Loading...
HomeMy WebLinkAboutPermit D12-197 - FULTZ RESIDENCE - UPGRADESFULTZ RESIDENCE 12522 50 PL S D12 -197 Parcel No.: Address: Suite No: Project Name: City Alt Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 0179002635 12522 50 PL S TUKW FULTZ RESIDENCE DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D12 -197 07/27/2012 01/23/2013 Owner: Name: Address: FULTZ PATRICK +LAUREL 12522 50TH PL S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI *052L3 Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 425 235 -5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $25,860.00 Type of Fire Protection: NONE Type of Construction: V -B Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $993.76 2009 0022 * *continued on next page ** doc: IBC -7/10 D12 -197 Printed: 07 -27 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N , Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: _L I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit Signature: c J _ 1� l� l�n c �� Date: ` l o2Z( Print Name: i (ra L 1 1 1. Ci' c.SzY� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. doc: IBC -7/10 D12 -197 Printed: 07 -27 -2012 6: All construction shall be done in conforce with the approved plans and the requires of the International Building Code or International Residentia e, International Mechanical Code, Washin tate Energy Code. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -197 Printed: 07 -27 -2012 CITY OF TUKWILA" Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.lva.us Building Perm N°. Mechanical Permit No.l Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12522 50th PI. S. Tenant Name: Patrick and Laurel Fultz Property Owners Name: Patrick and Laurel Fultz Mailing Address: 12522 50th Pl. S. King Co Assessor's Tax No.: 0179002635 Suite Number: Floor: New Tenant: ❑ Yes 10 ..No Tukwila City WA 98178 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address:. City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: H:Wpplications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Page 1 of 6 BUILDING PERMIT INFO Valuation of Project (contractor's bid price): $ 25,860 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an. Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. , H:Wppltcattons\Forns- Applications On Lme\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 992 2nd Floor 3"d Floor Floors "` thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an. Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. , H:Wppltcattons\Forns- Applications On Lme\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ { -7 3 LL 0 0 Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .."! Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper . 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 1 l Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind H:Wpplicattons\Fotms- Applications On Ltne\2009 Applications \I -2009 - Pettit Apphcation.doc Revised: 1 -2009 bh Page 4 of 6 PUBLIC WORKS PERMIT IARMATION — 206 - 433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided ❑ .. Highline Sewer District ❑ ...Tukwila 0... Valley View ❑ .. Renton ❑ ...Sewer Use Certi ate 0... Sewer Availability Provided Se tic System: 0 On -site Septic System For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application , ark boxes which apply): ❑ ...Civil Plans (Maximum P er Size — 22" x 34 ") ❑ ...Technical Information Repo Storm Drainage) ❑ .. Geo nical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. tenance Agreement(s) 0... Hold Harmless — (SAO) 0... Hold Harmless — (ROW) ❑ .. Renton ❑ .. Seattle Proposed Activities (mark boxes that ap ❑ ...Right -of -way Use - Nonprofit for less th.. 2 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards .. Right -of -way Use - Profit for less than 72 hours .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Ab. • on Septic k ❑ .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ ..c . Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. % ement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ ooped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention = Fire Protection Irrigation Domestic Water " ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # 0... Deduct ` er Meter Size " ❑ ...Sewer Main Extension Pu s lic ❑ Private ❑ ❑...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: State Zip Water Meter Refund/Billing: Name: Mailing Address: City Day Telephone: City State Zip H:\Applications\Fotms- Applications On Lute \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 3 of 6 PERMIT.APPLICATION NOTES — Applicable to all permits in • this' application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable, cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW ' E SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A T ,�� ED AGENT: Signature: Print Name: Tim Date: y J. 