HomeMy WebLinkAboutPermit D12-190 - WESTFIELD SOUTHCENTER MALL - CHICKEN NOW - REMODELCHICKEN NOW 2600 SOUThCENTER MALL FC-11 D12 -190 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Project Name: CHICKEN NOW Permit Number: D12 -190 Issue Date: 07/09/2012 Permit Expires On: 01/05/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MOSAD ELEWA Address: 6601 MEMORIAL HY, SUITE 204 , TAMPA FL 33615 Contractor: Name: HOLMBERG COMPANY Address: PO BOX 249 , KIRKLAND WA 98083 Contractor License No: HOLMBC *066ME Lender: Name: Address: Phone: 813- 245 -6554 Phone: 425 822 -2233 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: REMODELING OF EXISTING FOOD COURT SPACE (FC -11) IN MALL, STORE FRONT REMODELING. NEW FINISHES & RELOCATING SOME COOKING EQUIPMENT. Value of Construction: $50,000.00 Fees Collected: $1,583.80 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -190 Printed: 07 -09 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Start Time: N Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am author' - _ to sign and obtain this development permit and agree to the conditions attached to this permit. Signatur-. Date: 1- 9 - Print Name: C6`t e Ni' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. doc: IBC -7110 D12 -190 Printed: 07 -09 -2012 7: All plumbing and gas piping work shall bilspected and approved under a separate perrissued by the City of Tukwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Re- location of the kitchen hood and cooking equipment requires a separate mechanical permit and will be reviewed under that permit. 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Maintain fire extinguisher coverage throughout. 18: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 19: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 20: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 21: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2328) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 23: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 24: Post address on storefront per approved Westfield standards. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 26: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D12 -190 Printed: 07 -09 -2012 27: These plans were reviewed by Inspect 1. If you have any questions, please call Tu (206)575 -4407. Fire Prevention Bureau at doc: IBC -7/10 D12 -190 Printed: 07 -09 -2012 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA..clov • Building Permit No. ti)-- ( l 0 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 9400 King Co Assessor's Tax No.: Site Address: % 4 50114 s44'I6It / 5CATTI _A Suite Number: FC fl Floor: 2.AV Tenant Name: Gi71G ...01 n!o(,J PROPERTY OWNER Name: 1564 5AgA5 Address: 3(21 x(, AKPG Ul U) 90 Aver 4 I%t City: --rArA.pA, State: pi.„ Zip: 33618 CONTACT PERSON — person receiving all project communication Name: M 05A9 a !E (I*JA- Address: 6601 MEA141 -i,k■ I-I4 5.K- 2434 City: TAtA1aR State: p(. Zip :3 %15 Phone: 8133— 245 - (0554 Fax: tool, 24$'(0554 Email: isnosApe,6404. G'M' �% •• GENERAL CONTRACTOR INFORMATION Company Name: N 1 Architect Name:' ,4 J l y 14 i k 1T Address: 4410 l!J , M etr< 5E AV5, City: l'AMek State: ft, Zip:53( Address: Email: (p(ro @ t':iCpAl2.7 d)6T City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\ Applications \Form- Applications On Line \21111 Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh New Tenant: ❑ Yes 2nNo ARCHITECT OF RECORD Company Name: N 1 Architect Name:' ,4 J l y 14 i k 1T Address: 4410 l!J , M etr< 5E AV5, City: l'AMek State: ft, Zip:53( Phone: 513 -333 2111 Fax: 813-2m-3332_ Email: (p(ro @ t':iCpAl2.7 d)6T ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: bei> Page 1 of 4 • • BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ SDI 060 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): '�RE� Of�Q *Pel -;)Jy dF 6"AIS -h /G root? au9-T 54ACE N/14414 S Nh t . Nib W/^/'Soos- gELac.4 -1,%J4 govvue. Gde OgI rti' Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below fir PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: t,g Sprinklers s Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 13( No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applicalions\Fornss- Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per 1St Floor p di� �P 404 'J ,� /IBC /V rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck fir PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: t,g Sprinklers s Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 13( No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applicalions\Fornss- Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT . RIZED AGEN Signature: Print Name: Mailing Address: 664I M6 or i A(. i-hA/1 204 H:\ Applications \Forth- Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -11. docx Revised: August 2011 bh Date: 12- Day Telephone: 813.2g6,4554 City State Zip Page 4 of 4 • J�.`Nt�A wq City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.ov RECEIPT Parcel No.: 9202470010 Permit Number: D12 -190 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/05/2012 Applicant: CHICKEN NOW Issue Date: Receipt No.: R12 -02072 Initials: User ID: Payee: WER 1655 Payment Amount: $961.65 Payment Date: 07/09/2012 02:25 PM Balance: $0.00 HOLMBERG COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 53523 961.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $961.65 957.15 4.50 doc: Receiot -06 Printed: 07 -09 -2012 • • J�W��A wq City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12 -190 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/05/2012 Applicant: CHICKEN NOW Issue Date: Receipt No.: R12 -01785 Initials: User ID: Payee: WER 1655 Payment Amount: $622.15 Payment Date: 06/05/2012 04:11 PM Balance: $961.65 MAK, WARREN KWAN FUNG TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2225 622.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 622.15 Total: $622.15 doc: Receiot -06 Printed: 06 -05 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 t (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 _Dr2 -r9 o Project: �� ` , i l i � opt. . j C,A !V tom/ Type! f , kJ AA .. I iA t=, �• i.3J , Address. C { / Date Called: Special Instructions: lJ Date Wanted: a-! i ■ Lo _ r P Requester: Phone No: CO CS— .03. —23:3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ( )(c__ r ' �' s . p_.er Pk.07' • Inspeo,or: Dater v" 1 ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION`:.zC 6300 Southcenter Blvd., #100, Tukwila. WA 98188 .