Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-209 - WESTFIELD SOUTHCENTER MALL - RIALTO JEWELERS - TENANT IMPROVEMENT
RIALTO JEWELERS 810 SOUTHCENTER MALL D12-209 City A-Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 810 SOUTHCENTER MALL TUKW Suite No: Project Name: RIALTO JEWELERS Permit Number: D12 -209 Issue Date: 07/03/2012 Permit Expires On: 12/30/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: BRIAN WILSON Address: 33103 30 AV SW , FEDERAL WAY WA 98023 Contractor: Name: DUN -RYTE CONSTRUCTION LLC Address: 33103 30 AV SW , FEDERAL WAY WA 98023 Contractor License No: DUNRYCL911DP Lender: Name: Address: Phone: 253 517 -3173 Phone: 253 517 -3173 Expiration Date: 06/17/2013 DESCRIPTION OF WORK: DEMOLISH TILE FLOOR, FLUSH OUT WEST WALL WITH METAL STUDS, INSTALL 5/8" SHEET ROCK, AND RAISE EXISTING DROP CEILING. Value of Construction: $2,000.00 Fees Collected: $212.40 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -209 Printed: 07 -03 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Number: 0 Size (Inches): 0 N Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this per�� .- Signature: G�2V1:/! i Date: ! ` ; - / Z Print Name: 1/11/71/ //$ y This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -209 Printed: 07 -03 -2012 7: All construction shall be done in confor a with the approved plans and the require of the International Building Code or International Residential, International Mechanical Code, Washingt tate Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: IBC -7/10 D12 -209 Printed: 07 -03 -2012 26: All new sprinkler systems and all mod' ' ions to existing sprinkler systems shall have department review and approval of drawings prior to installation o�dification. New sprinkler systems and all m ations to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior, to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2328) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Post address on storefront per approved Westfield standards. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 34: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -209 Printed: 07 -03 -2012 CITY OF TUK Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://wWw.TukwilaWA.gov Building Pelt No. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION t / /King Co Assessor's Tax No.: _ Site Address: 8/C) .50Gej /7i4,L/}0jL/ �. I14'14 . Suite Number: Floor: // ,574 Tenant Name: ,14116> 7 /; , 4,'4 $ New Tenant: ❑ • Yes El „No 19-9M1- Got° PROPERTY �OWNERI Name .W/ // / /=D 5 :°404 /e /_%SS72 z rgsszSOCIGW/Y7.1/- !z/Ita- City? - Statue, Ziieigjg //e1`I CONTACT PERSON - person receiving all project communication ttom�,, Name: /iL4/ /(�//�� �,/Y Address:3y /a 3 3d7-,l4_ 557,6.) %J C''/^/ / a4/ Stat,A Zip %023 P p 3 S/7- 3/73 yD -/363 Email8c1 5 1/41 ''� ' ,11‘r ci, f?- /y4c. GENERAL CONTRACTOR INFORMATION Name: Company eW /?rn:`�- C'5 e7- z L,C Address:3_7/ 03 307*/ 4_ SGv City` ^rl)„:772 / zm/tate: Zi 9 2< Phone a 75:3_70!",/.3e.3 Contr Reg hula ` cl, 90/ tpate: Tukwila Business License No.: G 493 0A mita H:Wpplications'Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh 11 ARCHITECT OF RECORD Name: Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO -206- 431 -3670 Valuation of Project (contractor's bid price): $o,?, %®'' Describe the scope of work (please provide detailed information): / - Ate- Existing Building Valuation: $ r'MO 77/2 ' ' " j ��G�5, d/lf 2-2P —le, 4Zg2� Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: pke No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ly Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Other (specify) ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications'Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existin Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Pt Floor 2/6 h 7/e '44 A/ 2 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: pke No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ly Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Other (specify) ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications'Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NPR QR AUTHORIZE AGENT: Signattu Print Name: te3R /.4 / /4Sev/Y Day Telephone: Mailing Address: 3329 3 *,e2 Tyke H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Date/3/ z /7?—e>--s‘1460' 4?45Y City State Zip Page 4 of 4 PUBLIC WORKS PERMIT INFTION — 206 - 433 -0179 1 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. 1 Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ ... alley View ❑ ... Renton ❑ .. Sewer Use Certificate ❑ ... ` er Availability Provided ❑... Highline Septic System: ❑ On -site Septic System — For on -site sep system, provide 2 copies of a current septic design appr' d by King County Health Department. 0... Renton 0... Seattl Submitted with Application (mark boxes whi ❑ .. Civil Plans (Maximum Paper Size — 22" x ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Rep • ❑ .. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Eas nt(s) 0... Maintenance A ement(s) ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0... Right - ' ay Use - Profit for less than 72 hours ...Rig, of-way Use — Potential Disturbance k in Flood Zone Sto ' Drainage ❑...Abandon .tic Tank ❑...Curb C ❑... Pave • t Cut ❑... Lo • d Fire Line ❑...Grease Interceptor 0... Channelization 0... Trench Excavation ❑ ... Utility Undergrounding ❑ .. Permanent Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Water Only Meter Size WO # ❑ .. Deduct Water er Size " ❑ .. Sewer Main Extension s lic ❑ Private ❑ ❑ .. Water Main Extension ublic ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property a Number of Public Fire Hydrant(s) ❑ .. Water .. Sewer ❑ .. Sewage Treatment Monthl Service Bil to: Name: Mailing Addre Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-209 Address: 810 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/14/2012 Applicant: RIALTO JEWELERS Issue Date: Receipt No.: R12 -01865 Initials: User ID: JEM 1165 Payment Amount: $212.40 Payment Date: 06/14/2012 09:57 AM Balance: $0.00 Payee: DUN -RYTE CONSTRUCTION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Cash Authorization No. ACCOUNT ITEM LIST: Description 212.40 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $212.40 126.00 81.90 4.50 doc: Receiot -06 Printed: 06 -14 -2012 INSPECTION RECORD Retain a copy with permit. INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206)4.3.1 -3670 Permit Inspection Request Line (206) 431 -2451 Projec • i JJ�%`�j r. - A Type of Inspectiopn: * `. IA Address:. & -(o SC_ M (( Date Called: Special Instructions: Date Wanted:. a.m. ,p-nr Requester: Phone No:„ NI Approved per applicable codes. Corrections required prior to approval. COMMENTS: My Inspector: req4e 4 / 1 ❑ REINSPECTION FEE REQUIRED. Prior to next inspection ',fee must be -. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �} (2 1 Probe • , �— K, A-{TO J ewe 1 fr Type of Inspection: f y S mss. L- /1r Add s:CO Sc 4�/ Date Called: ___ Special Instructions: Date Wanted: a � c a mm. _let__ .:� �I Requester: Phone No: 25' 3 - -74®- (3 0.3 Approved per applicable codes. LJCorrections required prior to approval. COMMENTS: Inspedtor: AA a REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection' Request Line (206) 431 -2451 Project( (A `� v . t4 `6- Type of Inspection: . s o e E 1.