Loading...
HomeMy WebLinkAboutPermit D12-300 - H & R BLOCK - TENANT IMPROVEMENTH & R BLOCK 652 STRANDER BL D12 -300 City otTukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0005800037 Address: 652 STRANDER BL TUKW Suite No: Project Name: H & R BLOCK DEVELOPMENT PERMIT Permit Number: D12-300 Issue Date: 10/15/2012 Permit Expires On: 04/13/2013 Owner: Name: BC PARTNERS LLC Address: C/0 MK PROPERTY SVC LLC , PO BOX 997 98065 Contact Person: Name: CHUCK LINDBERG Address: 12920 SE 95 WY , NEWCASTLE WA 98056 Contractor: Name: ENRICHED DESIGNS INC Address: 12920 SE 95TH WAY , NEWCASTLE WA 98056 Contractor License No: ENRICDI12809 Lender: Name: SELF FUNDED - H & R BLOCK Address: Phone: 425 - 255 -5467 Phone: 425 - 255 -5467 Expiration Date: 07/03/2013 DESCRIPTION OF WORK: NEW TENANT: INTERIOR TENANT IMPROVEMENT TO EXISTING VACANT SPACE TO CREATE OFFICES FOR A TAX PREPARATION TENANT. Prior to Public Works Final - Applicant shall submit for a Public Works Permit to install an approved Fire Backflow Device (DCDVA) within an approved Fire Vault (or) provide a Performance Bond in the amount of 150% x cost of the work and state when the work will be completed. Value of Construction: $51,000.00 Fees Collected: $1,601.21 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D12 -300 Printed: 10 -15 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: 475/7_2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: �LGC �i�li Date: / 7S �� This permit shall become null and void if the wo(k is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: AU permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D12-300 Printed: 10 -15 -2012 7: All construction shall be done in conforri e ;; e with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC doc: IBC -7/10 D12 -300 Printed: 10 -15 -2012 1008.1.8.1) 25: Exit hardware and marking shall meet the equirements of the International Fire Code. (Chapter 10) 26: .Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall continence without approved drawings. (City Ordinance No. 2327). 30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2328) 31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 36: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 37: Contractor shall notify Public Works Project Inspector Mr. Dave Stuckle at (206)433 -0179 of commencement and completion of work at least 24 hours in advance. 38: Prior to Public Works Final - Applicant shall submit for a Public Works Permit to install an approved Fire Backflow Device (DCDVA) within an approved Fire Vault (or) provide a Performance Bond in the amount of 150% x cost of the work and state when the work will be completed. doc: IBC -7/10 D12 -300 Printed: 10 -15 -2012 CITY OF TUKWA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila; WA 98188 http: / /-www.TukwilaWA.gov Building Permit • No. h i > _ go0 • • Project No. Date Application Accepted: ' 7774. • Date Application • Expires: 71"7) (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review: Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 000580 -0037 Site Address: 652 Strander Boulevard; Tukwila, WA Suite Number: Floor: New Tenant: 0 Yes Tenant Name: H &R Block PROPERTY OWNER • - Name: BC Ptnrs LLC c/o MI{ Property Svcs Address: 8124 Falls Ave SE City: Snoqualmie State: WA Zip: 98065 .CONTACT, PERSON — person receiving all project . • communication• • Name: Chuck Lindberg (EDI) Address: 12920 SE 95th Way Address: Phone: (425) 255 -5467 Fax: City: State: Zip: Phone: (425) 255 -5467 Fax: Email: GENERAL CONTRACTOR INFORMATION Company Name: Enriched Design Inc:, (EDI) Address: 12920 SE 95th Way City: Newcastle State: WA Zip: 98056 Phone: (425) 255 -5467 Fax: Contr Reg No.• Exp Date: 7 3' / 3 eNRIcD!!2koci Tukwila Business License No.: BiAS 0 i06 s3 H:\Applications \Forms - Applications On Line•.2011 Applications \Permit Application Revised = 8- 9- 11.docx Revised: August 2011 bh 0 ARCHITECT OF RECORD • Company Name: urban solutions studio, LLC Architect Name: Gary B: Barber, AIA Address: 1555 Union Ave NE, #66 City: Renton State: WA Zip: 98059 Phone: (425) 922 -1474 Fax: Email: gary. barber @urbansolutionsstudio:com ENGINEER OF RECORD Name: /t vc 1e g/e.ci • Company Name: N/A Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: /t vc 1e g/e.ci Address: • c % �5 a Sri -�.✓d� �v Cityr- /4_ State: it)Gi Zipy /1Y Page 1 of4 BUILDING PERMIT INFORMATIONS 06- 431 -3670 Valuation of Project (contractor's bid price): $ 51,000 Describe the scope of work (please provide detailed information): Interior tenant improvement to an existing vacant storefront space to create offices for a tax preparation tenant. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Z No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes iii No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. F1AApplicat ions \Forms-Applications On Line \2011 Applications`,Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la` Ftaor 2,165 2,165 V- Sprinkler M 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Z No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes iii No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. F1AApplicat ions \Forms-Applications On Line \2011 Applications`,Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction In all cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED 1'O APPLY FOR THIS PERMIT. BUILDING 0 R OR AUTH Il RIZ_ D AGENT: Signature Il Print Name :_��,�j,�. Mailing Address: / 9 O SG- 7—C 7P) HAApplications \Forms - Applications On Linc \201 I Applicaiions\Permit Application Revised - 8-9 -11 docx Revised: August 2011 hh Date. q- 7-- Day Telephone: _ itieg,r_Af /4 � . 