Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-224 - WESTFIELD SOUTHCENTER MALL - CELLAIRIS
CELLAIRIS 2800 SOUTHCKNTER MALL K-0981 D12-224 City #ITukwila Department of Comniuiiity Development 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.eov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Project Name: CELLAIRIS Permit Number: D12 -224 Issue Date: 07/19/2012 Permit Expires On: 01/15/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: JESSICA MAKSIMOVIC Address: 9311 E VIA DE VENTURA , SCOTTSDALE AZ 85258 Contractor: Name: Mnliv&tr<-1 sew sy 6t-rwt Address: , � Contractor License No: MA/4j °ll� Y 1� i - Lender: Name: Address: RI PIC Phone: 480 - 362 -4751 Phone: Expiration Date: 9),40 mil- MID deio3113 DESCRIPTION OF WORK: NEW KIOSK, MILLWORK ONLY, NO NEW MECHANICAL, ELECTRICAL OR PLUMBING Value of Construction: $19,000.00 Fees Collected: $748.15 Type of Fire Protection: SPRINJKLERS International Building Code Edition: 2009 Type of Construction: II -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -224 Printed: 07 -19 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied N ami with, Date: m Di I ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance o{.w;ork. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. II Date: 7 I 2 C] t Signature: Print Name: `106- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: IBC -7/10 D12 -224 Printed: 07 -19 -2012 shall not be valid. The issuance of a permit tad on construction documents and other dat ll not prevent the Building Official from requiring the correcti f errors in the construction documents and dirr data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Post address on kiosk per approved Westfield standards. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 11: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -224 Printed: 07 -19 -2012 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit N Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 9gCO Sr iC-ent-er ti46t\\ Tenant Name: l i 11011 V lS King Co Assessor's Tax No.: ,y� Suite Number: 41 14- CPO t Floor: New Tenant: [2I Yes ❑ ..No PROPERTY OWNER Name:3 erica 6 n' AG - Address: 1 311 E V1t G% Vida Name: 1„ ,Q t G1 Phone/ c-ip1) 32 -'41St FaxCNl9)`f, '01c9D--, Email tPSS1CC anpri-rl,l-)ect •rml Address:aO heer tear OA II City: - fUY—.1 / 1 l 41 t i State: a (24► 2i CONTACT PERSON - person receiving all project communication Name:3 erica 6 n' AG - Address: 1 311 E V1t G% Vida City: [Z itc Q S(atL Zip .a9s$ Phone/ c-ip1) 32 -'41St FaxCNl9)`f, '01c9D--, Email tPSS1CC anpri-rl,l-)ect •rml GENERAL CONTRACTOR INFORMATION Company Name: Architect Name: Address: 8311 E via ae voun City &O � State: A,Z Zip` SASS Address: Email: `il S. 9 CA � cori zedo. rani City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H: \Applications\Forms- Applications On Line \2011 Applications \Permit Application Revised - 8 -9 -I I.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: v P l C i% Ciro vE2 Architect Name: Address: 8311 E via ae voun City &O � State: A,Z Zip` SASS Phonerti00) '4 79 Fax: L400)4S)'019a Email: `il S. 9 CA � cori zedo. rani v ENGINEER OF RECORD Name: eel lallrls Address: l/ _0q Sh l ) oh R C3 ) 13-)00 d. Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: eel lallrls Address: l/ _0q Sh l ) oh R C3 ) 13-)00 d. / City: ik-I O,'lare State: (1'1A- Zip3ooDS Page 1 of 4 • 81JILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 10/ CVO Existing Building Valuation: $ �- Describe the scope of work (please provide detailed information): So\ e rn i 11 IA/Cr - Y10 ne w m-eCh ► Cwt 1/ C5L 1 / or plLi-Y-)10) Will there be new rack storage? ❑ Yes U:. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: U /4 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: - bel S}i MA )1 St6S rn 56 Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM N/A ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsWorms- Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 19 Floor -14.105K. N' A la SF IT 8 a 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: U /4 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: - bel S}i MA )1 St6S rn 56 Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM N/A ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsWorms- Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 -PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AUTHORIZED AGENT: Signature: Print Name: Date: Q70/ 91 / 1 SI QA (1P1X -SI 1t /) L Day Telephone: (.9 00)310a --I-751 Mailing Address: E VI 61 GU V..f lnAra H: \Applications \Forms- Applications On Line\2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh ao-i-r4ac e Piz 6 SAS$ City State Zip Page 4 of 4 • • City of Tukwila ti Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D12-224 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/29/2012 Applicant: CELLAIRIS Issue Date: Receipt No.: R12 -02158 Initials: User ID: Payee: JEM 1165 Payment Amount: $455.20 Payment Date: 07/19/2012 07:50 AM Balance: $0.00 JOSEPH A ZENKER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 075021 ACCOUNT ITEM LIST: Description 455.20 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 450.70 640.237.114 4.50 Total: $455.20 doc: Receiot -06 Printed: 07 -19 -2012 • • �J�'�"! wq� City of Tukwila C ti 1 908 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: D12 -224 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/29/2012 Applicant: CELLAIRIS Issue Date: Receipt No.: R12 -02010 Initials: User ID: TLS 1670 Payment Amount: $292.95 Payment Date: 06/29/2012 07:38 AM Balance: $455.20 Payee: joseph a zenker TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 073753 ACCOUNT ITEM LIST: Description 292.95 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 292.95 Total: $292.95 doc: Receiot -06 Printed: 06 -29 -2012 -44 INSPECTION RECORD Retain a copy with permit: INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING :DIVISION.. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ` (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Q % ,ji r i r C- (f eA l A, S Type of Inspection: E' -C ci jt 4 c %) e (A A, 6 '. Address: Date Called: - Special Instructions: Date Wanted: { ? -..":15—n.. -.