-.: A. Adds!.!: (0 _S C--A4 C-1_ Date Called: Special Instructions: t✓ o r 5 3 c _. o ( X . t -C -N:31`34"-) Date Wanted �a rra:• 7 ' 2 � ! i �p.m. Requester: Phone No. 2 ''''.1-44 0 'f 3 ,/ � ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: fJ( Q/r171.- `spectoy�� E11SPECTION FEE REQUIRED: Prior to next inspection, fee must be ' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date? 27 i INSPEeTION NO. • INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: "Al--C 0 r Ci. -) u Q c, Type of Inspection: "r(--1/43 ✓ -- t/1 7�gd Address: Date Called: - '7/ &_ r>DY TO ,')i? -z 07 ); N Special Instructions: Date Wanted:. aT✓m Requester: Phone No: 741 O— I3G 3 N. ,....7.1^- Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: A 7/ / ) /L-Pg7r76 ' 4)4)(A//14 ✓ -- t/1 7�gd A%: Z/ Z _ 07 G M1/ '7/ &_ r>DY TO ,')i? -z 07 ); N N. 1 ECTION FEE REQUIRE Prior to n(xt inspection. fee must be t 6300 Southcenter Blvd.. Site 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit L$F PERMIT NO. CITY OF TUKWILA BUILDING DIVISION_ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: N-74 L 7-0 c ' we t F',P Type of Inspection:. ., -r.‘.1 ,'3 Address: _ el /0 S© ('.J i ir/ <J /i Date Called: Special Instructions: 6./g65 -©/ Date Wanted:. 7 - 2 4 7 — / . . . _a.rt., Requester: , / Phone No: „2s3- 767:17,: ❑ Approved per applicable codes. 1orrections required "prior to approval. COMMENTS: ( 11 t') /, C 41(9 , - ivca •'r Ilispecto . Date: t)rt_ REI SPECTION FEE REQUIRED. Priodto next inspection' fee must be . 6ard at 6300 Southcenter Blvd., Suite 100. Call to sch'edule`reinspection INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj�c( A W` „ �_n � t, t'r w -C Type of Inspection: ! 5 c( 'A Address: f to 5e_mmi Date Called: Specia Instructions: I Date Wanted:. "......rrn - 7,.-73 —(L. p.m. Requester: Phone . __Ka_ , 0 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: D/ J\ u \\ 1 5 /U t1 k t I \ Inspector'„ Date ✓ �Z.. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Zit -z ' Project: /a TD f,.C`J$ 1..e25 Type of Inspection: f ,2 fry, /ilj C� Address: �3' in •C) f4/7 Af4 // Date Called: Special Instructions: 6f%�.X6A/ /0 --�l/ / 9/ Date Wanted: . 7'7 - Z 0 -- / "' Requester: Phone No: _ 7 4 , / b — / 3 3 6 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: \/ nspector: Da Y-zo ❑SI FEE REQUIRID. Prior to nect inspection, fee must be p {d at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . - (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1,214 L rO o9F6 Gr? S Type of Inspection: f, m,...1, Ad 4. Address: 6/6 M/7 // Date Called: Special Instructions: Date Wanted:. . - a.m. Requester: Phone No: - -.2-S- 7 L/ Approved per applicable codes. pCorrections reqUireci prior to approval.-• � c_ COMMENTS: N (0,0/ AN/42i NI¢FCIF/ Inspec • r: Dat REI SPECTION FEE REQUIRE °. Prior to1hext inspection. fee must be p d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit i2- /ca. DL -0-7A . fi >t_2 3 f PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 Project: Fire Alarm: Type of Ins ction: Address: axckij giC Suite #: 5 . c _ , Al t. Contact Pp son: Special Instructions: Phone No.: 4pproved per applicable codes. Corrections required prior to approval. COMMENTS: f -(4 C3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector.: Date: /z Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: State: Word /Inspection Record Form.Doc 6/11/10 Zip: T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit - 9 /ca - S /Yt PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: e 9 4 (' A S e i,-) e ( Type of Inspection: S P Cev- -el- Address: c‘) 0 S . Suite #: . ,4- L L Contact Person: Special Instructions: Phone No.: R- .Approved per applicable codes. Corrections required prior to approval. COMMENTS: ' ;( P Needs Shift Inspection: . Date: map Z Sprinklers: Fire Alarm: Hood & Duct: Monitor:. Pre -Fire: Permits: , ' � Occupancy Type: /1 Inspector: 0 s-(9._ Date: map Z Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit 2- 2o 1 INSPECTION NUMBER PERMIT NUMBERS. CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: -�' P r /J- V -v-e /el S Type of Inspectio : / 6 V r-./ / �� / TV i Adcress: Suite,,# : j/O 5 / Mar // Contact Person: �`gh O. / / &n Special Instructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /0o r"' p�o,h5 o h _pP Needs Shift Inspection: Sprinklers: Hrs:: , Z4—s Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: \ Inspector: ��. Date: v J/-Z., Hrs:: , Z4—s 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspecion. BiliingAddress Attn: Company Name: Address: 'City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Plan for new Rialto Jewelry Store: roirl sus, .„ Remove tile flooring. • Fir out the west wall 3.5" to ceilin g height. ht. • Framing will be 2 "x4" metal studs. • Existing drop ceiling will be raised about 16 ". • Cut and raise soffit 16 ". • Electrical and plumbing will be completed at this • Install 5/8" sheetrock; mud, and tape. • Paint. • Install ceiling tiles. • Install new carpet. • Install new cabinets and finish electrical. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 3 2012 City of Tukwila BUILDING DIVISION stage. P12 crtr OFmNoll JUN 1`+2012 PERMIT CENTER 20°I •J� NORDSTROM macys ZQ, 0 0 10 0 Tito • • ❑ 0 0 Ca 1 0 r. n r•1 / D The document is diagrammatic and is intended only to show the demised premises of the project (hatched areo.) It does not purport to show exact dimensions no the final location of any mechanical, electrical, structural or architectural element. Further, the londlord reserves the right to odd, eliminate or modify any such element, os may be required from time to time. Tenant space dimensions, unless otherwise noted are to the centerlines of tenant partitions and column grids, lace of exterior walls and to the outside face of service area partitions adjacent to the tenant space (viz. corridors, closets, and stairs.) REVIEWED FOR CODE COMPLIANC E APPROVED JUL 0 3 2012 City of Tukwila BUILDING DIVISIO4 SOUTHCENTER Level 1 11/01/11 232 TBD 216 S.F. EXHIBIT A2 62a 6/ 95f 7L7/ b'/= 5;9/W7 /htss - 36 1/16 -- 230 — 36 1/16 — ; -- 36 1/16 — ; -- 36 1/16 13 1/2 l -] - 1/c6 — 1 — 36 1/16 — 2 3 4 5 5A4 E9 G.cv4/ 14 f Griv3mie?L #/y do ,2/N, ao 4 NM) (U (1.1'' 1 l 13 G,'( s. -t , 1 sItC�+ L iCL, ;loot; & z.I Ciri REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 3 2012 inf 1 tv g of Tukwila BUILDING DIVISION ss 12 11 10 9 - -- 44 3/8 -- 34 1/8 -- ; -- 3$ 'E'. �'� - 34 1/8 48 30 1!-, N T i cagiivey, ? 4)/2./.., a 047L1 0 710 6heaWood Place BIrkanfe+a OR> 97016 Phone: (603 ) 755 -2444 Fax: (503) 755 -2446 jewiery store Floorplan option A Room 1 Current Date: Apr 30, 2012 Scale: NTS T: \PLOT FILES 2002 \AS IS PLOT FILES \Soulhcenler_AS I5_L.dwg • 850 • 25_11 J2,8261 Da50 JAPAN 3675s! NORDSTROM 3 LEVELS 165,900,1 ABET KA2 45010 THE WALKING 00127415 ®19030 ®vER12CH 005£5055 • 211131 .11 BADE w nA807205ON • 235133 8843� macys b 4 LEVELS Hn 9^ ��� MEI IIJ 6 738.9107 .12 2 % �, till- 16R JJ� ]- 5'�Cj1yA A td if 06EST . 100,1 6 12Cf1_ .14r--9:. • 5Uet asa $ gq • w W� � � I a s a f¢ A e i raAF6V0t5 AEL KWtS f k1 MEYER 153300 15500 E3_. 