HomeMy WebLinkAboutPermit D12-198 - HALBERT RESIDENCE - UPGRADESHALBERT RESIDENCE
4030 S 117 PL
D12-198
City Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 7340600106
Address: 4030 S 117 PL TUKW
Suite No:
Project Name: HALBERT RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D12 -198
Issue Date: 07/27/2012
Permit Expires On: 01/23/2013
Owner:
Name: HALBERT JACK E
Address: 4030 S 117TH PL , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: S K M CONSTRUCTION INC
Address: 14415 SE 143 PL , RENTON, WA 98059
Contractor License No: SKMCOI *052L3
Lender:
Name:
Address:
Phone: 206 - 296 -7437
Phone: 425 235 -5569
Expiration Date: 12/30/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $52,491.00 Fees Collected: $1,635.20
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -198 Printed: 07 -27 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit
Signature:
2 J2�C 71� 1 l�rL��
Date: t(ij ice,
Print Name: av
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread
index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed
spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply
to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or
floor finish.
doc: IBC -7/10
D12 -198 Printed: 07 -27 -2012
6: All construction shall be done in confo a with the approved plans and the require of the International
Building Code or International Residential, International Mechanical Code, Washingate Energy Code.
7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D12 -198 Printed: 07 -27 -2012
CITY OF TUKWILA)
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.atulcwila.iva.us
Building PermiNo.
Mechanical Permit No. M
Plumbing/Gas Permit No.
Public Works Permit No.
Project No. _I „)_ 0 te
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 4030 S. 117th PI.
Tenant Name:
Jack E. Halbert
Property Owners Name: Jack E. Halbert
Mailing Address: 4030 S. 117th P1.
King Co Assessor's Tax No.: 7340600106
Suite Number: Floor:
New Tenant: ❑ Yes
Tukwila
WA
City
State
..No
98168
Zip
CONTACT PERSON— who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
City
Day Telephone:
E -Mail Address: Fax Number:
Expiration Date:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA
98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\Applications\Fotms- Applications On Ltne\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 1 of 6
BUILDING PERMIT INFO
Valuation of Project (contractor's bid price): $ 52,491 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
I.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Will there be a change in use?
Handicap:
❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
. ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications \Forms - Applications On Line Applications \I -2009 - Permit Apphcation.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
lat Floor
1,560
rd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Will there be a change in use?
Handicap:
❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
. ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications \Forms - Applications On Line Applications \I -2009 - Permit Apphcation.doc
Revised: 1 -2009
bh
Page 2 of 6
MECHANICAL PERMIT INFd f1ATION - 206 - 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ 1 O — '0
Scope of Work (please provide detailed information): ,
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement .Alt ❑
Fuel Type: Electric ❑ Gas .... Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
I
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig /Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm /Ind
H:WpplicationsWotms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 4 of 6
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑... Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certific
Septic System:
❑ On -site Septic System — on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
❑ .. Highline
❑...Valley View ❑ .. Renton
El... Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Submitted with Application (m
boxes which apply):
❑ ...Civil Plans (Maximum Pape • ize — 22" x 34 ")
❑ ...Technical Information Report ( Drainage) ❑ .. Geotechnical Report
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than - ours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction /Excavation/Fill - Right -of -way ❑
Non Right -of -way
❑ ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑...Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ... Hold Harmless — (ROW)
❑ . ght -of -way Use - Profit for less than 72 hours
ight -of -way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ ...Sanitary Side Sewer ❑ .. Abando
❑ ...Cap or Remove Utilities ❑ .. Curb t
❑ ...Frontage Improvements ❑ .. Pay ent Cut
❑ ...Traffic Control ❑ .. :.ped Fire Line
❑ ...Backflow Prevention - Fire Protection
eptic
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size.. WO #
❑ ...Water Only Meter Size WO # ❑...De. Water Meter Size
❑ ...Sewer Main Extension blic ❑ Private ❑
❑ ...Water Main Extension .Public ❑ Private ❑
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
FINANCE INFORMATION
Fire Line Size at Property Line
❑ ...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Number of Public Fire Hydrant(s)
