Loading...
HomeMy WebLinkAboutPermit D12-199 - VANVOORHEES RESIDENCE - UPGRADESVANVOORHEES RESIDENCE 11814 44 AV S D12 -199 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 .43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400975 Address: 11814 44 AV S TUKW Suite No: Project Name: VANVOORHEES RESIDENCE DEVELOPMENT PERMIT Permit Number: D12 -199 Issue Date: 07/27/2012 Permit Expires On: 01/23/2013 Owner: Name: VANVOORHEES JOHN LUTHER +ELE Address: 11814 44TH AVE SE , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI *052L3 Lender: Name: Address: Phone: 206 - 296 -7437 Phone: 425 235 -5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $65,800.00 Fees Collected: $1,856.13 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D12 -199 Printed: 07 -27 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: —7 ''.):-.7`' L2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit Signature: Print Name: P :0,4—M01\it A C)C:-e--.) Date: 11W71 [a This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, N, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. doc: IBC -7/10 D12 -199 Printed: 07 -27 -2012 6: Ventilation is required for all new rooms II spaces of new or existing buildings and sh in conformance with the International Building Code and the Washin State Ventilation and Indoor Air Quality C 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. doc: IBC -7/10 D12 -199 Printed: 07 -27 -2012 CITY OF TUKWILA, Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: /Avww. ci. tukwila. wa. us Building Perini No. Mechanical Permit No. (- £ 0L Plumbing/Gas Permit No. Public Works Permit No. Project No. t)--1-01 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 11814 44th Ave. S. Tenant Name: Chaitanaya Narukulla King Co Assessor's Tax No.: 3347400975 Suite Number: Property Owners Name: Mailing Address: John Luther VanVoorhees Floor: New Tenant: ❑ Yes WA City State ..No 98178 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:Wpplicattons \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc . Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFOR1 WfION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 65,800 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 21 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applrcations\Fonns- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 1,769 rd Floor 1,060 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 21 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applrcations\Fonns- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO Signature: GENT: 141 (1iS/�� Date: 1i Timothy d enlason, S Stem per Architects, PLLC (206) 624 -2777 Print Name: y p Day Telephone: Seattle Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:Wppltcattons\Fotms- Applications On Lmd2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIP ERMIT INFORMATION - 206 -4W670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping ets being ins ed and the quantity below: Fixture Type: Qty Fixture Type: Qty ixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head Food -waste grinder, ommercial Floor Drain Shower, single head trap Lavatory sh fountain Receptor, indirect waste Sinks Urinals Wa • Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water he and/or vent Industri . , aste treatment intercepto , 'eluding trap and vent, ex ,t for kitchen type grease int■ -ptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) ' lair or alteration of , ater piping and/or water treatment equipment Repair or alterati. of drainage or vent pis Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 • Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device" other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter . Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applicattons\Forms- Applications On-Line \2009 Applications \I -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Cif. of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -01839 Initials: WER Payment Date: 06/11/2012 User ID: 1655 Total Payment: 9,571.97 Payee: PAMELA KUEHL SET ID: 0611 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D12 -196 D12 -197 D12 -198 1,067.51 993.76 1,635.20 aorD4,2ue1 +9B lrea6 ,12•3 t 4 0 D12 -200 D12 -201 D12 -202 M12 -089 M12 -090 M12 -091 M12 -092 M12 -093 M12 -094 M12 -095 TOTAL: 905.73 779.67 1,141.27 167.70 167.70 177.10 177.10 167.70 167.70 167.70 1,067.51 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 9,571.97 TOTAL: 9,571.97 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES MECHANICAL - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 000.345.830 640.237.114 TOTAL: 5,059.25 1,192.70 3,288.52 31.50 9,571.97 INSPECTION RECORD, , Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: y4AvcOR/ -,SS f?cS Type of 1 s ection: /266}c- Gdi6_r•6'-2"v Address: / /8/1/ ye/ 4'v- Date Called: Ay-i1/4L ' Special Instructions: • ///1,,,i Date Wanted: (1-2'7—/Z a.mn CAM.. Requester: S7zin 4 P - r - i . 4 7 , , v - Pao): .... 369_ ... o/,35 EgiApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: 7 �i'm417A,6 - 4 ' ,, % 4 z he,' 6 - A4/p-(V 3� f{04,/, '0 -.�.vy - /- 4,,,1�/i6� P - r - i . 4 7 , , v - , Inspec'gr`. 0141 7 i 1 OEINSPECTION FEE R aid at 6300 Southcent Date: QUIRED/Priorto next inspection, fee must ,be r Blvd., Suite 100. Call to schedule reinspection. i 2 79 CAV CAF LAT GEW EW CRAWL Contractor Gale Contractor Services A Masco Contractor Services Company 16910 59th Ave. NE, Suite 100 Arlington, WA 98223 Installed Insulation Certificate "We certify that insulation material listed here and installed at the following residence surrounding conditioned space meet applicable federal, state, and local specifications." Loose Fill Kraft Unfaced Rigid Foam Cellulose R -Value Thickness ❑ ❑ ❑ ❑ ❑ R -38 12.75" 35 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Laura Halgren (Signature) Title Office Manager Address or Lot Number. 