑ .. Deduct Wate Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment (3) (3) eter Size " WO# " WO# Day Telephone: Mailing Address: City State Zip Water Meter R nd/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications'Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-165 Address: 610 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/11/2012 Applicant: AMERICAN EAGLE OUTFITTERS Issue Date: Receipt No.: R12 -01657 Payment Amount: $149.60 Initials: JEM Payment Date: 05/23/2012 09:43 AM User ID: 1165 Balance: $0.00 Payee: JOHN M BRETZKE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 012338B ACCOUNT ITEM LIST: Description 149.60 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $149.60 145.10 4.50 doc: Receipt -06 Printed: 05 -23 -2012 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-165 Address: 610 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/11/2012 Applicant: AMERICAN EAGLE OUTFITTERS Issue Date: Receipt No.: R12 -01567 Payment Amount: $94.32 Initials: BLH Payment Date: 05/11/2012 01:07 PM User ID: ADMIN Balance: $149.60 Payee: SHAWN MEYER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 657661 ACCOUNT ITEM LIST: Description 94.32 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 94.32 Total: $94.32 doc: Receiot -06 Printed: 05 -11 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Pro'ect: Type of Inspection: j Address: Arid/ (6 I D Ste� A- /rid Date Called: _ --_ Special Instructions: Date Wanted:J � --7 _- (��a�rm p:m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0-rf 0 Dater r7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee,must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule 'reinspection. PPbLIPSE ENGINEERING INC. Structural Calculations Steel Storage Racks Pipp PC Manual Carriage with Retail Shelving 4 copy for Pipp Mobile Storage Systems, Inc. American Eagle Outfitters Store #478 South Center Shopping Center - Space #200 Tukwila, Washington 9R138 JAN 13 2012 — REVIEWED FOR CODE COMPLIANCE APPROVED MAY 212012 Prepared For: American Eagle Outfitters 540 Keystone Warrendale, PA 15086 City of Tukwila WWULDMNG DIVISION EXPIRES 13 Please note: The calculations containe c resistance of the shelving racks, the fixed and mobile base supports, and the connection to the existing partition walls for both lateral and overturning forces as required by the 2009 International Building Code. These storage racks are not accessible to the general public. 155 NE REVERE AVENUE. SUITE A, BEND, OR 97701 PHONE: (541) 389 -9659 FAX: (541) 312 -8708 WWW .ECLIPSE - ENGINEERING.COM N C E bE-lk5 RECEIVED MAYi l 2012 _ PERMIT CENTER Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Tukwila, WA Pipp Mobile STEEL STORAGE RACK DESIGN 2009 IBC & 2010 CBC & ASCE 7 -05 - 15.5.3 Design Vertical Steel Posts at Each Corner : Shelving Dimensions: Total Height of Shelving Unit - ht:= 10.ft Width of Shelving Unit - w := 4.ft Depth of Shelving Unit - d := 1.50.ft Number of Shelves - N,:= 9 Vertical Shelf Spacing - 5,:= 10.0•in Shelving Loads: Maximum Live Load From Jeans (stacked 14 pairs tall and 3 wide): Weight of (1) Pair of Jeans - Wj := 1.40•Ib Weight of Jeans per shelf - Wt; := 3.14.Wt Load in psf - Wti Design Live Load on Shelf - Dead Load on Shelf - LL• :_ w•d LL := 11 .psf DL:= 2.0•psf Rolf Armstrong, PE kips := 1000.Ib Ib•ft -1 Rif;= Ib•ft -2 lb•ft- 3 si := 1000•Ib•in 2 W11 = 58.8 lb LLB = 9.8-psf rote: With 11 shelves, the floor oading will be max 85 psf, which s OK on 100 psf retail floor Section Properties of 3/4" x 1 9/16" x 16 Gauge Steel Channel : Modulus of Elasticity of Steel - Steel Yield Stress - Physical Dimensions of Channel : Channel Width - out -to -out - Channel Depth - out -to -out - Radius at Corners - Channel Thickness - Channel Width - CL - to - CL - Channel Height - CL - to - CL - Radius of Gyration in x and y - Section Modulus in x and y - Moment of Inertia in x and y - Full Cross Sectional Area - Length of Unbraced Post - Effective Length Factor - E := 29000 • ksi Fy:= 33•ksi b := 1.5625 • in h := 0.75•in Rc := 0.188•in t:= 0.0593.in bc:= b -0.5•t hc: =h - t rX := 0.4982 • in SX:= 0.0614•in3 IX := 0.0557 • in4 Ap := 0.2246 • in2 LX:= S= 10.in KX := 1.0 16 Gauge be = 1.5329 .in he = 0.6907 • in ry • = 0.3239 • in Sy := 0.0628 • in3 Iy • = 0.0236 • in4 Ly := S = 10•in K Y := 1.0 Lt:= S= 10.in Kt:= 1.0 1 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Section Properties Continued: Density of Steel - Weight of Post - Vertical DL on Post - Vertical LL on Post - Total Vertical Load on Post - Tukwila, WA Rolf Armstrong, PE psteel := 490•pcf Wp := psteeI.Ap•ht Pd := DL•w•.25•d•N + Wp P1:= LL•w•.25•d•N Pp := Pd + Pi Wp = 7.6426•Ib Pd = 34.6426 lb Pi = 148.51b Pp = 183.1426 • Ib Floor Load Calculations : Weight of Mobile Carriage: We := 90•Ib Total Load on Each Unit: ;= 4.Pp + We W = 822.57 lb Area of Each Shelf Unit: A„ := w.d.2 A„ = 12ft2 Floor Load under Shelf: PSF := A PSF = 68.5475 .psf Au NOTE: SHELVING LIVE LOAD IS LESS THAN 100 psf REQUIRED FOR RETAIL FLOOR LOADING This is considering the aisle area next to the shelf to help disburse the shelf load Find the Seismic Load using Full Design Live Load : ASCE -7 Seismic Design Procedure: Importance Factor - IE := 1.0 Determine Ss and Si from maps - Ss := 1.425 Determine the Site Class - Class D Determine Fa and Fv - Fa := 1.00 Determine SMS and SM1 _ SMS Fa•Ss SMS = 1.425 Determine SDS and SDI _ SDS 3 •SMS SDS = 0.95 Structural System - Section 15.5.3 ASCE -7: 4. Steel Storage Racks Total Vertical LL Load on Shelf - Total Vertical DL Load on Shelf - = 4.0 Rp := R W1:= LL•w•d no := 2 ap := 2.5 W p Wd := DL.w.d + 4. N Seismic Analysis Procedure per ASCE -7 Section 13.3.1: Average Roof Height - Height of Rack Attachment - hr := 24•ft z := 0•ft S1 := 0.488 F„ := 1.512 SM1 := Fv•S1 SM1= 0.7379 2 SDI := 3 •SM1 SDI = 0.4919 Cd := 3.5 Ip := 1.0 = 66 lb Wd = 15.3967 lb For Ground Floor 2 