❑ ...Sewage Treatment
Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
H:\Appltcatrons ■Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 3 of 6
PERMIT APPLICATION NOTES Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAM TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHO
of /, 1
4,,
Signature:
Print Name: Timothy
enlason,
Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Date: (/e120 (
Day Telephone: (206) 624 -2777
Seattle WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPIN•ERMIT INFORMATION 206 -43
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please pro detailed information):
Building Use (per Int'I Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outs being i talled and the quantity below:
Fixture Type:
Qty
Fixture Type:
1 ty
ixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
ood -waste grinder,
, mercial
Floor Drain
Shower, single head trap
Lavatory
W . fountain
Receptor, indirect waste
Sinks
Urinals
Water et
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or v=
Industrial w. - .treatment
interceptor, in 4 ing trap
and vent, except kitchen
type grease interces • s
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alterati ' of
water piping an s r water
treatment equi ent
Repair or alteration o
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow pr, ective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
stem on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:Wpplications\Fomts- Applications On-Line \2009 Applications \I -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
Cif of Tukwila, •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R12 -01839
Initials: WER
Payment Date: 06/11/2012
User ID: 1655 Total Payment: 9,571.97
Payee: PAMELA KUEHL
SET ID: 0611 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D12 -196 1,067.51
D12 -197 993.76
•Di2 -198 1, 635..20___)
D12 -199 1,856.13
D12 -200
D12 -201
D12 -202
M12 -089
M12 -090
M12 -091
M12 -092
M12 -093
M12 -094
M12 -095
TOTAL:
905.73
779.67
1,141.27
167.70
167.70
177.10
177.10
167.70
167.70
167.70
1,067.51
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 9,571.97
TOTAL: 9,571.97
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
MECHANICAL - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.322.102.00.0
000.345.830
640.237.114
TOTAL:
5,059.25
1,192.70
3,288.52
31.50
9,571.97
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 r. 1(206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
YN L, %4RS 1Z..�
Address:
1-10 76'0 � U) et—
Type of Inspection:
j— INJA1,r
Date Called:
K7'1 G
Special Instructions:
o'
Date Wanted:
ICS -S -(Z_
(.m.
p:m:
Requester:
Phone No:
-0G -2(% - cC13Cj
Approved per applicable codes. El Corrections required prior to approval. /g
COMMENTS:
Inspector:
kJ)
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Date: t !� �� `
•
ttliN1 GUM COP)
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -198
PROJECT NAME: HALBERT RESIDENCE
SITE ADDRESS: 4030 S 117 PL
X Original Plan Submittal
Response to Correction Letter #
DATE: 06 -08 -12
Response to Incomplete Letter # ....
Revision # After Permit Issued
DEPAR MENTS:I�
C. lit()"`
1)uilding Division
Public Works ❑
Fire Prevention
Structural
Planning Division
Permit Coordinator
so
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 06 -12 -12
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route NJ Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
n
Approved with Conditions
DUE DATE: 07 -10 -12
Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople P ter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name 5 K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pl License No. SKMCOI'052L3
Suite /Apt. License Type Construction Contractor
City Renton Effective Date 6/23/1995
State WA Expiration Date 12/30/2013
Zip 98059 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMC0 093L6
5 K M
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI'976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NATL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.0004/26
/2010
4
DEVELOPERS SURETY
Et INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.00
12/05/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
15
Co es River Ins
00049593
08/21/2011
08/21/2012
$1,000,000.00
08/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.0008
/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.00
01/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.0001
/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
8
AMERICAN
STATES INS CO
01CD87273810
12/30/2005
12/30/2006
$1,000,000.0012
/06/2005
https: // fortress .wa.gov /lni /bbip /Print.aspx
07/27/2012
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO711C12 BID PACKAGE M -30
3 -53- 0058 -044
SCOPE OF WORK
RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL VENTILATION. L BUT NOT LIMITED INCLUDES ALL INFORMATION N THE DRAWINGS AND
A P P L I CA B L E
YES NO
1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITI1 NEW VINYL - FRAMED ACOUSTICAL WINDOWS.
X
2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIRE`1ENTS.
X
3. INFILL OF EXISTING OPENINGS.
X
4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS.
