Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D12-239 - BIG LOTS - TENANT IMPROVEMENT
BIG LOTS 173�I S SOUTHCENTER PY D12-239 City o"Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 3523049005 Address: 17348 SOUTHCENTER PY TUICW Suite No: Project Name: BIG LOTS Permit Number: D12-239 Issue Date: 08/22/2012 Permit Expires On: 03/26/2013 Owner: Name: KIR TUKWILA 050 LLC /KIMCO Address: PROPERTY TAX DEPARTMENT , 3333 NEW HYDE PARK STE 100 11042 Contact Person: Name: LAUREL WALYGA Address: 379 CAMPUS DR, STE 150 , SOMERSET NJ 08873 Contractor: Name: BOBBY CASTLE CONSTRUCTION Address: 3874 LIMMER LOOP , HUTTO TX 78634 Contractor License No: BOBBYCC088PT Lender: Name: Address: Phone: 732 667 -9500 Phone: 512 846 -1998 Expiration Date: 11/02/2012 DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENT OF EXISTING RETAIL SPACE Value of Construction: $250,000.00 Fees Collected: $4,475.01 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -239 Printed: 10 -03 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: 1/U 12 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDPITONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State doc: IBC -7/10 D12 -239 Printed: 10 -03 -2012 of Washington. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IF'C 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC doc: IBC -7/10 D12 -239 Printed: 10 -03 -2012 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. t Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance No. 2327). 34: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2328. 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 40: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinlder head deflectors in sprinldered areas of buildings. (IFC 315.2.1) 41: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. doc: IBC -7/10 D12 -239 Printed: 10 -03 -2012 (NFPA 13- 12.3.1.13) • • 42: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 43: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 44: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 45: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 46: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -239 Printed: 10 -03 -2012 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049005 Address: Suite No: DEVELOPMENT PERMIT +MI6 SOUTHCENTER PY TUKW 119-11) Project Name: BIG LO Permit Number: D12-239 Issue Date: 08/22/2012 Permit Expires On: 02/18/2013 Owner: Name: KIR TUKWILA OSO LLC /KIMCO Address: PROPERTY TAX DEPARTMENT , 3333 NEW HYDE PARK STE 100 11042 Contact Person: Name: LAUREL WALYGA Address: 379 CAMPUS DR, STE 150 , SOMERSET NJ 08873 Contractor: Name: BOBBY CASTLE CONSTRUCTION Address: 3874 LIMMER LOOP , HUTTO TX 78634 Contractor License No: BOBBYCC088PT Lender: Name: Address: Phone: 732 667 -9500 Phone: 512 846 -1998 Expiration Date: 11/02/2012 DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENT OF EXISTING RETAIL SPACE Value of Construction: $250,000.00 Fees Collected: $4,475.01 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: UB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -239 Printed: 08 -22 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: :ta‘' Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ���� " Date: Print Name: l C C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State doc: IBC -7/10 D12-239 Printed: 08 -22 -2012 of Washington. • • 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC doc: IBC -7/10 D12 -239 Printed: 08 -22 -2012 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mrn) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinlders shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 34: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2328. 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 40: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 41: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. doc: IBC -7/10 D12 -239 Printed: 08 -22 -2012 (NFPA 13- 12.3.1.13) • 42: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 43: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 44: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 45: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 46: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -239 Printed: 08 -22 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, W4 98188 http: / /www.TukwilaWA.aov Building Perm Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION t 1; Site Address: SouthCenter Parkway- Parkway Supercentei Suite Number: Floor: 1 King Co Assessor's Tax No.: 352304 -9005 Tenant Name: Big Lots PROPERTY OWNER Name: Laurel Walyga Name: Kimco City: Somerset State: NJ Zip: 08873 Address: 17600 Southcenter Blvd Email: lwalyga @core - eng.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Laurel Walyga Address: 379 Campus Drive, Suite 150 City: Somerset State: NJ Zip: 08873 Phone: (732) 667 -9500 Fax: (732) 667 -9501 Email: lwalyga @core - eng.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: WD Partners City: State: Zip: Architect Name: John Miologos Address: Address: 7007 Discovery Blvd City: Dublin State: OH City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:AApplications \Forms - Applications On LneA2011 Applications A Permit Application Revised - 3-0.11 docx Revised. August 2011 bh New Tenant: m Yes ❑ ..No ARCHITECT OF RECORD Name: Company Name: WD Partners City: State: Zip: Architect Name: John Miologos Address: 7007 Discovery Blvd City: Dublin State: OH Zip: 43017 Phone: (614) 634 -7000 Fax: Email: ENGINEER OF RECORD Name: Company Name: WD Partners City: State: Zip: Engineer Name: Sam Khalilieh Address: 7007 Discovery Blvd City: Dublin State: OH Zip: 43017 Phone: (614) 634 -7000 Fax: Email: LENDER/BOND ISSUED (required for projects 55,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION —206-431-3670 Valuation of Project (contractor's bid price): $ 250,000 Describe the scope of work (please provide detailed information): Tenant Fit Out of existing retail space. Will there be new rack storage? Yes Existing Building Valuation: $ 25,365,400 ❑ .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure Nexs Type of Construction per IBC Type of Occupancy per IBC 1st Floor 27,497 27,497 11 -B M 2' Floor 3`a Floor. doors- _ thru: Basement Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives i one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard:6X( . \r.. SAS) r pact: Handicap: Will there be a change in use? ❑ Yes ® No if "yes ", explain: Floor area of accessory dwelling: FIRE PROTECTION /HAZARDOUS MATERIALS:(,ntr( I S)■tt • 1` ri AL -. mt.) Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 21 No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a.current septic design approved by King County Health Department. H: \Applications \Forms - Applications On Line \2011 Applications \Permit Application Revised - 8- 9-11.docs Revised: August 2111 • bh Page2of4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued. within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: AGEN • Print Name: Laurel Walyga Mailing Address: 379 Campus Drive, Suite 150 H: \Applications \Forttts - Applications On Line \2011 Applications \Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Date: 07/10/2012 Day Telephone: (732) 667 -9500 Somerset NJ 08873 City State Zip Page4of4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3523049005 Permit Number: D12-239 Address: 17686 SOUTHCENTER PY TUICW Status: APPROVED Suite No: Applied Date: 07/18/2012 Applicant: BIG LOTS Issue Date: Receipt No.: R12 -02424 Payment Amount: $2,713.90 Initials: WER Payment Date: 08/22/2012 03:18 PM User ID: 1655 Balance: $0.00 Payee: BOBBY CASTLE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 36989 2,713.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $2,713.90 2,709.40 4.50 doe: Receipt -06 Printed: 08 -22 -2012 City of Tukwila, 1 Department of Community Development 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: /Avww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R12 -02150 Initials: JEM Payment Date: 07/18/2012 User ID: 1165 Total Payment: 2,163.29 Payee: WD PARTNERS SET ID: S000001778 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D12 -239 D12 -240 EL12 -0671 M12 -111 TOTAL: 1,761.11 292.95 55.37 53.86 1,761.11 TRANSACTION LIST: Type Method Description Amount Payment Check 77868 2,163.29 TOTAL: 2,163.29 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 55.37 2,107.92 2,163.29 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 -Permit inspection Request Line (206) 431 -2451 Project:,) r �-.— ` Lc (r Type(bf Inspection: ( k.1, `.0 ( k b , / Af/ r)".' IN Address: r:') 34 :y' .5 c--b t(44 Date Called: -\ = --., Special_ Instructions: ( Date Wanted:. d J..3 iv �a.m? p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Date: 0 REINSPECTION "FEE REQUIRED. Prior to next inspection. fee must be paid :at.6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD. Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431= 3670 Permit Inspection Request Line (206) 431 -2451 t�t�2=Z3Cs Project: c-, Laic Type of Inspection: Cnt_i\ ZtNIC�.._' Address: Date Called: Special Instructions: /I"' Date Wanted:. 1O-3cD-17 .p.m.. Requester: Phone No: 7t)e. - '7 el- t* 7 Approved per applicable codes. E3Corrections required: prior to approval. COMMENTS: JJ) St Ls ,\AG, /1 A-M_< ^('-> A Date: 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - • INSPECTION RECORD .Retain a copy with permit '.INSPECTION NO PERMIT NO. CITY OF TUKKWILA BUILDING DIVISION C 6300Soutlicenter °B1vd:; #100, Tukwila. WA 98188 tz, (206) 431 -3670 Permit InspectionRequest Line (206) 431 -2451 1.x)2 - 2- 3C Project`' (3' H LC..� S Type of Inspection: r v1A4n c. fA,ct'i L.;c.., L. f€ c) Address :' .-- .' 77:71.(;-...8 .00e spV Date Called: Speciarinstructions: Date Wanted: . `p r2. -12. a.m. lam;. Requester: Phone No: -Approvedperapplicable codes. Corrections required prior to approval. COMMENTS: . • Inspecto r\__ Date: n REINSPECTION'FEE REQUIRED. Prior to next inspection. fee must be . paid.'at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTIIN NO. PERMIT NO. CITY OF TUKWILA BUILDING .DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Id:.. (206)431 3670 Permit Inspection Request Line (206) 431 -2451 Project: r r� 'r Type o .Inspection: .S aspend Date Called: ') 1 - A Addrej i 31-X Sc 0,41"ka1Ay Special Instructions: 1 I : . Date Wanted: 1 0J .. -- a .m. , *:ri. Requester: Phone No: O Approved per applicable codes. El Corrections required prior to approval: :r. COMMENTS: K G 7 - 1 6- -v :. oDi r Inspect r: LL iVi �, n REINSPECTION FEE REQUIRED. Prior to next inspection fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule' reinspection.7 Date: E' C. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 0 Permit Inspection Request Line (206) 431 -2451 VG- Project: .276 WC1%3 _ Type of Inspection:_, X5'2 ,s, 0 C7Tt.T%G Address: /734/6 So l'' /r / Date Called: e."-J 1/4.J Er Special Instructions: Date Wanted:. 9- 27-/Z. <am? p.m. Requester: Phone No: .:Zo�376- /.x37 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: _ - ---t ) }J ae—g --S D i . 4-(e.f e."-J 1/4.J Er • (E0 / e ems : - -f te_.: i 600 ,�. % 1 Insp or: )1 11 A Date: e` l n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ' I ti INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Z. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 df Project: T i if R /1,4/) ),,i G- I -p (3,41t/�' J 5 t i b 1 ;0-i -/ a Type of Inspection: (7-) r>Ct?c k(4\ 04t/.e40 /./ Address:. D Act-t -r t t -4 Date Called: Special Instructions: D Date Wanted:. a a.m. Requester: Phone No: Approved -per. applicable codes. ElCorrections required prior to approval Z COMMENTS: P A i if R /1,4/) ),,i G- I -p (3,41t/�' J 5 t i b 1 ;0-i -/ a E 1<'(.'`11/ i e o ) (7-) r>Ct?c k(4\ 04t/.e40 /./ lart,irl ;)y4 CIS c ?,A 4 -6 ty, ( o\,,o vd) (A); ; i F-5 V . Inspectio"?t REINSPECTION FEE REQUIRED. Prior to fiext inspection, fee must be (,a(d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Dat , /_ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit is) // -03? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: i4 C-�e�► -� ov �S -- of Insp ,ion: '� ( - Hood & Duct: 100 Address: /Liz, Suite #: .des Contact Person: Special Instruct'ioris: Phone No.: .ke Approved per 'applicable codes. Corrections required prior to approval. COMMENTS: c--)K Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: . Pre -Fire: Permits: ' Occupancy Type: Inspector: /A\ Avi-A S c)- Date: /6 //6. )/ 2_ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 47/2 - z 37 is -s• 7/i PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: 6.,• y /0.t- s ,C,* Type of Inspection: C..... �- J//- r sio r.el./4i 4 • Address: / 7 3-1-i& Suite #: s c "Ci-vr Contact Person: Special Instructions: Pre -Fire: Phone No.: ,Xf Approved per applicable codes. Corrections required prior to approval. COMMENTS: ( / Ca(l'ecf'..,✓/9 CH .1ii,Y/,? /7.070.0/.e-. Needs Shift Inspection: ,C,* Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor: \ Pre -Fire: Permits: Occupancy Type: Inspector: ,C,* S,) Date: /'! //e /i2_ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain 'a copy with permit / —2.79 /gip -�•�_ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -57.5 4407> 4 ,_„ Project: 4, !��s \, Type of Inspection: _ /e. /6421.a� ii .) I ;,�4 Address: /7 384 8° Suite #: s c fi le- w- ' Contact Person: 5 ,01.,�, "-re-,e.._ Q re. 3 r-,),-, DG /hoc .rc.L lag Special Instructions: r. ` Phone No.: / a 2 s-3 — 3 7 ca / 3 3 5— 1 Approved per applicable'codes. Corrections required prior to approval. COMMENTS: % \, Ia.4 04 5:5J)4- °I.0 0 4dd•e-ss.o4v.' /.4 -fa L./L. 577.97-. - 2 7 / O A11' %sT o 1( 5,01e )L-,- dcle-, .1d,, ✓4b44,,- F;44•' a/‘' ; Q re. 3 r-,),-, DG /hoc .rc.L lag 0 e, y , S.✓Y, Ale re clF"%*e��`d /S NA. .� 0 & 44 -Po c'/< � LJ J d�c1✓/S • /t(. " • C. ,ic1,e Ica S o/< /7 At 11 S*c..*,'v..,, S 4r /< g) ,Ob'sCode.t _ 0 f X'%' r� .,Si/z.vbe-s S, - ( d e >< / ) 4, 60 X /Se) ■•< ` . 0 Parr ) ea-4+e 1/4-Jh-5 2G• S"- ' 0 fg F 444,Gea. -J iee5�1 --- 12 3 V T` ' /�'i �✓JcI o- �i•��,S /3� s 29.S2Y,s a3.; Z3.s- A y7e_ doc.,ZA Aiese--/- '` 4- :S Y. ,'/. 5,—,ze * ~ — P4 _ /�^��- 'L ' 4ddi—e- ss, ja i/Ay 717 _,,Uc„,i U . A d Needs Shift Inspection: Sprinklers.,_ Date: a ?/i Fire Alarm:" Hrs.: ; Hood & Duct: : 7 .� Monitor: ,' Pre-Fire: b °'"' Permits: % Occupancy Type: - ` . Inspector:. F1)9$3 Date: a ?/i j•/ & < Hrs.: 4 $100.00 REINSPECTION FEE REQUIRED. You will receive an` invoice from the City -,of Tukwila Finance Department. Call to schedule a reinspection. Billing Address, Attn: Company Name: Address: r_ City: Word /Inspection Record Form.Doc State: Zip: T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER l� -s- a 6, O/d- ,239 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: 2i J04- 5 Sprinklers: Type of Inspection: S� Address: 1 3 L/ S . C Suite #: &i4j Contact Person: Special Instructions: � L Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: L /., Co4wy, Lef & o. / I r+e rl n N 6,- - ,n)k ) -e -7-17,,,,i_ Is' s A- 1 `'A-c PiR AS . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: &/ c /_ Date: / D0 l Z Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Instructions for Electronic Forms 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Intro Chapters 11 -15 of the 2009 Washington State Energy Code apply to all nonresidential occupancies and to all multifamily residential occupancies except those within the scope of the IRC (single family residential, duplexes, attached townhouses). This file, LTG09.XLS, has electronic compliance forms for Chapter 15 (lighting system, motors, and transformers). There are three companion templates to this file: MTR09.XLS (Chapter 12 metering requirements); ENV09. velope requirements); MECH09.XLS (Chapter 14 mechanical systems requirements. This form is a compliance aid and is not a substitute for the full energy code text or specific uidiction•compliance requirements. Users should refer to the code text and contact the local jurisdiction for complete information. The full 2009 WSEC code text is available for download from: Download 2009 WSEC from htto: //www.neec.net/sites /default/files /neec codes/WA- EneravCodes2009.odf Start -up Open a working copy of this file and be sure to use Save As to save it to a new file name. Alternatively, you can save the file as a template in the XLSTART subdirectory in the EXCEL directory, and open new copies with the "File New' menu command. Look for "LTG09'. Overview This workbook file contains multiple worksheets. Each worksheet is indicated by a tab at the bottom of the screen. (If you don't see the tabs, visit menu option 'Tools-Options-View-Sheet Tabs ".) You may visit each form by clicking on its tab. Most calculations are automated. The spaces which display the results of calculations are not editable. Some adjustments to formatting have been made to facilitate electronic filling and calculation of the forms. Save Files Each time you open this file and start filling forms, you must save it under a new filename of your choosing using File Save As. The original template file cannot be altered. You may also save your own versions of the forms this way. Getting Around Each form has two pages (front and back). Both pages are available on screen when you click the tab for a form. Use the scroll bars to find the second page. It is either to the right, below, or sometimes to the right and below the first page. Filling Fields All project info and the date for all forms is entered once on "PRJ- SUM" and automatically reproduced on the other forms. Always fill in the heading of PRJ-SUM, even if you will not be using that form. The other forms have a reminder to do this. Only fillable fields are accessible. If you try to edit any other field, you'll get an error message. You may use the TAB key to move to the next tillable field. If the TAB doesn't take you where you want to go, use the mouse. Avoid excessively long text strings when entering information. In some cases, text that extends beyond the available space will simply not be seen. In most cases, the text will wrap within the cell. This may force part of the form onto a new page To enter the date, use this format: mm/dd/yyyy. For example, you would enter 7/1/2006 or 12/15/2007. Check bones can be either blank, or checked -off with an X shown in the box. To toggle between cases, click the box with your mouse. Radio buttons (circles) are either filled or unfilled. Only one in a set may be filled. Drop -down lists have an arrow at the right side of the space. Click the arrow with your mouse and select the appropriate option. One of the options is a blank. When a form has a space for notes or explanation, click anywhere in the space to edit. Your cursor will become a text editing insertion bar and you can edit as with a word processor. Personal- izing You can personalize the forms with your company name, address, phone, or any other information. This is done by editing the footer using File Page Setup Header/Footer. You can then save the file under a new template name and re-use it again. Adding Lines and Removing Many tables, such as for listing equipment types, have a certain number of lines for entering data. There may not always be enough lines for all the entries you need to make. With this electronic version, you can add additional lines to the table. To add additional lines where this feature is available, click on the " +' button with your mouse. This button is located to the right of the sheet. If you can't see it, scroll right (or change the View Zoom setting to 83 %). To remove lines that you have added, click on the button with your mouse. You cannot remove lines that were not added; an error appears it you try. If you add additional lines with this method, the pagination will usually be affected. The forms will be forced to carry additional lines over to other pages. Be sure to submit all pages to the plans examiner. Printing The forms should print on any printer supported by W indows. You will need to have the follaving TrueType fonts installed under Windows: Arial, Times New Roman, Courtier New and Wingdings. These are all standard Windows fonts. If you are losing form or flowchart details when printing, you may have a shortage of printer memory. Try printing problem pages individually. By default, only selected forms are printed. To select me or more forms, hold down the Ctrl key and click the tabs of the worksheets you need. Issue the File Print Selected Sheets command. To print the entire set, use File Print Entire W orkbodc Clean Forms It is possible to print clean, blank versions of these forms for,hand filling. To do so, delete all of the heading information at the beginning of PRJ-SUM, and make sure that all fillable cells in the forms are empty. Then print the clean forms. For each radio button group, there is a button labeled "Clear". Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear' button will not print. Partial Form Sets Forms in a workbook may not be deleted, because the file is locked, B3but you need not print all the forms, as explained in "Printing' above. Re -Calcu lation As this is a large file, it may respond slowly to changes if it is set to automatically re-calculate after every action. To set calculation to manual, visit the "Tools- Options - Calculation" menu item. Then manually recalculate using the F9 key. kecopr REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 0 2012 City of Tukwila BUILDING DIVISION CITY OF TUKWItA JUL 18 2012 PERMIT CENTER Pt231 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential PRJ -SUM Revised December 2010 Project Info Project Address /6 Lo,.T 5 - �AQIcWAy Svi:RCEN _re 2 Date % /r> /12 / '7 6 e& Sewn. C.c.-ere/2- 7 A2J ,f For Building Department Use MkwrLa, wA 98/88 Applicant Name: s,a Leis S1- ,2e5 /Nc. , Applicant Address: -300 PrnLLI P / Po. Cotapfivs, 6N 43228 Applicant Phone: (9 /4 - 278 - 66tr, 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Li • • i • 2009 Washington Sta a Energy Code Compliance Fors for Nonresidential and Multifamily Residential Allowed Watts per ft2** Revised December 2010 Project Info Project Address/ 3,6 /475_ Ptk+�M Sk�EKCEr`+TE2 Date ?i5�/z /768e Sok,»•r+C &I-TEX fht2(awu/ For Building Department Use Tvkw'L' 1 WA 98188 Applicant Name: P16 L,oi5 5 -TbrES wc. Applicant Address: Sao PwI /1 'P/ RD Cp(,,,,,,,84.,, , pp 143228 Applicant Phone: , /14_278- to Soo Project Description • New Building • Addition Ili Alteration • Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Aretysis (See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plants.) Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting and space use not changed • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. 1 Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2** cross ntenor Area in ft2 Allowed x Area 5A Les 1RE`r.4,L /.33 2'7,q'rT 36,5'71 .5AL S £/to" fLuxR.Escem -r SRRIP S Nt3 N0N -s l- ' 5 S =o" FLuogE- se,,. -r s-rF2 r o 3 5 9 6 able 15 -1 (over) - document all exceptions on form LTGLPA Proposed Lighting Wattage Total Allowed Watts Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 5A Les Sod" FLUORESCENT s-rRtP 2'714 % 24›,3014 38c1 .5AL S £/to" fLuxR.Escem -r SRRIP S Nt3 N0N -s l- ' 5 S =o" FLuogE- se,,. -r s-rF2 r o 3 5 9 6 3,, 360 A90w+ -SAGEr q f O" FL vog.s ,-T STI= -r F Z. if $ 1 otal Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Wattsl30 44 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, Tamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of ct rent limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt fighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Prescriptive Spaces Occupancy 0 Warehouse or Parking Garage • Other Qualification Checklist Note: r occupancy type is "Other" and fixture answer is checked. the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. 1 not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 • Check if 95% or more of fixttes comply with 12 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T-5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <=150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' - - LPA (W/ft`) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group I -3 Occupancies 0.90 Cafeterias, fast food establishments 5, restaurants/bars 5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retal10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft 2 with full height partitions, a Unit Lighting Power Allowance of 1.1 IN/ft 2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by wells or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply. i. 0.6 watts per square foot of sales floor area not listed in items it and it below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or ill. 2.5 watts per square foot of jewelry, crystal or china floor area The specified floor area for items i, ii, or li above, and the adjoining circulatlon paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance Is the sum of allowances for sales categories I, 1, or it plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fbdures with two points of tract attachment). This additional lighting power is allowed only if the fighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the fighting is actually installed. 11) Provided that a fbor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Exterior Lighting Summary LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Resid Project Info ProjAddres 0;6 Lors - fix kwAy S pErL�7&z. Date ry 5fcz _ __- ..w�. �V'V 176,84 Sov- trice,- P�•tzr. Pi For Building Department Use -1-5 k v�,LA ; t &1A 98/89 Name: 4 Lois 57ofZES. 1 NC Apps. Name [- um, sell. c'�c,,nnf3„S, oN 413228 Apps. Phone apt- 2' 8_6Svo Project Description • New • Addition ud Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Lighting Zone (as specified by Jurisdiction) O Zone 1 Zone 2 0 Zone 3 0 zone 4 Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) • Efficacy> 60 Iumens/W • Controlled by motion sensor • Exemption (list) Alteration Exceptions • No changes are being made to the lighting and space use not changed. (check appropriate box - sec. 1132.3) • Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Base Site Allowance:I Tradable Surfaces Description Anowea watts per ft2 or per If Area (ft`), perimeter (If) or # of items Allowea warts x ft2 (or x If) Total Allowed Tradable Watts: T-._�_L7_ Tv__ ____i r !_.t.• ._ - ••• .. ge (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total proposed tradable watts may not exceed the sun of total allowed tradable watts plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Tradable Watts: Base Site Allowance Remaining: Non- Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (nor # of items Allowed Watts x ft2 (or x if) on- raaanle Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non- tradable surfaces are less than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Exterior Lighting Summary (back) LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B LIGHTING POWER DENSITIES FOR BUILDING Revised December 2010 Specific area description Zone 1 500 W Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' Tradable Surfaces z " - Uncovered Parkin g g Parking lots and drives Areas z 0.04 W/ft2 z 0.06 W/ft2 z 0.10 W/ft2 0.13 W/ft2 Building Grounds Walkways less than 10 ft wide 0.7 W /linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W/ft2 0.14 W /ftz 0.16 W /ft2 02 W /ft2 Exterior Stairways 0.75 W /ftz 1.0 W /ft2 1.0 W/ft2 1.0 W/f12 Pedestrian tunnel 0.15 W /ft2 0.15 W/ft2 0.2 W/ft2 0.3 W/ft2 Landscaping 0.04 W/ft2 0.05 W/ft2 0.05 W/ft2 0.05 W/ft2 Building Entrances and Exits Main entries 20 W/linear foot of door width 20 W/linear foot of door width 30 W/linear foot of door width 30 W/linear foot of door width Other doors 20 W/linear foot of door width 20 W/linear foot of door width 20 W/linear foot of door width 20 W/linear foot of door width Entry canopies 0.25 W/ft2 0.25 W /ftz 0.4 W/ft2 0.4 W /ftz Sales Canopies Free standing and attached 0.6 W/ft 0.6 W /ft2 0.8 W /ft2 1.0 W /ft2 Outdoor Sales Open areas3 0.25 W /ft2 0.25 W /ft2 0.5 W /ft2 0.7 W/ft2 Street frontage for vehicle sales lots in addition to "open area allowance No Allowance 10 W/linear foot 10 W/linear foot 30 W/linear foot Non- Tradable Surfaces° Building Facades No Allowance 0.1 W/ft2 for each illuminated wall or surfaces 0.15 W/ft2 for each illuminated wall or surface6 0.2 W/ft2 for each illuminated wall or surface Automated teller machines and night depositories 270 W per locations 270 W per locations 270 W per locations 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W /ft2 of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles - 0.5 W/ft2 of covered & uncovered area Material handling and associated storage No Allowance' No Allowance INo Allowance, 0.5 W/ft2 Drive -up Windows & Doors 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry FOOTNOTES FOR TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales Tots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be trade between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted i the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting Power Allowance Adjustments 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address J !Date c o.yr CEO-7 L ThRktv/: f - T k. w 'LA , A 9�/r LTG -LPA Revised December 2010 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior fighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG SUM. Adjusted Lighting Power Allowances (Interior Location (floor plan/room #) Occupancy Description Allowed Watts per ft2'* Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Wad per ft2 ase• on exceptions listed in footnotes , 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential • • , • • • • • rmer - ermi • ans ec ist LTG -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address /,,6 �Co Ve Cr,,-re fair - rok_g,rca, tt1Q 98/88 Date 1 i7///2- The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) j Code I Section r Component 'Information Required Location on Plans' Building Department Notes LIGHTING CONTROLS (Section 1513 yes 1513.1 Local controVaccess Schedule with type, indicate locations A - 3 YES 1513.2 Area controls Maximum limit per switch Lc -q Yes 1513.3 Daylight zone control Schedule with type and features, indicate locations NIA vertical glazing Indicate vertical glazing on plans A overhead glazing Indicate overhead glazing on plans - IJ 14- 1513.4 Display /exhib/special Indicate separate controls - yES 1513.5 Exterior shut -off Schedule with type and features, indicate Location e.--y Ye, (a) timerw/backup Indicate location E_y 165 (b) photocell. Indicate location yes 1513.6 Inter. auto shut -off Indicate location C, y /C.3 1513.6.1 (a) occup. sensors Schedule with type and locations e--9 NIA 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans _ IV l rk 1513.7 Hotel /motel controls Indicate location of room master controls N I 4. 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) y e5 1514 Max watts Indicate watts for each exit sign IA- 3 LIGHTING POWER ALLOWANCE (Section 1530 -1532) N /e5 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture A- -3 I1532 /VA- Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency M -2_ TRANSFORMERS (Section 1540) r •if b I 1540 ITransformers 'Indicate size and efficiency 1 ., I y question, provide explanation: �vJ1LA�' • tiZ Gity f Tukwila of o July 27, 2012 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Laurel Walyga 379 Campus Dr, Suite 150 Somerset, NJ 08873 RE: Correction Letter #1 Development Permit Application Number D12 -239 Big Lots —17686 Southcenter Py Dear Ms. Walyga, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, "14::).ctg Bill Rambo Permit Technician encl File No. D12 -239 W:\Pennit Center \Correction Letters \2012 \D12 -239 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: July 24, 2012 Project Name: Big Lots Permit #: D12 -239 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized . format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Calculations for the plumbing fixtures shown are not consistent with current Washington State Amendments (WSA) for required plumbing fixtures. Per the square footage shown 20604/200 =52, "M" group 2 required for 51 -100. Office "B" occ. 747/200 =4, "B" group 1 required for 1 -15. Storage area 4886/500 =10, "S" group 1 required for 1 -10. Therefore 4 fixtures for each male and female bathroom are required. Three toilet fixtures each are shown; one additional fixture each shall be required. Please revise plan and calculations to show an additional bathroom toilet fixture. Revise calculations for bathroom fixtures on the cover sheet. (IBC TABLE 2902.1 WSA) 2. Provide an egress plan. Egress plan shall specifically show the common path of egress travel with minimum 36 inch wide accessible paths of egress, that lead to each emergency exit. Show travel distance, with dimensions, measured from the most remote point along the unobstructed path of egress travel to an exterior exit door. (IBC 1014.3, 1016.1) 3. Common paths of egress shall be provided with emergency illumination. Emergency illumination shall have at least an average 1 foot - candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Coordinate with the egress plan to show emergency illumination shall be located over the designated egress paths indicated in item # 2. (IBC Section 1006 & 1008.1.6) Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. PARTNERS o r o r O r r o M 0 o 0 cc cc o CC gt m � 7. > o o • o CO _z ✓ J O CO O 0 O WDPARTNERS.COM REVISION 1 Big Lots Tukwila, WA WD Partners Job Number: BLTRF0126 Date: August 7, 2012 To: Tukwila Building Division Department of Community Development 6300 South Cen Tukwila, WA 98188 USA Attn : Allen Johannessen RE: Correction Letter #1 Development Permit Application Number D12 -239 Big Lots- 17686 South Center Parkway The following letter is in response to comments, to the above referenced project, generated by your office on July 24, 2012. This letter serves to summarize the revisions to the Construction Documents in response to these comments. All changes to the Construction Documents have been clouded as Rev #1. 1. Calculations for the plumbing fixtures shown are not consistent with current Washington State Amendments (WSA) for required plumbing fixtures. 4 fixtures for each male and felmale bathroom are required. 1.01 T -1: Calculations for required plumbing fixtures were updated. 1.02 A -1: Addtional restroom fixtures were added. 1.03 A -1: A fixture mounting height schedule was included. 1.04 P -1: Plumbing drawings and specifications were added. 1.05 M -1: Added keyed note 10 for clarification of exhaust duct connections. 1.06 M -1: Added supply and exhaust air to the new restrooms. 1.07 M -1: Reduced the drum diffuser airflow for the additional air being provided to the new restrooms. 1.08 M -2: Updated the Air Balance Schedule for the new restrooms. 1.09 M -2: Updated the Air Distribution Device Schedule for the exhaust grilles in the new restrooms. 1.10 M -2: Updated the Exhaust Fan Schedule for the addition of the new restrooms. 1.11 M -2: Updated the Ventilation Schedule for the addition of the new restrooms. 2. Provide an egress plan. Egress plan shall specifically show the common path of egress travel with minimum 36 wide accessible paths of egress that lead to each emergency exit. Show travel distance, with dimensions, measured from the most remote point along the unobstructed path of egress travel to an exterior exit door. 2.01 T -2: An egress plan was added to the set. This plan shows common paths of egress at each exit as well as the travel distance from the most remote point in the building. REVISION 1 1 TUKWILA, WA Page 1 of 2 • 3. Common paths of egress shall be provided with emergency illumination. Emergency illumination shall have at least an average 1 foot - candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Coordinate with the egress plan to show emergency illumination shall be located over the designated egress paths indicated in item #2. 3.01 A -3: Egress/ Exit discharge lighting notes were added to the sheet. 3.02 T -2: Emergency lighting has been coordinated to be located over the common paths of egress. Should you have questions or need additional information, please feel free to contact me, Janell Arehart, directly at 614- 634 -7353. END OF REVISION Cc: REVISION 1 1 TUKWILA, WA Page 2 of 2 143ERMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -239 PROJECT NAME: BIG LOTS SITE ADDRESS: 17 V1SOUTHCENTER PY DATE: 08/14/12 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPART ENTS: ii9,01 B n Division Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 71 Incomplete ❑ DUE DATE: 08/16/12 Not Applicable ❑ Comments: Permit Center Use Only . • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ REVIEWER'S INIT ALS: DATE: No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 09/13/12 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use OnIy CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 12 Ping ❑ PW ❑ Staff Initials: ERNlIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -239 PROJECT NAME: BIG LOTS DATE: 07/18/12 SITE ADDRESS: 17686 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EPAR MENT Nk 01 • ( Public Works () 4,,, AG1C a, IP bl l ' e Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07/19/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route JJ Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 08/16/12 Not Approved (attach comments) DATE: Permit Center Use Only /�/j� CORRECTION LETTER MAILED: vl v Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D12-239 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued erglitelVED r] Revision requested by a City Building Inspector or Plans Examiner (►//(q NV 14 ?072, Project Name: Big Lots rEliMlrCEM'EA Project Address: 17686 Southcenter Py Contact Person: LaUSC Phone Number: X32' Summary of Revision: i 1t� i.n QS (\CIt9esk Sheet Number(s): 7-110 1 P i v l - 1 I I -a 7-) 114-3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ;� Entered in Permits Plus on \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOBBY CASTLE CONSTRUCTION 5128461998 3874 Limmer Loop Hutto TX 78634 Out Of State Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601417166 Active BOBBYCC088PT Construction Contractor 10/30/1992 11/2/2012 General Unused Business Owner Information Name Rote Effective Date Expiration Date CASTLE, BOBBY Owner 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929157225 11/02/2004 Until Cancelled $12,000.00 10/11/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 18 CONTINENTAL INS C2080000270 11/02/2008 11/02/2012 $1,000,000.00 11 /04/2011 17 CONTINENTAL CASUALTY CO TCP2080000270 11/02/2006 11/02/2008 $1,000,000.00 10 /29/2007 16 TRANSCONTINENTAL INS CO TCP2080000270 11 /02/2005 11/02/2006 $1,000,000.00 11 /03/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 08/22/2012 BIG LOTS STORES, INC. NNING DEPT. 300 PHILLIPI PLA ROAD LOTS COLUMBUS, OHIO 43228 � PHONE: (614) 278 -6800 MATERIALS AND EQUIPMENT SCHEDULE Product Supplied by Installed by Manufacturer & Model Number Vendor and Contact Information Floor Tile (Sales, Offices, Lounge, Restrooms) BIG LOTS BIG LOTS GC Azrock V -862 Tom Kelly Flooring 904 - 398 -0225 Floor