HomeMy WebLinkAboutPermit D12-197 - FULTZ RESIDENCE - UPGRADESFULTZ RESIDENCE
12522 50 PL S
D12 -197
Parcel No.:
Address:
Suite No:
Project Name:
City Alt Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #I00
Tukwila, Washington 98188
Phone: 206 -43 1 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
0179002635
12522 50 PL S TUKW
FULTZ RESIDENCE
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D12 -197
07/27/2012
01/23/2013
Owner:
Name:
Address:
FULTZ PATRICK +LAUREL
12522 50TH PL S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: S K M CONSTRUCTION INC
Address: 14415 SE 143 PL , RENTON, WA 98059
Contractor License No: SKMCOI *052L3
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 425 235 -5569
Expiration Date: 12/30/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $25,860.00
Type of Fire Protection: NONE
Type of Construction: V -B
Electrical Service Provided by: SEATTLE CITY LIGHT
Fees Collected:
International Building Code Edition:
Occupancy per IBC:
$993.76
2009
0022
* *continued on next page **
doc: IBC -7/10
D12 -197 Printed: 07 -27 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
Start Time:
Volumes: Cut 0 c.y.
Size (Inches): 0
End Time:
Fill 0 c.y.
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N , Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: _L
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit
Signature: c J _ 1� l� l�n c �� Date: ` l o2Z(
Print Name:
i (ra L 1 1 1. Ci' c.SzY�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread
index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed
spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply
to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or
floor finish.
doc: IBC -7/10
D12 -197 Printed: 07 -27 -2012
6: All construction shall be done in conforce with the approved plans and the requires of the International
Building Code or International Residentia e, International Mechanical Code, Washin tate Energy Code.
7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -197 Printed: 07 -27 -2012
CITY OF TUKWILA"
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.lva.us
Building Perm N°.
Mechanical Permit No.l
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 12522 50th PI. S.
Tenant Name: Patrick and Laurel Fultz
Property Owners Name: Patrick and Laurel Fultz
Mailing Address: 12522 50th Pl. S.
King Co Assessor's Tax No.: 0179002635
Suite Number: Floor:
New Tenant: ❑ Yes 10 ..No
Tukwila
City
WA 98178
State Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:.
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
State
Zip
Contractor Registration Number: Expiration Date:
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Zip
Contact Person:
E -Mail Address:
H:Wpplications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
City
Day Telephone:
Fax Number:
State
Page 1 of 6
BUILDING PERMIT INFO
Valuation of Project (contractor's bid price): $ 25,860 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an. Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department. ,
H:Wppltcattons\Forns- Applications On Lme\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1St Floor
992
2nd Floor
3"d Floor
Floors "` thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an. Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department. ,
H:Wppltcattons\Forns- Applications On Lme\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ { -7 3 LL 0 0
Scope of Work (please provide detailed information):
Use: Residential: New .... ❑ Replacement .."!
Commercial: New .... ❑ Replacement .... ❑
Fuel Type: Electric ❑ Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
.
