HomeMy WebLinkAboutPermit D12-268 - PDS TECH INC - TENANT IMPROVEMENTPDS TECH INC
12720 GATEWAY DR
SUITE 101
D12 -268
City okukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 2716000070
Address: 12720 GATEWAY DR TUKW
Suite No:
Project Name: PDS TECH INC
DEVELOPMENT PERMIT
Permit Number: D12 -268
Issue Date: 10/02/2012
Permit Expires On: 03/31/2013
Owner:
Name: EPROPERTY TAX INC DEPT #207
Address: PO BOX 4900 , SCOTTSDALE AZ 85261
Contact Person:
Name: DAVID KEHLE
Address: 1916 BONAIR DR SW , SEATTLE WA 98116
Contractor:
Name: DAVIS SCHUELLER INC.
Address: 20700 44 AV W STE 280 , LYNNWOOD WA 98036
Contractor License No: DAVISSI105PN
Lender:
Name:
Address:
Phone: 206 433 -8997
Phone: 206 775 -9400
Expiration Date: 07/01/2014
DESCRIPTION OF WORK:
REMOVE NON - BEARING WALLS (FORMERLY 1TT) AND CONSTRUCT NEW NON - BEARING WALLS, NEW DOORS, REMOVE
PORTION OF CEILING AND EXTEND EXISTING GRID AND TILES TO MATCH EXISTING, AND RELOCATE LIGHTS.
MODIFY HVAC, ELECTRICAL, AND SPRINKLLRS THROUGH SEPARATE PERMITS.
Value of Construction: $53,000.00 Fees Collected: $1,635.20
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: 11113 Occupancy per IBC: 0008
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D12 -268 Printed: 10 -02 -2012
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Size (Inches): 0
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
114,4.4.4g Date: / O z / Z
S4ricg6il
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
doc: IBC -7/10
012-268 Printed: 10 -02 -2012
7: Truss shop drawings shall be provided
e shipment of trusses delivered to the job Truss shop drawings shall
bear the seal and signature of a Washington Professional Engineer. Shop drawings sh maintained on the site
and available to the building inspector for inspection purposes.
8: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread
index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed
spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply
to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or
floor finish.
9: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the
recommendations given in the soils report. Special inspection is required.
10: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
15: ** *FIRE DEPARTMENT CONDITIONS * **
16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
doc: IBC -7/10
D12-268 Printed: 10 -02 -2012
1008.1.8.1)
25: Exit hardware and marking shall meet th requirements of the International Fire Code. Chapter 10)
26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mrn). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (WC 1011.5.1)
28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1
foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor
level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point
of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination
uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4)
30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinlder heads. (IFC 901.4)
32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance No. 2327).
34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2328)
35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC
104.2)
36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
39: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite,
room or apartment number in a conspicuous place near the main entry door. (IFC 505.1)
40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and
#2328)
41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IBC -7/10
D12 -268 Printed: 10 -02 -2012
CITY OF TUK.A
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www.TukwilaWA.gov
Building Plait No.
Project No.
Date Application Accepted:
Date Application Expires:
0�11�L��3
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: I VI 2,0 0 W r
Tenant Name: Ft2(1 -r t 1 m
King Co Assessor's Tax No.: 2 7 (ID%t) -00"C"10--01.0
Suite Number: 101 Floor: 1
New Tenant: 0 Yes ❑..No
PROPERTY OWNER
Name: Goe
Address , /f; , 10+16 lel Phi, CAit 24
City: K- State\ Zip:
CONTACT PERSON — person receiving all project
communication
Name: t2#) Ocati t
Address:
Address: viIv yb141Q .pz e',.1
1NL
1,/ �
City: int State
.
Zip: tuili la
Phone:/00,4 4q ax 744,
1
Email: abhle edkedhle av'G \. Com
Phone:
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
Company Name:W O 6'N
1,/ �
City:
State:
Zip:
Phone:
Fax:
City0 State: 0
Contr Reg No.:
Phone:e _4? ?� bq A 4. Fax -
Exp Date:
_ t
1
Tukwila Business License No.:
1
Fax:
H:\Applications \Forms - Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
ARCHITECT OF RECORD
%
Name: air "{ O
Address:
Company Name:W O 6'N
1,/ �
Architect Name: chlo ktig
Engineer Name:
Address: viNY'e
Address:
City0 State: 0
Z1pu`( 0
Phone:e _4? ?� bq A 4. Fax -
_ t
1
Email: a het* e d �ie4,01.
1
ENGINEER OF RECORD
%
Name: air "{ O
Address:
Company Name:
1,/ �
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
%
Name: air "{ O
Address:
City: State: Zip:
Page 1 of 4
I „v1.1.∎1' ivv rrdsaviiI livt'UHivIA1ION —206- 431 -3670
Valuation of Project (contractor's bid pr : $ '? 3 OOD Existinggilding Valuation: $ ')X7
Describe the scope of work (please provide detailed information): a=t=tiNE E((StK .1 I1o14- e lL -, CfrxmevAir
119j boo a,tstituvt' Lim I - ell e-1414 I uh ,v Q252( --7 (WAtiti
440 rtroo Fyastlui too bD ti s ~6 Iqt tt Lac �s -rt�c, Utlrty7, hoop HV
�ro
elotituta, qv-1am ( - Reorsi*)
Will there be new rack storage? ❑ .... Yes
..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
l” Floor
Existing
Interior Remodel
Addition to
Existing
Structure
New
2nd Floor
3rd Floor
039
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
Type of
Construction per
IBC
Type of
Occupancy per
IBC
x=111'5
111 -13
..3
g
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: 14.) &1414E4'7 Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers 12i Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes A No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:IApplicationsWorms- Applications On Line\2012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
Page 2 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE
Signature:
Print Name: poi 0 (,1`
ED AGENT:
Mailing Address: V1 ka 4/W
H:tApplicationsWonns- Applications On Line12012 Applications\Permit Application Revised - 2- 7- 12.docx
Revised: February 2012
bh
Date: b 1 14 \
Day Telephone:"i �v 3 -?C'
I
City
State Zip
Page 4 of 4
Parcel No.:
Address:
Suite No:
Applicant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
2716000070
12720 GATEWAY DR TUKW
PDS TECH INC
RECEIPT
Permit Number:
Status:
Applied Date:
Issue Date:
D12-268
ISSUED
08/14/2012
10/02/2012
Receipt No.: R12 -02851
Initials:
User ID:
WER
1655
Payment Amount: $63.00
Payment Date: 10/12/2012 01:41 PM
Balance: $0.00
Payee:
GARY MYERS
TRANSACTION LIST:
Type Method Descriptio
Amount
Payment Credit Crd MC
Authorization No. 01353Z
ACCOUNT ITEM LIST:
Description
63.00
Account Code
Current Pmts
PLAN CHECK - NONRES
000.345.830
Total: $63.00
63.00
doc: Receipt -06 Printed: 10 -12 -2012
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 2716000070
Address: 12720 GATEWAY DR TUKW
Suite No:
Applicant: PDS TECH INC
RECEIPT
Permit Number: D12-268
Status: APPROVED
Applied Date: 08/14/2012
Issue Date:
Receipt No.: R12 -02745
Payment Amount: $992.80
Initials: LAW Payment Date: 10/02/2012 10:05 AM
User ID: 1632 Balance: $0.00
Payee: DAVIS SCHUELLER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 069291 992.80
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 988.30
640.237.114 4.50
Total: $992.80
doc: Receiot -06 Printed: 10 -02 -2012
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 2716000070
Address: 12720 GATEWAY DR TUKW
Suite No:
Applicant: PDS TECH, INC.
RECEIPT
Permit Number: D12 -268
Status: PENDING
Applied Date: 08/14/2012
Issue Date:
Receipt No.: R12 -02355
Payment Amount: $642.40
Initials: JEM Payment Date: 08/14/2012 02:50 PM
User ID: 1165 Balance: $992.80
Payee: DAVID E KEHLE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 04597C
ACCOUNT ITEM LIST:
Description
642.40
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 642.40
Total: $642.40
doc: Receipt-06 Printed: 08 -14 -2012
INSPECTION RECORD
Retain a copy with permit
INSPE TION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
D12 -2 Lb
Project:
PDS'a aki
Type of Inspection:
totoAL
0Or ,/ el )•j <^Cif 4p,) /e-AJ /
Address:
I 2-71 2.-0 CHAT E1u-% Acl 0t
Date Called:
Special Instructions:
Date Wanted:
r
a.n .
