Loading...
HomeMy WebLinkAboutPermit D12-245 - SUNWOOD CONDOMINIUMS - CARPORTS REROOFSUNWOOD CONDOS CARPORT REROOF 15235 SUNWOOD BL D12-245. City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 8141401020 Address: 15141 SUNWOOD BL TUKW Suite No: Project Name: SUNWOOD CONDOS - CARPORTS REROOF Permit Number: D12 -245 Issue Date: 08/08/2012 Permit Expires On: 02/04/2013 Owner: Name: SUNWOOD CONDOMINIUMS Address: C/O SUHRCO RESIDENTIAL PROP , 10655 NE 4TH ST STE 711 98004 Contact Person: Name: TIM LONG Address: PO BOX 65181 , SHORELINE WA 98155 Contractor: Name: CONSOLIDATED GTR & SET MTL LLC Address: 16751 BURKE AV N , SHORELINE WA 98133 Contractor License No: CONSOGS902RN Lender: Name: Address: Phone: 206 408 -1848 Phone: Expiration Date: 12/15/2012 DESCRIPTION OF WORK: TWO ADDRESSES: 15141 SUNWOOD BL (PKG SPOTS 22 -27) 15195 SUNWOOD BL (PKG SPOTS 26 & 57) SCOPE OF WORK: REROOF OF CARPORT STRUCTURES REMOVE GRAVEL AND ROOF DOWN TO PLYWOOD. REMOVE AND REPLACE RO'1 i ED PLYWOOD (IF NECESSARY). INSTALL GRANULATED TORCHDOWN ROOF. REPLACE EXISTING DRAINS WITH NEW AND ADD 1 NEW TO EACH CARPORT. Value of Construction: $6,425.00 Fees Collected: $369.97 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0026 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -245 Printed: 08 -09 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N / Permit Center Authorized Signature/ L.. Date: I hereby certify that I have read an governing this work will be compli Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pie- e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 1/f/44(_ Print Name: (77-12-1 vIrv 4-D Date: 8/9(r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IBC -7/10 012 -245 Printed: 08 -09 -2012 7: All construction noise to be in complianifilith Chapter 8.22 of the City of Tukwila Muni Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDPI'IONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi- purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -245 Printed: 08 -09 -2012 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 8141400000 Address: 15235 SUNWOOD BL TUKW Suite No: Project Name: SUNWOOD CONDOS - CARPORTS REROOF Permit Number: D12-245 Issue Date: 08/08/2012 Permit Expires On: 02/04/2013 Owner: Name: SUNWOOD CONDOMINIUMS Address: C/0 SUHRCO RESIDENTIAL PROP , 10655 NE 4TH ST STE 711 98004 Contact Person: Name: TIM LONG Address: PO BOX 65181 , SHORELINE WA 98155 Contractor: Name: CONSOLIDATED GTR & SHT MTL LLC Address: 16751 BURKE AV N , SHORELINE WA 98133 Contractor License No: CONSOGS902RN Lender: Name: Address: Phone: 206 408 -1848 Phone: Expiration Date: 12/15/2012 DESCRIPTION OF WORK: REROOF OF CARPORT STRUCTURES (SPACES 22 TO 27 AND 57 & 58) REMOVE GRAVEL AND ROOF DOWN TO PLYWOOD. REMOVE AND REPLACE ROTTED PLYWOOD (IF NECESSARY). INSTALL GRANULATED TORCHDOWN ROOF. REPLACE EXISTING DRAINS WITH NEW AND ADD 1 NEW TO EACH CARPORT. Value of Construction: $6,425.00 Fees Collected: $369.97 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0026 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12-245 Printed: 08 -08 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: orlUel/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfonance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: "(4/5/(--- [ ,4, t Date: Print Name: /% This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IBC -7/10 D12 -245 Printed: 08 -08 -2012 7: All construction noise to be in complian th Chapter 8.22 of the City of Tukwila Muni Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi- purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D12 -245 Printed: 08 -08 -2012 CITY OF TUKi9 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov Building Pe No. Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 5.1 3 r S w 0 Da 61 Vct , T AL,A.); I6._ / ta)Vl King Co Assessor's Tax No.: Site Address: I Sd 3S $U.'1 op-ph 61 Vc& (o. q in k$' Suite Number: Floor: Tenant Name: 5i,LA (A) eO A Cs 1/1 ALS PROPERTY OWNER Name: 5v4-4t wo-o A C -XI) S Address: 1 5-•:2 3 s 6-4,tA4 1,)o-DA 61 va City: Tikki.z i (o_ State: ail Zip:cisi Ire CONTACT PERSON - person receiving all project communication Name: ...r wl Address: 9,0.130y_ io, (kI City: G vues State: 0.0 Zip:lid ss- Phone: 11-A5-/x60 -0400 Fax. fib- - Ia94, Email: l-% v►'1 P C 11501 i 1rkA 96 w1 . Lam GENERAL CONTRACTOR INFORMATION Company Name: Address: t9,0 -60Y- bS) 1 , City: SVareji vie., State: oil_ Zip: 9 icI Phone b_40Ff-1 {'irFax:� ,..} - Ia.9(0 Contr Reg o �c.o.: 41saG59oa tui Exp Date: lam- is-. la. Tukwila Business License No.: 6ik.5, e19 34,4w. H:Wpplications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh New Tenant: ❑ Yes .. No ARCHITECT OF RECORD B Name: ,5:.<1.". )C 7,44... A con, (i,6 Q. SSG Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD B Name: ,5:.<1.". )C 7,44... A con, (i,6 Q. SSG Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) B Name: ,5:.<1.". )C 7,44... A con, (i,6 Q. SSG Address: City: State: Zip: 10-47 Page 1 of 4 BUILDING PERMIT INFORMATION — 206 - 431 -3670 / OD Valuation of Project (contractor's bid price): $ r�17 �� Existing Building Valuation: $ Describe the scope of work (please provide detailed information): R era d & G deif- LLE.z_ A-,U D / t {D q- 114 op / of 1M it) k) 7-o /I Lc/ik)0o , 1hp Al-/4 1Qs G.4-(x 61'1-eN f Ly cVisoa (1.F i1 j) I4 7-4-LC G2A�JVL 41-rrFA TD -01 Da WA) ' &;c-. �%pG�9G� tax rfri.ve ,¢ev�d r,. ITtil .tl €k> AA/? /-- h ! N tJ o (410/ e A6+2T W / • Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport I i 3 0 2.4 6 ( Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO/NATION - 206 - 433 -0179 • Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ...Valley View ❑ ...Sewer Availability Provided ❑... Highline ❑ ... Renton 0... Renton 0... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) 0... Geotechnical Report ❑ .. Bond 0... Insurance 0... Easement(s) ❑ ... Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right -of -way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage 0... Abandon Septic Tank ❑... Curb Cut 0... Pavement Cut ❑... Looped Fire Line ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public VI VI 0... Grease Interceptor ❑... Channelization ❑...Trench Excavation ❑... Utility Undergrounding WO # (2) " WO # (3) " WO # " WO # (2) " WO # (3) " WO # WO # ❑ .. Deduct Water Meter Size " Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms- Applications On Line \2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES — • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN( OR AUTIORIZED AGENT: Signature: Print Name: Mailing Address: igre ,G6( 6c /P H:\Applications\Forms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx Revised: February 2012 bh Date: 2) 7/ 9,0)2, Day Telephone: � ‘d‘64?)