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
1
l
Wood/Gas Stove
30-50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig /Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm /Ind
H:Wpplicattons\Fotms- Applications On Ltne\2009 Applications \I -2009 - Pettit Apphcation.doc
Revised: 1 -2009
bh
Page 4 of 6
PUBLIC WORKS PERMIT IARMATION — 206 - 433 -0179
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑...Water District #125
❑ ...Water Availability Provided
❑ .. Highline
Sewer District
❑ ...Tukwila 0... Valley View ❑ .. Renton
❑ ...Sewer Use Certi ate 0... Sewer Availability Provided
Se tic System:
0 On -site Septic System For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application , ark boxes which apply):
❑ ...Civil Plans (Maximum P er Size — 22" x 34 ")
❑ ...Technical Information Repo Storm Drainage) ❑ .. Geo nical Report ❑ ...Traffic Impact Analysis
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. tenance Agreement(s) 0... Hold Harmless — (SAO)
0... Hold Harmless — (ROW)
❑ .. Renton
❑ .. Seattle
Proposed Activities (mark boxes that ap
❑ ...Right -of -way Use - Nonprofit for less th.. 2 hours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
.. Right -of -way Use - Profit for less than 72 hours
.. Right -of -way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer ❑ .. Ab. • on Septic k ❑ .. Grease Interceptor
❑ ...Cap or Remove Utilities ❑ ..c . Cut ❑ .. Channelization
❑ ...Frontage Improvements ❑ .. % ement Cut ❑ .. Trench Excavation
❑ ...Traffic Control ❑ ooped Fire Line ❑ .. Utility Undergrounding
❑ ...Backflow Prevention = Fire Protection
Irrigation
Domestic Water "
❑ ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # 0... Deduct ` er Meter Size "
❑ ...Sewer Main Extension Pu s lic ❑ Private ❑
❑...Water Main Extension Public ❑ Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line
❑...Water ❑...Sewer
Monthly Service Billing to:
Name:
Number of Public Fire Hydrant(s)
❑ ...Sewage Treatment
Day Telephone:
Mailing Address:
State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
City
Day Telephone:
City
State Zip
H:\Applications\Fotms- Applications On Lute \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 3 of 6
PERMIT.APPLICATION NOTES — Applicable to all permits in • this' application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable, cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW ' E SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR A T ,�� ED AGENT:
Signature:
Print Name: Tim
Date:
y J. 'enlas ?j, SM Stemper Architects, PLLC
Mailing Address: 4000 Delridg
ay SW, Sui 'L200
1
Day Telephone: (206) 624 -2777
Seattle
6./0
WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:Wpplicattons\Forns- Applications On Lux \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPIN•ERMIT INFORMATION — 206 -4370
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's 'd price): $
Scope of Work (please provide deta -d information):
Building Use (per Int'l Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
Se r:
Indicate type of plumbing fixtures and/or gas piping outlets : g installed d the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
ixt • Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
■ • s washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
. od- . ste grinder,
omme .'.1
Floor Drain
Shower, single head trap
Lavatory
Wash fou 'n
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste trea -nt
interceptor, including t •
and vent, except for kitch,
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration • '
water piping and/or ater
treatment equipm-
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
.ecific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow prote e
device other the
atmospheric- pe vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
-
• h lawn sprinkler
sy on any one meter
inclu. ing backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications \Forms - Applications On- Line\2009 Applications \1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
Cif of Tukwila. •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http://www. ci. tukwila.wa. us
SET RECEIPT
RECEIPT NO: R12 -01839
Initials: WER
Payment Date: 06/11/2012
User ID: 1655 Total Payment: 9,571.97
Payee: PAMELA KUEHL
SET ID: 0611 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D12 -196 1,067.51
wIngocoommommommtmanu
D12 -198 1,635.20
D12 -199 1,856.13
D12 -200 905.73
D12 -201 779.67
D12 -202 1,141.27
M12 -089 167.70
M12 -090 167.70
M12 -091 177.10
M12 -092 177.10
M12 -093 167.70
M12 -094 167.70
M12 -095 167.70
TOTAL: 1,067.51
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 9,571.97
TOTAL: 9,571.97
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
MECHANICAL - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
000.345.830
640.237.114
TOTAL:
5,059.25
1,192.70
3,288.52
31.50
9,571.97
INSPECTION RECORD
Retain a copy with permit
1D12 -19-7
INSPECTION NO. PERMIT NO. fe
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
E U 1~ Z .c-5
Type of Inspection:
Qco ► al C+ vsl (4110.511 L
Address:
1 2522, SO PL S
Date Called:
i- s 6. JAL.
Special Instructions:
�} I _ (' /
Q ` rf✓ ( t �
/7
f *
Date Wanted:.
i
,EANI wow UW)
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: 012 -197
PROJECT NAME: FULTZ RESIDENCE
SITE ADDRESS: 12522 50 PL S
X Original Plan Submittal
Response to Correction Letter #
DATE: 06 -08 -12
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
IIQIn vision
Fire Prevention
Public Works ❑ Structural
Planning Division
Permit Coordinator
n
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
DUE DATE: 06-12 -12
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
n
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
rs
DUE DATE: 07 -10 -12
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople inter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEt1 to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name S K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pl License No. SKMCOI'052L3
Suite /Apt. License Type Construction Contractor
City Renton Effective Date 6/23/1995
State WA Expiration Date 12/30/2013
Zip 98059 Suspend Date
County , King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMCO "093L6
S K M
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI'976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NATL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.0004/26
/2010
4
DEVELOPERS SURETY
Et INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.0012/05
/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
15
James River Ins
00049593
08/21/2011
08/21/2012
$1,000,000.00
08/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.00
08/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.00
01/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.00
01/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
8
AMERICAN
STATES INS CO
01CD87273810
12/30/2005
12/30/2006
$1,000,000.00
12/06/2005
https: // fortress .wa.gov /lni /bbip /Print.aspx
07/27/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO711C12 BID PACKAGE M -30
3- 53- 0058 -044
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED TO:
APPLICABLE
YES N O
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL- FRAMED ACOUSTICAL WINDOWS.
