HomeMy WebLinkAboutPermit D12-174 - AT&T - BATTERY CABINETAT &T
16500 SOTJTHCENTER PY
EXPIRED 01-21-13
D12 -174
City oilkukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
DEVELOPMENT PERMIT
Parcel No.: 6437300010
Address: 16500 SOUTHCENTER PY TUKW
Suite No:
Project Name: AT &T
Permit Number: D12 -174
Issue Date: 07/25/2012
Permit Expires On: 01/21/2013
Owner:
Name: CHA SOUTHCENTER LLC
Address: 16500 SOUTHCENTER PKWY , SEATTLE WA 98188
Contact Person:
Name: SUNNY AUSINK
Address: 111S JACKSON ST, SUITE 200 , SEATTLE WA 98104
Contractor:
Name: WESTOWER COMMUNICATIONS INC
Address: 9961 SYDNEY HAYES RD , ORLANDO FL 32824
Contractor License No: WESTOCI975J8
Lender:
Name:
Address:
Phone: 206 - 446 -0448
Phone: 407 - 852 -1755
Expiration Date: 12/14/2012
DESCRIPTION OF WORK:
AT &T PROPOSES TO MODIFY EXISTING WIRELESS FACILITY LOCATED AT ABOVE REFERENCE BY ADDING (1) Te40
BATTERY CABINET TO EXISTING ROOFTOP.
Value of Construction: $10,000.00 Fees Collected: $464.52
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: N/A Occupancy per IBC: 0026
Electrical Service Provided by: PUGET SOUND ENERGY
* *continued on next page **
doc: IBC -7/10
D12 -174 Printed: 07 -25 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load:
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension: Private:
Water Meter:
N
Permit Center Authorized Signature:
ate:
Public:
Non - Profit: N
Public:
I hereby certify that I have read and examined t ref permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the
to this permit.
Signature:
Print Na
rforman of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
WJ tl%lim/U'
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Manufacturers installation instructions shall be available on the job site at the time of inspection.
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
doc: IBC -7/10
012 -174 Printed: 07 -25 -2012
any violation of any of the provisions of the ing code or of any other ordinances of the of Tukwila. Permits
presuming to give authority to violate or ca he provisions of the code or other ordinanc the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7110
D12 -174 Printed: 07 -25 -2012
t•
•
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www.TukwilaWA.gov
Building Permit No. 1. -.' 71
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 6437300020
Site Address: 16500 Southcenter Pkwy, Tukwila, WA Suite Number: Floor:
Tenant Name: AT &T MOBILITY (WA094)
PROPERTY OWNER
Name: CHA SOUTHCENTER LLC
Address: 16500 SOUTHCENTER PKWY
City: TUKWILA State: WA Zip: 98188
CONTACT PERSON — person receiving all project
communication
Company Name: WESTOWER COMMUNICATIONS
Name: SUNNY AUSINK
City: ORLANDO State: FL Zip: 32824
Address: 111 S. JACKSON ST. #200
Contr Reg No.: WESTOCI975J8 Exp Date: 12/14/2012
City: SEATTLE State: WA Zip: 98
104
Phone: (206) 446 -0448 Fax: (206) 903 -8513
Email: SAUSINK @PTSWA.COM
GENERAL CONTRACTOR INFORMATION
Company Name: WESTOWER COMMUNICATIONS
Address: 9961 SIDNEY HAYES ROAD
City: ORLANDO State: FL Zip: 32824
Phone: Fax:
Contr Reg No.: WESTOCI975J8 Exp Date: 12/14/2012
Tukwila Business License No.:
H:Wpplications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx
Revised: August 2011
bh
New Tenant: ❑ Yes ® ..No
ARCHITECT OF RECORD
Company Name: CORNERSTONE ENGINEERING
Architect Name: JONATHAN D. GIBSON
Address: 16928 WOODINVILLE - REDMOND RD N]
City: WOODINVILLE State: WA Zip: 98072
Phone: (425) 487 -1732 Fax: (425) 487 -1734
Email:
ENGINEER OF RECORD
Company Name: CORNERSTONE ENGINEERING
Engineer Name: JONATHAN D. GIBSON
Address: 16928 WOODINVILLE - REDMOND RD NI
City: WOODINVILLE State: WA Zip: 98072
Phone: (425) 487 -1732 Fax: (425) 487 -1734
Email:
LENDER/BOND ISSUED. (required for projects $5,000 or
greater per RCW 19.27.095)
Name: NOT APPLICABLE
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION — 206 -431 -3670
Valuation of Project (contractor's bid price): $ 10,000
Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
AT &T PROPOSES TO MODIFY EXISTING WIRELESS FACILITY LOCATED AT ABOVE REFERENCE ABOVE BY
ADDING (1) Te40 BATTERY CABINET TO EXISTING ROOFTOP.
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes I No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:'Applications \Forms - Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -1 I.docx
Revised: August 201 I
bh
Page 2 of 4
Existing; ,
Interior'Rerimodel:
Addition to `
Existing
Structure ,
NeW .
, Type of
Construction per
IBC„ _
: Type of
`- Occupancy per.
IBC .
In Floor
2nd Floor •
3'd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck .
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes I No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:'Applications \Forms - Applications On Line \2011 Applications\Permit Application Revised - 8 -9 -1 I.docx
Revised: August 201 I
bh
Page 2 of 4
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR UTHORI . D A N
Signature:
Print Name:
SUNNY AUSIN
Mailing Address: 111 S. JACKSON ST. #200
H:Wpphcauons\Forms- Apphcanons On Line \2011 Apphcat ons\Perma Appltcauon Revised - 8- 9- 11.docx
Revised: August 2011
bh
Date: 05/22/2012
Day Telephone: (206) 446 -0448
SEATTLE WA 98104
City State Zip
Page 4 of 4
1
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 6437300010
Address: 16500 SOUTHCENTER PY TUKW
Suite No:
Applicant: AT &T
RECEIPT
Permit Number: 1)12-174
Status: APPROVED
Applied Date: 05/23/2012
Issue Date:
Receipt No.:
R12 -02195 Payment Amount: $283.30
Initials: TLS
User ID: 1670
Payment Date: 07/25/2012 01:59 PM
Balance: $0.00
Payee: HEATHER H WASNICK
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. O2243C
ACCOUNT ITEM LIST:
Description
283.30
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100
640.237.114
Total: $283.30
278.80
4.50
DCD— PW— PERMIT CTR
6300 SOUTHCENTER BLUD
TUKWILA, WA 98188
TERMINAL ID. : 02845883
MERCHANT R: 362313263885
UI SA CIK. 1670
$$$$$$$$$$$$4169 t
SALE
BATCH: 080381 INVOICE 5543102139
DATE: Jul 25, 12 TIME: 13:57
SEO :0803 AUTH:02243C
TOTAL
$283.30
ACCORDING100PCARD ISSUERTAGREEMENT
MERCHANT AGREEMENT IF CREDIT VOUCHER
MERCHANT COPY
II •
w4s City of Tukwila
ti Department of Community Development
6. A
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 6437300010
Address: 16500 SOUTHCENTER PY TUKW
Suite No:
Applicant: AT &T
RECEIPT
Permit Number: D12 -174
Status: PENDING
Applied Date: 05/23/2012
Issue Date:
Receipt No.: R12 -01669
Initials:
User ID:
WER
1655
Payment Amount: $181.22
Payment Date: 05/23/2012 02:37 PM
Balance: $283.30
Payee: WESTOWER COMMUNICATIONS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 117429 181.22
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 181.22
Total: $181.22
doc: Receiot -06 Printed: 05 -23 -2012
mil,. COFF- ,NERS"1rONE
ENGINEERING, INC.
CIVIL ♦ SJRUCILIRAL ♦ SURVEY
16928 Woodinville- Redmond Rd NE, Suite 210
Woodinville, WA 98072
Email: cei @cornerstone - engr.com
Web: www.cornerstone- engr.com
FILE C ! PY
por1t No.
Structural Calculations
Prepared By:
Checked By:
Prepared Date:
CEI Project No.:
For
Battery Cabinet Installation
at &t
Site Name: Tukwila
Site Number: WA094
16500 Southcenter Parkway
Tukwila, WA 98188
King County
John M. Ricardi, E.I.T.
Jonathan D. Gibson, P.E.
May 7, 2012
12 -13054
Phone: (425) 487 -1732
(206) 250-7306
Fax: (425) 487 -1734
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 2 3 2012
PERMIT CENTER
t)12- RAI
lams emu WI3
Comprehensive Design Solutions for Your Project Success!
1 Project: WA094 Tukwila Date: May 7, 2012
Client: AT &T Prepared By: J. Ricardi
CEI No.: 12 -13054 Page
I. Project Description
The existing AT &T telecommunications site is located atop the building at 16500 Southcenter Parkway in the city
of Tukwila, King County, Washington. The site currently consists of (2) NOKIA cabinets, (1) TE43 Auxiliary
cabinet, (1) UMTS cabinet, (2) TE40 Battery Cabinets, and (1) TE21 power cabinet located on and supported by
the existing rooftop platform beams.
The structural design and analysis for the AT &T battery cabinet installation includes the addition of (1) TE40
cabinets. The additional equipment is to be installed on the existing rooftop platform beams. The equipment and
platform loads transfer directly to the load bearing columns of the building. All the loads then transfer from the
load bearing columns of the building into the foundation and to the soil.
II. Design Procedure
The information in this report summarizes the requirements for construction of structural elements for the
proposed design in conformance with the 2009 International Building Code (2009 IBC). Unless noted otherwise,
all means and methods used shall be in keeping with good and generally accepted construction practices and all
prescriptive design requirements of the 2009 IBC.
The proposed additional loading has had a structural stability evaluation in accordance with structural code
compliance. This analysis derives its applied loads from minimum 85 mph basic wind speed (3- second gust),
Exposure "B ". Since soil properties are not available, seismic site class "D" were conservatively used for this
analysis per 2009 International Building Code (Section 16).
III. Conclusions and Recommendations
The existing rooftop platform beams are structurally adequate to support the proposed loading of the additional
battery cabinets with the addition of the (2) steel L4x4x1 /4 below each proposed cabinet provided for positive
anchorage. Please refer to the following structural calculations and supporting drawings for the equipment cabinet
addition.
General Contractor shall verify all existing dimensions, member sizes and conditions prior to commencing any
work. All dimensions of existing condition shown on the calculation are intended as guidelines only and must be
verified in field. Any discrepancies shall be called to the attention of the architect or engineer and shall be
resolved before proceeding with the work. Contractor shall provide temporary bracing for the structure and
structural components until all final connections have been completed in accordance with the plans.
IV. Design Criteria
The design and analysis is based on the following site specific conditions:
1. Occupancy Catergory: II (Standard Occupancy)
2. Seismic:
Ss = 1.423g, S1 = 0.487g,
Sps = 0.949g, Sp, = 0.491g
I = 1.0, Site Class = "D ", Seismic Design Category= "D"
3. Wind: Wind Speed = 85 mph, Ir„ = 1.0, Exposure: "B"
Topographic Factor, Kn = 1.00
16928 Woodinville- Redmond Rd NE, Suite 210
Woodinville, WA 98072
Email: cei @cornerstone - engr.com
Web: www.cornerstone- engr.com
CORNERS-TONE
ENGINEERING INC.
Phone: (425) 487 -1732
(206) 250 -7306
Fax: (425) 487 -1734
i Project: WA094 Tukwila Date: May 7, 2012
Client: AT &T Prepared By: J. Ricardi
CEI No.: 12 -13054 Page 2
Seismic Design Parameters
Conterminous 48 States
2009 International Building Code
Latitude = 47.454563
Longitude = - 122.26292400000001
Spectral Response Accelerations Ss and S1
Ss and S1 = Mapped Spectral Acceleration Values
Site Class B - Fa = 1.0 ,Fv = 1.0
Data are based on a 0.05 deg grid spacing
Period Sa
(sec) (g)
0.2 1.423 (Ss, Site Class B)
1.0 0.487 (S1, Site Class B)
Conterminous 48 States
2009 International Building Code
Latitude = 47.454563
Longitude = - 122.26292400000001
Spectral Response Accelerations SMs and SM1
SMs =FaxSs and SM1 =FvxS1
Site Class D - Fa = 1.0 ,Fv = 1.513
Period Sa
(sec) (g)
0.2 1.423 (SMs, Site Class D)
1.0 0.737 (SM1, Site Class D)
Conterminous 48 States
2009 International Building Code
Latitude = 47.454563
Longitude = - 122.26292400000001
Design Spectral Response Accelerations SDs and SD1
SDs = 2/3 x SMs and SD1 = 2/3 x SM1
Site Class D - Fa = 1.0 ,Fv = 1.513
Period Sa
(sec) (g)
0.2 0.949 (SDs, Site Class D)
1.0 0.491 (SD1, Site Class D)
16928 Woodinville- Redmond Rd NE, Suite 210
Woodinville, WA 98072
Email: cei@comerstone-engr.com
Web: www.cornerstone- engr.com
CORNERSIr'ONE
E N G I N E E R I N G , I N C.
Phone: (425) 487 -1732
(206) 250-7306
Fax: (425) 487 -1734
Site Name: WA094 TUKWILA
Date: 05/07/12
Client: AT &T
CEI No.: 12 -13054
By: JMR
Page:
Subject: Lateral Design Calculation
Seismic Load Calculation for Components and System
(Reference: IBC 2009, Sec. 1613 & ASCE 7 -05, Ch. 13, USGS Earthquake Ground Motion Parameters v5.0.9a)
Design Seismic Force:
0.2s Spectral Response Acceleration, Site Class B, Ss
1.0s Spectral Response Acceleration, Site Class B, Si
Site Class
Occupancy Category = �1F:Ilti "'.�Itli .jai {_�+3�ir,y laulktu'�C
Site Coefficient per Ss & Site Class, Fa
Site Coefficient per Si & Site Class, F„
SMS = FaSs
SM, = FvS,
SDs = 2/3 SMs
S01 = 2/3 SM,
Seismic Design Category per SDs
(Per ASCE 7 -05, Chapter 13)
Component amplification factor, ap
Component Importance factor, Ip
Component operating weight, Wp
Component response modification factor, Rp
Height in structure at point of attachment of component, z
Average roof height of structure, h
() 0
1.000
1.513
1.423
0.737
(IBC 09, Figure 1613.5(1))
(IBC 09, Figure 1613.5(2))
(IBC 09, Table 1613.5.2)
(IBC 09, Table 1604.5)
(IBC 09 Table 1613.5.3(1))
(IBC 09 Table 1613.5.3(2))
(IBC 09, Eq 16 -36)
(IBC 09, Eq 16 -37)
0.949 (IBC 09, Eq 16 -38)
0.491 (IBC 09, Eq 16 -39)
= D
Seismic Design Force, Fp
Max. Seismic Design Force, Fp, max
Min. Seismic Design Force, Fp. min
Min. swismic design force,
Max. seismic design force,
Seismic Design Force,
Fp, min =
Fp, max =
Fp
0.7Fp =
1 (1
iOO
Wp
100
100
(ASCE 7 -05, Table 13.6 -1)
(ASCE 7 -05, Section 13.1.3)
Ib
(ASCE 7 -05, Table 13.6 -1)
ft
ft
0.4apSnsWF,
Rp/li (1 +2zJh)
1.6SDSIpWF
0.3SDSIpWn
0.28
1.52
WF, (Ib)
Wp (Ib)
(Eq. 13.3 -1)
(Eq. 13.3 -2)
(Eq. 13.3 -3)
(Strength Design)
(ASD)
6928 Woodinville- Redmond Rd NE, #210
Woodinville, WA 98072
E-mail: cei @cornerstone - engr.com
Web: www.cornerstone- engr.com
TeL (425) 487 -1732
(206) 250 -7306
Fax: (425) 487 -1734
Site Name: WA094 TUKWILA
Client: AT &T
By: JMR
Date: 05/07/12
CEI No.: 12 -13054
Page:
Subject: Lateral Design Calculation
Wind Load Calculation for Other Structure
(Reference: IBC 2009, Section 1609 & ASCE 7 -05, Chapter 6)
Wind Velocity Pressure:
Basic Wind Speed, Vas (mph)
Exposure Category
Occupancy Category
Wind Load Importance Factor, IW
Velocity pressure exposure coefficient, K,
Topographic Factor, K2,
Wind Directionality Factor, Kd
Velocity Pressure, q,
Design Wind Force: For Open Structures & Equipment
Gust effect factor, G
Net force coefficient, Cf
On building rooftop w/ h <60ft, fr
Projected area normal to the wind, Af
Design Wind Force, F.„„
F
1.6F
Height
z, (ft)
Exposure B (K,)
Case 1 ' Case 2
0 -15
0.70
0.57
20
0.70
0.62
25
0.70
',
0.66
30
0.70
0.70
40
0.76
0.76
50
0.81
0.81
60
0.85
0.85
70
0.89
'
0.89
80
0.93
0.93
90
0.96
0.96
100
0.99
0.99
120
1.04
1.04
140
1.09
1.09
160
1.13
1.13
180
1.17
1.17
200
1.20
1.20
(ASCE 7 -05, Figure 6 -1)
(ASCE 7 -05, Section 6.5.6)
(IBC 09, Table 1604.5)
(ASCE 7 -05, Table 6 -1)
(ASCE 7 -05, Table 6 -3)
(ASCE 7 -05, Figure 6 -4)
(ASCE 7 -05, Table 6 -4)
0.00256K,K,tKdV2IW (ASCE 7 -05, Eq. 6 -15)
16.48 psf (ASCE 7 -05, Section 6.5.10)
(ASCE 7 -05, Section 6.5.8)
(ASCE 7 -05, Figure 6- 20 -23)
(ASCE 7 -05, Section 6.5.15.1)
ft'
frq,GC,A, lb
Velocity Pressure (q,)
Case 1 Case 2
11.65
11.65
11.65
11.65
12.65
13.48
14.15
14.82
15.48
15.98
16.48
17.31
18.14
18.81
19.48
19.98
9.49
10.32
10.99
11.65
12.65
13.48
14.15
14.82
15.48
15.98
16.48
17.31
18.14
18.81
19.48
19.98
(ASCE 7 -05, Section 6.5.15)
(ASD)
(Strength Design)
16928 Woodinville- Redmond Rd NE, #210
Woodinville., WA 98072
F -mail: cei @cornerstone- engr.com
Web: www.cornerstone- engr.com
Tel' (425) 487 -1732
(206) 250- 7306
Fax: (425) 487 -1734
??roject: WA094 Tukwila Date: May 7, 2012
Client: AT &T Prepared By: J. Ricardi
CEI No.: 12 -13054 Page S
Analysis of Additional
Battery Cabinet
16928 Woodinville - Redmond Rd NE, Suite 210
Woodinville, WA 98072
Email: cei @comerstone- engr.com
Web: www.cornerstone- engr.com
CORNERS-II-ONE
E N G I N E E R I N G , I N C.