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Seismic Base Shear Factor - Shear Factor Boundaries - Tukwila, WA Rolf Armstrong, PE 0.4•ap•Sps z Vt:= Rp 1 + h r Ip Vtmin := 0.3•Sps•Ip Vtmax :_ •1.6•Sps•Ip A := if (Vt > Vtmax , Vtmax , Vt) Seismic Loads Continued : For ASD, Shear may be reduced - Seismic DL Base Shear - DL Force per Shelf : Seismic LL Base Shear - LL Force per Shelf : 0.67 * LL Force per Shelf : := if (Vt < Vtmin , Vtmin , Vt) Vt Vp := 1.4 Vtd := Vp•Wd•N Fd Vp•Wd Vu := Vp•W1•N F1:= Vp•WI F1.67 := 0.67•Vp•WI Vt = 0.2375 Vtmin = 0.285 Vtmax = 1.52 Vt = 0.285 V P = 0.2036 Vtd = 28.21 lb Fd = 3.13 lb Vti = 120.92 lb F1= 13.44Ib F1.67 = 9 lb Force Distribution per ASCE -7 Section 15.5.3.3: Operating Weight is one of Two Loading Conditions : Condition #1: Each Shelf Loaded to 67% of Live Weight Cumulative Heights of Shelves - H1 := .5•S + 1.5.S + 2.5.S + 3.5•S + 4.5•S + 5.5•S H2 := 6.5•S+ 7.5•S+ 8.5•S I := H1 + H2 Total Moment at Shelf Base - Mt := H • Wd + H .0.67.W1 Mt = 2012.1 ft • Ib Vertical Distribution Factors for Each Shelf - Total Base Shear - Vtotal Vtd + 0.67.Vd Vtota1 = Wd•0.5•S+ W1.0.67.0.5.S C1:= C1= 0.0123 Mt Wd•1.5•S+ W1.0.67.1.5•S C2 := C2 = 0.037 Mt Wd•2.5•S + W1.0.67.2.5•S C3 := C3 = 0.0617 Mt Wd • 3.5.S + W1.0.67.3.5 •S C4 := C4 = 0.0864 Mt 109.23 lb F1 := Cl•(Vtotal) F2 C2•(Vtotal) F3 C3•(Vtotal) F4 C4•(Vtotal) F1= 1.351b F2 = 4.05 lb F3 = 6.741b F4 = 9.441b 3 Eclipse Engineering, Inc. AEO Store #478 ,1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE Wd•4.5•S + WI.0.67.4.5•S C5:= C5= 0.1111 Mt Wd•5.5•S+ WI.0.67.5.5•S C6:= C6= 0.1358 Mt Wd.6.5.S + WI.0.67.6.5.S C7 := C7 = 0.1605 Mt Wd•7.5•S + WI.0.67.7.5•S C8:= M* Wd•8.5•S + WI.0.67.8.5•S Cg:= Mt C8 = 0.1852 F5 C5.(Vtotal) F6 C6.(Vtotal) F7 := C7•(Vtotal) F8 C8•(Vtotal) C9 = 0.2099 F9 := Cg•(Vtotal) C1 +C2 +C3 +C4 +C5 +C6 +C7+C8 +Cg= 1 Condition #2: Top Shelf Only Loaded to 100% of Live Weight F5 = 12.14Ib F6 = 14.83 lb F7 = 17.53Ib F8 = 20.23Ib Fg = 22.92Ib Coefficients Should total 1.0 Total Moment at Base of Shelf - Mta := (N — 1)•S•Wd + (N — 1)•S•WI = 542.64ft•Ib Total Base Shear - Vtotal2 Vtd + FI = 41.64 lb Wd.0.5.S+ 04/I.0.5•S Cia C8a Mta C1a = 0 Wd•(N — 1).S+ WI-(N — 1).S Mta C8a = 1 Condition #1 Controls for total base shear. Fia Cia4Vtotal2 F8a C8a'(Vtotal2) Fia = 0.49 lb F8a = 41.64Ib By Inspection, Force Distribution for intermediate shelves without LL are negligible. Ms 4'SAtd + Vtl) fbX:= Ms•SX 1 Fb:= 0.6•Fy Column Design in Short Direction : Bending Stress on Column - Allowable Bending Stress - Ms= 31.0688ft•lb fbx = 6.0721 •ksi OK Fb = 19.8•ksi 4 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE Find Allowable Axial Load for Channel Column : Allowable Buckling Stresses - 'rr2•E 7r2•E Qex.x 2 Oex.x = 710.4037 • ksi creX.y := 2 Kx • Lx Kv rx ry Distance from Shear Center - to CL of Web via X -axis Qex.y = 300.2753 • ksi crex if (o ex.x < crex.y, 0ex.x crex.y) crex = 300.2753 • ksi Distance From CL Web to Centroid - Distance From Shear Center to Centroid - Polar Radius of Gyration - t hc2 bc2 ec := ec = 0.2983 . in 4•Ix := 0.649•in – 0.51 xo := x + ec r0:= Jrx2 + ry2 + xo2 xc = 0.6193•in xo= 0.9177•in ro = 1.0933 • in Torsion Constant - j:= 3 •(2•b•t3 + h13) J = 0.00027•in4 Warping Constant -:= t•b3•h2 2•h•t 12 (3.b.t+ 6•b•t+ h•t CW = 0.00648 • in6 Shear Modulus - 2,:= 11300•ksi 1 '�2•E. Qt := G.3 + Qt = 80.4243 ksi Apr 2 /Kt 4)2 B = 0.2954 Fet = 66.9083 •ksi Elastic Flexural Buckling Stress - Fe := if (Fet < (rex, Fet, Qex) Fe = 66.9083.ksi Allowable Compressive Stress - Fn := if Fe > 2 , Fy• 1 – 4 F , Fe Fn = 28.931 •ksi e xo : =1– — ro )2 Fet := 1 2� [(�ex + at) – J (vex + at)2 – 4.0. vex vt] Factor of Safety for Axial Comp. - & := 1.92 5 Eclipse Engineering, Inc. AEO Store #478 1113/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE Find Effective Area - Determine the Effective Width of Flange - Flat width of Channel Flange - Flange Plate Buckling Coefficient - Flange Slenderness Factor - Effective Flange Width - Determine Effective Width of Web - Flat width of Channel Web - Web Plate Buckling Coefficient - Web Slenderness Factor - Effective Web Width - Effective Column Area - Nominal Column Capacity - Allowable Column Capacity - Check Combined Stresses - "IC 2•E•Ix Pcrx / 2 (Kx • Lx) Pcr lf(Pax < Pcry, Pcrx, Pcry) Magnification Factor - wf:= b- Rc -0.5•t kf := 0.43 1.052 wf Fn Xf :_ - � t E 0.22 1 pf 1 - Xf %f w f = 1.3449 • in Xf = 1.1492 pf = 0.7036 be := if (Xf > 0.673, pf•wf, wf) be = 0.9462 .in ww:= h- 2•Rc -t kw := 4.0 1.052 ww Fn xw := t E kw Pw 1 0.22 1 %w Xw he := if (Xw > 0.673 , pw, • ww , ww) Ae:= t.(he+ 2•be) Pn := Ae•Fn Pn Pa. —90 Pcrx =2x 105 lb Combined Stress: Pcry (Ky' Ly)2 'r2'E'Iy Pcr = 67548 lb �o' Pp a:= 1— ww = 0.3147 • in %w = 0.0882 pw = - 16.959 he = 0.3147 . in Ae = 0.1309 • in2 Pn = 3787 lb Pa = 1972 lb Pcry = 67548 lb = 0.9948 Cm := 0.85 Pcr Pp + Cm f bx - 0.3549 MUST BE LESS THAN 1.0 Pa Fba Final Design: 3/4" x 1 9/16" x 16ga CHANNEL IS ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS NOTE: P is the total vertical load on post, not 67% live load, so the design is conservative 6 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE STEEL STORAGE RACK DESIGN PER 2009 IBC & 2010 CBC & ASCE 7 -05 - 15.5.3 Find Overturning Forces : Total Height of Shelving Unit - Ht := ht = 10ft Width of Shelving Unit - w = 4ft Depth of Shelving Unit - d = 1.5ft Number of Shelves - N = 9 Vertical Shelf Spacing - S = 10.in Height to Top Shelf Center of G - htop Ht Not) = 10 ft Height to Shelf Center of G - h_ (N 2 1) S ho = 4.1667•ft From Vertical Distribution of Seismic Force previously calculated - Controlling Load Cases - Weight of Rack and 67% of LL -_ (Wd + 0.67.