X
1. GUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL OF EXISTING OPENING.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
B. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION MD
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL SERVICE.
X
20. KNOB AND TUBE WIRING.
X
FE,
oamyt9
approval is subject to errors and omissions.
1 « 1S. , n documents does not C.I Ehcr`z9
, : • adopted code or ordinance. Racel.pt
1.1 t_.; ,< � OopY and conditions is acknowledged:
D
C\t
Yd 3,
City Of Tukwila
BUILDING DIVISION
} 5 r'art"" RYtC
? o the `pp¢ONS
ff -°: "`;;;17- ier cEpprOVF1 >f
ng Divrw
. ZIY,iro a R ^;`s t:` - i
^n F Jbrn al
cc t" eVIP .
•...t�2'v...,:�iV;ia1 Wan i... � I fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Planning Pivision
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
international Mechanical Code
ZONING: SF1200
OCCUPANCY: (No Cha�nQe)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
v 8 NON SPRINKLERED
0119002635
LEGAL DESCRIPTION:
LOT(S) 69,10,11 AND12, BLOCK 12, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF
RECORDED N VOLUME 12 OF PLATS, PAGE(8) 100, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF
KING, STATE OF WASHINGTON.
DRAWING INDEX
T0.0
A1.0
42.0
42.1
A22
42.3
TITLE SI -SET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX
M2.0 MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
E1.1 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206. 2%.0190
Contact: Sharyn Parker
E- mail: 5haryn.Parker•kingcounty.gov
ARCHITECT:
S.M. Stamper Architects PL.L•G.
4000 Pelridge Way SW, Suite 200
Seattle, WA 58106
Ph: 206. 624. 21TI
Fax: 206.624.2513
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: ,Jerryssmstemper.com
melodyssmstemper.com
timasmstemper.com
ACOUSTICAL ENGINEER
55A Acoustics
222 Etruria Street, Suite 100
Seattle WA 58105
Ph: 206. 535. 0515
Fax: 206.535.0524
Contact: Mohamed Alt Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98115
Ph 206. 318. 0565
Fax: 206. 318. 0641
Contact: Dylan Turner
E -mail: DylanTegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcrstresweat.com
REGULATED MATERIALS:
P55 Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 58102
Ph: 206. 232. 5635
Fax: 206.162. 4180
Contact: Tim Ogden
E -mail: tim ogdenapbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 1200
Easton, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: CMaedasjonespayne.com
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 55121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E -mail: ronnspsm- engineers.com
JUN 08 2012
VICINITY MAP (NTS)
s.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 r)ELRIIDGE WAY SW
SUITE 20C • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.2131
3/1/12
.EVRER
iiINGTON
0
a_
J
Q
z
0
z
z
z
0
U
z
MPROVEMENTS
O
W
W
W
co
0
ce
z
CA
AIP NUMBER
3 -53- 0058 -044
z
0
z_
C1}
Q
J
DATE
311/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.21
FUR
CRAWL
SPACE
LOWER FLOOR PLAN
1/4 " =1' -0"
SPECIAL NOTES:
NOTES:
I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PANT.
G
LAUNDRY
ROOM
L I V INCA
ROOM
GENERAL NOTES
1 CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER 51-IALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 .4M EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW I5 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 P11.
6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
1. ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WNDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHNG DETAILS SHEET FOR WINDOW REPLACEMENT.
. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. NSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
11. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND /OR MECI -L COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVNG AS REQ'P AND RE- CONSTRUCT
SHELVING IN COORDNATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
I. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
I. CONTRACTOR 15 TO VERIFY CHAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUM POWER OUTAGE 15 EIGHT HOURS. POWER MUST 8E PROVIDED AT RESIDENCE BEFORE &00 AM 4 AFTER 5:00 PM.