-- 6j) ? S/ bye /i /te (N4 Q�/�Zi'�" City State p Page 4 of 4 i • fib City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.Tukwila WA.2,ov RECEIPT Parcel No.: Permit Number: D12-245 Address: 15235 SUNWOOD BL TUKW Status: PENDING Suite No: Applied Date: 07/27/2012 Applicant: SUNWOOD CONDOS - CARPORTS REROOF Issue Date: Receipt No.: R12 -02209 Initials: WER User ID: 1655 Payment Amount: $369.97 Payment Date: 07/27/2012 09:09 AM Balance: $0.00 Payee: CONSOLIDATED GUTTER & SHEET TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 010745 ACCOUNT ITEM LIST: Description 369.97 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $369.97 221.50 143.97 4.50 doc: Receiot -06 Printed: 07 -27 -2012 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: S? IA ILA 1nC`?� (iu „..oc Type of Inspection: + iNfA! Address: ISIS t t11■c400r Date Called: Special Instructions: Date Waann�ted:. a.m. Requester: Phone No: .(--)(. - -.255 — 6, 7Li K Approved per applicable codes. Corrections required prior to approval. 3 COMMENTS: �Or r^► 't' l je. Inspecto .' Date EIINSPECTION FEE REQUIRED. Prior t• next inspection, fee must be paifl at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tZ (206) 431 - 3670..\ Permit Inspection Request Line (206) 431 -2451 Proje,cte JAcej 0 6 jl 60,46i TvP of Inspect n: 5 _ ��0 cp Date Called: Special Instructions: Z —O (�_ O S S z2/ ?A .S9 S8 Date Wanted: �a ar- /�- P.m. Requester: Phone No: '475--?5-6-704q9 Approved per applicable codes. ElCorrections required prior to - rye -`-- (A) Inspecto 0,ck x Date:, REINSPECTION FEE REQUIRED. Prior to next inspection,` fee; must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reiiispection:. Owner: Owner Address: Building Address: # of Squares: CT Product Specification No: Description of Building Use: Applicator: Roof Completion Date: Applicator's Address: Applicator's Phone: Sunwood Condos —15209 Sunwood Blvd. Tukwila, WA 98188 Sunwood Condos -15195 Sunwood Blvd. Tukwila, WA 98188 4 squares Flintlastic GTA Carports — parking stall 456 & 57 Consolidated Roof & Gutter, LLC August 11,2012 PO Box 65181 Shoreline, WA 98155 206 - 408 -1848 Ui 10-year X1,..12-year ` 2-year ,01 15 -year • 20 -year DJ 25-year Coverage CertainTeed Corporation (CT) hereby warrants the roof membrane installed at the above address, subject to the following terms, conditions, limitations and exclusions, for the period checked above from the date of completion of the roof membrane installation. 11 during the duration of this limited warranty, a manufacturing defect in the roof membrane causes a leak, CT or its designated roofing contractor will, at CT's sole discretion, repair or replace the roof membrane materials only as necessary to restore it to a watertight condition. Only manufacturing defects in the roof membrane that cause leaks are covered by this limited warranty CTs MAXIMUM LIABILITY during the first year of this warranty is the original cost of the CT membrane materials only. After the first year. CT's maximum liability is the original cost of the CT materials used on the roof reduced by 4% for 25 -year warranties, 5% for 20-year warranties. 6.67% for 15 -year warranties, 8.3% for 12 -year warranties and 10% for 10 -year warranties during each subsequent year, less any costs previously incurred by CT for repair or replacements. In no event, however, will CT be responsible for any costs related to the removal or abatement of any asbestos present in any existing roof system to which the CT root membrane is applied. Root membrane, as used herein, shall include the following components: applicable base sheet(s), interplies and cap sheets) (with appropriate roof coating of surfaces) required for the above - selected warranty, and asphalt material between layers when required, if applied per Cis Commercial Roof Membrane Manual specification. Roof components which are cot part of the roof membrane and hence not covered by this limited warranty include, but not limited to the following: underlying roof deck, insulation, vapor retarders, fasteners, metal work, drains, pitch pans, expansion joints, skylights, vents, plastic accessories, any flashing, decorative or reflective coating, surfacing and/or any aggregates. Exclusions from Coverage This limited warranty does not cover leaks, damages or Injuries of any type, including, but not limited to, damage to roof insulation, roof decks or other bases over which the CT products are applied, attributable directly or indirectly to any of the following: 1. Natural disasters. including, but not limited to, cyclones, tornadoes. hurricanes or other winds exceeding Force 9 on the Beaufort scale, lightning, earthquakes, flood, hail or fire. 2. Falling objects, civil insurrection. war, riot or vandalism. 3. Settlement, deflection, movement, moisture content, inadequate attachment, or other deficiencies of the roof deck, pre - existing roof system, walls, foundations or any other part of the building structure, insulator or other materials underlying the roof membrane. 4. Failure of the roof membrane caused or contributed by a. Maintenance, repair or work on the roof unrelated to the root membrane, such as, but not limited to mechanical, electrical, plumbing, etc.; b. infiltration or condensation of moisture in, through or around the walls, copings and metal components. pitch pans, building structure or underlying or surrounding materials; c. Traffic of any nature or use of the roof surface as a storage area. walking or recreational surface or for any other similar purpose; d. Movement or deterioration of metal work used in conjunction with the root membrane, e. Deposits of solids or liquids which may cause deterioration of the root membrane f. Building design or construction: g. Lack of positive drainage, to completely remove water from the roof membrane per NRCA guidelines; or h. Installation over a wet surface or substrate. 5. Failure to adhere to CT's root maintenance program (see CT's Roof Maintenance Form). 6. Unauthorized application on excluded buildings or structures (see CT's General Requirements). 7. Any change in the building's basic usage unless approved in advance in writing by CT. 8. Any use of roofing material of any kind or nature not approved in CT's Commercial Roof Systems Manual in effect at the time of installation. 9. Placement of any additional structures on the roof membrane (such as, but not limited to, equipment or framework used in connection with air conditioning units, Iran i and/or water towers). 