Loading...
HomeMy WebLinkAboutPermit D12-278 - RED WING SHOES - TENANT IMPROVEMENTRED WING SHOES 17135 SOTJTHCENTER PY D12-278 City aeTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 -431 -2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 2623049069 Address: 17135 SOUTHCENTER PY TUKW Suite No: Project Name: RED WING SHOES Permit Number: D12-278 Issue Date: 09/14/2012 Permit Expires On: 03/13/2013 Owner: Name: KTM GROUP LLC Address: 635 HIGH SCHOOL RD NE , BAINBRIDGE ISLAND WA 98110 Contact Person: Name: STEVE RAGE Address: 10914 181 LN NW , ELK RIVER MN 55330 Contractor: Name: MICHAEL JENSEN CONST LLC Address: 7205 MCDONALD AV , GIG HARBOR WA 98335 Contractor License No: MICHAJC934NM Lender: Name: RED WING SHOE COMPANY Address: 314 MAIN ST , RED SHOE MN 55066 Phone: 612 817 -8024 Phone: 253 370 -2800 Expiration Date: 08/23/2013 DESCRIPTION OF WORK: DEMOLISH EXISTING INTERIOR FINISHES, INSTALL NEW SEPARATION WALL BETWEEN SALES FLOOR AND STOCKROOM, INSTALL NEW FLOORING, PAINT WALLS, PAINT CEILING, INSTALL NEW EXPOSED SPIRAL HVAC DUCT, INSTALL OWNER PROVIDED LIGHT FIXTURES, FURNISH AND INSTALL NEW STOCKROOM LIGHTING, AND INSTALL OWNER FURNISHED FIXTURES. (SEPARATE PERMIT TO BE PULLED FOR RACK STORAGE) Value of Construction: $50,000.00 Fees Collected: $1,583.80 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: IIIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -278 Printed: 09 -14 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: O l\ I`l 1 V2 I hereby certify that I have read and = ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie , i , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �� ? Date: 9 - /y- Z Print Name: / /� %� e / _ad 5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12 -278 Printed: 09 -14 -2012 7: All construction shall be done in conforzie with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) doc: IBC -7/10 D12 -278 Printed: 09 -14 -2012 25: Aisles leading to required exits shall betvided from all portions of the building and tlequired width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 37: ** *PLANNING DEPARTMENT CONDITIONS * ** 38: Signs are not approved as part of this permit. A separate sign permit is required. doc: IBC -7/10 D12 -278 Printed: 09 -14 -2012 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Project No. Date Application Accepted: Date Application Expires: For o1 we use on! CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17135 South Center Parkway Tenant Name: Red Wing Shoes King Co Assessor's Tax No.: 2623049071 Suite Number: lv i/1- PROPERTY OWNER Name: Steve Hage Name: KTM Group City: Elk River State: miN Zip: 55330 Address: 635 High School RD NE Email: steve.hage @sh2companies.com City: Bainbridge Island State: WA Zip: 98110 CONTACT PERSON — person receiving all project communication Name: Steve Hage Address: 10914 181st LN NW City: Elk River State: miN Zip: 55330 Phone: (612) 817 -8024 Fax: Email: steve.hage @sh2companies.com GENERAL CONTRACTOR INFORMATION Name: Ivy Company Name: Company Name: Architect Name: Ron Sorce Address: Address: 121 South Wilke Road City: f1..„ City: State: Zip: Phone: (847) 392 -2600 Fax: (847) Phone: Fax: State: Contr Reg No.: Exp Date: Fax: Tukwila Business License No.: (44. no n 1 60 Ul V( 1 1 e'■ I H: \ApplicationsWorns- Applications On Line\2011 Applications \Permit Application Revised - 8 -9-I 1.docx Revised: August 2011 hh Floor: First New Tenant: ® Yes ❑..No ARCHITECT OF RECORD Name: Ivy Company Name: Sorce Architecture Company Name: Architect Name: Ron Sorce �/� fq t ,, C,T ` }/� Address: 121 South Wilke Road City: f1..„ Clty: Arlington Heights State: IL Zip: 60005 Phone: (847) 392 -2600 Fax: (847) 394 -4972 Email: ron @rpsarchitects.com State: ENGINEER OF RECORD Name: Ivy II UN S O.c !