Loading...
HomeMy WebLinkAboutPermit D12-198 - HALBERT RESIDENCE - UPGRADESHALBERT RESIDENCE 4030 S 117 PL D12-198 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7340600106 Address: 4030 S 117 PL TUKW Suite No: Project Name: HALBERT RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -198 Issue Date: 07/27/2012 Permit Expires On: 01/23/2013 Owner: Name: HALBERT JACK E Address: 4030 S 117TH PL , TUKWILA WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI *052L3 Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 425 235 -5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $52,491.00 Fees Collected: $1,635.20 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -198 Printed: 07 -27 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit Signature: 2 J2�C 71� 1 l�rL�� Date: t(ij ice, Print Name: av This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. doc: IBC -7/10 D12 -198 Printed: 07 -27 -2012 6: All construction shall be done in confo a with the approved plans and the require of the International Building Code or International Residential, International Mechanical Code, Washingate Energy Code. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D12 -198 Printed: 07 -27 -2012 CITY OF TUKWILA) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.atulcwila.iva.us Building PermiNo. Mechanical Permit No. M Plumbing/Gas Permit No. Public Works Permit No. Project No. _I „)_ 0 te (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 4030 S. 117th PI. Tenant Name: Jack E. Halbert Property Owners Name: Jack E. Halbert Mailing Address: 4030 S. 117th P1. King Co Assessor's Tax No.: 7340600106 Suite Number: Floor: New Tenant: ❑ Yes Tukwila WA City State ..No 98168 Zip CONTACT PERSON— who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Contact Person: City Day Telephone: E -Mail Address: Fax Number: Expiration Date: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications\Fotms- Applications On Ltne\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 1 of 6 BUILDING PERMIT INFO Valuation of Project (contractor's bid price): $ 52,491 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes I.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? Handicap: ❑ Yes m No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: . ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line Applications \I -2009 - Permit Apphcation.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 1,560 rd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? Handicap: ❑ Yes m No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: . ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line Applications \I -2009 - Permit Apphcation.doc Revised: 1 -2009 bh Page 2 of 6 MECHANICAL PERMIT INFd f1ATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 1 O — '0 Scope of Work (please provide detailed information): , Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .Alt ❑ Fuel Type: Electric ❑ Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System I Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind H:WpplicationsWotms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 4 of 6 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certific Septic System: ❑ On -site Septic System — on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ .. Highline ❑...Valley View ❑ .. Renton El... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Submitted with Application (m boxes which apply): ❑ ...Civil Plans (Maximum Pape • ize — 22" x 34 ") ❑ ...Technical Information Report ( Drainage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than - ours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction /Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ . ght -of -way Use - Profit for less than 72 hours ight -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abando ❑ ...Cap or Remove Utilities ❑ .. Curb t ❑ ...Frontage Improvements ❑ .. Pay ent Cut ❑ ...Traffic Control ❑ .. :.ped Fire Line ❑ ...Backflow Prevention - Fire Protection eptic Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # ❑...De. Water Meter Size ❑ ...Sewer Main Extension blic ❑ Private ❑ ❑ ...Water Main Extension .Public ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Appltcatrons ■Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 3 of 6 PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAM TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO of /, 1 4,, Signature: Print Name: Timothy enlason, Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Date: (/e120 ( Day Telephone: (206) 624 -2777 Seattle WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN•ERMIT INFORMATION 206 -43 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please pro detailed information): Building Use (per Int'I Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outs