Tile (Vestibule, Restroom Entry) BIG LOTS BIG LOTS GC Azrock SR -120 Tom Kelly Flooring 904 -398 -0225 Ceiling Tile BIG LOTS BIG LOTS GC Certaineed BET197 Tom Kelly Flooring 904 -398 -0225 Storefront Doors BIG LOTS GC BIG LOTS GC GT 1175 Nabco 877-622-2694 or Stanley 303- 623 -5539 or 888 - 366 -7444 Stockroom Doors BIG LOTS BIG LOTS GC Chase - SRP -5000 w/ 5 "x9" Jamb Gurds (Black) Chase - Christine Smith 513 - 603 -2904 Baby Changing Table BIG LOTS BIG LOTS GC DIAPER -DEPOT MODEL #4300 - OVAL BABY CHANGING STATION Safe Strap Co. Jennifer Hippley 800-356-7796 EXT: 238 Toilet Seat Cover Dispenser BIG LOTS BIG LOTS GC Krystal KD -100 w/ mounting tape Blackhawk - Mike Kroeplin 877 - 296 -0908 Air Nester Dispenser BIG LOTS BIG LOTS GC Timemist 32 -1131 Blackhawk - Mike Kroeplin 877 - 296 -0908 Paper Towel Dispenser(At mop sink) BIG LOTS BIG LOTS GC Stefco 91004 Blackhawk - Mike Kroeplin 877- 296 -0908 Soap Dispenser BIG LOTS BIG LOTS GC GoJo FMX -20 Black Blackhawk - Mike Kroeplin 877- 296 -0908 Toilet Paper Dispenser BIG LOTS BIG LOTS GC Stefco 93000 Blackhawk - Mtke Kroeplin 877 - 296 -0908 Electric Hand Dryers BIG LOTS GC BIG LOTS GC Xlerator XL -W George Scott & Assc. 888- 611 -9711 Restroom Partitions BIG LOTS GC BIG LOTS GC Typical - Powder coated metal - Light gray in color Optional Energy Management System BIG LOTS BIG LOTS GC Site Controls 512- 306 -9400 Cord Reels w/ T -grid brackets BIG LOTS BIG LOTS GC Alemite 7260 John Pulliam 704- 904 -9615 Lamp Wall Plugmold BIG LOTS BIG LOTS GC Big Lots Kit - Available from Loeb Electrical Chuck Sibio -Loeb Electric 614 -421 -3346 Watt Stopper Light Switches BIG LOTS BIG LOTS GC Leviton ODS10 - IDW City Lighting 412 - 366 -7009 Dock Light (if required) BIG LOTS BIG LOTS GC Technical Consumers Products Head Dock Light, Part #LDLI6WSY01 TCP Lamp - 15W, Spot Beam Type, Part# LEDDL15 Arm - Dock Light Arm Part #LDA42 /LDACC1 Chuck Sibio -Loeb Electric 614 - 421 -3346 Strip Light (8' fixture) BIG LOTS BIG LOTS GC Metalux #8TSSF- 232- UNV- OS- QHE4X32T8UNVISNSG -U City Lighting 412- 366 -7009 Strip Light (4' fixture) BIG LOTS BIG LOTS GC Metalux #SSF- 232- OS- QHE2X32T8UNVISNSC -U City Lighting 412- 366 -7009 Strip Light (Emergency) BIG LOTS BIG LOTS GC Metalux #8TSSF- 232- 120v- OS- EL- FBP240H- OSQHE4X32T8UNVISNSC -U City Lighting 412- 366 -7009 Strip Light (Lamp) BIG LOTS BIG LOTS GC Sylvania #SLY F028/841 XP /SS /ECO City Lighting 412 -366 -7009 Emergency Exit Red LED Sign BIG LOTS BIG LOTS GC Technical Consumers Products TCP 22743 City Lighting 412- 366 -7009 Remote Head Emergency Light BIG LOTS BIG LOTS GC Technical Consumers Products TCP 207R4 City Lighting 412 - 366 -7009 Track Light {8` track) BIG LOTS BIG LOTS GC 8' Single Circuit White Track - Part # L652 -P City Lighting 412 -366 -7009 Track Light (4' track) BIG LOTS BIG LOTS GC 4' Single Circuit White Track - Part # L651 -P City Lighting 412- 366 -7009 Track Light (track parts) BIG LOTS BIG LOTS GC Live End Feed White - Part # L901 -P City Lighting 412 -366 -7009 Track Light (Head @ Jumbo Tron) BIG LOTS BIG LOTS GC 32W LED Flood, Type TH1 CNTRV34 -32- LED- E- WT -TN1- 120 -FL -4000 City Lighting 412- 366 -7009 CODE INFORMATION 1. APPLICABLE CODES: BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: FIRE: ACCESSIBILITY: ENERGY: 2009 INTERNATIONAL BUILDING CODE, WAC CH. 51 -50 STATE BUILDING CODE ADOPTION & AMENDMENTS 2009 INTERNATIONAL MECHANICAL CODE, WAC CH. 51 -52 STATE BUILDING CODE ADOPTION & AMENDMENTS 2009 UNIFORM PLUMBING CODE, WAC CH. 51 -56,& 51 -57 STATE BUILDING CODE ADOPTION & AMENDMENTS 2006 NATIONAL ELECTRIC CODE, WAC 296 -46b STATE BUILDING CODE ADOPTION AND AMENDMENTS 2009 INTERNATIONAL FIRE CODE, WAC CH. 51 -54 STATE BUILDING CODE ADOPTION AND AMENDMENTS ADAAG, WAC CH. 51-40 2003 ICC/A117.1 ACCESSIBILITY CODE 2009 WASHINGTON STATE ENERGY CODE, WAC CH. 51 -11 2. BUILDING DESCRIPTION: BUILDING TYPE: CONSTRUCTION TYPE: USE GROUP: EXITS PROVIDED: EXISTING HEIGHT: STORE ADDRESS: BIG LOTS STORE # PARKWAY SUPERCENTER 17686 SOUTHCENTER PARKWAY TUKWILA, WA 98188 SITE PLAN Oita Cosmetics Thai Mali Wrap 0 Roil `Cold Stone Crean SEPARATE PERMIT REQUIRED FOR: ki Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION Permit No. Plan review approval is abject to was and omissior+a. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved l j and =eons now d sd: By City Of TUkwiia BUILDING DIVISION EXISTING RETAIL SPAC. II -B (EXISTING) MERCHANTILE - M 3 1 STORY - 40' -0" MAX. FIRE SPRINKLERS PROVIDED: EXISTING TO REMAIN ALLOWABLE AREA: 12,500 SPRINKLER INCREASE: 12,500 x 300% PER 506.3 = 50,000 SF 3. BUILDING AREA: SALES (FURNITURE SALES 2,415) OFFICES /LOUNGE STORAGE /S H I P P I NG /JAN /E LEC RESTROOMS GROSS TOTAL AREA 20,604 747 4,898 347 27,497 4. OCCUPANT LOAD: MERCHANTILE 20,604 SF / 30 SF PER PERSON: BUSINESS: 747 SF / 100 SF PER PERSON: STORAGE AREAS: 4,898 SF / 300 SF PER PERSON: TOTAL CALCULATED OCCUPANCY REQUIRED EGRESS WIDTH 712 x 0.2 INCHES /OCC. = PROVIDED EGRESS WIDTH DOOR #2 = DOOR #9 = DOOR #10 = TOTAL CALCULATED WIDTH 5. PLUMBING FIXTURE OCC LOAD: OCCUPANT LOAD BASED ON TABLE 2902.1 687 (M) MERCHANTILE 8 20,604 SF/200 SF PER PERSON: 103.0 = 52 OCC./ EACH SEX 17 (8) BUSINESS: 747 SF / 200 SF PER PERSON: 712 = 2 OCC./ EACH SEX (S -1) STORAGE AREAS: 4,898 SF / 5000 SF PER PERSON: = 1 OCC./ EACH SEX 143" 72" 36" 48" 156" TOTAL 3.7 0.9 MEN WOMEN TOILET 1 LAV 1 TOILET ILAV 1 1 1 1 1 0 1 0 4 2 4 2 6. PLUMBING FIXTURES REQUIRED (M) MECHANTILE/BUSINESS: TOILETS: FEMALE 1:1 -50, 2:51 -100, 3:101 -200 TOILETS: MALE 1:1 -50, 2:51 -100, 2:101 -400 LAVATORIES: 1 PER EVERY 2 TOILETS EACH SEX (B) BUSINESS: TOILETS: FEMALE 1:1 -15 TOILETS: MALE 1:1 -15 LAVATORIES: 1 PER EVERY 2 TOILETS EACH SEX (S) STOCK ROOM: TOILETS: FEMALE 1:1 -10 TOILETS: MALE 1:1 -10 LAVATORIES: 1 PER EVERY 40 OCCUPANTS EACH SEX 7. PLUMBING FIXTURES PROVIDED MEN'S RESTROOM: TOILETS: 2 LAVATORIES: 2 URINALS: 1 WOMEN'S RESTROOM: TOILETS: 3 LAVATORIES: 2 SCOPE OF WORK REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 0 2012 City of Tu' I$a BUILDING !SION ARCHITECT /ENGINEER Ami 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM DRAWING PAGE AND TITLE ARCHITECTURAL • D -1 • A -1 • A -1.1 • A -2 • A -3 • FP -1 DEMO PLAN CONSTRUCTION PLAN CONSTRUCTION NOTES FIXTURE PLAN LIGHTING PLAN FIRE ALARM PLAN ELECTRICAL • E -1 • E -2 • E -3 • E -4 ELECTRICAL PLAN ELECTRICAL NOTES EMS NOTES EMS SPECIFICATIONS MECHANICAL • M -1 • M -2 MECHANICAL PLAN MECHANICAL NOTES • MINOR INTERIOR TENANT IMPROVEMENTS AND ALTERATIONS TO THE EXISTING BIG BOX RETAIL LEASE SPACE TO ACCOMMODATE A NEW BIG BOX RETAIL TENANT. NO CHANGE TO OCCUPANCY TYPE, INCREASE IN OCCUPANT LOAD, OR AREA ARE PLANNED UNDER THIS PERMIT. • IMPROVEMENTS TO THE EXTERIOR OF THE BUILDING ARE LIMITED TO A MINOR BRAND ELEMENTS. ALL NEW SIGNS SHALL BE SUBMITTED UNDER SEPARATE PERMIT APPLICATION. • EXISTING RESTROOM PLUMBING FIXTURES ARE TO REMAIN AS EXISTING. ANY NEW ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH THE ACCESSIBILITY REQUIREMENTS. • COORDINATION AND /OR INSTALLATION OF MECHANICAL SYSTEM DESIGN IS PART OF THE PROJECT SCOPE. • ALL HVAC UNITS ARE EXISTING. ANY REQUIRED MODIFICATIONS TO THE STRUCTURE DUE TO CHANGES MADE TO THE EXISTING UNITS WILL BE DONE BY THE LANDLORD AND SHALL BE THE UNDER SEPARATE PERMIT SUBMITTAL AND APPROVAL. NOTE: ANY MODIFICATIONS TO THE EXISTING FIRE ALARM OR SPRINKLER SYSTEMS SHALL BE SUBMITTED BY A LOCALLY LICENSED FIRE SUPPRESSION SYSTEMS CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO ANY WORK BEGINNING ON THESE SYSTEMS. SPRINKLER SYSTEM SHALL BE TESTED AND IN COMPLIANCE WITH NFPA -13 UPON COMPLETION OF THIS PROJECT REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittI and may include additional plan rev?e,v fn:,. CORRECTION LTR #�.}.� DEVELOPMENT CONTACTS DEPARTMENT OF COMMUNITY DEVELOPMENT: BILL 6300 SOUTH CENTER BOULEVARD, SUITE 100 TUKWILLA, WA 98188 206- 431 -3670 ISSUE DATES CLIENT REVIEW PERMIT BID REVISION 1 CONSTRUCTION 07-01-2012 07 -05 -2012 07 -05 -2012 08 -07 -2012 08-10 -2012 12-2:31 • WD PROJECT NUMBER BLTRF0126 i CITY s: CI 1 Y OF T tiii,\J AUG 1 42012 PERMIT CENTEF. 62 TITLE PAGE AUG 07'O12 9 byt11O1... .11. :''J rOF WASHilGT Oil "! T -1 EXIT #4 (stock room) 36" PROVIDED = 180 OCC BUILDING DESCRIPTION: BUILDING TYPE: CONSTRUCTION TYPE: USE GROUP: EXITS PROVIDED: EXISTING HEIGHT: EXISTING RETAIL SPACE II-B (EXISTING) MERCHANTILE - M 3 1 STORY - 40' -0" MAX. FIRE SPRINKLERS PROVIDED: EXISTING TO REMAIN ALLOWABLE AREA: 12,500 SPRINKLER INCREASE: 12,500 x 300% PER 506.3 = 50,000 SF Note to city inspectors: The yellow hi- lighted /clouded path is the portion of the egress system that is required to be tested to confirm compliance with section 1006.4 IBC. 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot - candle and a minimum at any point of 0.1 foot - candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ration of 40 to 1 shall not be exceeded. BUILDING AREA: SALES (FURNITURE SALES 2,415) OFFICES/LOUNGE STORAGE/SHIPPING /JAN/ELEC RESTROOMS GROSS TOTAL AREA 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot-candle at the waNung surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings... for exit discharge doorways... 20,604 747 4,898 347 27,497 OCCUPANT LOAD: MERCHANTILE 20,604 SF / 30 SF PER PERSON: 687 BUSINESS: 747 SF / 100 SF PER PERSON: STORAGE AREAS: 4,898 SF/300 SF PER PERSON: TOTAL CALCULATED OCCUPANCY 8 17 REQUIRED EGRESS WIDTH 712 x 0.2 INCHES /OCC. = PROVIDED EGRESS WIDTH DOOR #2 = DOOR #9 = DOOR #10 = TOTAL CALCULATED WIDTH 712 143" 72" 36" 48" 156" 12`174--S1 EXIT #5 (sales floor) 36" PROVIDED = 180 OCC 16' -9" COMMON PATH OF TRAVEL @ 5-0" SPRINKLER RISER ECTRIC 101 -0" COMMON PATH OF TRAVEL @ 5' -O" EXIT #1 (sales area) 60" PROVIDED = 300 OCC Mid 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDRARTNERS. COM ISSUE DATES CLIENT REVIEW PERMIT ###11:#1##V# BID ##41#144#4t#44 CONSTRUCTION WD PROJECT NUMBER 6266 REGISTE' 0111.-4 ti 1.00 STATE 0 A INGTON z 0 U) w ce w r;i 1WI z q STOCKROOM 4,898 SqFt FURNITURE DEPARTMENT 2,323 SqFt cc Q i IZ ZEt W u N- W WO =a Ci) ma -H 4, NEW RESTROOMS FURNITURE I FURNITURE RACKING RACKING FURNITURE FURNITURE RACKING RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE FURNIT RACKING RAC 26' -5" COMMON PATH OF TRAVEL @ 5' -6" FURNITURE RACKING FURNITURE RACKING REVIEWED FOR CODE COMPLIANCE APPROVED AUG 202012 City of Tukwila BUILDING DIVISION 55' -0" COMMON PATH OF TRAVEL @ 5' -0" NVdS3GIM LOUNGE MANAGER COUNT OFFICE EXIT #3 (stock room) 60" PROVIDED = 300 OCC 225' -0" PATH OF TRAVEL cc z z D 0 lZGl.r'IV� CITY CF TUKV, `- AUG 1.4 2012 TEFL SQUARE a w 0 w O 1- CO Z ce 0 CV f/0 0 W J av TOTAL: w 1 0 0 II N co cO Ua N Z0 ,1.o WzQ - coo OzcON, < :C0T o w I W JCCa.DZ 0 00 0 I �I�cnMUfa_ EXIT #2 (sales area) 36" PROVIDED = 180 OCC SHEET: EGRESS PLAN II II II JL II I II II 11 I II II I II li 1 11 II L —JL JL - -- I 11 i 11 1 11 1 11 1 11 it N O D D D r- - - -ii= 11 it L JI L.. D D D cal 11 11 II II 11 r II II 11 11 jI 11 11 II L - - - -� -- IL - - - -J _ _II u REVIEWED FOR CODE COMPLIANCE P APP AUG 20 2012 City of Tukwila BUILDING DIVISION D D D D D DEMOLITION LEGEND EXISTING WALL ITEM TO DEMOLITION 31 CITY OF T UK\pnl n. AUG 14 2012 PERMIT CENTER Ad 7007 DISCOVERY BLVD DUBLIN. OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATE CLIENT REVIEW #### ##### PERMIT # ### ##### BID # ### ##### CONSTRUCTION ### # ### ## WD PROJECT NUMBER #### ##### r, V.1 4 DEMOLITION PLAN Z 0 cn w cc w Q 0 W 0- CC I— 0- cc W W co CC Z W CL W CO �_a cnapa OJCCY cn mo - H 0 O 0 LL. C 0 Z OC w i- < 0 (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 DRAWN BY 0 0 w J 0 c c 0 V o N 0 r (6. zQ CC O O zcc O �Q O- u) Co a_ o w=l J 0_ n 00 ooc0MOO SHEET: D -1 DOOR SCHEDULE SYMBOL SIZE DESCRIPTION FRAME HARDWARE DOOR FINISH REMARK6 FIN. METAL WOOD O 4' OPENING NEW SINGLE SLIDER - FULL OPEN ALUM ALUM 9 ALUMINUM _ DOOOR TOERRE VE110' BOTTOM RAIL 0 6' OPENING NEW BI-PART SLIDER - FULL OPEN ALUM 9 NATURAL ALUMINUM NABCO SERIES GT117504 DOOR TO RECEIVE 10" BOTTOM RAIL 0 3' -O x 6-8" EXISTING H. C. METAL OR S. C. WOOD METAL P4 2 P-4 P -5 0 3' -0" x 6'-8" NEW H. C. METAL OR S. C. WOOD METAL P-4 2 P-4 P -5 05 3'-0" x 6'-8" NEW H. C. METAL OR S. C. WOOD METAL P-4 5 P-4 P-5 PEEP HOLE 0 re A.F.F. ® 3' -0" x V-8" NEW H. C. METAL OR S. C. WOOD METAL P-4 6 P-4 P-5 07 3' -0' x 6'-8" EXISTING H. C. METAL OR S. C. WOOD METAL P-4 6 P4 P -5 ® PR. 3' -0" x 7' -0" DOUBLE - ACTING STOCKROOM DOORS CASED SUPPLIED BY TENANT ® 3' -0" x 7' -0" NEW METAL EXTERIOR DOOR METAL P-4 1 P-4 DOOR TO RECEIVE 150 DEGREE PEEP HOLE 11115'-0 A:F M4DDEUt TA-3310 10 4' -0" x 7' -0" EXISTING METAL EXTERIOR DOOR METAL P-4 1 P4 11 PR. 3' -0" x 7'-O" NEW METAL EXTERIOR DOORS METAL P4 1 P4 DooR TD REC VE 160 DEGREE PEEP HOLE @ 5'-0' A,F.F. MODEL# TA-3310 1© 10. -0" x 1O' -0" EXISTING ROLLING SERVICE DOOR W/ CHAIN HOIST METAL GRAY P4 OVERHEAD DOOR CO. SERIES 610 13 3' -0" x 7' -0" EXISTING METAL EXTERIOR DOOR METAL P4 1 P4 DOOR TO RECEIVE 180 DEGREE PEEP . HOLE Q3'-0 A.F.F MODEL# iA 3110 14 3' -0" x 6'-8" NEW H. C. METAL OR S. C. WOOD METAL P4 1 P-4 P-5 HARDWARE NOTES GROUP 1 (TYPICAL H.M. SERVICE DOORS) EACH TO RECEIVE: 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4-1/2 , NRP, US26D 1 EACH THRESHOLD 887 X REQUIRED LENGTH 1 SET WEATHER-STRIPPING 1 EACH DRIP CAP 1 EACH PANIC DEVICE - GUARD -X 2670 w/ CYLINDER TO ACCEPT 7 PIN KEYWAY 1 CLOSER, 1461, AL LCN 1 180 DEGREE DOOR VIEWER - TA -3310 ** IF DOUBLE DOORS: -1 EACH DOUBLE -DOOR HOLDER DDH -2250 DETEX BOOR 14 WILL NOT REQUIRE WEATHER STRIPPING, DRIP CAP OR THRESHOLD HAGER NATIONAL GUARD ZERO RE: CONST. DOC' S VON DUPRIN NOTE: GENERAL CONTRACTOR TO ENSURE ALL EXISTING DOORS AND DOOR SYSTEMS ARE IN GOOD WORKING CONDITION. NOTIFY BIG LOTS REPRESENTATIVE OF ANY ISSUES. GROUP 2 (TYPICAL TOILET ROOM & LOUNGE DOORS) EACH TO RECEIVE: 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4 -1/2 , NRP, US26D 1 FLOOR STOP 438B 26D 1 PUSH PLATE & PULL HANDLE 1 CLOSER, 1461, AL LCN HAGER IVESS ADDITIONAL NOTE: SINGLE OCCUPANCY A.D.A. RESTROOMS 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4-1/2 , NRP, US26D 1 FLOOR STOP 438B 26D 1 CLOSER, 1461, AL 1 SINGLE OCCUPANCY RESTROOM PRIVACY LOCK #AL40PD -SAT -626 HAGER IVESS LCN ARROW GROUP 3 (ALUMINUM STOREFRONTS) EACH TO RECEIVE: PUSH BAR & PULL HANDLE 1 CLOSER, 1461, AL LCN THRESHOLD ADA APPROVED NATIONAL GUARD MANUFACTURER STANDARD OFFSET PIVOTS ONE DOOR LEAF TO RECEIVE: KEYED CYLINDER EXTERIOR 317 - 601 -26D (CYLINDER TO ACCEPT 7 PIN KEYWAY) w/ THUMB TURN INTERIOR M.S. ILCO# 7161TK2 -26D ARROW THE OTHER DOOR LEAF OF A PAIR TO RECEIVE: DUMMY MORTISE CYLINDER ILCO# 71600C -26D W/ THUMBTURN INTERIOR ILCO# 7161 TK2 -260 ARROW INSTALL ALUM. CART GUARDS ON EXTERIOR & INTERIOR OF DOORS GROUP 4 (ALUMINUM STOREFRONTS - AUTO) EACH TO RECEIVE: FULLY AUTOMATIC OPERATORS THRESHOLD ADA APPROVED MANUFACTURER STANDARD OFFSET PIVOTS ONE DOOR LEAF TO RECEIVE: KtTtU CYLINDER EXTERIOR 317 - 601 -26D (CYLINDER TO ACCEPT 7 PIN KEYWAY) w/ THUMB TURN INTERIOR M.S. ILCO# 7161TK2-26D ARROW THE OTHER DOOR LEAF OF A PAIR TO RECEIVE: DUMMY MORTISE CYLINDER ILCO# 71600C -26D W/ THUMBTURN INTERIOR ILCO# 7161 TK2 -26D ARROW INSTALL ALUM. CART GUARDS ON EXTERIOR & INTERIOR OF DOORS NATIONAL GUARD GROUP 5 (CASH ROOM DOORS) CASH OFFICE 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4-112 , NRP, US26D 1 STOREROOM SET, AL8OBD-SAT-626 (CYLINDER TO ACCEPT 7 PIN KEYWAY) 1 FLOOR STOP 438B 26D 1 CLOSER, 1461, AL 1 180 DEGREE DOOR VIEWER - TA-3310 (MOUNTING HEIGHT TO BE S -0" A.F.F.) 1 SINGLE CYLINDER DEADBOLT #E611C -26D EXTERIOR KEYWAY (TO ACCEPT 7 PIN KEYWAY) INTERIOR THUMBTURN COUNT OFFICE 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4 -112 , NRP, US26D * 1 STOREROOM SET, AL80BDSAT -626 (CYLINDER TO ACCEPT 7 PIN KEYWAY) 1 FLOOR STOP 438B 26D 1 CLOSER, 1461, AL 1 180 DEGREE DOOR VIEWER - TA-3310 (MOUNTING HEIGHT TO BE 5' -0" A.F.F.) GROUP 6 (TYPICAL OFFICE DOORS) EACH TO RECEIVE: 1 -1/2 PAIR BUTTS, BB1279, 4 -1/2 X 4-1/2 , NRP, US26D * 1 STOREROOM SET, AL8OBD- SAT -626 (CYLINDERS TO ACCEPT 7 PIN KEYWAY) 1 FLOOR STOP 438B 26D 1 CLOSER, 1461, AL HAGER ARROW IVESS LCN ARROW HAGER ARROW IVESS LCN HAGER ARROW IVESS LCN GROUP 8 (ALUMINUM STOREFRONT EMERGENCY EXITS) EACH TO RECEIVE: PUSH BAR & PULL HANDLE 1 CLOSER, 1461, AL LCN THRESHOLD ADA APPROVED NATIONAL GUARD MANUFACTURER STANDARD OFFSET PIVOTS 1 EACH PANIC DEVICE - GUARD -X 2670 VON DUPRIN w/ CYLINDER TO ACCEPT 7 PIN KEYWAY GROUP 9 (SLIDING GLASS DOORS) EACH TO RECEIVE: FULLY AUTOMATIC OPERATORS THRESHOLD ADA APPROVED TO RECEIVE: KEYED CYLINDER EXTERIOR 317 -601 -26D (CYLINDER TO ACCEPT 7 PIN KEYWAY) w/ THUMB TURN INTERIOR M.S. ILCO# 7161TK2 -26D INSTALL ALUM. CART GUARDS ON EXTERIOR & INTERIOR OF DOORS NATIONAL GUARD ARROW ADDITIONAL HARDWARE NOTE: - BASS LOCK WILL PROVIDE PADLOCKS FOR OVERHEAD DOORS AND ROOFHATCH. THEY WILL ALSO PROVIDE ONE (1) SPARE LOCK. H.C. WATER CLOSET SPRINKLER RISER ELECTRIC REVIEVVE OR-"'. CODE COMPLIANCE APPROVED AUG 2 0 2012 City of Tukwila BUILDING DIVISION/ LEGEND /linos ∎ii, \— COMPACTOR DOOR TO BE WELDED SHUT 10'-6" EXPAND VESTIBULE AS SHOWN AND REPLACE DOORS WITH SLIDERS STOCKROOM 4,898 SqFt 147'4" SALES FLOOR 20,604 SqFt i1 II. fpi SRI WOMEN 12:1 o to IN -FILL WALL TO MATCH EXISTING Iaisn iii I EXPAND WATER COOLER AREA FOR NEW HI-LO WATER COOLERS NOTE: ALL EXISTING TOILETS, URINALS, LAVATORIES, FAUCETS, FLUSH VALVES AND PARTITIONS TO BE IN LIKE NEW CONDITION. GC TO VERIFY ALL ACCESSORIES, FIXTURES, ETC IN THE PUBLIC RESTROOMS ARE TO BE IN COMPLIANCE WITH WASHINGTON STATE ACCESSIBILITY REQUIREMENTS. REPLACE ALL TOILET SEATS WITH COMMERCIAL GRADE OPEN FACE SEATS. ALL SEWER LINES TO BE INSPECTED & SCOPED TO ENSURE FUNCTIONAL, UNOBSTRUCTED AND UNDAMAGED. A1.1 P -# A1.1 2,51 NEW WALL EXISTING WALL DETAIL/NOTE SHEET NUMBER WALL DETAIL/NOTE SHEET NUMBER FINISH SCHEDULE SHEET NUMBER 18' -11" ,., 12' 6266 wd 7007 DISCOVERY BLVD DUBUN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW PERMIT #####1##/## BID CONSTRUCTION ########## WD PROJECT NUMBER 0 a w 0 1- r z LL w 0 _1 0 z TOTAL: 27,497 NtLC:IVtLi CITY OF TUK11ti 1. AUG 14 2012 PERMIT CENTER LOUNGE NEW DOORWAY AND DOOR MANAGER OFFICE COUNT 3/32" = 1' -0" 0 0 c 0 M CO CVCO 0 W 0 i0 RAMP AND LANDING TO GRADE. MAX SLOPE 1 :12. PROVIDE HANDRAIL AS REQUIRED PER ICC /A117.1 IN -FILL DOORWAY TO MATCH EXISTING CONSTRUCTION PLAN SHEET: A -1 DOOR SCHEDULE SYMBOL SIZE DESCRIPTION FRAME HARDWARE DOOR FINISH REMARKS TYPE FIN. METAL IWOOD 0 4' OPENING NEW SINGLE SLIDER - FULL OPEN ALUM 4" VINYL WALL BASE ARMSTRONG #60 9 NATURAL ALUMINUM DOOR TO R dgIVE 1 "BO DOOR TO REOEIVE 10" BOTTOM RAIL 2 6' OPENING NEW BI -PART SLIDER - FULL OPEN ALUM O z co co x w 9 NATURAL ALUMINUM NABCO SERIES GT1175 -04 DOOR TO RECEIVE 10" BOTTOM RAIL © 3` -0'° x 6' -8" EXISTING H. C. METAL OR S. C. WOOD METAL P -4 2 P -4 P -5 ! 3' -0" x 6-8" NEW H. C. METAL OR S. C. WOOD METAL P -4 2 P -4 P -5 5 3' -0" x 6' -8" NEW H. C. METAL OR S. C. WOOD METAL P -4 5 P -4 P -5 PEEP HOLE 0 6- 0 "A.F.F. © 3.-Cr x 6-8" NEW H. C. METAL OR S. C. WOOD METAL P -4 6 P-4 P -5 ©7 3' -0" x 6' -8" EXISTING H. C. METAL OR S. C. WOOD METAL P -4 6 P -4 P -5 ® PR. 3" -O' °x 7-0" DOUBLE - ACTING STOCKROOM DOORS CASED INTERIOR STEEL COLUMNS SUPPLIED BY TENANT p 3' -0" x 7' -0" NEW METAL EXTERIOR DOOR METAL P -4 1 P -4 HOORTOE Ieo DEGREE PEEP HOLE.( 5' -,0" 0" A A. FF..F. MODELM TA -3310. 1 D 4' -0" x 7-0" EXISTING METAL EXTERIOR DOOR METAL P -4 1 P -4 0 PR. 3' -0" x 7' -D" NEW METAL EXTERIOR DOORS METAL P-4 1 P -4 DOOR TO RECEIVE 180 DEGREE PEEP HOLE 0 5' -0' A. F . MODEL# TA -3310 10' -0 "x 10' -0" EXISTING ROLLING SERVICE DOOR W/ CHAIN HOIST METAL GRAY P -4 • OVERHEAD DOOR CO SERIES 610 T3 3' -0" x 7-0" EXISTING METAL EXTERIOR DOOR METAL P -4 1 P -4 • HOLE 0 DOOR TO RECEIVE 180 DEGREE PEEP . 