HomeMy WebLinkAboutPermit D12-172 - HILL-ROM - TENANT IMPROVEMENTHILL-ROM
12610 INTERURBAN AV S
D12 -172
City OTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 0004800003
Address: 12610 INTERURBAN AV S TUKW
Suite No:
Project Name: HILL -ROM
Permit Number: D12 -172
Issue Date: 06/06/2012
Permit Expires On: 12/03/2012
Owner:
Name: GATEWAY OLYMPIA INC
Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261
Contact Person:
Name: TORJAN RONHOVDE
Address: 14900 INTERURBAN AV S, #138 , TUKWILA WA 98168
Contractor:
Name: BOYCE CONSTRUCTION
Address: 270 S HANFORD ST #109 , SEATTLE WA 98134
Contractor License No: BOYCECI066QQ
Lender:
Name:
Address:
Phone: 206 859 -5500
Phone: 206 - 264 -8085
Expiration Date: 01/21/2014
DESCRIPTION OF WORK:
NEW TENANT: ADD APPROXIMATELY 220 SF NEW OFFICE AND NEW ACCESSIBLE TOILET ROOM TO AN EXISTING
OFFICE WAREHOUSE. ALL WORK WILL BE INTERIOR WITH THE EXCEPTION OF A NEW WAREHOUSE LEVEL EXIT DOOR
AND STAIR.
Value of Construction: $35,000.00 Fees Collected: $1,215.02
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009
Type of Construction: IIIB Occupancy per IBC: 0024
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -172 Printed: 06 -06 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
e a
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature: Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name: 11 Ik -r-\-. E rZ (..c
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date:
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDFI'IONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
doc: IBC -7/10
D12 -172 Printed: 06 -06 -2012
7: All construction shall be done in confo a with the approved plans and the require of the International
Building Code or International Residential, International Mechanical Code, WashingliPtate Energy Code.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: ** *FIRE DEPARTMENT CONDITIONS * **
15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
doc: IBC -7/10
D12 -172 Printed: 06 -06 -2012
25: Exit hardware and marking shall meet tlequirements of the International Fire Code. (Chapter 10)
26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads. (IFC 901.4)
28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
29: All new sprinter systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327).
30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2328)
31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC
104.2)
32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and
#2328)
34: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206) 575 -4407.
doc: IBC -7/10
D12 -172 Printed: 06 -06 -2012
CITY OF TUKJA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http: / /www.TukwilaWA.gov
Building Pe t No. b t2 -112
Project No.
Date Application. Accepted:
Date Application Expires:
For of ice use on
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION + 262i p \ GT-La2..0 /Q 11/40U-
King Co Assessor's Tax No.: L 4 3
Site Address: t 2 6 i v k, IOT lg—‘6 AK—F— S Suite Number: Floor:
Tenant Name: .* L " Fa 44 New Tenant: .... Yes 1=1.. No
PROPERTY
\\ In
Name: -�6v.T�1"0� �� cA/Pe
c�
—OWNER
Name c� ���'t, G" 1wf1Ci
Address:t 1 �,.,;� r �tev,,,� N t. SS L j6
Tj `
Address:R7 00 7�1..
Address:
City State
Zip:/
-4ca 1 e
CONTACT PERSON — person receiving all project
communication
\\ In
Name: -�6v.T�1"0� �� cA/Pe
c�
Address: S
Address:t 1 �,.,;� r �tev,,,� N t. SS L j6
Tj `
Citp:} -u , ) vioi
State :P >t 1 A Zip:ggmze
Address:
ET- gra,aW 0 roli kaveiea v h fe t5 • c
City:
State:
Zip:
Phone:
Zip:
Fax:
Fax:
Email:
State:
Contr Reg No.:
Phone:
GENERAL CONTRACTOR INFORMATION
Company Name:
Architect Name;-1-612 fJ D6
Address:t 1 �,.,;� r �tev,,,� N t. SS L j6
Tj `
Citp:} -u , ) vioi
State :P >t 1 A Zip:ggmze
Address:
ET- gra,aW 0 roli kaveiea v h fe t5 • c
City:
State:
Zip:
Phone:
Fax:
State:
Contr Reg No.:
Phone:
Exp Date:
Fax:
Tukwila Business License No.:
Email:
H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
ARCHITECT OF RECORD
Company Name: irtrAt , lit P
Architect Name;-1-612 fJ D6
Address:t 1 �,.,;� r �tev,,,� N t. SS L j6
Tj `
Citp:} -u , ) vioi
State :P >t 1 A Zip:ggmze
Phone:205 'd 'SroU Fax: 593./
ET- gra,aW 0 roli kaveiea v h fe t5 • c
ENGINEER OF RECORD
Name:
Address:
Company Name: j("� I
11
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATIO- 206 - 431 -3670
Valuation of Project (contractor's bid price): $ 6213
•
Existing Building Valuation: $ )CX(ij G-C)
Describe the scope of work (please provide detailed information): 1447P Ij
C
Cs
Cu 004- 1 012-
Will there be new rack storage? ...Yes
❑ ..No
If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use? ❑ Yes
2S^
x
Compact:
Handicap:
No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Sa ety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBBC
Type of
Occupancy per
lat Floor
"74ci ;oW
Zs-b
�° 1/
/BC
J- ]
rd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
•
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use? ❑ Yes
2S^
x
Compact:
Handicap:
No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Sa ety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
Page 2 of 4
PUBLIC WORKS PERMIT INFTION — 206 - 433 -0179
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ .. Tukwila ❑ ...Water District #125
❑ .. Water Availability Provided
Sewer District
❑ .. Tukwila
❑ .. Sewer Use Certificate
❑... Highline
❑...Valley View ❑...Renton
❑ ...Sewer Availability Provided
0... Renton
0... Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ")
❑ .. Technical Information Report (Storm Drainage)
❑ .. Bond 0... Insurance 0... Easement(s)
Proposed Activities (mark boxes that apply):
❑ .. Right -of -way Use - Nonprofit for less than 72 hours
❑ .. Right -of -way Use - No Disturbance
❑ .. Construction/Excavation /Fill - Right -of -way ❑
Non Right -of -way ❑
❑ .. Total Cut
❑ .. Total Fill
cubic yards
cubic yards
❑ .. Sanitary Side Sewer
❑ .. Cap or Remove Utilities
❑ .. Frontage Improvements
❑ .. Traffic Control
❑ .. Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Permanent Water Meter Size (1)
❑ .. Temporary Water Meter Size (1)
❑ .. Water Only Meter Size
❑...Geotechnical Report
U... Maintenance Agreement(s)
❑ .. Traffic Impact Analysis
❑ .. Hold Harmless — (SAO)
❑ .. Hold Harmless — (ROW)
0... Right-of-way Use - Profit for less than 72 hours
0... Right-of-way Use — Potential Disturbance
❑... Work in Flood Zone
❑... Storm Drainage
0... Abandon Septic Tank
❑... Curb Cut
0... Pavement Cut
0... Looped Fire Line
❑ .. Sewer Main Extension Public
❑ .. Water Main Extension Public
f>
WO #
WO #
WO #
Private ❑
Private ❑
U... Grease Interceptor
❑... Channel ization
0... Trench Excavation
❑... Utility Undergrounding
(2) " WO # (3) " WO #
(2) " WO # (3) " WO #
❑ .. Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City
Water Meter Refund/Billing:
Name:
Mailing Address:
State Zip
Day Telephone:
City
State Zip
H:Wpplications'Forms- Applications On Line \2012 Applications\Pennit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILD
Sign
IZED AGENT:
Print Name:
Mailing Address: /P%(i 1 v l--e ru ith -fal/ m
S, L 06 /q W - Tyid
City State Zip
Date:
/2-
/ " 74 / �'Q/�0�/ f %i /Th Day Telephone: �—(.6 - Y" / --JsKJ
H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- I2.docx
Revised: February 2012
bh
Page 4 of 4
. •
C City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.aov
RECEIPT
Parcel No.: 0004800003 Permit Number: D12-172
Address: 12610 INTERURBAN AV S TUKW Status: APPROVED
Suite No: Applied Date: 05/23/2012
Applicant: HILL -ROM Issue Date:
Receipt No.: R12 -01793
Payment Amount: $738.15
Initials: JEM Payment Date: 06/06/2012 12:20 PM
User ID: 1165 Balance: $0.00
Payee: MATTHEW FITZGERALD, BOYCE CONSTRUCTION
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd MC
Authorization No. 00420Z
ACCOUNT ITEM LIST:
Description
738.15
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 733.65
640.237.114 4.50
Total: $738.15
doc: Receiot -06 Printed: 06 -06 -2012
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.Tukwila WA.gov
RECEIPT
Parcel No.: 0004800003 Permit Number: D12 -172
Address: 12610 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 05/23/2012
Applicant: HILL -ROM Issue Date:
Receipt No.: R12 -01656
Payment Amount: $476.87
Initials: JEM Payment Date: 05/23/2012 08:18 AM
User ID: 1165 Balance: $738.15
Payee: RONHOVDE ARCHITECTS LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1168 476.87
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 476.87
Total: $476.87
doc: Receiot -06 Printed: 05 -23 -2012
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
1)/2 -172_
Project:
/{r /f Woo/
Type of Inspection:
ri A.J4 L
Address:
/?solo ...�✓,, /),r,b4„,/
Date Called:
Special Instructions:
Date Wanted:.