-
Requester:
Phone No:
Doti- Diu -C/G6y
IAApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Pre-, e7 ) •7 1 /e1 t p t g. /t. " //:-.1.1./P1 /
0Or ,/ el )•j <^Cif 4p,) /e-AJ /
■
R NSPECTION FEE REQUIRED. Prior to next inspection. fee must be
aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
4
INSPECTION RECORD
Retain a copy with permit .C) /2 -266
INSPECTIO O. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION •
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)'431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
/ " I , D _ S 7"7' ..ZAr
Type of Inspection: •
e' /7-1 F/2C0 - / L/ 6 67ii/ i
Address:
/2 7,,24 Gqi
(4/r9 vk
Date Called:
Special Instructions:
Date Wanted: -
Requester:
Phone No:
,Z c' _ S'/4_ s Ga y
Approved per applicable codes. Corrections required prior to approval.
COM ENTS:
ecto?t
(644.-467
��x t
Date:
/// //7._
R I SPECTION FEE REQ IRED. Prior toinext inspection, fee must be .
oaid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
1/
INSPECTION RECORD
Retain a copy with permit .t t 2-2._ 43 j
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206). 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
P 0 C., 1 iti-4►
Type of Inspection:
c.--,i L<- ,P.C1..1t It ff 1..►&/v
Address:
1)'7/_(-) aA mow+}
t•,R
Date Called: .
Special Instructions:
Date Wanted:.
IC)-.30 - \2.
p.m.
Requester:
Phone No:
2 04.-.16 -c•tm:014
`R Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
r Date:
SPECTION FEE REQUIR D. Prior to ext inspection, fee must be
id at 6300 Southcenter Blvd!. Suite 10 Call to schedule reinspection.
tnspecto •
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
Project:pAs. -ry_ /_
Type of Inspection: C I +167
Address:
2`? Z0 CLAWKI
Date Called:
Special Instructions:
Date Wanted:O 2 -(-1._ air .
p.m.
Requester:
PhorT 6 r �i ®° g 4:70/
ElApproved per applicable codes.
COMMENTS:
Corrections required prior to approval.
e
(St t (t )Jee 5 Xe-ct. C..
6fr--- 67.7-ev I
n6
I ns pei tor:
0A-P
NFEE REQUIRE . Pr
Date:
❑ REINSPECTION Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
! i .
I
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43.1-3670 -
Permit Inspection Request Line (206) 431 -2451
Proj i s ' I• /�
?
TYpe Si of IsspectiCon:� 1 • C et'
Address: -
? . 7 ?.o 6v.
u/A
Date-Called:
L G -( Aka / C
Special Instructions:
Date Wanted:. a.
I p _ 2- G, — 12.. p.m.
Requester:
Phone No:
?�(o -Si 0449 O �/
ElApproved per applicable codes.
Corrections required prior to approval:
COMMENTS:
6) ''y r% ". s /- s�,-/r
-- i' 'f 7 A.4 /S - '' (All /e--
Jr?-'r-,.wr
/''S /3G '4 " /-% -" 4,4 M' sS/ /S Q✓Pr r/ddV c.,/, j
ns� pe to
Date:
)0- a'- /a. •
INSPECTION FEE REQU ED. Prior/to next inspection, fee•must be'
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection:
r
'
•
INSPECTION RECORD L
Retain a copy with permit-P-'
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION C.--
6300 Southcenter Blvd., #100, Tukwila. WA 98188 tr.. (206) 431-3670
Permit Inspection Request Line (206) 431-2451
proJecpo
_
1 e 4-4 rAr
Type of Inspection:
fer.A- AA :A Ce?
Address: 1
1/44Act
Date Called:
Special Instructions:
-
-ek C- fir://1
Date Wanted:. a.m.
10-15-11— 421--11-
Requester:
Phone No:
-2._ S - 7 (0 -1 6 oit
Approved per applicable codes. Corrections required prior to approval.
COMMENTS: ,
•
/A—
13L0 "VA ,1 L•Li/
-ek C- fir://1
t) ( -Li ta—A-K_ /10 kr
1—b r"
idu _s
a 6•LT
61-
.-----s. !+
Ins °LK_
Datei
I 0
F-7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
_ r". -••••••__ _
3
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
ia. -F - a33
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407
Project:
PISS -1-49L1-,
Type of Inspection:
5pkki f Fkv F' i
Address: /2) yu Gait,,. / b►-
Suite #: /0
Contact Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Y
Fire Alarm:
•
Hood & Duct:
S k Foha1 Olc
Monitor:
wA 4-14,-4-..
Pre -Fire:
A- f; 01<
t /
N
Occupancy Type:
A
o
w
Needs Shift Inspection: `/
Sprinklers:
Y
Fire Alarm:
Y
Hood & Duct:
''
Monitor:
wA 4-14,-4-..
Pre -Fire:
Permits:
N
Occupancy Type:
A
Inspector:
kty..‘73--1 )
Date: 1/- 7-I ).•
Hrs.:
i
n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
•
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
ti
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila; Wa. 98188 206 - 575 -4407
Project: °' ri
PD5 Test ..
Type of Inspection: .Inspection:
F Polo( `
1Addres: / ) . . 7 ) . . 0 CrcdrWG/ Dv S .
Suite #: Jo I
Contact Person:
C i's,e
Z-lci,.,.e....
Special Instructions:
Phone No.:
Occupancy Type:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
/ a} r, /S41,oLei 4'4; l e i -fib 4 cf.�d'e
Pre -Fire:
Permits:
Occupancy Type:
Prt -+-rs hbi-_dt
A - -pi- c -+fi+ Cff-+1
4
1
1 Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
1V
y I (
Date: /1-5 -/.
Hrs.:
$100.00 REINSPECTION FEE REQUIRED: You will receive an invoice from
t e City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn: 6`,4$4 Company Name: Lkkei4r -b. 5)--4 Fi ►-c els /cc
Address: ! II( ya N- t- 9.114, 5f. -_ /0 1
City: teed 4,eiid, Wic 590,-e
State: tv .A
Zip: 'ZoY --
Word /Inspecon Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
•
.
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
17/2 - eNtP
'a— s_Z-11
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407
•
Project: PD 5
re,
am/ /9 /� <.,r gs ..f/, .14,0 0...4.-,, ,s.1. s-. , •,' -C_..
7-.4c .
Date:
Type of Inspection:
.$CP.• Jc1...e �.._,
Address: / 2 7 2
Suite #: 1 .'1
'
42.
4.udY
+°'Q •
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
L.
fJe vi s ...,, s,�Lf L.
am/ /9 /� <.,r gs ..f/, .14,0 0...4.-,, ,s.1. s-. , •,' -C_..
0 Ode -f ,.., r ••40y,4.31 .
Date:
..
Hood & Duct:
Monitor:
•
•1
Pre -Fire:
Permits:
Needs Shift Inspection:
/
Sprinklers: •
Fire Alarm:
Date:
/OA-Sit 7-
Hood & Duct:
Monitor:
•
•1
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
/
,41s
3
Date:
/OA-Sit 7-
Hrs.:
/
$100.00 REINSPECTION FEE REQUIRED. You will rethive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
I Company Name:
Address:
City:
State:
Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
•
•
2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential
Initerior.Lighting Summary
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010
Date pi [I
For Building Department Use
LTG -IN.T
Project Info
Project Address
IZ12a 601847A4 Cla It3J
Applicant Name: �(0 Cite/ %111Te-(;r
Applicant Address: ill it, NA 12 t �/ai1tk, t,06. Fitiot
Applicant Phone: (o . c -53 .,.EAt1 1.-
FILE COPY
Project Description
New Building ❑ Addition Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
[] No changes are being made to the lighting and space use not changed
*Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor plan /room #)
Occupancy Description
Allowed
Watts per ft2**
Gross Interior
Area in ft2
Allowed x Area
** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
Proposed Lighting Wattage
Location
(floor plan /room #)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Propo
of Tukwila
INC DIVI5I
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track
multiplied by 50, or as applicable. the wattage of current limiting devices or of the transformer. For low voltage track lighting list the
transformer rated wattage.
3. List all fixtures. For exempt lighting, note section and exception number. and leave Watts /Fixture blank.
E
N
RECEIvEU
CITY OF TUKW L.A
AUG l it-2012
PERMIT CENTER
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
Enve;lope:.Summary
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential
Project Info
FILE COPY
ermq No.
Project Address art-t--w944, •��,1 I In �� i
O t 2 i rtr
l�
1441.2_,
Applicant Name: aw to ix
Xpplicant Address: h I to ry
e 94.
Applicant Phone: /CV ..433� -- 941-
Project Description
❑ New Building
❑ Addition (Alteration
Compliance Option
❑ Prescriptive (❑ Component Performance
(See Decision Flowchart (over) for qualifications)
Occupancy Group
0 Nonresidential 0 Multifamily Residential
Climate Zone
®' Climate Zone 1 0 Climate Zone 2 ( See
Fenestration Area Calculation
Total Fenestration Electronic version: these values are automati
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area
Roofs - Metal Building
Semi- Heated Path
O yes Allowable if project meets at requirements as defined In section 1310.2
no calculated separately from other conditioned spaces. Limited to reduce
el and •uali in. thermostat.