( -L__ p:m. Requester: r r.= Phone /N,�ojj/�) /�l ,6. , 4 .1 Approved per applicable codes. Corrections required prior to approval.. COMMENTS: Inspector: v n REINSPECTION FEE REQUIRED. Prior to next inspection, fee.must be • paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ` :- • Date:: "_ • INSPECTION RECORD Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' (206) 431 -36 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: A / Aigl5 Type of pection: - - Ott - Ai,-- /7Ao Address: 200 Date C d: Special Instructions: Date Wanted:. ff a,m a Requester: Phone No: c-il Approved per applicable codes. COMMENTS: El Corrections required prior to approval. • f Coea:f6 Inspector: 6114 n REINSPECTION FEE REQUIRED. Prior to next inspection;; fee must be.' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule :reinspectionc_ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit n�a -aay` PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 9188 206 - 575 -4407 Project: // r. ,� C�i(1�) 12) S Ty 4e, of Inspection: t C-e- c,,d►'tom Address: A, a aw0 S ,C- M 4 1- L Suite #: j_ s71 Contact Person: ae- S9,c64 , jvl A-AS i fr ovk Special Instructions: Phone No.: Occupancy Type: _Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits:- Occupancy Type: Inspector: Date: ,g1/ it__ Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 PET tx�ti Y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -224 PROJECT NAME: CELLAIRIS DATE: 06 -29 -12 SITE ADDRESS: 2800 SOUTHCENTER MALL - K -0981 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: , Bui ding Division Pubic Works 1 ire Prevention Structural I.0kM1- q19__ Planning Division Permit Coordinator oti DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07 -03 -12 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -31 -12 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople 'ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MANAGEMENT RESOURCE SYSTEM /INC UBI No. 602918302 Phone 3368611960 Status Active Address 1907 Baker Rd License No. MANAGRS912KA Suite /Apt. License Type Construction Contractor City High Point Effective Date 4/29/2009 State NC Expiration Date 6/3/2013 Zip 27263 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date SWAIM, MICHAEL L President 04/29/2009 Amount MARION, DOUGLAS W Vice President 04/29/2009 3D05292 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 EMPLOYERS MUTUAL S377273 CASUALTY CO 04/27/2009 Until Cancelled $12,000.00 04/29/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 EMPLOYERS MUTUAL CAS CO 3D05292 04/01/2010 04/01/2013 $1,000,000.0003 /15/2012 1 EMPLOYERS MUTUAL CASUALTY CO 3D0529205 04/01/2009 04/01/2010 $1,000,000.00 04/29/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 07/19/2012 GENERAL NOTES GENERAL REQUIREMENTS A. DRAWINGS. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERT ARCHITECT TO ANY UNFORESEEN CONSTRUCTION DIFFICULTIES BEFORE BEGINNING WORK. B. PRE- CONSTRUCTION MEETING. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, THE CONTRACTOR SHALL SCHEDULE, WITH OWNERS APPROVAL, A PRE - CONSTRUCTION MEETING WITH THE LOCAL BUILDING DEPT. OR LOCAL PUBLIC WORKS DEPT. VERIFY WHICH AGENCY WOULD BE INVOLVED. THE CONTRACTOR SHALL PROVIDE LOCAL INSPECTOR WITH 24 HOURS NOTICE PRIOR TO INSPECTION. C. REPETITIVE. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL. D. CODES / PERMITS / REGULATIONS. ALL EXTERIOR SIGNAGE MUST BE SUBMITTED AND REVIEWED UNDER SEPARATE PERMIT APPLICATION. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS NECESSARY OTHER THAN THE BUILDING PERMIT. CONTRACTOR SHALL ALSO PAY FOR ALL OTHER CHARGES, FEES OR COSTS CHARGED BY THE BUILDING AND CONSTRUCTION DEPARTMENTS, UTILITY AGENCIES OR PRIVATE COMPANIES WHICH REQUIRE SUCH COSTS FOR OR PRIOR TO INSTALLATIONS. NOTHING IN THE DRAWINGS SHALL BE CONSTRUCTED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE CODES AND /OR RESTRICTIONS. SHOULD ANY CHANGE IN THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH APPLICABLE CODES AND /OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AT ONCE AND CEASE WORK. ALL PARTS PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, REGULATIONS, RESTRICTIONS, REQUIREMENTS AND CODES. • AMENDED BY GOVERNING CITY & ALL JURISDICTION RULES AND REGULATIONS. DIMENSIONS ARE SHOWN TO FACE OF MASONRY OR CENTERLINE OF OPENING, UNLESS DETAILED OTHERWISE ON DRAWINGS. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR THE EQUIPMENT FURNISHED AND INSTALLED BY HIMSELF /HERSELF OR OTHERS. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS AND ROOFS. F. SHOP DRAWINGS REVIEW. PROVIDE SHOP DRAWINGS FOR THE ARCHITECTS / OWNERS AND AS REQUIRED BY THE CITY PRIOR TO CONSTRUCTION. CONTRACTOR TO FRAME OPENINGS IN WALLS, CEILINGS AND FLOORS FOR H.V.A.C. AND OTHER MECHANICAL OR ELECTRICAL WORK WHERE REQUIRED AND NOT OTHERWISE SHOWN ON THE PLANS. H. COMPLY WITH APPLICABLE REGULATIONS FOR BARRIER -FREE FACILITIES INCLUDING: 1) MAXIMUM THRESHOLD HEIGHT TO BE ONE HALF INCH (1/2 ") ALONG ACCESSIBLE ROUTE OF TRAVEL. 2) STAIR NOSINGS TO BE FLUSH, SLIP - RESISTANT AND ROUNDED TO RADIUS OF ONE HALF INCH (1/2") MAXIMUM. FIRE PROTECTION EXTEND THE EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM AS REQUIRED. GET SYSTEM DESIGN APPROVED BY GOVERNING CITY'S BUILDING DEPT. AND FIRE DEPT. PRIOR TO INSTALLATION. (IF APPLICABLE) PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY INTERNATIONAL BUILDING CODE AND LOCATE PER FIRE MARSHALL'S DIRECTION. 1 FIRE EXTINGUISHER PER 3,000 S.F. OF BLDG. AREA WITH 75' -0" TRAVEL DISTANCE BETWEEN EXTINGUISHERS. MAINTAIN STRUCTURAL AND FIRE RESISTIVE INTEGRITY AT EXTERIOR AND RATED INTERIOR WALL PENETRATIONS FOR ELECTRICAL, MECHANICAL, PLUMBING AND COMMUNICATIONS CONDUITS, PIPED AND SIMILAR SYSTEMS PER CITY'S CODE. THERMAL /MOISTURE PROTECTION A. OPENINGS. ALL OPENING TO BE CAULKED, SEALED OR WEATHER- STRIPPED. ALL FLASHING AND ARCHITECTURAL SHEET METAL TO BE 24 GAUGE GALVANIZED STEEL, FACTORY PRIMED AND FIELD PAINTED. 10' -0" LENGTHS, PER SMACNA. MANUAL UNLESS OTHERWISE NOTED. B. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER. BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. USE POLYURETHANE SEALANTS AT CONCRETE FLOOR AND SIDEWALK JOINTS. ALL OTHER LOCATIONS USE POLYSULFIDE OR SILICONE. VAPOR BARRIERS. CONTINUOUS APPROVED VAPOR BARRIERS SHALL BE INSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED. . INSULATION. PROVIDE INSULATION PER. LOCAL CODE, COMPONENT PERFORMANCE APPROACH. 1. VERIFY IN FIELD COLUMNS EXIST. 2. CONTRACTOR TO TIMES. 3. ALL WORK MUST BE APPROVED BY BUILDING INSPECTOR PRIOR TO COVERING WORK. 4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN A WATER AND WEATHER TIGHT BUILDING. 5. ALL WORK TO BE PERFORMED TO CODE BY LICENSED CONTRACTORS PERFORMING WORK IN THEIR SPECIFIC TRADE ONLY. 6. ALL DESIGN, DRAWINGS AND DETAILS REPRESENT COMPLETE WORK IN PLACE. ARCHITECT SHALL HAVE NO CONTROL OR CHANGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION. 7. INTERIOR PARTITION DIMENSIONS NOTED ON PLANS MAY BE SHOWN A NOMINAL DIMENSION, SUCH AS 5" INTERIOR WALL REFERS TO GYPSUM BOARD EACH OVER 3 5/8" STUDS. STUD SPACING IS 24" O.C. 8. ALL DEBRIS GENERATED FROM CONSTRUCTION MUST BE KEPT ON THE SITE IN EITHER AN ENCLOSED AREA OR HAULED AWAY DAILY, AND DISPOSED OF LEGALLY OFF SITE. 9. EXTERIOR SIGNAGE IS NOT PART OF THIS CONTRACT OR PERMIT EXCEPT ELECTRICAL ROUGH -IN AND BLOCKING. SIGN CONTRACT SHALL MAKE SEPARATE SUBMITTAL TO THE CITY FOR REVIEW AND PERMIT. 10. KEEP ALL PIPING AND CONDUIT AS CLOSE TO WALLS AND ROOF DECK AS POSSIBLE AND ALL DUCTWORKS AS CLOSE TO ROOF AS POSSIBLE. WHERE EXPOSED ALL PIPING CONDUIT AND DUCTWORK SHALL BE PAINTED UNLESS NOTED. ALL PIPING AND CONDUIT SHALL BE ORGANIZED IN A NEAT MANNER RUNNING PARALLEL OR PERPENDICULAR TO ROOF FRAMING MEMBERS. 11. MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH IN FLAME SPREAD TABLE OF THE BUILDING CODE. 12. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO CONSTRUCTION AND COORDINATE WITH ARCHITECT ANY CONFLICTS WITH THE PLANS. 13. PERFORM THE REMOVAL, CUTTING AND DRILLING WITH THE CARE USE OF THE SMALLEST TOOLS SO AS TO NOT DAMAGE THE STRUCTURAL INTEGRITY OF THE BUILDING. PRIOR DEMOLITION OF EXISTING WALLS IF ANY STRUCTURAL IF SO CONTACT ARCHITECT IMMEDIATELY. MAINTAIN PROPER LIGHTING, SANITATION AND VENTILATION AT ALL KIOSK MANUFACTURER TO SUBMIT FINAL SHOP DRAWINGS TO CELLAIRIS & LANDLORD FOR FINAL REVIEW & APPROVAL. NOTE: GC TO COORDINATE WITH KIOSK SUPPLIER ALL CONNECTIONS & CONFIRM EXISTING CONDITIONS IN FIELD. VERIFICATION OF SITE CONDITIONS: TENANT IS REQUIRED TO PERFORM A SITE SURVEY OF THE ENTIRE PREMISES PRIOR TO COMPLETION OF TENANT'S CONSTRUCTION DOCUMENTS. ANY VARIANCES BETWEEN THESE APPROVED PLANS AND ACTUAL SITE CONDITIONS SHALL BE THE SOLE RESPONSIBILITY OF THE TENANT. ALL COSTS ASSOCIATED WITH REVISIONS AND CHANGE ORDERS SHALL BE THE SOLE RESPONSIBILITY OF TENANT. SCOPE OF WORK: TENANT IMPROVEMENTS FOR NEW RETAIL INTERIOR KIOSK SPACE. NO INTERIOR WALLS. NO INTERIOR CEILING. NO MECHANICAL WORK. NO PLUMBING WORK. NO SPRINKLER WORK. MINOR ELECTRICAL HOOKUP TO EXISTING FLOOR OUTLETS. SHOWCASES AND FREE- STANDING FIXTURES ONLY. SEPARATE PERIN REQUIRED FOR: /Mechanical Fleck Plumbing Gas Piping BUILDING DIVISION REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. al NOTE: Revisions will require a new plans submittal and may include additional plan review • KIOSK FOR • e m e a�r�s WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE #K0981 SEATTLE, WA 98188 Working Drawing Review Approved Approved as Noted 0 Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's Architect and/or Contractor. Tenant is responsible for complying with all government regulations. One (1) copy of this landlord stamped set of drawings is required •e kept on the job site at all times. tivie . 6.14.2012 Signed Porn* No. Plan review approval is subject to errors and omissto* Approval of construction documents does not authorize the violation of any adopt. r * s or ordinance. Receipt of approved " : • , + d ., it • is acknowledged: g ,.,:.;.; / Dat By p ?7 (ci 1L 7ti M City Of lbkwila BUILDING DIVISION s 9311 E. VIA DE VENTURA N N_ co O N N LCj CO 1- 53 ui LL. J o 07, r N u ao 0 O 8 0) a) 0 a) wa H� gLi0 Zw 0 REFERENCE SYMBOLS PROJECT DATA DOOR TAG ROOM TAG DETAIL REFERENCE REVISION 1 100 BUILDING ELEVATION REFERENCE WALL SECTION REFERENCE EQUIPMENT REFERENCE ABBREVIATIONS ACP ACT AL ALUM ARCH AVG. BLDG BLKG BR CMU CT CFM CL CLG CONC CONT CW DTL DF DIA DIM DN DR DS DWG EA ELEV EXIST or E. EXT. FDN FIN FD FL ACOUSTICAL CLG. PANEL ACOUSTICAL ,CLG. TILE ALUMINUM ALUMINUM ARCHITECTURAL AVERAGE BUILDING BLOCKING BRICK CONCRETE BLOCK CERAMIC _TILE CUBIC FEET PER MINUTE CENTER LINE CEILING CONCRETE CONTINUOUS COLD WATER DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DOWN DOOR DOWNSPOUT DRAWING EACH ELEVATION EXISTING EXTERIOR FOUNDATION FINISH FLOOR DRAIN FLOOR FLASH. FOIC FO FRP FRT GA GALV GL GWB HDWE HM HOR HT HW HWT LAV LT MAT'L MAX MTL MIN M.O. MUL N/A NIC NO. NOM NTS 0.C. OD PT FLASHING FURNISHED BY OWNER INSTALLED BY CONTRACTOR FINISH OPENING FIBERGLASS REINFORCED PANELS FIRE RETARDANT TREATED GAUGE GALVANIZED GLASS GYPSUM WALLBOARD HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HOT WATER HOT WATER TANK LAVATORY LIGHT MATERIAL MAXIMUM METAL MINIMUM MASONRY OPENING MULLION NOT APPLICABLE NOT IN THIS CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIMENSION PAINT P.LAM PLASTIC LAMINATE PLYWD PLYWOOD R RISER, RADIUS REBAR REINFORCING BAR REF REFERENCE REV REVISION RM. RMS ROOM, ROOMS RO ROUGH OPENING S & V STAIN AND VARNISH SC SOLID CORE SCHED SCHEDULE SEC SECTION SHT SHEET SPECS SPECIFICATIONS SF SQUARE FEET ST STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SS STAINLESS STEEL TB TELEPHONE MOUNTING BOARD TD TRENCH DRAIN THRESH THRESHOLD TYP TYPICAL UNFIN UNFINISHED UR URINAL VCT VINYL COMPOSITION TILE VERT VERTICAL VST VINYL SAFETY TILE W WIDTH WC WATER CLOSET WD WOOD WDW WINDOW WP WATERPROOF PROJECT NAME: KIOSK PROJECT ADDRESS: WESTFIELD SOUTHCENTER MALL 2800 SOUTHCENTER MALL SPACE #K0981 SEATTLE, WA 98188 LOCAL JURISDICTION: BUILDING & SAFETY - CITY OF TUKWILA KIOSK CODES UTILIZED: 2009 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS 2006 NATIONAL ELECTRICAL CODE W/ WASHINGTON STATE AMENDMENTS 2009 INTERNATIONAL FIRE CODE W/ WASHINGTON STATE AMENDMENTS ADAAG W/ WASHINGTON STATE AMENDMENTS 2009 WASHINGTON STATE ENERGY CODE IBC KIOSK CODE SECTION ,402.11: KIOSK AND SIMILAR STRUCTURES (TEMPORARY OR PERMANENT) SHALL MEET THE FOLLOWING REQUIREMENTS: 1. COMBUSTIBLE KIOSKS OR OTHER STRUCTURES SHALL NOT BE LOCATED WITHIN THE MALL UNLESS CONSTRUCTED OF ANY OF THE FOLLOWING MATERIALS: 1.1 FIRE- RETARDANT - TREATED WOOD COMPLYING W/ SECTION 2303.2. 