Phone: (425) 487 -1732
(206) 250-7306
Fax: (425) 487 -1734
Specifications for Argus' Te40 Outdoor Battery Enclosure
Electrical
Input Voltage:
Feeder Breaker:
Mechanical
Dimensions:
Weight:
Mounting:
HVAC:
Enclosure:
Environmental
Operating Temperature:
Storage Temperature:
Humidity:
Elevation:
Weather Tightness:
Regulatory Approvals
Enclosure Ratings:
Telcordia:
Product Safety:
120Vac, 60Hz single phase (for air conditioner)
15A recommended
2134mm H x 762mm W x 762mm D
(84" H x 30" W x 30" D)
1451 kg (3200 lb.) fully loaded with batteries
Pad or platform
Air conditioner with built -in heater
Aluminum, 5052 -H32
-40 to +46 °C
(-40 to 115 °F)
-40 to +85 °C
(-40 to +185 °F)
0 to 95% non - condensing
-50 to 4000 meters operating
( -164 to 13,123 feet)
NEMA Type 3R
CSA/UL Type 3R
IEC enclosure designation IP56
See also Environmental (above)
Designed to GR-487
CSA/UL 60950
The above information is valid at the time of publication. Consult factory for up -to -date ordering information.
Specfcatlons are subject to change without notice.
Argus Technologies Ltd. 029 - 030-01 Rev B WC
Printed In Canada. ® 2009 Argus Technologies Ltd. ARGUS is a registered trademark of Argus Technologies Ltd. All Rights Reserved.
291.2 [11.46]
CONCRETE PAD OR PLATFORM MOUNTING
(USE THESE HOLES FOR SEISMIC)
1515.9 [0.63] 4 PLACES
CONCRETE PAD MOUNTING:
DRILL AND INSTALL CONCRETE ANCHOR BOLTS,
USE HILT' HSLB- M12/25 (ARGUS P/N 633- 066 -10) OR EQUIVALENT
PLATFORM MOUNTING:
USE APPROPRIATE MOUNTING HARDWARE
762:0.[30.00]
693.2 [27.29]
1053.2 [41.46]
DOOR OPEN
61.0 [ 2.40]
BASE LAYOUT (TOP VIEW
762.0 [30.00]
ENCLOSURE
DIMENSION
706.1 [27.80]
27.9 [1.10]
640.1 [25.20]
61.0 [2.40]
165.1 [6.50]
431.8 [ 17.00]
27.9 [ 1.10]
762.0 [30.00]
ENCLOSURE
DIMENSION
291.5 [11.47]
165.1 [6.50]
ARGUS
FRONTs'r;M.s
Ma_ : I5,e.
ml
•,os ses• sole NTS
0 14
mac:
OUTLINE DRAWING,
PWR SYS,BATTERY
ENCLOSURE,Te40
MET 2 C.T 2
-101-06
P/A
Mik .AeaueTECH»i.oa1Ea
E.2CDRNEFSrDNE
E N G I N E E R I N G, 1 N C.
Site Name: WA094 TUKWILA
Date: 05/07/12
Client: AT&T
CEI No.: 12 -13054
By: JMR
Page:
Subject: Lateral Design Calculation
Determine Anchorage Reactions from Wind Load
(Reference: 2009 IBC, Section 1609 & ASCE 7 -05, Chapter 6)
Load Combination (ASCE 7 -05, Section 2.3)
1 1.4D
2 1.2D
3 1.2D + 0.8W
4 1.2D + 1.6W
5 1.2D + 1.0E
6 0.9D + 1.6W
7 0.9D + 1.0E
Argus Te40 Battery Cabinet Specifications:
height of cabinet, h =
width of cabinet, w =
dist. between bolts, d =
84 in
30 in
25.2 in
Design Parameter
D = Equipment Weight (Wp)
Af = 17.5
IW = 1.00
Vas = 85
Exposure = B
kZ = 0.99
kd = 0.90
kn = 1.0
qZ = 0.00256 *kz *kd *kr *V3s *Iw = 16.48 psf
G = 0.85
Cf 1.30
FW = qZ *G *Cf *Af = 318.7 lbs
Cabinet Specifications
Argus Te40 Battery Cabinet (Empty)
Equipment Weight (Wp) =
h/2 =
d=
Argus Te40 Battery Cabinet (Full)
Equipment Weight (Wp) =
h/2 =
d=
800 lbs
42.0 in
25.2 in
3200 lbs
42.0 in
25.2 in
(ASCE 7 -05, Table 6 -1)
(ASCE 7 -05, Fig. 6 -1)
(ASCE 7 -05, Table 6 -3)
(ASCE 7 -05, Table 6 -4)
(ASCE 7 -05, Fig. 6 -4)
(ASCE 7 -05, Eqn. 6 -15)
(ASCE 7 -05, 6.5.8.1)
(ASCE 7 -05, Fig. 6 -21)
(ASCE 7 -05, Eqn. 6 -28)
16928 Woodinville- Redmond Rd NE, #210
Woodinville, WA 98072
E -mail: cei @cornerstone - engr.com
Web: www.cornerstone- engr.com
Tel: (425) 487 -1732
(206) 250 -7306
Fax: (425) 487 -1734
ECOFNEFEflrOfJE ENGINEERING, INC.
Site Name: WA094 TUKWILA
Client: AT &T
CEI No.: 12 -13054
By: JMR
Page: q
Subject: Lateral Design Calculation
Anchorage Reactions
Argus Te40 Battery Cabinet (Empty)
V„=
1.6Fw
T„ =
T„ =
4 bolts
h /2x1.6Fw- d/2x[1.20]
d x 2 bolts
h/2x1.6Fw- d /2x[0.9D]
d x 2 bolts
Argus Te40 Battery Cabinet (Full)
V� _
1.6Fw
T„ =
T„ =
4 bolts
h/2 x1.6Fw - d /2x[1.2D]
d x 2 bolts
h/2 x1.6Fw - d /2x[0.9D]
d x 2 bolts
w
d
V
SIDE
WIND
0.13 kips
0.18 kips
0.24 kips
0.13 kips
-0.54 kips
-0.30 kips
w
FRONT
16928 Woodinville- Redmond Rd NE, #210
Woodinville, WA 98072
E -mail: cei @cornerstone - engr.com
Web: www.cornerstone - engr.com
Tel: (425) 487 -1732
(206) 250-7306
Fax: (425) 487 -1734
}
ECOPLNEFLS1rONE ENGINEERING, INC.
Site Name: WA094 TUKWILA Date: 05/07/12
Client: AT&T
CEI No.: 12 -13054
By: JMR
Page: 10 1
Subject: Lateral Design Calculation
Determine Anchorage Reactions from Seismic Load
(Reference: 2009 IBC, Section 1613 & ASCE 7 -05, Section 2,12,13)
Load Combination (ASCE 7 -05, Section 2.3)
1 1.4D
2 1.2D
3 1.2D + 0.8W
4 1.2D + 1.6W
5 1.2D + 1.0E
6 0.9D + 1.6W
7 0.9D + 1.0E
Argus Te40 Battery Cabinet Specifications:
height of cabinet, h = 84 in
width of cabinet, w = 30 in
dist. between bolts, d = 25.2 in
Design Parameter
D = Equipment Weight (Wp)
L = N/A
W N/A
E1 = PQE + 0.2SosD [ASCE 7 -05, Eq.12.4 -1]
E2 = pQE - 0.2SDsD [ASCE 7 -02, Eq.12.4 -2]
P = 1.0
QE, Fp = 0.45 Wp
SIDS = 0.947 g
Cabinet Specifications & Seismic Loads
Argus Te40 Battery Cabinet (Empty)
Equipment Weight (Wp) =
Fp =pQE =
0.2SDsD =
h/2 =
d=
Argus Te40 Battery Cabinet (Full)
Equipment Weight w/ fuel (Wp) =
Fp =pQE=
0.2SDsD =
W2 =
d=
800 Ibs
363.8 lbs
151.6 Ibs
42.0 in
25.2 in
3200 Ibs
1455.1 lbs
606.3 Ibs
42.0 in
25.2 in
16928 Woodinville- Redmond Rd NE, #210
Woodinville, WA 98072
E -mail: cei @cornerstone - engr.com
Web: www.cornerstone - engr.com
Tel: (206) 250 -7306
(425) 487 -1732
Fax: (425) 487 -1734
}
EIIICOFNEREI1rONE
E N G I N E E R I N G, I N C.
Site Name: WA094 TUKWILA
Client: AT &T
CEI No.: 12 -13054
By: JMR
Subject: Lateral Design Calculation
Page: t % 1
Anchorage Reactions
Argus Te40 Battery Cabinet (Empty)
1.0p QE
V„ = 1.3 4 bolts
T„= 1.3
h /2x1.0p QE +d /2x[1.0(0.2SpsD) -1.2D]
T„= 1.3
h/2 x1.0p QE +d /2x[1.0(0.2SDSD) -0.9D]
d x 2 bolts
Argus Te40 Battery Cabinet (Full)
1.0pQE
V" = 1.3 4 bolts
T„= 1.3
T„ = 1.3
d x 2 bolts
h/2 x 1.0p QE +d /2x[ 1.0(0.
d x 2 bolts
h/2 x 1.0p QE +d /2x[1.0(0.
2SDSD) -1.2D]
2SDSD) -0.9D]
d x 2 bolts
+1- 0.2SDSW
d
SIDE
C
SEISMIC
0.12 kips
0.13 kips
0.21 kips
0.47 kips
0.53 kips
0.84 kips
11
w
FRONT
16928 Woodinville- Redmond Rd NE, #210
Woodinville, WA 98072
E -mail: cei @cornerstone - engr.com
Web: www.cornerstone - engr.com
Tel: (206) 250 -7306
(425) 487 -1732
Fax: (425) 487 -1734
ECORNEFS1rDNE
E N G I N E E R I N G , I N C.
project \n) A 0qW Ti
location TU
client Ael 4. -
by zMK
date 7M / I Z
checked
date
sheet no.
tiz
CEI job no.
12- }3caS9
ZOLS
x-1'70 Zol...7
\L\b 1 601_'1
"TM (Lt) '12. .c1) K30'1
SHcRR•• 6
s (041,)?-
Z
•
7E45 -11 cis F� = 3$1z
33. %K(;nZ
_ 01133 <10 ok
U S t (,1) t (7:96 i(511 L7 S To P0)JcNA0V.
C�az�a GAT �RazN � io L 1 vs. SU >a<7 ECM,
ECDFRNERB1rONE
E N G I N E E R I N G , I N C.
project
by
location
date
sheet no.
1.3
client
checked
date
CEI job no.
EQucL?Nk w.1 S ?owT ES-1.61\)
•- i 1. %.1-\ x'Iw (■3)R5N c
(..)-2.°6\t'17-‘5) �z>
/
Mh t
13%LA 3 4.
LOADS
7E yo = 3Zbb1
COI\NEC- TLOm U ai.bN .
TR`I s"")(;' R3o1
• N1/41-
�T we Z� . 0,:30
t,L R-z. l 1.1 Le /0.0, ;:,-L
r"v Ir6 Ksk
6:ZSy;C l 0
1.-1 -W -) (4 5 P.POZ -' bE '\ Wi27H s�$�
30� aoLTS T ' Po tM N i' t ..1j T-t) FI NV6E
13
-,..A.11\5 To S'
JO CZ Oct N "V C.- 1.)E. i
,Steel ceam;,;.,r
Lic. # : KW- 06006053
Description :
L4x4x1/4
Material Properties.
File: ZADat 1Storage1ComerstonelEngmeennnngV +Tq;201311213054 "1,094 Tukwila BAT1Calcsltukwiila bat ec6
t.�.,ENERCALCcINC, 1983= 2011LBuild •6_:1212.7NVer61127,1 :.
Licensee : CORNERTSTONE ENGINEERING INC.
Calculations per AISC 360-05, IBC 2006, CBC 2007, ASCE 7.05
Analysis Method : Load Resistance Factor Design
Beam Bracing : Completely Unbraced
Bending Axis : Major Axis Bending
Load Combination 2006 IBC & ASCE 7 -05
Fy : Steel Yield : 36.0 ksi
E: Modulus : 29,000.0 ksi
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Load for Span Number 1
Uniform Load : D = 0.640 k /ft, Extent = 1.250 —» 3.750 ft, Tributary Width = 1.0 ft, (TE40;
DESIGN SUMMARY
Maximum Bending Stress Ratio =
Section used for this span
Mu : Applied
Mn " Phi : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward L +Lr +S Deflection
Max Upward L +Lr +S Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.433: 1
L4X4X1 /4
1.444 k -ft
3.337 k -ft
+1.40D
2.180ft
Span # 1
Maximum Shear Stress Ratio =
Section used for this span
Vu : Applied
Vn * Phi : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
0.000 in Ratio =
0.000 in Ratio =
0.033 in Ratio =
0.000 in Ratio =
0 <360
0 <360
1455
0 <180
Design OK
0.072 : 1
L4X4X1 /4
1.40 k
19.440 k
+1.40D
3.760 ft
Span # 1
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span # M V max Mu + max Mu -
Summary of Moment Values
Summary of Shear Values
Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi'Vnx
+1.40D
Dsgn. L = 4.00 ft 1 0.433 0.072 1.44
Overall Maximum Deflections - Unfactored Loads
Load Combination Span Max. " " Defl Location in Span
1.44 3.71 3.34 1.18 1.00 1.40 21.60 19.44
Load Combination
Max. " +" Defl Location in Span
1 0.0000 , 0.000
Maximum Deflections for Load Combinations - Unfactored Loads
Load Combination Span Max. Downward Defl Location in Span
0.0000
0.000
Max. Upward Defl Location in Span
D Only 1
Vertical Reactions - Unfactored
Load Combination Support 1
0.0330 2.080 0.0000 0.000
Support notation : Far left is #1 Values in KIPS
Support 2
Overall MAXimum
D Only
0.600
0.600
1.000
1.000
Steel Beam
Lic. # : KW- 06006053
Description : L4x4x1/4
Steel Section Properties : L4X4X114
Depth = 4.000 in 1 xx
Sxx
Leg Width = 4.000 in R xx
Thickness = 0.250 in Zx
Area = 1.940 1n82 1 yy
Weight = 6.600 pif S yy
Kdesign = 0.625 in R yy
Ycg
Yp
Eo
1.5
1.1
of
0.4
BEAM - -»
0.9
0.3
BEAN--»
a -03
1
-0.9
1.080 in
= 0.242 in
= 0.242 in
File: Z:\ Data\ StoragelCornerstonelEngineeringlAT &T1 _2012112 -13054 WA094 Tukwila BAT\Calcsltukwila bat.ec6
ENERCALC; INC. 1983-,2011, Builii:6.]1 12.7, Ver:6.11;12 :7
Licensee : CORNERTSTONE ENGINEERING INC.
Qs
lz
Sz
Rz
Tariff
3.00 in^4
1.03 103
1.250 in
1.820 in^3
3.000 in84
1.030 in83
1.250 in
0.910
1.180 in84
0.419 in83
0.783 in
1.00 deg
J = 0.044 in84
Cw = 0.05 106
Ro = 2.220 in
0.38
0.78
1.18
1.58
1.98
Distance (ft)
• !1.400
2.38
2J8
3.18
3.58
3.98
0.38
0.78
1.18
1.58
1.98
Distance (ft)
■ ♦1.4DD
238
2J8
3.18
3.58
3.98
BEAN - -»
-0.008
c6 -0.017
-0525
-0.034
0.38
0.78
1.18
158
1.98
Distance (ft)
• DO•y
238
2J8
3.18
358
3.98
EcoRNERs1roNE
• E N G I N E E R I N G , 1 N C.
project
by
location
date
sheet no.
!b
client
checked
date
CEI job no.
i120ftxgD crNt,T T,
(i
(TYP of i-k)
(E>
E� U1:‘,. M_N•t -v
SUPPock7 PrM . CoOM
E-T�Z�
EDPNERS1rDNE
E N G I N E E R I N G , I N C.
project
by
location
date
sheet no.
17
client
checked
date
CEI job no.
(OS EAM CAECA
d.
ox33 L.561.J
\
.
W ►o •,2d¢ LSgl Q.'1-
_
ji=
sz4
%‹
•
�s�
7.313
W\ iliqui
fu
i
LL1-1
TE Lj0
L� 13 .
(E)
U ate
(E)
NpKiA
la\
UMV
l7 Zl
(E)
Nokl>a
�53. .
6`>1 ,
Cep 44
vole
0.4.,;., I
Ft
= 4
HOF IiN
gox
R�
MOB
' drawer
P,\'i. f3■..
PI la-r P&P. 1M t is a n<,
DEA b 1.01S :
. (E' Moki 9S!13
(E) UMT S - 7`iU (b
(E) TE 3Za0 �e
. (E) TE?I. . Z( 1.b
(01-1OFFAhN. r1>\k.=
\-1\ .10 rc
(c),1 3
. (Q1 7_
S(zls�:_'S
is
EcoRNEFRs1raNE • E N G I N E E R I N G . I N C.
project
by
location
date
client
checked
date
sheet no.
Ig
CEI job no.
bEP U C_NELb. \-1x 13 U7-1
VJ7'-'T- WaokiA
t -1 i
Os�
j..512:4( Z,CF4 2 c4-
�F1
" L 1g- lbfr.t (L,--)
,(913 °V + 13 16Ic t aF B attw
BASED ON
LOCA TLot
(q5 Mai -
c 0. 21 < 1))
- . r 6 \i\v4, h D t Q U "V p s u P oki
eel =rBeam
Lic. # : KW- 06006053
Description : (E) W8x13 Beam (B2) (A)
Material Properties
File. Z: 01 211 2 -1 3 0 5 4 WA094.Tukwila BAT1Caliisltukwile bat:ec6
ENERCALC ,INC.:1983a2011'�Build.6:11 12 7;'Ver611 127:
Licensee : CORNERTSTONE ENGINEERING INC.
