HomeMy WebLinkAboutPermit D12-168 - DUPONT - TENANT IMPROVEMENTDUPONT
13028 INTERURBAN AV S
D12-168
City or Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.'l'ukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 0004800017
Address: 13028 INTERURBAN AV S TUKW
Suite No:
Project Name: DUPONT
Permit Number: D12 -168
Issue Date: 06/13/2012
Permit Expires On: 12/10/2012
Owner:
Name: EPROPERTY TAX INC DEPT #207
Address: PO BOX 4900 , SCOTTSDALE AZ 85261
Contact Person:
Name: DAVID KEHLE
Address: 1916 BONAIR DR SW , SEATTLE WA 98116
Contractor:
Name: C P CONSTRUCTION SERVICES LLC
Address: PO BOX 1148 , LAKE STEVENS WA 98258
Contractor License No: CPCONPC920NH
Lender:
Name:
Address:
Phone: 206 - 433 -8997
Phone: 425 - 345 -0830
Expiration Date: 09/28/2012
DESCRIPTION OF WORK:
NEW TENANT: REMOVE EXISTING NON - BEARING WALLS, INSTALL NEW NON - BEARING WALLS, NEW DOORS, RELOCATE
LUNCH CABIBET, MODIFY EXISTING CEILING AND LIGHTING AS REQUIRED.
Value of Construction: $23,500.00 Fees Collected: $905.73
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0008
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -168 Printed: 06 -13 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and xami ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie with, whether specified herein or not.
The granting of this permit does not p u . e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: ' ✓."!�' Date:
Print Name: `. y , � /l \jur / (,fi
J r'„ ; f
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
6: Readily accessible access to roof mounted equipment is required.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
doc: IBC -7/10
D12 -168 Printed: 06 -13 -2012
Building Code or International Residential it, International Mechanical Code, Washingtetate Energy Code.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: ** *FIRE DEPARTMENT CONDITIONS * **
15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
doc: IBC -7/10
D12 -168 Printed: 06 -13 -2012
26: Maintain sprinkler coverage per N.F.P.• Addition/relocation of walls, closets or parts may require relocating
and /or adding sprinkler heads. (IFC 901.4)
27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327).
29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2328)
30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC
104.2)
31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
33: New and existing buildings shall have approved address numbers, building numbers or approved building identification
placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers
shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a
minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)
34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and
#2328)
35: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IBC -7/10
D12 -168 Printed: 06 -13 -2012
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No. 1 )--- t (0 Fr
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: I'(�''(�J, b I Isl IIer403b t
V �- 4b .
Tenant Name: l �f`i
PROPERTY OWNER
Company Name:
Name: is-7,,
Q�IQ �
Name: % oe!v' e
Address:« b�W p,R,,f 'oz. pe
Contr Reg No.: Exp Date:
Address: / 4 I 7
° &,€ vim.
6uiti., 'fii 0
City: leislt
State: RA.
Zip:
CONTACT PERSON — person receiving all project
communication
Company Name:
Name: is-7,,
Q�IQ �
City: State: Zip:
Address:« b�W p,R,,f 'oz. pe
Contr Reg No.: Exp Date:
City: State: h6 Zip 1
11 p,, ,
Phone: , 4.3 ,8 q Fax:ft,lika. pea q
Address:
Email: tflieve e abehte Zy.cm , co.