`.0 V� Company Name: Address: b im �/� fq t ,, C,T ` }/� Engineer Name: City: f1..„ CA., 9C- State: 1 Zip: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Ivy II UN S O.c !`.0 V� Address: b im �/� fq t ,, C,T ` }/� City: f1..„ CA., 9C- State: 1 Zip: IAPI Page 1 of 4 BUILDING PERMIT INFORMATIO 206 -431 -3670 Valuation of Project (contractor's bid price): $_ 50,000 Describe the scope of work (please provide detailed information): Demolish existing interior finishes, install new separation wall between sales floor and stockroom, install new flooring, paint walls, paint ceiling, install new exposed spiral HVAC duct, install owner provided light fixtures, furnish and install new stockroom lighting install owner furnished fixtures Existing Building Valuation: $ Will there be new rack storage? ® Yes Cl.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq II): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 190 Compact: Handicap: 5 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: VI Sprinklers El Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicationsWorns- Applications On Line12011 ApplicationsWermit Application Revised - 8 -9-1 I.docr Revised: August 2011 bh Page 2 of 4 Existin : Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,750 1,750 0 0 1II -B M 2nd Floor 3rd Floor Floors thni Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq II): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 190 Compact: Handicap: 5 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: VI Sprinklers El Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicationsWorns- Applications On Line12011 ApplicationsWermit Application Revised - 8 -9-1 I.docr Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction = In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review = Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ' • : A HI ' i Ao b A t. Signature: AGENT: Print Name: 1.F V :S e 14 Q G-t Mailing Address: 09 1 L (, Lv l H:\ Applications \Forms- Applications On Line\201 I Applications \Pemtit Application Revised -- 8 -9-I l.doca Revised: August 2011 bh Date: 06, iku Ci 12. Day Telephone: to (Z '5( 4502 Le eV L It- M o- J S 3 3 0 City State Zip Page 4 of 4 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049069 Permit Number: D12-278 Address: 17135 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/20/2012 Applicant: RED WING SHOES Issue Date: Receipt No.: R12 -02606 Payment Amount: $961.65 Initials: JEM Payment Date: 09/14/2012 10:28 AM User ID: 1165 Balance: $0.00 Payee: SH2 COMPANIES INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5251 961.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 957.15 640.237.114 4.50 Total: $961.65 doc: Receiot -06 Printed: 09 -14 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049069 Permit Number: D12 -278 Address: 17135 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/20/2012 Applicant: RED WING SHOES Issue Date: Receipt No.: R12 -02396 Payment Amount: $622.15 Initials: JEM Payment Date: 08/20/2012 11:23 AM User ID: 1165 Balance: $961.65 Payee: SH2 COMPANIES INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5241 622.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 622.15 Total: $622.15 doc: Receiot -06 Printed: 08 -20 -2012 INSPECTION RECORD Retain a copy with permit, ti. INSPECTION NO. • CITY OF TUKWILA BUILDING DIVISION 6 6300 Southcenter Blvd., #100, Tukwila. WA 981'88 r- (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 7> r 2- _217f PERMIT NO. Project' ,IA � Type1ln /ecti n:B V ' A t Address: t 5 �� #Instructions: k'W Date Called: Spetci''al Date Wanted:. 