Loading...
HomeMy WebLinkAboutPermit D12-182 - BEST BUY MOBILE - TENANT IMPROVEMENTBEST BUY MOBILE 17250 SOUTHCENTER PY SUITE 116 D12-182 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2009 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D12 -182 Occupant/Tenant: BEST BUY MOBILE Building Address: 17250 SOUTHCENTER PY, Suite No. 116 Parcel No.: 7888920020 Property Owner: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA 98006 Use: RETAIL Occupancy Group/Division: M Type of Construction: IIB Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 42 BUILDING OFFICIAL DATE THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES City oPfukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Project Name: BEST BUY MOBILE Permit Number: D12 -182 Issue Date: 07/30/2012 Permit Expires On: 01/26/2013 Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: RICHARD BURG Address: 117 HURT DR SE , SMYRNA GA 30082 Contractor: Name: HORIZON RETAIL CONST INC Address: 1516 S GREEN BAY RD , RACINE WI 53406 Contractor License No: HORIZRC072N5 Lender: Name: Address: Phone: 800 517 -6484 Phone: Expiration Date: 04/15/2013 DESCRIPTION OF WORK: INTERIOR REMODEL OF EXISTING SHELL BUILDING FOR THE SALES OF CELLULAR PHONES AND ACCESSORIES. INSTALLATION OF PARTITION WALLS, FLOORING, FINISHES, AND FIXTURES. Value of Construction: $100,000.00 Fees Collected: $2,433.96 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -182 Printed: 07 -30 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe rmance1 f work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this per Signature: Print Name: Date: 7-30—/0 This permit shall become n 1 and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC4/10 D12 -182 Printed: 07 -30 -2012 7: All construction shall be done in conform with the approved plans and the requireme f the International Building Code or International Residential Co International Mechanical Code, Washingtoingte Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ** *PLANNING DEPARTMENT CONDITIONS * ** 17: All storefront glazing shall remain transparent. 18: Signs are not approved as part of this permit. Any window signs, including posters proposed behind the window area, shall be in conformance with the Tukwila sign code. A separate sign permit is required. 19: ** *FIRE DEPARTMENT CONDITIONS * ** 20: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 21: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 22: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 23: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 24: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 25: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the doc: IBC -7/10 D12 -182 Printed: 07 -30 -2012 inspection tag is not completed, a reputable extinguisher service company will be req. to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 26: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 27: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 28: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 29: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2328) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 40: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -182 Printed: 07 -30 -2012 CITY OF TUKWILA Community Desrlopatent Depamuent Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 hltp: /hvv% ..ruk%cilaWA.gcw Building Permit No. Project No. 612-142, Date Application Accepted: OCt (120 14— Date Application Expires: 1. l 512 v . (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17250 Southcenter Parkway Tenant Name: Best Buy Mobile PROPERTY OWNER Name: Richard Burg Name: Wig Properties, LLC City: Smyrna State: GA Zip: 30082 Address: 4811 134th Place SE Email: richburg @uspermit.net City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Richard Burg Address: 117 Hurt Drive SE City: Smyrna State: GA Zip: 30082 Phone: (800) 517 -6484 Fax: (800) 517 -3758 Email: richburg @uspermit.net GENERAL CONTRACTOR INFORMATION Company Name: Out To Bid ",n Lo N �ji I l Address: /310 '� j 1� 9.v. t�j/yr City: "1 vo. State: Zip: (, ' Id Y1, 1 Phone: ` ow Phone: (612) 338 -6677 - Fax: (612) 338 -2995 Corm- Reg No.:10 s 1 A/ 91 t p qle: � t c I i.," Tukwila Business License No :: [1U1c�/fr1 I / 1 City: HAAppbconrolpomn- Appinlio .O., lino\201I ApplintiomTennit Appliemoa Retied- 84- I1.docx Revised: Augur 2011 el. i King Co Assessor's Tax No.: 788892 -0020 Suite Number: TBD Floor: 1 New Tenant: 0 Yes ❑.:No ARCHITECT OF RECORD. Company Name: C.M, Architecture Architect Name: Bruce M. Carlson Address: 219 'North Second Street, Suite. 301 City: Minneapolis stale: MN Zip: 55401 Phone: (612) 338 -6677 - Fax: (612) 338 -2995 Email: ajohnson @cmarch.com ENGINEER OF RECORD Company Name: Dunham Associates Engineer Name: Gregory Steinmetz Address: 50 South Sixth Street, Suite 1100 City: Minneapolis State: MN' Zip: 55402 Phone: (612) 465 -7550. Fax: (612) 465 -755.1 Email: todd.barnes @dunhameng.com LENDER/BOND ISSUED (required for projects SS,000 or greater per RCW 19.27. 5) Name: N/A / Address: City: State: Zip: Pogo I of 4 1 BUILDING PERMIT INFORM % ON - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 100,000 Describe the scope of work (please provide detailed information): Interior tenant remodel of an existing shell building for the sales of cellular phones and accessories. Installation of partition walls,. flooring, finishes, &.fixtures: Existing Building Valuation: $ Will there be new rack storage? [] Yes ❑.. No. If yes, a separate permit and plan submittal will: be :required.,. Provide All Building Areas in Square Footage Below gLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than I inches) *For an Accessory dwelling. provide the following: Lot Area (sit ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No ... If "yes ", explain: FIRE 1?ROTECTION/HAZARDOUS MATERIALS: Sprinklers` Qj Automatic Fire Alarm ❑ None ❑ Other_(specify), Will there be storage or use Of flammable, combustible orhazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials acrd storage locations on a separate 8 -1/2 " x 11 ".paper 'including qumrtities and Materlal'&fe ..Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County.,Health. Department, x:Applitmnu\Fam.•Appliamouion lmeVAtr ApphiatioarPcrrait Apptiarion Reviled - s- 9•ll.dod Revi.d: Augat2011 bh Paget of 4' Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 floor 1,682 1,682 0 0 II -B M' 2n1 Floor 3n° Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck gLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than I inches) *For an Accessory dwelling. provide the following: Lot Area (sit ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No ... If "yes ", explain: FIRE 1?ROTECTION/HAZARDOUS MATERIALS: Sprinklers` Qj Automatic Fire Alarm ❑ None ❑ Other_(specify), Will there be storage or use Of flammable, combustible orhazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials acrd storage locations on a separate 8 -1/2 " x 11 ".paper 'including qumrtities and Materlal'&fe ..Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County.,Health. Department, x:Applitmnu\Fam.•Appliamouion lmeVAtr ApphiatioarPcrrait Apptiarion Reviled - s- 9•ll.dod Revi.d: Augat2011 bh Paget of 4' PERMIT APPLICATION NOTES — Value of Construction —.In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review: — Applications for which no permit is issued within 1S0 days following the date of application shall expire by limitation.. The Building Official grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated: Section 1053.2 International Building Code (current edition). I HEREBY CERTIFY THAT I VE.READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BETRUE UNDER PENALTY OF PERJURY BY iF LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 A HORI A 6;2p /Z Print Name: l'Cl4111b, A -/l U LC5 Day Telephone: ,?0 /7 - Signature: Date: Mailing Address: It 7 -,dIAi Z TI vlpplicmonnWcennpApplintiem On Line 2011 Applications \P t Apptiaenn Revised - B-9- 11.doca. Raved' Aegnu 2011 bh 8 z Sta1t•; .. Zip Page 4of4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http://www.TukwilaWA.ov RECEIPT Parcel No.: 7888920020 Permit Number: D12 -182 Address: 17250 SOUTHCENTER.PY TUKW Status: APPROVED Suite No: Applied Date: 05/30/2012 Applicant: BEST BUY MOBILE Issue Date: Receipt No.: R12 -02223 Initials: User ID: JEM 1165 Payment Amount: $1,476.90 Payment Date: 07/30/2012 08:59 AM Balance: $0.00 Payee: HORIZON RETAIL CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 242742 1,476.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $1,476.90 1,472.40 4.50 doc: Receiot -06 Printed: 07 -30 -2012 Ci, of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -01728 Initials: JEM Payment Date: 05/30/2012 User ID: 1165 Total Payment: 1,115.75 Payee: C.M. ARCHITECTURES, P.A. SET ID: S000001751 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D12 -182 EL12 -0498 M12 -081 TOTAL: Amount 957.06 104.83 53.86 957.06 TRANSACTION LIST: Type Method Description Amount Payment Check 120598 1,115.75 TOTAL: 1,115.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 104.83 1,010.92 1,115.75 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 II2., (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 1�t2 -I3?, Project: � p.b-; V5u( -1,Ma& Type of Inspection: 'FINAAu Address: 5" V1 — (V 00 s ?Lk Date Called: Special Instructions: Date Wanted:. Q(_Ca -12 (.m. rm. Requester: Phone No: 9'2 - -C1'3S —I 825 ©.Approved per applicable codes. El Corrections required prior to approval. COMMENTS: vv\ L piL4 ( ei.lPNrc. ,'— f)P' In'spect9 Date: EINSPECTION FEE REQUJRED. Prior to next inspection. fee must be patrd at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Vag_ (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Projects . / /)') •/ / :') J % 3 7( t/ / J Q b) ( Type of Inspection: ' . .? / 7 .2#1,/a.‘1-:-• (,7, . '— 1 Address: G s:: 7 � J . -r / 0 JO (',(l Date Called: '' / Special Instructions: Date Wa ted:. 3- Z3- )Z- lm: m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6). Date: .23/Z n R IN 'PECTION FEE REQUIREb. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project: _ f$f 7" '/ IY�O,�2.L f Type of Inspection: S2 /S,4A/'— 'L) /c / L ] Al 6.. Address: ' 72 5 0 So (".vi y'Cc L/ Date Called: Special Instructions: Date Wanted:.:in1 x-2o —rz ' Requester: - Phone No: ElApproved per applicable codes. Corrections required prior to approval... COMMENTS: ,_..- -71A 17f7a1/ /t y9- / — Pe214 -1.4 Inspeci F: REINSPECTION FEE REdUIRED. Prior to next inspection fee must be =' aid at 6300 Southcenter Blvd., Suite 100. Call to schedule. reinspection INSPECTION, NO. INSPECTION RECORD . Retain a copy with permit-2( 6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' - 6300 Southcenter Blvd., #100, Tukwila. WA 98188 4, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: -----A- i .i _ 13-es I Lsc,17/ AA,4 b‘ir Type of_Inspecir - .., Address: I ri 2...50 ._. 0.4111--Cj44.1 Date Called: Special Instructions: i / Date Wanted: o ,_. ..„ :: -,,,—. Requester: Phone Phone"o:2---cn'''—, 0 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: t4iLtil DAY_ . • . , • InspectorL._ X I t Date: ' CJD, INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 'DkZ --Ic62 t ?Z PERMIT NUMBERS DEITY OF TUKWILA FIRE DEPARTMENT 444 Andover ParktEast, Tukwila, Wa. 98188 206- 575 -4407 Pro ect: 1 Sprinklers: kt19-5 Type of Inspection: Fire Alarm: v\a, - L __ Address: \-7 z50 Suite #: S , c , if I 1 (o Contayc Person: �-- R� C-A`\\ Pre -Fire: Special Instructions: Permits:. Phone No.: 2 Ga 93 1 --,\'6 Pr) ■pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: ''e5 Sprinklers: kt19-5 Date: Fire Alarm: v\a, - L __ Hood & Duct: I Monitor: Pre -Fire: Permits:. Occupancy Type: Pr) Inspector: ,__)N\ " 5) Date: \\ `z Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di a - /g- r -f /701- / -- s - /73 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Proect: (-5e' s� Q � V J^^v b, Typ of Insp coon: v �'�. s � suite � 7 50 Suite #: � .5 , C _ P'� / Contact P rson: Special Instructions: • Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /, ¶ , d--- Date: E f (9-g // Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection.. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /2 - /Fz /2- S -/73 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: 0c .57i. /3 C4 1 »1vb ■ ; / Type of Inspection: 5, l . ' 4 1 C'l e. N-- ` f c.,,...- 4-4_ Address: / % z .5-4,* Suite #: 5 C Ple l....Y. Contact Person: S.4,- 9kl ,Vo.4,-, Special Instructions: Permits: ,..-- Phone No.: 2,s'3 - FZ6- /,ems Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: m 53 - Sprinkrers:--- -°",..- ---- ..,Rood- &Duct .�-- --""'^ Pre =Fire: Fire Alarm:/ Hrs.: Monitor: _ �. -� - ---- Permits: ,..-- ----- Occupancy Type: Inspector: m 53 Date: & pJ"�jZ Hrs.: / $100.00 REINSFECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance - Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 2009 Washington State,Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Info Project Address Best Buy Mobile Date 5/23/2012 South Center Square For Building Department Use I Tukwila, WA Applicant Name: Shawn Whalen Applicant Address: 50 South 6th Street Ste 1100, Minneapolis, MN 55402 Applicant Phone: 612 - 465 -7550 FILE COPY Permit No., REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECENEQ CITY OF TUKVVILA MAY 3 0 2012 PERMIT CENTER 2009 Washington State Energy Code Compliance'Forin for Nonresidential and Multifamily Residential interior Lighting Summaiy "T LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Project Info Project Address Best Buy mobile Date 5/23/2012 South Center Square For Building Department Use Tukwila, WA Applicant Name: Shawn Whalen Applicant Address: 50 South 6th Street Ste 1100, Minneapolis, MN 55402 Applicant Phone: 612 - 465 -7550 Project Description TOILET ROOM ❑ Plans Included requirements. ❑ New Building ❑ Addition ✓ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 " Gross Intenor Area in fie Allowed x Area SALES RETAIL 1.33 1170 1556 TOILET ROOM RESTROCM 0.80 45 36 STOCK /OFFICE OFFICE 0.91 208 189 SALES DISPLAY ALLOWANCE PER TABLE 15 -1, NOTE 10 0.60 608 365 ALLOWANCE PER NOTE 10 1.00 1000 1000 SALES D /D1 - 2' SHOW WINDOW LED TRACK LIGHTING 1 100 100 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3146 Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES B /BE - 2'X2' RECESSED 2 -LAMP FLUORESCENT 6 61 366 SALES P - PENDANT 6 16 96 SALES D /D1 - LED TRACK LIGHTING W /5A CURRENT LIMITER 1 600 600 SALES Ex.- EXISTING 2'x4' 3 -LAMP FLUORESCENT 14 85 1190 OFFICE Ex.- EXISTING /RELOCATED 2'x4' 3 -LAMP FLUORESCENT 3 85 255 SALES D /D1 - 2' SHOW WINDOW LED TRACK LIGHTING 1 100 100 RESTROOM EXISTING (2)LAMP 4' FLUORESCENT 1 61 61 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2668 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Irtiterior Lighting Summary (back) " " LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 OT 2 two (amps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. - TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA2 (W /ftZ)U se' LPA` (Wife) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel/motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies3 (except mall concourses) 1.10 Museum . 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. - The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. OPERINIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -182 PROJECT NAME: BEST BUY MOBILE SITE ADDRESS: 17250 SOUTHCENTER PY DATE: 05/30/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Aiti A-uJ) (9—(0)---(- OIL pew ( o U - D1 e uilding Division ® Fire Prevention 17--C 1■4`. t'a" Pubic Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 05/31/12 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ri No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/28/12 Approved ❑ Approved with Conditions N Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 Contractors or Tradespeople Fer Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HORIZON RETAIL CONST INC UBI No. 601483044 Phone 2626386000 Status Active Address 1500 Horizon Drive License No. HORIZRC072N5 Suite /Apt. License Type Construction Contractor City Sturtevant Effective Date 8/25/1993 State WI Expiration Date 4/15/2013 Zip 53177 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date HENDERSEN, JON E Cancel Date 01/01/1980 Amount GUSTIN, ROBERT L 7 01/01/1980 5919211 HENDERSON, JON E 03/29/2013 01/01/1980 JAWORT, DAN Agent 01/01/1980 ZURICH AMERICAN INS CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 HANOVER INS CO 1592447 04/10/2002 Until Cancelled $12,000.00 04/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 ZURICH AMERICAN INS CO 5919211 03/29/2009 03/29/2013 $1,000,000.00 04/06/2012 6 ZURICH AMERICAN INS CO 59192110001 03/29/2006 03/29/2009 $1,000,000.00 03/24/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 07/30/2012 Best Buy Mobile Contacts BEST BUY MOBILE 7601 PENN AVENUE SOUTH RICHFIELD, MN 55423 ARCHITECTURAL PROJECT MANAGER RHONDA DEHLER Office: (612) 291 -8930 Mobile: (651) 356 -9884 Email: rhonda.dehler©bestbuy.com CONSTRUCTION PROJECT MANAGER: ALLEN MCKENZIE Office: (612) 291 -3323 Mobile: (612) 253 -5838 Email: allen.mckenzie@bestbuy.corn STORE PLANNER: DANIELLE KOSTER Phone: (612) 291 -8925 Email: danielle.koster©bestbuy.corn Architect BRUCE M. CARLSON, ARCHITECT 219 NORTH SECOND STREET SUITE 301 MINNEAPOLIS, MN 55401 -1454 Phone: (612) 338 -6677 Fax: (612) 338 -2995 ARCHITECT PROJECT #: 12114.033 Contact: ANGIE FEULNER Phone: (612) 547 -1352 Email: afeulner©cmarch.com BRUCE M. CARLSON architecture planning interior design Mechanical / Electrical DUNHAM ASSOCIATES 50 SOUTH SIXTH STREET SUITE 1100 MINNEAPOLIS, MINNESOTA PHONE: (612) 465 -7550 FAX: (612) 465 -7551 Electrical Contact: TROY ROLPH Direct: (612) 465 -7638 Email: troy.rolph©dunhameng.com Mechanical Contact: TODD BARNES Direct: (612) 465 -7685 Email: todd.barnes©dunhameng.com 55402 DUNHAM I Project Directory PROJECT LOCATION: SOUTHCENTER SQUARE SPACE: #TBD 17250 SOUTHCENTER PARKWAY TUKWILA, WA 98188 Contacts: CLAUDINE SIEDLER Phone: (425) 641 -2044 Email: csiedler©wigproperties.corn LANDLORD: WIG PROPERTIES, LLC 4811 134TH PLACE SE BELLEVUE, WA 98006 Contacts: CLAUDINE SIEDLER Phone: (425) 641 -2044 Email: csiedler©wigproperties.corn BUILDING DEPARTMENT: CITY OF TUKWILA COMMUNITY DEVELOPMENT DEPT PERMIT CENTER 6300 SOUTHCENTER BLVD SUITE 100 TUKWILA, WA 98188 Contacts: BOB BENEDICTO Phone: (206) 431 -3670 Email: bob.benedicto©tukwilawa.gov Signage EVERBRITE, LLC 4949 SOUTH 110TH STREET GREENFIELD, WI 53228 (414) 529 -3500 www.everbrite.com Contacts: CHAD ROGOWSKI Direct: (414) 529 -7218 Email: crogowski©everbrite.com 0 e 0 0 • e j „,. .00 � i ge. e G e ® • e • . Site Plan (1) 52” TICKET (STACKED) INTERNALLY ILLUMINATED SIGN (1) 15" TICKET, INTERNALLY ILLUMINATED Vicinity Map :`aim >a L 0 J Q.' U w 0 W z Z Li W I- EC 0 0 0 Li z n. 05 -22 -12 DATE ISSUED OS 0 z w zo0No ,c1.- ED U • I t —I— c U � L 5 M'4) 0 z�N F z "�� ) ~ O W ul I^... V 7 tn° - W NIL IZW J F- Z Z Q z��ZOX� N�O-� w CO I SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUMBER: # 0 0 W < woo co Qr U 0 Q z p (n Q U W =WQJ I—uD� D Q U N PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: NO SCALE COVER SHEET Cs- Sheet Index CS -1 COVER SHEET CS -2 SYMBOLS / ABBREVIATIONS Architectural A -1 DEMOLITION AND FLOOR PLANS A -2 SCHEDULES, LEGENDS & DETAILS A -3 FLOOR FINISH PLAN A -4 REFLECTED CEILING PLAN A -7 INTERIOR ELEVATIONS A -10 STOREFRONT ELEVATION & PLAN A -11 SPECIFICATIONS A -12 SPECIFICATIONS Fixture Plans F -1 FIXTURE PLAN Mechanical M -1 HVAC PLAN M -2 PLUMBING PLAN M -3 MECHANICAL SPECIFICATIONS Electrical E -1 POWER PLAN, SCHEDULES, RISER & E -2 LIGHTING PLAN & SCHEDULES E -3 ELECTRICAL SPECIFICATIONS & DETAILS CALCS PLANNING APPROVED No changes can be made. plans without approval Planning Division • to th =. from the of DCD . Approval Date:, l 0 - LA if SEPARATE PERMMIT REQUiRED FOR: oe: han:cal -lectrical tumbing as Piping Ly of Tukwila 'r7`'NG DIVISION OF TUKWILA. •W( 3 0 2012 CENTEF cb qi... x I Pl n t.:::::Aoval ti--i.: ; o :.pproved REVISIONS R'© changes shall be made to of •.'mris without prior approval _ -' U .v :ia Building Division. - ,Y:stono will require a new L,:i m =y it :Jude additional plan EL COPY Permit Nor, review approval is subject to errors of construction documents oiwtion of any adopted code or net ". I "ions ins By the scope of plan submittal review fees. lez and omissions. does not authorize ordinance. Receipt is acknowledged: Date: , : -.X.I9%. City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 "5- . We-, City of Tukwila BUILDING DIVISION p 1/2:00. S CITY PERMIT 1 A A Revisions 0 J Q.' U w 0 W z Z Li W I- EC 0 0 0 Li z n. 05 -22 -12 DATE ISSUED OS 0 z w zo0No ,c1.- ED U • I t —I— c U � L 5 M'4) 0 z�N F z "�� ) ~ O W ul I^... V 7 tn° - W NIL IZW J F- Z Z Q z��ZOX� N�O-� w CO I SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUMBER: # 0 0 W < woo co Qr U 0 Q z p (n Q U W =WQJ I—uD� D Q U N PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: NO SCALE COVER SHEET Cs- Abbreviations A AB ACC ACOUS ACT AD ADD ADJ ADMIN AFF AGG AHJ AHU B BC BD BITUM BL BLDG BLKG BLVD BM B.O. BOT BP BRG BSMT BTWN BUR BW C C CAB CAP CARP CB CD CEM CEM PL CER CG CH CHRL CIP CJ CL CLG CLKG CLO CLR CLSR CMU CO COL COMP CONC COND CONN CONST CONT COORD CORR CR CT CTR CTSK CU CW D d db D DBL DECID DEPT DET DF DIA DIAG DICA DIFF DIM DISP DL DN DR DS DSP DW DWG DWR E E EA EH EJ EL ELEC ELEV EMERG ENAM ENTR EP EQ EQJ EQUIP ETR EWC EXC EXG EXH EXP EXT Anchor Bolt According /Accordion Acoustical Acoustical Ceiling Tile Area Drain Addendum Adjustable /Adjacent Administration Above Finished Floor Aggregate Authority Having Jurisdiction Air- Handing Unit ALUM Aluminum ALT Alternate /Alteration ANOD Anodized AP Access Panel /Apron Panel APPROX Approximate APT Apartment ARCH Architect /Architectural ASPH Asphalt AVE Avenue AVG Average AWP Acoustic Wall Panel Bottom of Curb Board Bituminous Building Line Building Blocking Boulevard Beam/Bench Mark Bottom of Bottom Building Paper Bearing Basement Between Built -Up Roof Bottom of Wall Celsius /Centigrade Cabinet Capacity Carpet Catch Basin /Chalkboard Ceiling Diffuser Cement Cement Plaster Ceramic Corner Guard Coat Hook Chair Rail Cast iron Cast In Place Control Joint Center Line Ceiling Caulking Closet Closet Clear Closer Concrete Masonry Units Clean Out Column Composite /Composition Concrete Condition Connect /Connection Construction Continuous Coordinate Corridor Cold Roiled Ceramic Tile /Curtain Track Center Countersunk Cubic Cold Water Penny (nails) Decibel Clothes Dryer Double Deciduous Department Detail Drinking Fountain Diameter Diagonal Drilled in Concrete Anchor Diffuser Dimension Disposal Dead Load Down Door/Drain Down spout Dry Stand Pipe Dishwasher Drawing Drawer East Each Expansion Bolt Expansion Joint Elevation Electrical Elevator Emergency Enamel Entrance Electrical Panelboard Equal/Earthquake Earthquake Joint Equipment Existing To Remain Electric Water Cooler Excavate/Excavation Existing Exhaust Expansion Exterior F F FA FAB FB FBD FBO FD FDC FDN FE FEC FF FG FH FHC AIMS FHWS FlC FIN FlO MT FL FLASH FLOUR FM FOB FOC FOF FOIC F010 FOIV FOM FOS FP FR FRL FRP FRT FS FT FTG FTIC FURN FURR FLIT FWP G G GA GALV GB GC GD GFRC GFRG GFRP GL GGLAMYP GYP BD H H HB HC HCW HDBD HDNR HDR HDWD HDWE HM HORIZ HP HR HT HTG HW• HWR D E G ND NSP NST NSUL NT J JAN JST JT K KIT KO KP L L LAB LAM LAV LH LHR LKR LL LP LP. LSG LT LTWT Fahrenheit Fire Alarm/Forced Air Fabricate Flat Bar Fiber Board Furnished By Owner Floor Drain Fire Department Connection Foundation Fire Extinguisher Fire Extinguisher Cab Factory Finish Float Glass Flathead Fire Hose Cabinet Flathead Machine Screw Flathead Wood Screw Furnished and Installed by Contractor Finish Furnished and Installed by Owner Furnished and Installed by Tenant Floor Flashing Fluorescent From/Factory Mutual Research Corporation Face Of Brick Face of Concrete Face of Finish Furnished by Owner Installed by Contractor Furnished by Owner Installed by Owner Furnished by Owner Installed by Vendor Face of Masonry Face of Studs Fireproofing) Freezer/Fire Retardant Fiber Reinforced Laminate Fiber Reinforced Plastic Fire Retardant Treated Full- Size/Floor Sink Foot or Feet Footing Furnished by Tenant installed by Contractor Furnace /Furnish Furring Future Flat Wall Paint Gas Gauge Galvanized Grab Bar General Contractor Garbage Disposal Glass Fiber Reinforced Glass Fiber Reinforced Glass Fiber Reinforced Glass /Glazing /Glazed Glue- Laminated Wood Gypsum Gypsum Wallboard Concrete Gypsum Plaster Hinge/High Hose Bid Handicap/Hollow Core Hot and Cold Water/Hollow -Core Wood Hardboard Hardener Header Hardwood Hardware Hollow Metal Horizontal Horsepower/High Point/Heat Pump Hour/Handrail Height Heating Hot Water Hot Water Return nside Diameter/Inside Dimension nvert Elevation nsulating Glass ndicated nspection nstallation nsulation nterior Janitor Joist Joint Kitchen Knock Out Kick Plate Left/Length Laboratory Laminated Lavatory Left Hand Left-hand Reverse Locker Live Load Low Point Loss Prevention Laminated Safety Glass Light Lightweight M M/S MACH MAINT MAS MAT MAX MCW MDF MDO MECH MEMB MT MTL MEZZ MFR MG MH MIR MO MOD MS MTD MUL N N N% NOM NTS 0 0/ OA OC OD OFD OPNG OPP OSB P PB PBB PBD PC PCD PERF PERP PG PH PL PLF PLAS PLYW PNL PNT POL PP PR PRE FAB PT PTD PTDW PTN PVMT Q QT QTR R Mirror with Shelf Machine Maintenance/Maintain Masonry Material Maximum Mineral Core Wood Medium - Density Fiberboard Medium - Density Overlay Mechanical Membrane Entry Mat Carpet Tile Metal Mezzanine Manufacturer/Manufacturing Mirror Glass Manhole Mirror Masonry Opening Module/Modify Machine Screw Mounted Mullion North Number Nominal Not -to -Scale Over Overall On- Center Outside Diameter Overflow Drain Opening Opposite Oriented Strand Board Paint/Power Pegboard Plaster Baseboard Particleboard Precast Paper Cup Dispenser Perforated Perpendicular Plate Glass Phase Plastic Laminate Plastic Flooring Plaster Plywood Panel Paint Polish Push Plate Pair Prefabricate Preservative Treated/Point/ Post - Tensioned Paper Towel Dispenser Paper Towel Dispenser & Waste Receptacle Partition Pavement Quarry Tile Quarter R Riser R &S Backer Rod and Sealant RAD Radius RB Rubber -Base RCP Reflected Ceiling Plan RD Roof Drain RECEP Reception RECEPT Receptacle RECT Rectangular REF Reference/Refrigerator REINF Reinforced REQ Required RES Resilient RET Retaining/Retum REV Revision RH Robe Hook/Round Head/ Right -Hand RM Room RO Rough Opening ROW Right Of Way RP Radius Point RRL Rub Rail RT Rubber The RWL Rainwater Leader RVS Reverse S S_ SAN SC SCD SCHED SCW SD SEC SECT SF SFC SGEN SHR SHT SHTG SHV SLR SMR SMS SND SNW SQ SS SST ST STC STD STL STOR SUBFL SURF SUSP SYM T T T &B T &G TB TCC TD TDW TEL TEMP TER TF TG THK THR T.O. TOD TOIL TOL TOP TOS TOW TPD TYP U UBC UC UNFIN UNO UR UTIL V VAR VCT VERT VIF VOL VP VT VWC W W W/O W/ WAIN WC WD WOW WF WG WP WH WR WT South /Shelf Shelf and Rod Sanitary Solid Core Seat Cover Dispenser Schedule Solid Core Wood Soap Dish /Soap Dispenser Second Section Square Feet Special Floor Coating Semigloss Enamel Shower Sheet Sheathing Sheet Vinyl Sealer Sheet -Metal Raceway Sheet -Metal Screws Sanitary Napkin Dispenser Sanitary Napkin Waste Receptacle Square Service Sink Stainless Steel Stone Sound- Transmission Class Standard Steel Storage Subfloor Surface Suspended Symmetrical Top/Threshold /Tread/Toilet Top & Bottom Tongue & Groove Towel Bar/Tack Board Top of Curb/Top of Concrete Towel Dispenser Towel Dispenser & Waste Telephone Tempered/Temporary / Temperature Terrazzo Top of Footing Tempered Glass Thick Threshold Top of Top of Deck Toilet Tolerance Top of Pavement Top of Steel Top of Wall Toilet Paper Dispenser Typical Uniform Building Code Under Counter/Undercut Unfinished Unless Noted Otherwise Urinal Utility Variable/Varnish/Varies Vinyl - Composition Tile Vertical Verify In Field Volume Veneer Plaster Vinyl Tile Vinyl Wall Covering West/Water /Clothes Washer/WATT Without With Wainscot Water Closet Wood Window Wide Flange Wire Glass/Wire Gauge Water Heater Work Point/Waterproof Waste Receptacle Weight Symbols REVISION REFERENCE ENLARGED PLAN ROOM IDENTIFICATION SYMBOL DOOR /SHUTTER SYMBOL WALL TYPE DIMENSION NOT TO SCALE COLUMN OR GRID UNE /-REVISION NUMBER SALES 101 1140 S 1' (NTS) ENLARGED PLAN REFERENCE SHEET NUMBER ROOM NAME ROOM NUMBER ROOM SQUARE FOOTAGE DOOR NUMBER REFERENCE NUMBER GRID LINE LINE BETWEEN GRID OR COLUMN UNES GRID LINE DETAIL REFERENCE WALL SECTION REFERENCE INTERIOR ELEVATION REFERENCE EXTERIOR ELEVATION REFERENCE NORTH ARROW FINISH TAG DETAIL REFERENCE NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER PROJECT NORTH C -1 General Notes 1. THESE DRAWINGS ARE THE PROPERTY OF BEST BUY CORP. NO CHANGES TO THESE DOCUMENTS, EITHER IN WHOLE OR IN PART, MAY BE MADE WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE INDIVIDUAL WHOSE NAME AND SIGNATURE APPEARS UPON THE DOCUMENTS. 2. WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODE REQUIREMENTS AND ALL STATE AND FEDERALLY MANDATED REQUIREMENTS IN EFFECT AT THE TIME OF SUBMITTAL FOR BUILDING PERMITS. 3. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION SAFETY PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SAFETY AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH STATE AND /OR FEDERAL CONSTRUCTION SAFETY GUIDEUNES. 4. IF APPUCABLE, THE OWNER SHALL PAY ALL APPUCABLE ENVIRONMENTAL UTIUTIES FEES AT BUILDING PERMIT ISSUANCE. 5. GENERAL CONTRACTOR TO THOROUGHLY REVIEW THESE PLANS, VISIT THE SITE, VERIFY DIMENSIONS BEFORE SUBMITTING A BID, AND NOTIFY THE ARCHITECT OF DISCREPANCIES. 6. ITEMS SHOWN AS N.I.C. ON PLANS MAY REQUIRE SEPARATE SUBMITTALS, APPROVALS AND PERMITS. INSTALLING CONTRACTOR(S) ARE RESPONSIBLE FOR OBTAINING EACH REQUIRED PERMIT. 7. TENANT SIGNAGE SHOWN IS NOT A PART OF THIS WORK (N.I.C.). GENERAL CONTRACTOR IS RESPONSIBLE TO BRING POWER TO SIGNAGE AS REQUIRED. 8. FOLLOWING ITEMS INCLUDED TO THE DEFERRED SUBMITTAL, GC RESPONSIBLE FOR SECURING PERMITS FOR ITEMS B, C AND D BELOW: A. B. C. D. EXTERIOR /INTERIOR SIGN, SPRINKLER SYSTEM, SECURITY AND FIRE ALARM SYSTEMS, LOW VOLTAGE AS REQUIRED. GC TO COORDINATE LOW VOLTAGE REQUIREMENTS WITH BBM LOW VOLTAGE TEAM TO SECURE COMPLETE LOW VOLTAGE PERMIT FOR GC SCOPE AND BBM FURNISHED AND INSTALLED ITEMS. 9. MAINTAIN EXISTING FIRE LANES, WHERE APPUCABLE. 10. VERIFY IN FIELD, ELEVATIONS, FLOW LINES, EXISTING CONDITIONS, AND POINTS OF CONNECTION WITH SITE IMPROVEMENTS PRIOR TO THE START OF CONSTRUCTION. ALERT ARCHITECT AND ENGINEER OF DISCREPANCIES BEFORE PROCEEDING WITH WORK. 11. REPAIR EXISTING PUBLIC FACILITIES DAMAGED DURING THE COURSE OF CONSTRUCTION TO THE SATISFACTION OF THE CITY OF TUKWILA. 12. BUILDING HEIGHTS AND ELEVATIONS SHALL BE MEASURED FROM FINISH FLOOR UNLESS OTHERWISE NOTED. 13. ENSURE FINISH MATERIALS WILL BE FLUSH WITH ADJACENT SURFACES AND JOINTS, (EXCEPT WHERE INDICATED OTHERWISE). 14. GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS AND PAYING APPUCABLE FEES PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. THESE FEES SHALL INCLUDE, BUT NOT BE LIMITED TO, THOSE FEES REQUIRED BY CITY ORDINANCES SUCH AS TRAFFIC IMPACT FEES, NOISE FEES, PUBLIC FACILITIES FEES, FIRE IMPACT FEES, AND REGIONAL TRANSPORTATION IMPACT FEES. 15. DURING CONSTRUCTION, ACCESS SHALL BE PROVIDED TO AREAS OF THE SITE COMPLETELY AROUND STRUCTURES. 16. ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC. LOCATED IN RATED PARTITIONS SHALL BE BACKED WITH DRYWALL AS REQUIRED TO MAINTAIN RATING. CONTRACTOR TO VERIFY WALL THICKNESS REQUIRED FOR ALL ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC. 17. PROVIDE DOUBLE STUDS, BLOCKING, BRACING AND BACK -UP PLATES WHERE REQUIRED TO SUPPORT EQUIPMENT, MISCELLANEOUS ITEMS, I.E., TYPICAL CASEWORK, CABINETS, GRAB BARS, TOILET ACCESSORIES, FIXTURES, SIGNS, HAND RAILING, ETC. 18. COLUMN UNES SHOWN ON FLOOR PLANS WILL HAVE COLUMN LINE INDICATOR BUBBLES SHOWN ON THEM. THESE BUBBLES ARE FOR REFERENCE ONLY. 19. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE OWNER'S REPRESENTATIVE BEFORE CONTINUING WITH CONSTRUCTION. 20. CONTRACTOR SHALL VERIFY DIMENSIONS AND COORDINATE TRADES. CONTRACTOR TO VERIFY WITHIN FIRST 3 DAYS. 21. CONTRACTOR SHALL VERIFY EQUIPMENT LOCATIONS AND DIMENSIONS AND REQUIRED CLEARANCES OF EQUIPMENT (REFER TO DRAWINGS, SPECIFICATIONS, AND EQUIPMENT MANUALS & CUT SHEETS). DRAWINGS REFLECT EXISTING CONDITIONS INCLUDING: COLUMN LOCATIONS AND SIZES, EXIT DOOR LOCATIONS AND SIZES, AND ROOF TOP MECHANICAL UNIT LOCATIONS. 22. SYMBOLS, ABBREVIATIONS, AND NOTES MARKED "TYPICAL" OR "TYP" SHALL APPLY IN ALL SIMILAR CIRCUMSTANCES, UNLESS OTHERWISE NOTED. 23. PROVIDE CLEANUP AND REMOVAL OF DEBRIS FROM PREMISES CAUSED BY THIS WORK. 24. BEFORE SUBMITTING BID PROPOSALS FOR THE WORK IN THESE SPECIFICATIONS & DRAWINGS, EACH CONTRACTOR AND SUBCONTRACTOR SHALL EXAMINE THE SITE AND FAMIUARIZE THEMSELVES W/ EXG. CONDITIONS BEFORE PROCEEDING. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED OR LACK OF KNOWLEDGE OF EXISTING CONDITIONS. IN CASE OF ANY INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS, THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. NOT REPORTING ANY SUCH UNSUITABLE CONDITION WILL CONSTITUTE ACCEPTANCE OF ALL CONDITIONS BY CONTRACTOR AND /OR SUBCONTRACTOR. 25. NO HAZARDOUS MATERIALS, LIQUIDS OR CHEMICALS SHALL BE STORED OR USED WITHIN THE SUBJECT BUILDING AS TO REQUIRE A HAZARDOUS CLASSIFICATION PER APPUCABLE CODE. 26. SWITCHES AND CONTROLS FOR UGHTS, VENTILATION, FIRE ALARMS, ETC. MUST BE PLACED NO MORE THAN 48" AFF. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALUNG LIGHT FIXTURE SUPPORTS AS REQUIRED. Bidding Note 1. FOR QUESTIONS REGARDING SITE ACCESS, STOREFRONT, ARCHITECTURAL CRITERIA, ENGINEERING DESIGN, DELIVERY DATES, CONSTRUCTION RULES AND REGULATIONS, THE SCOPE OF LANDLORD'S AND TENANT'S WORK AND STORE OPENING REQUIREMENTS, PLEASE CONTACT THE TENANT COORDINATOR OR MALL. ALL SITE VISITS DURING THE BIDDING PROCESS MUST BE COORDINATED THROUGH THE MALL. GC'S TO USE THE UTMOST DISCRETION TO THE CURRENT TENANTS WITH NO INFORMATION ON WHO IS MOVING IN. IF QUESTIONS ARE ASKED, PLEASE REPLY THAT THE WORK IS FOR THE LL. IF GC DOES NOT COMPLY, THEY MAY BE DISQUAUFiED FROM BIDDING. Fire Department Notes 1. THE SPRINKLER CONTRACTOR SHALL CONFIRM FLOW TEST INFORMATION WITH THE LOCAL FIRE DEPARTMENT OR WATER DEPARTMENT. 2. GENERAL CONTRACTOR SHALL PROVIDE REVISED FIRE ALARM SYSTEM DRAWINGS FOR APPROVAL AND SEPARATE PERMIT. SECURE FIRE DEPARTMENT PERMITS AND ACCEPTANCE OF INSTALLED LIFE SAFETY SYSTEM(S), FIRE PROTECTION, AND FIRE ALARM PRIOR TO BEST BUY MOBILE OCCUPYING THE SPACE. 3. A MINIMUM OF ONE 2A1OBC CLASSIFICATION FIRE EXTINGUISHER SHALL BE PROVIDED FOR EVERY 3000 S.F. AND PLACED NOT TO EXCEED 75' TRAVEL DISTANCE. MOUNTING REQUIREMENTS AND LOCATIONS SHALL BE COORDINATED AND ARE SUBJECT TO FIRE DEPARTMENT APPROVAL. Applicable Codes ZONING MUNICIPALITY BUILDING ADDRESS OCCUPANCY CLASSIFICATION CODES BUILDING CODE MECHANICAL CODE PLUMBING CODE ELECTRICAL CODE FIRE PREVENTION CODE ENERGY CODE ACCESSIBILITY CODE /LAWS BUILDING DATA EXISTING BUILDING CONSTRUCTION NUMBER OF LEVELS OCCUPANCY - EGRESS. CHAPTER 10 MERCANTILE, SALES FLOOR MERCANTILE, STOCK ROOM MERCANTILE, OTHER TOTAL OCCUPANCY EXITS REQUIRED /PROVIDED MAX TRAVEL DIST TO EXIT CITY OF TUKWILA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT CENTER 6300 SOUTHCENTER BLVD, SUITE #100 TUKWILA, WA 98188 (M) MERCANTILE WASHINGTON ST BLDG CODE WAC 51 -50 2009 IBC WAC 51 -52 2009 IMC WAC 51 -57 2009 UPC WAC 51 -11 2009 WASHINGTON ST ENERGY CODE WAC 51 -54 2009 IFC WAC 51 -11 2009 WASHINGTON ST ENERGY CODE ICC /ANSI A117.1 -03 II -B 1 OF 1 SECTION 1004 TABLE 1004.1.1 1,170/30 = 39 OCC 224/300 = 1 OCC 288/100 = 2 OCC 1.682 S.F.= 42 OCC 2 / 2 75 FT THERE WILL BE NO HIGH -PILED STOCK OR RACK STORAGE. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECtivtu. CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER 0 J U WO OW M Ma OR TYPED NAME 05 -22 -12 DATE ISSUED 0' 0 z 0 it OOONo I -' 9 J wLo I op .0 - I- co M 0 DO pot') M ZEN E Z N� W - v O J VI W N =ZW t- Z z ZOX� 0•- -m I ZNM0_�w CO (f) SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: Q W� CD O Z 0 a) 1 D = Z D ILU =-ei Q W cV 0N O : =1 v-) PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: NO SCALE SYMBOLS/ ABBREVIATION CS 2 EXG INSTANTANEOUS WATER HEATER UNDER LAVATORY 1 TOILET ROOM PLAN TYP. X MOD. SCALE: 1/2" = 1' -0" RESTROOM ACCESSORY LEGEND FURNISHED BY CONTRACTOR INSTALLED BY CONTRACTOR EXISTING RESTROOM ACCESSORIES NO. DESCRIPTION MOUNTING DIRECTIONS 0 TOILET PAPER DISPENSER MOUNT AT 15" AFF TO BOTTOM, MIN F2 02 PAPER TOWEL DISPENSER MOUNT AT 48" AFF TO OPERATING MECHANISM F6 03 AIR FRESHENER MOUNT AT 72" AFF ® SOAP DISPENSER MOUNT AT 40" AFF TO BOTTOM 0 SANITARY NAPKIN DISPOSAL MOUNT AT 18" AFF TO BOTTOM 6 H.C. GRAB BARS MOUNT HORIZ AT 33 " -36" AFF 7 MIRROR MOUNT AT 40" AFF TO BOTTOM OF MIRROR ® BABY CHANGING STATION MOUNT AT 40" AFF TO BOTTOM OF STATION ACCESSIBLE RESTROOM SIGNAGE at 0 ca CO 18" MAX w -J O ro 0 / / / / / / / } 8" WHITE LETTERS AND FIGURE ON BLUE FIELD W/ NO —GLARE FINISH. RAISED BRAILLE AT BOTTOM OF SIGN. MOUN11NG LOCATION AND HEIGHT WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH SECTION 1117B.5.6. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE BETWEEN 48 INCHES MIN (1291.2 MM) AND 60 INCHES MAX (1524 MM) ABOVE THE FINISHED FLOOR TO THE BOTTOM OF THE RAISED BRAILLE. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES (76 MM) WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. TOILET ROOM ACCESS. NOTE: TOILET ROOM SHALL CONFORM TO ACCESSIBILITY REQUIREMENTS, INCLUDING BUT NOT UMITED TO THE FOLLOWING: - GRAB BAR DIAMETER: 1 1/2". — SPACE BETWEEN GRAB BAR AND WALL: 1 1/2". LAVATORY DEPTH: 17" MIN. — INSULATE EXPOSED LAVATORY SUPPLY AND WASTE PIPES. — INTERNATIONAL ACCESSIBILITY SYMBOL SHALL BE MOUNTED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. — REMOVE ACCESSORIES AS REQUIRED FOR INSTALLATION OF NEW FINISHES. INSTALL NEW OR REINSTALL EXG ACCESSORIES AS SCHEDULED. WALL TYPES LEGEND TYPE I DESCRIPTION EXISTING METAL STUDS AND GYP BD TO REMAIN. PATCH AND REPAIR AS REQUIRED FOR INSTALLATION OF NEW FINISHES. 3 5/8" METAL STUDS TO DECK. 5/8" TYPE 'X' GYP BD TO 6" ABOVE CEILING HEIGHT. 9" X 3/4" FRT PLYWOOD 0 MOUNTING LOCATIONS ONLY BEHIND WALL STANDARDS, SEE ELEVATIONS & 10/A -2. PROVIDE SECURITY MESH FROM FLOOR TO UNDERSIDE OF DECK ABOVE — SEE SPEC, SHEET/1 AND DETAIL 2/A -2. PROVIDE SECURITY MESH OVER EXG GYP BD FROM FLOOR TO UNDERSIDE OF DECK ABOVE. PROVIDE 5/8" TYPE 'X' GYP BD OVER SECURITY MESH TO 6" ABOVE CEIUNG HEIGHT — SEE SPEC, SHEET A—)4" AND DETAIL 1 /A -2. 7 E2 S3 F2 F4 F5 F6 NOTES SEE SHEET A -4 FOR CEIUNG HEIGHTS. SEE SPECIFICATIONS FOR STUD SPACING. TOP AND BOTTOM TRACK TO MATCH STUD GAGE. NOTE: 1. PROVIDE 6 MIL CLEAR SAFETY FILM TO INTERIOR SIDE OF ALL GLAZING. MANUFACTURER TO BE 3M OR APPROVED EQUAL, TYP. 2. PROVIDE WINDOW TINT TO INTERIOR SIDE OF ALL SOUTH FACING GLAZING. TINT TO BE LLUMAR WINDOW FILM N1050 SR CDF NEUTRAL OR APPROVED EQUAL, TYP. GENERAL NOTES 1. ROOM DIMENSIONS ARE INSIDE WALL CLEAR. 2. GENERAL CONTRACTOR TO INSTALL FIXTURES FURNISHED BY BBM. 3. REFER TO ELECTRICAL DRAWINGS TO DETERMINE LOCATION OF CONDUIT (INCLUDING LOW VOLTAGE). 4. INSTALL CORNER GUARDS ON UNPROTECTED OUTSIDE CORNERS. REF 3/A -2. 5. PROVIDE DEEP LEG TOP TRACK NOT FASTENED TO STUDS TO ALLOW FOR VERTICAL EXPANSION OF WALL & ROOF STRUCTURE. PROVIDE EXPANSION JOINTS AS REQUIRED TO PREVENT CRACKS IN WALLS. 6. PROVIDE HORIZONTAL BRACING AT TOP OF WALLS AS NEEDED AT FREE STANDING LOW PARTITION WALLS. 7. ENCLOSE UMITS OF CONSTRUCTION FROM FLOOR TO DECK PROVIDING AIR —TIGHT SEAL AT TOP AND SEAMS, PREVENTING PASSAGE OF DUST & FUMES. 8. COORDINATE CONSTRUCTION BARRICADE INSTALLATION AND "COMING SOON" SIGNAGE WITH MALL OPERATIONS AND BBM. 9. NEW CASHWRAPS SHALL BE ACCESSIBLE. 10. GC TO SCAN JOB SITE CONSTRUCTION DOCUMENT SET WITH ORIGINAL MARKUPS AND FORWARD ELECTRONIC FILES TO ARCHITECT AT COMPLETION OF PROJECT. LEAVE CONSTRUCTION DOCUMENTS IN 4" PVC PIPE MOUNTED TO WALL NEAR ELECTRICAL PANELS. USE STICKER LETTERS AND LABEL TO READ "BBYM AS BUILTS ". 11. ALL FIRE EXTINGUISHERS TO BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. EXG 1X4 FLUORESCENT LIGHT FIXTURES. CLEAN /RELAMP, TYP. REMOVE HVAC DIFFUSER. EXG 2X4 FLUORESCENT UGHT FIXTURES. CLEAN/RELAMP, TYP. APPROXIMATE LOCATION OF EXG RTU. RELOCATE EXG T —STAT. HVAC DIFFUSER, TYP. SPRINKLER HEAD, TYP. HVAC RETURN AIR GRILLE, TYP. z 0 U) z w w z J w cn EXG TOILET ROOM FIXTURES, FLOORING AND CEILING TO REMAIN. CLEAN TO "UKE —NEW" CONDITION. PATCH /REPAIR/REPLACE AS REQUIRED. REMOVE 2X4 LIGHT FIXTURES AS SHOWN AND RETAIN FOR TREE-- �U�-SE.�E. ��--�II� KI5261 NT TEL L RELOCATE EXG ELEC EQUIP. REMOVE TIME CLOCK AND RETAIN FOR RE —USE, SEE ELEC. 0 r - -- a / .• 7"7 r - - -� I / I / IE '_.\ I/ III �1S L_____J / I C: I/ I /1 /I I 5 D /I /I / / / / ^: L— F1 A • 1- PATTERN INDICATES AREA TO REMOVE EXG 2X4 ACT AND GRID. COORDINATE WITH 3/A1 AND A4 SHEET. SMOKE DETECTOR, TYP. EXG 2X4 ACT TO REMAIN PR PARE SURFA ES FOR INTTALLA11ON 0 E NEW FINISHES LAND FIXTURES. s 4 6 86' -4 1/4" iI ` ij LEASEUNE DIMENSION EXIT SIGN W/ EM LIGHTS, TYP. 2 DEMO PLAN TYP. X MOD. SCALE: 1/4" = 1' -0" CNI 03 EXG DEMISING WALL MAINTAIN 1 —HR RATING. 6' -5 1/4" 75' -0 /4" 3' -4 1/2" .4.110/1/ Mil l k AM1.� HI/LOW DRINKING FOUNTAIN, SEE A -7 RELOCATED T —STAT 0 48" AFF. 24" X 24" 1/2" FRT PLYWD PHONE BD OVER SERVER. BOT 5' —O" AFF. (INSTALL PHONE BD WITHIN FIRST WEEK OF CONSTRUCTION) OILET ROOM 1 >" 103 1 I \52 SF OUTSIDE CORNER HALLWAY 2 107 I I - - - - - - L� — SALES 1,170 SF EXG ELECTRICAL PANELS SEE ELEC. 20" X 20" X 1/2" FRT PLYWD BACKER FOR SECURITY PANEL BOT 0 5' -0" AFF REFER ELEC. OFFICE STOCK td- - -L— - - - - -�— 1 I IF— I I I I—�I I— — — — — — — — ALL J � JI— —1i I—= // /' 1/////, "I", /3 HALLWAY 1 EXG DEMISING WALL MAINTAIN 1 —HR RATING. SECURITY KEYPAD MOUNTED 5' -0" AFF PROVIDE STEP LADDER, SEE SPEC 86' -4 1/4" LEASEUNE DIMENSION D REVIEWED FOR ,}DE COMPLIANCE APPROVED 1 JUN 13 2012 City of Tukwila BUILDING DIVISION RECbvtu CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER 3 FLOOR PLAN TYP. X MOD. SCALE: 1 /4" = 1' -0" 0 CC U w U m w z Z CI I- t- 0 0 0 w I- z a 05 -22 -12 DATE ISSUED U, 0 z 0 Li Onrn co 0 E w i I o1I _c — - I— 00M O D 5 MM D CO zr,NE z U W vg v o v 0_ tnOJ W N O 2ZW J -7 1-1-1 z Q �OCZ0 ZNL�tai_ 01 SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: a- IY O Q z 0 2wO- I— C) D Q N (/) (/) � F— PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED DEMOLITION AND FLOOR PLANS A -1 EXG STRUCTURAL DECK STEEL STUD FRAMING 0 16" OC (ICC —ES #4943P) W /GYP BD EACH SIDE EXG 1 —HR FIRE RATED DEMISING WALL. DOOR SCHEDULE NO. DOOR FRAME HDWR GROUP REMARKS NO. ROOM TYPE OPENING SIZE MATERIALS FINISH TYPE MATL. FINISH 101 SALES EXG EXISTING EXG — — — — 1 2 102 OFFICE /STOCK B 3' -0" x 7' -0" MTh PT -2 (C -1) HM -1 MTh PT -2 (C -1) 2 VB -1 103 TOILET ROOM EXG EXISTING EXG PT -2 (C -1) EXG EXG PT -2 (C -1) 4 1 104 SERVICE CORRIDOR EXG EXISTING EXG PT -2 (C -1) EXG EXG PT -2 (C -1) 3 2, 3, 4 NOTES: PER ACCESSIBILITY CODE. ACCEPT INTERCHANGEABLE SCHLAGE CORE, REPLACE AS REQUIRED. AND DOOR PER MALL REQ. SUITE NUMBER ON REAR DOOR. COORDINATE WITH LL AND BBYM. 1. MOUNT ACCESSIBLE SIGNAGE 2. VERIFY EXG CYLINDER WILL 3. PAINT CORRIDOR SIDE FRAME 4. PROVIDE STORE NUMBER AND PROVIDE SECURITY MESH FROM FLOOR TO UNDERSIDE OF DECK ABOVE ON STOCKROOM SIDE ONLY. PROVIDE 5/8" TYPE 'X' GYP BD TO 6" ABOVE FINISHED CEILING. 1 -1/4" DEEP TRACK TO MATCH STEEL STUDS W/ HILTI X —U POWER DRIVEN FASTENERS 24" OC. (ICC —ESR #2269) 1 1/4" DEEP STEEL TRACK WITH (2) #10 TEK SCREWS (1 PER SIDE) 0 EA 16" OC STUD (ICC —ES #1976). 'NOTE: PROVIDE ANCHORAGE AS SHOWN FOR ALL INTERIOR WALL PARTITIONS UNO. WIRE MESH AT EXG PARTITION SCALE: 3" = 1' -0" EXG CONC SLAB HARDWARE SCHEDULE NO. HARDWARE GROUP #1 1 EA HARDWARE GROUP #3 EXG PR 1 EA 1 EA 1 EA 1 EA 1 EA EXG FRONT ENTRY: MORTISE CYLINDER, CONSTRUCTION KEYED, SCHLAGE FORMAT HINGES DETEX ECL -230D CLOSER DOOR VIEWER — ROCKWOOD 620 KICKPLATE 10" x 34" LATCH GUARD 78 "— TCH #214300 HARDWARE GROUP #2 1 1/2 PR 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA HINGES SCHLAGE KING COBRA KC5196 OR eBOSS E5400LN OR EQ TO SUPPORT SCHLAGE INTERCHANGEABLE CORE WALL DOOR STOP SILENCERS (INCLUDED IN FRAME) KICKPLATE 10" x 34" CLOSER (MOUNTED TO STORAGE SIDE) DOOR VIEWER — ROCKWOOD 620 HARDWARE GROUP #4 EXG PR 1 EA EXG EA EXG EA HINGES YALE 5303LN PRIVACY LOCKSET OR SCHLAGE EQ CLOSER KICKPLATE 10" x 34" NOTES: CORE. ALL LOCKSETS TO BE CONST KEYED, TO INCLUDE OPERATING KEYS. 1. ALL LOCKSETS TO BE SCHLAGE, ND SERIES INTERCHANGEABLE 2. HARDWARE FINISH TO BE 626 SATIN CHROME PLATED. WALL ANCHOR SCALE: EXG STRUCTURAL DECK ELONGATED PRIMARY RUNNER FASTENED TO DECK W/ #10 TEKS ATTACHED AT 12" OC. SECONDARY RUNNER FRICTION FIT SECONDARY RUNNER IN PRIMARY RUNNER. PROVIDE SECURITY MESH FROM FLOOR TO UNDERSIDE OF DECK ABOVE ON STOCKROOM SIDE ONLY. 1, SEE X SCHED TYPE: HM -1 HOLLOW METAL FRAME DOOR AND FRAME TYPES w w 0 w U J, SEE 1, ' SCHED ' TYPE: B HOLLOW METAL DOOR ROOM FINISH SCHEDULE NO. ROOM FLOOR BASE WALL CEIUNG CEIUNG HTS. REMARKS 101 SALES CA- 1 /MT -1 WD -1 PT -1 (C -1) EXG ACT 9' -11" PT -2 102 OFFICE /STOCK SC -1 VB -1 PT -1 (C -1) EXG ACT 9' -11" VCT 103 TOILET ROOM EXG VCT VB -1 PT -1 (C -1) EXG GYP BD 8' -0" 104 HALLWAY 1 CA -1 VB -1 PT -1 (C -1) EXG ACT 9' -11" 105 HALLWAY 2 CA -1 VB -1 PT -1 (C -1) EXG ACT 9' -11" NOTE: SEE SPECIFICATIONS FOR MANUFACTURER AND MATERIALS. OOnrn E Z N.) (s) v mW, I0 - I- CO r,,.) C.) 5 tM M m cn '—' E Z ^ANN U W (D--"' ' WNp Z Z Q ✓ O)ZOm ZZ a W SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: WIRE MESH AT NEW PARTITION SCALE: 3" = 1' -0" WALL CORNER NOT USED # ## SCALE: CORNER GUARD VINYL OR WOOD BASE ISOMETRIC 4' X 2 1 /2" X 2 1/2", 14 GA CLEAR LEXAN CORNER GUARDS AT 4" AFF AT ALL OUTSIDE CORNERS. ALL EDGES TO BE FILED SMOOTH. MIL STUDS NOT USED SCALE: INSTALLATION: FURNISH AND INSTALL A 4' -0" HIGH LEXAN CORNER GUARD, SCREW ATTACH BEGINNING AT 6" AFF AND AT 20" OC. CORNER DETAIL SCALE: 3" = NOT USED NOT USED SCALE: SCALE: METAL DECK TOP BEAM CLAMP THREADED ROD +aiiwiinu�n.W 1\ EXG BAR JOIST THREADED ROD UNISTRUT WASHER WITH LOCK NUT 9" X 3/4" CONTINUOUS FRT PLYWOOD BLOCKING. USE FRT PLYWOOD WHEN REQUIRED BY CODE. BLOCKING TO EXTEND 3" MIN BEYOND EDGE OF STANDARD, TYP. 5/16" DIA. X 1 /2" GALV. CARRIAGE BOLT AND LOCK NUT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WASHER WITH NUT METAL ANGLE OR UNISTRUT, SECURE SUPPORT STRUCTURE TO BAR JOIST WITH APPROVED FASTENER ON BOTH ENDS. (2) #10 TEK SCREWS 0 EA STUD SHELF STANDARD ALLEN HEAD SET SCREW FOR FINAL ADJUSTMENT. ADJUST BOTTOM EXTENSION FOR SPECIFIC HEIGHT. NOTE: ATTACHMENTS ARE ONLY PERMITTED AT TOP CHORD OF EXISTING ROOF JOISTS REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 0 0 2 U J 0 C0 O F- LU m Q 0 WOOD CLEAT, ATTACH TO WALL PER MANUFACTURER'S INSTRUCTIONS. NOTE: ATTACHMENTS ARE ONLY PERMITTED AT TOP CHORD OF EXISTING ROOF JOISTS LARGER EXTENSION TO BE INSTALLED BELOW SMALLER EXTENSION. NOTE: ANCHOR FRT PLYWOOD BLOCKING TO SR STUDS W/ (2) #12 SELF TAPPING SCREWS (1 5/8" MIN LENGTH 0 EA STUD.) City of Tukwila BUILDING DIVISION HEAD/TRIM METAL STUD FRAMING 5/8" TYPE "X" GYP BD PLUGMOLD, SEE ELEC SHEETS WHITE METAL TRIM PIECE, INSTALL PER MANUFACTURER'S INSTRUCTIONS. 1 SLAT WALL SHEET BELOW PLUGMOLD AND 2 SHEETS ABOVE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SCREW TO BE COUNTERSUNK AND MUST PENETRATE METAL STUD, TYP. REGtivtu CITY OF TUKWII.A MAY 302012 PERMIT CENTER BASE /TRIM WOOD CLEAT, ATTACH TO WALL PER MANUFACTURER'S INSTRUCTIONS. ALLOW CLEARANCE FOR UNEVEN FLOORING CONDITIONS. HOLD FIXTURE BASE MAXIMUM 1" OFF FLOOR, TYP 4 JOIST ATTACHMENT DETAIL TYP. X MOD. FIXTURE EXTENSION ATTACH © POS SCALE: N.T.S. SCALE: N.T.S. TYP. X MOD. 1 SHELVING ANCHOR DETAIL SCALE: 6" = 1' -0" TYP. X MOD. 12 SLATWALL SECTION TYP. X MOD. SCALE: 3 "= 1' -0" 0 W Q W F CO W°C) Cn Q Z 0 U W I W O I—UL� (/)(/) I— PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED SCHEDULES, LEGENDS & DETAILS A -2 GO .,....,E ROOM FINISH LEGEND ,f; _._\ ABBREVIATION DESCRIPTION ACT EXISTING 2' X 4' ACT CA -1 CARPET FRP -1 FIBERGLAS REINFORCED PLASTIC PANEL HM -1 HOLLOW METAL DOOR /FRAME MT -1 ENTRY MAT CARPET PT -1 PAINT — GYP BD, SEE A -7 AND SPEC PT -2 PAINT — HM DOORS AND FRAME PT -4 PAINT — WOOD TRIM SC -1 SEALED CONCRETE VB -1 VINYL BASE VCT EXISTING VINYL COMPOSITION TILE WD -1 WOOD BASE NOTE: SEE SPECIFICATIONS FOR MANUFACTURER, MATERIALS, AND FINISHES. OOnrn E Z N.) (s) v mW, I0 - I- CO r,,.) C.) 5 tM M m cn '—' E Z ^ANN U W (D--"' ' WNp Z Z Q ✓ O)ZOm ZZ a W SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: WIRE MESH AT NEW PARTITION SCALE: 3" = 1' -0" WALL CORNER NOT USED # ## SCALE: CORNER GUARD VINYL OR WOOD BASE ISOMETRIC 4' X 2 1 /2" X 2 1/2", 14 GA CLEAR LEXAN CORNER GUARDS AT 4" AFF AT ALL OUTSIDE CORNERS. ALL EDGES TO BE FILED SMOOTH. MIL STUDS NOT USED SCALE: INSTALLATION: FURNISH AND INSTALL A 4' -0" HIGH LEXAN CORNER GUARD, SCREW ATTACH BEGINNING AT 6" AFF AND AT 20" OC. CORNER DETAIL SCALE: 3" = NOT USED NOT USED SCALE: SCALE: METAL DECK TOP BEAM CLAMP THREADED ROD +aiiwiinu�n.W 1\ EXG BAR JOIST THREADED ROD UNISTRUT WASHER WITH LOCK NUT 9" X 3/4" CONTINUOUS FRT PLYWOOD BLOCKING. USE FRT PLYWOOD WHEN REQUIRED BY CODE. BLOCKING TO EXTEND 3" MIN BEYOND EDGE OF STANDARD, TYP. 5/16" DIA. X 1 /2" GALV. CARRIAGE BOLT AND LOCK NUT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WASHER WITH NUT METAL ANGLE OR UNISTRUT, SECURE SUPPORT STRUCTURE TO BAR JOIST WITH APPROVED FASTENER ON BOTH ENDS. (2) #10 TEK SCREWS 0 EA STUD SHELF STANDARD ALLEN HEAD SET SCREW FOR FINAL ADJUSTMENT. ADJUST BOTTOM EXTENSION FOR SPECIFIC HEIGHT. NOTE: ATTACHMENTS ARE ONLY PERMITTED AT TOP CHORD OF EXISTING ROOF JOISTS REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 0 0 2 U J 0 C0 O F- LU m Q 0 WOOD CLEAT, ATTACH TO WALL PER MANUFACTURER'S INSTRUCTIONS. NOTE: ATTACHMENTS ARE ONLY PERMITTED AT TOP CHORD OF EXISTING ROOF JOISTS LARGER EXTENSION TO BE INSTALLED BELOW SMALLER EXTENSION. NOTE: ANCHOR FRT PLYWOOD BLOCKING TO SR STUDS W/ (2) #12 SELF TAPPING SCREWS (1 5/8" MIN LENGTH 0 EA STUD.) City of Tukwila BUILDING DIVISION HEAD/TRIM METAL STUD FRAMING 5/8" TYPE "X" GYP BD PLUGMOLD, SEE ELEC SHEETS WHITE METAL TRIM PIECE, INSTALL PER MANUFACTURER'S INSTRUCTIONS. 1 SLAT WALL SHEET BELOW PLUGMOLD AND 2 SHEETS ABOVE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SCREW TO BE COUNTERSUNK AND MUST PENETRATE METAL STUD, TYP. REGtivtu CITY OF TUKWII.A MAY 302012 PERMIT CENTER BASE /TRIM WOOD CLEAT, ATTACH TO WALL PER MANUFACTURER'S INSTRUCTIONS. ALLOW CLEARANCE FOR UNEVEN FLOORING CONDITIONS. HOLD FIXTURE BASE MAXIMUM 1" OFF FLOOR, TYP 4 JOIST ATTACHMENT DETAIL TYP. X MOD. FIXTURE EXTENSION ATTACH © POS SCALE: N.T.S. SCALE: N.T.S. TYP. X MOD. 1 SHELVING ANCHOR DETAIL SCALE: 6" = 1' -0" TYP. X MOD. 12 SLATWALL SECTION TYP. X MOD. SCALE: 3 "= 1' -0" 0 W Q W F CO W°C) Cn Q Z 0 U W I W O I—UL� (/)(/) I— PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED SCHEDULES, LEGENDS & DETAILS A -2 GO CA -1 JOHNSONITE CARPET TO TILE REDUCER EG -40 -G BLACK. SEE SPEC. SLOPE NOT TO EXCEED 1:2 SC -1 :y . i : CA -1 JOHNSONITE CARPET TO TILE REDUCER CTA -40 -H BLACK SLOPE NOT TO EXCEED 1:2 VCT -1I PROVIDE LATEX LEVELING COMPOUND AS REQ'D TO CREATE FLUSH CONDITION AT THRESHOLD. 1/2" ✓MAX 1 SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. 4 CA -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: 3/4" = 1' -0" MT -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: N.T.S. EXG VINYL TILE TO REMAIN. PATCH /REPAIR /REPLACE AS REQUIRED I VCT -1I SC -1 r // / /% /% /; / / // / /d / /// //, /. G/ r' ///% % / //// / /i / // / / / % / / /% /,, /,, / //j . `' • / o' ' • . / / / -:r. . - _ .r • • • I CA -1 I 2 FLOOR FINISH PLAN TYP. X MOD. SCALE: 1/4 = 1 ' -0 I) a FLOOR FINISH LEGEND MT -1 //�/ FJ • F. SC -1 VCT CARPET ENTRY MAT CARPET EXG CONC PROVIDE SEALED FINISH EXG VINYL COMPOSITION TILE NOTES 1. SEE ROOM FINISH LEGEND ON SHEET A -2 FOR DETAIL DESCRIPTION OF MATERIALS. 2. FLOAT FLOOR AS REQ'D TO PROVIDE A SMOOTH /FLUSH FINISH CONDITION. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECtivtu CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER 0 J 0 W 0 CO W Z 0 W a >- 0 O O W a 05 -22 -12 DATE ISSUED 0 Z C, W z 0 J 0: a 0 �OOnrn i—'cool U J Wln I alo -C ; 5 M ) 0L. z� E z C'4 U � � � WH - WNQ IZW J rrnZO 2 X z a_ Lii_ W mtn SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: 0 >- 0 W Q W DD H DD Qr Z CO U Et 0= H IT Z O V) U IZ w W J —U u7: 0 N O PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED FLOOR FINISH PLAN A -3 T T T 1 T T E- T I T T E- 1 E- T 1 SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. 4 CA -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: 3/4" = 1' -0" MT -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: N.T.S. EXG VINYL TILE TO REMAIN. PATCH /REPAIR /REPLACE AS REQUIRED I VCT -1I SC -1 r // / /% /% /; / / // / /d / /// //, /. G/ r' ///% % / //// / /i / // / / / % / / /% /,, /,, / //j . `' • / o' ' • . / / / -:r. . - _ .r • • • I CA -1 I 2 FLOOR FINISH PLAN TYP. X MOD. SCALE: 1/4 = 1 ' -0 I) a FLOOR FINISH LEGEND MT -1 //�/ FJ • F. SC -1 VCT CARPET ENTRY MAT CARPET EXG CONC PROVIDE SEALED FINISH EXG VINYL COMPOSITION TILE NOTES 1. SEE ROOM FINISH LEGEND ON SHEET A -2 FOR DETAIL DESCRIPTION OF MATERIALS. 2. FLOAT FLOOR AS REQ'D TO PROVIDE A SMOOTH /FLUSH FINISH CONDITION. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECtivtu CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER 0 J 0 W 0 CO W Z 0 W a >- 0 O O W a 05 -22 -12 DATE ISSUED 0 Z C, W z 0 J 0: a 0 �OOnrn i—'cool U J Wln I alo -C ; 5 M ) 0L. z� E z C'4 U � � � WH - WNQ IZW J rrnZO 2 X z a_ Lii_ W mtn SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: 0 >- 0 W Q W DD H DD Qr Z CO U Et 0= H IT Z O V) U IZ w W J —U u7: 0 N O PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED FLOOR FINISH PLAN A -3 T T T E- T T T E- 1 SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. SEALED CONCRETE TO VINYL TILE TYP. X MOD. SCALE: N.T.S. 4 CA -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: 3/4" = 1' -0" MT -1 CARPET TILE INSTALL PATTERN TYP. X MOD. SCALE: N.T.S. EXG VINYL TILE TO REMAIN. PATCH /REPAIR /REPLACE AS REQUIRED I VCT -1I SC -1 r // / /% /% /; / / // / /d / /// //, /. G/ r' ///% % / //// / /i / // / / / % / / /% /,, /,, / //j . `' • / o' ' • . / / / -:r. . - _ .r • • • I CA -1 I 2 FLOOR FINISH PLAN TYP. X MOD. SCALE: 1/4 = 1 ' -0 I) a FLOOR FINISH LEGEND MT -1 //�/ FJ • F. SC -1 VCT CARPET ENTRY MAT CARPET EXG CONC PROVIDE SEALED FINISH EXG VINYL COMPOSITION TILE NOTES 1. SEE ROOM FINISH LEGEND ON SHEET A -2 FOR DETAIL DESCRIPTION OF MATERIALS. 2. FLOAT FLOOR AS REQ'D TO PROVIDE A SMOOTH /FLUSH FINISH CONDITION. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECtivtu CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER 0 J 0 W 0 CO W Z 0 W a >- 0 O O W a 05 -22 -12 DATE ISSUED 0 Z C, W z 0 J 0: a 0 �OOnrn i—'cool U J Wln I alo -C ; 5 M ) 0L. z� E z C'4 U � � � WH - WNQ IZW J rrnZO 2 X z a_ Lii_ W mtn SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: 0 >- 0 W Q W DD H DD Qr Z CO U Et 0= H IT Z O V) U IZ w W J —U u7: 0 N O PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED FLOOR FINISH PLAN A -3 MAIN HANGER WIRE 0 4' -0" OC. 12 GA MIN. DIAGONAL WIRE BRACING 0 12' -0" OC. IN (4) DIRECTIONS. 12 GA MIN. MAIN RUNNERS 0 4' -0" OC. ACT -11 it ACT CEILING DETAIL SCALE: 3" = 1' -O" PROVIDE 1 /2" FRT PLYWOOD WITH TIGHT FIT OVER FIXTURE EXTENSION ABOVE ACT, TYP. ALUM FIXTURE EXTENSION TO BE 7 PLUMB AND TRUE ACT -1 z co TABLE FIXTURE EXTENSION DETAIL NOTE: VERIFY EXACT LOCATION W /BBYM MERCHANDISING PLAN. LOCATION VARIES EXTENSION - LOCATED AT POWER DROP CEIUNG ABOVE R CO E EQ LIGHTING DETAIL J BOX MOUNTED TO U CHANNEL "U" CHANNEL ASSEMBLY FURNISHED W /TABLE VALANCE ATTACH TRACK TO VALANCE "U" CHANNEL VALANCE B.O. VALANCE O 7` -0" AFF TRACK HEAD TABLE LEG /SUPPORT PENDANT LIGHT FIXTURE B.O. PENDANT O 5' -6" AFF EXISTING 2'x4' ACT SYSTEM TO REMAIN. REPLACE DAMAGED, BROKEN OR STAINED TILES TO MATCH EXISTING. SPEAKERS AND BRACKET FURNISHED BY BBYM. BRACKET INSTALLED BY GC. EXISTING 2'x4' ACT SYSTEM TO REMAIN. REPLACE DAMAGED, BROKEN OR STAINED TILES TO MATCH EXISTING. 5-4 1 /2" EXG GYP_ . BD CEIUNG 0 8 -0 AFF EXG TOILET EXHAUST FAN, CLEAN AND REPAIR TO "LIKE -NEW" CONDITION. ".4/7"/,'‘ ADJACEN'T""'P:ENANT RELOCATE EXG 2'x4' LIGHTS AS SHOWN. CLEAN AND RELAMP, TYP. EXG 2' X 4' ACT CLG SHOPPER TRAK- SEE ELECTRICAL FOR LOCATION AND INFORMATION 2' X 2' LIGHTS, REFER ELEC, TYP. ,,,,,r0 % %%% EXG 2' X 4' ACT CLG O 9 -11 AFF 52" STACKED ILLUMINATED CHANNEL LETTER SIGNAGE ABV PROVIDED BY BBM SIGN VENDOR. BEST BUY MOBILE FURNISHED, GC INSTALLED WIRE WINDOW DISPLAY TRACK LIGHT, CENTER TRACK ON FIXTURE RUN, DIRECT UGHTS TOWARDS FIXTURE. REFER ELEC, TYP TRACK TO BE MOUNTED TO VALANCE "U" CHANNEL FIXTURE VALANCE ATTACHED TO TABLE LEG EXTENSIONS REFLECTED CEILING PLAN SCALE: 1/4 = 1' -0 GENERAL NOTES 1. REFER TO ELECTRICAL SHEETS FOR ADDITIONAL DETAILS AND INFORMATION. 2. HORN /STROBES, EXIT LIGHTS, EMERGENCY LIGHTS, ELECTRICAL BOXES FOR SIGNS, ETC SHALL NOT BE INSTALLED IN WALL GRAPHICS, BUT DIRECTLY BELOW WALL GRAPHICS. COORDINATE WITH INTERIOR ELEVATIONS ON THE ARCHITECTURAL SHEETS AND FIXTURE PLANS. 3. ADDITIONAL EMERGENCY BATTERY LIGHTING HEADS, EMERGENCY BATTERY EXITS, OR ADJUSTMENTS THAT ARE REQUIRED BY THE AHJ WILL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 4. USE PLENUM RATED CABLE, CONDUIT, BOXES, ETC. IN PLENUM RATED WALLS AND CEILINGS. COMPLETELY SEAL PENETRATIONS. 5. RUN MECHANICAL AND ELECTRICAL EQUIPMENT, CONDUIT, AND DUCT WORK AS HIGH AS POSSIBLE. COORDINATE WORK WITH ALL TRADES BEFORE PROCEEDING. 6. CONDUITS, RACEWAYS, ELECTRICAL DUCTS AND BOXES, AND EXPOSED LOW VOLTAGE WIRE SHALL BE RUN TRUE, PLUMB, SQUARE TO BUILDING, TIGHTLY WRAPPED OR FASTENED TO STRUCTURE. LOW VOLTAGE RUNS OR EXPOSED WIRE MUST BE HIDDEN FROM VIEW AND TIE WRAPPED TO THE STRUCTURE WIN WHITE WRAPS. WRAPS TO BE UNIFORMLY SPACED WITH ENOUGH WRAPS TO PREVENT SAGGING. DO NOT RUN WIRE IN FREE OR ON DIAGONALS. 7. ELECTRICAL DEVICES SHALL BE RECESSED AND AND CONDUITS CONCEALED UNLESS OTHERWISE APPROVED BY BBM. 8. HANGING ITEMS SUSPENDED FROM CEIUNG TO BE HUNG IN FLUTE OF THE DECK ABOVE TOP CHORD OF JOIST USING UNISTRUT SIZED PER DETAIL OR INDICATED OTHERWISE BY STRUCTURAL ENGINEER. 9. GENERAL CONTRACTOR RESPONSIBLE FOR ALTERATION OF FIRE PROTECTION TO BE DEFERRED SUBMITTAL BY A UCENSED SPRINKLER CONTRACTOR IN THE STATE OF WASHINGTON UNDER SEPARATE COVER. SPRINKLER HEADS TO BE SEMI - RECESSED CHROME. 10. LIGHTS BEING REUSED TO BE CLEANED THOROUGHLY AND RELAMPED WITH SAME COLOR LAMP. 11. GENERAL CONTRACTOR RESPONSIBLE FOR CONNECTION AND /OR ALTERATION OF FIRE ALARM SYSTEM AND TO BE A DEFERRED SUBMITTAL, IF REQUIRED, BY A UCENSED FIRE ALARM CONTRACTOR IN THE STATE OF WASHINGTON UNDER SEPARATE COVER. RCP SYMBOLS LEGEND SYMBOL DESCRIPTION TRACK HEAD AND TRACK ° 2' X 2' LAY -IN FLUORESCENT FIXTURE ■■■ sm. 1' X 4' FLUORESCENT FIXTURE FIX 4' FLUORESCENT FIXTURE Z EMERGENCY EXIT UGHT SURFACE (UNIVERSAL) EMERGENCY FLOOD LIGHT FIXTURE EXTENSION SPEAKER t:i; NOTE: AND ELECTRICAL SHEETS INFO. SEE MECHANICAL FOR ADDITIONAL REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECtivti! CITY OF TUKVviLA MAY 3 0 2012 PERMIT CENTER Z O J 0 w U CO w z z EL ce 0 0 0 I- z 05 -22 -12 DATE ISSUED 0 0 LI C.,...) _ w V w = c.i «z ▪ z z Z oZ J o- Q V w w I- = J: U m a a z 0 U) CC a 0 w 0 m �OOnrn ZP')'fCOC, E (ON JWtnl -c — F_— aD M U D 5 MM a y'z ^E zN .(0- -0 I- W In._ ho- 2Zw J 1- Z Z Q �o)ZOjM ZZ C Q LL W VS SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: # ## 0 < W DO : I— aD a Z O 0 Q N W U :7° o N= PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED REFLECTED CEILING PLAN A -4 STRUCTURE ABV WIRE MESH, REFER A -1.g SHEET NOTE: NO PLUGMOLD AT REAR SLATWALL BOARD. C -1 C -1 DO WV (ENTIRE WALL) C -1 BBM BRAND WALL NON- ILLUMINATED SIGNAGE FURNISHED AND INSTALLED BY BBM SIGN VENDOR. OT.O. GLAZING 0 9' -6" AFF I PT -1 I C -1 RELOCATED T -STAT 0 48" AFF. SALES (REAR) SCALE: 1/4" = 1' -0" WD-1 PT-4 C -1 U- > OPEN 3 V ---------i--__ STRUCTURE ABV ACT T.O. GLAZING 0 8' -4" AFF EXG STOREFRONT GLAZING, FRAMING AND ENTRY DOORS TO REMAIN, TYP. WIRE WINDOW DISPLAY I PT -1 I C -1 WD-1 PT-4 C -1 SALES (FRONT) SCALE: 1/4" = 1' -0" U- SERVER I VB -1 I - -� .............. .............. ••••••■••••••• .............. .............. .............. .............. .u........... .............. mummosiaans •••• .............. MBE= ••••••••• .............. .............. .............. .............. .............. .............. •••••••••••••• .............. .............. .............. .............. .............. ............. .............. .............. .....u....... .............. .............. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ LIJ .............. .............. .............• .............. .............. .............. .............. .............. .............. .............. .............. • N STOCK ROOM (REAR) SCALE: 1/4" = 1' -0" iE 4' -0" �,2' -0 "�, OC OC ' STRUCTURE ABV WIRE MESH, REFER A-i.g SHEET 3 I ACT I INSTALL EXTENSIONS AS NECESSARY TO ACHIEVE HEIGHT. 