State:
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
H:Upplicatiom\Fornts- Applications On Line \2011 Applcations\Permit Application Revised - 8- 9-11.docx
Revised: August 2011
bh
King Co Assessor's Tax No.: too4t cov 1*
Suite Number: 114 Floor: 1
New Tenant: 1K Yes ❑..No
ARCHITECT OF RECORD
Company Name: i \I l 0 k iA k i r1
Architect Name: n il o rite
Address: Kite `Z pa
. 1..6
City: 1fl, State: )L . Zip :/Jllia� (y
_ �O 6
Phone,//�11►� ,v Fax•
Iixo .433 -tom[} : t7(o,1.4listaq
Email: Ad') le Q dlsei(-ea oil . Gnw\
ENGINEER OF RECORD
Name:
4 j�
I`FPS
Company Name: 14)4c
Address:
Engineer Name:
Address:
State:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
4 j�
I`FPS
Address:
City:
State:
Zip:
Page 1 of 4
• •
BUILDING PERMIT INFORMATION — 206 -431 -3670
Valuation of Project (contractor's bid price): $
Describe the scope of work (please provide detailed information):
Eekleta 11-114C1 1490 - 515a104 IlJbus,, iN5 bu.' 4 v 1,644 - lily V6uh,
MEN Cam, Veit Obigi,.t, r( FC1at et 61004 dub *6
Existing Building Valuation: $ 1 LUOLI
Vi5tRI WO.
Will there be new rack storage? ❑ Yes. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ' Automatic Fire Alarm ❑ None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If ' yes', attach list of materials and storage locations on a separate 8 -1/2 "x II " paper including quantities and Material Safety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:1Applications \Forms- Application On Lme12011 ApphcationsWumit Application Revised - 8- 9- 11.dotx
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1" Floor
/► / 5/ $
!!��
Zfr
r
V Y O
2
D
2nd Floor
3`d Floor
Floors thou
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ' Automatic Fire Alarm ❑ None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If ' yes', attach list of materials and storage locations on a separate 8 -1/2 "x II " paper including quantities and Material Safety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:1Applications \Forms- Application On Lme12011 ApphcationsWumit Application Revised - 8- 9- 11.dotx
Revised: August 2011
bh
Page 2 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN ' ' OR ORIZED AGENT:
Signature:
Print Name: rki0 III I l u�
Mailing Address: VI IC W &. 122, /w
H:\Apphcaiioi Fomts- Apphcanons On Lute \2011 ApplicationsTennil Application Revised - 8- 9- 11.dowc
Revised: August 2011
bb
Date: ('\21 \
Day Telephone: /IV -43� </
City State Zip
Page 4 of 4
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 0004800017 Permit Number: D12-168
Address: 13028 INTERURBAN AV S TUICW Status: APPROVED
Suite No: Applied Date: 05/21/2012
Applicant: DUPONT Issue Date:
Receipt No.: R12 -01855
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $550.70
Payment Date: 06/13/2012 09:27 AM
Balance: $0.00
BRAD JURVAKAINEN, CP CONSTRUCTION SRVCS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 11316G
ACCOUNT ITEM LIST:
Description
550.70
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 546.20
640.237.114 4.50
Total: $550.70
doc: Receipt -06 Printed: 06 -13 -2012
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 0004800017 Permit Number: D12-168
Address: 13028 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 05/21/2012
Applicant: DUPONT Issue Date:
Receipt No.: R12 -01636
Initials: WER
User ID: 1655
Payment Amount: $355.03
Payment Date: 05/21/2012 11:25 AM
Balance: $550.70
Payee: DAVID KEHLE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 03220D
ACCOUNT ITEM LIST:
Description
355.03
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 355.03
Total: $355.03
doc: Receiot -06 Printed: 05 -21 -2012
INSPECTION RECORD:
Retain a copy with permit -
INSPECTION NO. :PERMIT NO:.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila: WA 98188 t t .(206).431 -3670'
Permit Inspection Request Line (206) 431 -2451
Project:
j)LJ1°6N 1
Type of Inspection: t
K,r4..A A'FtJ -1,is
Address:
/30
X—C/ %S /,J
Date Called:
Special Instructions:
Date Wanted:7
'ram'
; Pith-
Requester:
Phone
Approved per applicable codes.
Corrections required prior to approval:
COMMENTS:
�-
I ki 1 C.v ii i
Inspect
Dater
F-7 REINSPECTION FEE REQUIRED., Prior to next inspection;. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedulereinspection..,
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. • PERMIT NO.