98 L$Z City State Zip Page 4 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0005800037 Address: 652 STRANDER BL TUKW Suite No: Applicant: H & R BLOCK RECEIPT Permit Number: D12-300 Status: PENDING Applied Date: 09/07/2012 Issue Date: Receipt No.: R12 -02555 Payment Amount: $1,601.21 Initials: WER Payment Date: 09/07/2012 03:17 PM User ID: 1655 Balance: $0.00 Payee: CHARLES LINDBERG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 717061 ACCOUNT ITEM LIST: Description 1,601.21 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,601.21 967.70 629.01 4.50 doe: Receipt -06 Printed: 09 -07 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit.lnspection Request Line (206) 431 -2451 D 12. -3oa • Project: Type nspection: Address: 1 7..- ,S tAv' . Date Called: Special Instructions: (pS 1 __/'2 —a (* Date Wanted : I — 6 ~(_ m P•m. Requester: Phones No ,-4 Jq y (145 (.Approved per applicable codes. D Corrections required prior to approval. COMMENTS: r Inspee D 4.4AA.L7 'It EIIIISPECTION FEE REQ IRED. Pr or to al at 6300 Southcenter Blvd., Suite 100. Date: -10 -13 next inspection. fee must be Call to schedule reinspection. 4j INSPECTION NO. INSPECTION RECORD Retain a copy with permit D12-306 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: H e 2 II. LOCe Type of Inspection: RI 14 Ai, (I) (6 L4z/Ax, - /PAPA ' Address: (,S2. 5 ► aet.113 J? Date Called: / /A A/ 6r'3i1('m r4£c/.7r.,/A1 /es , '5) % ,,?p°' ' of,-/ 7)te # ?fM'J' y /�ii,a/4Vfral Special Instructions: C A;! A t4? A 3 Ot, 30 a ( 1 6O -0 I Date Wanted: . 't z �a phi Requester: Phone No: 2660'145c -II q C Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p Al (I) (6 L4z/Ax, - /PAPA ' i j �rr7i f (ii f f1' l4,V 2is / //� /'' AJfr l S / /A A/ 6r'3i1('m r4£c/.7r.,/A1 /es , '5) % ,,?p°' ' of,-/ 7)te # ?fM'J' y /�ii,a/4Vfral 30 Day S !! •: - .1 , (EINSPECTION F REQUIRED. Prior to next inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call t6 schedule reinspection. Date: /13/a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: (-t fi 2 ir6 10C i_ Type of Inspection: , Z) . 5 pc,J bc 1 (jY , t~ ii.J 4 Address: Cp SZ s, 12 A0 c4 t Date Called: . /.v-.‹.:„^ Special Instructions: Date Wanted:. jU -z6- l?.._ a.m. p.m. Requester: Phone No: Approved per applicable codes. Il Corrections required prior to approval. COMMENTS: 6 l '''..s 1. ., P g ke(i' eve; ):4,•( - . /.v-.‹.:„^ '7) I.JR' f :.jsc.Cn -t,. - lap eA--er,c, I 's fir: Date: EINSPECTION FE F) REQUIRED. ffrior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD • Retain a copy with permit INSPECTION NO. . • • PERMIT NO. CITY OF TUKWILA BUILDING 'DIVI:SION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 W\P-' Project: 1-x P fl. a Lod. Type of Inspection: I: ft g wI G Address: 1.:7)<-) 7 d Z AI. sjoG2 Date Called: • Special Instructions: Date Wanted:. 1 0 - % ‘ a.m., p.m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: nspec r: p Date: E SPECTION FEE REQ .IRED. Pr) • r to next inspOtiori.'fee.must be d at 6300 Southcenter lvd.. Suite 100. Call to sd►edute Treinspection. • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 • v,(L- ",‘ Project � � � \o`� Type of Inspection: Sprinklers: " e Address: �5Z QNO Contact Person: . Suite #: 'cc., .121 Special Instructions: Permits: t --\otyE- Phone No.: q4.Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: `i Date: \■\ tz,\ \ Z__ Sprinklers: " e Fire Alarm: tyeN* • Hood & Duct: to 0 Monitor: Pre -Fire: Permits: t --\otyE- Occupancy Type:•_ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: 1 Company Name: City: 1 State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Date: \■\ tz,\ \ Z__ Hrs.::\ ,)4 Inspector: ;- M5 \ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: 1 Company Name: City: 1 State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Po- 3Do o- s- /9? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Proj ci: /t rt'� bbck Type of Inspection: 5 ra, L cc v-ck . Address: -- Suite Suite #: Contact Person: Special Instructions: Phone No.: $ . pproved per applicable codes. Corrections required prior to approval. COMMENTS: SO coc/ev Needs Shift Inspection: Date:"',h? s/ Z .sprinklers :.• ,, f : i, Fire Alarm: { Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: C a" • Date:"',h? s/ Z Hrs.: v $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential rofect Summary J -S 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 652 Strander Blvd Date 9/7/2012 Tukwila, WA 98188 For Building Department Use Applicant Name: EDI Applicant Address: 12920 S.E. 95th Way, Renton, WA 98056 Applicant Phone: (206) 255 -5467 p« -3 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2012 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 7 2012 PERMIT CENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior hting.S.ummary.. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 652 Strander Blvd Date 9/7/2012 Tukwila, WA 98188 For Building Department Use All other areas Applicant Name: Eoi Applicant Address: 12920 S.E. 95th Way, Renton, WA 98056 Applicant Phone: (206) 255 -5467 Project Description Office • New Building • Addition 74 Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 10 not changed • No changes are being made to the lighting and space use 7A Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan/room #) Occupancy Description Allowed Watts per ft2 ** cross intenor Area in ft2 Allowed x Area All other areas Office Space 0.92 2165 1992 Office 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w -T8 1 67 67 Open Office 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - 25w-T8 . 