Envelope Requirements (enter values as applicable)
Minimum Insulation R- values
Roofs - Insulation Above Deck
Roofs - Metal Building
REVIEWED
FOR
2 8 2012
Tukwila
G DIVISION,
Roofs - Single Rafter
CODE COMPLIANCE
Roofs - Attic and All Others
APPROVED
Walls - Mass
Walls - Metal Building
SEP
Walls - Steel Framed
• —z—
Walls - Wood Framed and Other
Floors - Mass
City of
Floors - Steel Joist
BUILDII!
Floors - Wood Framed and Other
Maximum F- factors
Slabs -on -Grade - Unheated
Slabs -on -Grade - Heated
Notes:
Ik OiCU2 'Jitici
Envelope Requirements
Vertical Fenestration
Non -Metal Frame
Metal Frame
Entrance Door
Skylights - Without Curb
Skylights - With Curb
Opaque Doors - Swinging
Opaque Doors - Non -Swir
Vertical Fenestration
Non -North
North
Skylights
WSEt
ally t.
. Only
i wall i
REUrivtu
CITY OF TUKWILA
AUG 1_41 2012
PERMIT CENTER
Da.--210z
PPR
Lo, •
david
kehle
rch�
reit% r
September 19, 2012
City of Tukwila
Building Division
6300 Southcenter Blvd. Suite 100
Tukwila, Washington 98188
Attn: Mr. Dave Larsen
PDS Tech, Inc
Re: Permit #D12 -268
Dear Dave,
As we discussed over the phone today, I have added an exit door from the conference room to
isolate that conference from the rest of the space for exiting purposes. also I have calculated
the storage rooms separately the total between the two is under .5 occupants so have not
included that in the occupant load. The balance of the office occupant load is 48 so a single exit
is allowed. I have kept the other door (12) into the corridor for an employee entrance.
The pathway lighting goes away as well since it is a single exit system.
Sheets T -1 and T -3 were revised with flagging of rev 3. I have included two sets since you are
the only reviewer.
If you have any questions, please call.
David Kehle
DK/dk CORRECTION
Cc: Greg Coleman LTR#
8704- 7/citylet09 -19 -12
1916 Bonair Drive S.W.
Seattle, WA 98116
Q (z -z(0s
RECEIVED
CITY OF TUKWILA
SEP 2 0 2012
PERMIT CENTER
(206) 433 -8997
fax (206) 246 -8369
email: dkehle @dkehlearch.com
•
city of Tukwila
Jim Haggerton, Mayor
epartment of Community Development Jack Pace, Director
September 20, 2012
David Kehle
1916 Bonair Dr S
Seattle, WA 98116
RE: Correction Letter #2
Development Permit Application Number D12 -268
PDS Tech, Inc. —12720 Gateway Dr, Ste 101
Dear Mr. Kehle,
This letter is to inform you of corrections that must be addressed before your development permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building Department. At this time the
Fire, Planning, and Public Works Departments have no comments.
Building Department: Dave Larson at 206 431 -3678 if you have questions
regarding the attached comments.
Please address the attached comments in an itemized format with applicable revised plans, specifications,
and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or
other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, I can be reached at (206) 431 -3670.
Sincerely,
Jnnllfer Mars all
t Te'hni ian
encl
File No. D12 -268
W:\Permit Center \Correction Letters \2012\D 12 -268 Correction Letter #2.doc
6300 Southcenter Boulevard, Suite #100 o Tukwila, Washington 98188 . Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
!
Tukwila Building Division
Dave Larson, Senior Plan Examiner
Building Division Review Memo #2
Date: September 19, 2012
Project Name: PDS Tech Inc.
Permit # D12 -268
Plan Review: Dave Larson, Senior Plans Examiner
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and /or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed.
1. I called John Gonzalez with ICC to get an informal opinion on the exiting situation of this tenant
space proposal. His comments included the following;
• The proposal is creating a new tenant space and therefore needs to meet code
requirements.
• The corridor is part of the exit access and not the exit and therefore is included in the
exit access path of travel.
• The definition of common path of travel states that paths that merge are common paths
of travel and therefore this tenant proposal does not have two legitimate exits.
A revised exit plan is needed based on Mr. Gonzales comments and examples of similar
exiting problems.
Should there be questions concerning the above information please contact the Building Division at 206-
431 -3670.
•7
david e
architect
September 6, 2012
City of Tukwila
Building Division
6300 Southcenter Blvd. Suite 100
Tukwila, Washington 98188
Attn: Mr. Dave Larsen
PDS Tech, Inc
Re: Permit #D12 -268
Dear Dave,
RECEIVED
CITY OF TUKWILA
CORRECTION SEP 1 0 2012
LTR# PERMIT CENTER
I am in receipt of your comment letter dated August 24th, sent August 28th. I have added the
occupant load of the large spaces on the exit pathway plan on sheet T -3 and lumped the other
office areas for sake of clarity. I am sure you did not mean each office needed an occupant
load. The total occupant load is 72 requiring two exits.
The two exits are 1/3 of the max. diagonal distance to comply with 1015.2.1.2. There is a
common path of travel to get to the pathway within the space which is allowed and is under the
100 If code limitation of 1014.3.1.
As to the points of exit into the 1 hour corridor system existing in the space, there is nothing in
the code preventing these two exit discharge points from entering the same exit corridor. And in
fact, every high rise has the same types of conditions where an exit corridor is accessed by the
same tenant even with multiple exits required from their space. It is no different in this building
where a mid corridor tenant requiring two exits can exit into the same corridor. That is what the
corridor exiting system is all about.
In the commentary page 10 -107 there is an illustration similar to our condition where multiple
exits enter a rated corridor. Also in the commentary regarding Section 1015, top right comment
(pg 10 -107), This refers to minimum number of paths of travel an occupant is to have available
to avoid fire in the occupied room or space. The existing system is for the individual space
and does not apply to the corridor. Another example of two exits into a corridor is found on
page 10 -11. In figure 1015.2.1 (4), describes a space requiring two exits in a corner office into
a corridor. It is not acceptable because of the diagonal distance apart for the exits, but would be
allowed if the doors into the corridor were of proper separation. Same is my condition.
1916 Bonair Drive S.W.
Seattle, WA 98116
b12-11,0
(206) 433 -8997
fax (206) 246 -8369
B l: dkehle @dkehlearch,com
• •
Another example of the corridor logic, would be if you are worried about a potential fire in the
corridor blocking the exit doors, that would then be true of all tenants off a corridor, single exit or
not. That is just not the way the code reads.
I cannot agree with your interpretation on your item 2 of the plan review. My plan does comply
with the code and should be approved.
By the way, the existing space was ITT and had an exit into the main building exit corridor as
well as another exit door into the ITT interior corridor. There is no exterior direct egress from
this space.
If you have any questions, please call.
Sincere
,
David Kehle
DK/dk
Cc:
Greg Coleman
8704-7/citylet6-25-07
S
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
August 28, 2012
David Kehle
1916 Bonair Dr S
Seattle, WA 98116
RE: Correction Letter #1
Development Permit Application Number D12 -268.
PDS Tech, Inc. —12720 Gateway Dr, Ste 101
Dear Mr. Kehle,
This letter is to inform you of corrections that must be addressed before your development permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building Department. At this time the
Fire, Planning, and Public Works Departments have no comments.
Building Department: Dave Larson at 206 431 -3678 if you have questions
regarding the attached comments.
Please address the attached comments in an itemized format with applicable revised plans, specifications,
and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or
other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, I can be reached at (206) 431 -3670.
encl
File No. D12 -268
W:\Permit Center\Correction Letters\2012\D12 -268 Correction Letter #l.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
•
Tukwila Building Division
Dave Larson, Senior Plan Examiner
Building Division Review Memo
Date: August 24, 2012
Project Name: PDS Tech, Inc.
Permit # D12 -268
Plan Review: Dave Larson, Senior Plans Examiner
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and/or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed.
1. Please provide the total occupant load for this area and show the occupant load of each room on
the floor plan.
2. The egress plan shows an illuminated egress path that leads to two exits. See the definition of
common path of travel below. The exits provided generally lead in the same direction and are not
distinct and eventually converge in the same spot while still inside the building. This area had
access to the west exterior exit and this plan will eliminate this access. Please revise the egress
system to meet the intent of the code.
COMMON PATH OF EGRESS TRAVEL. That portion of exit access which the occupants are required
to traverse before two separate and distinct paths of egress travel to two exits are available. Paths that
merge are common paths of travel. Common paths of egress travel shall be included within the permitted
travel distance.