X
1. INSTALLATION OF SECONDARY SKYLIGHTS.
X
8. INSTALLATION OF PET DOORS.
X
9. INSTALLATION OF FIREPLACE FRESH AIR VENT.
X
10. INSTALLATION OF CHIMNEY CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, P.RNACE MODIFICATION AND
ASSOCIATED DUCTING.
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION.
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARCHITECTURAL MODIFICATIONS.
X
18. INSt4LLA1ION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL SERVICE.
X
20. KNOB AND TUBE WIRING.
X
Penna. No.
PI,.. r^,,►cr approval is subject to errors and omissions.
• ytruction documents does not authorize
1 f: or .:1 any adopted code or ordinance. Receipt
o: ;��;rt�v�v; Ena vapy and conditions is acknowledged:
L � � it ess)
City Of Tukwila
BUILDING DIVISION
By Q
Date:
REVISIONS
r'!r chn^p s sht t hr; rnGc'e to the scope ;•,:•� -'; 1�•i';;' '= prior approval of
w . .. 1.tu :°wing Division.
rzqu re a new plan
submittal
it\ •Z p , a 1 tg awtrie ad-Ilona, plan review fees.
,S,7 ,.,R., s J2 PERMIT
{t .� FD
2 :cchan :cal
LeEi c ricai
iUrbing
Piping
T ukt4Ia
I:`1VISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
Vitk
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Planning Division
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
1340600106
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
v B NON SPRINKLERED
LEGAL DESCRIPTION:
RIVERSIDE INTERURBAN TR5 PARCEL D OF KC SHORT PLAT 511129 REC AF "1112090189 SD PLAT DAF N 90 FT OF TR 5
RIVERSIDE N1ERURBAN TRS
DRAWING INDEX
T0.0
41.0
A2.0
A2.1
A22
42.3
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, AEBREV, GENERAL NOTES 4 DM INDEX
MW MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Shan") Parker
E- mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stemper Architects P. ..C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E-mail: jerryesmstemper.com
melodyesmstemper.com
timesmstemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 95109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Dylan Turner
E -mail: DylanTegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIALS:
P55 Engineering and Environmental
2511 Eastlake Ave. E, Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162. 4180
Contact: Tim Ogden
E -mail: trm ogdenepbsenvcom
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washinnggton St. "200
Boston, MA 02114
Contact: Tim Fenlason,
Cynthia Maeda
E -mail: CMaedasjonespaynecom
STRUCTURAL ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 98121
Ph: 206. 622. 4580
Fax: 206.622.0422
Contact: Ron Martinson
E -mail: ronmepsm- engineers.com
ECEIVED
JUN 08 2012
PERMIT CENTER
VICINITY MAP (NTS)
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.2132
3/1/12
0
Ct
d
-J
Z
O
H
z
w
z
z
0
0
v
z
MPROVEMENTS
0
w
w
w
0
z
..J
W
LLI
AIP NUMBER
3 -53- 0058 -044
TUKWILA WASHINGTON
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
PROJECT
INFORMATION,
DRAWING
INDEX,
DIRECTORY
T0.0
0810.03.2132
CLOSET
BATH I
24" x 48" EXIST.
BEDROOM ATTIC ACCESS
PANEL
CD"
KITCHEN
DINING
ROOM
BEDROOM
2
SPECIAL NOTES:
NOTE:
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
I
BEDROOM
3
LIVING
ROOM
NO WORK IN
BASEMENT
MAIN FLOOR PLAN
1/4" = 1' - 0"
LOWER LEVEL FLOOR PLAN
1/8" = 1' - 0"
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM.
6. PO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
1 ADD SOLID WOOD BLOCKING AT WINDOWS.
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON NE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
II. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRICT
51-ELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 5O AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT NE
PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
I. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS 51-IALL BE CONCEALED.
17. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AID FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
I. CONTRACTOR I5 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
20. MAXIMUI1 POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P1" .
A. SOUTH ELEVATION
DECK
J
54'-1"
L_
. . r = —. —.— -
1I
Ali - - - -7- - - - LJ- - - •
/
/
/
/
/
n
/
/
/
/
/
/
/
\
II 11
11
11
IL
I1
1 - - - - -- 1 r
I
. .0 . . . . A�
11
I. I• • -i - - -
1 I 1 L. - ..c. -•
I 1 24" x 4S" 1 =kr5T. ATTIC- I J r7/. . . . . .