a- /3-/2
(a rn)
p.m.
Requester:
•
Phone No: _
AO
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
'1?;,/,-.) i^'
(,-/
1''
/4/
•
(
n R INSPECTION FEE REQUIRED. Prior to
R at 6300 Southcenter Blvd.. Suite 100.
Date
c7-- /3-1?
next inspection, fee must be
Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
� //
/ - /�--/?0,-;-')
Type of
c -.,,1"9 t
Address:
/2 6/0 _7",✓7.1,,w/6'9
Date Called:
A i d / 00(7200e/ A,A 2 f / o i S F o R ' Z/sF / ( C . -
) /2// -R,- Rtiti k , rivii l (,,tb /4 --4s
Special Instructions:
Date Wanted:.
7.- 2-6
/
err ..
p.m.
Requester:
Phone No:
„206. -z
-6V5'3
Approved per applicable codes:
Ncorrections required prior to approval.
COMMENTS:
0 fp#l/1yf,e,4/ / ?rn ''< ,'.4/6. /4252-4,e1,(13
cip,sr741.>. ...21,&14 / 4 71;7.1/ d i z $
?m.) ,9.P& / 4,- /7/fete 12'/»2 00
A i d / 00(7200e/ A,A 2 f / o i S F o R ' Z/sF / ( C . -
) /2// -R,- Rtiti k , rivii l (,,tb /4 --4s
o /4/a h f�4 e/L7 ., 2--- /at e 5'3 /,r-- , ,S444/-4 /
/ .--ref •
nspe tort
Date:
REJNSPECTION FEE REQUIRED. Prior to next inspection. fee must be
id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 '• .F., (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
/1/1.1- — /?(:),Y1
Type of Inspection: `
_S-? CS PFn/.a .D (Vet L /rV
Address:
/2 616 .zN 7-c,77/Rd/
Date Called:
Special Instructions:
(741/ ,q
6 G/33/ —O/
Date Wanted: .
- 7-- /a_ /7
(rill;
m.
Requester:
Phone No:
,.,10 6 -.2ss —65'5'
3
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
�vC_,.� ✓�NKL ®-c".J
pector
Date: Q
—1 ^ c J r
REINSPECTION FEE)REQUIRED. Prior to next inspection, fee must be
paid/at 6300 Southcenter Blvd.: Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
t12 -1-7'7
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
E..LL - OW\
Type of Inspection:
E.R.h- AA ,fu (.,
Address:
1 a--(ni 0 a. N
-ti.R. 3 A a. )
Date Called:
Special Instructions:
Date Wanted:.
G-.Z? —c Z
arr
pem:
Requester:
Phone No:
n.Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Date:
EINS ECTION FEE REQUIRD. Prior o next inspection. fee must be
paid - 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
i
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
R--s - iY_
era• /7
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project: ` / ROA/i
/
T ype oA Ins ection:
pe r N A L
Address: 2. (, (U I� p S
Suite #:
Contact Person:
Tope , ,a r)
0_0 A) )---\-OUJ�
Special Instructions:
Permits: -
Phone No.:
N. Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
AJA( O
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits: -
Occupancy Type:
Inspector:
4 L.
S ,co--
Date: 7 /as //Z
Hrs.: 1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
*EMIT COORD COP*
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -172
PROJECT NAME: HILL -ROM
SITE ADDRESS: 12610 INTERURBAN AV S
DATE: 05/23/12
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
Building Division ® Fire Prevention ® Planning Division
DtthA IVA" Public Works Structural n Permit Coordinator n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 05/24/12
Not Applicable n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required n No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 06 /14/12
Approved n Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
02/29/12
Contractors or Tradespeopleter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
BOYCE CONSTRUCTION INC
2062648085
270 S Hanford St 109
Seattle
WA
98134
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
601538339
Active
BOYCECI066QQ
Construction Contractor
11/18/1994
1/21/2014
General
Unused
ther Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
BOYCEC *088Q0
BOYCE
CONSTRUCTION
Construction
Contractor
General
Unused
11/20/1992
11/18/1994
Archived
MBCON "095P5
M B
CONSTRUCTION
Construction
Contractor
General
Unused
10/10/1991
10/4/1992
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BOWELL, ROBERT
Cancel Date
01/01/1980
Amount
BOWELL, SHERI
11
01/01/1980
ACPACT07504265684
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
DEVELOPERS SURETY
& INDEM CO
178017C
11/18/2001
Until Cancelled
$12,000.00
12/07/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
11
NATIONWIDE
MUTUAL INS CO
ACPACT07504265684
11/18/2010
11/18/2012
$1,000,000.00
09/27/2011
10
NATIONWIDE
MUTUAL INS CO
ACP7504265684 '11/18/2009
11/18/2010
$1,000,000.00
11/18/2009
9
WEST
AMERICAN INS
CO
BKA53689407
11/18/2008
11/18/2010
$1,000,000.00
10/21/2009
8
WEST
AMERICAN INS
BKS53689407
11/18/2007
11/18/2008
$1,000,000.00
11/08/2007
7
HARTFORD CAS
INS CO
52SBANQ4473
11/18/2002
11/18/2008
$1,000,000.00
09/26/2007
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
06/06/2012
GENERAL NOTES:
I PLEASE NOTIFY ARCHITECT IF ANY DISCREPANCIES EXIST. WITHIN THE DRAWINGS.
2 THE DRAWINGS FOR THIS PROJECT ARE CONSIDERED TO BE "OWNER/BUILDER
TYPE" AND ARE INTENDED TO DOCUMENT THE GENERAL CONSTRUCTION
SYSTEMS WHICH MEET MINIMUM BUILDING CODE STANDARDS. CHANGES IN
THESE SYSTEMS MAY RESULT IN CONSTRUCTION THAT DOES NOT MEET MINIMUM
CODE OR CONFLICTS WITH OTHER WORK STANDARDS. ANY CHANGES NOT
APPROVED IN WRITING ARE THE RESPONSIBILITY OF THE CONTRACTOR OR
SUB- CONTRACTOR MAKING THE CHANGES.
3 ALL METHODS, MATERIALS 4 WORKMANSHIP SHALL CONFORM TO THE 200q
IBG AS AMENDED AND ADOPTED BY THE LOCAL JURISDICTION COMPLY WITH
ALL APPLICABLE CODES 4 ORDINANCES:
4 THE CONTRACTOR AND SUB - CONTRACTOR SHALL CAREFULLY STUDY AND
COMPARE THESE DRAWINGS WITH EACH OTHER AND WITH INFORMATION
FURNISHED BY THE TENANT. ANY ERROR5, INCONSISTENCIES OR OMISSIONS
DISCOVERED SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY IN
WRITING. THE CONTRACTOR SHALL NOT BE LIABLE FOR THE ABOVE UNLESS
THE CONTRACTOR (SUB) RECOGNIZED SUCH ERROR, ETC., DID NOT REPORT
SUCH ERROR AND PROCEEDED WITH THE CONSTRUCTION. INSTALLATION
DRAWINGS FURNISHED BY THE TENANT TAKE PRECEDENCE OVER THESE
5 GDON I KAGG 10R, SUB - CONTRACTOR 4 MATERIAL SUPPLIERS TO VERIFY FIELD
CONDITIONS WHICH EFFECT THEIR WORK PRIOR TO FABRICATION OR
CONSTRUCTION.