•-CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 Vas (206) 431-367
Permit Inspection Request Line (206) 431-2451
VIZ-1(1Y
Project:: ..)T,.._
• DU P o
Type of Inspection: N
5) jg- . 6-E-; L4
Address: • 1 ,
1 2) 61...Er-- m4Tr3 A4A-ry
Date Called:
Special Instructions:
',.i/ •
.
Date Wanted:.
( ern.
Requester:
Phone No:
415
-345
-43-00
•
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Date.-7
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paidat 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD ;; �.,,
Retain a copy with permit,, 2_ _ cg
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 R' (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
Project:n
Type o spA- i1 ; : e
Ad , rs:_
_ -.g -
Date Called:
Special Instructions:
Date Wanted:
— Z6Y--/
!a
p.m.
Requester:
Phone
_ 34 .
(v .-
0 0
U Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Inspector:
Date:V
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION \NO..' PERMIT NO.
CITY'OF'..TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 rt., (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
4/2 — / ('8
Project: -
Type of Inspection: /
Address:
/ja 7RZ(t ?e4/!/
Date Called:
Special Instructions :y.;c 12,/
?iv,'rb. L _ r'1IN115 fr11r41 61.'/‘
..Ci)C9 67 /-d/
Date Wanted:.
a.m .
Requester:
Phone No:
`/25 -S45---6,5z1
0
Approved per applicable codes. Corrections required prior to approval. ,
COMMENTS:
r
Dater
ri REINSPECTION. FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project:
D-jou'--\
Sprinklers: Y
Date: '7._4 _/ a
Type of Inspection:
S ✓& F 1 h a t, F;,, r,„, I
Address: lz, )4 1 w at-
Suite #: i�,-■
S4
Au 5
Coact Person:
Special Instructions:
Pre -Fire:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
pr./
COMMENTS:
S ✓L ■
0cc-
Needs Shift Inspection: AJ
Sprinklers: Y
Date: '7._4 _/ a
Fire Alarm:
Al
Hood & Duct: Ai
Monitor: '
Pre -Fire:
Permits:
Occupancy Type:
l
Inspector:
A-1,-,.<i I
Date: '7._4 _/ a
Hrs.:
1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10 .
T.F.D. Form F.P. 113
I
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
is -5 —ic8
bra -
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Project:
b4-(Pc)
Sprinklers: !
Type of Inspection:
Su Cou _r---
Address: 130012
•
Suite #.
-: ioic
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers: !
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
S 01—
Date: ,6/
// z
Hrs.:
1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
2009 Washington State Energ Code Compliance Forms for Nonresidential and Multifamil
Envelope Summary
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential
Project Info
Project Address P116/4r1
(psi
C-Fipplicant Name: �4 Ip {;�� �,,��.1'��
Applic nt Address: rL r map,12
- pplicant Phone: l (p 433 A� Lt '
PDescription
10 New Building ❑ Addition
Alteration
PI Compliance Option
ee Decision Flowchart (over) for qualifications)
Occupancy Group
!,. Nonresidential 0 Multifamily Residential
Climate Zone
' 'i, Climate Zone 1 0 Climate Zone 2 ( See
Fenestration Area Calculation
Total Fenestration Electronic version: these values are automatic
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area
Roofs - Single Rafter CO , __
Semi - Heated Path
0 yes Allowable if project meets all requirements as defined in section 1310.2.
, no calculated separately from other conditioned spaces. Limited to reducec
and qualifying thermostat.
Envelope Requirements (enter values as applicable)
Minimum Insulation R- values
Roofs - Insulation Above Deck
Roofs - Metal Building pE
''FINED FOR
Roofs - Single Rafter CO , __
• t i ,
Roofs - Attic and All Others A"-:..
.