Calculations per AISC 360.05, IBC 2006, CBC 2007, ASCE 7.05
Analysis Method : Load Resistance Factor Design
Beam Bracing : Beam bracing is defined Beam -by -Beam
Bending Axis : Major Axis Bending
Load Combination 2006 IBC & ASCE 7 -05
Unbraced Lengths
Fy : Steel Yield :
E: Modulus :
36.0 ksi
29,000.0 ksi
Span # 1, Defined Brace Locations, First Brace at 3.0 ft, Second Brace at 5.50 ft, Third Brace at 8.0 ft
D(0.106)
D(0.4) + + + + +
+ + * * * + + D(0.06) L(0.1) + +
Span = 15.0 ft
W8x13
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.060, L = 0.10 k/ft, Tributary Width = 1.0 ft, (D + L
Uniform Load : D = 0.40 k /ft, Extent = 0.50 -» 3.0 ft, Tributary Width = 1.0 ft, (Te40
Uniform Load : D = 0.1060 k/ft, Extent = 3.0 - -» 8.0 ft, Tributary Width = 1.0 ft, (Nokia'
DESIGN SUMMARY
Design OK
Maximum Bending Stress Ratio = 0.321: 1 Maximum Shear Stress Ratio = 0.084: 1
Section used for this span W8x13 Section used for this span W8x13
Mu : Applied 9.877 k -ft Vu : Applied 3.320 k
Mn * Phi : Allowable 30.780 k -ft Vn * Phi : Allowable 39.694 k
Load Combination +1.20D+0.50Lr +1.60L +1.60H Load Combination +1.20D+0.50Lr +1.60L +1.60H
Location of maximum on span 6.675ft Location of maximum on span 0.000 ft
Span # where maximum occurs Span # 1 Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L +Lr +S Deflection 0.100 in Ratio = 1800
Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360
Max Downward Total Deflection 0.258 in Ratio = 696
Max Upward Total Deflection 0.000 in Ratio = 0 <180
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx
+1.40D
Dsgn. L = 3.00 ft 1 0.169 0.062 5.21 5.21 34.20 30.78 1.45 1.00 2.47 39.69 39.69
Dsgn. L = 2.48 ft 1 0.206 0.019 6.34 5.21 6.34 34.20 30.78 1.06 1.00 0.77 39.69 39.69
Dsgn. L = 2.48 ft 1 0.207 0.012 6.38 5.94 6.38 34.20 30.78 1.01 1.00 0.47 39.69 39.69
Dsgn. L = 7.05 ft 1 0.193 0.030 5.94 5.94 34.20 30.78 1.48 1.00 1.20 39.69 39.69
+1 .20 D+0.50 L r +1.60 L +1.60 H
Dsgn. L = 3.00 ft 1 0.239 0.084 7.35. 7.35 34.20 30.78 1.49 1.00 3.32 39.69 39.69
Dsgn. L = 2.48 ft 1 0.312 0.035 9.61 7.35 9.61 34.20 30.78 1.08 1.00 1.38 39.69 39.69
Dsgn. L = 2.48 ft 1 0.321 0.012 9.88 9.57 9.88 34.20 30.78 1.00 1.00 0.48 39.69 39.69
Dsgn. L = 7.05 ft 1 0.311 0.056 9.57 9.57 34.20 30.78 1.41 1.00 2.23 39.69 39.69
+1.20D +1.60L+0.50S +1.60H
Dsgn. L = 3.00 ft 1 0.239 0.084 7.35 7.35 34.20 30.78 1.49 1.00 3.32 39.69 39.69
Dsgn. L = 2.48 ft 1 0.312 0.035 9.61 7.35 9.61 34.20 30.78 1.08 1.00 1.38 39.69 39.69
Dsgn. L = 2.48 ft 1 0.321 0.012 9.88 9.57 9.88 34.20 30.78 1.00 1.00 0.48 39.69 39.69
Dsgn. L = 7.05 ft 1 0.311 0.056 9.57 9.57 34.20 30.78 1.41 1.00 2.23 39.69 39.69
+1.20D +1.60Lr+0.50L
Dsgn. L = 3.00 ft 1 0.174 0.063 5.37 5.37 34.20 30.78 1.46 1.00 2.50 39.69 39.69
Dsgn. L = 2.48 ft 1 0.219 0.022 6.74 5.37 6.74 34.20 30.78 1.07 1.00 0.88 39.69 39.69
Dsgn. L = 2.48 ft 1 0.222 0.011 6.84 6.49 6.84 34.20 30.78 1.01 1.00 0.43 39.69 39.69
Dsgn. L = 7.05 ft 1 0.211 0.035 6.49 6.49 34.20 30.78 1.45 1.00 1.41 39.69 39.69
+1.20D+0.50L +1.60S
Dsgn. L = 3.00 ft 1 0.174 0.063 5.37 5.37 34.20 30.78 1.46 1.00 2.50 39.69 39.69
Dsgn. L = 2.48 ft 1 0.219 0.022 6.74 5.37 6.74 34.20 30.78 1.07 1.00 0.88 39.69 39.69
Dsgn. L = 2.48 ft 1 0.222 0.011 6.84 6.49 6.84 34.20 30.78 1.01 1.00 0.43 39.69 39.69
cp)
Steel Beam
File: Z:1 Datal StoragelCornerstone \Engineering\AT &71_2012112 -13054 WA094 Tukwila BATICalcsltukwila bat,ec6
ENERCALC,.INC.. 1983- 2011,,Build :6:11 12.7, Vec6.11.12.7
Lic. # : KW- 06006053 Licensee : CORNERTSTONE ENGINEERING INC.
Description : (E) W8x13 Beam (B2) (A)
Load Combination Max Stress Ratios
Summary of Moment Values
Summary of Shear Values
Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi'Vnx
Dsgn. L = 7.05 ft 1 0.211 0.035 6.49 6.49 34.20 30.78 1.45 1.00 1.41 39.69 39.69
+1.20D+0.50Lr+0.50L +1.60W
Dsgn. L = 3.00 ft 1 0.174 0.063 5.37 5.37 34.20 30.78 1.46 1.00 2.50 39.69 39.69
Dsgn. L = 2.48 ft 1 0.219 0.022 6.74 5.37 6.74 34.20 30.78 1.07 1.00 0.88 39.69 39.69
Dsgn. L = 2.48 ft 1 0.222 0.011 6.84 6.49 6.84 34.20 30.78 1.01 1.00 0.43 39.69 39.69
Dsgn. L = 7.05 ft 1 0.211 0.035 6.49 6.49 34.20 30.78 1.45 1.00 1.41 39.69 39.69
+1.20D+0.50L+0.50S +1.60W
Dsgn. L = 3.00 ft 1 0.174 0.063 5.37 5.37 34.20 30.78 1.46 1.00 2.50 39.69 39.69
Dsgn. L = 2.48 ft 1 0.219 0.022 6.74 5.37 6.74 34.20 30.78 1.07 1.00 0.88 39.69 39.69
Dsgn. L = 2.48 ft 1 0.222 0.011 6.84 6.49 6.84 34.20 30.78 1.01 1.00 0.43 39.69 39.69
Dsgn. L = 7.05 ft 1 0.211 0.035 6.49 6.49 34.20 30.78 1.45 1.00 1.41 39.69 39.69
+1.20D+0.50L+0.20S+E
Dsgn. L = 3.00 ft 1 0.174 0.063 5.37 5.37 34.20 30.78 1.46 1.00 2.50 39.69 39.69
Dsgn. L = 2.48 ft 1 0.219 0.022 6.74 5.37 6.74 34.20 30.78 1.07 1.00 0.88 39.69 39.69
Dsgn. L = 2.48 ft 1 0.222 0.011 6.84 6.49 6.84 34.20 30.78 1.01 1.00 0.43 39.69 39.69
Dsgn. L = 7.05 ft 1 0.211 0.035 6.49 6.49 34.20 30.78 1.45 1.00 1.41 39.69 39.69
Overall Maximum Deflections • Unfactored Loads
Load Combination Span Max. " " Defl Location in Span Load Combination Max. " +" Defl Location in Span
1 0.0000 0.000 0.0000 0.000
Maximum Deflections for Load Combinations • Unfactored Loads
Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span
D Only 1 0.1587 7.200 0.0000 0.000
L Only 1 0.1000 7.575 0.0000 0.000
D+L 1 0.2585 7.275 0.0000 0.000
Vertical Reactions • Unfactored Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 2.517 1.609
D Only 1.767 0.859
L Only 0.750 0.750
D+L 2.517 1.609
Steel Section Properties : W8x13
Depth
Web Thick
Flange Width
Flange Thick
Area
Weight
Kdesign
K1
rts
Ycg
7.990 in I xx 39.60 in ^4 J = 0.087in^4
0.230 in S xx 9.91 in ^3 Cw = 40.80 in^6
4.000 in R xx = 3.210 in
0.255 in Zx = 11.400 in ^3
3.840 in ^2 I yy = 2.730 in"4
13.071 plf S yy = 1.370 in ^3
0.555 in R yy = 0.843 in
0.563 in Zy = 2.150 in ^3
1.030 in rT = 1.010 in
3.995 in
Wno
Sw
Of
Qw
7.740 in ^2
1.970 in^4
1.860 in ^3
5.550 in ^3
10
d. s
3
BEAM---rr
1.43
2.93
4.43
5.93
7.43
8.93
10,43
11.93
13.43
14.93
Distance (ft)
• +1.4DD • +1.2DD +0.5DL, +1.6DL +1.60M • +1.200 +1.601 +0.505 +1.60X • +1.2DD +1.601. +D.5OL • +1.ZDD +D.SOL +1.605 ■ +1.20D +D.S0L. +0.501 +1.6DW • .1.15D+0.501 ,11,505+1.61/W • +1.2DD +D.5D1 +0.205•
Steel': Beam.
Lic. # : KW- 06006053
Description : (E) W8x13 Beam (B2) (A)
File: Z:IDatalStorage\ Cornerstone \Engineering\AT &T1_2012112 -13054 WA094 Tukwila BATICalcsltukwila bat.ec6
ENERCALC, INC. 1983 -2011 Build 6..11.12.7, Ver.6.11:12:7`
Licensee : CORNERTSTONE ENGINEERING INC.
3.4
2.0
0.6
BEAM - -aa
-0.9
-2.3
1.43
2.93
4.43
5.93
7.43
Distance (ft)
• +1.40D • +1.1DD +D.SDL. +1.6DL+1.6DH • +1.2DD+L.6D L +D.SDS +1.6DH • +1.200 +1.6DL. +D.SDL • +1.2DD +D.5DL +1.665 • +1.211D+D.SDL.4D.SDL +1.66W • +1.2DD +D.SDL. I.SD5 +1.6DW • +1.2DD +D.SDL +5.251•
BEAM• -ss
8.93
10.43
11.93
13.43
14.93
-0.07
-0.13
-020
-0.26
1.43
2.93
4.43
5.93
7.43
Distance (ft)
• D O.1y • l O.1y • D +L
8.93
10.43
11.93
13.43
14.93
ECFRNERS1rDNE
E N G I N E E R I N G , I N C.
project
by
location
date
sheet no.
22 i
client
checked
date
CEI job no.
(E) 8 E \I\ Cpl- c ti %iss L
\IJURS7 LPI4 : \?a \'N\ --�_ (E) W t x \-
OtS Z� 2 s'
VDc: (leDk)r1") (&1S€1 a x-03 C.+
W, t -LS tr:.
.1)16g-p•pN 1-ac MC-OW
(17ra) (, T41,
\\ 3
33. \
'poKip; C
UMW - (jb(Z,s `(')
1s-c'bIPk--.
(2.covo.Iz,
c�. S3°■ \
(E >. �� xi3 Le∎I- )6•1 Qelk%. ARE. N'O patTe . 70 SuPi)dVN
PCZovc s E Qx-s.,Yo%N \
-Ste,eh Beam
Lic. # : KW- 06006053
Description : (E) W8x13 Beam (B3) (B)
Material. Properties
Analysis Method : Load Resistance Factor Design
Beam Bracing : Beam bracing is defined Beam -by -Beam
Bending Axis : Major Axis Bending
Load Combination 2006 IBC & ASCE 7 -05
Unbraced Lengths
. File: Z: IDatalSteragelComerstone1Engineenn61AT &T1_ 2012 \ 12 -1 3 0 5 4 WA094,TukWda'BAT1C6141tukwda •bet.ec6
:.'i; �. �. „ ;ENERCALC;;INC t9831200ciii l6%:)1�12;7'Ver611 12 ;7'!
Licensee : CORNERTSTONE ENGINEERING INC.
Calculations per AISC 360.05, IBC 2006, CBC 2007, ASCE 7 -05
Fy : Steel Yield : 36.0 ksi
E: Modulus : 29,000.0 ksi
Span # 1, Defined Brace Locations, First Brace at 3.0 ft, Second Brace at 5.50 ft, Third Brace at 8.0 ft
D(0.158)
+ I, * D(0.z33)
D(0.88) + * * * v
+ * * * + D(0.04875�L(0.08125)
+ ♦ * i
D(0.64)
+ i v
Span = 15.0 ft
W8x13
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.04875, L = 0.08125 k/ft, Tributary Width = 1.0 ft, (D + L
Uniform Load : D = 0.880 k/ft, Extent = 0.50 - -» 3.0 ft, Tributary Width = 1.0 ft, (TE40
Uniform Load : D = 0.2330 k /ft, Extent = 3.0 -» 8.0 ft, Tributary Width = 1.0 ft, (Nokia;
Uniform Load : D = 0.1580 k/ft, Extent = 3.0 -» 5.50 ft, Tributary Width = 1.0 ft, (UMTS'
Uniform Load : D = 0.640 k/ft, Extent = 10.0 - -» 12.50 ft, Tributary Width = 1.0 ft, (TE43;
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.539: 1
Section used for this span W8x13
Mu : Applied 16.586 k -ft
Mn * Phi : Allowable 30.780 k -ft
Load Combination +1.20D+0.50Lr +1.60L +1.60H
Location of maximum on span 6.825ft
Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L +Lr +S Deflection
Max Upward L +Lr +S Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Maximum Shear Stress Ratio =
Section used for this span
Vu : Applied
Vn * Phi : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
0.081 in Ratio = 2215
0.000 in Ratio = 0 <360
0.478 in Ratio = 376
0.000 in Ratio = 0 <180
Design OK
0.140 : 1
W8x13
5.568 k
39.694 k
+1 .2 0 D+0.50 L r +1.60 L +1.6 0 H
0.000 ft
Span # 1
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span # M V
Summary of Moment Values Summary of Shear Values
max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi'Vnx
+1.40D
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D+0.50Lr +1.60L +1.60H
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D +1.60L+0.50S +1.60H
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D +1.60Lr+0.50L
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D+0.50L +1.60S
Dsgn. L = 3.00 ft
0.385 0.135 11.84 11.84 34.20 30.78 1.47 1.00 5.36 39.69 39.69
0.484 0.051 14.89 11.84 14.89 34.20 30.78 1.07 1.00 2.02 39.69 39.69
0.492 0.015 15.13 14.73 15.13 34.20 30.78 1.00 1.00 0.58 39.69 39.69
0.479 0.087 14.73 14.73 34.20 30.78 1.31 1.00 3.44 39.69 39.69
0.406 0.140 12.49 12.49 34.20 30.78 1.49 1.00 5.57 39.69 39.69
0.525 0.058 16.16 12.49 16.16 34.20 30.78 1.08 1.00 2.32 39.69 39.69
0.539 0.016 16.59 16.16 16.59 34.20 30.78 1.00 1.00 0.65 39.69 39.69
0.529 0.099 16.27 16.27 34.20 30.78 1.32 1.00 3.93 39.69 39.69
0.406 0.140 12.49 12.49 34.20 30.78 1.49 1.00 5.57 39.69 39.69
0.525 0.058 16.16 12.49 16.16 34.20 30.78 1.08 1.00 2.32 39.69 39.69
0.539 0.016 16.59 16.16 16.59 34.20 30.78 1.00 1.00 0.65 39.69 39.69
0.529 0.099 16.27 16.27 34.20 30.78 1.32 1.00 3.93 39.69 39.69
0.353 0.123 10.88 10.88 34.20 30.78 1.48 1.00 4.90 39.69 39.69
0.449 0.048 13.83 10.88 13.83 34.20 30.78 1.07 1.00 1.91 39.69 39.69
0.458 0.013 14.10 13.77 14.10 34.20 30.78 1.00 1.00 0.51 39.69 39.69
0.447 0.082 13.77 13.77 34.20 30.78 1.31 1.00 3.26 39.69 39.69
1 0.353 0.123 10.88 10.88 34.20 30.78 1.48 1.00 4.90 39.69 39.69
Steel Beam
Lic. # : KW- 06006053
Description : (E) W8x13 Beam (B3) (B)
Load Combination
Segment Length
Max Stress Ratios
File: Z:1 DatatStoragelComerstone \EngineeringlAT &Tl_2 01 211 2 -1 3 0 5 4 WA094 Tukwila BAT1Calcsltukwila batec6
ENERCALC, INC. 1983 -2011, Build:6.11.12.7, Ver..6.11.12.7
Licensee : CORNERTSTONE ENGINEERING-INC.