11814 44th Ave South City, ST, Zip: Tukilwa, WA September 10, 2012 eI3 ERI CO COPy • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -199 DATE: 06 -08 -12 PROJECT NAME: VANVOORHEES RESIDENCE SITE ADDRESS,:. 11814 44 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: u li ding ` ivis Public Works Fire Prevention Structural Planning Division n Permit Coordinator IP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-12 -12 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route 1K1 Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07 -10-12 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI *052L3 Suite /Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMC0 093L6SKM CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI *976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26 /2010 4 DEVELOPERS SURETY Et INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.00 12/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 James es River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.0008 /18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.0008 /20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.00 01/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 8 AMERICAN STATES INS CO 01CD87273810 12/30/2005 12/30/2006 $1,000,000.00 12/06/2005 https: // fortress .wa.gov /lni/bbip /Print.aspx 07/27/2012 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO711C12 BID PACKAGE M -30 3- 53- 0058 -044 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE SPEGIF�ICAAtILONSNNGLUDING BUT NO LIMITED INCLUDES ALL INFORMATION IN T1•tE DRAWINGS AND APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WITH NEW VINYL - FRAMED ACOUSTICAL WINDOWS. X 2. GUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. X 10. INSTALLATION OF CHIMNEY CAP. X 11. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X 16. ARCHITECTURAL MODIFICATIONS 10 SUPPORT INSTALLAtIO4 OF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION CF MECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 18. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL SERVICE. X 20. KNOB AND TUBE WIRING. X 1 FEE CPY Permit no. PiP1 r ^vIaw approval is subject to errors and omissions. �.: ; ..¢ of construction documents does not aphorize of any adopted code or ordinance. Receipt n` L;roved Add Copy and conditions is acknowledged: By Date: City Of itikwila BUILDING DIVISION REVISIONS ch Ieaes shall be made to the scope cI v ithr;E=i prior approval of a GuildincJ. Division. t t!'E:require a new plan submittal I :t, i, sv:ude additional plan review fees. ri.,``t; :+is.i: PERMIT RMiT .". s ED FOR: r mechanical E2ctrical :ea-3 Pigng REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION , SITE AND BUILDING INFORMATION JURISDICTION: Planning Division City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341400915 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED LEGAL DESCRIPTION: LOT(5) I AND 2, BLOCK 5, C.D. HILLMANS MEADOW. GARDENS ADDITION TO THE CITY OF SEATTLE PIV. 1, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGES) 64, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES AI.I FLOOR PLANS 4 NOTES AW WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS A2.2 MISCELLANEOUS DETAILS A23 WINDOW FLASHING DETAILS MID LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES t DIM INDEX M2.0 MECHANICAL FLANS AND DETAILS E1.0 ELECTRICAL FLOOR PLANS AND NOTES PROJECT DIRECTORY KiNG COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E -mail: Sharyn.Parkerelcingcounty.gov ARCHITECT: 511. Stamper Architects PL.L.C. 4000 Delridge Way SA Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 20&. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mall: Jerryesmstemper.com metody*smstemper.com tlmCsmstemper.com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 539. 0519 Fax: 206.539.0524 Contact: Mohamed Alt Allaoua E -mail: moharnedessaacousticscom MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 95119 Ph: 206. 318. 0569 Fax: 206.315.0641 Contact: Dylan Turner E-mail: DylanTegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. °200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E -mail: CMaedasJonespayne.com STRUCTURAL ENGINEER: Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 95121 Ph: 206. 622. 4580 Fax: 206.622.0422 Contact: Ron Martinson E -mail: ronnepsm -en !neers.com RECEIVED JUN 0 8 2012 PERMIT CENTER VICINITY MAP (NTS) S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624-2973 COTT TEMPE" STATE O. •Y ASIHINGTON 0810.03.2133 3/1/12 NTERNATIONAL AIRPORT z 0 0 0 MPROVEMENTS 0 w w w 0 z U_ J I-- W 0 CIS U.1 AIP NUMBER 3 -53- 0058 -044 TUKWILA WASHINGTON DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC PROJECT INFORMATION, DRAWING INDEX, DIRECTORY T0.0 0810.03.7% BEDROOM 2 CLOSET CLOSET 1 BEDROOM 1 FOYER r�- BATH I LIVING ROOM KITCHEN MAIN FLOOR PLAN DINING ROOM 1/4 "= 1' -0" SPECIAL NOTES: NOTE: LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02051. NOTE: HARD -WIRED SMOKE DETECTORS, RE: ELECTRICAL. GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL WAVE COMPLETE ACCESS TO 114E RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8•.00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO NE RESIDENCE AND ROOMS IN THE RESIDENCE FOR UEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW I5 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 FM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED. 1. ADD SOLID UJOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS S4EE1 FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. II. ALL WORK AREAS SHALL BE BROOM - CLEANED AT TI-E END OF EACH WORK DAY. 12. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT 514ELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. B. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 15. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET El0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 19. CONTRACTOR IS TO VERIFY t4AT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUtAGE IS EIGI-41 HOURS. POUER MUST BE PROVIDED AT RESIDENCE S:00 AM. 4 AFTER 5:00 PM. 5 422 NINO DECK CED BEDROOM 4 0 SITTING ROOM CLOSET BEDROOM 3 BATH 2 FAMILY ROOM 0 0 UPPER FLOOR PLAN 2 1/4" = 1' - 0" PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 0 2 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF. J DOOR SCHEDULE. 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A22 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. G DEMOLISH EXTERIOR SOFFIT ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 2/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. O BLENDING UNIT LOCATED ADJACENT TO NEW HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. 0 COORDINATE CEILING GRILL WIN MECHANICAL DOCUMENTS. 0 INSTALL VENT BAFFLES) AT EXISING ROOF VENT(S) IN ATTIC. REF. 4/422 FOR DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS. OINSTALL NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. 10 INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER 11 NSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP N OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING ZERO CLEARANCE FIREBOXES. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK N OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. REVIEWED FOR CODE COMPLIANCE ''4' APPROVED JUN 2 1 2012 City of TukvAla BUILDING DIVISION' LEGEND ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE E9 E ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW A. WEST ELEVATION B. NORTH ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION D1� - -Iq9 GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT 4111C ACCESS PANEL CEILING DEMOLITION FOR 4111C PANEL AND WHOLE HOUSE VENT NSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION RECEIVED JUN 08 2012 PERMIT CENTER 50 INSTALL BATTERY OPERATED SMOKE DETECTORS 5C INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 :GOTT .1 STATE .0= 0810.03.2133 3/1/12 0 a. J 0 z w z E 0 0 0 E MPROVEMENTS 0 w w ce w C/) 0 E LL E- E C/) LL AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC FLOOR PLANS NOTES A1.0 0810.03.2133 18' -111 25' -0" TYP. \ 'c // 1_ \\ // 10' -1" ■ \ / Y ri / I+ °. L - - -J 11 // I I J \ p: //- II / II L� I I1 I II I I1 L _1 L II I -1 I \ \\ LL 7 V rL\ // I Y L_1 r - - - --1 I I -I L J�� Lr n 1 17 11 1.1 / / / / / / / / / / //- / / / / / / / / / / / / - - - .r. - -1-r — -1 - - NEW 222 X.30" \ 1 1.1 1. r� — = -V A7TI4 AGC�SS N. I 1 11 PANEL \ 1 Ill 1L_ _11 • \ - - - L: _I.11' E-_-_ - � \ \ \ \ \ A / \ / / / 1 / / / J SPECIAL NOTES: NOTE: LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081. GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO 114E RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO EE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON TI-E SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REM" AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT 514ELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. I. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AID FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. I. CONTRACTOR I5 TO VERIFY TWAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIM111 POWER OUTAGE IS EIGHT HOURS POUTER MUST BE PROVIDED AT RESIDENCE BEFORE 8•-00 AM. 4 AFTER 5:00 Fit T 1 r 1 ` // Ne \ /./ 11 \\ \ 1 // ATTIC PLAN 1/4" = 1' - 0" PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE. 0 DEMOLISH EXISTING DOOR(S), FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE. 3 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A2.2 FOR DETAIL. COORDINATE WITH �:./ MECHANICAL DOCUMENTS. 4 DEMOLISH EXTERIOR SOFFIT ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 2/422 FOR DETAIL. COORDINATE WITH MECHANICAL DOCUMENTS. O BLENDING UNIT LOCATED ADJACENT TO NEW HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. OCOORDINATE CEILING GRILL WITH MECHANICAL DOCUMENTS. OINSTALL VENT BAFFLE(S) AT EXISTING ROOF VENT(S) IN ATTIC. REF. 4/422 FOR DETAIL. 0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL DOCUMENTS. 0 INSTALL NEW ELECTRICAL PANEL. COORDINATE WITH ELECTRICAL DOCUMENTS. 10 INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER 11 INSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACT'URER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING ZERO CLEARANCE FIREBOXES. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION A. WEST ELEVATION B. NORTH ELEVATION C. EAST ELEVATION LEGEND r 1 col ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL DOOR REFER TO DOOR SCHEDULE EXTERIOR STOIRM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW D. SOUTH ELEVATION Da- 1'17 1111111111111 —.1 t...: (•ti;.`''i 1µ.Y.: `..,i: J'}y it E.