8' SECTION STARTS AT FLOOR. (5) 9" BANDS OF 3/4" N\ BLOCKING BEHIND o STORAGE FIXTURE, TYP. I SEE FIXTURE PLAN FOR ADDITIONAL INFO. BLOCKING TO EXTEND 3" MIN BEYOND EDGE OF STANDARD, TYP N N I + N > EXG TOILET PAPER DISPENSER TOILET ROOM (REAR) SCALE: 1/4" = 1' -0" PT -1 C -1 OPEN V ' \ STRUCTURE ABV EXCEPT BEHIND PT -1 FIXTURES. UNO C -1 ACT I SALES (LEFT) SCALE: 1/4" = 1' -0" NOTE: PAINTING IS NOT REQ BEHIND WALL FIXTURES IN SALES AREA. PAINT VISIBLE WALL AREA ONLY. NOTE: COORDINATE LOCATION OF 24 "X24" ACCESS PANELS WITH SIGNAGE VENDOR FOR PREFERRED LOCATION, IF REQ. NOTE: 1. PROVIDE 6 MIL CLEAR SAFETY FILM TO INTERIOR SIDE OF ALL GLAZING. MANUFACTURER TO BE 3M OR APPROVED EQUAL, TYP. 2. PROVIDE WINDOW TINT TO INTERIOR SIDE OF ALL SOUTH AND SOUTH -WEST FACING GLAZING. TINT TO BE LLUMAR WINDOW FILM N1050 SR CDF NEUTRAL OR APPROVED EQUAL, TYP. C -1 SANITARY NAPKIN DISPOSAL TOILET PAPER DISPENSER EXG VB -1 TOILET ROOM (LEFT) SCALE: 1/4" = 1' -0" N) 2f- APT -1I C -1 CP.1 FIXTURE 4'X4' GRAPHIC FRAME FURNISHED BY BBM AND INSTALLED BY GC. WD-1 PT-4 C -1' PAINT VISIBLE WALL AREA BELOW FIXTURE U- STRUCTURE ABV WIRE MESH, REFER A -1.2 SHEET .J PT-1 I ACT I 24" X 24" 1/2" PLYWD PHONE BD OVER SERVER. BOT 0 5' -0" AFF. (INSTALL PHONE BD WITHIN FIRST _ WEEK OF CONSTRUCTION) m SERVER VB -1 I STOCK ROOM (LEFT) SCALE: 1/4" = 1' -0" \ 0 N NOTE: PATCH /REPAIR WALLS AND CLG AS REQ THROUGHOUT TOILET ROOM. PT -1 C -1 NOTE: REFER SHEET A -1 FOR ACCESSORY MOUNTING HEIGHTS. I PT -1 I C -1 4'X4' GRAPHIC FRAME FURNISHED BY BBM AND INSTALLED BY GC. WD -1 PT -4 C -1 / OPEN STRUCTURE ABV I ACT I SALES (RIGHT) SCALE: 1/4" = 1' -0" PT -2 C -1 / EXCEPT BEHIND PT -1 FIXTURES. UNO C -1 PAINT VISIBLE WALL AREA BELOW FIXTURE I PT -1 I C -1 a) C -1 + 03 N 4'-0" OC 4, -0" OC STOCK ROOM (FRONT) SCALE: 1/4" = 1' -0" AIR FRESHENER I PT -1 I C -1 PAPER TOWEL DISPENSER I FRP ) 0 EXG 00 PT -2 C -1 I VB -1 I TOILET ROOM (FRONT) SCALE: 1/4" = 1' -0" 4' -0" 4' -0" OC OC C -1 20" X 20" X 1/2" PLYWD BACKER FOR SECURITY PANEL BOT 0 5' -0" AFF. REFER TO ELEC. > TOILET ROOM (RIGHT) SCALE: 1/4" = 1' -0" STRUCTURE ABV WIRE ,MESH, REFER A -1.' SHEET 3' I PT -1 I C -1 I ACT I 03 N PROVIDE (5) COAT HOOKS ON 6" X 5' -0" WD BACKING, SPACED EVENLY a) STOCK ROOM (RIGHT) SCALE: 1/4" = 1' -0" 4' -0" (FRP) ' 0 0_ U- -B' O O O O U- > REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION HI /LOW DRINKING FOUNTAIN IFRP -1I RECtivtt. I FTUKWILA HI /LOW DRINKING FOUNTA 0 0 3 2 12 SCALE: 1/4" = 1' -0" PERMIT CENTER 0 N J U w U ce ce m z z Ca W a ce 0 O 0 z CC 05 -22 -12 DATE ISSUED a, 0 z CC F-- Z U �? w w U z Z z 0 Cntf Q V w Li! W U —U mQm 0OOnrn E Z rr) ED rn 0 � 'D T U JWl() I I -F- OD03 D5 MM Z RE Z :mNN W0 `D °� V? " WNa. = Z W ~ ZZ Q f O Z O X M ZN2a w m� SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1 ,682 SF CONCEPT: 1 .0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUMBER: 0 W < LLI LA) F--- 00 W 00 c w co OI Z 0 W 4(i) Iwo I— O Ln 0 Q cV PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED INTERIOR ELEVATIONS A -7 PT -1 C -5 (GYP BD SOFFIT) 4 2'X4' GRAPHIC FRAME FURNISHED BY BBM AND INSTALLED BY GC. \ ° I WD -1 I PT -41 SALES (LEFT) SCALE: 1/4" = 1' -0" NOTE: PAINTING IS NOT REQ BEHIND WALL FIXTURES IN SALES AREA. PAINT VISIBLE WALL AREA ONLY. NOTE: COORDINATE LOCATION OF 24 "X24" ACCESS PANELS WITH SIGNAGE VENDOR FOR PREFERRED LOCATION, IF REQ. NOTE: 1. PROVIDE 6 MIL CLEAR SAFETY FILM TO INTERIOR SIDE OF ALL GLAZING. MANUFACTURER TO BE 3M OR APPROVED EQUAL, TYP. 2. PROVIDE WINDOW TINT TO INTERIOR SIDE OF ALL SOUTH AND SOUTH -WEST FACING GLAZING. TINT TO BE LLUMAR WINDOW FILM N1050 SR CDF NEUTRAL OR APPROVED EQUAL, TYP. C -1 SANITARY NAPKIN DISPOSAL TOILET PAPER DISPENSER EXG VB -1 TOILET ROOM (LEFT) SCALE: 1/4" = 1' -0" N) 2f- APT -1I C -1 CP.1 FIXTURE 4'X4' GRAPHIC FRAME FURNISHED BY BBM AND INSTALLED BY GC. WD-1 PT-4 C -1' PAINT VISIBLE WALL AREA BELOW FIXTURE U- STRUCTURE ABV WIRE MESH, REFER A -1.2 SHEET .J PT-1 I ACT I 24" X 24" 1/2" PLYWD PHONE BD OVER SERVER. BOT 0 5' -0" AFF. (INSTALL PHONE BD WITHIN FIRST _ WEEK OF CONSTRUCTION) m SERVER VB -1 I STOCK ROOM (LEFT) SCALE: 1/4" = 1' -0" \ 0 N NOTE: PATCH /REPAIR WALLS AND CLG AS REQ THROUGHOUT TOILET ROOM. PT -1 C -1 NOTE: REFER SHEET A -1 FOR ACCESSORY MOUNTING HEIGHTS. I PT -1 I C -1 4'X4' GRAPHIC FRAME FURNISHED BY BBM AND INSTALLED BY GC. WD -1 PT -4 C -1 / OPEN STRUCTURE ABV I ACT I SALES (RIGHT) SCALE: 1/4" = 1' -0" PT -2 C -1 / EXCEPT BEHIND PT -1 FIXTURES. UNO C -1 PAINT VISIBLE WALL AREA BELOW FIXTURE I PT -1 I C -1 a) C -1 + 03 N 4'-0" OC 4, -0" OC STOCK ROOM (FRONT) SCALE: 1/4" = 1' -0" AIR FRESHENER I PT -1 I C -1 PAPER TOWEL DISPENSER I FRP ) 0 EXG 00 PT -2 C -1 I VB -1 I TOILET ROOM (FRONT) SCALE: 1/4" = 1' -0" 4' -0" 4' -0" OC OC C -1 20" X 20" X 1/2" PLYWD BACKER FOR SECURITY PANEL BOT 0 5' -0" AFF. REFER TO ELEC. > TOILET ROOM (RIGHT) SCALE: 1/4" = 1' -0" STRUCTURE ABV WIRE ,MESH, REFER A -1.' SHEET 3' I PT -1 I C -1 I ACT I 03 N PROVIDE (5) COAT HOOKS ON 6" X 5' -0" WD BACKING, SPACED EVENLY a) STOCK ROOM (RIGHT) SCALE: 1/4" = 1' -0" 4' -0" (FRP) ' 0 0_ U- -B' O O O O U- > REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION HI /LOW DRINKING FOUNTAIN IFRP -1I RECtivtt. I FTUKWILA HI /LOW DRINKING FOUNTA 0 0 3 2 12 SCALE: 1/4" = 1' -0" PERMIT CENTER 0 N J U w U ce ce m z z Ca W a ce 0 O 0 z CC 05 -22 -12 DATE ISSUED a, 0 z CC F-- Z U �? w w U z Z z 0 Cntf Q V w Li! W U —U mQm 0OOnrn E Z rr) ED rn 0 � 'D T U JWl() I I -F- OD03 D5 MM Z RE Z :mNN W0 `D °� V? " WNa. = Z W ~ ZZ Q f O Z O X M ZN2a w m� SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1 ,682 SF CONCEPT: 1 .0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUMBER: 0 W < LLI LA) F--- 00 W 00 c w co OI Z 0 W 4(i) Iwo I— O Ln 0 Q cV PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED INTERIOR ELEVATIONS A -7 LEASE LINE 19'— 9" T.O. PARAPET O 32' -4" AFT PAINTED BEST BUY BLUE SIGN BACKGROUND BY GC. COORDINATE SIZE AND LOCATION WITH BBM SIGN VENDOR. All Si e sitio D (V/iawt�I 4thr©M 40#1119M t Si vrmAS T.O. PARAPET O 27-4" AFT LEASE LINE EXG "TAN" EIFS. 77" STACKED ILLUMINATED CHANNEL LETTER SIGN AND TICKET PROVIDED BY BBM SIGN VENDOR. CENTER IN DESIGNATED SIGN AREA. SEPARATE SIGN SUBMITTAL WILL BE SUBMITTED BY SIGN VENDOR. EXG "MUSTARD" EIFS. EXG "BEIGE" EIFS. EXG "WHITE" EIFS. EXG BLACK AND WHITE AWNING. B.O. MALL BULKHEAD O 14' -0" AFF EXG CANOPY. EXG WALL MOUNTED LIGHT FIXTURE. T.O. GLAZING O 9' -6" AFF T.O. GLAZING O 8' -4" AFF DEMISING WALL BEYOND GLAZING. EXG STOREFRONT GLAZING, FRAMING AND ENTRY ! 0! 0 MAIN TYP. NOTE: 1. PROVIDE 6 MIL CLEAR SAFETY FILM TO INTERIOR SIDE OF ALL GLAZING. MANUFACTURER TO BE 3M OR APPROVED EQUAL, TYP. 2. PROVIDE WINDOW TINT TO INTERIOR SIDE OF ALL SOUTH FACING GLAZING. TINT TO BE LLUMAR WINDOW FILM N1050 SR CDF NEUTRAL OR APPROVED EQUAL, TYP. . g EXG BRICK FINISH, TYP. 5611 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION RECEivEU. CITY OF TUKWILA MAY 302012 PERMIT CENTER STOREFRONT ELEVATION SCALE: 3/4" = 1' -0" TYP. MOD. 5449 REGIST. RED BRUCE M. CARLSON +• Z=CT PRINTED OR TYPED NAME VINOV �� � , 1 j 4. BRUCE M. CARLSON DATE ISSUED 05 -22 -12 STATE OF WASHINGTON REG. NO. 5449 1,::::,-;::''''''',' :.: -'7''''' ''.::',-:-,:;',::1 titOAT:::,_..,"'';''''.1,::: '''-..1';'R*-''',-7.;;:l':' '.. 0 ' ''' a '. '' i, ' tgl URI 1 . E Z.: N,_ U v 1 W (OJ W N IZ 2ZW _1 I— Z 0O)ZO7 ZNMa_ 61w SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: 0 < w °p D co Or Z Lu 00 U al rx z 0 =w U Q J PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED STOREFRONT ELEVATION & PLAN A -10 BIDDING REQUIREMENTS MATERIALS SCHEDULE A. MATERIALS RESPONSIBILITY SCHEDULE DIVISION ITEM FURNISHED BY VENDOR INSTALLED BY 08 DOOR HARDWARE GC TWIN CITY HARDWARE GC 08 INTERCHANGEABLE CYLINDERS GC TWIN CITY HARDWARE GC 08 DOORS GC - GC 08 KEYS & CORES BBM TWIN CITY HARDWARE GC 08 ROLLING GRILLE N/A N/A N/A 09 ACT CEILING EXG - EXG 09 CARPET GC LEES CARPET GC 09 WOOD FLOORING (& 1/4 ROUND) N/A N/A N/A 09 FLOORING TRANSITIONS GC - GC 09 PAINT GC - GC 09 WALL BASE GC - GC 09 FRL N/A N/A N/A 10 CORNER GUARDS GC - GC 10 SIGNAGE BBM EVERBRITE EVERBRITE 10 SIGNAGE INSTALLATION BBM - EVERBRITE TEMPLATE 10 FIRE EXTINGUISHERS GC - GC 11 LADDER GC - GC 12 ALL DISPLAY FIXTURES BBM - GC AND CASH WRAPS 12 SAFE BBM - GC 15 MECHANICAL OUTLETS /INLETS GC - GC 15 RTU's (AS NEEDED) GC - GC 16 EMERGENCY EXIT LIGHTS GC - ELECTRICAL CONTRACTOR 16 LIGHTING PACKAGE: INCLUDING GC - ELECTRICAL CONTRACTOR LIGHTS, AND LAMPS 16 SPEAKERS BBM - GC/BBM B. OWNER SUPPLIED MATERIALS CONTACT: LISA MILLER CONSTRUCTION PURCHASING COORDINATOR PHONE: 612 - 291 -7281 FAX: 952 -430 -5314 E -MAIL: lisa.miller @bestbuy.com DIVISION 01 000 - GENERAL REQUIREMENTS SUMMARY A. THE SPECIFICATIONS PORTION OF THIS CONSTRUCTION DOCUMENT INCLUDES THE REQUIREMENTS FOR A TYPICAL BEST BUY MOBILE PROJECT. CONSEQUENTLY THESE SPECIFICATIONS MAY CONTAIN ELEMENTS WHICH DO NOT APPLY TO THIS PARTICULAR PROJECT. THE SCOPE OF WORK FOR THIS PARTICULAR PROJECT IS INDICATED ON THE DRAWINGS. SPECIFICATIONS REQUIREMENTS SHALL APPLY TO ALL WORK INDICATED ON THE DRAWINGS. B. SPECIAL WORK REQUIREMENTS: 1. WORK SHALL BE PHASED SUCH THAT EACH SPECIFIC AREA SHALL BE PROTECTED, DEMOLISHED AND COMPLETED IN THE LEAST AMOUNT OF TIME POSSIBLE. 2. USE OF PREMISES: CONFORM TO THE REQUIREMENTS OF THE BUILDING DEVELOPER/LANDLORD. 3. CONTRACT DOCUMENTS: IN ADDITION TO THE REQUIREMENTS IN THE CLOSE OUT PROCEDURES CONTRACTOR SHALL MAINTAIN ON THE SITE AND WORK FROM FULL -SIZE SETS OF DRAWINGS. HALF -SIZED SETS ARE FOR INFORMATION AND CONVENIENCE ONLY AND MAY NOT BE USED AS A SOURCE OF CONTRACT REQUIREMENTS. C. DEFINITIONS: 1. "FURNISH" MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. 2. "INSTALL" MEANS TO PLACE IN POSITION FOR USE OR SERVICE. 3. PROVIDE" MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE. D. SEPARATE WORK: 1. ITEMS NOTED "NIC" (NOT IN CONTRACT) OR "FOIO" (FURNISHED BY OWNER; INSTALLED BY OWNER) WILL BE FURNISHED AND INSTALLED BY OTHERS. 2. PERFORM WORK SO AS TO ALLOW THE PERFORMANCE OF WORK BY OTHER CONTRACTORS. 3. REFER TO THE RESPONSIBILITY MATRIX ON THE DRAWINGS. E. PRODUCTS FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR (FOIC): 1. COORDINATE WORK TO FACILITATE INSTALLATION OF PRODUCTS FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR. 2. ELEMENTS WHICH ARE FURNISHED BY BEST BUY MOBILE FOR INSTALLATION BY THE CONTRACTOR ARE SHOWN ON THE DRAWINGS. 3. BEST BUY MOBILE RESPONSIBILITIES: a. ARRANGE AND PAY FOR PRODUCT DELIVERY TO SITE. b. SUBMIT CLAIMS FOR TRANSPORTATION DAMAGE. NOTIFY BBM CONSTRUCTION PURCHASING DEPT. (LISA MILLER) AT 612 - 291 -7281. c. ARRANGE FOR REPLACEMENT OF DAMAGED, DEFECTIVE OR MISSING ITEMS. d. ARRANGE FOR MANUFACTURER'S WARRANTIES, INSPECTIONS AND SERVICE. 4. CONTRACTOR'S RESPONSIBILITIES: a. REVIEW SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. b. RECEIVE AND UNLOAD PRODUCTS AT SITE; INSPECT FOR COMPLETENESS, FOR DAMAGE. c. HANDLE, STORE, INSTALL AND FINISH PRODUCTS. d. REPAIR OR REPLACE ITEMS DAMAGED BY WORK OF THIS CONTRACT. F. APPLICATIONS FOR PAYMENT: SUBMIT APPLICATIONS FOR PAYMENT TO THE OWNER PER CONTRACT INSTRUCTIONS. G. COORDINATION: 1. COORDINATE WORK TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTION ELEMENTS, WITH PROVISIONS FOR ACCOMMODATING ITEMS INSTALLED LATER. 2. COORDINATE SPACE REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SYSTEMS. MAKE RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES EFFICIENTLY AND MAXIMIZE ACCESSIBILITY FOR MAINTENANCE, REPAIR AND OTHER INSTALLATIONS. 3. EXECUTE CUTTING AND PATCHING TO INTEGRATE ELEMENTS OF THE WORK. REMOVE ILL -TIMED AND DEFECTIVE WORK AND REPLACE WITH NEW WORK CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 4. UNCOVER DEFECTIVE AND NON - CONFORMING WORK AND FURNISH SAMPLES AS REQUIRED FOR TESTING. 5. SEAL PENETRATIONS THROUGH FLOOR, WALLS AND CEILINGS. H. CONSTRUCTION: 1. SUPERINTENDENT AND / OR CONTRACTOR'S PROJECT MANAGER SHALL SET THE TONE OF THE PROJECT FROM DAY ONE; SENSE OF URGENCY, QUALITY, PROFESSIONALISM, WORK HABITS, HOUSE CLEANING, ORGANIZATIONS SKILLS, ETC. 2. SUPERINTENDENT FROM DAY ONE WILL INSIST ON A CLEAN, SAFE AND ORGANIZED PROJECT. 3. SUPERINTENDENT, CONTRACTOR'S PROJECT MANAGER AND OWNER'S PROJECT MANAGER TO MAINTAIN AN UPDATED FWO (FIELD WORK ORDER LOG) OF CHANGES AND PROGRESS PHOTOGRAPHS OF THE PROJECT TO BE SUBMITTED BY NOON EACH FRIDAY TO THE OWNER'S PROJECT MANAGER. 4. SUPERINTENDENT IS TO ACCURATELY COMPLETE RFI'S (REQUEST FOR INFORMATION) WHEN REQUESTING INFORMATION FROM THE ARCHITECT AND OR CONSULTANTS. THE RFI SHALL BE SPECIFIC IN NATURE AND NOTE WHETHER A COST AND OR TIME EXTENSION IS INVOLVED. THE CONTRACTOR IS ADVISED THAT ONLY AUTHORIZATION FROM THE OWNER'S PROJECT MANAGER WILL PERMIT A COST TO THE PROJECT. IF AN ANSWER REQUIRES A COST OR TIME EXTENSION TO THE PROJECT, THE SUPERINTENDENT SHALL IMMEDIATELY CONTACT THE OWNER'S PROJECT MANAGER FOR DIRECTION. 5. THE CONTRACTOR, SUPERINTENDENT AND CONTRACTOR'S PROJECT MANAGER WILL ACKNOWLEDGE THAT THE TESTING FIRM'S REPRESENTATIVE IS A PARTICIPATING TEAM MEMBER. THEIR PRIMARY FUNCTION IS TO TEST, OBSERVE, INSPECT AND REPORT. THE TECHNICIAN IS TO COORDINATE DEFICIENCIES WITH THE SUPERINTENDENT FOR TIMELY CORRECTIONS. ALL TESTING REPORTS ARE TO BE DISTRIBUTED PER THE CONTRACT DOCUMENTS WITH COPIES ON SITE FOR INSPECTION BY THE OWNER'S PROJECT MANAGER, CITY OFFICIALS, ETC. ALL DEFICIENT REPORTS WILL HAVE THE CORRECTED REPORTS ATTACHED FOR VERIFICATION. 6. SUPERINTENDENT WILL PROMOTE PRO- ACTIVENESS WITH SUBCONTRACTORS THROUGHOUT THE PROJECT. IDENTIFY CONCERNS, ISSUES, ETC. EARLY AND IN WRITING PRIOR TO IT BECOMING A PROBLEM IN THE FIELD. 7. SUPERINTENDENT AND CONTRACTOR'S PROJECT MANAGER TO CONDUCT A CONTINUAL PUNCH LIST THROUGHOUT THE LIFE OF THE PROJECT; CORRECT AND OR REPLACE DEFICIENCIES AT THE TIME OF DISCOVERY AND NOT WAIT TILL THE END OF THE PROJECT. 8. CONTRACTOR IS RESPONSIBLE TO SCHEDULE THE NATIONAL VENDORS USING FORMAT PROVIDED AND TO MAINTAIN THIS LIVING DOCUMENT AS THE PROJECT PROGRESSES. KEEP IN MIND THE TIME DURATION FOR DELIVERIES OF MATERIALS AND KEEP VENDORS UPDATED AS TO DELIVERIES. 9. CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING AND PROTECTING THE PRODUCTS AND OR MATERIALS FROM OWNER'S VENDORS. 10. THE CONTRACTOR AND ITS ACTIONS ON A PROJECT ARE OFTEN TIMES THE FIRST IMPRESSION A COMMUNITY. HAS TOWARDS THE OWNER. WITH THAT SAID, THE CONTRACTOR AND OTHERS WITHIN THEIR EMPLOY ARE ENCOURAGED TO MAINTAIN A PROFESSIONAL DEMEANOR ON THE PROJECT THROUGHOUT THE COURSE OF CONSTRUCTION. 11. CONTRACTOR SHALL EXERCISE GOOD JUDGEMENT RELATING TO WORKING ADJACENT TO EXISTING HOMES AND OR BUSINESS. CONTROL NOISE, WORK HOURS, DUST CONTROL, EROSION CONTROL MEASURES AS NECESSARY WHILE PERFORMING THEIR DUTIES. CONTACT ADJACENT NEIGHBORS DURING UNUSUAL OPERATIONS OF CONSTRUCTION. 12. SUPERINTENDENT IS REQUIRED TO OBTAIN AND MAINTAIN A HIGH LEVEL OF TRUST AND UNDERSTANDING FROM BUILDING OFFICIALS AND GOVERNING AUTHORITIES DURING CONSTRUCTION AS THIS IS OFTEN TIMES NEEDED IN PULLING CERTIFICATE OF OCCUPANCIES OR TEMPORARY CERTIFICATE OF OCCUPANCY. 13. SUPERINTENDENT IS EXPECTED TO COORDINATE AND COOPERATE WITH TESTING FIRMS TO ASSURE PROJECT COMPLIANCE WHILE MAINTAINING SCHEDULE. I. MERCHANDISE/TRAINING: 1. THE "FINAL PUNCH LIST" AS MENTIONED ABOVE SHOULD BE COMPLETED PRIOR TO WEDNESDAY GO -1. 2. THE SUPERINTENDENT REMAINS ACTIVELY INVOLVED IN THE STORE DURING THIS PHASE AND UNTIL ALL PUNCH LIST ITEMS ARE COMPLETED AND THE STORE HAS ITS FINAL CERTIFICATE OF OCCUPANCY. 3. SUPERINTENDENT IS NOT REQUIRED TO BE ON SITE DURING GO-0 UNLESS THE PUNCHLIST IS NOT COMPLETE OR THE C OF 0 IS NOT IN HAND. PROJECT MEETINGS A. PRECONSTRUCTION MEETING: PRIOR TO THE START OF WORK, CONTRACTOR AND THE OWNER SHALL HAVE A PRECONSTRUCTION MEETING TO DETERMINE THE EXACT SEQUENCING AND PHASING OF CONSTRUCTION. MEETING CALLED BY BEST BUY MOBILE. B. PROGRESS MEETINGS: ATTEND PROGRESS MEETINGS CALLED BY BEST BUY MOBILE THROUGHOUT THE PROGRESS OF WORK. C. SUPERINTENDENT WILL CONDUCT WEEKLY PROJECT MEETINGS WITH ALL TRADES CURRENTLY WORKING ON THE PROJECT AND THOSE WHO WILL BE STARTING WITHIN THE NEXT WEEK. EACH TRADE WILL HAVE A PERSON OF RESPONSIBILITY ATTEND THESE WEEKLY MEETINGS. THESE MEETINGS ARE MANDATORY. CONTRACTOR IS ENCOURAGED TO PENALIZE SUBCONTRACTORS WHO FAIL TO COMPLY. SUPERINTENDENT WILL ASSURE ALL ATTENDEES HAVE VOICED ANY ISSUES AND OR CONCERNS. MINUTES ARE TO BE MAINTAINED AND SENT TO ALL PARTIES IN A TIMELY MANNER. QUALITY CONTROL A. PRECONSTRUCTION: 3. MAKE KNOWN ANY INCONSISTENCIES OF THE PLANS AND OR SPECIFICATIONS; INCONSISTENCIES WITH DETAILS, SITE SPECIFIC ISSUES, REGIONAL DESIGN ISSUES, ETC. PRIOR TO AWARD OF CONTRACT. 4. HOLD SUBCONTRACTORS RESPONSIBLE TO REVIEW THE PLANS AND SPECIFICATIONS FOR SIMILAR INCONSISTENCIES. 5. SELECT SUBCONTRACTORS WITH PROVEN HISTORIES OF MEETING SCHEDULES AND GOOD ORGANIZATIONAL SKILLS. 6. SELECT SUBCONTRACTORS WITH PROVEN HISTORIES OF MEETING AND MAINTAINING QUALITY. 7. UNDERSTAND OWNERS NATIONAL VENDORS TO AVOID DUPLICATION IN BIDS FROM SUBCONTRACTORS. 8. THE SUPERINTENDENT SHALL MAINTAIN ACCURATE AND COMPREHENSIVE DAILY LOGS. ANY TIME AN OWNER'S REPRESENTATIVE ARRIVES TO THE PROJECT, THE SUPERINTENDENT WILL LIST PERTINENT DATA AND NOTIFY THE OWNER'S PROJECT MANAGER IN A TIMELY MANNER. 9. SUPERINTENDENT AND / OR CONTRACTOR'S PROJECT MANAGER WILL PROVIDE A SCHEDULE TO THE OWNER'S PROJECT MANAGER FOR THE PROJECT AND MAINTAIN AN ACCURATE SCHEDULE WEEKLY ON MICROSOFT PROJECT OR EQUAL SCHEDULING SOFTWARE. B. STANDARDS: COMPLY WITH INDUSTRY STANDARDS EXCEPT WHEN MORE RESTRICTIVE TOLERANCES ARE SPECIFIED SPECIFIED REQUIREMENTS INDICATE MORE RIGID STANDARDS OR MORE PRECISE WORKMANSHIP. C. REGULATORY REQUIREMENTS: 1. PERFORM ALL WORK TO MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES, LAWS, REGULATIONS, SAFETY ORDERS, AND DIRECTIVES FROM AUTHORITIES HAVING JURISDICTION OVER THE WORK. 2. ACCESSIBILITY: ALL EQUIPMENT, ACCESSORIES AND WORK SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES WITH RESPECT TO HANDICAP ACCESSIBILITY, AND WITH THE AMERICANS WITH DISABILITIES ACT (ADA). THE MORE RESTRICTIVE CODE SHALL APPLY. D. PERFORM WORK WITH PERSONS QUALIFIED TO PRODUCE WORKMANSHIP OF SPECIFIED QUALITY. E. INSTALL PRODUCTS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONFLICT EXISTS BETWEEN MANUFACTURER'S RECOMMENDATIONS AND THE SPECIFIED REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY. F. EXAMINATION PRIOR TO INSTALLATION: 1. PRIOR TO STARTING WORK, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE. NOTIFY THE OWNER IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. 2. DO NOT BEGIN INSTALLATION UNTIL ALL UNSATISFACTORY CONDITIONS ARE RESOLVED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE CONDITIONS. TEMPORARY FACILITIES AND CONTROLS A. TEMPORARY UTILITIES: PROVIDE TEMPORARY UTILITIES, SERVICES AND CONSTRUCTION AS REQUIRED TO PERFORM THE WORK. COORDINATE ALL TEMPORARY FACILITIES AND CONTROLS WITH BEST BUY MOBILE AND THE BUILDING DEVELOPER/LANDLORD. 1. ELECTRICITY: CONNECT TO EXISTING SERVICE. TAKE MEASURES TO CONSERVE ENERGY. 2. LIGHTING: PERMANENT LIGHTING MAY BE USED DURING CONSTRUCTION. PROVIDE ADDITIONAL TEMPORARY LIGHTING AS REQUIRED. MAINTAIN LIGHTING AND MAKE ROUTINE REPAIRS. 3. HEATING AND VENTILATION: PERMANENT SYSTEM MAY BE USED. MAINTAIN SYSTEM DURING OPERATION. 4. WATER: UTILIZE EXISTING FACILITIES. BEST BUY MOBILE WILL PAY FOR WATER USED. B. CONTROLS: 1. DUST CONTROL: PROVIDED POSITIVE METHODS AND APPLY DUST CONTROL MATERIALS TO MINIMIZE RAISING DUST FROM CONSTRUCTION OPERATIONS, AND PROVIDE POSITIVE MEANS TO PREVENT AIRBORNE DUST FROM DISPERSING INTO THE ATMOSPHERE. 2. WATER CONTROL: COMPLY WITH APPLICABLE JURISDICTIONAL REQUIREMENTS REGARDING WATER USAGE, CONSERVATION, DETENTION, POLLUTION, AND PERMITS. C. MAINTAIN PEDESTRIAN AND VEHICULAR ACCESS TO AND WITHIN SITE TO PROVIDE UNINTERRUPTED ACCESS: 1. TO TEMPORARY CONSTRUCTION FACILITIES, STORAGE AND WORK AREAS. 2. FOR USE BY PERSONS AND EQUIPMENT INVOLVED IN CONSTRUCTION OF PROJECT. 3. FOR USE BY EMERGENCY VEHICLES. 4. TO MINIMIZE IMPACT ON ADJACENT OPERATIONS. D. FIRE SAFETY: COMPLY WITH APPLICABLE PROVISIONS OF UFC ARTICLE 87 FOR FIRE SAFETY DURING DEMOLITION AND CONSTRUCTION OPERATIONS. E. TEMPORARY CONSTRUCTION: 1. OBTAIN APPROVAL FROM BEST BUY MOBILE FOR ALL MODIFICATIONS TO EXISTING SYSTEMS OR FACILITIES NOT INDICATED. 2. REMOVE TEMPORARY SYSTEMS OR FACILITIES WHEN USE IS NO LONGER REQUIRED. CLEAN AND REPAIR DAMAGE CAUSED BY INSTALLATION OR USE OF TEMPORARY SYSTEMS OR FACILITIES. F. CONSTRUCTION CLEANING: 1. CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH. PERIODICALLY DISPOSE OF OFF -SITE. 2. MAINTAIN AREAS FREE OF DUST AND OTHER CONTAMINANTS DURING FINISHING OPERATIONS. PRODUCT REQUIREMENTS A. DELIVERY, STORAGE, AND HANDLING: 1. TRANSPORT AND HANDLE PRODUCTS BY METHODS TO AVOID PRODUCT DAMAGE. 2. MANUFACTURED PRODUCTS SHALL REMAIN IN MANUFACTURER'S CONTAINERS OR PACKAGING, UNTIL READY FOR INSTALLATION. 3. UNLESS SPECIFIED OTHERWISE, STORE MANUFACTURED PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. PRODUCT OPTIONS AND SUBSTITUTIONS: 1. FURNISH PRODUCTS SPECIFIED, EXCEPT WHERE "OR APPROVED" IS USED, SUBSTITUTE PRODUCTS MAY BE SUBMITTED TO THE OWNER'S CONSTRUCTION PROJECT MANAGER. 2. SUBSTITUTIONS WILL BE CONSIDERED ONLY FOR THE FOLLOWING REASONS: a. A PRODUCT BECOMES UNAVAILABLE DUE TO NO FAULT OF THE CONTRACTOR. b. SUBSEQUENT INFORMATION OR CHANGES INDICATE THAT THE SPECIFIED PRODUCT WILL NOT PERFORM AS INTENDED. c. A SUBSTITUTE PRODUCT WILL BE IN THE OWNER'S BEST INTEREST. 3. DOCUMENT EACH SUBSTITUTION REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. 4. A SUBSTITUTION REQUEST CONSTITUTES A REPRESENTATION THAT CONTRACTOR a. HAS INVESTIGATED PROPOSED PRODUCT AND HAS DETERMINED THAT IT MEETS OR EXCEEDS, IN ALL RESPECTS, THE SPECIFIED PRODUCT. b. SHALL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED PRODUCT. c. WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES WHICH MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS. d. HAS DETERMINED NO ADDITIONAL COST WILL BE INCURRED TO BBM BECAUSE OF SUBSTITUTION. e. HAS DETERMINED THE SCHEDULE WILL NOT BE IMPACTED BECAUSE OF SUBSTITUTION. 5. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE INDICATED OR IMPLIED ON SHOP DRAWINGS OR PRODUCT DATE SUBMITTALS. 6. BEST BUY MOBILE WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN A REASONABLE TIME. PATCHING AND REPAIR A. REPAIR EXISTING SURFACES AND CONSTRUCTION AS NECESSARY TO MAKE WORK COMPLETE, WITH ALL COMPONENTS MATCHING AND CONSISTENT. B. PROVIDE A SMOOTH, EVEN, AND INVISIBLE TRANSITION TO NEW CONSTRUCTION. WHEN FINISHED SURFACES ARE CUT SO THAT AN INVISIBLE TRANSITION WITH NEW WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG THE NEAREST BREAK LINE, JOINT, OR CORNER. CLOSE -OUT PROCEDURES A. FINAL CLEANING: 1. THOROUGHLY CLEAN ALL SURFACES PRIOR TO TURN OVER. 2. REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH, AND CONSTRUCTION FACILITIES FROM THE SITE. 3. G.C. TO COORDINATE DUMPSTERS. 4. TOUCH UP /CLEAN TO BE COMPLETE PRIOR TO G.O. DATE MINUS 1 DAY. B. GRAND OPENING: 1. THE ELECTRICAL, PLUMBING AND HVAC SUBCONTRACTOR IS TO BE PUT ON NOTICE TO RESPOND IMMEDIATELY (WITHIN 30 MINUTES) IF CALLED WITH ANY PROBLEMS THAT MAY ARISE DURING OWNER'S GRAND OPENING. C. CLOSE -OUT PROCEDURES: 1. COMPLY WITH PROCEDURES STATED IN GENERAL CONDITIONS OF THE CONTRACT FOR SUBSTANTIAL AND FINAL COMPLETION. 2. SUBMIT ALL CERTIFICATES OF APPROVAL ISSUED BY THE GOVERNING AUTHORITIES TO BEST BUY MOBILE, INCLUDING, WITHOUT LIMITATION, THE FOLLOWING: a. CERTIFICATE OF OCCUPANCY. 3. PRIOR TO FINAL PAYMENT, SUBMIT THE FOLLOWING AFFIDAVITS TO BEST BUY MOBILE USING THE FORMS LISTED BELOW: a. CONTRACTOR'S AFFIDAVIT OF PAYMENT OF DEBTS AND CLAIMS AIA DOCUMENT G706. b. CONSENT OF SURETY TO FINAL PAYMENT AIA DOCUMENT G707. c. CONTRACTOR'S LIEN RELEASE, AND LIEN RELEASES FROM EACH SUBCONTRACTOR; CONTRACTOR'S AFFIDAVIT OF RELEASE OF LIENS AIA DOCUMENT G706A 4. SUBMIT FINAL APPLICATION FOR PAYMENT TO BEST BUY MOBILE IDENTIFYING TOTAL ADJUSTED CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE. 5. ALL CLOSEOUT DOCUMENTS ARE TO BE SUBMITTED WITHIN 30 DAYS OF G.O. 6. THE GENERAL CONTRACTOR DURING THIS PHASE SHALL HAVE ALL "AS -BUILT DRAWINGS" COMPLETED WITHIN 30 DAYS AFTER STORE OPENING. FINAL RETAINAGE WILL NOT BE RELEASED TO THE CONTRACTOR UNTIL SUCH TIME THAT THE 'AS -BUILT DRAWINGS AND THE FULLY COMPLETED 'CLOSE OUT DOCUMENTS' ARE RECEIVED, REVIEWED AND APPROVED BY THE OWNER'S PROJECT MANAGER. ONE COPY IS RETAINED BY THE STORE, PLACED WITHIN A PVC PIPE WITH CAP MOUNTED IN THE ELECTRICAL ROOM, LABELED AS SUCH WHILE THE OTHER SET, ALONG WITH THE SECOND "FINAL CLOSE OUT DOCUMENTS" SHALL BE SENT TO THE OWNER'S PROJECT MANAGER. 7. THE CONTRACTOR SHALL HAVE FINAL COSTS IN HAND AND READY TO SUBMIT TO OWNER FOR THEIR FINAL PAY APPLICATION PER THE CONTRACT DOCUMENTS NO LATER THAN 30 DAYS AFTER GRAND OPENING. C. PROJECT RECORD DOCUMENTS: 1. MAINTAIN A COMPLETE SET OF FULL SIZE RECORD DRAWINGS WHICH CLEARLY AND NEATLY INDICATE EXACT INSTALLED LOCATIONS OF ITEMS WHICH WILL BE CONCEALED IN THE WORK SUCH AS CONDUIT, PIPING, DUCTS, REINFORCING, MECHANICAL AND ELECTRICAL EQUIPMENT, AND SIMILAR ITEMS. SHOW ALL CHANGES FROM THE CONTRACT DOCUMENTS, AND ALL UNCOVERED EXISTING CONDITIONS WHICH WILL BE SUBSEQUENTLY CONCEALED. 2. RECORD DRAWINGS SHALL BE USED FOR NO OTHER PURPOSE AND SHALL BE STORED SEPARATELY FROM THOSE USED IN CONSTRUCTION. 3. DOCUMENTS SHALL BE IN SAME FORMAT AS THE CONSTRUCTION DOCUMENTS. 4. KEEP DOCUMENTS CURRENT; DO NOT PERMANENTLY CONCEAL ANY WORK UNTIL REQUIRED INFORMATION HAS BEEN RECORDED. 5. AT CONTRACT CLOSE -OUT, SUBMIT DOCUMENTS WITH TRANSMITTAL LETTER CONTAINING DATE, PROJECT TITLE, CONTRACTOR'S NAME AND ADDRESS, LIST OF DOCUMENTS AND SIGNATURE OF CONTRACTOR TO ARCHITECT. D. SUBMITTALS: IN ADDITION TO SUBMITTALS REQUIRED BY THE CONDITIONS OF THE CONTRACT, FURNISH SUBMITTALS REQUIRED BY GOVERNING AUTHORITIES, AND SUBMIT A FINAL STATEMENT OF ACCOUNTING GIVING TOTAL ADJUSTED CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE. E. SUBMIT THE INFORMATION LISTED IN F, G AND H BELOW TO THE FOLLOWING ADDRESS: BBE PROPERTIES PROPERTY DEVELOPMENT NICOLE ALLEN- B3-363 7601 PENN AVENUE SOUTH RICHFIELD, MN 55423 PH: 612 - 291 -7511 F. OPERATION AND MAINTENANCE DATA: 1. SUBMIT COMPLETE DATA FOR EACH PIECE OF NEW EQUIPMENT AND COMPONENT USED IN THE WORK. 2. SUBMIT OPERATION AND MAINTENANCE DATA FOR MECHANICAL AND ELECTRICAL SYSTEMS. 3. ARRANGE IN A BINDER WITH A SECTION FOR EACH SYSTEM. 4. SUBMIT OPERATION AND MAINTENANCE DATA TO BEST BUY MOBILE CONSTRUCTION PROJECT MANAGER. G. WARRANTIES, GUARANTEES AND BONDS: 1. SUBMIT ALL MANUFACTURER WARRANTIES TO BEST BUY MOBILE WITH EXCEPTION TO OWNER SUPPLIED FURNISHINGS. 2. FURNISH WRITTEN GUARANTEE FROM EACH SUBCONTRACTOR PERFORMING WORK COVERED BY THE ADDITIONAL GUARANTEE REQUIREMENTS SPECIFIED IN THE TECHNICAL SECTIONS. UNLESS SPECIFIED OR APPROVED OTHERWISE, THE GUARANTEE SHALL COMMENCE ON THE DATE OF SUBSTANTIAL COMPLETION. 3. EACH GUARANTEE SHALL BE SIGNED, AND SHALL STATE THAT THE WORK UNDER GUARANTEE WAS INSTALLED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, AND THAT THE WORK WILL BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL FOR THE PERIOD OF 1 YEAR AFTER G.O., AND THAT ALL DEFECTS WILL BE PROMPTLY REPAIRED WITHOUT ADDITIONAL COST TO BEST BUY MOBILE. H. SPARE PARTS AND MAINTENANCE MATERIALS: 1. FURNISH PRODUCTS, SPARE PARTS, AND MAINTENANCE MATERIALS IN QUANTITIES SPECIFIED IN EACH SECTION, IN ADDITION TO THAT USED FOR CONSTRUCTION OF WORK. 2. COORDINATE WITH BEST BUY MOBILE STORE MANAGER; DELIVER TO PROJECT SITE AND OBTAIN RECEIPT PRIOR TO FINAL PAYMENT. 3. UNLESS SPECIFIED OTHERWISE, DELIVER MATERIALS IN MANUFACTURER'S ORIGINAL FACTORY CARTONS OR CONTAINERS. 4. MATERIALS SHALL BE CLEARLY LABELED, AND SHALL INCLUDE DESIGNATIONS USED IN THE CONTRACT DOCUMENTS. DMSION 02 - SITEWORK 02 411 SELECTIVE DEMOLITION A. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE THE WORK . WHERE DEMOLITION EXCEEDS THAT INDICATED, VERIFY SUCH DEMOLITION WITH THE OWNER PRIOR TO PROCEEDING. B. PROTECT EXISTING STRUCTURAL MEMBERS. CONTACT THE OWNER PRIOR TO MODIFYING STRUCTURAL MEMBERS BEYOND THE EXTENT INDICATED. CEASE OPERATIONS AND NOTIFY THE OWNER IMMEDIATELY IF CONTINUED DEMOLITION OPERATIONS MIGHT ENDANGER THE EXISTING STRUCTURE. C. DURING DEMOLITION OPERATIONS, NOTIFY THE OWNER OF ALL CONDITIONS WHICH DIFFER SUBSTANTIALLY FROM THOSE INDICATED, SPECIFIED, OR EXPECTED. NOTIFY THE OWNER IF PREVIOUSLY UNKNOWN OPERATIONAL, OR POTENTIALLY OPERATIONAL ELEMENTS, ARE UNCOVERED DURING DEMOLITION OPERATIONS. PERFORM NO DEMOLITION IN SUCH AREAS, UNLESS APPROVED BY THE OWNER. D. PROVIDE TEMPORARY SHORING AS REQUIRED TO SUPPORT EXISTING CONSTRUCTION AGAINST MOVEMENT OR OVERLOAD DURING DEMOLITION OPERATIONS, UNTIL PERMANENT SUPPORTS ARE IN PLACE. E. EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF MATERIALS BEING DEMOLISHED AND IMMEDIATELY REMOVE FROM SITE. DO NOT OVERLOAD EXISTING CONSTRUCTION TO REMAIN WITH DEMOLISHED MATERIALS. F. CAREFULLY REMOVE, STORE AND PROTECT ALL MATERIALS AND COMPONENTS TO BE REUSED. G. WHERE POSSIBLE WITHOUT DAMAGE, REMOVE, STORE AND PROTECT EXISTING MATERIALS AND COMPONENTS NOT NOTED FOR REMOVAL, WHICH IF REMOVED, WOULD FACILITATE THE NEW CONSTRUCTION AND RECONDITIONING. H. CAREFULLY REMOVE, PROTECT, AND TURN OVER AS DIRECTED, MATERIALS AND COMPONENTS CLAIMED BY BEST BUY MOBILE OR THE BUILDING OWNER FOR SALVAGE. PRIOR TO DEMOLITION, CONTACT BEST BUY MOBILE TO DETERMINE WHICH ITEMS WILL BE CLAIMED. I. WHERE CUT EDGES OF THE EXISTING CONSTRUCTION WILL BE VISIBLE IN THE COMPLETED WORK, CUT IN UNIFORM STRAIGHT LINES. CONCRETE AND MASONRY SHALL BE SAW CUT OR CORE DRILLED. J. REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO ADDITIONAL COST TO BEST BUY MOBILE. DIVISION 03 - CONCRETE 03 000 SELF LEVELING UNDERLAYMENTITOPPING A. GENERAL: 1. COMPLY W/ MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION & INSTALLATION OF MATERIALS. 2. DO NOT INSTALL UNDERLAYMENT UNTIL FLOOR PENETRATIONS & PERIPHERAL WORK ARE COMPLETE. 3. CEMENTITIOUS UNDERLAYMENT a. ARDEX ENGINEERED CEMENTS, INC OR EQUAL. B. PREPARATION / EXECUTION: 1. PREPARATION a. VERIFY THAT SUBSTRATE SURFACES ARE CLEAN, DRY, UNFROZEN, DO NOT CONTAIN PETROLEUM BI- PRODUCTS, OR OTHER COMPOUNDS DETRIMENTAL TO UNDERLAYMENT MATERIAL BOND TO SUBSTRATE. b. REMOVE SUBSTRATE SURFACE IRREGULARITIES. c. FILL VOIDS AND DECK JOINTS WITH FILLER. FINISH SMOOTH. d. VACUUM CLEAN SURFACES. e. PRIME SUBSTRATE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. C. EXECUTION 1. INSTALL UNDERLAYMENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR CURING, FIELD TESTING AND PROTECTION OF FINISHED WORK. 03 330 CAST -IN -PLACE CONCRETE A. EXPOSED CONCRETE FINISH 1. APPLY CONCRETE HARDENER AND SLIP - RESISTANT COATING /SEALER ON FLOOR SURFACES AS SCHEDULED. APPLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 2. CLEAN FLOORS PRIOR TO APPLICATION OF HARDENER. a. NOX -CRETE BIO- CLEAN. USED TO CLEAN SILCOSEAL RESIDUE OFF OF SLAB. DILUTE 1 PART BIO -CLEAN WITH 3 PARTS WATER, APPLY SOLUTION AT 200 SF /GAL. AND SCRUB FLOOR USING A WALK- BEHIND OR RIDING -TYPE FLOOR MACHINE EQUIPPED WITH NYLON SCRUB BRUSHES. RINSE SLAB WITH CLEAN WATER AND USE SQUEEGEE TO DRY. 3. IF OTHER MEMBRANE CURING AGENT WAS USED, REMOVE AS RECOMMENDED BY MANUFACTURER. 4. TEST SURFACE TO CONFIRM CURING AGENT WAS REMOVED. 