Summary of Moment Values
Span # M V max Mu + max Mu - Mu Max
Mnx Phi*Mnx Cb Rm
Summary of Shear Values
VuMax Vnx Phi'Vnx
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D+0.50Lr+0.50L +1.60W
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D+0.50L+0.50S +1.60W
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
+1.20D+0.50L+0.20S+E
Dsgn. L = 3.00 ft
Dsgn. L = 2.48 ft
Dsgn. L = 2.48 ft
Dsgn. L = 7.05 ft
0.449
0.458
0.447
0.048
0.013
0.082
13.83
14.10
13.77
10.88
13.77
13.83
14.10
13.77
34.20 30.78 1.07 1.00 1.91 39.69 39.69
34.20 30.78 1.00 1.00 0.51 39.69 39.69
34.20 30.78 1.31 1.00 3.26 39.69 39.69
0.353 0.123 10.88 10.88 34.20 30.78 1.48 1.00 4.90 39.69 39.69
0.449 0.048 13.83 10.88 13.83 34.20 30.78 1.07 1.00 1.91 39.69 39.69
0.458 .0.013 14.10 13.77 14.10 34.20 30.78 1.00 1.00 0.51 39.69 39.69
0.447 0.082 13.77 13.77 34.20 30.78 1.31 1.00 3.26 39.69 39.69
0.353 0.123 10.88 10.88 34.20 30.78 1.48 1.00 4.90 39.69 39.69
0.449 0.048 13.83 10.88 13.83 34.20 30.78 1.07 1.00 1.91 39.69 39.69
0.458 0.013 14.10 13.77 14.10 34.20 30.78 1.00 1.00 0.51 39.69 39.69
0.447 0.082 13.77 13.77 34.20 30.78 1.31 1.00 3.26 39.69 39.69
0.353 0.123
0.449 0.048
0.458 0.013
0.447 0.082
Overall Maximum Deflections - Unfactored Loads
10.88 10.88 34.20 30.78 1.48 1.00 4.90 39.69 39.69
13.83 10.88 13.83 34.20 30.78 1.07 1.00 1.91 39.69 39.69
14.10 13.77 14.10 34.20 30.78 1.00 1.00 0.51 39.69 39.69
13.77 13.77 34.20 30.78 1.31 1.00 3.26 39.69 39.69
Load Combination Span Max. " " Defl Location in Span
Load Combination
Max. " +" Defl Location in Span
1 0.0000 0.000
Maximum Deflections for Load Combinations • Unfactored Loads
Load Combination Span Max. Downward Defl Location in Span
0.0000 0.000
Max. Upward Defl
Location in Span
D Only
L Only
D+L
0.3969
0.0812
0.4781
Vertical Reactions - Unfactored
Load Combination Support 1 Support 2
7.425
7.575
7.425
Support notation : Far left is #1
0.0000
0.0000
0.0000
0.000
0.000
0.000
Values in KIPS
Overall MAXimum 4.437 3.069
D Only 3.828 2.459
L Only 0.609 0.609
D+L 4.437 3.069
Steel Section Properties W8x13
Depth = 7.990 in I xx
Web Thick = 0.230 in
Flange Width = 4.000 in
Flange Thick = 0.255 in
Area = 3.840 inA2
Weight = 13.071 plf
Kdesign = 0.555 in
K1 = 0.563 in
rts = 1.030 in
Ycg = 3.995 in
Sxx
R xx
Zx
Iyy
Syy
R yy
Zy
rT
39.60 in"4
9.91 inA3
= 3.210 in
11.400 in93
2.730 in"4
= 1.370 in "3
= 0.843 in
= 2.150 in "3
1.010 in
J
Cw
Wno
Sw
Of
Qw
0.087 in "4
40.80in"6
7.740 inA2
1.970 in "4
1.860 in "3
5.550 in "3
1
17
13
4
BEAK-»
1.43
2.93
4.43
5.93
7.43
0.93
10.43
11.93
13.43
14.93
Distance (Ft)
■ +1.40D • +1.2DD +0.S0L. +I.6DL+1.60M • +1.200 +I.6DL+D.SDS +1.609 • +1.20D +1.600+1).SDL • +1.200 +D.SDL +1.605 • a1- 200 +D.SDL. +D.SDl +1.60W • +1.20D +D.SDL +0.505 +1.60W • . 1.20D+D.SDl +D.2D5•
Steel Beam
Lic. # : KW- 06006053
Description : (E) W8x13 Beam (B3) (B)
File: Z:IData\ Storage \CornerstonelEngineeringlAT &T1 _2012112 -13054 WA094 Tukwila BAT1Calcsltukwila bal.ec6
ENERCALC, INC. 1983 2011, Build:6.11.12.7, Ver.6.11.12.7
Licensee : CORNERTSTONE ENGINEERING INC.
5J
3.3
BEAM - -aa
•1b
4.0
1.43
2.93
4.43
5.93
7.43
8.93
10.43
11.93
13.43
14.93
Distance (ft)
• +1.40D • +1.2DD +O.SDL. +1.6DL+1.60M • +1.20D +L.6DL+0.S05+1.60M • +1.20D +1 -601 +D.SDL • •1 205+0 501.+1 605 • +1 255+0 SDL. +0.SSL +1.60W • +1.205 +0.50L +5.505 +1.60W • +1.205 +0.S0L +5.201•
BEAK -aa
-0.12
t6 -024
-037
-0A9
1.43
2.93
4.43
5.93
7.43
Distance (ft)
• DO•ly • LO•ly • D +L
833
10.43
11.93
13.43
14.93
ECORNEFS1rONE
— ENGINEERING, INC.
project
by
location
date
sheet no.
client
checked
date
CEljob no.
E I E (e).5EPA 0.. W10.
DE1 E FRou� 1 La. 13-
(mT.c E .(b zI 4 Cg�1 14acr 1. P\O- a E E N. r,E R AT'0 40
R
Ac.-.oNS
.4" ,>,�L= ,s lbl�� c t 1IFr
3 a tb I -r 1 ' b ` tr*. ttf-',M°
Ww ✓ 'b!F¢'-
(o\%
R,�. 3z3110
R1C4- 1-1
Cu.:1 (umoN,C))
R3 ZSI"Jlb
�S =
. '7511
RZ, D511%
1 '7(; 1Ib
lb
_Acs 1_61')5 (_Z) R,1\ O )
41-111
It
,-;fit'' 300
RsDL = 3z1 %l l;
lb
3i.` OSOte
krL-t_ a
_ 6C)°\ 43
kSLS 36
RsAL (I)"
Lcc
1/4J3‘ ZSPC.
EOFRNER.IrONE
E N G I N E E R I N G,
I N C.
project
by
location
date
sheet no.
2.7/
client
checked
date
CEI job no.
ENC.1- 1.00S C6H]
WNW fix:
OleN
Z,S `i■5‘ 2.s' ' 2.s' RQ
)K
11r Ft (Y1 )
/ 21 s 91')-
x'6116 R,,.DL I lye'`' k) u. - (oo` b . : .
'Rs ; Z3°�0e R, 0, ' I NI 15 4� (ao� . . •
to l& (55]
41 41
QT) ``�.��bl ct- i 13'bIFE
wib , ; (I_Mtb 1114> �ZJ
12,s'bICI
Rq -.1074'6. 12‘ .�t(�$�b ; :(00°0'
R ��
10 7S je. R,v DL 96`\16 tot.1.. ‘6Y6
-C O R N E R S I ONE
E N G I N E E R I N G,
I N C.
project
by
location
date
sheet no.
client
checked
date
CEljob no.
PuTIos
46.4.
1R„ TRiz-
EcoRNEiRs1rcNE
E N G I N E E R I N G,
I N C.
project
by
location
date
sheet no.
24/
client
checked
date
CEIjob no.
.B.AM OC.NEC..k W I0KsC673
L
4,61
pkw RRU LOUS
R : /silt b
Rs-: N43�1
R,‘ = 10'11-0
R1= T %Lt1'
MtA = o,$zS < OK.
32316
Ram t 17(07'5
R414- 3$Zet'b
7� = 119B1b
1Z DL t 33 3Z3
Loi3s.
.1113 S•7 N1t�.
w 10 x 33 Cx-71 'V■ t PD Ea u IN-CE • O s u t'POK1 : PRO POS E .
NT (- MIT 1--)EZ
Steel Beam
Lic. # : KW- 06006053
Description : (E) W10x33 Beam (C) [B7]
Material Properties
File: Z:1 DatalStorage \CornerstonelEngineeringlAT &71_2012112 -13054 WA094 Tukwila BATICalcsltukwila bat.ec6
ENERCALC, INC. 1983-2011, Build:6.11.12.7, Ver..6.11.12.7
Licensee : CORNERTSTONE ENGINEERING INC.
Calculations per AISC 360-05, IBC 2006, CBC 2007, ASCE 7-05
Analysis Method : Load Resistance Factor Design
Beam Bracing : Beam bracing is defined Beam -by -Beam
Bending Axis : Major Axis Bending
Load Combination 2006 IBC & ASCE 7 -05
Unbraced Lengths
Span # 1, Braced @ 1/3 Points
Fy : Steel Yield :
E: Modulus :
36.0 ksi
29,000.0 ksi
D(0.323) L(0.375) D(1.767
L(0.75) D(3.828) L(0.8D*1).148) L(0.609) D(0.465) L(0.6114332) L(0.516)
Span = 27.750 ft
W10X33
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load(s) for Span Number 1 •
Point Load : D = 0.3230, L = 0.3750 k (a) 8.0 ft
Point Load : D = 1.767, L = 0.750 k (x)12.0 ft
Point Load : D = 3.828, L = 0.6090 k aA,16.0 ft
Point Load : D = 1.148, L = 0.6090 k (x)18.50 ft, (R7)
Point Load : D = 0.4650, L = 0.6090 k (a, 22.50 ft, (R9)
Point Load : D = 3.332, L = 0.5160 k [?o, 25.0 ft, (R11)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.825: 1
Section used for this span W10X33
Mu : Applied 86.406 k -ft
Mn * Phi : Allowable 104.760 k -ft
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward L +Lr +S Deflection
Max Upward L +Lr +S Deflection
Max Downward Total Deflection
Max Upward Total Deflection
+1.20D+0.50Lr +1.60L +1.60H
15.956ft
Span # 1
Maximum Shear Stress Ratio =
Section used for this span
Vu : Applied
Vn * Phi : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
0.408 in Ratio =
0.000 in Ratio =
1.731 in Ratio =
0.000 in Ratio =
816
0 <360
192
0 <180
Design OK
0.207 : 1
W10X33
12.638 k
60.949 k
+1.20D+0.50 Lr +1.60L +1.60H
27.750 ft
Span # 1
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span # M V
Summary of Moment Values
Summary of Shear Values
max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx
+1.40D
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1.20D+0.50Lr +1.60L +1.60H
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1 .20 D +1.60 L+0.50S +1.60 H
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1.20D +1.60Lr+0.50L
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1.20D+0.50L +1.60S
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
1 0.480 0.094 50.27
1 0.693 0.080 72.61
1 0.616 0.176 64.54
1 0.589 0.116 61.73
1 0.825 0.093 86.41
1 0.743 0.207 77.88
1 0.589 0.116 61.73
1 0.825 0.093 86.41
1 0.743 0.207 77.88
1 0.467 0.092 48.91
1 0.666 0.076 69.79
1 0.595 0.169 62.37
1 0.467 0.092 48.91
1 0.666 0.076 69.79
1 0.595 0.169 62.37
50.27 116.40
50.27 72.61 116.40
64.54 116.40
61.73 116.40
61.73 86.41 116.40
77.88 116.40
61.73 116.40
61.73 86.41 116.40
77.88 116.40
48.91 116.40
48.91 69.79 116.40
62.37 116.40
48.91 116.40
48.91 69.79 116.40
62.37 116.40
104.76 1.65 1.00 5.76 60.95 60.95
104.76 1.06 1.00 4.88 60.95 60.95
104.76 1.44 1.00 10.73 60.95 60.95
104.76 1.64 1.00 7.05 60.95 60.95
104.76 1.06 1.00 5.70 60.95 60.95
104.76 1.44 1.00 12.64 60.95 60.95
104.76 1.64 1.00 7.05 60.95 60.95
104.76 1.06 1.00 5.70 60.95 60.95
104.76 1.44 1.00 12.64 60.95 60.95
104.76 1.65 1.00 5.60 60.95 60.95
104.76 1.06 1.00 4.66 60.95 60.95
104.76 1.44 1.00 10.27 60.95 60.95
104.76 1.65 1.00 5.60 60.95 60.95
104.76 1.06 1.00 4.66 60.95 60.95
104.76 1.44 1.00 10.27 60.95 60.95
Steel Beam
Lic. # : KW- 06006053
Description : (E) W10x33 Beam (C) [B71
Load Combination Max Stress Ratios
Segment Length Span # M V
File: Z:1DatalStoragelCornerstone \Engineering AT &Tt_2012112 -13054 WA094 Tukwila BATICalcsltukwila bat.ec6
ENERCALC, INC. 1983 -2011, Build:6.11.12.7, Ver.6.11.12.7
Licensee : CORNERTSTONE ENGINEERING INC.
Summary of Moment Values
max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm
Summary of Shear Values
VuMax Vnx Phi *Vnx
+1.20D+0.50Lr+0.50L +1.60W
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1.20D+0.50L+0.50S +1.60W
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
+1 .20 D+0.50 L+0.20 S 4E
Dsgn. L = 9.16 ft
Dsgn. L = 9.30 ft
Dsgn. L = 9.30 ft
0.467 0.092 48.91 48.91 116.40 104.76 1.65 1.00 5.60 60.95 60.95
0.666 0.076 69.79 48.91 69.79 116.40 104.76 1.06 1.00 4.66 60.95 60.95
0.595 0.169 62.37 62.37 116.40 104.76 1.44 1.00 10.27 60.95 60.95
0.467 0.092 48.91 48.91 116.40 104.76 1.65 1.00 5.60 60.95 60.95
0.666 0.076 69.79 48.91 69.79 116.40 104.76 1.06 1.00 4.66 60.95 60.95
0.595 0.169 62.37 62.37 116.40 104.76 1.44 1.00 10.27 60.95 60.95
0.467
0.666
0.595
0.092
0.076
0.169
48.91
69.79 48.91
62.37
48.91 116.40 104.76 1.65 1.00 5.60 60.95 60.95
69.79 116.40 104.76 1.06 1.00 4.66 60.95 60.95
62.37 116.40 104.76 1.44 1.00 10.27 60.95 60.95
Overall Maximum Deflections - Unfactored Loads
Load Combination Span Max. " " Defl Location in Span Load Combination
Max. " +" Defl Location in Span
1 0.0000 0.000
Maximum Deflections for Load Combinations - Unfactored Loads
Load Combination Span Max. Downward Dell Location in Span
0.0000
0.000
Max. Upward Defl
Location in Span
D Only
L Only
D+L
1.3228
0.4078
1.7306
14.430
14.291
14.430
Vertical Reactions - Unfactored Support notation : Far left is #1
0.0000
0.0000
0.0000
0.000
0.000
0.000
Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum
D Only
L Only
D4
Steel Section Properties :
Depth =
Web Thick
Flange Width
Flange Thick
Area
Weight
Kdesign
K1
rts
Ycg
5.433
4.113
1.320
5.433
W10X33
9.730 in
0.290 in
7.960 in
0.435 in
9.710 in62
33.053 plf
0.935 in
0.750 in
2.200 in
4.865 in
9.815
7.667
2.148
9.815
Ixx
Sxx
Rxx
Zx
Iyy
Syy
Ryy
Zy
rT
171.00 in64
35.00 in "3
4.190 in
38.800 4n63
36.600 in64
9.200 in63
1.940 in
14.000 in83
2.140 in
Cw
Wno
Sw
Qf
Qw
0.583 inA4
= 791.00 in66
18.500 in62
16.000 in44
7.750 in63
18.900 in "3
6
se
66
44
22
BEAM- -s»
2.64 5.41
8,19
10.96
13.74
16.51
1929
22 0S
24.84
27.61
Distance (k)
• +1.41)8 • •1.20D +D.50L. +1.6DL +1.60N • +1.2DD +1.6Dl +D.SD5+1.60M • +1.2DD.1.6D1. +0 SDL • +1.180 +5 55L+1 650 • .1.200 +15.5DL..D.SDL +1.60W • +1.108 +D.SDL +0.505 +1.6DW • +1.200+D.SDL +8.2115•
Steel Beam
Lic. # : KW- 06006053
Description :
(E) W10x33 Beam (C) [B7]
File: Z:1 DatalStoragelComerstonelEngineeringlAT8T1 _2012112 -13054 WA094 Tukwila BAT\Calcsttukwila bat.ec6
,,.ENERGALC, INC. 1983 -2011, Bui0;6;11:12.7, Vec6.11.12.7
Licensee : CORNERTSTONE ENGINEERING INC.
7
2
BEAM - ->a
-3
•8
-13
1
L
t__
1
2 .64
5.41
8.19
10.96
13.74
16.51
19.29
22.06
24.84
27.61
Distance (ft)
• +1.400 • •1.200 +D.SDL. +1.6D1+1.6DH • +1.2DD•1.6DL +15.5D5 +1.609 • +1.210 +1.601.+D.5DL • ♦1.200 +D.SSL +1.6DS • +1.20D +O.5D1..+D.5DL +1.6DW • +1.2DD•D.SDL +D.SD5+1.6OW • ♦1.2DD+11.50L+D.2DS•
BEAM--»
-0.4
:::s" -0.9
2
-1.3
•1.8
2.64
5.41
8.19
10.96
13.74
Distance (ft)
■DO.y•LO.y•D +l
16.51
19.29
22.06
24.84
27.61
EICQFNEFIS1rc3NE N G I N E E R I N G. I N C.
project
by
location
date
sheet no.
33i
client
checked
date
CEI job no.
3 E ( D ) . C,N ECk \,J 10 , [6q
WZf tI WTe 2 uTr .to
re Ire 2•Ss
1°- tOifttitia DV.
VACC
k 5 ! ( KIN 1 •
R \3
r(901°
•
Rte LL 2\
P\N LY . %ER \3 \, x GVCI :
O.y
' 6 5 •
e) .(t,E(101131.01 AN1051.$)
•
0`
I '
Lo�S
WamINM' ruaty�k\.
c.?ow\ VRv.Uzokx r :
QZ_ (oq`e ll' = s Z3t6
zn L
(601 ,
Pw . �,,
�b
IL Ot_ "' \10
'1 ; _23 `k0'b �eot ' I �glty
gib-- 10'70' P+o1ak_ V\ I b
R11- 1-LiA(01' R,D� 1V442'6
,
Rz«= 3'7S'b
°L-∎- ut ,ID,t'Z
•
ECOFINERSYONE
E N G I N E E R I N G . I N C.
project
by
location
date
sheet no.
3H i
client
checked
date
CEI job no.
M : 0, •114 < 1.0 O k
0
60
(E" \3'bx2L, L1%1 BEPtil\ Ts: ADS- QuPSTE,. 7.0 s& Wt PoPSED.
UItiM .`n1T
NE F.10 LaY Nve N 1) ?l- 1 Fa S
i-ve L,O6D cow tvo., OF
S U S \zyr.t►J (, . iss LL LO p,DS \-\.\\) � TZ, Q�S FAR ILO i cy.
•Votlt\)
StteelriBe 111
Lic. # : KW- 06006053
Description : (E) W10x26 Beam [B8]
Material Properties
Analysis Method : Load Resistance Factor Design
Beam Bracing : Beam bracing is defined Beam -by -Beam
Bending Axis : Major Axis Bending
Load Combination 2006 IBC & ASCE 7 -05
Unbraced Lengths
Span # 1, Defined Brace Locations, First Brace at 1.50 ft, Second Brace at 16.50 ft, Third Brace at ft
File: Z 1DatalSterage1ComerstonelEngirieenngWT &t2012112- 13054 :WA094„Tukwda'BA1wCalcsltukwila bat e0
,;: ^r • ' • :ENERCAL'C.INC.z 1983. 201 'PBiId; 6`_1112.7,�U,er611127:,
Licensee : CORNERTSTONE ENGINEERING INC.