5 ' -0" A.F.F MOOELA TA -3310 14 3' -0" x 6' -8" NEW H. C. METAL OR S. C. WOOD METAL P -4 1 P -4 P -5 NOTE: GENERAL CONTRACTOR TO ENSURE ALL EXISTING DOORS AND DOOR SYSTEMS ARE IN GOOD WORKING CONDITION. NOTIFY BIG LOTS REPRESENTATIVE OF ANY ISSUES. ROOM FINISH SCHEDULE ROOM & OR AREA FLOOR BASE WALLS CEILING REMARKS SURFACE MATERIAL HEIGHT VCT, AZROCK CLOUD WHITE #V -862 EXISTING CERAMIC TILE SEALED CONCRETE NON -SKID VCT. AZROCK GRANITE SR #120 -3 O z 1= m x w 4" VINYL WALL BASE ARMSTRONG #60 DRYWALL OR SURFACES DRYWALL PAINTED ACCOUSTICAL TILE CERTAINEED BET197 EXPOSED DECKING 9' -0" AFF Z-0" AFF 14'-0" AFF O z co co x w VESTIBULE • • P -1 • ! • SALES AREA: • • • • • SIDE WALLS FRONT & REAR WALLS P-1 P-3 INTERIOR STEEL COLUMNS P-10 LOUNGE • • P -1 • • WOMEN'S RESTROOM • • P -6 • • MEN'S RESTROOM • • P -6 • • MANAGER'S OFFICE • • P -1 • • COUNT ROOM • • P -1 P -1 • CASH ROOM • • P -1 P -1 • STOCK ROOM P-11 P -9 • MOP SINK AREA P -11 • P -8 • RESTROOM ENTRY • • P -1 • • WATER COOLER AREA • • P -1, P -7 • • ELECTRIC & SPRINKLER P -11 • P -1 • NEW RESTROOMS • • P -6 • • IN ERIOR FINISH LEGEND P -1 P -3 P -4 P -5 P -6 P -7 P -9 P -10 P -1 GEEI SHERWIN WILLIAMS - PROMAR 200 LATEX - EGGSHELL FINISH - #SW6385 - DOVER WHITE SHERWIN WILLIAMS - PROMAR 200 LATEX - EGGSHELL FINISH - #SW6258 - TRICORN BLACK SHERWIN WILLIAMS - PRODUCT# A41 B8200 - ALL SURFACE ENAMEL - ACRYLIC LATEX GLOSS, BLACK WALNUT STAIN WITH POLYURATHANE FINISH FIBERGLASS REINFORCED PLASTIC "FRP" BRITE WHITE WITH T- MOLDING & J- MOLDING ON ALL WALLS FROM FLOOR TO CEILING. FIBERGLASS REINFORCED PLASTIC "FRP" BRITE WHITE WITH T- MOLDING & J- MOLDING ON WALL BEHIND WATER COOLER FROM FLOOR TO CEILING. FIBERGLASS REINFORCED PLASTIC "FRP" BRITE WHITE WITH T- MOLDING & J- MOLDING ON WALL BEHIND MOP SINK FROM FLOOR TO MAX. 8' -0" A.F.F. INSTALL PLYWOOD ON T,-IE BACK OF ALL EXPOSED STOCKROOM DRYWALLS TO 4' -0" A.F.F. SHERWIN WILLIAMS - DTM #B66W111 - GLOSS FINISH - #SW6385 - DOVER WHITE CONCRETE FLOOR SEALER EUCO DIAMOND CLEAR #18178 APPLICATION - FLOOR TO BE SCRUBBED AND APPLY 3 COATS WITH ROLLER - NO SPRAY APPLICATIONS SHERWIN WILLIAMS - BRILLIANT WHITE - DRY FALL FLAT FINISH - B48W60 EXTERIOR FINISH SCHEDULE EP -1 EP -2 EP -3 BUILDING EXTERIOR & SIGN EFIS AREAS - SHERWIN WILLIAMS A100 SATIN - #SW6350 INTRICATE IVORY METALANOOD BUILDING TRIM & ROOF CAPS - SHERWIN WILLIAMS A100 GLOSS - #SW6258 - TRICORN BLACK INTERIOR AND EXTERIOR WINDOW MULLIONS SHERWIN WILLIAMS BOND -PLEX WATER BASED ACRYLIC COATING B71 -200 SERIES - SW6258 - TRICORN BLACK (ONLY APPLIES IF MULLIONS ARE NOT CLEAR OR DARK BRONZE FINISH) NOTE: GENERAL CONTRACTOR TO ENSURE ALL EXISTING WINDOW MULLIONS ARE IN GOOD WORKING CONDITION. NOTIFY BIG LOTS REPRESENTATIVE OF ANY ISSUES. 7' 4' N T T 2' 1 2 RUBBER BUMPER i , , SPINNER 2" RUBBER BUMPER 6" STAINLESS STEEL LEGS 7' CUSTOMER ELEVATION CCHECKOUT DETAILS /4" . 1' -0 7' PLAN VIEW 7' 0 2' 6" STAINLESS STEEL LEGS CUSTOMER ELEVATION 14 FURNITURE CHECKOUT DETAILS 1/4" = 1' -0" 2" RUBBER BUMPER EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION ADJACENT TENANT SPACE EXISTING METAL DECKING FIRE STOPPING AS REQUIRED BY CODE 2x4' LAY -IN CEILI BO BIG LOTS SPACE 14" -0" GYPSUM BOARD SIDES TAPE, SPACKLE, SAND 6" METAL STUDS @ 16 EXISTING FLOOR 0, -0" A.F.F. DEMISING WALL SECTION 1/4" = 1 " -0" EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION EXISTING METAL DECKING FIRE STOPPING AS REQUIRED BY CODE 12' -0" A.F.F. CEILING 2x4' LAY -IN CEILING 5/8 GYPSUM BOARD BOTH. SIDES TAPE, SPACKLE, SAND STOCK ■ CORRIDOR ROOM 6" METAL STUDS @ 16" O.C. 3/4" X 48" CID GRADE PLYWOOD WAINSCOT EXISTING FLOOR CORRIDOR WALL SECTION 1/4" = 1' -0" 0' -0" A.F.F. FINISH FLOOR 4 4 EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION STOC ROO 1 ,.►- 5/: GYPSUM BOARD •TH SIDES TAPE, SPACKLE, SAND TI I EXISTING METAL DECKING FiRE STOPPING AS REQUIRED BY CODE 2x4' LAY - 6 " MET 12 -0" A.F.F. CEILING CEILING STUDS @ 16" O.C. 2 -2" x 6" BLOCKING IN BOTH JAMBS FOR MOUNTING STOCK ROOM OORS SALES FLOOR 6" METAL ST 7' -0" A.F.F. T.O. OPENING S @ 16" O.C. 3 /4"X48" C/D G PLYWOOD WAINSC E 2-2 x 6" BLOCKING IN BOTH JAMBS FOR MOUNTING STOCK ROOM DOORS EXISTING FLOOR 0, -0" A.F.F. P s s IS OSECT. THRU STOCK ROOM DOOR JAMB 114" = 1' -0" •e- EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION ♦YYAlaYYYA YAv SAYA VOA 1 2x4 LAY -IN CEILING RESTROOM STOCK ROOM EXISTING JOIST GIRDER 10' -6" A.F.F. T.O. GYP. BD. 9. -0" A.F.F. CEILING 5/8" GYPSUM BOARD BOTH SIDES TAPE, SPACKLE, SAND 3/4" X 48" C/D GRADE PLYWOOD WAINSCOT 6" METAL STUDS @ 16" O.C. EXISTING FLOOR 0' -0" A.F.F. FINISH FLOOR OSTOCK ROOM OFFICE WALL SECTION 1I4"=1-0 " 0 9, -0" A.F.F. T.O. GYP. BD. EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION ...®V...V...V. AVAVANYA EXISTING JOIST GIRDER /---3/4" NON -COM PLYWOOD 9' -0" A.F.F. CEILING '-6" METAL STUDS @ 16" O.C. 5/8" GYPSUM BOARD TAPE, SPACKLE, SAND CASH COUNT OFFICE OFFICE 0 5/8" GYPSUM BOARD BOTH SIDES TAPE, SPACKLE, SAND 3 -5/8" METAL STUDS @ 16" O.C. EXISTING FLOOR 0. -0" A.F.F. FINISH FLOOR (IDCASH/COUNT OFFICE WALL SECTION 1/4" = i' -0" EXISTING ROOF (BUILT•UP, OR RUBBER) EXISTING RIGID INSULATION VA.AV.V...VAV,V..A.A.AV. 3/4" NON -COM PLYWOOD EXISTING JOIST GIRDER 2'x4' LAY -IN CEILING 6" METAL STUDS @ 16" O.C. 5/8" GYPSUM BOARD TAPE, SPACKLE, SAND COUNT OFFICE OFFICE 5 /8" GYPSUM BOARD BOTH SIDES TAPE, SPACKLE, SAND 3 -5/8" METAL STUDS @ 16" O.C. EXISTING FLOOR OOFFICE WALL SECTION 1 /4" = 1' -0" 0'.0" A.F.F. FINISH FLOOR s s EXISTING ROOF (BUILT -UP, OR RUBBER) EXISTING RIGID INSULATION YAIFAVAUFATMANA SA F OR EXISTING JOIST GIRD 3 -5/8" METAL 2'x4' UDS @ 16" O.C. Y -IN CEILING OFFICES '- BOTH SIDES UM 10' -6" A.F.F. T.O. GYP. BD. 9. -0" A.F.F CEILING ARDPACKLE, SAND 3-5/8" METAL STUDS@ 1 EXISTING FLOOR 0. -0" A.F.F. FINISH FLOOR OSALES FLOOR OFFICE WALL SECTION 1/4" = 1' -0 "' EXISTING ROOF (BUILT -UP, OR. RUBBER) EXISTING RIGID INSULATION YYY, #AVA74jAY4 4 jjV ## AVA LOUNGE EXISTING JOIST GIRDER 3 -5/8" METAL STUDS @ 16" O.C. 2x4' LAY- CEILING RESTROOM 12-0" A.F.F. T.O. GYP. BD. 9' -0" A.F.F. CEILING 518" GYPSUM BO - D BOTH SIDES TAP PACKLE, SAND 3 -5/8" METAL STUDS @ 16 EXISTING FLOOR RESTROOM /LOUNGE WALL SECTION 0, -0" A.F.F. FINISH FLOO 1/4" = 1 -0" • 40" A.F.F. U SU TCE- 4 0, -0" A.F.F. FINISH FLOOR 4 COUNTER SURFICE 4 30" A.F.F. O' -0" A.F.F. FINISH FLOOR COUNT OFFICE CASH OFFICE C.) OFFICE COUNTER ELEVATIONS 1/4" = 1' -0" 40" A.F.F. COUNTER UNTER SURFICE 0, -0" A.F.F. FINISH FLOOR 2 OPEN FOR TENANT EQUIPMENT A.F.F. COUNTER SURFICE 0' -0" A.F.F. FINISH FLOOR 4 4 DRINKING FOUNTAIN HANDICAP DRINKING FOUNTAIN 0' -0" A.F.F. FINISH FLOOR REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 0 2012 City of Tukwila BUILDING DIVISION ELKAY MODEL EZSTL8LC HI -LO WATER COOLER MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 4 0. -0" A.F.F. FINISH FLOOR WATER COOLER ELEVATION 1/a" = 1' -0" z m • 1)12. 2..31 0' -0" A.F.F. FINISH FLOOR 0 HAND DRYER ELEVATION 1/4" = 1 -0 INSTALL ELECTRIC HAND DRYER, EXCEL MODEL XL -W WITH RECESS KIT, MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 0' -0" A.F.F. FINISH FLOOR 12 BABY CHANGING TABLE 1/4" = 1-0" v d 7007 DISCOVERY BLVD DUBLIN, 011.43017 614.634.7000 T WDPARTNERS. COM ISSUE DATE CLIENT REVIEW ######### PERMIT # # ##### ## BID ####### ## CONSTRUCTION ######### WD PROJECT NUMBER ######### v rt7Y O 3�IK,t ,31 AUG 14 2012 PERMIT CENTER CONSTRUCTION NOTES W 0 Q CC CC U..f Z cc LLJ W ©p CC Z co LLI w 00 i< Cn F- (I) J 0 CC 4 ri CC W a_ T H LI..I. I- 0 0 0 NJ z 0 a 0 0 O J TOTAL: 27,497 DRAWN BY J 0 CO (� 0- N Z W M o 0 CO W z co Ozcc O_N I- Z QT "J IZ J _Icc0Dz J 2F-oOI FacncoOa SHEET: A -1.1 ATTENTION FIXTURE INSTALLER FIXTURE NOTES: 1) 48" GONDOLA RUN AT THE SERVICE COUNTER TO HAVE 22" DEEP BASE DECKS, (2) SHEETS OF 46 "x 40" PEGBOARD ONE ON EACH SIDE PER 4' SECTION. 2) 72" GONDOLA RUNS TO HAVE 22" DEEP BASE DECKS, (2) SHEETS OF PEGBOARD OF 46 "x 64 ", ONE ON EACH SIDE PER 4' SECTION. 72" END CAPS TO HAVE 48 "x 22" BASE DECKS, 72" UPRITES, (2) SHEETS OF PEGBOARD OF 46 "x 64" ONE ON EACH SIDE PER 4' SECTION, (2) BASE END TRIMS & (2) UPRITE END TRIMS. 3) 84" GONDOLA RUNS TO HAVE 22" DEEP BASE DECKS, (4) SHEETS OF PEGBOARD, (2) 46 "x 40" & (2) 46" x 36 ", ONE SIZE OF EACH ON EITHER SIDE PER 4' SECTION. 84" END CAPS TO HAVE 48 "x 22" BASE DECKS, 84" UPRITES, (4) SHEETS OF PEGBOARD, (2) 46 "x 40" & (2) 46" x 36 ", ONE SIZE OF EACH ON EITHER SIDE PER 4' SECTION, (2) BASE END TRIMS & (2) UPRITE END TRIMS. 4) 54" WALLCASE RUNS HAVE 25" DEEP BASE DECKS, (2) SHEETS OF 46" x 46" PEGBOARD, ONE ON EACH SIDE PER 4' SECTION. 5) 84" WALLCASE RUNS HAVE 25" DEEP BASE DECKS, (2) SHEETS OF PEGBOARD, (1) 46 "x 40" & (1) 46 "x 36" PER 4' SECTION. 24' -0" NESTAFLE LU CC Z cca D CC LU CC 0 HZ ct Q CC U_ � z C_ Q U_ CC FURNITURE I FURNITURE I RACKING RACKING FURNITURE FURNITURE RACKING RACKING FURNITURE FURNITURE RACKING RACKING CC 0 Z Y ¢a LL CC C= 0 H Z CCQ 7 CC O z 0 cc O z U SHELVING AND RACKING TO BE INSTALLED SUCH THAT NO MERCHANDISE SHALL BE STACKED HIGHER THAN 12' -0" AFF. STOCKROOM 4,898 SqFt NEW RESTROOMS 0 SPRINKLER RISER O ELECTRIC 0 z Y z 2 0 Z 2 0 W' r m CC 0 D Z D_ Q LL � w CE0 Z Y �Q D CC F�1 Q WOMEN FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING FURNITURE RACKING CC 0 D ~ Y ¢ ¢ U- H Z za 0 CC LI 84" LAMP MDF ALL n cc cc Fl 0 FURNITURE DEPARTMENT 2,323 SqFt 0 "DV2 co 0 u 16 72" 72" 72" 72" 72" 72 72' 0 72" 72" 84" 84' 84 84. 84" z 0 w 0 z a. to w 0 z a w w 1 NVdS2OIM j 12' 1 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 14' L- /L./ \J\J CO co CO CO 03 CO O 19' 0 m O 0 0 84" V REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 0 2012 City of BUILDINGTDIV SI DIVISION MANAGER OFFICE COUNT CC w w z Z 0 0 LOUNGE CASH C= w z 0 0 V�d 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW # # ### ##### PERMIT # #### # # # ## BID # #### # # # ## CONSTRUCTION # #### # #### WD PROJECT NUMBER # #### #### 6266 ARCHTER JO FIXTURE PLAN REutiVC.1,3 CITY OF 111K';,\ AUG 14.2012 PERMIT CENTER AULi 0 z 0 w cC LOGOS WASHINGTON 7 2012 w a 0 CC EC W a Z W 11.1 co CC W W 0 D = Q (n ~ g2 o to OCC cY ca _ SQUARE FOOTAGE 0 0 0 N' (1) J CO 1- C w 0 w 1- Z w w 0 0 0 J z TOTAL: 27,497 DATE DRAW N L9 DRAWN BY "C7 0 CO U o_ N ZW CNo 0 92 C9 W 0Q00�0 O zcrO_ !HZ— `^ '- O W = W O 10 51 0 m(nco0o_ SHEET: A -2 LEGEND (GYP) GYPSUM BOARD (ACT) ACOUSTIC TILE EGRESS/ EXIT DISCHARGE LIGHTING NOTES: ALL INTERNALLY ILLUMINATED EXIT LIGHTS SHALL BE LISTED UL 924 AND HAVE RED ILLUMINATED FACE OR PHOTO - LUMINESCENT. 1. ALL EXIT SIGNS TO BE ILLUMINATED AT ALL TIMES THE BUILDING IS OCCUPIED AND HAVE EMERGENCY POWER TO PROVIDE ILLUMINATION OF A MINIMUM OF 90 MINUTES IN CASE OF PRIMARY POWER FAILURE. 2. UPON COMPLETION OF THE CONSTRUCTION AND PRIOR TO OCCUPANCY THE GENERAL CONTRACTOR SHALL CALL FOR FINAL INSPECTIONS OF ALL THE EMERGENCY LIGHTING SYSTEMS, OPERATION AND PLACEMENT. FINAL LOCATIONS AND QUANTITIES OF FIXTURES WILL BE DETERMINED BY THE INSPECTOR DURING INSPECTION TO ADEQUATELY ILLUMINATE ALL MEANS OF EGRESS. 3. THE EMERGENCY LIGHTING SHALL PROVIDE A MINIMUM OF NOT LESS THAN 1fc ALONG ALL PORTIONS OF THE PATH OF EGRESS INCLUDING THE EXTERIOR EXIT DISCHARGE LANDING. LIGHTING NOTES 1. ALL LIGHT FIXTURES IN THE STOCK OR STORAGE AREA TO BE HUNG AT 14'AFF. 2. WHEN APPLICABLE ALL LIGHT FIXTURES IN THE SALES FLOOR TO BE HUNG FROM THE BOTTOM OF THE CEILING GRID BY THE CLIPS PROVIDED. 3. ALL PERIMETER LIGHTING FIXTURES ON THE SALES FLOOR TO BE MOUNTED BETWEEN 4' TO 6' FROM ANY WALL AND 10' ON CENTER WHERE APPLICABLE, ROWS SHOULD RUN LEFT TO RIGHT FROM STORE FRONT. 4. ALL THE LIGHT FIXTURES IN THE STOCK OR STORAGE AREAS TO BE MOUNTED AT 12' -0" ON CENTER 5. ALL TRACK LIGHTING TO BE INSTALLED AT 6" BELOW STRIP LIGHTING 6. ALL LIGHT FIXTURES TO BE (METALUX) #SSF- 232- OS- QHE2X32T &UNISNSC -U (4') AND (METALUX) #8TSSF- 232- UNV -OS- QHE4X32T8UNVISNSC -U (8') AND SHALL HAVE 4' T -8 SYLVANIA LAMPS, PART# SYL F028 /841XP /SS /ECO AND SYLVANIA ELECTRONIC BALLAST PART# QHE2X32T8UNISNSC -U (4') AND QHE4X32T8UNVISNSC -U (8'). 7. ALL EMERGENCY FIXTURES TO BE (METALUX) #8TSSF- 232- 120v- OS- EL- FBP24OH -0SQHE4X32T8UNVISNSC -U . 8. THE EMERGENCY EXIT SIGN WILL BE A TECHNICAL CONSUMER PRODUCTS PART# TCP 22743 AND A REMOTE HEAD TECHNICAL CONSUMER PRODUCTS PART# TCP 207R4 9. ALL CHANGES TO BE APPROVED BY A BIG LOTS, INC. REPRESENTATIVE. 10. ALL WORK TO BE DONE IN A WORKMAN LIKE MANOR, WITH A ONE YEAR WARRANTY ON THE LABOR AND MATERIAL OF INSTALLATION. 11. ALL LOCATIONS TO BE FIELD VERIFIED. LIGHTING LEGEND REMOTE HEAD - TECHNICAL CONSUMER PRODUCTS PART# TCP 207R4 e EMERGENCY /EXIT RED LED EXIT SIGN - TECHNICAL CONSUMER PRODUCTS PART# TCP 22743 EMER NEW 2 LAMP 4FT STRIP - (METALUX) #SSF- 232- OS- QHE2X32T8UNISNSC -U - SYLVANIA LAMP PART# SYL F028 /841XP /SS /ECO (48W) NEW 4 LAMP 8FT STRIP - (METALUX) #8TSSF- 232- UNV -OS- QHE4X32T8UNVISNSC -U - SYLVANIA LAMP PART# SYL F028/841XP/SS/ECO (95W) NEW 4 LAMP 8FT EMERGENCY STRIP -(M ETALUX) # 8TSSF - 232- 120v- OS- EL- FBP240H- 0SQHE4X32T8UNVISNSC -U - SYLVANIA LAMP PART# SYL F028/841 XP /SS /ECO (95W) LIGHTING TAKE OFF Count Name ',r . - - - ' . • , • 14 TCP #22743 - RED LED EXIT SIGN • a i t 38 4 LAMP - 8' EMERGENCY STRIP 271 4 LAMP 8' STRIP 4 4' TRACK LIGHTS DAP 9. -4" cc w W 2 W 12' 5.-4" 12' 12' cc w w w W 0 5' 12' n n REVCOMPLIANCE CODE APPROVED AUG 2 0 2012 City of Tukwila BUILDING DIVISION n 10" 2 cc cc cc 1 1 9' 4' -7 0 0 0 cc / e 10' 10' t9' i t0' 1 10' t0' 10' 10' 10' 1 10' 1 10' 10' 1 1 4 0 0 0 0 0 cr w W I1 wzi 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS .COM ISSUE DATES CLIENT REVIEW ### ### #### PERMIT # ######### BID ##### # #### CONSTRUCTION ########## WD PROJECT NUMBER # #### #### Rt/••��l,tiVr.j CITY OP 11JKV;!rf n AUG 1 4.2012 PERMIT CENTER LIGHTING PLAN z 0 w w 1- 0 cc cc � Zcc w wco Z w LLI co D = < (0 Q0< m Ooh SQUARE FOOTAGE 0 0 N -J 1- D w 0 w 1- z CC ar ELI 0 J z TOTAL: 27,497 DATE DRAW DRAWN BY C .0 Q N CO CO 0a. N Z w c�a - 0 r co c9 w z¢Oco O cc 0 cal —^ r� VJ < ET- VJ D cop J m O WE 2W Joca_ Jz O I- 0 0 00X0002 SHEET: A -3 THIS DRAWINGS IS FOR SCHEMATIC INFORMATION ONLY. A LOCALLY LICENSED FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR FINIAL DESIGN LAYOUT AND REQUIREMENTS OF ANY MODIFICATIONS TO THE FIRE ALARM AND SPRINKLER SYSTEMS FOR THIS SPACE. SEALED DRAWINGS AND CALCULATIONS SHALL BE PROVIDED AND SUBMITTED FOR PERMITTING AND APPROVAL THROUGH THE PROPER AUTHORITIES PRIOR TO ANY WORK ON THESE SYSTEMS. FINAL DESIGN AND INSTALLATION SHALL BE IN COMPLIANCE WITH NFPA 13 AND ALL LOCAL CODE REQUIREMENTS. Big Lots New Store FA System Requirements FA System Information Contact Michael Poe (614) 278 -6846, epoe @biglots.com Fire Alarm Systems: Big Lots requires that all Fire Alarms (FA) be installed per the Authority Having Jurisdiction for the area. If the AHJ does not require a FA for the space Big Lots will require that the flow and tamper switches from the sprinkler system serving the space be monitored. Big Lots (BL) uses Consolidated Fire Protection (CFP) to monitor all FA's installed in new stores. Following the installation of the FA by the LL or GC, CFP will take over the monitoring. No third party monitoring will be needed. CFP needs to monitor any FA directly from two installed phone lines. Depending on the needs of the GC to pass C of 0 inspections the GC may install these lines and transfer them to BL following the inspections. If the FA has been installed by a third party the LL or GC should be prepared to supply CFP with all necessary programming information including zones, passwords, etc. The GC and FA installers should be prepared for direct contact by a CFP representative to facilitate scheduling for the reprogramming of the FA panel. LL or GC must provide Big Lots with answers to the following questions following the execution of the lease: • Does the GC intend to install a FA exclusive to our space or is it going to be integrated into a larger LL system? If the FA is exclusive to Big Lots please see notes below. • If the FA is part of a larger LL system please provide information regarding monitoring company and contact numbers to add Big Lots store associates to the call list. LL or GC must provide Big Lots with the following information after the FA installer has been selected: • Site drawings in CAD format of the proposed FA • Any plan review notes regarding FA installation as required by the AHJ. • Contact information for the installing FA company • FA installer specifications such as panel type, devices, etc. • Inspection forms, record of completion, and as- builts left at the panel location in a binder per NFPA standards. Big Lots also require that the installing FA company install a FA that can be monitored and repaired by CFP. BL requires use of one of the FACP's as Fisted below: • FireLite MS9050 • Firelite MS9200UDLS • Firelite MS9600 • Firelite 5 • Honeywell Vista 128FB • EST 2 • EST 3 • Bosch 7412 • Bosch 9412 • Honeywell Vista 100 • Silent Knight 5208 • Silent Knight 5808 • Silent Knight 5820 CFP to be notified two weeks before date of requested conversion. All communications formats for monitoring are to be in Contact ID. Permitting and Inspections - Please communicate all ongoing FA permitting issues, timelines, installation deadlines, and completion dates with Michael Poe If the LL is interested in contacting CFP directly for FA installation quotes: Elizabeth Parker - Consolidated Fire Protection - 949 - 870 -3979, eparker@cfpfire.com The GC will be responsible for contacting Celeste Doane (614 -278 -7041) to transfer phone lines following the installation of the FA. SPRINKLER RISER 84" LAMP ALL ELECTRIC Dz I-- cc CC LL 0 z 0 Icy Z CCa D CC CC 0 D Z H2 n 2 LL O z cc FURNITURE FURNITURE RACKING RACKING FURNITURE FURNITURE RACKING RACKING FURNITURE FURNITURE RACKING RACKING STOCKROOM 4,898 SqFt NEW RESTROOMS 0 ..r_. i ®IO I i LU CC 0 �z F- Z cr LL FURNITURE RACKING FURNITURE FURNITURE FURNITURE FURNITURE FURNITURE RACKING RACKING RACKING RACKING RACKING FURNITURE RACKING cc 0 Fz — 2 Z cc 2 6' 84" MDF 1- cc cc 1- 0 FURNITURE DEPARTMENT 2,323 SqFt 84" \84" O 84" 4' -6" 4' -6" , 4' -6" 'v 4' -6' 4' -6" 4'-6° 4' -6" CO CO 14 CO C u u u 84" 8 84" WIDESPAN WIDESPAN 7 z o- w w 0 ,f3 NVdS34IM 12 n 72" 7 72" 72" 72" 72" 72" 72" 72" C 72" i i 72" 72" 6 72" 72" 72" 72" 72" 72" 72„ 72" 1 O 72" 72" 0 72" u 84" 19' L /L' \J\.J 0 -61„ CO o 4 co 4' -6" co 0 CO 6' 6' -6" m H w 0 0 0 6 6-6" MANAGER OFFICE COUNT Lu w Z z 0 O LOUNGE CASH CC LU Z Z O 0 Rti..;t'tv't.0 CITY OF ` LI VP_ AUG 1 4 2012 SEPARATE PERMITGL-`hieR PERMIT AND � APPROVAL FIRE ALARM PLAN REQUIRED V�d 7007 DISCOVERY BLVD DUBLIN, OH 43017 644.634.7000 T WDPARTNERS .COM ISSUE DATES CLIENT REVIEW ####### ### PERMIT ##### # #### BID ##### # #### CONSTRUCTION ### # ###### WD PR•JECT NUMBER z 0 W cc w 0 5 W a- CC Z cc w W CO CC Z WWC (n QD © Q c —I D o Y CD ,ccri w 0 CCO w D ``0^ U) cc 0 W 0 TOTAL: 27,497 N LO (0 m Z 0 0 C .0 J ▪ II N M M (� o CO Z w M 0 00 11J Z< 02CC0 Z — VJ Q u D co • pw=2w JIYoDZ ccWc"M0o SHEET: FP -1 LEGEND E -2 NEW WALL EXISTING WALL D ETAI UNOTE SHEET NUMBER ELECTRICAL LEGEND COMMON GROUND CONVENIENCE DUPLEX RECEPTACLE TO BE NEMA 5 -20R (HUBBLE MODEL #HBL5352) COMMON GROUND CONVENIENCE DOUBLE DUPLEX RECEPTACLE TO BE NEMA(2)- {5 -20R (HUBBLE MODEL #HBL5352)} ISOLATED GROUND TWIST LOCK DUPLEX RECEPTACLE TO BE NEMA L5 -15R HUBBELL IG4700A MOTION ACTIVATED SWITCH LEVITON PART# ODS10 -IDW (SEE NOTE #20 SHEET E -2) J BOX FOR SIGN 0 TELECOM. ROUGH -IN CAT -5 ROUGH -IN DOORBELL FP DISCONNECT SWITCH DB I CORD REEL (SEE NOTE #5 SHEET E -2) ELECTRIC PANEL SPRINKLER RISER ELECTRIC NEW RESTROOMS 0 MEN WOMEN 10. -51° 