5. APPLY DURO -NOX, LINE STRIP, AND ONE COAT DURO- POLISH IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION. DIVISION 04- MASONRY NOT USED DMSION 5- METALS 05 400 METAL FRAMING LIGHT GAUGE (COLD- FORMED) METAL FRAMING A. SUMMARY: INTERIOR LIGHT GAUGE SUPPORT FRAMING. B. SYSTEM DESCRIPTION 1. STRUCTURAL DESIGN: a. SELECT FRAMING SYSTEMS, GAUGES, SUPPORTS, BRACING, AND CONNECTIONS AS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS SPECIFIED, AND NOTED ON THE DRAWINGS. b. PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED, UNLESS APPROVED OTHERWISE. PROVIDE THICKER GAUGES AND INCREASED STUD SPACING AS NECESSARY TO MEET THE DESIGN REQUIREMENTS. 2. DESIGN LOADS: a. INTERIOR CEILING ASSEMBLIES: PROVIDE FRAMING COMPONENTS AS INDICATED ON THE DRAWINGS. b. INTERIOR PARTITIONS: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LATERAL LOAD. c. SEISMIC LOADS: CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, SEISMIC ZONE. 3. DEFLECTION REQUIREMENTS: MAXIMUM OF 1/240 THE SPAN. C. CODE REQUIREMENTS: 1. PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED AND SPECIFIED. ASSEMBLIES SHALL HAVE BEEN TESTED IN ACCORDANCE WITH ASTM E119, AND SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. COORDINATE INSTALLATION OF OTHER MATERIALS WHICH ARE A PART OF EACH ASSEMBLY. 2. FIRE RATING REQUIREMENTS TAKE PRECEDENCE OVER THE CONSTRUCTION REQUIREMENTS INDICATED. IN THE EVENT OF CONFLICT, NOTIFY THE OWNER, AND DO NOT BEGIN CONSTRUCTION IN THE AREA OF CONFLICT UNTIL THE CONFLICT HAS BEEN RESOLVED. D. MATERIALS AND COMPONENTS: 1. LIGHT GAUGE METAL FRAMING: ASTM C645; GALVANIZED; PROVIDE "C" SHAPED STUDS, U SHAPED RUNNERS, HAT AND "Z" SHAPED FURRING CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED ON THE DRAWINGS, AND REQUIRED IN THE STANDARDS REFERENCED. MINIMUM 18 GAUGE, EXCEPT PROVIDE THICKER GAUGES AS REQUIRED TO MEET DEFLECTION REQUIREMENTS OR AS INDICATED ON THE DRAWINGS. 2. COLD ROLLED CHANNELS: RUST INHIBITIVE PAINT COATING; SIZES IN ACCORDANCE WITH ASTM C754. 3. SCREWS: SELF TAPPING; LOW PROFILE HEAD. 4. FIRE RATED TRACK: AS SPECIFIED IN SECTION 07840. 5. PARTITION HEAD COMPENSATING CHANNEL: DESIGN FOR MINIMUM + OR -1/2 INCH DEFLECTION. PROFILES AS INDICATED; ONE OF THE FOLLOWING. a. 18 GAUGE DEEP LEG TRACK; 2 INCH LEGS. b. SLIP TRACK SYSTEMS INC. (ANAHEIM, CA; 714 -761 -1921) "SLP -TRK." 6. OTHER FRAMING MATERIALS: FURNISH IN ACCORDANCE WITH ASTM C754. E. PARTITION FRAMING: 1. RUNNERS: a. SECURE RUNNERS WITH FASTENERS AT MAXIMUM 12 INCHES OC. b. AT CONCRETE FLOORS, USE POWER DRIVEN FASTENERS OR DRILLED IN CONCRETE ANCHORS. c. WHERE INDICATED, ATTACH TOP TRACK TO ACOUSTICAL CEILING GRID WITH TWO STAGGERED #12 -14 SCREWS AT 24 INCHES ON CENTER. PROVIDE SPACER STRIP BETWEEN RUNNER AND CEILING SUSPENSION SYSTEMS TO ALLOW REGULAR OR REVEAL EDGE ACOUSTICAL PANELS TO CLEAR PARTITION. USE MINIMUM 18 GAUGE TOP TRACK. d. TOP RUNNER: USE PROPRIETARY COMPENSATING CHANNEL OR DEEP LEG TRACK AT CONTRACTOR'S OPTION, AS NECESSARY TO ACCOMMODATE BUILDING DEFLECTION. e. UNLESS APPROVED OTHERWISE, AT FIRE RATED PARTITION ASSEMBLIES, USE FIRE RATED TRACKS. INSTALL FIRE RATED TRACKS IN ACCORDANCE WITH THE FIRE RATED ASSEMBLY REQUIREMENTS. f. ALIGN TO TOLERANCES SPECIFIED. 2. UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 16 INCHES OC, AND NOT MORE THAN 2 INCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF OPENINGS, AND AT CORNERS. 3. FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE STUDS AT SPACING OF WALL STUDS. 4. BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID. PROVIDE DIAGONAL STUD BRACING AT 4 FT ON CENTER AT ALL FRAMING WHICH DOES NOT EXTEND TO STRUCTURE. 5. INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO CEILING TRACK AT THE JAMB OF EACH DOOR FRAME AND CASED OPENING. STUDS SHALL BE THE SAME GAUGE AS THE ADJACENT STUDS, BUT NO LESS THAN 18 GAUGE. PROVIDE DIAGONAL STEEL STUD BRACING TO STRUCTURE AT EACH JAMB AT PARTITIONS WHICH DO NOT EXTEND TO STRUCTURE. 6. COORDINATE ERECTION OF STUDS WITH INSTALLATION OF SERVICE UTILITIES. ALIGN STUD WEB OPENINGS. 7. COORDINATE ERECTION OF STUD SYSTEM WITH REQUIREMENTS OF DOOR AND WINDOW FRAMES, FIRE EXTINGUISHER CABINETS, ACCESS DOORS, AND OTHER CONSTRUCTION WITHIN MOUNTED PARTITION CONSTRUCTION. 8. COORDINATE THE INSTALLATION OF FRAMING WITH THE GYPSUM BOARD INSTALLER TO ENSURE SUPPORT AT ALL BOARD EDGES. PROVIDE FRAMING WITH THE GYPSUM BOARD INSTALLER TO ENSURE SUPPORT AT ALL BOARD EDGES. PROVIDE FRAMING IMMEDIATELY EITHER SIDE OF EXPANSION JOINTS. 9. STUD SPLICING NOT PERMISSIBLE. 10. AT NON -LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, CUT STUDS 1/2 INCH SHORT FROM FULL HEIGHT. DO NOT RIGIDLY CONNECT STUD TO TOP RUNNER. 11. STUD BRIDGING: a. AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS ATA MAXIMUM OF 5' -0" ON CENTER FOR THE FULL HEIGHT OF THE PARTITION. b. INTERIOR FULL HEIGHTS PARTITIONS (STUDS EXTENDING FROM THE FLOOR TO THE STRUCTURE ABOVE) WITH RIGID FACING MATERIAL STOPPING 3' -0" OR MORE BELOW TOP OF STUDS - PROVIDE ONE ROW 3/4" BRIDGING CHANNEL HORIZONTALLY AT TERMINATION OF GYPSUM BOARD MATERIAL, AND ONE ADDITIONAL ROW FOR EACH 5' -0" OF EXPOSED STUDS. c. INSTALL STUD BRIDGING CHANNEL IN LONG LENGTHS, WIRE TYING AND LAPPING THE JOINTS A MINIMUM OF 12." ATTACH BRIDGING CHANNEL TO EACH STUD AS SHOWN IN MANUFACTURER'S PRINTED INSTRUCTIONS. F. CEILING AND SOFFIT FRAMING: 1. COORDINATE LOCATIONS OF HANGERS AND SUPPORTS WITH THE WORK OF OTHER SECTIONS. 2. PROVIDE CEILING AND SOFFIT FRAMING AS INDICATED. WHERE NOT INDICATED PROVIDE STUD AND RUNNER FRAMING. 3. STUD AND RUNNER FRAMING: a. SECURE RUNNERS TO STRUCTURE ABOVE FASTENERS AT A MAXIMUM OF 12 INCHES ON CENTER. SIZE FASTENER AND USE REINFORCEMENTS AS NECESSARY TO SUPPORT THE DEAD LOADS APPLIED. b. SCREW FASTEN FRAMING AT EACH FLANGE JOINT. c. SPACE STUDS AT 16 INCHES ON CENTER OF HORIZONTAL LOCATIONS. d. SELECT MEMBERS TO MEET THE STRUCTURAL REQUIREMENTS SPECIFIED. 4. FORM OPENINGS IN CEILINGS AND FRAME OPENINGS FOR RECESSED LIGHT FIXTURES, AIR DIFFUSERS, ACCESS DOORS, HATCHES, ETC. 5. INSTALL SUPPLEMENTARY HANGER WIRES FOR SUPPORT OF CEILING MOUNTED EQUIPMENT. G. BACKING: 1. PROVIDE METAL BACKING/BLOCKING, AS SPECIFIED ON DRAWINGS. 2. COORDINATE ALL REQUIRED BLOCKING FOR FURNITURE, SHELVING, CABINETS, PROJECTORS, WALL STOPS, ETC., WITH THE APPROPRIATE VENDOR. H. INSTALLATION TOLERANCES: 1. INSTALL MEMBERS TO PROVIDE SURFACE PLANE WITH MAXIMUM VARIATION OF 1/8 INCH IN 10 FEET IN ANY DIRECTION. 2. LOCATE ASSEMBLIES WITHIN 1/4 INCH OF REQUIRED LOCATIONS. 05 500 MISCELLANEOUS METAL FABRICATIONS A. B. C. D. SUMMARY: STEEL FABRICATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS AND NOT SPECIFIED IN OTHER SECTIONS. MATERIALS: 1. STEEL PLATE, BARS, SHAPES: ASTM A36. 2. TUBES: ASTM A500 GRADE B 3. PIPE: ASTM A53, SEAMLESS, TYPE S, PLAIN END; SCHEDULE 40 UNLESS INDICATED OTHERWISE. 4. BOLTS AND NUTS: ASTM A307. 5. UNISTRUT: UNISTRUT CORPORATION (WAYNE, MI) OR APPROVED EQUAL. FURNISH MANUFACTURER'S STANDARD COMPONENTS CORRESPONDING TO "P" NUMBERS INDICATED ON THE DRAWING. INCLUDE MECHANICAL FASTENERS AND ACCESSORIES PER MANUFACTURES RECOMMENDATIONS 6. 1/2" OR 3/4" METAL REVEAL 7. BREAK METAL: a. MANUFACTURER'S RECOMMENDATIONS. PREFERRED VENDOR: AMERICAN PRODUCTS, INC. (API) 813- 925 -0144 - OFFICE 813 - 925 -1414 - FAX 1) CLEAR ANODIZED ALUMINUM 2) .063 INCHES THICK b. SUBSTITUTIONS: ACCEPTABLE , IF MEETING OR EXCEEDING PRODUCT REQUIREMENTS FROM API. METAL FABRICATION REQUIREMENTS: FABRICATE AS FOLLOWS, UNLESS SPECIFIED OR INDICATED OTHERWISE. 1. VERIFY ALL DIMENSIONS AND FABRICATE TO DETAIL WITH ACCURATE SIZES AND SHAPES, STRAIGHT LINES, SMOOTH CURVES, AND SHARP ANGLES. 2. WELDS SHALL HAVE SUFFICIENT STRENGTH TO WITHSTAND THE LOADS APPLIED. INSTALLATION: 1. INSTALL METAL FABRICATIONS IN ACCURATE LOCATIONS SHOWN. UNLESS INDICATED OTHERWISE, FABRICATIONS SHALL BE INSTALLED PLUMB AND LEVEL. 2. PROVIDE ALL ANCHORAGE DEVICES AS INDICATED AND REQUIRED FOR A SECURE INSTALLATION. 3. UTILIZE ADHESIVE AS RECOMMENDED BY MANUFACTURER TO PREVENT "OIL- CANNING ". 4. REVEALS TO MATCH COLOR OF ALUMINUM. DIVISION 06 - WOODS AND PLASTICS 06 000 FIBERGLASS REINFORCED PLASTIC PANELS (FRP) A. B. C. CONTRACTOR TO PROVIDE PANELS, MOLDINGS, ADHESIVE, AND JOINT SEALERS. MANUFACTURER: MARLITE (330) 343 -6621, KEMLITE (800) 435 -0080, OR EQUAL. COLOR: WHITE. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE MANUFACTURER. D. INSTALL PANELS AS INDICATED IN DRAWINGS AND PER MANUFACTURER'S INSTRUCTIONS. 06 100 WOOD BLOCKING AND CURBING A. PROVIDE WOOD FURRING, BLOCKING, GROUNDS AND IN -WALL BLOCKING FOR SUPPORT OF FIXTURES, EQUIPMENT, CASEWORK, HARDWARE, TRIM AND SIMILAR WORK. 1. USE FIRE RETARDANT TREATED (F.R.T.) WOOD ELSEWHERE AS REQUIRED BY STATE & LOCAL CODES, INCLUDING ANY WOOD STUDS, BLOCKING, FURRING, PLYWOOD, TRIM, AND GROUNDS. NEW LUMBER TO BEAR GRADE & TREATMENT OF ASSOC. UNDER WHICH IT WAS PRODUCED. B. PERFORMANCE REQUIREMENTS: 1. MOISTURE CONTENT: AFTER TREATMENT, THE MAXIMUM MOISTURE CONTENT OF WOOD MATERIALS SHALL NOT EXCEED THE FOLLOWING: a. LUMBER, 2 INCHES AND LESS IN THICKNESS: 19 PERCENT. b. PLYWOOD: 15 PERCENT. C. D. 2. FLAME SPREAD: FIRE RETARDANT TREATED MATERIALS TO HAVE FLAME SPREAD RATING OF 25 OR LESS IN A 30 MINUTE TEST WITH NO EVIDENCE OF SIGNIFICANT PROGRESSIVE COMBUSTION, ASTM E 84, ADDITIONALLY, FLAME FRONT NOT TO PROGRESS MORE THAN 101/2 FEET BEYOND CENTER LINE OF BURNER AT ANY TIME. 3. SMOKE DEVELOPED: INTERIOR FINISH & TRIM MATERIALS, WHERE SPECIFIED, TO HAVE FIRE RETARDANT TREATMENT CONFORMING TO ABOVE REQUIREMENTS FOR "FLAME SPREAD" PLUS SMOKE DEVELOPED RATING OF 25 OR LESS, ASTM E 84. EACH PIECE OF WOOD SHALL BEAR THE UL LABEL INDICATING TREATMENT (U.L. RATING OF RF -3). 4. CERTIFICATES: FURNISH AFFIDAVIT IF REQUIRED BY CODE OFFICIAL STATING THAT MATERIALS HAVE BEEN TREATED IN ACCORDANCE W/ SPECIFICATIONS & THAT MOISTURE CONTENT, AFTER TREATMENT, DOES NOT EXCEED SPECIFIED LIMITS; INCLUDE CHEMICAL USED AND RETENTION OBTAINED FOR PRESSURE TREATED MATERIAL. INCLUDE THE "QUALITY MARK" OF ASSOCIATION HAVING JURISDICTION OVER THE TREATMENT. 5. DELIVER TREATED MATERIALS BUNDLED AND MARKED TO IDENTIFY TREATMENT. 6. STORE TREATED MATERIALS FOR EASY IDENTIFICATION AND PROTECT FROM MOISTURE; PROVIDE WELL - VENTILATED DRY STORAGE. 7. HANDLE TREATED MATERIALS IN ACCORDANCE W/ AWPA STANDARDS. IN ADDITION TO MATERIAL USED IN TREATMENT, FURNISH ADDITIONAL MATERIAL FOR FIELD TREATMENT OF CUTS. 8. FIELD CUTS AND HOLES: FIELD -TREAT IN ACCORDANCE WITH AWPA M-4. SET MEMBERS LEVEL AND PLUMB, IN CORRECT POSITION. NEW FRAMING AT STOREFRONT AND ABOVE CEILING SHALL BE NON- COMBUSTIBLE 06 400 SLOTTED DISPLAY PANELING A. SAS METAL SLATWALL WITH GROOVES FOR DISPLAY. REFERENCE FINISH SCHEDULE IN DRAWINGS. B. STORE PANELS IN COOL DRY ENVIRONMENT. C. ALLOW PANELS TO ACCLIMATIZE TO ROOM CONDITIONS FOR AT LEAST 48 HOURS PRIOR TO INSTALLATION. D. ATTACH TO WALL PER MANUFACTURERS INSTRUCTION AND PER LOCATION AS SHOW ON DRAWINGS. DIVISION 07 - THERMAL AND MOISTURE PROTECTION 07 840 FIRESTOPPING A. SUMMARY: FIRESTOPPING MATERIAL FOR PENETRATIONS IN FIRE -RATED CONSTRUCTION. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2012 City of Tukwila BUILDING DIVISION B. SYSTEM DESCRIPTION: 1. EACH FIRESTOPPING SYSTEM SHALL BE SELECTED TO MAINTAIN FIRE RATING OF THE ASSEMBLY IN WHICH IT IS USED. 2. FIRESTOPPING SYSTEMS SHALL BE RESILIENT AS NECESSARY TO ACCOMMODATE DIFFERENTIAL MOVEMENT BETWEEN ASSEMBLIES. C. QUALITY ASSURANCE: 1. PRIOR TO INSTALLATION OF FIRE STOPPING SYSTEMS OBTAIN APPROVAL FROM THE JURISDICTIONAL CODE AUTHORITIES FOR THE FIRE STOPPING SYSTEMS AND APPLICATIONS PROPOSED. NOTIFY THE OWNER IF APPROVAL CANNOT BE OBTAINED. 2. FIRESTOPPING: TESTED IN ACCORDANCE WITH ASTM E119, ASTM E814, OR UL 1479 TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. PROVIDE F RATED ASSEMBLIES, EXCEPT WHERE T RATED ASSEMBLIES ARE REQUIRED BY THE CODE AUTHORITY. 3. FIRESTOPPING SYSTEMS SHALL BE UL LISTED ASSEMBLIES. D. PRODUCTS: 1. FIRESTOPPING SYSTEMS: SYSTEMS MEETING THE REQUIREMENTS SPECIFIED AND SUITABLE FOR THE CONDITIONS INDICATED. E. INSTALLATION: f�E(;tivtu. 1. PROVIDE FIRESTOPPING AT MECHANICAL, ELECTRICAL, AND PLUMBING PENETRATIONS THROUGH FIRE RATED FLOORS, WALL �ITY OF TUKlWILA. AND CEILINGS, AND OTHER LOCATIONS AS INDICATED ON THE DRAWINGS. 2. INSTALL FIRESTOPPING IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND AS NECESSARY TO MEET THE MAY 2012 SPECIFIED FIRE RATING REQUIREMENTS. PERMIT CENTER w C-) Li z z W a. I- 0 0 F- z a N CV N 0 0 DATE ISSUED 0 z W rz r-0 r 0N.LP') 0M��N _Iw,r I • s - F- c0 2 0 D 1� M • z..- E Z w�c`ic�o® W V) V . (n p W N Q 2ZW I- z Q O • c7)zo m ZZ cLL W SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF CONCEPT: 1.0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: # ## O 0 PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: NO SCALE SPECIFICATIONS A -11 07 920 JOINT SEALANTS A. SEALANTS: 1. TYPE A - ASTM C834; TREMCO "ACRYLIC LATEX CAULK", PECORA "AC -20 ", SONNEBORN "SONOLAC" OR APPROVED EQUAL; STANDARD COLORS TO MATCH ADJACENT CONSTRUCTION. 2. COLORS: a. COLORS SHALL BE SELECTED FROM MANUFACTURERS COMPLETE LINE OF PRE - FORMULATED COLORS. b. SEALANT COLOR SHALL MATCH ADJACENT MATERIAL, UNLESS OTHERWISE INDICATED OR SPECIFIED. B. ACCESSORY MATERIALS: 1. JOINT CLEANER: NON- CORROSIVE AND NON - STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS. 2. JOINT FILLER: CLOSED CELL POLYETHYLENE FOAM; ROUND PROFILE; THICKNESS: 130% OF JOINT WIDTH. 3. BOND BREAKER: PRESSURE - SENSITIVE TAPE RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. C. PREPARATION: 1. CLEAN AND PREPARE JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE ANY LOOSE MATERIALS AND OTHER FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT. 2. APPLY MASKING TIGHTLY AROUND JOINTS TO PROTECT ADJACENT SURFACES FROM EXCESS SEALANT. 3. AT WIDE JOINTS, PLACE BACKING MATERIALS TO ACHIEVE PROPER SEALANT WIDTH /DEPTH RATIOS. USE BOND BREAKER WHERE THERE IS INSUFFICIENT DEPTH FOR BACKING MATERIALS. D. INSTALLATION: 1. PERFORM WORK AS RECOMMENDED BY THE SEALANT MANUFACTURER. 2. TOOL JOINTS CONCAVE, UNLESS INDICATED OTHERWISE. FINISH FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER, RIDGES AND SAGS. E. PROTECT SEALANT IN JOINTS SUBJECT TO DIRT, MOISTURE AND TRAFFIC DURING THE SEALANT CURING PROCESS. PROTECTION SHALL BE ABLE TO RESIST TRAFFIC WHILE REMAINING SECURELY IN POSITION. F. SCHEDULE: 1. TYPE A: PROVIDE AT ALL INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE. DIVISION 08 - DOORS AND WINDOWS 08 111 METAL DOORS A. ALL DOORS AND FRAMES FURNISHED AND INSTALLED BY GC UNLESS OTHERWISE NOTED. B. ACCEPTED VENDORS: 1. TWIN CITIES HARDWARE JIM MCDONALD 651 - 731 -7137 2. SUBSTITUTIONS ACCEPTABLE PROVIDED THEY MEET SPECIFICATION. C. DOORS SHALL NOT BE LIGHTER THAN 18 GAUGE FLUSH CONSTRUCTION, WITH INTERNAL STIFFENERS WELDED IN AT NOT OVER 8" OC AND WITH CONTINUOUS CHANNEL STIFFENERS WELDED TO FACE PLATES AT TOP AND BOTTOM. D. ALL DOORS SHALL BE PROVIDED WITH 10 GAUGE STEEL HINGE REINFORCEMENT & AN INTEGRAL LOCK BOX OF 16 GAUGE STEEL, ALL SECURELY WELDED INTO THE STILE. HINGE & LOCK REINFORCEMENTS SHALL BE DRILLED & TAPPED TO RECEIVE FINISHED HARDWARE, WHICH WILL BE APPLIED IN THE FIELD. E. DOORS SHALL BE REINFORCED FOR SURFACE APPLIED HARDWARE WITH A MINIMUM OF 16 GAUGE STEEL. DRILLING AND TAPPING FOR SURFACE APPLIED HARDWARE WILL BE DONE IN THE FIELD. F. ALL DOORS SHALL HAVE SOUND DEADENING MINERAL FIBER FILLER IN ALL VOIDS WITHIN DOORS. G. THE DOORS SHALL BE PREPARED FOR VARIOUS TYPES OF HARDWARE USING TEMPLATE PROVIDED BY THE HARDWARE SUPPLIER. H. GALVANIZED FINISH FOR EXTERIOR USE, DOORS TO BE THERMAL AND FIRE PROTECTED AS REQUIRED PER CODE. I. VERIFY THAT OPENING SIZES AND TOLERANCES ARE ACCEPTABLE. J. INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE SPECIFIED DOOR GRADE STANDARD AND THE "NATIONAL ASSOCIATION K. OF ARCHITECTURAL METAL MANUFACTURERS ". SEE DRAWINGS FOR FINISH. 08 710 DOOR HARDWARE A. SUPPLIER QUALIFICATIONS: HARDWARE IS PROVIDED BY GC. SEE SCHEDULED FOR SPECIFICATIONS. B. REQUIRED VENDOR: 1. TWIN CITIES HARDWARE LUCIO GRIJALVA 800 - 747 -1980 LGRIJALVA @TCHCO.COM LANG BOOMER 800- 747 -1980 LBOOMER @TCHCO.COM 2. SUBSTITUTIONS: NOT ACCEPTABLE. C. KEYS AND KEYING: 1. MARK EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE. 2. ALL CYLINDER ITEMS SHALL BE KEYED AS DIRECTED BY BEST BUY MOBILE. 3. RE -KEY EXISTING DOOR LOCKS AS DIRECTED BY BEST BUY MOBILE. 4. KEYS: FURNISH 3 FOR EACH CYLINDER UNIT. 5. CONSTRUCTION CORES PROVIDED BY G.C. INSTALLED BY G.C. PERMANENT CORES PROVIDED BY BBM, INSTALLED BY G.C. a. SUPPLIER: TWIN CITIES HARDWARE 723 HADLEY AVE. N. OAKDALE, MN 55128 PH: 651 - 731 -7137 FX: 651 - 735 -1800 EMAIL: JMCDONALD @TCHCO.COM D. FINISH: AS SCHEDULED ON THE DRAWINGS. E. INSTALLATION: 1. MARK EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE. 2. EXPOSED SURFACES OF HARDWARE SHALL BE COVERED AND WELL PROTECTED DURING INSTALLATION, SO AS TO AVOID DAMAGE TO FINISHES. 3. INSTALL EACH HARDWARE ITEM IN COMPLIANCE WITH MANUFACTURERS INSTRUCTIONS. WHEREVER CUTTING AND FITTING ARE REQUIRED TO INSTALL HARDWARE ONTO OR INTO SURFACES WHICH ARE LATER TO BE PAINTED OR FINISHES IN ANOTHER WAY, INSTALL EACH ITEM COMPLETELY AND THEN REMOVE AND STORE IN A SECURE PLACE DURING THE FINISH OPERATION. AFTER COMPLETION OF THE FINISHES, REINSTALL EACH ITEM. DO NO INSTALL SURFACE MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. 4. HARDWARE MOUNTING HEIGHTS: MOUNTING HEIGHTS AS INDICATED ON THE DRAWINGS OR REQUIRED TO MEET CODE AND ACCESSIBILITY REQUIREMENTS. VERIFY ANY CONFLICTS WITH LOCATION OF OTHER HARDWARE FOR PROPER CLEARANCES FOR INSTALLATION PRIOR TO CUTTING OR MILLING FOR SPECIFIED HARDWARE. NOTIFY OWNER IMMEDIATELY IF SUCH CONFLICTS ARE DETERMINED. 5. ADJUSTING AND CLEANING: ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION. CLEAN DOOR AND HARDWARE. F. HARDWARE GROUPS: AS SCHEDULED IN THE DRAWINGS. 08 800 GLAZING A. EXISTING TO REMAIN DIVISION 09- FINISHES 09 206 SECURITY MESH PENETRATION BARRIER A. B. C. D. SUMMARY: 1. FURNISH AND INSTALL STEEL EXPANDED METAL PANELS AS A PENETRATION BARRIER ABOVE GYP BD TO DECK ABOVE USING THE MANUFACTURER'S RECOMMENDED METHOD OF INSTALLATION. MANUFACTURER: 1. ALABAMA METAL INDUSTRIES CORPORATION (AMICO) 2. CONTACT: RHEA RICHARDSON OFFICE: 800 - 366 -2642 FAX:205 -786 -6527 EMAIL: RRICHARDSON @GIBRALTAR1.COM WEB: WWW.AMICO- SECURITYPRODUCTS.COM 3. SUBSTITUTIONS ACCEPTABLE PROVIDED THEY MEET SPECIFICATIONS MATERIALS: 1. SECURITY MESH IS MANUFACTURED IN 4'X8' PANELS AND SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS: a. ASM 1.0 -16F MEDIUM SECURITY b. OPENING: WIDTH 0.875 INCH X 2.250 INCH LONG ALLOWING 77% OPEN AREA c. THICKNESS: 0.048 INCH c. WEIGHT: 0.41 LBS PER SQUARE FOOT MILL FINISH 2. CLIPS: SECURITY MESH SHALL BE ATTACHED TO FRAMING MEMBERS USING MANUFACTURERS CLIPS AND THE APPROPRIATE THREADED FASTENERS PER APPLICATION. INSTALLATION: 1. SECURITY MESH PANELS MAY BE INSTALLED WITH DIAMOND RUNNING IN EITHER DIRECTION 2. IT IS PREFERRED TO HAVE MESH JOINTS EITHER JOIN STAGGERED OR BUTT TOGETHER. IT IS ACCEPTABLE TO OVERLAP MESH JOINTS. PANELS SHALL JOIN ON A FRAMING MEMBER. 09 211 GYPSUM BOARD CONSTRUCTION A. B. QUALITY CONTROL: 1. WHERE FIRE RATED CONSTRUCTION IS A PART OF THE WORK OR THIS CONTRACT, PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED. ASSEMBLIES SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. MATERIALS: 1. GYPSUM BOARD: a. 5/8 INCH THICK UNLESS NOTED OTHERWISE b. STANDARD BOARD: ASTM C1396; TYPE X IN FIRE RATED PARTITIONS WHERE INDICATED. c. EXTERIOR SOFFIT BOARD: ASTM C 1395; 2 LAYERS OF 1/4" FLEX BOARD. 2. ACCESSORIES: a. TRIM: CONCEALED FLANGE SCREW ON TYPE; METAL OR PVC AT CONTRACTOR'S OPTION; GA 216. b. JOINT COMPOUND, TAPE AND FINISHING COMPOUND: ASTM C475 AND GA 216; USE SETTING TYPE JOINT COMPOUND AT SCREWS: ASTM C1002. c. WHEN SHOWN, STUD MOUNTED ACOUSTIC MATERIAL: 1/16 INCH THICK EPDM SHEET; 6" WIDTH; PART NO 8990K52 FROM MCMASTER -CARR SUPPLY COMPANY 562-692-5911 OR WWW.MCMASTER.COM C. INSTALLATION: 1. INSTALLATION STANDARD: UNLESS SPECIFIED OTHERWISE, PERFORM WORK IN ACCORDANCE WITH GYPSUM ASSOCIATION 216, "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD." 2. SCREW FASTEN BOARD TO FRAMING, UNLESS APPROVED OTHERWISE. 3. CONTROL, JOINTS: LOCATE CONTROL JOINTS AS FOLLOWS: a. AT MAXIMUM 30 FOOT INTERVALS ALONG CONTINUOUS WALL PANELS. b. AT MAXIMUM 50 FOOT INTERVALS AT CONTINUOUS CEILINGS WITH PERIMETER RELIEF. c. AT MAXIMUM 30 FOOT INTERVALS AT CONTINUOUS CEILINGS WITHOUT PERIMETER RELIEF. d. AT LOCATIONS WHERE EXPANSION OR CONTROL JOINTS OCCUR IN THE BUILDING STRUCTURE. e. ALIGN TO INTERSECT LIGHT FIXTURES, AIR DIFFUSERS, DOOR OPENINGS AND OTHER AREAS OF STRESS CONCENTRATION. f. POSITION CONTROL JOINTS AT LOCATIONS WHERE EXPANSION OR CONTROL JOINTS OCCUR IN THE BUILDING STRUCTURE. g. LOCATE CONTROL JOINTS TO FORM RECTANGULAR OR SQUARE SECTIONS IN "L ", "U ", 7 OR OTHER IRREGULAR SHAPED AREAS. h. COORDINATE FINAL CONTROL JOINT LOCATIONS WITH OWNER. 4. FINISHING: a. PROVIDE FINISHING IN ACCORDANCE WITH GA 214. b. WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE OF THE GYPSUM BOARD. c. LEVELS OF FINISH: 1) LEVEL 5: NOT USED 2) LEVEL 4: NOT USED 3) LEVEL 3: PROVIDE UNLESS INDICATED OR SPECIFIED OTHERWISE. 4) LEVEL 2: NOT USED 5) LEVEL 1: PROVIDE AT THE FOLLOWING LOCATIONS: a) SURFACES OF FIRE RATED ASSEMBLIES CONCEALED FROM VIEW IN THE FINISHED WORK ( "FIRE TAPING "). 6) LEVEL 0: PROVIDE AT SURFACES OF NON- FIRE RATED ASSEMBLIES CONCEALED FROM VIEW IN THE FINISHED WORK, INCLUDING SURFACES TO BE COVERED BY CASEWORK, WOOD PANELING. 09 511 SUSPENDED ACOUSTICAL CEILINGS A. EXISTING TO REMAIN 09 640 WOOD BASE A. HARDWOOD BASE FURNISHED AND INSTALLED BY GC. 1. WD -1 SALES AREA BASE, 1" X 4" SELECT GRADE PINE PAINTED MINIMUM TWO COATS C-1 OR C-2. SEE SHEETS A -7 FOR PAINT COLOR. a. INSTALL BASE ON FIXTURES AS DIRECTED BY BEST BUY MOBILE. b. SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS. c. INSTALL STRAIGHT AND LEVEL TO VARIATION OF PLUS OR MINUS 1/8" OVER 10 FEET. d. ADHERE TO VERTICAL SURFACE ONLY. DO NOT ADHERE TO FLOORING. e. INSTALL STRAIGHT AND LEVEL TO VARIATION OF PLUS OR MINUS 1/8" OVER 10 FEET. f. INSTALLED WHERE WOOD FLOOR MEETS FRL OR METAL. 09 650 RESILIENT FLOORING A. EXISTING TO REMAIN 09 650 RESILIENT BASE/TRANSITIONS A. BASE MATERIALS 1. BASE: VINYL; TOP SET, 1/8" THICK AS MANUFACTURED BY VINYL PLASTICS INC 2. VB -1: 4" HIGH OR AS INDICATED ON THE DRAWINGS. 3. PROVIDE COVED BASE AT ALL LOCATIONS, UNLESS OTHERWISE INDICATED. 4. PROVIDE PREMOLDED ENDSTOPS AND EXTERNAL CORNERS. 5. COLOR" VPI #01 "JET BLACK" B. INSTALLATION 1. FIT JOINTS TIGHT AND VERTICAL. MAINTAIN MINIMUM MEASUREMENT OF 1/8" BETWEEN JOINTS 2. MITER INTERNAL CORNER AS EXTERNAL COVERED "V" CUT BACK OF BASE TO 2/3 THICKNESS AND FOLD 90 DEGREES. 3. INSTALL BASE ON SOLID BACKING. ADHERE TIGHTLY TO WALL AND FLOOR SURFACES. 4. INSTALL BASE ON FIXTURES AS DIRECTED BY BEST BUY MOBILE. 5. SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS. 6. INSTALL STRAIGHT AND LEVEL TO VARIATION OF PLUS OR MINUS 1/8" OVER 10 FEET. 09 6813 CARPET TILES • A. OWNERS NATIONAL ACCOUNT FOR THIS PRODUCT IS LEES CARPET, A DIVISION OF MOHAWK INDUSTRIES. CONTACT: BARBARA COATES 800 - 241 -4494 EXT 44051, BARBARA_COATES@MOHAWKIND.COM B. SUMMARY: CARPET TILES C. QUALITY ASSURANCE: 1. CARPET INSTALLER: MINIMUM OF 3 YEARS EXPERIENCE IN CARPET INSTALLATIONS OF SIMILAR SIZE AND SCOPE. D. MATERIALS: 1. CARPET TILE: AS SCHEDULED ON THE DRAWINGS, NO PAD, FURNISHED AND INSTALLED BY GC. 2. ACCESSORIES: a. ADHESIVES: AS RECOMMENDED BY THE CARPET MANUFACTURER FOR INSTALLATION UNDER CONDITIONS OF THIS PROJECT. b. USE RELEASE TYPE ADHESIVES AT CARPET TILE LOCATIONS. c. LATEX UNDERLAYMENT: WHERE PREMIX LATEX FILLER d. EDGE STRIPS: VINYL REDUCER STRIPS, SIZE AND CONFIGURATION AS APPROPRIATE FOR CONDITIONS; STANDARD COLOR AS SELECTED TO BEST MATCH CARPET FIELD COLOR. E. PREPARATION: 1. CLEAN FLOORS OF DUST, DIRT, SOLVENTS, OIL, GREASE, PAINT, PLASTER AND OTHER SUBSTANCES WHICH WOULD BE DETRIMENTAL TO THE PROPER PERFORMANCE OF ADHESIVE AND CARPET. 2. FILL LOW SPOTS AND CRACKS OVER 1/8 INCH IN WIDTH WITH LATEX UNDERLAYMENT. 3. PERFORM SUBSTRATE MOISTURE TEST IN ACCORDANCE WITH ASTM D4263 TO VERIFY THAT SLAB IS DRY TO THE POINT WHERE INSTALLATION MAY COMMENCE. NOTIFY THE OWNER IF MOISTURE LEVELS EXCEED 3 LBS/ 1000 SQ. FT. G. CARPET INSTALLATION 1. STARTING INSTALLATION CONSTITUTES ACCEPTANCE OF SUB -FLOOR CONDITIONS 2. INSTALL CARPET TILES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS; INSTALL CARPET TILES IN ACCORDANCE WITH CARPET AND RUG INSTITUTE (CRI) RECOMMENDATIONS. 3. BLEND CARPET FROM DIFFERENT CARTONS TO ENSURE MINIMAL VARIATION IN COLOR MATCH 4. FLOOR ADHESIVE SHALL BE APPLIED IN ACCORDANCE WITH ADHESIVE MANUFACTURER'S RECOMMENDATIONS USING A ROLLER TO ENSURE MAXIMUM CONTACT. ROLL STOCK CARPET SHALL BE FULLY ADHESIVELY BONDED. 5. JOINTS SHALL BE TIGHT AND UNNOTICEABLE UPON COMPLETION. 6. CUT CARPET FOR TELEPHONE AND ELECTRICAL OUTLETS. 7. INSTALL EDGING STRIPS WHERE CARPET TERMINATES AT OTHER FLOOR COVERING. USE FULL LENGTH PIECES ONLY. BUT TIGHT TO VERTICAL SURFACES. WHERE SPLICING CANNOT BE AVOIDED, BUTT ENDS TIGHT, FLUSH AND ACCURATELY ALIGNED. H. REMNANTS: REMOVE AND DISPOSE OF REMNANTS AT A LEGAL OFF SITE LOCATION. I. CLEANUP: 1. THE PREMISES SHALL BE KEPT FREE FROM UNNECESSARY ACCUMULATION OF TOOLS, EQUIPMENT AND SURPLUS MATERIALS DURING THE PROGRESS OF THE WORK. 2. REMOVE THREADS WITH SCISSORS. REMOVE SPOTS WITH MANUFACTURERS RECOMMENDED SPOT REMOVER. 3. THOROUGHLY POWER VACUUM ENTIRE SURFACE USING EQUIPMENT WITH MOTOR DRIVEN BRUSHES. J. CARPET SCHEDULE: 1. CA -1: BROADLOOM TILES - LEES CARPET STYLE# GT038, STYLE NAME: DESTINATION, COLOR# 524, COLOR NAME: BRENTWOOD 2. MT -1: LEES CARPET #L8513, FIRST STEP, COLOR #00508 CHARCOAL GRAY 09 900 PAINTING A. ALLOWABLE MANUFACTURERS: BEST BUY MOBILE HAS ESTABLISHED A NATIONAL ACCOUNT AGREEMENT FOR PRODUCTS OF THIS SECTION FROM THE FOLLOWING MANUFACTURERS: 1. BENJAMIN MOORE & CO. JASON WALKER (773- 597 -8698) JASON.WALKER @BENJAMINMOORE.COM 2. SHERWIN WILLIAMS COMPANY, STORES DIVISION SHAUN WILLIAMS (847 -330 -6262) SHAUN.WILLIAMS @SHERWIN.COM B. QUALITY ASSURANCE: 1. PAINT COATINGS SHALL BE FREE OF DUST, DIRT, FLOW LINES, STREAK, SAGS, BLISTERS AND PINHOLES, BUGS, RUNS OR OTHER SURFACE IMPERFECTIONS. 2. IN ADDITION TO THE COATS SPECIFIED, PROVIDE ADDITIONAL COATS AS REQUIRED TO OBTAIN ADEQUATE HIDE. 3. MATERIALS TO BE VOC COMPLIANT. C. MAINTENANCE MATERIALS: 1. FURNISH MINIMUM 1 GALLON OF C-1 COLOR (MAIN FIELD PAINT COLOR). 2. FURNISH MINIMUM 1 GALLON OF EACH ADDITIONAL PAINT TYPE AND COLOR COMBINATION. 3. OVERAGE MAY BE TAKEN FROM THE BATCH MIX FURNISHED FOR THE WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERTY LABELED SEALED CANS. 4. PROVIDE MANUFACTURERS MIX FORMULATION CLEARLY MARKED ON EACH CONTAINER. D. MATERIALS, MANUFACTURERS AND PRODUCTS: 1. PROVIDE PRODUCTS BY THE ABOVE MANUFACTURER. 2. NO SUBSTITUTIONS ALLOWED. E. SURFACE PREPARATION: 1. PREPARE SURFACES BY REMOVING ALL DIRT, DUST, GREASE, OIL, MOISTURE AND OTHER CONTAMINANTS WHICH WILL IMPAIR THE PROPER ADHESION OF THE FINISH. 2. WOOD- OPAQUE FINISH: a. REMOVE LOOSE, BLISTERED, SCALED, OR CRAZED FINISHES TO BARE SUBSTRATE: FEATHER NEW WORK INTO EXISTING WORK. PREPARE SURFACES TO THE NEAREST BREAK LINE IF NECESSARY TO BLEND NEW FINISHES WITH OLD FINISHES. b. WASH AND RINSE SURFACES WITH TRISODIUM PHOSPHATE AND WATER OR OTHER SOLUTION REQUIRED TO CAUSE BLEED THROUGH OF NEWLY APPLIED FINISHES. c. LIGHTLY SAND OR APPLY A LIQUID DEGLOSSER ON EXISTING SEMI GLOSS AND HIGH GLOSS FINISHES BEFORE REFINISHING. F. SPECIAL APPLICATION REQUIREMENTS: 1. UNLESS SPECIFIED OR INDICATED OTHERWISE, FOLLOW PAINT MANUFACTURERS LABEL DIRECTIONS FOR GENERAL APPLICATION PROCEDURES AND COVERAGE RATES. 2. DO NOT APPLY FINISHES ON SURFACES THAT ARE NOT SUFFICIENTLY DRY. MAKE SURE EACH COAT OF FINISH IS DRY AND HARD BEFORE FOLLOWING COAT IS APPLIED UNLESS THE MANUFACTURERS DIRECTIONS STATE OTHERWISE. 3. TINT FILLER TO MATCH STAIN WHEN CLEAR FINISHES ARE SPECIFIED; WORK FILLER WELL INTO GRAIN AND BEFORE IT HAS SET, WORKING PERPENDICULARLY TO THE GRAIN, WIPE THE EXCESS FROM THE SURFACE. 4. OPAQUE FINISHES: a. APPLY NUMBER OF COATS SCHEDULED FOR EACH APPLICATION, EXCEPT THAT ADDITIONAL FINISH COATS SHALL BE APPLIED AS NECESSARY FOR COMPLETE HIDING OF SUBSTRATE COLORS. b. APPLY PRIMER COATS UN- TINTED. WHERE MORE THAN ONE COAT OF PAINT IS REQUIRED, TINT EACH SUCCEEDING COAT UP TO THE FINAL COAT SIMILAR IN TINT, BUT SLIGHTLY LIGHTER IN VALUE (SHADE). c. SAND LIGHTLY BETWEEN COATS IF NECESSARY TO ACHIEVE REQUIRED FINISH; SAND BETWEEN ALL COATS APPLIED TO WOOD SUBSTRATES. 5. ROLLERS FOR APPLICATION AND BACK ROLLING OF LATEX PAINTS SHALL HAVE A NAP OF 3/8 INCH OR LESS. 6. WHERE ROLLER TEXTURE IS SCHEDULED FOR APPLICATION TO PLASTER AND GYPSUM BOARD SURFACES, FINISH COATS MAY BE ROLLER - APPLIED, OR SPRAY APPLIED AND BACK ROLLED AT CONTRACTORS OPTION. 7. FACTORY PRIMED SURFACES: APPLY SCHEDULED FINISH SYSTEM, LESS PRIMER COAT, EXCEPT AS NECESSARY FOR PATCHING DAMAGE TO FACTORY PRIME COATING. 8. ALL PAINTED CEILING ACCESSORIES INDICATED TO BE PAINTED SHALL BE SPRAY FINISHED PRIOR TO INSTALLATION. G. SYSTEMS: 1. PT -1: INTERIOR WALLS AND COLUMNS, ETC., BELOW CEILING: a. SHERWIN WILLIAMS (WALLS: SATIN) 1) 1 COAT: SHERWIN WILLIAMS, PROMAR 200 #B28W8200 2) 2 COATS: SHERWIN WILLIAMS, PROMAR 200 #B20W2051 b. SHERWIN WILLIAMS (SOFFITS: FLAT) 1) 1 COAT: SHERWIN WILLIAMS, PROMAR 200 #B28W8200 2) 2 COATS: SHERWIN WILLIAMS, PROGREEN 200 #B30W651 2. PT -2: HOLLOW METAL DOORS, HOLLOW METAL DOOR AND WINDOW FRAMES AND OTHER INTERIOR UNGALVANIZED FERROUS METAL. a. SHERWIN WILLIAMS (SEMI - GLOSS) 1) 1 COAT: SHERWIN WILLIAMS, PROCRYL #B66W310 2) 2 COATS: SHERWIN WILLIAMS, DTM ACRYLIC SEMI -GLOSS #B66W211 3. PT-4: INTERIOR SOLID WOOD TRIM: a. SHERWIN WILLIAMS 1) 1 COAT: SHERWIN WILLIAMS, PREMIUM INTERIOR WALL AND WOOD PRIMER #B28W8101 2) 2 COATS: SHERWIN WILLIAMS, PROCLASSIC WATERBORNE #B31W51 H. COLOR SCHEDULE: 1. C-1: SHERWIN WILLIAMS #SW7575, "CHOP STICKS" 2. C -5: SHERWIN WILLIAMS #SW7006 "EXTRA WHITE" DIVISION 10 - SPECIALTIES 10 281TOILET ACCESSORIES A. GRAB BARS 1. REFERENCES: a. ASTM A 554 STAINLESS STEEL TUBING b. ASTM F 446 2. MANUFACTURERS a. ASI - AMERICAN SPECIALTIES, INC.: (914) 476 -9000 b. BOBRICK WASHROOM EQUIPMENT, INC.: (818) 982 -9600 c. SUBSTITUTIONS: SEE SECTION 01600 3. GENERAL REQUIREMENTS a. TYPE 304,18 -8 ALLOY b. FORMED 1 1/2" RADIUS RETURN TO WALL AT EACH END. c. EACH END HELIARE - WELDED TO MINIMUM 11 GAGE STAINLESS STEEL CIRCULAR FLANGE. d. WITHSTAND A 900 POUND FORCE. e. STAINLESS STEEL, 3" DIAMETER BY 1/2" DEEP TENUM PLATE FOR CONCEALED ATTACHMENT USING THREE SET SCREWS. 