10 81 810 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1992 Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Lobby /Waiting 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 2 67 134 Office 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w -T8 1 67 67 Open Office 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - 25w-T8 . 10 81 810 Office 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 . 2 67 134 Office 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 . 2 67 134 Office 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 2 67 134 Hall 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 1 67 67 Toilet Wall- mounted fixtures w/ 1 fluor. Lamp 1 41 41 Toilet Wall- mounted fixtures w/ 1 fluor. Lamp 1 41 41 Break Room 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 . 2 67 134 File Storage 2' x 4' Fluor. fixtures (exist. refitted w/ 2 - 25w-T8 4 67 268 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1964 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp two (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential ght'ng Summary (back) Iriterior , 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential G -I Revised December 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage • Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 'i Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA'2 (W /ft`) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified iaborator" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies3 (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 ootnotes for f able 1b- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories!, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. - 2009 Washington State r�Code Compliance Form for Nonresidential and Multifamil Lighting, Motor and Transformer Permit Plans Checklist LTG `CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 652 strander Blvd Date 9/7/2012 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) N.A. 1513.1 Local control /access Schedule with type, indicate locations Ye3 1513.2 Area controls Maximum limit per switch No 1513.3 Daylight zone control Schedule with type and features, indicate locations No vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans No 1513.4 Display /exhib /special Indicate separate controls N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timer w/backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations No 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans No 1513.7 HoteVmotel controls Indicate location of room master controls No 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) 1514 IMax. watts 'Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) N.A. I 1540 'Transformers 'Indicate size and efficiency I If "no" is circled for any question, provide explanation: 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential er . owance4:' ustments 2009 Washington Sta e Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address 1652 Stranger Blvd Revised December 2010 1 Date 9/7/2012 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances fo interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior Location (floor plan/room #) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 Lobby /Waiting 0.91 9.5 feet 9 feet 0.92 Office 0.91 9.5 feet 9 feet 0.92 Open Office 0.91 9.5 feet 9 feet 0.92 Office 0.91 9.5 feet 9 feet 0.92 Office 1.10 9.5 feet 9 feet 1.11 Office 0.91 9.5 feet 9 feet 0.92 Hall 0.91 9.5 feet 9 feet 0.92 Toilet 0.91 9.5 feet 9 feet 0.92 Toilet 0.91 9.5 feet 9 feet 0.92 Break Room 0.91 9.5 feet 9 feet 0.92 File Storage 0.91 9.5 feet 9 feet 0.92 rom Table 15 -1 based on exceptions listed in footnotes 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential xte,ri kghling uymary • 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Proj Addres 652 Strander Blvd Date 9/7/2012 Tukwila, WA 98188 For Building Department Use Area (ft2), perimeter (If) or # of items Name: Eni Appl. Name 12920 S.E. 95th Way, Renton, WA 98056 Appl. Phone (206) 255 -5467 Project Description • New ■ Addition 'i Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Lighting Zone (as specified by Jurisdiction) o Zone 1 Zone 2 0 Zone 3 0 Zone 4 Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires> 100 Watts) motion sensor • Efficacy> 60 lumens/VV • Controlled by • Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) and space use not changed. 'A No changes are being made to the lighting • Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Description Hnowea watts per ft2 or per If Area (ft`), perimeter (If) or # of items Hnowea vvans x ft2 (or x If) Main Entry Select Zone Total Allowed Tradable Watts: raaabie 1'roposeci Ligllting Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total proposed tradable watts may not exceed the sum of total allowed tradable watts Total Proposed Tradable Watts: plus the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: Fixture Description Non - Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non - tradable surfaces are less than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: erg,. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential ightng Summary:(bac 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised December 2010 Specific area description Zone 1 500 W Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' Tradable Surfaces 2 Uncovered Parking Parking lots and drives Areas 0.04 W /ft2 0.06 W /ft2 0.10 W /ft2 0.13 W /ft2 Building Grounds Walkways less than 10 ft wide 0.7 W /linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W /ft2 0.14 W /ft2 0.16 W /ft2 0.2 W /ft2 Exterior Stairways 0.75 W /ft2 1.0 W /ft2 1.0 W /ft2 1.0 W /ft2 Pedestrian tunnel 0.15 W /ft2 0.15 W /ft2 0.2 W /ft2 0.3 W /ft2 Landscaping 0.04 W /ft2 0.05 W /ft2 0.05 W /ft2 0.05 W /ft2 Building Entrances and Exits Main entries 20 W/linear foot of door width 20 W/linear foot of door width 30 W /linear foot of door width 30 W/linear foot of door width Other doors 20 W /linear foot of door width 20 W/linear foot of door width 20 W /linear foot of door width 20 W /linear foot of door width Entry canopies 0.25 W /ft2 0.25 W/ft2 0.4 W /ft2 0.4 W /ft2 Sales Canopies Free standing and attached 0.6 W /ft2 0.6 W /ft2 0.8 W /ft2 1.0 W /ft2 Outdoor Sales Open areas3 0.25 W /ft2 0.25 W /ft2 0.5 W /ft2 0.7 W/ft2 Street frontage for vehicle sales lots in addition to "open area allowance No Allowance 10 W/linear foot 10 W /linear foot 30 W /linear foot Non - Tradable Surfaces° Building Facades No Allowance 0.1 W /ft2 for each illuminated wall or surfaces 0.15 W /ft2 for each illuminated wall or surface6 0.2 W /ft2 for each illuminated wall or surface Automated teller machines and night depositories 270 W per locations _locations 270 W per 270 W per locati o n8 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W /ft2 of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft2 of covered & uncovered area Material handling and associated storage No Allowance) No Allowance No Allowance 0.5 W /ft2 Drive -up Windows & Doors 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry FOOTNOTES FOR TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales lots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length. 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. • David McPherson From: Syd Severe <Syd @mkps.net> Sent: Friday, October 05, 2012 4:17 PM To: David McPherson Cc: Chuck Lindberg Subject: RE: H & R Block at 652 Strander Boulevard - D12 -300 Importance: High Hi David — Per our conversation and the information you sent to me please let this serve as written confirmation that we are going to fix /replace the backflow device as needed and required just as soon as possible but no later than by the end of the year. I am currently working with Jim Turk at Fire Systems West who can be reached at 253 - 229 -9959 if you need further details / clarification on what we are going to do to bring that vault to code. He is working on the plan and pricing and will get that to me as soon as he can so we can move forward with the work. Please let me know if you have any questions /further comments. Warmest Regards, Syd A. Scvcrc MK Property Services, LLC Property Management & Leasing PO Box 997 Snoqualmic, WA 98065 425 - 495 -1353 Cell 425 - 888 -2993 Office syd @mkps.nct From: David McPherson f mailto: David .McPhersonCahTukwilaWA.govl Sent: Tuesday, October 02, 2012 4:16 PM To: Syd Severe Subject: H & R Block at 652 Strander Boulevard - D12 -300 Syd, Ref. H & R Block at 652 Strander Boulevard - D12 -300 (Fire Backflow). Please see attached for your information and use. Let me know if you have questions /comments. Thank you. Dave David McPherson Development Engineer City of Tukwila 6300 Southcenter Blvd #100 Tukwila, WA 98188 1 • a ph: (206) 431 -2448 1 fx: (206) 431 -3665 David.McPherson@TukwilaWA.gov 1 www.tukwilawa.gov * *NEW EMAIL ADDRESS AND WEB ADDRESS! ** • • October 2, 2012 Building at 642 Strander Blvd — Building Permit no. D12 -300 The following comment was received from — Han Kirkland City of Tukwila — Public Works Maintenance 600 Minkler Blvd. Tukwila, WA 98188 (206) 433 -1860 Han.kirkland @tukwilawa.gov / www.tukwila.gov Existing 8 -inch fire backflow device failed testing. Tester's comments: Couldn't test assembly #1 shut off valve which is a PIV — would not shut. Not an approved assembly. Could use three (3) new .75" test cock valves. NOTE: If you opt to install, you may install under a separate permit or under a revision to Building Permit no. D12 -300. If you opt to install under the Building permit, you must supply the installation plans consisting of a schematic that clearly shows the location of the fireline and fire backflow device in relationship to the property line(s) and the building; together with a construction cost estimate to the Permit Center as a revision to the Building permit. A (DCDVA) installation will trigger a Public Works Type `C' Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for installation of the subject device) when a revision to this Building permit is submitted. An additional 2.5% of construction cost for backflow installation will be assessed at the time of permit revision issuance. If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150% of the design and installation cost, and 3) a letter stating your intent to install the backflow device by a certain date. This must be done before the Permit Center issues the permit. Feel free to contact me (or) call Mike Cusick, Public Works Senior Water and Sewer Engineer, at (206) 431 -2441 if you have any questions /comments. David H. McPherson Development Engineer, City of Tukwila 6300 Southcenter Blvd #100 Tukwila, WA 98188 ph: (206) 431 -2448 I fx: (206) 431 -3665 David.McPherson@TukwilaWA.govIwww.tukwilawa.gov Page 1 of 1 • City of f 7'111Cw11ci • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 20, 2012 Chuck Lindberg Enriched Design Inc. 12920 SE 95 Wy Newcastle, WA 98056 RE: Correction Letter #1 Development Permit Application Number D12 -300 H &R Block - 652 Strander BI Dear Mr. Lindberg, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. At this time the Fire and Planning Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Public Works Department: David McPherson at 203 431 -2448 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431 -3670. Sincerely, en File No. D12 -299 W:\Permit Center\ Correction Letters \2012012-300 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 4 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: September 14, 2012 Project Name: H &R Block Permit #: D12 -300 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The cover sheet refers to this as an "M" occupancy. Revise to indicate "B" occupancy. Include the number of occupants for this space on the cover sheet. (IBC 304.1 & TABLE 1004.1.1) 2. The plan shows new office spaces created however a way to provide ventilation or air - conditioned ventilation has not been identified for the new spaces. Please provide a plan that shows any alterations to the mechanical ventilation that may be necessary for the new office layout. Interior spaces intended for human occupancy shall be provided with active or passive space- heating systems capable of maintaining a minimum indoor temperature of 68.F at a point 3 feet above the floor on the design heating day. Mechanical alterations or new system components shall require a separate mechanical permit. (IBC 1204.1, IMC 401.22 & 401.3) 3. Specify the new walls or furred out walls separating the heated space from non - heated spaces or exterior walls, to be provided with R -21 insulation. If insulation exists, please indicate on the plan in the "wall type key." Specify any un- heated spaces if applicable. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PUBLIC WORKS DEPARTMENT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: September 19, 2012 PROJECT: H & R Block Building Permit @ 652 Strander Boulevard PERMIT NO: D12 -300 PLAN REVIEWER: Contact David McPherson, Development Engineer (206) 431 -2448, if you have any questions regarding the following comments. David.McPherson @TukwilaWA.gov 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The City has determined that the H & R Block building has deficiencies on domestic water service, landscape irrigation, and fire prevention requiring the following upgrades. a) Domestic Water Service The existing 1.5 -inch domestic backflow prevention device, Reduced Pressure Principle Assembly (RPPA), test is not current. Submit a current test report to the Public Works Department. b) Landscape Irrigation The existing 1.5 -inch irrigation backflow prevention device (DCVA) test is not current. Submit a current test report to the Public Works Department. c) Fire Prevention The existing 8 -inch fire line backflow prevention device (DCDVA) test is not current. Submit a current test report to the Public Works Department. The Public Works Director will withhold issuance of Building Permit no. D12 -300 until a copy of the backflow test reports for the above items (a), (b) and (c) are received by Public Works. A separate letter was mailed to the Property Owner — BC Partners LLC, C/O MK Property Services, 8124 Falls Ave. SE, Snoqualmie, WA 98065. Feel free to contact me (or) call Mike Cusick, P.E., Public Works Senior Water and Sanitary Sewer Engineer at (206) 431 -2441, if you have questions /comments. • • David McPherson From: Joanna Spencer Sent: Wednesday, September 19, 2012 10:53 AM To: David McPherson Subject: FW: H &R block TI @ 652 Strander FYI, Joanna From: Todd Reedy Sent: Thursday, September 13, 2012 1:39 PM To: Joanna Spencer Subject: RE: H &R block 11 @ 652 Strander Hi Joanna, Regarding the 11 at 652 Strander: -1.5" RPPA on domestic service is overdue for testing, was due last April. -1.5" irrigation DCVA is overdue for testing, was due last April. -8" fireline DCVA is very overdue for testing. The assembly failed testing in April 2009 and we have not received a test report since then. They get notified about the testing requirement every year in April. Hope you're having a great day, Todd From: Han Kirkland Sent: Thursday, September 13, 2012 9:54 AM To: Todd Reedy Subject: FW: H &R block 11 @ 652 Strander HAHAHAHAAHAHHA! ® From: Joanna Spencer Sent: Thursday, September 13, 2012 9:46 AM To: Bryan Still Cc: Han Kirkland; David McPherson Subject: FW: H &R block 11 @ 652 Strander Subject: H &R block 11 @ 652 Strander Hello Bryan, Are they current on their backflows ? Tha nks, Joanna Phone: (206)431 -2440 Fax: (206)431 -3665 Joanna.Spencer @TukwilaWa.gov /www.TukwilaWa.gov 1 stERMIT COORD C'� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -300 PROJECT NAME: H & R BLOCK SITE ADDRESS: 652 STRANDER BL DATE: 10/04/12 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTME TS* B i ing Division D ∎' /pG icflO.�� Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/09/12 Complete qi Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route )0 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/06/12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D12 -300 DATE: 09 -07 -12 PROJECT NAME: .H & R BLOCK SITE ADDRESS: 652 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPA T ENTS: ul ding ivision, Ft 41041 is Firt a Predehtion Structural AV A- 9-11 -1 2 Planning Division ❑ Permit Coordinator gi DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete sp Incomplete DUE DATE: 09 -11 -12 Not Applicable Comments: •Permit Center 'Only" • .. :. • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10 -09 -12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) tXi Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only. . : CORRECTION LETTER MAILED: O°1 wu % Departments issued corrections: Bldg Fire ❑ Ping ❑ PW Documents/routing slip.doc 2 -28 -02 Staff Initials:��r -- r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Re► ,%sions will not be accepted through the mail, fax, etc. Date: 1/a))11- Plan Check/Permit Number: D12-300 Response to Incomplete Letter # Response to Correction Letter # 1 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: H &R Block OCT 0 42012 PERMIT C R Project Address: 652 Strander B1 Summary of Revision: rip -% 0 = APPlif Contact Person: Pg*llou/417 (4441t4IH7l! r ,dcbt7YD NP ust4oz.. ALL, GUes� a 0 -- Sheet Number(s): d "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: , Entered in Permits Plus on \applications\forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople liter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ENRICHED DESIGNS INC UBI No. 601070096 Phone 4252555467 Status Active Address 12920 Se 95Th Way License No. ENRICDI12809 Suite /Apt. License Type Construction Contractor City Newcastle Effective Date 9/29/1988 State WA Expiration Date 7/3/2013 Zip 98056 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date LINDBERG, CHARLES C President 06/15/2011 Amount LINGBERG, PENNY J President 09/29/1988 06/15/2011 YANTZER - TRISTA, KAREN Secretary 09/29/1988 06/15/2011 LINDBERG, NIKKI L Secretary 01/01/1980 06/15/2011 LINDBERG, CHARLES C Vice President 09/29/1988 06/15/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 TRAVELERS CAS Et SURETY CO 103490911 07/01/2005 Until Cancelled $12,000.00 06/02/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 Maxum Indemnity Co BDG0059814 02/08/2012 02/08/2013 $1,000,000.0001 /30/2012 14 MAXUM INDEMNITY CO BDG0059813 02/08/2011 02/08/2012 $1,000,000.0001 /03/2011 13 MAXUM INDEMNITY CO BDG00059812 02/08/2007 02/08/2011 $1,000,000.00 01/06/2010 12 MAXUM INDEMNITY COMPANY BDG000598102 02/08/2005 02/08/2007 $1,000,000.00 01 /11/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 10/15/2012 PROJECT GENERAL NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE WORK IS COMPLETED. 2. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES DURING THE COURSE OF THIS PROJECT. 3. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASSES, SMOKE, VIBRATION, HAZARDOUS CONDITIONS OR OTHER SUCH CAUSES. 4. THE CONTRACTOR SHALL SECURE ALL SUCH INSPECTIONS AND FINAL APPROVALS FROM THE FIRE DEPARTMENT PRIOR TO OCCUPANCY. 5. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. COMMENCEMENT OF THE WORK CONSITUTES ACCEPTANCE OF EXISTING CONDITIONS AS ADEQUATE FOR THE PROPER COMPLETION OF THE WORK DETAILED HEREIN. 6. EXISTING DETAILS, ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCMENT OF WORK. IF CONDITIONS OR DETAILS DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY SO THAT APPROPRIATE MODIFICATIONS CAN BE MADE BEFORE PROCEEDING. 7. THERE SHALL BE NO DEVIATIONS FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD URBAN SOLUTIONS STUDIO, LLC AND THE ARCHITECT HARMLESS FOR ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 8. THE APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMAN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES, WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 9. SEE STRUCTRUAL NOTES REGARDING LUMBER GRADES, NAILING, MISCELLANEOUS STRUCTURAL STEEL, GROUTING AND ATTACHMENTS. 10. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. 11. ALL DIMENSIONAS ARE TO THE CENTERLINE OF COLUMN, FACE OF STUD, CENTERLINE OF STUD OR FACE OF CMU - UNLESS OTHERWISE NOTED. 12. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME FOR OTHER SIMILAR WORK. 13. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OF WRITTEN DIRECTIONS. 14. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATION WITH FIRE MARSHALL. FIRE EXTINGUISHER LOCATIONS SHALL NOT BE BLOCKED OR HIDDEN BY PRODUCT DISPLAYS, DECOR FIXTURES OR ANY SUCH SIMILAR MATERIALS. 15. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 16. EXIT DOORS, EXIT LIGHTS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL, DECOR CR FURNISHINGS. 17. FINISH FLOOR, TOP OF CONCRETE SLAB, DATUM = +0.00'. 18. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE - TREATED. 19. REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS OF LIGHTING FIXTURES AND CEILING MATERIALS SHOULD BE CONFIRMED PRIOR TO INSTALLATION. 20. PROVIDE SEISMIC BRACING AT ALL SUSPENDED ACOUSTICAL CEILING AREAS @ 12' O.C. IN BOTH DIRECTIONS. 21. THE CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR ROUGH OPENING REQUIREMENTS WITH DOOR AND WINDOW MANUFACTURERS PRIOR TO INSTALLATION. 22. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS AND ROOF AND OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND DOORS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED. GASKETED OR WEATHER- STRIPPED TO LIMIT AIR LEAKAGE AND PROHIBIT WATER PENETRATION. 