Walls - Mass
Walls - Metal Building
Walls - Steel Framed
mit
Walls - Wood Framed and Other
Floors -Mass
Floors - Steel Joist
Floors - Wood Framed and Other
Maximum F- factors
Slabs -on -Grade - Unheated
Slabs -on -Grade - Heated
Notes: L Prescriptive Ell Performance
Nt) et-4)14413o 410aore
Envelope Requirements
Vertical Fenestration
Non -Metal Frame
Metal Frame
Entrance Door
Skylights - Without Curb
Skylights - With Curb
Opaque Doors - Swinging
Opaque Doors - Non -Swir
Vertical Fenestration
Non -North
North
Skylights
WSE(
ally t•
Only
wall i
RECEIVED
MAY 212012
PENT CENTER
2009 Washington State energy Code Compliance t-orm tor Nonresidential and Multitamily Residential
Interior Lighting Summary.
LTG -INT
2009 Washington State Energy Code Compliance Forms for Nonres ntial and Multifamily Residential
Revised November 2010
Project Info
Project Address VM 5—J
Date 6y„
I p.,
1Ue -h I LIT z e AVE� „ Olt 124-
For Building Department Use
���
pm.r.r Ra, r n
Applicant Name:
Applicant Address:
• j 0 / . . , fall
I(� i t4 pa (j. ttt, uu0 clew +�
��
Applicant Phone: "G5'.lp . c 53 -EAA 1..
Project Description
❑ New Building [] Addition rie Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions I [J No changes are being made to the lighting and space use not changed
(check appropriate box - sec. 1132.3) Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor plan /room #)
Occupancy Description
Allowed
Watts per ft2 **
Gross Interior
Area in ft2
Allowed x Area
** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
Proposed Lighting Wattage
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
BUILDIN I DIVISION
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. 7 -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, Tamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track
multiplied by 50, or as applicable. the wattage of current limiting devices or of the transformer. For low voltage track lighting list the
transformer rated wattage.
3. List all fixtures. For exempt lighting, note section and exception number. and leave Watts /Fixture blank.
VelDarit IS05111-1(4
ba,i(96
RECEIVED
MAY 212012
PERMIT CENTER
•
PERVITCO
PLAN REVIEW /RO
•
1NG SLIP
I_
ACTIVITY NUMBER: D12 -168 DATE: 05 -21 -12
PROJECT NAME: DUPONT
SITE ADDRESS: 13028 INTERURBAN AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
EPARTMENTS:
Ili ding Division
'Public W k Structural
ire Prevention
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 05-22-12
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
DUE DATE: 06 -19-12
Approved with Conditions )—(I/ Not Approved (attach comments) ❑
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople ?ter Friendly Page
•
Page 1 of 2
General /Specialty Contractor
A business registered as a construction contractor with L &1 to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name C P CONSTRUCTION SERVICES LLC UBI No. 602844469
Phone 4253456500 Status Active
Address 811 87Th Ave Se License No. CPCONPC920NH
Suite /Apt. License Type Construction Contractor
City Lake Stevens Effective Date 8/8/2008
State WA Expiration Date 9/28/2012
Zip 98258 Suspend Date
County Snohomish Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company JURVAKAINEN COMPANY LLC
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
CASCAPP964PM
CASCADE
PACIFIC
PAINTING LLC
Construction
Contractor
Painting /Wallcovering
Unused
10/14/200410/17
/2012
Active
CLASSPW033JW
CLASSIC
POWER WASH
& PAINTING
Construction
Contractor
Pressure Washing
Painting/Wallcovering
4/16/1997
4/16/2000
Archived
CLASSPW044JP
CLASSIC
PRESSURE &
WNDW WSHNG
Construction
Contractor
Pressure Washing
Unused
4/17/1996
4/16/1997
Archived
CPCONCS933BH
CP
CONSTRUCTION
SERVICES LLC
Construction
Contractor
General
Unused
1/8/2007
1/8/2009
Expired
CASCAPPOO1K1
CASCADE
PACIFIC
PAINTING
Construction
Contractor
Pressure Washing
Painting /Wallcovering
5/21/2000
7/1/2006
Re-
Licensed
Business Owner Information
Name
Role
Effective Date
Expiration Date
JURVAKAINEN, JILL ELIZABETH
Agent
09/29/2010
JURVAKAINEN, RANDY ALLEN
Partner /Member
08/08/2008
JURVAKAINEN, BRADLEY DEAN
Partner /Member
08/08/2008
CASCADE PACIFIC PAINTING LLC
Partner /Member
08/08/2008
JURVAKAINEN ENTERPRISES LLC
Partner /Member
08/08/2008
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amour
1
DEVELOPERS SURETY
& INDEM CO
794694C
07/02/2008
Until Cancelled
$12,000.0
Assignment of Savings Information No records found for the previous 6 year period
https: // fortress .wa.gov /lni /bbip /Print.aspx
06/13/2012
PARCEL NO.