L - - ACCESS'PANEL is
I-I 11 .1 1
I I- I- I I 1
1.1 - 1 11 I I /
I I- I- I H i ,
I.1 11 it / /
11 1.1L., I / Fl
-F -- . . . . . . . . . / f . . . . . . . • . . . . . .
1-1 /
r—II III- /
RJR
ri
ri
II II
B. WEST ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE.
2 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF.
DOOR SCHEDULE.
3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
0 INSTALL NEW SECONDARY SLIDING GLASS DOOR REF. DOOR SCHEDULE.
': INSTALL ROOF MOUNTED BAFFLE(S) AT EXISTING KITCHEN EXHAUST. REF. 4/A22 FOR DETAIL.
OINSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
c3/16" = 1' - 0"
Fib
_ J
. A . . .
THERE ARE 2 CEILINGS IN THIS RESIDENCE.
INSTALL INSULATION ON TOP ATTIC SPACE
ONLY.
C. NORTH ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
D. EAST ELEVATION
LEGEND
r
ACOUSTICAL WINDOW
REFER TO WINDOW SCHEDULE
ACOUSTICAL DOOR
REFER TO DOOR SCHEDULE
EXTERIOR STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
-- DOOR REFER TO DOOR SCHEDULE
1131
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
1111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATHER TEXTURED CEILING OVER AT A
MIN. OF 24" FROM EDGE OF PATCHING.
MATCH (E) TEXTURE AND PAINT
•
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
Y: r•'.; ..: ... -. j REF. MECH. i ELECT
REF- GENERAL NOTE RECEIVED
JUN 0 8 2012
ATTIC INSULATION PERMIT CENTER
(:)/ INSTALL BATTERY OPERATED SMOKE
DETECTORS
SG
INSTALL BATTERY OPERATED SMOKE /
CARBON MONOXIDE DETECTORS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624-2973
REG1S1E+ED
1107 !'
:,Coii .141 TEMP
STATE C'- 1' 3HINCTOv
3/1/12
081 0.03.2132
0
a_
attt
z
O
t-
<
z
W
z
z
0
0
00
z
AIP NUMBER
MPROVEMENTS
3 -53- 0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
FLOOR
PLANS
NOTES
A1.0
0810.03.2132
WINDOW TYPES
HORIZONTAL
XX SLIDER
2.
DOUBLE -HUNG
3.
CASEMENT
4.
FIXED OVER
HORIZONTAL XX
SLIDER
WINDOW SCHEDULE
WINDOW
NO
ROOM
LOCATION
VIAND.
TYPE
SIZE
WxH
TRIM FINISH
INT. /EXT.
REMARKS
DETAIL SET
A
KITCHEN
1
2' -5" x 3' -0"
STAIN /PAINT
1/A2.0
B
KITCHEN
1
2' -5" x 3' -0"
STAIN /PAINT
1 /A2.0
C
KITCHEN
2
2' -10" x 3' -2"
STAIN /PAINT
1/A2.0
D
BEDROOM 1
2
3' -4" x 5' -9"
STAIN /PAINT
1/A2.0
E
BEDROOM 2 (CLOSET)
3
2' -4" x 2' -4"
STAIN /PAINT
1 /A2.0
F
BEDROOM 2
2
3' -4" x 5' -5"
STAIN /PAINT
1 /A2.0
G
BEDROOM 3
2
3' -4" x 5' -5"
STAIN /PAINT
1 /A2.0
H
LIVING
4
5' -0" x 5' -0"
STAIN /PAINT
1/A2.0
I
LIVING
4
4' -2" x 5' -0"
STAIN /PAINT
1/A2.0
J
DINING
4
7' -6 1/2" x 4' -6"
STAIN /PAINT
1/A2.0
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND NSTALL SELF - ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDNG
TO MATCH (E) SIDING.
PRE- PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF- ADHERNG MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMNED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
(E) GUS
(E) WALL UNPERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
CONTINUOUS
SEALANT, TYP.