6 SHOP DRAWINGS, PRODUCT DATA AND SAMPLE APPROVAL ARE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR. DO NOT SCALE THE
DRAWINGS.
1 UNLESS OTHERWISE NOTED, PLANS ARE DIMENSIONED TO FACE OF STUDS.
8 VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS
CONTRACT OR BY OTHERS.
q VERIFY SIZE LOCATION OF 4 PROVIDE ALL OPENINGS THROUGH FLOORS &
WALLS. FURRING CURBS, ANCHORS, INSERTS, MACHINE BASES AND ROUSH
BUCKS BACKING FOR SURFACE- MOUNTED ITEMS. JOIST NOTCHING AND HOLE
BORING SHALL COMPLY WITH IBC AND /OR JOIST MANUFACTURE.
10 REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE 4 SHALL BE
COMPLETELY PROVIDED AS IF DRAWN IN FULL. ITEMS REFERRED TO AS
SINGLE MAY BE PLURAL.
II VERIFY LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION.
12 ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS
OR DETAILS SHALL BE 4" FROM FACE OF STUD TO EDGE OF DOOR OPENING
OR CENTERED BETWEEN ROOM PARTITIONS AS SHOWN.
13 FINISH FLOOR (FIN. FLR.) REFERS TO TOP OF PLYWOOD OR LT. WEIGHT GONG
UNDERLAYMENT OR CONCRETE SLAB.
I4 TYPICAL FRAME PARTITIONS, ARE 3 -I /2 ", 25 GA. MTL 5T105 SPACED @ 24"
O.G. UNLESS NOTE OTHERWISE. SEE WALL SCHEDULE FOR TYPE - SEE FLOOR
PLAN FOR LOCATION.
15 REFER TO SCHEMATIC CABINET DRAWINGS FOR CABINET, COUNTER LENGTHS,
DIMENSIONS, COUNTERTOP MATERIALS AND DETAIL REFERENCE. CABINET
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
16 ELECTRICAL/MEGHANICAL/PLUMBING /APPLIANCES:
A. I IVAG CONTRACTOR TO PROVIDE I 'EATING LOAD CALCULATIONS TO TI IC
LOCAL JURISDICTION FOR APPROVAL PRIOR TO CONSTRUCTION
(WITHIN I m00% Or CALCULATED HCAT LOSS). ALL HVAG INSTALLATIONS
51 IALL MELT APPLICABLE STANDARDS
OWNER /CONTRACTOR COORDINATION NOTES :
THE FOLLOWING NOTES SHALL SERVE AS A GUIDE TO THE CONTRACTOR TO VERIFY EACH
CONDITION EITHER THE PRODUCT MANUFACTURER OR SUPPLIER, AND /OR LOCAL
JURISDICTIONS FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE OWNER OR
PROCEED INS WITH THEIR WORK.
THE ITEMS OUTLINED BELOW ARE NOT INTENDED TO BE AN EXHAUSTIVE ANALYSIS OF ALL.
POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE AS A BEGINNING
POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE GON5TRUGTION PROCESS.
I. REVIEW MANUFACTURER'S PRODUCT LITERATURE AND GENERAL NOTES. FOR.
INSTALLATION INSTRUCTIONS UNIQUE TO THE PROJECT CONSTRUCTION TYPE
A. RECEPTACLE BOXES (I.E. T.V., TELEPHONE, ELECT., PLUMBING)
B.
G.
2. REVIEW LOCAL JURISDICTION REQUIREMENTS FOR COMPLETE INSTALLATIONS OF
THE FOLLOWING
A. FIRE SPRINKLER SYSTEM AS REQUIRED
B c AS RCQUIRCD
C. FIRE EXTINGUISHER SIZE AND LOCATION
3. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY WITH LOCAL
JURISDICTIONAL REQUIREMENTS.
B. TELEPHONE
. TRASH SERVICE :
F WATER UTILITY
SCMCNTS) :
HILL —ROM
TENANT IMPROVEMENT
12610 INTERURBAN AVENUE SOUTH
TUKWILA, WA 98168
ABBREVIATIONS
ASSEM. ASSEMBLY
BD. BOARD
BLDG. BUILDING
BM. BEAM
BSMT. BASEMENT
GONG. CONCRETE
CONT. CONTINUOUS
CONTROL JOINT
CLOTHES DRYER OR DUMPSTER
D.W. DISHWASHER
EA. EACH
EXIST. EXISTING
EXT. EXTERIOR OR FIRE EXTINGUISHER
ELEV. ELEVATION
F.H. FIRE HYDRANT OR FAIR-HOUSING
F.0.1 .G. FURNISHED BY OWNER INSTALLED BY CONTRACTOR
FTC. FOOTING
G.S.B. GYPSUM SHEATHING BOARD
G.W.B.. GYPSUM WALL BOARD
H/C HANDICAP
HORIZ. HORIZONTAL
HP5 HIGH PRESSURE SODIUM LIGHT
HTR HEATER
HVAC HEATING VENTILATION AND AIR CONDITIONING
INSUL. INSULATION
INT. INTERIOR
LAV. LAVATORY
MAX. MAXIMUM
MIN. MINIMUM
O.G. ON CENTER
0.F.O.I. OWNER FURNISHED OWNER INSTALLED
0.5B. ORIENTED STRAND BOARD
PLYND. PLYWOOD
P.T. PRESSURE TREADED FOR RESISTANCE TO
WATER DECAY
REF. REFRIGERATOR
R/5 ROUGH SAWN
SHR. 5HEAR
SHWR. SHOWER
5PR. SPRINKLER RISER ROOM
5.F. SQUARE FEET
50. FT. SQUARE FEET
TYP. TYPICAL
T.V. TELEVISION
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTIGAL
W CLOTHES WASHER
V4/G WATER • CLOSET
MM. WINDOW
SITE PLAN
NOT TO SCALE
ENERGY CODE NOTES
THERE 15 NO WROK PROPOSED TO THE BUILDING SHELL.
EXISTING BUILDING SHELL:
EXTERIOR WALLS, ROOF, WINDOWS, EXTERIOR DOORS, SLAB
EDGE U- VALUES UNKNOWN, NO WORK PROPOSED TO THESE
EXISTING COMPONENTS, NO UPGRADES REQUIRED PER WSEG
5EG 1130
HEAT SYSTEM: OTHER (HEAT PUMP) EXISTING SYSTEM TO
REMNAIN IN PLAGE
LEGAL DESCRIPTION
LEWIS G G -P G # 37 BEG N 81 -44 -15 E Igq.I1 FT FROM HUB AT
END OF CURVE ON GENT LN OF DUWAMISH- RENTON JUNCTION
RD 5D HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4
GOR BET SECS 14 4 15 -23 -4 TH N 4c1-24-00 W 2535 FT TH N
Oq -36 -00 E 52 FT TO TRUE BEG TH 5 82 -40 -30 E 510 FT
TH N 5q -22 -30 E 643.35 FT TH N 01 -51 -30 W 343 FT TO LEFT
BANK OF DUWAMISH RIVER BEING NLY BOUNDRY OF LEWIS D
G TH 5WLY ALG SD BANK OF RIVER TO PT N 00 -3q -40 W OF
TRUE BEG TH 5 00 -3q -40 E TO TRUE BEG ALSO POR OF D G
LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT
STRIP ADJ AND PARL TO ELY LN OF R/W OF P 5 ELEC GO
FOR JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE
INTERURBAN TRS
CONTACT INFORMATION
PROJECT CONTACT PERSON
TORJAN RONHOVDE, ARCHITECT
TORJAN@ RONHOVDEARCH I TECTS.COM
206 -858 -5500 S PARAIJ PERMIT
TENANT .... FOR:
HILL - ROM � - nanical
12604 INTERURBAN AVENUE SOUTH 4 C:
TUKWIULA, WA '18168 c`"c` �ca1
numbing
CONTACT: as Piping
JUDY STRONG C1ty of T F ` ;wila
(206) 244 -T120 - U _Dltt^ r ::';cioi'
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will
cnd may include adrequire i i new plan submittal
plan review fees.