7 --.2.121, Q P (S -• (7,- P.m. Requester: Phone Na:__ Phone -3'7o -24(4 0 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: o E NVis (eTe Inspecto e4 )tjj 1) • D REINSPECTION FEE REQUIRED Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: / -- Imo- • • INSPECTION RECORD Retain a copy with permit. I x`2-18 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type r.JnsPection: (.A-M, /A 6 CD1::(2 A w%I..YZ - . fvokieZ .)(sq-0.7w-f Address: le7 I 1 13.5 _Sc Date Called: Special Instructions: d Date Wanted: - 3 _) oil Ply hiNgi-0/1 1 Yearrwrt -- A 11FhI Requester: Phone NS? -110 -- -/ -rr00 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS:® c\-1 CD1::(2 A w%I..YZ - . fvokieZ .)(sq-0.7w-f -Lfs, 3 _) oil Ply hiNgi-0/1 1 Yearrwrt -- A 11FhI nspe or: Date: 14 ' \4 mot I " 2 - �i' REI SPECTION FEE REQUIR . Prior to rjext inspection. fee must be pai at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Laurie Anderson From: Sent: To: Subject: Jennifer Marshall Monday, October 29, 2012 9:59 AM Laurie Anderson RE: Refunds Here is the table updated to include the payee. To Finance Project Name Payee Permit No. Refund Amt 08/21/2012 Starbucks Coffee Poitras Sign & Lighting EL12 -0758 $60.48 10/01/2012 August Residence Northwest Permit Inc EL12 -0836 $50.40 10/01/2012 Sports Authority Touch Tone Communications Charles Brook EL12 -0839 $76.40 10/01/2012 Adame Residence Northwest Permit Inc EL12 -0691 $47.88 10/01/2012 JS Dental Clinic Joselito Santos PG12 -140 $153.72 10/11/2012 Red Wing Shoes SH2 Companies D12 -278 $178.80 10/24/2012 Interline Brand All Weather Rooftop Solutions D12 -339 $306.95 From: Jennifer Marshall Sent: Wednesday, October 24, 2012 1:11 PM To: Laurie Anderson Subject: Refunds Good afternoon Laurie, f :Alt ✓136 12- #3tpItoS0 1°1511. G<-0 3101111 10�f5) ► � K 4- 611P &O Ic/ISj l z CYO" 3616'17 1oAsi C►-j7Ri to /z211 1 It seems we have had a lot of refund requests as of late. I was going through my records and wanted to check on the following (one is quite old and the others I would have thought would have made the 10/19 check run... I want to make sure they hadn't slipped through the cracks). Please let me know if you need additional information to match these up with your records. To Finance Project Name Permit No. Refund Amt 08/21/2012 Starbucks Coffee EL12 -0758 $60.48 10/01/2012 August Residence EL12 -0836 $50.40 10/01/2012 Sports Authority EL12 -0839 $76.40 10/01/2012 Adame Residence EL12 -0691 $47.88 10/01/2012 JS Dental Clinic PG12 -140 $153.72 10/11/2012 Red Wing Shoes D12 -278 $178.80 10/24/2012 Interline Brand D12 -339 $306.95 I figure the one sent over on the 11th may have not made the check run based on its arrival time and I know the one sent over today didn't go through a time machine process, but am wondering about the others. Are they in process, do you need the paperwork sent to you again, etc.? Thanks! Jennifer 1 TO: FROM: DATE: SUBJECT: MEMORANDUM Laurie Anderson Brenda Holt 10/11/2012 Red Wing Shoes Permit Number D12 -278 Please draw a check in the amount of $178.80 (one hundred seventy -eight dollars and eighty cents) to be payable to SH2 Companies (attention Steve Hage) at 10914 181 Lane Northwest in Elk River, Minnesota 55330. This is a refund of part of the building permit fees paid. The applicant provided a contract for decreased value of tenant improvement work. The Building Official has approved a full refund of the permit fees overpaid based on this change in valuation. Please provide the refund as follows: Account 000.322.100 (NonRes Building): $178.80 Please forward the check to me and I will forward it on to the applicant. Thank you! Jennifer Marshall From: Steve Hage <steve.hage @sh2companies.com> Sent: Tuesday, October 02, 2012 2:07 PM To: Jennifer Marshall Subject: FW: Red Wing Shoe Permit Number Good Afternoon Jennifer, We had included the value of the racking in our original project valuation for the tenant improvement permit number D12 -278. If you could process a credit for the racking value of $12,000 we paid for under permit D12 -317 we would appreciate it. Re[sectfully, Steve Hage ComPameS 612- 817 -8024 steve. hageCcilsh2compan ies.com -Piz -Z78 C eEpto ts 5HoTt) 50, V, WA1 t // laGt)G, ci671I5 1,5cL _ 1 4 , 52.. 