Should there be questions concerning the above information please contact the Building Division at 206-
431 -3670.
PLAN PER1 W /ROfNG SLIP
ACTIVITY NUMBER: D12 -268 DATE: 10 -03 -12
PROJECT NAME: PDS TECH INC
SITE ADDRESS: 12720 GATEWAY DR
Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # X Revision # 'I After Permit Issued
DEPARTMENTS:
Building ivision
N //�- L-'
0
4L4
re Prevention
Planning Division
Public Works ❑ Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -04 -12
Complete
Incomplete
Not Applicable
Comments:
Permit Center Use Only .
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S IN TIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 11 -01 -12
Approved 1W Approved with Conditions ❑ Not Approved (attach comments) ri
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
PE' : CO CO.PY•
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -268 DATE: 09 -20 -12
PROJECT NAME: PDS TECH INC
SITE ADDRESS: 12720 GATEWAY DR - SUITE 101
Original Plan Submittal Response to Incomplete Letter #
X Response to Correction Letter # 2
Revision # After Permit Issued
DEPARTMENTS:
g q 7 I I�
Public Works n
Fire Prevention
Structural
n
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
,Li
Incomplete
DUE DATE: 09-25-12
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route V Structural Review Required ❑ No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 10-23 -12
Approved ❑ Approved with Conditions / Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
DC D C S Ye
PLA VIEW /ROUTING SLIP
ACTIVITY NUMBER: D12-268 DATE: 09 -10 -12
PROJECT NAME: PDS TECH INC
SITE ADDRESS: 12720 GATEWAY DR, SUITE 101
Original Plan Submittal
X Response to Correction Letter # 1
Response to Incomplete Letter #
Revision # After Permit Issued
DEP THE k TS:
Pt- 4
uilding Division
Fire Prevention
Planning Division
Public Works ❑ Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 09 -11 -12
Not Applicable
Comments:
Permit Center Use Only ' y .. ` •
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route 13] Structural Review Required u No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 10 -09 -12
Approved n Approved with Conditions ❑ Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Ceriter:Use'Orily. • •':f
CORRECTION LETTER MAILED: v+ Z
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
•
� PERMIT COORD C0R
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D12 -268 DATE: 08/14/12
PROJECT NAME: PDS TECH, INC
SITE ADDRESS: 12720 GATEWAY DR, STE 101
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter
Revision # after Permit Issued
DEPIvART ENTS ! .1 se2A. `� A-W A A' 9-A14-42,
Fire Prevention B�iilZffn Ivision i. Prev/
g � ❑ Planning Division
�� � (iA (1-2-
PuT�lic Work
Structural
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete ❑
DUE DATE: 08/16/12
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Ni Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 09/13/12
Approved ❑ Approved with Conditions I I Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit •Center Use Only • •
CORRECTION LETTER MAILED: (46
Departments issued corrections: Bldg
Fire ❑ Ping ❑ PW ❑ Staff Initials:
PROJECT NAME: P • T-PCL PERMIT NO: • I �- 024 8
SITE ADDRESS: D---7)- D Coq 4.4.414 y e- ID ( ORIGINAL ISSUE DATE: 10
REVISION LOG
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIA S
l0 -3 Ia-
to- ()--L-
Summary of Revision: 0-GC cf k, (( lei pv� ckA by P�
Summary of Revision:
Received by: 6A724/ Myers 10 -12 -Iz
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
i
• •
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Steve Lancaster, Director
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: if)
Plan Check/Permit Number: V -7,4 6
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
RI Revision # I after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: I' w/ �4� 1'1 I i46/
Project Address: 1Z72,0 alll( t;V. ,�,,
Contact Person: 1■P k i
Phone Number: fk 453M41--
Summary of Revision:
t -1 i itulro Gnu, 13t110EW DNu 4 °I / affeE
Paet5 tUb i I 'iu0A) a but) rote 7,
bao tjt►a24,16 .1 (O ttau
Sheet Number(s):
"Cloud" or highlight all areas of revision including ate o
Received at the City of Tukwila Permit Center by:
cliir-Entered in Permits Plus on
RIVED
CI1v OF TUKWILA
OCT 03 20121
ENTER
lapplicationslforms- applications on linelrevision submittal
Created: 8 -13 -2004
Revised:
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
Plan Check/Permit Number: D12-268
❑ Response to Incomplete Letter #
® Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: PDS Tech, Inc.
Project Address 12720 Gateway Dr, Ste 101
Contact Person: )604E, Phone Number: lere 3-hill
Summary f Revision:
RECEIVED
AERMIT CENTER
Sheet Number(s).
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: ---k)->
'Entered in Permits Plus on q40—
\applications\forms-applications on line\revision submittal
p.
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwilawa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: reillP bl— Plan Check/Permit Number: D12-268
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: PDS Tech, Inc.
Project Address: 12720 Gateway Dr, Ste 101
Contact Person: 1,0 NU- Phone Number:710 '3 44 T
Summary of Revision:
RECSVED
0121
PERMIT CENTEp
Sheet Number(s): W
I
"Cloud" or highlight all areas of revision Including date of rev
Received at the City of Tukwila Permit Center by:
k-- Entered in Permits Plus on 9,-( U') Z
\applications\forms- applications on Iinekevision submittal
Created: 8 -13 -2004
Revised:
Contractors or Tradespeople P ter Friendly Page
•
Page 1 of 2
General /Specialty Contractor
A business registered as a construction contractor with LItI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name DAVIS SCHUELLER INC UBI No. 601273797
Phone 4257759400 Status Active
Address 20700 44Th Ave W Ste 280 License No. DAVISSI105PN
Suite /Apt. License Type Construction Contractor
City Lynnwood Effective Date 10/15/1990
State WA Expiration Date 7/1 /2014
Zip 98036 Suspend Date
County Snohomish Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty 2
Effective
Date
Expiration
Date
Status
RSMANI "011BN
MANUFACTURING
INC
Construction
Contractor
Cabinets,
And Millwork
Finish
Carpentry
Unused
1/15/1999
3/3/2013
Active
SILVECI988Q0
SILVERCREEK
CONSTRUCTION
INC
Construction
Contractor
General
Unused
11/20/2002
11 /20/2004
Archived
SEACRMI104DE
SEACREST MFG
INC
Construction
Contractor
Cabinet
And
Millwork
Carpentry/Framing
3/5/1990
2/26/1999
Archived
OLYMPE "121 Qp
OLYMPIC
ENTERPRISES
Construction
Contractor
General
Unused
11/1/1988
11/1/1989
Archived
DALFOCI1810E
DALFORD
COMPANY INC,
THE
Construction
Contractor
General
Unused
2/5/1982
12/26/1991
Archived
DALFOC *198LW
DALFORD
COMPANY, THE
Construction
Contractor
General
Unused
6/16/1981
6/1/1982
Archived
DAKOTWC962BH
DAKOTA
WIRELESS CONST
SVCS LLC
Construction
Contractor
General
Unused
1 /8/2004
1 /8/2006
Out Of
Business
Business Owner Information
Name
Role
Effective Date
Expiration Date
DAVIS, BILL E
President
01/15/1990
https: // fortress .wa.gov /lni/bbip/Print.aspx
10/02/2012
DEMO NOTES:
1. (REMOVE ALL WALLS AND DOORS AS SHOWN. SAVE DOORS TO BE
REUSED IF POSSIBLE.
2. PATCH AND REPAIR ALL WALL, FLOOR, AND CEILING
3. REMOVE FINISHES AS REQUIRED
4. CAP ANY PLUMBING AND NOTE ON A5 BUILT DRAWING
5. REMOVE ANY ELECTRICAL NOT USED TO ABOVE CEILING, TO NEW
J -BOX WITH NOTE ON PANEL AND CIRCUIT NUMBER LISTED.
5. RELOCATE HVAC AS REQUIRED FOR DEMO AND NEW WORK. SEPARATE
FROM ITT SYSTEM
poo SCHEDULE EX 151-11s4G:
El EX. 3'X-1' SOLID CORE 20 MIN. DOOR AND WOOD FRAME, LOCKSET
(INSIDE LEVER TURNS FREE FOR EXIT).
DOOR SCHEDULE NEUY.4\
NEW OR REUSED DOORS WITH NEW LEVER HANDLES, MATCH EXISTING
2 -4 3' -0" X 1' -0" S.C. WOOD (STAINED) WITH WOOD JAMBS,
6,8,9 LOCKSET (LEVER), 1 1/2 PAIR BUTTS, SILENCER, WALL STOP
1 3' -0" X 1' -0" S.C. WOO (STAINED), WOOD JAM, LATC4SET, I
1,10 1/2 PAIR SUTTS, SILENCERS, WALL STOP
12,13 3'- 0 "X1' -0" S.C. WOOD (STAINED), WOOD JAMS, LOCKSET,1 1/2 PARI
E`'UTTS, SMOKE GASKETS, WALL STOP (20 MN RATED DOOR)
3' -0 "X 1' -0" WOOD CASED OPENING
ROOM SCHEDULE:
1 -(o FLOOR: NEW CARPET
9,10 SASE: NEW BASE
WALLS: EX. TO 5E REPAINTED (EE)
NEW WALLS PAINT (EE)
CEILING: EX. SUSP.ACOUSTIC MODIFY AS REQUIRED
1,8 FLOOR: NEW VCT
12 BASE: NEW RUBBER BASE
WALLS: NEW GYP BD PAINT (REPAINT EXISTING)
CEILING: EX. SUSP ACOUSTIC
Pt_ -r-.