INDEX OF DRAWINGS
ARCHITECTURAL:
G5 COVER SHEET, PROJECT NOTES, 51 T PLAN
AGI.I CODE REVIEW PLANS
AO.I OVERALL BUILDING PLAN
AI.I FLOOR PLAN AND SCHEDULES
AI .2 ENLARGED TOILET ROOM PLAN
AB.I CEILING AND LIGHTING PLAN
AII.I DETAILS
FI E COSY
Permit No.
PIP!, rrview approval is subistt to moors and omissions.
of construction documents does not authorize
3,fson of any adopted tole or ordinance. Receipt
L pioved Field Copy aiwi ; : *ifl . is acknowledged:
By
Date: x -Lo -- `Z2[2___
City Of lb a
BUILDING DIVISION
ACCESSIBILITY COMPLIANCE NOTES
I) THE PRIMARY BUILDING ENTRANCE 15 ACCESSIBLE.
2) ALL DOOR HARDWARE TO BE HG COMPLIANT PER ANSI A117.1
- 2003. UPGRADE ALL EXISTING DOORS TO LEVER HANDLES
IF NOT PRESENT.
3) CONSTRUCT (I) NEW ACCESSIBLE TOILET ROOM.
PROJECT INFORMATION
PARCEL NUMBER:
ZONE:
SCOPE OF WORK:
PROPERTY OWNER:
TYPE OF BUSINESS:
PROPOSED BUSINESS NAME:
CODE ANALYSIS:
OCCUPANCY CLASSIFICATION:
CHANGE OF USE:
TYPE OF CONSTRUCTION:
PROPERTY AREA:
GROSS BUILDING AREA:
TOTAL TENANT AREA:
OFFICE AREA:
NUMBER OF STORIES:
USE SEPARATION:
OCCUPANT LOAD FOR EGRET'S:
OCCUPANT LOAD FOR PLUMBING:
.r
EXISTING PARKING:
PARKING REQUIRED:
IMPERVIOUS AREA:
METHOD OF HEATING:
GOVERNING CODES:
PROJECT VALUATION:
0004800003
C /LI GOMMERGIAL /LIGHT
ADD APPROX. 220
NEW AGGE55IBLE TOILET
EXISTING OFFICE WAREHOUSE.
WILL BE INTERIOR WITH
A NEW WAREHOUSE
STAIR.
GATEWAY OLYMPIC
PO BOX 4q00 #201
SGOTSDALE, AZ 85261
MEDICAL BEDS STORAGE
DISTRIBUTION
HILL - ROM
SEE SHEET AGI.I
GROUP 5 -I STORAGE
OFFICE
NO (FORMERLY GROUP
3 -13 SPRINKLED (EXISTING)
465,2x5 5F (PER PGR)
72,000 5F
12,000 SF
I,gg2 5F (INCLUDING
NONE REQUIRED PER
(SEE SHEET AGI.I FOR
(SEE SHEET AGI.I FOR
21 STALLS AT BUILDING
HC VAN STALLS)
NO CHANGES PROPOSED
NO CHANGES PROPOSED
HEAT PUMP (OTHER/
HEAT SYSTEM IS EXISTING
CHANGES ARE PROPOSED
I. 2008 INTERNATIONAL
(IBC) WAG 51 -50
2.2008 INTERNATIONAL
CODE (IMG) WAG
3. 200q INTERNATIONAL
WAG 51 -54
4.2008 UNIFORM PLUMBING
WAG 5I -56, 5I -51
5.2008 WASHINGTON
CODE (WSEG) WAG
6.2003 I GG /ANSI
STANDARDS + WAG
10 AND II OF THE
$35,000
INDUSTRIAL
5F NEW OFFICE AND
ROOM TO AN
ALL WORK
THE EXCEPTION OF
LEVEL EXIT DOOR AND
INC
AND
AND GROUP B -
5 -I, B)
NEW AREA)
TABLE 508.4
CALCULATIONS)
CALCULATIONS)
(INCLUDING 2
NON - ELECTRIC)
- NO
BUILDING CODE
MECHANICAL
51 -52
FIRE CODE (IFC)
CODE (UPC)
STATE ENERGY
5I -II
AI 11.1 (ACCESSIBLE
A
51 -50 + CHAf- I tR
2008 IBC)
SEPARATE PERMITS
ELECTRICAL SYSTEM
PLUMBING SYSTEM
RACKING SYSTEM
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2012
A--5-- UV-.
City of Tukwila
BUILDING DIVISION
VICINITY MAP
�n.r .
tr
/N
i
a
u
k s IT::, At -
1
. C''
4 1, 4
Wm, 1444. L' �
* a
Pw 'a
-. —A "
4 411. 1F 4
a P
.:. ...„
3 4 , � y
?tOJtT'
LOCATION `. 6
L
• t a:v
4414.... r
d T v-t l44're
xx ' err
.C-
, i
im
..
HOVDE
ARCHITECTS
I4g00 INTERURBAN AVE SOUTH
SUITE I3S
TUKWILA, WASHINGTON 88168
(206) 851 -5500 I FAX (206) 851 -5501
ronhovdear_chi . ect om
imma
z
w
M
� Q
AVENUE SOUTH
0 INTERURBAN
Co
O
cz
co
va,
E°
cce=§0-
O
`.I
�V.
CITY R t� T!3 t.A
'MAY 2 3 2012
PERMIT CENTER
10
9
a
1
3
2
5 -22 -12
PERMIT SUBMITTAL
NO.
DATE
DESCRIPTION
REVISIONS
SHEET CONTENTS:
SITE PLAN
PROJECT NOTES
LEGAL DESCRIPTION
JOB NO.: HILL - ROM
DRAIA1N BY: LNIS
CHECKED BY: TS
DATE: 5 -22 -12
SHEET NO.
CS
GENERAL CODE AND EXITING NOTES
TENANT NET OFFICE AREA PER 502.1 = I,qq2 5F
OCCUPANCY SEPARATION: NONE REQUIRED
TOTAL REMODELED OFFICE AREA: I,qq2 5F/100 = 20 OCCUPANTS
I EXIT REQUIRED — 2 EXITS PROVIDED
TOTAL WAREHOUSE AREA: 10,005 5F/500 = 20 OCCUPANTS
I EXIT REQUIRED — 3 EXITS PROVIDED
WORST CASE TRAVEL DISTANCE: 7T -0' LF
WORST CASE COMMON PATH OF TRAVEL: 24' -0'
TOTAL OCCUPANT LOAD: 40
OFFICE DOOR WIDTH REVD PER 1005.1 : 20 OGO. x .2' = 4.0, (12' PROVIDED)
EXIT PROTECTION REQUIRED PER 1015.1.4: NO
EXIT SIGNAGE REVD PER 101111: YES
EXIT ILLUMINATION REQV PER 1006.1: ONLY WHEN BUILDING 15 OCCUPIED
EXIT ELY ILLUMINATION REVD PER 10063: YE5
NOTE: 11-ERE ARE NO CHANGES PROPOSED TO THE EXISTING EXITING SYSTEMS OR CONFIGURATION
TOILET ROOM CALC PER IBC TABLE 2902.1
WASHINGTON STATE AMENDMENTS, CHAPTER 2q
NOTE: THERE ARE 2 EXISTING SINGLE USER ADA COMPLIANT TOILET ROOMS SERVING THE EXISTING
OFFICE. THESE WILL BOTH BE RETAINED AS 15.