%).N W = 536.5506 lb Seismic Rack and 67% of LL - ,= Vtd + 0.67 Vri V = 109.2264 lb M1:= F1.0.5•S + F2.1.5•S + F3.2.5•S + F4.3.5•S + F5.4.5•S + F5.5.5•S + F7•6.5•S + F8.7.5•S M2:= F9.8.5•S Overturning Rack and 67% of LL - Weight of Rack and 100% Top Shelf - Wa := Wd.N + Wi Seismic Rack and 100% Top Shelf - Va := Vtd + Fi Overturning Rack and 100% Top Shelf - Ma Vtd . he + Fi • htop Controlling Weight - 2(4,:= := if ON > Wp , W , Wp) Controlling Shear - Vc := if(V > Va, V, Va) Controlling Moment - Mot := if(M > Ma, M, Ma) Tension Force on Column Anchor - T= aot — 0.60 •20 per side of shelving unit Shear Force on Column Anchor - L= if (T < 0•Ib, 0•Ib, T) Vc L USE: HILTI KWIK BOLT TZ ANCHOR (or equivalent) - USE 3/8"4) x 2" embed installed per the requirements of Hilti Ta := 1006•Ib For 2500psi Concrete M := M1+ M2 = 544.4ft•Ib Wa = 204.5706 lb Va = 41.6447 lb Ma = 251.9ft•Ib We = 536.551 lb Vc = 109.226 lb Mot = 544.45ft•lb T = 202 lb T = 201.999 lb V = 54.6 lb Allowable Tension Force - Allowable Shear Force - /:= 999•Ib Combined Loading - MUST BE LESS THAN 1.20 7 Eclipse Engineering, Inc. AEO Store #478. , ,1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE Strap Bracing on Backside of Shelving Units : Total Seismic Base Shear - Shear Force on Backside into Braces - Vc = 109.22641b Vc Vh := 2 Vh = 54.6132 lb Number of Shelf Bays Supported by Brace - Nb := 1 Each Shelf is Individually Braced Nib he 2 Tension Force into Brace - Tb := Nb Vb2 + Tb = 78.8602 lb w USE 0.75" x 16ga STRAPS Width of Strap - b5:= 0.75•in Thickness of Strap - t5:= 0.0545•in Area of Strap - As := bs•ts T b Tension Stress in Strap - ft := —As Allowable Tension Stress - Ft := 0.6.33•ksi As = 0.0409 • in2 ft = 1.93.ksi Ft= 19.8•ksi USE #10 SCREWS or RIVETS TO CONNECT STRAP TO FRAME : Shear Capacity of #10 Screw -:= 293•Ib Connecting to 16ga metal Number of Screws Required - Tb Ns: Vc Ns = 0.2691 USE: min (1) #10 SCREW or RIVET AT EACH END OF STRAP VERIFY HILTI BOLT CONNECTION FROM STRAP : h Tension Force from Brace - T„ := Nb •Vb • - T„ = 56.89 lb (Vertical Component) w Shear Force from Brace - (Horizontal Component) • Combined Loading - 1.0-Tv Ta Vh Nb•Vb Vh = 54.6132 lb 1.0•Vh – 0.11 MUST BE LESS THAN 1.20 Va 8 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE STEEL ANIT -TIP CLIP AND ANTI -TIP TRACK DESIGN Tension (Uplift) Force on each side - T_*. 201.99898 lb Connection from Shelf to Anti -Tip track: Capacity of 1/4" diameter bolt in 16 ga steel - Zc := 312•Ib if(T < 2•Zc, "(2) 1/4" Bolts are Adequate" , "No Good ") = "(2) 1/4" Bolts are Adequate" Use 3/16" Diameter anti -tip device Yield Stress of Angle Steel -= 36.ksi Thickness of Anti -tip Head - to := 0.090•in Width of Anti -tip Rod + Radius - br := 0.25•in Width of Anti -tip Head - ba := 0.490•in ba - br Width of Anti -tip Flange - La := 2 La = 0.12•in Tension Force per Flange leg - T1:= 0.5.T T1= 100.9995 lb Bending Moment on Leg - M1:= Tr 2La M1= 0.504997•ft•lb bat2 Section Modulus of Leg - Si := 6 Si = 0.0007 •in3 Mi Bending Stress on Leg - fb := S fb = 9.161•ksi f b Ratio of Allowable Loads - - 0.3393 MUST BE LESS THAN 1.00 0.75.Fy Width of Anti -Tip track - lam= 5.1.in Thickness of Aluminum Track - tt := 0.25-in Average Thickness Spacing of Bolts - Stb := 24.in L•tt2 Section Modulus of Track - St := 6 St = 0.0531 •in3 T•Stb Design Moment on Track - Na:= 8 M = 50.5ft•Ib for continuous track section Bending Stress on Track - f = S—t fb = 11.407 • ksi Allowable Stress of Aluminum - := 21•ksi ANTI - CLIP STEEL CONNECTION AND TRACK ARE ADEQUATE 9 Eclipse Engineering, Inc. AEO Store #478 1/.13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE Connection from Steel Racks to Wall Seismic Analysis Procedure per ASCE -7 Section 13.3.1: Average Roof Height - ham:= 24.0.ft Height of Rack Attachments - zb := 10.ft At Top for fixed racks connected to walls 0.4.ap•Sps Seismic Base Shear Factor - V�:= RP (1 Zb +2.h r Ip Shear Factor Boundaries - Nom= 0.3•Sps•Ip V ^= 1.6•Sps•Ip Vt,:= if(Vt > Vtmax, Vtmax, Vt) Vt := if (Vt < Vtmin , Vtmin , Vt� Seismic Coefficient - Vt = 0.4354 Number of Shelves - N = 9 Weight per Shelf - Wtf := 50•Ib Total Weight on Rack - WT := 4.Pp 0.7•Vt•WT Seismic Force at top and bottom - Connection at Top: Standard Stud Spacing - Width of Rack - Number of Connection Points - on each rack Force on each connection point - Capacity per inch of embedment - Required Embedment - For Steel Studs: Pullout Capacity in 20 ga studs 2 Sstud := 16.in w =4ft' Vt = 0.4354 Vtmin = 0.285 Vtmax = 1.52 Vt = 0.435 WT = 732.5706 lb Tv = 111.6407 lb Nc := floor w Nc = 3 Sstud Tv Fc N c lb Ws := 135• — in Fc ds:= W s Fc = 37.2136 lb ds = 0.2757 • in T20 := 83.1b For #10 Screw - Per Scafco MIN #10 SCREW ATTACHED EXISTING WALL STUD IS ADEQUATE TO RESIST SEISMIC FORCES ON SHELVING UNITS. EXPANSION BOLT IS ADEQUATE BY INSPECTION AT THE BASE 10 Eclipse Engineering, Inc. AEO Store #478 1/13/2012 Consulting Engineers Tukwila, WA Rolf Armstrong, PE STEEL STORAGE RACK DESIGN STEEL CHANNEL SECTION PROPERTIES W/O LIPS Channel Dimensions 3/4 x 1 9/16 x 16 gauge - Channel Flange Length - df := 1.5625 • in Channel Web Width - bw:= 0.75•in Channel Thickness - tom= 0.0598•in Radius at Corners -= 0.188.in Area of one Flange - Af := (cif — t) •t Area of Web - Aw := bw•t Total Area of Channel - At := 2.Af + Aw X -X Section Properties: df - t Distance to Flange CL - yfx := t + 2 Distance to Web CL Centroid of Channel - Dist - Flange CL to Centroid - Dist - Web CL to Centroid - Moment of Inertia of one Flange Moment of Inertia of Web - ywx:= 2 2•Af•Yfx + Aw•Ywx Yc = 2 Af + Aw Yxi yfx - Yc Yx2 Yc — Ywx t(df —t)3 Ifx 12 3 Iwx •- bw•t 12 Af = 0.0899•in2 Aw = 0.0448 • in2 At = 0.2246 • in2 yfx= 0.8111.in ywx = 0.0299 . in yc = 0.6551 in Yxi = 0.156•in yx2 = 0.6252 • in Ifx= 0.0169•in4 Iwx = 1.3365 x 10- 5 •in4 Using Parallel Axis Theorem - Moment of Inertia of Channel - 440 2.