(206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: ` ✓�C_ C t 6r v d Type of ( n: 61 A- . f " Address: Date Called: Special Instructions: / Date Wanted: .• g a.m. -,---. :: Requester: Phone No Approved per applicable codes. El Corrections required prior to approval.' COMMENTS: Inspector n n REINSPECTION FEE REQUIRED. Prior to next inspection;,feemustbe: paid at 6300 Southcenter Blvd., Suite 100. Call to schedule , INSPECTION RECORD Retain a copy with permit - INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: . U) h G F i/ /V o Type of inspection: ; l �A-*/(t (/t. (, Address_: /( ,��/ Date Called: Special Instructions: ' -- t r fel f -- ` v� (Q %P A' �D ,s r f Date Wanted7_23 _ r m Requester: r P6(2.....-1-4 M Z., — t 3 Phone No: 1niS- 4432353 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 646:4‘ P6 —peAd Ins ,actor: Al fj�app,\\\\ VJ _ I\ 1-7 REINSPECTION FEE REQUIRED Prior to paid at 6300 Southcenter Blvd., Suite 100. Date: next inspection, fee must be Call to schedule reinspection. dl INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit \2- - - \\o`k PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: , Type of (Inspection: , II—u \r‘ o SR t ,..,,k1-e_c- \,..) k)-"k., ,c.\ cAl,....A. ...... Address: a6 sic , ,M .,k i Suite #: Lv4 Contact Person: ' Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. 'COMMENTS:. Sprinklers: 116 5 II—u \r‘ o SR t ,..,,k1-e_c- \,..) k)-"k., ,c.\ cAl,....A. ...... F‘k... A \Qc VA"■ 61t . Monitor: 1 Pre -Fire: Permits: Occupancy Type: 1S Needs Shift Inspection: O Sprinklers: 116 5 Fire Alarm: `-(QJ Hood & Duct: `(cS Monitor: G---. Pre -Fire: Permits: Occupancy Type: 1S Inspector: ?` S Date: €8k \Z Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call.to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Food -:and .FacilitiesProgra:m 401 Fifth Avenue; Suite 1100 Seattle;; WA 98104 1818 . .. 206296- 4632:1:Fax 2064296 -0188 TTY: Rela.Y ,.711:. ww.w kingcounty.gov /health.:;;'; :,;::,:: 12 /2 -iww public-RegthiLti Seattle & King County. June 28, 2012 Transmitted via electronic mail and US Mail Mosad Elewa 6601 Memorial Hwy #204 Tampa, FL 33615 RE: Plans and Specifications for: Remodel of an existing facility Chicken Now at 633 Southcenter #FC11, Tukwila, WA 98188 SR1223436 P/E 6703 (Risk 3) PR0077500 Dear Mosad, The plans and specifications for the above remodel project have been reviewed and, in accordance with the provisions of Title 5, the Code of the King County Board of Health Rules and Regulations 05 -06 (The Food Code) are hereby APPROVED and subject to the following conditions: • Per the email response that I received on 6/28/12, Chicken Now will be closed for two (2) weeks to complete the remodel project and that all perishable items will be discarded prior to beginning the work. • No changes shall be made without Health Department approval. This approval letter only addresses the equipment, plumbing fixture locations and finishes. It does not include piping, grease traps, back flow prevention or other piping systems. Your establishment has been assigned the following plan review service number SR1223436. Please use this SR# in all future contact with us. As required in The Food Code, upon completion of the construction and before opening for business, the food service establishment operator /owner shall: 1. Obtain a preoperational inspection approval. Contact Diane Agasid (206 -296 -9750) at least one week in advance to schedule a preoperational inspection. Be sure all other inspections (plumbing, building, etc.) are done before you call the Health Department for an inspection. Please refer to the enclosed Preoperational Checklist for more information. Your application for a food service establishment permit from Public Health Seattle & King County may be approved during this inspection. However, it is the responsibility of the food service establishment operator /owner to obtain all necessary permits and approvals from other agencies. Operating the establishment without these required permits or approvals may subject the operator /owner to legal action by the appropriate agencies. If the establishment is opened without the Health Department preoperational inspection, it may be subject to closure. Failed preoperational inspections will require a $402.00 fee ( +$201.00/hr after 2 hours) for a repeat inspection. Please be aware that additional hourly fees will be charged if the total plan review and preoperational inspection goes beyond the base three (3) hours for this remodel project. An invoice will be sent to you after the preoperational inspection and must be paid immediately. RECEIVED JUL 27 2012 PST EE4TER Contact your local building department or water district if pre - treatment facilities are required when wastewater contains more than 100 parts per million by weight of fat, oil or grease of animal, vegetable or mineral petroleum origin. If you have any questions, please don't hesitate to contact me. Thank you for your compliance in this matter and 1 look forward to seeing you soon. Diane Agasid, R.S. Food and Facilities Plan Reviewer DA Enclosures cc: David Wu, Owner, Chicken Now RECEIVED JUL 27 2012 PERMIT CENTER • PEWIT PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -190 DATE: 06 -05 -12 PROJECT NAME: CHICKEN NOW SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -11 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BGi�dirta Division t(2— AVIA NC 194- 1)' Fire Prevention D k .1'L Public Works /v//1- Planning ivision Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06-07 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route, Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-05-12 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople Pr,er Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLMBERG COMPANY UBI No. 174003387 Phone 4258222233 Status Active Address 1128 8Th Street License No. HOLMBC'066ME Suite /Apt. License Type Construction Contractor City Kirkland Effective Date 7/5/1994 State WA Expiration Date 9/1/2013 Zip 98033 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLMBPH2300AHOLMBERG PLUMBING /HEATING INC Construction Contractor Plumbing Unused 9/1/1977 9/1/1994 Archived Business Owner Information Name Role Effective Date Expiration Date VARRIANO , JON S Cancel Date 01/01/1980 Bond Amount HOLMBERG, KANDICE K 8 01/01/1980 1959086 WHITE, JEFF K President 09/01/2006 WHITE, DIANA Secretary 09/01/2006 INS CO OF THE WEST WHITE, DIANA Treasurer 09/01/2006 09/01/2011 HOLMBERG, A PHER Vice President 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 HANOVER INSURANCE COMPANY THE 1959086 09/01/2011 