REMOVE (E) WD. SIDING FOR
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT AND INSTALL
WINDOW / NAILING FLANGE OVER SELF
ADHERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
WINDOW HEAD
LID WOOD TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
(E) GWB
CONTNUOUS
SEALANT, TYP.
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
I III
WINDOW JAMB
SOLID WOOD TRIM
WD JAMB LINING
SEALANT
SHIM ,48 NECESSARY
FILL GAP W/ BATT
NSULATION
BACKER ROD 4
SEALANT
3/4"
3/4" WD. SILL - STAIN TO
MATCH (E)
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMNED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDNG AS REQ'D. MANTAIN
(E) COURSING. PANT MODIFIED SIDNG
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
0
WINDOW SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
SELF- ADHERING
MEMBRANE
(E) MUD
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
1
SLOPE
1" min.
min.
T
HEMMED EDGE —1
LEND CLOSURE
E
HEAD FLASHING DETAIL TYP.
3" = 1' - 0"
p1)-- 198
REVIEWED FOR
CODE COMPLIANCE
4 APPROVED
'JUN 2 1. 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
JUN 08 2012
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGI$TEI E:C
' 'rI Ii "r
3/1/12
0810.03.2132
0
a_
Q J
z
0
z
w
z
z
0
U
z
MPROVEMENTS
0
w
w
w
0
z
U_
U
w
0
AIP NUMBER
3 -53- 0058 -044
Z
0
C9
z
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2132
DOOR TYPES
FLUSH SCW
HALF -LITE W/ MUNTINS,
SAFETY GLAZING
W/ 2 PANELS
5
3 -PANEL SECONDARY
SLIDING GLASS DOOR
W/ SAFETY GLAZING
G
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR NO
ROOM
LOCATION
DOOR
TYPE
SIZE
WxH
FINISH INT. /EXT.
HARDWARE
SET / FINISH
KNOB /LEVER
SET
LOCK SET
DETAIL SET
1
LIVING
A
3' -0" x 6' -8"
STAIN /STAIN
HW -1/716
DK -4
LOCK -1
1/A2.1
2
KITCHEN
B
8' -10" x 6' -8"
2/A2.1
3
LAUNDRY
C
3' -0" x 6' -8"
1/A2.1
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT
ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT
CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS
SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR / EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
1
1"min.
HEMMED EDGE
1
L�SLOPE
-
_J
LEND CLOSURE
HEAD FLASHING DETAIL TYP.
3 " =1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF - ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW DOOR ASSEMBLY
AND TRIM. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAN (E)
COURSING. PAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE- PRIMED, GALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF- ADHERNG MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
(E) EXTERIOR SHEATHING
CONTNUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
REMOVE (E) WD. SIDING FOR INSTALLATION
OF NEW DOOR TRIMS AND REATTACHMENT
OF (E) SIDNG TO DOOR OPENNG FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE PENETRATION
FLASHNG. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SIDING TO
MATCH (E) SIDING
(E) WOOD SIDING
DOOR HEAD
CONTINUOUS SEALANT BEHIND
Z SAR FRAME
STORM DOOR PER SCHEDULE
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATI.4ER- STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
Oa AIM
ripz
"" MN.
DOOR JAMB
DOOR SILL
(E) EXTERIOR 51-EATHING
CONTINUOUS
SEALANT, TYP.
EXISTING FRAMING
SOLID WOOD TRIM
SHIM AS NECESSARY
R=ILL GAP W/ BAT1
NSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3" = 1' - 0"
(E) LUP. SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING 1U/ END CLOSURE UNDER
SELF - ADHERING MEMBRANE. COLOR TO
BE SELECTED 114 THE FIELD
SELF - ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE IS VISIBLE BELOW
FLASHING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
NSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PANT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) BLDG. PAPER
BACKER ROD AND SEALANT
SELF- ADHEARNNC MEMBRANE
PLYWOOD
DOOR HEAD
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF - ADHERING MEMBRANE
REMOVE (E) WOOL SIDING AND
REPLACE AS REQ'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SELF - ADHERING
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLASHING. PAINT
MODIFIED SIDING TO MATCH (E)
SIDING. TYP. AT HEAD AND
JAMBS
SOLID WOOD LINING. STAIN/
PAINT TO MATCH (E) TRIM.