•:..:: • GABLE END VENT BAFFLE ROOF VENT BAFFLE KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT 4111C ACCESS PANEL CEILING DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 AttIC INSULATION R C VE D JUN 08 2012 INSTALL BATTERY 1�T TER C) INSTALL SC INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER SOFFIT FOR MECHANICAL DUCTING S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624-2973 R.EC;1 STE: -ED A ",..HII'EC:? /lll •'�' SCOTT l 4TEMP STATE 0 t a iINGTQN 0810.03.2133 3/1/12 O ICU Ce J z 0 I- < z CL' W 1- Z z 0 00 z C/) 1- z w `W 0 0 w W w C/) 0 z LL Et aC r0 v J LL AIP NUMBER 3 -53- 0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC FLOOR PLANS NOTES A1.1 0810.03.2133 WINDOW SCHEDULE WINDOW NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT. /EXT. REMARKS DETAIL SET A DINING 1 1' -10" x 6' -3" STAIN /PAINT 21A2.0 B DINING 1 1' -2" x 4' -10" STAIN /PAINT 1 /A2.0 C DINING 2 7' -11" x 4' -10" STAIN /PAINT 1/A2.0 D DINING 1 1' -2" x 4' -10" STAIN /PAINT 1 /A2.0 E BEDROOM 1 3 3' -2" x 3' -10" STAIN /PAINT 1/A2.0 F BEDROOM 1 3 3' -2" x Y -10" STAIN /PAINT 1/A2.0 G BEDROOM 2 1 3' -2 "x 1' -11" STAIN /PAINT 1/A2.0 H BEDROOM 2 1 3' -2" x 1' -11" STAIN /PAINT 1 /A2.0 I BEDROOM 2 3 4' -10" x 3' -10" STAIN /PAINT SAFETY GLAZING REQUIRED 1/A2.0 J FOYER 1 1' -6" x 4' -9" STAIN /PAINT 1 /A2.0 K FOYER 2 5' -9" x 4' -10" STAIN /PAINT 1 /A2.0 L FOYER 1 1' -6" x 4' -9" STAIN /PAINT 1/A2.0 M LIVING 2 T -5" x 4' -10" STAIN /PAINT 1/A2.0 N LIVING 2 7' -5" x 4' -10" STAIN /PAINT 1 /A2.0 0 LIVING 3 4' -10" x 3' -11" STAIN /PAINT 1 /A2.0 P LIVING 2 5' -11" x 4' -11" STAIN /PAINT 1 /A2.0 Q LIVING 3 4' -11" x 3' -11" STAIN /PAINT 1/A2.0 R STAIRS 1 2.-11" x 5' -0" STAIN /PAINT 11A2.0 S BEDROOM 3 3 6' -0" x 4' -10" STAIN /PAINT 11A2.0 T BEDROOM 3 3 3' -2 "x 3' -11" STAIN /PAINT 1 /A2.0 U BEDROOM 4 3 Y -2" x 3' -11" STAIN /PAINT 1 /A2.0 V BEDROOM 4 3 5' -11" x 4' -10" STAIN /PAINT SAFETY GLAZING REQUIRED 1/A2.0 W SITTING 3 3' -3" x 1' -11" STAIN /PAINT SAFETY GLAZING REQUIRED 1 /A2.0 X SITTING 3 4' -11" x 4' -10" STAIN /PAINT 1/A2.0 Y SITTING 3 3' -2" x 3' -11" STAIN /PAINT 11A2.0 Z FAMILY 3 3' -2 "x 3' -11" STAIN /PAINT 11A2.0 AA FAMILY 3 4' -11" x 4' -11" STAIN /PAINT 1 /A2.0 WINDOW TYPES FIXED 2. SLIDER / FIXED / SLIDER 3. HORIZONTAL XX SLIDER TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. HEMMED EDGE 1 SLOPE END CLOSURE HEAD FLASHING DETAIL TYP. 3 " =1' -0" • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 EC1STE D CONTINUOUS SEALANT, TYP. IX WOOD LNER Y/ / // /// / // / //� EXISTING SOFFIT AND FRAME SEALANT r TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WNDOW ASSEMBLY (E) BACKER BOARD SOLID WOOD TRIM WD. JAMB LINING. FINISH TO MATCI4 (E) //--- CONTINUOUS SEALANT, TYP IX WOOD LINER %/ //i Z(// vrr <<<<<<<<O<<ATIi<<i <<<rr «Arrrr; 11: SEALANT 4 BACKER ROD EXISTING SOFFIT AND FRAME SEALANT TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY (E) BUILDING PAPER UNDETERMINED 5IDNG SUBSTRATE J CHANNEL TRIM BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. SEALANT t BACKER ROD J CHANNEL TRIM UNDETERMINED SIDING SUBSTRATE CAREFULLY REMOVE TOP COURSES OF (E) SIDNG AND BACKER BOARD FOR NSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE/ RE- INSTALL SIDING TO MATCH (E) SIDING (E) BACKER BOARD (E) SIDING WINDOW HEAD WINDOW JAMB CAREFULLY REMOVE (E) SIDING. CUT BACK (E) BACKER BOARD AND (E) SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) SIDING (E) EXTERIOR SHEATHING CONTINUOUS SEALANT, TYP. (E) GWB SOLID WOOD TRIM WD. JAMB LNING. FINISH TO MATCH (E) BACKER ROD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD 3/4" WD. SILL - STAN TO MATCH (E) WINDOW SILL SOLID WOOD TRIM SELF - ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". CONTINUOUS SEALANT, TYP. LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB ALUMINUM SIDING - WINDOW DETAIL SET 3" = 1' - 0" REMOVE (E) T -111 SIDING FOR INSTALLATION OF NEW WNDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) T -111 SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PANT TO MATCI4 (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY WINDOW HEAD ACOUSTICAL WNDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE SOLID WOOD TRIM WD. JAMB LINING. FNISH TO MATCI4 (E) SEALANT 4 BACKER ROD REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION (E) GWB CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM IUD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW JAMB /4" TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) T -111 SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING AS REQ'D. PAINT MODIFIED SIDING TO MATCH (E) SIDING (E) EXTERIOR SHEATHING WINDOW SILL BACKER ROD 4 SEALANT 3/4" UAL. SILL - STAN TO MATCH (E) TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM CONTINUOUS SEALANT, TYP. SELF- ADHERING MEMBRANE (E) GWB RECEIVED JUN 08 2012 PERMIT CENTER T -111 SIDING - WINDOW DETAIL SET 3 " =1' -0" 0810.03.2133 3/1/12 0 0 cc J z 0 z ce w z z 0 00 z AIP NUMBER DATE MPROVEMENTS 0 w w ce w co 0 z U cn 3 -53 -0058 -044 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2133 DOOR TYPES FLUSH SCI) (DOUBLE LEAF) 1111 WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW W/ WAGON WHEEL AND 4 PANELS U)/ SAFETY GLAZING c EXTERIOR DBL. LEAF STORM DOOR W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING E FLUSH SCW I•IALF -LITE W/ 2 PANELS W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE WxH FINISH INT. /EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY (DOUBLE LEAF) A 6' -0" x 6' -8" SATIN /STAIN HW -1/626 DK -4 LOCK -1 1/A2.1 2 FOYER B 3' -0" x 6' -6" SATIN /STAIN HW -1/626 DK -3 LOCK -1 2/A2.1 3 SITTING E 3' -0 "x 6' -6" SATIN /STAIN HW -1/626 DK -3 LOCK -1 3/A2.1 4 ENTRY (DOUBLE LEAF) C 6' -0" x 6' -8" 1/A2.1 5 FOYER D 3' -0" x 6' -6" 2/A2.1 6 SITTING D 3' -0" x 6' -6" 3/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. SLOPE r i HEMMED EDGE —1 1 N CLOSURE D OSU L RE HEAD FLASHING DETAIL TYP. 3 " =1' -0" MIT=ZEOr== EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM Y!!!17 YlY/I//II77i !A. 2" MIN. STORM POOR PER