Loading...
HomeMy WebLinkAboutPermit D12-171 - WESTFIELD SOUTHCENTER MALL - EXCALIBUR CUTLERY & GIFTS - CABINETS AND FLOORINGEXCALIBUR CUTLERY &GIFTS 211 S OUTH CENTER MALL D12 -171 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 211 SOUTHCENTER MALL TUKW Suite No: Project Name: EXCALIBUR CUTLERY & GIFTS Permit Number: D12-171 Issue Date: 06/13/2012 Permit Expires On: 12/10/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: JOHN JOST Address: 174 WALLIS ST , EUGENE OR 97402 Phone: 541 - 606 -0002 Contractor: Name: OWNER AFFIDAVIT ON FILE Phone: Address: Contractor License No: Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CABINETS AND FLOORING, OWNER INSTALLED Value of Construction: $32,000.00 Fees Collected: $1,141.27 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -171 Printed: 06 -13 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: 0643h;--- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I • •• authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IBC -7/10 D12 -171 Printed: 06 -13 -2012 7: VALIDITY OF PERMIT: The issuance or allaing of a permit shall not be construed to be gm rmit for, or an approval of, any violation of any of the provisions of the ding code or of any other ordinances of the ler of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -171 Printed: 06 -13 -2012 CITY OF TUKT4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Pete No. Project No. Date Application Accepted: tN- } -a.'-.' Date Application Expires: 1 \ -�y�— 7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION �A / / % King Co Assessor's Tax No.: a02-0.2-147 —00 I V Site Address: UV�S -f y�G c. Gc1/ s/(/�G' .f%N'i`c� Suite Number: C� ,3� Floor: / It-ty Tenant Name: EK Cc�.tt ✓w �V �S New Tenant: ❑ Yes .. No /) IA C // PROPERTY OWNER Name: -075 % � Address: n ct aj II S „`tt- e- Name: Ajel.. [[44' fj ~/ // f tN Address: Address:14a /k/ State:AA City- < i / u to ► i/61 State: Zip ( CONTACT PERSON - person receiving all project communication Name: -075 % � Address: n ct aj II S „`tt- e- City: Oj State: )R, Zip 7 lo -` t r `� Phone:s ,vC �(,-Ca7ZFax: EmaiLJ� 4,111 e4,-6,,,/, J 6,,,,,.,4 ,,,, .,O,,,r/ GENERAL CONTRACTOR INFORMATION Company Name: Company Name: C'f�-�. �_ /� / /, n ��19 CJi) oul Architect Name: Address: Engineer Name: Address:14a /k/ City: State: Zip: Phone: Fax: Email: 6ii v of t-.5 Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H: \Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh ARCHITECT OF RECORD Name: Company Name: C'f�-�. �_ /� / /, n ��19 CJi) oul Architect Name: Engineer Name: Address:14a /k/ /fiXonekdei & City:. V al4 C 0 00.4- State: ' , I'A Zip: CI VC Phone:360 67:7_ _ 53) : j j ‘74/(_78 4(r78 l,g Email: 6ii v of t-.5 Fax: g tA)141 0 gt 07 , u ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 32, 16-P9-e) Existing Building Valuation: $ Describe the sco a of work (please provide detailed information): tT /14 sc le, Will there be new rack storage? ❑ ....Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flamYnable, combustible or hazardous materials in the building? ❑ Yes ►i No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Sa 'ty data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor tO&S12 ; J • ,l 2 "d Floor 241 CSS 3rd Floor D tA ti t o D Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flamYnable, combustible or hazardous materials in the building? ❑ Yes ►i No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Sa 'ty data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: Mailing Address: it A T ORIZED AGENT: Date: "W44/2/1 l aca Day Telephone: SW q ,SX/ee.'6 CYQ, c?-76(6 ity State Zip H:Wpplications\Forms- Applications On Line12012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 4 of 4 PUBLIC WORKS PERMIT INFTION — 206 - 433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑...Valley View ❑...Renton ❑ ...Sewer Availability Provided 0... Renton ❑... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation 0... Geotechnical Report 0... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) O ... Right-of-way Use - Profit for less than 72 hours O ... Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage 0... Abandon Septic Tank ❑...Curb Cut 0... Pavement Cut 0... Looped Fire Line Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size If 0... Grease Interceptor 0... Channelization ❑ ... Trench Excavation 0... Utility Undergrounding WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # ❑ .. Deduct Water Meter Size " ❑ .. Sewer Main Extension Public ❑ Private ❑ ❑ .. Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer El.. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.Rov RECEIPT Parcel No.: 9202470010 Permit Number: D12-171 Address: 211 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/22/2012 Applicant: EXCALIBUR Issue Date: Receipt No.: R12 -01649 Payment Amount: $1,141.27 Initials: WER Payment Date: 05/22/2012 01:28 PM User ID: 1655 Balance: $0.00 Payee: JOHN JOST TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01936G ACCOUNT ITEM LIST: Description 1,141.27 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,141.27 688.95 447.82 4.50 doc: Receiot -06 Printed: 05 -22 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,_ #100, Tukwila. WA 98188 .Q (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: . EkCi L t t2 C t 1LL IZc c- Type of Inspection: TS T-/ Address: 0. l k 5 O Cy tti3 i nA f� t l Date Called: • Special Instructions: Date Wanted:. - Z7' l7.- ea'm� P:m Requester: Phone No: 1 I Approved per applicable codes. 0 Corrections required prior to approval. .. COMMENTS: 44 Tr; ;,-.),4? Date:/ _2 7. n REINSPECTION FEE EQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revis Project Info Project Address [4 e N4e.,... plow aGi Date p((.e.e_ 6 362 For Building Department Use FILE COPY No., '�. k Applicant Name: E kC.a t G/,_. ic,,ge .. e 41 / `GS Applicant Address: 17ci CuCr k ��'k€ G CW, Applicant Phone: 5c/ C 606 -02)2_ :rHt Project Description Eco/ Gt E.-Kew- MK_ New Building • Addition • Alteration U Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces dearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) not changed • No changes are being made to the lighting and space use ■ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. 4023 Maximum Allowed Lighting Wattage Location (floor plaNroom #) Occupancy Description Allowed Watts per ft2 ** cross mtenor Area in ft2 Allowed xArea '�. k k� /, 1-3 .5313S--- aria, ., � Eco/ Gt E.-Kew- MK_ 5 �b "i=8 .pc21s -1( ( ,zt ** From Table 15 -1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts / / /6. Sly' Proposed Lighting Wattage Location (flizor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed ii : , I --r-rzuele Atl ,CC0 ., � Eco/ Gt E.-Kew- MK_ 5 �b "i=8 .pc21s -1( ( ,zt / re 1, f- KO FL Al azac i 4023 3 S-" REVIEWED FOR COut euM LIANC —k APPRC QED JUN 132012 Total Propose. of p� City t fid BUIL br• ••. poi Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts L,,, I , escription, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. p iz -X71 RECEIVED MAY 22 2012 PERMIT CENTER zuus wasnington state tnergy code compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: CO Warehouse or Parking Garage • Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of f xtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. ' Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. . Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T-1, T 2, T-4, T-5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lilahtinst Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Pcwer Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft . 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, dothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling-mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the iquare footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. LPA` (Wlft` Use' LPA` (W /ftf) Automotive facility . 