10. failure to maintain the watertight integrity of the roof system. (Owner must make repairs to non - warranted items that affect the watertight integrity of the roof system). This limited warranty does not cover fading or other changes in color to the roof membrane as a result of airborne pollutants or other causes, including, but not limited to. natural fading. Unapproved Repairo, diteratione, Additiono or Deletions All repairs, alterations, deletions or additions to any aspect o1 the roof. or any material contiguous thereto, must have prior written approval of CT's Commercial Warranty Department ( CertainTeed Roofing Products Group, Commercial Warranty Department, 1400 Union Meeting Road, PO Box 1100, Blue Bell, PA 19422, (800) 396 - 8134). If Owner, without prior written consent of CT, makes or permits any repairs, alterations, deletions or additions to the root, all of CT's obligations, duties and coverage under this limited warranty will terminate and the limited warranty will be voided. Bfotice of Claims Any claim or request for CT to perform under this limited warranty must be made by Owner in writing within thirty (30) days of discovery of the defect, and Owner must send original proof of purchase (Contract or invoice from roofer for service, product or work completed does not constitute Proof of Purchase of CT products. Original Proof of Purchase is required and best obtained from dealer) and samples that demonstrate the alleged manufacturing defect to CT's Commercial Warranty Department. This notice of claim must include a general description of the alleged defect. Owner shall grant access to the entire roofing system as neces- sary for CT to investigate a claim. If access is not granted, CT shag have the right to determine, at its sole discretion, that this limited warranty is void as to that portion of the roof membrane to which access is denied. NOTE: In the event an emergency condition exists which requires immediate repair to avoid damage to the building or its contents, Owner may make essential temporary repair(s) performed by a qualified rooter. CT will only reimburse Ovmer for essential temporary repair expenses that would have been covered under this limlted warranty. RNodificationa • Only CT's Commercial Warranty Department is authorized to modify coverage provided by this limited warranty. issuance of this limited warranty or review or inspection of plans, the building or product application by a CT representative does not waive any exdusions or conditions of this limited warranty. Application of a roof membrane that deviates from CT's Commercial Roof Systems Manual specifications voids coverage. unless prior written approval is provided by CT's Commercial Warranty Department. Transferability of NHarranty This limited warranty may be transferred to a subsequent owner only if CT's Commercial Warranty Department is notified, at the above listed Blue Bell address, within thirty (30) days of real estate title transfer and upon payment of the applicable transfer tee. Failure of the Owner and subsequent owner to transfer this limited warranty pursuant to these stated conditions terminates CT's warranty obligations and the limited warranty will be voided. Condition Pertaining to tAlarranty Issuance This limited warranty applies to root membranes installed during the calendar year of 2012 and shall become effective following complete installation of the roof membrane and payment in full to the roofing contractor. (The warranty in effect at the time the material is originally installed is the applicable warranty.) Warranty and Limitation of Remedies THIS DOCUMENT CONSTITUTES THE EXCLUSIVE WARRANTIES AND REMEDIES PROVIDED BY CERTAINTEED. THE WARRANTIES AND REMEDIES CONTAINED IN THIS DOCUMENT ARE EXPRESSLY IN LIEU OF ANY AND ALL OTHER OBLIGATIONS, GUARANTEES AND WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED BY STATUTE OR AT LAW. STATE OR PROVINCIAL LAW WILL DETERMINE THE PERIOD OF TIME FOLLOWING THE SALE THAT A PROPERTY OWNER MAY SEEK A REMEDY UNDER THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CERTAINTEED'S OBLIGATIONS, RESPONSIBILITIES AND LIABILITY SHALL BE LIMITED TO REPAIRING OR REPLACING THE DEFECTIVE ROOF MEMBRANE PRODUCT AS SET FORTH IN THIS LIMITED WARRANTY. IN NO EVENT SHALL CERTAINTEED BE LIABLE FOR ANY SPECIAL. INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE PROPERTY, THE BUILDING OR ITS CONTENTS. OR FOR INJURY TO ANY PERSONS THAT MAY OCCUR AS A RESULT OF THE USE OF THE ROOF MEMBRANE PRODUCT OR AS A RESULT OF THE BREACH OF THIS WARRANTY. IF YOUR STATE OR PROVINCE DOES NOT ALLOW EXCLUSIONS OR LIMITATIONS OF SPECIAL, INDIRECT, INCIDENTAL OR CONSEOUENTIAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. IN NO EVENT SHALL CERTAINTEED'S TOTAL LIABILITY ARISING OUT OF OR RELATED TO THE ROOF MEMBRANE PRODUCT OR THIS WARRANTY EXCEED THE COST TO THE OWNER OF THE ROOF MEMBRANE PRODUCT OF THE ORIGINAL INSTALLATION. This limited warranty may not be modified, altered or expanded by anyone, including product distributors, dealers, sellers, installers and/or CertainTeed field representatives. This limited warranty gives you specific legal rights, and you may also have other rights which vary iron State to State or Province to Province. Agreement to Binding Arbitration Any and all claims. disputes and other matters in question that may occur between Owner, the contractor, and/or CT, arising out of, in connection with, or relating to this limited warranty or breach thereof, shall be submitted to BINDING ARBITRATION for resolution. The arbitration shall be conducted by the American Arbitration Association under its Construction Industry Arbitration Rules then in effect unless the parties mutually agree otherwise. This agreement to arbitrate shall be specifically enforceable under the Federal Arbitration Act, 9 U.S.C. § 2 or the applicable state arbitration laws. Tire award rendered by the arbitrator shall be final, and judgment may be entered upon such award in accordance with applicable law in any court having jurisdiction thereof. Eueminotion or Inspection Issuance of this limited warranty or roof inspections made by CT or an authorized agent of CT do not constitute an approval of the roof, roof design plans or specifications, or construction or installation ei the roof. CT does not practice engineering or architecture. Roof designs, construction plans or installation of the roof system should be approved by Owner or Owner's professional. Note: All referenced documents/forms are available at www.certainteed.eom. CertainTeed Corporation, 750 E. Swedestord Road. P.O. Box 860, Valley Forge. PA 19482 Rev 3/2012 02008 CertainTeed Corporation, COMM -209 CITYOFTUt Wfl AUG 15 2812 EAR A / (Si Owner: Owner Address: Building Address: E of Squares: CT Product Specification No: Description of Building Use: Applicator: Roof Completion Date: Applicator's Address: Applicator's Phone: Sunwood Condos —15209 Sunwood Blvd. Tukwila, WA 98188 Sunwood Condos -15141 Sunwood Blvd. Tukwila, WA 98188 10 squares Flintlastic GTA Carports — parking stall 422 - 27 Consolidated Roof & Gutter, LLC August 11,2012 PO Box 65181 Shoreline, WA 98155 206 -408 -1848 Qf 10 -year j2 -year /Lj 15 -year la 20 -year U 25 -year Coverage CertainTeed Corporation (CT) hereby warrants the roof membrane installed at the above address, subject to the following terms, conditions, limitations and exclusions, for the period checked above from the date of completion of the roof membrane installation. if during the duration of this limited warranty, a manufacturing defect In the roof membrane causes a leak, CT or Its designated roofing contractor will, at CT's sole discretion, repair