MAIN FLOOR PLAN
1/4" = 1' - 0"
A. WEST ELEVATION
14' -4"
14' -0"
L
II
'I
1r
11
I,�
`I
IF
TYP.
III
Ili
011
II I
I �
I I
1
N L
- r--
-: - =r-1
... r.......
r
01,
i
i
i
9' -2"
__7
= 1 ` -a
_ 14° x ;4 ".EXLST. 4 0
ATTIC ACCESS a 1
PANEL ; I
1
1
III
I
1
•
r--. I
ly
I
1
1
1
1 ] LJ
11
11
I�
L'
c
L
B. NORTH ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
0 2 DEMOLISH EXISTING DOOR(5), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
��..// DOOR SCHEDULE.
O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1 /422 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
G DEMOLISH EXISTING DOOR(5), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A2.1. FLUSH SOLID CORE NTERIOR WOOD DOOR
WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET.
CD BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND
DISCONNECT. REF. 3/A22 FOR DETAIL.
® COORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS.
c:: INSTALL VENT BAFFLE(5) AT EXISTING GABLE END VENT(S) N ATTIC. REF. 4/422 FOR DETAIL.
ONSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS.
0 DEMOLISH EXISTING PANEL, USE AS JUNCTION BOX. COORDINATE WITH ELECTRICAL DOCUMENTS.
10 NEW ELECTRICAL SERVICE REQUIRED. INSTALL NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
ATTIC PLAN
1/4" = 1' - 0"
C. EAST ELEVATION
J
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
LEGEND
D. SOUTH ELEVATION
1
E
A
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER At A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR AttIC PANEL
AND WHOLE MOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT. •,.
▪ REF. GENERAL NOTE 11
ATTIC INSULATION
JUN 08 2012
•
INSTALL BATTERY OPERATED SMOKE
DETECTORS
SC INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.2131
3/1/12
0
J
z
O
I—
z
w
z
H
z
0
U
00
z
AIP NUMBER
MPROVEMENTS
3 -53- 0058 -044
z
0
z_
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
FLOOR
PLANS
NOTES
A1.0
0810.03.2131
WINDOW TYPES
1.
HORIZONTAL
XX SLIDER
2.
3.
CASEMENT SLIDER/ FIXED/ SLIDER
4.
HORIZONTAL
SLIDER / FIXED
WINDOW SCHEDULE
WINDOW
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
REMARKS
DETAIL SET
A
BEDROOM 1
1
4' -7" x 4' -5"
STAIN /PAINT
SAFETY GLAZING REQUIRED
1/A2.0
B
BEDROOM 2
1
4' -10" x 1' -10"
STAIN /PAINT
CUT DOWN SILL TO 40" AFF. FOR EGRESS (E) SILL
HT. 58"
2/A2.0
C
OFFICE
1
3' -9" x 1' -9"
STAIN /PAINT
1/A2.0
D
KITCHEN
1
3' -5" x 1' -11"
STAIN /PAINT
SAFETY GLAZING REQUIRED
1/A2.0
E
KITCHEN
2
2' -3" x 4' -5"
STAIN /PAINT
1/A2.0
F
KITCHEN
4
5' -1" x 4' -4"
STAIN /PAINT
1/A2.0
G
LIVING
3
5' -0" x 4' -5"
STAIN /PAINT
1/A2.0
H
LIVING
3
5' -0" x 4' -5"
STAIN /PAINT
1/A2.0
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
SLOPE
I" min.
I " min.
L END CLOSURE
f
I
HEMMED EDGE J
HEAD FLASHING DETAIL TYP.
3 " =1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF- ADIWIERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PRE- PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF - ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
(E) GIJJ5
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
CONTINUOUS
SEALANT, TYP.
OLID WOOD TRIM
IUD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
REMOVE (E) WD. SIDING FOR
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
UJALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
UJALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
WINDOW HEAD
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
(E) GWB
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
SACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW JAMB
WD JAMS LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
�3/4"
3/4" WD. SILL - STAIN TO
MATCH (E)
WINDOW SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TTP.