Calculations per AISC 360-05, IBC 2006, CBC 2007, ASCE 7 -05
Fy : Steel Yield : 36.0 ksi
E: Modulus : 29,000.0 ksi
D(0.64)
D(0.52) + V V + +
D(7.667) L(2.148)
D(0.64)
+ * v v
D(5.694) L(2.148)
Span = 18.0 ft
W10X26
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load(s) for Span Number 1
Point Load: D= 7.667, L = 2.148 k a 1.50 ft
Uniform Load : D = 0.640 k/ft, Extent = 3.0 -» 5.50 ft, Tributary Width = 1.0 fl
Uniform Load : D = 0.520 k/ft, Extent = 5.50 -» 8.0 ft, Tributary Width = 1.0 fi
Uniform Load : D = 0.640 k/ft, Extent = 8.0 -» 10.50 ft, Tributary Width = 1.0 ft, (R7'
Point Load : D = 5.694, L = 2.148 k 16.50 ft, (R9)
DESIGN SUMMARY
Design OK
Maximum Bending Stress Ratio = 0.544: 1 Maximum Shear Stress Ratio = 0.278 : 1
Section used for this span W10X26 Section used for this span W10X26
Mu : Applied 36.527 k -ft Vu : Applied 16.095 k
Mn * Phi : Allowable 67.200 k -ft Vn ' Phi : Allowable 57.845 k
Load Combination +1.20D+0.50Lr +1.60L +1.60H Load Combination +1.20D+0.50Lr +1.60L +1.60H
Location of maximum on span 7.560ft Location of maximum on span 0.000 ft
Span # where maximum 'occurs Span # 1 Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L +Lr +S Deflection 0.054 in Ratio = 4000
Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360
Max Downward Total Deflection 0.430 in Ratio = 502
Max Upward Total Deflection 0.000 in Ratio = 0 <180
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi *Vnx
+1.40D
Dsgn. L = 1.44 ft 1 0.251 0.255 21.23 21.23 93.90 84.51 1.67 1.00 14.77 57.84 57.84
Dsgn. L = 15.03 ft 1 0.538 0.254 36.60 16.38 36.60 75.63 68.07 1.09 1.00 14.72 57.84 57.84
Dsgn. L = 1.53 ft 1 0.194 0.188 16.38 16.38 93.90 84.51 1.59 1.00 10.89 57.84 57.84
+1.20D+0.50Lr +1.60L +1.60H
Dsgn. L = 1.44 ft 1 0.274 0.278 23.14 23.14 93.90 84.51 1.67 1.00 16.09 57.84 57.84
Dsgn. L = 15.03 ft 1 0.544 0.277 36.53 19.20 36.53 74.67 67.20 1.08 1.00 16.05 57.84 57.84
Dsgn. L = 1.53 ft 1 0.227 0.221 19.20 19.20 93.90 84.51 1.59 1.00 12.77 57.84 57.84
+1.20D +1.60L+0.505 +1.60H
Dsgn. L = 1.44 ft 1 0.274 0.278 23.14 23.14 93.90 84.51 1.67 1.00 16.09 57.84 57.84
Dsgn. L = 15.03 ft 1 0.544 0.277 36.53 19.20 36.53 74.67 67.20 1.08 1.00 16.05 57.84 57.84
Dsgn. L = 1.53 ft 1 0.227 0.221 19.20 19.20 93.90 84.51 1.59 1.00 12.77 57.84 57.84
+1.20D +1.60Lr+0.50L
Dsgn. L = 1.44 ft 1 0.234 0.237 19.74 19.74 93.90 84.51 1.67 1.00 13.73 57.84 57.84
Dsgn. L = 15.03 ft 1 0.487 0.237 32.98 15.65 32.98 75.29 67.76 1.09 1.00 13.69 57.84 57.84
Dsgn. L = 1.53 ft 1 0.185 0.180 15.65 15.65 93.90 84.51 1.59 1.00 10.41 57.84 57.84
+1.20D+0.50L +1.60S
Dsgn. L = 1.44 ft 1 0.234 0.237 19.74 19.74 93.90 84.51 1.67 1.00 13.73 57.84 57.84
Dsgn. L = 15.03 ft 1 0.487 0.237 32.98 15.65 32.98 75.29 67.76 1.09 1.00 13.69 57.84 57.84
Dsgn. L = 1.53 ft 1 0.185 0.180 15.65 15.65 93.90 84.51 1.59 1.00 10.41 57.84 57.84
+1.20D+0.50Lr+0.50L +1.60W
tee I` Bead»
Lic. # : KW- 06006053
Description : (E) W10x26 Beam [B8]
Load Combination Max Stress Ratios
ViT &
File -Z IDattalStoragelCom- ersttielEngmeenng,\2012112 -13054 WfA094 Tukwda1BATlalcsltuk fla 6atec6
.,, "1.,�„; NERCALC: INC 1983 201W ,Budd 6111. 27, Ver611412j,7
Licensee : CORNERTSTONE ENGINEERING INC.
Summary of Moment Values
Summary of Shear Values
Segment Length Span # M V max Mu + max Mu - Mu Max Mnx Phi *Mnx Cb Rm VuMax Vnx Phi *Vnx
Dsgn. L = 1.44 ft 1 0.234 0.237 19.74 19.74 93.90 84.51 1.67 1.00 13.73 57.84 57.84
Dsgn. L = 15.03 ft 1 0.487 0.237 32.98 15.65 32.98 75.29 67.76 1.09 1.00 13.69 57.84 57.84
Dsgn. L = 1.53 ft 1 0.185 0.180 15.65 15.65 93.90 84.51 1.59 1.00 10.41 57.84 57.84
+1.20D+0.50L+0.50S +1.60W
Dsgn. L = 1.44 ft 1 0.234 0.237 19.74 19.74 93.90 84.51 1.67 1.00 13.73 57.84 57.84
Dsgn. L = 15.03 ft 1 0.487 0.237 32.98 15.65 32.98 75.29 67.76 1.09 1.00 13.69 57.84 57.84
Dsgn. L = 1.53 ft 1 0.185 0.180 15.65 15.65 93.90 84.51 1.59 1.00 10.41 57.84 57.84
+1.20D+0.50L+0.20S+E
Dsgn. L = 1.44 ft 1 0.234 0.237 19.74 19.74 93.90 84.51 1.67 1.00 13.73 57.84 57.84
Dsgn. L = 15.03 ft 1 0.487 0.237 32.98 15.65 32.98 75.29 67.76 1.09 1.00 13.69 57.84 57.84
Dsgn. L = 1.53 ft 1 0.185 0.180 15.65 15.65 93.90 84.51 1.59 1.00 10.41 57.84 57.84
Overall Maximum Deflections - Unfactored Loads
Load Combination Span Max. " " Defl Location in Span Load Combination Max. " +" Defl Location in Span
1 0.0000 0.000 0.0000 0.000
Maximum Deflections for Load Combinations - Unfactored Loads
Load Combination Span Max. Downward Defl Location in Span Max. Upward Defl Location in Span
D Only 1 0.3762 8.730 0.0000 0.000
L Only 1 0.0540 9.090 0.0000 0.000
D+L 1 0.4301 8.730 0.0000 0.000
Vertical Reactions - Unfactored Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 12.696 9.927
D Only 10.548 7.779
L Only 2.148 2.148
D+L 12.696 9.927
Steel Section Properties : W10X26
Depth = 10.300 in
Web Thick
Flange Width
Flange Thick
Area
Weight
Kdesign
K1
rts
Ycg
▪ 0.260 in
• 5.770 in
• 0.440 in
• 7.610 in82
= 25.904 plf
• 0.740 in
= 0.688 in
• 1.580 in
▪ 5.150 in
Ixx
Sxx
R xx
Zx
Iyy
Syy
Ryy
Zy
rT
144.00 104 J = 0.402 in84
27.90 in83 Cw = 345.00 inA6
4.350 in
31.300 in83
14.100 inA4
4.890 inA3
1.360 in
7.500 in83
1.540 in
Wno
Sw
Qf
Qw
14.200 inA2
9.030 in84
5.980 inA3
15.400 inA3
37
29
. 19
9
BEAM - -ss
1 .71 3S1 531 7.11
8.91
10.71
12.51
14.31
16.11
17.91
Distance (ft)
• +1.41)D • +1.20D +D.501. +1.60L +1.6DM • +1.2DD +1.60\ +0.501 +1.609 • +1.2DD +1.6D1,•D.SDL • +1.2DD +D.S15L +1.6DS • +1.2DD +D.SDL.+D.SDL+1.6DW • +1.2DD +D.SDL +D.SD5 +1.60W • +1.21)D+0.SOL +9.205.
r
Steel °Beam
Lic. # : KW- 06006053
Description :
(E) W10x26 Beam [B8]
File: Z:\ Data\ StoragelCornerstonelEngineeringlAT &T1 _2012112 -13054 WA094 Tukwila BAT1Calcsltukwila batec6
ENERCALC, INC 1983-2011, Build :6.11.12.7;.Ver :6.11.12.7
Licensee : CORNERTSTONE ENGINEERING INC.
16
L 2
BEAM---3.»
-0
-13
i
1 .71
3.51
531
7.11
8.91
10.71
12.51 •
14.31
16.11
17.91
Distance (ft)
' • •I.4DD • +1.2DD +D.SOL. +I.6DL+1.6DN • +1.100+1.60L+D.SD5 +1.6DN • +1.100+1.601. +0.61L • +1.20D+0.SOL +1.605 • +1.2DD+0.5DL. +1).5DL +1.60W ■ +1.20D+D.S01.+0.505 +1.60W • +1.200 +0.SOL•D.2DS•
BEAM - - -»
-0.11
g -0.22
-033
-0.44
1.71
3.51
5.31
7.11
8.91
Distance (Ft)
• DO•ly • LO•ly • D +l
10.71
12.51
14,31
16.11
17.91
a
Project: WA094 Tukwila Date: May 7, 2012
Client: AT &T Prepared By: J. Ricardi
CEI No.: 12 -13054 Page 3'%
References
1) Minimum Design Loads for Buildings and Other Structures, American Society of Civil
Engineering (ASCE 7 -05), 2006.
2) International Building Code (IBC 2009), International Code Council, 2009.
3) Manual of Steel Construction, American Institute of Steel Construction, Inc., 13th Ed., 2005.
4) National Design Specification for Wood Construction (NDS 2005), American Wood Council,
2005.
5) Structural Engineering Library Version 6.12.03.12, EnerCalc Engineering Software, 2011.
16928 Woodinville - Redmond Rd NE, Suite 21'0
Woodinville, WA 98072
Email: cei @cornerstone - engr.com
Web: www.cornerstone- engr.com
CORNERS-TONE
E N G I N E E R I N G , I N C.
Phone: (425) 487 -1732
(206) 250 -7306
Fax: (425) 487 -1734
12 -03 -2012
City of Tukwila
hrti: Haggerton, Mayor
Departrent of Community Development Jack Pace, Director
SUNNY AUSINK
111 S JACKSON ST, SUITE 200
SEATTLE WA 98104
RE: Permit No. D12 -174
AT &T
16500 SOUTHCENTER PY TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 01/21/2013.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 01/21/2013, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
04-41)(
fer Marshall
it Technician
File: Permit File No. DI2 -174
6300 Southceriter Boulevard Suite- #100'• 'Ta kwila, Washington 98188• Phone 206-431 -3670 • Fcxx 206431 -3665
PENT GULM1G�PY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -174 DATE: 05 -23 -12
PROJECT NAME: AT &T MOBILITY
SITE ADDRESS: 16500 SOUTHCENTER PY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEEPPARTMEqNTS:
Bu�ldin �Divi
Public Works
41Alk RA-
ire Prevention
Structural
(girt), ,V9,
arming Division
n
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
n
DUE DATE: 05-24 -12
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
No further Review Required
n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 06 -21 -12
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Prrer Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name WESTOWER COMMUNICATIONS INC UBI No. 601979870
Phone 4078521755 Status Active
Address 9961 Sidney Hayes Rd License No. WESTOCI975J8
Suite /Apt. License Type Construction Contractor
City Orlando Effective Date 4/28/2003
State FL Expiration Date 12/14/2012
Zip 32824 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SPECTNS983B2
SPECTRASITE
NETWORK SRVCS INC
Construction
Contractor
General
Unused
1/22/2002
12/7/2004
Archived
SPECTCI011RN
SPECTRASITE
CONSTRUCTION INC
Construction
Contractor
General
Unused
12/15/1999
12/7/2002
Archived
WESTOCI0770C
WESTOWER
COMMUNICATIONS INC
COMMUNIC
Construction
Contractor
General
Unused
9/3/1993
6/1/2000
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
PAYNE, CALVIN JAY
Director
03/07/2011
Amount
JARVIS, MIKE ARTHUR
President
01/26/2011
20ECS000527
CARR, MICHAEL DOUGLAS
Treasurer
01/26/2011
BARKER, J JOHN EDWARD
Vice President
01/26/2011
HARTFORD FIRE
INS CO
MARTIN ICH, MATTHEW
Vice President
08/04/2003
01/26/2011
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
HARTFORD FIRE
INSURANCE
52BSBAD6506
04/02/2003
Until Cancelled
$12,000.00
04/28/2003
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date,
Amount
Received Date
5
Hartford
Casualty Ins Co
20ECS000527
12/31/2011
12/31/2012
$1,000,000.00
01/13/2012
4
HARTFORD FIRE
INS CO
20ECSQU527
12/31/2007
12/31/2011
$1,000,000.00
12/20/2010
3
TWIN CITY FIRE
2QUENQUO522
12/31/2005
12/31/2007
$1,000,000.00
01/02/2007
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Printaspx
07/25/2012
PLANNING APPROVED •
No changes can be made. to thews
plans without approval from the
Planning Division of DCD
APProved Y.' r V i S_
D� `) (l— -
PROJECT CONSULTANTS:
VICINITY MAP
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
WA094
GENERAL LOCATION MAP
1-� :.� viii
��FCP:
��. %'�' .)chanica!
�..7 i c,rical
numbing
riKas Piping
C °7 of Tukwila
I"�I.4z°,;i " ..G DIVISION
P!^ r„ "iew approval is subject to errors and omissions.
c construction documents does not authonza
of any adopted code or ordinance. Receipt
rj L oVeci Meld (bpy a • r, i`. ns is acknowledged:
/1
By_
Date:
WESER
COMMUNICATIONS
PLANS PREPARED BY:
REVISIONS
No changes sha de to thy+ scope
of wort( without prior e,pprov J of
1\117777: i ,',ding Divi3i
air .;n-J rlil t';. i°J.Q
pir�
3 � �, a n�.�� �,iaa �A,s�n,;tfi,7I
a y i� „�� addf!ional
PROJECT INFORMATION
IM'ItlH.
APPLICANT:
AT &T MOBILITY CORPORATION
16221 NE 72nd WAY, RTC 3
P.O. BOX 97061
REDMOND, WA 98052
PROJECT ENGINEER:
CORNERSTONE ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD N.E. SUITE 210
WOODINVILLE, WA 98072
MARK W OLSON, P.E.
PH: (425) 487 -1732
FAX: (425) 487 -1734
DRIVING DIRECTIONS
FROM AT &T MOBILITY IN REDMOND:
HEADING WEST ON SR -520 WEST TOWARDS SEATTLE. TAKE THE 1 -405 SOUTH EXIT TOWARDS RENTON. TAKE THE SOUTHCENTER BLVD EXIT TOWARDS
SOUTHCENTER MALL. TURN RIGHT ON 61ST AVENUE S. TURN RIGHT ON SOUTHCENTER PKWY, ARRIVE AT 16500 SOUTHCENTER PKWY ON THE LEFT
CODE INFORMATION:
ZONING CLASSIFICATION: TUKWILA URBAN CENTER
BUILDING CODE: IBC 2009
CONSTRUCTION TYPE: TELECOMMUNICATIONS
OCCUPANCY: UNOCCUPIED
JURISDICTION: TUKWILA
PROPOSED BUILDING USE: TELECOMM
PROPERTY OWNER:
CHA SOUTHCENTER LLC
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
PROJECT CONSULTANTS:
WESTOWER COMMUNICATIONS, INC.
7525 SE 24TH ST, SUITE 500
MERCER ISLAND, WA 98040
SITE ACQUISITION:
HEATHER WASNICK
(918) 852 -0693
hwasn ick @westower.com
PROJECT MANAGER:
MARK RAINEY
(425) 306 -6865
m ra i n ey @wes tower. com
PERMITTING AGENT:
SUNNY AUSINK
(206) 342 -6390
sausink @ptswa.com
APPROVAL /SIGN OFF OF CONSTRUCTION DRAWINGS
CONSULTANT GROUP SIGN OFF DATE SIGNATURE AT &T SIGN OFF DATE SIGNATURE
CONSTRUCTION COORDINATOR RF ENGINEER
LANDLORD'S REPRESENTATIVE INTERCONNECT
PROJECT MANAGER OPERATIONS
SITE ACQUISITION COMPLIANCE
ZONING CONSTRUCTION MANAGER '
PROJECT MANAGER
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
SITE LOCATION: (BASED ON NAD 83)
LATITUDE: 47 °27'15.36" N (47.4542)
LONGITUDE: 122 °15'38.34" W (122.2606)
TOP OF STRUCTURE: 104.7' (BUILDING)
BASE OF STRUCTURE: 33.4' AMSL
PROJECT AREA:
60 SQ. FT.
GENERAL INFORMATION:
1. PARKING REQUIREMENTS ARE UNC
2. TRAFFIC IS UNAFFECTED.
3. NO SIGNAGE IS PROPOSED.
PARCEL NUMBER:
6437300020
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT &T
WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED.
PROJECT DESCRIPTION:
THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY, CONSISTING OF ADDING (1) BATTERY CABINET, AND (1)
RECTIFIER INTO AN EXISTING POWER CABINET MOUNTED ON A EXISTING EQUIPMENT
PLATFORM.
DRAWING INDEX
DWG. DESCRIPTION
NO.
T -1 TITLE SHEET
G -1 GENERAL NOTES
A -1 SITE PLAN
A -1.1 EXISTING & PROPOSED ENLARGED SITE PLANS
A -2 EXISTING & PROPOSED EAST ELEVATIONS
A -2.1 EXISTING & PROPOSED WEST ELEVATIONS
A -3 EQUIPMENT DETAILS
A -4 BATTERY SYSTEM REQUIREMENTS
E -1 ELECTRICAL SCHEMATIC
E -2 SCHEMATIC GROUNDING PLAN
E -3 ELECTRICAL & GROUNDING DETAILS
LEGAL DESCRIPTION
OUTBACK STEAK HOUSE -BSP
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012 ''..pp
Ai- lL
City of Tukwila
BUILDING DIVISION
Dig -i��►
_ CORNERSTONE ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @comerstone- engr.com
WWW.CORNERSTONE- ENGR.COM
PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
ISSUED FOR
._REV: =DATE:
CONSTRUCTION
ISSUED FOR:
Y:
'—DRAWN BY: — :
CURRENT ISSUE DATE
L 05-;
LICENSURE:
APV.:
LJS
JDG
MWO
CEI JOB NUMBER: 12 -13054
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
'—DRAWN BY: — :
CURRENT ISSUE DATE
L 05-;
LICENSURE:
APV.:
LJS
JDG
MWO
05-21-12
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
`DRAWING TITLE:
_DRAWING NUMBER:
TITLE SHEET
0
CEI JOB NUMBER: 12 -13054
GENERAL NOTES:
1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS
SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY,
UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL
INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS
DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND
OWNERS PROJECT MANUAL.