PLUMBItO OCCUPANT BASED ON 200 SF PER OFFICE PLUMBING OCCUPANT PLUS 5000 SF PER
WAREHOUSE PLUMBING OCCUPANT
I,qq2 5F / 200 = 12 PLUMBING OCCUPANTS, 6 MEN, 6 WOMEN
10,005 5F / 5000 = 2 PLUMBING OCCUPANTS, I MAN, I WOMAN
TOTAL PLUMBIC& OCCUPANTS = 14
REQUIRED TOILET ROOMS:
PER TABLE 2g02.I: UNDER 15 PLUMBING OCCUPANTS REQUIRES I ItIISEX TOILET ROOM.
PROVIDED TOILET ROOMS: 2 EXISTING, PLUS I NEW
DRINKING FOUNTAINS: 0 REQUIRED (I REQUIRED AT 30 —150 OCCUPANTS)
VENTILATION AND FRESH AIR REQUIREMENTS
ADDITIONAL VENTILATION AND FRESH AIR MAY BE REQUIRED, VIA MECHANICAL MEANS BASED ON
THE REQUIREMENTS OF THE STATE AMENDED 200q IMG CHAPTER 4
/
co
r
EX� / EXIT SEPARATION
DISGIIA ® DISTANCE = 35' -5'
REQUIRED = 1q' -3"
.N..NA'NX„
EXIT SEPARATION
DISTANCE = 131-6'
REQUIRED = 51' -5'
IIIIIIIIIIIIIIIllflllllllllllll
EMI*
r
WORST CASE TRAVEL DISTANCE
iv,
j■
L�J
00
00
CODE REVIEW PLAN
SCALE: I /4' =
fi NEW LIGHTED EXIT SIGN WITH
q0 MINUTE BATTERY
BACKUP
0 EXISTING LIGHTED EXIT SIGN
WITH q0 MIRJTE BATTERY
`BA.CKUP
2,210 5F NET
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2012
City of Tukwila
BUILDING DIVISION
THE
ON
HOVDE
TECTS
C.
14q00 INTERURBAN AVE SOUTH
SUITE 13S
TUKNILA, WASHINGTON 88168
(206) 851-5500 I FAX (206) 851 -5501
ronhovdearchit om
U
Z
U
11= Z
F: O
z �
Z < tiV PP 7 W ao p
a) En
Qgm"
> ass < >ss
_ a 3�
J ~o av
Z
=zw a�
w
M cc
� v EL
N
10
1
4
2 -2q —I2
PERMIT SUBMITTAL
NO.
DATE
DESCRIPTION
REVISIONS
SHEET CONTENTS:
CODE REVIEW RECEIVEU.
CITY OFT(1LA
MAY 2 3 2012
PERMIT CENTER
JOB NO.: 2012.06
DRAWN BY: LWS
CHECKED BY: TS
DATE: 2 -2q —I2
SHEET NO.
ACI.1
T H E
RONHOVDE
ARCHITECTS
L L C
14600 INTERURBAN AVE ` SOUTH
SUITE 13E5
TUKWILA, WASHINGTON cISI68
(206) 85q -5500 I FAX (20,- 859 -55OI
ronhovdearchi om
Itejor/i,fAr
7/Atir
JAN
STATE 0
RONHOVDE
WASHINGTON.
NOT A PART OF PROJECT
10
REVIEWED FOR
CODE COMPLIANCE
APPROVED
'JUN 0;1 2012
NO.
5 -22 -12
DATE
REVISIONS
PERMIT SUBMITTAL
DESCRIPTION
SHEET 'CONTENTS:
OVERALL BUILDM uIECV` LA
FLOOR PLAN MAY 2 3 2012
PERMIT CENTER
JOB NO.: HILL ROM
DRAWN BY: LH5
CHECKED BY: TJR
DATE:
5 -22 -12
SHEET NO.
A0.1
1
DOOR AND FRAME SCHEDULE
DOORS
FRAME
MARK
FINISH
NOMINAL. SIZE
DEPTH
FINISH
T H E
PONHOVDE
ARCHITECTS
L L C
I4gOO INTERURBAN AVE SOUTH
SUITE 13E5
TUKVN I LA, WASHINGTON S 168
(206) 859 -5500 I FAX (206) 85q -5501
ronhovdearchi ct
STAIN
3' -0'
T-0"
1 -3/4'
TIMELY
2,4,5,1,13,
STAIN
31 -0'
11-0'
-3/4'
TIMELY
4,11
PAINT
3'-0'
11 -0'
1 -3/4'
5, 12,
GENERAL DOOR NOTES
-ALL INTERIOR AND EXTERIOR DOORS NOTED SHALL HAVE LOCKS PROVIDED W/ HARDWARE THAT 15 READILY :OPENABLE FROM THE
EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE PER IBC IOOB.Lq
-ALL HARDWARE AILS, ,HANDLES, LOCKS, LATCHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR
TWISTING OF THE WRIST TO OPERATE PER IBG 1008.1.8.1
-ALL EXTERIOR DOORS TO BE EQUIPPED WITH THRESHOLDS WITH A MAXIMUM RISE OF 1/2' PER ANSI 4042.4.
-ALL DOORS IF NOT SPECIFICALLY NOTED OTHERWISE SHALL BE PROVIDED WITH HG LEVER HANDLE HARDWARE COMPLYING WITH ANSI
4042:6.
-ALL HARDWARE TO BE MOUNTED WITH OPERABLE PARTS LOCATE? BETWEEN 34' AND 48" ABOVE THE FLOOR PER ANSI 404.2.6.
-SEE SHEET AGI.I FOR LOCATIONS OF DOORS REQUIRED TO BE EQUIPPED WITH EXIT SIGNAGE AND EXIT ILLUMINATION.
-PANIC AND FIRE EXIT HARDWARE SHALL BE PROVIDED ON ALL DOORS NV LOCKS AND LATCHES PER IBC 1008.1:9.
-DOOR CLOSERS SHALL BE ADJ)STED 50 THAT FROM.. THE OPEN POSITION OF '10 DEGREES, THE TIME REGDRIED TO MOVE THE DOOR TO
AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MINIMUM
DOOR TYPES
1/2 LITE
TEMPERED
GLASS
NOTES:
1. EXISTING TO REMAIN
2 SAFETY GLAZING.
3. PANIC DEVICE
4. CLOSER
5. MATCH EXISTING OFFICE STANDARD DOORS
6. RELOCATE EXISTING DOOR
1. 6' JAMB AND HEAD, 36" HIGH LITE 1/2" MAX
8. THRESHOLD
9 DOORS LABELED 'El" ARE EXISTING MAIN EXIT DOORS. THEY
ARE EQUIPPED WITH PANIC DEVICES, DOOR CLOSERS, EXIT
SIGNAGE,1 /2' HIGH HG ACCESSIBLE THRESHOLDS. THEY ARE
PROVIDED WITH A LANDING ON EACH SIDE MEASURING AT
LEAST 48' X 48" WITH SLOPES NOT EXCEEDING 2% IN ANY
DIRECTION
10. ALUMINUM / GLASS ENTRANCE DOOR TO MATCH EXISTING
DOOR E3. REUSE EXISTING REMOVED ENTRANCE DOOR IF
POSSIBLE. INSTALL IN EXISTING HM FRAME.
II. ANSI F15 PASSAGE SET FUNCTION
12. TOILET ROOM DOORS TO BE PROVIDED WITH THUMB
ACTIVATED ANSI Fib PRIVACY LOCKSET.
13. LOCKSET ANSI F82 OFFICE LOCK PER OWNER
14. ` LEVER HANDLED LOCK SET, KEY OPERATED FROM ROOM
EXTERIOR ADD READILY DISTINGUISHABLE INDICATOR FOR
WHEN THE DOOR 15 LOCKED: PER ANSI E215I FUNCTION. ADD
SIGN ADJACENT TO POOR IN I" HIGH LETTERING STATING
"THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING 15
OCCUPIED."
15. REMOVE AND REPLACE EXISTING WOOD STOPPED SIDELITE
WITH NEW I' WIDE BY DOOR HEIGHT SIDELITE WITH FRAME TO
MATCH DOOR GLAZING TO BE TEMPERED SAFETY GLA55.
I6. MAX: U -VALUE b
FLAG NOTES
O ROUGH -IN FOR OWNER SUPPLIED. STAINLESS STEEL CABINET AND
SINK.