SELF- ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
(E) IUD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF- ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
FRE- PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WD. SIDING FOR
(E) GUJ5
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENNG FRAMNG. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PANT MODIFIED SIDING
TO MATCH (E) SIDING
(E) IUD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
WINDOW HEAD
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4 SEALANT
ACOUSTICAL WNDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN ----___
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW JAMB
(E) GWB
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WINDOW SILL
SILL HEIGHT
40" AP
3/4" WD. SILL - STAIN TO
MATCH (E)
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
(2) 2X SILL PLATE
SELF- ADHERING
MEMBRANE
(E) GWB
1)1-1%1'17
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
JUN 08 2012
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
1
3/1/12
0810.03.2131
O
0
J
z
O
z
z
1—
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
0
w
w
w
0
z
H
Z
W
cn
3 -53 -0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2131
DOOR TYPES
O
,A
FLUSH SCW
INTERIOR
PULL LITE,
W/ SAFETY GLAZING
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ OBSCURE
SAFETY GLAZING
W/ OBSERVATION PORT
c
EXTERIOR
SINGLE LEAF
STORM W/ SAFETY
GLAZING
DOOR SCHEDULE
DOOR NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH INT. /EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK SET
DETAIL SET
1
LIVING
A
2' -8" x 6' -8"
STAIN /STAIN
HW -1/613
DK -2
LOCK -1
1/A2.1
2
KITCHEN (INTERIOR)
g
2' -6" x 6' -8"
STAIN /STAIN
HW -1/613
DK -3
2/A2.1
3
LIVING
C
2' -8" x 6' -8"
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT
ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT
CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS
SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
I" min.
1/1" min.
HEMMED EDGE J
SLOPE
L —J
END CLOSURE
E
C.4
HEAD FLASHING DETAIL TYP.
3 " =1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF - ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) UJOOD SIDING FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM. REPLACE OR RE INSTALL
SIDING A5 REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE - PRIMED, GALV SWEET METAL
FLASHING W/ END CLOSURE UNDER
SELF- ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
SELF- ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
514111 AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER -
STRIPPING
DOOR PER SCHEDULE
2" MIN.
REMOVE (E) W. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDING TO POOR OPENING FRAMNG.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHING. NSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDNG JOINTS 4 SET NAIL
HEADS FLUSH. PANT MODIFIED SIDNG TO
MATCH (E) SIDING
DOOR HEAD
(E) WOOD SIDING
CONTINUOUS SEALANT BEHND
z BAR FRAME
STORM DOOR PER SCHEDULE
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER - STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR JAMB
(E) EXTERIOR 514EATHING
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMNUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
DOOR SILL
CONTINUOUS
SEALANT, TYP.
EXISTING FRAMING
5OLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 "= 1' -0"
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATI -ER
STRIPPING
KERF N CONTINUOUS
WEATHER STRIPPING
SHIM AS NECESSARY
FILL GAP W/ BAIT
INSULATION
BACKER ROD AND SEALANT
SOLID WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
DOOR HEAD
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
INTERIOR DOOR PER
SCHEDULE
KEW IN CONTINUOUS
WEATHER STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR SHOE
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
EXISTING FLOOR STRUCTURE
DOOR JAMB
DOOR SILL
EXISTING FRAMING
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
POOR PER SCHEDULE
INTERIOR - DOOR DETAIL SET
3 " =1' -0"
p1)--1q7
I, /l tr;!E¢ FOR
iMPLIANCE
ROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
JUN 08 2012
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
3/1/12
0810.03.2131
i-
ce
O
0
ce
J Q
z
O
1--
z
w
1—
z
i-
z
0
0
0
z
AIP NUMBER
MPROVEMENTS
3 -53 -0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2131
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF- ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE - PRIMED, GALV. SHEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF- ADI -IERNG MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR TO
BE SELECTED IN THE FIELD
PAINT VENTILATION FIXTURE,
COLOR TO BE SELECTED IN
714E FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH: PANT NTERIOR W/
ACOUSTICAL DAMPNG
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
1
(E) WALL UNDERLAYMENT
SELF-ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
3 "= 1' -0"
C�
BLENDING AIR UNIT DETAIL
1 1/2" = 1' - 0"
SUSPEND MECH UNIT FROM (E)
STRUCTURE R1=: MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
EXISTING ROOF
(E) ROOF FRAMING
INSULATION DAM DETAIL
3 "= 1' -0"
EXIST. WALL
CONSTR
(2) SIMPSON A -34
• EACH SIDE PANEL
EXIST. GABLE
VENT
NEW " GALV
14ARDWARE
CLOTH
;" CDX PLYWOOD
AT (3) SIDES
BLOU• IN CELLULOSE
INSULATION WITH A COMBINEI
VALUE OF NOT LESS THAN
R -3S
INSULATION DAM
(E) WALL FRAMING
1" OWENS CORNING 1103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
SACK AND SIDE PANEL
NOTE:
I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
GABLE END VENT BAFFLE DETAIL
1 1 /2" = 1' - 0"
rri
REVIEWED FOR
CODE COMP!. LANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
JUN 08 2012
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DFLRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624 -2973
0810.03.2131
3/1/12
0
0
J z
< ww 0
I— E
Z w C!)