22—T' N 30' LAMP WALL 21 POWER POLE e II 84" 0 0 84" 9 -1' 3' -11" 12-6" 0 O 0 O 0 O 0 °N V F SEPARATE PERMIT AND APPROVAL REQUIRED MANAGER OFFICE 0 LOUNGE 0 AEI CASH 0 e w z Z D O U wd 7007 DISCOVERY BLVD DUBUN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATE; CLIENT REVIEW ### # # # ##4 PERMIT #### # ###t BID #### ### #t CONSTRUCTION #### # ###t WD PROJECT NUMBER ### # ##### o'"s. AUG 14 2012 P=ERMIT CENTER ER ELECTRIC PLAN Z 0 0 w cr w F 0 w 0 0 w 0 Q Z 0 w H 0 N L) co W CO O N (1) w J (1) (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 DRAWN BY w J ^^ vJ c c c op U0 N Z w — M o 0 op w z < clOY 00 Q ZECON HZ— •t- cn < 0- (/) r- O w = 2 w J m 0_ D Z C'3Qo0 Q 0 m CO co 0- SHEET: E -1 BASIC WIRING REQUIREMENTS • PLEASE REVIEW SPECIFICATIONS BELOW AND REFER TO SHEET E -1 FOR DESIGNATED LOCATIONS. • NO ADDITIONS OR CHANGES TO THIS SCOPE OF WORK CAN BE MADE WITHOUT PRE - APPROVAL BY AUTHORIZED BIG LOTS REPRESENTATIVE. • ALL WORK IS TO BE DONE IN A WORKMAN -LIKE MANNER, AND THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, AND COMPLIANCE TO ALL NATIONAL AND LOCAL CODES AND REQUIREMENTS. EXISTING CIRCUITS AND RECEPTACLES ARE TO BE UTILIZED IN ALL CASES IF COST EFFECTIVE. PLEASE BREAK YOUR BID DOWN BY LINE ITEM WITH SPECIFICATIONS ON LABOR COSTS AND MATERIAL. • ELECTRICIAN IS ALSO TO RETURN TO THE STORE 3 -7 DAYS PRIOR TO DRY RUN OPENING TO VERIFY STORE LIGHTING IS FULLY FUNCTIONAL AND MAKE WHATEVER REPAIRS THAT MAY BE NEEDED. ANY QUESTIONS PLEASE CALL: 614 - 278 -6719 or 614 - 278 -6946. THANK YOU FOR YOUR ATTENTION IN THIS MATTER. TABLE OF CONTENTS 1. CASHWRAP CABINETS /FURNITURE CABINETS 2. EXTERIOR SIGNS 3. AUTOMATIC DOORS 4. CONVENIENCE RECEPTACLE 5. CORD REELS 6. COUNTDOWN ROOM 7. CASH ROOM 8. EMPLOYEE LOUNGE 9. MANAGER OFFICE 10. BALER 11. DOCK LIFT 12. RECEIVING LIGHT & DOORBELL 13. PHONE SYSTEM & ALARM BOARD 14. LAMP WALL PLUG MOLD 15. STORE LIGHTING 16. DOCK LIGHT 17. WATER COOLER 18. HAND DRYER 19. MOTION SENSOR 20. DOOR KIT 1) CASHWRAP CABINETS / FURNITURE CABINETS CONTRACTOR TO PROVIDE ONE (1) 120V/20AMP ISOLATED GROUND CIRCUIT (IDENTIFIED ON DIAGRAM AS I.G.) AND TWO (2) 120V/20AMP CONVENIENCE CIRCUITS (IDENTIFIED ON DIAGRAM AS A & B), ALL CIRCUITS TO HAVE BREAKER LOCKS, FOR EACH CASHWRAP CABINET WITHIN THE STORE. CASHWRAP CABINETS • EACH CABINET TO BE SUPPLIED ELECTRICAL CONDUCTORS VIA 2.25" X 2.25" TWIN CHANNEL TELE -POWER POLE FROM OVERHEAD TO THE CABINET. LENGTH OF TELE -POWER POLE TO BE DETERMINED BY THE CEILING /DECK HEIGHT. TELE -POWER POLE, WHITE IN COLOR, SUPPLIED BY CONTRACTOR. • EACH CABINET IS TYPICALLY CONSTRUCTED WITH ELECTRICAL BOXES AND DEVICES SUPPLIED. WIRE CONDUCTORS AND CONDUIT ARE SUPPLIED BY CONTRACTOR. ALL WIRE CONDUCTORS AND CONDUIT ARE TO BE RUN HORIZONTALLY THROUGH THE CABINET AS TO NOT INTERFERE WITH ADJUSTABLE SHELF PLACEMENT. AN THE EVENT THAT THE CABINETS DO NOT CONTAIN ELECTRICAL BOXES, CONDUIT, AND DEVICES, THE CONTRACTOR IS TO SUPPLY AND INSTALL THE FOLLOWING COMPONENTS PER THE DIAGRAM BELOW. EACH CABINET REQUIRES: • ONE (1) 4 "x 4" JUNCTION BOX • FOUR (4) 2 "x 4" ELECTRICAL BOXES • ONE (1) NEMA L5 -15R ORANGE TWISTLOCK RECEPTACLE (HUBBELL IG4700A 2 POLE 3 WIRE GROUNDING 15A/125VAC) • THREE (3) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352 20N125VAC) • ALL BOXES AND DEVICES TO HAVE APPROPRIATE COVER PLATES. ® . SPECIAL PURPOSE DUPLEX RECEPTACLES BACK AND SIDE WIRED Gig NEMA L5 15R 15A 125V 0.5 HP 0.5 H DESCRIPTION CATALOG NUMBER ISOLATED GROUND, FLUSH, ORANGE RTP FACE IG4700A FRONT END CHECKOUT WIRING SCALE: NTS 2 3" DIA. HOLE (REGISTER/PC CABLES) 2 }" DIA. HOLE (CHECKOUT LIGHT) —24" SQUARE HOLE (POWER POLE) a 4' BOTTOM DECK 2}" DIA. HOLE (VENDING) RIGHT ELEVATION FURNITURE CABINET • CONTRACTOR TO PROVIDE ONE (1) 120V/20AMP ISOLATED GROUND CIRCUIT (IDENTIFIED ON DIAGRAM AS I.G.) AND ONE (1) 120V/20AMP CONVENIENCE CIRCUIT (IDENTIFIED ON DIAGRAM AS A), ALL CIRCUITS TO HAVE BREAKER LOCKS, FOR THE FURNITURE CASHWRAP CABINET. • CABINET TO BE SUPPLIED ELECTRICAL CONDUCTORS VIA 2.25" X 2.25" TWIN CHANNEL TELE -POWER POLE FROM OVERHEAD TO THE CABINET. LENGTH OF TELE -POWER POLE TO BE DETERMINED BY THE CEILING/DECK HEIGHT. TELE - POWER POLE SUPPLIED BY CONTRACTOR. • EACH CABINET IS TYPICALLY CONSTRUCTED WITH ELECTRICAL BOXES AND DEVICES SUPPLIED. WIRE CONDUCTORS AND CONDUIT ARE SUPPLIED BY CONTRACTOR. IN THE EVENT THAT THE CABINET DOES NOT CONTAIN ELECTRICAL BOXES, CONDUIT, AND DEVICES THE CONTRACTOR IS TO SUPPLY AND INSTALL THE FOLLOWING COMPONENTS PER THE DIAGRAM BELOW. EACH CABINET REQUIRES: • ONE (1) 4 "x 4" JUNCTION BOX • ONE (1) 4 "x 4" ELECTRICAL BOX • ONE (1) 2 "x 4" ELECTRICAL BOX • ONE (1) NEMA L5 -15R ORANGE TWISTLOCK RECEPTACLE (HUBBELL IG4700A 2 POLE 3 WIRE GROUNDING 15A/125VAC) • TWO (2) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352 20A/125VAC) • ALL BOXES AND DEVICES TO HAVE APPROPRIATE COVER PLATES. POS/CASH REGISTER NOTES: *NOTE: UNDER NO CIRCUMSTANCES IS ANYTHING TO BE WIRED INTO THE IG RECEPTACLES. THESE ARE FOR THE DESIGNATED CASH REGISTER TWIST LOCK PLUGS ONLY! NOTE: THE GROUND WIRE IS TO TERMINATE AT THIS PANEL GROUNDING CONDUCTOR. IF SUB -PANEL IS USED FOR THESE CIRCUITS AND NO GROUND CONDUCTOR IS PRESENT, BOND TO PANEL ENCLOSURES AND CONTINUE GROUND TO CLOSEST WATER PIPE OR BUILDING STEEL. A SEPARATE HOT, NEUTRAL AND LOW RESISTANCE PATH GROUND IS REQUIRED FOR THESE CIRCUITS. CONTRACTOR TO LABEL AND RECORD AMP DRAW, PER CIRCUIT, IN PANEL BOX CIRCUIT LABEL. *NOTE: DROPS TO EACH OF THE DESIGNATED CHECK -OUTS SHOULD BE RUN IN 2 CHANNEL TELE- POLES. I.G. CIRCUITS AND CONVENIENCE CIRCUITS ARE TO BE FED THROUGH THE SAME DROP. FURNITURE CHECKOUT WIRING SCALE: NTS T 4x4 ELEC. BOX CIRCUIT A LEFT SIDE IG CIRCUIT RIGHT SIDE 0 2' 2x4 ELEC. BOX 4x4 J -BOX LEFT ELEVATION 2 " DIA. HOLE (REGISTER/PC CABLES) RIGHT ELEVATION 2) EXTERIOR SIGNS: CONTRACTOR TO PROVIDE FOR EACH BUILDING SIGN LOCATION, ONE (1) 120v /20amp CIRCUIT AND CONTROLLED BY EMS EQUIPMENT. JUNCTION BOX FOR EACH CIRCUIT TO BE LOCATED ON THE BACKSIDE OF SIGN WALL AND CENTERED WITHIN SIGN AREA (IF ANY QUESTIONS, CONTACT MICHEAL NEU 614 - 278- 6868)AFTER SIGN IS INSTALLED, FINAL ELECTRICAL CONNECTIONS TO BE COMPLETED BY ELECTRICIAN. CONTRACTOR TO PROVIDE POWER TO PYLON /STREET SIGN. POWER TO PYLON MUST ADEQUATE TO HANDLE SPECIFIED LOAD AND BE CONTROLLED BY EMS EQUIPMENT. 3) AUTOMATIC DOOR OPERATORS: CONTRACTOR TO PROVIDE ONE (1) 120v /20amp CIRCUIT TO EACH ENTRY AND EXIT STOREFRONT DOOR LOCATION, TYPICALLY FOUR (4) LOCATIONS. CIRCUITS TO TERMINATE TO A 2x4 BOX w /COVER PLATE AT THE HEADER LOCATION OF EACH DOOR. 4) CONVENIENCE RECEPTACLE : CONTRACTOR TO PROVIDE ONE (1) 120v/20amp CIRCUIT. CIRCUIT TO SUPPLY ONE (1) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLE (HUBBELL HBL 5352, OR EQUIVALENT). RECEPTACLES TO BE MOUNTED 18" AFF (OR 48" AFF IF MOUNTED TO A COLUMN). 5) CORD REELS: CONTRACTOR TO PROVIDE ONE (1) 120v /20amp CIRCUIT. CIRCUIT TO SUPPLY ONE (1) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLE, FLUSH MOUNTED IN CEILING AT EACH DESIGNATED CORD REEL LOCATION. CONTRACTOR TO INSTALL A CORD REEL AT EACH LOCATION PER THE DIAGRAM BELOW. CORD REEL DETAILS AND SPECIFICATIONS: ALEMITE CORD REEL MODEL 7260 OR EQUIVALENT TO BE: - COMMERCIAL GRADE - 20 AMP - UL RATED - 45' CORD - GFCI RECEPTACLE ALL SUPPORT WIRES FROM T -GRID BOX HANGERS TO BE SECURED TO A STRUCTURAL MEMBER. , (4)BOLTS 5/16". 18 THREADS PER INCH(STD. ALL THREAD) AT A MINIMUM OF 4" IN LENGTH,(16)WASHERS, (16 }LOCK WASHERS & (16)NUTS TO SECURE CORD REEL TO T-GRIO HANGERS T -GRID BOX HANGER (CADDY MODEL #512HO) CORD REEL 2x4 ELECTRICAL BOX (HUBBELL MODEL#410, STOCK#8XC73 OR EQUIVALENT) W/ SINGLE 20/Imp DUPLEX RECEPTACLE (IVORY. GENERAL DUTY, NEMA 5- 20R(HUBBELL STOCK#5362 OR EQUIVALENT) CORD REEL MOUNTING PLATE 6) COUNTDOWN ROOM: CONTRACTOR TO PROVIDE ONE (1) 120v /20amp CIRCUIT. CIRCUIT TO SUPPLY TWO (2) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT) RECEPTACLES TO BE MOUNTED @ 46" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 40" A.F.F. 7) CASH ROOM: CONTRACTOR TO PROVIDE ONE (1) 120v /20amp CIRCUIT. CIRCUIT TO SUPPLY TWO (2) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5232, OR EQUAL) RECEPTACLES TO BE MOUNTED @ 36" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 30' A.F.F. CONTRACTOR TO PROVIDE ONE (1) 120v /20amp ISOLATED GROUND CIRCUIT. CIRCUIT TO SUPPLY ONE (1) NEMA 5-20R ORANGE ISOLATED GROUND DUPLEX RECEPTACLES (HUBBELL CR5352IG) RECEPTACLES TO BE MOUNTED @ 36" A.F.F. DIRECTLY ABOVE THE COUNTERTOP MOUNTED AT 30' A.F.F. CONTRACTOR TO PROVIDE A TELE /DATA ROUGH -IN, A 6" BOX @ 48" A.F.F. WITH TWO(2) 2-%" EMT STUBBED ABOVE THE HARD CEILING, PULL STRING TO BE INCLUDED. THIS ROUGH -IN TO BE UTILIZED BY THE TELE/COM CONTRACTOR AT A LATER DATE. BURGLAR ALARM & MUZAK SYSTEMS: ALARM - CONTRACTOR TO PROVIDE ONE(1) 120V/20A CIRCUIT TO SUPPLY TWO(2) NEMA 5 -20R DUPLEX RECEPTACLES (HUBBLE HBL 5352 OR EQUIVALENT) WITHIN A 4" BOX @ 72" AFF, CIRCUIT TO HAVE BREAKER. MUZAK - CONTRACTOR TO PROVIDE ONE(1) 120V/20A CIRCUIT TO SUPPLY TWO(2) NEMA 5 -20R DUPLEX RECEPTACLES (HUBBLE HBL 5352 OR EQUIVALENT) WITHIN A 4" BOX @ 60" AFF, CIRCUIT TO HAVE BREAKER. 20A/120V CIRCUIT 1 - 20A/120V IG CIRCUIT 1- 2i" EMT DATA CHASE 2 - 20A/120V CIRCUITS IG A CIRCUIT O BURGLAR ALARM MUZAK 4x4 6x6 ELEC. BOX J -BOX 48" - 6" J-BOX 72" - ALARM ELECTRIC 60" - MUZAK ELECTRIC PC RACK 2x4 ELEC. BOX ELEVATION VIEW ABOVE COUNTER 36" - ELEC. 1 PC RACK 3V-COUNTER FLOOR s AlAk 41, 0 0 COUNTER CASH OFFICE PLAN VIEW P 8) EMPLOYEE LOUNGE: CONTRACTOR TO PROVIDE THREE (3) 120v/20 amp CIRCUITS. CIRCUITS TO SUPPLY THREE (3) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT). 9) MANAGER OFFICE: CONTRACTOR TO PROVIDE TWO (2) 120v/20 AMP CIRCUITS. CIRCUITS TO SUPPLY FOUR (4) NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLES (HUBBELL HBL 5352, OR EQUIVALENT) 10) BALER OR COMPACTOR: CONTRACTOR TO PROVIDE - - IF 277/480v SERVICE IS AVAILABLE - PROVIDE ONE (1) 480v/30 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 30 AMP FUSED DISCONNECT - IF 120/208v SERVICE IS AVAILABLE - PROVIDE ONE (1) 208/60 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 60 AMP FUSED DISCONNECT 11 DOC ° if a • • l!cable : CONTRACTOR TO PROVI' = ' 1) THREE PHASE D = ECT TO BE INSTALLED MINIMUM (18) EIGHTEEN INCHES A. . . E • : ' " IVING DOOR, AS DIRECTED. THE MOTOR IS MULTI TAP, ABLE TO OP =. A = - 30/3/60 OR 460/3/60, FROM THE SOURCE CIRCUIT. IF A SO " ORTH LIFT IS PRO • ' HE MOTOR SIZE ES 3.2 HP, AND IF AN ADVA IS PROVIDED THE MOTOR SIZE IS ' ', ` RE AND FUSE ACCORD ■ = " 12) DOOR BELLS: CONTRACTOR TO PROVIDE TWO (2) 24v, COMMERCIAL GRADE DOORBELLS. ONE (1) AT THE RECEIVING DOOR AND ONE (1) AT THE STOREFRONT DOORS. 13) PHONE SYSTEM: CONTRACTOR TO PROVIDE TWO (2) 120v/20amp CIRCUITS. CIRCUITS TO SUPPLY TWO (2) NEMA 5 -20R DUPLEX RECEPTACLES (HUBBELL HBL 5352 OR EQUIVALENT) WITHIN A 4" BOX (DOUBLE DUPLEX) ALL CIRCUITS TO HAVE BREAKER LOCKS. 14) LAMP WALL PLUG MOLD: CONTRACTOR TO PROVIDE TWO (2) 120V/20 AMP CIRCUITS. CIRCUITS TO SUPPLY 16' OF PLUG MOLD WITH RECEPTACLES @ 6" ON CENTER, ATTACHED TO THE WALLCASE GONDOLA @ 48" A.F.F., SWITCH REQUIRED AT PLUG MOLD LOCATION. (15) STORE LIGHTING: CONTRACTOR TO LABEL BREAKERS WITH DESCRIPTION AND AMP DRAW PER CIRCUIT. WIRING INSTRUCTIONS ARE AS FOLLOWS: CONTRACTOR TO WIRE EVERY OTHER FIXTURE AND EVERY OTHER ROW ON A SEPARATE CIRCUIT BREAKER ON SALES FLOOR AND STOCK ROOM. CIRCUIT BREAKERS ARE TO BE GROUPED BY CONTACTOR THE FOLLOWING WAY: EMPLOYEE CONTACTOR (CONTROLS ALL OFFICE, CASH, COUNT, BATHROOMS, RECEIVING AREA, AND STOCK ROOM. GROUP A 25% CONTACTOR (CONTROLS APPROXIMATELY THE NEXT 25% OF SALES FLOOR LIGHTS); GROUP B 50% CONTACTOR, (CONTROLS THE NEXT 25% OF SALES FLOOR LIGHTING); GROUP C 75% CONTACTOR, (CONTROLS THE NEXT 25% OF SALES FLOOR LIGHTING; GROUP D 100% CONTACTOR (CONTROLS THE BALANCE 25% OF SALES FLOOR LIGHTING); GROUP E CONTACTOR EXTERIOR SIGNS (CONTROLS ALL EXTERIOR BUILDING SIGNS INCLUDING PYLON SIGN). GROUP F CONTACTOR (CONTROLS ANY WALL PACK LIGHTING, PARKING LOT LIGHTING AND CANOPY LIGHTING NOT CONTROLLED BY LANDLORD). 16) DOCK LIGHT (if applicable): CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY NEMA 5 -20R GENERAL DUTY DUPLEX RECEPTACLE (HUBBELL HBL 5352, OR EQUIVALENT). SWITCH REQUIRED AT RECEPTACLE LOCATION. MOUNT RECEPTACLE /SWITCH @ 48" A.F.F. BETWEEN DOORS OR WITHIN 12" OF DOOR FRAME. 17) WATER COOLER: CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY A ELKAY MODEL EZSTL8LC HI -LO WATER COOLER MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 18) HAND DRYER: CONTRACTOR TO PROVIDE HAND DRYERS AND ONE (1) 120V/20 AMP CIRCUIT (per unit). CIRCUIT TO SUPPLY A EXCEL MODEL XL -W ELECTRIC HAND DRYER, MOUNTED PER ALL LOCAL, STATE, FEDERAL AND ADA CODES OR REGULATIONS. 19) MOTION SENSOR SWITCHES: INSTALL LEVITON ODS10 - IDW MOTION SENSOR SWITCHES AS INDICATED ON SHEET E -1. 20) DOOR KIT DISPLAY: CONTRACTOR TO PROVIDE ONE (1) 120V/20 AMP CIRCUIT. CIRCUIT TO SUPPLY ONE (1) 4x4 BOX w/TWO (2) SWITCHES. • SWITCH (A) TO SUPPLY TWO (2) 8' PLUGMOLD w /RECPTACLES @ 6" ON CENTER. • PLUGMOLD (A) TO BE LOCATED ACROSS TOP- CENTER OF GONDOLA FIXTURE. • PLUGMOLD (B) TO BE LOCATED INSIDE DOOR KIT DISPLAY, ATTACHED TO GONDOLA FIXTURE PEGBOARD @ 64" A.F.F. • SWITCH (B) TO SUPPLY TWO (2) UNDER SHELF LIGHT FIXTURES (ANTARES GT534LC-41K) MOUNTED TO UNDERSIDE NEAR THE FRONT EDGE OF THE TOP SHELF INSIDE THE DOOR KIT DISPLAY. SEPARATE PERMIT AND APPROVAL REQUIRED wd 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS. COM ISSUE DATES CLIENT REVIEW PERMIT BID CONSTRUCTION ##########t WD PROJECT NUMBER ########/# w Q ^I,TY( It - AUG 1 4 2012 PERMIT CENTER ELECTRIC NOTES W (9 0 0 LLI 0 .u) a_ a w ul 0 1- CD N (` w W o J ( TOTAL: 27,497 �L) (D m En J U (n 0 CV M co N Z WO ,- d' LlJ Z Q O zcO J Q Cn 0- m O W = M O Fro (1) O co CO co CV d C4 0 z SHEET: E -2 DEVICE SCHEDULE 1. ONE DUCT SENSOR IN THE SUPPLY AIR DUCT OF EACH RTU. 2. ONE DZC FOR EACH ROOFTOP. ONE DZC FOR ANY OTHER HVAC DEVICE (IF SPECIFIED). 3. MOUNT EM CTS ON 3 -PHASE BUSS BARS AT MDP AFTER UTILITY METER AND BEFORE TRANSFORMERS AND BRANCH CIRCUITS. 4. M.C. SHALL INSTALL LOW VOLTAGE CABLE IN RACEWAYS PROVIDED BY E.C. AND TERMINATE BOTH ENDS. - LINE VOLTAGE WIRING AND TERMINATIONS BY E.C. 5. E.C. SHALL PROVIDE AND INSTALL A DEDICATED 120V, 20A CIRCUIT TO POWER THE PIP. LABEL BREAKER EMS -2. 6. INTERCONNECTING CABLING BETWEEN THE PIP AND SLP SHALL BE INSTALLED BY THE M.C. AND THE GROUND CONNECTION BY THE E.C. 7. WITH THE EXCEPTION OF THE OSD AND ENERGY METERS THE M.C. SHALL TERMINATE ALL LV CABLES IN THE SLP. 8. E.C. SHALL PROVIDE AND INSTALL A DEDICATED 120V, 20A CIRCUIT TO POWER THE LCP. LABEL BREAKER EMS-1. 9. FOR FUTURE USE. MC PULLS WIRE THROUGH BOX/RACEWAY PROVIDED BY EC. COIL UP AND LABEL IN SLP AND COIL UP NEXT TO SECURITY PANEL. SYMBOL DEVICE QUANTITY DEVICE LOCATION DEVICE CABLE TYPE NOTES ® CARBON DIOXIDE SENSOR 1 MAIN SPACE, MOST CENTRALLY LOCATED, ABOVE/BESIDE DZC 18/2 (X2) LOAD SIDE COIL INTERLOCK RELAY ® DUCT TEMPERATURE SENSOR 1 PER ROOFTOP UNIT BOTTOM OF MAIN SUPPLY AIR DUCT DROP 18/2 1 ® DIGITAL ZONE CONTROLLER 1 PER ROOFTOP UNIT (AND ADDITIONAL HVAC) 1 PER MDP IN ZONE BEING SERVED MAIN 3 -PHASE SUPPLY NEAR UTILITY METER 18/10 24/1 P (COMM CABLE TO SLP) 2 3 Q ENERGY METER ® LIGHTING CONTROL PANEL 1 NEAR BREAKER PANELS 18/10 PLUS ALL REQ'D LINE VOLTAGE [o 1L1 is lL3 OUTSIDE SENSING DEVICE 1 ROOF 18/2 (X2) UNSHIELDED SOLID CONDUCTOR TWISTED PAIR BELDEN 1583A CAT5 POWER INTERFACE PANEL 1 ELECTRICAL ROOM (UNDER SLP) (1) 18/2, OTHER (SEE POINT TO POINT DWG'S) 5 •11% SCREAM LOGIC PANEL 1 ELECTRICAL ROOM VARIES PER CONNECTED DEVICE SECURITY INTERFACE 1 COIL WIRES NEXT TO SECURITY PANEL 18/2 (x2) INSTALLATION RESPONSIBILITIES _ SYMBOL DEVICE PROVIDED BY MOUNTING BOX/RACEWAYS TERMINATION OF WIRES AT BOTH ENDS NOTES Q CARBON DIOXIDE SENSOR SIEMENS MC EC MC ® DUCT TEMPERATURE SENSOR SIEMENS MC EC MC 1 DIGITAL ZONE CONTROLLER SIEMENS MC EC MC 2 ® ENERGY METER SIEMENS EC EC EC 3 ® LIGHTING CONTROL PANEL SIEMENS EC EC MC 4,8 OUTSIDE SENSING DEVICE SIEMENS EC EC EC V LIGHTING OVERRIDE PANEL (4 BUTTON) SIEMENS MC EC MC ® POWER INTERFACE PANEL SIEMENS EC EC EC /MC 4,5,6 SCREAM LOGIC PANEL SIEMENS EC EC EC /MC 7 SECURITY INTERFACE SIEMENS SUPPLY STARTER ILI \l12 \ b \ EC N/A 9 NOTES 1. ONE DUCT SENSOR IN THE SUPPLY AIR DUCT OF EACH RTU. 2. ONE DZC FOR EACH ROOFTOP. ONE DZC FOR ANY OTHER HVAC DEVICE (IF SPECIFIED). 3. MOUNT EM CTS ON 3 -PHASE BUSS BARS AT MDP AFTER UTILITY METER AND BEFORE TRANSFORMERS AND BRANCH CIRCUITS. 4. M.C. SHALL INSTALL LOW VOLTAGE CABLE IN RACEWAYS PROVIDED BY E.C. AND TERMINATE BOTH ENDS. - LINE VOLTAGE WIRING AND TERMINATIONS BY E.C. 5. E.C. SHALL PROVIDE AND INSTALL A DEDICATED 120V, 20A CIRCUIT TO POWER THE PIP. LABEL BREAKER EMS -2. 6. INTERCONNECTING CABLING BETWEEN THE PIP AND SLP SHALL BE INSTALLED BY THE M.C. AND THE GROUND CONNECTION BY THE E.C. 7. WITH THE EXCEPTION OF THE OSD AND ENERGY METERS THE M.C. SHALL TERMINATE ALL LV CABLES IN THE SLP. 8. E.C. SHALL PROVIDE AND INSTALL A DEDICATED 120V, 20A CIRCUIT TO POWER THE LCP. LABEL BREAKER EMS-1. 9. FOR FUTURE USE. MC PULLS WIRE THROUGH BOX/RACEWAY PROVIDED BY EC. COIL UP AND LABEL IN SLP AND COIL UP NEXT TO SECURITY PANEL. CABLE SCHEDULE CABLE SIZE TYPE MFG. /MODEL 18/2 18AWG /2- CONDUCTOR SHIELDED, STRANDED, PLENUM RATED BELDEN /6300FE NON - PAIRED COMTRAN /3644 TAPPAN /1880AB2M -CMP FAN l LOAD SIDE COIL INTERLOCK RELAY EXHAUST FAN STARTER CONTACTOR - - 18/10 18AWG /10- CONDUCTOR UNSHIELDED, STRANDED, PLENUM BELDEN /6308UE NON - PAIRED LAKE CABLE /P1810C -WIN TAPPAN /1880AB10 -CMP CONTACTOR - - - 24/1P 24AWG /1- TWISTED PAIR SHIELDED, STRANDED, PLENUM RATED, TWISTED PAIR BELDIN/82841 PAIRED LAKE CABLE /PF242CS TAPPAN /2469ATIM -CMP [o 1L1 is lL3 CAT5 24AWG/ 4 -UTP UNSHIELDED SOLID CONDUCTOR TWISTED PAIR BELDEN 1583A CAT5 GENERAL EMS CONSTRUCTION NOTES: THE MECHANICAL CONTRACTOR SHALL PROVIDE THE INSTALLATION LABOR AND MATERIALS TO INSTALL THE LOW VOLTAGE PORTION OF THE CUSTOMER SUPPLIED EMS SYSTEM ACCORDING THE EMS SCHEDULES AND THE FOLLOWING: I. INSTALL EMS DEVICES AT LOCATIONS SHOWN ON THE MECHANICAL DRAWINGS AND MOUNT ACCORDING TO THE EMS DETAILS. q. PROVIDE AND INSTALL THE LOW VOLTAGE CABLING FROM THE EMS DEVICES TO THE RTU'S, SLP, AND LCP III. TERMINATE THE LOW VOLTAGE CABLING AT BOTH ENDS. IV. CLEARLY IDENTIFY (LABEL) THE CABLES AT BOTH ENDS. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE INSTALLATION LABOR AND MATERIALS TO INSTALL THE LINE VOLTAGE PORTION OF THE CUSTOMER SUPPLIED EMS SYSTEM ACCORDING THE EMS SCHEDULES AND THE FOLLOWING: I. PROVIDE AND INSTALL ELECTRICAL BOXES WITH 3/4" EMT STUB -UPS TO ABOVE CEILING GRID FOR WALL MOUNTED EMS AND CONTROL DEVICES. 11. MOUNT EMS PANELS AND PIPE TOGETHER ACCORDING TO THE EMS DRAWINGS. III. INSTALL THE ENERGY METER AT THE MAIN DISTRIBUTION PANEL. INSTALL AND TERMINATE COMMUNICATIONS CABLE. IV. PROVIDE AND INSTALL AN 8' SECTION OF 1/2" RIGID FOR ROOF MOUNTED OSD. INSTALL AND TERMINATE OSD AND CABLE. V. PROVIDE AND INSTALL (1) EACH 120V, 20A CIRCUIT TO POWER THE PIP. LABEL PIP BREAKER "EMS -2" 3. ALL WIRING SHALL CONFORM TO NATIONAL AND STATE ELECTRICAL CODES. 4. NOTES ABOVE DO NOT ALLEVIATE CONTRACTORS OF OVERALL RESPONSIBILITIES OF PROVIDING A COMPLETE AND OPERATIONAL SYSTEM. INSTALLATION SUMMARY 1. LOW VOLTAGE CABLE I. THE M.C. SHALL FURNISH THE LOW VOLTAGE CABLE FOR THE EMS SYSTEM. THE CABLE SHALL BE AS SPECIFIED IN THE CABLE SCHEDULE. 2. EQUIPMENT DELIVERY L SIEMENS SHALL PROVIDE THE EMS EQUIPMENT IN 1 SHIPMENT. II. IT SHALL BE UP TO THE G.C. TO CALL FOR EMS EQUIPMENT DELIVERY THE EQUIPMENT WILL BE SHIPPED WITHIN 2 DAYS OF RECEIVING A VALID REQUEST. A VALID REQUEST SHALL CONSIST OF THE FOLLOWING: 1 -NAME AND PHONE NUMBER OF PERSON RESPONSIBLE FOR RECEIVING THE EMS EQUIPMENT AND STORE NUMBER 2 -A VALID SHIPPING ADDRESS (CONFIRMABLE BY THE DELIVERY AGENT). 