SCHEDULE REMOVE (E) T -III SIDING FOR INSTALLATION of NEW DOOR TRIMS AND REATTACHMENT OF (E) SIDING TO DOOR OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND NSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JONTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING t0 MATCH (E) SIDING (E) T -111 SIDING DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD POOR PER SCIHEPULE DOOR SHOE 2" MIN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB EXISTING FLOOR STRUCTURE DOOR SILL SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FRAMING CONTNUOUS SEALANT, TYP. SOLID WOOD TRIM SWIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE T -111 SIDING - DOOR DETAIL SET 3 "= 1' -0" (E) BACKER BOARD (E) SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP of FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) SIDING AS REM) FOR INSTALLATION Of WINDOW 4 FLASHING. REPLACE/ RE- INSTALL SIDING 4 ACCESSORIES TO MATCH (E). J CHANNEL TRIM PRE-PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) BACKER BOARD (E) SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP of FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING. REMOVE (E) SIDING AS REM) FOR NSTALLATION of WINDOW 4 FLASHING. REPLACE/ RE-INSTALL SIDING 4 ACCESSORIES TO R'1ATCI4 (E). J CHANNEL TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE HARDWOOD JAMB BEYOND WOOD DOOR PER SCI4EDULE DOOR SHOE 2" MN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR HEAD SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTNUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE DOOR JAMB /DOOR SILL CONTINUOUS SEALANT, TYP: SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION WOOP FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTNUOUS WEATHER- STRIPPING DOOR PER SCHEDULE ALUMINUM SIDING - DOOR DETAIL SET 3" = 11 - 0" CONTINUOUS SEALANT, TYP. EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. STORM DOOR PER SCHEDULE (E) BACKER BOARD (E) SIDING SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP WI BATT INSULATION WOOD FRAME KER: AS REQUIRED FOR FATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING CAREFULLY LIFT (E) WALL UNPERLAYMENT AND WALL TOP EDGE OF SELF ADHERING FLASHING AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADI•IERNG FLASHING. DOOR HEAD REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF WINDOW 4 FLASHING. REPLACE/ RE- INSTALL SIDING 4 ACCESSORIES TO MATCH (E). J CHANNEL TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB EXISTING FLOOR STRUCTURE DOOR SILL DOOR PER SCHEDULE (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATI -ER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE ALUMINUM SIDING - DOOR DETAIL SET 3 "= 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED BU JUN 2 1 2012 City of Tukwila ILDING DIVISION RECEIVED JUN 0 8 2012 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (266) 624 -2973 RRFGIa1`E.'s+ E:) A -HU EC. O. TT i! TLMT� STATE' ,OF IN TO 0810.03.2133 3/1/12 AIP NUMBER MPROVEMENTS 0 w w w 0 z I- LL U Ct Q J _Q I-- Z L1.1 w cc 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.2133 (E) BACKER BOARD (E) SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF - ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. REMOVE (E) SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING AS REQ'D TO MATCH (E) PRE— PRIMED, GALV SHEET METAL FLASHING W/ F.F. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PANT COLOR TO SE SELECTED IN THE FIELD PAINT VENTILATION FIXTURE, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIORITY ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED UNDETERMINED SIDING SUBSTRATE VERT. CHASE WALL 2x4 FRAMING DUCT PER MECH. SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLATMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING 11 �/ ,.-- - - -- /- / -.- - -- - /i / //- - /// -%' -- / (E) EXTERIOR SHEATHING 2X BLOCKING --- -- 2X2 BLOCKING, 4 SIDES (P.T) 2X BLOCKING AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" WD BASE- PAINT TO MATCH (E) WALLS TRIM FINISH FLOOR AND UNDERLATMENT TO F.O. (E) WALL. BUTT %" TYPE X GYP TIGHT TO SUBFLR r DUCT CHASE NEW GRILL COORDINATE WITH MECHANICAL EXISTING ROOF VENT EXISTING ROOF STRUCTURE CHASE SOFFIT DETAIL HOLD MINIMUM, BUT AS REQUIRED TO COORDINATE DUCT W/ (E) FLOOR AND CEILING FRAMING. DEMOLISH (E) FLOOR (E) FINISH FLOOR DEMOLISH (E) GWI3 (E) FLOOR CONSTRUCTION FINISH FLOOR %" CDX PLYWOOD 2x10 • 16" O.C. 11/2 " =1' -0" CROSS SECTION EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER I-ATERAL SECTION ROOF VENT BAFFLE DETAIL 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. 11/2 " =1' -0" (E) GWB -i- --- / / MECH. DUCTS AND CONNECTIONS - REF. MECH 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES w- Aar Ar EXISTING SOFFIT FRAMING EXTERIOR VENTILATION FIXTURE. REF. MECH: SET IN MASTIC AT EXTERIOR TRIM. EXISTING WALL FRAMING AIR INTAKE DETAIL AT EXTERIOR SOFFIT 3 " =1' -0" LINE OF EXISTING CEILING JOIST BEYOND CASEMENT SASH LOCK PER SPECIFICATION I/2" PAINT GRADE PLYWOOD, FINISHED TO MATCH (E) CEILING: INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS a 24" 0A. EXTEND BLOCKING TO (E) CEILING JOISTS (TYP) (E) GWB Ix FLAT STOCK TRIM FINISHED TO MATCH (E) CEILING ATTIC ACCESS PANEL DETAIL 3 " =1' -0" ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS • 16" O.C. J —METAL EDGE AND CAULK JOINT 0 CHASE SOFFIT DETAIL DEMOLISH (E) GWB EXISTING ROOF (E) ROOF FRAMING INSULATION DAM DETAIL 3 " =1' -0" NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5 /S" ME- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY 1 1/2" = 1' — 0" BLENDING AIR UNIT DETAIL Cr L 11/2 " =1' -0" TAPE AND FEAT BLOWN