being i talled and the quantity below: Fixture Type: Qty Fixture Type: 1 ty ixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) ood -waste grinder, , mercial Floor Drain Shower, single head trap Lavatory W . fountain Receptor, indirect waste Sinks Urinals Water et Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or v= Industrial w. - .treatment interceptor, in 4 ing trap and vent, except kitchen type grease interces • s Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alterati ' of water piping an s r water treatment equi ent Repair or alteration o drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow pr, ective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler stem on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:Wpplications\Fomts- Applications On-Line \2009 Applications \I -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cif of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -01839 Initials: WER Payment Date: 06/11/2012 User ID: 1655 Total Payment: 9,571.97 Payee: PAMELA KUEHL SET ID: 0611 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D12 -196 1,067.51 D12 -197 993.76 •Di2 -198 1, 635..20___) D12 -199 1,856.13 D12 -200 D12 -201 D12 -202 M12 -089 M12 -090 M12 -091 M12 -092 M12 -093 M12 -094 M12 -095 TOTAL: 905.73 779.67 1,141.27 167.70 167.70 177.10 177.10 167.70 167.70 167.70 1,067.51 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 9,571.97 TOTAL: 9,571.97 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES MECHANICAL - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 000.345.830 640.237.114 TOTAL: 5,059.25 1,192.70 3,288.52 31.50 9,571.97 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 r. 1(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: YN L, %4RS 1Z..� Address: 1-10 76'0 � U) et— Type of Inspection: j— INJA1,r Date Called: K7'1 G Special Instructions: o' Date Wanted: ICS -S -(Z_ (.m. p:m: Requester: Phone No: -0G -2(% - cC13Cj Approved per applicable codes. El Corrections required prior to approval. /g COMMENTS: Inspector: kJ) n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: t !� �� ` • ttliN1 GUM COP) PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -198 PROJECT NAME: HALBERT RESIDENCE SITE ADDRESS: 4030 S 117 PL X Original Plan Submittal Response to Correction Letter # DATE: 06 -08 -12 Response to Incomplete Letter # .... Revision # After Permit Issued DEPAR MENTS:I� C. lit()"` 1)uilding Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator so DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06 -12 -12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route NJ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 07 -10 -12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name 5 K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI'052L3 Suite /Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMC0 093L6 5 K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI'976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26 /2010 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.00 12/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 Co es River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.0008 /20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.0001 /23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 8 AMERICAN STATES INS CO 01CD87273810 12/30/2005 12/30/2006 $1,000,000.0012 /06/2005 https: // fortress .wa.gov /lni /bbip /Print.aspx 07/27/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO711C12 BID PACKAGE M -30 3 -53- 0058 -044 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE MECHANICAL VENTILATION. L BUT NOT LIMITED INCLUDES ALL INFORMATION N THE DRAWINGS AND A P P L I CA B L E YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITI1 NEW VINYL - FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIRE`1ENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, P.RNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS TO SUPPORT NSTALLATION OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSt4LLA1ION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL SERVICE. X 20. KNOB AND TUBE WIRING. X Penna. No. PI,.. r^,,►cr approval is subject to errors and omissions. • ytruction documents does not authorize 1 f: or .:1 any adopted code or ordinance. Receipt o: ;��;rt�v�v; Ena vapy and conditions is acknowledged: L � � it ess) City Of Tukwila BUILDING DIVISION By Q Date: REVISIONS r'!r chn^p s sht t hr; rnGc'e to the scope ;•,:•� -'; 1�•i';;' '= prior approval of w . .. 1.tu :°wing Division. rzqu re a new plan submittal it\ •Z p , a 1 tg awtrie ad-Ilona, plan review fees. ,S,7 ,.,R., s J2 PERMIT {t .