® 6 FT PLAM LOWER CABINET WITH SINK. 6 FT PLAM UPPER
CABINET W/ (2) ADJUSTABLE SHELVES.
03 FUTURE UPPER AND LOWER CABINETS.
O REMOVE EXISTING WINDOW. SAWGUT GONG. WALL BELOW WINDOW
TO FLOOR FOR INSTALLATION OF NEW 3' X 1' DOOR.
O: NEW STEEL AND CONCRETE PRE - MANUFACTURED LANDING AND
STAIR. SEE SHEET A2.I AND AII.I.
(1: \1
WALL TYPE LEGEND
NOTE: SEE AB:I FOR WALL TOP BRACING LOCATIONS AND AII.I FOR BRACING DETAILS.
EXISTING WALL - NO CHANGE PROPOSED
31/2 25 GA. 5Th. STUDS o 24' OC W/ 5/8' GWB ON BOTH SIDES. R -I3 BATT
INSULATION. MATCH HEIGHT OF ADJOINING WALLS. + - 12' -0' HIGH
3 1/2' 25 GA. 5TL. STUDS ®16' OG W/ 5/8 GWB ON BOTH SIDES. R -I3 BAIT'
INSULATION. MATCH HEIGHT OF ADJOINING WALLS. + - 10'-O' HIGH
6' 25 GA. 5TL. STUDS ® 16' OG Wl 518' GWB ON BOTH SIDES. R -I3 BATT
INSULATION. MATCH HEIGHT OF ADJOINING WALLS. + - 10'-O' HIGH
ROOM FINISH LEGEND
SEE CEILING PLAN ON A8.1 FOR CEILING HEIGHTS
FLOOR
E EXISTING TO REMAIN
GONG -I CONCRETE " SEALED
GONG -2 CONCRETE STAINED
5V SHEET VINYL
VCT VINYL COMPOSITION TILE
TILE TILE
CPT CARPET -
BASE
E
RB
COVE
TILE
WOOD,
EXISTING TO REMAIN
4' RUBBER BASE
6" SHEET VINYL (COVED)
4' TILE BASE
4" WOOD BASE
WALL5
GWB-1
PLAM
TILE
MR
FLOOR
BASE
WALLS
CEILING
EXISTING TO REMAIN
61^6 - PAINT COLOR PER TENANT
48 PLASTIC LAMINATE WAINSCOT AT ALL TOILET ROOM
WALLS WITH MOISTURE RESISTANT &NB THROUGHOUT AND 'PT'.
ABOVE
48' TILE AT WET WALLS * WITHIN 2 FT OF FIXTURES
MOISTURE RESISTANT FRP PANELS FULL HEIGHT
CEILINGS
E EXISTING TO REMAIN
ACT ACOUSTICAL CEILING TILE (SUSPENDED)
EXP EXPOSED STRUCTURE
GWB-I GWB PAINT COLOR PER TENANT
6YB-2 GWB - MOISTURE RESISTANT GM AND PAINT - COLOR PER TENANT
EXIST. OFFICES
12'
0
1
FILES
CPT
GWB-I
ACT
TOILET
5V
COVE
PLAN
G 1B-2
J
T -5'
3st
MAIN FLOOR PLAN
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2012
City of Tukwila
BUILDING DIVISION
RONHOVDE
ASHINGTON
coo
tee
co FE
VU
J
•gt
D
0
I
10
5- 22 -12.
PERMIT SUBMITTAL
NO.
DATE:
DESCRIPTION
REVISIONS
ICET CONTENTS:
FLOOR PLAN
SCHEDULES
CIIYTAN(VNlA
MAY 2.3 2012
PERMIT CENTER
JOB NO.: HILL - ROM
DRAWN BY: LW5
GI -IECKE P BY: T.IR
DATE: 5 -22 -12
SHEET NO.
Ati
ENLARGED TOILET ROOM PLAN
(6) T. e.' 11" $'-6"
STELL PICKET RAILING WITH 4'
MAXIMUM BETWEEN PIGKETS
ENLARGED EXTERIOR STAIR
TOILET ROOM FLAG NOTES
SEE AIIJ FOR ADDITIONAL INFORMATION. ALL REFERENCES TO ANSI
A117.1 -2003
60" DIA. TURNING RADIUS PER ANSI 304. KNEE, TOE AND DOOR OVERLAPS
PERMITTED PER 3043.1 AND 304.4.
30" X 48" SINK FLOOR SPACE PER ANSI 305.3
DOOR. WIDTH PLUS I8" X 60" PULL 5117E LATCH APPROACH CLEAR FLOOR SPACE
HC URINAL W/ RIM • 17" PER ANSI W53 d 30" X 18' FLOOR SPACE PER ANSI 3053
FLOOR MTD HG TOILET PER ANSI 604. LOCATE AT 18" FROM WALL "FRAMING OR
PARTITION PER W4.2
ALL SINKS TO COMFORM 1W HG. STANDARD ANSI 606 W/ FLOOR SPACE PER ANSI
3053
(16) WALL MTD. PAPER TOWEL DISPENSER
2' -O" X 3' -0" MIRROR MOUNT BOTTOM EDGE AT COUNTER BACKSPLASH
5' 0" X 3' 0° MIRROR MOUNT BOTTOM EDGE AT COUNTER BAGKTLASI I
T•LOOR DRAIN 2011 VLOOR 1" TO v IN
WALL HUNG HG SINK W/ RIM AT 34" PER 6063.
" uw
404 31
JIIIL VLL/ N.P t1M1VL IV I f7W I .VLVJ.
JI
HG TOILET GRAB BARS PER ANSI 604.5.1 AND 60452. INCLUDE NEW VERTICAL BAR
IN BOTH EXISTING TOILETS ROOMS.
60" X 56" NON - COMPARTMENT HG TOILET CLEARANCE SPACE PER ANSI '6043.1
30" X 48" SINGLE USER TOILET CLEAR GROUND SPACE PER ANSI 305.3 BEYOND
DOOR SWING.
21" SINK COUNTER MOUNT IN/ COUNTER AT 31" A.F.F. 2T' CLEAR KNEE SPACE.
24
INSULATE DRAIN LINES
48" PLAN. WAINSCOT - ALL SURFACES
6' INTEGRAL DOVE BASE. SEE FINISH SCHEDULE FOR MATERIAL.
36" X 60" PUSH SIDE LATCH APPROACH PER ANSI 40423.1
7d0" x 3/6" MIRROR, MOUNT BOTTOM EDGE ® COUNTER DAGKS LAGI I
THE SUBSTRATE OF ALL WALLS AND PARTITIONS WITHIN 2 FEET OF URINALS, HATER
CLOSETS AND SHOWERS SHALL BE HATER RESISTIVE .GINS "OR CEMENT BACKER
BOARD UP TO A HEIGHT OF 4 FT. HALLS AT SHOWERS 5I IALL EXTEND UP TO 7 FEET
f'ER IBC 10122.
60" X 36" ROLL IN I IC SHOI°CR. W/ 3 SIDED GRAB BAR AND HANDHELD FLEXIBLE
SHOWER MEAD
30° X CO" ROLL IN I IG SHOWER MIANUVERING SPACE.
21 EXISTING MOP SINK TO REMAIN
INSULATE
SUPPLY AND
DRAIN PIPES
PER ANSI 606:6
mfli,
COUNTER/SINK
5K
PER ANSI
q---
U—
MIRROR
SPOUT
[NEAR
----. ft 4' -I
CC)
x
X
z
PER ANSI 6063 DRINKING FOUNTAIN
D.F.
PER ANSI 606:3, W2.4, 3063
40"
,,� 42" MIN. BAR
nV
6063, d 306.3
IS"
24"
WG.
F.F.
PROVIDE 50LID
BLOCKING
(TYPICAL)
GRAB BAR TOILET PAPER DISP.
_613
PER ANSI 6045:I 1 60452 PER ANSI 604.7
AND ANSI 601
NOTES:
ALL ACCESSORIES SHALL
BE INSTALLED AND
SEALED TO PROTECT
STRUCTURAL MEMBERS
FROM MOISTURE
RIM
ELONGATED
BOWL
F.F.