'enlas ?j, SM Stemper Architects, PLLC Mailing Address: 4000 Delridg ay SW, Sui 'L200 1 Day Telephone: (206) 624 -2777 Seattle 6./0 WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:Wpplicattons\Forns- Applications On Lux \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN•ERMIT INFORMATION — 206 -4370 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's 'd price): $ Scope of Work (please provide deta -d information): Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Se r: Indicate type of plumbing fixtures and/or gas piping outlets : g installed d the quantity below: Fixture Type: Qty Fixture Type: Qty ixt • Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet ■ • s washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) . od- . ste grinder, omme .'.1 Floor Drain Shower, single head trap Lavatory Wash fou 'n Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste trea -nt interceptor, including t • and vent, except for kitch, type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration • ' water piping and/or ater treatment equipm- Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a .ecific gas Each additional medical gas inlets /outlets greater than 5 Backflow prote e device other the atmospheric- pe vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter - • h lawn sprinkler sy on any one meter inclu. ing backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications \Forms - Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cif of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www. ci. tukwila.wa. us SET RECEIPT RECEIPT NO: R12 -01839 Initials: WER Payment Date: 06/11/2012 User ID: 1655 Total Payment: 9,571.97 Payee: PAMELA KUEHL SET ID: 0611 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D12 -196 1,067.51 wIngocoommommommtmanu D12 -198 1,635.20 D12 -199 1,856.13 D12 -200 905.73 D12 -201 779.67 D12 -202 1,141.27 M12 -089 167.70 M12 -090 167.70 M12 -091 177.10 M12 -092 177.10 M12 -093 167.70 M12 -094 167.70 M12 -095 167.70 TOTAL: 1,067.51 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 9,571.97 TOTAL: 9,571.97 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES MECHANICAL - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 000.345.830 640.237.114 TOTAL: 5,059.25 1,192.70 3,288.52 31.50 9,571.97 INSPECTION RECORD Retain a copy with permit 1D12 -19-7 INSPECTION NO. PERMIT NO. fe CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: E U 1~ Z .c-5 Type of Inspection: Qco ► al C+ vsl (4110.511 L Address: 1 2522, SO PL S Date Called: i- s 6. JAL. Special Instructions: �} I _ (' / Q ` rf✓ ( t � /7 f * Date Wanted:. i ,EANI wow UW) PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: 012 -197 PROJECT NAME: FULTZ RESIDENCE SITE ADDRESS: 12522 50 PL S X Original Plan Submittal Response to Correction Letter # DATE: 06 -08 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: IIQIn vision Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator n 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 06-12 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: rs DUE DATE: 07 -10 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople inter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI'052L3 Suite /Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County , King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMCO "093L6 S K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI'976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26 /2010 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.0012/05 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 James River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.00 08/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.00 01/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 8 AMERICAN STATES INS CO 01CD87273810 12/30/2005 12/30/2006 $1,000,000.00 12/06/2005 https: // fortress .wa.gov /lni /bbip /Print.aspx 07/27/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO711C12 BID PACKAGE M -30 3- 53- 0058 -044 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. THE CONTRACT INCLUDES ALL INFORMATION IN THE DRAWINGS AND SPECIFICATIONS INCLUDING BUT NOT LIMITED TO: APPLICABLE YES N O 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL- FRAMED ACOUSTICAL WINDOWS. X 1. GUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENING. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X B. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION MD ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL SERVICE. X 20. KNOB AND TUBE WIRING. X FE, oamyt9 approval is subject to errors and omissions. 1 « 1S. , n documents does not C.I Ehcr`z9 , : • adopted code or ordinance. Racel.pt 1.1 t_.; ,< � OopY and conditions is acknowledged: D C\t Yd 3, City Of Tukwila BUILDING DIVISION } 5 r'art"" RYtC ? o the `pp¢ONS ff -°: "`;;;17- ier cEpprOVF1 >f ng Divrw . ZIY,iro a R ^;`s t:` - i ^n F Jbrn al cc t" eVIP . •...t�2'v...,:�iV;ia1 Wan i... � I fees. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Planning Pivision City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, international Mechanical Code ZONING: SF1200 OCCUPANCY: (No Cha�nQe) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v 8 NON SPRINKLERED 0119002635 LEGAL DESCRIPTION: LOT(S) 69,10,11 AND12, BLOCK 12, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF RECORDED N VOLUME 12 OF PLATS, PAGE(8) 100, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. DRAWING INDEX T0.0 A1.0 42.0 42.1 A22 42.3 TITLE SI -SET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES E1.1 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 2%.0190 Contact: Sharyn Parker E- mail: 5haryn.Parker•kingcounty.gov ARCHITECT: S.M. Stamper Architects PL.L•G. 4000 Pelridge Way SW, Suite 200 Seattle, WA 58106 Ph: 206. 624. 21TI Fax: 206.624.2513 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: ,Jerryssmstemper.com melodyssmstemper.com timasmstemper.com ACOUSTICAL ENGINEER 55A Acoustics 222 Etruria Street, Suite 100 Seattle WA 58105 Ph: 206. 535. 0515 Fax: 206.535.0524 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle, WA 98115 Ph 206. 318. 0565 Fax: 206. 318. 0641 Contact: Dylan Turner E -mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcrstresweat.com REGULATED MATERIALS: P55 Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 58102 Ph: 206. 232. 5635 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: tim ogdenapbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 1200 Easton, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: CMaedasjonespayne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 55121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronnspsm- engineers.com JUN 08 2012 VICINITY MAP (NTS) s.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 r)ELRIIDGE WAY SW SUITE 20C • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2131 3/1/12 .EVRER iiINGTON 0 a_ J Q z 0 z z z 0 U z MPROVEMENTS O W W W co 0 ce z CA AIP NUMBER 3 -53- 0058 -044 z 0 z_ C1} Q J DATE 311/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.21 FUR CRAWL SPACE LOWER FLOOR PLAN 1/4 " =1' -0" SPECIAL NOTES: NOTES: I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PANT. G LAUNDRY ROOM L I V INCA ROOM GENERAL NOTES 1 CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER 51-IALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 .4M EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT POOR OR WINDOW I5 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 P11. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WNDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHNG DETAILS SHEET FOR WINDOW REPLACEMENT. . EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. NSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND /OR MECI -L COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVNG AS REQ'P AND RE- CONSTRUCT SHELVING IN COORDNATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FNISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FNISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. I. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. I. CONTRACTOR 15 TO VERIFY CHAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE 15 EIGHT HOURS. POWER MUST 8E PROVIDED AT RESIDENCE BEFORE &00 AM 4 AFTER 5:00 PM. MAIN FLOOR PLAN 1/4" = 1' - 0" A. WEST ELEVATION 14' -4" 14' -0" L II 'I 1r 11 I,� `I IF TYP. III Ili 011 II I I � I I 1 N L - r-- -: - =r-1 ... r....... r 01, i i i 9' -2" __7 = 1 ` -a _ 14° x ;4 ".EXLST. 4 0 ATTIC ACCESS a 1 PANEL ; I 1 1 III I 1 • r--. I ly I 1 1 1 1 ] LJ 11 11 I� L' c L B. NORTH ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 0 2 DEMOLISH EXISTING DOOR(5), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. ��..// DOOR SCHEDULE. O DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1 /422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. G DEMOLISH EXISTING DOOR(5), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A2.1. FLUSH SOLID CORE NTERIOR WOOD DOOR WITH TRIM PACKAGE BOTH ELEVATIONS, INCLUDE INTERIOR HARDWARE SET. CD BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 3/A22 FOR DETAIL. ® COORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. c:: INSTALL VENT BAFFLE(5) AT EXISTING GABLE END VENT(S) N ATTIC. REF. 4/422 FOR DETAIL. ONSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS. 0 DEMOLISH EXISTING PANEL, USE AS JUNCTION BOX. COORDINATE WITH ELECTRICAL DOCUMENTS. 