� FD 2 :cchan :cal LeEi c ricai iUrbing Piping T ukt4Ia I:`1VISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 Vitk City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Planning Division City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 1340600106 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) v B NON SPRINKLERED LEGAL DESCRIPTION: RIVERSIDE INTERURBAN TR5 PARCEL D OF KC SHORT PLAT 511129 REC AF "1112090189 SD PLAT DAF N 90 FT OF TR 5 RIVERSIDE N1ERURBAN TRS DRAWING INDEX T0.0 41.0 A2.0 A2.1 A22 42.3 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, AEBREV, GENERAL NOTES 4 DM INDEX MW MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Shan") Parker E- mail: Sharyn.Parkerekingcounty.gov ARCHITECT: S.M. Stemper Architects P. ..C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E-mail: jerryesmstemper.com melodyesmstemper.com timesmstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 95109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Dylan Turner E -mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: P55 Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: trm ogdenepbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washinnggton St. "200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E -mail: CMaedasjonespaynecom STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronmepsm- engineers.com ECEIVED JUN 08 2012 PERMIT CENTER VICINITY MAP (NTS) S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.2132 3/1/12 0 Ct d -J Z O H z w z z 0 0 v z MPROVEMENTS 0 w w w 0 z ..J W LLI AIP NUMBER 3 -53- 0058 -044 TUKWILA WASHINGTON DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.2132 CLOSET BATH I 24" x 48" EXIST. BEDROOM ATTIC ACCESS PANEL CD" KITCHEN DINING ROOM BEDROOM 2 SPECIAL NOTES: NOTE: LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081. I BEDROOM 3 LIVING ROOM NO WORK IN BASEMENT MAIN FLOOR PLAN 1/4" = 1' - 0" LOWER LEVEL FLOOR PLAN 1/8" = 1' - 0" GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8•.00 AM AND 5:00 PM. 6. PO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 1 ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON NE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. II. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRICT 51-ELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 5O AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT NE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. I. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS 51-IALL BE CONCEALED. 17. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AID FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. I. CONTRACTOR I5 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUI1 POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P1" . A. SOUTH ELEVATION DECK J 54'-1" L_ . . r = —. —.— - 1I Ali - - - -7- - - - LJ- - - • / / / / / n / / / / / / / \ II 11 11 11 IL I1 1 - - - - -- 1 r I . .0 . . . . A� 11 I. I• • -i - - - 1 I 1 L. - ..c. -• I 1 24" x 4S" 1 =kr5T. ATTIC- I J r7/. . . . . . L - - ACCESS'PANEL is I-I 11 .1 1 I I- I- I I 1 1.1 - 1 11 I I / I I- I- I H i , I.1 11 it / / 11 1.1L., I / Fl -F -- . . . . . . . . . / f . . . . . . . • . . . . . . 1-1 / r—II III- / RJR ri ri II II B. WEST ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 2 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR. REF. DOOR SCHEDULE. 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. 0 INSTALL NEW SECONDARY SLIDING GLASS DOOR REF. DOOR SCHEDULE. ': INSTALL ROOF MOUNTED BAFFLE(S) AT EXISTING KITCHEN EXHAUST. REF. 4/A22 FOR DETAIL. OINSTALL THERMOSTAT: COORDINATE WITH MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. c3/16" = 1' - 0" Fib _ J . A . . . THERE ARE 2 CEILINGS IN THIS RESIDENCE. INSTALL INSULATION ON TOP ATTIC SPACE ONLY. C. NORTH ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION D. EAST ELEVATION LEGEND r ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM -- DOOR REFER TO DOOR SCHEDULE 1131 MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW 1111111111111 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT • ATTIC ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. Y: r•'.; ..: ... -. j REF. MECH. i ELECT REF- GENERAL NOTE RECEIVED JUN 0 8 2012 ATTIC INSULATION PERMIT CENTER (:)/ INSTALL BATTERY OPERATED SMOKE DETECTORS SG INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624-2973 REG1S1E+ED 1107 !' :,Coii .141 TEMP STATE C'- 1' 3HINCTOv 3/1/12 081 0.03.2132 0 a_ attt z O t- < z W z z 0 0 00 z AIP NUMBER MPROVEMENTS 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC FLOOR PLANS NOTES A1.0 0810.03.2132 WINDOW TYPES HORIZONTAL XX SLIDER 2. DOUBLE -HUNG 3. CASEMENT 4. FIXED OVER HORIZONTAL XX SLIDER WINDOW SCHEDULE WINDOW NO ROOM LOCATION VIAND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A KITCHEN 1 2' -5" x 3' -0" STAIN /PAINT 1/A2.0 B KITCHEN 1 2' -5" x 3' -0" STAIN /PAINT 1 /A2.0 C KITCHEN 2 2' -10" x 3' -2" STAIN /PAINT 1/A2.0 D BEDROOM 1 2 3' -4" x 