IN CELLULOSE INSULATION WITH A COMBINE[ VALUE OF NOT LESS THAN R -313 INSULATION DAM (E) WALL FRAMING SUSPEND MECH UNIT FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCtS- REF MECHANICAL HER MUD JOINT � i F ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION EXISTING FLOOR STRUCTURE UCTS PER PLAN WITHIN SOFFIT : MECHANICAL 2x2 CONT. NAILER %" GUS- PAINT TO MATCH (E) TEXTURE 4 COLOR OFRECEIVED F,Jj,I JUN 08 2012 PERMIT CENTER CELING PATCH DETAIL 11/2 1' -0" • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 E:EOSTE's E D IRE::;..; ,Ii TATEn 0: .r at IN(TCi 0810.03.2133 3/1/12 cc 0 a J Z 0 z w z z 0 U 0 MPROVEMENTS w 2 w ce w 0 z LL U ce F— w w AIP NUMBER 3 -53 -0058 -044 0 actF- C7 z DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC MISC. DETAILS A2.2 0810.03.2133 I i i ' J ' ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION EXISTING FLOOR STRUCTURE UCTS PER PLAN WITHIN SOFFIT : MECHANICAL 2x2 CONT. NAILER %" GUS- PAINT TO MATCH (E) TEXTURE 4 COLOR OFRECEIVED F,Jj,I JUN 08 2012 PERMIT CENTER CELING PATCH DETAIL 11/2 1' -0" • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 E:EOSTE's E D IRE::;..; ,Ii TATEn 0: .r at IN(TCi 0810.03.2133 3/1/12 cc 0 a J Z 0 z w z z 0 U 0 MPROVEMENTS w 2 w ce w 0 z LL U ce F— w w AIP NUMBER 3 -53 -0058 -044 0 actF- C7 z DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &DC MISC. DETAILS A2.2 0810.03.2133 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 2 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 I" BEYOND RO. At EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING II" MIN MEMBRANE FLASHING AT SILL J(' 5" BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING At JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW MEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (El BLDG. PAPER AT SILL. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMAtICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. I I O O O D \\ O \\\\ O O \N \\ O O O O ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMAtICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. WHERE RE (E) BLDDG HEAD TO FOR INSt HEAP FL WINDOW TR (FOLLOW MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING IRED, TRIM APER AT PARE LATION OF ING AND STEPS). L HEAD FLASHING PREPARATION SCALE: NTS J (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. INSTALL SHt. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I /8" CLEARANCE BETWEEN FLASHING AND 801. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER 3 SCALE: NTS MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1R" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51-1OIIN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. WINDOW FLASHING INSTALLATION SCALE: NTS 1 9� WOOD TRIM INSTALLATION SCALE: NTS SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL W. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED N 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFEREE TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW' INSTALLATION 3: PETALS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. bp,1cici REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DEL)RIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 con TEMP ATE OF ,dINGTCNt 081 0.03.2133 3/1/12 0 0 ce J 0 z w z z 0 U 0 z AIP NUMBER MPROVEMENTS 0 w w w 0 cc z D 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2133 \\ \\\\ WHERE RE (E) BLDDG HEAD TO FOR INSt HEAP FL WINDOW TR (FOLLOW MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING IRED, TRIM APER AT PARE LATION OF ING AND STEPS). L HEAD FLASHING PREPARATION SCALE: NTS J (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RD. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. INSTALL SHt. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I /8" CLEARANCE BETWEEN FLASHING AND 801. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER 3 SCALE: NTS MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1R" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 51-1OIIN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. WINDOW FLASHING INSTALLATION SCALE: NTS 1 9� WOOD TRIM INSTALLATION SCALE: NTS SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL W. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE 1/4 " -3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED N 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFEREE TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW' INSTALLATION 3: PETALS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 8" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. bp,1cici REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 1 2012 City of Tukwila BUILDING DIVISION RECEIVED JUN 08 2012 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DEL)RIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 con TEMP ATE OF ,dINGTCNt 081 0.03.2133 3/1/12 0 0 ce J 0 z w z z 0 U 0 z AIP NUMBER MPROVEMENTS 0 w w w 0 cc z D 3 -53 -0058 -044 DATE 3/1/12 ISSUED BP M -30 100% CD PROJECT ARCHITECT Jo PROJECT MANAGER ML &TF DRAWN LB &DC WINDOW FLASHING DETAILS A2.3 0810.03.2133 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD Cw DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP H VAC HW H WC HWG HWR H WS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SRC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SEATTLE RESIDENTIAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR AC> OR X 0 X/Y %/////////, DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION -- i- EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 MECHANICAL FLOOR PLANS AND DETAILS M2.0 MECHANICAL FLOOR PLANS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX + DN I "IL f + 4+ + r + -n� (>< -OF- 49-I- 0 -) 04 EQUIP ID�R �. NG— • D'a DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1, BV -2 BLENDING UNIT VENTILATOR 120 1 X 32 "Lx12.25 "Wx8.5 "H 76 X 1 1, 2, 3 X 90 1,2 - SWITCHES (ON, TIMER) 120 1 1, 2, 3 X 90 X 7" 7" X GREENHECK 1 RG -1 25 <08" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL 5. BASIS OF DESIGN: GREENHECK REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 BV -2 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 BV -3 115 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <08" WG 8" 8" CEIUNG ALLGRILLE 1, 2, 4 SG -2 115 <.08" WG 7" 7" CEIUNG ALLGRILLE 1, 2, 4 0G -1 90 <08" WG 7" 7" WALL WALL CAP 1, 2, 3 OG -2 90 <08" WG 7" 7" WALL WALL CAP 1, 2, 3 OG -3 90 <O8" WG 7" 7" SOFFIT GREENHECK 1, 2, 3 , 5 RG -1 25 <08" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL 5. BASIS OF DESIGN: GREENHECK WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2133 BV -1 728 2 90 CFM 90 CFM 1 0810.03.2133 BV -2 728 2 90 CFM 90 CFM 1 0810.03.2133 BV -3 1574 0 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02081 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. THERMOSTAT /SWITCH HOURS OF OPERATION SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. SET BV -2 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. SET BV -3 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION BV -1, 2, 3 PER WAC 51 -51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) 4. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1 /2) = 90 CFM bi):-• rig RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE 4 PERMIT AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS Profeeetonel Limited Idamuty campenl 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • TM (200) 624 -2978 THE GREENBUSCH GROUP, INC • • • • 0 •• 0 ) . )) 1 '"`Mp I° SIRSIREEEF 5506E 201 MUM IR 05119 (206) 375 -0669 (206) 378 -0841 FM 0810.03.2133 0 a Q —J 0 Z z W Z Z 0 V Z z w 2 w 0 cL w w w 0 z LL -I w w AIP NUMBER 3- 53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.2133 CMG_ BEDROOM 2 6 "0 UP CLOSET CLOSET ��l RG -1 U 25 BEDROOM (E1SG LJ (E)SG FOYER TO BV-2 IN ATTIC (E)RG BATH 1 L _ 1 (E)SG TO BV -3 IN ATTIC (E)RG LIVING ROOM KITCHEN DINING ROOM I L MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" 0 Esc SG -2 115 0 H'- RC-1 25 MAIN FLOOR KEY TO VENTILATION ZONES SCALE: NONE J ENTRY TYP (E)SG (E)SG SEE ROOF LINE 00 -1 90 . 90 21 BV -1 UPPER FLOOR BV -2 BV -3 DECK BEDROOM 4 7 "0 UP SOFFIT, MAXIMUM 12 ", REFER TO — ARCHITECTURAL 7 "0 0 R 51 r":I t1D Ft 7 "0 CLOSET CHASE, REFER TO ARCHITECTURAL 6 "0 UP /DN SEE TYP ALL CEILING GRILLES BEDROOM 3 SITTING ROOM TO BV -1 _ IN ATTIC 25 SG -1 140 (E) ACCESS HATCH SEE BATH 2 0 1540 FAMILY ROOM e / / TYP TO BV -3 SWITCH (E) ACCESS HATCH / / / / / / 7 "0 DN TO SG -2 4 "0 DN TO RG -1, e / L DRAWING NOTES: TYP 5 \ UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK —OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. NORTH FLAG NOTES: BV -1, BV -2, BV -3 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.6.4. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. tcrt 7 "0 DN TO OG -3 RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 684 -5777 • PAX (206) 624 -2072 THE GREENBUSCH GROUP, INC .........� A100017 ' AUDm woEO & IECFWdCI1L ENOl1EEitlNO (0) 376 -0660 sneEer SI"' (016) 376- 064"410FM 1 EXPIRES: 9/08/2012 I 0810.03.2133 TIONAL AIRPORT KING COUNTY INTERN W 2 w 0 0- >- 0 W W w 0 z LL E— z L,LI AIP NUMBER 3 -53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHAN ICAL PLANS M2.0 0810.03.2133 ...‘ _ II 111 ill M � a \�," I"�'^ ," J'1 A� :\ 1� � a• d'� , .I . iB ID ' � W� i i'Llt il P 611011 t ■ 0 NI 0 Esc SG -2 115 0 H'- RC-1 25 MAIN FLOOR KEY TO VENTILATION ZONES SCALE: NONE J ENTRY TYP (E)SG (E)SG SEE ROOF LINE 00 -1 90 . 90 21 BV -1 UPPER FLOOR BV -2 BV -3 DECK BEDROOM 4 7 "0 UP SOFFIT, MAXIMUM 12 ", REFER TO — ARCHITECTURAL 7 "0 0 R 51 r":I t1D Ft 7 "0 CLOSET CHASE, REFER TO ARCHITECTURAL 6 "0 UP /DN SEE TYP ALL CEILING GRILLES BEDROOM 3 SITTING ROOM TO BV -1 _ IN ATTIC 25 SG -1 140 (E) ACCESS HATCH SEE BATH 2 0 1540 FAMILY ROOM e / / TYP TO BV -3 SWITCH (E) ACCESS HATCH / / / / / / 7 "0 DN TO SG -2 4 "0 DN TO RG -1, e / L DRAWING NOTES: TYP 5 \ UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51 -51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK —OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND /OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS. NORTH FLAG NOTES: BV -1, BV -2, BV -3 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -51, SECTION M1508.6.4. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. tcrt 7 "0 DN TO OG -3 RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS A Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 684 -5777 • PAX (206) 624 -2072 THE GREENBUSCH GROUP, INC .........