10 NEW ELECTRICAL SERVICE REQUIRED. INSTALL NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. ATTIC PLAN 1/4" = 1' - 0" C. EAST ELEVATION J REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION LEGEND D. SOUTH ELEVATION 1 E A ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER At A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL CEILING DEMOLITION FOR AttIC PANEL AND WHOLE MOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. •,. ▪ REF. GENERAL NOTE 11 ATTIC INSULATION JUN 08 2012 • INSTALL BATTERY OPERATED SMOKE DETECTORS SC INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2131 3/1/12 0 J z O I— z w z H z 0 U 00 z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 z 0 z_ DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC FLOOR PLANS NOTES A1.0 0810.03.2131 WINDOW TYPES 1. HORIZONTAL XX SLIDER 2. 3. CASEMENT SLIDER/ FIXED/ SLIDER 4. HORIZONTAL SLIDER / FIXED WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A BEDROOM 1 1 4' -7" x 4' -5" STAIN /PAINT SAFETY GLAZING REQUIRED 1/A2.0 B BEDROOM 2 1 4' -10" x 1' -10" STAIN /PAINT CUT DOWN SILL TO 40" AFF. FOR EGRESS (E) SILL HT. 58" 2/A2.0 C OFFICE 1 3' -9" x 1' -9" STAIN /PAINT 1/A2.0 D KITCHEN 1 3' -5" x 1' -11" STAIN /PAINT SAFETY GLAZING REQUIRED 1/A2.0 E KITCHEN 2 2' -3" x 4' -5" STAIN /PAINT 1/A2.0 F KITCHEN 4 5' -1" x 4' -4" STAIN /PAINT 1/A2.0 G LIVING 3 5' -0" x 4' -5" STAIN /PAINT 1/A2.0 H LIVING 3 5' -0" x 4' -5" STAIN /PAINT 1/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. SLOPE I" min. I " min. L END CLOSURE f I HEMMED EDGE J HEAD FLASHING DETAIL TYP. 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF- ADIWIERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE- PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY (E) GIJJ5 (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. OLID WOOD TRIM IUD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) UJALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) UJALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WD. SIDING WINDOW HEAD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING (E) GWB BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY SACKER ROD 4 SEALANT WINDOW NAILING FIN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW JAMB WD JAMS LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT �3/4" 3/4" WD. SILL - STAIN TO MATCH (E) WINDOW SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TTP. SELF- ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" (E) IUD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF- ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. FRE- PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY REMOVE (E) WD. SIDING FOR (E) GUJ5 (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENNG FRAMNG. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PANT MODIFIED SIDING TO MATCH (E) SIDING (E) IUD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING WINDOW HEAD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT ACOUSTICAL WNDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN ----___ TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW JAMB (E) GWB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW SILL SILL HEIGHT 40" AP 3/4" WD. SILL - STAIN TO MATCH (E) SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. (2) 2X SILL PLATE SELF- ADHERING MEMBRANE (E) GWB 1)1-1%1'17 WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION JUN 08 2012 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 1 3/1/12 0810.03.2131 O 0 J z O z z 1— z 0 U 0 z AIP NUMBER MPROVEMENTS 0 w w w 0 z H Z W cn 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2131 DOOR TYPES O ,A FLUSH SCW INTERIOR PULL LITE, W/ SAFETY GLAZING FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ OBSCURE SAFETY GLAZING W/ OBSERVATION PORT c EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING A 2' -8" x 6' -8" STAIN /STAIN HW -1/613 DK -2 LOCK -1 1/A2.1 2 KITCHEN (INTERIOR) g 2' -6" x 6' -8" STAIN /STAIN HW -1/613 DK -3 2/A2.1 3 LIVING C 2' -8" x 6' -8" 1/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. I" min. 1/1" min. HEMMED EDGE J SLOPE L —J END CLOSURE E C.4 HEAD FLASHING DETAIL TYP. 