2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB
SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED
PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE
CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM
THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH
CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT /ENGINEER VERBALLY AND IN WRITING.
3. THE ARCHITECTS /ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE
CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK.
CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR
OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT
EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN
ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR
THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT /ENGINEER OF ANY
CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S
PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE
MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE.
4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES
FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE
LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
6. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN
STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,
RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL
AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL
CODES BEARING ON THE PERFORMANCE OF THE WORK.
7. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF
CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA
OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS
SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR
CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECTS SIGNED WET
STAMP.
8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE
NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE.
9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE
MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT
SITE.
10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT
LESS THAN 2 -A OR 2 -A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF
PROJECT AREA DURING CONSTRUCTION.
11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON
COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE
OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING
CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR
SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR
PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS,
DUST, OR SMUDGES OF ANY NATURE.
13. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED
WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED
BY THE CONSTRUCTION DRAWINGS /CONTRACT DOCUMENTS.
14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO
AVOID DISTURBING NORMAL BUSINESS.
15. THE CONTRACTOR SHALL PROVIDE AT &T WIRELESS, LLC. PROPER INSURANCE
CERTIFICATES NAMING AT &T WIRELESS, LLC. AS ADDITIONAL INSURED, AND AT &T
WIRELESS, LLC. PROOF OF LICENSE(S) AND PE & PD INSURANCE.
16. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL
INSPECTIONS.
17. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY
INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY
LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. DIAL 811
18. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND
SUBMIT TO AT &T WIRELESS, LLC. ALONG WITH REDLINED CONSTRUCTION SET.
19. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP
(REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET
TO AT &T WIRELESS, LLC. UPON COMPLETION.
20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR
PARTICIPATION IN BID WALK.
21. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER
COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION
COORDINATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT
CONSTRUCTION MANAGER AND ARCHITECT.
22. ANY SUBSTITUTIONS OF MATERIALS AND /OR EQUIPMENT, MUST BE APPROVED BY AT &T
CONSTRUCTION MANAGER.
23. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND /OR ANTENNA FRAMES
WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL
CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING
CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY
AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE
ROOFING CONTRACTORS WARRANTY FOR MOISTURE PENETRATION OR AND OTHER
FUTURE BREACH OF ROOFING INTEGRITY.
24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN
CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL
CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE
THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNATED EXISTING
EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR
SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP
CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED, THE CONTRACTOR
SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN
PHOTO SIMULATIONS. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL
CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO
FABRICATION AND CONSTRUCTION.
GENERAL NOTES (CONT'D):
25. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND /OR ANTENNA FRAMES WHERE
ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR
TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE
PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN
UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" - HAVING
INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL
REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE
PROVISIONS FOR X -RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE
ANCHORING OCCURS.
26. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL
CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP
TIES SHALL NOT BE PERMITTED FOR USE ON AT &T PROJECTS. RECOMMENDED MANUFACTURE
SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S -CP UNDER SERIES -304 (OR
EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA.
1.
DESIGN CRITERIA:
THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE 2009 WITH WASHINGTON STATE BUILDING CODE
AMENDMENTS (IBC 2009)
2. DESIGN LOADS:
DESIGN DATA FOR CITY OF TUKWILA, WA:
-ROOF SNOW LOAD
-BASIC WIND SPEED
-WIND EXPOSURE
25 psf
85 MPH (3 SEC GUST)
B
CODE COMPLIANCE:
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE
CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.
NOTHING ON THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE
CODES:
2009 INTERNATIONAL BUILDING CODE
2009 INTERNATIONAL MECHANICAL CODE
2009 NFPA 54 - NATIONAL FUEL GAS CODE
(PROPANE INSTALLATIONS ONLY)
2008 NFPA 58 - LIQUEFIED PETROLEUM GAS CODE
(PROPANE INSTALLATIONS ONLY)
LOCAL BUILDING CODE ORDINANCES
2009 WASHINGTON STATE ENERGY CODE
ICC /ANSI A117.1 -2006
2009 INTERNATIONAL EXISTING BUILDING CODE WITH STATE WIDE AMENDMENTS FOUND IN THE IBC
2009 INTERNATIONAL RESIDENTIAL CODE
2009 INTERNATIONAL FUEL GAS CODE
2009 INTERNATIONAL FIRE CODE
2009 UNIFORM PLUMBING CODE
2008 NFPA 70 NATIONAL ELECTRICAL CODE
2012 NATIONAL ELECTRIC SAFETY CODE
2009 ANSI / TIA / EIA - 222 - G
NFPA -101 - LIFE SAFETY CODE
CONCRETE NOTES:
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI -318.
2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE
WITH CHAPTER 19 OF THE IBC 2009. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL
BE AS FOLLOWS.
TYPE OF CONSTRUCTION
A. SLABS ON GRADE
TOPPING SLABS
CONCRETE PIERS
B. ALL STRUCTURAL CONCRETE
EXCEPT WALLS
C. CONCRETE WALLS
28 DAY STRENGTHS W/C
(f c) RATIO
2,400 PSI ' .45
4,000 PSI < .45
4,000 PSI .45
CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O.
MINIMUM CEMENT
CONTENT
PER CUBIC YARD
3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE
METHODS AND PROCEDURES OF CONCRETE PLACEMENT.
5 1/2 SACKS
6 1/2 SACKS
6 1/2 SACKS
4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE
AIR - ENTRAINED WITH AN AIR - ENTRAINING AGENT CONFORMING TO ASTM C260, C494,
C618, C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE
1904.2.1 OF THE IBC 2009.
5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1),
GRADE 60, fy= 60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE
DRAWINGS SHALL BE GRADE 40, fy= 40,000 PSI. GRADE 60 REINFORCING BARS INDICATED
ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING
COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY
REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN
A.W.S. D14 ARE SUBMITTED.
6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN
ACCORDANCE WITH AC1 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST
30 BAR DIAMETERS OR A MINIMUM OF 2' -0 ". PROVIDE CORNER BARS AT ALL WALL AND
FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A
MINIMUM OF 2' -0 ". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT
SIDES AND ENDS.
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -185.
8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60,
fy= 60,000 PSI.
9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT
UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT.
10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
- FOOTINGS AND OTHER UNFORMED
SURFACES, EARTH FACE
- FORMED SURFACES EXPOSED
TO EARTH OR WEATHER ( #6 BARS OR LARGER)
( #5 BARS OR SMALLER)
- SLABS AND WALLS (INTERIOR FACE)
11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS.
12. ANCHOR BOLTS TO CONFORM TO ASTM A307.
3"
2"
1 1/2"
3/4"
13. NON - SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND
SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE
MATERIAL ON WHICH IT IS PLACED (3,000 PSI MINIMUM).
14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING
TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER.
STRUCTURAL STEEL NOTES:
1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT
FOR REVIEW PRIOR TO FABRICATION.
2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING,
HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION
ANCHORS) SHALL BE BASED ON THE A.I.S.I. "SPECIFICATION FOR THE DESIGN,
FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION.
SUPERVISION SHALL BE IN ACCORDANCE WITH IBC 2009 CHAPTER 22, BY A QUALIFIED
TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE
FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS.
3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER
A. WIDE FLANGE SHAPE
B. OTHER SHAPE, PLATES AND ROD
C. PIPE COLUMNS
D. STRUCTURAL TUBING
E. ANCHOR BOLTS
F. CONNECTION BOLTS
ASTM A992, Fy 50 KSI
ASTM A36, Fy 36 KSI
ASTM A53, Fy 35 KSI
ASTM A500, Fy 46 KSI
ASTM A307
ASTM A325
4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M -00.
5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.I. AND AWS STANDARDS AND SHALL
BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY
PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE 60
REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN
ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE
PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN
REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL
REQUIREMENTS OF WELDED BARS.
6. COLD - FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE
SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL
COLD - FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.I. "SPECIFICATION FOR THE
DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS."
7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" DIA.) AND SHALL
HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE.
8. NON - STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A307
BOLTS UNLESS NOTED OTHERWISE.
9. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN &
CONSTRUCTION SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED
OTHERWISE.
10. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE.
11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH
PAINT) OR APPROVED EQUAL.
TOWER /POLE NOTES:
1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA
LOADING IS TO BE DONE BY OTHERS.
2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL AND
FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE
CENTERS SUITABLE TO THE MANUFACTURERS REQUIREMENTS.
ABBREVIATED ROOF TOP SAFETY PROCEDURES
(WHEN APPLICABLE):
(AS PER "ACCIDENT PREVENTION PROGRAM" - BY PERMISSION OF WREN CONSTRUCTION,
INC. - 03/01/99)
FALL PROTECTION METHODS AND EQUIPMENT
ROOF TOP INSTALLATIONS
1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE,
THE CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR
TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION
WORKERS.
2. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E.,
BACKING UP TOWARD A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFETY
MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUAL AND VERBAL
DISTANCE OF THE CONSTRUCTION WORKERS.
3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN
UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE.
4. SAFETY LINE SHALL BE MINIMUM %z" DIAMETER NYLON, WITH A NOMINAL TENSILE
STRENGTH OF 5400 LBS.
5. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE
STRUCTURE.
6. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO
REACH EDGE OF ROOF, BUT NOT BEYOND.
7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS.
8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION
EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES,
INCLUDING:
INSPECTION OF CONSTRUCTION AREA FOR HAZARDS
USE OF AN INSPECTION CHECKLIST
INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS
REPORTING AND DOCUMENTING ANY HAZARDS
REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION
POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN
RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER
COWORKER SAFETY REPRESENTATIVE
REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL
NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION
REFERENCED OSHA REGULATION /STANDARDS SHALL BE REVIEWED BY TOWER
ERECTORS,
EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS /SUBCONTRACTORS
29 CFR 1926.500 - SCOPE, APPLICATION, AND DEFINITIONS
29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION
19 CFR 1926.502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
SYMBOLS AND ABBREVIATIONS
A/C AIR CONDITIONING
AGL ABOVE GRADE LEVEL
APPROX APPROXIMATELY
BLDG
BLK
CLG
CLR
CONC
CONST
CONT
DBL
DIA
DIAG
DN
DET
DWG
EA
EL
ELEC
EQ
EQUIP
EXT
FIN
FLUOR
FLR
FT
GA
GALV
GC
GRND
GYP BD
HORZ
HR
HT
HVAC
ID
IN
INFO
INSUL
INT
IBC
BUILDING
BLOCKING
CEILING
CLEAR
CONCRETE
CONSTRUCTION
CONTINUOUS
DOUBLE
DIAMETER
DIAGONAL
DOWN
DETAIL
DRAWING
EACH
ELEVATION
ELECTRICAL
EQUAL
EQUIPMENT
EXTERIOR
FINISH
FLUORESCENT
FLOOR
FOOT
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GROUND
GYPSUM WALL BOARD
HORIZONTAL
HOUR
HEIGHT
HEATING
VENTILATION
AIR CONDITIONING
INSIDE DIAMETER
INCH
INFORMATION
INSULATION
INTERIOR
INTERNATIONAL
BUILDING CODE
T
P
T
P
COAX COAX
(E)
LBS POUNDS
MAX
MECH
MTL
MFR
MGR
MIN
MISC
NA
NIC
NTS
MAXIMUM
MECHANICAL
METAL
MANUFACTURE
MANAGER
MINIMUM
MISCELLANEOUS
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
PLYWD
PROJ
PROP
PT
REQ
RM
RO
SHT
SIM
SPEC
SF
SS
STL
STRUCT
STD
SUSP
THRU
TNNG
TYP
PLYWOOD
PROJECT
PROPERTY
PRESSURE TREATED
REQUIRED
ROOM
ROUGH OPENING
SHEET
SIMILAR
SPECIFICATION
SQUARE FOOT
STAINLESS STEEL
STEEL
STRUCTURAL
STUD
SUSPENDED
THROUGH
TINNED
TYPICAL
UNO UNLESS NOTED
OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W/
W/O
WP
WITH
WITHOUT
WATER PROOF
TELEPHONE
POWER
GROUND WIRE
COAXIAL CABLE
ANTENNA
CENTERLINE
EXISTING
DETAIL NUMBER
SHEET NUMBER
SPECIAL INSPECTIONS:
SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2009 SECTION 1704.
SOILS /GEOTECHNICAL:
❑ SHORING INSTALLATION AND MONITORING
❑ OBSERVE AND MONITOR EXCAVATION
❑VERIFY SOIL BEARING psf BEARING
❑SUBSURFACE DRAINAGE PLACEMENT
❑VERIFY FILL MATERIAL AND COMPACTION
❑VERIFY CONDITIONS AS ANTICIPATED
❑ PILE PLACEMENT (AUGER CAST /DRIVEN PILE)
D OTHER
REINFORCED CONCRETE:
❑REINFORCING STEEL AND CONCRETE PLACEMENT
❑ PRESTRESSED /PRECAST CONCRETE FABRICATION AND ERECTION
❑BATCH PLANT INSPECTION
❑ SHOTCRETE
❑ GROUTING
D OTHER
STRUCTURAL STEEL:
i
❑ FABRICATION AND SHOP WELDS
❑ ERECTION AND FIELD WELDS AND BOLTING
DOTHER
STRUCTURAL ALUMINUM:
❑FABRICATION AND SHOP WELDS
❑ERECTION AND FIELD WELDS AND BOLTING
DOTHER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
STRUCTURAL MASONRY:
❑CONTINUOUS
:PERIODIC
❑
OTHER:
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
ANCHORING TO CONCRETE:
❑ BOLTS INSTALLED IN CONCRETE RECEIVED
❑POST- INSTALLATION ADHESIVE ANCHORS MAY 23 2012
❑ POST- INSTALLATION MECHANICAL ANCHORS
PERMIT CENTER
PROJECT CONSULTANTS:
_ PLANS PREPARED BY:
WES TOWER
COMMUNICAT IONS
_ ,_jCORNERSTONE
ENGINEERING. INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone -engr.com
WWW.CORNERSTONE- ENGR.COM
=PROJECT INFO
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR-
-REV: =DATE: ISSUED FOR:
CONSTRUCTION
Y:
CHK..
-DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
APV.:
LJS
1 JDG
I MWO
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
CHK..
-DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
APV.:
LJS
1 JDG
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
-DRAWING TITLE:
_DRAWING NUMBER:
GENERAL NOTES
G.1
CEI JOB NUMBER: 12 -13054
THIS IS NOT A SURVEY
ALL INFORMATION AND TRUE NORTH
HAVE BEEN OBTAINED FROM EXISTING
DRAWINGS AND ARE APPROXIMATE.
1
1
\
1
1
1
1
TL# 5379200290
TL# 5379200282
ADJACENT ZONING
ZONE:
TUC
TL# 5379200300
1
1
SOUTHCENTER PKWY
1
1
1
1
1
1
TL# 2623049021
PROPERTY LINE 255.51'±
N89 °45'58 "W
ASPHALT
PARKING
PROPERTY LINE 197.67'±
N89 °45'58 "W
1
TL# 2623049104
ADJACENT ZONING
ZONE:
TUC
±I
ti
0
`4"I
w
IM
W LO
Z to
J N
>_ o
I— 0
o
w
al
°el
0_
--
1
TL# 2623049102
1
PROPERTY LINE 350'±
S89° 45' 58" E
ASPHALT
PARKING
1
1
(E) NATIVE GRASS
-1-I I I I `i ..1- ►r l I VI 1 i- 11.1,1 I
TL# 6437300020
291,927 SQ. FT.
6.7 ACRES
1111111111111111111-1-
(E)
BUILDING
F11 1 11111111111111 11 1-
TL#
2623049137
(E)
BUILDING
1
111111 1 1 1 1111111�
11 111111111111fi
ASPHALT
PARKING
PROPERTY LINE 407.84'±
S89° 45' 58" E
ADJACENT ZONING
ZONE:
TUC
TL# 2623049128
-
(E) TREE
(TYP)
TL# 2623049005
ADJACENT ZONING
ZONE:
TUC
1
TL# 2623049062
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 232012
PERMIT CENTER
PLAN NORTH
SITE PLAN
22x34 SCALE: 1" = 50' -0" 111x17 SCALE: 1" = 100' -0"
1
- PROJECT CONSULTANTS:
WES TOWER
COMMUNICATIONS
_ PLANS PREPARED BY:
_�E CORNERS -TONE
ENGINEERING, I N C .
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone- engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR: _ REV: =DATE:
CONSTRUCTION
ISSUED FOR
-DRAWN BY:
CURRENT ISSUE DATE:
LICENSURE:
CHK.: APV.:
I
LJS
CEI JOB NUMBER: 12 -13054
I JDG
I MWO
I
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
-DRAWN BY:
CURRENT ISSUE DATE:
LICENSURE:
CHK.: APV.:
I
LJS
CEI JOB NUMBER: 12 -13054
I JDG
I MWO
I
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
-DRAWING TITLE:
SITE PLAN
NUMBER.
A-1
0
CEI JOB NUMBER: 12 -13054
W
PROPOSED
ARGUS TE40
BATTERY CABINET
4
A -3
PROPOSED L4x4x1/4
..y
1'
J:
1,
111111111111111111111111
CV
0
N
111111111111111111111111111111111 11111 11
1111111111111111111111
111
11 &1 111 1111111111111111111111111
(E) NOKIA
CABINET
(E) NOKIA
CABINET
(E) UMTS
CABINET
_ ____m_u_m_ • III11
lumil U. 1hrtrari :.. 1 •
misommummaingi
1IiiII1IIJ
rplummunummusi _ 1IuIflhIi1I11ii Ui I!11�®III UiiIiiP -
iIUIfIIIIE1_i IiHI ;1iiI1FOiff uI II11iiLiIi
1 ��i�illE1�� IIIH`I.11111i!; ° �� L! 1II!�i!