4. INSTALLATION: a. INSTALL IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. B. ROLLED PAPER TOWEL DISPENSER: 1. SURFACE MOUNTED, LEV- R- MATIC, KIMBERLY CLARK #9765 C. AIR FRESHENER DISPENSER: 1. SURFACE MOUNTED, TCELL, TECHNICAL CONCEPTS #TEH402092 D. HAND SOAP DISPENSER: 1. SURFACE MOUNTED, CLARIO, BETCO #91831 -92 E. SANITARY NAPKIN DISPOSAL 1. SURFACE MOUNTED, CONTURA SERIES, BOBRICK #B -270 F. BABY CHANGING TABLE 1. INFANT CHANGING TABLE: FORMED FROM HIGH DENSITY POLYETHYLENE PLASTIC INFANT CHANGING TABLE COMPLETE WITH NYLON AND VELCRO SAFETY STRAPS, HORIZONTAL STATION, CAPABLE OF HOLDING MINIMUM 250 LBS OF STATIC WEIGHT, ADA COMPLIANT, NOMINAL SIZE 20" X 35" X 4" . DIAPER CHANGING TABLE #605" AS MANUFACTURED BY RUBBERMAID #7818. 10 441 FIRE EXTINGUISHERS AND CABINETS A. EXTINGUISHERS: 1. FIRE EXTINGUISHERS FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 2. MULTIPURPOSE DRY CHEMICAL TYPE (FE): HEAVY DUTY DOT STEEL TANK; UL RATING 2A- 10B:C, 5 LB CAPACITY, WITH PRESSURE GAGE; RED ENAMEL FINISH; METAL VALVES AND SIPHON TUBES. B. INSTALLATION: 1. INSTALL MOUNTING BRACKETS AT HEIGHTS TO COMPLY WITH APPLICABLE REGULATIONS OF GOVERNING AUTHORITIES. 2. SECURE MOUNTING BRACKETS TO STRUCTURE, SQUARE AND PLUMB, TO COMPLY WITH MANUFACTURER'S INSTRUCTIONS. 3. INSTALL ONE (1) EXTINGUISHER AT CASHWRAP AND ONE (1) EXTINGUISHER NEAR ELECTRICAL PANEL, OR AS OTHERWISE DIRECTED BY THE FIRE MARSHAL. DIVISION 11- EQUIPMENT 11 000 LADDERS A. B. GENERAL CONTRACTOR TO FURNISH (1) 8' -0" TYPE IA PLATFORM LADDER. WERNER PLATFORM STEP LADDER, SERIES P6208 OR EQUAL. DIVISION 23 - MECHANICAL SEE ATTACHED MECHANICAL SPECIFICATIONS DIVISION 26 - ELECTRICAL SEE ATTACHED ELECTRICAL SPECIFICATIONS MUST PURCHASE LIGHTING FROM SPECIFIED LIGHTING SUPPLIER IN LUMINAIRE SCHEDULE END OF SPECIFICATION REetivtu. CITY OF TUKWILA. MAY 3 0 2012 PERMIT CENTER a Q z 0 a U w 0 CO 05 -22 -12 DATE ISSUED a) 0 z C, cc ZO OT- NO E Q�Lo�N U J I L,J co- - H QOo U D 5 MM 0 co (n Z ^ E Z ^ANN U cK cov� Li ',O...., 4_ i lnoJ >NQ = FZO- W Z 2 D-Z O X J Q 7 � SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 S F CONCEPT: 1 .0 LARGE CONCEPT DATE: 04-28-11 STORE NUMBER: # ## 0 L,J Q Li.l CD F- co O (i) L LJ U � 1- 1- z 0 o D < N PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: NO SCALE SPECIFICATIONS A -12 w w 9' -11" 9' -11" 1.2 POS DETAIL a w w 0 t 4' -10" 4' -10" TYP. X MOD. SCALE: N.T.S. POS DETAIL TYP. X MOD. MANAGER'S DESK: MOUNT T.O. DESKTOP AT 32" AFF 8' -0" CLG HT 9' -11" CLG HT .%% %%% %, %iii iii ,%%%%% /% %/ , i%," %%/% z 0 U) w w z w U) J WS.2 SERVER SHARK CAGE: SHARK CAC EISIMEMEEII COAT HOOKS - SEE A7 FOR ADD'L INFO. co FIXTURE PLAN SCALE: 1/4 = 1 %,/ ./ ,iii %%% % /, /i 9' -11" CLG HT 4' -6" 4' -0" 3' -0" HR.4 0 co 0 0) -U 0 co C) 0 in FR.2 12' -2" 1d0 EISIEDIEMEM 33' -10" SCALE: N.T.S. SW.3 SW.3 ` I SW.3 I SW.3 L.. ....I ... 7' -10" 8' -5" SW.3 7' -10" VAL.13 TB CAS CAS TBLI& I w M 9' -11" CLG HT CAS CMS ir m� C'MS VAL.12 - TBL.12...TBL:I2.. CMS CMS 1 If ..I I.... S C'MS CMS 4' -0" 1' -9" 2' -3" 2' -O" 42' -4" GC TO INSTALL BBM FURNISHED WIRE WINDOW DISPLAY AND TRACK, TYP. GC TO CUT TRACK TO WIDTH OF WINDOW AIDELEECIME 86' -4 1/4" 21-11" LEASEUNE DIMENSION TYP. X MOD. GENERAL NOTES 1. FIXTURES, SHELVING AND STANDARDS TO BE FURNISHED BY BEST BUY MOBILE AND INSTALLED BY GENERAL CONTRACTOR. GC TO PROVIDE BLOCKING AS REQUIRED. 2. FIXTURE DIMENSIONS ARE MEASURED FROM KICK PLATE TO KICK PLATE. 3. THE CONTRACTOR WILL COORDINATE UNLOADING OF DEUVERY TRUCKS. FIXTURING STARTS WEDNESDAY GO -4 (BACKROOM FIXTURES) AND MONDAY GO -3 (SALES FLOOR FIXTURES). 4. SUPERINTENDENT TO ASSURE THAT THE ELECTRICAL SUBCONTRACTOR ARRIVES MONDAY (GO -3) FOR FINAL CONNECTIONS TO FIXTURES. 5. THE SUPERINTENDENT IS REQUIRED TO MAINTAIN HIS PRESENCE AT THE PROJECT THROUGHOUT THE FIXTURE AND MERCHANDISE PROCESS (2 WEEKS) AND AT ANY TIME HIS SUBCONTRACTORS ARE WORKING ON THE PROJECT. 6. SUPERINTENDENT TO BE CONSCIOUS OF DAMAGE TO WALLS, FLOORING, ETC. DETERMINE WHO THE RESPONSIBLE PARTY IS AND ADDRESS THE ISSUES WITH THE OWNER'S PROJECT MANAGER AS TO HOW AND WHEN TO PROCEED WITH CORRECTIVE REPAIRS. 7. THE SUPERINTENDENT WILL MAINTAIN A CLEAN STORE. THIS WILL BE PREACHED TO EVERY PERSON ENTERING AND WORKING WITHIN THE STORE AND WILL CONTINUE THIS PROCESS THROUGHOUT THE FIXTURING PROCESS AT NO ADDITIONAL COST TO THE OWNER. FINAL CLEAN REQUIRED PRIOR TO TURNOVER (GO -1 MONDAY) AND AGAIN AT FRIDAY GO -1 SO STORE IS READY FOR GO THE FOLLOWING WEEK. ANY CLEANING REQUIRED DURING GO -0 WEEK WILL BE BBYM'S RESPONSIBIUTY. 8. IF SUPERINTENDENT WITNESSES UNPROFESSIONAL BEHAVIOR OR METHODS BY VENDORS OF OWNER, HE /SHE SHOULD FIRST ATTEMPT TO BRING THE NATURE OF THE CONCERN TO THE RESPONSIBLE PARTY AND ADVISE THE OWNER'S PROJECT MANAGER OF THE DETAILS. 9. THE SUPERINTENDENT SHALL POLICE THE STORE IN REGARDS TO ELIMINATING EA11NG, DRINKING AND SMOKING WITHIN THE STORE. THE SUPERINTENDENT SHOULD BEGIN THE PROCESS ONCE FINISHES COMMENCE WITHIN THE STORE AND START POLICING PRIOR TO FIXTURING OF THE STORE AFTER WHICH THE ABOVE ARE PROHIBITED. 10. THE SUPERINTENDENT IS RESPONSIBLE FOR THE LOCKS TO BE RE -KEYED MONDAY GO -1 AT 7 AM. AT THIS TIME THE OWNER STARTS RECEIVING DISPLAY PRODUCT. IF THE CONTRACTOR FAILS TO TURN OVER THE LOCKS, THE OWNER WILL CONTRACT WITH A SECURITY GUARD SERVICE AND ONE WILL BE STATIONED WITHIN THE STORE AT THE CONTRACTOR'S COST. 11. ONCE THE LOCKS HAVE BEEN RE -KEYED THE ACTUAL STORE . MANAGEMENT WILL BE RESPONSIBLE FOR LOCKING AND UNLOCKING THE STORE TO ALLOW ACCESS. WORK HOURS WILL NEED TO BE REGULARLY DISCUSSED AND ANY CHANGES TO WORK HOURS NEED TO BE DISCUSSED WITH STORE MANAGEMENT IN A TIMELY MANNER. 12. OWNER STORE MANAGEMENT HAS VERY LITTLE TO DO WITH AND DURING THE FIXTURING PROCESS. OWNER HAS A BBYM SAS NSO LEAD, WHO TAKES ON THIS RESPONSIBILITY AT THE COMMENCEMENT OF MERCHANDISING ALLOWING THE STORE MANAGER TO CONCENTRATE EFFORTS ON EMPLOYEE TRAINING, ETC. 13. THE SUPERINTENDENT, ELECTRICIAN, FIXTURE INSTALLER, ETC. WILL COORDINATE EFFORTS THROUGH THE BBYM SAS NSO LEAD. FIXTURE LEGEND NAME DESCRIPTION CP.1 CUSTOMER SELF SERVE KIOSK POS.4 POS RIGHT -HAND: 35" DEEP X 29" WIDE X 34" HIGH POS.5 POS LEFT -HAND: 35" DEEP X 29" WIDE X 34" HIGH POS.6 POS EXTENSION: 35" DEEP X 30" WIDE X 34" HIGH PPOS ww, EXTENSION: 35" DEEP X 30" WIDE X 34" HIGH W/ CPU BRACKET SC1STORAGE w . CABINET: 1' -0" DEEP X 4' -0" WIDE X 3' -0" HIGH SW.3 SLATWALL: 1' -6" DEEP X 4' -0" WIDE X 8' -0" HIGH S.4 SLATWALL• 1' -6" DEEP X 4' -0" WIDE X 4' -0" HIGH TBL.12 TB TABLE HIGH ANGLED TOPPER: 39" DEEP X 45" WIDE TBL.13 TABLE HIGH TFI FLAT TOPPER: 39" DEEP X 45: WIDE X TBL.EC TAB WIDE END X CAP WITH H FLAT TOPPER: 16" DEEP X S.1 WALL STANDARD: 1' -6" WIDE X 4' -0" LONG W8.2 WALL STANDARD: 1' -6" WIDE X 2' -0" LONG w8.3 MMANOAGERS ESK WALL STANDARD: 1' -10" WIDE X 0 PORTABLE BUYER'S GUIDE STAND FIXTURE EXTENSION 0 SIGN LEGEND NAME DESCRIPTION FR.1 2 x 4 WOOD GRAPHIC FRAME FR.2 4 x 4 WOOD GRAPHIC FRAME HR.4 =ten G VAL.12 4 x 4 HR/LEGAL SIGN HOLDER 2 STACKED GRAPHIC, TRACK CABLE HANGING S S ABOVE 105" x P1" x 18". OVERHEAD SIGN VA . § °-3 VAL.13 ABOVE LAPTOP8TABLESOVERHEAD SIGNAGE, VALANCE �4hy jr its yr si displkyed in wimdaas 5Nc.61 mvi d f�- lG� StPru'a7e sir REVIEWED FOR ODE COMPLIANCE APPROVED JUN 3 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 3 0 2012 PERMIT CENTER z 0 J w U z Z a 0 0 W z a. a 05 -22 -12 DATE ISSUED a La 0 z 0 Li c_)9 0Q` -r-"' E W Z r4)'f O co ' ° 0 lfi (O N _� Jwl,c) I I t C_) - I- 00 M U Q0za �- _Z Z � ® m= MM L. a a z�^= z :2N - (,) ° 0 Wi w ` `'_ Y2 - Q (/) 0 ,_► La-I Lei .D WN W I- ,,,a- ,. J �v� DO�ZOj�� main ZN2a-�w SQ. FT. CALCS RETAIL 1 ,170 SF TOTAL: 1, 682 S F CONCEPT: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUMBER: 0 0 w < woo F- co Z 00 (I) w U wm�� Z O w (fQ CD = w O O�I-D 0 (/) F-- PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE SCALE: AS NOTED FIXTURE PLAN F -1 ABBREVIATIONS HVAC SYMBOL LEGEND AFF AMP AP BTU C BV CFH C FM CHW CHWR CHWS CLG CO CR CW DB DEMO DIA DIFF DWG DX EAT ELEC ELEV EMS EWB EWT EX H EXIST F FSD FCO FD FD FFE FLR FPM FT GA GAL GC GPH HP HT HVAC HW HZ ABOVE FINISHED FLOOR AMPERE (AMP, AMPS) ACCESS PANEL BRITISH THERMAL UNIT CIRCUIT BALANCING VALVE CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CIRCULATING HOT WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING CLEANOUT CONDENSATE RETURN COLD WATER DECIBEL DEMOLITION DIAMETER DIFFUSER DRAWING DIRECT EXPANSION ENTERING AIR TEMPERATURE ELECTRICAL ELEVATION ENERGY MANAGEMENT SYSTEM EXTERNAL STATIC PRESSURE ENTERING WET BULB ENTERING WATER TEMPERATURE EXHAUST EXISTING FAHRENHEIT COMBINATION FIRE /SMOKE DAMPER FLOOR CLEANOUT FIRE DAMPER FLOOR DRAIN FINISHED FLOOR ELEVATION FLOOR FEET PER MINUTE FOOT OR FEET GAGE OR GAUGE GALLONS GENERAL CONTRACTOR GALLONS PER HOUR HORSEPOWER HEIGHT HEATING, VENTILATING, AIR CONDITIONING HOT WATER HERTZ ID INV KW LAT LBS LWB LWT MA MAX MBH MIN MISC NA NC NIC NTS OA OBD PH PVC RA REC REL RH RM RPM SA SAN SD SF SP SPEC STD TD TSP V TYP VFD VSD VOL VTR W/ W/O WC WCO WT INSIDE DIAMETER INVERT KILOWATT LEAVING AIR TEMPERATURE POUNDS LEAVING WET BULB LEAVING WATER TEMPERATURE MIXED AIR MAXIMUM THOUSAND BTU'S /HR MINIMUM MISCELLANEOUS NOT APPLICABLE NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER PHASE (ELECTRICAL) POLYVINYL CHLORIDE RETURN AIR RECESSED RELIEF RELATIVE HUMIDITY ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SANITARY SMOKE DAMPER SQUARE FEET STATIC PRESSURE SPECIFICATION STANDARD TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE TYPI CAL VOLTS VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE VOLUME VENT THROUGH ROOF WATTS WITH WITHOUT WATER CLOSET WALL CLEANOUT WEIGHT EQUIPMENT TAGS ACCU AHU CP DHC EF EUH EWC EWH AIR COOLED CONDENSING UNIT AIR HANDLING UNIT CIRCULATING PUMP DUCT HEATING COIL EXHAUST FAN ELECTRIC UNIT HEATER ELECTRIC WATER COOLER ELECTRIC WATER HEATER FC U IH MAU RF RH RTU VAV FAN COIL UNIT INTAKE HOOD MAKE -UP AIR UNIT RETURN FAN RELIEF HOOD ROOFTOP UNIT VARIABLE AIR VOLUME BOX MISC. SYMBOL LEGEND XXX 1 EQUIPMENT TAG 0 CONNECTION TO EXISTING A REVISION TRIANGLE OX KEY NOTE SHEET INDEX M -1 HVAC PLAN M -2 PLUMBING PLAN M -3 MECHANICAL SPECIFICATIONS SPIN -ON FITTING DUCTWORK SUPPLY DUCT UP SUPPLY DUCT DOWN SUPPLY DUCT UP THROUGH ROOF RETURN /EXHAUST /RELIEF DUCT UP RETURN /EXHAUST /RELIEF DUCT DOWN RETURN /EXHAUST /RELIEF DUCT UP THROUGH ROOF MANUAL VOLUME DAMPER MOTORIZED DAMPER FIRE DAMPER W /ACCESS PANEL FIRE /SMOKE DAMPER W /ACCESS PANEL SMOKE DAMPER W /ACCESS PANEL DUCT RISE (OR DROP) EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED EXISTING DUCTWORK TO BE REMOVED SUPPLY AIR TERMINAL RETURN /TRANSFER AIR TERMINAL EXHAUST AIR TERMINAL VAV BOX ACCESS PANEL THERMOSTAT TEMPERATURE SENSOR SMOKE DETECTOR LONG RADIUS ELBOW SHORT RADIUS ELBOW WITH VANES 1 2/1 2 1 2/1 2 X 12/12 ✓x; 1 2/1 2 1 2/1 2 12/12 f n 12/12 f f D 12/12 f f SD FSD 12/12 I f 1 2/1 2 L 1 2/1 2 1 2/1 2 i TYPE - NECK SIZE AIRFLOW (CFM) TYPE - NECK SIZE AIRFLOW (CFM) TYPE - NECK SIZE AIRFLOW (CFM) X 0 SD A -10 300 B -22/22 300 C -10/10 150 BRANCH DUCT W/ EXTERNAL INSULATION INSULATED FLEXIBLE DUCT MAX. 5' -0" LONG ONE DRAW BAND FOR INNER LINER AND ONE DRAW BAND FOR OUTSIDE VAPOR BARRIER - TYPICAL © EACH FLEX -DUCT CONNECTION MAIN DUCT BRANCH MANUAL VOLUME DAMPER 4" RIGID DUCT EXTENSION ATTACHED TO DIFFUSER NECK N_ CEILING' DIFFUSER TYP. DIFFUSER/DUCT CONNECTIONS 2 NO SCALE LAY -IN DIFFUSER GENERAL NOTES 1 0• A. THE GENERAL CONTRACTOR SHALL COORDINATE TEST & BALANCE WITH NEBB OR AABC CERTIFIED BALANCE CONTRACTOR. TEST & BALANCE OF ENTIRE TENANT HVAC SYSTEM SHALL BE PERFORMED, INCLUDING BUT NOT LIMITED TO: SUPPLY AIR, RETURN AIR, OUTSIDE AIR, CHILLED WATER, AND HOT WATER. VERIFY WITH BEST BUY MOBILE CONSTRUCTION MANAGER AND /OR LANDLORD REPRESENTATIVE. B. SUBMIT COPIES OF TEST & BALANCE REPORT TO LANDLORD, OWNER & ENGINEER. C. CONTRACTOR SHALL COMPLETELY REMOVE FROM THE PREMISES ALL EQUIPMENT, PIPING, DUCTWORK, CONTROLS, CONTROL WIRING, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. D. REFER TO ARCHITECTURAL SHEETS FOR CEILING HEIGHTS. E. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING EQUIPMENT CONDITIONS PRIOR TO BID. F. EXISTING DUCT LAYOUT FOR REFERENCE ONLY. CONTRACTOR TO VERIFY EXACT SIZES AND LAYOUT. G. MECHANICAL INSTALLATION & SERVICE WORK SHALL BE COMPLETE BY SUBSTANTIAL COMPLETION. CONDUCT TEST & BALANCE DURING TIME OF FIXTURING. G.C. SHALL COORDINATE COMPLETION OF WORK THAT HAS IMPACT ON TEST & BALANCE RESULTS (I.E. WALLS; DROP CEILING; DOORS; ETC.) H. ALL NEW DUCTWORK TO BE SHEET METAL - SEE SPECIFICATION FOR ADDITIONAL INFORMATION. I. SLEEVE AND SEAL ALL FLOOR PENETRATIONS LIQUID TIGHT AND INSTALL WATERPROOF FLOOR MEMBRANE -ALL PLUMBING AREAS. EXHAUST FAN SCHEDULE A DIFFUSE EF TYPE UNIT TAG EF -1 C AREA SERVED TOILET ROOM ITEM MANUFACTURER EXISTING SUPPLY MODEL NUMBER EXISTING DESCRIPTION DRIVE (BELT, DIRECT) EXISTING LAY -IN FAN DATA LAY -IN CFM 100 EXISTING ESP EXISTING EXISTING RPM EXISTING EXISTING MOTOR RPM - EXISTING ELECTRICAL HP - EXISTING V-PH-CY EXISTING REMARKS STARTER EXISTING EXISTING SUPPLY AIR DIFFUSER TO BE CLEANED AND RELOCATED AS SHOWN. DISCONNECT EXISTING HP WEIGHT (LBS) EXISTING REMARKS VERIFY INTERLOCK W/ TOILET ROOM LIGHTS. REFER TO KEYNOTE #4 FOR RE- FURBISHING GRILLE, REGISTE A DIFFUSE Ank TYPE A B C D E ITEM SUPPLY SUPPLY SUPPLY RETURN RETURN DESCRIPTION LAY -IN LAY -IN LAY -IN LAY -IN LAY -IN MANUFACTURER TITUS EXISTING EXISTING TITUS EXISTING MODEL NUMBER TMSA EXISTING EXISTING 5OF EXISTING SIZE 24" X 24" EXISTING EXISTING 24" X 24" EXISTING REMARKS ADJUSTABLE STD. WHITE FINISH EXISTING SUPPLY AIR DIFFUSER TO BE CLEANED AND REUSED. EXISTING SUPPLY AIR DIFFUSER TO BE CLEANED AND RELOCATED AS SHOWN. STD. WHITE FINISH EXISTING RETURN AIR GRILLE TO BE CLEANED AND REUSED. HVAC PLAN } 114"=1'-O" KEY NOTES 1O EXISTING ROOF TOP UNIT (RTU) TO REMAIN. INCLUDING MAIN DUCTWORK, INSULATION, HANGER ASSEMBLIES, ETC. MECHANICAL CONTRACTOR SHALL CHECK, TEST, AND SERVICE UNIT AS REQUIRED, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARING, COILS, DAMPERS, DAMPER OPERATORS, AND MOTORS TO ASSURE UNIT IS OPERATING AT OR NEAR ORIGINAL DESIGN CONDITIONS. PROVIDE DOCUMENTATION OF SERVICES PERFORMED TO BBM CPM. O RELOCATE EXISTING THERMOSTAT FOR RTU CONTROL TO LOCATION SHOWN MOUNTED AT 4' -0" A.F.F. CONFIRM OPERATION OF EXISTING THERMOSTAT PRIOR TO REUSE. O3 CONFIRM OPERATION OF EXISTING DUCT - MOUNTED SMOKE DETECTOR. IF NOT EXISTING, INSTALL DUCT SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR IN RETURN MAIN DUCT. DETECTOR SHALL SHUT DOWN HVAC UNIT UPON DETECTION OF SMOKE. O4 SERVICE AND CLEAN EXISTING EXHAUST FAN AND ASSOCIATED DUCTWORK TO REMAIN. REPLACE AND REPAIR UNIT COMPONENTS AS REQUIRED TO MAKE UNIT FULLY FUNCTIONAL, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARINGS, DAMPERS, MOTORS, OPERATING AND SAFETY CONTROLS. FLEX DUCT 5' -0" MAX LENGTH. (TYPICAL FOR ALL) INSTALL NEW SPIN -IN TAKE OFF IN EXISTING SUPPLY AIR DUCTWORK. PROVIDE MANUAL VOLUME DAMPER. • EXTEND NEW SUPPLY AIR RUN -OUT AS REQUIRED FOR NEW DIFFUSER LOCATION. VERIFY SIZE OF EXISTING RUN -OUT IN FIELD. O CONTRACTOR TO VERIFY, PRIOR TO BID, IF EXISTING RUN -OUT HAS MANUAL VOLUME DAMPER - PROVIDE NEW IF NOT EXISTING. TYPICAL OF ALL SUPPLY AIR TAKE -OFFS TO BE RE -USED. Og RETURN AIR GRILLE CONNECTION SHALL BE GALV. SHEET DUCT. FLEX DUCT IS NOT ACCEPTABLE (TYPICAL). a CLEAN EXISTING SUPPLY DUCT TO REMAIN. SEE SPECIFICATION FOR CLEANING HVAC SYSTEM. 11 CLEAN EXISTING RETURN DUCT TO REMAIN. SEE SPECIFICATION FOR CLEANING HVAC SYSTEM. 12 CLEAN AND REUSE (RELOCATE IF SHOWN) THE EXISTING SUPPLY AIR DIFFUSER. CONTRACTOR SHALL VERIFY DIFFUSER IS IN GOOD WORKING CONDITION AND REBALANCE EXISTING DIFFUSER TO THE CFM INDICATED. CONTRACTOR SHALL REPLACE ANY DAMAGED DIFFUSERS TO ENSURE PROPER AIR FLOWS - NEW DIFFUSER SHALL MATCH EXISTING DIFFUSERS. 13 CLEAN AND REUSE EXISTING RETURN AIR GRILLES. CONTRACTOR SHALL VERIFY GRILLES ARE IN GOOD WORKING CONDITION AND REPLACE ANY DAMAGED RETURN AIR GRILLES AS NECESSARY. CONTRACTOR SHALL MATCH EXISTING RETURN AIR GRILLES IF EXISTING GRILLES NEED TO BE REPLACED. 14 RELOCATE FIRE SPRINKLER HEADS AS REQUIRED FOR NEW LIGHTS, DIFFUSERS, WALLS AND CEILINGS. PLAN SHALL BE SUBMITTED BY A LANDLORD APPROVED FIRE SPRINKLER CONTRACTOR (IF NECESSARY). SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER O.A.D.B. O.A.W.B IADB GAINS SOLAR LOAD 85 65 75 DEG F DEG F DEG F ROOF LOAD GLASS LOAD WALL LOAD LIGHTS PEOPLE PEOPLE (SENS) PEOPLE (LAT) INFILTRATION (SENS) INFILTRATION (LAT) MISCELLANEOUS VENTILATION (SENS) VENTILATION (LAT) SUPPLY FAN LOAD SENS. LOAD TOTAL LOAD TOTAL CFM 2247 6882 392 276 7642 17 3527 3400 21 1 - 203 8199 2477 - 2708 2224 34076 34565 2000 BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H WINTER OADB 23 IADB 70 DEG F DEG F LOSS 4842 3007 1988 BTU H BTU H BTU H 1049 BTUH 13905 BTUH TOTAL 24791 BTUH VENT. 280 CFM RECtivtu. CITY OF TUKkAilLA MAY 3 0 2012 PERMIT CENTER OUTSIDE AIR CALCULATION OUTSIDE AIR CALCULATION BASED ON THE 2009 INTERNATIONAL MECHANICAL CODE: AREA #1 - SALES 0.12 CFM /SQFT. X 938 SQ. FT. = 7.5 CFM / PERSON X 15 PEOPLE = AREA #2 - STORAGE 0.12 CFM /SQFT. X 397 SQ. FT. = MINIMUM VENTILATION REQUIRED: MINIMUM VENTILATION SUPPLIED: NET SQ. FOOTAGE: 938 113 113 VENTILATION: 226 CFM NET SQ. FOOTAGE: 397 VENTILATION: 48 CFM 274 CFM 280 CFM 0412755 -139 DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: MJI CHECKED BY: GMS r T ZF� .W O 0 ow"; AD V 03 DD Z" E Z: :N v WN vv� ttOJ = 3N0 00)ZO -M ZNIal?. w SQ. FT. CALCS RETAIL 1,170 SF TOTAL: 1,682 SF ter: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE Fits ### Ix 0 W Cr < woo C I-- _ (,!) W a0 O W to l— =OM, Z O ZW0— 1-010 D Q N Y 0CL 1`0 V) V) � H PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE n n 0 0 n SCALE: AS NOTED HVAC PLAN EXISTING TU SCHEDULE RTU UNIT TAG RTU -1 AREA SERVED - MANUFACTURER YORK MODEL NUMBER ZFO60 TYPE PACKAGE MIN OUTSIDE AIR CFM 280 SUPPLY FAN CFM 2000 ESP .50 TSP_ .75 RPM EXISTING HP EXISTING BHP EXISTING TYPE EXISTING CLASS (I, II, III, IV) EXISTING FILTERS TYPE THROWAWAY DEPTH 2" EFFICIENCY % 30% MEAN APD .14 GAS HEAT EXCHANGER CFM 2000 FPM EXISTING EAT /LAT 63.2/80.0 INPUT MBH 125 APD EXISTING CONTROL STEPS 1 DX COOLING COIL CFM 2000 EAT DB /WB 77.3/65.0 LAT DB /WB 60.2/59.0 SENSIBLE /TOTAL MBH 36.4/36.9 REFRIGERANT TYPE R -410A SPLIT - NUMBER OF CIRCUITS 1 REFR SUCTION TEMP - COMPRESSOR TYPE SCROLL QUANTITY 1 UNLOADING % 0 -100% ECONOMIZER EXISTING ELECTRICAL MCA EXISTING V -PH -CY EXISTING STARTER EXISTING DISCONNECT EXISTING OPERATING WEIGHT (LBS) EXISTING REMARKS EXISTING ROOFTOP UNIT TO REMAIN - SEE KEYNOTE #1 FOR REFURBISHING REQUIREMENTS. KEY NOTES 1O EXISTING ROOF TOP UNIT (RTU) TO REMAIN. INCLUDING MAIN DUCTWORK, INSULATION, HANGER ASSEMBLIES, ETC. MECHANICAL CONTRACTOR SHALL CHECK, TEST, AND SERVICE UNIT AS REQUIRED, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARING, COILS, DAMPERS, DAMPER OPERATORS, AND MOTORS TO ASSURE UNIT IS OPERATING AT OR NEAR ORIGINAL DESIGN CONDITIONS. PROVIDE DOCUMENTATION OF SERVICES PERFORMED TO BBM CPM. O RELOCATE EXISTING THERMOSTAT FOR RTU CONTROL TO LOCATION SHOWN MOUNTED AT 4' -0" A.F.F. CONFIRM OPERATION OF EXISTING THERMOSTAT PRIOR TO REUSE. O3 CONFIRM OPERATION OF EXISTING DUCT - MOUNTED SMOKE DETECTOR. IF NOT EXISTING, INSTALL DUCT SMOKE DETECTOR FURNISHED BY ELECTRICAL CONTRACTOR IN RETURN MAIN DUCT. DETECTOR SHALL SHUT DOWN HVAC UNIT UPON DETECTION OF SMOKE. O4 SERVICE AND CLEAN EXISTING EXHAUST FAN AND ASSOCIATED DUCTWORK TO REMAIN. REPLACE AND REPAIR UNIT COMPONENTS AS REQUIRED TO MAKE UNIT FULLY FUNCTIONAL, INCLUDING BUT NOT LIMITED TO: FANS, BELTS, BEARINGS, DAMPERS, MOTORS, OPERATING AND SAFETY CONTROLS. FLEX DUCT 5' -0" MAX LENGTH. (TYPICAL FOR ALL) INSTALL NEW SPIN -IN TAKE OFF IN EXISTING SUPPLY AIR DUCTWORK. PROVIDE MANUAL VOLUME DAMPER. • EXTEND NEW SUPPLY AIR RUN -OUT AS REQUIRED FOR NEW DIFFUSER LOCATION. VERIFY SIZE OF EXISTING RUN -OUT IN FIELD. O CONTRACTOR TO VERIFY, PRIOR TO BID, IF EXISTING RUN -OUT HAS MANUAL VOLUME DAMPER - PROVIDE NEW IF NOT EXISTING. TYPICAL OF ALL SUPPLY AIR TAKE -OFFS TO BE RE -USED. Og RETURN AIR GRILLE CONNECTION SHALL BE GALV. SHEET DUCT. FLEX DUCT IS NOT ACCEPTABLE (TYPICAL). a CLEAN EXISTING SUPPLY DUCT TO REMAIN. SEE SPECIFICATION FOR CLEANING HVAC SYSTEM. 11 CLEAN EXISTING RETURN DUCT TO REMAIN. SEE SPECIFICATION FOR CLEANING HVAC SYSTEM. 12 CLEAN AND REUSE (RELOCATE IF SHOWN) THE EXISTING SUPPLY AIR DIFFUSER. CONTRACTOR SHALL VERIFY DIFFUSER IS IN GOOD WORKING CONDITION AND REBALANCE EXISTING DIFFUSER TO THE CFM INDICATED. CONTRACTOR SHALL REPLACE ANY DAMAGED DIFFUSERS TO ENSURE PROPER AIR FLOWS - NEW DIFFUSER SHALL MATCH EXISTING DIFFUSERS. 13 CLEAN AND REUSE EXISTING RETURN AIR GRILLES. CONTRACTOR SHALL VERIFY GRILLES ARE IN GOOD WORKING CONDITION AND REPLACE ANY DAMAGED RETURN AIR GRILLES AS NECESSARY. CONTRACTOR SHALL MATCH EXISTING RETURN AIR GRILLES IF EXISTING GRILLES NEED TO BE REPLACED. 14 RELOCATE FIRE SPRINKLER HEADS AS REQUIRED FOR NEW LIGHTS, DIFFUSERS, WALLS AND CEILINGS. PLAN SHALL BE SUBMITTED BY A LANDLORD APPROVED FIRE SPRINKLER CONTRACTOR (IF NECESSARY). SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER O.A.D.B. O.A.W.B IADB GAINS SOLAR LOAD 85 65 75 DEG F DEG F DEG F ROOF LOAD GLASS LOAD WALL LOAD LIGHTS PEOPLE PEOPLE (SENS) PEOPLE (LAT) INFILTRATION (SENS) INFILTRATION (LAT) MISCELLANEOUS VENTILATION (SENS) VENTILATION (LAT) SUPPLY FAN LOAD SENS. LOAD TOTAL LOAD TOTAL CFM 2247 6882 392 276 7642 17 3527 3400 21 1 - 203 8199 2477 - 2708 2224 34076 34565 2000 BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H BTU H WINTER OADB 23 IADB 70 DEG F DEG F LOSS 4842 3007 1988 BTU H BTU H BTU H 1049 BTUH 13905 BTUH TOTAL 24791 BTUH VENT. 280 CFM RECtivtu. CITY OF TUKkAilLA MAY 3 0 2012 PERMIT CENTER OUTSIDE AIR CALCULATION OUTSIDE AIR CALCULATION BASED ON THE 2009 INTERNATIONAL MECHANICAL CODE: AREA #1 - SALES 0.12 CFM /SQFT. X 938 SQ. FT. = 7.5 CFM / PERSON X 15 PEOPLE = AREA #2 - STORAGE 0.12 CFM /SQFT. X 397 SQ. FT. = MINIMUM VENTILATION REQUIRED: MINIMUM VENTILATION SUPPLIED: NET SQ. FOOTAGE: 938 113 113 VENTILATION: 226 CFM NET SQ. FOOTAGE: 397 VENTILATION: 48 CFM 274 CFM 280 CFM 0412755 -139 DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: MJI CHECKED BY: GMS r T ZF� .W O 0 ow"; AD V 03 DD Z" E Z: :N v WN vv� ttOJ = 3N0 00)ZO -M ZNIal?. w SQ. FT. CALCS RETAIL 1,170 SF TOTAL: 1,682 SF ter: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE Fits ### Ix 0 W Cr < woo C I-- _ (,!) W a0 O W to l— =OM, Z O ZW0— 1-010 D Q N Y 0CL 1`0 V) V) � H PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE n n 0 0 n SCALE: AS NOTED HVAC PLAN ABBREVIATIONS AFF ABOVE FINISHED FLOOR ID INSIDE DIAMETER AMP AMPERE (AMP, AMPS) INV INVERT AP ACCESS PANEL KW KILOWATT BTU BRITISH THERMAL UNIT LAT LEAVING AIR TEMPERATURE CBV CIRCUIT BALANCING VALVE LBS POUNDS CFH CUBIC FEET PER HOUR LWB LEAVING WET BULB CFM CUBIC FEET PER MINUTE LWT LEAVING WATER TEMPERATURE CHW CIRCULATING HOT WATER MA MIXED AIR CHWR CHILLED WATER RETURN MAX MAXIMUM CHWS CHILLED WATER SUPPLY MBH THOUSAND BTU'S /HR CLG CEILING MIN MINIMUM CO CLEANOUT MISC MISCELLANEOUS CR CONDENSATE RETURN NA NOT APPLICABLE CW COLD WATER NC NOISE CRITERIA DB DECIBEL NIC NOT IN CONTRACT DEMO DEMOLITION NTS NOT TO SCALE DIA DIAMETER OA OUTSIDE AIR DIFF DIFFUSER OBD OPPOSED BLADE DAMPER DWG DRAWING PH PHASE (ELECTRICAL) DX DIRECT EXPANSION PVC POLYVINYL CHLORIDE EAT ENTERING AIR TEMPERATURE RA RETURN AIR ELEC ELECTRICAL REC RECESSED ELEV ELEVATION REL RELIEF EMS ENERGY MANAGEMENT SYSTEM RH RELATIVE HUMIDITY ESP EXTERNAL STATIC PRESSURE RM ROOM EWB ENTERING WET BULB RPM REVOLUTIONS PER MINUTE EWT ENTERING WATER TEMPERATURE SA SUPPLY AIR EXH EXHAUST SAN SANITARY EXIST EXISTING SD SMOKE DAMPER F FAHRENHEIT SF SQUARE FEET FSD COMBINATION FIRE /SMOKE DAMPER SP STATIC PRESSURE FCO FLOOR CLEANOUT SPEC SPECIFICATION FD FIRE DAMPER STD STANDARD FD FLOOR DRAIN TD TEMPERATURE DIFFERENCE FFE FINISHED FLOOR ELEVATION TSP TOTAL STATIC PRESSURE FLR FLOOR TIP TYPICAL FPM FEET PER MINUTE V VOLTS FT FOOT OR FEET VFD VARIABLE FREQUENCY DRIVE GA GAGE OR GAUGE VSD VARIABLE SPEED DRIVE GAL GALLONS VOL VOLUME GC GENERAL CONTRACTOR VTR VENT THROUGH ROOF GPH GALLONS PER HOUR W WATTS HP HORSEPOWER W/ WITH HT HEIGHT W/O WITHOUT HVAC HEATING, VENTILATING, AIR CONDITIONING WC WATER CLOSET HW HOT WATER WCO WALL CLEANOUT HZ HERTZ WT WEIGHT EQUIPMENT TAGS ACCU AIR COOLED CONDENSING UNIT FCU FAN COIL UNIT AHU AIR HANDLING UNIT IH INTAKE HOOD CP CIRCULATING PUMP MAU MAKE —UP AIR UNIT DHC DUCT HEATING COIL RF RETURN FAN EF EXHAUST FAN RH RELIEF HOOD EUH ELECTRIC UNIT HEATER RTU ROOFTOP UNIT EWC ELECTRIC WATER COOLER VAV VARIABLE AIR VOLUME BOX EWH ELECTRIC WATER HEATER PLUMBING LINETYPE LEGEND COLD WATER — DOMESTIC DOMESTIC COLD WATER (BELOW FLOOR /GRADE) — — — DOMESTIC COLD WATER — — (EXISTING) WATER — — DOMESTIC HOT WATER — — — — — — — — — — DOMESTIC HOT (EXISTING) GAS G GAS G (ON ROOF) GAS G (EXISTING) — — G GAS (EXISTING ON ROOF) SANITARY SEWER (ABOVE FLOOR /GRADE) SANITARY SEWER FLOOR ........ (BELOW /GRADE) SANITARY SEWER (EXISTING) VENT VENT (UNDERFLOOR /GRADE) VENT (EXISTING) PLUMBING SYMBOL LEGEND FLOOR DRAIN El BALL VALVE L1 GATE VALVE iI CHECK VALVE Dal DRAIN VALVE 1 2 —WAY VALVE VII SOLENOID VALVE A MOTORIZED VALVE L3 —WAY VALVE THERMOSTATIC/ u::u PRESSURE BALANCE MIXING VALVE X II 4 g C M) IJ 11 l© ANCHOR a REDUCER PIPE FLANGE ® FLOW ARROW AIR CHAMBER o EXPANSION JOINT WATER HAMMER n FLEXIBLE ARRESTER N CONNECTOR EXPANSION TANK T TEST PLUG WATER METER LJ VACUUM RELIEF VALVE THERMOMETER 4 AQUASTAT PRESSURE GAGE IA REGULATOR STRAINER 0 PIPE DOWN PUMP 0 PIPE UP — T? PT RAP PRIMING PLUMBING 0 TEE DOWN VALVE FIXTURE TAG PRESSURE Ili UNION RELIEF VALVE ® RECEPTOR TAG III BUTTERFLY VALVE ►4 BFP BACKFLOW n PIPE CAP PREVENTER >1 GLOBE VALVE CIRCUIT s PIPE BREAK BALANCING VALVE MISC. SYMBOL LEGEND — 1 XXX EQUIPMENT TAG S CONNECTION TO EXISTING 1 AREVISION TRIANGLE KEY NOTE DOMESTIC WATER RISER 3 NO SCALE T SANITARY WASTE & VENT RISER CrA.-- NO SCALE 0 P3 CO PLUMBING PLAN 1/4"=V-0" KEY NOTES O EXTEND AND CONNECT NEW 2" SANITARY SEWER TO EXISTING 3" (MIN) SANITARY SEWER PIPING SERVING EXISTING TOILET ROOM. FIELD VERIFY EXACT LOCATION, SIZE, FLOW DIRECTION, AND INVERT ELEVATION OF CONNECTION POINT PRIOR TO ROUGH —IN OF NEW SANITARY SEWER. PROVIDE FCO AT POINT OF CONNECTION TO EXISTING. EXTEND AND CONNECT NEW CW PIPING OF SIZE SHOWN TO EXISTING 3/4" (MIN) CW PIPING SERVING EXISTING TOILET ROOM. FIELD VERIFY EXACT LOCATION OF CW PIPING PRIOR TO ROUGH —IN. PROVIDE SHUTOFF VALVE AT POINT OF CONNECTION TO EXISTING. O3 EXTEND NEW 1 -1 /2" VENT AND CONNECT TO EXITING MIN. 2" VENT PIPING SERVING EXISTING TOILET ROOM. FIELD VERIFY EXACT LOCATION OF EXISTING VENT PIPING PRIOR TO ROUGH —IN. O SERVICE AND CLEAN EXISTING WATER CLOSET TO REMAIN. O5 SERVICE AND CLEAN EXISTING LAVATORY TO REMAIN. O SERVICE AND CLEAN EXISTING WATER HEATER TO REMAIN. VERIFY OPERATION PRIOR TO REUSE — PROVIDE NEW IF REQUIRED. BATHROOM COMPONENT SCHEDULE Item Model # Exist. To Remain New (Add /Replace) Notes: Toilet — 1 — -- Toilet Seat — 1 — -- Sink — 1 — -- Faucet — 1 — -- Pipe Wrap — 1 — -- Water Heater — 1 — -- Water Cooler ELKAY MODEL LZSTL8C — 1 SEE SCHEDULE EXISTING FIXTURE NOTES: Toilet: Ensure that the fixture is fully functioning. Clean completely. Notify the Construction Project Manager if there are any cracks or leaks. Ensure that seat is existing, complete, level, clean, and is properly attached. Sink: Ensure that the fixture is fully functioning. Fixture must be securely attached to the wall. Clean all components. Faucet: Ensure that faucet is fully functioning. Clean all components. Faucet to be securely attached to fixture. Ensure there are no leaks from faucet. Pipewrap: Ensure that there pewrap covering exposed F�'q AR R�'j�T�TF RFQ Ro�'�N0 is complete piping. REGEfvt;u. CITY OF TUKWILA MAY 3 0 2012 °PRMIT ( MTFR PLUMBING FIXTURE SCHEDULE (F#)(p#) EXISTING INSTANTANEOUS WATER HEATER SCHEDULE FIXTURE TYPE MANUFACTURER TYPE & MODEL NO. UNIT NO. MANUFACTURER MODEL KW OUTPUT (GPM) TEMP. RISE 'F VOLTAGE REMARKS IWH -1 EXISTING DHC -3 -1 3.0 EXIST. EXIST. EXISTING EXISTING TO REMAIN PLUMBING FIXTURE SCHEDULE (F#)(p#) FIXTURE NO. FIXTURE TYPE MANUFACTURER TYPE & MODEL NO. TRIM NO. SUPPORT PIPE SIZES REMARKS TRAP WASTE VENT CW HW P1 WATER CLOSET EXISTING EXISTING EXISTING FLOOR MOUNT 4" 2" 1/2" — EXISTING TO REMAIN P2 LAVATORY EXISTING EXISTING EXISTING WALL HUNG 1 -1 2 / 2" 1 -1 /2" 1 /2" 1 /2" EXISTING TO REMAIN P3 HI —LO WATER COOLER ELKAY BARRIER —FREE LZSTL8C — — WALL MOUNT 1 -1 /2" 2" 1 -1 /2" 1 /2" _ UNIT TO BE INSTALLED WITH ACCESSORY APRON LKAPREZL FOR ADA COMPLIANCE IF MTD. ON EXPOSED WALL 0412755 -139 MI DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: MJI CHECKED BY: GMS -ZS -� Z 000N.a) E tow" V w" AcoM i > D ep) M D aD Z�y Z N._ WN .y N Noy WN0 ZW.j OQ)ZO 1 Z C%1 W SQ. FP. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF war: 1.0 LARGE colwcET DATE: 04 -28 -1 1 DIME NUMIXOt # ## loo co Zr W 00 U O) CX CI Wml—Q W 4k( U �F►�! ) = W C3 I — C.) LO DQNY 0Qr= PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE n n A n n SCALE: AS NOTED PLUMBING PLAN M 15010 GENERAL PROVISIONS A. FURNISHING LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED AS SHOWN ON THE DRAWINGS AND SPECIFIED IN DIVISION 15. B. ALL WORK SHALL BE COMPLETE AND SHALL BE LEFT IN OPERATING CONDITION. C. INCLUDE ALL PARTS AND LABOR WHICH ARE INCIDENTAL AND NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. D. ARRANGE WITH APPROPRIATE UTILITY COMPANIES TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL FEES AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. E. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTIONS WITH THIS DIVISION'S WORK. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. F. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS SPECIFICATIONS. G. PROVIDE THE OWNER WITH A CERTIFICATE OF FINAL INSPECTION AND APPROVAL BY ENFORCEMENT AUTHORITIES. H. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON- COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER. I. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. FURNISH: TO OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOB SITE IN NEW CONDITION READY FOR INSTALLATION, UNLOAD AND UNPACK, AND GUARANTEE. J. INSTALL: TO RECEIVE AT THE JOB SITE, STORE, ASSEMBLE, ERECT, SET IN PLACE, ANCHOR, APPLY, FINISH, PROTECT, CLEAN, TEST, START -UP, AND MAKE READY FOR OWNER'S USE. K. PROVIDE: TO FURNISH AND INSTALL. L. CONTRACTOR IS RESPONSIBLE FOR DIMENSIONAL DIFFERENCES, WEIGHTS, ELECTRICAL REQUIREMENTS AND ANY OTHER RESULTING CHANGES, WHEN USING EQUIPMENT OTHER THAN THAT SCHEDULED ON THE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL COSTS INCURRED AS A RESULT OF SUBSTITUTIONS. M. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIOR TO BIDDING. N. MECHANICAL EQUIPMENT AND SYSTEMS SHOWN ON THE DRAWINGS AS EXISTING, HAVE BEEN BASED ON EXISTING PLANS, AND MAY NOT BE INSTALLED AS ORIGINALLY SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE, LOCATION AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING A BID. 0. CONSULT THE DRAWINGS AND SPECIFICATIONS OF DIVISION 16 AND OTHER TRADES FOR CORRELATING INFORMATION AND LAYOUT WORK SO THAT IT WILL COORDINATE WITH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E., FINISHED CEILING HEIGHTS, FOOTINGS AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. P. DRAWINGS MAY NOT SHOW EVERY RISE AND OFFSET REQUIRED FOR THE WORK. INSTALL PIPING AND DUCTWORK TO ACCOMMODATE THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES, WITH ALL REQUIRED OFFSETS AND WITHOUT EXTRA COST TO THE OWNER. Q. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT, FURNISHED BY OTHERS FROM THE PERSON FURNISHING THE EQUIPMENT. R. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK AS EVIDENCED BY ISSUANCE OF THE FINAL CERTIFICATE BY THE ARCHITECT. S. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. T. MAGNETIC STARTERS, DISCONNECTS, AND POWER WIRING PROVIDED BY THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE SPECIFIED. U. CONTROL AND INTERLOCK WIRING PROVIDED BY THE MECHANICAL CONTRACTOR, UNLESS OTHERWISE SPECIFIED. V. PROVIDE ONLY PRODUCTS FROM MANUFACTURERS WITH LOCAL REPRESENTATION THAT CAN PROVIDE COMPLETE COVERAGE, PARTS AND LABOR, FOR REPLACEMENT AND SERVICE OF THEIR PRODUCTS. PROVIDE ONLY EQUIPMENT THAT WILL FIT IN THE SPACE AVAILABLE AND BE COMPLETELY SERVICEABLE. BRING AND CONFLICTS TO THE ENGINEER'S ATTENTION PRIOR TO ORDERING THE EQUIPMENT. W. COORDINATE/SCHEDULE ALL WORK WITH THE OWNER TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE. X. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. Y. NO FIRE SPRINKLER OR FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE SPRINKLER OR FIRE ALARM SYSTEM IS OPERATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE OWNER. Z. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE. PROTECT EQUIPMENT AND MATERIAL FROM DAMAGE, DIRT AND THE WEATHER. AA. PROVIDE THE HIGHEST QUALITY WORKMANSHIP AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS AND CURRENT STANDARDS. BB. THE ENGINEER RESERVES THE RIGHT TO REJECT MATERIAL OR WORKMANSHIP NOT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, BEFORE OR AFTER INSTALLATION. CC. ALL PIPING AND DUCTWORK SHALL BE RUN IN THE MOST DIRECT AND STRAIGHT MANNER POSSIBLE MAINTAINING PROPER GRADING. DD. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT MOST PIPING AND DUCTWORK BE CONCEALED WHERE EXPOSED, RUN AS CLOSE TO CEILING AND /OR WALL AS POSSIBLE PARALLEL WITH ADJACENT STRUCTURAL OR ARCHITECTURAL ELEMENTS. EE. DO NOT INSTALL PIPING OR DUCTWORK IN ANY SWITCHGEAR, TRANSFORMER, ELEVATOR EQUIPMENT, TELEPHONE, OR ELECTRICAL EQUIPMENT ROOM, UNLESS IT IS A BRANCH SERVING THAT ROOM. FF. DO NOT INSTALL PIPING OR DUCTWORK ABOVE SWITCHBOARDS, PANELBOARDS, CONTROL PANELS, MOTOR CONTROL CENTERS, ETC. GG. ARRANGE WORK TO FACILITATE MAINTENANCE, REPAIR OR REPLACEMENT OF EQUIPMENT. PROVIDE ACCESS FOR DEVICES THAT REQUIRE MAINTENANCE. FOR CONCEALED DEVICES, VERIFY THAT ACCESS PANELS ARE PROPERLY LOCATED AND LABELED. HH. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH T HE MANUFACTURER'S WRITTEN INSTRUCTION. II. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR. OBTAIN SPECIAL PERMISSION FROM THE STRUCTURAL ENGINEER BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH A MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKERS EXPERIENCE, SKILLED, AND LICENSED FOR THE PARTICULAR TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. JJ. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF MECHANICAL EQUIPMENT AND DEVICES. I(K. DRILL ALL HOLES IN MASONRY WITH ROTARY DRILL. IMPACT TOOLS ARE NOT ALLOWED. CORE DRILL ALL HOLES IN MASONRY AND CONCRETE FOR MECHANICAL PENETRATIONS. PROVIDE AND DISPOSE OF ALL WATER REQUIRED FOR CORE DRILLING. COORDINATE WITH OTHER TRADES TO PREVENT DAMAGE FROM WATER. LL. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. MM. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF WORK, WITH NEW TILE. NN. REFINISH ALL MECHANICAL EQUIPMENT DAMAGED DURING SHIPPING AND /OR INSTALLATION TO ITS ORIGINAL CONDITION. REMOVE ALL RUST; PRIME, AND PAINT PER MANUFACTURE'S RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL. 00. DO NOT USE HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS PROVIDED IN THIS SCOPE OF WORK FOR TEMPORARY HEATING, VENTILATING AND AIR CONDITIONING DURING CONSTRUCTION. PP. PROTECT OPENINGS AND EQUIPMENT FROM OBSTRUCTION, BREAKAGE, MISUSE, DAMAGE OR BLEMISHES. PROTECT MATERIALS AND EQUIPMENT IMMEDIATELY UPON RECEIPT AT THE JOB SITE OR IMMEDIATELY AFTER THEY HAVE BEEN REMOVED FROM THEIR SHIPPING CONTAINERS. UNLESS NOTED OTHERWISE, KEEP THEM CLEAN AND UNDAMAGED UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE OWNER. WHEN A PORTION OF THE BUILDING IS OCCUPIED BY THE OWNER BEFORE SUBSTANTIAL COMPLETION OF THE ENTIRE PROJECT, MAKE ARRANGEMENTS TO TRANSFER RESPONSIBILITY FOR PROTECTION AND HOUSEKEEPING FOR THE OCCUPIED PORTION. QQ. PROTECT PIPE, DUCT AND EQUIPMENT OPENINGS WITH TEMPORARY PLUGS OR CAPS. KEEP OPENINGS COVERED UNTIL PERMANENT OPENINGS WITH TEMPORARY PLUGS OR CAPS. KEEP OPENINGS COVERED UNTIL PERMANENT CONNECTIONS ARE COMPLETE. RR. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO MECHANICAL EQUIPMENT, MATERIALS OR WORK UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE OWNER. KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIAL OR RUBBISH, CAUSED BY HIS EMPLOYEES OR WORK, AT ALL TIMES. REMOVE RUBBISH, TOOLS, SCAFFOLDING, AND SURPLUS MATERIALS FROM AND ABOUT THE BUILDING, AND LEAVE WORK AREAS "BROOM CLEAN° OR ITS EQUIVALENT UPON COMPLETION OF THE WORK. CLEAN MECHANICAL EQUIPMENT AND REMOVE TEMPORARY IDENTIFICATION. SS. IN CASE OF DISPUTE, THE OWNER WILL REMOVE THE RUBBISH AND CHARGE THE COST TO THE CONTRACTOR. TT. BEFORE START -UP, LUBRICATE, CHARGE, AND FILL SYSTEMS AS SPECIFIED AND ACCORDING TO MANUFACTURER'S INSTRUCTIONS. UU. CLEAN, DISINFECT, AND TEST ALL PLUMBING AND PIPING SYSTEMS. W. PERFORM TESTING, ADJUSTING AND BALANCING IN ACCORDANCE WITH THAT SECTION. WW. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES, TO VERIFY PROPER OPERATION, PRIOR TO FINAL FIELD OBSERVATION AND OWNER INSTRUCTIONS. XX. ATTEND PRE - TESTING CONFERENCE AS SCHEDULED BY TESTING, ADJUSTING AND BALANCING CONTRACTOR. YY. PROVIDE ASSISTANCE TO TEST, ADJUSTING AND BALANCING CONTRACTOR BY MAKING ADJUSTMENTS TO SYSTEM AND SYSTEM COMPONENTS REQUIRED FOR ACHIEVING DESIGN PERFORMANCE. ZZ. IF ACCEPTABLE PERFORMANCE OF ANY TEST IS NOT ACHIEVED, MAKE THE NECESSARY CORRECTIONS AND THE TEST SHALL BE REPEATED UNTIL ACCEPTABLE PERFORMANCE IS ACHIEVED. MA. FULLY INSTRUCT THE OWNER'S DESIGNATED PERSONNEL IN THE OPERATION OF EACH MECHANICAL SYSTEM AT THE TIME IT IS PUT INTO SERVICE. PROVIDE INSTRUCTION USING COMPETENT INSTRUCTORS AND FACTORY TRAINED PERSONNEL. BBB. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION OF MAINTENANCE MANUALS. CCC. OBTAIN A WRITTEN STATEMENT FROM THE OWNER THAT HIS DESIGNATED PERSONNEL HAVE BEEN INSTRUCTED. DDD. SUBMIT COMPLETED BOUND OPERATION AND MAINTENANCE MANUALS TO OWNER INCLUDING SHOP DRAWINGS, WARRANTIES, TEST REPORTS, CERTIFICATIONS, TEST AND BALANCE REPORTS, SYSTEM VALIDATION REPORTS AND RECORD DRAWINGS. 15025 DEMOLITION A. FURNISH LABOR, EQUIPMENT, AND MATERIALS REQUIRED FOR CUTTING, DEMOLITION, REMOVAL, PATCHING, AND RESTORATION WORK NECESSARY TO ACCOMPLISH AND COMPLETE ALL DEMOLITION, INCLUDING ANY RELOCATION OF REUSE OF EXISTING MATERIALS, EQUIPMENT, SYSTEMS, AS WELL AS THE DISPOSITION OF SALVAGED MATERIALS OR DEBRIS. B. ACCOMPLISH ALL WORK OF CUTTING, REMOVAL, DEMOLITION, RELOCATION, PATCHING, AND RESTORATION BY USING ONLY MECHANICALS SKILLED IN THE TRADE REQUIRED. PROVIDE FOR THE SAFETY OF THE EXISTING BUILDING AND PERSONNEL, AS WELL AS FOR NEW CONSTRUCTION AS A RESULT OF WORK, PROCEDURES, OPERATIONS OR ACTIVITIES UNDER THIS CONTRACT. C. WHERE THE WORK OF REMOVALS, DEMOLITION, CUTTING AND SIMILAR WORK INVOLVES STRUCTURAL CONSIDER RATIONS, CONSULT WITH STRUCTURAL ENGINEER. EXERCISE EXTREME CARE TO AVOID DAMAGE AND PRESERVE THE SAFETY OF THE STRUCTURE AND OF ALL PERSONNEL. PARTICULAR CARE MUST BE TAKEN WHERE THE DEMOLITION OR REMOVALS OCCUR ADJACENT TO OCCUPIED AREAS. D. UTILIZE COMPETENT AND QUALIFIED TECHNICAL ASSISTANCE TO DEVELOP SAFE METHODS AND TECHNIQUES TO ACCOMPLISH THE WORK, INCLUDING TEMPORARY SHORING AND SUPPORTS, METHODS OF REMOVAL AND OTHER CONSIDERATIONS. DESIGN AND PLACE ALL PERMANENT OR TEMPORARY SUPPORTS TO CARRY ALL LOADS DOWN TO SOUND BEARING. 15081 DUCTWORK INSULATION A. MATERIALS: CONFORM TO MAXIMUM FLAME SPREAD /SMOKE DEVELOPED RATING OF 26 /60 IN ACCORDANCE WITH ASTM E84, NFPA 255 AND UL 723. B. CONFORM TO ASTM STANDARDS FOR "K° VALUE, MOISTURE VAPOR TRANSMISSION, MAXIMUM MOISTURE ABSORPTION, JACKET, INSULATING CEMENT, AND ADHESIVE. C. MANUFACTURER: SCHULLER - MANVILLE 800 SERIES SPIN -GLAS a. GLASS FIBER (FLEXIBLE/RIGID): SCHULLER- MANVILLE 800 SERIES SPIN/GLAS. EQUIVALENT PRODUCTS: CERTAINTEED, KNAUF, OWENS- CORNING. b. GLASS FIBER DUCT LINER, FLEXIBLE: SCHULLER - MANVILLE PERMACOTE LINACOUSTIC STANDARD. EQUIVALENT PRODUCTS: CERTAINTEED, KNAUF, OWENS - CORNING. c. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. D. DRIP PAN BELOW ROOF FANS: FLEXIBLE GLASS FIBER BLANKET - EXTERNAL: 1 -1/2 INCHES THICK E. EXHAUST AND RELIEF AIR DUCTS WITHIN 10 FT. OF EXTERIOR OPENINGS: FLEXIBLE GLASS FIBER BLANKET - EXTERNAL: 1 -1/2 INCHES THICK F. OUTSIDE AIR INTAKE DUCTS: a. FLEXIBLE GLASS FIBER BLANKET - EXTERNAL: 3 INCHES THICK b. RIGID GLASS FIBER - EXTERNAL: 1-1/2 INCHES THICK G. SUPPLY DUCTS - CONCEALED: FLEXIBLE GLASS FIBER BLANKET - EXTERNAL 1 -112 INCHES THICK H. SUPPLY DUCTS - EXPOSED RIGID GLASS FIBER - EXTERNAL: 1 INCH THICK I. TRANSFER DUCTS: FLEXIBLE GLASS FIBER DUCT LINER: Y INCH THICK. 15083 PIPING INSULATION A. CONFORM TO MAXIMUM FLAME SPREAD /SMOKE DEVELOPED RATING OF 25/60 IN ACCORDANCE WITH ASTM E84, NFPA 255 AND UL 723. B. CONFORM TO ASTM STANDARDS FOR "K" VALUE, MOISTURE VAPOR TRANSMISSION, MAXIMUM MOISTURE ABSORPTION, JACKET, INSULATING CEMENT, AND ADHESIVE. C. MANUFACTURER: GLASS FIBER: SCHULLER - MANVILLE, CERTAINTEED, KNAUF, OWENS- CORNING. a. CELLULAR FOAM: ARMSTRONG, HALSTEAD, IMCOA/NOMACO, RUBATEX, ARMAFLEX 2000. D. INSTALL IN ACCORDANCE WITH NAIMA NATIONAL INSULATION STANDARDS. VERIFY THAT PIPING HAS BEEN TESTED BEFORE APPLYING INSULATION MATERIALS. VERIFY THAT SURFACES ARE CLEAN AND DRY, WITH FOREIGN MATERIAL REMOVED. E. CONTINUE INSULATION THROUGH WALLS, SLEEVES, PIPE HANGERS, AND OTHER PIPE PENETRATIONS. FINISH AT SUPPORTS, PROTRUSIONS, AND INTERRUPTIONS. F. BURIED PIPING: PROVIDE FACTORY FABRICATED ASSEMBLY WITH INNER ALL - PURPOSE SERVICE JACKET WITH SELF - SEALING LAP, AND ASPHALT IMPREGNATED OPEN MESH GLASS FABRIC, WITH ONE MIL THICK ALUMINUM FOIL SANDWICHED BETWEEN THREE LAYERS OF BITUMINOUS COMPOUND; OUTER SURFACE FACED WITH A POLYESTER FILM. G. SCHEDULE: INSULATION THICKNESS PER LOCAL CODE OR ASHRAE STANDARD 90.1 -1999, WHICHEVER IS MORE STRINGENT. 15100 PLUMBING PIPING A. SANITARY PIPING: a. CAST IRON PIPE: ASTM A74 SERVICE WEIGHT, FITTINGS: CAST IRON, JOINTS: HUB- AND-SPIGOT, COMPRESSION TYPE WITH NEOPRENE GASKETS OR LEAD AND OAKUM. b. CAST IRON PIPE: CISPI 301, HUBLESS, FITTINGS: CAST IRON, JOINTS: NEOPRENE GASKET AND STAINLESS STEEL CLAMP AND SHIELD ASSEMBLIES. c. ABS PIPE (BELOW GRADE): ASTM D2661, FITTINGS: ABS JOINTS: SOLVENT WELD. d. PVC PIPE (BELOW GRADE): ASTM D2665, FITTINGS: PVC, JOINTS: SOLVENT WELD WITH SOLVENT CEMENT. e. COPPER TUBE (ABOVE GRADE): ASTM B88 TYPE "L ", HARD TEMPER ONLY. EXCEPT THESE MATERIALS SHALL NOT BE USED TO RECEIVE THE WASTES FROM URINALS NOR WASTES FROM WATER CLOSETS IN BATTERY, FITTINGS: CAST BRONZE, OR WROUGHT COPPER, JOINTS: SOLDER, GRADE 50B. B. WATER PIPING: a. COPPER TUBING (BELOW GRADE): ASTM B88, TYPE "K" SOFT COPPER, FITTINGS: CAST COPPER ALLOY OR WROUGHT COPPER AND BRONZE, JOINTS: B CUP SILVER BRAZE. b. COPPER TUBING (ABOVE GRADE): ASTM B88, TYPE "L" HARD DRAWN, FITTINGS: CAST COPPERS ALLOY OR WROUGHT COPPER AND BRONZE, JOINTS: B CUP SILVER BRAZE. C. NATURAL GAS PIPING: a. STEEL PIPE (BELOW GRADE): ASTM A53 SCHEDULE 40 BLACK, FITTINGS: FORGED STEEL WELDING TYPE, JOINTS: WELDED, JACKET POLYETHYLENE JACKET OR DOUBLE LAYER, HALF- LAPPED 10 MIL POLYETHYLENE TAPE. b. STEEL PIPE (ABOVE GRADE): ASTM A53 SCHEDULE 40 BLACK 2 INCH AND SMALLER EXPOSED, FITTINGS: MALLEABLE IRON, JOINTS: THREADED. c. STEEL PIPE (ABOVE GRADE): ASTM A53 SCHEDULE 40 BLACK, 2 INCH AND SMALLER CONCEALED, AND 2 Y INCH AND LARGER, FITTINGS: FORGED STEEL WELDING TYPE, JOINTS: WELDED. D. VERIFY THAT EXCAVATIONS ARE TO REQUIRED GRADE, DRY AND NOT OVER- EXCAVATED. E. PREPARE PIPING CONNECTIONS TO EQUIPMENT WITH FLANGES OR UNIONS. F. PROVIDE NON - CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR METALS. G. INSTALL VENT PIPING PENETRATING ROOFED AREAS TO MAINTAIN INTEGRITY OF ROOF ASSEMBLY. H. WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH PRIMER TO WELDING. I. PROVIDE SUPPORT FOR UTILITY METERS IN ACCORDANCE WITH REQUIREMENTS OF UTILITY COMPANIES. J. PREPARE EXPOSED, UNFINISHED PIPE, FITTINGS, SUPPORTS, AND ACCESSORIES READY FOR FINISH PAINTING. K. PIPE VENTS FROM GAS PRESSURE REDUCING VALVES TO OUTDOORS AND TERMINATE IN WEATHER PROOF HOOD. L. SLEEVE PIPES PASSING THROUGH PARTITIONS, WALLS AND FLOORS. M. USE GROOVED MECHANICAL COUPLINGS AND FASTENERS ONLY IN ACCESSIBLE LOCATIONS. N. PROVIDE UNIONS DOWNSTREAM OF VALVES AND AT EQUIPMENT OR APPARATUS CONNECTIONS. 0. PROVIDE BRASS MALE ADAPTERS EACH SIDE OF VALVES IN COPPER PIPED SYSTEM. SOLDER ADAPTERS TO PIPE. P. ESTABLISH INVERT ELEVATIONS, SLOPES FOR DRAINAGE TO % INCH PER FOOT (SMALLER THAN 3 INCH PIPE), AND 1/8 INCH PER FOOT (3 INCHES AND LARGER) MINIMUM. MAINTAIN GRADIENTS. Q. SLOPE WATER PIPING MINIMUM 0.25 PERCENT AND ARRANGE TO DRAIN AT LOW POINTS. R. PROVIDE NEW SANITARY SEWER SERVICES. BEFORE COMMENCING WORK CHECK INVERT ELEVATIONS REQUIRED FOR SEWER CONNECTIONS, CONFIRM INVERTS AND ENSURE THAT THESE CAN BE PROPERLY CONNECTED WITH SLOPE FOR DRAINAGE AND COVER TO AVOID FREEZING. S. PROVIDE SUPPORT AND EQUIPMENT REQUIRED TO CONTROL EXPANSION AND CONTRACTION OF PIPING. PROVIDE LOOPS, PIPE OFFSETS, AND SWING JOINTS, OR EXPANSION JOINTS WHERE REQUIRED. T. PROVIDE HANGERS (MINIMUM OF 12 GAUGE) IN QUANTITY AND SPACING REQUIRED TO SUFFICIENTLY SUPPORT PIPING. 15110 VALVES & PLUMBING SPECIALTIES A. MANUFACTURERS: a. GATE VALVES (UP TO AND INCLUDING 2"): STOCKHAM MODEL B -105, OR EQUIVALENT BY: i. HAMMOND, KITZ, MILWAUKEE, NIBCO, CRANE. b. BALL VALVES (UP TO AND INCLUDING 21: APOLLO 77- 100/T7 -200 SERIES, OR EQUIVALENT BY: i. HAMMOND, KITZ, MILWAUKEE, NIBCO, WATTS, CRANE. c. SWING CHECK VALVES (UP TO AND INCLUDING 2- 1 /21: STOCKHAM MODEL B -3091B -319, OR EQUIVALENT BY: i. HAMMOND, KITZ, MILWAUKEE, NIBCO, CRANE. d. BALL VALVES (FOR NATURAL GAS): APOLLO 80 -100 SERIES, OR EQUIVALENT BY: i. HAMMOND, KITZ, MILWAUKEE, NIBCO, WATTS. e. TEMP. AND PRESS. RELIEF VALVE (UP TO 80,000 BTU INPUT): WATTS 10L MODEL M7. f. WATER HAMMER ARRESTOR: WATTS SERIES 16. g. BACKFLOW PREVENTER: WATTS 9BD. h. VACUUM BREAKER: WATTS N36 -3/4 ". i. PRESSURE REDUCING VALVE: WATTS SERIES U6. j. ATMOSPHERIC VACUUM BREAKER: WATTS SERIES 288A. k. HOSE AND VACUUM BREAKER: WATTS SERIES 8. I. DIELECTRIC UNION: WATTS SERIES 3000. m. TRAP SEAL PRIMER VALVE: JOSAM 88260, OR EQUIVALENT BY: i. J.R. SMITH, WADE, ZURN B. INSTALL APPROVED POTABLE WATER PROTECTION DEVICES ON PLUMBING LINES WHERE CONTAMINATION OF DOMESTIC WATER MAY OCCUR; JANITOR ROOMS, FIRE SPRINKLER SYSTEMS, PREMISE ISOLATION. C. INSTALL WATER HAMMER ARRESTORS COMPLETE WITH ACCESSIBLE ISOLATION VALVE ON HOT AND COLD WATER SUPPLY PIPING WHERE REQUIRED BY CODE AND PER MANUFACTURER'S RECOMMENDATIONS /REQUIREMENTS. D. INSTALL AIR CHAMBERS ON HOT AND COLD WATER SUPPLY PIPING TO EACH FIXTURE OR GROUP OF FIXTURES (EACH WASHROOM). FABRICATE SAME SIZE AS SUPPLY PIPE OR' INCH MINIMUM, AND MINIMUM 18 INCHES LONG. 15325 SPRINKLER SYSTEMS A. CONTRACTOR SHALL DESIGN AND HYDRAULICALLY CALCULATE THE NEW AND RENOVATION OF EXISTING PIPING SYSTEMS, INCLUDING LOCATION OF ALL VALVES, DEVICES AND SPRINKLER HEADS. DESIGN SPRINKLER SYSTEM PIPING BASED ON HAZARD RATING AS OF THE MOST STRINGENT OF THE REGULATING AGENCIES RESPONSIBLE FOR THIS FACILITY, INCLUDING THE OWNER INSURANCE COMPANY REQUIREMENTS AND THE GOVERNING AUTHORITIES, FM OR AS DETERMINED BY LOCAL REQUIREMENTS. PERFORM WORK IN ACCORDANCE WITH NFPA 13. B. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND HYDRAULIC CALCULATIONS TO AUTHORITY HAVING JURISDICTION, AND OWNER'S INSURANCE UNDERWRITER FOR APPROVAL. SUBMIT PROOF OF APPROVAL TO ARCHITECT/ENGINEER. C. PROVIDE EXTRA SPRINKLERS UNDER PROVISIONS OF NFPA 13. D. PROVIDE SUITABLE WRENCHES FOR EACH SPRINKLER TYPE. E. PROVIDE METAL STORAGE CABINET FOR EXTRA SPRINKLERS LOCATED ADJACENT TO THE VALVE ASSEMBLY. F. SPRINKLER MANUFACTURERS: AUTOMATIC SPRINKLER OF AMERICA, RELIABLE AUTOMATIC SPRINKLER COMPANY, STAR SPRINKLER COMPANY, VIKING CORPORATION. G. WATER FLOW SWITCH: VANE TYPE SWITCH FOR MOUNTING HORIZONTAL OR VERTICAL, WITH TWO CONTACTS, RATED 10 AMP AT 125 VOLT AC AND 2.5 AMP AT 24 VOLT DC. H. INSTALL SYSTEM IN ACCORDANCE WITH NFPA 13. I. INSPECTOR'S TEST CONNECTION: FOR EACH SPRINKLER SYSTEM AND FOR EACH WATERFLOW ALARM DEVICE, WHERE MULTIPLE DEVICES OCCUR, PROVIDE AN INSPECTOR'S TEST ASSEMBLY. J. PROVIDE A FLOW SWITCH FOR EACH SYSTEM. SET RETARD ON FLOW SWITCHES TO 30 SECONDS OR AS REQUIRE BY LOCAL AUTHORITIES HAVING JURISDICTION. K. WATER CURTAINS AT NON -RATED OPENINGS: a. INSTALL SPRINKLER HEADS ON 6 FOOT CENTERS TO PROVIDE A WATER CURTAIN AT NON -FIRE RATED DOORS AND WINDOWS. LOCATE SPRINKLER HEADS WITHIN 1 FOOT OF THE DOOR OR WINDOW ON BOTH SIDES OF THE DOOR AND WINDOW. b. SPRINKLER HEADS ARE TO BE SUPPLIED FROM THE WET OVERHEAD SPRINKLER SYSTEM. c. WATER CURTAIN SPRINKLER HEADS ARE TO BE HYDRAULICALLY CALCULATED AS A PART OF THE OVERHEAD WET SPRINKLER SYSTEM WITH A MINIMUM DESIGN DISCHARGE OF 3 GPM PER LINEAL FOOT WITH NO SPRINKLER DISCHARGING LESS THAN 15 GPM. MINIMUM PRESSURE ATA SPRINKLER HEAD IS TO BE 7 PSI. L. EXISTING FIRE PROTECTION SYSTEMS: a. IN BUILDINGS WITH EXISTING FIRE PROTECTION SYSTEMS, THE CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THE OWNER TO MINIMIZE DISRUPTION OF THAT SYSTEM. b. NO FIRE PROTECTION SYSTEM IS TO REMAIN DEACTIVATED AT THE END OF THE WORK DAY UNLESS AGREED TO WITH THE PROPERTY OWNER, AND A SUITABLE FIRE PROTECTION SCHEME SUCH AS A MANNED FIRE WATCH, HAS BEEN IMPLEMENTED AND APPROVED BY THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL FIRE PROTECTION SYSTEMS ARE FILLED, AND THE SYSTEM FUNCTIONAL BEFORE COMPLETING HIS WORK DAY. M. CENTER SPRINKLERS IN ONE DIRECTION ONLY IN CEILING TILE WITH LOCATION IN OTHER DIRECTION VARIABLE, DEPENDENT UPON SPACING AND COORDINATION WITH CEILING ELEMENTS. N. ENSURE REQUIRED DEVICES ARE INSTALLED AND CONNECTED AS REQUIRED TO FIRE ALARM SYSTEM. 0. COORDINATE PIPING WITH STRUCTURAL, MECHANICAL PIPING AND DUCTWORK, AND ELECTRICAL WITHIN THE BUILDING. PIPING CONFLICTS BETWEEN SYSTEM SHALL BE REMOVED AND REPLACED AT NO COST TO THE OWNER. P. CONDUCT ALL APPLICABLE TESTS AS REFERENCED IN NFPA STANDARD 13. ALL NECESSARY TESTS SHALL BE CONDUCTED IN CONFORMANCE WITH REQUIREMENTS OF NFPA. Q. WIRING FOR FLOW SWITCHES, VALVE SUPERVISORY SWITCHES, SUPERVISORY PRESSURE SWITCHES, AND POWER TO AIR COMPRESSORS WILL BE PROVIDED UNDER DIVISION 16. COORDINATE LOCATION OF THESE DEVICES WITH THE ELECTRICAL CONTRACTOR. 15410 PLUMBING FIXTURES AND EQUIPMENT A. MANUFACTURERS: a. WATERCLOSETS; AMERICAN STANDARD, CRANE, ELJER, KOHLER b. URINALS; AMERICAN STANDARD, CRANE, ELJER, KOHLER c. LAVATORIES; AMERICAN STANDARD, CRANE, EWER, KOHLER d. ELECTRIC WATER COOLERS; ELKAY, HALSEY TAYLOR, HAWS, OASIS e. MOP SINKS; FIAT, EL MUSTEE, STERN - WILLIAMS, SWAN f. SERVICE SINKS; FIAT, EL MUSTEE, STERN- WILLIAMS, SWAN g. FAUCETS (LAVATORIES): AMERICAN STANDARD, CRANE, ELJER, KOHLER, DELTA, MOEN, CHICAGO FAUCET, ZURN h. SEATS: BEMIS, BENEKE, CHURCH, OLSONITE, SPERZEL i. CARRIERS: JOSAM, JONESPEC, J.R. SMITH, WADE, ZURN j. INSULATION KITS: TRUBRO, BROCAR, PLUMBEREX SPECIALTY PRODUCTS k. RECEPTORS (FLOOR DRAINS, ETC.): JOSAM, J.R. SMITH, WADE, ZURN I. FLOORNVALL CLEANOUTS: JOSAM, J.R. SMITH, WADE, ZURN m. WATERHEATERS (TANK TYPE): A.O. SMITH, RHEEM/RUUD, STATE n. WATERHEATERS (INSTANTANEOUS): CHRONOMITE LABS, HATCO B. PROVIDE BRACKETS, BRACES OR REINFORCING ANGLES AS REQUIRED IN ALL PARTITIONS NOT SUFFICIENT IN THEMSELVES TO SUPPORT PLUMBING FIXTURES OR OTHER WALL -HUNG EQUIPMENT. C. INSTALL EACH FIXTURE WITH CHROME PLATED, 17 GAUGE TUBING TRAP WITH CLEANOUT, EASILY REMOVABLE FOR SERVICING AND CLEANING. D. INSTALL COMPONENTS LEVEL, PLUMB AND SECURE. E. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL CARRIERS AND BOLTS. F. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SEALANT, COLOR TO MATCH FIXTURE. G. MOUNT LEVER CONTROL FOR HANDICAPPED WATER CLOSETS ON WIDE SIDE OF TOILET STALL. H. INSULATE WASTE AND SUPPLIES FOR ALL HANDICAPPED FIXTURES. I. ROUGH -IN FIXTURE PIPING CONNECTIONS IN ACCORDANCE WITH MINIMUM SIZES INDICATED IN PLUMBING FIXTURE SCHEDULE ON DRAWINGS. J. REVIEW MILLWORK SHOP DRAWINGS. CONFIRM LOCATION AND SIZE OF FIXTURES AND OPENINGS BEFORE ROUGH -IN AND INSTALLATION. K. EXPOSED WATER PIPING CHROME PLATED BRASS. L. PROVIDE SHUT OFF VALVE AND SOLENOID VALVE IN GAS PIPING TO EACH PIECE OF GAS EQUIPMENT. 15732 ROOF TOP AIR CONDITIONING UNIT A. EXISTING ROOF TOP UNIT TO REMAIN. REFER TO SHEET M -1 FOR REFURBISHING REQUIREMENTS AND AIR BALANCE. 15810 DUCTWORK A. PERFORM WORK IN ACCORDANCE WITH SMACNA - HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. B. GALVANIZED STEEL DUCTS: ALL NEW DUCTWORK TO BE ASTM A525 AND ASTM A527 GALVANIZED STEEL SHEET, LOCK- FORMING QUALITY, HAVING G60 ZINC COATING OF IN CONFORMANCE WITH ASTM A90. C. INSULATED DUCT BOARD: INSULATED DUCT BOARD MAY ONLY BE RE -USED WITH PRIOR APPROVAL FROM ENGINEER - CONTRACTOR TO CONTACT ENGINEER FOR APPROVAL PRIOR TO REUSE. D. INSULATED FLEXIBLE DUCTS: a. MANUFACTURERS: FLEX -AIRE, FLEXMASTER, NORFLEX, THERMAFLEX, WIREMOLD. b. TWO PLY VINYL FILM SUPPORTED BY HELICALLY WOUND SPRING STEEL WIRE, FIBERGLASS INSULATION; POLYETHYLENE VAPOR BARRIER FILM. PRESSURE RATING: 10 INCHES WG POSITIVE AND 1.0 INCHES WG NEGATIVE. MAXIMUM VELOCITY: 4000 FPM. TEMPERATURE RANGE: -10 DEGREES F TO 160D DEGREES F. D. FABRICATE AND SUPPORT IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. E. INSTALLATION - GENERAL: a. INSTALL AND SEAL DUCTS IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, UNLESS MORE STRINGENT REQUIREMENTS ARE NOTED IN LOCAL CODES. b. SUPPORT DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, CHAPTER 4, HANGERS AND SUPPORTS (MINIMUM OF 12 GAUGE). c. PROVIDE FIRESTOP SYSTEMS FOR PIPE AND DUCT THROUGH - PENETRATIONS OF THE FOLLOWING FIRE - RESISTANCE RATED ASSEMBLIES, INCLUDING BOTH EMPTY OPENINGS AND OPENINGS CONTAINING PENETRATING ITEMS: FLOORS AND CEILINGS, WALLS AND PARTITIONS, SMOKE BARRIERS, AND CONSTRUCTION ENCLOSED COMPARTMENTALIZED AREAS. d. DUCT HANGERS SHALL NOT ATTACH TO BOTTOM CHORD OF STEEL JOIST OR METAL ROOF DECKING. ATTACH TO TOP CHORD OF STEEL JOIST. e. CONNECT DIFFUSERS OR LIGHT TROFFER BOOTS TO LOW PRESSURE DUCTS DIRECTLY OR WITH 3 FEET MAXIMUM LENGTH OF FLEXIBLE DUCT HELD IN PLACE WITH STRAP OR CLAMP. F. PROTECTION: DURING CONSTRUCTION, PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED POLYETHYLENE ON OPEN DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTWORK SYSTEM. G. CLEANING: a. CLEAN DUCT SYSTEM AND FORCE AIR AT HIGH VELOCITY THROUGH DUCT TO REMOVE ACCUMULATED DUST. TO OBTAIN SUFFICIENT AIR, CLEAN HALF THE SYSTEM AT A TIME. PROTECT EQUIPMENT WHICH MAY BE HARMED BY EXCESSIVE DIRT WITH TEMPORARY FILTERS, OR BYPASS DURING CLEANING. b. CLEAN DUCT SYSTEMS WITH HIGH POWER VACUUM MACHINES. PROTECT EQUIPMENT WHICH MAY BE HARMED BY EXCESSIVE DIRT WITH FILTERS, OR BYPASS DURING CLEANING. 15820 DUCTWORK ACCESSORIES A. COMBINATION FIRE AND SMOKE DAMPERS: a. MANUFACTURERS: CESCO, GREENHECK, NAILOR, POTTRFF, PREFCO, RUSKIN, SAFE -AIR. b. FABRICATE IN ACCORDANCE WITH NFPA 90A, UL 555, UL 5555, LEAKAGE CLASS II, AND AS INDICATED. c. ACTUATORS: UL LISTED AND LABELED SPRING RETURN ELECTRIC TYPE SUITABLE FOR 120 VOLTS, SINGLE PHASE, 60 HZ. [ELECTRIC TYPE SUITABLE FOR 24 VOLTS, DC.] LOCATE DAMPER OPERATOR ON EXTERIOR OF DUCT AND LINK TO DAMPER OPERATING SHAFT. PROVIDE FOR TESTING OR RESETTING AT DAMPER. B. FIRE DAMPERS: a. MANUFACTURERS: AIR BALANCE, CESCO, GREENHECK, NAILOR, POTT RFF, PREFCO, RUSKIN, SAFE -AIR. b. FABRICATE IN ACCORDANCE WITH NFPA 90A AND UL555, AND AS INDICATED. C. SMOKE DAMPERS: a. MANUFACTURES: AIR BALANCE, CESCO, GREENHECK, NAILOR, POTTO RFF, PREFCO, RUSKIN, SAFE -AIR. b. FABRICATE IN ACCORDANCE WITH NFPA 90A, UL 555, UL 555S, [LEAKAGE CLASS I] [LEAKAGE CLASS II], AND AS INDICATED. c. ACTUATORS: UL LISTED AND LABELED SPRING RETURN ELECTRIC TYPE SUITABLE FOR 120 VOLTS, SINGLE PHASE 60 HZ. [ELECTRIC TYPE SUITABLE FOR 24 VOLTS, DC]. LOCATE DAMPER OPERATOR ON EXTERIOR OF DUCT AND LINK TO DAMPER OPERATING SHAFT. PROVIDE FOR TESTING OR RESETTING AT DAMPER. D. INSTALL ACCESSORIES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, NFPA 90A, AND FOLLOW SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE. E. INSTALL CONTROL DAMPERS FURNISHED IN SECTION 16906. F. PROVIDE BACKDRAFT DAMPERS ON EXHAUST FANS OR EXHAUST DUCTS NEAREST TO OUTSIDE AND WHERE INDICATED. 15830 FANS A. MANUFACTURERS: GREENHECK, COOK, JENN -AIR, TWIN CITY FAN. B. INSTALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 15850 AIR OUTLETS AND INLETS A. GRILLES, REGISTERS AND DIFFUSERS: a. MANUFACTURERS: TITUS, ANEMO STAT, KRUEGER, METALAIRE, NAILOR, PRICE, TUTTLE & BAILEY. B. LOUVERS: a. LOUVER BY OTHERS AMERICAN WARMING AND VENTILATING. b. MANUFACTURERS: AMERICAN WARMING AND VENTILATING, ARROW UNITED, CESCO, GREENHECK, LOUVERS AND DAMPERS, RUSK IN. C. GRAVITY ROOF VENTILATORS: a. MANUFACTURERS: COOK, GREENHECK, PENN. D. GOOSENECKS: a. FABRICATE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, OF MINIMUM 18 GAGE GALVANIZED STEEL. b. MOUNT ON MINIMUM 12 INCH HIGH CURB BAS WHERE SIZE EXCEEDS 9 X 9 INCH. 15895 HVAC CLEANING SYSTEM A. SECTION INCLUDES: a. MECHANICAL CLEANING OF HVAC SYSTEMS TO INCLUDE THE REMOVAL OF DIRT, BACTERIA, FUNGI, DUST AND DEBRIS THAT HAS ACCUMULATED INSIDE THE DUCTS AND HVAC EQUIPMENT. b. CLEANING OF ALL SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK, DIFFUSERS, GRILLES AND REGISTERS. c. CHEMICAL PRESSURE WASHING AND DECONTAMINATION OF ALL HEATING AND COOLING COILS. d. DECONTAMINATION OF DAMPERS, SUPPLY AIR FANS, RETURN AIR FANS AND OTHER COMPONENTS. B. QUALITY ASSURANCE: a. SERVICES PROVIDED BY VENTILATION CLEANING CONTRACTOR CERTIFIED BY NATIONAL AIR DUCT CLEANERS ASSOCIATION (NADCA). b. PERFORM HVAC SYSTEM CLEANING IN ACCORDANCE WITH NADCA STANDARD 1992 -01. C. CLEANING CHEMICALS: a. DEGREASER AS MANUFACTURED BY; ZEP OR APPROVED SUBSTITUTION. b. COIL CLEANER AS MANUFACTURED BY: RENEUZ OR APPROVED SUBSTITUTION. D. VACUUM COLLECTION SYSTEM: a. HEPA FILTERED VACUUM RATED AT 4000 CFM AND ABLE TO MAINTAIN 1.5 INCHES OF STATIC PRESSURE INSIDE THE ISOLATED AREA OF DUCTWORK. b. AIR COMPRESSOR CAPABLE OF PROVIDING A MINIMUM OF 160 PSI AT 26 CFM. c. RBS -1500 ROTARY BRUSH SYSTEM FOR MECHANICALLY CLEANING ALL TYPES OF DUCTWORK AND VENTILATION SHAFTS. E. EXAMINATION: a. VERIFY CONDITIONS AT SITE BEFORE COMMENCING WORK F. PREPARATION: a. PROTECT ALL FURNISHINGS, EQUIPMENT, ETC. IN WORK AREA WITH POLYETHYLENE OR EQUIVALENT. b. SEAL OFF ENDS AND OPENINGS OF ANY DUCTWORK, NOT BEING IMMEDIATELY WORKED ON. c. PROTECT ALL INTERNAL DUCT DEVICES SUCH AS TURNING VANES, COILS, FIRE DAMPERS, SENSORS, ETC., FROM COATING OVERSPRAY. d. SUPPORT AND BRACE DUCTWORK WHICH WILL BE ENTERED BY PERSONNEL FOR DECONTAMINATION. e. ISOLATE EQUIPMENT WHICH GENERATES NOISE FROM OCCUPIED AREAS. f. MARK ALL AIR VOLUME CONTROL DAMPER POSITIONS PRIOR TO CLEANING AND RESTORE TO MARKED POSITION AT COMPLETION OF WORK G. ACCESS DOORS: a. PROVIDE DUCT ACCESS DOORS FOR INSPECTION AND CLEANING BEFORE AND AFTER FILTERS, COILS, FANS, HUMIDIFIERS, DUCT MOUNTED SMOKE DETECTORS, AUTOMATIC DAMPERS, AT FIRE DAMPERS, COMBINATION FIRE AND SMOKE DAMPERS, AND ELSEWHERE AS INDICATED. PROVIDE MINIMUM 8 X 8 INCH SIZE FOR HAND ACCESS. 18 X 18 INCH SIZE FOR SHOULDER ACCESS, AND AS INDICATED. REVIEW LOCATIONS PRIOR TO FABRICATION. H. DUCTWORK a. DETERMINE ACCESS POINTS TO FACILITATE CLEANING SECTION BY SECTION. b. PROVIDE WITHIN THE DUCTWORK DISTRIBUTION SYSTEM, PROTECTIVE SEALS OF ANY AREAS DOWNSTREAM FROM RECEIVING PARTICULATES DURING THE INSTALLATION OF ACCESS POINTS. c. CUT EXISTING EXTERIOR DUCT INSULATION AND DUCT TO PROVIDE AN ACCESS DOOR TO FACILITATE CLEANING. MAXIMUM SIZE OF ACCESS TO BE 22" X 22 ". 