0004800011
SCOPE OF UJOIRK
REMOVE EXISTING NON SEARING WALLS, INSTALL NEW NON BEARING WALLS, NEW
DOORS, AND RELOCATE LUNCH CABINET, MODIFY NE EXISTING CEILING AND
LIGHTING AS REQUIRED.
LEGAL DESCRIPTION
POR LEWIS C C DC ' 31 POR OF C C LEWIS DONATION CLAN NO 31
TOW POR OF STEPHEN FOSTER DONATION CLAIM NO 38 IN
SECTIONS 10,11,14 t 15 11UP 23 RANGE 4 - BAAP BEARING
N40- 01 -05W 920.15 FT FROM A MONUMENT AT PT OF INTSN OF
CURVE ON C/L OF DUWAMISH - RENTON J1.NCTION RD BEING
APPROX 1000 FT E 4 20 FT S OF QUARTER CORNER BETWEEN
SECTIONS 14 415 11-1N 49 -24.00 W 835 FT ON A LINE PLT 4 150 FT
NELY CF C/L OF DUWAMISH- RENTON JUNCTION RD TAP BEARING N
S1 -44 -55 E 199,11 FT FR POINT OF CURVE ON C/L OF DUWAMISN -
RENTON JUNCTION RD, SD PT OF CURVE BEING APPROX 1200 FT N
4 440 FT W OF QUARTER CORNER BETWEEN SECTIONS 14 4 15 tH S
40-30-001U 20 FT TO NELY MON OF RAJ OF PUGET SOUND
ELECTRIC RAILWAY TH N 49.24 -00 W 98029 FT TO FOB T14 5
49 -24 -00 E 400 FT TAI N 40 -36 -00 E 190 FT TN N 49 -24 -00 W
400 FT TH 540 -36 -00 W 190 FT TO POD -- AKA LOT 10F CITY
OF 'NO LA f3DRY LINE ADJ NO 91- 4 -131.A RECORDING NO
9105231162
BUILDING & SITE STATISTICS
— BUILDING CODE:. .IBC 2003
— BUILDING TYPE OF CONSTRUCTION: V —B FULLY SPRINKLERED
— OCCUPANCY GROUP' B
— ZONING: MI
— BUILDING AREA
TOTAL BUILDING AREA= 15,119 S.F.
— TENANT AREA BEFORE IMPROVEMENTS:
OFFICE= 2,878 S.F.
TOTAL= 2,878 S.F.
— TENANT AREA AFTER IMPROVEMENTS:
OFFICE= 2,878 S.F.
TOTAL= 2.878 S.F.
—OCCUPANT LOAD:
'OFFICE= 2,578 S.F. i 100= 28
TOTAL= 28
VINGITY MAP'
a rrit...11,11,C. L1ivrn.1,,a*.'vSri .19171,1"110 0.11u
01,7,1. nr+ru
L. lrlely1111,
o o
of
co ao
cNI
-�.r•-■
Q 0
N N
L&J
Q X
soloAf
r,
Witmer
SITE
SCALE: 1:100
SEPARATE PERMIT
REQUIRED FOR:
IgMechanical
Electrical
tg Plumbing
a Gas Piping
FILE COPY
912---Itot ,
Permit No.