(Ifx + Af •Yx12) + (Iw( + Aw•yx22) Distance from Centroid to edge - cx := if (yc > df - Yc , yc , df - Yc) Section Modulus of Channel - Radius of Gyration - Ix = 0.0557.in4 cx = 0.9074 • in Sx = 0.0614•in3 rx = 0.4982 • in 11 Eclipse Engineering, Inc. AEO Store #478 Consulting Engineers Tukwila, WA Y - Y Section Properties : t Distance to Outer Flange CL - xf1 := bw — 2 t Distance to Near Flange CL - xf2 := 2 Centroid of Channel - �" Dist - Flanges to Centroid - x1:= xn . — Xc �df — t) •t3 Moment of Inertia of Flange - I. 12 t. bw3 Moment of Inertia of Web - 12 1/13/2012 Rolf Armstrong, PE xf1 = 0.7201 .in xf2 = 0.0299 . in xc = 0.375.in x1= 0.3451 • in Ify = 0.000027 •in4 IN,y = 0.0021 .in4 Using Parallel Axis Theorem - Moment of Inertia of Channel - I:= IWy + 2•(Ify + Af•x12) Iy = 0.0236.in4 Distance from Centroid to edge - cy := 2" cy = 0.375•in Section Modulus of Channel - ,= Iy Sy = 0.0628•in3 W Radius of Gyration -= y Ty = 0.3239.in At 12 Eclipse Engineering, Inc. Consulting Engineers AEO - Store #478 1/13/2012 Tukwila, WA Rolf Armstrong, PE Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4583 Longitude = - 122.25839999999998 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.425 (Ss, Site Class B) 1.0 0.488 (S1, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4583 Longitude = - 122.25839999999998 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 =FvxS1 Site Class D - Fa = 1.0 ,Fv = 1.512 Period Sa (sec) (g) 0.2 1.425 (SMs, Site Class D) 1.0 0.738 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4583 Longitude = - 122.25839999999998 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2 /3xSM1 Site Class D - Fa = 1.0 ,Fv = 1.512 Period Sa (sec) (g) 0.2 0.950 (SDs, Site Class D) Eclipse Engineering, Inc. Consulting Engineers AEO - Store #478 Tukwila, WA Fasteners (Screws and Welds) Screw Table Notes 1. Screw spacing and edge distance shall not be less than 3 x D. (D = Nominal screw diameter) 2. The allowable screw values are based on the steel properties of the members being connected, per AISI section 1/13/2012 Rolf Armstrong, PE iSSCAFCD. Steel Stud Manufacturing Ca. E4. 3. When connecting materials of different metal thicknesses or yield strength, the lowest applicable values should be used. 4. The nominal strength of the screw must be at least 3.75 times the allowable loads. 5. Values include a 3.0 factor of safety. 6. Applied loads may be multiplied by 0.75 for seismic or wind loading, per AISI A 5.1.3. 7. Penetration of screws through joined materials should not be less than 3 exposed threads. Screws should be installed and tightened in accordance with screw manufacturer's recommendations. Allowable Loads for Screw Connections (lbs/screw) Steel Thickness Mils Design (in) 18 0.0188 27 0.0283 30 0.0312 33 0.0346 43 0.0451 54 0.0566 68 0.0713 Steel Properties Fy (ksi) Fu (ksi) 45 45 45 Dia. = 0.216 (in) Shear Pullout Dia. = 0.190 (in) Shear Pullout Dia, = 0.164 (In) Shear Pullout 66 39 121 59 141 65 Dia. = 0.138 (In) Shear Pullout 60 33 111 50 129 55 Weld Table Notes 1. Weld capacities based on AISI, section E2. 2. When connecting materials of different metal thickness or tensile strength (Fu), the lowest applicable values should be used. 3. Values include a 2.5 factor of safety. 4. Based on the minimum allowance load for fillet or flare groove welds, longitudinal or transverse loads. 5. Allowable loads based on E60xx electrodes 6. For material less than or equal to .1242" thick, drawings show nominal weld size. For such material, the effective throat of the weld shall not be less than the thickness of the thinnest connected part. Allowable Loads For Fillet Welds And Flare Groove Welds Mil Design Thickness in. Yield ksi , Tensile ksi E60XX Electrodes lhs /ln 43 0.0451 33 45 609 54 0.0566 33 45 764 68 0.0713 33 45 963 97 0.1017 33 45 1373 118 0.1242 33 45 1677 54 0.0566 50 65 1104 68 0.0713 50 65 1390 97 0.1017 50 65 1983 118 0.1242 50 65 2422 Eclipse Engineering, Inc. Page 11 of 14 AEO - Store #478 1/13/2012 ESR11917 Consulting Engineers Tukwila, WA Rolf Armstrong, PE TABLEB-KB-TZ CARBON AND STAINLESS STEEL ALLOWABLE SEISMICTENSION (ASD), NORMAL-WEIGHT CRACKED CONCRETE, CONDITION B (pOutids)" 3 Nominal Anchor Diameter Embedment De Pill he (1n.) Con Cretb.CompressIveStrength2 fc ='2,500 pal Pc = 3,0 psi to = 4,0604301 rcA6;090 pal Ckirti On Steel Stainless -Steel Carbon` Steel Stainless steel Carb On' steel Stab* Nie steel 'Carbon steel Stainless steel 3/8 2 0 1 06 ... 1,037 1,102 4:130. liM 1;312 1;559 1,607 1/2 2 1,065 1212' 1;167 1,328 1;348 1;533 1,651. 1,878 3.1/4 2,178' 2;207 2,386, 2;418' 2,755 2,792 3,375 3,419 5/8 p 1/8 2,081 2,081 2;280 2;280, 2;632 2,632. 3,224 3,224. 4 3,01+ 2588 3,301 2-835' 3'812 3;274 4,669 4,010 3/4 3 3/4 2;736 3,594 2;997 3,937 3,460 4,546 '4;238 5,568 A 3/4 , 3,900 3,900 4,272 4,272 4.933. 4,933 6,042 6,042 For SI: 1 ibf = 4.45 N, 1 psi = 0.00689 MPa For pound-inch units: 1 mm = 0.03937 inches 'Values are or single anchors with no edge distance or spacing reduction. for other cases ; calculation of Rd as per ACI 318-05 and conversion to ASD In accordance With Section-4.2.1 Eq. (5)1s required. 2Values,are or normal weight concrete For sand-lightweight concrete, multiply values by 0.60. 'Condition B applies where supplementary reinforcement in conformance with ACI 318-05 Section D.4.4 is not Provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the strength reduction factors associated with Condition A may be used. TABLE 10-KB17 CARBONAND STAINLESS. -STEEL ALLOWABLE SEISMIC..SHEAR LOAD (ASD), (Pounds)1 Nominal Anchor. Diameter Allowable Steel, Capacity, Seismic Shear CarbOri.Steel ,Stalnli3ini Steel 3/8 999 1;262 • 1/2 2,839 3,049 5/8 4,678 5,245 ..3/4 6,313 ei477 For St1 Ibf=4.45'N 'Values are or single anahois with no edge distance or spacing reduction due to concrete failure.' • t'tFiet# GUUROCAW1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -165 DATE: 05 -11 -12 PROJECT NAME: AMERICAN EAGLE OUTFITTERS SITE ADDRESS: 610 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Div Division Public Works n My\ N /A- Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05-15-12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 06 -12 -12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name NATIONAL BUILDING CONTRACTORS UBI No. 601990646 Phone 6512221859 Status Active Address 1650 Carroll Ave License No. NATIOBC962RG Suite /Apt. License Type Construction Contractor City Saint Paul Effective Date 12/7/2004 State MN Expiration Date 12/7/2012 Zip 55104 Suspend Date County Out Of State Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NBCGEC1011QC N B C GENERAL CONTRACTORS INC Construction Contractor General Unused 11/3/1999 11/27/2004 Archived Business Owner Information Name Role Effective Date Expiration Date CORCORAN, WILLIAM BRIAN Owner 12/07/2004 Bond Amount Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 North American Spec Ins Co 2146429 09/30/2011 Until Cancelled $12,000.00 10/25/2011 4 BANCINSURE INC BIWA24216A 11/01/2005 Until Cancelled 11/05/2011 $12,000.00 12/02/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 Co cinnatilns EPP0068513 03/14/2011 03/14/2013 $1,000,000.00 03/14/2012 11 0010 CAS INS BKA53721993 03/14/2010 03/14/2011 $1,000,000.00 03/25/2010 9 AMERICAN FIRE & CASUALTY BKA53721993 03/14/2009 03/14/2010 $1,000,000.0003 /31/2009 8 INDIANA INS BKA53721993 03/14/2008 03/14/2009 $1,000,000.00 03/19/2008 7 WESTFIELD INSURANCE CO TRA3998774 03/14/2007 03/14/2008 $1,000,000.00 04/10/2007 6 WESTFIELD INS TRA3998774 03/14/2006 03/14/2007 $1,000,000.00 03/20/2006 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 07 -2- 03590 -1 GAMBLE CONST SERVICES & DEMO InterPlead: No SPOKANE Date: 08/16/2007 Amount: $15,000.00 Date: Amount: $0.00 Dismissed Date: Amount: https://fortress.wa.gov/lni/bbip/Print.aspx 05/23/2012 TENANT AMERICAN EAGLE OUTFITTERS, INC. 77 HOT METAL STREET PITTSBURGH, PA 15203 PHONE: 412-432-3300 FIELD REPRESENTATIVE J.P. MORABITO PHONE: 724-779-5271 JMORABITO@AE.COM LANDLORD WESTFIELD CORPORATION, INC. 2800 SOUTHCENTER SEATTLE, WA 98188 TENANT COORDINATOR SCOTT PRIESTER PHONE: 206-802-6070 A A* CONSULTANT PRO-MOTION TECHNOLOGY THERESA SWEET PHONE: 248-560-0534 SECURITY CONSULTANT CHECKPOINT SECURITY SHANDA DUKES PHONE: 952-227-5380 SENSORMATIC MIKE GIOSA (PRIMARY) PHONE: 215-946-8118 GARY SCOTT (SECONDARY) PHONE: 724-263-6305 SIGN CONSULTANT HANOVER SIGN 1771 PROGRESS AVE COLUMBUS, OH 43207 JEANNIE BILLER PHONE: 1-800-888-4870 SIGN INNOVATION 514 GERMAN STREET 1 HARMONY, PA 16037 RAY ROCCON PHONE: 724-452-8699 ARCHITECT KENNETH L. BUTTS, ARCHITECT 124 STAGECOACH ROAD BELL CANYON, CA 91307 PHONE: 818-999-4272 FAX 818-999-4321 PROJECT INFORMATION PROJECT DESCRIPTION : TENANT IMPROVEMENT - CLOTHING STORE USE GROUP CLASSIFICATION : M MERCANTILE OCCUPANCY LOAD CAPACITY: SALES AREA (5,187) x 1 PERSON/30 SF = 173 PERSONS STOCKROOM (q65) x 1 PERSON/300 SF = 3 PERSONS TOTAL OCCUPANCY LOAD = 176 PERSONS FIRE SUPPRESSION SYSTEM: FULLY SPRINKLERED CONNECTED TO MALL'S MAIN. (SPRINKLER DRAWINGS TO BE SUBMITTED FOR PERMIT BY SPRINKLER CONTRACTOR.) AREA ANALYSIS AREA DESCRIPTION SQUARE FOOTAGE SALES AREA FITTING ROOMS STOCK ROOM TOILET ROOM(S) EGRESS CORRIDOR OFFICE 4,715 472 716 PERCENTAGE BREAKDOWN 76% 8% 12% 1% 3% N/A 82 167 • N/A TOTAL GROSS AREA 6,152 100% INTERIOR TENANT FINISH SOUTHCENTER SHOPPING CENTER 707 SOUTH CENTER MALL TUKWILA, WA 98188 STORE NUMBER: 0478 SPACE NUMBER: 200 SITE PLAN LEVEL 1 OF 3 ././■■••■■•' AMERICAN EAGLE OUTFITTERS SPACE NO. 200 • .• ■ •, ^ ■•, ■ ■ , • • • 't • • • • • • • • • ' , • . . . • • • ' • REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1_ 2012 City of TkiiIa BUILDING bMSION LSEPARATE PERMIT REQUIRED FOR: kMechanical !Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. IMPORTANT NOTE: • ALL CONTRACTORS 4 SUB--CONTRACTORS SHALL BE RESPONSIBLE TO REVIEW ENTIRE DOCUMENT SET, INCLUDING ALL DISCIPLINES (ARCH, MEC.I. ELEC, PLUMB, rt.) REGARDLESS OF BASE TRADE, TO ENSURE TWAT ALL COMPONENTS ARE PROPERLY CONSTRUCTED. THE MAXIMUM PENALTY ALLOWED B" LAW WILL BE ENFORCED UPON FINGER-POINTING FOR MISSED CONSTRUCTION DEMILS. • IF CONFLICTING DETAILS OR CONDITIONS ARE FOUND WITHIN 1I-115 DRAWING Se, G.C. SHALL BE RESPONSIBLE TO NOTIFY TENANT REP. IMMEDIATELY. G.C. SHALL NOT PROCEED WITH FURTHER WORK UNTIL RECEIVING PROPER DIRECTION FROM TENANT REP. IMPORTANT NOTE: JOB SUPERINTENDENT SHALL, UPON COMPLETION OF THE PROJECT, PROVIDE TENANT WITH NO LESS THAN THE FOLLOWING DIGITAL PHOTOGRAPHS; MINIMUM OF THREE (3) PICTURES OF EACH STOREFRONT FACADE, ONE (I) 'HEAD ON SHOT AND ONE (I) FROM EACH CONCOURSE APPROACH; MINIMUM OF ONE (1) PICTURE OF EACH SALES AREA ELEVATION, FOUR (4) MINIMUM PER 'ROOM', TWELVE (12) MINIMUM FOR ENTIRE SALES AREA; MINIMUM OF ONE (1) PICTURE OF EACH INTERIOR FITTING ROOM ELEVATION, INCLUDING VESTIBULE, PASSAGE, SEATING AREA AND SILVER TEXTURED CEILING AREA (IF APPLICABLE); MINIMUM OF FOUR (4) PICTURES OF THE STOCKROOM ELEVATIONS SHOWING SHELVING, ALL EQUIPMENT, LADDER SYSTEM (IF PROVIDED) AND TOILET ROOM(S); MINIMUM FOUR (4) INTERIOR PICTURES OF PUBLICLY ACCESSIBLE TOILET ROOMS (IF APPLICABLE); PICTURES OF FIRE CORRIDOR AND ELECTRICAL PANELS; MINIMUM REQUIRED PICTURES FOR SPECIAL DETAILS AND ELEMENTS AS SO SPECIFIED THROUGHOUT THE PLANS (NOTED WITI4 ). -105 SUPERINTENDENT IS NOT PERMITTED TO VACATE THE SITE UNTIL SUCH PICTURE S ARE PROVIDED TO TENANT VIA THE "STORE PHOTOS" SECTION OF TENANT'S DRAWING DOWNLOAD WEB SITE. PLEASE CONTACT G.C. FOR WEB SITE ACCESS INFORMATION. IMPORTANT NOTE: WHERE APPLICABLE, ALL PREVIOUS TENANT SURVEY DATA HAS BEEN POSTED TO THIS TENANT'S DRAWING DOWNLOAD SITE. G.C. 91-1ALL REVIEW PREVIOUS TENANT SURVEY DATA AS REQUIRED TO ENSURE ALL ASPECTS OF CONSTRUCTION ARE ACCOUNTED FOR REGARDLESS OF INFORMATION CONTAINED WITHIN THESE DOCUMENTS. - - _ NOTE: EXISTING CONSTRUCTION (S1-10IAIN GI-10STED) TO REMAIN. REFURBISH AS INDICATED/RE.QUIRED. • :Tr DRAWING INDEX ARCI-IITECTURAL A.0,00I COVER SHEET A.0.010 GENERAL NOTES A.0.020 PINISW * MATERIALS LEGEND A.0.030 