23. ALL TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH MANUFACTURER - APPROVED METHODS. 24. PLUMBING, ELECTRICAL AND HVAC SYSTEMS ARE BIDDER - DESIGNED AND COVERED UNDER SEPARATE PERMIT. CONTRACTOR SHALL SUBMIT BIDDER - DESIGN DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION AND INSTALLATION. SITE DATA: PROJECT ADDRESS: CURRENT ZONING: PARCEL NUMBER: PROJECT TEAM: BUILDING OWNER: TENANT: ARCHITECTURAL: GENERAL CONTRACTOR: WORK DESCRIPTION: OCCUPANCY CONSTRUCTION TYPE PARKING PROVIDED VALUATION OF WORK. 644 STRANDER BLVD. TUKWILA WA 98188 TUC (CITY OF TUKWILA) 000580 -0037 BC PARTNERS LLC C/O MK PROPERTY SERVICES SNOQUALMIE, WA 98065 425 - 888 -2993 H &R BLOCK urban solutions studio, IIc 1555 UNION AVE NE, #66 RENTON WA 98059 425- 922 -1474 CONTACT: GARY B. BARBER, AIA gary. barber @urbansolutionsstudio.com EDI 12920 S.E. 95th Way NEWCASTLE WA 98056 425 - 255 -5467 CONTACT: CHUCK LINDBERG INTERIOR TENANT IMPROVMENT TO EXISTING VACANT 2,165 S.F. STOREFRONT SPACE. NO EXTERIOR MODIFICATIONS TO THE BUILDING SHELL ARE PLANNED UNDER THIS SUBMITTAL. SIGN PERMIT WILL BE UNDER A SEPARATE SUBMITTAL. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical C Plumbing ZGas Piping City of Tukwila BUILDING DIVISION SPRINKLERED EXISTING PARKING UNCHANGED $ 51,000 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25 -23 -04 -BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HWY ENGR STA 160 +00 TH FR SD POB ALG SD WLY RNV LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -07 -31 W 35 FT FR C/L AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON NLY RNV LN OF STRANDER BLVD TH ALG SD NLY RNV LN TANGENT TO PRECEDING CURVE S 81 -07 -31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19 -33 -22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L RNV 30 FT WIDE TH ALG SD SLY LNS S 87 -12-48 E 194.01 FT TAP ON WLY R/W LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08 -52 -29 E 165.06 FT TO POB SHEET INDEX: A -1 COVER SHEET A -2 FLOOR PLAN A -3 REFLECTED CEILING PLAN TO 1 -90 sivIsiow No changes sh I be made to the scope of work without prior approval of Tukwi4a Building Division. t;OTZ: Revisions will ittqvire a new plan submittc:i used may in;,udo additional plan review fees. NTERURBAN VE S �GRP S RENTON SOUTHCENTER BLVD VICINITY MAP SCALE: 1" -1 000'-0" 0 500' 1000' NORTH ROPERTY LINES SITE PLAN r 3 , en re . 'ew approval is suIect teverrors and omiss ns. T. Nova ovia of constrtictior tbCUme141033 z 111 viola ' n of any adopted code or ordinance.feceipt w a pro =d F •py and is acknowledged: J Q s... « N , :s : •/A -/C--1.2--- ill City Of Tilrkwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2012 City o T i!a BUILDIN !VISION FXLE COPY eft No. 1) 12 -OQ RECEIVED OCT U 2012 TUKWILA NURUO WORKS STRANDER BLVD SCALE: 1" = 40' -0" 0 20' 40' CORRECTOR RII 12- NORTH r -1 L J ( 0 0 Cr) co O Cl 0 w 0 w z w a z 0 z 0 U 0 a 1- z 0 H J 0 z m V) J Z< Qcsi U ° U Z o °Id SaZ zO =UNIO H H = Z w w wce N00a �o ww W . I- }0LL< �EZUO ▪ paw o�a= -I LIJ Q¢ aH te w O Ln NOww D Z a m = U w aZ° 0 Owl m j >Mw HNLn V) Z Z Z w Q w OOUQ I- Z})72� yyaU ZOO V)Z CC mu~, w OU a Z w =��oN H z L.n w N L11 ko � M U ic) a o z o m Q -J ca U 1 ry LL F- N Y IA- F- =o AN INTERIOR TENANT IMPROVMENT TO AN EXISTING 2,165 S.F. SPACE w w v7 W W 2 (n oc w 0 U tKS BY f SUBMITTAL - 4` a i PLEASE CONSIDER THE ENVIRONMENT l BEFORE PRINTING THIS DRAWING 11 t . . C; 1 1 1 DRAWN BY: GBB RECttvru CITY OF TI lKWIIA. OCT 0Li 2012 PERMIT CENTER JOB #: DATE/i5- `I_ 9/5/12 SHEET #: A1.0 L J DOOR SCHEDULE DOOR FRAME SIZE MAT'L. MAT'L. FINISH NEW/ EXIST'G. HARDWARE NOTES 1 3/0 X 7/0 STOREFRONT ALUM. ALUM. FACT. (E) EXIST'G. EXIST'G. 2 3/0 X 7/0 FLUSH STEEL STEEL PAINT (E) EXIST'G. EXIST'G. 3 3/0 X 7/0 FLUSH SC WD. EXIST'G. STAIN (E) EXIST'G. EXIST'G. 4 3/0 X 7/0 FLUSH SC WD. EXIST'G. STAIN (E) EXIST'G. EXIST'G. 5 10/0 X 9/0 OVERHEAD STEEL STEEL FACT. (E) EXIST'G. EXIST'G. 6 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 7 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 8 3/0 X 7/0 FLUSH SC WD. WOOD STAI N NEW GROUP 1 9 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 10 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 2 11 3/0 X 7/0 FLUSH HARDWARE GROUPS: GROUP 1 1 1/2 PAIR BUTTS PRIVACY LATCHSET (LEVER -TYPE) SILENCERS GROUP 2 1 1/2 PAIR BUTTS PASSAGE LATCHSET SILENCERS SC WD. WOOD STAI N NEW GROUP 3 GROUP 3 1 1/2 PAIR BUTTS PASSAGE LATCHSET OVERHEAD CLOSER SILENCERS DEADBOLT NOTES KEY: 1O DOOR TO BE ABANDONED IN PLACE - GC TO SECURE DOOR FROM THE INTERIOR AND FILL ANY GAPS TO ENSURE WEATHER- TIGHTNESS OF BUILDING ENVELOPE. EXISTING TOILET ROOMS TO REMAIN - CLEAN AND PAINT WALLS ONLY NO ALTERATIONS WALL TYPE KEY B C EXISTING WALL TO REMAIN PATCH AND PAINT AS REQUIRED FOR UNIFORM FINISH D FULL HGT TO UNDERSIDE OF T -BAR CEILING - 5/8" GWB 2X4 STUDS @16 "O.C. 5/8" GWB FULL HGT TO UNDERSIDE OF ROOF STRUCTURE - 5/8" GWB 2X4 STUDS @16 "O.C. 5/8" GWB ROOM FINISH SCHEDULE NO. ROOM WALLS NORTH SOUTH EAST WEST FLOOR CEILING BASE NOTES 100 LOBBY P 1 P 2 P 1 P 1 C1 /C4 EXIST. ACT 101 CONFERENCE P 1 P 1 P 1 P 4 C1 EXIST. ACT 102 OPEN OFFICE P 3 P 2 P 1 P4 C1 EXIST. ACT 103 OFFICE P 1 P 1 P 1 P4 C1 EXIST. ACT 104 OFFICE P 1 P 1 P 1 P 4 C1 EXIST. ACT 105 OFFICE P 1 P 1 P 1 P 1 C1 EXIST. ACT FURRING @ EXTERIOR WALL (CONCEAL OVERHEAD DOOR) - 2 X TREATED STUDS @ 24" O.C. FILL ALL STUD CAVITIES WITH FACED INSULATION BA 5/8" GWB 4 L N Eve ' AL-1 