z Q
z F J
LJ
z
U
0 Et
U <
0
_Z Q
z
w
0
(1)
w
MPROVEMENTS
AIP NUMBER
3 -53 -0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
MISC.
DETAILS
A2.2
0810.03.2131
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. PLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
.--(E) SHEATHING
12"
LAP SILL MEMBRANE
FLASHING 2 -1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND I i" BEYOND
RO. AT EA END OF
SILL.
(E) BLDG.
PAPER AT
SILL
CUT SILL
FLASHING E FOLD
THROUGH R.O. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
MIN
" TYP.
BUTTERFLY CORNER FLASHING
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 51•IOUN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
ELEVATION VIEW` -�
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
(7
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOILN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
L
J
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWINCI STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT J4113 FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
N
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
0
INSTALL 514T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW 1 /5" LEARANCE
4 p..r,: t }' ` "> BETWEEN FL RING AND
1301. EDGE • (E)
SIDING.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO_ AT HEAD
AND JAMBS.
MEMBRANE FLASHING AT HEAD
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
O
0 0
6 WINDOW FLASHING INSTALLATION
K SCALE: NTS
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
C9
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4 " -3/5" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
API-FEARING MEMBRANE FLASHING" TYPICALLY
REFEREP TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
51-1IMMED, AND ANCHORED.
4: DETAILS "-1 AND S" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS.
bt,iqi
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
JUN 08 2012
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
3/1/12
rX
O
0-
—J
z
0
z
w
z
1—
Z
0
0
0
z
MPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2131
O
O
O
G
C
O
O
0 0 0
ELEVATION VIEW` -�
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
(7
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOILN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
L
J
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWINCI STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RD. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT J4113 FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
N
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
0
INSTALL 514T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW 1 /5" LEARANCE
4 p..r,: t }' ` "> BETWEEN FL RING AND
1301. EDGE • (E)
SIDING.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO_ AT HEAD
AND JAMBS.
MEMBRANE FLASHING AT HEAD
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
O
0 0
6 WINDOW FLASHING INSTALLATION
K SCALE: NTS
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
C9
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE I/4 " -3/5" GAP
BETWEEN WINDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
API-FEARING MEMBRANE FLASHING" TYPICALLY
REFEREP TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
51-1IMMED, AND ANCHORED.
4: DETAILS "-1 AND S" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS.
bt,iqi
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
JUN 08 2012
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
3/1/12
rX
O
0-
—J
z
0
z
w
z
1—
Z
0
0
0
z
MPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2131
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SRC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEIUNG
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STA11C PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDI11ONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SEATTLE RESIDENTIAL CODE
SCREENED OPENING
STA11C PRESSURE
STA11C PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STA11C PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
0
ABBR
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
�- DIRECTION OF FLOW
OR XSx EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
X/Y
%/////////,
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL
SG -X
XXX
ABBR
0 ->
041-
DN
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
® OR ® THERMOSTAT
EQUIP ID# O EQUIPMENT LOCATION
I
NG
•
0
D'a
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 4
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STA11C
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
165
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
3
SG -1
165
<08" WG
8"
8"
CEIUNG
ALLGRILLE
1, 2, 4
0G -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3
RG -1
25
<08" WG
4"
4"
CEIUNG
DECO
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2131
913
3
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
bl� -I�i7
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -51, SECTION M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE M1508.2) 45_
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1 /2) = 90 CFM
S.M. STEMPER
ARCHITECTS
A Proteadonal Limited Liability Company
4000 DELRIDGE WAY SW
STATE 200 • SEATTLE, WA 98108
(200) 624 -2777 • FAX (206) 024 -2973
THE GREENBUSCH GROUP, INC
. •a.....)