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 _ Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishment?, restaurants/barss 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail1°, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motionpicture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory° shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies _ 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Pcwer Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft . 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, dothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling-mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the iquare footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. P Professional Testing Laboratory, Inc. DATE: 05/09/2007 rkt,h c14/ CkuP4 T1 TEST REPORT FILE COPY TEST NUMBER: 107474 Philadelphia Carpet /Div. Of Shaw Industries ASTM E648 -03 Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using A Radiant Heat Energy Source, also referenced as NFPA 253 and FTM Standard 372 City of Tukwila GENERAL PRINCIPLE This procedure is designed to measure the critical radiant flux at flame out of QUIL136NGDMISION covering systems exposed to a flaming ignition in a test chamber which provides a graze: rd•ia"" ' =•" = �� environment. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames from a fully developed fire in an adjacent room or compartment. The test result is an average critical radiant flux (watts /square cm) which indicates the level of radiant heat energy required to sustain flame propagation in the flooring system once it has been ignited. A minimum of three test specimens are tested and the results are averaged. Theoretically, if a room fire does not impose a radiant flux that exceeds this critical level on a corridor floor covering system, flame spread will not occur. The NFPA Life Safety Code 101 specifies as Class 1 Critical Radiant Flux of .45 watts /sq cm or higher and (i,-,cc ') (�ritir rrl Rrirlir r,t Fh iY rrc 77 - dd �n,rttfc /crt rm FLOORING SYSTEM ASSEMBLY .. . . SUBSTRATE- D ESC R PTION OF TEST SAMPLE ryh .' IDENTIFICATION °.r Subset 1000 54410 Breaking News ___ . _ COLOR ,•,‘.4k , ,,',,. , 10100 REVIEWED FOR ROLL ' " , ` " .-. '_ E41378 -4 CODE COMPLIANC C' ON RUCTION ; 'te,Ir . ; "; Multi -Level Loop Pile APPROVED „FIBER ` JUN ,BACKING ��, �...,.,.._ .. , StaLok Pattern 1 3 2012 REFERENCES TEST NO: 043007 -8 ' City of Tukwila GENERAL PRINCIPLE This procedure is designed to measure the critical radiant flux at flame out of QUIL136NGDMISION covering systems exposed to a flaming ignition in a test chamber which provides a graze: rd•ia"" ' =•" = �� environment. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames from a fully developed fire in an adjacent room or compartment. The test result is an average critical radiant flux (watts /square cm) which indicates the level of radiant heat energy required to sustain flame propagation in the flooring system once it has been ignited. A minimum of three test specimens are tested and the results are averaged. Theoretically, if a room fire does not impose a radiant flux that exceeds this critical level on a corridor floor covering system, flame spread will not occur. The NFPA Life Safety Code 101 specifies as Class 1 Critical Radiant Flux of .45 watts /sq cm or higher and (i,-,cc ') (�ritir rrl Rrirlir r,t Fh iY rrc 77 - dd �n,rttfc /crt rm FLOORING SYSTEM ASSEMBLY .. . . SUBSTRATE- Mineral- Fiber /Cement Board UNDERLAYMENT Direct Glue Down ADHESIVE : Subset 1000 CONDITIONING ° . Minimum of 96 hours at 70 ± 5° F and 50 ± 5% relative humidity This test report relates to the installation in accordance with the criteria set forth in the report. Any variation in the installation criteria may produce different results. k'' Ayerage Critical Radiant Flux 0.53 Watts /Square Cm Standard Deviation 0.02 Watts /Square Cm Coefficient of Variation 2.86 * NOTE: Meets or exceeds Class 1 rating as specified in NFPA Life Safety Code 101 and IBC INCOMcitr' LTR# APPROVED BY: blZ ED JUN 06 2012 PERMIT CENTER 'This facility is acaediedbythe National iiohmaryLaboratcay Accreditation Pmgamforthe specific scope afacaedith t miler Lab Code 100297. This acaediatimdos not coast ite an endorsement. certification. or approvalby N]ST as arty agency ofthe United States Gov Govertmentforthe prodncttested. This report is providedforthe exclusive use of the client to winaa it is addressed. kni ybe used it its emaetyto gaalprodact accept. ce flan duly constituted aithcaides. This report apples onlyto those samples tested aid is not necessarily indvcati a of apparently identical of similar products. This report, crthe name of Professional Testing Laboratory Inc. shallratbe used under a y circumstance inadrertisingtothe generalpublic. Distance Burned TimejO,FlamevOuti . , w.. :ra, ,Critical. Radiant.Flu/44 Specimen 1 37 cm 43 minutes 0.53 watts /square cm Specimen 2 38 cm 21 minutes 0.52 watts /square cm Specimen 3 36 cm. 26 minutes 0.55 watts /square cm k'' Ayerage Critical Radiant Flux 0.53 Watts /Square Cm Standard Deviation 0.02 Watts /Square Cm Coefficient of Variation 2.86 * NOTE: Meets or exceeds Class 1 rating as specified in NFPA Life Safety Code 101 and IBC INCOMcitr' LTR# APPROVED BY: blZ ED JUN 06 2012 PERMIT CENTER 'This facility is acaediedbythe National iiohmaryLaboratcay Accreditation Pmgamforthe specific scope afacaedith t miler Lab Code 100297. This acaediatimdos not coast ite an endorsement. certification. or approvalby N]ST as arty agency ofthe United States Gov Govertmentforthe prodncttested. This report is providedforthe exclusive use of the client to winaa it is addressed. kni ybe used it its emaetyto gaalprodact accept. ce flan duly constituted aithcaides. This report apples onlyto those samples tested aid is not necessarily indvcati a of apparently identical of similar products. This report, crthe name of Professional Testing Laboratory Inc. shallratbe used under a y circumstance inadrertisingtothe generalpublic. j fat wcu%I MDF medium density fiberboard Features & Benefits • Awarded CARB ULEF Exemption, Products meet CARB ATCM 93120 Phase 2 emission requirements • Meets physical properties of ANSI A208.2 -2009 Grade 130 • FSC® certified panels available upon request Mill Capabilities • Panels available in 4' and 5' widths Panels available in lengths up to 18' • Minimum order may be required for some sizes How to Specify Specify Medite® or. Medite® 3D, industrial grade: medium; density fiberboard (MDF) andlmg & Installation Store' indoors on a' flat; :level :surface with• 'odequate support to. o "prevent sagging .. rt Refer to Architectural:.Woodwork: •Standards AWS) forfabricatiori" acid• installation procedures.': i Medite ®& Medie ®. 