26_0 i6-S- 1. -0 @ =P 9108113£0' 90221,18.131 9075 0890 180sf :907311800i96711 JCPenney SHEKH SHOES 215331 • 839505551 CAFE 11526 si OAKLEY 13680 GCDIVA 950 0 '7.T15 1462,19 PRETZEL YOPOF 809080905 3 LEVELS 171,530,1 A51 512 5080 0 I5: R CITY JUN 1 4 2012 3 LEVELS 2722512' REF rr' :3.mu:LKa■11ae REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 3 2012 City of Tukwila BUILDING DIVISION PERMIT CENTER 182733 .22001 .1002 113531 O9KE5 CF106VER H5I5E 66390 (6) 2) 1.6 I) 6) @) 6:) 66) lei Westfield, LLC 11601 w89NERw. t 2TH f1.00. LOS MMUS CA. .0025 1)1N 470856 AS -IS LEASE PLAN 00 D TNa 00.1.008 b 11■22.08111 006 Mow. only .0>ob0 12 0002N100s. locations. 0480063 802 pn090+W Wm2.0a. TM M.. location. existence or k2dty of any element .p.cKk 006200 0 m.y 9..22.2 049.13 0000211135.23 Me .02* u 0 .mane discretion of 0n L.fA3d. F.W. to verify actual e n�l d nap. 232, of the tenant SCALE 03 60 STORAGE LEGEND 0.0 .00 .20 241 5020 722 .08 1270 5320 0Ad 8400 .04 10841 SSW 6081 5618 582 10101 24 562 2540 8670 470 5886 1900 5700 000 3701 1741 8702 1210 903 243 811. 820 51459 1950 81460 1620 81470 1290 West/le[c[ Southcenter 633 SOUTHCENTER MALL SEATTLE. WASHINGTON 98188 SOUTHCENTER May 18, 2012 11881 1 Of 3 D f Dr N - hey co/Y.si 1.4 c 253- 7VP -/ Y6 3 EX/57—/A/4 /V4eJ (5-# z..te-z(.__ p l r %Z SW FgA- /�' M F% G ODE /� /' p/G - � t rte/ Lr)JL1, f3 576" l o 1.�tz c T coo s45' x /$ // C 1.g 2 c.�=iG i/v /6" f (2 - .2/6 z161� o" 3 /z REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 3 2012 City of Tukwila BUILDING DIVISION l �L 1/‘?6,' /‘? TSofin 'auk JUN 1 4 2012 PERMIT CENTEE LL) EST- 7' /) g 56077G�/YTER / /e1 F z City ®f Tukwila June 19, 2012 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Brian Wilson 33103 30th Av SW Federal Way, WA 98023 RE: Incomplete Letter #1 Development Permit Application D12 -209 Rialto Jewelers — 810 Southcenter Mall Dear Mr. Wilson, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 14, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Dave Larson at 206 431 -3678 if you have any questions regarding the following comment: 1) The plans as submitted are not adequate. Pictures are not acceptable. Provide detailed plans stamped by an architect of work to be performed. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, c Bill Rambo Permit Technician Enclosures File: D12 -209 W:\Permit Center \Incomplete Letters\2012\D12 -209 Incomplete Ltr # I.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PEW-COON Y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -209 DATE: 06 -29 -12 PROJECT NAME: REGALIA SITE ADDRESS: 810 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: frvici ding Division Public Works ❑ Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07 -03-12 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -31 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *EMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -209 PROJECT NAME: RIALTO JEWELERS SITE ADDRESS: 810 SOUTHCENTER MALL DATE: 06/14/12 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: Building Division ® Fire Prevention ®dnning Di�ils' ibn i N/- (oir1, Public Works Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 06/19/12 Incomplete Not Applicable ❑ Comments: Permit Center Use Only r INCOMPLETE LETTER MAILED: lo`&ct "I 2- LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg f Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: �1 Please Route n Structural Review Required n No further Review Required I I REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/17/12 Approved ❑ Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 02/29/12 City f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: / 2 - Response to Incomplete Letter # [ ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: /4/Gt /A1 Project Address: �j /t' SOC! /�! �'h�� 7 7A1,6* / Contact Person: �Z/ f t t/ /tS�/x Phone Number:a5 ?W - A/%1�3 Summary of Revision: / CITY OF1"UKWfA 1 JUN 2 9 20121 PER&41T watip Sheet Number(s): "Cloud" or highlight all areas of revision including date of revis'o c Received at the City of Tukwila Permit Center by: Entered in Permits Plus on b t�iZ H:\Applications\porms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople P1ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L6J to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name DUN -RYTE CONSTRUCTION LLC UBI No. 602903765 Phone 2535173173 Status Active Address 33103 30Th Ave Sw License No. DUNRYCL911DP Suite /Apt. License Type Construction Contractor City Federal Way Effective Date 3/17/2009 State WA Expiration Date 6/17/2013 Zip 98023 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date WILSON, BRIAN CURTIS Partner /Member 06/17/2011 Bond Amount BUELL, GARRY E JR Partner /Member 03/19/2010 06/17/2011 WILSON, MICHELLE MARIE Partner /Member 03/17/2009 03/19/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 American Contractors Indem CO 100196019 05/18/2012 Until Cancelled $12,000.0005/21 /2012 3 American Contractors Indem CO 100161138 04/18/2011 Until Cancelled 06/10/2012 $12,000.0006/17 /2011 2 American Contractors Indem CO 100117878 03/19/2010 Until Cancelled 05/12/2011 $12,000.0003/19 /2010 1 DEVELOPERS SURETY Et INDEM CO 357357C 01/28/2009 Until Cancelled 03/14/2010 $12,000.0003/17 /2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Security National Insurance NA102474600 05/18/2012 05/18/2013 $500,000.0005/22 /2012 4 Coavigators Ins qaa01437022 05/18/2012 05/18/2013 $500,000.0005/21 /2012 3 Coavigators Ins 4610140327 04/18/2011 04/18/2012 $500,000.0006/17 /2011 2 NAVIGATORS INS CO 4610111602 03/19/2010 03/19/2011 03/03/2011 $500,000.0003/19 /2010 1 DEVELOPERS SURETY Et INDEM CO BIS0000082701 01/28/2009 01/28/2010 12/03/2009 $300,000.0003/17 /2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 07/03/2012 LEASE LINE ADJACENT TENANT SPACE - NO WORK THIS AREA ALIGN GWB AT FURRING WITH (E) GUJB AT COLUMN COVER 12' -0" LEASE LINE ADJACENT TENANT SPACE - NO WORK THIS AREA CQLQ �J1, GWB t0 BE PAINTED COLOR - TBD CARPET - TYPICAL --\ FLOOR MOUNTED CASEWORK/ FIXTURE FLOOR MOUNTED CASEWORK/ FIXTURE e 44" CLEAR FILE COPY Pam* No. V-=2-J:) LEASE LINE (E) ADJACENT TENANT STOREFRONT TO REMAIN. (E) ALUMINUM STOREFRONT WITH X" GLAZING, TYP. / MALL CONCOURSE TENANT RETAIL SPCE Pin review approval is subject to mom and orIBeIor1s. &prole! of construction documents does not authorize tilt violation of any adopted code or Otdinance. Receipt of epproved : 1 Copy ands Is acknowledged: By yGirrV /��� Deb 7- 3 - /2-- City Cf'1ikwila BUILDING DMSION NORTH NOTE: SEE SPECIFICATIONS FOR EDGE DETAIL INFORMATION 2" LONG WALL ANGLE TY II" POP RIVET * ALL MEMBERS ON WALL 8" 1 ,1 IIIIIIIIIIIIIIIU111unuIuuluuI II I II lull MAX ADA COMPLIANT THRESHOLD AND TRANSITION STRIP MALL CONCOURSE FLOOR PLAN 12' -0" LEASE LINE 1/2" = 1' -0" +12 GA. VERTICAL WIRE HORIZONTAL STRUT TYPICAL CONTINUOUS VERTICAL SEISMIC STRUT * 12 O.C. - 1 112 GA. SPLAY WIRE BRACING IN PLANE OF EACH RUNNER - VERTICAL ANGLE OF 45' (12' O.C. IN BOTH DIRECTIONS. 