WINOW SCHEDULE:
L
A NEW 2' -0" X 6' -6" WITH SILL AT +6 ", CLEAR 1/4" POLISH PLATE SAFETY
GLASS IN WOOD FRAME ( MATHC DOORS)
WALL TYPES:
A. NEW NON BEARING INTERIOR PARTITION: 3 5/8" X 25 GA STEEL STUD
AT 24" O.C. TO CEILING ABOVE (SI IS SOUND INSULATED).W/ 5/8" GYP BD
EACH SIDE.
S. IN FILL WALL: MATCH EXISTING STUD WALL FOR THICKNESS OF STUD
AND TYPE OF STUD, 5/8" GYP 130 EACH SIDE (MATCH EXISTING).
C. NEW 1 HOUR RATED WALL TO MATCH EXISTING (WPI200), 5/8" TYPE 'X'
GYP SD EACH SIDE TO 1 HOUR CEILING (SEE CROSS SECTION)
i
!SEPARATE ►TE PERMIT
rZOUIRED FOR
lialt ei hanicat
iectrht
Celumtirp
gleas NOV
Cij of Tukwila
`31.i I_p6 IG DIVISION
REVISIONS
P'-► r. r Des shall be, made to the scop
c,a ' ,i+ho:!t prior approval of
r3, _ i ng Division.
d ! r7quire a new plan subm tal
add: ienai plan review faes.
7..oz • n, b s Fb•e,,} morn s".711 n 'iis7,77 s.
- c7,,td i+6Jf,:ai �.' L.fi4• `:' aw:
Jf:
and coriciitons
Gy
Y Tu!3
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 9 2012
City of Tukwila
BUILDING DIVISION
POWER POLE OR FURNITURE WHIP VERIFY
WIN TENANT. ALLOW FOR 3 CIRCUITS
(CLEAN, 2 DIRTY) PER POWER POLE SERVING
UP TO 3 WORKSTATIONS
STANDARD DUPLEX OUTLET AT STANDARD
HEIGHT. VERIFY LOCATION WITH TENANT
MUD RING WITH PULL STRING FOR P'4
Q DATA (PHONE AND DATA 5Y TENANT)
POWER AND PHONE/DATA LOCATIONS SHOWN ARE
PREFERED LOCATIOS, HOWEVER IF THERE ARE
EXISTING OUTLETS CLOSE 5Y, THEN VERIFY' WITH THE
TENANT IF THE EXISTING WILL WORK.
N E:
SEE SHEET T -3 FOR EXIT DISTANCES AND EXIT
PATHWAY LIGHTING
SEE T -3 FOR WALL AND DOOR DETAILS
SEE T -3 FOR CORRIDOR SECTION
I I
r
EX, STA-F-
EX, LAB 3
REMOkJ'E EXISTING WALLS
AND [ORS AS SHOILN
II \ II
61_1 - -- — _-\ -rr
9
'4t, FIRST FLOQR OFFICE: DEMO
SCALE: I/8" = 1'4
IL
EX, THEORY 2 I" �`,
EX, HALLS
IT .N
tr
EX, TH
EORY 3
MEN
0
o L
0
OQ
op
00
on
00
O
O
no WOMEN
00
100' -6
WOMEN
O
0
O
OF.
00
oC
no
MEN
0
O
STORAGE
AREA OF CIVE SACK = 5,331 SF
12 -02 -11
08 -10 -12
co
a
W
0
c
8
w
oc
0
ct
u
r•V
tc
0
41)
G)
CONFERENCE
COPIER,PLOTIAX
•
I
Cu
EX. ELEC.
EXT. 1 HOUR
HALL
EX. HALL
RECEIVED
CITY OF TUK ^ILA
X. ITT
MEN
EX. ITT
WOMEN
EX.
COMMON
WOMEN
0
0
EX.
COMMON
WOMEN
OCT 0 3 2012
RUT CENTER
ITT SPACE, NO WORK
FIRST FLOQR OFFICE: Nf U
SCALE: 1/8" = 1' -0"
AREA OF GIVE BACK = 5,331 SF
12 -02 -11
C:1Documents and Settlngs\Ali Users\Documents \CAD 11987 - 19891870 -71PDS DOWNSTAIRS 06- 28- 121CD'S 08-10 -12rev 09- 19- 12\T- 1- T- 3.DWG, T- 1,10/1/201.211:18:32 AM
REVISION N0. i
ba".-Ibe
DEMO NOTES:
I. REMOVE EXISTING GRIDS AND LIGHTS AS SHOWN.
2. RE- SWITCH LIGHTING 5Y AREA AND IN OPEN AREAS, MULTI -LEVEL
SWITCHING.
3. RELOCATE EXISTING LIGHT FIXTURES.
4. REMOVE UNUSED FIXTURES.
SPACER BAR, OR OTHER
SUITABLE SYSTEM, TO KEEP
PERIMETER COMPONENTS FR
SPREADING APART.
13/
MN. AT W- ATTACHED WALLS
NOTE:
ATTACH CEILING AND GRID
TO WALL ANGLE (MOULDING)
AT TWO ADJACENT WALLS
VIA POP RIVETS.
4 142 GA. WIRES WITHIN 2"
OF CROSS TEE
CONNECTION ARRANGED
AT 90' FROM EACH
OTHER AND AT AN
ANGLE NOT EXCEEDING
45'. LOCATE RESTRAINT
PANELS AT 12' O.G. IN
EACH DIRECTION AND
WITHIN 6' OF EACH WALL..
NOTeS:
NOTg:
SUSPENSION WIRES TO BE 12
GAGE AT 4' O.C. WI
ATTACHMENT DEVICES
leW•IFFWAS
5 WITHIN 1 IN 6
UNLESS COUNTER SLOPING
WIRES ARE PROVIDED
I) MAIN BEAMS TEES AND CROSS TEES
MUST BE HEAVY DUTY W/ CONNECTION
STRENGTHS OF 100 POUNDS IN
COMPRESSION 4 TENSION.
2)
CEILING AREAS GREATER THAN 1000
SF MUST HAVE LATERAL FORCE
BRACING VIA DIAGONAL SPLAY WIRES,
LIMITING MOVEMENT TO LESS THAN 1/4"
RESTRAINED CEILING DETAILS (MEETS IsC 2otA WIZ 41Yii n'635 ASTM C 636 AND ASCE 1-02)
3) LIGHT FIXTURES TO RE POSITIVELY
ATTACHED TO MAIN AND CROSS TEES.
AND IF OVER 56., MUST BE
INDEPENDENTLY SUPPORTED.
4)
5)
PARTITIONS GREATER THAN 6' TALL
NEED INDEPENDENT BRACING VIA
SPLAY WIRES (SEPARATE FROM ANY
OTHER WIRES). PARTITIONS 6' OR LESS
NO ATTACHMENT IS REQUIRED.
SPRINKLER HEAD PENETRATIONS MUST
HAVE 2" OVERSIZED TRIM TO ALLOW 1"
b) MOVEMENT IN ALL DIRECTIONS.
MANUFACTURER CERTIFICATION OF
COMPONENT PERFORMANCE AND
1) PaRIOSIICINiE:11655461 00
giNG4r166198116TEEFISRREIWROZINT OR
FULL HEIGHT WALL PARTITION THAT
BREAKS THE CEILING SHALL BE
8) PROVIDED.
ALL CROSS TEES SHALL BE CAPABLE
OF CARRYING THE DESIGN LOAD
9) WITHOUT EXCEEDING DEFLECTION
EQUAL TO )360 OF ITS SPAN.
ALL WIRE TIES ARE TO BE THREE TIGHT
TURNS AROUND ITSELF WITHIN 3 INCH.
SCALE
L ICzHTINCs CALCULATIONS:
1. REMOVE AND RELOCATE 21 EXISTING 2'X4' FLUORESCENT FIXTURES AS SHOWN NO CHANGE IN
Isl. %'i WATTAGE
I` 4. "'MOVE 2 EXISTING I'X'4' FLUORESCENT FIXTURE 1 X 88 W = 88 WATTS
INSTALLED FLUORESCENT FIXTURES AS SHOWN NO CHANGE IN WATAGE
NEW NOTES:
I. EXTEND EXISTING GRID INTO NEW SPACES AS SHOWN.
2. MATCH TILES OF EXTENDED GRID
3, NEW SWITCHING 5Y AREAS AND MULTILEVEL SWITCHING N LARGE OPEN
SPACES.