3D' are'riot suitable for'use :, • in external Or,':'strUcturat applications or in areas;; where moisture- is':a -concern .; For best results condition .to the environme 48 -72 hours prior to installation I Because of, -.its unparalleled hard, smooth surfacer Medite® 'easily accepts. many. finishes{ including:. paint, varnish, lacquer; UV- fills, laminates and foils Panels are available- in thicknesses ranging from 1/4" 1-1/2". Strength and machinability make Medite® the right choice for fabrication and precision parts: Fu,niture Cabinets d�dt f Stereo;Speakers Door ,Parts Store. Fixtures Toys & Musical Instruments, med ite 3D Engineered'; for demanding three dimensional`. aoolications— PaoeIS are_available -in_ thicknesses_ med fte medfter 3D SierraPine Medite® and Medite® 3D brands produced in Medfon manufactured from pre - consumer recycled wood content. These pr engineered for a wide range of applications. For decades the Meditet been recognized globally for quality and consistency in MDF. Medite® a 3D are widely distributed throughout North America. Technical Data Medite® Meditr Density Internal Bond Modulus of Rupture Modulus of Elasticity Modulus of Hardness Screw Holding, Face Screw Holding, Edge Thickness Tolerance Flame Spread Rating Moisture Content Thickness Swell Linear Expansion 46 lb /ft3 1301b /in2 4,000 lb /in2 450,000 lb/in2 950 lbs Janka ball 225 lbs 200 lbs ±0.005 inch Class 3 (C) 4 -6% 5% 0.3% 48 lb/f 140 lb/ 4,000 450,00 900 lb: 300 lb. 280 lb: +0.00! Class : 4 - 6% 5% 0.3% Average physical properties for 3/4" panel, based on a 5 panel average, when tested in accordance with ASTM DIC in accordance with ASTM E -1333. Specific design applications, and technical data are available upon request ,sob FSC FSC 0014047 i MIMED Minimum 00% Racycled Content FSC® 0014647 The mark of responsible forestry (Available upon request) ,t.SE OFk 1�": �'.4,��, ECC Certified f p Specification CPA ECI ECCI`E i CARB Third Party C.a SCS Certified SCS -MC -01584 Pre - Consumer Recycled Wood Content LEED® 2009 Credit Materials & Resourcf SierraPine warrants that its products will meet the specifications applicable to such products in effect at the • disdosed to customer and available on SierraPine's website at www.sierrapine.com under Terms & Canditi breach of such warranty must be received by SierroPine within 90 days after delivery of products to custome no other warranty or guarantee, either expressed or implied, including implied warranties of merchantability particular purpose to the original purchaser or to any subsequent user of the products, except as expressly car & Conditions. In the event state or provincial law precludes exclusion or limitation of implied warranties, the c b coRATIVE SU.RP. FIRE RATING INFORMATION GENERAL PURPOSE LAMINATES Nevamar General Purpose Laminates Fire Rating Information Testing Service: _ Hardwood Plywood & Veneer Association Test Method: ASTM E 84 Twenty Five Foot Tunnel Furnace • Grade Flame Spread Index Smoke Developed Index Test Record Nevamar® HGS, Horizontal general purpose Unbonded (no substrate) 60 105 T -1 1 154 Nevamar® HGP Horizontal postforming Unbonded (no substrate) 35 40 T -13483 Nevamar® VGP Vertical postforming Unbonded (no substrate) 40 70 T -1 1 153 The test results indicate the above products meet the requirements for a Class B fire rating. May eJ 1e 1e: b- /p soJii r(oovi\id 1r pProfessional Testing Lobreratory, lnC. DATE 03/052012 7 TEST REPORT • TEST NUMBER: 145514 ASTM E648-08 Standard Test. Method for Critical Radiant Flux of. Boor Covering Systems Using Radiant Heat Energy Source, olso referenced as NFPA 253 and TM Standard 372 41 a `Ji, Sri,? Jar?; ySul,ir?isa;,u HDF Strand Woven 6 Bamboo � rith Attach Cg rgA AT This procedure graded radiant heat energy This procedure Is designed to measure the critical rodcxtt flux flame out 9 horizontally mounted floor covering systems exposed too flaming ignition In a test chamber vets des to impinge on the floors r a whose upper surfaces ore heated by flames from a tufty d rveloped fire in an adjacent room or environment. The Imposed radiant flux simulates the thermal radiation which Indicates the level of building compartment. The test result is on average critical radiant flux fle Hoof g system once it has been ignited. A radiant heat energy test specid n sore t ted a d propagation re tam, flame spread fire not occur. minimum of three test specimens ore t�erstCadi level the o o corridor floor coy :ring Theoretically, it o room fire does not impose a radiant flux that exceeds this The NFPA Life Safety Code 101 specifies os Class I Critical Racrir nt Flux of .45 watts /sq cm or higher and Class 2 Critical Radiant Flux os .22' .44 watts s• cm. Loa ° aid Mini rela ive humidi numot96 hours ot70t5°Fond50t5% Specimen 1 specimen 2 Specimen 3 4 minute minute 51 minute 0.27 watts /square cm 0,24 watts /square cm 025 Watts/Square Cn 0.01 Watts / square Cr .92 % s NOTE: Meets or exceeds Class 2 rating as specified in NFPA Life Safety Code 101 and IBC 804.2 Classification. APPROVED 8Y: ciA I- ads ne m?�sedaeateabyea!xeiaesltleoloa Labargmykaeas dtPlo�ak strgedars rf ITed order Lai6m'WO3P7.4ds maiden dm notcaeetese onendeerementaatiscalortmieprearaltVISTarastragincyotthc Uctke43tetes Doman Mille product tened.This kpemfdedindtt ccelOSicre use of tbe diet Is than It k teltKRd. Lally 6! aced h Is eelfrecrto gelapcoaut eecept mce Iwo ) oresdened elfhorkles. 'IIelreipat sjaplbs eelyse arose mphe tested and k roCssecessrafly cfdSeabe d appwently iera nal dsrteiln pedals. s. lbtr i. albs mace der toisdiocel ttitttngLebaaay be. *al =be %6d %Eder rig elnnaacta+ti in tdrattstrgeo 4e da+mtlpehic. 714 Glenwood Place Daiwa, GA 30721 Phone :73.225-3223 F c: 705-z26.67V mwl: poiellecestainksts Received Time May, 29. 2:40PM Lt SPECIFICATION DATA Style Name: BELLA VITA 12UNI Style Number: 54170 Description: NEEDLEBOND Fiber Content: 100% HI UV STABILIZED OLEFIN Face Weight: . 14.0 ozs /yd2 Pattern: DILOUR Pile Height: 0.118 in Total Thickness::.. 0.226 in Face Coat: Primary Backing: Secondary Backing: Total Weight: Density: Width: Rolled: Number of Colors: Dye Method: Coefficient of Friction: Applications: N/A UNITARY 18 ozs /yd2 4710 12ft Face In 2 SOLUTION DYED 0.71 Pattern Repeat: NONE Star Rating: 3 Special Features: PRODUCT DATA Flammability: Pill Test (CPSC FF1 -70): Tunnel Test (ASTM -E84): Corner Burn Test (UBC -82): Automotive Flammability (FMVSS -302): Acoustic: Noise Reduction Coefficient : NRC Gypsum: Accoustical Backer: Warranties: 2 YEAR INDOOR/OUTDOOR FADE 5/3 YR LIMITED INDOOR/OUTDOOR QA CRI Certification: Durability Rating: PASS Except where noted as a minimum or maximun, the above specifications are nominal and, therefore, are subject to change and to normal manufacturing variance. 5 1VJi JJ PDF Copy 11LL11./ / W VV W.as+LI VL.111J.L.U11L V lLi YY_1YI0LJ/ 11ULL1U1,,,FIUJ_ V Tvc/ 1ILflJ 3... PRINT BEHRer STAINS•VARNISHES• PA View (M)SDS Section : 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION Product Name: Product Code: MSDS Manufacturer Number: Manufacturer Name: Address: General Phone Number: General Fax Number: Customer Service Phone Number: CHEMTREC: Canutec: MSDS Creation Date: MSDS Revision Date: MSDS Format: PREMIUM PLUS ULTRA® Interior Eggshell Enamel Medium Base No. 2754 2754 2754 BEHR Process Corporation 3400 W. Segerstrom Avenue Santa Ana, CA 92704 (714) 545-7101 (714) 241 -1002 (800) 854 -0133 ext. 2 For emergencies in the US, call CHEMTREC: 800 - 424 -9300 In Canada, call CANUTEC: (613) 996 -6666 (call collect) January 30, 2007 March 31, 2012 According to ANSI Z400.1 -2004 NFPA 1 1 0 HMIS Health Hazard 1 Fire Hazard 1 Reactivity 0 Personal Protection * Chronic Health Effects SECTION 2 - COMPOSITION /INFORMATION ON INGREDIENTS Chemical Name CAS# Ingredient Percent 2- ethylhexyl benzoate Nepheline Syenite Water Styrene /acrylic copolymer Anhydrous aluminum silicate Titanium dioxide Acrylic polymer(s) P(BA/MMA) 5444 -75 -7 37244 -96 -5 7732 -18 -5 No data 66402 -68 -4 13463 -67 -7 No data 25852 -37 -3 1 - 5 by weight 5 - 10 by weight 30 - 60 by weight 1 - 5 by weight 1 - 5 by weight 10 - 30 by weight 10 - 30 by weight 5 - 10 by weight SECTION 3 - HAZARDS IDENTIFICATION Emergency Overview: Potential Health Effects: Eye: Skin: Inhalation: Irritant. May cause irritation. May cause irritation. Prolonged or excessive inhalation may cause respiratory tract irritation. 