144 50 FT MAX) START WITHIN 4' -0" OF WALL ACOUSTICAL BOARD MAIN RUNNER OR CROSS 8" MAX Y , 111111111111111111111111111111111111111111111111 PROVIDE i" SPACE OPPOSING WALL 45° TYP 45° TYP CROSS TEE MAIN RUNNER SIESMIC BRACING DETAIL N.T.S. 4112 GA. HANGER WIRE * 4' -0" O.C. IN BOTH DIRECTIONS. ALL HANGERS AND SPLAY WIRES t0 HAVE A MIN. OF 3 TURNS IN 1" OF RUN (E) ALUMINUM SLIDING STOREFRONT WITH 3/8" GLAZING EXISTING GUJB HEADER (E) ALUMINUM STOREFRONT WITH Xi" GLAZING, TYP. LEASE LINE ADJAC SPACE NO WOF THIS AF SEPARATE PERMIT REQUIRED FOR: I$ Methanica Electrical Piumbirw Gas City of Tukwila BUILDING DIVISION ADJACENT TENANT SPACE - NO WORK NT TENANT EA L DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. DATA/ELECTRICAL/MECHANICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL, SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. NO MECHANICAL WORK ASSOCIATED WITH LANDLORD SCOPE OF WORK 3. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 4. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 5. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. 6. CONTRACTOR SHALL FURNI51-1 AND INSTALL FIRE ALARM, .SMOKE DETECTORS, AND SPRINKLERS AS REQUIRED FOR NEW TENANT SPACE MAINTAINING REQUIRED SPRINKLER AND FIRE ALARM DETECTION COVERAGE PER LOCAL JURISDICTION. I CONTRACTORS SHALL SEISMICALLY BRACE ALL FLOOR MOUNTED FIXTURES ABOVE 5' -0" IN HEIGHT PER LOCAL JURISDICTIONS. THIS ARE, LEASE WALL TYPES LINE - EXISTING (1 -HR RATED) UL i 1 WALL TYPE DESIGN • U -465 RATED -• 5/8" - METAL - 5/8" CONTRACTOR OF EXISTING 1 -HR TYPE STUD TYPE RATED X GWB FRAMING X GWB AT TENANT SPACE 51-1ALL VERIFY 114E STATUS WALL ASSEMBLY TO MEET ASSEMBLY REQUIREMENT. / NEW WALL TYPE - • . nl 6" 5 5 SINI 2 Al EXISTING ASSEMBLY UL U -465 24 G A) BOTTOM TO CONTINUE TENANT ENANT REVIEVWEDFOR CODE COMPLIANCE APPROVED JUL 0 3 2012 pU J'\ City Of V Oa BUILDING ISION - (E) 5/8" TYPE X GWB ON ADJACENT TENANT SPACE - (E) 6" METAL STUD FRAMING - (E) 5/8" TYPE X GWB - 21i" METAL STUD FURRING (MIN. AT 16" O.C. TO BOTTOM OF CEILING. 48n TYPE X GWB CONTINUE TO OF CEILING NOTE: CONTRACTOR SHALL PATCH EXISTING I- HR RATED ASSEMBLY MAINTAIN RATING PRIOR TO FURRING. FURRING AND ASSOC. GU I3 TO TO BOTTOM OF CEILING. WALL TYPE - STOREFRONT - �'' J Al " i . 5 5 • Illral \-- (E) ACOUSTICAL TILE AND GRID TO RAISED A P P R O X B 16 E \ 1 EXISTING - (E) 5/8" SPACE - (E) (E) 6" (E) 5 - (E)`srz- TYPE METAL /8 "TYPEX.GUJB E) METAL EXISTING AND GWB. PRIME, AND RATING ,ASSEMBLIES X GWB ON ADJACENT STUB FRAMING ON ADJAC WALL PANELS _ _ 6„ . . IIMII MA 7 /'\ I. CONTRACTOR SHALL VERIFY NOT LIMITED TO METAL STUD WIDTH FRAMING, CONDITION OF EXISTING 2. CONTRACTOR SHALL "PREP, TENANT SPACE TO LEVEL 4 FINISH. 4. CONTRACTOR SHALL MAINTAIN ASSEMBLIES - EXISTING AND NEW CONDITIONS, INCLUDING THICKNESS, HEIGHT OF PAINT ALL GUS WITHIN OF ALL 1 -HOUR RATED - WITHIN AREA 0 ' I (E) FAN DEMOLISHED • TO BE ti `. 1 \\ \,. !f %/ �.�` JGWB HEADER AT +/- 10' -0" f''��) �T L sPTACE Aim cc CC 100 (E)ACT 10' -4" AFF 5 5 GUJB HEAI: 4 ER 410 M i►� • / PAINT GWB SOFFIT AND HEADER = COLOR TBD RELOCATED EXISTING CEILING TILE AND GRI 5/8 "" TYPE X GLIB AT LOCATION OF NEUJ METAL STUD TRACK EXISTING METAL STUD FRAMING AND GUS TO BE DEMOLISHED Iggqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqlilqqqqqqq I®m1II MIIIlmmlIIlmlIImIICIIIDmGIODMQME MIDEIi ®nEEE L J 1. J SOFFIT HEADER EXISTING CEILING TILE AND GRID TO BE RELOCATED 16" HIGHER 1 1/2" = 1' -0" ADA COMPLIANT - THRESHOLP AND TRANSITION STRIP MALL CONCOURSE LEASE LINE (E) ALUMINUM SLIDING STOREFRONT WITH 3/8" GLAZING REVISIONS No ofchanges without 1prior as t approval of Tukwila Building Division. NOTE: Revisions WO require a new plan submittal and may include additional plan review fees. N ch: of ork itho u '1.