))
1 9111E 201 SEAM 115 N119
(206) 378 -0009 (206) 376-0641 FAX
EXPIRES: 9/08/2012
0810.03.2131
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3- 53- 0058 -044
TUKWILA WASHINGTON
DATE
3/1/2012
ISSUED GROUP 21 100%
JUN 0 8 2012
KIWI AND
APPROVAL
REQUIRED
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.2131
NO MECHANICAL WORK THIS LEVEL
STORAGE
FUR
CRAWL
SPACE
LOWER FLOOR MECHANICAL PLAN NORTH
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
HOLD 'TIGHT TO
STRUCTURE
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE ACCESS
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
ATTIC
MOTOR ACCESS
FILTERS ACCESS
BLENDING UNIT INSTALLATION DETAIL
SCALE: NONE
SEE m2.0 TYP ALL
CEILING GRILLES
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
MAIN FLOOR MECHANICAL PLAN NORTH
2 SCALE: 1/4" = 1' -0"
DUCT PER PLAN
2X BLOCKING
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
2X BLOCKING
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
SCALE: NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON
GRILLE
r
E
4 "0 DN
L TO RG -1
1 14' x 24' EXIST.
ATTIC ACCESS
PANEL 4 "0
4 "0
4 "0 DN
TO RG -1
n
—J
I I
1 LJ
I
- - - -_� I__�
DUCT PER PLAN
COORDINATE SOFFIT
WITH TECHNICAL
REPRESENTATIVE
C _J
ATTIC MECHANICAL PLAN NORTH
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR OR CEILING JOIST
CEILING
SCALE: 1/4" = 1' -0"
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
SCALE: NONE
1.
DRAWING NOTES:
FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY
OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC
51 -51, SECTION M1508.6.6.
2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK -OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR
UNIT SYSTEMS WITH NEW FILTERS.
FLAG NOTES:
1).--197
13V -1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND
MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL
SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER
THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING
INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.6.4.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE
MAKING FINAL GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR
INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
JUN 08 2012
SEPARATE
PERK" AND
APPROVAL
REQJhRED
S.M. STEMPER
ARCHITECTS
A Prateeeional limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(20e) 824 -2777 • TAX (206) 824 -2076
THE GREENBUSCH GROUP, INC
0414114 41111100
)))
110:5 weir 1 CI SLW ! EIEE c201 =TIE GWA 9e10
(208) 37e -0569 (208) 376 -0641 FAX
1 EXPIRES: 9/08/2012
0810.03.2131
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/2012
TUKWILA WASHINGTON
ISSUED GROUP 21 100%
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2131
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
O PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
® PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
3® HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
PROVIDE NEW METER BASE,
RIGID STEEL MAST,
WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW WEATHER
HEAD, MAST GUYS AND
ANCHORS AT EXISTING
LOCATION. PROVIDE
NEW ROOF FLASHING.
TRIM VEGETATION TO
PROVIDE MINIMUM 36"
CLEARANCE AROUND
SERVICE WIRES PER
SCL REQUIREMENTS.
DEMO EXISTING FUSE TYPE
PANEL. USE AS JUNCTION
BOX. EXTEND EXISTING
CIRCUITS TO NEW PANEL
5Ert,-;RoOM
NEW PANEL. SEE
DETAIL AND PANEL
SCHEDULE
DEMO EXISTING
PANEL. USE AS
JUNCTION BOX.
EXTEND EXISTING
CIRCUITS TO NEW
PANEL
E,4-1-1-4
1\--TO BV -1
:411 E ..FS.