1-11631 01 s° p, cAt I; -* a 000 \ALLATtoN tA:1 to/E,---rr3gikAirfao ogul 1 SEPARATE PERMIT REQUIRED FOR: Mecanicat Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION FILE C PY Perm ft No., Va- Plan review approval Is subject to errors and omissions. Ap .,rcval of construction documents does not authorize fry: violation of any adopted code or ordinance. Receipt oi approved Field Copy and conditions is acknowledged: Date: City Of 1�kwila BUILDING DIVISION PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD Approved By:,eU .:. KID 11- Gate: X12- 9:$ 63% KMAit9 �0, kP'D111ot4 !tL AYPgD1►itl. SMOPS GENERAL SITE & BUILDING INFORMATION: OCCUPANCY GROUP: M- Mercantile CONSTRUCTION TYPE: III-B TENANT SPACE APPROX. 1,150 SF. - 1 1 1 - \ \111\\1 - 11111II11 11111111111 EX. HYDRANT LOCATION 1I1I 1,111 irrt'I'III IIIIII 111111 1111111111111111111 MAIM 0000 MO 111111111111 SOUTH CENTER PARKWAY KEY PLAN SCALE: NTS 25' -6" EX. HYDRANT LOCATION EX. DRY STANDPIPE Ci REGISTERED ARCt 'ECT ONALD P. SOCE ATE OF WASHI�'GTON. W a U 0 8spc /2114 W a 0 E 0 W U 0 VED FOIE MPL1AN OVED U 2012 H F. ikwila IVIISiIOt NEW INTERIOR HALL PARTITION 18' -O" gEX. DOOR EX. 0 DOOR 5' -0" EXISTING BATERY PACK EMERGENCY LIGHTING NEW OUTLET ABOVE STOREFRONT. VERIFY LOCATION IN FIELD EXISTING STOREFRONT 0 W 8' -O" NEW TRACK 0 LIGHTING SHOWROOM �, EQ. EQ. K C'S w 8' -O" LONG CHAIN HUNG FIXTURES 0 (I) STOCKROOM LIGHT TO BE ON NIGHT LIGHT CIRCUIT BATERY PACK EMERGENCY LIGHTING F STOCK ROOM NEW PENDANT LIGHTING ON NIGHT LIGHT CIRCUIT B /FIXTURE @1' -0" A.F.F. (TYP. 3) NEW CEILING FA NEW BATERY PACK I I EMERGENCY LIGHTING NEW EXIT I I SIGN NOTE: INSTALL OCCUPANCY SENSORS FOR LIGHTING IN STOCKROOMS REMOVE EXISTING WALL IN ITS ENTIRETY INCLUDING DOOR AND FRAME EX. DOOR EXISTING CABINETRY AND SINK TO REMAIN auxiewninixonwimmozoome NEW THIN BR CK or—NEIN TRACK VENEER TO LIGHTING 10' -0" A.F.F. O 0 0.0 0 O• 2' -6 " *- 6' -0" /1, 6' -0" FLOOR PLAN SCALE: 3/16" = I' -0" C EX. DOOR ILET RM. AS - 15 DATE: 01.31.2012 (I)DUPLEX OUTLET, (2)QUAD OUTET, DATA TV @ 8' -O" A.F.F. AND PHONE LINES I • • 10' 15' (2)QUAD OUTET ROUTER, DVR, PLAY, NETWORK, EMPTY CONDUIT, LOCATED ON SHELF ABOVE WORK BENCH. 8' -O" A.F.F. CITY LA AUG Z 0 2012 RMITCENIER PERMIT NEW FLOORING AND BASE SHEET -TITLE 21 ON Y NOTES & FINISHES PATCH AS REQUIRED AND PAINT ALL WALLS FROM 1. REMOVE EXISTING ACT THROUGHOUT SALES AND FLOOR TO CEILING FINISH AS INDICATED BY ROOM STOCK ROOM AREAS. PAINT EXPOSED CEILING. FINISH LISTED BELOW. COLOR; 'SHERWIN WILLIAMS' SW -11301 HERBAL WASH S .2. NEW INTERIOR WALL PARTITION CONSTRUCTION TO BE (FLAT) OR 'BENJAMIN MOORE' 2014 -040 DRY SAGE (FLAT). 3 -5/8" LIGHT GAGE METAL STUD m Ib" O.G. WITH 5/8" GYP BOARD TAPPED, SANDED AND PAINTED. EXTEND 8. REPLACE ALL LAY -IN FLUORESCENT LIGHT FIXTURES PARTION TO UNDERSIDE EXISTING CEILING. CONTINUE WITH T -8 FIXTURES. REPOSITION IN QUANTITY AND STUDS @ 48" O.C. TO UNDERSIDE OF EXISTING ROOF APPROXIMATE LOCATION AS SHOWN ON PLAN. DECK TO BRACE WALL. 'a. FLOOR FINISHES 3. REMOVE EXISTING FLOOR FINISHES INCLUDING - IN SHOWROOM; TO BE EARTHWORKS 1101 VCT. ADHESIVES THRO)GHT NEW SHOWROOM, STOCK ROOM, TOILET ROOM AREAS. PREP FLOOR AS NECESSARY - IN STOCK ROOM; TO BE ARMSTRONG IMPERIAL TEXTURE 12x12 CLASSIC WHITE. FOR VCT (CONCRETE LOOK T.B.D) SEAL EXISTING - IN TOILET ROOM; TO BE ARMSTRONG IMPERIAL CONCRETE FLOOR IN STOCK ROOM. TEXTURE 12x12 CLASSIC WHITE. 