1.2 ` FOAM PLASTICS HAVING A MAXIMUM HEAT RELEASE RATE NOT GREATER THAN 100kW (105Btu /h) WHEN TESTED IN ACCORDANCE W/ EXHIBIT BOOTH PROTOCOL IN UL 1975. 1.3 ALUMINUM COMPOSITE MATERIAL (ACM) HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25, SMOKE DEVELOPED INDEX OF 450 OR LESS WHEN TESTED AS AN ASSEMBLY IN THE MAX. THICKNESS INTENDED FOR USE IN ACCORDANCE W/ ASTM E 84 OR UL 723. 2. KIOSKS OR SIMILAR STRUCTURES LOCATED WITHIN THE MALL SHALL BE PROVIDED W/ APPROVED FIRE SUPPRESSION & DETECTION DEVICES. 3. THE MIN. HORIZONTAL SEPARATION BETWEEN KIOSKS OR GROUPINGS THEREOF & OTHER STRUCTURES WITHIN THE MALL SHALL BE 20'. 4. EACH KIOSK OR SIMILAR STRUCTURE OR GROUPINGS THEREOF SHALL HAVE A MAX. AREA OF 300'. MALL TYPE: 2B (FULLY SPRINKLERED NFPA13) OCCUPANCY GROUP: B TOTAL S.F.: 150 S.F. NO MODIFICATIONS TO CEILING OR SPRINKLERS. NO STRUCTURAL WORK IS TO BE PERFORMED UNDER THIS PERMIT. NO SITE WORK IS TO BE PERFORMED UNDER THIS PERMIT. (2) EMPLOYEES MAXIMUM J � J LLJ Z LlJ W I-- U z = W I- O I- O O 0 L1J O L_ O cNi W 00 00 DD 00 a) Q LiJ U LLJ Q J 0_ r (n < W REVISION PROJECT MAP CONTACT INFORMATION INDEX OF SHEETS PROJECT LOCATION TENANT INFORMATION: CELLAIRIS ATTN: SCOTT HOLCOMB 6485 SHILOH RD. BLDG B -100 ALPHARETTA, GA 30005 P: 678.513.4020 x 203 F: -- 678.341.7828 PROJECT MANAGER: NEPTUNE DESIGN GROUP ATTN: JESSICA MAKSIMOVIC 9311 E. VIA DE VENTURA SCOTTSDALE, AZ 85258 P: (480) 362.4751 F: (480) 452.0122 J ESS ICAO N EPTU N EDG. COM WWW.NEPTUNEDG.COM LANDLORD INFORMATION: WESTFIELD CORP ATTN: TIFFANY BEARD 4999 OLD ORCHARD CENTER SUITE L60 SKOKIE, IL 60077 P: (847) 779.4833 TBEARD ©WESTFIELD.COM BUILDING DEPARTMENT: CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD. #100 TUKWILA, WA 98188 P: (206) 431.3670 F: (206) 431.3665 WESTFIELD LLC ATTN: RICHARD CHUNG 2800 SOUTHCENTER MALL TUKWILA, WA 98188 P: (206) 802 -6066 RCHUNG @WESTFIELD.COM Al TITLE SHEET A1.1 GENERAL NOTES A1.2 SITE PLAN A2 KIOSK PLAN A3 A4 E1 ELEVATIONS MILLWORK DETAILS & IS IC VIEWS WIRING PLAN SECTIONS Feitigt 9 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 11 2012 1.) City of u iia BUILDING ISION NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. z24 RECEIVED JUN 29 2012 PERMIT CENTER SHEET NAME NUMBER DATED: 06.74.12 Al DISABLED ACCESS STANDARDS FLOORS & LEVELS: GROUND & FLOORS SURFACES ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE ROOMS & SPACES, INCLUDING FLOORS, WALKS, RAMPS, STAIRS, & CURB RAMPS, SHALL BE STABLE, FIRM, AND SLIP- RESISTANT, CHANGES IN LEVEL UP TOY" MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL UP TOY" &Y" SHALL BE ACCOMPLISHED BY MEANS OF A RAMP NO STEEPER THAN 1 VERTICAL TO 2 HORIZONTAL. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, IT SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION PAD OR BACKING OR NO CUSHION OR PAD; & HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT /UNCUT PILE TEXTURE. THE MAX. PILE HEIGHT SHALL BEY" EXPOSED EDGES FOR CARPET SHALL BE FASTENED TO FLOOR SURFACES & HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH SECTION 1124B.2. CORRIDORS & AISLES: 1. EVERY CORRIDOR SERVING OCCUPANT LOAD OF 10 OR MORE SHALL NOT BE LESS THAN 44" IN WIDTH. SPACE ALLOWANCES & REACH RANGES: 1. IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TO AN OBJECT, THE MAX. HIGH FORWARD REACH ALLOWED SHALL BE 48 ". SEE FIGURE 11B- 5C(a). THE MIN, LOW FORWARD REACH IS 15 ". IF THE HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH & CLEARANCES SHALL BE AS SHOWN IN FIGURE 11B- 5C(b), 2 IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR, THE MAX. HIGH SIDE REACH ALLOWED SHALL BE 54" & THE LOW SIDE REACH SHALL BE NO LESS THAN 9" ABOVE THE FLOOR AS SHOWN IN FIGURES 11B -5D(a) AND (b). IF THE SIDE REACH IS OVER AN OBSTRUCTION, THE REACH & CLEARANCES SHALL BE AS SHOWN IN FIGURE 11B- 5D(c). SPACE ALLOWANCES & REACH RANGES: 1. EMPLOYEE AREAS SHALL CONFORM TO ALL REQUIREMENTS OF THE OFFICE OF THE STATE ARCHITECT /ACCESS COMPLIANCE SECTION IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL PLUMBING CODE, & NATIONAL ELECTRICAL CODE, GENERAL REQUIREMENTS 1, EACH LIGHT OF SAFETY GLAZING MATERIAL INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A PERMANENT LABEL THAT SPECIFIES THE LABELER, AND STATES THAT SAFETY GLAZING MATERIAL HAS BEEN UTILIZED IN SUCH INSTALLATIONS, THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: A. GLAZING IN INGRESS & EGRESS DOORS EXCEPT JALOUSIES. GENERAL NOTES ALL ARCHITECTS DRAWINGS & ALL CONSTRUCTION NOTES SHALL CONFORM TO THE REQUIREMENTS OF MUNICIPAL, LOCAL OR FEDERAL AND WHETHER OR NOT SUPPLIED IN THE DRAWINGS. ALL ARCHITECT DRAWINGS & ALL CONSTRUCTION NOTES ARE COMPLEMENTARY, & WHAT IS CALLED BY ALL, ANY WORK SHOWN OR REFERRED TO ON ANY ONE SET OF DRAWINGS SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS. THE GENERAL CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERROR, INCONSISTENCY, OR OMISSION HE MAY DISCOVER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR AFTER THE START OF CONSTRUCTION, SHALL FIRST BE APPROVED BY THE ARCHITECT, STAMPED SETS OF APPROVED PLANS SHALL BE PROVIDED FOR ALL WORK. THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION, COMPLETE SETS OF STAMPED & APPROVED PLANS WITH ALL REVISIONS, ADDENDUM AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. THEY ARE TO BE UNDER THE CARE OF THE GENERAL CONTRACTOR OR HIS SUPERINTENDENT IN A LOCATION SPECIFIED BY THE LOCAL JURISDICTION. THE ARCHITECT WILL REVIEW ALL SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT OF THE PROJECT. EACH CONTRACTOR SHALL CHECK & VERIFY ALL DIMENSIONS & CONDITIONS AT THE JOB SITE RELATING TO WORK OF EACH TRADE. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF TIME DUE TO CONTRACTORS FAILURE OR NEGLIGENCE IN COMPLETELY EXAMINING THE JOBSITE. THE ARCHITECT MAKES NO GUARANTEE FOR PRODUCTS NAMED BY TRADE OR MANUFACTURE REFERENCES OF DRAWINGS IS FOR CONVENIENCE ONLY & DOES NOT LIMIT APPLICATION OF ANY DRAWING OR DETAIL DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MINOR MODIFICATIONS MAYBE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK, THE CONTRACTOR SHALL NOT BREAK SETS FOR TRADE BIDDING. ERRORS IN BIDDING AS A RESULT OF THIS PRACTICE ARE NOT THE RESPONSIBILITY OF THE OWNER OR THE ARCHITECT. THE CONTRACTOR SHALL REFER TO AND CROSS CHECK DETAILS, DIMENSIONS, NOTES & ALL REQUIREMENTS SHOWN THE ARCHITECTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE STRUCTURAL, MECHANICAL, ELECTRICAL, AND /OR CIVIL DRAWINGS, THE BUILDING PERMIT APPLICATION SHALL BE FILED BY THE OWNER /CLIENT, OR THEIR AUTHORIZED AGENT. 9, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING PERMITS & SHALL PROVIDE CERTIFICATE OF WORKMAN'S COMPENSATION INSURANCE COVERAGE. 10. THE DRAWINGS, NOTE & SCHEDULES CONVEY DESIGN INTENT. THE HIGHEST POSSIBLE QUALITY OF WORKMANSHIP, MATERIAL & EQUIPMENT SHALL BE USED 11. THE CONTRACTOR SHALL PROVIDE A LIST OF SUBCONTRACTORS, TO THE ARCHITECT & OWNER FOR REVIEW PRIOR TO SIGNING THE OWNER /CONTRACTOR AGREEMENT. 12. ALL TRADES SHALL BE THEIR OWN CUTTING, FITTING, PATCHING, ETC..., TO MAKE SEVERAL COME TOGETHER PROPERLY, AND FIT TO BE RECEIVED BY WORK OF OTHER TRADES. 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE TEMPORARY BRACING AS REQUIRED OR PORTION THEREOF DURING CONSTRUCTION. 14. CONTRACTORS SHALL INSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE REQUIREMENTS. THE MATERIAL SPECIFIED ARE INTENDED TO MEET CODE. DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS & CODE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF NEPTUNE DESIGN GROUP IMMEDIATELY BY CONTRACTOR, & PRIOR TO PERFORMANCE OF SPECIFIED WORK. 15. THE GENERAL CONTRACTOR & HIS ASSOCIATES, SUBCONTRACTORS, ETC..., MUST MAINTAIN THE SPACE, ACCESS AREAS, ETC.., CLEAN ALL TIMES & SWEEP, DUST, CLEAN, ETC.., EVERY DAY AT THE END OF WORKING HOURS. 16. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DELIVER THE JOB COMPLETELY CLEAN. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FACULTY, IMPROPER OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION & ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 18. THE SYMBOLS & ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS A QUESTION REGARDING THE DEFINITION, NEPTUNE SHALL BE NOTIFIED FOR CLARIFICATION, 19. THE CONTRACTOR SHALL SAFEGUARD THE OWNER'S PROPERTY DURING CONSTRUCTION AND SHALL REPLACE ANY DAMAGED PROPERTY OF THE OWNER TO ORIGINAL CONDITION OR BETTER. 20. THE CONTRACTOR SHALL PROVIDE ROUGH PLUMBING & FINAL HOOK -UP FOR ALL SPECIFIED FIXTURES & APPLIANCES & SHALL SUPPLY ALL SUCH FIXTURES & APPLIANCES U.N.O. 21. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION PER CITY REQUIREMENTS. THE CONTRACTOR SHALL PROTECT ADJOINING AREAS FROM NOISE, DUST, DIRT, FIRE HAZARDS. 22. THE CONTRACTOR SHALL EXERCISE DUST CONTAINMENT CONTROL TO PREVENT DIRT OR DUST FROM LEAVING THE JOBSITE. 23. ALL EXISTING MANUFACTURERS ITEMS NOT BEING REMOVED SHALL BE REFURBISHED AS REQUIRED. ANY LOOSE ITEMS TIGHTENED (INCLUDING BUT NOT LIMITED TO, EXIT SIGNS, DOWNLIGHTS, SPEAKERS, ETC.) AND MISSING PARTS REPLACED BY THE CONTRACTOR TO ACHIEVE A COMPLETE INSTALLATION WITH A NEW APPEARANCE. 24. ALL "EXISTING TO REMAIN," "EXISTING TO BE RELOCATED," AND OR NEW ITEMS INSTALLED BY THE CONTRACTOR, IN ADDITION TO BE AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION OF THE OWNER. 25. THE TENANT, WITHOUT INVALIDATING THE CONTRACT MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING TO THE WORK, THE CONTRACT SUM & CLAIMS FOR EXTENSION OF TIME SHALL BE ADJUSTED ACCORDINGLY ACCORDINGLY, SUCH WORK SHALL BE OTHERWISE EXECUTED UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT. 26. THE CONTRACTOR SHALL LEAVE THE BUILDING IN A LOCKABLE CONDITION DURING THE PERIOD OF THIS WORK WHEN THE CONTRACTOR'S WORKMEN ARE NOT PRESENT IN THE JOBSITE. 27. DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF MATCHING BUILDING LINES & LEVELS BETWEEN THE NEW & EXISTING CONSTRUCTION. 28. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES & LEVELS SHOWN ON THE DRAWINGS WITH EXISTING LEVELS FOR THE LOCATION & CONSTRUCTION OF THE WORK & SHALL NOTIFY NEPTUNE DESIGN GROUP OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 29. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HERE ON OR NOT & TO PROTECT THEM FROM DAMAGE. 30. THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE WORK, CONTRACTOR SHALL RELOCATE OR CAP OFF EXISTING UTILITY LINES AS REQUIRED, 31. ALL CONSTRUCTION SHALL BE REPLACED TO ORIGINAL CONDITION OR BETTER MATERIALS USED FOR NEW CONSTRUCTION UNLESS SPECIFIED OR INDICATED OTHERWISE, SHALL MATCH EXISTING ADJACENT MATERIALS, CONSTRUCTION AND FINISHES. 32. NO MATERIALS SHALL BE STORED IN PUBLIC PROPERTY UNLESS ENCROACHMENT PERMIT IS FIRST OBTAINED FROM LOCAL GOVERNING AGENCY. 33. THE GENERAL CONTRACTOR SHALL PROVIDE A DUMPSTER IN AN AREA DESIGNATED BY THE OWNER AND /OR PROPERTY MANAGEMENT CO. FOR THE PURPOSE OF COLLECTING TRASH & SHALL PROVIDE FOR ITS REMOVAL FROM THE SITE TO DISPOSAL SITE. ALL HOLES IN CONCRETE SLABS LEFT AFTER REMOVAL OF PIPES, CONDUITS, ETC... ARE TO BE FILLED WITH NON- SHRINKING GROUT. 34 SURFACE CRACKS & VOIDS SHALL BE TUCK POINTED OR PATCHED & ALL SURFACES TO BE FINISHED SHALL BE PREPARED IN ACCORDANCE WITH FINISH MANUFACTURER'S RECOMMENDATIONS. 35. BY ENTERING INTO AN AGREEMENT WITH THE OWNER, THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE JOBSITE, FAMILIARIZED HIMSELF WITH EXISTING CONDITIONS, & NOTED ANY DISCREPANCIES WITH THE REQUIREMENT OF THE CONTRACT DOCUMENTS. 36. BEFORE ACCEPTANCE BY THE OWNER, THE COMPLETED CONSTRUCTION SHALL BE CLEANED, LABELS REMOVED, & ALL OTHER TOUCH -UP COMPLETE. 37. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LIFE SAFETY EQUIPMENT AS REQUIRED BY STATE & LOCAL BUILDING CODES, 38. THESE DOCUMENTS INCORPORATE THE AIA GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (AIA DOCUMENT 12011) & SUPPLEMENTAL CONDITIONS PREPARED BY THE ARCHITECT, IF ANY BY REFERENCE, BIDDERS ARE REQUIRED TO BECOME FAMILIAR WITH THESE DOCUMENTS, WHICH CAN BE OBTAINED BY NEPTUNE DESIGN GROUP. 39. CONTRACTOR TO INFORM NEPTUNE DESIGN GROUP WHEN CHALKLINE LAYOUT OF PARTITIONS IS COMPLETED SO THAT IT CAN BE VERIFIED & ANY CHANGES MADE PRIOR TO CONSTRUCTION. 40. CONTRACTOR TO OBTAIN SEPARATE PERMITS FOR MECHANICAL, PLUMBING, AND ELECTRICAL WORK IF REQUIRED PER PROJECT. BUILDING NOTES MEANS OF EGRESS ALL EXIT DOORS SERVING AN OCCUPANT LOAD OF 10 OR MORE, ALONG THE PATH OF EXIT TRAVEL ANYWHERE IN A MEANS OF EGRESS SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 1003.3.1. EXIT DOORS SHALL BE OF THE PIVOTED, BALANCED OR SIDE - HINGED SWINGING TYPE, EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54LX) FROM EITHER OF TWO ELECTRIC LAMPS. INTERNALLY ILLUMINATED SIGNS SHALL PROVIDE EQUIVALENT ILLUMINANT & BE LISTED FOR THE PURPOSE, THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON -SITE GENERATOR SET, AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODE. POST A SIGN ADJACENT TO THE REQUIRED MAIN EXIT DOORS WITH 1" LETTERING STATING: "THIS DOOR MUST REMAIN IN THE FULL OPEN POSITION DURING BUSINESS HOURS." MAIN EXIT ONLY PLANS MUST INDICATE THE FLOOR OR LANDING ON EACH SIDE OF DOORS IS NOT M ORE THAN Y LOWER THAN THE THRESHOLD OD THE DOORWAY. WHEN A DOOR OPENS OVER A LANDING, THE LANDING SHALL HAVE A LENGTH OF 60" HCD & NOT BE MORE THAN Y2" BELOW THE THRESHOLD. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 11 2012 City of Tukwila BUILDING DIVISION Working Drawing Review CI Approved Approved as Noted - ❑ Resubmit These. drawings have been eV e\•aecl for general design intent only. All actual field c ondit;ons are required to be verified by the lenants Architect and' o r Contractor tenant Is responsible for complying with al! government Iegulations One i 1 } copy of this landlord stamped set of dravvings is required )e kepi on the job sto at all times. 6.14.2012 Signed Gate. biz -2.2,U RECEIVED JUN 292012 PERMIT CENTER 9311 E. VIA DE VENTURA N N O 10 ■- O a wS 0 0 EN-4 z wE5 7;0 Q Z j OU 00 LLI F-- 0) O) = W < O I-- w (r) , W1 1-1-1 O W LL O I- CO 00 00 sirmaimm (an o- (aD REVISION SHEET NAME NUMBER 6 �4..Abitea'a' "e•Wi N.E1 R 1410.4 v:lAri?RA.M3iii•,:.Agiik LEASE SPACE SCALE: 1/4" = 1' -0" EXISTING SITE PLAN (REFERENCE ONLY) SCALE: 1/64" = 1' -0" 8210 PLEASE NOTE THAT YOUR UNIT LOCATION SHOULD BE ALIGNED WITH TEH FRONT EDGE 0 TEH ADJACENT STOREFRONTS. Working Drawing Review KApproved Approved as Noted Resubmit These drawings have been reviewed for general design intent only. All actual field conditions are required to be verified by the Tenant's: Architect and /or Contractor. Tenant is responsible for complying with all government regulations, One (1) copy of this landlord stamped set of drawings is required/ eeKept on the. Job site at all times. .% 6.14.2012 37d CCs 2382ef PUBLIC CORR DOR NORDSTROM 3 LEVELS 165,900sf macys 4 LEVELS 25Q944s( 30' -10" DISTANCE TO ADJACENT STRUCTURE 30'_10„ 66'-0 - T MAUL:GBEA11ON3 DISTANCE TO ADJACENT STRUCTURE 80fING A1112 1000 I2t2 1 13201 1 3241 -3 ACUVA1E 18' -0" 38' -0' 3474T- 28 -0 01 R X9020 9021 ALK 12Osf 15Osf 1,50sf 18' --8' L_Z4•.. THIS PROJ (CELLAII 150s ill 1 1428.1 1424 24•_0• THE WALKING COMPANY 1903sf T8 -4' ......____. rt64 l' ( 8681 t fi • LUSH 650sf 3 LEVELS 272267ef STARBUCKS 843sf . C TO CONFIRM LACEMENT WITH ELLAIRIS & ON SITE ALL REP ALLEY KAT ,45018f VERIZONRELESS 2411sf sr-6P MADE IN WASHINGTON 2351 sf LOCATE EXISTI ELECTRICAL OUTLET CONFIRM WITH Fl KIOSK SUPPLI REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1 2012 64' -2 J � J LL ■ 00 LLJ 00 Z 00 TO Z�Q I 0I— W ( W ) D 0 O a_ r W LLI 0 (l) LL_ O oo W BEAUTY WORKS 20055f 112151 City of Tukwila BUILDING DIVISION 82' -B' COON MASTERCUTS 1462sf x1130) 3 LEVELS 174,6SOsf UNICONE CEP T MOBILE 1827sf 180sf CRIOWDER 140USE 86398f 660sf R -G S 1083sf T— V1013 L 1828sf G. \.C. 1080sf SEE LOCATION PLAN ATTACHED. LEADING EDGE OF CELLAIRIS KIOSK ALIGNES WITH STOREFRONT LEASE LINES OF SPACES 314 & 232 R„ \WAY COLLECT 0\ 923sf `REGALIA JEWELERS PI \ KABELLA CUPCAKES : \Us`ers \santhony \Desktop \SCR1 - 9061- OVERALL- opt5- 20120613.dwg, 6/13/2012°1:37 :29 , Adobe PDF bile-2214 RECEIVED JUN 29 2012 PERMIT CENTER REVISION SHEET NAME NUMBER • rt64 l' ( 8681 t fi • LUSH 650sf 3 LEVELS 272267ef STARBUCKS 843sf . C TO CONFIRM LACEMENT WITH ELLAIRIS & ON SITE ALL REP ALLEY KAT ,45018f VERIZONRELESS 2411sf sr-6P MADE IN WASHINGTON 2351 sf LOCATE EXISTI ELECTRICAL OUTLET CONFIRM WITH Fl KIOSK SUPPLI REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1 2012 64' -2 J � J LL ■ 00 LLJ 00 Z 00 TO Z�Q I 0I— W ( W ) D 0 O a_ r W LLI 0 (l) LL_ O oo W BEAUTY WORKS 20055f 112151 City of Tukwila BUILDING DIVISION 82' -B' COON MASTERCUTS 1462sf x1130) 3 LEVELS 174,6SOsf UNICONE CEP T MOBILE 1827sf 180sf CRIOWDER 140USE 86398f 660sf R -G S 1083sf T— V1013 L 1828sf G. \.C. 1080sf SEE LOCATION PLAN ATTACHED. LEADING EDGE OF CELLAIRIS KIOSK ALIGNES WITH STOREFRONT LEASE LINES OF SPACES 314 & 232 R„ \WAY COLLECT 0\ 923sf `REGALIA JEWELERS PI \ KABELLA CUPCAKES : \Us`ers \santhony \Desktop \SCR1 - 9061- OVERALL- opt5- 20120613.dwg, 6/13/2012°1:37 :29 , Adobe PDF bile-2214 RECEIVED JUN 29 2012 PERMIT CENTER REVISION SHEET NAME NUMBER 0 0 0 15' -0" 2' -z- " _8" 1' -0" 0" PL 2 11/A4 10/A4 SS -1 d- 1/A4 PL -2 2/A4 SS -1 SS -1 SS -1 9, -2„ PROVIDE PORTABLE FIRE EXTINGUISHER IN CABINET PER IFC L 3/A4 SS -1 4/A4 SS -1 SS -1 8/A4 SS -1 SS -1 6/A4 SS -1 9/A4 PL -2 7/A4 2'- -2n 3' -4" FLOOR PLAN SCALE: 1" = 1' -0" Cellairis material schedule SS -1 LG hi —macs Armadillo PL -1 Formica Gloss White ColorCore PL -2 Formica Gloss Black ColorCore M -1 .009 Brushed Metal Hardware Brushed silver Cabinet Interiors White PLam & White Sintra faiPadudlla ta White Slatwall NOTE: KIOSK TO BE CONSTRUCTED OF DURAFLAKE FR FIRE RATED PARTICLEBOARD. DURAFLAKE FR PARTICLEBOARD IS A UL APPROVED NON — COMBUSTIBLE MATERIAL, CLASS A /CLASS 1 —RATED FIRE RETARDANT PANEL. NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE — GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. F !ii i t _ � i r _ : i l u r �i J y � v r C i ?!1'.:E?, r .. . . - , '5i2. 