6 1 of 5 6/4/2012 12:01 PM 1V1JLJ IlLL1/.l I VV VV VV .LLI.L1Vld1,O.VV11Y • ... .,,...,.,p.. »� • • •• ... .... .. ...... Ingestion: May be harmful if swallowed. May cause vomiting. Chronic Health Effects: Prolonged or repeated contact may cause skin irritation. Signs /Symptoms: Overexposure may cause headaches and dizziness. Target Organs: Eyes. Skin. Respiratory system. Digestive system. Aggravation of Pre - Existing None generally recognized. Conditions: SECTION 4 - FIRST AID MEASURES Eye Contact: Skin Contact: Inhalation: Ingestion: Other First Aid: Immediately flush eyes with plenty of water for 15 to 20 minutes. Get medical attention, if irritation or symptoms of overexposure persists. Immediately wash skin with soap and plenty of water. Get medical attention if irritation develops or persists. If inhaled, remove to fresh air. If not breathing, give artificial respiration or give oxygen by trained personnel. Seek immediate medical attention. If swallowed, do NOT induce vomiting. Call a physician or poison control center immediately. Never give anything by mouth to an unconscious person. Due to possible aspiration into the lungs, DO NOT induce vomiting if ingested. Provide a glass of water to dilute the material in the stomach. If vomiting occurs naturally, have the person lean forward to reduce the risk of aspiration. SECTION 5 - FIRE FIGHTING MEASURES Flash Point: No Data Lower Flammable /Explosive Limit: Not applicable. Upper Flammable /Explosive Limit: Not applicable. Extinguishing Media: Use alcohol resistant foam, carbon dioxide, dry chemical, or water fog or spray when fighting fires involving this material. Protective Equipment: As in any fire, wear Self- Contained Breathing Apparatus (SCBA), MSHA/NIOSH (approved or equivalent) and full protective gear. NFPA Ratings: NFPA Health: NFPA Flammability: NFPA Reactivity: 1 1 0 SECTION 6 - ACCIDENTAL RELEASE MEASURES Personnel Precautions: Use proper personal protective equipment as listed in section 8. Environmental Precautions: Avoid runoff into storm sewers, ditches, and waterways. Spill Cleanup Measures: Absorb spill with inert material (e.g., dry sand or earth), then place in a chemical waste container. Provide ventilation. Clean up spills immediately observing precautions in the protective equipment section. SECTION 7 - HANDLING and STORAGE Handling: Use with adequate ventilation. Avoid breathing vapor and contact with eyes, skin and clothing. 7 2 of 5 6/4/2012 12:01 PM MSU Storage: 1111). // W W W.QVl1Vl,111J ..,V111/ V Ili YY 1V1UL J /lluunra ✓a oFmj_ • -rvc -, Store in a cool, dry, well ventilated area away from sources of heat, combustible materials, and incompatible substances. Keep container tightly closed when not in use. Hygiene Practices: Wash thoroughly after handling. Avoid contact with eyes and skin. Avoid inhaling vapor or mist. SECTION 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION - EXPOSURE GUIDELINES Engineering Controls: Eye /Face Protection: Use appropriate engineering control such as process enclosures, local exhaust. ventilation, or other engineenng controls to control airborne levels below,. recommended exposure limits. Good general ventilation should be sufficient to control airborne levels. Where such systems are not effective wear suitable personal protective equipment, which performs satisfactorily and meets OSHA or other recognized standards. Consult with local procedures for selection, training, inspection and maintenance of the personal protective equipment. Wear appropriate protective glasses or splash goggles as described by 29 CFR 1910.133, OSHA eye and face protection regulation, or the European standard EN 166. Skin Protection Descnption: Chemical- resistant gloves and chemical goggles, face - shield and synthetic apron or coveralls should be used to prevent contact with eyes, skin or clothing. Wear appropriate protective gloves. Consult glove manufacturer's data for permeability data. Respiratory Protection: A NIOSH approved air - purifying respirator with an organic vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed exposure limits. Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator if there is any potential for an uncontrolled release, exposure levels are not known, or any other circumstances where air purifying respirators may not provide adequate protection. Other Protective: Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. EXPOSURE GUIDELINES Titanium dioxide : Guideline ACGIH: Guideline OSHA: TLV -TWA: 10 mg /m3 OSHA -TWA: 15 mg /m3 SECTION 9 - PHYSICAL and CHEMICAL PROPERTIES Physical State Appearance: Liquid. Color: White Boiling Point: No Data Melting Point: No Data Density: 10 - 12 Lbs. /gal. Vapor Density: Greater than 1 (Air = 1). Vapor Pressure: Greater than 1 (Air = 1). pH: 8.5 to 9.5 Molecular Formula: Mixture Molecular Weight: Mixture Flash Point: No Data VOC Content: Material VOC: 20 gm /I (Includes Water) Coating VOC.: 47 gm /I (Excludes Water) The addition of colorant may add VOCs. SECTION 10 - STABILITY and REACTIVITY 3 of 5 6/4/2012 12:01 PM MSUS IILLI./. // W W W.0.Li L1V1+111J.liVaaL v1L VV j_. .... -.. ....+...�... Chemical Stability: Stable under normal temperatures and pressures. Hazardous Polymerization: Not reported. Conditions to Avoid: Heat, flames, incompatible materials, and freezing or temperatures below 32 deg. F. Incompatible Materials: Oxidizing agents. Strong acids and alkalis. Special Decomposition Products: Incomplete combustion may produce carbon monoxide and other toxic gases. SECTION 11 - TOXICOLOGICAL INFORMATION Neaheline Svenite : RTECS Number: Titanium dioxide : RTECS Number: Skin: Carcinogenicity: p(BA /MMA) : RTECS Number: QP9365000 XR2275000 Administration onto the skin - Human Standard Draize test.: 300 ug /3D (Intermittent) (RTECS) 13463 -67 -7 UD3428000 SECTION 12 - ECOLOGICAL INFORMATION Ecotoxicity: Environmental Fate: No ecotoxicity data was found for the product. No environmental information found for this product. SECTION 13 - DISPOSAL CONSIDERATIONS Waste Disposal: Consult with the US EPA Guidelines listed in 40 CFR Part 261.3 for the classifications of hazardous waste prior to disposal. Furthermore, consult with your state and local waste requirements or guidelines, if applicable, to ensure compliance. Arrange disposal in accordance to the EPA and /or state and local guidelines. SECTION 14 - TRANSPORT INFORMATION DOT UN Number: DOT Hazard Class: No Data No Data SECTION 15 - REGULATORY INFORMATION California PROP 65: WARNING: This product contains a chemical known to the state of California to cause cancer and birth defects or other reproductive harm. 2- ethvlhexvl benzoate : TSCA Inventory Status: Listed Canada DSL: Listed JVeoheline Svenite : TSCA Inventory Status: Not listed 4 of 5 6/4/2012 12:01 PM 1V1JUJ Canada DSL: Anhydrous aluminum silicate : TSCA Inventory Status: Canada DSL: Titanium dioxide : TSCA Inventory Status: State Regulations: 11LLIJ . //w W W.CjI+ L1VL.11LJ.L.V11L V .It. Y♦1•11)LL)/ ALLLl1V1✓ioFiuj ♦ —rvci u... �+.s... Listed Listed Listed Listed Listed in the New Jersey State Right to Know List. Listed in the Pennsylvania State Hazardous Substances List. Canada DSL: Listed P(BA /MMA) : TSCA Inventory Status: Listed Canada DSL: Listed SECTION 16 - ADDITIONAL INFORMATION HMIS Health Hazard: 1 HMIS Fire Hazard: 1 HMIS Reactivity: 0 HMIS Other: x MSDS Creation Date: January 30, 2007 MSDS Revision Date: March 31, 2012 MSDS Revision Notes: Quarterly formula update MSDS Author: Actio Corporation Disclaimer: This Health and Safety Information is correct to the best of our knowledge and belief at the date of its publication but we cannot accept liability for any loss, injury or damage which may result from its use. We shall ensure, so far as is reasonably practicable, that any revision of this Data Sheet is sent to all customers to whom we have directly supplied this substance, but must point out that it is the responsibility of any intermediate supplier to ensure that such revision is passed to the ultimate user. The information given in the Data Sheet is designed only as a guidance for safe handling, storage and the use of the substance. It is not a specification nor does it guarantee any specific properties. All chemicals should be handled only by competent personnel, within a controlled environment. Should further information be required, this can be obtained through the sales office whose address is at the top of this data sheet. Trademark: The trademarks, service marks, graphics and logos used on this MSDS are registered or unregistered trademarks of BEHR Process Corporation. All Rights Reserved. Copyright© 1996 -2011 Actio Corporation. All Rights Reserved. Co 5 of 5 6/4/2012 12:01 PM 06/01/2012 11:12 FAX s4ektiv-N Chemcraft Product Code. 825 -8000 Clear Base 825 -8001 Black 825 -8002 Burnt Sienna 825 -8003 Burnt Umber 825 -8004 Dark Umber 825 -8005 Red 825 -8006 Raw Sienna 825 -8007 Raw Umber 8258008 Van Dyke 825 -8009 White PromatchTM C -Mix Base & Monocolors 825 -80)EX VISCOSITY _:.... . FLASH PC INT; DENSITY I lb /gal): SOLID (% by weight): SOLID (% by volume): SHELF L1 E (months): .N /A ..