4. NEW DECORATIVE LIGHTING PROVIDED BY TENANT 10. PROVIDE BLACK VINYL BASE THROUGHOUT SPACE. INSTALLED AT 10' -0" A.F.F. II. ELECTRICAL, PLUMBING, AND HVAC HILL BE NDEREVIE 5. NEW DOORS TO BE SOLID CORE WOOD CLEAR STAINED WITH PAINTED METAL FRAME. SEPERATE PERMIT. CODE C APP b. REMOVE EXISTING SLATWALLS, BENCHES AND FURNITURE THRU -OUT SPACE. SEP Ci REGISTERED ARCt 'ECT ONALD P. SOCE ATE OF WASHI�'GTON. W a U 0 8spc /2114 W a 0 E 0 W U 0 VED FOIE MPL1AN OVED U 2012 H F. ikwila IVIISiIOt NEW INTERIOR HALL PARTITION 18' -O" gEX. DOOR EX. 0 DOOR 5' -0" EXISTING BATERY PACK EMERGENCY LIGHTING NEW OUTLET ABOVE STOREFRONT. VERIFY LOCATION IN FIELD EXISTING STOREFRONT 0 W 8' -O" NEW TRACK 0 LIGHTING SHOWROOM �, EQ. EQ. K C'S w 8' -O" LONG CHAIN HUNG FIXTURES 0 (I) STOCKROOM LIGHT TO BE ON NIGHT LIGHT CIRCUIT BATERY PACK EMERGENCY LIGHTING F STOCK ROOM NEW PENDANT LIGHTING ON NIGHT LIGHT CIRCUIT B /FIXTURE @1' -0" A.F.F. (TYP. 3) NEW CEILING FA NEW BATERY PACK I I EMERGENCY LIGHTING NEW EXIT I I SIGN NOTE: INSTALL OCCUPANCY SENSORS FOR LIGHTING IN STOCKROOMS REMOVE EXISTING WALL IN ITS ENTIRETY INCLUDING DOOR AND FRAME EX. DOOR EXISTING CABINETRY AND SINK TO REMAIN auxiewninixonwimmozoome NEW THIN BR CK or—NEIN TRACK VENEER TO LIGHTING 10' -0" A.F.F. O 0 0.0 0 O• 2' -6 " *- 6' -0" /1, 6' -0" FLOOR PLAN SCALE: 3/16" = I' -0" C EX. DOOR ILET RM. AS - 15 DATE: 01.31.2012 (I)DUPLEX OUTLET, (2)QUAD OUTET, DATA TV @ 8' -O" A.F.F. AND PHONE LINES I • • 10' 15' (2)QUAD OUTET ROUTER, DVR, PLAY, NETWORK, EMPTY CONDUIT, LOCATED ON SHELF ABOVE WORK BENCH. 8' -O" A.F.F. CITY LA AUG Z 0 2012 RMITCENIER PERMIT NEW FLOORING AND BASE SHEET -TITLE 21 ON Y 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 17135 Southcenter Parkway Date 8/17/2012 Tukwila, WA 98188 For Building Department Use et1 .. Ground Floor Applicant Name: 552 companies h*_ Applicant Address: 10914 181st LN NW Applicant Phone: Elk River, MN 55330 Project Description F. New Building fl Addition -_ Alteration r Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Prescriptive 0 Lighting Power Allowance O Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) [ No changes are being made to the lighting and space use not changed I Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area Ground Floor Retail Sales 1.33 1750 2328 Track Lights COD COIMPLIP NCE 21 • 1050 Ground Floor Pendant Lights APPROVED ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2328 Proposed Lighting Wattage Location (floor plan /room #) Fixture Descri ber of Watts! Fixture Watts Proposed ton REVIEWED FOR Fixtures Ground Floor Track Lights COD COIMPLIP NCE 21 50 1050 Ground Floor Pendant Lights APPROVED 3 60 180 Ground Floor Accent Lights V SEP 1 0 2012 4 42 168 Ground Floor Strip Flourescent E 15 32 480 City of Tukwila 6 BUILDING DIVISION Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1878 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lightin list the transformer rated wattage. R y D . 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. CITY 0 LA AUG 202012 PERMIT CENTER P122i ' 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage 0 Other Qualification Checklist Lighting C Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" andifixture Fixtures: Convention center answer is checked, the number of°f(xtures in the space is n,�o�t,limite by Code. Clearly (Section 1521) 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic indicate MI:Rd'spaces on plans. If not qualified, do LPA Calculations. 