-'1
I
NEWEEMI -- MEE -111- 11"
(E)
TE40
BATTERY
CABINET
'4/
111111111111111111111111 1111111111111111111111111111111111111111111111111111 11111111111111[11 11111111111111 111 111111111111
(E)
TE21
POWER
CABINET
(E)
TE40
BATTERY
CABINET
(E) E EQUIPMENT
PLATFORM
-
(E) HOFFMAN BOX
19' -8"
27' -9"
(E) ROOF MOUNTED
COAX CABLE TRAY
ADD (1) RECTIFIER IN (E)
ARGUS POWER CABINET
(E) SERVICE LIGHT
(E) TELCO BOX
(E) SERVICE PANEL
(E) XFMR
PLAN NORTH
CV
0
N
(E) NOKIA
CABINET
(E) NOKIA
CABINET
1
(E) UMTS
CABINET
(E) EQUIPMENT
PLATFORM
(E)
TE43
CABINET
(E)
TE40
BATTERY
CABINET
+t; ENE
11 11 HININE11111101001ii
11 LEIMMIEFinal
} -f -f
f _ f
1
(E)
TE21
POWER
CABINET
(E)
TE40
BATTERY
CABINET
see
(E) HOFFMAN BOX
19' -8"
27' -9"
(E) ROOF MOUNTED
COAX CABLE TRAY
pyL-t1H
(E) SERVICE LIGHT
(E) TELCO BOX
(E) SERVICE PANEL
(E) XFMR
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 232012
PERMIT CENTER
PLAN NORTH
PROPOSED ENLARGED SITE PLAN
22x34 SCALE: 3/8" = V-0" 111x17 SCALE: 3/16" = 1' -0"
EXISTING ENLARGED SITE PLAN
22x34 SCALE: 3/8" = 1' -0"
111x17 SCALE: 3/16" = 1' -0"
at &t
Your world. Delivered.
= PROJECT CONSULTANTS:
WES TOWER
COMMUNICATIONS
PLANS PREPARED BY:
4 -. CORNERS -a-ONE
ENGINEERING. INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
ISSUED FOR: _REV:: DATE:
CONSTRUCTION
ISSUED FOR:
Y:
CHK.:
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
APV.:
LJS
1
I JDG
CEI JOB NUMBER:
I MWO
A
05 -21 -12
PERMIT
LJS
e
05 -04 -12
CLIENT REVIEW
LJS
CHK.:
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
APV.:
LJS
1
I JDG
CEI JOB NUMBER:
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
— DRAWING TITLE:
EXISTING & PROPOSED
ENLARGED SITE PLANS
- DRAWING NUMBER:
A-1 •
1
0
CEI JOB NUMBER:
12 -13054
(E) ANTENNA MOUNT
TOP OF (E) ANTENNA ARRAY
-CDA..
PROPOSED ARGUS
TE40 BATTERY CABINET
(E) ARGUS TE21
POWER CABINET
(E) ARGUS TE40
BATTERY CABINET
EL 97' -2 "±
TOP OF PENTHOUSE
EL 96' -4 "±
TOP OF (E) PARAPET AL
EL 82' -6 "±
TOP OF (E) GRATING AL
EL 78' -3 "±
TOP OF (E) ROOF AL
EL 76' -0 "±
GRADE
EL 0' -0" (ASSUMED)
PROPOSED EAST ELEVATION
22x34 SCALE: 3/32" = 1' -0"
111x17 SCALE: 3/64" = 1' -0"
2
(E) ANTENNA MOUNT
TOP OF (E) ANTENNA ARRAY
J \
.— - - --
(E) NOKIA CABINET (BEYOND)
(E) UMTS CABINET
(E) ARGUS TE21
POWER CABINET
EL 97' -2 "±
TOP OF PENTHOUSE Akk
EL 96' -4 "±
TOP OF (E) PARAPET
EL 82' -6 "±
TOP OF (E) GRATING AL
EL 78' -3 "±
TOP OF (E) ROOF AL
EL 76' -0 "±
REVIEW,: D FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 232012
PERMIT CENTER
GRADE
EL 0' -0" (ASSUMED)
EXISTING EAST ELEVATION
22x34 SCALE: 3/32" = 1' -0"
111x17 SCALE: 3/64" =11-0"
at&t
Your world. Delivered.
PROJECT CONSULTANTS:
— PLANS PREPARED BY:
WES TOWER
COMMUNICATIONS
_E CORNERSTONE ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
— ISSUED FOR:
_REV: =DATE: — ISSUED FOR:
CONSTRUCTION
J
BY. .
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
1
JDG
I MWO
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
1
JDG
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
_DRAWING NUMBER:
EXISTING & PROPOSED
EAST ELEVATIONS
A.2
0
CEI JOB NUMBER: 12 -13054
TOP OF (E) ANTENNA ARRAY
WV EL 97' -2 "±
TOP OF PENTHOUSE
EL 96' -4 "±
TOP OF (E) PARAPET
EL 82' -6 "±
ATOP OF (E) GRATING
EL 78' -3 "±
TOP OF (E) ROOF
PROPOSED ARGUS
TE40 BATTERY CABINET
EL 76' -0 "±
jiik GRADE
EL 0'-0" (ASSUMED)
(E) NOKIA CABINET
(E) ANTENNA MOUNT
PROPOSED WEST ELEVATION
22x34 SCALE: 3/32" = 1' -0" 111x17 SCALE: 3/64" = 1' -0"
2
TOP OF (E) ANTENNA ARRAY
EL 97' -2 "±
TOP OF PENTHOUSE
EL 96' -4 "±
�j TOP OF (E) PARAPET
(E) ARGUS TE21 POWER
CABINET (BEYOND)
LJ
(E) ANTENNA MOUNT
112 -11
EL 82' -6 "±
TOP OF (E) GRATING
MY EL 78' -3 "±
ilk TOP OF (E) ROOF
MY EL 76' -0 "±
jik GRADE
EL 0' -0" (ASSUMED)
(E) NOKIA CABINET
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 232012
PERMIT CENTER
EXISTING WEST ELEVATION
22x34 SCALE: 3/32" = 1' -0" 111x17 SCALE: 3/64" =
1
= PROJECT CONSULTANTS:
WES I OWER
COMMUNICATIONS
= PLANS PREPARED BY:
_ CORNERSTONE
ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @comerstone- engr.com
WWW.CORNERSTONE - ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
– ISSUED FOR-
-REV: =DATE:
CONSTRUCTION
ISSUED FOR:
—DRAWN BY:
CURRENT ISSUE DATE:
LICENSURE:
CHK. • APV.:
LJS
0
I JDG
I MWO
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
—DRAWN BY:
CURRENT ISSUE DATE:
LICENSURE:
CHK. • APV.:
LJS
0
I JDG
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
-DRAWING TITLE:
DRAWING NUMBER:
EXISTING & PROPOSED
WEST ELEVATIONS
A-2.1
0
CEI JOB NUMBER: 12 -13054
INTERNAL
BUSS BAR
CABINET GROUND
WIRE STUDS
2' -6"
2' -0"
N
CV
0
0
0
0
0
0
0
O
CV
N
N
O
ti
RIGHT SIDE VIEW
5/8 "0 HOLES (TYP OF 4)
DRILL AND INSTALL
ANCHOR BOLTS PER
MANUFACTURER'S
RECOMMENDATIONS
OR APPROVED EQUAL
1.10"
BATTERY CABINET DIMENSIONS
MANUFACTURER
ARGUS TE40
HEIGHT
84"
DEPTH
30"
WIDTH
30"
WEIGHT
3200 LBS
30.0"
ENCLOSURE DIMS
27.80"
1.10"
O
tri
FRONT
MOUNTING HOLE
LOCATION
ENCLOSURE DIMS
ARGUS TE40 CABINET
(E) STEEL GRATING
(E) W -BEAM, TYP
...
NOTES:
1. PLACE L4x4 SUPPORTS TO SUIT EQUIPMENT
CABINET ANCHOR BOLT SPACING
2. FOR DESIGN OF THESE CONNECTIONS, PLEASE
REFERENCE THE SUPPORTING STRUCTURAL
CALCULATIONS BY CEI DATED 05/04/12
1/2"0 A307 BOLT
(TYP OF 4 PER CABINET)
(2) L4x4x1/4x0' -3" CUT ANGLE
W/ (1) 5/8 "0 BOLT THRU @ 2 1/4" GAUGE
OUTSTANDING LEG (TYP) & (2) 5/8 "0 A307
BOLT TO (E) W -BEAM W/ FIELD DRILL
L4x4x 1 /4
w
w
2"
TYP
±2' -6 3/4"
V.I.F.
(E) W -BEAM (BEYOND)
ARGUS TE40 BATTERY CABINET (24 V)
22x34 SCALE: 1" = 1-0" 111x17 SCALE: 1/2" = 1' -0"
4
SUPPORT ANGLE DETAIL
22x34 SCALE: 1 1/2" = 1' -0"
111x17 SCALE: 3/4" = 1' -0"
3
REVIEWED FOR
CODE COMPLIANCE
CE
A
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
ECEIVEr
MAY 2 3 2012
PERMIT CENTth
NOT USED
22x34 SCALE: NTS 111x17 SCALE: NTS
2
NOT USED
22x34 SCALE: NTS
111x17 SCALE: NTS
1
= PROJECT CONSULTANTS:
WES TOWER
COMMUNICATIONS
= PLANS PREPARED BY:
CORNER 51GONE
n
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO.
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
ISSUED FOR:
_ REV: = DATE:
CONSTRUCTION
ISSUED FOR:
—DRAWN BY
CURRENT ISSUE DATE:
LICENSURE:
CHK.:
APV.:
I
LJS
I
JDG
I MWO
I
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
—DRAWN BY
CURRENT ISSUE DATE:
LICENSURE:
CHK.:
APV.:
I
LJS
I
JDG
I MWO
I
05 -21 -12
=DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
-DRAWING TITLE:
LDRAWIN NUMBER:
EQUIPMENT DETAILS
A-3
0
CEI JOB NUMBER: 12 -13054
PROJECT BATTERY SYSTEM DATA
BATTERY TYPE
VALVE REGULATED LEAD ACID (VRLA)
NO. OF BATTERIES
20 (8 EXISTING & 12 PROPOSED)
BATTERY
MANUFACTURER
EXCIDE TECHNOLOGIES INDUSTRIAL ENERGY
MODEL NO.
MARATHON M12V155FT
DIMENSIONS
22.0" D x 4.9" W x 11.15" H
WEIGHT
119 Ibs PER UNIT
# OF CELLS PER UNIT
SPECIFIC GRAVITY
LEAD WEIGHT PER CELL
(Ibs)
ELECTROLYTE WEIGHT
PER CELL (Ibs)
ELECTROLYTE VOLUME
PER CELL (GAL)
ELECTROLYTE VOLUME
TOTAL (GAL)
1
1.35
90.4
21.4
2.17
43.40
BATTERY PLACEMENT:
CSA/UL, TYPE 3R RATED, SELF - CONTAINED ENCLOSURE CABINET WITH ENVIRONMENTAL CONTROLS. ALPHA TECHNOLOGIES, LTD
(20) BATTERIES PER CABINET.
SHELF MOUNTED WITHIN
MODEL# TE40B, MAX CAPACITY
BATTERY REQUIREMENTS
REQUIREMENTS
NONRECOMBINANT BATTERIES
RECOMBINANT BATTERIES
FLOODED LEAD
ACID BATTERIES
FLOODED NICKEL - CADMIUM
(Ni -Cd) BATTERIES
VALVE REGULATED
LEAD ACID (VRLA) BATTERIES
LITHIUM -ION BATTERIES
SAFETY CAPS
N/A
N/A
(608.2.2)
N/A
COMMENTS: PER MANUFACTURER, THE MARATHON M12V155FT UTILIZES A COMBINATION FLAME ARRESTOR / VENT CAP.
THERMAL RUNAWAY
MANAGEMENT
N/A
N/A
(608.3)
N/A
COMMENTS: BATTERY IS MORE RESILIENT AS A RESULT OF THE LOW SPECIFIC GRAVITY DESIGN HOWEVER, ADDITIONAL DC POWER PLANT TEMPERATURE COMPENSATION MAY BE
REQUIRED BY JURISDICTION. THERMAL RUNAWAY PROCEDURE ACTION SIGNAGE SHALL BE POSTED FOR EASY ACCESS IN ALL BATTERY AREAS.
SPILL CONTROL
N/A
N/A
(N /A)
N/A
COMMENTS: SPILL CONTROL NOT REQUIRED BY IFC FOR THIS TYPE OF BATTERY.
NEUTRALIZATION
N/A
N/A
v
(608.5.2)
N/A
COMMENTS: TOTAL ELECTROLYTE VOLUME IS UNDER REQUIRED SPILL CONTROL THRESHOLD, THEREFORE NO NEUTRALIZATION MEASURES REQUIRED.
VENTILATION
N/A
N/A
(608.6.1;608.6.2)
N/A
COMMENTS: CONTINUOUS VENTILATION SHALL BE PROVIDED AT A RATE OF NOT LESS THAN 1 CUBIC FOOT PER MINUTE PER SQUARE FOOT (1 ft3 /MIN/ft2)
AS NOTED IN IFC 608.6.1 NO. 2. ENVIRONMENTAL CONTROLS ASSOCIATED WITH PROPOSED ENCLOSURE HAVE BEEN SHOWN TO MEET REQUIRED CODE REQUIREMENTS.
SIGNAGE
N/A
N/A
Al
v
(608.7)
N/A
COMMENTS: CODE SPECIFIED BATTERY ROOM SAFETY SIGNAGE, HAZARDOUS MATERIAL SIGNAGE (4 DIAMOND) AND THERMAL RUNAWAY PROCEDURE SIGNAGE SHALL ALL BE
CLEARLY POSTED IN ALL BATTERY AREAS.
SEISMIC PROTECTION
N/A
N/A
-\/
(608.8)
N/A
COMMENTS: BATTERY STORAGE ENCLOSURE CABINETS AND ANCHORAGE ARE DESIGNED TO EXCEED ALL IBC CODE REQUIRED SEISMIC FORCES FOR SITE SPECIFIC INSTALLATIONS.
SMOKE DETECTION
N/A
N/A
(608.9)
N/A
COMMENTS: N/A OUTDOOR APPLICATION
NOTE: CODE REFERENCES ARE TO 2009 INTERNATIONAL FIRE CODE FOR STATIONARY STORAGE BATTERY SYSTEMS.
CHEMICAL HAZARD
IDENTIFICATION SYSTEM
SPECIFIC
HAZARD
OXIDIZER
ACID
ALKALI
CORROSIVE
USE NO WATER
RADIATION HAZARD
OXY
ACID
ALK
COR
w
Y
REACTIVITY
4 - MAY DETONATE
3 SHOCK & HEAT
MAY DETONATE`
2 - VIOLENT CHEMICAL
CHANGES
1 - UNSTABLE IF HEATED
0 -STABLE
_}
BATTERY HAZ MAT SIGN
22x34 SCALE: NTS
111x17 SCALE: NTS
3
THIS ROOM CONTAINS:
LEAD -ACID BATTERY SYSTEMS,
CORROSIVE LIQUIDS (ELECTROLYTE),
ENERGIZED ELECTRICAL CIRCUITS,
AND HYDROGEN GAS
AUTHORIZED PERSONNEL ONLY
EYE PROTECTION REQUIRED
NO SMOKING OR OPEN FLAMES
BATTERY ROOM
rILJ
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 0 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
MAY 2 3 2012
PERMIT CENTER
BATTERY SYSTEM INFORMATION
22x34 SCALE: NTS
I11x17 SCALE: NTS
2
BATTERY DANGER SIGN
22x34 SCALE: NTS
111x17 SCALE: NTS
1
at &t
Your world. Delivered.
— PROJECT CONSULTANTS:
—PLANS PREPARED BY:
WES TOWER
COMMUNICATIONS
4 C CORNERS GONE ENGINEERIN, INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
PROJECT INFO.
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR:
_REV:: DATE:
CONSTRUCTION
ISSUED FOR:
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV
LJS
I JDG
I MWO
e
05 -21 -12
PERMIT
LJS
e
05 -04 -12
CLIENT REVIEW
LJS
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV
LJS
I JDG
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
"DRAWING TITLE:
DRAWING NUMBER:
BATTERY SYSTEM
REQUIREMENTS
A.4
CEI JOB NUMBER: 12 -13054
at &t
Your world. Delivered.
=PROJECT CONSULTANTS:
WES TOWER
COMMUNICATIONS
=PLANS PREPARED BY:
_• CORNERS -TONE
ENGINEERING, INC.
16928 WOODINVILLE- REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR:
—REV: =DATE:
CONSTRUCTION
ISSUED FOR:
Y:_
ELECTRICAL SPECIFICATION:
I JDG
111
l l l ► ► ► ► I I mil I I I I I m i l l 1 l l l l l l l l l l l l I l l l l ► t t t t l l l l l l ► I I I I I I I I I ► I I I I I I l i l l l l l l l t l t t t t l l l l l l l l l l l l l l ► I I I I I I I I ► ► I I I I I I I ► I I I I I I I I I IIIIIIIIIIIIIIIIIIIIIIIIIIII IIIlII H I►II II I►LI 111 I
IIIIIIIIII
1. COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL
BUILDING CODE, THE REQUIREMENTS OF ALL APPLICABLE
MUNICIPAL AND STATE CODES AND REGULATIONS, AND UTILITY
GUIDELINES.
2. PERFORM ALL VERIFICATION, OBSERVATIONS, TESTING AND
EXAMINATION OF WORK PRIOR TO THE ORDERING OF ELECTRICAL
EQUIPMENT AND THE ACTUAL CONSTRUCTION. ISSUE A WRITTEN
NOTICE OF ALL FINDINGS TO THE CONSTRUCTION MANAGER
LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND
DISCREPANCIES.
3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE
CONDUIT: SCHEDULE 40 CONFORMING TO UL ARTICLE 651:
WESTERN PLASTICS OR CARBON MANUFACTURER. COUPLINGS
SHALL BE SLIP -ON SOLVENT SEALED T -PIPE: SOLVENT, WESTERN
TYPE COMPATIBLE WITH PVC DUCT, ALL BENDS SHALL BE 30"
MINIMUM RADIUS.
4. NEUTRAL SHALL BE COLOR CODED, INSULATION SHALL BE
CROSS - LINKED POLYETHYLENE.
5. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF
SERVICES. SERVICE LOCATIONS TO BE
CONFIRMED PRIOR TO CONSTRUCTION.
fi. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING,
AND FEES IN CONJUNCTION WITH THE PROJECT.
7. THE CONTRACTOR TOR SHALL SCHEDULE ALL NECESSARY
INSPECTIONS WITH THE PROPER AUTHORITIES AND INFORM AT &T
24 HOURS IN ADVANCE. ALL TICKETS AND INSPECTION
OWNER'S
TTE D TO THE W S
VERIFICATIONS WILL BE SUBMI O O
R AFTER THE INSPECTION HAS
REPRESENTATIVE WITHIN 24-HOURS
TAKEN PLACE.
8. ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL
9. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED
JOURNEYMEN AND PERFORMED IN A WORKMANLIKE MANNER AND
SHALL PROCEED IN AN ORDERLY MANNER SO AS NOT TO HOLD UP
THE PROGRESS OF THE PROJECT.