5 1°ARA r Nevi Rgiah2 lgoAi Io 4 - i{E,TEP To fae a/07.7) wti14 f 41i f. tz-0'1 It. SUL 11' -9" 106 107 108 109 110 STORAGE BREAK ROOM HALL TOILET TOILET (ACCESSIBLE) PAINT KEY: P 1 P 1 P 4 P 1 P 1 P 1 P 1 P 4 P 1 P 1 P1 - GLIDDEN / ICI #A1822 DESERT CASTLE PRIMER - 1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH P2 GLIDDEN / ICI #A0574 OAKLEY BROWN PRIMER - 1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 (TINTED) FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH P 1 P 1 P 1 P 1 P 1 P 1 P4 P4 P 4 NIC NIC C1 EXIST. EXIST. EXIST. ACT EXIST. ACT EXIST. ACT EXIST. GWB EXIST. GWB P3 - GLIDDEN / ICI #A1048 BLADE PRIMER - 1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH P4 - GLIDDEN / ICI #A1964 SHADOW PLAY PRIMER - 1 COAT GLIDDEN HIGH -HIDE PRIMER 1000 -1200 (TINTED) FINISH - 2 COATS FINISH PAINT IN GLIDDEN ULTRAHIDE 250, 1420N SERIES EGSHELL FINISH FLOORING KEY: C1 - INTERFACE FLOR 1465202500 TO SCALE COLOR #7769 FOUNDATION * *CARPET TILES TO BE INSTALLED IN RANDOM PATTERN ** C4 - INTERFACE ENTRY TILE 129017191 COLOR #7191 OLIVE T1 - JOHNSONITE: VCTAZ -V603 BUFF CORTINA COLORS - AZROCK SUPPLIED BY H &R BLOCK (WHERE SHEET VINYL REQ'D. BY CODE, USE JOHNSONITE MELODIA - #620 BEACHFRONT) UNISEX TOILET DEMO EXISTING WALL - RELOC. TELEPHONE BD. TO NEW WALL EXISTING ELECTRICAL PANEL (TO REMAIN: 36' -0" EXISTING (FIELD VERIFY) EXISTING OVERHEAD DOOR AND TRACK ^O REMAIN IN PLACE HALL 108 9 MIr.e M/4a #. ./ / /M,, STORAGE F-311061 0 OFFICE 105 111 OFFICE 104 th OFFICE 103 o OPEN OFFICE 102 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2012 City of Tukwila BUILDING DIVISION o CONFERENCE 101 LOBBY 100 e 10' -8" 15'-4" 63' -4" EXISTING (FIELD VERIFY) 12' -0" FLOOR PLAN SCALE: 1/4" -1' -0" 1 23' -2" EXISTING (FIELD VERIFY S3O RtUttvto CITY OF TUKWILA OCT 0t2012 PERMIT CENTER REF. NORTH L -, J O O co z 0 Z w u. z W 0 2 Ln z 0 0 0 1- z 0 1- 0 J z m J } (r) z < I - c N O e U Z O to U ¢ Z VIO�N co CO CO Ln N LO -- H. j V � J O J W w 0a U_ Q LL ozj LL o = O� INTERIOR TENANT IMPROVEMENT w L) t0 N z w Q 0 z J 0 E 0 wJ nLL DRAWN BY: GBB CHECKED BY: JOB #: PHASE: DATE: 9/5/12 SHEET #: A2.0 L J of l PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING REMARKS PERMIT SUE 1 1 1 1 N 4.l , 1 1 DRAWN BY: GBB CHECKED BY: JOB #: PHASE: DATE: 9/5/12 SHEET #: A2.0 L J GENERAL NOTES: 1. SUSPENDED CEILING GRID SYSTEM TO REMAIN; RELOCATE LIGHT FIXTURES AS SHOWN; REPLACE BROKEN OR STAINED CEILING TILES FOR CLEAN, UNIFORM APPEARANCE, TYPICAL THROUGHOUT. GWB CEILINGS, SPRINKLER HEADS AND HVAC SUPPLY/ RETURN TO REMAIN, ANY MODIFICATIONS REQUIRED TO SUIT NEW OFFICE LAYOUT WILL BE BIDDER - DESIGNED AND ANY REQUIRED PERMITTING TO BE BY MECHANCIAL SUBCONTRACTOR. 2. CLEAN ALL HVAC GRILLSNENTS 3. PROJECT TO BE ELECTRICAL AND MECHANICAL DESIGN - BUILD. LIGHTING SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. IBC 1006.1 - ILLUMINATION REQUIREMENTS 1. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. B. IBC 1006.2 - ILLUMINATION LEVEL 1. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT - CANDLE (11 LUX) AT THE FLOOR LEVEL. C. IBC 1006.3 - ILLUMINATION EMERGENCY POWER 1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISE'S ELECTRIC SUPPLY. 1.1. LOCATIONS INCLUDE: DEDICATED EGRESS ROUTES IN LARGER ROOMS OR SPACES, PUBLIC OR COMMON EGRESS ELEMENTS, ESSENTIAL PORTIONS OF THE INTERIOR EGRESS SYSTEM, INTERIOR EXIST DISCHARGE ELEMENTS, AND EXTERIOR PORTIONS OF THE EXIT DISCHARGE. D. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF WSEC 1513 INCLUDING BUT NOT LIMITED TO LOCAL CONTROL, ACCESSIBILITY AND DAY LIGHTING. 4. HVAC SOLUTION SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. VENTILATION REQUIREMENTS FOR RESTROOMS PER WASHINGTON STATE MECHANICAL CODE (WAC 51 -52) B. ALL OCCUPIED SPACES SHALL BE VENTILATED BY MECHANICAL MEANS IN ACCORDANCE WITH SECTION 403 IN THE 2009 INTERNATIONAL MECHANICAL CODE. THE VENTILATION SYSTEM SERVING THE SPACE SHALL BE DESIGNED TO PROVIDE VENTILATION OVER AND ABOVE THAT REQUIRED BY TABLE 403.3 IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE. 5. EXIT SIGNAGE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: A. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS MINIMUM OF SIX INCHES HIGH AND SHALL CONFORM WITH ALL APPLICABLE CODES. 6. THE BUILDING IS FULLY SPRINKLERED. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE FIRE PROTECTION DRAWINGS AS REQUIRED BY THE GOVERNING AUTHORITY. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO COMMENCING WITH THE WORK. LEGEND: E/R INTERNALLY LIGHTED EXIT SIGNAGE W/ BATTERY BACKUP PER IBC SECTION 1011, CONFIRM OPERATION FOR EXISTING. ADD WHERE NOT EXISTING. NEW 2X4 LAY -IN FLUORESCENT LIGHT, IC RATED, 18 CELL PARABOLIC, (2) T -5 LAMPS PER FIXTURE EXISTING SUSPENDED CEILING GRID TO REMAIN EXISTING RELOCATED LIGHT FIXTURE — — — J EI L 1 C -- J EIR E/R REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2012 City of Tukwila BUILDING DIVISION E/R cp tb E/R 1•' EIR c i� EIR EIR Q ql) hp REFLECTED CEILING PLAN b RECEIVED CITY OF TUK'vVILA SEP 0 7 2012 PERMIT CENTER REF. NORTH L 1 0 ■ L) O co 0 Ln Lf'1 0 co Q1 z 0 z W 0 O 0 1- z O H J 0 z m ce co co oo (^^ M O J W M W W z .,/ LL H I0 INTERIOR TENANT IMPROVEMENT AN INTERIOR TENANT IMPROVMENT TO AN EXISTING 2,165 S.F. SPACE IADATE REMARKS BY I - -- / - - / -- PERMIT SUBMITTAL - 1 1 1 ; 4 1 I PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING DRAWN BY: GBB CHECKED BY: JOB #: PHASE: DATE: 9/5/12 SHEET #: A3.0 J