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) UJOOD SIDING FOR INSTALLATION OF NEW DOOR ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING A5 REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE - PRIMED, GALV SWEET METAL FLASHING W/ END CLOSURE UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM 514111 AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER - STRIPPING DOOR PER SCHEDULE 2" MIN. REMOVE (E) W. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO POOR OPENING FRAMNG. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. NSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDNG JOINTS 4 SET NAIL HEADS FLUSH. PANT MODIFIED SIDNG TO MATCH (E) SIDING DOOR HEAD (E) WOOD SIDING CONTINUOUS SEALANT BEHND z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER - STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR JAMB (E) EXTERIOR 514EATHING DOOR SHOE 2" MIN. DOOR SWEEP ALUMNUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR SILL CONTINUOUS SEALANT, TYP. EXISTING FRAMING 5OLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 "= 1' -0" SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATI -ER STRIPPING KERF N CONTINUOUS WEATHER STRIPPING SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION BACKER ROD AND SEALANT SOLID WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING DOOR HEAD CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM INTERIOR DOOR PER SCHEDULE KEW IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL EXISTING FRAMING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM POOR PER SCHEDULE INTERIOR - DOOR DETAIL SET 3 " =1' -0" p1)--1q7 I, /l tr;!E¢ FOR iMPLIANCE ROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION JUN 08 2012 ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 3/1/12 0810.03.2131 i- ce O 0 ce J Q z O 1-- z w 1— z i- z 0 0 0 z AIP NUMBER MPROVEMENTS 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2131 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF- ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE - PRIMED, GALV. SHEET METAL FLASHING W/ FF. END CAPS UNDER SELF- ADI -IERNG MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN 714E FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH: PANT NTERIOR W/ ACOUSTICAL DAMPNG COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. 1 (E) WALL UNDERLAYMENT SELF-ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" C� BLENDING AIR UNIT DETAIL 1 1/2" = 1' - 0" SUSPEND MECH UNIT FROM (E) STRUCTURE R1=: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL EXISTING ROOF (E) ROOF FRAMING INSULATION DAM DETAIL 3 "= 1' -0" EXIST. WALL CONSTR (2) SIMPSON A -34 • EACH SIDE PANEL EXIST. GABLE VENT NEW " GALV 14ARDWARE CLOTH ;" CDX PLYWOOD AT (3) SIDES BLOU• IN CELLULOSE INSULATION WITH A COMBINEI VALUE OF NOT LESS THAN R -3S INSULATION DAM (E) WALL FRAMING 1" OWENS CORNING 1103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD SACK AND SIDE PANEL NOTE: I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. GABLE END VENT BAFFLE DETAIL 1 1 /2" = 1' - 0" rri REVIEWED FOR CODE COMP!. LANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION JUN 08 2012 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DFLRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624 -2973 0810.03.2131 3/1/12 0 0 J z < ww 0 I— E Z w C!) z Q z F J LJ z U 0 Et U < 0 _Z Q z w 0 (1) w MPROVEMENTS AIP NUMBER 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC MISC. DETAILS A2.2 0810.03.2131 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. PLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. .--(E) SHEATHING 12" LAP SILL MEMBRANE FLASHING 2 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA END OF SILL. (E) BLDG. PAPER AT SILL CUT SILL FLASHING E FOLD THROUGH R.O. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MIN " TYP. BUTTERFLY CORNER FLASHING MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 51•IOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. ELEVATION VIEW` -� NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS (7 NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOILN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. L J MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWINCI STEPS). HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RD. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT J4113 FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS N NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. 