10. THOROUGHLY TEST ALL LINES, FEEDERS, EQUIPMENT, AND
DEVICES WITH MAXIMUM LOADS TO ASSURE PROPER OPERATION
11. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM
TERMINATION TO TERMINATION WITHOUT SPLICES
12. PROVIDE PULL BOXES WHERE SHOWN AND /OR WHERE REQUIRED
BY CODES AND /OR UTILITY COMPANIES.
13. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE
MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS,
CONTRACTOR SHALL VERIFY ALL LOCATIONS.
14. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J- BOXES,
EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC
TAGS.
15. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE
WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER.
16. ALL FIRE RATED WALL AND FLOOR PENETRATIONS ARE TO BE
CAULKED AND SEALED WITH A FIRE RESISTANT CAULKING TO
MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION.
17. UTILIZE SONNEBORN TYPE NP -1 CAULKING FOR SEALING ALL
EXTERIOR WALL PENETRATIONS
0
O
A
(E) EQUIPMENT PLATFORM
PROPOSED 2 1/2 "0 RIGID DC POWER
CONDUIT MOUNTED ON UNDERSIDE OF
(E) PLATFORM (1) PER BATTERY
CABINET
PROPOSED 1"0 RIGID AC POWER
CONDUIT MOUNTED ON UNDERSIDE
OF (E) PLATFORM FROM UTILITY
PERMIT
P P P P P P P
A
05 -04 -12
CLIENT REVIEW
P P P P P P P
PROPOSED
ARGUS
TE40
BATTERY
CABINET
o�
lal
°
°
° =
° _
°
N
(E) TE40
BATTERY
CABINET
( E) UMTS
CABINET
n�
`1
I
\
°
(E) NOKIA
CABINET
■
■
-.
\
I
/
(E)
TE21
POWER
CABINET
(E) NOKIA
CABINET
-
(E) TE40
BATTERY
CABINET
f
ri,
�1
���
H -FRAME TO BATTERY CABINET (1)
PER BATTERY CABINET
_� =� ==
-
•
��
�'=
�II
�Mil
—.....
.+ _
------------
-;._- .;________,__
;..
. 1 TE43
CABINET
—
��_.--
= ==
•
- - -- -- • - - - --
,- ,.....-
NM
_.___�
- -•
NIE
-- - - ---
--
: - -
--�p._..-
-- - f -:
-- �
- - -- -- - --
-} • -•:-
-- - - -
_._� :
- - - ..._ .
-- ---_..
- -- -- -- - - - -- - - - -- } - - -
- ._.:.-
� - -: --
--- � - - - - -: - - -- -�
••}
YI
a
ENE
I
EISMIEM
f
1:11111=1=1111=211IN
--
MIMMIMMI
____'m'_____E'��p,:e
+
in
•
O
Wffl'
= = == =-=__
= ::: -_
iiiii,
(E) SERVICE PANEL
--)c)
3°.
XX'
v
ple•)_:..., 1 Ili
PLAN NORTH
/�
ELECTRICAL SCHEMATIC
3
22x34 SCALE: NTS
11x17 SCALE: NTS
FLEX CONDUIT, TYP
(E)
(E) ELECTRICAL SERVICE
PANEL / DISCONNECT
(E) ARGUS
TE40
BATTERY
CABINET
(E) ARGUS
TE21
POWER
CABINET
1
i
i
(E) ARGUS
TE40
BATTERY
CABINET
(E) TE43
CABINET
1 (. 1
(E) UMTS
° °
CABINET
a °
°
PROPOSED
(E) TELCO NIU
(E) XFMR \
o
(E) NOKIA
CABINET
(E) NOKIA
CABINET
M
ARGUS
TE40
_
_
BATTERY
CABINET
-
=
EED
I
a
_---
�ti�
■k
-■
,
:
.
I
�p
i s
----�
Y
8
. W
• •
■■
ROOFTOP 5 ___-
,J ,,
(E) POWER & TELCO PROPOSED FLEX CONDUIT, TYP
SERVICE
PROPOSED BURIED 1 "0 RIGID AC
POWER CONDUIT FROM UTILITY (E) EQUIPMENT PLATFORM
H -FRAME TO BATTERY CABINET
(1) TO EACH BATTERY CABINET
SEPA
PROPOSED UNDER PLATFORM MOUNTED PENMrE
2 1/2"0 RIGID DC POWER CONDUIT APP AND
RkQVOVAC �;,
ECEIE
MAY 2 3 ? ^41
PERMIT Cboi I t=ry
(1) TO EACH BATTERY CABINET
CEO 4:
ELECTRICAL SPECIFICATIONS
2
POWER RISER SCHEMATIC
22x34 SCALE: NTS
111x17 SCALE: NTS
22x34 SCALE: NTS 111x17 SCALE: NTS
at &t
Your world. Delivered.
=PROJECT CONSULTANTS:
WES TOWER
COMMUNICATIONS
=PLANS PREPARED BY:
_• CORNERS -TONE
ENGINEERING, INC.
16928 WOODINVILLE- REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR:
—REV: =DATE:
CONSTRUCTION
ISSUED FOR:
Y:_
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
0
I JDG
I MWO
ow 1
CEI JOB NUMBER: 12 -13054
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
—DRAWN BY:
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
0
I JDG
I MWO
05 -21 -12
= DRAWING INFORMATION.
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
-DRAWING TITLE:
DRAWING NUMBER-
ELECTRICAL SCHEMATIC
0
ow 1
CEI JOB NUMBER: 12 -13054
NOTE:
ALL GROUNDING WIRE RUNS AND
CONNECTIONS, BOTH ABOVE AND
BELOW GRADE, SHALL BE LOCATED
INSIDE OF THE LEASE AREA LINE.
GROUNDING KEYED NOTES
(E) GROUND BUSS BAR, TYP.
(E) MAIN GROUND CONNECTION POINT. (V.I.F.)
(E) GROUND LEAD. FIELD VERIFY & TIE INTO EXISTING BUILDING
GROUNDING SYSTEM
PROPOSED #2 STRANDED GREEN INSULATED GROUNDING WIRE, TYP.
(E) #2 STRANDED GREEN INSULATED COPPER GROUND LEAD, TYP. (V.I.F.)
CABINET GROUND WIRE STUDS, SEE DETAIL 1/E -3
PROPOSED INTERNAL GROUND BAR. (INSTALLED BY EQUIPMENT
MANUFACTURER)
PROPOSED FLEX CONDUIT STRAIGHT CONNECTOR FOR GROUNDING
CONNECTION TO INTERNAL GROUND BAR.
120,- 111
GROUNDING NOTES
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND
CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC
COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED
BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR
GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT
FROM TOWER OR POLE USING MFR'S PRACTICES.
3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE
COPPER THHN /THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE
ABOVE GROUND.
4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND
OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT &T WIRELESS, LLC.
REPRESENTATIVE.
5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION
AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS.
6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING
SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT &T
WIRELESS, LLC. REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING
SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING
7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES
INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS.
LEGEND
GROUNDING ROD NOTES
SYMBOL DESCRIPTION
GROUND INSPECTION WELL
COPPER GROUND ROD
COMPRESSION LUG
CADWELD CONNECTION
SIDE SPLICE CADWELD
FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM
SCHEMATIC GROUNDING PLAN
22x34 SCALE: 1/2" = 1' -0" 111x17 SCALE: 1/4" = 1' -0"
1
ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE
THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTILIZING
THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT
WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST
POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU.
2 POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS
ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE
PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE NC SYSTEM
GRIDS AND EXISTING COMMUNICATIONS FACILITY.
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
ECEIVED
MAY 23 2012
PERMIT CENTER
- PROJECT CONSULTANTS:
PLANS PREPARED BY:
WES TOWER
COMMUNICATIONS
_...E CORNERSTONE
ENGINEERING, INC.
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone- engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR:
_REV: :DATE - ISSUED FOR:
CONSTRUCTION
Y._
-DRAWN BY:
FCURRENT ISSUE DATE:
_ LICENSURE:
CHK. APV.
LJS
0
I JDG
I MWO
.2
CEI JOB NUMBER: 12 -13054
A
05 -21 -12
PERMIT
LJS
A
05 -04 -12
CLIENT REVIEW
LJS
-DRAWN BY:
FCURRENT ISSUE DATE:
_ LICENSURE:
CHK. APV.
LJS
0
I JDG
I MWO
05 -21 -12
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
SCHEMATIC GROUNDING PLAN
0
.2
CEI JOB NUMBER: 12 -13054
MASTER GROUND BAR
FACTORY INSTALLED IN THE
LOWER LEFT COMPARTMENT
INSULATED
I JDG
(
®p
0 0
0 0
0 0
0 0
0 0
f''' !
I
,
��
#2 GROUND LEAD CONNECTED
TO GROUND BAR WITH 2 -HOLE
COMPRESSION LUGS
ARGUS TE40 OR TE41 EQUIPMENT
CABINET ENCLOSURE
FACTORY INSTALLED EXTERNAL
GROUND WIRE STUDS TO
CONNECT GROUND LEAD AT
THE BASE OF ENCLOSURE (TYP
FRONT & BACK OF ENCLOSURE)
CONTRACTOR TO PROTECT
ALL EXPOSED SOLID BARE
TINNED COPPER GROUND
WIRE W/ 3/4 "0 FLEX CONDUIT
STRAIGHT CONNECTOR FOR
WATERTIGHT SEAL, TYP.
KNOCKOUT LOCATION TO
SUIT SITE CONDITIONS
GROUND BAR ATTACHMENT:
NOTE:
A
CONCRETE SUBSTRATE: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS WITH 2" MINIMUM EMBEDMENT.
WOOD FRAMED SUBSTRATE: (4) 3/8 "0 LAG SCREWS WITH 2" MINIMUM EMBEDMENT (ADD BLOCKING IF NECESSARY.
COAT ALL MECHANICAL
CONNECTIONS W/ "NO -LUX"
OR APPROVED EQUAL
WITHIN THE ENCLOSURE
GROUND LEAD CONNECTED
TO FACTORY INSTALLED
GROUND WIRE STUDS WITH
2 -HOLE COMPRESSION LUGS
(OPTIONAL @ FRONT OR
BACK BASE OF EQUIPMENT
e
05 -04 -12
SOLID CMU WALL: (4) 3/8 "0 HILTI TZ EXPANSION
HOLLOW CMU WALL: (4) 3/8 "0 HILTI HIT HY -20 WITH
CLEAR HEAT SHRINK ON
COMPRESSION LUGS
ANCHORS WITH 2" MINIMUM EMBEDMENT.
HIT -A STANDARD RODS. (3 3/8" EMBEDMENT)
COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION
DOUBLE LUGS, ATTACH TO GROUND BAR & INSTALL BY
ANTENNA CONTRACTOR (CADWELD TYPE -GL)
0
0
CABINET ENCLOSURE)
GROUND
GROUND
GREEN
op
�
LEADS ROUTED TO EITHER
BUSS BAR ( #2 STRANDED
COPPER) OR GROUND
\\,�
�
-,,
I
,
ii
%
_
_ o 0 0 0 0 o
\
° ° ° ° °
O o 0 0 0
0,1, 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0
i
O O O O O O O O O O O O o
0 0 0 0 0 0 0 0 0 0 0 0::
FA ll
0 0 0 0 0 0 0 0 0 0 0 0A
4 "x 24 "x 1/4" THK COPPER
/
1 1
O
PROVIDE ELECTRICAL
ISOLATORS @
GROUND BAR. INSTALLED
��
24"
�"
CONNECTION (TYP)
BY GENERAL CONTRACTOR
FIELD VERIFY
�
#2 SOLID BARE TINNED COPPER
WIRE CADWELD
RING ( #2 SOLID BARE TINNED COPPER)
(TYPE -GL)
ARGUS CABINET GROUNDING SCHEMATIC
11
GROUND BAR
9
22x34 SCALE: NTS 111x17
SCALE: NTS
22x34 SCALE: NTS 111x17
SCALE: NTS
HYLUG CONNECTOR INSTALLATION INSTRUCTIONS:
GROUND BAR ATTACHMENT:
(E) POWER SOURCE
CONTRACTOR TO MAKE ALL NECESSARY
ARRANGEMENTS AND PROVIDE ALL
REQUIRED LABOR AND MATERIALS TO
OBTAIN A 200 AMP, 120/240, 10 3W SERVICE
FROM EXISTING UTILITY PROVIDER.
1. SELECT PROPER HYLUG FOR THE WIRE SIZE USED.
2. STRIP CABLE OF INSULATION TO A LENGTH EQUAL TO THE BARREL OF THE
CONNECTOR.
3. INSERT CABLE FULLY INTO CONNECTOR.
4. APPLY THE PROPER NUMBER OF CRIMPS AS SHOWN BY NUMBER OF
COLORED BANDS.
5. CRIMP FROM TONGUE END OF CONNECTOR TOWARD CABLES FOR
TERMINALS AND CENTER SPLICE TOWARD CABLE FOR BUTT SPLICES
REQUIRING MORE THAN ONE CRIMP PER END.
HYLUG TYPE YGA CONNECTOR IS PREFILLED WITH PENETROX COMPOUND AND
STRIP SEALED.
BURNDY HYDRAULIC DIE SET #U1CRT- 1/U11T.
CONCRETE SUBSTRATE: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS
WITH 2" MINIMUM EMBEDMENT.
WOOD FRAMED SUBSTRATE: (4) 3/8 "0 LAG SCREWS WITH 2" MINIMUM
EMBEDMENT (ADD BLOCKING IF
NECESSARY.
SOLID CMU WALL: (4) 3/8 "0 HILTI TZ EXPANSION ANCHORS
WITH 2" MINIMUM EMBEDMENT.
HOLLOW CMU WALL: (4) 3/8 "0 HILTI HIT HY -20 WITH HIT -A
STANDARD RODS. (3 3/8" EMBEDMENT)
p IT, Ill RECEIVED
MAY 232012
PERMIT CENTER
#2 TW GREEN SERVICE
ENTRANCE GROUND IN
"0
(E) 200 AMP, 240V 10, 3W
METER SUBBASE
3/4 CONDUIT
TO (E) GROUND
0
SYSTEM
#2 TW GREEN SERVICE
ENTRANCE GROUND IN
"0
'
200A
(E) 200 AMP, 240V 10, 2 P SERVICE
ENTRANCE RATED FUSED DISCONNECT
W/ 2-200 AMP TYPE RUPTURING
CAPACITY (HRC) FUSES
3/4 CONDUIT
TO (E) GROUND
41/
200AF
GROUND CRIMPING GUIDELINES
8
GROUND
GROUND BAR ATTACHMENT
5
SYSTEM
22x34 SCALE: NTS
11x17 SCALE: NTS
22x34 SCALE: NTS
111x17 SCALE: NTS
T,
IIIIIIIIIIillllllll urllr
°1 °0 "' i�
IIIIIIIIIIIII IIIIIIIIillllllllllilllllllllllllllll
EQUIPMENT CHASSIS /
GROUNDING BUSS BAR /
(2) 3/8 "0 SS HEXNUT
( #2) TWO HOLE
COMPRESSION LUG
BAR
(E) 200 AMP, 240V 10, 3W
SERVICE PANEL W/ 200 AMP MAIN
�i.�
-��,��
\ 1111111! ��
r•
CABLE RACEWAY
NO -LUX
ANTI - OXIDIZING
COMPOUND
3/8 0 STAR
"
WASHER
PLAN
-
I��� GROUND WIRE STUD
- (TYP OF 2 @ FRONT
AND BACK OF CABINET)
�� �' ono
TYPE
=`
�
\1�
lHIII1
GR
i
.� Srout••
- .,
\��o
-�� —Trigs
` TYPE PT
�
"�N'- !�
�:• _
TYPE
I
GL
LUG
€ IUIIIIIII
_'
, 1
`
#2 TW GREEN SERVICE
ENTRANCE GROUND IN
"0
•
•
200, 2P
BREAKER AND DISCONNECT
1 PER RECTIFIER IN ARGUS
I
!�
i CLEAR HEAT SHRINK ON
COMPRESSION LUGS
I ; #2 STRANDED GREEN
INSULATED COPPER
GROUND LEAD TO BUSS
OR #2 SOLID BARE TINNED
COPPER TO GROUND RING
3/4 CONDUIT
200, 2P
,.,.� D"
+�
�.�■
TO (E) GROUND
POWER CABINET
SYSTEM
30, 2P
����
TYPE GT TYPE SS
i�
•
••
TYPE VS
HVAC IN ARGUS BATTERY
I
CABINET
NO T E .
20, 1P
GROUND LEADS ATTACHED TO EQUIPMENT CABINET AT
GROUND WIRE STUDS LOCATED AT THE FRONT AND BACK OF
CABINET BASE. FOR GROUNDING CONNECTIONS TO NOKIA GSM
CABINETS CHASSIS, GRIND OFF ALL ENAMEL COATINGS TO BARE
METAL AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG
CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE METAL.
NOTE:
CADWELD "TYPES" SHOWN ABOVE ARE EXAMPLES - CONSULT
WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS
TO BE USED FOR THIS PROJECT.
SEPARATE
PERMIT AND r
`
CADWELD DETAILS
4
ONE -LINE DIAGRAM
2
CABINET GROUNDING APPROVAL
REQUIRED
1
22x34 SCALE: NTS 111x17 SCALE: NTS
22x34 SCALE: NTS
111x17 SCALE: NTS
22x34 SCALE: 6" = 1' -0" 111x17 SCALE: 3" = 1' -0"
PROJECT CONSULTANTS:
PLANS PREPARED BY:
WESTOWER
COMMUNICATIONS
_�E CORNERSTONE
16928 WOODINVILLE - REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425,487.1732 FAX: 425.487.1734
EMAIL: cei @cornerstone - engr.com
WWW.CORNERSTONE- ENGR.COM
= PROJECT INFO:
WA094
TUKWILA
16500 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
KING COUNTY
- ISSUED FOR:
REV: =DATE:
CONSTRUCTION
ISSUED FOR:
-DRAWN BY: — -
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
0
I JDG
I MWO
CEI JOB NUMBER: 12 -13054
A
05 -21 -12
PERMIT
LJS
e
05 -04 -12
CLIENT REVIEW
LJS
-DRAWN BY: — -
CURRENT ISSUE DATE:
_ LICENSURE:
CHK.:
APV.:
LJS
0
I JDG
I MWO
05 -21 -12
= DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
•
DRAWING TITLE:
DRAWING NUMBER-
ELECTRICAL &
GROUNDING DETAILS
0
CEI JOB NUMBER: 12 -13054