� A100017 ' AUDm woEO & IECFWdCI1L ENOl1EEitlNO (0) 376 -0660 sneEer SI"' (016) 376- 064"410FM 1 EXPIRES: 9/08/2012 I 0810.03.2133 TIONAL AIRPORT KING COUNTY INTERN W 2 w 0 0- >- 0 W W w 0 z LL E— z L,LI AIP NUMBER 3 -53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHAN ICAL PLANS M2.0 0810.03.2133 if DECK 4 "0 DN 7 "0 DN BEDROOM 4 4" 1 TO BV -1 SWITCH SITTING ROOM SEE SG -1 140 — L 1 8 "0 DN TO SG -1 1 " CLOSET L J r L� r 6 "0 DN 4 "0 DN T 1 L �F CLOSET V u \ BATH 2 111 8 „0 TO BV -2 SWITCH BEDROOM 3 ATTIC MECHANICAL PLAN FAMILY ROOM 8 "0 DN TO SG -1 SCALE: 1/4" = 1' -O" NORTH INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS RETURN AIR DUCT OUTSIDE AIR DUCT HOLD TIGHT TO STRUCTURE USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. ATTIC MOTOR ACCESS FILTERS ACCESS BLENDING UNIT INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON GRILLE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL SCALE: NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN NOTES: 2X BLOCKING FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON 2X BLOCKING WALL 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W /ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL SCALE: NONE DUCT PER PLAN FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD '2X BLOCKING SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING NOTES: 1. INSTALL VENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GREENHECK EXTRUDED LOUVER SOFFIT LOUVER INSTALLATION DETAIL SCALE: NONE bP X49 RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 96106 (806) 684 -8777 • FAX (806) 824 -2272 THE GREENBUSCH GROUP, INC 0'S•1S•S••/ MIND motI22019*.oii ao (206 3� 6 -0660 r (2006) 378.00414 FM EXPIRES: 9/08/2012 cw w 0 0_ >-, w 2 w ce w co 0 F- u_ LL! 0 co ce AIP NUMBER 3 -53- 0058 -044 DATE 3/1/2012 ISSUED GROUP 21 100% TUKWILA WASHINGTON PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS AND DETAILS M2.1 0810.03.2133 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. SYMBOL ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. EKEDROOM 2 CLOSET CLOSET BEDROOM 1 L - DEMO EXISTING PANEL USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL NEW PANEL. SEE DETAIL AND PANEL SCHEDULE FO`r'ER EXISTING HARDWIRE SMOKE DETECTOR 44TH 1 METER AND F1NAL ----413 CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID PROVIDE NEW WEATHER HEAD, MAST GUYS AND ANCHORS AT EXISTING LOCATION. PROVIDE NEW ROOF FLASHING. TRIM VEGETATION TO PROVIDE MINIMUM 36" CLEARANCE AROUND SERVICE WIRES PER SCL REQUIREMENTS. MP /25 KITCHEN DINING ROOM MAIN FLOOR PLAN L 1vING ROOM PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL INCLUDE ALL UTILITY SERVICE FEES IN BID. 1/4" = 1' ENTRY NORTH MECNAN f CAL / ELECTRICAL COORDINATION ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION G LIGHTING OR POWER PANE EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. ® 15 BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 I I I I 1 15 16 DAMPER CONNECTION ❑I NON -FUSED DISCONNECT SWITCH C MAST, WEATHERHEAD OS' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN @ SMOKE DETECTOR X ELECTRICAL METER I SWITCHES (ON, TIMER) TIMER OPERATED SWITCH 1 X .AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. 0 THERMOSTAT - - - E CEILING MOUNTED FIRE ALARM - VISUAL STROBE LIGHT ® LINE VOLTAGE FIRE ALARM SMOKE /CARBON MONOXIDE DETECTOR MP /25 KITCHEN DINING ROOM MAIN FLOOR PLAN L 1vING ROOM PROVIDE NEW METER BASE, RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL INCLUDE ALL UTILITY SERVICE FEES IN BID. 1/4" = 1' ENTRY NORTH MECNAN f CAL / ELECTRICAL COORDINATION ITEM N0. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH DECK EEDROOM 4 G1 OSET CLOSET BEDROOM 3 SITTING ROOM MP /23 EXISTING HARDWIRE SMOKE DETECTOR BATH 2 FAMILY ROOM UPPER FLOOR 1/4" = 1' gif RECEIVED JUN 08 2012 PERMIT CENTER SEPARATE PERM,TAND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2073 ■ N�IN��IIS. INO N M MUM TAM% WA � SINE � IMAM= OM WI Alle FAA —a..r 0810.03.2133 0 0 J z 0 I- Q z w z O 0 z MPROVEMENTS 0 w 2 W tt w 0 z w 0 w cc AIP NUMBER 5 -53- 0058 -044 DATE MAR 1, 2012 ISSUED 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2133 PANEL MP LOCATION:: SERVING: - RESIDENCE 120f240 11G LT, 10,000;AIC, 1 PHASE, 125 AMP with MAN IRE. CKT LOAD DESCRIPTI A P EXISTING UNIT 3 5€If2 5 EXISTING UNIT 3012 7 9 EXISTING UNIT 11 13 EXISTING UNIT 15 EXISTINGUNIT 17 EXISTING UNIT 19 EXISTING UNIT 21 3012 2W1 5011 5! 6012 23 BLENDING UNIT 25 BUNGING UNIT 27 2011 2011- 29 31 33 35 37 39 41 NP fA LOAD DESCRIPTI 2011 EXISTING UNIT 2 2011 2011 2011 EXISTING UNIT EXISTING UNIT 4 6 2011 20 2011 2011 2011 2011 EXISTING UNIT EXISTING UNIT EXISTING UNIT EXISTING UNIT EN STING UNIT EXISTING UNIT 0 2 4 6 8 EXISTING UNIT 20 2011 2011 20/1 20/1 2011 2011 EASTING UNIT EXISTING UNIT EXISTING UNIT EXISTING UNIT PROVISION 22 24 26 28 0 PROVISION 20/1 PROVISION 32 34 36 8 40 42 PHASE LOAD PHASE A= PHASE B= OAD TYPE LM TOTAL LOADS CONN. LOAD KVA COMPUTED LOAD A P ❑ ISOLATED GROUND BUS RANTIGHT NEMA-3R ENCLOSURE ❑ I FEED THRU LUGS ............... 0 ;I DOUBLE LUGS N BKR SHUNT TRIP ® SERVICE ENTRANCE LABEL 0 PANEL SKIRTS ® SURFACE 0 FLUSH REMARKS: PROVIDE NEW RIGID STEEL MAST, WEATHER HEAD AND CONDUCTOR PIGTAILS PER SCL REQUIREMENTS. FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY SERVICE FEES IN BID. PROVIDE NEW MAST GUYS AND ANCHORS ROOF 2 "C, 3 #3/0 CU METER AND FINAL CONNECTIONS BY SCL. INCLUDE ALL UTILITY CHARGES IN BID. PROVIDE NEW SERVICE DROP FROM POLE TO HOUSE BY SCL. ALL FEES PAID BY CONTRACTOR. PANEL MP 200A 120/240 1 —PH, 3W in 2 "C, 3 #3/0 CU.& GND PROVIDE METER BASE PER SCL STANDARD #DU13- 4 /NMT -30 PROVIDE #4CU GROUNDING ELECTRODE CONDUCTOR AND GROUND RODS PER CODE. MAX 10 OHMS TO GROUND PRO DE NEW NEM —3R S.E. RATED PAN BOARD. INTER EPT AND EXTE D EXISTING CIRCU TS AND CONN :CT TO NEW BREAK RS. PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON DRAWINGS. ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST. PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING CONDITIONS. VISIT THE SITE TO ESTABUSH EXACT CONDITIONS PRIOR TO BID. NEW SERVICE DETAIL SCALE:NONE ba, (co RECEIVED JUN 08 2012 PERMIT CENTER SEl: RATE PERANTAND ERROVAL R fUIRED S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■NS1N■ ■110, 1110 MN w � M X01 1111111111111111111 UMW n.IMO FAX MI w Mr 0810.03.2133 0 0 J z 0 LIB w z 0 z MPROVEMENTS 0 Cw w w U) 0 z u_ ce 1— z ce z 0 V z C/a DATE MAR 1, 2012 ISSUED 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.2133