Until Cancelled $12,000.0007/18 /2011 7 INS CO OF THE WEST 1349930 07/06/2001 Until Cancelled 09/01/2011 $12,000.00 08/16 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 PHOENIX INS CO DTC06159M235PHX1009/01/2009 09/01/2012 $1,000,000.0008 /08/2011 18 0010 CAS INS BK0053104325 09/01/2005 09/01/2009 $1,000,000.00 08/21/2008 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/09/2012 COOS INDEX , \� ���; �;; , 'X REMODEUNG DRAWING INDEX C-I *. -I A -2 A MOP- COVER SHEET 1 k cEIUN PION[ OTES EQUIP• P�.r S�.r M S, FINISH Ste• STO �A & SECTIONE S® �� MECIC CA , N PLUM ING MOD�CA'ION GO EVIE® OFD �� CO FOR PROVED JUN 2 2 2012 PL. U City Of u BUILDING ila VISION BUILDING CODE: • I.B.C. (2009) WITH WASHINGTON STATE AMENDMENTS • N.E.C. (2006) WITH WASHINGTON STATE AMENDMENTS • I.M.C. (2009) WITH WASHINGTON STATE AMENDMENTS • U.P.C. (2009) WITH WASHINGTON STATE AMENDMENTS • I.F.C. (2009) WITH WASHINGTON STATE AMENDMENTS • 2009 WASHINGTON NON RESIDENTIAL ENERGY CODE OCCUPANCY CLASS: GROUP ' M ' TYPE: CONSTRUCTION TYPE II B , UNPROTECTED NONCOMBUSTIBLE TOTAL LEASED AREA: 600 S.F. MAXIMUM ALLOWABLE AREA: — 600 S.F. OCCUPANT LOAD: 5 WORKERS AT ALL TIME WIDTH: INCHES REQUIRED EXIT 36" PROVIDED EXIT WIDTH: 36" INCHES , ii ir ' r ,1 .. C GENERAL NOTES so so , T I I ' - ' l . S ? 1 r CIE L ce, ' 1 ' i ' 1. THESE DOCUMENTS REPRESENT THE SCOPE OF WORK TO BE TO PERFORMED BY THE GENERAL CONTRACTOR ( UNLESS OTHERWISE NOTED.) 2. CHECK DIMENSIONS AND CONDITIONS IN THE FIELD ALL DIMENSIONS AND CONDITIONS OF THIS JOB SHALL BE FIELD CHECKED BY GENERAL CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE START OF CONSTRUCTION. COSTS DUE TO A FAILURE OF REPORTING THESE DISCREPANCIES WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3. ERRORS AND OMISSIONS ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 4. COMPLY WITH DESIGN CRITERIA GENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL EXHIBITS. ( IF APPLICABLE. ) 5. NOTES ALL NOTES ON ANY PORTION OF THESE DOCUMENTS APPLY TO ENTIRE DOCUMENT WHETHER OR NOT THEY ARE REPEATED IN OTHER AREAS. 6. WORK, MATERIALS AND CONSTRUCTION METHODS ALL WORK, MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM WITH ALL GOVERNING AUTHORITIES HAVING JURISDICTION. 7. APPROVAL BY GOVERNING AUTHORITIES APPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE CODES AND STANDARDS. 8. INSTALLATION BY GENERAL CONTRACTOR ALL MATERIALS AND EQUIPMENT ITEMS SUPPLIED BY THE OWNER /TENANT ARE TO BE INSTALLED BY GENERAL CONTRACTOR UNLESS INDICATED OTHERWISE. 9. MATERIALS ALL MATERIALS SHALL BE NEW AND FIRST CLASS. ALL WORK AND EQUIPMENT ITEMS SHALL BE WARRANTIED BY THE CONTRACTOR FORA MINIMUM OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. EXCEPT FOR MANUFACTURE'S WARRANTY WHICH MAY BE LONGER. 10. COMBUSTIBLE MATERIALS NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING. 11. FIRE EXTINGUISHERS CAPACITY AND RATING AS REQUIRED BY N.F.P.A. PAMPHLET #10 AND LOCAL AUTHORITIES. LOCATE PER LOCAL AUTHORITIES AND N.F.P.A. 10. 12. FIRE WALLS ALL FIRE -WALL PENETRATIONS TO BE INSTALLED PER U.L. NUMBERS: L WL 1001 WL 2002 WL 1002 WL 2003 WL 1003 WL 2004 WL 5001 WL 2005 WL 5002 13. MISC. PRIOR TO INSTALLING SHELVING IN REFRIGERATOR, T.G.C. TO WASH DOWN (SPONGE) INTERIOR THREE (3) TIMES WITH A SOLUTION OF 50% VINEGAR AND 50 %WATER. SET REFRIGERATOR TO OPERATE AT 34 - 38 F RANGE. SPECIAL NOTE: _ ' l ‘ 88 mac S Y FUTURE RETAIL PARTITIO: Il — = EXISTING LANDLORD DEMISING PARTITION NORDSTROM = 3 -5/8" OR 6" ( SEE PLAN ) METAL STUDS @ 16" O.C. _ _ _ _ _ = EXISTING INTERIOR WALLS TO BE REMOVED JCPenney CHICKEN NOW r� i i 1 S PACE FC 1 c 600 SQ. FT. —J : 1 li lA • PROJECT I I — . LEVEL 2 O F 3 EMPLOYEE RESTROO M S � `I 1 o , : ��I on Jam' � �' � • 6, ��i - -LORD• i ',i� J uu OW�IR =a WESTFIELD CORPORATION Tenant Coordination - Southcenter 14th Floor 11601 Wilshire Blvd. os Angeles, CA 90025 Atten:.)osh Kimmel (310) 893 -4761 Ph: (310) 478 4456 Fx: (310) 575 5991 MAGIC WO}� 342.1 N. LAKE VIEW DRIVE, SUITE 168 TAMPA FL 33618 ATTN: DAVID WU TEL.: ;(813) 265 -3955 FAX '(813) 265 -3428 I+ , ` �a![I I I LAN DLORD PROVIDED !�r► �► �` .I .� �� �.. I �` I* ,, _I ���1' CONTRACTOR AND ALL SUB - CONTRACTORS SHALL VISIT JOB SITE PRIOR TO THE BID. TO REVIEW ACTUAL FIELD CONDITIONS THAT MAY AFFECT THE BID. CONTACT ARCHITECT WITH ANY FIELD CONDITION AFFECTING DRAWINGS BEFORE BID TO OWNER. IF NOT COMMUNICATED WITH THE ARCHITECT, THEN CONTRACTOR & SUB-CONTRACTOR WILL BECOME RESPONSIBLE FOR ALL COSTS INVOLVED. ' I) I = _ - - — _ _ Ti" PUBL RESTROOMS ,. �I r 1 EXISTING ®EM®ON NOTES EXISTING CONOITION / DEMOLIIION CITY OF TUKWILA BUILDING DIVISION 6300 SOUTHCENTER BLVD #10.0 TUKWILA, WA 98188 ATTN: PLAN REVIEW TEL.: (206) 431 3670 DEPARTMENT OF HEALTH- SEATTLE & KING COUNTY 999 3RD AVE. SUITE 1200 SEATTLE, WA 98104 ATTN: PLAN REVIEW TEL.: (206) 2964600 1 GENERAL CONTRACTOR SHALL REMOVE EXISTING WALL FINISHES AT THIS AREA ONLY AS SHOWN. EXERCISE GREAT CARE IN NOT DAMAGING THE FIRE RATED DRYWALL AT THE DEMISING WALLS. IF DAMAGED, G.C. SHALL REPAIR AS NECESSARY AND PREPARE THE WALL TO RECEIVE NEW FINISHES PER FINISH SCHEDULE AND ELEVATIONS, THE REST OF STOREFRONT FINISHES SHALL REMAIN AS IS, SEE ELEVATIONS FOR THE XTENT OF NEW REMODEL. 2 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING WALL FINISHES IN KITCHEN AREA, RESTORE TO LIKE -NEW CONDITION, AND REPLACE AS REQUIRED. GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED. DISCONNECT AND REMOVE ALL EXISTING ELECTRIC, CAP 3 OFF PLUMBING (IF ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL, CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED. -'--� t �— 1 pRoJEcr 4• COORDINATOR, AR HITECT � _ r..... f__ 14 MOSAD ELEWA 6601 MEMORIAL HIGHWAY STE. 204 TAMPA, FL 33615 TEL.: (8:13) 245 -6554 FAX.: (801) 218 -6554 E -MAIL: INFO @MCDART.NET DAVID HIATT, ARCHITECT 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 PHONE: (813) 289 -3336 ( ) FAX: (813) 289 -3332 4 PLAN .EXISTING GYP. BD. CEILING AT SALES AREA TO REMAIN. GENERAL CONTRACTOR SHALL RESTORE TO LIKE NEW. CONDITION, PAINT PER CEILING LAN AND ELEVATIONS ON SHEETS A -1 &A -3. �= _ — �� �� � 5 EXISTING HVAC SYSTEM AND EXISTING DIFFUSERS TO REMAIN. GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING SYSTEM, SEE NOTE ON SHEET A -1. 6 EXISTING LIGHT FIXTURES IN KITCHEN AND SALES AREA TO REMAIN. GENERAL CONTRACTOR TO VERIFY THE CONDITION OF ALL LIGHTING, RESTORE TO LIKE -NEW CONDITION, AND RELAMP AS REQUIRED. 17 18 :. _ 1, 1 r I ii L �� O 3 ABOVE 7 7 EXISTING LANDLORD BULKHEAD AND CEILING TO REMAIN. 