or replace the roof membrane materials only as necessary to restore it to a watertight condition. Only manufacturing defects in the roof membrane that cause leaks are covered by this limited warranty. CT's MAXIMUM LIABILITY during the first year of this warranty is the original cost of the CT membrane materials only. Atter the first year, CT's maximum liability is the original cost of the CT materials used on the roof reduced by 4% for 25 -year warranties, 5% for 20 -year warranties, 6.67% for 15 -year warranties, 8.3% for 12 -year warranties and 10% for 10 -year warranties during each subsequent year, less any costs previously incurred by CT for repair or replacements. In no event, however, will CT be responsible for any costs related to the removal or abatement of any asbestos present in any existing roof system to which the CT roof membrane Is applied. Roof membrane, as used herein, shall Include the following components: applicable base sheet(s), lnterplles and cap sheet(s) (with appropriate roof coating of surfaces) required for the above - selected warranty, and asphalt material between layers when required, if applied per CTs Commercial Roof Membrane Manual specification. Roof components which are not part of the roof membrane and hence not covered by this limited warranty include, but not limited to the following: underlying roof deck, insulation, vapor retarders, fasteners, metal work, drains, pitch pans, expansion joints, skylights, vents, plastic accessories, any flashing, decorative or reflective coating, surfacing and/or any aggregates. Euclusione from Coverage This limited warranty does not cover leaks, damages or Injuries of any type, including, but not limited to, damage to roof insulation, roof decks or other bases over which the CT products are applied, attributable directly or indirectly to any of the following: 1. Natural disasters, including, but not limited to, cyclones, tornadoes, hurricanes or other winds exceeding Force 9 on the Beaufort scale, lightning, earthquakes, flood, hail or fire. 2. Falling objects, civil insurrection. war, riot or vandalism. 3. Settlement, deflection, movement, moisture content, inadequate attachment, or other deficiencies of the roof deck, pre - existing roof system, walls, foundations or any other part of the building structure, insulation or other materials underlying the roof membrane. 4. Failure of the roof membrane caused or contributed by: a. Maintenance, repair or work on the roof unrelated to the roof membrane, such as, but not limited to mechanical, electrical, plumbing, etc.; b. Infiltration or condensation of moisture in, through or around the walls, copings and metal components, pitch pans, building structure or underlying or surrounding materials; c. Traffic of any nature or use of the roof surface as a storage area, walking or recreational surface or for any other similar purpose; d. Movement or deterioration of metal work used in conjunction with the root membrane; e. Deposits of solids or liquids which may cause deterioration of the root membrane, 1. Budding design or construction; g. Lack of positive drainage, to completely remove water from the roof membrane per NRCA guidelines; or h. Installation over a wet surface or substrate. 5. Failure to adhere to CT's roof maintenance program (see CT's Roof Maintenance Form). 6. Unauthorized application on excluded buildings or structures (see CT's General Requirements). 7. Any change in the building's basic usage unless approved in advance in writing by CT. 8. Any use of roofing material of any kind or nature not approved in CT's Commercial Roof Systems Manual in effect at the time of installation. 9. Placement of any additional structures on'the roof membrane (such as, but not limited to, equipment or framework used in connection with air conditioning units, transmission and/or reception devices, signs and/or water towers). 10. Failure to maintain the watertight integrity of the roof system. (Owner must make repairs to non - warranted items that affect the watertight Integrity of the roof system). This limited warranty does not cover fading or other changes in color to the roof membrane as a result of airborne pollutants or other causes, including, but not limited to, natural fading. Unapproved Repairs, Alterations, Additions or Deletions All repairs, alterations, deletions or additions to any aspect of the roof. or any material contiguous thereto, must have prior written approval of CT's Commercial Warranty Department (CertainTeed Roofing Products Group, Commercial Warranty Department, 1400 Union Meeting Road, PO Box 1100, Blue Bell, PA 19422, (800) 396 - 8134). If Owner, without prior written consent of CT, makes or permits any repairs, alterations, deletions or additions to the root, all of CT's obligations, duties and coverage under this limited warranty will terminate and the limited warranty will be voided. Rlotice of Claims Any claim or request for CT to perform under this limited warranty must be made by Owner in writing within thirty (30) days of discovery of the defect, and Owner must send original proof of purchase (Contract or invoice from roofer for service, product or work completed does not constitute Proof of Purchase of CT products. Original Proof of Purchase is required and best obtained from dealer) and samples that demonstrate the alleged manufacturing defect to CT's Commercial Warranty Department. This notice of claim must Include a general description of the alleged defect. Owner shall grant access to the entire roofing system as neces- sary for CT to investigate a claim. If access is not granted, CT shall have the right to determine, at its sole discretion, that this limited warranty is void as to that portion of the roof membrane to which access is denied. NOTE: In the event an emergency condition exists which requires immediate repair 1e avoid damage to the building or Its contents, Owner may make essential temporary repair(s) performed by a qualified roofer. CT will only reimburse Owner for essential temporary repair expenses that would have been covered under this limited warranty. Modifications Only CT's Commercial Warranty Department is authorized to modify coverage provided by this limited warranty. Issuance of this limited warranty or review or Inspection of plans, the building or product application by a CT representative does not waive any exclusions or conditions of this limited warranty. Application of a roof membrane that deviates from CT's Commercial Roof Systems Manual specifications voids coverage, unless prior written approval Is provided by CT's Commercial Warranty Department. Transferability of Warranty This limited warranty may be transferred to a subsequent owner only if CT's Commercial Warranty Department Is notified, at the above listed Blue Bell address, within thirty (30) days of real estate title transfer and upon payment of the applicable transfer fee. Failure of the Owner and subsequent owner to transfer