__ ., 80 °F (,7 °) 7.5 — 8.3 9 - 30% 6 - 24% 12 Product Description: PromatchTM C -mix 8000 Stains (825 -80XX) are all .purpose wipe stains for furniture and cabinets, They should be mixed well due to the heavy concentration of pigments. Applic: don may be by hand or spray. Stains are intermixable and /or reducible. PromatchTM C -mix 8000 stains (825 -80XX) offer a simple o ie step stain color base, good clarity and grain fill with ease of workability. Uses; Environmental Data (as supplied): VOC less exempt lb /gal: VOC lb /gal: VOC less exempt g /1: VOC g /I: VOC lb /lb Solid: VHAPs lb /lb Solid: 5.41— 6.85 5.3 1— 6.70 65( - 825 63: - 800 2.2. — 10.2 0.2 — 1.05 Application Data: SUGGESTED USES: MIXING RATIO: POT LIFE: APPLICATION VISCOSITY: REDUCER: RETARDER: CLEAN -UP SOLVENT: APPLIED FILM THICKNESS: DYE ACCEPTANCE: Woad Finish N/A N/A N// 825.8000 800 -4310 802.0020 N// Use 803 -1307 Solvent for Dyes stain. 10% by volume Jo-0c AkioNobe 00694_051108 06/01/2012 11:12 FAX Directions for Use l 005/005 PromatchTM C -Mix Base & Monocolors 825 -80XX Surface Preparation: Wood substrate should be sanded with 120, 150 0. 180 grit paper prior to staining or coating. On woods such as maple, coarser sanding, such as 150 grit, should be performed to a /old polishing of the wood surface. Hand sanding in the direction of the grain following orbital sanding will remove swirl marks. General Information: Application may be by hand or spray. These staff: clean rag to ensure good adhesion by subsequent clear coats. If the stain i Stain Base (825- 8000). These products may be clear coated with any of the following systems: P Danspeede Elite (424- 44XX), Opticlear 900 (431- 80XX), Chemlack (441 All 825 -80XX stains are acid stable, They will not change color when an them. Is must be wiped into the grain and wiped clean with a too dark, the color strength may be reduced using Intermix asticlear (421- 40XX), Plastofix® Light (421- 48XX). •SOXX) as well as the sealers associated with these systems. acid cured Chemcraft product is used to seal and topcoat These stains demonstrate good open time to allow for uniform appearance t n large pieces. Product must be thoroughly agitated before use. THE CUSTOMER IS RESPONSIBLE FOR FOLLOWING THE RECO.AMENDED APPLICATION PROCEDURES. FAILURE TO ADHERE TO THE RECOMMENDATIONS GIVEN INTHIS DATA SHEET WILL LIKELY RESULT IN UNSATISFACTORY FILM APPEARANCE OR FILM FAILURE. THIl COMPLETE COATING SYSTEM SHOULD BE CHECKED FOR REQUIRED PROPERTIES PRIOR TO THE START- JP OF PRODUCTION. Drying Times: Tack Free Time: Dry to Sand: Dry to Stack: At 68 °F 1 hour N/A N/A At 22 °F 30. 40 mins. N/A N/A Note: pry times are greatly affected by film build, porosity of substrate, air : novement as well as heat and humidity. Temperatures are based on actual board temperature. This may vary depending on length of i ime for boards to reach these temperatures_ Minimum curing temperatures of 64 °F /18 °C must be maintained throughout the curing; cycle to achieve the film integrity as stated in product features. These products are designed for industrial use only. AkzoNobel views safes y as a top priority. Please refer to Material Safety Data Sheet for information on the safe use of this product. Values shown arc calculated estimates and should not be construed as product specifications Our products or the products of other manufacturers in combination with our products may Ix application of this information or the surely and suitability of each such product or product cr we sell the products without warranty, and users assume all responsibility and liability For los. combination with other products. IIso of unapproved or reclaimed solvent blends may redtle Akzo Nobel Coatings, Inc_ 1431 Progress Ave High Point, NC 27261 336- 841 -5111 We cannot anticipate all conditions under which this information and used. We accept no responsibility for results obtained by the mbmation for their own purposes Unless otherwise agreed in wnting, or damage arising from the use of our products whether used alone or a lihn properties and is not recommended. Revised l0 /09T CHARACTERI STICS Gloss (measured on bim:k glass): Gloss 85+ unit; BRE 55 -59 w its MRE 30 -34 a its DRE 17 -21 w uts Volume Solids: 25 ± 2% Weight Solids: 33 ± 2% Viscosity: 25-30 seconds #2 Zahn Cup Recommended film thici ness: Mils Wet 3.0 - 5.0 Mils Dry 0.75 - 1. ?5 Maximum dry film thickne ss of the total system should not exceed 4,0 mils Spreading Rate (no applk ation loss) 295 -577 sq ft/gal ( 0,75 -'.25 mil DFT Drying (77 °F, 50% RH): To Touch: 10 - 15 r tinutes To Handle; 15 - 20 r iinutes To Sand: 30 - 45 r ilnutes To Recoat/Topcoat: 30 - 45 minutes To Pack: 8 hour rr inimum Force Dry: 5 - 10 m lutes at 110 - 140°F, ti en air dry 1 hour mir mum to pack Flash Point: 4 °F Pen: .ky- Martens Closed ( up Mixing Ratio: 1 gallon Lacquer 3.0 ounces Catalyst /66V3 Pot Life: 4 month: Package Life: Uncatelyzed 2 years, inopened Catalyzed 4 month: Alr Quality Data: (Theoret cal) • Non- photochemically rep ctive • Volatile Organic Compoi nds (VOC) as packaged, maximum 5.42 lb /gal, 649 g /L, 2.38 lbs VOC /Ib solids • Hazardous Air Pollutant: (HAPS) as packaged, No Report able HAPS An Environmental Data She at is available from your local Sherwin -Willi tms facility. 06/01/2012 11:11 FAX SHERWIN WILLIAMS. Z 002/005 13 Product Finishes CC -F57 ,(1 Cia'an3HER-WOOD® Hi -Btld PreCat Lacquer DESCRIPTION Sher -Wood® HI -Blld PreCat Lacquer is a fast drying, high performance, dear, conversion lacquer designed for the Kitchen and Bath Cabinetry and General Wood Finishing markets. After catalyze - Von it provides a 4 month pot life, Advantages: • 20% higher volume solids than tradi- tional PreCet lacquers, • Meets (KCMA) specifications as a self sealed system or over catalyzed Sher -Wood Vinyl Sealers, T67F3, T67F5 or T67F6. • HAPS Free as packaged, • Fast dry to sanding and packing. • Contains UV absorber to significantly reduce the discoloration of natural wood from exposure to sunlight. • Good resistance to household chemi- cals. • Good flexibility — passes 20 KCMA cold check cycles. • Versatile application — may be applied by conventional, airless, air- assisted airless spray. • Pale water white color. • Ideal for kitchen cabinets, vanities, chairs, office furniture, household furniture • Free of lead hazards as packaged in compliance with Consumer Product Safety Commission's (CPSC) 16 CFR Chapter II: Subchapter 8, Part 1303. CC -F57 Gloss T77C55 Bright Rubbed Effect T77F56 Medium Rubbed Effect T77F57 Dull Rubbed Effect T77F58 Catalyst V66V3 06/11 SPECIFICATIONS Wood (interior only): Must be clean, dry, and finish sanded. Substrate should be free of grease, oil, dirt, fingerprints, and any contamination to ensure optimum adhesion and coating performance prop- erties. Moisture content of wood should be 6 to 8 %. Wood Finishing System; THIS PRODUCT MUST BE CATALYZED. 1. Color Wood - Stain or tone as desired and dry thoroughly. 