TOWEL DISP
PTD
PER ANSI 606.1
HANDHELD
BSHOWER W/
ALE
z
n' S FOLD r-
SEAT —
SHOY9ER STALL
PER ANSI 605
AND ANSI 610
URINAL
U
PER ANSI 605
cn
F.F.
DISPENSERS/
RECEPTACLES
PER ANSI 6063
TOILET ROOM FIXTURE
MOUNTING HEIGHTS
SCALE 1/4' = I'-O" PER ANSI AII1.-2003
IHG -I
REVIEWED FOR
CODE COMPLIANCE
APPROVED
'JUN 01 2012
City ofTuk Tukwila
BUILDING DIVISION
T H E
RONHOVDE
ARCHITECTS
L L C
I4c100 INTERURBAN AVE SOUTH
SUITE 138
TUKINILA, 1NASHINGTON ISISS
(206) &51 -5500 I FAX (206) 551 -5501
ronhovdearchite s
5 -22 -12
PERMIT SUBMITTAL
:NO.
DATE
DESCRIPTION
REVISIONS
SHEET CONTENTS:
ENLARGED
TOIL$T�ALAN S
MAY 2 :1 2012
PERMIT CENTER
JOB NO.: HILL ROM
DRAWN BY: L15
CHECKED BY: TJR
DATE: 5 -22 -12
SHEET NO.
A2.1
2009 WASHINGTON STATE ENERGY
CODE (WSEC) SECTION 1513.1
LOCAL CONTROL AND ACCESSIBILITY:
EACH SPACE, ENCLOSED BY WALLS OR CEILING- HEIGHT PARTITIONS SHALL BE PROVIDED WITH
LIGHTING CONTROLS LOCATED WITHIN THAT SPACE. THE LIGHTING CONTROLS WHETHER ONE OR
MORE, SHALL BE CAPABLE OF TURNING OFF ALL LIGHTS WITHIN THE SPACE. THE CONTROLS SHALL
BE READILY ACCESSIBLE, AT THE POINT OF ENTRY/EXIT, TO PERSONNEL OGCUPYIN6'OR USING THE
SPACE. EXCEPTION: I) LIGHTING CONTROLS FOR SPACES WHICH MUST BE USED AS A WHOLE
[JUSTIFICATION MUST BE PROVIDED]; 2) AUTOMATIC CONTROLS; 3) CONTROLS REQUIRING TRAINED
OPERATORS; 4) CONTROLS FOR SAFETY HAZARDS AND SECURITY.
2009 WASHINGTON STATE ENERGY
CODE (WSEC) SECTION 1513.3
DAYLIGHT ZONE CONTROL:
ALL DAYLI&HTED ZONES, AS DEFINED IN CHAP ItR 2, BOTH UNDER OVERHEAD GLAZING AND
ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR
DAYLIGHT- OR OCCUPANT- SENSING AUTOMATIC CONTROLS, WHICH CONTROL THE LIGHTS
INDEPENDENT OF GENERAL AREA LIGHTING.
CONTIGUOUS DAYLIGHT ZONES ADJACENT TO VERTICAL ` GLAZING ARE ALLOWED TO BE
CONTROLLED BY A SINGLE CONTROLLING DEVICE PROVIDED THAT THEY DO NOT INCLUDE ZONES
FACING MORE THAN TWO ADJACENT CARDINAL ORIENTATIONS (I.E.`NORTH, EAST, SOUTH, WEST).
DAYLIGHT ZONES UNDER OVERHEAD GLAZING MORE THAN 15 FT. FROM THE PERIMETER SHALL BE
CONTROLLED SEPARATELY FROM DAYLIGHT ZONES ADJACENT TO VERTICAL GLAZING.
EXCEPTION: DAYLIGHT SPACES ENCLOSED BY WALLS OR CEILING HEIGHT PARTITIONS AND
GONTAINING 2 OR FEWER LIGHT FIXTURES ARE NOT REQUIRED TO HAVE A SEPARATE SWITCH FOR
GENERAL AREA LIGHTING.
2009 WASHINGTON STATE ENERGY CODE
(WSEC) SECTION 1513.6
AUTOMATIC SHUT -OFF CONTROLS, INTERIOR:
BUILDINGS GREATER THAN 5,000 5Q. FT. AND ALL SCHOOL CLASSROOMS SHALL BE EQUIPPED
WITH SEPERATE AUTOMATIC CONTROLS TO SHUT OFF THE LIGHTING DURING UNOCCUPIED HOURS.
WITHIN THESE BUILDINGS, ALL OFFICE AREAS LE55 THAN 300 5Q. FT. ENCLOSED BY WALLS OR
CEILING-HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, AND ALL SCHOOL
CLASSROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS THAT COMPLY WITH WSEC SECTION
1413.6.1 FOR OTHER SPACES, AUTOMATIC CONTROLS MAY BE AN OCCUPANCY SENSOR, TIME SWITCH
OR OTHER DEVICE CAPABLE OF AUTOMATICALLY SHUTTING OFF LIGHTING. EXCEPTIONS: I) AREAS
THAT MUST BE CONTINUOUSLY ILLUMINATED (EG., 24 -HOUR CONVENIENCE STORES), OR ILLUMINATED
IN A MANNER REQUIRING MANUAL OPERATION OF THE LIGHTING; 2) EMERGENCY LIGHTING SYSTEMS;
3) SWITCHING FOR INDUSTRIAL OR MANUFACTURING PROCESS FACILITIES AS MAY BE REQUIRED
FOR PRODUCTION; 4) HOSPITALS AND LABORATORY SPACES; 5) AREAS IN WHICH MEDICAL OR
DENTAL TASKS ARE PERFORMED ARE EXEMPT FROM THE OCCUPANCY SENSOR REQUIREMENT.
2009 WASHINGTON STATE ENERGY
CODE (WSEC) SECTION 1513.6.1
OCCUPANCY SENSORS:
OCCUPANCY SENSORS SHALL BE CAPABLE OF AUTOMATICALLY TURNING OFF ALL THE LIGHTS IN
AN AREA NO MORE THAN 30 MINUTES AFTER THE AREA HAS BEEN VACATED.` LIGHT FIXTURES
GONTROLLED BY OCCUPANCY SENSORS SHALL HAVE A WALL- MOUNTED, MANUAL SWITCH CAPABLE
OF TURNING OFF LIGHTS WHEN THE SPACE 15 OCCUPIED.
2009 WASHINGTON STATE ENERGY
CODE (WSEC) SECTION 1513.7
COMMISSIONING REQUIREMENTS:
FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC
CONTROLS, AUTOMATIC SHUT -OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME
SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,
COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN
ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL
BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS
AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE
PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN
ACCORDANCE WITH THIS PARAGRAPH.':
LIGHTING PLAN
SCALE: I/4N =
LIGHTING NOTES
LIGHTING ENERGY GALL.
PER MEG 200q EDITION SECTION' 1520
PERSGRIPTIVE LIGHTING OPTION
UNLIMITED LIGHTING FIXTURES PROPOSED
IE
LIGHT FIXTURES MUST COMPLY WITH ALL FOUR OF THE FOLLOWING CRITERIA:
I) ONE OR TWO LAMP (BUT NOT. THREE OR MORE LAMP);
2) LUMINAIRES HAVE A REFLECTOR OR LOUVER ASSEME3LY TO DIRECT THE 'LIGHT
(BARE LAMP STRIP OR INDUSTRIAL FIXTURES DO NOT COMPLY) - PARABOLIC
PROPOSED.
3) FITTED WITH TYPE T -I, T -2, T-4, T -5 T -8 OR GOMPAGT FLUORESCENT LAMPS FROM 5
TO 60 WATTS (BUT NOT T -IO OR T -I2 LAMPS) - T -8 LAMPS PROPOSED
4) HARD -WIRED FLUORESCENT ELECTRONIC DIMMING BALLASTS WITH PHOTOCELL OR
PROGRAMMABLE DIMMING CONTROL FOR ALL LAMPS IN ALL ZONES (NODIMMING
ELECTRONIC BALLASTS AND ELECTRONIC BALLASTS THAT SCREW INTO MEDIUM BASE
SOCKETS DO NOT COMPLY.