this limited warranty pursuant to these stated conditions terminates CT's warranty obligations and the limited warranty will be voided. Condition Pertaining to Warranty Issuance This limited warranty applies to roof membranes installed during the calendar year of 2012 and shall become effective following complete installation of the roof membrane and payment in full to the roofing contractor. (The warranty in effect at the time the material is originally installed is the applicable warranty.) Warranty and Limitation of Remedies THIS DOCUMENT CONSTITUTES THE EXCLUSIVE WARRANTIES AND REMEDIES PROVIDED BY CERTAINTEED. THE WARRANTIES AND REMEDIES CONTAINED IN THIS DOCUMENT ARE EXPRESSLY IN LIEU OF ANY AND ALL OTHER OBLIGATIONS, GUARANTEES AND WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED BY STATUTE OR AT LAW. STATE OR PROVINCIAL LAW WILL DETERMINE THE PERIOD OF TIME FOLLOWING THE SALE THAT A PROPERTY OWNER MAY SEEK A REMEDY UNDER THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CERTAINTEED'S OBLIGATIONS, RESPONSIBILITIES AND LIABILITY SHALL BE LIMITED TO REPAIRING 013 REPLACING THE DEFECTIVE ROOF MEMBRANE PRODUCT AS SET FORTH IN THIS LIMITED WARRANTY. IN NO EVENT SHALL CERTAINTEED BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL 011 CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE PROPERTY, THE BUILDING OR ITS CONTENTS, OR FOR INJURY TO ANY PERSONS THAT MAY OCCUR AS A RESULT OF THE USE OF THE ROOF MEMBRANE PRODUCT OR AS A RESULT OF THE BREACH OF THIS WARRANTY IF YOUR STATE OR PROVINCE DOES NOT ALLOW EXCLUSIONS OR LIMITATIONS OF SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. IN NO EVENT SHALL CERTAINTEED'S TOTAL LIABILITY ARISING OUT OF OR RELATED TO THE ROOF MEMBRANE PRODUCT OR THIS WARRANTY EXCEED THE COST TO THE OWNER OF THE ROOF MEMBRANE PRODUCT OF THE ORIGINAL INSTALLATION. This limited warranty may not be modified, altered or expanded by anyone, including product distributors, dealers, sellers, installers and/or CertainTeed field representatives. This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State or Province to Province. Agreement to Binding Arbitration Any and all claims, disputes and other matters In question that may occur between Owner, the contractor, and /or CT, arising out of, in connection with, or relating to this limited warranty or breach thereof, shall be submitted to BINDING ARBITRATION for resolution. The arbitration shall be conducted by the American Arbitration Association under its Construction Industry Arbitration Rules then in effect, unless the parties mutually agree otherwise. This agreement to arbitrate shall be specifically enforceable under the Federal Arbitration Act, 9 U.S.C. § 2 or the applicable state arbitration laws. The award rendered by the arbitrator shall be final, and judgment may be entered upon such award in accordance with applicable law in any court having jurisdiction thereof. Examination or Inspection Issuance of this limited warranty or roof inspections made by CT or an authorized agent of CT do not constitute an approval of the root, roof design plans or specifications, or construction or installation of the roof. CT does not practice engineering or architecture. Roof designs, construction plans or installation of the roof system should be approved by Owner or Owner's professional. Note: All referenced documents/forms are available at www.certaiMeed.com. CertainTeed Corporation, 750 E. Swedesford Road, P.O. Box 860, Valley Forge, PA 19482 Rev 3/2012 ©2008 CertainTeed Corporation, COMM -209 Name: 3.1-)Ai -7) Site: Site: H: Ref. S '70-41T REQUIRED FOR: by: le Mechanical Company: Date: Mail E-Mail F: Client File #: M: No changes shall he mariato_the_scope of work vt.tftut prior approval of ulkwirajeuilding Division. f4077: 1-1,-nvisinns will require a new plan submittal _ 11 CIR VENT lumbing B V-NTS RE 50Gras Piping RVT (13.y of Tukwil s 'NIA/ Rif KW e l. la OA. 6,11 v LL PIPE BOOTS NCO LDO EPO 1- 2° 4" ELEC. POST PAN STEP RTW CSM VALLEY DRIP COLOR GUTTERS EXT 0 SPG 0 FM COLOR NOTES: 3. • • ' . 1 , , - I t ! . I • ' • 1 t : 1 , REVIEWED F CODE COMPLI APPROVE AUG 0 3 2 1 • I -7. • r- - .1 • ; • -1 -- .4.- . . I- . t _.; _ t .._ • ./ ! 4 • t • I •-1-•• I • : _ _• , _ . . I 1 • 1. I i• H - i ' • 4 1 1 it I 1 1 4 1 1 I 1 • a r 1 I • , • 1 t -4 1 --IL - - - T • Pettnit FL •• 1 ' rm.fidw a val is subject_to_fgairsanctorniseona: - • , 1, documents does riot _authetile_ caiy do.ptediXtocliotorcralaricEltecziPt is.acknowlediedz---- - : t I — .rt --- — --! -- :Data: S SO CO HTO L •R ttrof_Tukwita_ A A (I3MIN4 D DIVISION PLCMNT 0 STORIES 1 2 3 4 CIF OK 0 NEEDED 0 ASP 0 CEM 0 OTHER 0 SAT YO NO JUL 2'7 2012 OPEN 0 BOX EV 0 PACK 0 LOAD 0 PLY ONLY :3 10 0 124 pERMIT CENTER 1 -- I BUILDING DIVISION SPLY 0 SPLIT 0 SOL 0 PLY 0 S/LAP 0 OSB 0 AIR INTAKE T-OFF PITCH 81781- 8017 (9o<0 RECEIV VM au1la.wLIS '18159 XVH. Od Consolidated FILE' COPY Gutter & Sheet Metal, LLC permit N®. PO Box 65181, Shoreline WA 98155 (206) 408 -1848 Customer File #: 1487 Date: 7/19/2012 ICustomerMallirig Adds 1 Re -roof Parking Space's 57 & 58 Gregory Dill Consolidated GSM offers to fumish all materials and perform all labor as described below, subject to our Standard Terms and Conditions as set forth on the reverse side hereof: !Phase` f tfYork: Prepare grounds by placing sheeting and tarps around tear off areas to protect plants and belongings. (Attic not included) Scrape off existing one layer gravel and dispose of all debris. Tear off existing one layer roofing to sub -deck and dispose of all debris. Pack out material to container. Load roof materials. Additional layers of roofing will be added to agreed price. Inspect sub -deck for necessary replacement of wood components to accept new roofing. Replace 1/2" CDX plywood at $52.00 per sheet (All materials & labor included) Any unforeseen woodwork will be performed at $65.00 per man hr. plus actual material costs upon homeowner approval Our jobsite will be left in a clean orderly manner with a watertight seal at the end of each day. Phase :11111 'rk Install base sheet underlayment. Install 26g. baked enamel fascia metal. Apply single -ply torchdown roofing system in accordance with Manufacturers' specifications (Granulated) Replace existing 2" scupper drain with same. Install one new 3" scupper drain and downspout. ttl_Wt r c _ F l Thoroughly dean grounds and sweep with magnet. AUG 0 3 2012 Perform final inspection. �JopLocation � .:: r -� Sunwood Apt's -Prkg.spots 57 &58 1ProposstOptions 1 1. Lyr Smooth Torchdown 12yr $1,875.00 + tax & permit fees (if required) The preceding proposal options are subject to our Standard Terms and Conditions on the reverse side hereof. Any alterations or deviations from the work described above will be performed only upon the direction of the Customer, and Customer agrees to pay Consolidated's standard charges for such work. Terms:.: Estimated starting date of shall be subject to availability of materials, manpower and weather conditions. This