2. Seal - Apply Sher -Wood Hi -Gild Pre - Cat Lacquer as a sealer or sear with catalyzed Sher -Wood Vinyl Sealers, T67F3, T67F5 or T67F6. (Consult corre- sponding data page for details). Spray a full wet coat. Air Dry 30 - 45 minutes, 3. Sand - Sand with 240 grit or equiva- lent. Remove sanding dust. 4. Topcoat - Spray a full wet coat of Sher -Wood Hi -Bild PreCat Lacquer at 3,0 - 5.0 mils wet, 5. For more depth or build, apply an addi- tional coat. Do not exceed 4.0 mils DFT for the total system, Testing: Due to the wide variety of sub- strates, surface preparation methods, application methods, and environments, the customer should test the complete system for adhesion, compatibility and performance prior to full scale applica- tion, continued on back SPECIFICATIOt IS Product Limitations: • This product must be cab lyzed with Sher -Wood HI -Blld PreCa Catalyst, VeSV3, before use at a ler al of 2,3% (3.0 oz/gal). Complete, cross. linking and film properties will not be at tined with- out CatalyzatIon. Product will :yplcally be catalyzed before delivery ti : the cus- tomer. • Catalyst must be added by he user or by the Sherwin- Williams outle . • This product should be use 1 within 4 months after being catalyzed to obtain optimum properties. The cata yst causes a chemical reaction In the pi ckage and dissipates after 4 months ar d perform- ance properties are downgn dad, Add- ing additional catalyst do s not re- store film propertioe. • Store at room temperature (u Eder 80° F) after catalyzation, Higher to nperatures will reduce the storage life, - Self -seal or apply over Sher -1 Vood Vinyl Sealers, T67F3, T67F5 or T67F6 to meet KCMA requirements. • To achieve maximum perform ante prop- erties a minimum of 2 mils )FT is re- quired. • Total film thickness of system must not exceed 4 mils DFT becau..e heavier films may show cracking an I checking tendencies. • For interior use only. • Sher -Wood Hi -Slid PreCat Catalyst, V66V3 is an acid. To prevent acid corro- sion and pitting, all equipmen should be made of stainless steel. 3ontainers Should be stainless steel or pl, istic. • Do not catalyze with other ac 9 catalysts because of fast reactivity aid pot life issues. • Maximum cure and chemical resistance is attained after 10 days air dr ping, Natural wood will change col )r by itself and clear wood finishes will nt t keep this from occurring. • To maintain HAPS compli; nce, only reduce with HAPS compliant r aducers, • Sher -Wood Hi -Slid PreCat L icquer will yellow over time. With wood 1 me stains, this yellowing actually makes a warmer, softer appearance, Where w lite stains, pickled finishes, or white bas coats are used, nitrocellulose lacquer should not be used because of the yello' ping of the sealer and topcoat may be ;onsldered objectionable. For these a iplications, Sher -Wood Acrylic Conversli •n Coating is recommended, 0E7'01/2012 11:11 FAX APPLICATION Typical Setups THIS PRODUCT MUST BE CATALYZED DETERMINE IF IT HAS BEEN CATA- LYZED, If not catalyzed, add 2.3% (3.0 oz/gal) Sher -Wood Hi -Bild PreCat Cata- Iyst,,V88V3., Potllfe after catalyzation Is 4 months. Record the catalyzation date on the container. ' Reduction: Product Is normally applied without reduction. If reduction is needed to optimize application, use 5 - 10% HAPS Compliant Lacquer Thinner, R7K320. R7K305 or Acetone. Lacquer Thinner K120 or K22 may also be used, but are not HAPS compliant. Product can be re- tarded with MAK, EEP or Butyl Cellosolve. Conventional Spray: Air Pressure 35 - 60 psi Fluid Pressure 6 -10 psi Cap /Tip 797 Airless Spray: Pressure 1500 - 1800 psi Tip .011 - .013" Air Assisted Airless: Alr Pressure 20 - 30 psi Fluld Pressure 500 - 900 psi Cap/Tip .011 - .013 HVLP: Gun Blnks Mach 1 Atomizing Air Pressure at the cap 9 psi Fluid Pressure ,., 12 pal Cap/Tip 97AP Blue Max /94 Cleanup: Clean tools /equipment immediately after use with HAPS complying Lacquer Thin- ner, R7K320 . Lacquer Thinner K120 or K22 may also be used, but ere not HAPS compliant Follow manufacturer's safety recommen- dations when using any solvent. Performance Tests: Household Chemicals Test Using ANSI -KCMA A161,2000 test proce- dures, panels were Cured by air drying and allowed to age 10 days et ambient conditions before testing. Tests were conducted on self - sealed (2 coat) finished panels at 2.0 mils total DFT. Materials were washed off with clear water after 24 hours and allowed to reoover for 10 days then the Finish was ex- amined and the following results noted: Vinegar no effect Lemon Juice no effect Orange Juice ..................... no effect Grape Juice no effect Tomato Catsup no effect Coffee ® 115° F no effect Olive 011. no effect 100 Proof Alcohol no effect Water & Detergent . .. „ ,..,no effect Mustard no effect Cold Checks 20 cycles Pass Edge Soak Pass lj 003/005 CC -F57 Sher -Wood® Hi -Bild PreCat Lacquer CAUTIONS FOR INDUSTRIAL SHOP APPLICATION Thoroughly review product label and Material Safety Data Sheet (MSDS) for safety and cautions prior to using this , product. A Material Safety Data Sheet is avail- able from your local Sherwin - Williams facility. Please direct any questions or com- ments to your local Sherwin - Williams facility. Note: Product Data Sheets are periodi- cally updated to reflect new information relating to the product. It is important that the customer obtain the most recent Prod- uct Data Sheet for the product being used. The Information, rating, and opinions stated here pertain to the material cur- rently offered and represent the results of tests believed to be reliable. However, due to variations in customer handling and methods of application which are not known or under our control, The Sherwin - Williams Company cannot make any war- ranties as to the end result. • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1908 May 24, 2012 John Jost 174 Wallis St Eugene, OR 97402 RE: Incomplete Letter #1 Development Permit Application D12 -171 Excalibur Cutlery & Gifts — 211 Southcenter Mall Dear Mr. Jost, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on May 22, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, /:>X qdt.‘. Bill Rambo Permit Technician Enclosures File: D12 -171 W.'\Permit Center \Incomplete Letters \20I2 \D12 -171 Incomplete Ltr # 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: May 24, 2012 Project Name: Excalibur Cutlery & Gifts Permit #: D12 -171 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide manufacturer's specifications for the cabinetry and carpet covering and flooring that show materials used meet code for Type II construction as specified in SECTION 603 of 2009 IBC. Included a cover plan sheet with notes that clearly specifies the scope of work with all other relevant code information, type of construction, etc. for this tenant space. Cover sheet shall include a site plan of the mall and identify or highlight the tenant space location within the mall. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. *PERMIT CO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -171 DATE: 06 -06 -12 PROJECT NAME: EXCALIBUR CUTLERY & GIFTS SITE ADDRESS: 211 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: /�(,tJ B'uilding" Division Fire Prevention Public Works n Structural Planning Division n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06 -07 -12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route III Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -05 -12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PENT CO COPY • I PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -171 DATE: 05 -22 -12 PROJECT NAME: EXCALIBUR CUTLERY & GIFTS SITE ADDRESS: 211 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: ill ding ivision VA u l i c 1 4 s ok Fire Prevention Structural Planning Dfvision Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: n Incomplete DUE DATE: 05-24 -12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: S---..11-14:)-- LETTER OF COMPLETENESS MAIJ,ED: Departments determined incomplete: Bldg l Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Ti Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: u DUE DATE: 06 -21 -12 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 City of Tukwila Department of Community Developme, 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us City of Tukwila Bob Benedicto, RA Building Official Department of Community Development 206-431-3670 6300 Southcenter Boulevard - Tukwila, Washington 98188 -8548 Fax: 206- 431 -3665 Email: bob.benedicto@tukwilawa.