Plan review approval Is subject to enlorS and omisorls.
Approval of construction documents does not authorize
the violation of any adopted code or odnance. Receipt
of approved Fold Copy and is lowledged
By
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
C :\Documents and Settings\AJl Users1DocumentssCAD11987- 198918704- 81DUPONT 130281C
21/2012 9:50:56 AM
REMOVE EXISTING WINDOW
REMOVE EXISTING WALL
REMOVE EXISTING COUNTER AND SINK (REUSE)
REMOVE EXISTING DOOR AND CLOSET
ICE
EX OFFICE
EX. OFFICE
u
—4
1!
11
u
n
-,i
u
EX. OPEN
OFFICE
i
I 1
u
n
EX. LUNCH
1
3- -'--{a i-I rl F'-- -C=_=."'
1 .' .-w! v
v.
' 1
:II I ,;
1
LJ,
�
Ex. OFFICE
EX. OFFICE
•
REMOVE PARTIAL HEIGHT WALL
REMOVE OFFICES
REMOVE EXISTING COUNTER
AND CA5INET
NORTH
FLOOR PLAN: DEMO
SCALE: 1/8'I : 1 0"
DEMO NOTES:
1 REMovE EXISTING WALLS AND DOORS AS SHOWN
2. PATCH EXISTING FLOOR, WALLS AND GE111NG AT DEMO U10fdG.
3. REMOVE EXISTING UNUSED LOW VOLTAGE WIRING AND GA6ELING
4. GAP ANY ELECTRICAL TO ABOVE CEILING IN J -BOX, MARK WIN PANEL AND CIRCUIT
5. REUSE DOORS AS PASSIBLE
6. REIMOYE FINISHES FOR NEW FINISHES (vERIFY WITH LANDLORD).
ENEFW CODE NOTES
1) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED
2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE
3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES
INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS.
4) MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT.
5) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO
EXTERIOR WINDOWS
LEGEND
•
A
Q
EXISTING WALL
NEW WALL PER SCHEDULE
NEW DOOR
EXISTING DOOR
ILLUMINATED EXIT SIGN AND PATHWAY
LIGHT W/ BATTERY BACK -UP.
NEW PATHWAY LIGHTING
LW BATTERY BACK -UP.
FOUR -PLEX OUTLET
DUPLEX OUTLET
WALL TELEPHONE OUTLET AND DATA,
I'LIDRING, CONDUIT AND PULL STRING ONLY.
DEDICATED
SWITCH
RIESTROOM LIGWtN•G FIXTURE
PAINT B1.A
UJALL, Tsrpgs
3 "X2SGA. STL. STUD a 24" O.C. WALL TO SUSPENDED CEILING, 5/8" GYP. BD,
BOTH 5IDE8, SOUND 'INSULATE
INFILL 3 1/2" X 25 GA STEEL STUD WITH 5/8" GYP BD EACH SIDE, TWER"IAL
INSULATION RILL THICK, MATCH STUD WALL EACH SIDE,
REMOVE EXISTING GRID AND LIGHTS
NEW WALL MOUNTED FLUORESCENT LIGHTS
MAX. WATTAGE To MATCH EX. LIGHTS REMOVED
ROOM SCHEDULE
1 -5 FLOOR; CARPET
10•13 BASE. RUBBER BASE
WALL: GYP. BD (PAINTED EE)