2 r, .=.1 72 –.4.0,11.:'":::.':5- 4 25.0773. If' -1- i,::I: ,:err "r I. —I ,: 1r'. :.r� ri; C r':[: r +:: Frrr, H rr 1 r~ r r :- I: r aII , :.i`I :.r- tl .: I.11.!I v- IIt -'I I::rI ri::.I a Firl , 11 FiI 1: IE:�Irul:dc: I:I•r, 4ii .dl PL -2 5/A4 -2„ 1' -0" NOTE: GC SHALL COORDINATE W/ LANDLORD EXACT LOCATION OF ELECTRICAL CONNECTION FOR FINAL ELECTRICAL HOOK —UP NOTE: COUNTER NOT TO EXCEED 34" IN HEIGHT NOTE: ALL BACK ILLUMINATION TO BE LED NOTE: ALL CABINETS WHITE & BLACK FINISHES ARE REQUIRED TO BE FORMICA "COLORCORE" AS THE STANDARD. Working Drawing Review C J Approved ►%; Approved as Noted ❑ Resubmit Fhese drawings have been re iewecl for general design intent only All actual field conditions are required to be verified by the Tenants Architect andic:r Contractor Tenant is responsible for corm) {y nawith all government regulations. One 1'1 j copy of this landlord stamped set of drawings is required )e kept on the job situ at all times. 6.14.2012 signed REVIEWED FOR CODE COMPLIANCE APPROVED JUL: 1 1 2012 City of Tukwila BUILDING DIVISION Date RECEIVED JUN 2 9 2012 pERMIT CENTER 1- w w 0 Q w M 0) 00 L) 00 w —J 0 C/) F-- 0 0 0) 9 car L( ) 0 ct- w E 0 0) O a) c 0. a) J Q W 00 Z uj 00 W 1— G) CS) W Q I--- O : S o l— Cn Q J 0 O u-) �-- r (f) W CD W LL o (n I— 00 W REVISION SHEET NAME NUMBER A2 PL -2 SS -1 ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL PL -2 —PL-2 ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL 0 III eta BO C) DO M -1 M -1 — BRUSHED METAL TOEKICK ORANGE ILLUMINATED PANEL MERCHANDISE DISPLAY ELEVATION SCALE: 1 /2" = 1' -0" PL -2 PL -2 ILLUMINATED DIMENSIONAL LOGO FEATURE DISPLAY W/ LED LIGHTING SS -1 PL -1 34 MIN, 0 M -1 LBRUSHED METAL TOEKICK M -1 ILLUMINATED DIMENSIONAL LOGO ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL c2) SERVICE COUNTER ELEVATION PL -2-- PL -2 cu Co ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL FI — ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL PL -2 SS -1 M -1 — ILLUMINATED DIMENSIONAL LOGO — BRUSHED METAL TOEKICK MERCHANDISE DISPLAY ELEVATION SCALE: 1 /2" = 1 ' -0" M -1 PL- 2 PL -2 0 ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL 0 34 -r-- INTERIOR ELEVATION SCALE: 1 /2" = 1' -0" PL -2 r 34 1 NIR ILLUMINATED DIMENSIONAL LOGO INTERIOR SERVICE COUNTER ELEVATION SCALE: 1/2" = 1' -0" ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL INTERIOR ELEVATION SCALE: 1/2" = 1' -0" PL -2 34 MIN 0 PL -2 PL -2 ILLUMINATED DIMENSIONAL LOGO M -1 ILLUMINATED DIMENSIONAL LOGO ORANGE ILLUMINATED PANEL PL -2 — ORANGE ILLUMINATED PANEL '- BRUSHED METAL TOEKICK n ORANGE ILLUMINATED PANEL PL -2 O MERCHANDISE DISPLAY ELEVATION INTERIOR ELEVATION SCALE: 1 /2" = 1' -0" Cellairis material schedule SS -1 LC hi -macs Armadillo PL -1 Formica Gloss White ColorCore PL -2 Formica Gloss Black ColorCore M -1 .009 Brushed Metal Hardware Brushed silver Cabinet Interiors White PLam & White Sintra CQl1edPl id be White Slatwall Working Drawing Review Approved .I_i Approved as Noted ❑ Resubmit hese drawings have been rev'e'.ved for general design Intent only All actual fieicl conditions are required to be verified by the Tenant's Architect and /or Contractor 'tenant I5 feSpOt1Siile for cornpIyftlq with Fat government regulations. One I1:' copy of this landlord stamped set of drawings is required pe kept on the job s 'e at a?I times. 6.14.2012 signed REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1.2012 City of Tukwila BUILDING DIVISION 1/..- 21,4 Date RECEIVED JUN 292012 PERMIT CENTER NOTE: ALL BACK ILLUMINATION TO BE LED NOTE: ALL CABINETS WHITE & BLACK FINISHES ARE REQUIRED TO BE FORMICA "COLORCORE" AS THE STANDARD. NOTE: KIOSK TO BE CONSTRUCTED OF DURAFLAKE FR FIRE RATED PARTICLEBOARD. DURAFLAKE FR PARTICLEBOARD IS A UL APPROVED NON — COMBUSTIBLE MATERIAL, CLASS A /CLASS 1 —RATED FIRE RETARDANT PANEL. NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE — GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. F 1,-, 1 L i�;' t _ _ � r .e 9c....-g.- � �o r �ii -e _. f i 2.2 1'l _i ;'r:? t _ _, . f.t2..077.i -1I Ir -1.1.. I:: ,Irr °r - Firr • 11 11 1 I' I: r :. I:- i .1 _ .Iii.. -.1; .1 :r I _ I.1:.t :.1 L., II f n. :11 :.i-i .J- tl I_II.,l r -I It a L` :rrli _I :1 Frrl • II.. c•�rrr :d:1 t; Firr. II•. ,It'd 1. 1:t ' .tc,.1 f ., �� li _ILI I.i•r , i -i 111 li:i rti. : :r. .1 9311 E. VIA DE VENTURA N SV 9 r0 00 P 480- 362 -4481 E 0 a) 0 Q I-- zc) w LLI I-- U z = LLJ I— CD 0 I-- C) O OCT) LLl 0 LL-0 I— 00 C LiJ 00 00 00 0) Q CD LI LLI 0_ I- C) Q LLJ Cr) 0 REVISION SHEET NAME NUMBER 84 ___7IN CELLAIRIS LOGO 34 228 584 TOWER & -,-0 U 1 SAME FOR ITEM 5.0 ORANGE ACRYLIC WHITE DIFFUSER ON BACK \--T5 LIGHT TO UT ACRYLIC PANEL LED STRIP UNDER SHELVES SPACE BEHIND ADJACENT CABINET __3 IN SKIRT ON ADJACENT CABINET KICK BASE 1/8 BLACK REVEAL ON SKIRT _ —__7IN CELLAIRIS LOGO 34 22a 11i 84 584 14 CONDO TOWER SCALE Jr -1'-0 1 12 2 50 12 574 1/8 BLACK REVEAL ON SKIRT SPACE BEHIND ADJACENT CABINET ORANGE ACRYLIC ___..._—_.WHITE DIFFUSER ON BACK T5 LIGHT TO IJT ACRYLIC PANEL 12 66 L TOWER END SCALE: Jr - J 3 IN SKIRT ORANGE ACRYUC WHITE DIFFUSER ON BACK 34 T5 UGHT TO LIT 'ACRYUC PANEL LED STRIP UNDER SHELVES SPACE BEHIND ADJACENT CABINET SITS ON ADJACENT CABINET KICK BASE LED STRIP UNDER SHELVES CONDO DISPLAY 28 46 72 69 EXTERIOR FINISH GLOSS WHITE CC INTERIOR WHITE MELAMINE .___1/8" BLACK REVEAL ON SKIRT 1/2" RABBET FOR GLASS 32 14 STADIUM TOWER SITS HERE SCALE: 1i• - P -o" STADIUM / ) SCALE - 96 EXTERIOR FINISH GLOSS WHITE CC 1/4" TEMPERED GLASS LIGHT SUDE GLASS DOORS STADIUM DISPLAY STORAGE 34 J LED STRIP TOE KICK ILUMINATION _INTERIOR WHITE MELAMINE 1/8" BLACK REVEAL ON SKIRT 1/2" RABBET FOR GLASS 1/4" TEMPERED GLASS T8 LIGHT SUDE GLASS DOORS 271 32 2 STADIUM DISPLAY 93 20 4 172 X 77 96 172 77 66 40 54 14 SLOTWALL /STADIUM / SCALE: 11 - 1 -A" ( 1 0) STORAGE LED STRIP TOE KICK ILUMINA11ON 1/2" RABBET FOR GLASS 1/4" TEMPERED GLASS T8 LIGHT SHOWCASE SUDE GLASS DOORS 37 SLOTWALL DISPLAY STADIUM DISPLAY STORAGE 34 J LED STRIP TOE KICK ILUMINA11ON 28 24 4' 4 16 4 34 i 64 0 1 0 20 14 1 40 POS lSCALE X" 26 0 G 46 SLOTWALL /FEATURE DISPLAY f -7'\ sAALe 7ri - EXTERIOR FINISH GLOSS WHITE CC 161N 3D LOGO _1/8" BLACE REVEAL ILLUMINATED BRUSHED ALUMINUM TOE KICK 24 T5 LIGHT TO UT LOGO 23 ACCESS FOR WIRING LED STRIP TO LIT TOEKICK WIRE CHASE FEATURE DISPLAY WITH PUCK UGHTS LED STRIP ON SIDES AND TOP SUDE GLASS DOOR SPACE BEHIND ADJACENT CABINET ORANGE ACRYLIC ____WHITE DIFFUSER ON BACK T5 UGHT TO UT ACRYUC PANEL 12 TOWER END SCALE: 11i - 1'-C" LED TOE KICK FOR ILLUMINATION BRUSHED ALUMINUM TOE KICK FACE REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1 2012 City of Tukwila BUILDING DIVISION LED STRIP UNDER SHELVES CONDO DISPLAY FEATURE DISPLAY ON TOP__. 