ARCHITECTURAL SPECIFICATIONS A.0.050 BARRICADE DETAILS A.0.00 DEMOLITION FLOOR PLAN A.0.05 DEMOLITION CEILING PLAN A.0.100 FLOOR PLAN A.0.106 FIXTURE PLAN A.0.150 TOILET ROOM DETAILS A.0.200 REFLECTED CEILING PLAN A.1.300 STOREFRONT ELEVATIONS A.1.400 PLAN SECTION AT STOREFRONT A.1.401 PLAN SECTION AT STOREFRONT A.1.402 PLAN SECTION AT STOREFRONT A.1.450 PREFAB. ENTRY PORTAL DETAILS A.1.500 STOREFRONT SECTIONS A.1.50I STOREFRONT SECTIONS A.1.510 STOREFRONT SECTIONS DETAILS A.1.600 INTERIOR ELEVATIONS A.1.700 PREFAB PILASTER DETAILS A.1.701 PREFAB PILASTER DETAILS A.1.710 COLUMN AND MISCELLANEOUS DETAILS A.1.720 FITTING ROOM ELEVATIONS t DETAILS A.1.730 DOOR ELEVATIONS it DETAILS A.1 .731 DOOR ELEVATIONS DETAILS A.1.740 PREFAB. DISPLAY CASE ASSEMBLY 'A' DETAI A.1.741 PREFAB. DISPLAY CASE ASSEMBLY '13' DETAI A.1.743 PREFAB. DISPLAY CASE ASSEMBLY 'D' DETAI A.1.800 SIGN SHOP DRAWINGS A.1.50I SIGN SHOP DRAWINGS A.I.q00 SHELVING DETAILS A.1.q0I SHELVING DETAILS • A.1.q10 STOCKROOM FIXTURE DETAILS A.1.q20 SALES AREA/F. IR1-1. FIXTURE DETAILS A.1.430 AUDIONIDEO DETAILS A.1.140 A.1.c141 CASH AND WRAP DETAILS CASH AND WRAP DETAILS 3405 KENNETH L. BUTTS STATE OF WASHINGTON 'JAN 2 4 2012 • • ELECTRICAL .0.01Q ELECTRICAL SPECIFICATIONS E.0.100 ELECTRICAL REFLECTED CEILING PLAN E.0.200 ELECTRICAL FLOOR PLAN E0.300 ELECTRICAL NOTES AND SCHEDULES E.0.400 CALL BUTTON DETAILS MECHANICAL M.0.010 MECHANICAL SPECIFICATIONS 1'1.0.011 MECHANICAL SPECIFICATIONS M.0.020 MECHANICAL CALCULATIONS M.0.100 MECHANICAL. PLAN M.0,200 MECHANICAL DETAILS PLUMBING P.0.100' PLUMBING SPECIFICATIONS 4 DETAILS Fin PROTECTION (SPRINKLER) FP.0.100 • . • T 0.100 T 0 200 T.0.306 T.0.400 T 0 500 T.0.600 TO.7oo, T.0.800 FIRE PROTECTION PLAN 4 DETAILS EMS COVER SWEET EMS FLOOR ::PLAN/EMS DATA LINK RISER DIAGRAM DETAIL INTERFACE PANEL :Hoc CONTROLLER INPUT DETAILS HVAC, CONTROLLER DETAILS OUTPUTS GE SOFTINIRED CONTACTOR PANEL SpFTWIRING DETAILS/SCHEDULES PIR WIRING DETAILS FILE Permit No- an -eview appooval s stied effewand does not i2rovat cf COliStaletiOn hnri74 e &proved Fieki Copy am! ed: LLA 1 b5 RECEIVED Drawing No MAY 1 1. 2017 PERMIT CENTER STOCK SHELVING (MOBILE AND FIXED). SEE SHEET A.1.g00 FOR MORE INFORMATION (TYP) EXISTING COMPUTER CABINET TO REMAIN 87' -0" 4' -6" EMPLOYEE LOCKERS r lEXISTING AUDIO CABINET 1 1 1 --1 1 1 — _I RECEIVING/PROCESSING AREA E3B -IO E38 -1O E38 -10 E3B -10 E38 -10 ANTI -TIP BRACKET FOR STOCK —� SHELVING, SEE DETAIL ON % EE'L. kl.f4k IY-1' ) E35 -10 EXISTING BENCHES TO REMAIN. —� TOP WITH NEW SEAT. SEE SHEET A.1.720 FOR DETAILS (TYP) EXISTING GRAPHIC FRAME TO REMAIN (TYP) EXISTING COATHOOKS TO REMAIN (TYP) EXISTING MIRROR TO REMAIN (TYP) EBB -10 E3B -10 E45 -10 E48 -10 MC -3285 E48 -10 E48 -10 MC -3285 E48 -10 E48 -10 MC -3285 E4B -10 E48 -10 MC -3285 E48 -10 E48 -10 MC -3285 o CD 0 WI u ;r f E4A -IO E4A •10 MC -324q E4A -IO E4A --10 MC -324q E4A -1O :11 E4A -I0 MC -3249 E4A -IO I� E4A -IO MC -324q E4A -10 E4A -10 MC -3249 u+� EAR srox -1 CABINET DETACHABLE MIRROR AND MIRROR BRACKETS. TOP OF MIRROR SHALL BE q6" A.F.F. DETACHABLE MIRROR AND MIRROR BRACKETS. TOP OF MIRROR SHALL BE q6" A.F.F. CASH $ WRAP - TURN. BY TENANT, INST. BY G.0 SEE SHEET A.1.q40 FOR DETAILS. DENIM BAR/GRAPHIC FRAME CLUSTER - RELOCATED COATHOOK ASSEMBLY MOUNTED AT 4' -0" A.F.F. TO CENTERLINE OF HOOKS NOTE: G.C. SHALL STRUCTURALLY BRACE ALL "END CAP" SHELVING AS REQUIRED TO WITHSTAND POSSIBLE IMPACT FROM ROLLING SHELVING. NNTE: SEE SHEET A.I.g00 FOR DETAILS OF ALL STOCKROOM SHELVING SHELVING COMPONENTS - FURN. BY TENANT, INST. BY G.C. NOTE: SEE SHEET A.1.g10 FOR DETAILS OF ALL MISC. STOCKROOM FIXTURES FURN. BY TENANT, INST. BY G.G. NOTE: PRIOR TO INSTALLATION OF STOCKROOM SHELVING 4 STOCKROOM ACCESSORY ITEMS, G.C. SHALL VERIFY THAT ALL STOCKROOM COMPONENTS CAN BE INSTALLED AS SHOWN ON THIS DRAWING. IF FIELD CONDITIONS PROHIBIT INSTALLATION AS SHOWN, OR PRESENT OPPORTUNITIES FOR EXPANSION, G.C. SHALL NOT CONTINUE WITH ANY INSTALLATION AND NOTIFY TENANT FIELD REP IMMEDIATELY. NEW MIRROR MOUNTED OPPOSITE BENCH 0 6' -8" A.F.F. SEE A.1.720 FOR TYPICAL DETAILS NEW 4' -0" x 2' -0" BENCH RELOCATED EXISTING SMALL GRAPHIC FRAME MOUNTED AT 4' -611" A.F.F. TO BOTTOM OF FRAME. SHELVING END TREATMENT LEGEND PREFAB PUNCHED METAL BRACKETS WITH FOLDING SHELF. SEE DETAIL A/A.I.g00 AND /OR A/A.2.g00 (TIT) PREFAB PUNCHED METAL BRACKETS (PARTIAL WEIGHT). SEE DETAIL A /A.I.g00 AND /OR A/A.2.g00 (TYP) PREFAB PUNCHED METAL BRACKETS (FULL HEIGHT). I SEE DETAIL B /A.I.g00 AND /OR B /A.2.g00(TYP) LADDER HANG BRACKET. SEE DETAIL C/A.1.g00 AND /OR C /A.2.g00 (TYP) , NOTE: SEE SHEET A.I.g20 FOR DETAILS OF ALL MISC. SALES /FITTING ROOM FIXTURES FURN. BY TENANT, INST. BY G.C. t FIXTURE PLAN SCALE: 1/4" 1' - 0" SQUARE FOOTAGE AREA SQ. FT. SALES AREA 4, 715 76% FITTING ROOMS 472 8% STOCK ROOM 716 12% TOILET ROOM(5) 82 1% EGRESS CORRIDOR 167 3% OFFICE N/A • N/A J TOTAL. 6,152 100% DENIM BAR/GRAPHIC FRAME CLUSTER - RELOCATED COATHOOK ASSEMBLY MOUNTED AT 4' -0" A.F.F. TO CENTERLINE OF HOOKS NOTE: G.C. SHALL STRUCTURALLY BRACE ALL "END CAP" SHELVING AS REQUIRED TO WITHSTAND POSSIBLE IMPACT FROM ROLLING SHELVING. NNTE: SEE SHEET A.I.g00 FOR DETAILS OF ALL STOCKROOM SHELVING SHELVING COMPONENTS - FURN. BY TENANT, INST. BY G.C. NOTE: SEE SHEET A.1.g10 FOR DETAILS OF ALL MISC. STOCKROOM FIXTURES FURN. BY TENANT, INST. BY G.G. NOTE: PRIOR TO INSTALLATION OF STOCKROOM SHELVING 4 STOCKROOM ACCESSORY ITEMS, G.C. SHALL VERIFY THAT ALL STOCKROOM COMPONENTS CAN BE INSTALLED AS SHOWN ON THIS DRAWING. IF FIELD CONDITIONS PROHIBIT INSTALLATION AS SHOWN, OR PRESENT OPPORTUNITIES FOR EXPANSION, G.C. SHALL NOT CONTINUE WITH ANY INSTALLATION AND NOTIFY TENANT FIELD REP IMMEDIATELY. NEW MIRROR MOUNTED OPPOSITE BENCH 0 6' -8" A.F.F. SEE A.1.720 FOR TYPICAL DETAILS NEW 4' -0" x 2' -0" BENCH RELOCATED EXISTING SMALL GRAPHIC FRAME MOUNTED AT 4' -611" A.F.F. TO BOTTOM OF FRAME. SHELVING END TREATMENT LEGEND PREFAB PUNCHED METAL BRACKETS WITH FOLDING SHELF. SEE DETAIL A/A.I.g00 AND /OR A/A.2.g00 (TIT) PREFAB PUNCHED METAL BRACKETS (PARTIAL WEIGHT). SEE DETAIL A /A.I.g00 AND /OR A/A.2.g00 (TYP) PREFAB PUNCHED METAL BRACKETS (FULL HEIGHT). I SEE DETAIL B /A.I.g00 AND /OR B /A.2.g00(TYP) LADDER HANG BRACKET. SEE DETAIL C/A.1.g00 AND /OR C /A.2.g00 (TYP) , NOTE: SEE SHEET A.I.g20 FOR DETAILS OF ALL MISC. SALES /FITTING ROOM FIXTURES FURN. BY TENANT, INST. BY G.C. t FIXTURE PLAN SCALE: 1/4" 1' - 0" SQUARE FOOTAGE AREA SQ. FT. SALES AREA 4, 715 76% FITTING ROOMS 472 8% STOCK ROOM 716 12% TOILET ROOM(5) 82 1% EGRESS CORRIDOR 167 3% OFFICE N/A • N/A TOTAL. 