CEILING: E)( SUSPENDED CEILII
8,S
FLOOR: REMOVE CARPET ADD VCT
BASE: NEUJ RUBBER SASE
WALLS GYP BD (;PAINT FLAT)
CEILING:: REMOVE GRID AND TILE, EXPOSED CONSTRUCITON
FLOOR REOMOVE EX, CARPET ADD NEW VCT
BASE: NEW RUBBER
WALLS: GYP BD (PAINT EE)
CEILING: EXISTING SUSPENDED ACOUSTIC
FLOOR: ` NEW SHEET VINYL (WELDEP SEAMS)
BASE: NEW S" COVED SWEET VINYL
WALLS: GYP BD (PAINT SCE)
WAIN5CT :NEW PLASTIC LAMINATE
CE LING: EX. GYP BD. (PAINT SCE)
irmur-williarill1111111P1111111
11111111111111111MTIMI ®P..ilrl%
iii _ 1 \i/
IMMIII PE !!!!I1111111iV
`�►r ■ row
•
NORTH
NO CHANGE TO WATTAGE, RELOCATE EXISTING LIGHTS
OR NEUJ NOT TO EXCEED THAT REMOVED
PROVIDE NEW, SWITCHING IN NEW ROANS
DOOR SCHEDULE (MATCH BUILDING STANDARD)
2,8
3,5
EX PAIR 3' X 1' ALUMINUM STOREFRONT WITH SAFTEY GLAZING,
CLOSER THRESHOLD, WEAHTERSTRIP, SIGN "THESE ODORS TO
REMAIN UNLOCKED DARING f3US1NES5 HOURS ".
EX 3'Xi' 8C VO0a POOR WITH METAL JAMB (PAINTED), 11/2 PAIR
BUTTS, LOCKSET, WALL STOP .AND SILENCERS
NEW OR RELOCATED 3'- 0 "XT-0" S.C. WOOD POOR WITH METAL
JAMBS (PAINTED), 1.0 PAIR BUTTS, LOCKSET, WALL STOP,
SILENCERS
EX DOOR (LIKE 2), ADD NEW 1/2 WINDOW SAFETY GLAZING IN
METAL FRAME (PAINTED)
NEW OR RELOCATED 3'- 0 "X1' -0" S.C. WOOD DOOR WITH METAL
6,1 JAMB (PAINTED), 11/2 PAIR BUTTS, LATCHSET, WALL STOP,
SILENCERS
10111 EXISTING ODOR (LIKE 2),- CHANGE TO LATGHSET EXISTING 3'X1'
SAC. WOOD DOOR WITH METAL JAMBS (PAINTED), I I/2 PAIR BUTTS,
HINGE CLOSER, WALL STOP, PRIVACY LOCK
12 EXISTING PAIR OF ALUMINUM STOREFRONT DOORS, SAFETY
GLAZING, NO CIAN EES
13
REACTIVATE EXISTING Ii'XI0' OVERHEAD DOOR, RESEAL JAMBS,
NEAR AND, SILL, ADD THERMAL INSULATION TO U =0.6
WINDOW SCNepl1L�
REFLECTED CEILING PLAN
SCALE 1/81 l'—a"
;..'1 REMOVE OR RELOCATE EX, LIGHT
Le f. J FI)<TtaRE 1X4
EXISTING FLOUORESNT LIGHTS
TO REMAIN
NEW OR RELOCATED
FLOURESCENT2X4
3/4 "x2"
FILLER SLACK
GASKETS 1/4"
EACH SIDE OF
FILLER
UJALL TO MULLION
SCALE; I -I/2" _
SILL f3E1.0W
DEEP LEG TRACK
ATTACH • SILL
AND CEILING -
DO NOT ATTACH
GYP, BD. TO
TRACK
STEEL STUD-
ATTACH GYP.
BD.
SECTION
RELITE: 2'- 0 "X6' -6" ON e" SILL, METAL JAMB TO MATCH POOR (PAINTED),
WITH 1/4" CLEAR SAFETY LAMINATED GLAZING.
WINDOW: REUSE EXISTING METAL FRAME (PAINTED) 4'X'4' ON 3' SILL, INSTALL
I/4" LAMINATED SAFETY GLANS.