12 1411 34 48 FEATURE - 1•-o_ 4 DISPLAY `~ TEMPERED 3/8" GLASS LET PUCK UGHT SUDE GLASS DOOR 222 21116 LET STRIPS SIDES AND TOP LED STRIP FOR TOE KICK ILLUMINATION Working Drawing Review ❑_ Approved 1_! Approved as Noted 0 Resubmit These drawings 'lave been 'eV;E. /eCI for general design Intent billy. All actual fled co ditsons a e required to he verified 's- )y the Tenant s Architect ancUcr Contractor tenant is responsible for complying vvith al] government regulations. One 11 i copy of this landlord stamped set of drawings is required he kept on the job sste at all tinges. signed 6.14.2012 Date.' EXTERIOR GLOSS WHITE CC INTERIOR WHITE MELAMINE 1/8" BLACK REVEAL BRUSHED ALUMINUM FINISH 1/2° RABBET FOR GLASS T8 UGHT SUDE GLASS DOOR STADIUM DISPLAY STORAGE 1/8" BLACK REVEAL SCALE:1j' - LED STRIP TOE KICK ILLUMINATION RECEIVED JUN 2 9 2012 PERMIT CENTER Cellairis material schedule SS -1 LG hi —macs Armadillo PL-1 Formica Gloss White ColorCore PL -2 Formica Gloss Black ColorCore M -1 .009 Brushed Metal Hardware Brushed silver Cabinet Interiors White PLam & White Sintra Cal kid War White Slatwall NOTE: KIOSK TO BE CONSTRUCTED OF DURAFLAKE FR FIRE RATED PARTICLEBOARD. DURAFLAKE FR PARTICLEBOARD IS A UL APPROVED NON— COMBUSTIBLE MATERIAL, CLASS A /CLASS 1 —RATED FIRE RETARDANT PANEL. NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. Finn )C: ?! s .oriro • _!l f Ir -1- i. 1 i• -I 1� : I q -i. r I:I :I;�I+ : ' Fii r, 11. it I r 'r:: r : I r °I.r :t:. <a l: , n f I i.::.11 ,I 1 .j- tl ,: (_ n: r r -I It -',1 I. ,I1 rl..1_1:r Firs . 117• Firf llc Jr .i i �:r.. t:cl f IE.LII - =itic I:I•', ,'i -I 111 rl 1-: r .:r• .I P 480 -362- Q W 7 W W I--- U Z = W U O 1- O 0 Cn J W U LL O F— CJ (f) CSI W 00 00 00 Cr) <t LL.] U C)< (W L! ! REVISION SHEET NAME NUMBER A4 Working Drawing Review ❑ Approved J =+;" Approved as Noted ❑ Resubmit These drawings have been reviewed for general design Intent only. ;\H actual `laid conditions are required to be verified by the Tenant s A.rc'hItect and(cr Contractor Tenant Is r _:,sponslhle fear ,:oriptying with ail goveinrnent regulations. One l t't copy of this landlord stan'pcd set of dl'a.vings is rrngl.riredr: kept on the job site at all times. 6.14.2012 Signed Date. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 1 2012 City of Tukwila BUILDING DIVISION ISOMETRIC VIEW 1 SCALE: 1" = 1' -0" Cellairis material schedule SS -1 LG hi —macs Armadillo PL -1 Formica Gloss White ColorCore PL -2 Formica Gloss Black ColorCore M -1 .009 Brushed Metal Hardware Brushed silver Cabinet Interiors White PLam Sc White Sintra taddkidlb sa White Slatwall NOTE: KIOSK TO BE CONSTRUCTED OF DURAFLAKE FR FIRE RATED PARTICLEBOARD. DURAFLAKE FR PARTICLEBOARD IS A UL APPROVED NON — COMBUSTIBLE MATERIAL, CLASS A /CLASS 1 —RATED FIRE RETARDANT PANEL. NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE — GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. Fin f5.1 2.275 . 572 ?..,. ,111 . ;r- r+ u 1 i ,err r i. -1. " Fier . II tr l r r I , -L 1'; 111. -1, :r,. :.I :r -a! :-r :ar .. ;,r.l )- tl .: I.n.•r r.l it- :r I. .rrri :. :._1 :r Fn r : II-. :41.:r.1 by Fir r. II: ,rr• :1 is rite ; :,;. : #c.i t; _t F.Ii__ILI haR, :11 ISOMETRIC VIEW 2 SCALE: 1" = 1'-0" RECEIVED JUN 2 9 2012 PERMIT CENTER REVISION SHEET NAME NUMBER A5 T5 T5 T5 T5 T5 T5 NOTE: ALL WIRING SHALL BE MC AND INSTALLED PER UL ASSEMBLY. GC TO MAKE FINAL CONNECTION OF PLUG TO EXISTING MALL OUTLET - GC TO CONFIRM LOCATION WITH LL [5] T5 T5 600 W OUTLET FOR POS NEMA 5 -15P GENERAL RECEPTACLE T5 T5 T5 PROVIDE CAT 5 & PHONE DATA - GC TO CONFIRM CONNECTION LOCATION OF LIGHT SWITCH [5] 15 WIRING PLAN SCALE: 1 " = 1 ° -0" NOTE: KIOSK TO BE CONSTRUCTED OF DURAFLAKE FR FIRE RATED PARTICLEBOARD. DURAFLAKE FR PARTICLEBOARD IS A UL APPROVED NON - COMBUSTIBLE MATERIAL, CLASS A /CLASS 1 -RATED FIRE RETARDANT PANEL. NOTE: ALL EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING TO REMAIN. NO NEW MECHANICAL, ELECTRICAL, AND PLUMBING WORK TO BE DONE - GC TO COMPLETE FINAL ELECTRICAL CONNECTION AT EXISTING OUTLET PROVIDED BY LANDLORD. Finn 7 rk'eS,w pr>r k i� l• "l!?ii ��f.'i �II .r -rr•1 it 71 1..:L:I .rl r ..r - i. -I : I .r :r -i. I r,a: -r +; : Firr . 11. it 1 r r; r , 1 =1 III. .- r .all ,r: r 1 : r.J:.t::1 Ls ii r ,ar :. 4.1:1 .,. r tl .: I_n. I r -r lt-rr I: rrli:.:.r:r. Fn r . IL III Frrr. Ile are 'Ill TYPICAL CONNECTIONS OF LED LIGHTS NOTE: GC SHALL COORDINATE W/ LANDLORD EXACT LOCATION OF ELECTRICAL CONNECTION FOR FINAL ELECTRICAL HOOK -UP (GC TO VERIFY IN HELD & COORDINATE WITH FINN PRIOR TO SHIPPING OF KIOSK) Working Drawing Review El Approved in: Approved as Noted ❑ Resubmit These drawings have been '.'e'viev:'ea for general design Intent only. /\Ii actual filed conditions are required to be verified by the 'f enants .Architect and/or Contractor tenant is r sponsible for cort?laiyinrg with all government regulations. One (1) copy of this landlord stamped set of drawings is required tyLbe kept on the job site at rail times. 6.14.2012 Signed Date RECEIVED JUN 292012 PERMIT CalTER NOTE: ALL BACK ILLUMINATION BE LED TOTAL LOA CIRCUIT BR • 900 WATT 7.5 AVP 1_-_-AKER: 2°4 REQ. \OTE: ALL WR\G S-ALL BE I\STALLED PER UL ASSEVBLY. \OTE: \0 PA \EL IS REQUIRED. GC TO COPLETE HNAL ELECTRICAL CO \ \ECTIO\ AT EXISTING FLOOR OUTLET PROVIDE) BY LAVDLO u+ N :1:1Z 0 do w N U c� co CIL O U 0) a) 0 a) z,� =w < E-- 0 I— LLJ cn LLi0 w IL o I-- 00 (f) N LLJ o L.. oamisrum co limmosimmem (10) REVISION SHEET NAME NUMBER