11 III' l I I I I I II 11 e 15 8 CONTRACTOR SHALL COORDINATE WITH OWNER AND RELOACTE EXISTING EXHAUST HOOD TO NEW LOCATION SHOWN ON EQUIPMENT PLAN, REROUTE EXISTING EXHAUST AND MAKE UP AIR DUCT TO NEW HOOD LOCATION ACCORDINGLY / 15 li I 4 1 5 6 1 I 1 ��, ff r�+ � ABOVE 1 LANDLORD NOTES 1!�1 5 9 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING FLOORING, PRESSURE WASH, AND RESTORE TO LIKE NEW CONDITION. I 1 1 J1 10 EXISTING MALL FLOORING TO REMAIN. GENERAL CONTRACTOR TO RESTORE TO LIKE NEW CONDITION AND PATCH AND REPAIR AS NECESSARY ALONG LEASE LINE. 11 CONTRACTOR SHALL COORDINATE WITH OWNER AND REMOVE PORTION OF EXISTING SALES COUNTER MATERIAL AND EQUIPMENT TO ALLOW FOR NEW COUNTER CONFIGURATION SHOWN OF FLOOR PLAN AND EQUIPMENT PLAN. ABOVE I 1 I�IV�I� FILE COPY Permit No.. D12---no �� 15 1 ,. s ", 15 =w Ilan review 13 Approval of construction doc of the violation o any adopted �«�� of approved Copy �_ to erg and omissions. um does not authorize or ordinance. Receipt p acknowledged: — ABOVE � /i/ 8 12 EXISTING HAND SINK TO REMAIN. TO BE RELOCATED, SEE EQUIPMENT PLAN FOR NEW LOCATION. 13 ,ell i� ■ LIKE NEW CONDITION, REPLACING 13 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF EXISTING SINKS THROUGHOUT THE SPACE AND RESTORE TO IKE N O AS NECESSARY. 14 CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING WATER HEATER AND MOP SINK. INSTALL NEW AS REQUIRED. 15 EXISTING EQUIPMENT/FIXTURES TO REMAIN. VERIFY CONDITION. 16 CONTRACTOR SHALL COORDINATE WITH OWNER AND REMOVE /REPLACE /RELOCATE COOKING EQUIPMENT. CONTRACTOR SHALL INSTALL RELOCATE THE GAS L INES /ELECTRICAL OUTLETS ACCORDINGLY, SEE NEW EQUIPMENT PLAN CONFIGURATION. 17 EXISTING ELECTRICAL POWER SUPPLY, PANELS AND TRANSFORMER TO REMAIN. SEE NOTE ON SHEET A -1. 10 / 16 2 l � I !I0 15 15 J III �`V �J1 / 'Pa 13 Sri Dad:, r� =i_ — 15 — J l� �a City Of BUILDING DIVISION RECEIVED JUN 0 72012 TUKWI PUBLIC WORKS RECEIVED r JUN 05 2012 PERMIT CENTER 9 , _ �— _ 15 ._ . 3 , — 9 18 EXISTING SERVICE DOOR TO REMAIN. ADD NEW HARDWARE AS REQUIRED. SEPARATE PERMIT REQUIRED FOR: �;i Mechanical IA Electrical Plumbin g L`i[ Gas Piping City of Tukwila Uii -L I ,YG DIVISION a : 2 3 +0 7 ilia � r_ III I .. - , I - 1 ---�. REVISIONS is No changes shall t made to the scope of work without prior approval of Tukwila Building Division. NOTE Revisions will require a new plan submitt'! and may include additional fees. 11 IV ire 12 _ — � 1 plan review ..._!.M...___ DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: SOUTHCENTER REVISIONS 633 SOUTHCENTER SPACE FC11 WA 98188 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 ` 6444 REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON COVER SHEET SHEET NUMBER OF.1 CONSTRUCTION NOTES 000R SCHEDULE 010( GENERAL CONTRACTOR SHALL VERIFY EXISTINANCE AND CONDITION OF 1 -LAYER OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT ALL DEMISING WALLS. ALL DEMISING PARTITIONS ARE TO HAVE 5/8" TYPE 'X' GYPSUM WALLBOARD FROM FINISH FLOOR TO UNDERSIDE OF DECK, CONTINUOUS. PER #U425. Clop GENERAL CONTRACTOR SHALL PROVIDE F.R.T. BLOCKING AS REQUIRED FOR INSTALLATION OF NEW HAND SINK. ALL BLOCKING TO BE 3/4" F.R.T. PLYWOOD (MARINE GRADE IN WET AREAS). SCREW FASTEN BETWEEN METAL STUDS AT NEW PARTITIONS AND FURRED WALLS. COVER W/ 5/8" GYP BD. AND FINISH WITH PER ELEVATIONS. SEE DETAILS THIS SHEET. 102) NOT USED (104) 105 GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW INTERIOR PARTITION WITH 3 -5/8" METAL STUD AT 16" O.C. PART. WITH 5/8" WATER RESISTANT WALLBOARD ON BOTH SIDES OF WALL BETWEEN SALES /KITCHEN; TAPE AND SPACKLE; REMAINING INTERIOR WALLS TO HAVE 5/8" WATER RISISTANT GYP. BD. BOTH SIDES, TAPE & SPACKLE. NOT USED WALL TILE, SOFFIT TILE AND BASES IN ROOMS WITH GYPSUM WALLBOARD WALLS SHALL BE THIN SET WITH ADHESIVE IN ACCORDANCE WITH THE TILE COUNCIL OF AMERICA, INC. ANSI A- 108.5. NOTE: ALL WALL AND SOFFIT TILE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. (1.06) GENERAL CONTRACTOR SHALL PROVIDE & INSTALL TILE T -4 ACCORDING TO MANUFACTURERS INSTRUCTIONS FOR APPLICATION OVER GYPSUM DRYWALL. C107) (108) GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL PANELS OVER GYPSUM WALL BOARD FROM TOP OF QUARRY TILE BASE TO BOTTOM OF HOOD. ALONG THE LENGTH OF THE HOOD AT BACK AND SIDES. GENERAL CONTRACTOR SHALL INSTALL 1 -1/2" X 1 -1/2" 16ga.S /S CORNER GUARDS OR END CAPS FLOOR TO CEILING AT ALL OUTSIDE CORNERS WITHIN THE PREP. ROOM, SCREW FASTEN AND SEAL WITH CLEAR SILICONE. TYP. ALL OUTSIDE CORNERS. SEE DETAIL 3/A -2. NOT USED EXISTING QUARRY TILE FLOORING TO REMAIN, PRESSURE WASH AND RESTORE TO LIKE NEW CONDITION. CUT OUT FOR EQUIPMENT. VERIFY SIZE PRIOR TO CUTTING COUNTER TOP. SEE EQUIPMENT PLAN AND SCHEDULE. NOT USED EXISTING 2'X4' LAY -IN CEILING SYSTEM AS INDICATED ON REFLECTED CEILING PLAN. VERIFY CONDITION REPLACE ANY DAMAGED TILE WITH NEW. 014) EXISTING GYP. BD. CLG. TO REMAIN, GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW 5/8" TYP. "X" GYP. BD. CEILING AND PAINT P -1 AT RELOCATED EXHAUST HOOD. GENERAL CONTRACTOR SHALL RECONFIGURE EXISTING SALES COUNTER TO ACCOMEDIATE NEW STEAM TABLE AND COLD PANS, RECONFIGURE CASEWORK ACCORDINGLY, COORDINATED WITH EQUIP FOR SIZE OF EQUIPMENT SUPPLIER BEFORE MAKING ANY COUNTER CUTOUT. SUPPLIER, SEE SECTIONS SHEET #A -4 . INSTALL ALL FINISHES AS SPECIFIED. ALL JOINTS IN AND AROUND CABINETS, SINKS, VENTILATOR, ICE BIN, ETC., TO BE SEALED WITH CLEAR SILICONE SEALANT. PROVIDE BLACK PLASTIC WIRE WAY GROMMETS AT ALL DRILLED OPENINGS. GENERAL CONTRACTOR SHALL REFURBISH ANY L.L. AREAS DAMAGED AT THE STOREFRONT TO A LIKE NEW CONDITION. ( NEUTRAL PIERS, NEUTRAL BANDS, ETC. ) EXISTING SPRINKLER AND /OR FIRE ALARM TO REMAIN. . SPRINKLER CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS FOR CONSTRUCTION AND PERMITTING UNDER SEPARATE COVER TO THE ARCHITECT, LANDLORD AND GOVERNING AUTHORITIES FOR APPROVAL PRIOR TO ANY MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM. COORDINATE MODIFICATION SCHEDULE W/ L.L. FIELD REP. SYSTEM IS TO BE FULLY CHARGED AND OPERATIONAL WHEN G.C. IS OFF SITE. FINAL SPRINKLER LAYOUT TO BE DETERMINED BY SUBCONTRACTORS SHOP DRW'GS. (119) EXISTING MECHANICAL DIFFUSERS TO REMAIN. MARK DESCRIPTION TYPE FINISH JAM B JAM B FINISH JAM B DETAIL HARDWARE EXISTING 3' -0 "x 7' -0" H.M. DOOR U.L. LABEL "B" B P -1 STEEL U.L. LABEL "B" P -1 3 STANLEY HINGES: FBB179, 4- 1 /2 "x4- 1 /2 ",NRP, 26D 1 SCHLAGE LOCK, D8OPD RHODES, 626 (LEVER HANDLE) 1 NORTON CLOSER, P8301BF SNB ALUM. 1 KICK PLATE, 12x2 "LDW, 32D 1 IVES VIEWER, 698B26D 1 STOP AS REQUIRED 3 SILENCERS 1 THRESHOLD 'PEMKO' #2005 AT ��- P -1 S.S. KICK TYPE B PLATES HOLLOW METAL HEAD/.IAMB EXIST. 