TYPES
REMOVE EXISTING GRID AND
LIGHTS AS SHOUIN
REMOVE EXISTING DOOR AND
HEADER, PATCH CEILIN
08 -10 -12
MOVE EX. GRID
R EXTENDED
RRIDOR
tf
INSTALL NEW CIELING GRID,
LIGHTS AND TILES EXTENDING
EXISTING GRIDS
SEE SHEET T -3 FOR PATHWAY
LIGHTING AND EXITING SIGNS
REFLECTED CEILING PLAN: DEMO
SCALE: I /8" = 1' -0"
AREA OF GIVE BACK a 5,331 SF
12 -02 -11
REVIEWED FOR
CODE COMPLIANCE
APPROVED
OCT 0 9 2012
I∎Zal
Pla OWE
eErAim
■.
-I I CA Mill
:-.!!
mil mum
0131 I•Mil
03� ES0
NEW 1 HOUR GYP BD CEILING TO
MATCH EXISTING
DF.
ION NO.:
REFLECTED CEILING PLAN: NEW
SCALE: 1/8" O 1' -0"
AREA OF GIVE 15ACK = 5,331 SF
12 -02 -H
C: \Documents and Settinas\AII Users\ Documents \CAD\19R7.1989\R7n4_71PrA IlClWNATOIRS nR- 7tL17\P_n'c nszin.47new alim_4MT_4_T_9 rhuun_
REC ,
CITY Or
OCT0
0
PERMH`?
•r .
AAM /MAA •J1e..1I emu
SITE PLAN
5,3'18F
TEN4NT
AREA
Q
i
!i8
toeu of wow
1ST FLOOR KEY PLAN
ELECTRICAL
SITE & BUILDING STATISTICS
— BUILDING CODE: IBC 2009
— BUILDING TYPE OF CONSTRUCTION: III —B SPRINKLERED
— OCCUPANCY GROUP:
— BUILDING AREA
FIRST FLOOR=
SECOND FLOOR=
TOTAL=
B
33,039 S.F.
33,467 S.F.
66,506 S.F.
— TENANT AREA OF WORK (AFTER WALL RELOCATION)
SUITE 101 = 5,337 SF
TENANT WORK AREA= 5, 337 SF
LEGAL DESCRIPTION
PARCEL B OF TUKWILA SHORT PLAT 89 -1 —SS, RECORDED UNDER
AUDITOR'S FILE #8904120877.
TAX ID. NUMBER
271600- 00- 0070-06
SCOPE OF WORK
REMOVE EXISTING NONBEARING WALLS, AND CONSTRUCT NEW
NONBEARING WALLS, REMOVE PORTION OF GRID AND INSTALL
NEW GRID EXTENDING FROM EXISTING, RELOCATE LIGHTS, HVAC,
MODIFY ELECTRICAL AND SPRINKLERS AS REQDUIRED FOR NEW
WALLS.
SEPARATE PERMITS:
HVAC, SPRINKLER, FIRE ALARM, ELECTRICAL
C:IDocuments and Setts
•
REVISIONS
s tali he made to the scope.
c f kt!rrl th ; t prior approval of
f iuE1 ig Divisiom
-,.. _ ":s will require a new l,' ^,1
M c dc' : °onEl plan re "':7' ,
SEPARATE PERMIT
REQUIRED FOR:
Crtlechicd
Cry
Was0
City of Tukwila
BUILDING DIVISION
FILE COPY
Per tit No. I?2Q 9
Pl r r visw approval is subject to errors and omissions.
of vcnstruction documents does not authorize
.'Ion Of any adopted code or ordinance. Receipt
: roved Field Copy and conditions is acknowledged:
d:
By
Date:
City Of Tukwila
BUILDING DIVISION
CORREgsTION
LT R#
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 2 8 2012
A-S
City of Tukwila
BUILDING DIVISION
bL22Q
RECEIVED
CITY OF TUKWILA
SEP 2 0 2012
PERMIT CENTER
1AU UserssDocuments \CAD11987- 198918704 -71PDS DOWNSTAIRS 06- 28- 121CD'S 08- 10- 121T -0.d
PHONE (206) 433 -8997 snm DATE DESCRIPTION PROJECT 8704 -7
GATEWAY CORPORATE CENTER: BLDG 7 FAX 246-8369
l
08-14-12 sugMlT TO out pRl►wl�f eY KEHI,.E a ""
�De -t4-1Z SUBMIT FOR PERMIT
REGiSTE ED
H , TECT
�,, i► - - DATE 08- 10 --12
TENANT IMPROVEMENT FOR PDS TECH. INC 01 0 Erm - -
' ° 12720 GATEWAY DRIVE SUITE 101 .- CHECKED BY DAVID s o
191 3 BON AIR DR
TUKWILA, WASHINGTON SEATTLE, WASHINGT • DATE -
architect 9 8 1 1 6
DEMO NOTES:
1. REMOVE ALL WALLS AND DOORS AS SHOWN. SAVE DOORS TO BE
REUSED IF POSSIBLE.
2. PATCH AND REPAIR ALL WALL, FLOOR, AND CEILING
3. REMOVE FINISHES AS REQUIRED
4. CAP ANY PLUMBING AND NOTE ON AS BUILT DRAWING
5. REMOVE ANY ELECTRICAL NOT USED TO ABOVE CEILING, TO NEW
J -BOX WITH NOTE ON PANEL AND CIRCUIT NUMBER LISTED.
5. RELOCATE HVAC AS REQUIRED FOR DEMO AND NEW WORK. SEPARATE
FROM ITT SYSTEM
DOOR SCHEDULE EXFSTIN:
El EX. 3'X1' SOLID CORE 20 MIN. DOOR AND WOOD FRAME, LOCKSET
(INSIDE LEVER TURNS FREE FOR EXIT).
DOOR SCHEDULE NEW:
NEW OR REUSED DOORS WITH NEW LEVER HANDLES, MATCH EXISTING
2 -4 3' -0" X 1' -0" S.C. WOOD (STAINED) WITH WOOD JAMBS,
8,8,9 LOCKSET (LEVER), 1 1/2 PAIR BUTTS, SILENCER, WALL STOP
1,5 3' -0" X 1' -0" S.G. WOOD (STAINED), WOOD JAMB, LATCHSET, 1
1,10,11 1/2 PAIR BUTTS, SILENCERS, WALL STOP
12,13 3'- 01'X1' -0" S.C. WOOD (STAINED), WOOL? JAMB, LOCKSET,1 1/2 PAM
BUTTS, SMOKE GASKETS, WALL STOP (20 MIN RATED DOOR)
ROOM SC4WULE:
1 -6 FLOOR: NEW CARPET
9,10 BASE: NEW BASE
WALLS: EX. TO BE REPAINTED (EE)
NEW WALLS PAINT (EE)
CEILING: EX. SUSP.ACOUST IC MODIFY AS REQUIRED
1,8 FLOOR: NEW VGT
11,12 BASE: NEW RUBBER BASE
WALLS: NEW GYP BD PAINT (REPAINT EXISTING)
CEILING: EX. SUSP ACOUSTIC
WALL TYPES:
A. NEW NON BEARING INTERIOR PARTITION: 3 5/8" X 25 GA STEEL STUD
AT 24" O.C. TO CEILING ABOVE (SI 1$ SOUND INSULATED)W/ 5/8" GYP BD
EACH SIDE.
B. IN FILL WALL: MATCH EXISTING STUD WALL FOR THICKNESS OF STUD
AND TYPE OF STUD, 5/8" GYP BD EACH SIDE (MATCH EXISTING).