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6797/ 2- Plan Check/Permit Number: D 12 -171 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Excalibur Cutlery & Gifts Project Address: 211 Southcenter Mall Contact Person: ,..770-4 ✓1 —J.7 Phone Number: Summary of Revision: �q �_ _ �.�1 A440 ,t)tAed Ple& -�r/l/lr.� � co/0/02 Coo.iu p- _ i'caP� ��- . G l� ✓ p Ai; v-6 inck. khdtki lc4O r+" JUN 06 1012. . .. PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision I/ Received at the City of Tukwila Permit Center by: G.y Entered in Permits Plus on le \applications \forms - applications on Ime \revision submittal 52_11_)nne CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431-3665 E -mail: tukplanOci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ) ss. rara_ Ir. [please print nartfe] , states as follows: PERMIT NO: -)1 —/-7/ 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number J , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might ocher ise have undermost to engage an unregistered contractor to perform constructionork,/ Owner- /Owner's Agent* e law in any decision T' Signed and sworn to before me this ) 3 day of `Jail , 20 I °Z `" 1 Y PUand for the State of Washington Residing at f `1 I County Name as commissioned: .Li�� i I alta4 My commission expires: ° . 7 �/ 18.27.090 Exemptions. The regisSon provisions of this chapter do not apply to:. 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; .rti'6IIL'..aSJd.�< 18. An entity who holds a valid,ele t ical:contractor's license under chapterti9:28'RCW.tii ifemploys a certified x. tea ;,, .,. ,.;,� journeyman electrician, a:certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter :19.28 RCW to perform plumbing work that is incidentally, directly „and immediately appropriate to the like -in -kind feplacemenlof a household appliance or other snialRiousehold.utilization equipment that requires limited electric;,power and�limited waste and /or water connections`: An,electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. ABBREVIATIONS A • + AB A/C ACT ACOUS AD ADD ADJ ADJT AFF. AGO ALS ALT ANOD APPROX ARCH AUTO AF.c. B BC BD BFF. ECM BLDG BLK BLKG BM BM ao. BOT BAG B.S. BSMT BTWN BUR BPW C IORC CAB CB CEM CFI CG Cl CI CLG CLOS CLR CJ C.JT CMU COL COMP CONC C.O. C0 CONST CONT CONTR CORR CR UFA CS COAT CT CTR ow DEL DEMO DEPT DET DF DIA DWG Dirt DISP DJT DL DMT ON DO DP DR DS DSP DT DWG f L Angle At And Anchor Boit Ar Conditioning Acoustical Cefrng Tie Acoustical Area Dram Addendum Adjacent Adjustable Above R iati Roor Aggregate Area Light Standard Altrnin m Anocized Approximate Architectural Automatic Above Finish Crating E EA EF EAGG EJ EL ELEC ELEV E0.8. ENCL ENGR EP EO EOUP ES EW EDF EXIST EXP EXT Bottom d Curb Board Below Rnieh Roor Bituminous Buiding Block Blocking Bench Mark Beam Bottom d_ Bottom Bearkig Both Skies Basement Between Bull -up Roof Bed Pan Washer Charnel Cabinet Catch Bash Cement Contractor Firniehed and keeled Corner Guard Contractor installed Only Cast iron Cellag Closet Clear Contraction Joint Control Joht Concrete Masorry tklt Column Composition Concrete Concrete Opening Connection Construction Continuous Contractor Corridor Contractor Rough-In Contractor Removed, Relocated + Reinstalled Cu* otntere Construction Joint Casement Ceramic Tie Center Center fine Cold Water F East Each Each Face Exposed Aggregate Expansion Joint Eievaticn Bectrical Elevator Edge d Slab Encoetre atncal Panel Equal Equpment Each Side Each Way Electric is Drkkhg Fountain Biding Expansion Exterior FA FAST FB R30 FD FDN FE FEC FF RIO Fit FL RASH FLUOR FO FOC FOF rOM FOS FOTS FRT FT FTG Fly Fire Alarm Fastener Rat Bar Furnished by Others Roor Drain Fotnchtion Fire Extinguisher Fire Extinguisher Cabinet Finish Roor Fire Hose Cabinet Fah Roor Ruoreecent Face at Face at Concrete Face of Firth Face of Masonry Face of Stud Face of Tare Section Fire Retardant Treated Foot or Feet Foothg F Length Laboratory Laminate Lavatory Lag Boit Lees Door Width Landscape island Locker Live Load Landscaping Ught Louver MATL MAX M3 MC kCO MED 1.13.413 MEZZ MFR Mil MiN MEI MSC MO MTD MiL MULL MEDCAB GA GALV GB GC GL GL Gt3 GP GAD GYP N Gauge Galvanized Grab Bar General Contractor Galvanized iron Glass Glu Lam Ground GaNarized Pipe Grade Gypsum Veneer Fleeter Gypeumm Board H3 HC HC HDWD HDWR HM HOFiZ HR H. HVAC HW Double Demoish Department Detail Drinking Fountain Diameter Diagonal Dimension Dispenser Defection Joint Dead Load Demountable Down Door Opening Damprooling Door Downspout Dry Standpipe Drab Tie Drawing Diameter or Round Hose Blab Holm/ Core Handcep Parking Staff Hardwood Hardware Hollow Metal Horizontal Hour Hektit HeatingNentiathg/ At Concitioning Hot Water MIL PS J haide Diameter (Dim) insuation interior Wert Iron Pipe Size N Material Mexirnm Machine Blot tufneral Core Medium Density Overlay Mechanical Medlin Membrane Mezzruhe Manufachrer Manhole Maleeble ton Maim= Mirror AMceianeoue Masonry Opening Mounted Metal Mutiion Medche Cabinet N North NA Not Appicable NAT Natural MC Not h Contract NO. OR It Number NOM Nominal NS Nelson Stud NTS Not to Scale MS Not in Shei Issue 0 R R RA RB RD FEF FEFt_ FERI REEF REM_ FEO'D REV RM RO. RWL RCP S Beer Radius Retun Air Rubber Base Rod Drain Reference Reflected Refrigerator Reinforced Reeiient Requied Revise or Revision Room Rough °Penh) Rain Water Leader Reflected Ceifng Plan S SC. sc o SCHED SD SECT SGE SH SHTG SHWR SIT SJ SL SM Sly SPEC SO SS S+V STA STD STK sn STOR STRUCT SUB' SYM SYST South Sold Core Seat Cover Dispenser Schedue Soap Dispenser Section Seni-glose Enamel awilf Sheathing Shower Sheet slier Sefemic Joint Siding Sheet Metal Sanitary Napkin Dispenser Sanitary Napkin Receptacle motion Squire Stainless Steel State + Varnish Station Standard Stock Steel Storage Sructiral Symmetrical System OA Overall T OBS Obscure OC On Center T Tread CO Outside Diameter TB Towel Bar OF. Owner Furnished, T + B Top and Bottom OF.Cl Owner Furnished, TC TEL Telephone kidded TEMP Tempered OFF. Office OH Over Head T + 0 Tongue and Groove OPNG Opening THK Thick OPP Opposite TJ Tod Joint OS Outside TP Top of Pavement OR Owner Furnished TPD Toiet Paper Dispenser + hataled TPD(S) Surface Mounted Toilet Paper Dispenser T8 Tube Section TV Television TW Top of Wall TYP Typical F PAR PC PP PJ PL P. LAM FLAB PLYWD PR PFEF#1 P.T. PTD PTDR PTN PTR PVC PVMT JAN Jr JST K Janitor Joint Joist Q Paraiel Precast Poured in Place Panel Joint Property Line Plastic Latinate Piaster Flimood Pei Prefriehed Pressure Treated Paper Towel Dispenser Combination Paper Towel Dispenser + Receptacle Partition Paper Towel Receptacle Polyvinyl Pavement KIT KD Kitchen Kin Dried OT Quarry Tie iDDEIR DESiCIN ELECTRICAL CRITERIA 1. ANY ELECTRICAL WORK, IF NEEDED, TO BE DONE UNDER A SEPARATE PERMIT. 2. ELECTRICAL DESIGN CONTRACTOR TO PROVIDE ANY NECESSARY DRAWINGS. U Ul•t UR U /CUT UN.O. V lktirriahed Urinal Under Cult Unless Noted Otherrriae ve VERT VEST WY VG W Vapor Barrier Vertical Veetbie Verify Vertical Grain Width West With Water Closet Widow Dinension Wood Wide Range Wtregiase Water Heater Window Without Waterproof Wateratop Wainscot Weight Welded Wre Fabric EXCALIBUR STORE T NANT IMPROVEMENT THIS PROJECT CONSISTS OF PROVIDING NEW CASEWORK IN AN EXISTING SPACE NO CHANCES TO THE EXISTING CE iL iNG, FLOORING OR RESTROOM. Pe.K ; i--- 01 / `/' e ev. reA, s7,u /4thad6 et, ,bW) d L t- c c>471)(bled bin GENERAL NOTES: Rekif4,7 i !S C , 2/ (1- -- (./ 1'0 C- 0/0 e - ALL WORK TO COMPLY WITH THE REQUIREMENTS OF CITY OF TUKWILA. THE CURRENT EDITIONS OF INTERNATIONAL BUILDING CODE, MECHANICAL, PLUMBING AND FIRE CODES. ANY BUILDING OFFICIAL, SUBCONTRACTOR OR TRADESPERSON NOTING DISCREPANCIES SHALL NOTIFY THE DESIGNER IMMEDIATELY UPON DISCOVERY. 1. CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS BY CITY OF TUKWILA, AND ANY OTHER GOVERNING AUTHORITIES AS REQUIRED. 2. CONTRACTOR SHALL VERIFY AND CONFIRM EXISTING CONDITIONS SHOWN OR IMPLIED ON DRAWINGS PRIOR TO THE START OF CONSTRUCTION OR ORDERING MATERIALS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL TEMPORARY UTILITIES INCLUDING ELECTRICITY NECESSARY FOR CONSTRUCTION. 4. ALL CONSTRUCTION DEBRIS TO BE NEATLY STOCKPILED ON SITE UNTIL DISPOSAL. ALL DEBRIS IS TO BE DISPOSED OF IN A LEGAL MANNER AT A LANDFILL OR RECYCLING CENTER. NO DEBRIS IS TO BE DISPOSED OF IN LOCAL WASTE COLLECTION FACILITIES. 5. CONTRACTOR SHALL INFORM THE DESIGNER OF ANY AND ALL REQUESTED CHANGES. CONTRACTOR SHALL NOT PROCEED WITH REQUESTED CHANGES OR DIRECTIVES WITHOUT PRIOR AUTHORIZATION FROM THE DESIGNER AND A WRITTEN CHANGE ORDER. 6. CONTRACTOR SHALL PROVIDE STORAGE FOR ALL BUILDING MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 7. ALL SUBSTITUTIONS MUST BE APPROVED BY DESIGNER, ALONG WITH WRITTEN REQUESTS CONTRACTOR SHALL PROVIDE ALL INFORMATION REGARDING THE SUBSTITUTION IN QUESTION, INCLUDING COST. 8. SOLID WOOD BLOCKING, INSULATION, OR OTHER FIRE STOP MATERIAL IS TO BE PROVIDED, BETWEEN TOP STORY AND ROOF FACE, IF REQUIRED. 9. CONTRACTOR SHALL PROVIDE SAMPLE OF FINISHES AND STAIN COLORS FOR APPROVAL BY DESIGNER. THIS INCLUDES INTERIOR AND EXTERIOR PAINT, AND GYP. BD. TEXTURES. 10. WRITTEN DIMENSIONS AND NOTES ON DRAWING SHALL TAKE PRIORITY OVER SCALE OF DRAWINGS. DO NOT MEASURE DRAWINGS TO DETERMINE ANY DIMENSIONS. DRAWINGS ARE IN SCALE FOR PURPOSES OF DESIGN AND INTENT ONLY. ALL DIMENSIONS SHOWN PLANS ARE FROM AND TO FACE OF FINISHES OR FROM AND TO CENTERLINE OF WALLS, UNLESS OTHERWISE NOTED. 11. ALL FEATURES OF THE WORK NOT FULLY SHOWN SHALL BE OF THE SAME TYPE AND CHARACTER OF THAT SHOWN FOR SIMILAR CONDITIONS. IN THE EVENT OF THAT ADDITIONAL WORK IS REQUIRED TO COMPLETE THE WORK AS INTENDED OR REQUIRED BY GOVERNING CODES, YET NOT FULLY SHOWN OR OMITTED BY IN THE DRAWINGS, CONTRACTOR(S) MUST STILL PROVIDE FOUNDATION, CARPENTRY, MECHANICAL, ELECTRICAL AND OR/ PLUMBING AS REQUIRED FOR CERTIFICATE OF OCCUPANCY, INCONSISTENCIES, OR DISCREPANCIES. 12. VERIFY ALL DIMENSIONS AND MFR. SPECIFICATIONS OF OWNER FURNISHED EQUIPMENT PRIOR TO CONSTRUCTION. 13. CONTRACTOR RESPONSIBLE TO ENSURE ALL FINISHES AND FIXTURES MEET ADA CODES. PROJECT DATA BUILDING LOCATION: SCOPE OF WORK: AREA OF REMODEL: SALES AREA: STOCKROOM: COIL SUMMARY 2897 Southcenter Mall, Space 211 Tukwila, WA 98188 TENANT IMPROVEMENT 600 SQ. FT. 600 SQ. FT. / 30 = 20 OCCUPANTS 140 SQ. FT. / 200 = 1 OCCUPANT 21 TOTAL OCCUPANTS SINGLE EXIT ALLOWED SECTION I - GOVERNING CODES 1. APPLICABLE CODES AND STANDARDS: et elBC AND UPC W/ WASHINGTON AMENDMENTS SECTION GENERAL BUILDING DATA 1. NUMBER OF STORIES: 1 2. FIRE SPRINKLERS YES SECTION IV - BUILDING OCCUPANCY DATA 1. OCCUPANCY CLASSIFICATION M TENANT SPACE MALL MAP GROUND FLOOR t PROJECT TEAM BUILDING OWNER: CONTACT: TENANT: CONTACT: ARCHITECTS: CONTACT: DAVID HARDISTER AIA CONTRACTOR: WESTFIELD GROUP SCOTT PRIESTER EXCALIBUR P.O. BOX 2687 EUGENE, OREGON 97402 JOHN JOST JOHN @EXCALIBUREMAIL.COM WESTERN DESIGN GROUP, INC 4612 NE MINNEHAHA ST. VANCOUVER, WA 98661 TBD DRAWING INDEX Ph. 541.484.7445 Ph. 360.699.5317 fax 360.694.7818 REVISIONS No change, shall he made to the scope ci rtithc ut prior approval of l Tukwila Building Division. N:73: .:;v :lions will require a new plan submittal and may include additional plan review fees. SHEET NUMBER A0.0 A1.0 A2.0 SHEET TITLE COVER SHEET AND VINCINITY MAP FLOOR PLAN AND CEILING PLAN INTERIOR ELEVATIONS FELE COPY Pe eG it no. i- fit: is QED FOR: RPt.%)chanical Istrical riumbing cAras Piping cf Tukwila h ' 'G DIVISION i PIP' review new approval is subject to errors and omissions. L,;.,-:• ,/ ; of construction documents does not authorize t,,, do n of any adopted code or ordnance. Roceil t o Lp ra ved Field 2y and acknowledged: By j macys Mid JCPe ney E Date: City Of Tukwila BUILDING DIVISION VICINITY MAP G N s 'etid S + {Y It — —4 ,A in Sts ?np St s• S i53re St ,i Pkm, 9aV^ Tuk.A Park ' N seocertttttt" • • Turwiia Pkwy ter y, 3 thatS C•S. D S 1614= I•SIh St S td!: tea r tl P7. a Kfch�� S1 ttr, t INCOMPLETE LTR# b1)- Stsarsdc, Svc REVIEWED FOR CODE COMPLIANCE APPROVED IJUN 1 3 2012(, )^ W► City of Tukwila BUILDING DIViSiON J RECEIVED JUN 06 2012 PERMIT CENTER 4612 NE Minnehaha St. Vancouver, WA 98661 ® WA phone: 360-699 -5317 OR phone: 503-222-9296 fax: 360-694-7818 SHEET TITLE REUSE OF DOCUMENTS This document, and the ideas and designs incorporated, as an instrument of professional service is the property of Western Design Group, Inc. and is not to be used, in whole or in part, for any reason without the written authorization of Western Design Group, Inc. DATE ISSUE 12.6.11 REVIEW 2.27.12 OUTLETS DRAWN BY CHECKED BY DH DH JOB # : 10 -4076 SCALE: AS NOTED SHEET NUMBER A0.0 141Z • MALL COMMON AREA D D D D X 05 D D A 0 NORTH REFLECTED CEILING PLAN 1/4" = 1' -0" ,54dL Oa, 60 I _(0 occe2 ieem s/1- ace& keil/ea — ce,,dpa,v1 --A-L6 Zz cbce)a.th N 0 1, -2 1/8' N r r 3/' e SHARPENING S' -0' POS 2'- 1' -" MIN CABINET FROM TENANTS EXISTING STOCK. INSTALL CARPET OVER NEW PLYWD. TOP. 16' -0' QINN°RTH FLOOR PLAN 1/4" = 1' -0" bs1)171 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 1 3 2012 City of Tukwila BUILDING DIVISION RECEIVED MAY 2 2 2012 PERMIT CENTER 6 I • 2 SHEET TITLE REUSE OF DOCUMENTS This document, and the ideas and designs incorporated, as an instrument of professional service is the property of Western Design Group, Inc. and is not to be used, in whole or in part, for any reason without the written authorization of Western Design Group, Inc. DATE ISSUE 12.6.11 REVIEW 2.27.12 OUTLETS DRAWN BY DH CHECKED BY DH JOB # : 10 -4076 SCALE: AS NOTED SHEET NUMBER A1.0 SHARPENING STATION NEW CONTINUOUS 1x4 WOOD TRIM TO MATCH CABINETS LATWALL —� LATWALL DISPLAY CABINET Ch o _ \ e 1 II 8' -6" 1 6' -0" k 6' -0" ELEVATION - CUSTOMER SIDE 3/8" = 1' -0" ♦ l i0) 0 C." 0 BACK BAR KITCHEN KN FE –\ ANGLE) DISPLAY WALLS. O 0 0 0 BLACK MELAMINE SLIDING CABINET DOORS 0 0 0 1 r ELEVATION - BACK BAR FPAINTED GYP. B. CONTINUOUS 1x4 WOOD TRIM a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DISPLAY CABINETS, 6' -0" 4' -0.. 4._0.. 6._0.. ELEVATION - DISP[LAY CABINETS 3/8" = 1' -0" 1 ELEVATION - POS 3/8" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED I JUN 13 2012 City of Tukwila BUILDING DIVISION RECEIVED MAY 222012 PERMIT CENTER w z SEATTLE, WA SHEET TITLE REUSE OF DOCUMENTS This document, and the ideas and designs incorporated, as an instrument of professional service is the property of Western Design Group, Inc. and is not to be used, in whole or in part, for any reason without the written authorization of Western Design Group, Inc. DATE ISSUE 12.6.11 REVIEW 2.27.12 OUTLETS DRAWN BY DH CHECKED BY DH JOB # : 10 -4076 SCALE: AS NOTED SHEET NUMBER /2.O o e 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DISPLAY CABINETS, 6' -0" 4' -0.. 4._0.. 6._0.. ELEVATION - DISP[LAY CABINETS 3/8" = 1' -0" 1 ELEVATION - POS 3/8" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED I JUN 13 2012 City of Tukwila BUILDING DIVISION RECEIVED MAY 222012 PERMIT CENTER w z SEATTLE, WA SHEET TITLE REUSE OF DOCUMENTS This document, and the ideas and designs incorporated, as an instrument of professional service is the property of Western Design Group, Inc. and is not to be used, in whole or in part, for any reason without the written authorization of Western Design Group, Inc. DATE ISSUE 12.6.11 REVIEW 2.27.12 OUTLETS DRAWN BY DH CHECKED BY DH JOB # : 10 -4076 SCALE: AS NOTED SHEET NUMBER /2.O