3. CONTACT INFORMATION I. PLEASE DIRECT ALL SHIPPING REQUESTS TO SIEMENS AT (512) 306 -9400 4. EMS COMMISSIONING I. IT SHALL BE UP TO THE G.C. TO CALL FOR EMS COMMISSIONING AT LEAST 2 WEEKS PRIOR TO TURN OVER AND BEFORE THE INSTALLING CONTRACTOR HAS LEFT THE PROJECT. a. SIEMENS WILL COMMISSION THE EMS SYSTEM UPON RECEIVING A VALID REQUEST AND AFTER THE FOLLOWING CONDITIONS HAVE BEEN MET: 1 -ALL EMS DEVICES AND PANELS HAVE BEEN INSTALLED, WIRED AND TERMINATED 2 -ALL LINE VOLTAGE WIRING HAS BEEN COMPLETED 3 -ALL CONTROLLED EQUIPMENT HAS BEEN INSTALLED AND STARTED II. FAILURE TO MEET THESE CONDITIONS COULD RESULT IN DELAY OF STORE OPENING GENERAL LV CABLE INSTALLATION INSTRUCTIONS 1. HOME RUNS I. LOW VOLTAGES CABLES SHALL BE PULLED FROM DEVICE TO CONTROL PANEL WITHOUT SPLICING. 2. COMMUNICATIONS CABLING I. IN THE CASE OF MULTIPLE DEVICES SUCH AS COMMUNICATIONS CABLING, THE CABLE SEGMENTS SHALL BE PULLED FROM DEVICE TO DEVICE WITHOUT SPLICING. 3. CABLE SHIELD GROUNDING 1. EACH CABLE RUN SHALL BE GROUNDED AT ONE END ONLY. GROUND SHIELD DRAIN WIRE AT CONTROL PANEL END. FASTEN DRAIN WIRE TO EARTH GROUND SCREWS PROVIDED. THE THE SHIELD AND DRAIN WIRE SHALL BE REMOVED FROM THE OPPOSITE (DEVICE) END AND ISOLATED FROM GROUND. II. IN THE CASE OF MULTIPLE DEVICES SUCH AS COMMUNICATIONS WIRING, THE SHIELD DRAIN WIRES AT THE INTERMEDIATE DEVICES SHALL BE MECHANICALLY SPLICED TOGETHER AND ISOLATED FROM GROUND. 4. TESTING SHIELD GROUNDS L DURING COMMISSIONING THE FIELD SERVICE REPRESENTATIVE (FSR) WILL TEST THE SHIELD GROUNDING AT THE CONTROL PANEL. SHIELDS FOUND TO HAVE CONTINUITY LESS THEN 100K OHM TO GROUND SHALL BE REJECTED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEARING SHIELD GROUND FAULTS. GENERAL NON -EMS CONTROLS NOTES: 1. COMBUSTION AIR VENTILATION AND OTHER EQUIPMENT I. CONTROLS FOR COMBUSTION AIR VENTILATION AND ANY OTHER EQUIPMENT NOT SPECIFICALLY MENTIONED IN THE EMS SCHEDULES SHALL BE FURNISHED AND INSTALLED ACCORDING TO THE MECHANICAL AND ELECTRICAL BID DOCUMENTS. 2. EXHAUST FAN, TRANSFER FAN AND OTHER "HARD- WIRED" INTERLOCKS (SEE INTERLOCK EXAMPLE BELOW) I. WHEN HARD -WIRED INTERLOCKING IS SPECIFIED IN THE MECHANICAL AND /OR ELECTRICAL SCHEDULES, THE INTERLOCKS SHALL BE FURNISHED AND INSTALLED BY THE TRADES SPECIFIED. INTERLOCKING IS NOT PART OF II. WHERE EXHAUST FAN AND RTU INTERLOCKS ARE CALLED OUT, THE CONTRACTOR SHALL CONNECT DIRECTLY TO THE SUPPLY FAN CONTACTOR COIL AND WIRE IN PARALLEL TO THE COIL OF A PROPERLY SIZED CONTACTOR OR STARTER SERVING THE INTERLOCKED EQUIPMENT. DO NOT USE THE EMS SYSTEM TO INTERLOCK EQUIPMENT. 3. LIFE SAFETY AND FIRE ALARM SYSTEMS I. LIFE SAFETY AND FIRE ALARM SYSTEMS ARE NOT PART OF THE EMS SYSTEM AND SHALL BE FURNISHED AND INSTALLED AS SPECIFIED IN THE MECHANICAL AND ELECTRICAL BID DOCUMENTS. II. MECHANICAL EQUIPMENT SHUTDOWN SHALL BE WIRED AS TO NOT AFFECT THE EMS SYSTEM. 4. MANUFACTURER SUPPLIED HUMIDITY CONTROLLERS I. DEHUMIDIFYING ROOFTOP UNITS a. SOME ROOFTOP UNITS MAY COME EQUIPPED WITH A DEHUMIDIFICATION CYCLE AND SPACE HUMIDITY SENSOR. THIS SENSOR SHALL BE INSTALLED IN ADDITION TO THE EMS SYSTEM AND ACCORDING TO THE MANUFACTURER'S INSTRUCTION. 19_,.........2_451 EXAMPLES FOR 3 -PHASE EQUIPMENT INTERLOCKING RTU SUPPLY STARTER 1 112 1 FAN PARALLEL COILS INTERLOCK RELAY EXHAUST FAN STARTER RTU SUPPLY STARTER lu FAN l LOAD SIDE COIL INTERLOCK RELAY EXHAUST FAN STARTER CONTACTOR - - - OO CONTACTOR - - - 1© T� lu lu lu 0 [o 1L1 is lL3 ©- _ - CONTACTOR ® CONTACTOR OVERLOAD MODULE it ° sa OVERLOAD MODULE sa ` n 12 73 11 12 w T3 OVERLOAD MODULE OVERLOAD MODULE in n A u RTU SUPPLY STARTER 41:.1 112 1L3 FAN CURRENT SWITCH INTERLOCK CT SWITCH EXHAUST FAN STARTER RTU SUPPLY STARTER ILI \l12 \ b \ 1L3 \ b FAN AUXILIARY CONTACT INTERLOCK AUXILIARY CONTACT EXHAUST FAN STARTER I CONTACTOR - = - _ CONTACTOR © 1 T 1" lI2 l� - _ - © lu lu lu \ - CONTACTOR - - CONTACTOR OVERLOAD MODULE !e° A` si © - - OVERLOAD MODULE :R` sa : ©_ T1 72 13 71 12 %ma; © 73 ® d` OVERLOAD MODULE e` tot OVERLOAD MODULE 11 72 13 11 12 0 TS MULTIPLE SEGMENT EXAMPLE GROUND SHIELD AT CONTROL PANEL END ONLY. USE GROUNDING LUGS OR TERMINALS PROVIDED. CONTROL PANEL INTERMEDIATE DEVICE LAST DEVICE MECHANICALLY SPLICE SHIELD DRAIN WIRES TOGETHER AT INTERMEDIATE DEVICES AND ISOLATE FROM GROUND. CUT OFF DRAIN WIRE AND SHIELD. APPLY ELECTRICAL TAPE TO ISOLATE FROM. GROUND. SEPARATE PERMIT AND APPROVAL as}'� Ge CITY OF ?II,'°_''. AUG 1.4 2012 PERMIT C EMS NOTES " Y r 7 _ ,. p Imp or Wd 7007 DISCOVERY BLVD DUBLIN, ON 43017 8141234.7000 r WDPARTNERS.COM ISSUE DATES CLIENT REVIEW ####### ### PERMIT ##### # # # ## BID ##### # ### #. CONSTRUCTION ### # # # # # ## WD PROJECT NUMBER # # ### # ### z O w cc w 1- a 0- CC CC W 0- Z W W a Z W W o a. = < (f) Q0Q 0 - c° W 0 0 0 LL. W z 0 W 0 O CDw N W -J 07 (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 N u) CD DRAWN BY W J U co • 0 o N Z LU M °o 0 r CO CO OZOCON Z - Q VJ T 0 LIJ W CC o D Z CS 0 - 0 cD W co a_ NTER SHEET: E -3 ROOF -LINE RTU ITHERMOSTAT IN TERMINAL BOARD RTU ITHERMOSTAT IN TERMINAL BOARD MOUNT OUTSIDE AIR —` DEVICE ON ROOF SD FOR NON -MALL LOCATIONS 18/2 x2 RETURN AIR DUCT 18/10 —ma SUPPLY AIR DUCT X18/2 Return/'� Air Duct 18/10 -0 L1 L2 EM L3 ELECTRIC MAINS 3 AT MOP 485 COMM LINK COMM LINK 24/1P Supply Air Duct 18/2 COMM LINK —24/1 P m -18/2 x2 CAT -5 AS REQUIRED SINGLE LINE DIAGRAM NO SCALE 24/1P SLP 0000 (1)UPS CABLES (3)18/2 (1)GND 120VAC POWER DEDICATED CIRCUIT (LABEL EMS -2) 111 PIP (1) 18/10 (1) 18/4 LCP AS REQUIRED 11! ALL CONTROLLED CIRCUITS (LINE & LOAD) 120VAC POWER, DEDICATED CIRCUIT (LABEL EMS1) PLUS ALL SWITCHED LOADS 18/2X2 --co SECURITY PANEL CUSTOMER NETWORK OR CELL MODEM KEYED NOTES O O O REFER TO DETAIL OSD 1 FOR MOUNTING AND WIRING INSTRUCTIONS. OPTIONAL RELAY ISOLATION BOARD REQUIRED IF ISOLATION RELAYS ARE NOT PROVIDED BY THE MANUFACTURER. REFER TO ENERGY METER WIRING DETAILS. SECURITY SYSTEM MUST PROVIDE DRY CONTACT CLOSURE(S) AS REQUIRED (REFER TO SLP FIELD WIRING FOR DETAILS). 1 -1/2" EMT -� 18" 75" AFF CONTROL PANEL MOUNTING DETAIL NO SCALE KEYED NOTES 1 MAXIMUM FLOOR TO TOP OF ANY PANEL 75 ". PANELS MAY BE LOWERED TO MEET EXISTING CONDITIONS. OMAXIMUM DISTANCE BETWEEN SLP AND PIP 6" TO ACCOMMODATE INTERCONNECTING CABLING. NO LESS THAN 1 -1/2" (THIS SIZE IS CRITICAL) 4 EMT SIZES SHOWN FOR LOW VOLTAGE CABLE ONLY R Y1 C Y2 FAN W1 Cc W2 R1 W3 C1 GND CO2 DN ND UP DTS RTN ND LINE A TS■•WH GND ND—BLK LINE B DZC TO SPACE TEMP SENSOR NO SCALE (OPEN VIEW) R Y1 C Y2 FAN W1 CC W2 R1 W3 Cl GND CO2 DN GN0 UP TS—WH RTN ND—BLK LINE ZTS GND CND LINE B • DZC TO DUCT TEMP. SENSOR NO SCALE OPTIONAL AS SPECIFIED BY MECHANICAL DWGS 0 + -10V OUTPUT CO2 SENSOR SIGNAL GROUND 4.20mA OUTPUT z 0- V O 4 O 0 Z U Z 0 Q Q <D D W W W O 0 o `r Q [L D= Z Z ©�1�©11©©N INSTALL RESISTOR (OPEN VIEW) R •WH 0■BLK FAN CC R1 C1 CO2 -WH ND-BLK DTS ND TS ND Y1 Y2 W1 W2 W3 GND DN UP RTN LINE A GND LINE B 18/2 CABLE X2 DZC TO CO2 SENSOR WIRING DETAILS NO SCALE 0 W 0 7 U 0 N W 0 0 U RTU F 0 z 00 Z LL 0 01 Z 0 0 U 1ok1>-- ;: ol���� z 7 F z 0 0 J = W CC W (OPEN VIEW) c � R— REDvYEL —Y1 0— BLKvBLU —Y2 FAN rWHT --W1 OCO■PURy$RN •W2 R1 W3 C1 ■GRN ■GND CO2 DN GND UP DTS RTN GND LINEA ZTS GND GND LINE B // DZC TO ROOFTOP WIRING DETAIL NO SCALE 18/2 CABLE (X2) TERMINALS ON I/O MODULE IN SLP IN SLP 1a 1 1b 1- BUTTON OVERRIDE NEAR SECURITY KEYPAD AT FRONT DOOR (REAR VIEW) SW 1 la 1b TYPICAL OF 3 CONNECTIONS 1- COMMON, 2 SWITCHED LEGS (SEE EMS POINT TO POINT DWGS) KEY SWITCH PANEL NO SCALE FOR NON -MALL LOCATIONS OUTSIDE SENSOR DEVICE (ON ROOF) OUTSIDE LIGHT SENSOR (OL)� BLK WHT BLK WHT 18/2 CABLE (X2) LOCATED IN SLP +OA -OA /OL +OL WHT BLK /BLK WHT O O O O O OUTSIDE AIR TEMPERATURE SENSOR (OA) OS� OUTSIDE SENSING DEVICE MOUNTING AND WIRING DETAILS NO SCALE POINT OUTSIDE LIGHT SENSOR, NORTH e 8' 0 0 0 0 0 0 1 ROOF LINE 1/2" RIGID CONDUIT SECURE TO BUILDING STRUCTURE UNIT HEATER WIRING DIAGRAM ELECTRIC /GAS HEATER WITH 24VAC XMFR AND THERMOSTAT INTERFACE 24VAC+ 24VAC 18/2 —4>D 0 0 0 0 0 0 0 0 Y2 1 Gam` Y2 FAN W1 OCC W2 R1 W3 C1 GND CO2 DN GND- UP DTS RTN GND ALINE A ZTS GND GND i–LINE B 0 0 0 0 0 0 0 0 0 WIRE N.O. CONTACTS WHERE THERMOSTAT CONNECTION IS INDICATED, REFER TO MF. DWG'S. W1 .—+ WHT - BLK RS 485 COMMUNICATION CABLES, USE SHIELDED 24/2 CABLE .—+ WHT - BLK FROM LAST DEVICE TO NEXT DEVICE JOIN SHIELD DRAIN WIRES AND ISOLATE FROM GROUND 18/2 24VAC- Q SPLICING BOX MAIN DISTRIBUTION PANEL ENERGY METER ADDRESS 32 1 1 • 2 2Q 4 3O 8 4IIE] 16 5p 32 6� ON 24/1P COM CABLE PLENUM RATED — TERMINALS IN SLP RS485+ RS485- ENERGY METER INSTALLATION DETAILS NO SCALE 18/2 SHIELDED RATE FOR 600V MOVE SWITCH #32 TO "ON" POSITION KEYED NOTES 0 WHEN TRANSITION FROM 18/2 TO 24/2 CAN'T BE AVOIDED THE FOLLOWING PRECAUTIONS MUST BE TAKEN: I. MOUNT A SPLICING BOX NEAR TO THE MDP. II.TERMINATE WIRES WITH SEALANT FILLED CONNECTORS (DOLPHINS OR SIMILAR) III.OBSERVE POLARITY GENERAL NOTES: 1. INSTALL ENERGY METER AT MDP AFTER UTILITY METER AND BEFORE TRANSFORMERS AND BRANCH CIRCUITS TO CAPTURE TOTAL BUILDING LOAD. 2. AVOID SPLICING THE 600V RATED COMM CABLE, IF LONG ENOUGH TO REACH SLP. MOUNTING THE ENERGY METER AT THE MDP B► • • BLACK LEAD LED FLASHES GREEN WHEN PROPERLY INSTALLED FUSE FUSE FUSE BLACK RED YELLOW PHASE VOLTAGE SENSING LEADS WITH CTS (TYPICAL) BLACK CT BLACK CT RED CT YELLOW CT RS485toSLP SEPARAT PERMIT A wzi 7007 DISCOVERY BLVD DUBLIN. OH 43017 614.634.7000 T WDPARTNERS. COM ISSUE DATE' CLIENT REVIEW # ### ####4 PERMIT 4444 ####1 BID 4444 ###41 CONSTRUCTION # ### ####t WD PROJECT NUMBER ######### g I'; I.>49sr';.) C iTY Or ",.ri; 1. ` AUG 14 2012 PERMIT CENTER z O w cc w 0 a cc � �•• I.J. I- 0 Z cc W ovcz co WLU00 D = < CD (0 <0< F— � O CC co 00 CL SQUARE FOOTAGE CO cD N W J 0) (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 DATE DRAW N co DRAWN BY w J 0 C C C C U o co Z 0 �00 W U5 0 °<Qt CC 0 Ozcc O I�-/�V — Z `^ - J Q c J CO LU _Icca..Dz J �t002 0 at] o_ EMS SPECIFICATIONo� REQUIRED SHEET: E- KEYED NOTES: OEXISTING RTU SHALL BE REUSED. MODIFY DUCT AS SHOWN OR CONNECT TO CONCENTRIC DIFFUSER. VERIFY EXACT LOCATION. 0 EXISTING SMOKE DETECTORS TO BE REUSED. VERIFY FUNCTIONALITY. REPLACE ANY SMOKE DETECTORS NOT FUNCTIONING PROPERLY. 0 EXISTING RESTROOM AND JANITOR ROOM TO REMAIN. CLEAN ALL FIXTURES AND LEAVE IN LIKE NEW CONDITION. REPLACE AS NECESSARY. 0 EXISTING GAS METER AND ALL EXISTING PIPING TO REMAIN. VERIFY CONDITION OF METER, CHECK CONNECTIONS FOR LEAKS AND REPLACE AS NECESSARY. EXISTING DUCT TO REMAIN. REBALANCE DIFFUSERS AS SHOWN. (TYP) EXISTING RESTROOM EXHAUST FAN SHALL BE REUSED. REUSE EXISTING CONTROLS. VERIFY EXACT LOCATION OF EXHAUST FAN. NEW DZC TEMPERATURE SENSOR TO BE MOUNTED AT 60" A.F.F. SEE SHEET E -4 FOR MORE INFORMATION. OCONNECT NEW DIFFUSER INTO EXISTING DUCT. MODIFY DUCT AS NECESSARY FOR NEW CONNECTION. NEW CONCENTRIC DIFFUSER. MAKE CONNECTION FROM DUCT TO DIFFUSER WITH FL DU JUS - ATT OR THR UNTI ' IFOR N. j Q CONNECT NEW 6" EXHAUST DUCT INTO EXISTING EXHAUST DUCTWORK. BALANCE SYSTEM FOR AIR FLOWS SHOWN ON PLAN. ES. M -2 NOTE TO MECHANICAL CONTRACTOR: ANY HVAC EQUIPMENT NOTED TO BE NEW OR REPLACED, WILL BE SUPPLIED BY BIG LOTS - CONTACT TOM THOMAS FOR SPECIFIC EQUIPMENT LISTING. ALL OTHER HVAC EQUIPMENT TO BE VERIFIED AS EXISTING AND TO BE PUT INTO GOOD WORKING CONDITION. THIS MAY BE A REQUIREMENT OF THE LEASE AS A LANDLORD RESPONSIBILITY. ±2560 MBH —G BIG LOTS LOAD ^. (E)UH, (E)16" (E)SD (E)SD 1250 1250 oz RTU #7 12" (E)SD 1.250 I A (E)SD 1250 (TYP) #27 )RTU #2 (E) RTU #2 l� z r O7 RTU #1 DZ 1•l SD -1 100 a (E)SD 71250 ir(E)16" SD -1 530 (E)20" 0 (E) RTU #70 (E)16" 11 E(E)RG (E) RTU #4 O 1 (E)20" (E)RG il(E)SD 1250 (E) RG DZ RTU #4O (TYP) 7 (E)SD 1250 E)16" (E)16" (E)SD 1250 1250 (E)SD (E)SD ¶1250 1250 1/E)16" (E) RTU #3 E 1 ? (TYP) (E)20" 'j' (E)20" • ■ li-(E)16" (E)SD 1250 (E)RG RTU #3 (E)RG ii-(E)16" (E)16" (E)SD 1250 0 E)14" (E)SD 1350 E)16" r(E)16" (E)SD 1350 (E)RG 0 0 0 (E)SD 1400 (E)16" T 1(E)16" E)SD 1400 WI ( (E)SD 1000 24x18 SD -1 340 !�l (E)SD 1000 (E)14" SD -1 10" 340 SD -1 10" 340 II1 SD -1 340 �wl SD -1 340 10" 0 co (E)SD 1000 0 O 18x12 10" SD -1 340 N 0 N 16x12 SEPARATE PERMIT AND APPROVAL REQUIRED 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW ####### # ## PERMIT ########## BID ########## CONSTRUCTION ####### ### 200 rzzrizzA Ty oF AUG 14 2012 PERMIT CENTER MECHANICAL PLAN Z 0 w cc w 0 5. rr W w co CC Z W LLI co D =Q rQOQ ( co Y O 0 Lu cc D 0 can z w 0 I- 0 w 0 w OC O 1- CO z O D N CD U) w L U !J Z V J TOTAL: 27,497 N z 0 C w 3/32" = 1' -0" UQ Z QW m0 w Oz Q W fO CC O E8 U) 00 N N M _O CC 0 D /J CO LL D O J co �U SHEET: M -1 HVAC LEGEND GENERAL SD -1 r TYPE DIFFUSER DESIGNATION 300 r CFM MANUAL VOLUME DAMPER VD TV TURNING VANE '`,e TO THERMOSTAT Y■: DIGITAL ZONE CONTROL NEW DUCTWORK BY HVAC CONTRACTOR POINT OF ATTACHMENT TO EXISTING Oil SUPPLY AIR RETURN AIR EXHAUST FAN es 1 DUCT TRANSITION OR TAKEOFF (E) EXISTING R RELOCATE EXISTING DUCTWORK TO REMAIN SD DUCT SMOKE DETECTOR ® REMOTE TEST STATION GAS UNIT HEATER r� FLEXIBLE CONNECTION 1 TRANSFER GRILLE F.- SIDEWALL REGISTER ±2560 MBH —G BIG LOTS LOAD ^. (E)UH, (E)16" (E)SD (E)SD 1250 1250 oz RTU #7 12" (E)SD 1.250 I A (E)SD 1250 (TYP) #27 )RTU #2 (E) RTU #2 l� z r O7 RTU #1 DZ 1•l SD -1 100 a (E)SD 71250 ir(E)16" SD -1 530 (E)20" 0 (E) RTU #70 (E)16" 11 E(E)RG (E) RTU #4 O 1 (E)20" (E)RG il(E)SD 1250 (E) RG DZ RTU #4O (TYP) 7 (E)SD 1250 E)16" (E)16" (E)SD 1250 1250 (E)SD (E)SD ¶1250 1250 1/E)16" (E) RTU #3 E 1 ? (TYP) (E)20" 'j' (E)20" • ■ li-(E)16" (E)SD 1250 (E)RG RTU #3 (E)RG ii-(E)16" (E)16" (E)SD 1250 0 E)14" (E)SD 1350 E)16" r(E)16" (E)SD 1350 (E)RG 0 0 0 (E)SD 1400 (E)16" T 1(E)16" E)SD 1400 WI ( (E)SD 1000 24x18 SD -1 340 !�l (E)SD 1000 (E)14" SD -1 10" 340 SD -1 10" 340 II1 SD -1 340 �wl SD -1 340 10" 0 co (E)SD 1000 0 O 18x12 10" SD -1 340 N 0 N 16x12 SEPARATE PERMIT AND APPROVAL REQUIRED 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW ####### # ## PERMIT ########## BID ########## CONSTRUCTION ####### ### 200 rzzrizzA Ty oF AUG 14 2012 PERMIT CENTER MECHANICAL PLAN Z 0 w cc w 0 5. rr W w co CC Z W LLI co D =Q rQOQ ( co Y O 0 Lu cc D 0 can z w 0 I- 0 w 0 w OC O 1- CO z O D N CD U) w L U !J Z V J TOTAL: 27,497 N z 0 C w 3/32" = 1' -0" UQ Z QW m0 w Oz Q W fO CC O E8 U) 00 N N M _O CC 0 D /J CO LL D O J co �U SHEET: M -1 DIVISION 15 - MECHANICAL BASIC MECHANICAL REQUIREMENTS A. NOTE 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE ON THE MECHANICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS. EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR BIG LOTS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE G.C. CONSTRUCTION MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. ALL OF THE EXISTING EQUIPMENT IS TO BE CLEANED, AND SURVEYED FOR OPERATION AND A COPY OF THIS SURVEY SHALL BE SENT TO BIG LOTS TEN DAYS BEFORE THE FINAL INSPECTION. ANY REPAIRS THAT NEED TO BE MADE NEED TO BE QUOTED AND SENT WITH THE SURVEY ALL OF THE REPAIRS WILL BE MADE UNDER A CHANGE ORDER. 8. THE HVAC CONTRACTOR WILL BE RESPONSIBLE TO CHANGE ALL AIR FILTERS AND CLEAN ALL OF THE CONDENSER COILS, EVAPORATOR COILS, AND RETURN AIR CHAMBERS OF THE EQUIPMENT TEN DAYS BEFORE THE SOFT OPENING OF THIS STORE. THIS DATE WILL BE SPECIFIED IN THE LETTER OF AGREEMENT ATTACHED TO THE CONTRACT DOCUMENT. 9. ALL OF THE WORK MUST BE COMPLETED TEN DAYS BEFORE THE SOFT OPENING OF THIS STORE. INCLUDING ALL FINAL INSPECTIONS, LIFE SAFETY, AND FIRE MARSHALL VISIT. C. 00DES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY BIG LOTS TO THE CONTRACTOR. D. LICENSES. PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. 2. FURNISH TO G.C.'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT E. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. ANY PROPOSED SUBSTITUTIONS MUST BE PRE - QUALIFIED, LISTED IN THIS CONTRACTORS BID AND HAVE A COST SAVINGS FOR BIG LOTS OF AT LEAST $500 PER TYPE OF EQUIPMENT. ADDITIONALLY, ONLY MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE REVIEWED. ALL SUBSTITUTIONS ARE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWINGS PROCESS, BY BIG LOTS HVAC REPRESENTATIVE PRIOR TO ACCEPTANCE. BIG LOTS RESERVES THE RIGHT TO REJECT ANY PROPOSED SUBSTITUTIONS. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. MECHANICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO BIG LOTS HVAC REPRESENTATIVE FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR BIG LOTS HVAC REPRESENTATIVE REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOBS PROGRESS. SUBMITTALS SHALL BEAR THE SIGNATURE OF BIG LOTS HVAC REP. AND THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. F. GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK. MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY G.C.'S CONSTRUCTION MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. THIS CONTRACTOR SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY THIS CONTRACTOR AND G.C.'S VENDORS. THIS CONTRACTOR. SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. G. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE STAMPED "DO NOT REMOVE" AND PLACED IN DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANELS. H. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE G.C.'S CONSTRUCTION MANAGER, IN WRITING OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF HID. OTHERWISE, G.C. CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. I. PHASING REQUIREMENTS 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE WITH G.C.'S CONSTRUCTION MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC. PLUMBING OR FIRE PROTECTION SYSTEMS. J. DEMOLITION 1 THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY G.C.. COORDINATE WITH G.C. ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH G.C. FOR THE REMOVAL OF ALL EXISTING ARE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH G.C. PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY G.C. K. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH ITS RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS. THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. L. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO BAR JOIST EVERY 4' WITH 1" GALVANIZED STRAP WRAPPED AROUND BAR JOIST WITH AT LEAST (2) #8 SHEET METAL SCREWS ON EACH SIDE. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. DIVISION 15 - MECHANICAL SECTION 15500 HEATING, CONDITIONING EAT NG, VENTILATION, AND AIR CO A. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING,INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. HVAC UNITS, EQUIPMENT, AND APPURTENANCES UNLESS NOTED OTHERWISE). B. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. C. CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). D. CONDENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). E. TESTING, ADJUSTING, AND BALANCING. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY G.C. AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS AND SCHEDULES FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. EQUIPMENT SHALL BE INSTALLED AND START -UP PERFORMED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY G.C.. SIGNIFICANT DEVIATIONS IN ROUTING OR SIZING OF THE DUCTWORK/PIPING SYSTEMS MUST BE CLOUDED AND NOTED ON THE SHOP DRAWINGS. THESE SIGNIFICANT DEVIATIONS MUST BE APPROVED BY BIG LOTS ENGINEER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDITION. WHERE OTHER CODES ARE ENFORCED, (IE. UMC, BOCA, ETC.) USE THE MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS: 2" W.G., POSITIVE RETURN AND EXHAUST DUCTS: 2" W.G., NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS: SUPPLY DUCTS CLASS B - 3" W.G. RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 4. MEDIUM PRESSURE DUCT A. WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 4 INCHES WATER COLUMN MINIMUM OR GREATER AS REQUIRED BY LANDLORD. B. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. C. CONNECTION TO THE LANDLORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WITH "LO- LOSS" SADDLE TEE TAPS BY UNITED MCGILL CORP., OR AS OTHERWISE REQUIRED BY THE LANDLORD. D. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION, WITH THE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT LINED. 5. ROUND AND FLAT OVAL DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM CONSTRUCTION, ROUND DUCTWORK SIZES 12" DIAMETER AND SMALLER IN CONCEALED AREAS MAY BE SNAP -LOCK CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. DUCT AND FITTINGS SHALL BE G90 GALVANIZED STEEL CONFORMING TO ASTM A-653 AND A -924. ALL FITTINGS THAT ARE SPOT WELDED OR BUTTON PUNCHED CONSTRUCTION SHALL BE INTERNALLY SEALED. 6. AS A MINIMUM, CROSS BREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8" WIDE X 3/16" DEEP ON 12" CENTERS TO PREVENT VIBRATIONS, REGARDLESS OF DUCT GAUGE. 7. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL 90 DEGREE ELBOWS OVER 36" IN LENGTH. INSTALL SINGLE THICKNESS TURNING VANES IN ALL OTHER ELBOWS. TURNING VANES NOT REQUIRED IN RADIUS TYPE ELBOWS. 8. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES. 9. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 112 "X1 -1/2" X1 /8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 10. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER- FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. NOTE: LINDAB FACTORY GASKETED JOINTS DO NOT REQUIRE ADDITIONAL SEALER. 11. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 12. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 13. PROVIDE ACCESS TO ALL MOTORIZED ZONE DAMPERS, FIRE DAMPERS. CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY G.C.'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3' -0" OF DEVICE. 14. DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS UNLESS NOTED ON DRAWINGS. WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO DETAILS. 15. N/A D. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ROOFTOP UNITS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE- COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. E. VIBRATION ISOLATION DEVICES 1. VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND STRUCTURE. THE BID. 2. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 3. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITION WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING.AVOID TWO "GROUNDING " THE ISOLATOR. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 5. CONSULT MANUFACTURER FOR APPLICATION DATA. F. FLEXIBLE AIR DUCT 1. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS. FLEXIBLE AIR DUCT MAY ONLY BE USED IN CONCEALED VERTICAL APPLICATIONS WITHOUT PRIOR APPROVAL FROM G.C.'S CONSTRUCTION MANAGER UNLESS NOTED OTHERWISE. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 14' -0" IN LENGTH AT ANY ONE LOCATION. G. MANUAL DAMPERS 1. FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. H. FIRE DAMPERS & SMOKE FIRE DAMPERS 1. FIRE DAMPERS SHALL BE RUSKIN MODEL NO. FD36, FD6OFA OR FDR25. 2. PROVIDE FIRE DAMPERS WITH ACCESS DOORS INSTALLED WHERE REQUIRED BY ALL LOCAL CODES. 3. COMBINATION SMOKE FIRE DAMPERS SHALL BE RUSKIN MODEL NO. FSD36, FSD6OFA, OR FSDR25. I. DUCTWORK INSULATION 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH 2. DUCTWORK SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INCREASE DUCTWORK SIZES AS REQUIRED FOR INTERNALLY LINED DUCT TO MAINTAIN INSIDE CLEAR DIMENSIONS. 3. INSULATE ALL OF THE FOLLOWING DUCTWORK: CONCEALED SUPPLY DUCTWORK THAT IS NOT INTERNALLY LINED UNTREATED OUTSIDE AIR DUCTWORK LOCATED WITHIN THE INTERIOR SPACE SUPPLY & RETURN DUCTWORK INSULATION SHALL BE2" REINFORCED FOIL FACED, VAPOR SEALED FIBREGLASS. INSTALLED THERMAL RESISTANCE SHALL BE AT LEAST 6.0 FOR INTERIOR DUCTWORK AND 8.0 FOR EXTERIOR DUCTWORK, OR AS REQUIRED BY LOCAL CODES. PROVIDE EXTERIOR DUCTWORK INSULATION WITH WEATHERPROOF JACKETING WHEN APPLICABLE. LINER MAY BE USED IN LIEU OF FIBERGLASS WRAP. 4. ALL INSULATION AND LINING SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. J. CURBS AND STEEL FRAMING FOR SUPPORT 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS AND BLOCKING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" HIGH OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. UNLESS NOTED OTHERWISE. INSULATE UNDER THE COMPRESSOR SECTION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. COORDINATE STEEL FRAMING REQUIREMENTS, ROOF PENETRATIONS, AND ROOF FLASHING WITH G.C. TO DETERMINE SCOPE OF WORK PRIOR TO BID. THIS CONTRACTOR MUST RECEIVE WRITTEN APPROVAL BEFORE ANY ADDITIONAL WORK TAKES PLACE. 2. WHEN APPLICABLE THE HVAC CONTRACTOR IS RESPONSIBLE TO GET THIS DRAWING STAMPED BY A MECHANICAL ENGINEER AND HAVE A STRUCTURAL STUDY OF THE ROOF STRUCTURE, OF THE SITE, FOR PROPER SUPPORT OF THE UNITS BY A STRUCTURAL ENGINEER, THIS IS TO BE SUBMITTED TO BIG LOTS IN WRITING BEFORE ANY WORK STARTS. ALL OF ROOFTOP PENETRATIONS TO BE FRAMED WITH 2.5" ANGLE IRON ON ALL SIDES, AT LEAST .025" THICK. ALL EXHAUST FAN OPENINGS TO BE FRAMED WITH 1.5" ANGLE IRON, AT LEAS .025" THICK ALL FOUR SIDES. THE HVAC CONTRACTOR IS ALSO RESPONSIBLE FOR ALL STRUCTURAL STEEL AND LABOR TO INSTALL IT. THE HVAC CONTRACTOR IS ALSO RESPONSIBLE FOR ALL PERMITS, MECHANICAL, STRUCTURAL PERTAINING TO STRUCTURAL STEEL, AND ENGINEERING FEES LISTED ABOVE. THE HVAC CONTRACTOR WILL ALSO BE RESPONSIBLE FOR HAVE IN THE ROOF PENETRATIONS FLASHED BY THE LANDLORDS ROOFER. K. CONDENSATE PIPING 1. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95 -5 TIN- ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER TRADES.SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. 2. EXTERIOR CONDENSATE PIPING SHALL BE SCHEDULE 40 U.V. RESISTANT PVC PIPING. PVC JOINTS SHALL BE SLIP FIT. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. 3. INSULATE ALL INTERIOR CONDENSATE PIPING WITH 1 " THICK (K =0.23 @ 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. 4. INSTALL ALL NECESSARY PIPE HANGERS, AND SADDLES TO PROPERLY SUPPORT ALL CONDENSATE PIPING. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. L. REFRIGERANT PIPING A. THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR FAN UNITS. REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (ASTMB88). TUBING SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. B. ALL FITTING AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER- PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS-5 ALLOY. C. ALL ELBOWS SHALL BE LONG RADIUS TYPE. 3. INSTALLATION A. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND /OR DOUBLE SUCTION RISERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. B. BRAZE ALL JOINTS WITH SILFOS -5 STARTING AT THE INDOOR UNIT AND WORKING TOWARD THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROGEN BLEED SHALL BE USED DURING ALL BRAZING AND ANY TIME THE SYSTEM IS OPEN. ALL OPEN LINES SHALL BE CAPPED AND SEALED BEFORE LEAVING THE SITE DURING CONSTRUCTION. PRESSURE TEST FOR LEAKS WITH AN INERT GAS UP TO 245 PSIG. REDO LEAKING JOINTS AND RETEST UNIT SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 MICRONS OF MERCURY. CHARGE SYSTEM WITH 25 PSI OF R -22 AND AN INERT GAS TO 245 PSI AND RETEST SYSTEM WITH HALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST BE COMPLETELY RESEALED UNTIL NO LEAKS EXIST. TURN ON CRANK CASE HEATERS 24 HRS PRIOR TO STARTING COMPRESSOR TO BE SURE ALL REFRIGERANT LIQUID IS OUT OF THE COMPRESSOR. C. UPON COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION IS APPLIED, THE PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. D. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE LINES ONLY WITH RUBATEX OR ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY STANDARDS. DO NOT INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS LINES IF APPLICABLE. 4. INSPECTION A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL CARRIER FIELD REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL CARRIER INSPECTOR FOR FIELD INSPECTION OF WORK PERFORMED AT G.C.'S EXPENSE. ALL ITEMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY CARRIER FIELD REPRESENTATIVE MUST BE CORRECTED AT NO ADDITIONAL CHARGES TO G.C. OR BIG LOTS M. TEMPERATURE SYSTEM 1. ALL EXISTING AND NEW EQUIPMENT TO HAVE NEW IN DUCT SMOKE DETECTORS AND KEYED RESETS INSTALLED. SEE THE DETAIL FOR LOCATION AND WIRING DIAGRAM. THE SMOKE DETECTORS ARE TO BE INSTALLED AS EARLY IN THE PROJECT AS POSSIBLE TO ALLOW THE FIRE ALARM COMPANY TO HOOK UP THE DETECTOR TO THE FIRE PANEL AT THEIR CONVENIENCE. THE SMOKE DETECTORS SHALL BE A TRANE SYSTEM SENSOR TYPE AND THE TEST STATIONS ARE FIREX MODEL 3PB53, AVAILABLE THROUGH GRANGER. THERE WILL BE SUBSTITUTIONS OF THESE PARTS ALLOWED. THE HVAC CONTRACTOR WILL BE RESPONSIBLE FOR WIRING THESE DETECTORS FOR POWER, UNIT SHUTDOWN, AND THE KEY RESETS. IF YOUR LOCAL CODE REQUIRES THAT ALL OF THE UNITS SHUT DOWN ON CALL FROM ONE OF THE SMOKE DETECTORS, THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PARTS AND LABOR TO MAKE THIS POSSIBLE. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL ELECTRICAL CONDUIT, BOXES, WIRE, AND OTHER PARTS. THE MANUFACTURERS INSTRUCTIONS SHALL BE FOLLOWED WITHOUT ANY OMISSIONS. 2. THERMOSTATS INSTALLED BY THE MECHANICAL CONTRACTOR SHALL BE TEMPORARY TYPE, NON- PROGRAMMABLE CONNECTED TO ALL THE ROOF TOP UNITS VIA 18 -10 TSTAT WIRE. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR THE LOW VOLTAGE WIRING FROM ALL TEMPORARY TSTAT LOCATIONS IN THE STORE TO ALL RTU LOCATIONS ON THE ROOF. TSTAT MOUNTING SHALL BE 60" AFF. IF THE STORE HAS AN EMS SYSTEM DIFFERENT FROM BIG LOTS STANDARD SITE CONTROLS SYSTEM THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING THIS SYSTEM FROM THE HVAC EQUIPMENT ONLY. IF THE HVAC EQUIPMENT HAS LINE VOLTAGE CONTROLS, THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR CONVERTING TO A 24 VOLT CONTROL SYSTEM INCLUDING ALL WIRING, RELAYS, BOX'S, AND CONDUIT. 3. TEMPORARY TSTAT SHALL BE REPLACED, BY THE EMS CONTRACTOR, WITH PERMANENT DIGITAL ZONE CONTROLS (DZC). DZC SHALL BE MOUNTED AT 60" A.F.F. EMS CONTRACTOR SHALL PLACE THE TEMP. STATS IN THE EMS CABIN AIR BALANCE QTY. UNIT SUPPLY RETURN OUTSIDE EXHAUST RESULT SERVING 1 (E)RTU -1 3000 2400 600 - +600 WAREHOUSE /RR 1. (E)RTU -2 5000 4000 1000 - +1000 WAREHOUSE 1 (E)RTU -3 5000 3750 1250 - +1250 SALES 1 (E)RTU -4 5000 3750 1250 - +1250 SALES 1 (E)RTU -5 6000 4800 1200 - +1200 SALES /OFFICE 1. (E)RTU -6. 6000 4800 1200 A +1200 SALES 1 (E)RTU -7 1600 1280 320 - +320 SAALE 250 A DOUBLE DEFLECTION CD -1 AF34X 34 "x34" ^320 ESS 1 (E)EF -1 - - - -600 -600 RESTROOMS 1 40 "x40" 4 -16" o 12.5 o 110 A - C 6 THRU 7.5 TON CD -3 AF46X 46 "x46" 4 -18" 0 460 o 42.7 50 A - C 8.5 THRU 10 TON CD -4 AF52X 52 "x52" 4 -20" o 2100 0 (E)RTU -6 A - C 12.5 THRU 15 TON CD -5 AF58X 58 "x58" 6 -18" o TOTAL - - 6820 -600 +6220 - 4 O. TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF HVAC WORK SHALL BE PERFORMED BY AN AABC, NEBB, NBI, OR NCI CERTIFIED CONTRACTOR. THE HVAC CONTRACTOR SHALL INCLUDE THE COST IN BID FOR TESTING AND BALANCING WORK. 2. TESTING, ADJUSTING, AND BALANCING REPORT MUST BE COMPLETE AND TURNED OVER TO THE BIG LOTS HVAC REPRESENTATIVE 1 WEEK PRIOR TO MERCHANDISING DATE. THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH G.C. TO ALLOW ADEQUATE TIME FOR THE AIR BALANCING WORK TO BE COMPLETED. 3. THE HVAC CONTRACTOR SHALL COMPLETE THE AIR BALANCE REVIEW START -UP VERIFICATION CHECKLIST BELOW AND FAX A COPY AS NOTED TO THE AIR BALANCER. A COPY SHALL ALSO BE PROVIDED TO THE BIG LOTS HVAC REPRESENTATIVE AT THIS TIME. 4. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE. HVAC CONTRACTOR SHALL INSTALL A NEW SET OF FILTERS AFTER PROJECT IS COMPLETE. 5. THE HVAC CONTRACTOR MAY ACT AS THE AIR BALANCING CONTRACTOR PROVIDED THEY HOLD ONE OF THE LISTED AIR BALANCING CERTIFICATIONS. IN THIS CASE, THE HVAC CONTRACTOR MAY BE SUBJECT TO HAVE THIER BALANCING REPORT REVIEWED BY AN INDEPENDANT AGENCY. IN THE EVENT OF ANY DISCREPANCIES, THE HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR ANY INCURRED CHARGES DUE TO CORRECTIONS. END OF SECTION 1 1. REFER TO THE DRAWINGS FOR SCOPE OF WORK. 5500 AIR DISTRIBUTION DEVICE SCHEDULE NOTES: 1 SYMBOL KEY - FIRST LETTER: M= MULTI- DIRECTIONAL 5 DAMPERS SHALL BE OPERABLE FROM FACE. S= SUPPLY, R= RETURN, C= CONCENTRIC, M =MULTI DIRECTION "A" OPPOSED BLADE #AG -35. SECOND LETTER: D= DIFFUSER, R= REGISTER, G= GRILLE 'B' RADIAL OPPOSED BLADE #D -75. 2 CATALOG NUMBERS S & R REFER TO TITUS AIR DEVICES. "C" RUSKIN CFD OR CFDR FIRE DAMPER W /VOLUME CONTROL. CATALOG NUMBERS FOR CONCENTRICS DIFFUSERS AND 'D" YOUNG'S REGULATOR. DPR MODEL # 5020-CC MULTI - DIRECTIONAL DIFFUSERS REFER TO EP CUSTOM 6. BORDER STYLE - PRODUCTS, INC. "A" SURFACE MOUNTED 3 CONTACT EP CUSTOM PRODUCTS, INC. AT 704 -483 -8745 OR WWW.EPCUSTOMPRODIJCTS.COM FOR ORDERING OPTIONS. VERIFY LOCATION OF SMOKE DETECTORS, TYPE OF CONNECTION, AND ADAPTOR PANS. "B" LAY -IN, PROVIDE WITH TITUS MODEL #XY -13363 FRAME FOR DRYWALL CEILING MOUNTING, "C" LAY -IN FRAME FOR T -BAR CEILING. 7 MANUFACTURERS - 4 FINISH- OTHER MANUFACTURERS ACCEPTABLE EXCEPT FOR "A" STANDARD WHITE FINISH., CONCENTRIC AND MULTI- DIRECTIONAL DIFFUSERS. "6" UNPAINTED. SYMBOL CATALOG NUMBER SIZE MOUNTING MATERIAL FINISH DPR. BORDER STYLE REMARKS MOD. NECK CLG. OTHER STEEL ALUM. SD -1 TMS 12"x12" 24 "x24' SEE M -1 0 BIG LOTS o 6 A - C OR B SURFACE MOUNT FOR CASH /COUNT SW -1 300RS 14 "x8" 12 "x6" 49. o o 1 A *VENTILATION BASED ON EXHAUST RATE BIG LOTS TOTAL OA REQD. = 5459 BIG LOTS TOTAL OA PROVIDED = 6820 A DOUBLE DEFLECTION SW -2 300RS 18 "x8" 16 "x6" 200 o 0 110 A 67 A DOUBLE DEFLECTION SW -3 300R5 20 "x12" 18 "x10" - o 0 33.4 40 A 250 A DOUBLE DEFLECTION CD -1 AF34X 34 "x34" 4 -14" o 1195 o (E)RTU -4 A 1250 C 3 THRU 5 TON CD -2 AF4OX 40 "x40" 4 -16" o 12.5 o 110 A - C 6 THRU 7.5 TON CD -3 AF46X 46 "x46" 4 -18" 0 460 o 42.7 50 A - C 8.5 THRU 10 TON CD -4 AF52X 52 "x52" 4 -20" o 2100 0 (E)RTU -6 A - C 12.5 THRU 15 TON CD -5 AF58X 58 "x58" 6 -18" o 15.0 • 125.1 A 67 C 15 THRU 20 TON CD -6 AF64X 64"x64" 6 -20" o 460 30 o 12.8 A - C 20 THRU 25 TON RG -1 50F 24"x24" SEE M -1 o 610 o A - A 2'X2' PAN, EGGCRATE ACCEPTABLE R _- 51 1 ".12" M -1 0 0 A - FACE 11• T G -1 50R -SS 12 "x12 24"x24" SEE M -1 0 - o A C SURFACE MOUNT FOR EMPLOYEE R'4 . MD -1 2 -'•Y- - - 0 o - A - - 2 -� LT1- IONAL I DRUM DIFFUSER MD -2 3 -WAY- - - . o o . A ROOFTOP AIR CONDITIONING UNIT SCHEDULE NOTES: 3 WAY MULTI - DIRECTIONAL DRUM DIFFUSER MD -3 4 -WAY - - o o A - 4 WAY MULTI - DIRECTIONAL DRUM DIFFUSER EXHAUST FAN SCHEDULE MARK LOCATION MANUFACT. MO. # EX. AIR (CFM ST. PRESS. " • W.G. POWER VOLTS/ p WEIGHT :5) NOTES f EF -1 () RESTROOM 20604 BA ANCE TO 600 7.5 4990 120/1 BIG LOTS OFFICE 5 - 0.06 3000 230 65 BIG LOTS RESTROOMS* 6 397 EXHAUST FAN SCHEDULE NOTES: ROOM SERVED. WHITE GRILLE. FLEX DUCT CONNECTORS TO ISOLATE UNIT VIBRATIONS. HOODED WALL CAP. VENT FOR WALL TERMINATION. RISE THERMOSTAT. 1. FAN TO BE TIED INTO LIGHT SWITCH FOR 2. PROVIDE WITH BACKDRAFT DAMPER AT UNIT, 3. PROVIDE WITH ISOLATION HANGERS. INSTALL 4. PROVIDE GREENHECK MODEL WC-10 X 3 5. PROVIDE GREENHECK MODEL BV168 BRICK 6. FAN TO RUN UPON MAKE OF THERMOSTAT. 7. PROVIDE WITH LINE VOLTAGE CLOSE ON IMC VENTILATION SCHEDULE 2009MECHA I ALCODE TABLE SPACE AREA P /1000 FIXTURES SF #P OR CFM /SF CFM/P OA CFM SUPPLY REQ'D OA BIG. LOTS SALES 15 20604 0.12 7.5 4990 4798 BIG LOTS OFFICE 5 - 0.06 3000 230 65 BIG LOTS RESTROOMS* 6 397 - -70 -600 EX -210 BIG LOTS WAREHOUSE / CORRIDOR 67 49. 1051 1 596 *VENTILATION BASED ON EXHAUST RATE BIG LOTS TOTAL OA REQD. = 5459 BIG LOTS TOTAL OA PROVIDED = 6820 MECHANICAL EQUIPMENT SCHEDULE MARK CFM O.A. CFM S.P. VOLTS/ PHASE FAN BHP MCA/ MOCP EER/ SEER HEATING COOLING MANUFACTURER/ MODEL WEIGHT (LBS) REMARKS INPUT MBH OUTPUT MBH NOM. TONS TOTAL MBH SENS. MBH ENT. D.B. ENT. W.B. (E)RTU-1 3000 600 460 30 2 HP 21.7 25 9.0 - 150 120 7.5 86.0 64.0 80 67 YORK DH090N15P4AAA1A 1051 (E)RTU -2 5000 1000 - 460 30 5 HP 33.4 40 9.0 - 250 200 12.5 140 110 80 67 YORK DH150N20P4AAA1A 1195 (E)RTU -3 5000 1250 - 460 30 5 HP 33.4 40 9.0 250 200 12.5 140 110 80 67 YORK DH150N20P4AAA1A 1195 (E)RTU -4 5000 1250 - 460 30 5 HP 33.4 40 9.0 - 250 200 12.5 140 110 80 67 YORK DH150N20P4AAA1A 1195 (E)RTU -5 6000 1200 - 460 5 HP 42.7 50 10.0 300 240 15.0 175.5 125.1 80 67 YORK D1HG 80N24046ECA 2100 - (E)RTU -6 6000 1200 - 460 30 5 HP 42.7 50 10.0 300 240 15.0 175.5 125.1 80 67 YORK D1 HG 80N24046ECA 2100 - (E)RTU -7 1600 320 460 30 1.5 HP 12.8 125 99 4 46.5 36.0 80 67 YORK D1HG048N09946BOB 610 0 OP - - _ . . _ _ - . . . . ROOFTOP AIR CONDITIONING UNIT SCHEDULE NOTES: AMBIENT OUTDOOR TEMPERATURE OF 95 DEG. F. PRIOR TO TEST AND BALANCE WORK. E.,..... , AND ACCESSORIES 2:eyi i. COOLING CAPACITIES SHOWN ARE BASED ON AN 2. CONTRACTOR SHALL INSTALL ALL NEW FILTERS 3. FACTORY ECONOMIZER 4. FACTORY NON -FUSED DISCONNECT SWITCH 5. FACTORY GFCI OUTLET - NON POWERED 6. FACTORY ROOF CURB 7. WEIGHTS INCLUDE ROOF CURB, ECONOMIZER, UNIT, RO 8. 9. AUG 1 4 2012 PEAS PERMIT AND APPROVAL 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW ######### PERMIT ####### ### BID ### # ###### CONSTRUCTION ####### # ## WD PROJECT NUMBER ## •'C $ VAN OF WAS T EXHAUST FAN ROOF CURB 10 "1Y TO CEILING 14114 DUCT UP TO THE CURB REST ROOM EXHAUST DETAIL N.T.S. ADAPTOR PANS ROOF CURB ROOFING SUPPLY DUCT FULL SIZE DRUM DIFFUSER ROOFING ROOF TRUSS ROOF TRUSS ACCESS DOOR SMOKE DETECTOR RETURN DUCT FULL SIZE NOTE: VERIFY WITH LOCAL AUTHORITIES HAVING JURISDICTION ON LOCATION OF SMOKE DETECTORS. CONTRACTOR TO VERIFY RETURN, SUPPLY, OR BOTH. DURM DIFFUSER DETAIL N.T.S. SCN aD PVC PIPING PRESSURE TREATED WOOD BLOW. ROOFNG NALV, Z 0 (7)_ W cc W 1- �C 0 METAL STRAPPNG GIV.VAMZED SCREWS MASTIC SEMER OR �' CONSTRUCION ADHESIVE : MAXIMUM SPACING SHALL BE J'.P 2: PIPING SHALL BE SLOPED TO APPROVED OUTLET CU FACTORY W 14" HIGH FACTORY ROOF CURB THROUGH MR NAILER AND CURB IDE 3 PER LONG SIDE AND SIDE. BASE RAIL ON LNR METAL DECKING ( TYPICAL ) BOLT SETS: 1/2, (2) PER SIDE. THRU BASE OF CURB AND FRAME (1700 LBS, TENSION 2200 LBS SHEAR CAPACITY.) STRUCTURAL SUPPORT FRAME FOR UNIT 6 DECKING AT FULL PERIMETER OF FACTORY CURB 3.7(3- X 1,1. ANGLE IRON AT ENDS OLT CURB TO BAR JOISTS AM E IRON FOR NEW LOCATIONS. Y EXISTING STEEL FOR EXISING ATIONS TO BE REUSED. 5 CC IC W < 0- Z cc W V/�I- co CC Z W W co a. U = Q (/) Q O Q J CC c SQUARE FOOTAGE (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 DATE DRAW cV DRAWN BY w J U CD II N ccE) M cc O p_ N Z W M O 0 00 0 ``^^ 1 VJ WOQQao CC O =N O ix 0 -`^ r VJ < u T 0 W = W J CC 0_ J O O C3 o° O co cn co O o 1: MECHANICAL CONTRACTOR SHALL FURNISH ROOF OPENING SIZES AND LOCATIONS FOR STRUCTURAL SUPPORT FRAMING. 2 SYSTEM SHALL BE CAPABLE OF W RI£TANDING WIND FORCE IN ACCORDANCE WITH THE 200E FLORIDA BUILDNG CODES. ITIE•DOWN SYSTEM HAS BEEN DESIGNED FOR. 146 MPH WIM) FORCE MNMUMI. 