proposal is good for 20 days from the date first written above, and shall automatically lapse if not accepted in writing by Customer by that time. Our Terms are 1/3 at contract signing, balance upon completion. By: , Consolidated Customer hereby agrees to accept this foregoing Proposal this day of , 20 By: Customer Signature Date: REVIEWED FOR CODE COMPLIANCE APPROVED city of Tukwila BUILDING DIVISION RECEIVED JUL 27 2012 PERMIT CENTER Customer File #: Consolidated Gutter & Sheet Metal, LLC PO Box 65181, Shoreline WA 98155 (206) 408 -1848 1487 Date: 6/18/2012 (C ustomer?Maping Address •=;) Steve Gregory Consolidated GSM offers to furnish all materials and perform all labor as described below, subject to our Standard Terms and Conditions as set forth on the reverse side hereof: Prepare grounds by placing sheeting and tarps around tear off areas to protect plants and belongings. (Attic not included) Scrape gravel off existing roof. Tear off existing one layer roofing to sub -deck and dispose of all debris. Pack out material to container. Load roof materials. Additional layers of roofing will be added to agreed price. Inspect sub -deck for necessary replacement of wood components to accept new roofing. Replace 1/2" CDX plywood at $52.00 per sheet (All materials & labor included) Any unforeseen woodwork will be performed at $65.00 per man hr. plus actual material costs upon homeowner approval Our jobslte will be left in a clean orderly manner with a watertight seal at the end of each day. (Phase II Work Install base sheet underlayment. Install 26g. baked enamel fascia metal. Apply single -ply torchdown roofing system in accordance with Manufacturers' specifications (Granulated) Install new 2" scupper drains. �Pi>ass IN;Work „ , 1 Blow off roof, clean gutters and downspouts Thoroughly clean grounds and sweep with magnet. Perform final inspection. (JobLocatfon Sunwood Apt's. (Carport) Tukwila WA IProposatOpttions `j 15141 Phase 2 (carport in front of E budding) 1 Lyr Granulated Torchdown 12yr $4,550.00 + tax & permit fees (if required) The preceding proposal options are subject to our Standard Terms and Conditions on the reverse side hereof. Any alterations or deviations from the work described above will be performed only upon the direction of the Customer, and Customer agrees to pay Consolidated's standard charges for such work. Estimated starting date of shall be subject to availability of materials, manpower and weather conditions. This proposal is good for 20 days from the date first written above, and shall automatically (apse if not accepted in writing by Customer by that time. Our Terms are 1/3 at contract signing, balance upon completion. By: , Consolidated Customer hereby agrees to accept this foregoing Proposal this day of , 20 By: Customer Signature Date: Consolidated Roof & Gutter License# CONSOGS902RN Phone: (206) 408 -1848 Cell: (425) 780 - 0400 info consolidatedgsm.com General Contractor Information & Contact Sheet Consolidated Gutter & Sheet Metal, LLC PO Box 65181 [ 14080 - 24th Ave. NE Shoreline, WA 98125) Shoreline, WA 98155 Phone: FAX State Contractor License State ES Reference Labor & Industries Acct Fed Tax ID: UBI Compliance Depot Vendor General Brian Keene Tim Long Gigi Gable- Martinson Kyle Williams Uriostegui :melody Insurance - Primary: Umbrella: Vehicles: Bond Policy: (206) 408 -1848 (206) 774 -1296 138' i #CONSOGS902RN #396145 -00 5 #201,822 -00 27- 3926120 603 - 054 -384 #608464 Email: info@consolidatedcism.com brian a.consolidatedgsm.com timOconsolidatedgsm.com gigi(consolidatedgsm.conv kvle(cconsolidatedgsm. com tomas(a.consolidatedgsm.com melodvCa.consolidatedgsm.com Carrier First Mercury Insurance Co. Ohio Casualty Ohio Casualty US Fire Insurance Co. Mobile Phone: (206) 300 -9138 (425)780-0400 (425) 275 - 2195 (425) 876 -2649 (206) 898 - 8408 (425) -280 -7899 9-S3- 3tt Fr 'tik -S Policy# Amount FMWA001939 $1,000,000.00 BEO 028087620 $1,000,000 00' BAS 54673239 n/a 615978760 ! $12,000:00. ineering or Architecture, neither the Issuance of the warranty nor any review of the project documents, conditions by Polyglass Representatives shall constitute any acceptance or implied warranty by Polyglass of construction or in any way constitute an extension of the terms and conditions of the Polyglass Warranty. for the benefit of Polyglass. �.. YATUflOORNG MAIMI& A. J Issru n 5T5TIM F LEC POLYGLASS ROOF SYSTEM5PerrA •--- PY moon- Below are the minimum layers required for the respective warranty duration, -" ""Hortt to errors and orr '. Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year Roof 15 Year Roof* 20 Year Roof* Torch Base G2 mechanically attached G2 mechanically attached Polyglass Base mechanically attached or torch Ply N/A Polyglass Base torched Polyflex S torched Cap Polybond G, Polyflex G, torched Polybond G, Polyflex G, torched Polyflex G torched Self Adhered Base Elastobase V mechanically attached Elastobase V mechanically attached Elastobase V mechanically attached Ply N/A Elastoflex SA V Self Adhered Elastoflex SA V - 2 layers Self Adhered Cap Polyflex SA P, Elastoflex SA P, or Polykool Self Adhered Polyflex SA P, Elastoflex SA P, or Polykool Self Adhered Polyflex SA P, Elastoflex SA P, or Polykool Self Adhered Hot Mop / Cold Process Base G2 mechanically attached, hot mop, or cold process G2 mechanically attached, hot mop, or cold process Elatobase V mechanically attached, hot mop, or cold process Ply N/A Elastoshield TS hot mop, or cold process Elastoshield TS hot mop, or cold process Cap Elastoflex S6 G hot mop, or cold process Elastoflex S6 G hot mop, or cold process Elastoflex 56 G hot mop, or cold process Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year LIMITED ROOFING MATERIAL WARRANTY - Prorated Material Only Warranty - available to all contractors. 10, 12, 15, & 20 Year MATERIAL & LABOR WARRANTY - Non - Prorated Material & Labor Warranty - available to Polyglass Approved Registered Contractors only. 10, 12, 15, & 20 Year ROOFING SYSTEM WARRANTY Non- Prorated NDL System Warranty (includes workmanship) - available to Polyglass Approved Registered Contractors only - all primary and secondary materials utilized within system must be supplied by Polyglass - warranty fees required. ROOFING SYSTEM WARRANTY FEE SCHEDULE 10 - Year @ $6.00 /sq or $600 minimum 12 - Year @ $8.00 /sq or $800 minimum 15 - Year @ $12.00 /sq or $1,200 minimum 20 - Year @ $15.00 /sq or $1,500 minimum Warranty requires the original installation of the roofing membrane must be installed in strict compliance with Polyglass current published specifications. Please see actual Warranty for Terms and Conditions. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2012 Polyglass does not practice Er building, or other constructio C,}sgucb�lns, aankd ,BULL �`Dyy41' IGfitYl V' :1.Yi'� I, RECEIVED JUL 27 2012 PMT PENTER • ATHIMCMIC Ili IN 811 POLYGLASS &MAIO POLYGLASS ROOF SYSTEMS UL Class A - Combustible Deck - Without Insulation or Coverboard Below are the minimum layers required for the respective warranty duration. Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year Roof 15 Year Roof* 20 Year Roof* Torch Base G2 mechanically attached G2 mechanically attached Polyglass Base mechanically attached PIy G2 mechanically attached Polyglass Base torched Polyglass Base torched Cap Polyflex G FR torched Polyflex G FR torched Polyflex G FR torched UL Listing # #6 up to 1/2" slope #6 up to 1/2" slope #6 up to 1/2" slope Self Adhered Base G2 mechanically attached followed by Elastobase V mechanically attached G2 mechanically attached followed by Elastoflex SA V FR Self Adhered G2 mechanically attached followed by Elastobase V mechanically attached G2 mechanically attached followed by Elastoflex SA V FR Self Adhered N/A Ply N/A N/A Elastoflex SA V FR Self Adhered N/A Cap Polyflex SA P FR or Elastoflex SA P FR Self Adhered Polykool Self Adhered Polyflex SA P FR or Elastoflex SA P FR Self Adhered Polykool Self Adhered UL Listing # #22 up to 1/2" slope #31 up to 1/2" slope #22 up to 1/2" slope #31 up to 1/2" slope Hot Mop Base G2 mechanically attached, or hot mop G2 mechanically attached, or hot mop N/A PIy G2 hot mop G2 hot mop Cap Elastoflex S6 G FR hot mop Elastoflex 56 G FR hot mop UL Listing 6 #9 up to 1/2" slope #9 up to 1/2" slope Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year LIMITED ROOFING MATERIAL WARRANTY - Prorated Material Only Warranty - available to all contractors. 10, 12, 15, & 20 Year MATERIAL & LABOR WARRANTY - Non - Prorated Material & Labor Warranty - available to Polyglass Approved Registered Contractors only. 10, 12, 15, & 20 Year ROOFING SYSTEM WARRANTY Non - Prorated NDL System Warranty (includes workmanship) - available to Polyglass Approved Registered Contractors only - all primary and secondary materials utilized within system must be supplied by Polyglass - warranty fees required. ROOFING SYSTEM WARRANTY FEE SCHEDULE 10 - Year @ $6.00 /sq or $600 minimum 12 - Year @ $8.00 /sq or $800 minimum 15 - Year @ $12.00 /sq or $1,200 minimum 20 - Year @ $15.00 /sq or $1,500 minimum Warranty requires the original installation of the roofing membrane must be installed in strict compliance with Polyglass current published specifications. Please see actual Warranty for Terms and Conditions. Polyglass does not practice Engineering or Architecture, neither the issuance of the warranty nor any review of the project documents, building, or other construction conditions by Polyglass Representatives shall constitute any acceptance or implied warranty by Polyglass of such plans, specifications, and construction or in any way constitute an extension of the terms and conditions of the Polyglass Warranty. Any roof inspections are solely for the benefit of Polyglass. _ WATDYDW TIN YAtCFYW AND ',MUTING smuts —. POLYGLASS ROOF SYSTEMS UL Class A - Non Combustible Deck - Without Insulation or Coverboard Below are the minimum layers required for the respective warranty duration. Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year Roof 15 Year Roof* 20 Year Roof* Torch Base G2 mechanically attached Polyflex Smooth torched Polyflex Smooth torched PIy N/A N/A Polyflex Smooth torched Cap Polyglex G FR torched Polyglex G FR torched Polyglex G FR torched UL Listing # #5 up to 1" slope #5 up to 1" slope #5 up to 1" slope Self Adhered Base N/A Elastoflex SA V FR Self Adhered N/A PIy N/A N/A Cap Elastoflex SA P FR or Polyflex SA P FR Self Adhered Elastoflex SA P FR, Polyflex SA P FR, or Polykool Self Adhered UL Listing # #27 up to 3" slope #28, #33 up to 1" slope Hot Mop Base G2 mechanically attach, or hot mop G2 mechanically attach, or hot mop PIy N/A G2 Hot mop Cap Elastoflex S6 G FR Hot mop Elastoflex S6 G FR Hot mop UL Listing # #15 up to 1" slope #8 up to 1/2" slope Please refer to Polyglass Roofing System TGFU.R14571 UL Listing for all fire rated systems *Available to Polyglass Approved Registered Contractors only. POLYGLASS WARRANTIES 10 & 12 Year LIMITED ROOFING MATERIAL WARRANTY - Prorated Material Only Warranty - available to all contractors. 10, 12, 15, & 20 Year MATERIAL & LABOR WARRANTY - Non - Prorated Material & Labor Warranty - available to Polyglass Approved Registered Contractors only. 10, 12, 15, & 20 Year ROOFING SYSTEM WARRANTY Non - Prorated NDL System Warranty (includes workmanship) - available to Polyglass Approved Registered Contractors only - all primary and secondary materials utilized within system must be supplied by Polyglass - warranty fees required. ROOFING SYSTEM WARRANTY FEE SCHEDULE 10 - Year @ $6.00 /sq or $600 minimum 12 - Year @ $8.00 /sq or $800 minimum 15 - Year @ $12.00 /sq or $1,200 minimum 20 - Year @ $15.00 /sq or $1,500 minimum Warranty requires the original installation of the roofing membrane must be installed in strict compliance with Polyglass current published specifications. Please see actual Warranty for Terms and Conditions. Polyglass does not practice Engineering or Architecture, neither the issuance of the warranty nor any review of the project documents, building, or other construction conditions by Polyglass Representatives shall constitute any acceptance or implied warranty by Polyglass of such plans, specifications, and construction or in any way constitute an extension of the terms and conditions of the Polyglass Warranty. Any roof inspections are solely for the benefit of Polyglass. MIOR POLYGLASS ROOF SYSTEMS UL Class A With Insulation and /or Coverboard Polyglass has a wide variety of UL fire rated systems with insulation and /or coverboards in the assembly. Please contact your local Polyglass Representative for specific needs. Mike Griffin - Polyglass Regional Manager 253 389 8099 mgriffin(apolyglass.com Steve Bogner (Region Technical Representative) 916 505 3807 sbogner @polyglass.com Tony Massa (Polyglass Technical Service Administrator) 800 - 894 -4563 ext. 243 tmassa@polyglass.com Rod Pierce Polyglass DSM 503 830 3661 Rpierce @polyglass.com Polyglass does not practice Engineering or Architecture, neither the issuance of the warranty nor any review of the project documents, building, or other construction conditions by Polyglass Representatives shall constitute any acceptance or implied warranty by Polyglass of such plans, specifications, and construction or in any way constitute an extension of the terms and conditions of the Polyglass Warranty. Any roof inspections are solely for the benefit of Polyglass. WAiLE. ewe A>O Iz1lUflVC Rs POLY6LASS Q�) ACCEPTABLE TORCH / SELF - ADHERING SUBSTRATES TORCH SELF - ADHERED G2 Base Sheet (also refered to as 281b base sheet) Polyisocyanurate (felt faced) Type IV and Type VI Ply Sheet Asphalt impregnated, six sided woodfiber board POLYGLASS Modibase Primed Structural Concrete POLYGLASS Elastobase Poly /Sand Primed, Metal or Metallic surfaces (Aluminum coating) POLYGLASS Elastoflex SA V DensDeck Prime (must be field primed) POLYGLASS ElastofleX S6, 2 and 3 mil Smooth DensDeck DuraGuard POLYGLASS Base (APP) USG