C. NEW 11 -1OUR RATED WALL TO MATCH EXISTING (WPI200), 5/8" TYPE 'X'
GYP BD EACH SIDE TO 1 HOUR CEILING (SEE CROSS SECTION)
POWER POLE OR FURNITURE WHIP VERIFY
WITH TENANT. ALLOW FOR 3 CIRCUITS
(CLEAN, 2 DIRTY) PER POWER POLE SERVING
UP TO 3 WORKSTATIONS
STANDARD DUPLEX OUTLET AT STANDARD
HEIGHT. VERIFY LOCATION WITH TENANT
MUD RING WITH PULL STRING FOR PHONE AND
Q DATA (PHONE AND DATA 5Y TENANT)
POWER AND PHONE/DATA LOCATIONS SHOWN ARE
PREFERED LOCATIOS, HOWEVER IF THERE ARE
EXISTING OUTLETS CLOSE BY, THEN VERIFY WIN NE
TENANT IF NE EXISTING WILL WORK
NOTE:
SEE SHEET t -3 FOR EXIT DISTANCES AND EXIT
PATHWAY LIGHTING
SEE T -3 FOR WALL AND DOOR DETAILS
SEE T -3 FOR CORRIDOR SECTION
EX, THEORY 1
EX. STA
F I EX. LAB 3
REMOE EXISTING WALLS
AND r:10ORS AS SHOU,N
EX
THEORY 2
III \
1 = = ===
LT
IT\
if
EX, TH
EERY 3
J1
EX, LRC
r- \ -i
�/ i
IL
EX
HALLS
EL
It. FIRST FLOOR OFFICE: Polo
SCALE: I" or 14 -0"
100' -6
STORAGE
AREA OF GIVE SACK : 5,331 SF
12 -02 -11
11' -.r7'
12' -5
11' -6
14' -11
POWER POLES
COPIERPLOTFAX
11' -84'
DEEN
OFFICE
I
N
COPIER,PLOT,FA
A
SI
ITT SPACE, NO WORK
FIRST FLOOQR OFFICE: NFW
SCALE: tip = 1' -0"
OPEN
OFFICE
�x
■
N
I
11' -5'
i
oFFia 3
6181
11' -0 4' -6
•
EXT. I HOUR
1 1
WALL
ITT
MEN
o
0
EX.
COMMON
WOMEN
0
0
D.F.
SI
CONFgRENCE
n
16'X21' :336
SF191 /15 :2J OCC.
SINGLE EXIT
EY-
i.
EX. HALL
ou
0
EX.
COMMON
WOMEN
0
0
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 2 8 2012
City of Tukwila
BUILDING DIVISION
z68
AREA OF GIVE BACK ; 5,331 SF
12 -02 -11
C:\Documents and Setltin$s1Ail UserslDocumentiACAD11987- 198918704 -71PDS DOWNSTAIRS 06- 28-121CC'S min.19m nA.112.1917_1_T num
RECEIVED
CITY OF TUKWILf
SEP 2 0 2012
PERMIT CEN TER
t.
0
co
g
g
08 -10 -12
A
t
0
U
L`!
N
1
<141 44
401111=1■00712110.
a3
SS O
00
GATEWAY CORPORATE CENTER: BLDG 7
T =I
T I ni4ni t4 .1.14.4n n.
DEMO NOTES:
1. REMOVE EXISTING GRIDS AND LIGHTS AS SHOWN.
2. RE- SWITCH LIGHTING SY AREA AND IN OPEN AREAS, MULTI- LEVEL
SWI TCr'-I I NG.
3. RELOCATE EXISTING LIGHT FIXTURES.
4. REMOVE UNUSED FIXTURES.
SPACER BAR, OR OTHER
SUITABLE SYSTEM, TO KEEP
PERIMETER COMPONENTS
SPREADING APART.
MK AT Ito- ATTACHED WALLS
NOTE:
ATTACH CEILING AND GRID
TO WALL ANGLE (MOULDING)
AT TWO ADJACENT WALLS
VIA POP RIVETS.
4"12 GA. WIRES WITHIN 2"
OF CROSS TEE
CONNECTION ARRANGED
AT W FROM EACH
OTHER AND AT AN
ANGLE NOT EXCEEDING
45'. LOCATE RESTRAINT
PANELS AT 12' O.G. IN
EACH DIRECTION AND
WITHIN 6' OF EACH WALL.
NOTE:
SUSPENSION WIRES TO BE 12
GAGE AT 4' O.C. W/
ATTACHMENT DEVICES
-�-
Repo 15 = '�L B WITHIN I IN 6
UNLESS COUNTER SLOPING
WIRES ARE PROVIDED
R(M� ERT�S
NOTES:
1) MAIN BEAMS TEES AND CROSS TEES
MUST SE HEAVY DUTY W/ CONNECTION
STRENGTHS OF 100 POUNDS IN
COMPRESSION 4 TENSION.
2)
CEILING AREAS GREATER THAN 1000
SF MUST WAVE LATERAL FORCE
BRACING VIA DIAGONAL SPLAY WIRES,
LIMITING MOVEMENT TO LESS THAN 1/4"
3) LIGHT FIXTURES TO BE POSITIVELY
ATTACHED TO MAIN AND CROSS TEES.
AND IF OVER 56*, MUST BE
INDEPENDENTLY SUPPORTED.
4)
PARTITIONS GREATER THAN 6' TALL
NEED INDEPENDENT BRACING VIA
SPLAY WIRES (SEPARATE FROM ANY
OTHER WIRES). PARTITIONS 6' OR LESS
5) NO ATTACHMENT IS REQUIRED.
SPRINKLER HEAD PENETRATIONS MUST
HAVE 2" OVERSIZED TRIM TO ALLOW 1"
6) MOVEMENT IN ALL DIRECTIONS.
MANUFACTURER CERTIFICATION OF
COMPONENT PERFORMANCE AND
1) IOpi i l I 0
;Ir cAraga '1't6T�' NT OR
FULL HEIGHT WALL PARTITION THAT
E5REAKS THE CEILING SHALL BE
8) PROVIDED.
ALL CROSS TEES SHALL 1:3E CAPABLE
OF CARRYING THE DESIGN LOAD
9) WITHOUT EXCEEDING DEFLECTION
EQUAL TO )fro OF ITS SPAN.
ALL WIRE TIES ARE TO BE THREE TIGHT
TURNS AROUND ITSELF WITHIN 3 INCH.
RESTRAINED CEILING DETAILS (MEETS IBC 206i ge T 635 AVM C 636 AND ASCE 1 -02)
TYPES
SCALE
LIG4TtN CALCULATIONS:
1. REMOVE AND RELOCATE 21 EXISTING 2'X4' FLUORESCENT FIXTURES AS SHOWN NO CHANGE IN
I` �'i WATTAGE
4. REMOVE 2 EXISTING 1'X'4' FLUORESCENT FIXTURE 1 X SS W = 88 WATTS
INSTALLED FLUORESCENT FIXTURES AS SHOWN NO CHANCE IN WATAGE
NEW NOTES:
1. EXTEND EXISTING GRID INTO NEW SPACES AS SHOWN.
2. MATCH TILES OF EXTENDED GRID
3. NEW SWITCHING 8Y AREAS AND MULTILEVEL SWITCHING IN LARGE OPEN
SPACES.
I
���■�i■_..■.:a�_.,....• =1 rr�i
II r ��� l
11111111111111M11111111111111111111111111111111111111 I
r ri
r:;_.maw �M�
�■ II
REMOVE EXISTING GRID AND
LIGHTS AS SHOWN
REMOVE EXISTING DOOR AND
HEADER, PATCH CEILI
IL _
CIS-
�xl I I
CZDI: Ii -C =_I
i I I I I I I I
I I r ri-P'l I I r ril
3
O
O
O
REMOVE EX. GRID
FOR EXTENDED
CORRIDOR
0
re
0
4
a
14% CA
E
I I
N
O
N N
W
INSTALL NEW CIELING GRID,
LIGHTS AND TILES EXTENDING
EXISTING GRIDS
SEE SHEET T -3 FOR PATHWAY
LIGHTING AND EXITING SIGNS
I .EFLECTF-O-__GEI ,.ING FLAN: DEMO
SCALE: V` I 1'4"
►- +rl ►-:�-�
AREA OF GIVE BACK = 5,331 SF
12 -02 -11
11 I I r: MA I I IHHI
=I
13=
MINIM
�--�N► 7
Prail
/IM11
11111/1
ie:
PM PM
MI MI
Ell
mak
REF,ECTE2 PLAN: NEW
SCALE: -l$v = 1' -0"
1111.1121=111111111■11
RIM
MINIM I ��
illibrom
: _ I!h
WM iii
MI pi pir=
Fr 0
NEW 1 HOUR GYP 80 CEILING TO
MATCH EXISTING
D.F.