6,152 100% NOTE:, EXISTING CONSTRUCTION (SW -IOWN GHOSTED) TO REMAIN. REFURBISH AS INDICATED /REQUIRED. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21. 2012 City of Tukwila BUILDING DIVISION 1 RECEIVED MAY 112012 PERMIT CENTER c�h rg ismi .0 .0 REGISTERED ARCHITECT KENNETH L. BUTTS STATE OF WASHINGTON JAN 24 Zo' 1 0_ I No. 478 Drawn by: A roved Drawing No. A.0.106 fl- in 0 I MOBILE STORAGE SYSTEMS, INC 2916 WILSON, sW WALKER,, MI 4%44-761.4 t+N' (Soo) asp -i n FA* (so 7n1-to n1L1 LE.H50M NTTPd/MW.PIPPM001LE GOM INSTALLATION INSTRUCTION PREPARED FOR: AMERICAN EAGLE OUTFITTERS FOR TECHNICAL ASSISTANCE DURING BUSSINESS 1 -TOURS (8AM - 5PM EST) 1- 800 - 234 -7477 EXT 4076 JIM RAPER 1 -800 -234 -7477 EXT 4064 ANDREW AUSTIN AFTER BUSSINESS HOURS 1 -600- 234 -7477 EXT 55 YOUR MESSAGE WILL BE SENT TO AN ON -CALL PROJECT MANAGER WHO WILL PROMPTLY RETURN YOUR CALL. ALL PIPP CARRIAGES ARE EQUIPPED WITH THE TOLL FREE NUMBER FOR URGENT INSTALLATION OR REPAIR MATTERS. STEP #4 INSTALL ANTI -DRIFT MECHANISM VIEW SHOWN IN UNLOCKED POSITION 1. THE POST -LOCK BRAKES ARE SHIPPED IN A SEPARATE ACCESSORY BOX. 2. THE CHANNELS ARE PRE - ASSEMBLED WITH A MOUNTING STUD INSTALLED. NOTE: WASHER AND NUT INSTALLED ON STUD. (NUT MOUNTED BACKWARDS FOR SHIPPING). 5. REMOVE NUT AND WASHER AND INSTALL BRAKE ASSEMBLY. STUD GOES THROUGH LOWER SLOTTED HOLD IN BRAKE ASSEMBLY. 4. BRAKE SEATS ON CHANNEL OVER STUD. INSTALL 4 END SCREWS, INSTALL WASHER AND 1/4 20 STAR/WASHER NUT AND TIGHTEN. 5. ADDITIONAL SLOTTED HOLES AND END EXTRUDED HOLE TO BE USED IN SECURING CORNER OF SHELVING TO CORNER BRAKE ASSEMBLY. NOTE: POSITION AND SECURE SHELVING AT BRAKE CORNER FIRST. EIRAKE DETAIL NO SCALE POSmVE CARRIAGE LOCK TRICK 1N -TRACK ANTI -TIP TRACK TYPICAL "2 TRACK" MOBILE SYSTEM IN -TRACK ANTI -TIP ALUMS POSITIVE CARRIAGE LOCK TRACK "2 TRACK" CARRIAGE DETAIL A.1.g01 No SCALE STEP #1 CONFIRM PARTS TO PACKING LIST PARTS DESCRIPTION Jx X sY' ANCHOR DOLT NEAR DLI T TRACK UNINSTLAITIVIT 1.1' DUMETNt Y'X2'NAIL-IN ANY OR ALL OP THE ICNA D* PARTS MAT DE NC.UPW N TOUR SONDE COMM ALL PARTS AND GUAM= TO TM PAWNS LIST wag ODONNING NIITALLATX L Casaletb INT MASSNART . MD SIL71 MD SOLT 12 N -TRACK ANTI -1111 TRAM • NEAR' DUTT DO STOP SSE TEK SCRIM (MIK SOOLT NTH Ir „tAIMIPP POSITIVE LOOKING ORME TRACK RUDER WIPER CROSS ORAOON DETAIL FARTS LIST NO SCALE. POSITIVE LOCKING BRAKE SYSTEM POSITIVE harms maw PG•GARpME ANNIOLT 1 'TRACE AIN7'SLT MIN NflSIAL MON CO NN • MASTER LINK INSTALLED AT FACTORY TRACK: POSITION POSI -LOCK TRACK ON THE AISLE SIDE OF THE MOBILE SYSTEM. POSITION CHAIN SLOT TO THE AISLE. THE CHAIN I5 APPROXIMATELY 4 INCHES SHORTER THAN THE TRACK. IT HAS BEEN PRE - ASSEMBLED WITH ONE FIXED END AND ONE ADJUSTABLE END. DETERMINE WHAT SIDE OF THE SYSTEM SIDE THERE IS ACCESS WITH AN ALLEN WRENCH FOR ADJUSTMENT. YOU WILL FEED THE CHAIN THROUGH THE OPPOSITE END. AFTER THE TRACK 14A5 BEEN STAGED FOR INSTALLATION (BEFORE USING THE ANCHORS) FEED THE CHAIN THROUGH THE TEE SLOT. WITH THE CHAIN THROUGH THE TRACK, SECURE THE TRACK WITH ANCHORS PROVIDED. SEAT THE NON - ADJUSTING TEE IN THE CHAIN SLOT. PULL THE CHAIN TOWARDS THE ADJUSTING END. INSTALL ADJUSTER TEE NUT AND 1/4 -20 ALLEN SCREW. SNUT ALLEN SCREW UNTIL TENSION I5 EXHIBITED ON THE CHAIN. NOTE: DO NOT OVER TIGHTEN THE CHAIN IN TRACK. CHAIN MUST BE ABLE TO MOVE EASILY SIDE TO SIDE WITHIN THE CHAIN POCKET IN THE TRACK. BRAKE DETAIL A.1.g01 No SCALE TYPICAL "3 TRACK" MOBILE SYSTEM STEP #2 INSTALL STATIONARY SHELVING 1. INSTALL STATIONARY SHELVING AT ONE END (WHERE APPLICABLE). 2. START BOTTOM SHELF AT 3" OFF FINISHED FLOOR. 3. FASTEN TOP AND BOTTOM SHELVES PERMANATELY TO STANDARDS. 4. FASTEN ALL STATIONARY SHELVING TO WALL. FIXED SHELVING DETAIL SEE NOTE 5 NO SCALE STEP #5 IN -TRACK ANTI -TIP (OPTION) THE GUIDE IS DESIGNED TO 8E INSERTED INTO THE TRACK AFTER THE TRACK I5 IN THE APPROXIMATE LOCATION, BUT PRIOR TO COMPLETELY SECURING IT TO THE FLOOR. THE SYSTEM IS SHIPPED COMPLETELY ASSEMBLED, HOWEVER, IF THE MOUNT ASSEMBLY CANNOT BE INSERTED INTO THE TRACK, IT I5 POSSIBLE TO REMOVE AND RE- INSTALL THE MOUNT ASSEMBLY. THE MOUNT ASSEMBLY MUST SE PLACED IN THE ORIGINAL FACTORY LOCATION. THE SYSTEM WILL NOT WORK IF THE MOUNT ASSEMBLY IS NOT PLACED PROPERLY. SECURE THE SHELVING TO THE CARRIAGES WITH INSTALLER SUPPLIED HARDWARE. THRUST WASHER -EZI50 FLANGED HUSHING-F/140 ANGLE- ALUORO 2- BOLT- CARI55_ 04-204 GRS) 2- WASHER PLAIN -MACES CARRIAGE CHANNEL- ALUI00 PIPP INTRACK ANTI -TIP -~0 MOUNT ASSY CAIi330-1 HEAVY DUTY TRACK (PHDT) WITH STEEL UNDERLAYMENT THE PIPP IN -TRACK ANTI -TIP SHOWN ABOVE WILL BE SHIPPED WITH THE HEAVY DUTY TRACK SHOWN TO THE RIGHT. CONNECT THE HEAVY DUTY TRACK USING THE UNDERLAYMENT AS A GUIDE AND SECURE TO THE FLOOR THROUGH THE MID -TRACK ANCHOR HOLES. F1 ANTI -TIP DETAIL A.1.g01 PIPP HEAVY DUTY TRACK NO SCALE POSITIVE CARRIAGE LOCK TRACK IN- TRACK ANTI -TIP ALUMS "3 TRACK" CARRIAGE DETAIL NO SCALE STEP #3 INSTALL TRACK (STAGGER JOINTS) ALIGN ASSEMBLED TRACK PARALLEL TO WALL OR AISLE, WITH APPROXIMATELY 2 "CLEARANCE FROM ANY OBSTACLE. USING THE HOLES IN THE TRACK AS A GUIDE, DRILL 1/4" HOLE'S INTO CONCRETE FLOOR DEEP ENOUGH FOR THE END STOP FASTENERS. CLEAN CONCRETE DUST FROM HOLE. HAMMER THE FASTENER'S THROUGH THE END STOP AND TRACK INTO FLOOR. CONFIRM JOINTS ARE STILL PROPERLY SEATED, AND TRACK I5 STRAIGHT. DRILL HOLE'S FOR END STOP AT OPPOSITE END OF TRACK. HAMMER FASTENER'S THROUGH END STOP. MAINTAINING CAREFUL ALIGNMENT, INSTALL MID -TRACK FASTENERS. 