5/8" TYP. "X" GYP. BD. T -4 OVER 5/8" GYP. BD. EXISTING DEMISING WALL STUDS EXISTING HOLLOW METAL FRAME, W/ THREE JAMB ANCHORS PER JAMB. B -LABLE EXISTING 1 3/4" H.M. B -LABLE DOOR. PAINT P -1 (BOTH SIDES AND EDGES) 3" =1'-O" GANG FIXTURE SCHENIA 0000 TYPE DESCRIPTION MANUFAC. CATALOG LAMP MTG. VOLT REMARKS LAMPS/ FIXT. BALLASTS BALLAST/ FIXT. TOTAL WATT A 0 EXISTING 2 -LAMPS 2x4 RECESS TROFFER MERCURY 35E2320CT9A125ELB (2) F032T8/841 RECESSED 120 W /ELECTRONIC RAPID START BALLAST 2 B EXISTING 2 -LAMPS 2x4 RECESS TROFFER MERCURY 35E2320CT9A125ELB (2) F032T8/841 RECESSED 120 W /ELECTRONIC RAPID START BALLAST 2 ELECTRONIC SYLVANIA QTP2X32T8 /UNV PSX -SC 64 ELECTRONIC I 1 164 SYLVANIA QTP2X32T8 /UNV PSX -SC C EXISTING /NEW COUNTER COVE LIGHT BARTCO LIGHTING TEL: 714 - 230 -3200 BFLSLM -14/6 28W T5 46 1/16" LAMP UNDER COUNTER COVE LIGHT 120 MINIATURE LINEARE T5 FLUORESCENT SINGLE WIDTH STAGGERED. 6" LAMP OVERLAP. 1 INTEGRAL BALLAST. 1 28 E '1 EXISTING /NEW RECESSED DOWN LIGHT HALO H274HP -120V F13DTT -Halo Z64 RECESSED 120 1 1 13 F EXISTING DECORATIVE PENDANT LIGHT VAXCEL PD30119SN - LAVA SWIRL MINI PENDANT (1)50W B10 CAND C INCANDESCENT MPT MONOPOINT 120 COORD W /OWNER CALL LIGHTING UNIVERSE (800) 801 -2207 1 N/A N/A 50 EX EXISTING EXIT LIGHT ATLITE PNLRU FURNISHED W /UNIT UNIVERSAL 120 90 MINUTE BATT. BACKUP POWER N/A N/A N/A 20 EM EXISTING RECESSED EMERGENCY LIGHT ENCORE LIGHTING ERG -630 -R ERG SERIES A PAR 36 SEALED BEAM LAMP RECESSED 12 FULL LIGHT OUTPUT FOR OP TO 4 HOURS. BATTERY CAPACITY 30 N/A N/A N/A EXISTING LOW WALL REVIEWED FOR CODE COMPLIANCE APPROVED ADJACENT TENANT FLOOR p SCALE: 1/4" = 1' -0" MALL COMMON AREA DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: SOUTHCENTER REVISIONS 633 SOUTHCENTER SPACE FC 1 1 WA 98188 NOTES: OELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. O2 INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. ALL LAMPS TO BE SYLVANIA UNLESS NOTED OTHERWISE. OPROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA. 5/8" WATER RESISTANCE GYP. BD. INSTALL FINISH PER ELEVATIONS AND NOTES. 3/4" 2 7/8" HORIZONTAL BLOCKING SUPPORT; 2 1/2" 16 GA METAL STUDS BETWEEN WALL STUDS. 3/4" FIRE RATED PLY -WOOD BLOCKING FLUSH TO BACK SIDE OF GYP.BD. 3 5/8" M.S. INNER IMF NIP INNIMINEMINIIIIIMPEWINE UNIIIMMOM SEE EQU PMENT PLAN FOR PLUMBING ACCESS. SCHEDULE SINK WITH LEVER HANDLE FAUCET BLOCK'G. PER DETAI THIS SHEET. EXTEND BEYOND MIN. OF 6" F.F - FIXTURE OR EQUIPMENT. AREA OF BLOCK'G. SHOWN HATCHED. SOON: NON DEMISING WAll N LE . T SINK TM SCALE: AS BLOCKING Do SCALE: AS NOTED A-1 HAND SINK IN AT1oN City of Tukwila - --BUILDING DIVISION 10' -0" A F F C 13-3 BOTT. OF SOFFIT EXISTING SIGN 11' -0" A.F.F. BOTT. OF EXISTING SIGN BAND 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 EXISTING SUSPEND CEILIN (SCP -1) 12' -10" BOTT. OF 0_ NEW GYP. BD. & CLG. AT HATCHED AREA 12' -0" A.F.F. BOTT. OF EXISTING SOFFIT /SH NEW MENU BOARDS 7' -0" A.F.F. EXISTING RECESSED FLUOR. LIGHT FIXT. BOTT. OF EXISTING SOFFIT 12' -10" BOTT. OF R�EGlSTf~D AR2CHITECT RC DAVID W. HIM - STATE OF WASHINGTON EXISTING GYP. BD. & CLG. (, P -2 LEASE LINE 2' -0" EXISTING RECESSED LIGHT FIXT. f� ■ NOTE: ALL LIGHT FIXTURES ABOVE THE SERVICE, PREPARATION, UTENSIL WASHING AND FOOD STORAGE AREAS (INLCUDING THOSE LIGHTS WITHIN STEAM TABLES, REFRIGERATION UNITS HOODS AND COOKING EQUIPMENT) SHALL BE SHIELDED OR EQUIPPED WITH SHATTER -PROOF BULBS. EXISTING RELOCATED EXH. HOOII" REMOVE PORTION CLG. TO ALLOW FOR THE INSTALLATION OF RELOCATED HOOD. RECEIVED JUN 05 2012 IT CENTER Atr c PLAN SCALE: 1/4" = 1' -0" ri FLOOR PLAN, CEILING PLAN & NOTES SHEET NUMBER III OF.5 EQUIPMENT UST * = EXISTING TO REMAIN *R = EXISTING RELOCATED N = NEW BLOCKING I • • t CLASS ABC FIRE EXTINGUISHERS. EXTINGUISHERS 1 1 MARK RESPONSIBILITY® ITEM/ QNTY DIM.S SPECIFICATIONS: REMARKS: FLOOR SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT, ABOVE THE FLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES ABOVE THE FLOOR. EXTINGUISHERS r' „ CLASSIFICATION, RATING, AND DISTRIBUTION „„ REQUIREMENTS OF NFPA 10. [NFPA 1: 13.6.1.2] ` ` -. __• �- „ _� „ _ „. - .. „ . •. � „ 1 �d ® 41 _ +' Vii= O 1 SERVICE COUNTER (CSCI) 1 VARIES SEE PLAN EXISTING, MODIFY PER PLANS AND SECTIONS PROVIDE AND INSTALL MARINE GRADE PLYWOOD AT ALL WET AREAS INCLUDING BEVERAGE AND STEAM TABLE AREAS. "DAL - TILE 6 '1X6" "ARID GRAY" #Q42 SMOOTH ABRASIVE, TILE HAS WET -DRY (QT -1 ) S.C.O. F. OF 0.73 -0.90 INSTALL WITH CADET GRAY COLOR GROUT. SEE CONSTRUCTION NOTES AND SPECIFICATIONS FOR INSTALLATION PROCEDURES. * 2 POINT OF SALE (OSCI) 3 Casio #QT -8000 BASE N 3.0 3 WELL STEAM TABLE W/ OVERSHELF & SNEEZGUARD (OSCI) 1 43 -1/2" W 19 -7/8" D ATLAS METAL WIH -3 208 V, 2.55 KW, 12.3 AMPS CUT -OUT REQUIRED: 22 -1/4" D x 41 -3/4" W L6 -20P NEMA CONFIGURATION " " " (QTB -1) COVED TILE BASE = 6 HIGH, DAL -TILE TO MATCH QT -1 N 3A FRIED FOOD HOLDING STATION (OSCI) 1 24.6" D 13" H MERCO COUNTERTOP MODEL #FFHS -16, 120 VOLTS, 12.3 AMPS, 1450 WATTS 5 -15P NEMA CONFIGURATION WALLS ® EXISTING 12X12 MOSAIC N 4 3 -WELL DROP -IN COLD PAN (OSCI) 1 45.32" W 26" D DELFIELD MODEL #8145 -EF 115 V, 60 HZ, 1 PH, 7.0 AMPS, 1/4 HP CUT -OUT REQUIRED: 25.00" D x 44.25" W ® 4- 1/4 "X4 -1/4" DALTILE GLASS REFLECION "WHITE ICE #CR13" N 5 SNEEZE GUARD (OSCI) VARIES PLAN CUSTOM FABRICATED }" TEMPERED GLASS WITH FLOUR. LIGHT FIXTURE, SEE SECTIONS FIRE EXTINGUSHERS -CLASS K 40 ® 6 "X12" ASI PORCELAIN COLLECTION FLCCD344 PHOENIX STYLE CLASS K FIRE EXTINGUISHERS - • * 6 BAOG -IN 1 COKE Co. SHALL BE PROVIDED FOR HAZARDS 44 WHERE THERE IS A POTENTIAL FOR Em 29 It 1 GLASSDSNEEZE Q * 7 SODA DISPENSER/ ICE BIN 2 "SITCO" #WRD -6 ; REQ. 11OV /20 AMP GRND. OUTLET • 1/2" CW REDUCED TO 3/8" W /GATE VALVE. 1 -1/2" DRAIN FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE COUNTER TOP. FITS CUT OUT MEASURING 23 -1/4 "x23 -1/4" CONTACT SANDY MANUEL 813 973 -3465 TO COORD. DELIV. ( ) FIRES INVOLVING COMBUSTIBLE I B A 4X4 WHITE CERAMIC TILE. "DAL- TILE" #D -100 WITH MATCHING COLORED SAND i COOKING MEDIA. [NFPA 10:4.3.2] /tJ/ . Ern I GROUT. * R 8 COLD -CUP DISPENSER (3) 4.375 "D 5.875 "D "TOMLINSON" MODEL #ELC -1002 "TOMLINSON" MODEL #ELC -1020 FIELD VERIFY EQUIPMENT BEFORE MAKING ANY CUTS IN THE COUNTERTOP. � 42 kr,■1104- "i.