15906 AUTOMATIC CONTROLS (RTU) A. SEQUENCE OF OPERATION: ROOFTOP UNIT, DX COOLING WITH GAS HEAT a. EXISTING CONTROL SEQUENCE TO REMAIN UNCHANGED. RECLivttj (1T ' OF TUKWILA MaY 302012 DERMIT CENTER S PERMIT AN PARATE � OVAL REQUIRED 0412755 -139 DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 Fax 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: MJI CHECKED BY: GMS SQ. FT. CALCS RETAIL- 1,170 SF TOTAL: 1,682 SF wnc�r: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE HUM # ## 0 W fx <C w 000 I—_ (n W 00 minx U O WmI—Q z 0 =L><JOJ I-OLn: Q N Y CI- V) U)— PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE A n n n A SCALE: AS NOTED MECHANICAL SPECIFICATIONS M - ELECTRICAL SYMBOLS SYMBOL DESCRIPTION MOUNTING MI x DUPLEX RECEPTACLE, NORMAL POWER 18" RECEPTACLE OPTIONS DENOTED BY "X" WHERE "X" CAN BE ONE OF THE FOLLOWING: IG = ISOLATED GROUND GFI = GROUND FAULT INTERRUPTER TR = TAMPER RESISTANT SS = SURGE SUPRESSOR WP = WEATHERPROOF (blank)= STANDARD RECEPTACLE 4 FOURPLEX RECEPTACLE 18" MULTIOUTLET ASSEMBLY, REFER TO SPEC FOR TYPE O I AND RECEPTALE SPACING .. FIXTURE EXTENSION []J DISCONNECT SWITCH, NON -FUSED {J DISCONNECT SWITCH, FUSED Ms MOTOR STARTER SWITCH WITHOUT OVERLOAD 54" 1/) PROTECTION Mss MOTOR STARTER SWITCH WITH OVERLOAD 54" I (I) PROTECTION EF -1 MOTOR STARTER WITH EQUIPMENT NUMBER MAGNETIC I INDICATED EF -1 COMBINATION MOTOR STARTER AND FUSED DISCONNECT WITH EQUIPMENT NUMBER INDICATED x SWITCH, WHERE "X" CAN BE ON OF THE FOLLOWING: 46" I Cl) 2 = DOUBLE POLE 3 = THREE WAY 4 = FOUR WAY MC = MOMENTARY WITH RTC OS = OCCUPANCY SENSOR -DUAL TECHNOLOGY WATT STOPPER DW -100 OS3= OCCUPANCY SENSOR -DUAL TECHNOLOGY MULTI WAY WATT STOPPER DW -103 OS = OCCUPANCY SENSOR -DUAL TECHNOLOGY a/b DUAL RELAY WATT STOPPER DW -200 OS3= OCCUPANCY SENSOR -DUAL TECHNOLOGY a/b DUAL RELAY MULTI WAY WATT STOPPER DW -203 (blank or letter (a, b, c, d, etc...)) = SINGLE POLE KPl -I KEY PAD 60" Fill DIMMER SWITCH 46" HO JUNCTION BOX, RECESSED WALL 18" 0 JUNCTION BOX, RECESSED CEIUNG • FEI PUSHBUTTON (EDWARDS 852) 46" CI TIME CLOCK kill CONTACTOR TELEPHONE - DESK 18" VOICE /DATA OUTLET 18" x FIRE ALARM DEVICE, WHERE "X" CAN BE ONE OF F THE FOLLOWING: (blank)FIRE ALARM MANUAL PULL STATION 46" P PHOTOELECTRIC SMOKE DETECTOR DS DUCT SMOKE DETECTOR FS FLOW SWITCH TS TAMPER SWITCH F • FIRE ALARM STROBE 90" OR 6" BELOW FINISHED CEILING WHICH • EVER IS LOWER FIRE ALARM HORN WITH 90" OR 6" BELOW F STROBE FINISHED CEILING WHICH EVER IS LOWER LOW VOLTAGE CONTROL 90" OR 6" BELOW T TRANSFORMER FINISHED CEILING WHICH DORMEYER DCT -10 -120 EVER IS LOWER BZ BUZZER 90" OR 6" BELOW TRIDENT 1 FD14 FINISHED CEILING WHICH EVER IS LOWER NOTE: SYMBOL LEGEND IS FOR REFERENCE ONLY. ALL SYMBOLS MAY NOT BE UTILIZED ON PLANS. DESIGN PRESENTATION DESCRIPTION 0. KEY NOTE, REFER TO LIST OF KEY NOTES ON THE SAME PLAN ADRAWING REVISION NOTE ELECTRICAL SHEET I DEX E -1 POWER PLAN, SCHEDULES, SERVICE RISER AND CALCULATIONS E -2 LIGHTING PLAN AND SCHEDULES E-3 ELECTRICAL SPECIFICATIONS AND DETAILS E-4 ELECTRICAL TITLE 24 DEMOLITION NOTE: PROVIDE ALL ELECTRICAL DEMOLITION WORK IN EXISTING SPACE AND REWORK AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. SEE ARCHITECTURAL PLANS, FIXTURE PLANS AND MECHANICAL DEMOLITION PLANS FOR SCOPE OF DEMOLITION. WHERE EXISTING WALLS, CEILINGS, FLOORS OR LIGHT FIXTURES ARE BEING REMOVED, REMOVE ALL ELECTRICAL EQUIPMENT, DEVICES, BOXES, CONDUITS, WIRES, ETC. IN OR ON THE WALLS, FLOORS, OR CEILING. EXTEND ALL WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE TO ELECTRICAL EQUIPMENT THAT REMAINS IN SERVICE. PROVIDE TEMPORARY WIRING AS REQUIRED. NOTE: ELECTRICAL CONTRACTOR TO PROVIDE CIRCUIT BREAKERS IN EXISTING PANELS AS REQUIRED. MATCH MANUFACTURER AND RATINGS. EACH SINGLE POLE BRANCH CIRCUIT SHALL BE PROVIDED WITH SEPARATE NEUTRAL CONDUCTOR. IF EC INSTALLS MULTIWIRE BRANCH CIRCUIT A MULTIPOLE BREAKER SHALL BE INSTALLED PER THE SPECIFICATION AS MEANS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES PER NEC 210.4B. 5 A B D E F G 2 3 4 5 6 7 8 9 10 11 12 13 14 RETAIL SERVICE CALCULATION FORM (3 -PHASE SERVICE) ENTER STORE SQUARE FOOTAGE ENTER TOTAL LENGTH OF TRACK LTG ENTER TOTAL LENGTH OF SHOW WINDOW ENTER LARGEST MOTOR LOAD ENTER NUMBER OF KITCHEN ITEMS OR 6 FOR 6 OR > ENTER LARGEST TWO KITCHEN EQUIPMENT LOADS ENTER NUMBER OF SIGN CIRCUITS LIGHTING (MINUS TRACK/SIGN LTG) SIGN CIRCUIT TRACK LIGHTING 75W /FT TRACK LIGHTING CONNECTED SHOW WINDOW 200W /FT CONVENIENCE RECEPTACLES UP TO 10 KVA CONVENIENCE RECEPTACLES ABOVE 10 KVA EQUIPMENT (R category) HVAC COOLING ONLY MOTORS (DEMAND INCLUDES +25% OF LARGEST MOTOR) ELECTRIC HEAT WATER HEATER KITCHEN EQUIPMENT MINIMUM LIGHTING LOADS PER NEC 220.12 3VA /SQFT TOTALS ENTER VOLTAGE LINE TO LINE MINIMUM AMP SERVICE REQUIRED 16132 90 8 6408 1 CONNECTED VA SQ. FT. FEET FEET VA ITEMS VA NEC FACTOR CALCULATED LOAD (VA) 2500 1200 6750 494 1600 10000 4800 1200 0 10141 0 3000 5046 46731 208 120 1.25 1.25 1.25 1.25 1.25 1.00 0.50 1.00 1.00 1.00 1.00 1.00 1.00 1.25 3 -PHASE 3125 1500 8438 618 2000 10000 2400 1200 0 10141 0 3000 0 6308 3125 1500 8438 0 2000 10000 2400 1200 0 11743 0 3000 0 43406 Note: Calculated loads include larger of the following lines: ((1 +(Largest of 3or4)) or 14), largest of 3 or 4, largest of 13 or F, Largest of 11 or 9 Panel: LA Voltage: 120/208v, 3Ph, 4w No. Amp /p Note Description Ph Code L VA Code C VA R VA Code M VA Code E VA Code K VA Code D VA 1 20/1 2 LED SIGN - A - 1200 DISC. 60 NF UNIT LA 40/3 3 20/1 2 STOREFRONT LIGHTING - B - 19 360 5 20/1 TRACK & PENDANT LIGHTING - C - 571 7 20/1 STOCK /OFFICE LIGHTING - A - 255 9 20/1 SALES LIGHTING - B - 1556 11 20/1 SPARE - C - 13 20/1 RCPTS.- MANAGERS DESK -A - 720 15 20/1 RCPTS. -MUSIC SYSTEM / PRINTERS - B - 720 17 20/1 1 SECURITY SYSTEM RECEPTS -c- 360 19 20/1. RCPT SHOPPERTRAK /DOOR XFORMER - A - 190 21 20/1 1 TOILET LTG /FAN - B - 61 192 23 20/1 KIOSK -c- 360 25 20/1 1 RCPT PHONEBOARD/T1ME CLOCK - A - 920 27 20/1 DRINKING FOUNTAIN - B - 360 29 20/1 SPARE -c - 31 20/1 SPARE -A - 33 20/1 SPARE - B - 35 20/1 SPARE - C - 37 40 EXISTING RTU -1 - A - 3380 39 / - B - 3380 41 3 - C - 3380 2 20/1 RCPTS. -CASH REGISTER - A - 720 4 20/1 RCPTS. -CASH REGISTER - B - 720 6 20/1 RCPTS. - DEACTIVATOR PADS -c- 720 8 20/1 RCPTS.- TABLES - A - 720 10 20/1 RCPTS. - TABLES - B - 720 12 20/1 RCPTS.- SLATWALL -c- 900 14 20/1 RCPTS.- SLATWALL - A - 900 16 20/1 RCPTS.- SLATWALL - B - 900 18 20/1 RCPTS.- SLATWALL -c- 900 20 20/1 RCPTS.- SLATWALL - A - 540 22 20/1 SPARE - B - 24 20/1 1 DUCT SMOKE DETECTOR -c- 100 26 20/1 SERVICE RCPT. / TOILET - A - 360 28 20/1 RCPTS. -SALES FLOOR - B - 1080 30 25/1 1 EXISTING WATER HEATER - C - 3000 32 20/1 SPARE - A - 34 20/1 RCPTS. - SLATWALL - B - 900 36 20/1 RCPTS.- SLATWALL - C - 900 _ 38 20/1 RCPTS.- SLATWALL -A - 900 40 20/1 SPARE - B - 42 20/1 SPARE -c- Through Feed Connection NONE - A - Lug ' - - B - - -c - Main Breaker 200 - A - 1455 4860 1110 3380 0 0 0 / - B - 1636 5760 0 3572 0 0 0 3 -C- 571 4140 3100 3380 0 0 0 Overcurrent Device Notes: Conn KVA phase loads Total - A - - B - - C - 1 - PROVIDE LOCK -ON DEVICE 33.0 10.8 11.0 11.2 2 - CIRCUIT VIA TIME CLOCK Dmd Conn Bus KVA loads 3 _ 4.6 3.7 Code L - Lighting 4 - 12.4 14.8 Code C 'Convenience Receptacles (180 W) 5 - 4.2 4.2 Code R - 'Receptacles (Non Convenience) Panelboard Notes: 11.9 10.3 Code M -'Motors Largest Mtr VA = 6408 1 1 - 0.0 0.0 Code E - 'Electric Heat 2 - 0.0 0.0 Code K - 'Kitchen Equip Dmd _ 100% 1 3 - 0.0 0.0 Code D - Dwelling Units (Hotel /Motel Rooms) 4 - 33 33 Total KVA 5 - 0 Spare KVA Spare = 0% RECESSED : Mounting 33 Adjusted KVA (Demand + Spare KVA) EXISTING : Amps AIC Rating 92 Adjusted Amps (Demand + Spare. KVA) 200 : Amp Rating of Bus 99 High Phase Amps (Demand + Spare KVA) I 200 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 208 : Phase to Phase Voltage I PANEL LA 412755 -139 BEST BUY MOBILE GENERAL NOTES A. OUTLETS, SWITCHES AND COVERPLATES ARE TO BE LEVITON "DECORA ", WHITE IN COLOR, UNLESS NOTED OTHERWISE. COORDINATE MOUNTING HEIGHTS IN FIELD. B. PROVIDE MULTIPLE GANG COVER PLATES FOR ADJACENT OUTLETS AND SWITCHES. C. PROVIDE ACOUSTICAL SEALANT AT BACKBOXES IN INSULATED WALLS. D. 120 VOLT BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. E. SEPARATE ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS A MINIMUM OF 24" HORIZONTAL. F. HOME RUNS SHALL BE 3/4" CONDUIT UNLESS NOTED OTHERWISE. G. UNLESS NOTED OTHERWISE ON THE PLANS, USE DEVICE MOUNTING HEIGHTS NOTED ON THE ELECTRICAL SYMBOL LEGEND. H. LINEAR FLUORESCENT LUMINAIRES SHALL BE INSTALLED TO MEET THE REQUIREMENTS OF NEC REGARDING LOCAL DISCONNECTING MEANS. POWER PLAN KEY NOTES O THE CASH WRAP CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CONDUIT FOR GROUNDING. <> PROVIDE DOUBLE DUPLEX RECEPTACLE AT P.O.S. TILL. ON DEDICATED 20 AMP CIRCUIT. MOUNT INSIDE CABINET AS DIRECTED BY FIXTURE SUPPLIER. % ELECTRICAL CONTRACTOR TO VERIFY WITH FIXTURE SHOP DRAWINGS FOR THE LOCATION OF BBM FURNISHED FIXTURE EXTENSION DROP FOR THE DISPLAY FIXTURE PRIOR TO ROUGH -IN. PROVIDE 2 DOUBLE DUPLEX RECEPTACLES WITHIN FIXTURE CABINET. COORDINATE WITH FIXTURE INSTALLER. O4 PROVIDE CONDUIT CONCEALED IN WALL TO CONNECT MULTI OUTLET ASSEMBLY, FURNISHED BY SLAT WALL MANUFACTURER (ASSEMBLY COMES IN FIVE FOOT LENGTHS WITH SINGLE RECEPTACLES 12" O.C.). EC SHALL MOUNT ASSEMBLY AT 37.5" FROM BOTTOM OF FIXTURE WITH A MAXIMUM OF 10' OF ASSEMBLY PER CIRCUIT. SEE DETAIL FOR ADDITIONAL INFORMATION. EC SHALL FIELD MODIFY ASSEMBLY TO PROPER LENGTH AS FIELD CONDITIONS REQUIRE. <> PROVIDE CEILING MOUNT DUPLEX RECEPTACLE FOR SECURITY DEVICE. MOUNT 30" OUT FROM DOOR AND 1' -0" TO THE RIGHT OF THE CENTERLINE OF DOOR. 6O PROVIDE POWER AND DATA FOR CONNECTION OF PRINTER /DATA TRANSFER DEVICE. <> PROVIDE 1 1/4" EMPTY CONDUIT WITH PULL LINE FROM SERVER RACK TO FLUSH MOUNTED JUNCTION BOX AT 12" A.F.F. AT P.O.S. STATION FOR VOICE /DATA OUTLETS. PROVIDE NYLON BUSHINGS AT EACH END. ': FLUSH CEILING MOUNTED DISPLAY WINDOW RECEPTACLE. 9O E.C. TO PROVIDE AND INSTALL NEW PARAGON MODEL 7000 - SERIES OR EQUAL, WITH 7 DAY, 24 HOUR SCHEDULING FORMAT. MIN (4) N.O. 20 AMP, 120/277 VOLT CONTACTS, 120 VOLT COIL AND SPRING WOUND RIDE THROUGH. SWITCH SHALL CONTROL STORE FRONT LIGHTING AND SIGN LIGHTING. PROGRAM SO LIGHTS TURN ON 1 HOUR BEFORE STORE OPENING AND TURN OFF 1 HOUR AFTER CLOSE. POWER PLAN KEY NOTES cont. • PROVIDE 24" X 24" X 1/2" PLYWOOD FOR TELECOM EQUIPMENT MOUNTING ABOVE SERVER CABINET. PROVIDE #6 AWG CONTINUOUS COPPER GROUND WIRE AND CONDUIT FROM THE BUILDING SERVICE GROUND BUS TO THE COMMUNICATION AREA. BUS BAR IS PROVIDED BY BBM I.S. VERIFY REQUIREMENTS WITH THE AUTHORITY HAVING JURISDICTION BEFORE INSTALLING EQUIPMENT GROUND. SEE DETAIL 8/E -3. 11 PROVIDE 2" CONDUIT FROM 7' -2" A.F.F. TO DECK WITH 90 DEG. SWEEP AT DECK FOR COMMUNICATIONS ENTRANCE CABLING. PROVIDE NYLON BUSHING AT BOTH ENDS. 12 POWER CABLING AT P.O.S. TILLS IS TO BE ROUTED DOWN THE WALL TO FLUSH MOUNTED JUNCTION BOX AT 12" AF.F. AND INTO THE P.O.S. STAND TO DOUBLE DUPLEX RECEPTACLES. 13 PROVIDE 2" SLEEVE THROUGH WALL (ABOVE DOORWAY IF POSSIBLE) TO ALLOW LOW VOLTAGE CABLE TO TRANSFER FROM REAR OF HOUSE TO FRONT OF HOUSE. PENETRATE WALL AT JOIST HEIGHT. FIRE SEAL AS REQUIRED. 14 ELECTRIC WATER HEATER 'WH -1' IS EXISTING TO REMAIN. FIELD VERIFY THAT EXISTING ELECTRICAL DEVICES ARE IN GOOD CONDITION. REPLACE OR REPAIR AS REQUIRED. 15 SECURITY SYSTEM AND ASSOCIATED EQUIPMENT IS TO BE FURNISHED AND INSTALLED BY BBM. TENANT'S E.C. IS TO FURNISH AND INSTALL J- BOXES, CONDUITS AND PULL STRINGS WHERE APPLICABLE. REFER TO DETAILS 2 THROUGH 6 SHEET E -3 FOR SPECIFIC REQUIREMENTS. 16 PROVIDE VOICE /DATA OUTLET RECESSED IN CEILING FOR TRAFFIC COUNTER. PLACE 30" OUT FROM DOORS AND 1' -0" TO THE LEFT OF THE CENTERLINE OF DOORS. 17 PROVIDE CONNECTION FROM DOORBELL /PUSHBUTTON TO BUZZER /TRANSFORMER. 18 VERIFY DUCT SMOKE DETECTOR EXISTS. PROVIDE AND INSTALL NEW SMOKE DETECTOR AS REQUIRED. SMOKE DETECTOR TO SHUT DOWN HVAC UNIT UPON DETECTION OF SMOKE. E.C. TO VERIFY WITH MALL REPRESENTATIVE IF DETECTOR IS REQUIRED TO BE TIED INTO MALL FIRE ALARM SYSTEM. PROVIDE CONNECTIONS AS REQUIRED. 19 PROVIDE GFI RECEPTACLE FOR DRINKING FOUNTAIN. VERIFY EXACT LOCATION WITH MECHANICAL. 20 PROVIDE DOUBLE DUPLEX RECEPTACLE MOUNTED INSIDE OF P.O.S. TABLE FOR SENSORMATIC DEACTIVATOR PADS. VERIFY BEST MOUNTING LOCATION WITH FIXTURE SUPPLIER. 21 • PROVIDE DUPLEX RECEPTACLE MOUNTED AT 18" A.F.F. FOR GENERAL POWER. 22 APPROXIMATE LOCATION OF EXISTING DUPLEX RECEPTACLE. CLEAN AND CHECK FOR PROPER OPERATIONS, REPLACE AS REQUIRED. 23 PROVIDE 2" X 4" JUNCTION BOX AND 1/2" CONDUIT WITH PULL LINE TO HVAC UNIT FOR CONTROL OF T -STAT. COORDINATE WITH MECHANICAL PLANS. NOTE: 1. E.C. TO SURVEY EXISTING C❑NDITI ❑NS. VERIFY EXISTING CONDUIT /CONDUCT ❑RS /METERING AND ROUTING OF CONDUIT TO LANDLORD'S SPACE, REPORT ANY DISCREPANCIES TO ELECTRICAL DESIGNER. EXISTING LANDLORD 120/208V, 3PH, 4W 1200A ELECTRICAL DISTRIBUTION. LEASE LINE MEASURE STEADY STATE LOAD CURRENTS AT PANELBOARD FEEDER. SHOULD THE DIFFERENCE BETWEEN PHASES EXCEED 10 %, REARRANGE CIRCUITS TO BALANCE THE PHASE LOADS TO WITHIN 10 %. PROVIDE TYPEWRITTEN DIRECTORY REVISED TO REFLECT CIRCUITING CHANGES REQUIRED TO BALANCE PHASE LOADS. PROVIDE A COPY OF THE LOAD BALANCE DATA TO THE MALL'S CENTER OF OPERATIONS DIRECTOR. EXISTING 2 "C -4 #3/0 & 1 #6 GROUND. O\ EXISTING /) 200A /3P O BREAKER LANDLORD'S SPACE P EXISTING PANEL 'LA' 200A MCB 120 /208V E.0 TO PR ❑VIDE AND INSTALL NEW TIME CLOCK 'TC -l. SEE POWER KEYED NOTE 9. CIRCUIT BREAKERS SHALL BE BOLT ON MOLDED CASE. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE 'SWD' RATED. TENANT'S SPACE 2 \ ELECTRICAL RISER DIAGRAM El NOT TO SCALE SLAT WALL ABOVE AND BELOW ASSEMBLY MULTI OUTLET ASSEMBLY MOUNTED 37.5" FROM B.O. OF THE FIXTURE BASE TO B.O. PLUG MOLD VERIFY WITH FIXTURE LOCK NUT \\ / N CONDUIT BACK TO ELEC. PANEL WALL CAVITY 1 LA-2,4,6 GF ROOM A-26 42" 103 TOILET SHOPPER TRAK WALL MTD. MODEM ENCL. BOTTOM AT 5' -0" AF PANEL LA LA -2,4,6 ©64" /LA -1-9- �.� LA-19 .64 A�2�5 18 " /LA -25 ELECTRICAL EQUIPMENT SCHEDULE EQUIPMENT TAG EQUIPMENT DESCRIPTION HP /LOAD VOLT/ DISCONNECT POWER SOURCE FEEDER SIZE ELEC NOTES TYPE SIZE FUSE LOC. PANEL CB CKT# EXISTING ROOF TOP UNIT 31.3 MCA 208/3 DISC. 60 NF UNIT LA 40/3 37,39,41 EXISTING 1,2 R 0 NOTES: 1. MAINTAIN CONNECTION TO DUCT SMOKE DETECTOR (CKT# LA -24). ROOF TOP UNIT IS EXISTING TO REMAIN. RECONNECT TO NEW ELECTRICAL PANEL AS SHOWN. MAINTAIN CONNECTION TO EXISTING WP GFI SERVICE RECEPTACLE CCKT LA-26). 2. MECHANICAL EQUIPMENT CIRCUITRY AND CONTROL: VERIFY CIRCUIT BREAKER AND BRANCH CIRCUITRY TO BE TN ACCORDANCE WITH MANUFACTURER'S NAME -PLATE DATA REQUIREMENTS. LA -3 SALES LA -26 WP /GFI SECURITY LA -17 PANEL ELECTRICAL POWER PLAN El \I SCALE: 1 /4" = 1 ' -0" LA -3 LOW VOLTAGE NOTE: ALL LOW VOLTAGE IS REQUIRED TO BE INSTALLED IN CONDUIT. PROVIDE CONDUIT WITH PULL STRING AS REQUIRED. VERIFY ALL LOCATIONS WITH BBYM. VERIFY ALL REQUIREMENTS WITH LOCAL AHJ, LANDLORD, AND BBYM. FIRE ALARM NOTE: FIRE ALARM WORK TO BE COMPLETED BY LANDLORD APPROVED FIRE ALARM CONTRACTOR. EC TO INCLUDE COSTS FOR FIRE ALARM WORK IN THEIR BID. FIRE ALARM SYSTEM MUST TIE INTO MALL SYSTEM. QARATE � APR MrTgND RED REGLIvt_LI. CITY OF TUKWIL A MAY 3 0 2012 PERMIT CENTER 0412755 -139 MI DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: T1_ CHECKED BY: RM SQ. FT. CALCS RETAIL: 1,170 SF TOTAL 1,682 SF car: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE # ## Q 0 W Q W oo Uo W m N Q w lko 0 =wo- DQNY OCI-ND V) V) D- PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE A 0 n A A POWER PLAN, SCHEDULES, SERVICE RISER AND CALCULATIONS F TOILET ROOM 103 REFER TO ARCHITECTURAL ELEVATION FOR TABLE TRACK & PENDANT LUMINAIRE MOUNTING HEIGHTS. ELECTRICAL LIGHTING PLAN E2y SCALE: 1 /4" = 1 ' —O" HALO CURRENT LIMITERS AMPS MODEL # 1A CB120 2.5A CB300 5A CB600 8A CB960 10A CB1200 LC901 = END FEED LC903 = CENTER FEED NOTE: ELECTRICAL CONTRACTOR TO RELAMP EXISTING LIGHT FIXTURES. CLEAN /REPAIR TO LIKE NEW CONDITION. PROVIDE NEW AS REQUIRED. GENERAL NOTES A. OUTLETS, SWITCHES AND COVERPLATES ARE TO BE LEVITON "DECORA ", WHITE IN COLOR, UNLESS NOTED OTHERWISE. COORDINATE MOUNTING HEIGHTS IN FIELD. B. PROVIDE MULTIPLE GANG COVER PLATES FOR ADJACENT OUTLETS AND SWITCHES. C. PROVIDE ACOUSTICAL SEALANT AT BACKBOXES IN INSULATED WALLS. D. 120 VOLT BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. E. SEPARATE ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS A MINIMUM OF 24" HORIZONTAL. F. HOME RUNS SHALL BE 3/4" CONDUIT UNLESS NOTED OTHERWISE. G. UNLESS NOTED OTHERWISE ON THE PLANS. USE DEVICE MOUNTING HEIGHTS NOTED ON THE ELECTRICAL SYMBOL LEGEND. H. LINEAR FLUORESCENT LUMINAIRES SHALL BE INSTALLED TO MEET THE REQUIREMENTS OF NEC REGARDING LOCAL DISCONNECTING MEANS. LIGHTING PLAN KEY NOTES O SWITCH 'a' AND 'b' SHALL CONTROL LIGHTING CIRCUIT LA -9. SWITCH 'c' SHALL CONTROL PENDANT AND TRACK LIGHTING CIRCUIT LA -5. • PROVIDE J -BOX AND DISCONNECTING MEANS IN ACCESSIBLE CEILING SPACE FOR CONNECTION OF LED SIGN POWER. COORDINATE REQUIREMENTS PRIOR TO ROUGH -IN. ROUTE SIGN CIRCUIT VIA TIME CLOCK. REFER TO KEY NOTE #9 ON POWER PLAN FOR SOURCE. FINAL CONNECTION OF SIGN BY SIGN VENDOR. • ROUTE STORE FRONT LIGHTING CIRCUIT VIA TIME CLOCK. REFER TO KEY NOTE #9 ON POWER PLAN. O NEW FAN /LIGHT COMBO IN EXISTING TOILET ROOM. FIELD VERIFY THAT SWITCH /ES ARE IN PROPER WORKING CONDITION. REPAIR OR REPLACE AS REQUIRED. OPROVIDE UNSWITCHED CIRCUITS TO EMERGENCY BATTERY TYPE 'X2' AND EXIT SIGNS 'X1' AND NIGHT LIGHTS. OPROVIDE INTEGRAL TRACK CURRENT LIMITER AS SHOWN. SEE TABLE FOR MODEL NUMBERS. EXISTING FIXTURE TO BE RELOCATED. CLEAN AND RELAMP EXISTING LIGHT FIXTURE. REBALLAST AS REQUIRED. RECONNECT TO ELECTRICAL PANEL AS SHOWN. OTRACK AND PENDANT LIGHTING AT CENTER TABLES TO BE MOUNTED TO TABLE CANOPY. SEE FIXTURE SHOP DRAWINGS FOR MORE INFORMATION. ROUTE POWER FROM CEILING DOWN FIXTURE EXTENSION. FIXTURE EXTENSION SUPPLIED BY FIXTURE SUPPLIER. .q> EXISTING FIXTURE TO REMAIN. CLEAN AND RELAMP EXISTING LIGHT FIXTURE. REBALLAST AS REQUIRED. RECONNECT TO ELECTRICAL PANEL AS SHOWN. 10 VERIFY ADEQUATE GENERAL AND EMERGENCY LIGHTING EXISTS. PROVIDE NEW MATCHING AS REQUIRED. REPAIR OR REPLACE EXISTING FIXTURES AS REQUIRED. VERIFY ALL REQUIREMENTS WITH LANDLORD AND LOCAL AHJ. r r. LUMINAIRE SCHEDULE L.) ,..' TOTAL VA PER FIXTURE SYMBOL LTR TYPE LUMINAIRE TYPE MOUNTING LAMP TYPE VOLTAGE/ BALLAST LUMINAIRE DESCRIPTION MANUFACTURER/ CATALOG SERIES 61 B 2X2 FLUORESCENT RECESSED LAY -IN GRID CEILING (2)F31 T8 SPX35 U 120/277V 2X2 RECESSED, GRID LAY -IN FLUORESCENT PARABOLIC TROFFER COOPER LIGHTING - METALUX #2EP3GX- 2U1 -5/8 S331- UNV -EB81 -2BC -U ••• ••• 61 BE 2X2 FLUORESCENT WITH BATTERY BACKUP RECESSED LAY -IN GRID CEILING (2)F31 T8 SPX35 U 120/277V 2X2 RECESSED, GRID LAY -IN FLUORESCENT PARABOLIC TROFFER WITH EMERGENCY BATTERY BALLAST COOPER LIGHTING - METALUX #2EP3GX- 2U1 -5/8 S331 -(120 OR 277 VERIFY)- EL- FBP240H -EB81 -2BC -U ••• 1■ • 75 /FT 19 19 .. D D1 DM TRACK TRACK LIGHT FIXTURE MONO POINT SURFACE /PENDANT TRACK SURFACE - -- 19W LED 19W LED 120V TRACK LED WIDE FLOOD MONO POINT CONNECTION HALO #L650, L651, L652, L653 SATIN WHITE, ACCESSORIES AS REQUIRED. HEAD: COOPER L4009PX LAMP: LEDNOVATION LED - PAR38 -90 -1 XD -1 WF HEAD: COOPER L4009PX LAMP: LEDNOVATION LED - PAR38 -90 -1 XD -1 WF , ° Q 16 Q P MINI DOWNLIGHT PENDANT TRACK FLE15 /2 /A19XL 120V CLASSIC CYLINDER PENDANT HALO #L1 CYL AH 19 BL MANUUFACTURER TO LABEL FIXTURE '16WATTS MAX' 3 X1 EXIT SIGN SURFACE INCLUDED 12O/277V STENCIL SINGLE AND DOUBLE FACE LED EXIT SIGN WITH BATTERY BACK UP COOPER LIGHTING -SURE -CITES #CX7 1 70 R SD (SINGLE FACE) #CX7 2 70 R SD (DOUBLE FACE) 38 1--P• X2 EMERGENCY LIGHT SURFACE INCLUDED 120/277V SELF DIAGNOSTIC EMERGENCY LIGHT WITH BATTERY BACK UP COOPER LIGHTING -SURE CITES #CC7NCMRT -SD REGtivt J LIGHT FIXTURE SCHEDULE NOTES: CITY OFTUKVUI 2. SUBSTITUTION OF LUMINAIRES AND 3. ALL LUMINAIRES ARE TO BE HALO & COOPER -CITY LIGHTING; MAY 3 0 201 LAMPS IS NOT ALLOWED, NO FURNISHED BY GC /EC. STEVE LEHRMANN (314) 534 -1090 EXCEPTIONS. SUPPLIERS: SLEHRMANN@CITYLIGHTING.COM PERMIT CEN1 SEPARATE i t, / 1. REFER TO ARCHITECTURAL ELEVATION FOR CENTER DISPLAY TRACK LUMINAIRE MOUNTING HEIGHTS. R�QROV AL UIRED LA ER 0412755 -139 DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 Fax 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: CHECKED BY: RM 1— z O .— ' t\'t) 121 rn Z t4 4. a) C 0 ow" �3 DG == 04.3 0 m M NZ -'E • V NQC � N vv� v a NZO .moo WN = � a �� �SZW .. Q'Z =XI m H t1 m ZcVia�tj SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF wrw�rr: 1.0 LARGE CONCEPT DATE: 04 -28 -1 1 STORE NUM PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE n n n n n LIGHTING PLAN AND SCHEDULES b -2 16010 - GENERAL PROVISIONS A. Work consists of furnishing labor, materials, equipment and services required for the complete installation of electrical work shown in the Contract Documents and specified in Division 16. B. Include parts and labor, which are incidental and necessary for a complete and operable installation even though not specifically mentioned in the Contract Documents. Such items include nuts, bolts, anchors, brackets, sleeves, offsets in conduit, fittings, relays, etc. C. Arrange with landlord to provide temporary and permanent utility services as required and coordinate their installation with construction progress of this project. pay fees and costs charged by utility companies for utility services. D. Obtain temporary and permanent permits and licenses required in connection with this Division's work. Pay fees and expenses required for such permits and licenses. E. Request inspections as required by regulating agencies and /or regulations. Pay charges for inspections by regulating agencies of installations of plans and specifications. F. Include State and Local sales taxes in the bid. Keep accurate records of these taxes and furnish such records to the tenant upon request. G. Meet or exceed current applicable codes, ordinances and regulations for installations. Promptly notify the engineer, in writing, if the contract documents appear to conflict with governing codes and regulations. contractor assumes responsibility and costs for correcting non - complying work installed without notifying the engineer. H. Higher quality of workmanship and materials indicated in the Contract Documents takes precedence over that allowed in referenced codes and standards. I. The terms defined below apply to work included in Division 16. 1. The work - as defined in the 1997 AIA Document A201: The term 'Work' means the construction and services required by the Contract Documents whether completed or partially completed, and includes other labor, materials, equipment and services provided or to be provided by the Contractor to fulfill the Contractor's obligations. The Work may constitute the whole or a part of the Project.° 2. Furnish - to obtain in new condition ready for installation into the work. 3. Install - to store, set in place, connect and place into operation into the work. 4. Provide - to furnish and install. 5. Connect - to bring service to the equipment and make final attachment including necessary switches, outlets, boxes, terminations, etc. 6. Conduit - includes in addition to conduit, fittings, pull boxes, hangers and other supports and accessories related to such conduit. 7. Concealed - hidden from sight in chases, furred spaces, shafts, hung ceilings, embedded in construction, in crawl spaces or buried. 8. Exposed: not installed underground nor concealed as defined above. J. The drawing and specifications constitute the Contract Documents. An item noted in the specification or shown on the drawings is included in the Contract Documents. K. Electrical details and drawings are diagrammatic, unless specifically noted. Field verify dimensions and notify the Engineer of conflicts or discrepancies, in writing, prior to installation. L. Initiate, maintain and supervise safety precautions required with this work in accordance with the regulations of the Occupational Safety and Health Administration (OSHA) and other governing agencies. M. Do not remove or disturb asbestos containing materials from the project. Immediately stop work and notify the TENANT if asbestos containing materials are suspected. N. Before submitting a proposal on the work contemplated, examine the site of the proposed work and become thoroughly familiar with existing conditions and limitations. No extra compensation will be allowed because of misunderstanding as to the amount of work involved nor bidders lack of knowledge of existing conditions which could have been discovered or reasonably anticipated prior to bidding. 0. Conduits, pipes, ducts, lights, devices, speakers, etc., shown on the drawings as existing have been based on existing plans and may not be installed as originally shown. It is the contractors responsibility to visit the site and make determination of the existence, location and condition of such facilities prior to submitting a bid. P. Consult the drawings and specifications of Mechanical and other trades for correlating information and lay out work so that it will coordinate with other trades. Verify dimensions and conditions (i.e., finished ceiling heights, footing and foundation elevations, beam depths, etc.) with the Architectural and Structural drawings. Notify the Architect /Engineer of conflicts that CANNOT be resolved, in the field, by affected trades. Replacement of work due to lack of coordination and failure to verify existing conditions will be completed at no cost to the tenant. Q. Install conduit, cable tray, busduct, equipment, etc. allowing proper code and maintenance clearances and to avoid blocking passageways and access panels. R. Where work must be replaced due to the failure of the Contractor to verify the conditions existing on the job, such replacement must be accomplished at no cost to the tenant. This applies to shop fabricated work as well as to work fabricated in place. S. Throughout the course of the work, minor changes and adjustments to the installation may be requested by the Engineer. The Contractor shall make adjustments without additional cost to the tenant, where such adjustments are necessary to the proper installation and operation within the intent of the Contract Documents. This does not include work already completed. T. Obtain location of connection to equipment, furnished by others, from the person furnishing the equipment. U. Drawings and specifications are complementary and what is called for in either one is as binding as if called for in both. V. Include the better quality, greater quantity or higher cost for an item or arrangement where a disagreement exists in the drawings and specifications. W. Guarantee and maintain the stability of work and materials and keep same in perfect repair and condition for the period of one (1) year after the final completion of the work as evidenced by issuance of the final certificate by the Architect. X. Defects due to faulty work or materials appearing during the above mentioned period must be immediately made good by the Contractor at his own expense to the entire satisfaction of the tenant and Architect and Engineer. Include damage to the finish or the building resulting from the original defect or repairs. Y. Replace receptacles, switches, coverplates, etc., damaged by any Contractor during the course of construction. Z. Materials furnished for the temporary light and power system remain Contractors property. Remove when there is no longer need for temporary light and power or when directed by the Architect.. M. Coordinate /schedule work with the tenant to minimize disruptions. Confine interruptions to the smallest possible area. Provide temporary connections if required to provide continuity of service. BB. Inspect areas affected by the interruptions and return automatically controlled equipment, electrically operated equipment to the same operating condition prior to the interruption. CC. No fire alarm systems are to remain inactive at the end of the work day. Assure that the fire alarm system is operational at the end of each work day. Coordinate with the landlord. DD. Do not disturb normal use of the facility, except within the immediate construction area. Keep walks, driveways, entrances, etc. free and clear of equipment, material and debris. EE. Store equipment and material in a place and manner that minimizes congestion and is approved by the tenant. FF. Provide new material and equipment, unless noted otherwise. Protect equipment and material from damage, dirt and the weather. GG. Provide the highest quality workmanship and perform work only by skilled mechanics. Install material and equipment in accordance with manufacturers' recommendations, instructions and current NECA standards. HH. The tenant reserves the right to reject material or workmanship not in accordance with the specifications, before or after installation. MM. Perform cutting and patching necessary to work, unless specifically delegated to the General Contractor. Obtain special permission from the landlord before cutting structural members or finished material. Perform patching in such a manner as to leave no visible trace and return the orea affected to the condition of undisturbed work. Perform patching by workers experienced, skilled, and licensed for the particular type of work involved. Inferior work will not be accepted. NN. Patch holes left as a result of demolition of electrical equipment and devices. 00. Prevent the spread of dust, debris, and other material into adjacent areas. PP. Replace ceiling tiles damaged during installation of work, with NEW TILE. QQ. Provide minimum 4' high concrete pads for floor mounted equipment. RR. Size pad to provide a minimum 2' overlap around perimeter of equipment. SS. Refinish electrical equipment damaged during shipping and /or installation to its original condition. Remove rust; prime, and point per manufacturer's recommendations for finish equal to original. TT. Paint new raceway systems in exposed finished areas. UU. After tests have been made and accepted, clean light luminaires, panels and other equipment installed by the Contractor, leaving the entire work area in a clean and complete working order. W. Operate equipment and systems in their operating modes, to verify proper operation, prior to final inspection and Owner instructions. Notify the Engineer, in writing, that systems have been tested and are functioning and operating properly WW. Include documentation of instructions in the Operation and Maintenance Manuals. XX. Contractor is responsible for damage to electrical equipment or materials until final acceptance of the entire project by the tenant. Keep equipment clean until final acceptance of the entire project by the tenant. 