IT -8 3/8"
511-6"
RE- ACTIVATE OVERHE D DOOR
REMOVE INTERIOR STU . WALL
EX
ELECT.
EX.
TELE
all
NEW BREAK
ROOM
NEU1 VCT
NELU CAB. WITH
SINK AND OW
C
OC
EX. ADA
Rill
0
EX. AD
Rte]
12
NEW
CLASSR001®
18'X30"
540 SF
1/1/20 :21 OCC.
NEW OFFICE]
101-111/4"
OFFICE FOR
COPIER AND
FILES
ADJ.
OFFICE
TENANT
Ex. QFFIcEIE
Ex. OFFICE
NEW RELITE
EX. OFFICEM
-NEW OFFICE®
in
SMOOTH HOLLOW METAL
JAMS (PAINTED)
CAULK BOTH SIDES
1 -' -51/8"
FLOOR PLAN: NEUJ: DUPONT
SCALE: 1 /8" - 1' -0"
NORTH 02 -16 -I2
ALL SPACES ARE HEATED AND COOLED
WALLS AND ROOF ARE INSULATED
REVIEWED FOR
CODE coMPUANCE
APPROVED
JUN 0 5 2012
City of Tukwila
BUILDING DIVISION
WOOD DOOR
HOLLOW METAL
DRY WALL FRAME
NEW WALL TO CEILING 0
RENTABLE SQUARE; FOOTAGE
TOTAL: 2,818 SF.
OCCUPANT LOAD:
OFFICE: 2,0145F 01002 21
CLASSROOM: 540 SF 6 1/20; 21
WAREHOUSE 264 SF 6 I/500: 1
TOTAL: 49 OCC.
SINGLE. EXIT I5 ALLOWABLE,
NO PATHWAY LIGHTING REQUIRED
FOR WALLS GREATER
THAN 8'- 0" IN
WIDTH WITHOUT AN
INTERSECTING: WALL,
PROVIDE 12Sa. WIRES
SPLAYED • 45 TO AN
EYE SCREW • ROOF
AND TOP OF WAL
�■■ ■ ■ ■■■■■■■■■■■ ■�� i■■■■■■■■■■■■
ATTACH TOP RUNNER
TRACK TO CEILING
GRIP WITH 2 -
X 1 "1/8" LONG
SCREWS AT 2' -0" O.C.
TYPICAL STUDS WALL PER SCHD.
(FOR WALL INSULATION SEE
PLAN) 5/8" GYP. 8D. EA,
SIDE (FLUSH FINISH).
MATCH BALANCE OF WALLS TO CEILING DETAIL
TYR UJSALL TO R. ELECTED CE IL INCA
SCALE: 1 -I/2 = 1'4=
5/8 GYP. BD.
BOTH SIDES
STEEL STUDS
O)
a') �°
cc) co
1 1
CO
^ C•
z
1<
ALL
0 F2
ce 0
=�
Zr
Ow
CO J
0) CA
SEE REFLECTED
CEILING PLAN
TYPICAL WALL
FRAMING
RECEIVED
MAY 212012
PERMIT CENTER
5/8" GYP. 8D.
ATTACH BOTTOM
TRACK TO CONC.
FLOOR W/ POWDER
DRIVEN ANCHORS, HILTI
OR APPROVED 1" EMBEDMENT
AT 24" D .C.
RUBBER
BASE w CARPET
ACOUSTICAL BLANKET
to SOUND WALL.
CONC. SLAB ON GRADE
CAULK GYP. BD. TO FLOOR
e ALL SOUND AND INSUL
WALLS
MATCH BALANCE OF DOOR JAMBS
IRIOR 1DOOR J
SCALE I -I/2" * l' -0"
SECTION
WALL TO SLA5
SECTION SCALE: 1 -1/2" : 1'4" SECTION
C:1Documents and SettingslAll UserslDocuments1CAD 11987 - 198918704- 81DUPONT 130281CD'S 05- 17- 121T- 1.DWG,<