� ?j ® 12X35, PORCELONSA WALL TILE, BRUNI GRIS FNO 9 REAR/SIDE COUNTER 1 VARIES SEE PLAN CUSTOM FABRICATED STAINLESS STEEL CALL JULIO HERNANDEZ, 305 - 715 -7153 ® 0 { t 1 * C�J; * 10 MENU BOARD 1 VARIES SEE PLAN CUSTOM FABRICATED SEE SECTIONS LCD PANELS COUNTERS I 1 O 0 (GR -1) 3/4" THICK GRANITE "BLACK GALAXY" INSTALLED PER MANUFACTURER'S RECOMENDATIONS CEILINGS r----- II �' * li CONDIMENT HOLDER 8 COORD. WITH OWNER �� ® ■ * R 12 DRINK DISPENSER 1 CRATHCO D35 115V/60 HZ, 8.5 AMPS I r I + I '_� UU!I 42 �\ 4III!I ':I 1 1 "USG", (SCP_1) SUSPENDED CEILING PANELS: 2'x4' VINYL CLAD GYPSUM ROCK, USG , 11 * 16 GAS GRIDDLE /RANGE 1 34" W 39" D 36" H VULACAN #GH60T /45 MUST BE PROVIDED W/ LEGS, STAND AND CASTERS . MUST BE UNDER HOOD VENTING 200 F.F.M. FER SQ. FT. OF EQUIP. SURF. 3/4" GAS INLET I5 LOCATED AT LEFT REAR. GAS PRESSURE MUST BE 6" W.C. FOR NATURAL OR 10" W.C. FOR PROPANE BTU /HOUR TOTAL = 150,000 BTUH PROVIDE DORMONT QUICK DISCONNECT SYSI EM. •uU l 1 IM, !I , � � GRID: CHICAGO METALIC: SERIES 830 ALUMINUM W/ WHITE FINISH #41 (GB-1) GYPSUM BOARD, CEILING- 5/8" TYPE "X" PAINTED PER REFLECTED CEILING PLAN 42 I I *&LIO 4 * R 18 ELECTRICAL GRILL 1 12" W 35. 15 H TAYLOR COMPANY QS12 208 VOLT/ 60 HZ / 3R1 PROVIDED W/ L15 30P 9.6 KW, 27 AMP ` + • C . O O * R 17 HEAT LAMP STRIPE 1 CUSTOM HATCO OVERHEAD WARMER HEAT LAMP GLO -RAY® INFRARED FOODWARMER, HIGH WATTAGE, TUBULAR METAL HEATER ROD, SINGLE HEATER ROD HOUSING, ALUMINUM CONSTRUCTION, 1100 WATTS, " %` O� 44 O I I �� �� PAINT METAL DOOR & FRAME ETC.: "SHERWIN WILLIAMS" CELU -TONE SATIN LUSTER ENAMEL; WHITE, USDA APPROVED. II Raj * R 24 HIGH VOLUME GAS FRYER 1 62" W 35 D 33" H ULTRAFRYER SYSTEM MODEL# B- P30 -14 -4 360 000 BTU /HR 120V/60 HZ/ 1Qf 8.5 AMP UNIT TO BE VENTED UNDER CANOPY W /MECH. EXHAUST SYS. 3/4 I.P.S. MANIFOLD AND GAS CONNECTION. PROVIDE DORMONT" QUICK DICONNECT SYSTEM. GAS PRESSURE TO 11 11 BE 6 W.C. FOR NATURAL OR 11 W.C. FOR PROPANE. BENJAMIN MOORE RED (2000-10) 44' O �,� B A i I, a C7 II!L BENJAMIN MOORE SOFT BEIGE {2156 -60) # 1E1 ( P -4 BENJAMIN MOORE RACING ORANGE (2169-10) •'° _ .......... Cy ► N 25 SANDWICH PRESS (OSCI) 2 16" W 23 -1/8" D 14 -3/8" H STAR MANUFACTURING INTERNATIONAL INC. MODEL #GR14SPTA 2 -SIDED GRILL, 120 V, 2300 WATTS, 19.2 AMPS 5 -20 NEMA CONFIGURATION 12' B A , , 12 ® STAINLESS STEEL. ... - • „._.• _ „ "•`• „• J8 R 26 EXH. HOOD 1 24'H W /LIGHT FIXTURES SEE HOOD DRAWING LENGTH & WIDTH VARY, SEE PLAN AND HOOD SHOP DWGS. EXHAUST /SUPPLY DUCTS TO BE CUSTOM SIZED FOR CONTROL OF SMOKE FROM WOK. pp�aa�REVIEWED y��++ �Rgpp CODE 6+V1116�L9�8"A 1 APPROV D JUG 2 2 '�01� City of Tukwila ._.,. „ -..._- ._..•..... „,_„ -- „ i t ANSUL SYSTEM TANKS AND CONTROL PANEL 1 "ANSUL" PRE -ENG. LIQUID CHEMICAL FIRE SUPPRESSION SYS. W /FIXED NOZZELS. SYS. TO BE UL CLASSIFIED AND INSTALLED PER NFPA #96 REQ. SYSTEM SHALL BE CAPABLE OF AUTOMATIC AND MECH. OPERATION W /AUTO SOLINOID GAS VALVE SHUT DOWN. ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. MIN HGT. TO BUTT. OF UNIT TO BE 6' -6" AFF. NOTE: NOZZELS AND PIPING IN PUBLIC VIEW SHALL BE CHROME FINISHED. ELEC: FOR EMERGENCY SHUT OFF, CONNECT CONTROL PANEL TO SOLINOID FOR SHUT DOWN OF GAS SUPPLY UPON ACTIVATION. PLUMB:CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. NOTE: „ „� 1. ALL FINISHES TO BE MIN. CLASS "C. 2. ALL MATERIALS USED FOR INTERIOR FINISHES AND TRIM SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84. BUILDING D9 �'��� SCALE: 1/4" = 1' -0" EXISTING * 23 HOLDING CABINET 1 26" W. 32" D 36" H ALTO SHAAM 125 v 1 ph. 16 amp. FILL VOIDS WITH U.L. #HW -S -0009 (1 -HR) CEILING SUPPORT WIRE * 29 ICE MAKER ICE BIN 1 CUBER 22" W. 30 -1/4" H BIN 30" W. 34" D 44" H. "MANITOWOC" #SN950 CUBER AIR COOLED: 208-230/60/1 15.0 AMPS 3 WIRE W /NEUTRAL FOR 115V 8570 ALLOW 6" AIR CLEARANCE @ BACK OF UNIT. ELEC: 208- 230V!60!1 - 7 AMPS SIMPLEX @ BO' AFF (3 WIRE WITH NEUTRAL FOR 115V) PROVIDE 6' CORD AND PLUG TO UNIT. PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & CURER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT WASTE FROM CONDENSER TO FLOOR DRAIN. MAINFOLD AS REQUIRED. INSTALL4JION NOTES: :.-.-.-•- aa•- aa•-.-.- .- :.-.-a•-a..��..•- ....:....... ���������������������������������������� :44:44 14. .444x444444.4 444:4444444% %%%4.%%i: 7111111131 1• BRING INCONSISTENCIES BETWEEN FINISH MATERIAL NOTES, FINISHES PLAN, INTERIOR ELEVATIONS & DETAILS TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO ORDERING MATERIALS OR BEGINNING INSTALLATION. 2• SUBCONTRACTORS MUST EXAMINE EACH INSTALLATION AREA FOR CONDITIONS INTERFERING WITH PROPER, TIMELY, OR ACCEPTABLE COMPLETION OF THE WORK & SHALL NOTIFY THE GENERAL CONTRACTOR OF UNACCEPTABLE CONDITIONS REQUIRING ATTENTION BEFORE FINISH MATERIAL INSTALLATION. 3• DO NOT BEGIN FINISH MATERIAL INSTALLATION BEFORE UNACCEPTABLE CONDITIONS HAVE BEEN CORRECTED IN A MANNER ACCEPTABLE TO THE GEN. CONTRACTOR & ARCHITECT FOR THAT PORTION OF THE WORK. 4. PERFORMANCE OF THIS WORK BY THE INSTALLER INDICATES ACCEPTANCE OF ALL SUBSTRATE CONDITIONS & ASSUMPTION OF RESPONSIBILITY FOR COMPLIANCE WITH MATERIAL INSTALLATION QUALITY STANDARDS. - 1I S/S CHANNEL WELDED EXISTING EXISTING FLOOR &CEILING RUNNER: 20 MSG (MIN.) GALV. STEEL 1 IN. HIGH, RETURN LEGS 3-5/8 IN. WIDE (MIN.) ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. 100 GYPSUM DECK EXISTING , , 1 SUSP. CLG. STAINLESS 3" TO HOOD BY MANUFACTURER SEAL TO DECK C10a) JOINT TAPE & COMPOUND * 32 3 -COMP. SINK 1 96 "W 30 -1 /2 "D 40 -1/2 "H "EAGLE" MODEL #412- 18 -3 -18 R&L BOWL SIZE 24x18; PROVIDE W / "FISHER" #3254 BACKSPLASH MOUNTED FAUCET PROVIDED W /1 -1/2" IPS BASKET "TYPE WASTE. PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS, PROVIDE W/T&S FAUCET SPRAYER #T- 40 /B129BV W /ADD ON FAUCET #8156 ADF. STEEL TRIM * 33 1 -COMP. SINK 0 38.5 "W 27 -1 /2 "D 40 "H "EAGLE" MODEL #414- 16 -1 -18 R OR L BOWL SIZE 20X16 PROVIDED W /1 -1/2" IPS BASKET TYPE WASTE. PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS. WALLBOARD: 5/8 IN. THICK, TYPE X, 4 FT. WIDE, ATTACHED TO STEEL STUDS AND FLOOR * 34 MOP SINK 1 24 D FIAT 2424 SEE PLUMBING R 39 SANDWICH TOP REFRIG. 2 32.31" W 11 31.5" D 46" H DELFIELD 4432 mega 7.2 ref. 115/60/1 7.2 AMPS 1/5 HP ,,�„ni.� AND CEILING TRACK WITH 1 IN. LONG, TYPE SSELF- TAPPING STEEL SCREWS SPACED 8 IN. O.C. ALONG EDGES OF BOARD AND 12 IN. O.C. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. U.S, GYPSUM CO.-TYPE 'C' OR EQUAL. HOOD * 39A WORK TOP REFREGIRATOR 1 48" " D. Continental Refrigerator Model: SW48 WORKTOP COOLER 115/60/1 7.2 AMPS 1/5 HP R 39B WORK TOP FREEZER 1 48 -3/8" W 30 "D 33 "H TRUE TWT -48F 115/60/1 5 AMPS 1/5 HP VINYL, DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS; PAPER T� AT ®®D 2 EQUIPMENT �• * 40 WATER HEATER 1 SEE PLUMBING 1. ALL EQUIPMENT AND SIGNAGE SHALL BE PURCHASED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. 