16025 - DEMOLITION A. Examine the building to determine actual conditions and extent of work prior to bidding the project. Refer unclear details or conflicts to the Architect /Engineer for clarification prior to bidding the drawings. B. Verify that field measurements and circuiting arrangements are as shown on Drawings. C. Verify that abandoned wiring and equipment serve only abandoned facilities. D. Beginning of demolition means installer accepts existing conditions. E. Coordinate phasing of the demolition work with the construction sequence schedule. F. Disconnect electrical systems in walls, floors, and ceilings scheduled for removal. G. Coordinate utility service outages with landlord. H. Identify existing electrical equipment such as conduits, boxes, pullboxes, conduit bodies, and conduit racks that will need additional support due to the demolition of the existing supports. I. Provide temporary wiring and connections to maintain existing systems, including telephone and data systems, in service during construction. When work must be performed on energized equipment or circuits, use personnel experienced in such operations. J. Existing Electrical Service: Maintain existing system in service until new system is complete and ready for service. Disable system only to make switch overs and connections. Notify and obtain permission from tenant, Architect /Engineer at least 24 hours before partially or disabling system. Minimize outage duration. Make temporary connections to maintain service in areas adjacent to work area. K. Existing Fire Alarm System: Existing system shall remain in service until entire system is accepted. Disable system only to make switch overs and connections. Notify and obtain permission from landlord, Architect /Engineer and local fire service at least 24 hours before partially or completely disabling system. Minimize outage duration. Make temporary connections to maintain service in area adjacent to work area. Any additions or modifications shall be completed by landlord's designated Fire Alarm Contractor. L Existing Telephone /Data System: Maintain existing systems in service until new systems are complete and ready for service and accepted. Disable systems only to make switch overs and connections. Notify and obtain permission from landlord, Architect /Engineer and Telephone Utility Company at least 24 hours before partially or completely disabling system. Minimize outage duration. Make temporary connections to maintain service in areas adjacent to work area. M. Demolish and extend existing electrical work under and this Section, and as indicated on the Drawings. Remove, relocate, and extend existing installations to accommodate new construction. N. Provide supports for existing electrical equipment that was supported previously by demolished walls, floors, ceiling or other structures. Provide new supports from structural members not slated for demolition, prior to demolition. PP � P 0. Tenant reserves the right of first refusal to obtain material shown to be removed under this contract. Items not retained by the tenant become the property of the Contractor and must be removed from the premises. P. Demolish and remove electrical systems indicated for demolition. No portion of these systems may be abandoned in place. Q. Remove abandoned wiring to source of supply. R. Remove exposed abandoned conduit, including abandoned conduit above accessible ceiling finishes. Cut conduit in walls, floors, or columns back to a point where patching can be adequately performed and patch surfaces. S. Disconnect abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing them is abandoned and removed. Provide blank cover for abandoned outlets, which are not removed. T. Disconnect and remove abandoned panelboards and distribution equipment. U. Disconnect and remove electrical devices and equipment serving utilization equipment that has been removed. V. Disconnect and remove abandoned luminaires. Remove brackets, stems, hangers, and other accessories. W. Repair adjacent construction and finishes damaged during demolition and extension work. X. Maintain access to existing electrical installations, which remain active. Modify installation or provide access panel as appropriate. Y. Extend existing installations using materials and methods compatible with existing electrical installations, or as specified. Relocate and reroute conduit and wiring as required for conduit concealed in walls or structure being altered as part of the remodeling. Maintain continuity to devices in and downstream of remodeled work. Z. Reroute existing raceway and wiring, which is exposed due to removal of existing construction. Conceal new raceway and wiring and maintain operation. AA. If conductors are required to be removed from existing raceways, install with new conductors. BB. Provide new coverplates throughout the remodeled areas. CC. Dispose of fluorescent lamps, ballasts, and other hazardous materials in accordance with State and Federal regulations. DD. Prior to reinstallation of used equipment, thoroughly inspect each item and report defects to the Engineer /Architect in writing. Instructions for corrective measures will be given at the time and the Contract amount adjusted accordingly. If no defects are reported, the material will be included under the contractor's ONE -YEAR guarantee as outlined in Section 16010. EE. Panelboards: Clean exposed surfaces and check tightness of electrical connections. Replace damaged circuit breakers and provide closure plates for vacant positions. Provide typed circuit directory showing revised circuiting arrangement. FF. Luminaires: Remove existing luminaires for cleaning. Use mild detergent to clean exterior and interior surfaces; rinse with clean water and wipe dry. Replace lamps, ballasts, and broken electrical parts. GG. Install relocated materials and equipment as indicated on the drawings. 16050 - BASIC MATERIALS AND METHODS A. Encase conductors in a continuous raceway system. Provide pull and junction boxes as required by the NEC. Size raceway per the NEC with oversize conduits as indicated. Provide minimum 3/4' conduit for branch circuit homeruns as required by mall or landlord, provide minimum 1/2" conduit, unless, noted otherwise. B. Provide EMT for conductors unless noted otherwise. Provide concrete -tight steel compression or steel setscrew type fittings, couplings and bushings. Cast or indentor type devices are not acceptable. Fittings used in plenum applications shall be rated for such use. C. The use of EMC cable for branch circuit wiring is acceptable provided it is installed per the NEC, allowed by the mall and /or owner, and complies with all applicable local codes. It is the contractors responsibility to verify with owner's representative requirements or restrictions prior to installation. D. Provide IMC or concrete - encased PVC conduit for service entrance conductors. E. PVC conduit may be used underground or below concrete slabs. Provide coated rigid steel elbows for elbows where PVC is used. F. Provide flexible metal conduit for connections to transformers, motors and other vibrating pieces of equipment. Provide liquid -tight conduit for connections in damp or wet locations. Provide ground type fittings and grounding conductor inside flexible conduit. Adjust conduit size if required. G. Outlet boxes and junction boxes to be recessed and flush mounted. Conduits to be concealed, except in mechanical rooms. Conduit and boxes in mechanical rooms can be exposed. H. provide expansion fittings where raceway crosses building expansion joints. I. Run exposed conduit in a neat, workmanlike manner parallel to the building lines, tight to the wall and ceiling surfaces, and firmly support with conduit clamps or hangers. Provide two (2) hole mounting straps, minimum three (3) feet on center, for surface conduit mounted on walls less than six (6) feet above finished floor. Place conduits at least 8" away from hot piping and surfaces including domestic hot water lines. J. Provide galvanized code gauge steel junction and pull boxes with screw on covers of type, shape and size required to suit each installation. Provide gasketing in damp and dusty locations. Provide cast boxes in weatherproof, vapor tight and explosion proof environments. K. Provide 4" boxes throughout. Provide 3 1/2° deep boxes where installed in masonry, 2 1/2° minimum elsewhere. Provide single gang mud or tile ring for single devices. L Mount outlets boxes in exposed masonry walls with the bottom of the box on the top of the mortor joint and the vertical line of the box either on the mortar joint or on the center line of the masonry unit. Plumb and accurately align wall outlets in rows. Mount ceiling boxes symmetrical with walls, beams and /or tiles. Mounting heights indicated on the drawings are from the center of the outlet box to the finished floor directly below the outlet. Exterior heights are from inside adjacent Floor, or if no Floor, from the first floor above grade, unless noted otherwise. M. Coordinate the location of outlets with architectural and mechanical drawings before installation. Coordinate door swings in the field before locating switches. N. Provide new wiring devices in each outlet indicated on the drawings. Provide devices from one manufacturer. Color to match adjacent surface. 0. Approved toggle switch manufacturers /model numbers: Manufacturer 20A/120 -277V Wall Switches 1 -pole 1 -pole w /Pilot 2 -pole 3 -way 4 -way Keyed 1 -pole Mom. Contact Cooper 2221 2221PL 2222 2223 2224 2221L 1995 Hubbell HBL1221 HBL1221PL HBL1222 HBL1223 HBL1224 HBL1221L HBL1557 P &S PS2OAC1 PS2OAC1 -RPL PS2OAC2 PS2OAC3 PS2OAC4 PS2OAC1 -L 1251 Leviton 1221 -2 1221 -2PL 1222 -2 1223 -2 1224 -2 1221 -2L 1257 P. Approved standard receptacle manufacturers /model numbers: Manufacturer 20A/125V Standard Receptacles Simplex Duplex GFI IG 1VSS Tamper Resistant Cooper 5361 5362 XGF20 IG5362 5362S TR8300 Hubbell HBL5361 HBL5362 GFR5352A IG5362 HBL5360SA HBL8300SGA P 8cS 5361 5362A or PT5362A 2094 IG6300 8300SP TR63H Leviton 5361 5362 8899 5362 -IG 7380 8300 -SG *PROVIDE THE CORRESPONDING HOSPITAL GRADE DEVICE WHEN THIS DEVICE IS USED. Q. Provide new coverplates over boxes with the following specifications: finished areas and unfinished areas. Provide smooth plastic covers, color to match adjacent surface or as selected by the architect. Provide appropriate covers over special purpose receptacles. Provide new weatherproof coverplates for outlets and switches as indicated on the Drawings and for exterior devices. R. Provide wire and cable with insulation voltage rating equal to or greater than the applied system voltage. Provide solid or stranded copper conductors with type THWN, THHN, or XHHN insulation for No. 12 AWG and No. 10 AWG conductors. Provide stranded copper conductors with type THWN, THHN, or XHHW insulation for No. 8 AWG and larger conductors. Provide minimum No. 12 AWG conductor size, unless noted otherwise. Use the minimum conductor size when no size is indicated. conductors to be color -coded as follows;120 /208 volt systems -phase a(black), phase b(red), phase c(blue), neUtral(white). 277/480 volt systems -phase a(brown), phase b(orange), phase c(yellow), neutral(white with tracer or gray). grounding system (green). S. Prior to turning the building over to the Owner turn on equipment in the building including lighting and with a multimeter, read the current drawn on each hot leg of feeder supplying each distribution panel. If the current in any one leg varies more than 5% (plus or minus) from the arithmetic average of the current in the hot legs, reconnect the branch circuits to obtain a balanced loading. T. Provide fire barriers around conduit, pipe, tubing, bus ducts and cables passing through smoke and fire rated floors and walls. Provide CP 25, 303 and PSS7904 Series by 3M, or "Flame- Safe" system by Thomas and Betts Corp for fire seals. Provide HILTI CP -617 firestop putty pad around electrical outlet boxes located in fire rated walls. U. Make connections to motors and equipment furnished and set in place by others. Provide starters, manual controls and auxiliary equipment where indicated in schedules and specified herein. Provide disconnect switches as indicated in schedules, specified herein and required by Code. 16400 - POWER DISTRIBUTION, A. Retail Metering Center. 1. Provide meter sections containing meter quantities as indicated on the Drawings. 2. Provide meter branches rated 200 amp maximum. 3. Provide 3 phase, 4 wire meters for use on 120/208 VOLT AND 277/480 volt, 3 phase, 4 wire systems with seven (7) jaw meter sockets. Meters furnished by the utility company. 4. Mount the above components as shown on the Drawings in a UL approved and labeled, NEMA Class 1 floor mounted steel enclosure. Enclosure to be constructed to finished steel cleaned, primed, and painted with baked enamel finish prior to shipment to the job site. B. Provide fuses of the following types (Bussmann used as reference): 1. 600 amps and above: Time -delay type designed to hold 500% of rated current for a minimum of 4 seconds and clear 20 times current in 0.01 seconds or less with interrupting ratings of 200,000 amperes RMS symmetrical and peak let- through current and energy let- through values established by U.L. Standard for Class L fuses. Provide KRP -C fuses. 2. Below 600 Amps: Dual- Element construction with interrupting rating of 200,000 amperes RMS symmetrical and peak let -thru current established by U.L. Standard for Class RK -1 fuses. Provide LPN -RK /LPS -RK. 3. Motor circuits: Protect individual motor circuits with full load ampere rating (FLA) of 400 amperes or less with dual - element time -delay fuses. Provide LPN -RK /LPS -RK. Protect larger horsepower motors with time -delay fuses. Provide KRP -C fuses. Provide U.L. Class RK1, dual - element time -delay for other motors,. 4. Motor Controllers: Protect NEMA and IEC style motor controllers with dual - element, time -delay fuses to provide Type 2 coordination for the controller. Provide LPS -RK fuses. 5. Protect circuit breaker panels with U.L. Class RK1, Class L fuses. Provide LPN -RK, LPS -RK, or KRP -C fuses. 6. Provide fuse sizes as indicated on the Drawings. 7. Acceptable manufacturers: BussmaNn, Ferraz - Shawmut or Littelfuse or pre- approved equal. C. Provide lighting and appliance panelboard assemblies adhering to the following specifications: 1. Enclosures constructed of galvanized sheet steel of thickness as required by Code, with enameled steel trim, distributed busing, hinged steel doors latches, locks and adjustable trim clamps. Provide NEMA 3R enclosures for exterior locations. 2. Provide welded metal frame with typed circuit directory for each panel. 3. Compliant to the following standards: UL 50, UL 67, NEMA PB -1, NFPA 70 and Fed. Spec W- P -115C , UL 489, NEMA AB -1, Fed. Spec. W- C- 375B /GEN, IEC 157 -1 and BS 4752. 4. Compliant to Article 408 of the NEC: 'Lighting and Appliance panelboard °. Maximum of 42 poles per panelboard assembly. 5. Provide panelboards with interrupting ratings as shown on the plans. 6. Provide 240 volt AC rated panelboards for 208/120 and 240 volt AC systems. Provide 480/277 volt rated panelboards for 480/277 volt systems. 7. Provide tin - plated copper bus bars or tin - plated aluminum bus bars. 8. Provide proper lugs (75 C. minimum temperature rating) and gutter space for cable size indicated on the plans. 9. Provide panels by the same manufacturer. 10. Provide screw mounted, engraved namplates for each panelboard. 11. Provide molded case, non - adjustable, thermal- magnetic, quick -make, quick- break, bolt -on type circuit breakers. Refer to the schedules on the plans for sizes and quantities. 12. Provide muli -pole breakers where indicated on the schedules. Handle ties on single pole breakers are not acceptable. 13. Provide secondary ground bus in each 208/120V panel board. 14. Acceptable Manufacturers: A. 240 Volt 1. Square D type NQOD 2. Siemens type S1 series 3. Cutler Hammer Pow -R -line 1 a series 4. General Electric AQ series 5. Pre - approved equal B. 480 volt 1. Squared D type NF 2. Siemens type S2 series 3. Cutler Hammer Pow -R -line 2a series 4. General Electric AE series 5. Pre - approved equal D. Provide panel identification label for each panel including panel name, voltage and feeder. For example: 'HDP -1 -1, 480/277 V, 3, 4 wire, 2 °C - 4 # 4/0 THWN °. E. Mount panelboards and cabinets to building structure or interior wall construction. Mount independent of conduit and raceways entering boxes. F. Mount panelboards with cabinet top at 78" above finished floor. G. Provide 3/4 "empty conduits from each flush mounted panelboard. When the floor is on grade, provide three (3) conduits into the ceiling cavity above. When the floor has accessible space below, provide two (2) conduits into the ceiling space above and two (2) conduits into the accessible space below the floor. Ends shall be capped and shall be tagged at both ends with permanent tags. H. Provide a circuit directory completely typed on the interior of each panel door. I. Equipment Ground - Solidly ground conduit systems, switch boxes, cabinets, motor frames, switchgear, transformers, and other permanently installed equipment in accordance with the latest edition of the National Electrical Code to form a continuous, permanent and effective grounding system. Bond expansion joints and metal raceway sections. Provide ground conductor as indicated on the drawings or specified herein. J. When connecting single phase circuits and equipment to a three (3) phase system, distribute the loads on the phases to achieve an approximately balanced loading of the three -phase system. 16430 - MOTOR CONTROL A. Provide "on -off" toggle type manual starter switch with thermal overload protection for single phase motors, where manual control is indicated. Provide each switch with a red pilot light indicating when motor is on. B. Provide full voltage type starters and thermal overload protection and external manual reset for THREE -PHASE motors, unless indicated otherwise. Equip each starter with 120 volt coil, control power transformer, secondary fuse block and fuses, auxiliary contacts as indicated, red "ON" pilot light, and "HAND - OFF -AUTO" control switch. Provide combination starter /disconnect when indicated on the plans. Acceptable Manufacturers for magnetic starters: Allen - Bradley Bull. 509 &512, Square D Class 8536, Cutler Hammer, General Electric, ITE /Siemens equivalent or pre- approved equal. C. Provide manual motor starting switch or Type "SS" fused disconnect adjacent to each 120 VAC single phase motor located out of sight and /or in excess of 50' -0" from the controller, or as indicated on the Drawings.. D. Inter lock rooftop hvac unit fan starter with duct detector to shut down fan upon detector activation. 16460 - TRANSFORMERS A. Provide ventilated, indoor, dry-type distribution transformer with the capacity and voltage characteristics indicated on the degrees Transformers 15 KVA and above will be designed to operate with a 115 g rees C. Temperature rise above 40 degrees C. ambient. Provide insulating materials for a 220 degrees C. insulation system. B. Provide transformers meeting or exceeding NEMA class 1 efficiency requirements as required in the Local Energy Code. C. Provide voltage taps as indicated below: 1. Provide two 5% FCBN taps for single and 3 phase transformers 9 KVA and below. 2. Provide two 2 1/2% FCBN and two 2 1/2% FCAN taps for 3 phase transformers 15 KVA and below. 3. Provide four 2 1/2% FCBN and two 2 1/2% FCAN taps for 3 phase transformers above 15 KVA. D. Provide sound ratings not exceeding the following levels: 1. 0 to 15 KVA, 40 Decibels. 2. 15 to 50 KVA, 45 Decibels. 3. 50 to 150 KVA, 50 Decibels. 4. 150 KVA or Greater, 50 Decibels. E. Provide continuous copper or aluminum coil conductors with brazed or welded terminations. F. Isolate transformer core and coil from the enclosure using vibration - absorbing mounts. G. Provide transformers 75 KVA or less with enclosures suitable for wall, floor or trapeze mounting. Provide transformer larger than 75 KVA with enclosures suitable for floor or trapeze mounting. H. Provide maximum case temperatures not exceeding a 35C temperature rise above a 40 degree C ambient. I. Acceptable manufacturers: Cutler Hammer, General Electric, Sorge!, Hevi -Duty Jefferson Electric or pre- approved equal. 16500 - LIGHTING A. Comply with NEC as applicable to the installation and construction of luminaires. B. Comply with UBC as applicable to the installation and construction of luminaires. C. Provide luminaires that are listed and labeled by U.L. or another nationally recognized testing laboratory for the application. D. Provide lamp ballasts that comply with Certified Ballast Manufacturers Association standards and carry the CBM label. E. Comply with local, state and federal energy codes. F. Provide luminaires with lamps, for each outlet shown on the Drawings and as specified herein. See luminaires list on the plan. G. Provide fluorescent lamp ballasts with the following minimum specifications 1. Disconnecting means on the line side of the ballast to disconnect hot and neutral conductors, as required after January 1, 2008 by the 2005 NEC Article 410.73G. Provide either factory- insstalled disconnecting means, or provide field - installed disconnect inside the ballast channel. Approved field - installed disconnect 1) WAGO 873 2) TYCO /AMP LIGHT -N -LOK CPGI series 3) T & B STA -KON LD2 /LD3 series 2. Provide U.L. listed and labeled, C.B.M. approved ballasts. 3. Programmed Rapid Start technology to ensure longest lamp life. 4. T8 Only: Parallel -wired operation to ensure light output from one ballast even with one or two lamps extinguished. 5. Compact Fluorescent only: Series wired lamps for multiple lamp configurations, and plug -in lead connectors for lamp leads 6. Class 'P" rated with thermally activated automatic resetting protective devices sealed in housing. 7. Current Crest Factor: 1.7 or less on 60 Hz modulated current. 8. Comply with FCC Rules Part 18 requirements governing electromagnetic and radio frequency interference 9. Complies with IEEE 587 for withstanding line transients, voltage regulation ± 10 percent, light regulation ± 10 percent. 10. Ballast Factor: 0.88 or higher. 11. Power Factor: greater than 95 percent 12. Sound rating: A' 13. Minimum 5 year warranty including $10 /ballast labor 14. Total Harmonic Distortion: <20% , but greater than 10 %. 15. End -of -life lamp sensing for Compact Fluorescent ballasts. H. Approved manufacturers - T8 electronic ballasts 1. Advance Centium Program Rapid Start series 2. Universal Lighting Technologies Triad AccuStart series I. Approved manufacturers - Compact Fluorescent 1. Motorola Gold edition 2. Robertson 3. Osram Quicktronic series 4. Universal Lighting Technologies J. Provide inside frosted lamps with brass base, rated 130 volts for incandescent lamps, unless noted otherwise. 1. Approved manufacturers a. Philips b. General Electric c. Osram /Sylvania d. Pre - approved equal K. Provide minimum 85 CRI for fluorescent lamps. Provide 4100K color lamps for fluorescent luminaires. 1. Provide F032, F025 and F017 T8 lamps for 4', 3' and 2' luminaires, respectively, unless noted otherwise. 2. Approved manufacturers: a. GE Starcoat SPX b. Phillips TL80 c. Osram Sylvania Octron 800XP L Provide solid state, slid -type dimmers suitable for mounting behind a standard depth faceplate and for operation on common neutral circuits. 1. Provide 600 watts capacity per dimmer unless noted otherwise on the plans. 2. Acceptable Manufacturers: Lutron Nova T -star series or pre - approved equal. M. Solid State type Time Switches. 1. Provide solid state, programmable 24 hour or 7 -day, electric time switch with FOUR (4) SPST contact rated 20A at 240 volts. Provide long life lithium battery backup to maintain time and memory setting during a power outage. 2. Provide astronomical control. 3. Acceptable manufacturers a. Paragon EC7000 series b. Tork Model D100 series c. pre- approved equal N. Provide lighting contactors that adhere to the following specifications, where lighting control relays or contactors are called out on the drawings: 1. Electrically held relay, 30 amp ballast rated, 20 amps tungsten rated @ 277 volts 2. 2 pole minimum (refer to plans for required poles) 3. Installed in NEMA 1 enclosure indoors, NEMA 3R enclosure outdoors. 4. Coil Voltage: 24VAC. 5. Coordinate accessories with Division 15's EMS Contractor. 6. Approved Manufacturers: a. Square D Class 8903, Type 'L' series b. ASCO 917 series c. Siemens type CLM d. pre- approved equal 0. Provide photoelectric switch control with a set of SPST contacts rated at 120 volt AC, 1800VA in a NEMA 3R enclosure. 1. UL listed. 2. Approved manufacturers: a. Paragon CW /210 series b. Tork 2101 series 3. If used as a sensor input to the lighting control system, provide photocell controllers fully - compatible with the lighting control panels used on this project. Refer to section 16915. P. Provide hangers, rods, mounting brackets, supports, frames, etc. for proper and safe luminaire installation. Install luminaires in accordance with manufacturers' recommendations and instructions. Q. Provide luminaires complete with auxiliaries required for proper, safe and distortion free installation in the various ceiling constructions in which they appear. Coordinate ceiling types with the Architectural drawings and provide compatible luminaires. R. Provide felt or fiberglass gaskets on incandescent luminaires where necessary to prevent light leakage at the ceiling line. S. Securely support LUMINAIRES directly from building structural members or 11/2' or larger steel ceiling framing channels. Use steel channel equivalent to Kindorf #6029 where it is necessary to span the building structural members for fixture support. Wood supporting members or wires will not be acceptable. Provide minimum 1/' diameter lag screws when anchoring into wood structural members. Penetrate wood structural members a minimum of 2' with screws. Provide steel or lead, expandable type, anchors with minimum penetration of 11/2' when anchoring to concrete. When installing luminaires in a seismic zone, secure to meet requirements. T. DO NOT suspend conduit, light luminaires, or ballasts from metal roof deck or from the ceiling suspension wires. Support lay -in luminaires independent of the ceiling support system. Provide fastening clips on each corner of each luminaire in accordance with the UBC and State Building codes. U. Equip luminaires using conduit stems with ball swivel hangers. In finished areas, provide canopies for the hangers. hanger er lu luminaire plus one per row. Support V. Support surface mounted fluorescent luminaires with a minimum of one per m p p pp individual luminaires with a minimum of two hangers. Attach hangers to the ceiling grid per code. W. Support suspended fluorescent luminaires with a minimum of two fixture hangers. Attach each hangar to a dedicated anchor. Locate hangars directly above the corners of the luminaires. X. Where master /slave or inboard /outboard switching is indicated, provide tandem -wired ballasts between luminaires as required by the local Energy Code. Y. Wire recessed lay -in luminaires with 6 feet of flexible metal conduit with Type "THHN /THWN" wire to the outlet box. Provide grounding type connectors for conduit and cable. Z. Provide outlet boxes adjacent to each recessed Iluminaire outlet in suspended ceilings to permit each luminaire to be adjusted to fit ceiling pattern and to permit "Feed Through" wiring. M. At the time of substantial completion, luminaires must be installed and lamped with new lamps. Install luminaires complete with lenses, diffusers, reflectors, louvers and other required accessories. BB. Replace damaged reflectors, diffusers, louvers or other components at no expense to the Owner. CC. Clean luminaires free of dust, finger prints, paint, etc.. DD. Perform aiming and adjustment of luminaires in accordance with instructions issued by the Engineer /tenant. Adjust directional type luminaires (interior and exterior) after dark under the direction of the Architect, Engineer, and /or tenant. EE. Replace defective ballasts within the guarantee period at no cost to the tenant. FF. Install dimmers where indicated on the Drawings. 1. Where dimmers are shown ganged with other dimmers and /or other devices, size outlet such that dimmers will not be underated. GG. Install photocell(s) per manufacturer's recommendations. 1. Aim away from artificial light sources such as street lights or security lights. 2. Seal penetrations through roof or penthouse wall. HH. Install time switches adjacent to the source lighting panel, unless specifically located elsewhere on the plans. 1. Set longitude and latitude settings and the astronomical time. 2. Provide time settings per the tenant's direction. II. Provide "nameplates" for contactors and time switches. Label contactors and time switches to indicate load served (e.g., canopy lights, store sign, etc.) 16535 - EMERGENCY UGHTING A. Provide automatic battery powered lighting units as indicated on the drawings. B. Provide emergency lighting as shown on the plans to illuminate the egress corridors and other required areas. Refer to the luminaire schedule on the drawings for types. C. Provide an intensity of not less than 1.0 footcandle at the floor level along the path of egress. D. Provide an exit light at each exit and along the egress path as required. E. Connect emergency lights to the unswitched branch circuit(s) in the area, provide handle -lock device for that circuit. 16741 - VOICE AND DATA RACEWAY A. A. Provide 4' square boxes for each recessed outlet box. Provide 31,x' deep masonry type in recessed masonry installations. Provide mud or tile ring as required for boxes. B. Provide the following in accessible ceilings as follows: Provide an empty box with (1) 3/4' conduit stubbed into ceiling space for each telephone outlet indicated on the drawings; Provide an empty box with (2) 3/4' conduit stubbed into ceiling space for each data, voice /data or fiber optic outlet indicated on the drawings. C. Provide the following in inaccessible ceilings (plaster, spline, gypsum, security grid, plank, etc.) as follows: Provide an empty box with (1) 3/4° conduit routed to the nearest telephone backboard location for each telephone outlet, unless noted otherwise on the plans; Provide an empty box with (2) 3/4' conduit routed to the nearest communications closet backboard location for each data, voice /data, or fiber optic outlet, unless noted otherwise on the plans. 3/4' EMPTY CONDUIT FROM ABOVE CEILING IN SALES FLOOR CONCEALED DOWN WALL TO FLUSH MOUNTED 2 -GANG JUNCTION BOX WITH STAINLESS STEEL COVER. FIELD VERIFY BEST MOUNTING LOCATION WITH BEST BUY SECURITY CONTRACTOR. SECURITY WIRING, HARDWARE AND CONNECTIONS PROVIDED BY SECURITY CONTRACTOR. J BOX ELECTRICAL CONTRACTOR SHALL 1 PROVIDE CONCEALED 3/4' EMPTY CONDUIT FROM FLUSH MOUNTED 2 -GANG JUNCTION BOX DOWN WALL TO DOOR FRAME FOR SECURITY DOOR CONTACT WIRING. SECURITY DOOR CONTACTS FLOOR 2 Entrance Door Detail TYP. X MOD. SCALE: N.T.S. (2) LOOP START PHONE LINES (2) RJ 31X JACKS PROVIDED BY PHONE COMPANY. (1) 110 VAC OUTLET ON DEDICATED CIRCUIT. i r CONDUIT PANEL 18'X18' PANEL SHOULD BE MOUNTED ON A 20"X20' PIECE OF PLYWOOD FLOOR KEYPAD BACK BOX I PROVIDED BY CSSG I __i_ii 8.2'X4.6' STUB NEAR BOTTOM OF BAR JOIST BUSHED I I I tSs\_ CONCEALED I CONDUIT 1 0412755 -139 DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering DRAWN BY: Ti_ CHECKED BY: RM 4 Alarm Panel Detail TYP. X MOD. SCALE: N.T.S. 5 Security Keypad Detail TYP. x MOD. SCALE: N.T.S. 111M...11V/A1All■ A I I I CONCEAL I 3/4" EMPTY CONDUIT - I I I SURFACE MOUNTED 4" x 4" BOX w /COVER FOR MOTION DETECTOR DOT 0 90" STUB NEAR BOTTOM OF BAR JOIST BUSH END. SURFACE MOUNTED 4" x 4" BOX w /COVER FOR SECURITY DOOR CONTACT 6 Ext. Single Door Detail TYP. X MOD. SCALE: N.T.S. Not Used TYP. MOD. SCALE: N.T.S. NOTE: PHONE BOARD AND COMPONENTS TO BE INSTALLED DURING FIRST WEEK OF CONSTRUCTION. (INCLUDING PERMANENT POWER, GROUND AND CONDUIT FOR TELCO) EXISTING ACT NOTE: NO SURFACE MOUNTED CONDUIT ON PHONE BOARD TO OUTLET UNLESS FED FROM BOTTOM. E R V R El:: 2" (UNLESS NOTED OTHERWISE) CONDUIT FROM 7' -2" TO DECK WITH 90 SWEEP AT DECK FOR TELECOMM ENTRANCE CABLE. NYLON BUSHINGS AT BOTH ENDS. #6AWG GROUND WIRE. EC TO MAKE CONNECTION TO BUS BAR. BUS BAR PROVIDED BY BBM I.S. 24" X 24" X 1/2 FRT PLYWD FOR TELECOMM - EQUIP. 00 00 (1) DOUBLE DUPLEX OUTLET ON DEDICATED 20 AMP CIRCUIT FOR SERVER CAB. SERVER IN FRONT. STOCK (1) DOUBLE DUPLEX OUTLET ON DEDICATED 20 AMP CIRCUIT FOR SERVER CAB. 20" x 20" x 1/2" PLYWD BACKER FOR SECURITY PANEL. BOT 0 5' -0" AFF, 24" X 24" x 1/2" PLYWD PHONE BD OVER SERVER. BOT © 5' -0" AFF. SERVER. RECEIvtU CITY OF TUKVVILA MAY 3 0 2012 ERMNT CENTER 1 Electrical Specification SCALE: N.T.S. 8 Typical Phone Board Detail TYP. X MOD. SCALE: N.T.S. T !" Zt°�wo R N co N v • JIN03o 0 at " E 0•'i z - vw to = WNd I• I- Z o)zoX ZN2atai. iW SQ. FT. CALCS RETAIL: 1,170 SF TOTAL: 1,682 SF concur: 1.0 LARGE CONCEPT DATE: 04 -28 -11 STORE NUM # ## PERMIT SET ISSUE DATE: 05 -23 -12 REV. DATE n n n 0 n SCALE: AS NOTED ELECTRICAL SPECIFICATIONS & DETAILS E -3