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. PANT COLOR t0 BE
SELECTED IN THE FIELD
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCH (E) TRIM
SELF- ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
WD. TRIM BEYOND
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS.
SEALANT
(E) FLOOR/ DECK FRAMING
i" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
(E) BEVELED WD. SIDNG
(E) EXTERIOR SHEATHING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOOR FRAME
SOLID WOOD LNING. STAIN/
PAINT TO MATCH (E) TRIM.
(E) PRIMARY SLIDING
GLASS DOOR
DOOR SILL
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WO. FLOOR FRAMING
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
t
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
JUN 08 2012
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELI2IDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
kE I$1 EK ED
.ACTT E,+ TEN/
STATE k!- t' :.)HIN(;T?IW
081 0.03.2132
3/1/12
0
J
Z
0
Z
w
H
z
0
z
0
U
Z
MPROVEMENTS
w
w
w
LeO
z
I--
w
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.2132
(E) GWB
CARERILLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF - ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TIP AT DEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. PAINT MODIFIED SIDING 70
MATCH (E) SIDING.
PRE- PRIMED, GALV. SHEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF - ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. PAINT COLOR t0
BE SELECTED IN THE FIELD
PANT VENTILATION FIXTURE,
COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PANT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
2X BLOCKING
AIR INTAKE DETAIL AT EXTERIOR
3" = -0
DUCT I
CHASE
ANCHOR CEILING NAILER
TO (E) RESILIENT
CHANNEL ONLY. PO NOT
ANCHOR TO JOIST
WHERE WIDTH OF SOFFIT
EXCEEDS MO, INSTALL 2X4
STUDS * 16" OTC.
J -METAL EDGE AND
CAULK JOINT
1-
t
V
SOFFIT DETAIL
DEMOLISH (E) GWB
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D t0 ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL I3E CUT RILL SIZE
OF SOFFIT AREA, TYPICAL
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
2x2 CONT. NAILER
5/8" GWB- PANT t0 MATCH (E) TEXTURE 4
COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE W/ ADJ. ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL
(E) WD FRAME WALL ASSEMBLY
3 "= 1' -0"
EXISTING ROOF
(E) ROOF FRAMING
INSULATION DAM DETAIL
3" = 1' - 0"
BLOWN IN CELLULOSE
INSULATION WITH A COMBINED
VALUE OF NOT LESS THAN
R -38
INSULATION DAM
(E) WALL FRAMING
/ PREMANUFAC RED ROOF
BAFFLE AN- MODEL
634)-
EXISTIN DUCTWORK
SEAL 411 NAILS WITH ROOF
arENT
/ SEAL SHINGLES TO ROOF
CAP ON TOP AND SIDES
NOTE=
1. PREMANUFACTURED ROOF BAFFLE. INSTALL PER
MANUFACTURE'S INSTRUCTIONS.
KITCHEN EXHAUST BAFFLE DETAIL
1 1/2" = 1' - 0"
b1)--1 'I 8
REVIEWED FOR
CODE COMPLIANCE
APPROVED
'JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
JUN 08 2012
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELEIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
RE(y1$TE ED
:;,H11 L(;1
0810.03.2132
3/1/12
0
a.
J z
W 0
0 W 0
z
Z W 0)
iw- Z Q
Z � J
Z U I -
D < rt
J
Z
f--
Z
W
0
W
MPROVEMENTS
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
MISC.
DETAILS
A2.2
0810.03.2132
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 2 -1/2"
OVER (E) BLDG.
PAPER AT SILL
EXTEND 1 3" BEYOND
RO. AT EA. END OF
SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
11" MIN
MEMBRANE FLASHING AT SILL
zo
I 5" di.
BUTTEffLY LOFTIER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE.
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE N SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
Q
D
O
O
O
O
O
O
\\\,.
\\\NO
O O O
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4 WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
pIAGRAMATI CALL Y.
(E) SIDING
NOT SHOWN
FOR CLARITY.