Securock Primed Structural Concrete Hal's Asphalt Recovery Board USG Securock POLYGLASS Elastobase Poly /Sand GP Duraguard or Primed Densdeck (must be field primed) POLYGLASS Elastoflex SA V Celotex Structodeck TD New Plywood Decking (non- treated), or Primed Existing Plywood (non- treated). Joints must be taped. (When in doubt, prime) Hal's Asphalt Recovery Board EPS - supplied by Premier Industries only (refer to UL Approvals. Boards are - Insulfoam EPS, Type I, VIII, II, IX, or R- Guard: 2" and 2 lb density or greater). Please note: When applying to EPS in severe warm weather (90 degrees plus), Polyglass requires same day application of the Adeso components. (Same day application of Elastoflex SA V and Elastoflex SA P or Polyflex SA P). ASTM D -226 30# Felts, if properly attached. Typical pattern - 9" oc in seams, 2 -rows staggered in field at 12" oc. Consult Technical Support for varying substrates. NOTE: All surfaces to which membranes are to be applied must be clean, dry, free of dust or other debris. For Plank and Tongue & Groove installations, an approved mechanically attached base sheet is required. Asphalt primer must be Polyglass PG 100 ASTM D -41 Asphalt Primer, or approved equal ASTM D -41 Asphalt Primer. Water Based Acrylic Primer can be used for many priming circumstances and is preferred on vertical priming conditions. Polyglass WB3000 Adhesives & Sealants must be Polyglass POLYPLUS 50 (SBS Asphalt Adhesive /Sealant) or approved equal SBS Premium Modified Trowel Grade Asphalt Adhesive. Polyglass does not practice Engineering or Architecture, neither the issuance of the warranty nor any review of the project documents, building, or other construction conditions by Polyglass Representatives shall constitute any acceptance or implied warranty by Polyglass of such plans, specifications, and construction or in any way constitute an extension of the terms and conditions of the Polyglass Warranty. Any roof inspections are solely for the benefit of Polyglass. WATCLtOOPINO YAR➢IALS ANO I SL'LAIlNC l!T[Y! POLYGLASS' L POLYGLASS COATING SYSTEMS & WARRANTIES SUBSTRATE DESCRIPTION FOUNDATION FABRIC (optional) SATURANT BASE TOP WARRANTY NOTES Asphalt APP Mod Bit Smooth Emulsion Polyester Emulsion White White 7yr. or 10yr. 1 Asphalt SBS Mod Bit Smooth Emulsion Polyester Emulsion White White 7yr. or 10yr. 1 Asphalt BUR Smooth Emulsion Polyester Emulsion White White 7yr. or 10yr. 1 Asphalt APP Mod Bit Granulated Emulsion Polyester Emulsion White White 7yr. or 10yr. Asphalt SBS Mod Bit Granulated Emulsion Polyester Emulsion White White 7yr. or 10yr. Asphalt BUR Granulated Emulsion Polyester Emulsion White White 7yr. or 10yr. Single -Ply EPDM Membrane White Polyester - White White 7yr. or 10yr. 2 Single -Ply TPO Membrane White Polyester - White White 7yr. or 10yr. Single -Ply Metal White Polyester - White White 7yr. or 10yr. Metal Metal - - - White White 7yr. or 10yr. 3,4 Other Plywood White Polyester - White White 7yr. or 10yr. 5 Other Structural Concrete White Polyester - White White 7yr. or 10yr. Other Lightweight Concrete White Polyester - White White 7yr. or 10yr. 6 GENERAL Products Emulsion - PG800 Non - Fibered Asphalt Emulsion White - PolyBrite 70, PG 700, or EC 7000 White Elastomeric Roof Coatings PolyBrite 76 Base Coat for Ponding Water may be used for Foundation or Base Coat in lieu of White Application Rates* Emulsion - 2 -4 gal /sq. for Mod -bit systems or 4 -8 gal /sq. for gravel systems White - 1 -1.5 gal /sq per coat. 2 coats White required when applying over PolyBrite 76 Base Coat for Ponding Water Warranty ** 10 yr. with PolyBrite 70 White Elastomeric Roof Coating or 7 yr. with PG700 White Reflective Roof Coating $7.00 /sq. for Material and Labor Warranty NOTES 1. White may be used in lieu of Emulsion, depending on results of substrate inspection. 2. EPDM resurfacing agent may be used, but is not required. 3. Apply PolyBrite 72 White Flashing Compound to bolt heads and metal seams prior to applying Base Coat. 4. Application of 6 in. wide strip of Fabric embedded in 1 coat Polybrite 72 at boltheads and metal seams prior to applying Base Coat may be required, depending on reults of substrate inspection. 5. Apply 6 in. wide strip of Fabric embedded in 1 coat Polybrite 72 White Flashing Compound at wood joints prior to applying Base Coat. 6. Application of additional Top Coat may be required, depending on results of substrate inspection. 7. Only PolyBrite76 Base Coat for Ponding Water may be used as Foundation Coat over Urethane Foam Substrate. *Please see individual Product Data Sheets for Application Rates and Methods. ** Please see actual Roof Coating Warranty for Terms and Conditions. • PLANpK COPY • /ROUTING SLIP ACTIVITY NUMBER: D12 -245 DATE: 07 -27 -12 PROJECT NAME: SUNWOOD CARPORTS - REROOF SITE ADDRESS: 15235 SUNWOOD BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �C, Building Division Public Works ❑ iton /Mc 9-)---14 Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-31-12 Complete Ly] Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route 1 Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions y Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 08 -28 -12 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc. Date: 0 I% /1 'Z Plan Check/Permit Number: / / ❑ Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: SUP bim e J 0'10b �- "�� /��� %✓� % koor Project Address: (5-2- 3.5 50A)0 P.96 ob 8, Obi ro �W Contact Person:_77tL ( 4.94 Phone Number: 1(25 -7gd -0100 Summary of Revision: 41 HESS %D 1571`{l 5U4)1,000 c --4I l u /ZU3 /2-4 p K/N6 VeTS 22 —27 15775 soJJi,od &l eLd) (lJ/t 1,9 (70.Ki 0c5/2s7j RECENEd CITY OF TUKWILA AUG 0 9 2012 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Cent r by: Entered in Permits Plus on •'FE MArr (:ENTER H:\Applications\Eomu- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople kilter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company CONSOLIDATED GTR Ft SHT MTL LLC 2063009138 16751 Burke Ave North Shoreline WA 98133 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 603054384 Active CONSOGS902RN Construction Contractor 12/15/2010 12/15/2012 General Unused enses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NORTHCG964QQNORTHWEST CUSTOM GUTTERS Construction Contractor Metal Fabrication Unused 11/18/2004 2/5/2011 Expired Business Owner Information Name Role Effective Date Expiration Date KEENE, BRIAN A Agent 12/15/2010 Amount KEENE, BRIAN A Partner /Member 12/15/2010 FMWA00193902 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 UNITED STATES FIRE INSURANCE COMPANY 615978760 11/29/2010 Until Cancelled $12,000.00 12/15/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 First Mercury Ins Co FMWA00193902 12/01/2011 12/01/2012 $1,000,000.00 12/05/2011 2 First Mercury Ins Co FMWA00193902 12/02/2011 12/02/2012 $1,000,000.00 11 /30/2011 1 FIRST MERCURY INS CO FMWA001939 12/01/2010 12/01/2011 $1,000,000.00 12/15/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/08/2012