5' -9" STAIN /PAINT 1/A2.0 E BEDROOM 2 (CLOSET) 3 2' -4" x 2' -4" STAIN /PAINT 1 /A2.0 F BEDROOM 2 2 3' -4" x 5' -5" STAIN /PAINT 1 /A2.0 G BEDROOM 3 2 3' -4" x 5' -5" STAIN /PAINT 1 /A2.0 H LIVING 4 5' -0" x 5' -0" STAIN /PAINT 1/A2.0 I LIVING 4 4' -2" x 5' -0" STAIN /PAINT 1/A2.0 J DINING 4 7' -6 1/2" x 4' -6" STAIN /PAINT 1/A2.0 (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND NSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDNG TO MATCH (E) SIDING. PRE- PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF- ADHERNG MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY (E) GUS (E) WALL UNPERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING WINDOW HEAD LID WOOD TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) GWB CONTNUOUS SEALANT, TYP. BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN I III WINDOW JAMB SOLID WOOD TRIM WD JAMB LINING SEALANT SHIM ,48 NECESSARY FILL GAP W/ BATT NSULATION BACKER ROD 4 SEALANT 3/4" 3/4" WD. SILL - STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDNG AS REQ'D. MANTAIN (E) COURSING. PANT MODIFIED SIDNG TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING 0 WINDOW SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERING MEMBRANE (E) MUD WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 1 SLOPE 1" min. min. T HEMMED EDGE —1 LEND CLOSURE E HEAD FLASHING DETAIL TYP. 3" = 1' - 0" p1)-- 198 REVIEWED FOR CODE COMPLIANCE 4 APPROVED 'JUN 2 1. 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGI$TEI E:C ' 'rI Ii "r 3/1/12 0810.03.2132 0 a_ Q J z 0 z w z z 0 U z MPROVEMENTS 0 w w w 0 z U_ U w 0 AIP NUMBER 3 -53- 0058 -044 Z 0 C9 z DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2132 DOOR TYPES FLUSH SCW HALF -LITE W/ MUNTINS, SAFETY GLAZING W/ 2 PANELS 5 3 -PANEL SECONDARY SLIDING GLASS DOOR W/ SAFETY GLAZING G EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB /LEVER SET LOCK SET DETAIL SET 1 LIVING A 3' -0" x 6' -8" STAIN /STAIN HW -1/716 DK -4 LOCK -1 1/A2.1 2 KITCHEN B 8' -10" x 6' -8" 2/A2.1 3 LAUNDRY C 3' -0" x 6' -8" 1/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR / EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 1 1"min. HEMMED EDGE 1 L�SLOPE - _J LEND CLOSURE HEAD FLASHING DETAIL TYP. 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF NEW DOOR ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAN (E) COURSING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. PRE- PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF- ADHERNG MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) EXTERIOR SHEATHING CONTNUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE REMOVE (E) WD. SIDING FOR INSTALLATION OF NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDNG TO DOOR OPENNG FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHNG. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) WOOD SIDING DOOR HEAD CONTINUOUS SEALANT BEHIND Z SAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATI.4ER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE Oa AIM ripz "" MN. DOOR JAMB DOOR SILL (E) EXTERIOR 51-EATHING CONTINUOUS SEALANT, TYP. EXISTING FRAMING SOLID WOOD TRIM SHIM AS NECESSARY R=ILL GAP W/ BAT1 NSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3" = 1' - 0" (E) LUP. SIDING PRE- PRIMED, GALV SHEET METAL FLASHING 1U/ END CLOSURE UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED 114 THE FIELD SELF - ADHERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE IS VISIBLE BELOW FLASHING EDGE 2X TAPERED CAP REMOVE (E) SIDING TO FACILITATE NSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PANT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) BLDG. PAPER BACKER ROD AND SEALANT SELF- ADHEARNNC MEMBRANE PLYWOOD DOOR HEAD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF - ADHERING MEMBRANE REMOVE (E) WOOL SIDING AND REPLACE AS REQ'D. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF PENETRATION FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. TYP. AT HEAD AND JAMBS SOLID WOOD LINING. STAIN/ PAINT TO MATCH (E) TRIM. (E) PRIMARY SLIDING DOOR ASSEMBLY. PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. PANT COLOR t0 BE SELECTED IN THE FIELD CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM TRIM- PAINT TO MATCH (E) TRIM SELF- ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS. SEALANT (E) FLOOR/ DECK FRAMING i" MIN. BETWEEN PRIMARY AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB (E) BEVELED WD. SIDNG (E) EXTERIOR SHEATHING LIFT (E) WALL UNDERLAYMENT. LAP NEW UNDERLAYMENT UNDER (E) UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME SOLID WOOD LNING. STAIN/ PAINT TO MATCH (E) TRIM. (E) PRIMARY SLIDING GLASS DOOR DOOR SILL (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WO. FLOOR FRAMING WOOD SIDING - DOOR DETAIL SET 3 " =1' -0" t REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELI2IDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 kE I$1 EK ED .ACTT E,+ TEN/ STATE k!