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
WHERE RE l !RED, TRIM
(E) BLDG APER AT
HEAD TO - . PARE
FOR NST LATION OF
HEAD FL ING AND
WNDOW TR
(FOLLOW! ' STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING {
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL 514EATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SWOON FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
L
INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
C5
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER
MEMBRANE FLASHING AT JAMB
SCALE: NTS
TRIMMED EDGE
OF (E) SIDING,
SHOWN
D IAGRAMAT ICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D
(E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
14A5 BEEN INSTALLED.
ALLOW 1/8" CLEARANCE
BETWEEN FL4514NG AN)
8OT. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
INSTALL HEAD
FLANGE FLASHING
OVER WNDOW
NAILING FLANGE
AND FLASHING.
MEMBRANE FLASHING AT HEAD
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.D. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
6
WINDOW FLASHING INSTALLATION
SCALE: NTS
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF
ADHEARNG MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
NSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO 51-EET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS.
ici
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
JUN 08 2012
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
• 'TEi3ED
3/1/12
0810.03.2132
0
a
J
Z
0
z
w
z
z
0
U
0
Z
AIP NUMBER
MPROVEMENTS
0
w
2
w
w
0)
0
z
J
w
w
3 -53 -0058 -044
z
0
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2132
\\\
WOOD TRIM INSTALLATION
SHEET METAL HEAD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4 " -3/8" GAP
BETWEEN WNDOW TRIM
AND WINDOW FRAME.
INSTALL CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF
ADHEARNG MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5 AND 6" REFER TO MEMBRANE
NSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "1 AND 8" REFER TO 51-EET METAL HEAD
FLASHING.
5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK
JOINTS.
ici
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 1 2012
City of Tukwila
BUILDING DIVISION
RECEIVED
JUN 08 2012
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
• 'TEi3ED
3/1/12
0810.03.2132
0
a
J
Z
0
z
w
z
z
0
U
0
Z
AIP NUMBER
MPROVEMENTS
0
w
2
w
w
0)
0
z
J
w
w
3 -53 -0058 -044
z
0
DATE
3/1/12
ISSUED BP M -30
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &DC
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2132
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SRC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SEATTLE RESIDENTIAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
AC>
OR XX
0
X/Y
it / / / / / / / //,
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
5--
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL ABBR
XXX
+ f +
UP
VD
RA /EA
RG
SA
SA
-+•�- •r I- RA /EA
SD
0-
0 0-
EQUIP 1410 R
x
EA
MOD
NG NG
0
•
da
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
PROVIDED
UNDER DIVISION
FURNISHED /MOUNTED
UNDER DIVISION
1MRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
430
<.08 "WG
8 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
150
430
<.08 "WG
8 "0
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2132
3290
3
150 CFM
150 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE 'NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
199
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -51, SECTION M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE M1508.2)
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 112.
QF = 75 / (1 X 1 /2) = 150 CFM
RECEIVED
JUN 08 2012
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.M. STEMPER
ARCHITECTS
A Processional Limitad Liability Company
4000 DELRIDGE WAY SW
SUM 200 • SEATTLE! WA 98108
(866) 684 -8777 • FAX (206) 624 -8973
THE GREENBUSCH GROUP, INC
M1010 LADED t 1t17WMAL Et1 WA 011 N0
1100 wESr SWEET SIIIIE sot sFanF. NI1 ee11e
(206) 378 -0660 (206) 376 -0e41 FAX
EXPIRES: 9/08/2012
0810.03.2132
TIONAL AIRPORT
Z
ce
W
H
Z
O
V
0
Z
MPROVEMENTS
>-
w
w
w
O
z
1-
u_
U
J
Z
W
Lu
AIP NUMBER
3 -53- 0058 -044
DATE
3/1/2012
ISSUED GROUP 21 100%
TUKWILA WASHINGTON
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.2132
CLOSET
(E)EG
BATH 1
24' x 48' EXIST
BEDROOM ATTIC ACCESS
PANEL
CLOSET
KITCHEN
DINING
ROOM
BEDROOM
2
u
BEDROOM
3
CLOSET
LIVING
ROOM
MAIN FLOOR MECHANICAL PLAN
1 SCALE: 1/4" = 1' -0"
NO MECHANICAL
WORK THIS SPACE
LOWER FLOOR MECHANICAL PLAN
LOWER FLOOR MECHANICAL PLAN
SCALE: 1/4" = t-0" NORTH
r
SEE
n
L_
�r
U
n
E - --
LJ
WC -1
150
n
—
E
8"
CHASE, REFER TO
ARCHITECTURAL
1
_J L]
TYP
L
11\
1 1 1
7 CI I - - - -_J L
FULL CEILING SOFFIT,
MAXIMIMUM 12" DEEP,
REFER TO
ARCHITECTURAL
�r-
_
r
J L
L
r
LJ
J
DRAWING NOTES:
ATTIC MECHANICAL PLAN
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51,
SECTION M1508.5.4
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY
THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -51, SECTION
M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE
CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING
OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING
WITH PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK -OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR
UNIT SYSTEMS WITH NEW FILTERS.