0 INSTALL 514T. METAL HEAD FLASHING UNDER (E) BLDG PAPER - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1 /5" LEARANCE 4 p..r,: t }' ` "> BETWEEN FL RING AND 1301. EDGE • (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO_ AT HEAD AND JAMBS. MEMBRANE FLASHING AT HEAD ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. O 0 0 6 WINDOW FLASHING INSTALLATION K SCALE: NTS SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING C9 WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/5" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF API-FEARING MEMBRANE FLASHING" TYPICALLY REFEREP TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "-1 AND S" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. bt,iqi REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION JUN 08 2012 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 3/1/12 rX O 0- —J z 0 z w z 1— Z 0 0 0 z MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2131 O O O G C O O 0 0 0 ELEVATION VIEW` -� NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS (7 NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOILN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. L J MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWINCI STEPS). HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RD. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT J4113 FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS N NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. 0 INSTALL 514T. METAL HEAD FLASHING UNDER (E) BLDG PAPER - INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW 1 /5" LEARANCE 4 p..r,: t }' ` "> BETWEEN FL RING AND 1301. EDGE • (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO_ AT HEAD AND JAMBS. MEMBRANE FLASHING AT HEAD ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. O 0 0 6 WINDOW FLASHING INSTALLATION K SCALE: NTS SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING C9 WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE I/4 " -3/5" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF API-FEARING MEMBRANE FLASHING" TYPICALLY REFEREP TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "-1 AND S" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. bt,iqi REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION JUN 08 2012 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 3/1/12 rX O 0- —J z 0 z w z 1— Z 0 0 0 z MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2131 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SRC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEIUNG ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STA11C PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDI11ONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SEATTLE RESIDENTIAL CODE SCREENED OPENING STA11C PRESSURE STA11C PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STA11C PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL 0 ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE �- DIRECTION OF FLOW OR XSx EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y %/////////, EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX ABBR 0 -> 041- DN DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH ® OR ® THERMOSTAT EQUIP ID# O EQUIPMENT LOCATION I NG • 0 D'a MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 4 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STA11C DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <08" WG 8" 8" CEIUNG ALLGRILLE 1, 2, 4 0G -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3 RG -1 25 <08" WG 4" 4" CEIUNG DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2131 913 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. bl� -I�i7 MECHANICAL VENTILATION CALCULATION PER WAC 51 -51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) 45_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1 /2) = 90 CFM S.M. STEMPER ARCHITECTS A Proteadonal Limited Liability Company 4000 DELRIDGE WAY SW STATE 200 • SEATTLE, WA 98108 (200) 624 -2777 • FAX (206) 024 -2973 THE GREENBUSCH GROUP, INC . •a.....) )) 1 9111E 201 SEAM 115 N119 (206) 378 -0009 (206) 376-0641 FAX EXPIRES: 9/08/2012 0810.03.2131 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3- 53- 0058 -044 TUKWILA WASHINGTON DATE 3/1/2012 ISSUED GROUP 21 100% JUN 0 8 2012 KIWI AND APPROVAL REQUIRED PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2131 NO MECHANICAL WORK THIS LEVEL STORAGE FUR CRAWL SPACE LOWER FLOOR MECHANICAL PLAN NORTH SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS RETURN AIR DUCT OUTSIDE AIR DUCT HOLD 'TIGHT TO STRUCTURE USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. ATTIC MOTOR ACCESS FILTERS ACCESS BLENDING UNIT INSTALLATION DETAIL SCALE: NONE SEE m2.0 TYP ALL CEILING GRILLES SHEETMETAL TRANSITION TO GRILLE NECK SIZE MAIN FLOOR MECHANICAL PLAN NORTH 2 SCALE: 1/4" = 1' -0" DUCT PER PLAN 2X BLOCKING FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON 2X BLOCKING WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE r E 4 "0 DN L TO RG -1 1 14' x 24' EXIST. ATTIC ACCESS PANEL 4 "0 4 "0 4 "0 DN TO RG -1 n —J I I 1 LJ I - - - -_� I__� DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE C _J ATTIC MECHANICAL PLAN NORTH FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING SCALE: 1/4" = 1' -0" NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL SCALE: NONE 1. DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK -OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. FLAG NOTES: 1).