► P. VISION hat be m Pr! f^ may .. :ude adds' e to the r ap, royal Divi ion. sal plan ' fe I_L NCOURSE FLOOR PLAN GENERAL NOTES: L DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. DATA/ELECTRICAL/MECHANICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL, SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. NO MECHANICAL WORK ASSOCIATED WITH LANDLORD SCOPE OF WORK 3. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 4. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 5. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. 6. CONTRACTOR SHALL FURNI51-1 AND INSTALL FIRE ALARM, .SMOKE DETECTORS, AND SPRINKLERS AS REQUIRED FOR NEW TENANT SPACE MAINTAINING REQUIRED SPRINKLER AND FIRE ALARM DETECTION COVERAGE PER LOCAL JURISDICTION. I CONTRACTORS SHALL SEISMICALLY BRACE ALL FLOOR MOUNTED FIXTURES ABOVE 5' -0" IN HEIGHT PER LOCAL JURISDICTIONS. WALL TYPES -- - EXISTING (1 -HR RATED) UL i 1 WALL TYPE DESIGN • U -465 RATED -• 5/8" - METAL - 5/8" CONTRACTOR OF EXISTING 1 -HR TYPE STUD TYPE RATED X GWB FRAMING X GWB AT TENANT SPACE 51-1ALL VERIFY 114E STATUS WALL ASSEMBLY TO MEET ASSEMBLY REQUIREMENT. / NEW WALL TYPE - - nl 6" SINI 2 Al EXISTING ASSEMBLY UL U -465 24 G A) BOTTOM TO CONTINUE TENANT ENANT REVIEVWEDFOR CODE COMPLIANCE APPROVED JUL 0 3 2012 pU J'\ City Of V Oa BUILDING ISION - (E) 5/8" TYPE X GWB ON ADJACENT TENANT SPACE - (E) 6" METAL STUD FRAMING - (E) 5/8" TYPE X GWB - 21i" METAL STUD FURRING (MIN. AT 16" O.C. TO BOTTOM OF CEILING. 48n TYPE X GWB CONTINUE TO OF CEILING NOTE: CONTRACTOR SHALL PATCH EXISTING I- HR RATED ASSEMBLY MAINTAIN RATING PRIOR TO FURRING. FURRING AND ASSOC. GU I3 TO TO BOTTOM OF CEILING. WALL TYPE - STOREFRONT - �'' J Al " i . Illral 3 EXISTING - (E) 5/8" SPACE - (E) (E) 6" (E) 5 - (E)`srz- TYPE METAL /8 "TYPEX.GUJB E) METAL EXISTING AND GWB. PRIME, AND RATING ,ASSEMBLIES X GWB ON ADJACENT STUB FRAMING ON ADJAC WALL PANELS _ _ 6„ IIMII '`NOTES: WALL TYPE 'GENERAL I. CONTRACTOR SHALL VERIFY NOT LIMITED TO METAL STUD WIDTH FRAMING, CONDITION OF EXISTING 2. CONTRACTOR SHALL "PREP, TENANT SPACE TO LEVEL 4 FINISH. 4. CONTRACTOR SHALL MAINTAIN ASSEMBLIES - EXISTING AND NEW CONDITIONS, INCLUDING THICKNESS, HEIGHT OF PAINT ALL GUS WITHIN OF ALL 1 -HOUR RATED - WITHIN AREA BUT STUD INCOMPLETE LTR# OF WORK o PLAN NOTES: b 1 2m...47,801 01 CONTRACTOR SHALL PREP CONCRETE SLAB FOR FUTURE FLOOR FINISHES, PROVIDING A SMOOTH LEVEL SLAB FREE OF DEFECTS. 02 EXISTING WALL ASSEMBLY TO REMAIN. CONTRACTOR SHALL PATCH, REPAIR, AND REPLACE GLUE AS REQUIRED. CONTRACTOR SHALL PREP, PRIME, AND PANT GUS - COLOR TO BE DETERMINED. 03 EXISTING 2 X 2 SUSPENDED ACOUSTICAL TILE AND GRID TO SE RAISED. GRID AND LIGHT FIXTURES 5HALL SE SEISMICALLY BRACED PER IBC 2009. GRID SHALL BE MINIMUM WITH SUPPORT GUY WIRES PER MANUFACTURES AND LOCAL JURISDICTION. SPRINKLER HEADS SHALL BE PER FIRE SPRINKLER CONTRACTOR TO BE LOCATED WITHIN CENTER OF TILES, TYPICAL - REPLACE ANY DAMAGED TILES 04 EXISTING LAY -IN 2 X 4 LIGHT FIXTURE WITHIN SUSPENDED CEILING GRID TO REMAIN. FIXTURE TYPE, QUANTITIES, AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES AND JURISDICTION. O GYPSUM WALL BOARD SOFFIT AND BULKHEAD AT TENANT STOREFRONT. CONTRACTOR SHALL PRIME, PREP, AND PAINT - COLOR MD O CONTRACTOR SHALL SECURELY ATTACHED ALL FLOOR MOUNTED CASEWORK WITH CONCRETE SCREWS (MAX Pi" LONG). CASEWORK SHALL BE SECURELY CONNECTED BACK TO WALL AT LOCATIONS WITH ADJACENT WALL ASSEMBLY. EACH UNIT SHALL BE SECURELY FASTENED TO ONE ANOTHER TO PREVENT INDEPENDENT MOVEMENT. —J 00 w J cQ F.— _9 Z LLJ W >w O� a_ M 2 N u Z U Q Q W � LU w U w 0 O 00 RECEIVED JUN 29 2012 PERMIT CENTER ISSUE Di PERMIT SET 6 -28-201 PROJECT NAME REGALIA - SOUTHCENTER SHEET TITLE: FLOOR PLAN REFLECTED CEILING PLAN AND DETIAILS SHEET NO.: A1.0