NOTE: TRACK LIGHTING 15 NOT ALLOWED UNDER THIS PATH.
ALLOWABLE; WATTAGE: UNLIMITED PER MEG SECTION 1520
ALL OTHER AREAS NOTED AS EXISTING WITH NO CHANGES PROPOSED TO LIGHTING
NEW 2 X 4 LAY -IN CEILING GRID MOUNTED
FLUORESCENT FIXTURE
RECESSED FLUORESCENT GAN LIGHT MOUNTED
IN GWB CEILING
LIGHTED EXIT SIGN WITH q0 MINUTE BATTERY
BACKUP
SOURCE SPECIFIC IOO CFM EXHAUST FAN
COMBINATION WITH LIGHT.
REVIEWED FOR
CODE COMPLIANCE
t • APPROVED
City of Tukwila
BUILDING DIVISION
•
T H E
RONHOVDE
ARCHITECTS
L L C
14q00 INTERURBAN AVE SOUTH
SUITE 138,
TUKINILA, INASHINGTON ci8I68
(206) 851 -5500 I FAX ( ib) 851 -5501
ronhovdearchite
10
5 -22 -12
PERMIT SUBMITTAL
NO.,
DATE
DESCRIPTION
REVISIONS
SHEET CONTENTS:
LIGHTING PLAN
RE EIVEIA
CITY OF TIJKIMLA
MAY 2.3 2012
PERMIT CENTER
JOB NO.: HILL - ROM
DRAWN BY: L145
CHECKED BY: TJ
DATE: 5 -22 -12
SHEET NO.
A8.1
16
,.
II' MIN. TREAD 3' MIN.
1/2' R NOSING
SEALED GONGRETE
FIIIFP STEEL PAN
?TSTEEL. STAIR
SJxALE ..a• - 1 -0
in
5' -0'
GLR`
— STEEL STRINGER
SEE STRUCTURAL
3M5 -I
BASE
SEE. WALL SCHEDULE
-1/4 RAM -SET GONG.
PINS @ 24" O.G.
GONG. FLOOR
WALL / FLOOR CONNECTION
SCALE 3' = I'-o"
2F5-q
5/8" GWB TYPE 'X'
3 1/2" METAL 511)05 W/ SPACING PER WALL TYPE SCHEDULE
R -I3 UNFAGED INSULATION
5 /8" 6WB TYPE 'X'
3 1/2' MTL STUD WALL
W/ BATT INSUL
NOT TO SCALE
3.5- METAL -BATT INSUL
5/8" GWB TYPE 'X'
3 I /2" METAL STUDS W/ SPACING PER WALL TYPE SCHEDULE
5/8" GWB TYPE 'X'
3 1/2' MTL STUD WALL
NOT TO SCALE
35- METAL -NO INSUL
$- -1 I/2' STANDARD PIPE
GUARDRAIL I HANDRAIL
— PRE -FAB GONG. PLATFORM
AND TREADS W/ METAL
PLATE RISERS
TYP. EXTERIOR STAIR
SCALE : 1/4" = I' -0"
XXXXXX -X
SPACER BAR, OR OTHER
SUITABLE SYSTEM, TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART.
2" MIN
BRAGINS
LOCATIONS:
I2' -O" QG AND 6-0"
MAX FROM FIXED
ADJACENT
PERIMETER WALLS
-MIN. 3/4" AT
UN- ATTACHED WALLS
ATTACH ONE END OF
GRID TO MOLDING
AT TWO ADJACENT
WALLS.
PERIMETER WIRES
OR APPROVED WALL
SUPPORT REQUIRED
AT THE TERMINAL
ENDS OF ALL GRID.
COMPRESSION POST
OPTIONS:
EMT CONDUIT:
/2" UP TO 6' -0"
3/4" UP TO S' -6"
I'" UP TO IO' -0"
METAL STUD 25
GAGE (I)
1 5/8" UP TO 6-2"
2 I /2" UP TO 10' -6"
3 1/2 UP TO I2' -6"
(2) 3 1/2" UP TO
15` -0'
IBC COMPLIANT
TYPICAL BRACING DETAIL
SCALE: I- I /2 " -1'-0"
PER GISGA ASSN.
VARIES
SEE WALL TYPE
5/8" G.W.B. EA. SIDE
METAL 51UD5
HOLLOW METAL FRAME
YV/ STEEL CASING
DOOR - SEE SCHEDULE
DOOR JAMB (HEAD SIMILAR)
SCALE 3" = I' -0"
1/4" GLASS (5
FOR SAFETY
REQUIREME
I /2 "xI -I/
31
IDMJ -I I_TI
8G5- 4_AGT_2
/2" TRIM
METAL STUDS
SEE WALL TYPES
INTERIOR WINDOW DETAIL
SCALE : 3" = I' -O
"T" INTERSEGTION
GYP. BD.
-GFMF
TYPICAL WALL INTERSECTION
SCALE : I" = i' -0"
3 -MS- INTERSECTION
5/8" 6WB TYPE 'X'
6" METAL STUDS W/ SPACING PER WALL TYPE SCHEDULE
/8 GWB TYPE 'X'
MTL STUD WALL
NOT TO SCALE
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2012.
City of Tukwila
6- METAL -NO IN1UILDING DIVISION
TYPICAL
SGALE I" = 1' -0 '
STUD
REINFORCING PLATE;
DIMENSIONS:
THICKNESS= MATCH STUD THICKNESS
HORIZONTAL= D - I/2'
VERTICAL (VERTICAL DIM. OF OPENING)
+D/2
12/4= CLEAR DIMENSION EACH SIDE
(r MIN. CLEAR DIM. FOR STUDS WHEN 'D'
15 LE55 THAN 4')
STUD PENETRATION
3 -M5 PENETRATION
METAL STUDS CONNECTED
TO ROOF STRUCTURE AT
8' -0" O.G. MAX.
SUPPORTS ATTACHED \ \
DIRECTLY TO TOP PLAT' \ \
OF NALL THROUGH \
OPENING IN 5AG \ \
45
METAL EDGE TRIM 1"
GONE. JOINT COMPOUND
5AG
TYPICAL
WALL
WALL / CEILING CONNECTION
SCALE '_ I -I/2" = I' -0"
SEISMIC BRACE
PER !B.G. AND
ASTM 635 AND
636
6,-0" M
N
AGOUST GAL
CEILING TILE
12' -0
MAX.
CEILING, BRACING PLAN
SCALE 1/4" = 1-0
865-4
WALL CONSTRUCTION PER PLAN
MIRROR, PER PLAN
24"
-PLAM OVER 3/4" PLYWD.
SEALANT
2x2 LEDGER:
ccm =
1x4 GONT.
Ix GUSSET, @ 24" 0.G.
HC SINK, COUNTER
SCALE : 3 - ILO"
3/4"
N
LL
II -HG SINK - COUNTER -I
METAL STUDS CONNECTED TO
STRUCTURE AT 8' -0" 0.G. MAX.
SUPPORTS ATTACHED
DIRECTLY TO TOP
PLATE OF WALL
NEW NALL ANGLE
WALL SEE SCHEDULE
45
ACT PER RGP
WALL / CEILING CONNECTION
scram : i -ia" _ 11-0..
865-3
T H E
RONHOVDE
ARCHITECTS
L L C
14q00 INTERURBAN AVE SOUTH
SUITE 138
TUKWILA, WASHINGTON ISI68
(206) S51-5500 I FAX (205) 858- 5501
ronhovdearchite- om
R -JA
STATE
RONHOVDE
WASHINGTON
0
CO
1
N
1
10
5 -22 -12
NO.
DATE
PERMIT SUBMITTAL
DESCRIPTION
REVISIONS
SHEET CONTENTS:
DETAILS
ci4EmR EIVEt.
f VI itA
MAY 2i 2012
PERMIT CENTER
JOB NO.: HILL ROM
DRAWN BY: LNI5
GHECKED BY: T.R
DATE: 5 -22 -12
SHEET NO.
Ai1.1