2' SPACING FROM wAI I ANCHOR BOLT END STOP 1Y' NAIL -IN END STOP STEEL UNDERLAYMENT ATTACHED TO TRICK STEEL UNDERLAYMENT OUT SACK 5' FOR FUTURE ADDITIONS MID -TRACK ANCHOR HOLE dettiti4ipir._ MID -TRACK ANCHOR HOLE STEEL UNDERLAYMENT EXTENSION STEEL UMrERLAYMENT CUT SACK 5' HEAVY DUTY TRACK ALIGN UNDERLAYMENT EXTENSION WITH CONNECTING TRACK. HAVE AN ASSISTANT GENTLY TAP THE END OF THE TRACK UNTIL SECTIONS ARE SEATED FLUSH. ALIGN REMAINING TRACK PARALLEL TO FIRST TRACK USING WHEEL CENTERS. ENSURE WHEEL I5 CENTERED IN THE CHANNEL: ANCHOR ON END OF THE TRACK. • TEST PARALLELISM BY ROLLING SEVERAL CARRIAGES ALONG THE TRACK RUN USING FULL BODY WEIGHT. TO CONFIRM PARALLELISM MAKE SEVERAL TRACK TO TRACK MEASUREMENTS ALONG EACH RUN. - CARRIAGES SHOULD ROLL FREELY WITH MINIMUM LATERAL WHEEL MOVEMENT. -THE TRACK ENDS SHOULD BE SQUARE AND ALIGNED. CONFIRM TRACK JOINTS ARE FULLY SEATED. ANCHOR END STOPS THROUGH TRACK WITH END STOP FASTENERS AS ABOVE. ANCHOR MID -TRACK FASTENERS. CO TRACK DETAIL STEP #6: ATTACH SHELVING TO CARRIAGES ATTACH SHELVING TO MOBILE CARRIAGE USING (1) *12 TEKS SCREW AT EACH CORNER. ATTACH UPRIGHT THROUGH HOLE IN CORNER PLATE WITH #12 TEK SCREWS. ATTACH UPRIGHT THROUGH HOLE IN CORNER PLATE WITH #12 TEK SCREWS. SHELVING DETAIL ATTACH UPRIGHT THROUGH HOLE IN CORNER PLATE WITH #12 TEK SCREWS. ATTACH UPRIGHT THROUGH HOLE IN CORNER PLATE WITH #12 TEK ;SCREWS. No SCALE SEE DETAIL G /A.1.4101 SHELVING DETAIL SEE DETAIL G/A.1.901 No SCALE REVIEWED-FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of Tukwila BUILDING DIVISION UPRIGHT OR FIXED SHELVING UNIT NOTE: ANCHOR ALL FIXED UNITS WITH SCREWS AT EACH UPRIGHT TO WALL MOUNTED HORIZONTAL FURRING STRIP LOCATED AT TOP OF FIXED UNITS. ATTACH STEEL ANGLE AT BOTTOM OF EACH UPRIGHT 1/4" X 2" X 2" STEEL ANGLE SECURED TO SLAB W/ 3 /8 "DIA. X 2 1 /4p POWER -BOLT PER ICC REPORT NO. ER -5225. (TYP. AT EACH SHELF UPRIGHT) FIXED SHELVING FLOOR CLIP DETAIL RECEIVED MAY 11 2012 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SWEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO T1-HS PROJECT. 41 r4 O E-' L � W E4 E-� 0 E-4 MAO .off w E - 4 . 8 . c.. 40 ch 441 C/DU W� N X00 N M 0 N 0 0 m 00 en N a� 3405 REGISTERED ARCHITECT +rr -% N H L. BUTTS STATE OF WASHINGTON AN 2 4 2011 4 W CI L74-4 ki k. `,' V z 00 W F J M"4-SZ u..1 r� = V p (1) 4 s W 0 Z_ o< 0 ,_x AL It U ° 0 Ws § (1) (n Store No. 47a Drawn by: Approved Drawing No. A.1.901 — STORE CHAIN CODE I— SHELVING LENGTH CONFIGURATION SERIES CODE FSHELVING HEIGHT E4A -10 E4A -10 E4A -10 E4A -10 MC -3237 �31- 0 "/4' -0 "� FIXED SHELVING UNIT ^ 31- 0 "/4' -0" �c- :o I I L NOMINAL CARRIAGE DIMENSIONS MOBILE CARRIAGE MOBILE SHELVING UNIT SHELVING /CARRIAGE KEY GENERAL NOTES: • SEE SHEET IA.0.1301 FOR SHELVING LAYOUT • SEE SHEET IA.1.g01' FOR MANUFACTURER'S INSTALLATION INSTRUCTIONS • INSTALL TRACK PER MANUFACTURER'S INSTRUCTIONS. TRACK MUST BE LEVEL (USING SHIMS AS REQ'D.) TO INSURE PROPER OPERATION. MAINTAIN 2" MINIMUM CLEARANCE BETWEEN EDGE OF TRACK AND WALL. (SEE SHELVING DETAIL C/A .I.g01) • INSTALL SHELF UNITS ON MOBILE CARRIAGE. SHELF UNIT MUST BE SECURED TO UNDER CARRIAGE USING ONE TEK SCREW IN EACH CORNER. (SEE SHELVING DETAIL G /A.1.g01) • INSTALL BRAKES ON ALL MOVEABLE CARRIAGES PER MANUFACTURER'S INSTRUCTIONS. (SEE SHELVING DETAIL E/A.1 .901) • INSTALL TWO BUMPERS BETWEEN EACH MOBILE UNIT 71 1/2" FROM BOTTOM IN PREDRILLED HOLES. (SEE SHELVING DETAIL K/A.1.g01) • DOUBLE X BRACES ARE REQUIRED ON MOBILE UNITS ONLY. FIXED UNITS REQUIRE SINGLE X BRACE. (SEE SHELVING DETAL 44/A.1 .q01) • TOP AND BOTTOM SHELVES TO 8E PERMANENTLY FASTENED IN PLACE USING TWO TEK SCREWS AT EACH END T44RU CROSS RAIL. (SEE SHELVING DETAIL G /A.1.c101) • ALL BACK TO BACK SHELF UNITS MUST BE FASTENED TOGETHER USING AT LEAST FOUR TEK SCREWS PER VERTICAL UPRIGHT. (SEE SHELVING DETAIL H /A.1.g01) • ATTACH HANDLE 44" A.F.F. +1- TO CENTER ON MOBILE UNITS ONLY. • USE 2 1/2" LEAD DRIVE PINS ON MOBILE TRACK WITH CHAIN (SEE SHELVING DETAIL E/A.1.g01) • USE POWER BOLTS ON TRACK WITH ANTI -TIP "I" TAB. (SEE SHELVING DETAIL - F /A.1.g01) • ALL BACK TO BACK SHELF UNITS WILL HAVE PLASTIC MESH SECURED ON THE BACK OF ONE UNIT (WITH METAL STRIPS AT THE TOP AND BOTTOM AND "ZIP TIED" EVERY 16" THROUGH THE CUT OUT) BEFORE UNITS ARE JOINED. • CONTRACTOR TO CONSULT TENANT ONSITE CONSTRUCTION REPRESENTATIVE REGARDING PLACEMENT OF WARNING PLACARDS. NOTCH 59 NOTCH 54 NOTCH 49 NOTCH 44 NOTCH 60 NOTCH 58 NOTCH 34 NOTCH 12 NOTCH 1 • 1 V V M MM • MM RUBBER BUMPER o (TYP.) b G.C. TO SECURE BRACKETS WITH TWO #12 TEK SCREWS (TYP) NOTCH 34/35 NOTCH 29/30 DRY ERASE BOARD HANG BAR PREFAB PUNCHED METAL BRACKET MOUNTING DETAIL A.I.g00 SCALE: 1/2 ".1' -0" (PARTIAL HEIGHT) A SERIES NOTCH 59 NOTCH 54 NOTCH 4q NOTCH! 44 NOTCH 39 NOTCH 34/35 NOTCH 29/30 NOTCH 60 NOTCH 51 NOTCH 44 NOTCH 37 NOTCH 30 NOTCH 23 NOTCH 16 NOTCH NOTCH 1 NOTCH 19 NOTCH 14 PREFAB PUNCHED METAL 5 BRACKET MOUNTING DETAIL A.1.g00 SCALE: 1/2 "ir1' -0" (FULL HEIGHT) RUBBER BUMPER 0 (TYP. ) 13 SERIES NOTCH 44 0 G.C. TO SECURE LADDER HANG BRACKET WITH TWO #12 TEK SCREWS NOTCH 60 NOTCH 58 NOTCH 39 NOTCH 20 NOTCH 1 PREFAB LADDER HANG BRACKET MOUNTING DETAIL A.1.g00 SCALE: I/2 "Is1' -O" N C SERIES HANG BAR (7TP.) RUBBER BUMPER o ( .) o REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2012 City of Tukwila BUILDING DIVISION t1,1 (0 RECEIVED MAY 112012 PERMIT CENTER NOTE: DETAILS, NOTES, AND /OR SPECIFICATIONS ON THIS SHEET NOT LISTED ALPHABETICALLY OR NUMERICALLY HAVE BEEN PURPOSELY OMITTED AND DO NOT PERTAIN TO THIS PROJECT. 3405 REGISTERED ARCHITECT TH L. BUTTS STATE OF WASHINGTON JAN 242018 • V1 W E PT-4 lu Ou W F < (D 1,-5Q �♦' 35 Ws 3 <(?)12- Store No. 47B Drawn by: Approved Drawing No.