3 FACTORY HURRICANE CLIPS. ALSO ACCEPTABLE. INSTALL AS PER MANUFACTURES INSTRUCTIONS. RTU CURB/TIE DOWN DETAIL N.T.S. SZpq REq ��A Np MECHANICAL NOTE° SHEET: M -2 KEYED NOTES EXISTING ROOF TOP UNIT TO BE REUSED. CONTRACTOR TO INSPECT EXISTING RTU. SEE GENERAL NOTES FOR RTU WORK. REPAIR AND REPLACE AS REQUIRED. REBALANCE TO QUANTITIES SHOWN ON SHEET M -2. VERIFY EXACT LOCATION. CONTRACTOR TO INSPECT EXISTING EXHAUST FANS. SEE GENERAL NOTES THIS SHEET FOR EXHAUST FAN WORK. REPAIR AND REPLACE AS REQUIRED. REBALANCE TO QUANTITIES SHOWN ON SHEET M -2. VERIFY EXACT LOCATIONS. EXISTING DUCT WORK TO REMAIN. CONTRACTOR TO REMOVE. CLEAN, REPAINT, AND REINSTALL EXISTING DIFFUSERS AND GRILLES, DESIGNATED (E). CONTRACTOR TO REMOVE EXISTING DUCT WORK AND ASSOCIATED DIFFUSERS AND GRILLES, DESIGNATED (D). DISPOSE OF REMOVED MATERIALS PROPERLY. CAP ALL OPENINGS AIR TIGHT WHERE DUCT IS REMOVED. CONTRACTOR TO INSPECT, CLEAN AND VERIFY FUNCTIONALITY EXISTING UNIT HEATER. REPAIR AND REPLACE AS REQUIRED. VERIFY EXACT LOCATION. GENERAL NOTES ROOF TOP UNIT REUSE REQUIREMENTS INITIAL INSPECTION AND CORRECTIVE ACTION. O OBTAIN, IF POSSIBLE, THE MAINTENANCE RECORDS OF THE UNIT. PROVIDE WITH FINAL INSPECTION REPORT TO CLIENT. HIGHLIGHT TROUBLE COMPONENTS AND ADVISE WHICH ONES ARE OUT OF WARRANTY. O VISUALLY INSPECT AND CORRECT UNIT FOR: *DIRTY FILTERS - REPLACE WITH NEW PLEATED FABRIC TYPE AND PROVIDE AND AN ADDITIONAL SET FOR INSTALLATION PRIOR TO TURN OVER. *DIRT AND DEBRIS BUILT UP IN CONDENSER COIL - CHEMICALLY CLEAN COIL , BRUSH OUT FINS. *DIRT AND DEBRIS BUILT UP ON FAN BLADES. - CHEMICALLY CLEAN *DIRT AND DEBRIS BUILT UP IN EVAPORATOR COIL- CHEMICALLY CLEAN COIL. *DIRT AND DEBRIS BUILT UP ON HEAT EXCHANGER - GAS HEAT - CHEMICALLY CLEAN AND CHECK FOR LEAKS AND CORROSION. *DIRT AND DEBRIS BUILT UP IN OUTSIDE AIR DAMPER AND ACTUATOR. - CLEAN DAMPER AND ACTUATOR, LUBRICATE AND MAKE SURE DAMPER IS OPERATIONAL. *IF ECONOMIZER, ENSURE THAT OUTSIDE STAT AND /OR DIFFERENTIAL TEMPERATURE CONTROLLER IS FULLY OPERATIONAL. *CORROSION ON OUTSIDE CABINET OF UNIT. - CLEAN, PAINT AND PATCH AS REQUIRED. *INSPECT ALL ACCESS PANELS - REPLACE DEFECTIVE GASKETS AND MISSING SCREWS AND LATCHES. *ENSURE THAT UNIT AND ROOF CURB PROVIDED AIR TIGHT SEAL - CORRECT ANY AIR LEAKAGE AT UNIT. 2. MECHANICAL INSPECTION AND CORRECTIVE ACTION REQUIREMENTS. O SUPPLY FAN MOTOR - *CHECK THAT MOTOR IS WIRED CORRECTLY. *CHECK THAT FAN IS ALIGNED PROPERLY, MAKE SURE THAT IT DOES NOT HAVE EXCESSIVE VIBRATION OR CREATING EXCESSIVE NOISE WHILE OPERATING. *REPLACE BELT IF BELT DRIVEN. - USE V NOTCHED BELT TYPE IF POSSIBLE. *SET NEW BELT AT FACTORY RECOMMENDED TENSION. *LUBRICATE AS REQUIRED OR AS PER LUBRICATION LABEL ON UNIT. *CHECK AIR FLOW FROM FAN AT SUPPLY AIR DUCT THAT IT IS WITHIN 350 -400 CFM PER TON RANGE REQUIRED FOR TONNAGE OF UNIT O COMPRESSOR - *PERFORM AN ELECTRICAL AND AN OIL TEST ON THE REFRIGERANT FOR MOISTURE AND /OR ACID IS PRESENT. - INSTALL A NEW FILTER/DRYER. *CHECK TEMPERATURE OF CASING. IF CASING IS INDICATING EXCESSIVE TEMPERATURES REPLACEMENT MIGHT BE NECESSARY. REPORT FINDINGS WITH RECOMMENDATIONS TO OWNER. *PRESSURE CHECK SYSTEM TO SPECIFICATIONS FROM MANUFACTURER. *CHECK FOR AND REPAIR ANY LEAKS IN SYSTEM. RECHARGE IF REQUIRED OR IF OVERCHARGED SUBMIT RECOMMENDATIONS TO OWNER FOR RECTIFYING. O CONDENSER FAN AND MOTOR - *CHECK THAT FAN IS ALIGNED PROPERLY, AND OPERATING PROPERLY. *REPLACE IF REQUIRED. EXHAUST FAN INSPECTION INITIAL INSPECTION AND CORRECTIVE ACTION. O OBTAIN IF POSSIBLE THE MAINTENANCE RECORDS OF THE UNIT. PROVIDE WITH FINAL INSPECTION REPORT TO CLIENT. HIGHLIGHT TROUBLE COMPONENTS AND ADVISE WHICH ONES ARE OUT OF WARRANTY. O VISUALLY INSPECT AND CORRECT UNIT FOR: *DIRT AND DEBRIS BUILT UP ON FAN BLADES. - CHEMICALLY CLEAN *DIRT AND DEBRIS BUILT UP IN BACKDRAFT DAMPER. - CLEAN DAMPER. LUBRICATE AND MAKE SURE DAMPER IS OPERATIONAL. *ENSURE THAT UNIT AND ROOF CURB PROVIDED AIR TIGHT SEAL - CORRECT ANY AIR LEAKAGE AT UNIT. 2. MECHANICAL INSPECTION AND CORRECTIVE ACTION REQUIREMENTS. O EXHAUST FAN MOTOR - *CHECK THAT MOTOR IS WIRED CORRECTLY. *CHECK THAT FAN IS ALIGNED PROPERLY, MAKE SURE THAT IT DOES NOT HAVE EXCESSIVE VIBRATION OR CREATING EXCESSIVE NOISE WHILE OPERATING. *REPLACE BELT IF BELT DRIVEN. - USE V NOTCHED BELT TYPE IF POSSIBLE. *SET NEW BELT AT FACTORY RECOMMENDED TENSION. *LUBRICATE AS REQUIRED OR AS PER LUBRICATION LABEL ON UNIT. *CHECK AIR FLOW FROM FAN AT EXHAUST AIR DUCT. REBALANCE CFM ACCORDING TO PLAN. (E)t6" OLL 1250 (TYP) I�1 11 II Iw 11 11 (E)SD 1250 (TYP) (E)SD 1250 (E) RTU #2 II JL -Ir-- - --1I— 1i II (°' II' II II II _ J "1 (D)SD (TYP) ( (D)EF (D)SD (D)EF tet (D)RG u I(I 1211aD)SD 11 I*IL (D)SD (D)EG I 1 (D)16" II —t �(D)RG�r II (E) RTU #1 II 11 I! (D)EFt 5 ) 11 (TYP) I (D)RG I (D) If II (D)S) IIJ (TYP) (E)SD 1250 11_( E)16" r(E)16" [(E)SD 1250 (D)SD D)6 I I 01E) RTU #7 (E)20" (E)SD 1250 Fr(E)16" (E)20" lr( E)1 6" E SD 1250 (TYP) 0 (E) RTU #4 1 (E)RG (E)RG 0 (E) RTU #3 ✓ 1 (E)RG 0 (D)SD (E)16" (D)SD (E)20" 1250 1250 (TYP) I/- (E)16" I E)16" (E)SD 1250 1250 (E)SD 1250 •(E)16" E)16" (E)SD 1250 (14' (D)SD — (D)14„ II D)6„ 11 1EZ2 rSJ )- JII r;;-- Ji �(D)D® IIII II II � I II LI I�YP) _ _ _ 1L — _ —(D D I� — UI L� 0 0 0 1400 V E)S (TYP) (E)SD 1350 (E)16" r(E)16" t•1 (E)SD 1350 I(E)16" 1 T 1(E)1 6" Vkl (E)SD 1400 id I .(E)SD .- 1000 (E)SD 1000 1 1 l jaw r .1_,H (E)14" E SD 1000 (TYP) (D)16" 0 (D)SD -(TYP) 0 (D)20" SEPARATE PERMIT AND APPROVAL REQUIRED ED)SC (D)SD (D)SD O fff (TYP) wd 7007 DISCOVERY BLVD DUBLIN, OH 43017 814.634.7000 T WDPARTNERS. COM ISSUE DATE CLIENT REVIEW #### ####A PERMIT ### # # ###A BID ########A CONSTRUCTION #### ####A WD PROJECT NUMBER ######## CITYS, AUG 1.4 2012 PERMIT CENTER MECHANICAL DEMOLITION PLAN LU i- < 0 Q CC W Z W Lu co ac z•° W W 00 Q cn H D < 0 < H J rrs CC c° CE a_ T- SQUARE FOOTAGE O CO O N W cri J (INCLUDES FURNITURE DEPT.) TOTAL: 27,497 0 W 0 N DRAWN BY C .0 W J U 0) o /own _ 1r nv N (.3 Z W M 0 WzQO IM 0 OzocO w 171- J m mU)coO O O co sob (9 N (0 LLI O IZ SHEET: M- PROVIDE SPECIFIED FIXTURE OR APPROVED EQUAL DIVISION 1- MECHANICAL 1. PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY TO EXECUTE THE PLUMBING WORK INDICATED ON THE DRAWINGS, AND AS REQUIRED BY LOCAL CODES AND ORDINANCES. 2. PAY ALL FEES AND ARRANGE FOR EXECUTION OF ALL TAPS, METERS WITH REQUIRED ENCLOSURES (IF ANY), ETC. INHERENT TO THE INSTALLATION OF NEW PLUMBING SERVICE. 3. PLUMBING WORK FOR THIS CONTRACT SHALL INCLUDE ALL PIPING FOR DOMESTIC HOT AND COLD WATER LINES INES AND SANITARY LINES, HOOK -UP OF ALL FIXTURES SCHEDULED ON THE DRAWINGS, AND INSULATION OF DESIGNATED PIPING RUNS. WORK SHALL ALSO INCLUDE ALL GAS PIPING AND EQUIPMENT CONNECTIONS WHERE REQUIRED. 4. ALL ITEMS SUCH AS FITTINGS, ETC. NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY TO COMPLETE THE PLUMBING SYSTEM SHALL BE INCLUDED. 5. SOIL, WASTE, AND VENT PIPING TO BE OF MATERIAL APPROVED BY LOCAL CODES. PVC, DWV PIPING AND FITTINGS TO BE SCHEDULE 40 AS A MINIMUM. 6. PROVIDE CLEANOUTS FOR SOIL AND WASTE LINES AS SHOWN ON DRAWINGS, AND OF TYPE APPROVED BY LOCAL CODES. 7. ALL WATER SUPPLY PIPING BELOW GROUND SHALL BE TYPE K SOFT COPPER TUBING, (AVOID FITTINGS BELOW SLAB WHENEVER POSSIBLE). ALL WATER SUPPLY PIPING ABOVE GROUND SHALL BE TYPE L HARD COPPER TUBING. 8. PROVIDE FOR DRAINING WATER SYSTEM, AND CAP ALL STUBS UNTIL FINISH WORK IS INSTALLED. INSTALL DRAIN VALVE AT WATER METER WITH 3/4" HOSE THREAD AND VACUUM BREAKER. 9. PROVIDE STOPS ON WATER SUPPLIES TO EACH FIXTURE. 10. GAS PIPING FOR HEATING SYSTEMS WITH GAS -FIRED EQUIPMENT SHALL BE INCLUDED IN THIS CONTRACT. GAS PIPING SHALL BE STANDARD WEIGHT, BLACK STEEL PIPE, SCHEDULE 40L. PIPING EXPOSED TO ATMOSPHERE OR RUN BELOW GRADE SHALL HAVE POLYETHYLENE PLASTIC COATING AND VENTED TO OUTDOORS. ALL GAS PIPING, FITTINGS AND INSTALLATION SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF UTILITY COMPANY AND ALL GOVERNING BODIES. 11. INSULATE ALL COLD AND HOT WATER PIPING WITH ARMSTRONG COMPANY ARMAFLEX "11" PIPE INSULATION. SEAL JOINTS WITH ARMSTRONG 520 ADHESIVE. IMPORTANT - HOLD ALL COLD AND HOT WATER PIPING TO WARM SIDE OF INSULATION TO PROHIBIT FREEZING. INSULATION SHALL MEET FLAME SPREAD AND SMOKE DEVELOPED RATINGS REQUIRED BY LOCAL CODES. 12. PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED WHERE SHOWN ON THE DRAWINGS. ALL FIXTURE FITTINGS AND EXPOSED FIXTURE PIPING SHALL BE BRASS CHROMIUM PLATED. ALL TRAPS SHALL BE CAST BRASS. ALL FIXTURES SHALL BE BONE, FIXTURES SHALL BE AS MANUFACTURED BY AMERICAN STANDARD, KOHLER OR CRANE AND EQUAL IN ALL RESPECTS TO FIXTURES SPECIFIED. CLOSET SEATS SHALL BE BEMIS. WATER CLOSET (WC -1) NO. 2234.001 AMERICAN STANDARD: ELONGATED' WHITE" WATER -SAVER "MADERA" VITREOUS CHINA TOILET NO. 169 MCQUIRE FLEXIBLE SUPPLY STOP NO. 95 ELONGATED "OLSONITE" #95 OPEN FRONT SEAT. NOT SELF - SUSTAINING HINGE NO. 111 -1.28 SLOAN FLUSH VALVE ...( CSUW PPLY ro / 1�� ? cW 1 SUPPLY N. BALL VALVE INSTALL IN WALL TRAP PRIMER DISTRIBUTION LINES TO FLOOR DRAINS AS REQUIRED 12 "x 12" ACCESS PANEL ACCESS PANEL FRAME 1' -0" AFF FOR EVERY 20' -0" OF PRIMER LINE TRAP PRIMER DETAIL SCALE: N.T.S. WATER CLOSET (WC -2) NO. 3043.001 AMERICAN STANDARD: ELONGATED "WHITE" WATER -SAVER "MADERA" VITREOUS CHINA TOILET 17" RIM HEIGHT MCGUIRE FLEXIBLE SUPPLY STOP ELONGATED "OLSONITE" #95 OPEN FRONT SEAT. NOT SELF - SUSTAINING HINGE SLAON FLUSH VALVE NO. 169 NO. 95 NO. 111 -1.28 LAVATORY (LAV -1) NO. 0356.421 NO. 8872 NO. 701 -HDF NO. 167 AMERICAN STANDARD, WALL MOUNT, CONCEALED ARMS MCGUIRE ADJUSTABLE CAST BRASS "P" TRAP WITH TUBING DRAIN TO WALL 1 1/4 "x 1 1/2 INLET AND OUTLET, CLEANOUT PLUG ESCUTCHEON DELTA FAUCET WITH GRID STRAINER MCGUIRE FLEXIBLE TUBE RISER, WHEEL HANDLE STOP, ESCUTCHEON, PROVIDE WITH WALL HANGERS URINAL (UR -1) NO. WEUS- 1002.1401 -0.25 SLOAN: "OPTIMA PLUS" WHITE VITREOUS CHINA, WASHDOWN FLUSH ACTION. WALL HUNG, PROVIDE STRAINER FIXTURES AND EQUIPMENT FIXTURES AND EQUIPMENT BY OTHERS. ROUGH -IN AND FINAL CONNECTIONS OF REQUIRED WASTE, VENT, AND WATER SUPPLY PIPING BY PLUMBING CONTRACTOR. ALL SUPPLY PIPING SHALL BE VALVED. 13. WATER METER IS A POSITIVE DISPLACEMENT METER OF THE NUTATING DISC TYPE OR AS REQUIRED BY LOCAL UTILITY COMPANY. 14. WATER HEATERS SHALL BE MANUFACTURED BY A.O. SMITH, RUUD. OR STATE. INSTALL SHUT OFF VALVE IN COLD AND HOT WATER LINES AT SUPPLY OF HEATER. PROVIDE DIELECTRIC COUPLINGS WHERE FERROUS AND NON- FERROUS MATERIALS ARE IN CONTACT. PROVIDE TEMPERATURE- PRESSURE RELIEF VALUE AT HEATER. VALVE SETTING: 210°F AND 125 PSIG. DISCHARGE FULL SIZE THROUGH PIPE TO FLOOR DRAIN. 15. WALL HYDRANTS SHALL BE FREEZELESS AUTOMATIC DRAINING TYPE AS MANUFACTURED BY WOODFORD, MODEL #67 OR EQUAL BY ZURN OR WADE. 16. COORDINATE ALL WORK WITH ELECTRICAL AND HVAC CONTRACTORS. 17. THIS CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE BUILDING BY THE OWNER, THIS CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER. 18. BACKFLOW PREVENTER TO BE INSTALLED WHEN REQUIRED BY LOCAL CODE AND IS TO BE PROVIDED BY AND INSTALLED BY THE PLUMBING CONTRACTOR. KEYED NOTES: O CONNECT NEW 4" SANITARY LINE TO EXISTING SANITARY LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING SANITARY LINE. 0 CONNECT NEW 1 -1/2" CW LINE TO EXISTING CW LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING CW LINE. CONNECT NEW 3/4" HW LINE TO EXISTING HW LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING HW LINE. O EXISTING RESTROOMS TO REMAIN. CLEAN ALL FIXTURES AND VERIFY SEALS FOR THE FIXTURES. REPAIR AND REPLACE AS NECESSARY. O CONNECT NEW 2" VENT LINE TO EXISTING VENT LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING VENT LINE. RISER DIAGRAM SCALE.. NTS SEE STACK AND RISER DIAGRAMS FOR PIPE SIZES (E)LAV -1 (E)LAV -t (E)DF -1 n (E)LAV -1 (E)LAV -1 PLUMBING PLAN SCALE: 1/4" = 1' -0" 2,31 I \ \ rI \\ 2/ rL % / FCO STACK DIAGRAM SEPARATE PERMIT AND APPROVAL REQUIRED Tp WASTE PIPING - - - VENT PIPING FD FLOOR DRAIN WC WATER CLOSET LAV LAVATORY VTR VENT THRU ROOF MS SERVICE SINK DF DRINKING FOUNTAIN UR URINAL TP TRAP PRIMER WCO WALL CLEAN OUT FCO FLOOR CLEAN OUT r TUK AUG 14 -2012 PERMIT CENTER PLUMBING PLAN wd 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW # #### ### ## PERMIT # #### ### ## BID ##### ### ## CONSTRUCTION # #### ### ## WD PROJECT NUMBER ### #### Z 0 w cc W 1- Q cc cc wQ z w w co E..z w w � _ <t (0 < 0 < r- -j ©� o CO Y m w 1- O 0 LL w cc 0 z w 0 I D w O w S Q H CO z O N (n w p L11 J J 2 TOTAL: 27,497 N Lf) to DRAWN BY 0 W -J U (1) I I CO CO H CO 111 cN c) 0 00 z 0^' Q ciU)`� J J a J co cc a D z • J U)co00_ PLUMBING FIXTURE SCHEDULE ITEM DESCRIPTION ROUGH -IN PIPING SPECIFICATIONS REMARKS WASTE VENT HOT WATER COLD WATER WSFU CARRIER MODEL COLOR ACCESSORIES WC -1 WATER CLOSET 4" 2" 1" 10 AMERICAN STANDARD 2234.001 WHITE SLOAN FL TER ROYAL ttt -1.28 -1.28 1.28 GPF AMERICAN SLOAN FLUSHOMETER WC 2 WATER CLOSET 4" 2" 1 5IANUAHU 36'43"601 WHITE ROYAL 111 -1.28 O1 1.20 err UR -I URINAL 2" 1 t /2" 3f4" 5 3LOAtd WE1J3- t002.100I -0.25 WHITE .25GPr LAV -1 LAVATORY 1 1/2" 1 1/2' 1/2" 1/2" 2 AMERICAN STANDARD STANDARD. 0356.421 WHITE DELTA 701 -HIDE MS -1 MOP SINK 3" 1 1/2" 1/2" 1/2" 3 FIAT MSB -2424 830 AA 1453 BB " ` DF-1 DRINKING FOUNTAIN t 1/2" I I /2 ttr 8.5 ELK1kY EZ3?L8tC GRAY EZSTL8LC 1@ DUAL IIEIGI IT FCO FLOOR CLEAN OUT ZURN ZN1400 -HD FD FLOOR DRAIN 3" ZURN ZN400C GOO WH- 1 WATER HEATER 3/4" 3/4' A: O. 3M1Th Bt-t -20 TP TRAP PRIMER 1/2" PRECISION PLUMBING PRODUCTS FR -500 O WHA WATER HAMMER ARRESTOR LINE SIZE PRECISION PLUMBI SC WGO WALL CLEAN OUT ZttR))td�t 21441 ET- I EXPANSION TANK 314•" OSSETT PT -12 REMARKS: 0 ADA @ WITH DRAIN PAN UNDER WATER HEATER 0 INSTALLED IN WALL WITH ACCESS PANEL ELMDOR VB V PROVIDE 120V, 3KW SINGLE ELEMENT O T &P RELIEF FULL SIZE 60 PROVIDE MIXING VALVE FOR TEMPERED HOT WATER SET AT 110 DEG F OUTLET PROVIDE SPECIFIED FIXTURE OR APPROVED EQUAL DIVISION 1- MECHANICAL 1. PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY TO EXECUTE THE PLUMBING WORK INDICATED ON THE DRAWINGS, AND AS REQUIRED BY LOCAL CODES AND ORDINANCES. 2. PAY ALL FEES AND ARRANGE FOR EXECUTION OF ALL TAPS, METERS WITH REQUIRED ENCLOSURES (IF ANY), ETC. INHERENT TO THE INSTALLATION OF NEW PLUMBING SERVICE. 3. PLUMBING WORK FOR THIS CONTRACT SHALL INCLUDE ALL PIPING FOR DOMESTIC HOT AND COLD WATER LINES INES AND SANITARY LINES, HOOK -UP OF ALL FIXTURES SCHEDULED ON THE DRAWINGS, AND INSULATION OF DESIGNATED PIPING RUNS. WORK SHALL ALSO INCLUDE ALL GAS PIPING AND EQUIPMENT CONNECTIONS WHERE REQUIRED. 4. ALL ITEMS SUCH AS FITTINGS, ETC. NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY TO COMPLETE THE PLUMBING SYSTEM SHALL BE INCLUDED. 5. SOIL, WASTE, AND VENT PIPING TO BE OF MATERIAL APPROVED BY LOCAL CODES. PVC, DWV PIPING AND FITTINGS TO BE SCHEDULE 40 AS A MINIMUM. 6. PROVIDE CLEANOUTS FOR SOIL AND WASTE LINES AS SHOWN ON DRAWINGS, AND OF TYPE APPROVED BY LOCAL CODES. 7. ALL WATER SUPPLY PIPING BELOW GROUND SHALL BE TYPE K SOFT COPPER TUBING, (AVOID FITTINGS BELOW SLAB WHENEVER POSSIBLE). ALL WATER SUPPLY PIPING ABOVE GROUND SHALL BE TYPE L HARD COPPER TUBING. 8. PROVIDE FOR DRAINING WATER SYSTEM, AND CAP ALL STUBS UNTIL FINISH WORK IS INSTALLED. INSTALL DRAIN VALVE AT WATER METER WITH 3/4" HOSE THREAD AND VACUUM BREAKER. 9. PROVIDE STOPS ON WATER SUPPLIES TO EACH FIXTURE. 10. GAS PIPING FOR HEATING SYSTEMS WITH GAS -FIRED EQUIPMENT SHALL BE INCLUDED IN THIS CONTRACT. GAS PIPING SHALL BE STANDARD WEIGHT, BLACK STEEL PIPE, SCHEDULE 40L. PIPING EXPOSED TO ATMOSPHERE OR RUN BELOW GRADE SHALL HAVE POLYETHYLENE PLASTIC COATING AND VENTED TO OUTDOORS. ALL GAS PIPING, FITTINGS AND INSTALLATION SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF UTILITY COMPANY AND ALL GOVERNING BODIES. 11. INSULATE ALL COLD AND HOT WATER PIPING WITH ARMSTRONG COMPANY ARMAFLEX "11" PIPE INSULATION. SEAL JOINTS WITH ARMSTRONG 520 ADHESIVE. IMPORTANT - HOLD ALL COLD AND HOT WATER PIPING TO WARM SIDE OF INSULATION TO PROHIBIT FREEZING. INSULATION SHALL MEET FLAME SPREAD AND SMOKE DEVELOPED RATINGS REQUIRED BY LOCAL CODES. 12. PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED WHERE SHOWN ON THE DRAWINGS. ALL FIXTURE FITTINGS AND EXPOSED FIXTURE PIPING SHALL BE BRASS CHROMIUM PLATED. ALL TRAPS SHALL BE CAST BRASS. ALL FIXTURES SHALL BE BONE, FIXTURES SHALL BE AS MANUFACTURED BY AMERICAN STANDARD, KOHLER OR CRANE AND EQUAL IN ALL RESPECTS TO FIXTURES SPECIFIED. CLOSET SEATS SHALL BE BEMIS. WATER CLOSET (WC -1) NO. 2234.001 AMERICAN STANDARD: ELONGATED' WHITE" WATER -SAVER "MADERA" VITREOUS CHINA TOILET NO. 169 MCQUIRE FLEXIBLE SUPPLY STOP NO. 95 ELONGATED "OLSONITE" #95 OPEN FRONT SEAT. NOT SELF - SUSTAINING HINGE NO. 111 -1.28 SLOAN FLUSH VALVE ...( CSUW PPLY ro / 1�� ? cW 1 SUPPLY N. BALL VALVE INSTALL IN WALL TRAP PRIMER DISTRIBUTION LINES TO FLOOR DRAINS AS REQUIRED 12 "x 12" ACCESS PANEL ACCESS PANEL FRAME 1' -0" AFF FOR EVERY 20' -0" OF PRIMER LINE TRAP PRIMER DETAIL SCALE: N.T.S. WATER CLOSET (WC -2) NO. 3043.001 AMERICAN STANDARD: ELONGATED "WHITE" WATER -SAVER "MADERA" VITREOUS CHINA TOILET 17" RIM HEIGHT MCGUIRE FLEXIBLE SUPPLY STOP ELONGATED "OLSONITE" #95 OPEN FRONT SEAT. NOT SELF - SUSTAINING HINGE SLAON FLUSH VALVE NO. 169 NO. 95 NO. 111 -1.28 LAVATORY (LAV -1) NO. 0356.421 NO. 8872 NO. 701 -HDF NO. 167 AMERICAN STANDARD, WALL MOUNT, CONCEALED ARMS MCGUIRE ADJUSTABLE CAST BRASS "P" TRAP WITH TUBING DRAIN TO WALL 1 1/4 "x 1 1/2 INLET AND OUTLET, CLEANOUT PLUG ESCUTCHEON DELTA FAUCET WITH GRID STRAINER MCGUIRE FLEXIBLE TUBE RISER, WHEEL HANDLE STOP, ESCUTCHEON, PROVIDE WITH WALL HANGERS URINAL (UR -1) NO. WEUS- 1002.1401 -0.25 SLOAN: "OPTIMA PLUS" WHITE VITREOUS CHINA, WASHDOWN FLUSH ACTION. WALL HUNG, PROVIDE STRAINER FIXTURES AND EQUIPMENT FIXTURES AND EQUIPMENT BY OTHERS. ROUGH -IN AND FINAL CONNECTIONS OF REQUIRED WASTE, VENT, AND WATER SUPPLY PIPING BY PLUMBING CONTRACTOR. ALL SUPPLY PIPING SHALL BE VALVED. 13. WATER METER IS A POSITIVE DISPLACEMENT METER OF THE NUTATING DISC TYPE OR AS REQUIRED BY LOCAL UTILITY COMPANY. 14. WATER HEATERS SHALL BE MANUFACTURED BY A.O. SMITH, RUUD. OR STATE. INSTALL SHUT OFF VALVE IN COLD AND HOT WATER LINES AT SUPPLY OF HEATER. PROVIDE DIELECTRIC COUPLINGS WHERE FERROUS AND NON- FERROUS MATERIALS ARE IN CONTACT. PROVIDE TEMPERATURE- PRESSURE RELIEF VALUE AT HEATER. VALVE SETTING: 210°F AND 125 PSIG. DISCHARGE FULL SIZE THROUGH PIPE TO FLOOR DRAIN. 15. WALL HYDRANTS SHALL BE FREEZELESS AUTOMATIC DRAINING TYPE AS MANUFACTURED BY WOODFORD, MODEL #67 OR EQUAL BY ZURN OR WADE. 16. COORDINATE ALL WORK WITH ELECTRICAL AND HVAC CONTRACTORS. 17. THIS CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE BUILDING BY THE OWNER, THIS CONTRACTOR SHALL REPAIR AND /OR REPLACE ANY DEFECTIVE ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER. 18. BACKFLOW PREVENTER TO BE INSTALLED WHEN REQUIRED BY LOCAL CODE AND IS TO BE PROVIDED BY AND INSTALLED BY THE PLUMBING CONTRACTOR. KEYED NOTES: O CONNECT NEW 4" SANITARY LINE TO EXISTING SANITARY LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING SANITARY LINE. 0 CONNECT NEW 1 -1/2" CW LINE TO EXISTING CW LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING CW LINE. CONNECT NEW 3/4" HW LINE TO EXISTING HW LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING HW LINE. O EXISTING RESTROOMS TO REMAIN. CLEAN ALL FIXTURES AND VERIFY SEALS FOR THE FIXTURES. REPAIR AND REPLACE AS NECESSARY. O CONNECT NEW 2" VENT LINE TO EXISTING VENT LINE. VERIFY EXACT LOCATION AND SIZE OF EXISTING VENT LINE. RISER DIAGRAM SCALE.. NTS SEE STACK AND RISER DIAGRAMS FOR PIPE SIZES (E)LAV -1 (E)LAV -t (E)DF -1 n (E)LAV -1 (E)LAV -1 PLUMBING PLAN SCALE: 1/4" = 1' -0" 2,31 I \ \ rI \\ 2/ rL % / FCO STACK DIAGRAM SEPARATE PERMIT AND APPROVAL REQUIRED Tp WASTE PIPING - - - VENT PIPING FD FLOOR DRAIN WC WATER CLOSET LAV LAVATORY VTR VENT THRU ROOF MS SERVICE SINK DF DRINKING FOUNTAIN UR URINAL TP TRAP PRIMER WCO WALL CLEAN OUT FCO FLOOR CLEAN OUT r TUK AUG 14 -2012 PERMIT CENTER PLUMBING PLAN wd 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM ISSUE DATES CLIENT REVIEW # #### ### ## PERMIT # #### ### ## BID ##### ### ## CONSTRUCTION # #### ### ## WD PROJECT NUMBER ### #### Z 0 w cc W 1- Q cc cc wQ z w w co E..z w w � _ <t (0 < 0 < r- -j ©� o CO Y m w 1- O 0 LL w cc 0 z w 0 I D w O w S Q H CO z O N (n w p L11 J J 2 TOTAL: 27,497 N Lf) to DRAWN BY 0 W -J U (1) I I CO CO H CO 111 cN c) 0 00 z 0^' Q ciU)`� J J a J co cc a D z • J U)co00_