REUSE (E)
MIXING BOX
ROOF
(E)SUPPLY
CEILING
VOLUME DAMPER FOR
RETURN DUCT, FIELD
VERIFY SIZE PRIOR TO
ORDERING
MOD, INTERLOCK
TO FURNACE
FURNACE
c9
(E)RETURN
CONTRACTOR TO
MODIFY RETURN
DUCTWORK TO
INSTALL DAMPER AND
OSA CONNECTION
POC
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
NORTH
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT
THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC
51 -51, SECTION M1508.5.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET
OF FURNACE RETURN INLET PER WAC 51 -51, SECTION M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE FURNACE RETURN AIR
DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN
AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY
RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN
THIS LOCATION, IT MAY BE REUSED.
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
DUCT PER PLAN
CAULK
2X BLOCKING
FOAM BACKER
ROD
WALL CAP OR
SIDEWALL GRILLE
SLEEVE AND
ESCUTCHEON
2X BLOCKING
WALL
1
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
RECEIVED
JUN 0 8 2012
PERMIT CENTER
SCALE: NONE
bv"-Icie
SEPARATE
PERMIT'AND
APPROVAL
REQUIRED
S.M. STEMPER
ARCHITECTS
A Psoreeelonal Limited Liability Company
4000 DELRIDGE WAY SW
BUTTS 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624-2272
THE GREENBUSCH GROUP, INC
reeee....■■■
100E weal' ,10310 6111EE16UIE 201 52121LE, woii
(206) 376 - 0669 (206) 376 -0641 FAX
EXPIRES: 9/06/2012
0810.03.2132
TIONAL AIRPORT
KING COUNTY INTERN
v♦
w
w
0
2
0
w
w
w
0)
O
z
�C
W
C
w
AIP NUMBER
3- 53- 0058 -044
DATE
3/1/2012
ISSUED GROUP 21 100%
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
TUKWILA WASHINGTON
M2.0
0810.03.2132
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOU11ON OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
BASEMENT PLAN
1/4" = 1'
NORTH
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
G
LIGHTING OR POWER PANEL
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
m
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
111111
15
4
DAMPER CONNECTION
Q'
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
Jl
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
1
BRANCH CIRCUIT HOME RUN
ei
SMOKE DETECTOR
X
EJ
ELECTRICAL METER
X
TIMER OPERATED SWITCH
-
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
Q
THERMOSTAT
— - —
4ille
CEILING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT
0
UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR
1" IECf- IANICAL / ELECTRICAL COORD INAT ION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
CLOSET
15,4TN 1
KITCHEN
24" x 4S" EXIST.
f�EDRODM ATTIC ACCESS
PANEL
CLOSET
t0 RRJA E
DAMPER
H
DINING
ROOM
BEDROOM
2
E3E ®ROOM
3
LIVINC7
ROOM
CLOSET
I�1
MAIN FLOOR PLAN
1/4" = 1'
D
a - 198
RECEIVED
JUN 0 8 2012
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
■NOIMillie. INO
0810.03.2132
H
0
a
J
z
0
z
oc
w
z
0
0
0
z
MPROVEMENTS
0
w
2
w
w
0
z
LL
0
ce
Z
w
♦♦0
vJ
w
ce
AIP NUMBER
5- 53- 0058 -044
DATE
MAR 1, 2012
ISSUED
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.2132