ACCESS
PEA
r-
H
K. T0b =N
w
u
11 I
v)
RTh
O
I E:IROO 1
MAIN FLOOR PLAN
1/4" = 1'
L /,'NG
ROOM
(NORTH
ELECTRICAL LEGEND
WWI_
DESCRIPTION
SYM$OL
DESCRIPTION
G
UGH11NG OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
®
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
111111
�}
DAMPER CONNECTION
Q'
NON -FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
ES'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
SMOKE DETECTOR
El
ELECTRICAL METER
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
UT
THERMOSTAT
— - —
E
CEIUNG MOUNTED FIRE ALARM - VISUAL STROBE UGHT
®
UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15 1 16
N/A
15
16
N/A
REMARKS
BV -1
BLENDING UNIT VENTILATOR
SWITCHES (ON, TIMER)
120
1
X
X
120
X
1,2
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
'411 i 2 EX wi .
T C CCES
tee_
J
L
ATTIC PLAN
1/8" = 1'
C
1
JUN 08 2012
SEPARATE
PERMIT AND
itpPROVAL
REQUIRED
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
■N�INIERS, INO
all SOWN N MliR wln. w�
11101111116 OK M.....
7.1Y. — A MM
rMI MIS wSOB
0810.03.2131
0
a
ce
0
J
f'-'
Q
Z
W
Z
Z
0
U
C�
Z
AIP NUMBER
MPROVEMENTS
5 -53 -0058 -044
SEATTLE WASHINGTON
DATE
MAR 1, 2012
ISSUED
100% CD
PROJECT ENGINEER
CHI
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.2131
PANEL
LOCATION:
SERVING: RESIDENCE
CKT
LOAD DESCRIPTION
TYPE KVA
EXISTING LOAD
3
5 EXISTING LOAD
7 EXISTING LOAD
9 EXISTING LOAD
11 EXISTING LOAD
30/2
2011
13 EXISTING LOAD
15 EXISTING LOAD
17 BLENDING UNIT
19
21
23
LOAD TYPE
CONN. LOAD
H
20/1
120/240 VOLT,
10,00
C,
1 PHASE, 3 WIRE.
200 AMP with MAIN BKR
PHASE NP
A
A
50/2
40/2
20/1 ! A
20/1
3011
30/1
20/1
B
20/1
20/1
20/1
20/1
COMPUTED LOAD
❑ ISOLATED GROUND BUS
❑ ,RAINTIGHT NEMA -3R ENCLOSURE
REMARKS:
[] FEED THRU LU
❑ DOUBLE LUGS
A
PE
LOAD DESCRIPTION
EXISTING LOAD
EXISTING LOAD
EXISTING LO
PROVISION
PROVISION
PROVISION
A
KT
2
4
6
8
10
12
14
16
18
20
TOTAL LOADS
KVA
22
24
P
N BKR SHUNT TRIP
PANEL SKIRTS
❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS
A
❑ SURFACE
❑ FLUSH
P
PROVIDE NEW RIGID STEEL
MAST, WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW MAST
GUYS AND ANCHORS
ROOF
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
FEES PAID BY
CONTRACTOR.
2 "C, 3#3/0 CU
METER AND FINAL
CONNECTIONS BY
SCL. INCLUDE ALL
UTILITY CHARGES IN
BID.
PANEL MP
200A
120/240
1 -PH, 3W
2 "C, 3#3/0 CU.& GND
PROVIDE METER BASE
PER SCL STANDARD
#DU13- 4 /NMT -30
E--- r-PROVIDE #4CU GROUNDING
ELECTRODE CONDUCTOR AND
GROUND RODS PER CODE.
MAX 10 OHMS TO GROUND
■
PROVIDE NEW
NEMA -3R S.E. RATED
PANEL BOARD.
INTERCEPT AND
EXTEND EXISTING
CIRCUITS AND
CONN OT TO NEW
BREAKERS.
PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED
TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON
DRAWINGS.
ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE
STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST.
PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD
CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING
CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS
PRIOR TO BID.
NEW SERVICE DETAIL 1ct
SCALE:NONE
JUN 08 2012
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
■N•INIU11e. INC
NM SOW %M VIM NMI IN
UMW 10224011
'MI✓wO- MM IM MM
111 412 S
0810.03.2131
O
a
Z
0
ce
z
w
z
z
0
0
0
Z
MPROVEMENTS
0
w
2
cn
w
w
0
z
Li
0
SEATTLE WASHINGTON
FLOOR
PLANS
NOTES
E1.1
0810.03.2131