1.10 dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 0.90 Cafeterias, fast food establishment?, restaurants/bars' 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts Police and fire stations 0.90 3. LED lights. TABLE 15 -1 Unit Litahtinq Power Allowance (LPA Use' LPA` (W /ft`) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks churches)s 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishment?, restaurants/bars' 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail7', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility --1•.2077 - 'Mairtfliiorbliliding lobbies° (except mall concourses) 1.10 Museum 11.001U I : ;''11A 8 ! Gdrnriioh:areas? corridors, toilet facilities and I waShroofris, elovatar lobbies 0.80 Footnotes for Table 15 -1 ` VOSql A i 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be detem)ined by the buildingrofficia ,This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exeriSj areas. ; jr r 2) The watts per square foot may be increased, by 2% o'er foot of ceiling height above 20 feet, unless specifically directed otherwise by 3) Watts per square foot of room may be increased by 2-70 per foot of ceiling, height. above 12'feet. 4) For all other spaces, such as seating and common areas, use the; Ottlight Power. Allowance for assembly. 5) Watts per square foot of room may be increased by 24 per footiof'ceiling'helghtiabo ve.9 feet. 6) Reserved. 7) For conference rooms and offices less than 150fe with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 We. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major I I cire latio(t)paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1 „06 watts•for each separate tenant larger than 250 square feet in area. n ' ' The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of .track attachment). '• ` This, additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. subsequent footnotes. • N PERMIT COORD CORO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -278 PROJECT NAME: RED WING SHOES DATE: 08/20/12 SITE ADDRESS: 17135 SOUTHCENTER PY X__ Original Plan Submittal Response to. Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENT : B ing Division �9 1a. Fire Prevention Dtkm it Public Works Structural G oar its l Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 15t1 Comments: Incomplete n DUE DATE: 08/21/12 Not Applicable ❑ Permit Center Use only. ° .. .:2 INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 21. Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) n Notation: DUE DATE: 09/18/12 REVIEWER'S INITIALS: DATE: • !drink' Center. Use' Only • . • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Pifer Friendly Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MICHAEL JENSEN CONST LLC UBI No. 602745560 Phone 2533702800 Status Active Address 7205 Mcdonald Ave License No. MICHAJC934NM Suite /Apt. License Type Construction Contractor City Gig Harbor Effective Date 8/14/2007 State WA Expiration Date 8/23/2013 Zip 98335 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date JENSEN, MICHAEL ALAN Partner /Member 08/14/2007 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 748053C 08/14/2007 Until Cancelled $12,000.00 08/14/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Developers Surety & Indem Co B1S00013644 -01 08/14/2012 08/14/2013 $1,000,000.00 08/17/2012 4 No avigators Ins 46- 10149444 08/14/2011 08/14/2012 $1,000,000.0008 /12/2011 3 NAVIGATORS INS CO 4610122487 08/14/2010 08/14/2011 $1,000,000.00 08/09/2010 2 BANKERS INS 46044000079570108 /14/2008 08/14/2010 $1,000,000.00 08/04/2009 1 WESTERN WORLD INS CO NPP1121985 08/14/2007 08/14/2008 $1,000,000.00 08/14/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount PBER000374 9/28/2009 18.106.020 PLUMBER INFRACTION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2012