O
O
REVIEWED FOR
E COMPLIANCE
APPROVED
SEP 2 8 2012
City of Tukwila
WING DIVISION
I
AREA OF GIVE BACK = 5,331 SF
12 -02 -11
C:\Documents and Settings1All Users\ Documents \CAD\1987 - 1989\8704 -7\PDS DOWNSTAIRS 06- 28- 121CD'S 08- 10- 12 \T- 1- T- 3.OWG, T -2), 8/14/2012 1:17:25 PM
RECEIVED
CITY OF TUKWIL
SEP 2 0 2012
PERMIT CENTER
E
I Li
-
:;,U-
OGCUP
j
8 1/ 2
� ==
I
isa -1
II
iii,__ -L-_
74-- -
1111111—
�/
I
Mil
II
1 - --I--
CZDI: Ii -C =_I
i I I I I I I I
I I r ri-P'l I I r ril
3
O
O
O
REMOVE EX. GRID
FOR EXTENDED
CORRIDOR
0
re
0
4
a
14% CA
E
I I
N
O
N N
W
INSTALL NEW CIELING GRID,
LIGHTS AND TILES EXTENDING
EXISTING GRIDS
SEE SHEET T -3 FOR PATHWAY
LIGHTING AND EXITING SIGNS
I .EFLECTF-O-__GEI ,.ING FLAN: DEMO
SCALE: V` I 1'4"
►- +rl ►-:�-�
AREA OF GIVE BACK = 5,331 SF
12 -02 -11
11 I I r: MA I I IHHI
=I
13=
MINIM
�--�N► 7
Prail
/IM11
11111/1
ie:
PM PM
MI MI
Ell
mak
REF,ECTE2 PLAN: NEW
SCALE: -l$v = 1' -0"
1111.1121=111111111■11
RIM
MINIM I ��
illibrom
: _ I!h
WM iii
MI pi pir=
Fr 0
NEW 1 HOUR GYP 80 CEILING TO
MATCH EXISTING
D.F.
O
O
REVIEWED FOR
E COMPLIANCE
APPROVED
SEP 2 8 2012
City of Tukwila
WING DIVISION
I
AREA OF GIVE BACK = 5,331 SF
12 -02 -11
C:\Documents and Settings1All Users\ Documents \CAD\1987 - 1989\8704 -7\PDS DOWNSTAIRS 06- 28- 121CD'S 08- 10- 12 \T- 1- T- 3.OWG, T -2), 8/14/2012 1:17:25 PM
RECEIVED
CITY OF TUKWIL
SEP 2 0 2012
PERMIT CENTER
DOUBLE KITCHEN
STAINLESS STEEL
SINK WITH
DEADENING, WRIST
HANDLES AND
GOOSE NECK SWIVEL
FAUCET
t� rsarrasomm
RUBBE
BA
4" P.L.
BACKSPLASH
ADJUSTABLE
SHLEVING
NEW BREAK ROOM CABINET
SCALE: 1/4" = l'-0"
CABINET YPEQS.
CABINETRY TO BE PLASTIC LAMINATE FLUSH OVERL,4Y;'k $; CEALED
I`;
HINGES, INTERIOR TO BE WHITE PLASTIC LAMINATE, OR,A GUIDES � ° ,t..
TO BE SELF CLOSING METAL, SILENCERS ON DOORS, 15
NICKEL OR CHROME WIRE PULLS (4 ").
SEPARATE EXIT FOR
CONFERENCE Mt
BALANCE NEEDS ONLY ONE EXIT=
EXISTING COMMON LOBBY
WITH EXITING AND PATHWAY
LIGHTING
FLOOR Pn.AN EXIT D
SCALE: 3/32" = 1' -0"
STANQE
II
1
5TOR
12"1 5F
1/500225
OC
EXISTING COMMON LOBBY
WITH EXITING AND PATHWAY
LIGHTING
5 R.
015F
1/500 =20
OCC.
FLOOR PLAN EXIT PATHWAY
SCALE; 3/32" = I' -0"
II II
'4JI -LOAD
CONF. = 21 OCC. SEPARATE EXIT
OPEN OFFICE 1 = 28 OCC.
OPEN OFFICE 2 = 10 OCC.
STORAGE RMS. = 0 OCC. UNDER .5 OCC. TOTAL
!BALANCE O ICE = 10 OCC
TOTAL OCCUPANT LOAD = 48 OCCUPAN
ONE EXIT,
3
2x4 WOOD STUD WALL (SEE SCHEDULE)
2x WOOD SLOGGING
2 i/2" WOOD CASING - STAINED
1 1/2" x WOOD JAMB - STAINED
5/8" x WOOD STOP - STAINED
SOLID CORE WOOD DOOR
STAINED
5/8" GYP BD. EACH SIDE
Wool) FRAME pETA I L
SCALE: 1 -1/2" • 11.0"
MACK TRACK
ALUMINUM BREAK
METAL CUT
BOTTOM SNAP- IN
ALUMINUM le
FRAME TO AL
GLASS CHANGING
GASKETS 1/4"
[WILL WITH
WALL TO WINDOW
SCALE: 1 -1/2" • I' -0"
SECTION
SILL BELOW
DEEP LEG TRACK
ATTACH • SILL AND
CEILING GYP. D. TO
STEEL TRACK PROVIDE
1/2" AIR SPACE TO
STEEL STUD AND
ATTACH GYP. BD. TO
STUD
TAPING
COMPOUND OVER
PAPER - COVERED
CORNER BEAD.
ILLUMINATED EXIT SIGNS WITH PATHWAY LIGWITNG AND BACK UP
BATTERY
PATHWAY LIGHITNG WITH BACK UP BATTERY
NO
EME - c.: LIGHTING FACILITIE
TO FRO/ INITIAL LUMINA
AVERAGE • FOOT -CAMP
POINT OF 0.1 -CAN,
OF EGRESS AT FL
SHALL BE FERMI
AVERAGE AND • IN
FOOT -CAND - AT THE
TIMED ON. A MAXIMUM -
RATIO OF 40 TO 1
L BE ARRANGED
THAT IS AT LEAST AN
AND A MINMUM AT ANY
MEASURED ALONG THE PATH
EVEL ILLUMINATION LEVELS
DECLINE TO Oh FOOT- CANDLE
AT ANY POINT OF 006
OF THE EMEaGANCY LIGHTING
-MINI IM ILLUMINATION
L NOT BE EXCEEDED.
SECTION
FOR WALLS GREATER
THAN 8'- 0" IN
WIDTH WITHOUT AN
INTERSECTING WALL
PROVIDE 12ga. WIRES
SPLAYED • 45 TO AN
EYE SCREW • ROOF
AND TOP OF WAG.
Aei niniu.u.u....■rri■umu•u•u•■i►
ATTACH TOP RUNNER
TRACK TO CEILING
GRID WITH 2 - +16
x 11/5" LONG
SCREWS AT 2'- 0"0.0.
TYPICAL STUDS WALL PER SCHD.
(FOR WALL INSULATION SEE
PLAN) 5/0" GYP. 8D. EA.
SIDE (FLUSH FINISH).
SEEMFLECTEDAL
CEILING PLAN
TYP. WALL TO REFLECTED CE I L INCA
SCALE:1 -1/2" a 1' -0"
TYPICAL WALL
FRAMING
ATTACH BOTTOM
TRACK TO CONC.
FLOOR W/ POWDER
DRIVEN ANCHORS, HILTI
OR APPROVED 1" EMBE
AT24 "O
11/2" RUBBER
BASE •CARPET
5/a" GYP. BD.
(TYPE 'X' • FIRE
RATED WALLS.)
ACOUSTICAL BLANKET
• SOUND WALL.
CONC. SLAB ON GRADE
WALL TO SLAB
SECTION
CAULK GYP. BD. TO FLOOR
a ALL SOUND AND INSUL.
WALLS
SCALE: 1 -I/2" • 11 -0'
PAINT BL
N.1.4--19
3/4" x 2"
FILLER BLACK
GASKETS 1/4"
EACH SIDE OF
FILLER
WALL TO MULLION
SCALE: I -I/2" r j'.f1Jr
SECTION
SILL BELOW
DEEP LEG TRACK
ATTACH • SILL
AND CEILING -
DO NOT ATTACH
GYP. ED. TO
TRACK
STEEL STUD -
ATTACH GYP.
ED.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 2 8 2012
" JOISTS SIM. TO
EXISTIG HALL
USE 2 X10 SCREWS
EACH JOIST TO EACH S
1'
1
City of Tukwila SE
BUILDING DIVISION
NON - COMBUSTIBLE
31/2" STL. STUDS
SAME 45 EXIST'G
HALL., $4" 0.C.
1
NON -RATED
SUSP. CLG.
ION
/8" TYPE
'X' GYP. BD.
(SOUND INSUL IF
SHOWN ON PLAN)
RECEIVED
CITY OF TUKWILA
LOOR
CORRIDOR SECTION (1 -HOUR)
SCALE: 3/8" • 11.0"
C: \Documents and Settings\AII Users\ Document s \CAD11987- 19RA1R7nd.7konR nemAn IQTeIoe eo 4.fl/�nI An •..... ---
SEP 2 0 2012
PERMIT CENTER
SECTION
08 -10 -12
a
8
V
0
z
0
0
C
A
g e ®®
M
O)C Ot0
H
FO)0
�
N
I pZ
* =
Q Q
88 z w.
w 0 4J
aId
(0 a
o
CoU)o)
U
CD
11[1!!!!!!1] U
cc5
GATEWAY CORPORATE CENTER: BLDG 7
T -3