- t' :.)HIN(;T?IW 081 0.03.2132 3/1/12 0 J Z 0 Z w H z 0 z 0 U Z MPROVEMENTS w w w LeO z I-- w AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2132 (E) GWB CARERILLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TIP AT DEAD AND JAMBS. REMOVE (E) WOOD SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D. MAINTAIN (E) COURSING. PAINT MODIFIED SIDING 70 MATCH (E) SIDING. PRE- PRIMED, GALV. SHEET METAL FLASHING W/ FF. END CAPS UNDER SELF - ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. PAINT COLOR t0 BE SELECTED IN THE FIELD PANT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PANT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X BLOCKING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3" = -0 DUCT I CHASE ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. PO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS MO, INSTALL 2X4 STUDS * 16" OTC. J -METAL EDGE AND CAULK JOINT 1- t V SOFFIT DETAIL DEMOLISH (E) GWB NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D t0 ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL I3E CUT RILL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/8" GWB- PANT t0 MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY 3 "= 1' -0" EXISTING ROOF (E) ROOF FRAMING INSULATION DAM DETAIL 3" = 1' - 0" BLOWN IN CELLULOSE INSULATION WITH A COMBINED VALUE OF NOT LESS THAN R -38 INSULATION DAM (E) WALL FRAMING / PREMANUFAC RED ROOF BAFFLE AN- MODEL 634)- EXISTIN DUCTWORK SEAL 411 NAILS WITH ROOF arENT / SEAL SHINGLES TO ROOF CAP ON TOP AND SIDES NOTE= 1. PREMANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURE'S INSTRUCTIONS. KITCHEN EXHAUST BAFFLE DETAIL 1 1/2" = 1' - 0" b1)--1 'I 8 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 RE(y1$TE ED :;,H11 L(;1 0810.03.2132 3/1/12 0 a. J z W 0 0 W 0 z Z W 0) iw- Z Q Z � J Z U I - D < rt J Z f-- Z W 0 W MPROVEMENTS AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC MISC. DETAILS A2.2 0810.03.2132 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 2 -1/2" OVER (E) BLDG. PAPER AT SILL EXTEND 1 3" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 11" MIN MEMBRANE FLASHING AT SILL zo I 5" di. BUTTEffLY LOFTIER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE. EMBED WINDOW HEAD AND JAMB NAIL FLANGE N SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. Q D O O O O O O \\\,. \\\NO O O O ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4 WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN pIAGRAMATI CALL Y. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS WHERE RE l !RED, TRIM (E) BLDG APER AT HEAD TO - . PARE FOR NST LATION OF HEAD FL ING AND WNDOW TR (FOLLOW! ' STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING { FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL 514EATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SWOON FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. L INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. C5 INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER MEMBRANE FLASHING AT JAMB SCALE: NTS TRIMMED EDGE OF (E) SIDING, SHOWN D IAGRAMAT ICALLY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D (E) SIDNG NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 14A5 BEEN INSTALLED. ALLOW 1/8" CLEARANCE BETWEEN FL4514NG AN) 8OT. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER INSTALL HEAD FLANGE FLASHING OVER WNDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.D. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS BEEN INSTALLED. 6 WINDOW FLASHING INSTALLATION SCALE: NTS WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE NSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO 51-EET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. ici REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 • 'TEi3ED 3/1/12 0810.03.2132 0 a J Z 0 z w z z 0 U 0 Z AIP NUMBER MPROVEMENTS 0 w 2 w w 0) 0 z J w w 3 -53 -0058 -044 z 0 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2132 \\\ WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WNDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF ADHEARNG MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE NSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO 51-EET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. ici REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 • 'TEi3ED 3/1/12 0810.03.2132 0 a J Z 0 z w z z 0 U 0 Z AIP NUMBER MPROVEMENTS 0 w 2 w w 0) 0 z J w w 3 -53 -0058 -044 z 0 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2132 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SRC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SEATTLE RESIDENTIAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR AC> OR XX 0 X/Y it / / / / / / / //, DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION 5-- EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL ABBR XXX + f + UP VD RA /EA RG SA SA -+•�- •r I- RA /EA SD 0- 0 0- EQUIP 1410 R x EA MOD NG NG 0 • da DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS PROVIDED UNDER DIVISION FURNISHED /MOUNTED UNDER DIVISION 1MRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 430 <.08 "WG 8 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 150 430 <.08 "WG 8 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2132 3290 3 150 CFM 150 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE 'NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. 199 MECHANICAL VENTILATION CALCULATION PER WAC 51 -51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 112. QF = 75 / (1 X 1 /2) = 150 CFM RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS A Processional Limitad Liability Company 4000 DELRIDGE WAY SW SUM 200 • SEATTLE! WA 98108 (866) 684 -8777 • FAX (206) 624 -8973 THE GREENBUSCH GROUP, INC M1010 LADED t 1t17WMAL Et1 WA 011 N0 1100 wESr SWEET SIIIIE sot sFanF. NI1 ee11e (206) 378 -0660 (206) 376 -0e41 FAX EXPIRES: 9/08/2012 0810.03.2132 TIONAL AIRPORT Z ce W H Z O V 0 Z MPROVEMENTS >- w w w O z 1- u_ U J Z W Lu AIP NUMBER 3 -53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% TUKWILA WASHINGTON PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2132 CLOSET (E)EG BATH 1 24' x 48' EXIST BEDROOM ATTIC ACCESS PANEL CLOSET KITCHEN DINING ROOM BEDROOM 2 u BEDROOM 3 CLOSET LIVING ROOM MAIN FLOOR MECHANICAL PLAN 1 SCALE: 1/4" = 1' -0" NO MECHANICAL WORK THIS SPACE LOWER FLOOR MECHANICAL PLAN LOWER FLOOR MECHANICAL PLAN SCALE: 1/4" = t-0" NORTH r SEE n L_ �r U n E - -- LJ WC -1 150 n — E 8" CHASE, REFER TO ARCHITECTURAL 1 _J L] TYP L 11\ 1 1 1 7 CI I - - - -_J L FULL CEILING SOFFIT, MAXIMIMUM 12" DEEP, REFER TO ARCHITECTURAL �r- _ r J L L r LJ J DRAWING NOTES: ATTIC MECHANICAL PLAN 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51, SECTION M1508.5.4 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -51, SECTION M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK -OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. REUSE (E) MIXING BOX ROOF (E)SUPPLY CEILING VOLUME DAMPER FOR RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE FURNACE c9 (E)RETURN CONTRACTOR TO MODIFY RETURN DUCTWORK TO INSTALL DAMPER AND OSA CONNECTION POC OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE NORTH FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.5.2. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -51, SECTION M1508.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK 2X BLOCKING FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON 2X BLOCKING WALL 1 NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL RECEIVED JUN 0 8 2012 PERMIT CENTER SCALE: NONE bv"-Icie SEPARATE PERMIT'AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS A Psoreeelonal Limited Liability Company 4000 DELRIDGE WAY SW BUTTS 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624-2272 THE GREENBUSCH GROUP, INC reeee....■■■ 100E weal' ,10310 6111EE16UIE 201 52121LE, woii (206) 376 - 0669 (206) 376 -0641 FAX EXPIRES: 9/06/2012 0810.03.2132 TIONAL AIRPORT KING COUNTY INTERN v♦ w w 0 2 0 w w w 0) O z �C W C w AIP NUMBER 3- 53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT TUKWILA WASHINGTON M2.0 0810.03.2132 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOU11ON OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. BASEMENT PLAN 1/4" = 1' NORTH ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION G LIGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. m BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 111111 15 4 DAMPER CONNECTION Q' NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD Jl TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS 1 BRANCH CIRCUIT HOME RUN ei SMOKE DETECTOR X EJ ELECTRICAL METER X TIMER OPERATED SWITCH - AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. Q THERMOSTAT — - — 4ille CEILING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT 0 UNE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR 1" IECf- IANICAL / ELECTRICAL COORD INAT ION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH CLOSET 15,4TN 1 KITCHEN 24" x 4S" EXIST. f�EDRODM ATTIC ACCESS PANEL CLOSET t0 RRJA E DAMPER H DINING ROOM BEDROOM 2 E3E ®ROOM 3 LIVINC7 ROOM CLOSET I�1 MAIN FLOOR PLAN 1/4" = 1' D a - 198 RECEIVED JUN 0 8 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■NOIMillie. INO 0810.03.2132 H 0 a J z 0 z oc w z 0 0 0 z MPROVEMENTS 0 w 2 w w 0 z LL 0 ce Z w ♦♦0 vJ w ce AIP NUMBER 5- 53- 0058 -044 DATE MAR 1, 2012 ISSUED 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2132