2. FOOD SERVICE AND BEVERAGE DISPENSING EQUIPMENT SHALL COMPLY W/ NSF REQUIREMENTS AND REQUIREMENTS OF LOCAL HEALTH OFFICIALS HAVING JURISDICTION. 3. INSTALLATION AND CONNECTION OF ALL FOOD SERVICE EQUIPMENT IS TO BE PERFORMED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE INDICATED. 4. SHELVING UNITS SHALL BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR. 5. FOOD SERVICE EQUIPMENT REQUIRING AN ELECTRICAL CONNECTION IS TO BE FURNISHED W/ CORD AND PLUG UNLESS OTHERWISE INDICATED. 6. VERIFY THE ELECTRICAL AND MECHANICAL RE UIREMENTS OF FOOD Q SERVICE EQUIPMENT PRIOR TO INSTALLATION. 7. SINKS SHALL BE PROVIDED W/ DRAIN TAILPIECES AND FITTINGS. THE GENERAL CONTRACTOR SHALL PROVIDE SHUT -OFF VALVES, SUPPLIES AND TRAPS NECESSARY TO CONNECT SUCH SINKS. 8. PROVIDE A SHUT -OFF VALVE AT HOT AND /OR COLD WATER SERVICE TO EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTION(S). 9. PROVIDE A BACKFLOW PREVENTER AT EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTIONS. ( NOT INCLUDING SINKS ) NOTE: TAPE, 2 IN. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVERALL JOINTS. AS AN ALTERNATE, NOMINAL 3/32 IN. SCALE: 3" = 1' -0" A -2 * 42 WALL SHELF 3 14 "D 74 "H "METRO" WALL UNIT SEE PLAN FOR WIDTH THICK GYPSUM VENEER I 1 *SHELF 44 UNIT (OSCI) 3 SEE PLAN "EAGLE" 4 -TIER COATED WIRE SHELVING CATALOG #1860Z W /P74 -C POSTS GEN. CONTR. SET SHELF HGTS. AS FOLLOWS: BOTTOM SHELF:6" A.F.F. / SECOND SHELF:24" A.F.F. THIRD SHELF:48" A.F.F. / FOURTH SHELF:72" A.F.F. EXISTING STEEL STUDS: PLASTER MAY BE APPLIED 3 5/8" IN. WIDE (MIN.) TO THE ENTIRE SURFACE 1 -1/4 IN. LEGS, 3/8 IN. OF CLASSIFIED VENEER RETURN, FORMED OF 25 BASEBOARD, JOINTS MSG (MIN.) GALV STEEL MAX REINFORCED. STUD SPACING 24 IN. O.C. * R 46 HAND SINK DROP IN (osCI) 1 14 -1/2 "W 18 -1/2 "D "EAGLE" MODEL #HSA -10 -F PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS ,- TILE OR * 46A HAND SINK WALL MOUNTED O & NEW EXISTING 1 10 "w 14 "D io "H "ADVANCE" MODEL #D1 -1 -10 PROVIDE 1/2" IPS HOT & COLD WATER CONNECTIONS • TILE OR FRP FINISH . * 47A 2 DOOR FREEZER (OSCI) 1 52" 35" D. „ 83 H. TRAULSEN #G22010 115/60/1 NEMA L14 -20P PLUG 14,9 AMP 3/4 HP r FRP FINISH r-- --. i 1 I -� EXISTING EXIST.FLOOR & CEILING RUNNER: 20 MSG (MIN.) GALV. * R 47B 2 DOOR COOLER (OSCI) 1 58" L 35" D. 83" H. TRAULSEN #RHT232WUT -FHG 115/60/1 NEMA L14 -20P PLUG 10.4 AMP 1/2 HP STEEL 1 IN. HIGH , RETURN LEGS 3 -5/$ IN. WIDE (MIN.) ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. �- 1 J I'll . 1 : __ - °'- '-- -_ -_J N 4s SANDWICH TOP REFRIGERATOR (OSCI) 1 . 60 -3/8" W 30 -1/8" D 36 -3/4" H TRUE MODEL #TSSU- 60 -12, 12 PANS, 4 SHELVES, 15.5 CUBIC FEET, 1/3 HP, 115 VOLTS, 60 HZ, 1 PHASE, 7.8 AMPS, WITH OVERHEAD SHELVING 5 -15P NEMA CONFIGURATION _ 11 2 _ 16 GA S/S ANGLE CORNER GUARD, SET IN PLACE W/ SLAB i QTB -1 BASE SALES AND KITCHEN AREA, STR'L ADHESIVE & 16 GA.S /S END WALL CAP SILICONE ALL EDGES GUARD, SET IN PLACE W/ 5TR L ADHESIVE & PLAN VIEW SILICONE ALL EDGES * 51 ELECT. PANELS (cscl) 1 SEE ELECTRICAL DWG. • �� ALL FIRE -WALL PENETRATIONS TO BE INSTALLED PER U.L. NUMBERS: WL 1001 WL 2002 WL 1002 WL 2003 WL 1003 WL 2004 WL 5001 WL 2005 WL 5002 3 ®® SCALE: 1 1/2" = 1' -0" A -2 AREA FLOOR WALLS CEILING BASE THE ABBREVIATIONS NOTED ON THE EQ. SCHEDULE: "O.S.C.I." STAND FOR: 0= OWNER C= CONTRACTOR S= SUPPLIED I= INSTALLED KITCHEN TILE QT -1 WHITE CER. TILE T -4 WASHABLE VINYL FACED LAY -IN TILEG QTB -1 U.L. DESIGN NO. U425 NONBEARING WALL RATING - 1 HR. TO. ALL SECTION T �� 1 �� 1 ct 0 RECEIVED JUN 05 2012 PERMIT CENTER ACCESSORIES SCHEDULE. SURFACE BOBRICK #B-87 TED SOAP DISPENSER SALES QUARRY TILE QT -1 CER. TILE SEE ELEV. PAINTED RED, QTB-1 1 - A SCALE: 3/4" = 1' -0" A -2 GB -1 SURFACE MOUNTED PAPER TOWEL DISPENSER- BOBRICK #B2621 B QUARRY TILE QT -1 STAINLES STEEL PANELS SEE ELEV. PAINTED SOFT BEIGE, - QTB -1 GB -1 DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: U LL REVISIONS SEATTLE WA 98188 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 .:444 P;-----GISTERED ARCHITECT DAVID W. HIAT1' STATE OF WASHINGTON EQUIPMENT PLAN, SCHED. DETAILS, FINISH SCHED. SHEET NUMBER OF.5 N EW 1/4" TEMP. GLASS PANELS OVER GRAPHIC MURAL 11 0 EXISTING COUNTERTOP MATERIAL TO REMAIN EXISTING "CHICKEN NOW" SIGN. PER CONTRACTOR. SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO L.L. FOR APPROVAL PENDANT LIGHT - -� RELOCATE TO CENTER ON NEW SNEEZE GUARD J chicken Howl REMOVE TEMP GLASS SNEEZE GUARD + , V // 7-711 k \ \� 0 N 0 O EXISTING MOSAIC TILE TO REMAIN EXISTING 6" BASE S -S FLUSHED WITH TILE SCALE: 3/8" = 1' -0" 14' -7" 12" BASE S -S 9' -5" ATION (DEMO) 1/4" TEMP. GLASS PANELS BACK PAINTED RED TO MATCH EXISTING RED COLOR NEW RECESSED PRE FAB. MENU BOARD BOX FLUSHED W /FACE OF GLASS EXISTING 1/4" BACK PAINTED TEMP. GLASS PANELS P -4 PAINZ. COLOR. ORANGE EXISTING 4X4 GLASS TILE EXISTING 1/4" TEMP. GLASS PANELS BACK PAINTED RED 0 N REMOVE EXISTING 1/4" TEMP. AND ART MURAL. RECONFIGURE THIS AREA FOR NEW STEAM TABLE AND COLD PANS. N 0 EXISTING "CHICKEN NOW" SIGN. PER CONTRACTOR. SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO L.L. FOR APPROVAL PENDANT LIGHT RELOCATE TO CENTER ON NEW SNEEZE GUARG EXISTING COUNTER TOP MATERIAL TO REMAIN NEW 3/8" TEMP GLASS SNEEZE GUARD (GR -1 ,,;.tip tit tY ftY� \fns }? ii hicken newl EXISTING MOSAIC TILE TO REMAIN EXISTING 6" BASE COO FLUSHED WITH TILE 0 O EXISTING —S /S PANELS — EXISTING S/S \�A■ HATCH AREA INDECATES EXISTING TO REMAIN EXISTING SOFFIT UNDER BULKHEAD 12' -6" A.F.F. 3' -5/8" METAL STUDS FRAMING & BRACING L.L. BULKHEAD NEW TILE EXISTING MOSAIC TILE TO REMAIN (NI 0 —\ REVIEWED �• E E V1/ Eu F©R CODE COMPLIANCE APPROVED JUN 2 2 2012 City of Tukwila BUILDING DIVISION EXISTING 'CHICKEN NOW'. SIGN TO REMAIN EXIST. LANDLORD NEUTRAL PIER n u u chicken now \OPEN h 1 2' -10" OP OF COUNTER EXIST. LANDLORD NEUTRAL PIER LEASE LINE SCALE: 3/8" = 1' -0" QTB -1 o' —o" /II\ \ / \I \ \ / \ / NEW r 12' -10" A.F.F YP. BD. CLG. G (P -2) NEW 3 5/8 M.S. WITH 5/8" GYP. BD. BOTH SIDES FINISH PER ALUM. REVEAL BY TENANT BY L.L. FINISH FLOOR EXISTING COUNTER RECONFIGURE EXISTING COUNTER 3/4" BY TENANT NEW 3 -5/8 M.S. WITH 5/8" GYP. BD. BOTH SIDES FINISH PER QTB -1) NI RECEIVED JUN 05 2012 PERMIT CENTER DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: U LL LLI 0 V I z U FLI2 =z LLI = U O z D 0 Ln (0 REVISIONS WA 98188 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON STOREFRONT ELEVATIONTS AND SECTIONS SHEET NUMBER O F. 5 NEW HAND SINK EXISTING ( T -2 COVERED BY HOOD SCALE: 3/8" = 1' -0" OPEN TO KITCHEN S /STEEL PANELS S/S PANELS HOOD ELOCATED \\ OPEN S /STEEL PANELS 000000 16 0 0 0 • • 3/4" (GR -1) (QTB 1} BASE, TYP. �c- SNEEZE GUARD LIGHT 1/2" TEMP GLASS SILICONE BUTT -JOINT (GR -1) WOOD BLOCKING (GR -1) 3/4" PLYWOOD LIGHT COVE SEE LIGHTING SCHEDULE CONT. STAINLESS STEEL ANGLE FOR SUPPORT STAINLESS STEEL BASE PT 2X SUPPORTS 6" SCALE: 1 -1/2" = 1' -0" EXISTING I' GYP.BD. 6" METAL STUDS BLOCKING. LCD SCREEN BRACKET MOUNTED ON PLYWOOD. 