--197 13V -1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.6.4. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. JUN 08 2012 SEPARATE PERK" AND APPROVAL REQJhRED S.M. STEMPER ARCHITECTS A Prateeeional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (20e) 824 -2777 • TAX (206) 824 -2076 THE GREENBUSCH GROUP, INC 0414114 41111100 ))) 110:5 weir 1 CI SLW ! EIEE c201 =TIE GWA 9e10 (208) 37e -0569 (208) 376 -0641 FAX 1 EXPIRES: 9/08/2012 0810.03.2131 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 3/1/2012 TUKWILA WASHINGTON ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.0 0810.03.2131 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES O PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. ® PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 3® HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW WEATHER HEAD, MAST GUYS AND ANCHORS AT EXISTING LOCATION. PROVIDE NEW ROOF FLASHING. TRIM VEGETATION TO PROVIDE MINIMUM 36" CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. DEMO EXISTING FUSE TYPE PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL 5Ert,-;RoOM NEW PANEL. SEE DETAIL AND PANEL SCHEDULE DEMO EXISTING PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL E,4-1-1-4 1\--TO BV -1 :411 E ..FS. ACCESS PEA r- H K. T0b =N w u 11 I v) RTh O I E:IROO 1 MAIN FLOOR PLAN 1/4" = 1' L /,'NG ROOM (NORTH ELECTRICAL LEGEND WWI_ DESCRIPTION SYM$OL DESCRIPTION G UGH11NG OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. ® BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 111111 �} DAMPER CONNECTION Q' NON -FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD ES' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR El ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. UT THERMOSTAT — - — E CEIUNG MOUNTED FIRE ALARM - VISUAL STROBE UGHT ® UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 1 16 N/A 15 16 N/A REMARKS BV -1 BLENDING UNIT VENTILATOR SWITCHES (ON, TIMER) 120 1 X X 120 X 1,2 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH '411 i 2 EX wi . T C CCES tee_ J L ATTIC PLAN 1/8" = 1' C 1 JUN 08 2012 SEPARATE PERMIT AND itpPROVAL REQUIRED S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■N�INIERS, INO all SOWN N MliR wln. w� 11101111116 OK M..... 7.1Y. — A MM rMI MIS wSOB 0810.03.2131 0 a ce 0 J f'-' Q Z W Z Z 0 U C� Z AIP NUMBER MPROVEMENTS 5 -53 -0058 -044 SEATTLE WASHINGTON DATE MAR 1, 2012 ISSUED 100% CD PROJECT ENGINEER CHI PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2131 PANEL LOCATION: SERVING: RESIDENCE CKT LOAD DESCRIPTION TYPE KVA EXISTING LOAD 3 5 EXISTING LOAD 7 EXISTING LOAD 9 EXISTING LOAD 11 EXISTING LOAD 30/2 2011 13 EXISTING LOAD 15 EXISTING LOAD 17 BLENDING UNIT 19 21 23 LOAD TYPE CONN. LOAD H 20/1 120/240 VOLT, 10,00 C, 1 PHASE, 3 WIRE. 200 AMP with MAIN BKR PHASE NP A A 50/2 40/2 20/1 ! A 20/1 3011 30/1 20/1 B 20/1 20/1 20/1 20/1 COMPUTED LOAD ❑ ISOLATED GROUND BUS ❑ ,RAINTIGHT NEMA -3R ENCLOSURE REMARKS: [] FEED THRU LU ❑ DOUBLE LUGS A PE LOAD DESCRIPTION EXISTING LOAD EXISTING LOAD EXISTING LO PROVISION PROVISION PROVISION A KT 2 4 6 8 10 12 14 16 18 20 TOTAL LOADS KVA 22 24 P N BKR SHUNT TRIP PANEL SKIRTS ❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS A ❑ SURFACE ❑ FLUSH P PROVIDE NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS ROOF PROVIDE NEW SERVICE DROP FROM POLE TO HOUSE BY SCL. ALL FEES PAID BY CONTRACTOR. 2 "C, 3#3/0 CU METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PANEL MP 200A 120/240 1 -PH, 3W 2 "C, 3#3/0 CU.& GND PROVIDE METER BASE PER SCL STANDARD #DU13- 4 /NMT -30 E--- r-PROVIDE #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND ■ PROVIDE NEW NEMA -3R S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONN OT TO NEW BREAKERS. PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS PRIOR TO BID. NEW SERVICE DETAIL 1ct SCALE:NONE JUN 08 2012 S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■N•INIU11e. INC NM SOW %M VIM NMI IN UMW 10224011 'MI✓wO- MM IM MM 111 412 S 0810.03.2131 O a Z 0 ce z w z z 0 0 0 Z MPROVEMENTS 0 w 2 cn w w 0 z Li 0 SEATTLE WASHINGTON FLOOR PLANS NOTES E1.1 0810.03.2131