5/8" GYP. BD. TYP. 'X' FINISH TO MATCH ADJACENT. • 1 Y V 1 V PROVIDE ACCESS TO ALL REQUIRED WIRING, COORDINATE WITH OWNER FOR LOCATION. S/S J CHANNEL FOR GLASS SUPPORT 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 2 2012 City of Tukwila BUILDING DIVISION 3/4" GAP AROUND MENU BOX MENU BOX SHALL COME WITH A REMOVABLE BLACK METAL FRAME TO HIDE GAP AND TO FLUSH WITH FACE OF GLASS. 3/4" F.R.T. PLYWOOD OVER GYP. BD. PAINT PLYWOOD BLACK. RECESSED MENU BOX 1 -1/2" S/S ANGLE AROUND OPENING 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING SCALE: 1 -1/2" = 1' -0" DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: WA 98188 REVISIONS 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 Q ECEIVEC JUN 05 2012 PERMIT CENTER REGISTERED ARCHITECT DAVID W.HIATT STATE. OF WASHINGTON SECTIONS AND DETAILS SHEET NUMBER 0 F.5 T.�` � `Ly. tr y: -Y� VERIFY SIZE WITH EQUIP. SUPPLIER J' COLD /HOT WELLS SEE EQUIPMENT PLAN WHITE PLASTIC LAMINATE r TO EXISTING FLOOR SINK d 17- (QTB 1} BASE, TYP. �c- SNEEZE GUARD LIGHT 1/2" TEMP GLASS SILICONE BUTT -JOINT (GR -1) WOOD BLOCKING (GR -1) 3/4" PLYWOOD LIGHT COVE SEE LIGHTING SCHEDULE CONT. STAINLESS STEEL ANGLE FOR SUPPORT STAINLESS STEEL BASE PT 2X SUPPORTS 6" SCALE: 1 -1/2" = 1' -0" EXISTING I' GYP.BD. 6" METAL STUDS BLOCKING. LCD SCREEN BRACKET MOUNTED ON PLYWOOD. 5/8" GYP. BD. TYP. 'X' FINISH TO MATCH ADJACENT. • 1 Y V 1 V PROVIDE ACCESS TO ALL REQUIRED WIRING, COORDINATE WITH OWNER FOR LOCATION. S/S J CHANNEL FOR GLASS SUPPORT 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 2 2012 City of Tukwila BUILDING DIVISION 3/4" GAP AROUND MENU BOX MENU BOX SHALL COME WITH A REMOVABLE BLACK METAL FRAME TO HIDE GAP AND TO FLUSH WITH FACE OF GLASS. 3/4" F.R.T. PLYWOOD OVER GYP. BD. PAINT PLYWOOD BLACK. RECESSED MENU BOX 1 -1/2" S/S ANGLE AROUND OPENING 1/4" BACK PAINTED TEMP GLASS 1 -1/2" S/S ANGLE AROUND OPENING SCALE: 1 -1/2" = 1' -0" DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: WA 98188 REVISIONS 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289.3332 Q ECEIVEC JUN 05 2012 PERMIT CENTER REGISTERED ARCHITECT DAVID W.HIATT STATE. OF WASHINGTON SECTIONS AND DETAILS SHEET NUMBER 0 F.5 • i r ani a -... •. „rN • INSkALL120* OUTLET FOR FI ELECT T WELL ?F I • INSTALL 120V GFI ELECT OUTLET FOR SNEEZE GUARD LIGHT INSTALL 120V '• I °' 25 AMP GFI ELECT OU�`I hj1, FOR SAND. PRESS r1 r___ • •,s � INSTALL 120V 20 AMP GFI ELECT OUTLET FOR COLD WELLS INSTALL 208V 20 AMP GFI ELECT OUTLET FOR HOT WELLS ! j o r t EXISTING 1 MODIFIED ELECT. lVIN EXISTING ELECTRICAL SYSTEM (PANELS, XFRMR., RECEPTACLES, LU'GHT FIXTURES, ETC.) TO REMAIN. RECONNECT NEW EQUIPMENT TO SPARE CIRCUITS ON ;EXISTING LOW VOLTAGE PANEL. VERIFY THE ELECTRICAL RATING FOR ALL NEW REPLACED EQUIPMENT. " {: te..- �. ,,.,,.... v; .\ \resat, , •rax\,.,•N ti II /fi 1 ..1.,. EjF _ E DO t =3 1 _ ] 0 HYAC NOTE: EXISTING HVAC SYSTEM TO REMAIN ? f _ r ? ' • I „ „„ EXISTING MOP SINK I f, ? i I 1 / ? t f r r ri I f ? ? I I f f f ? ? rr I ,r i ? I • r „ i • ? r e r •� `� r r , ", i r ? ? ? r 3 i EXISTING ICE •MACHINE yam=' XISTING Pti HAND :1:1t, t SINK it EXISTING WATERl�1EATER � 3 NEW COLD WELLS 3 EXISTING 3 COMP SINK T REMAIN ? !I Z ri I i11 a! 1 EXIST s- ! p! ?\_z #`' o =i1 PREP INK TC REMAI NEW HOT WELLS n NEW HAND SINK. INSTALL 1/2” CPL 'AND -HOT WATER AND CONNECT TO EXISTING COLD AND HOT " „. WATER AT THIS LOCATION. PROVIDE AND INSTALL 1 -1/2” IDIRECT DRAIN LINE TO FLOOR SINK UNDER PREP SINK. V4> .- fk• EXISTING SODA MCHINE EXISTING FLOOR SINK, NEW HOT WELLS AND COLD WELLS TO BE INDIRECTLY DRAINED TO EXISTING FLOOR SINK NOTE: EXTEND GAS LINE TO RELOCATED COOKING EQUIPMENT AND RECONNECT ACCORDINGLY EXISTING SODA MCHINE RELOCATED DROP IN HAND SINK. INSTALL 1/2" COLD AND HOT WATER AND CONNECT TO EXISTING COLD AND HOT WATER AT THIS LOCATION. •,., PROVIDE AND INSTALL 1 -1/2" IDIRECT DRAIN LINE TO PL'OOR SINK UNDER PREP SINK. EXISTING 1 MODIFIED PW$ING KAN UNLESS NOTED OTHERWISE ON PLANS, ALL PLUMBING (FLLOOR DRAIN, FLOOR SINKS, VENTS, WASTE LINES, C/W LINES, H/W LINES, WATER HEATER,' ETC.) ARE EXISTING TO REMAIN. CONTRACTOR TO VERIFY THE CONDITION OF ALL OF THE ABOVE AND REPORT FINDINGS TO OWNER AND ARCHITECT. RECONNECT RELOCATED EQUIPMENT AND PLUMBING FIXTURES TO EXISTING PLUMBING AND WATER SYSTEMS. MECHANICAL CONTRACTOR IS TO VERIFY CONDITION OF EXISTING HVAC UNIT TO BE REUSED AND VERIFY ALL COMPONENTS (I. E. FAN MOTORS, COMPRESSOR, HEATING COILS, THERMOSTATS AND CONTROL DEVICES, ETC.), PERFORM ALL NECESSARY TESTS TO ASCERTAIN SYSTEM IS IN GOOD WORKING ORDER AND INSURE UPON HIS INSPECTION THAT UNIT AND ALL COMPONENTS WILL BE WARRANTED FOR A MINIMUM OF 90 DAYS FROM DATE OF CERTIFICATE OF OCCUPANCY OR WHEN STORE OPENS, WHICHEVER IS LATER. MECHANICAL CONTRACTOR IS TO PROVIDE A WRITTEN REPORT OF ALL TESTS PERFORMED, ALONG WITH HIS RECOMMENDATIONS ON THE EQUIPMENT TO OWNER CORPORATION. MECHANICAL CONTRACTOR SHALL COORDINATE WITH OWNER AND RELOCATE EXISTING EXHAUST HOOD TO LOCATION SHOWN ON PLAN. RECONNECT ALL EXHAUST / MAKEUP AIR DUCT WORK TO EXISTING DUCT. ALL WORK SHALL COMPLY WITH ALL CODES AND LANDLORD REQUIREM ENT. NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS INSTALL PER MANUFACTURES PRODUCT LITERATURE. "PRODUCT DATA” 3" MINIMUM OVERLAP (TYP = LONGITUDINAL OR TRANSVERSE JOINTS) 3M FIRE BARRIER DUCT WRAP 615+ BLANKET FOR GREASE DUCT ENCLOSURE ASSEMBLIES 2 LAYER = 2 HOUR ESR #1255 2 HOUR RATED ASSEMBLY. — 16 GA. GREASE DUCT NOTE: PROVIDE SIMILAR CONSTRUCTION AROUND HOOD CONT. WELD NOTE: FIELD APPLIED OP. FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE LATEST MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS LISTING. ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE SEALED PER THE MANUFACTURER'S RECOMMENDATIONS. ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION. AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOB SITE. RATED FIRE p SCALE: N.T.S. bt). 1410 DATE: 4 -26 -12 JOB NO: 1219 DRAWN: CHECKED: REVISIONS SEATTLE WA 98188 4410 W. MELROSE AVENUE TAMPA, FLORIDA33629 TEL. 813.333.2717 FAX. 813.289'3332 RECEIVED JUN 05 2012 PERMIT CENTER REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON MECH., ELECT. & PLUMBING MODIFICATIONS SHEET NUMBER MEPJIF1